1
|
McNeil JC, Sommer LM, Vallejo JG, Hulten KG, Kaplan SL. Association of qacA/B and smr Carriage with Staphylococcus aureus Survival following Exposure to Antiseptics in an Ex Vivo Venous Catheter Disinfection Model. Microbiol Spectr 2023; 11:e0333322. [PMID: 36862001 PMCID: PMC10100659 DOI: 10.1128/spectrum.03333-22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Accepted: 02/01/2023] [Indexed: 03/03/2023] Open
Abstract
Many health care centers have reported an association between Staphylococcus aureus isolates bearing efflux pump genes and an elevated MIC/minimal bactericidal concentration (MBC) to chlorhexidine gluconate (CHG) and other antiseptics. The significance of these organisms is uncertain, given that their MIC/MBC is typically far lower than the CHG concentration in most commercial preparations. We sought to evaluate the relationship between carriage of the efflux pump genes qacA/B and smr in S. aureus and the efficacy of CHG-based antisepsis in a venous catheter disinfection model. S. aureus isolates with and without smr and/or qacA/B were utilized. The CHG MICs were determined. Venous catheter hubs were inoculated and exposed to CHG, isopropanol, and CHG-isopropanol combinations. The microbiocidal effect was calculated as the percent reduction in CFU following exposure to the antiseptic relative to the control. The qacA/B- and smr-positive isolates had modest elevations in the CHG MIC90 compared to the qacA/B- and smr-negative isolates (0.125 mcg/ml vs. 0.06 mcg/ml, respectively). However, the CHG microbiocidal effect was significantly lower for qacA/B- and/or smr-positive strains than for susceptible isolates, even when the isolates were exposed to CHG concentrations up to 400 μg/mL (0.04%); this finding was most notable for isolates bearing both qacA/B and smr (89.3% versus 99.9% for the qacA/B- and smr-negative isolates; P = 0.04). Reductions in the median microbiocidal effect were also observed when these qacA/B- and smr-positive isolates were exposed to a solution of 400 μg/mL (0.04%) CHG and 70% isopropanol (89.5% versus 100% for the qacA/B- and smr-negative isolates; P = 0.002). qacA/B- and smr-positive S. aureus isolates have a survival advantage in the presence of CHG concentrations exceeding the MIC. These data suggest that traditional MIC/MBC testing may underestimate the ability of these organisms to resist the effects of CHG. IMPORTANCE Antiseptic agents, including chlorhexidine gluconate (CHG), are commonly utilized in the health care environment to reduce rates of health care-associated infections. A number of efflux pump genes, including smr and qacA/B, have been reported in Staphylococcus aureus isolates that are associated with higher MICs and minimum bactericidal concentrations (MBCs) to CHG. Several health care centers have reported an increase in the prevalence of these S. aureus strains following an escalation of CHG use in the hospital environment. The clinical significance of these organisms, however, is uncertain, given that the CHG MIC/MBC is far below the concentration in commercial preparations. We present the results of a novel surface disinfection assay utilizing venous catheter hubs. We found that qacA/B-positive and smr-positive S. aureus isolates resist killing by CHG at concentrations far exceeding the MIC/MBC in our model. These findings highlight that traditional MIC/MBC testing is insufficient to evaluate susceptibility to antimicrobials acting on medical devices.
