1
|
Duan X, Li N, Cooper DML, Ding XF, Chen X, Zhu N. Low-density tissue scaffold imaging by synchrotron radiation propagation-based imaging computed tomography with helical acquisition mode. J Synchrotron Radiat 2023; 30:417-429. [PMID: 36891855 PMCID: PMC10000810 DOI: 10.1107/s1600577523000772] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Accepted: 01/29/2023] [Indexed: 06/18/2023]
Abstract
Visualization of low-density tissue scaffolds made from hydrogels is important yet challenging in tissue engineering and regenerative medicine (TERM). For this, synchrotron radiation propagation-based imaging computed tomography (SR-PBI-CT) has great potential, but is limited due to the ring artifacts commonly observed in SR-PBI-CT images. To address this issue, this study focuses on the integration of SR-PBI-CT and helical acquisition mode (i.e. SR-PBI-HCT) to visualize hydrogel scaffolds. The influence of key imaging parameters on the image quality of hydrogel scaffolds was investigated, including the helical pitch (p), photon energy (E) and the number of acquisition projections per rotation/revolution (Np), and, on this basis, those parameters were optimized to improve image quality and to reduce noise level and artifacts. The results illustrate that SR-PBI-HCT imaging shows impressive advantages in avoiding ring artifacts with p = 1.5, E = 30 keV and Np = 500 for the visualization of hydrogel scaffolds in vitro. Furthermore, the results also demonstrate that hydrogel scaffolds can be visualized using SR-PBI-HCT with good contrast while at a low radiation dose, i.e. 342 mGy (voxel size of 26 µm, suitable for in vivo imaging). This paper presents a systematic study on hydrogel scaffold imaging using SR-PBI-HCT and the results reveal that SR-PBI-HCT is a powerful tool for visualizing and characterizing low-density scaffolds with a high image quality in vitro. This work represents a significant advance toward the non-invasive in vivo visualization and characterization of hydrogel scaffolds at a suitable radiation dose.
Collapse
Affiliation(s)
- Xiaoman Duan
- Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| | - Naitao Li
- Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| | - David M. L. Cooper
- Department of Anatomy, Physiology and Pharmacology, College of Medicine, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| | - Xiao Fan Ding
- Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| | - Xiongbiao Chen
- Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
- Department of Mechanical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| | - Ning Zhu
- Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
- Department of Chemical and Biological Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
- Canadian Light Source, Saskatoon, SK S7N 2V3, Canada
| |
Collapse
|
2
|
Twengström W, Moro CF, Romell J, Larsson JC, Sparrelid E, Björnstedt M, Hertz HM. Can laboratory x-ray virtual histology provide intraoperative 3D tumor resection margin assessment? J Med Imaging (Bellingham) 2022; 9:031503. [PMID: 35155718 PMCID: PMC8820384 DOI: 10.1117/1.jmi.9.3.031503] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Accepted: 12/21/2021] [Indexed: 11/14/2022] Open
Abstract
Purpose: Surgery is an essential part of the curative plan for most patients affected with solid tumors. The outcome of such surgery, e.g., recurrence rates and ultimately patient survival, depends on several factors where the resection margin is of key importance. Presently, the resection margin is assessed by classical histology, which is time-consuming (several days), destructive, and basically only gives two-dimensional information. Clearly, it would be advantageous if immediate feedback on tumor extension in all three dimensions were available to the surgeon intraoperatively. Approach: We investigate a laboratory propagation-based phase-contrast x-ray computed tomography system that provides the resolution, the contrast, and, potentially, the speed for this purpose. The system relies on a liquid-metal jet microfocus source and a scintillator-coated CMOS detector. Our study is performed on paraffin-embedded non-stained samples of human pancreatic neuroendocrine tumors, liver intrahepatic cholangiocarcinoma, and pancreatic serous cystic neoplasm (benign). Results: We observe tumors with distinct and sharp edges having cellular resolution ( ∼ 10 μ m ) as well as many assisting histological landmarks, allowing for resection margin assessment. All x-ray data are compared with classical histology. The agreement is excellent. Conclusion: We conclude that the method has potential for intraoperative three-dimensional virtual histology.