Collapse
Affiliation(s)
- J. Chase McNeil
- Department of Pediatrics, Division of Infectious Diseases, Baylor College of Medicine, Houston, Texas, USA
- Texas Children’s Hospital, Houston, Texas, USA
| | - Lauren M. Sommer
- Department of Pediatrics, Division of Infectious Diseases, Baylor College of Medicine, Houston, Texas, USA
- Texas Children’s Hospital, Houston, Texas, USA
| | - Jesus G. Vallejo
- Department of Pediatrics, Division of Infectious Diseases, Baylor College of Medicine, Houston, Texas, USA
- Texas Children’s Hospital, Houston, Texas, USA
| | - Kristina G. Hulten
- Department of Pediatrics, Division of Infectious Diseases, Baylor College of Medicine, Houston, Texas, USA
- Texas Children’s Hospital, Houston, Texas, USA
| | - Sheldon L. Kaplan
- Department of Pediatrics, Division of Infectious Diseases, Baylor College of Medicine, Houston, Texas, USA
- Texas Children’s Hospital, Houston, Texas, USA
| |
Collapse
|
2
|
Zhang C, Liang B, Xiong Z, Liang Z, Cai H, Zhong H, Xie Y, Xie Y, Liu X, Xie S, Lan F, Zhou Z. Distribution of Biocide Resistance Genes and Association with Clonal Complex Genotypes in Staphylococcus aureus Isolated from School-Age Children in Guangzhou. Infect Drug Resist 2022; 15:7165-7175. [PMID: 36514798 PMCID: PMC9741823 DOI: 10.2147/idr.s387528] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Accepted: 11/26/2022] [Indexed: 12/12/2022] Open
Abstract
Purpose Chlorhexidine and mupirocin are often prescribed to children in affected communities to prevent colonization and transmission of Staphylococcus aureus, but this has led to an increasing rate of biocide resistance. In this study, we aimed to determine the distribution of biocide resistance genes among S. aureus isolates from school-age children in Guangzhou, investigate chlorhexidine gluconate and mupirocin susceptibility and clonal complex (CC) genotypes in strains carrying biocide-resistance genes, and further explore the role of biofilms in this resistance. Patients and Methods Antibiotic resistance and multilocus sequence genotyping were performed on 722 S. aureus isolates from previous study. The distribution of nine biocide genes (qacA/B, mupA, mepA, sepA, norA, lmrS, smr, mupB, qacG) was determined by PCR. Isolates carrying qacA/B or mupA genes were further tested for susceptibility to chlorhexidine gluconate (CHG) and mupirocin and biofilm formation abilities. Results The most prevalent of the nine biocide resistance genes were mepA (95.57%), followed by norA (78.81%), lmrS (77.01%), and sepA (58.17%). The qacG gene was not detected. Distribution of sepA was significantly decreased in CC30 and CC45 genotypes, and presence of sepA was associated with resistance to antibiotics such as CLI, ERY, TCY, SXT, CIP, and LVX. In addition, 64 (94.1%, n=68) qacA/B+ isolates showed CHG resistance, 12 (100.0%, n=12) mupA+ isolates were mupirocin resistant, and 4 (80%, n=5) and 5 (100%, n=5) qacA/B+mupA+ isolates were CHG and mupirocin resistant, respectively. Of these 85 isolates, 98.8% (n=84) had different degrees of biofilm-forming abilities, which were positively associated with CHG and mupirocin resistance. Conclusion The distribution of biocide resistance genes was associated with special CCs. The qacA/B and mupA genes are highly associated with resistance to CHG and mupirocin, and biofilm formation was found to contribute to this biocide resistance.