Collapse
Affiliation(s)
- William Twengström
- KTH/Albanova, Department of Applied Physics, Stockholm, Sweden,Address all correspondence to William Twengström, ; Carlos Fernández Moro, ; Hans M. Hertz,
| | - Carlos F. Moro
- Karolinska University Hospital, Department of Clinical Pathology and Cancer Diagnostics, Stockholm, Sweden,Karolinska University Hospital Huddinge, Karolinska Institutet, Division of Pathology F46, Department of Laboratory Medicine, Stockholm, Sweden,Address all correspondence to William Twengström, ; Carlos Fernández Moro, ; Hans M. Hertz,
| | - Jenny Romell
- KTH/Albanova, Department of Applied Physics, Stockholm, Sweden
| | | | - Ernesto Sparrelid
- Karolinska Institutet, Division of Surgery, Department of Clinical Science, Intervention and Technology, Stockholm, Sweden
| | - Mikael Björnstedt
- Karolinska University Hospital, Department of Clinical Pathology and Cancer Diagnostics, Stockholm, Sweden,Karolinska University Hospital Huddinge, Karolinska Institutet, Division of Pathology F46, Department of Laboratory Medicine, Stockholm, Sweden
| | - Hans M. Hertz
- KTH/Albanova, Department of Applied Physics, Stockholm, Sweden,Address all correspondence to William Twengström, ; Carlos Fernández Moro, ; Hans M. Hertz,
| |
Collapse
|
3
|
Ning L, Zhu N, Smith A, Rajaram A, Hou H, Srinivasan S, Mohabatpour F, He L, Mclnnes A, Serpooshan V, Papagerakis P, Chen X. Noninvasive Three-Dimensional In Situ and In Vivo Characterization of Bioprinted Hydrogel Scaffolds Using the X-ray Propagation-Based Imaging Technique. ACS Appl Mater Interfaces 2021; 13:25611-25623. [PMID: 34038086 DOI: 10.1021/acsami.1c02297] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Hydrogel-based three-dimensional (3D) bioprinting has been illustrated as promising to fabricate tissue scaffolds for regenerative medicine. Notably, bioprinting of hydrated and soft 3D hydrogel scaffolds with desired structural properties has not been fully achieved so far. Moreover, due to the limitations of current imaging techniques, assessment of bioprinted hydrogel scaffolds is still challenging, yet still essential for scaffold design, fabrication, and longitudinal studies. This paper presents our study on the bioprinting of hydrogel scaffolds and on the development of a novel noninvasive imaging method, based on synchrotron propagation-based imaging with computed tomography (SR-PBI-CT), to study the structural properties of hydrogel scaffolds and their responses to environmental stimuli both in situ and in vivo. Hydrogel scaffolds designed with varying structural patterns were successfully bioprinted through rigorous printing process regulations and then imaged by SR-PBI-CT within physiological environments. Subjective to controllable compressive loadings, the structural responses of scaffolds were visualized and characterized in terms of the structural deformation caused by the compressive loadings. Hydrogel scaffolds were later implanted in rats as nerve conduits for SR-PBI-CT imaging, and the obtained images illustrated their high phase contrast and were further processed for the 3D structure reconstruction and quantitative characterization. Our results show that the scaffold design and printing conditions play important roles in the printed scaffold structure and mechanical properties. More importantly, our obtained images from SR-PBI-CT allow us to visualize the details of hydrogel 3D structures with high imaging resolution. It demonstrates unique capability of this imaging technique for noninvasive, in situ characterization of 3D hydrogel structures pre- and post-implantation in diverse physiological milieus. The established imaging platform can therefore be utilized as a robust, high-precision tool for the design and longitudinal studies of hydrogel scaffold in tissue engineering.
Collapse
Affiliation(s)
- Liqun Ning
- Department of Mechanical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
- Department of Biomedical Engineering, Emory University School of Medicine and Georgia Institute of Technology, Atlanta, Georgia 30322, United States
| | - Ning Zhu
- Canadian Light Source, Saskatoon, SK S7N 2V3, Canada
- Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
- Department of Chemical and Biological Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| | - An Smith
- Department of Biology, College of Arts and Science, University of Saskatchewan, Saskatoon, SK S7N 5E2, Canada
| | - Ajay Rajaram
- Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| | - Huishu Hou
- Department of Surgery, Division of Neurosurgery, College of Medicine, University of Saskatchewan, Saskatoon, SK S7N 5E5, Canada
| | - Subashree Srinivasan
- Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| | - Fatemeh Mohabatpour
- Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| | - Lihong He
- Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
- Department of Cell Biology, Medical College of Soochow University, Suzhou 215123, China
| | - Adam Mclnnes
- Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| | - Vahid Serpooshan
- Department of Biomedical Engineering, Emory University School of Medicine and Georgia Institute of Technology, Atlanta, Georgia 30322, United States
- Department of Pediatrics, Emory University School of Medicine, Atlanta, Georgia 30322, United States
- Children's Healthcare of Atlanta, Atlanta, Georgia 30322, United States
| | - Petros Papagerakis
- College of Dentistry, University of Saskatchewan, Saskatoon, SK S7N 5E4, Canada
| | - Xiongbiao Chen
- Department of Mechanical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
- Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK S7N 5A9, Canada
| |
Collapse
|