Collapse
Affiliation(s)
- Chao Zhang
- Clinical Laboratory, Guangzhou Women and Children’s Medical Center, Guangzhou Medical University, Guangzhou, Guangdong, People’s Republic of China,Clinical Laboratory, Longgang District Maternity and Child Healthcare Hospital, Shenzhen, Guangdong, People’s Republic of China
| | - Bingshao Liang
- Clinical Laboratory, Guangzhou Women and Children’s Medical Center, Guangzhou Medical University, Guangzhou, Guangdong, People’s Republic of China
| | - Zhile Xiong
- Clinical Laboratory, Guangzhou Women and Children’s Medical Center, Guangzhou Medical University, Guangzhou, Guangdong, People’s Republic of China,Clinical Laboratory, Longgang District Maternity and Child Healthcare Hospital, Shenzhen, Guangdong, People’s Republic of China
| | - Zhuwei Liang
- Clinical Laboratory, Guangzhou Women and Children’s Medical Center, Guangzhou Medical University, Guangzhou, Guangdong, People’s Republic of China,Clinical Laboratory, Longgang District Maternity and Child Healthcare Hospital, Shenzhen, Guangdong, People’s Republic of China
| | - Hao Cai
- Clinical Laboratory, Guangzhou Women and Children’s Medical Center, Guangzhou Medical University, Guangzhou, Guangdong, People’s Republic of China
| | - Huamin Zhong
- Clinical Laboratory, Guangzhou Women and Children’s Medical Center, Guangzhou Medical University, Guangzhou, Guangdong, People’s Republic of China
| | - Yongqiang Xie
- Clinical Laboratory, Guangzhou Women and Children’s Medical Center, Guangzhou Medical University, Guangzhou, Guangdong, People’s Republic of China
| | - Yuanwei Xie
- Clinical Laboratory, Longgang District Maternity and Child Healthcare Hospital, Shenzhen, Guangdong, People’s Republic of China
| | - Xiaochun Liu
- Clinical Laboratory, Longgang District Maternity and Child Healthcare Hospital, Shenzhen, Guangdong, People’s Republic of China
| | - Shiying Xie
- Clinical Laboratory, Longgang District Maternity and Child Healthcare Hospital, Shenzhen, Guangdong, People’s Republic of China
| | - Fangjun Lan
- Clinical Laboratory, Longgang District Maternity and Child Healthcare Hospital, Shenzhen, Guangdong, People’s Republic of China
| | - Zhenwen Zhou
- Clinical Laboratory, Longgang District Maternity and Child Healthcare Hospital, Shenzhen, Guangdong, People’s Republic of China,Correspondence: Zhenwen Zhou, Clinical Laboratory, Longgang District Maternity and Child Healthcare Hospital, Shenzhen, Guangdong, People’s Republic of China, Tel +86 13925097897, Email
| |
Collapse
|
3
|
Addetia A, Greninger AL, Adler A, Yuan S, Makhsous N, Qin X, Zerr DM. A Novel, Widespread qacA Allele Results in Reduced Chlorhexidine Susceptibility in Staphylococcus epidermidis. Antimicrob Agents Chemother 2019; 63:e02607-18. [PMID: 30988144 DOI: 10.1128/AAC.02607-18] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2018] [Accepted: 03/13/2019] [Indexed: 12/12/2022] Open
Abstract
Chlorhexidine gluconate (CHG) is a topical antiseptic widely used in health care settings. In Staphylococcus spp., the pump QacA effluxes CHG, while the closely related QacB cannot due to a single amino acid substitution. We characterized 1,050 cutaneous Staphylococcus isolates obtained from 173 pediatric oncology patients enrolled in a multicenter CHG bathing trial. CHG susceptibility testing revealed that 63 (6%) of these isolates had elevated CHG MICs (≥4 μg/ml). Screening of all 1,050 isolates for the qacA/B gene (the same qac gene with A or B allele) by restriction fragment length polymorphism (RFLP) yielded 56 isolates with a novel qacA/B RFLP pattern, qacA/B273 The CHG MIC was significantly higher for qacA/B273 -positive isolates (MIC50, 4 μg/ml; MIC range, 0.5 to 4 μg/ml) than for other qac groups: qacA-positive isolates (n = 559; MIC50, 1 μg/ml; MIC range, 0.5 to 4 μg/ml), qacB-positive isolates (n = 17; MIC50, 1 μg/ml; MIC range, 0.25 to 2 μg/ml), and qacA/B-negative isolates (n = 418, MIC50, 1 μg/ml; MIC range, 0.125 to 2 μg/ml) (P = 0.001). A high proportion of the qacA/B273 -positive isolates also displayed methicillin resistance (96.4%) compared to the other qac groups (24.9 to 61.7%) (P = 0.001). Whole-genome sequencing revealed that qacA/B273 -positive isolates encoded a variant of QacA with 2 amino acid substitutions. This new allele, named qacA4, was carried on the novel plasmid pAQZ1. The qacA4-carrying isolates belonged to the highly resistant Staphylococcus epidermidis sequence type 2 clone. By searching available sequence data sets, we identified 39 additional qacA4-carrying S. epidermidis strains from 5 countries. Curing an isolate of qacA4 resulted in a 4-fold decrease in the CHG MIC, confirming the role of qacA4 in the elevated CHG MIC. Our results highlight the importance of further studying qacA4 and its functional role in clinical staphylococci.
Collapse
|
4
|
Chan MKL, Koo SH, Quek Q, Pang WS, Jiang B, Ng LSY, Tan SH, Tan TY. Development of a real-time assay to determine the frequency of qac genes in methicillin resistant Staphylococcus aureus. J Microbiol Methods 2018; 153:133-138. [PMID: 30267717 DOI: 10.1016/j.mimet.2018.09.017] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2018] [Revised: 09/24/2018] [Accepted: 09/25/2018] [Indexed: 10/28/2022]
Abstract
PURPOSE The emergence of antiseptic resistance and/or antiseptic-resistance genes in methicillin-resistant Staphylococcus aureus (MRSA) may result in failure of decolonization treatments. Plasmid-encoded efflux pump genes qacA/B and qacC (smr) confer tolerance to chlorhexidine and quaternary ammonium compounds. The objective of this study was to develop and validate a multiplex real time-PCR assay for detection of antiseptic-resistance genes, apply the assay on 200 MRSA isolates and explore if carriage of these genes was associated with resistance to topical antibiotics. METHODOLOGY A SYBR-Green based multiplex real time-PCR assay was developed to detect qacA/B, qacC, and mecA (internal control) simultaneously. The multiplex assay was compared against conventional single-plex PCR followed by agarose gel electrophoresis, using DNA from the first 73 MRSA isolates, followed by multiplex testing of the remaining 127 MRSA isolates. All 200 MRSA isolates were tested for susceptibility to mupirocin, retapamulin, neomycin, bacitracin and octenidine. The genetic diversity of the isolates was investigated by spa-typing. RESULTS The concordance between multiplex and conventional PCR, in assignments of qacA/B and qacC status were 99%(72/73) and 100%(73/73) respectively. Among 200 MRSA isolates, 48(24%) and 44(23%) were found to harbour qacA/B and qacC genes, respectively. These isolates remained susceptible to many common decolonization agents, except mupirocin. The predominant spa-types were t020 and t1081 (41 and 32 isolates respectively). CONCLUSION The real-time assay performed acceptably for the detection of qac genes. A high prevalence of antiseptic-resistance genes were detected in the MRSA isolates in our population and appeared to be associated with spa-type t1081.
Collapse
Affiliation(s)
- Maurice Kok Leong Chan
- Department of Laboratory Medicine, Changi General Hospital, 2 Simei Street 3, 529889, Singapore
| | - Seok Hwee Koo
- Clinical trials and Research Unit, Changi General Hospital, 2 Simei Street 3, 529889, Singapore
| | - Qingyao Quek
- School of Life Sciences and Chemical Technology, Ngee Ann Polytechnic, 535 Clementi Road, 599489, Singapore
| | - Wan Sia Pang
- School of Life Sciences and Chemical Technology, Ngee Ann Polytechnic, 535 Clementi Road, 599489, Singapore
| | - Boran Jiang
- Department of Laboratory Medicine, Changi General Hospital, 2 Simei Street 3, 529889, Singapore
| | - Lily Siew Yong Ng
- Department of Laboratory Medicine, Changi General Hospital, 2 Simei Street 3, 529889, Singapore
| | - Si Huei Tan
- Department of Laboratory Medicine, Changi General Hospital, 2 Simei Street 3, 529889, Singapore
| | - Thean Yen Tan
- Department of Laboratory Medicine, Changi General Hospital, 2 Simei Street 3, 529889, Singapore.
| |
Collapse
|
5
|
Kong H, Fang L, Jiang R, Tong J. Distribution of sasX, pvl, and qacA/B genes in epidemic methicillin-resistant Staphylococcus aureus strains isolated from East China. Infect Drug Resist 2018; 11:55-59. [PMID: 29386909 PMCID: PMC5765971 DOI: 10.2147/idr.s153399] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Background Methicillin-resistant Staphylococcus aureus (MRSA) is a major nosocomial pathogen. Various virulence and antiseptic-resistant factors increase the pathogenicity of MRSA strains and allow for increased infection rates. Purpose The purpose of this study was to investigate the prevalence and distribution of virulence-associated and antiseptic-resistant genes from epidemic MRSA strains isolated from East China. Methods A newly designed multiplex PCR assay was used to assess whether the virulence-associated genes sasX and pvl and the chlorhexidine tolerance gene qacA/B were present in 189 clinical isolates of MRSA. Multilocus sequence typing (MLST) and Staphylococcal protein A (spa) typing of these isolates were also performed. The frequency of these genes in isolates with epidemic sequence types (STs) was investigated. Results Twenty STs and 36 spa types with five epidemic clones (ST5-t311, ST59-t437, ST5-t002, ST239-t030, and ST239-t037) were identified. The prevalence of sasX, pvl, and qacA/B in all isolates was 5.8%, 10.1%, and 20.1%, respectively. The prevalences of these genes in isolates with ST5, ST59, ST239, and other ST genetic backgrounds were all significantly different (P<0.001). Isolates that had the highest frequency of sasX, pvl, or qacA/B were ST239 (33.3%), ST59 (28.9%), and ST5 (34.1%), respectively. The gene distribution pattern from all of the isolates showed that sasX−pvl−qacA/B+, sasX−pvl+qacA/B−, and sasX+pvl−qacA/B− were closely associated with epidemic clones ST5-t311, ST59-t437, and ST239-t037, respectively. Conclusion There are significant differences in the prevalence of virulence-associated and antiseptic-resistant genes in epidemic MRSA strains. Using this information, more effective control and prevention strategies for nosocomial MRSA infections can be developed.
Collapse
Affiliation(s)
- Haishen Kong
- State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, China.,Key Laboratory of Clinical In Vitro Diagnostic Techniques of Zhejiang Province, Department of Laboratory Medicine, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, China
| | - Lingmei Fang
- Clinical Laboratory, Chunan First People's Hospital, Zhejiang Province People's Hospital Chunan Branch, Hangzhou, China
| | - Rujin Jiang
- Clinical Laboratory, Yuhang Hospital of Traditional Chinese Medicine, Hangzhou, China
| | - Jixiang Tong
- Key Laboratory of Clinical In Vitro Diagnostic Techniques of Zhejiang Province, Department of Laboratory Medicine, First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou, China
| |
Collapse
|
6
|
McNeil JC, Hultén KG, Mason EO, Kaplan SL. Impact of Health Care Exposure on Genotypic Antiseptic Tolerance in Staphylococcus aureus Infections in a Pediatric Population. Antimicrob Agents Chemother 2017; 61:e00223-17. [PMID: 28438928 DOI: 10.1128/AAC.00223-17] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2017] [Accepted: 04/15/2017] [Indexed: 12/31/2022] Open
Abstract
Staphylococcus aureus possessing either the smr gene or the qacA/B genes is associated with decreased susceptibility to chlorhexidine gluconate (CHG) and other antiseptics. Previous studies of antiseptic-tolerant staphylococci have focused largely on high-risk populations, and the exact role of health care exposure in the acquisition of these organisms is unclear. We sought to describe the risk factors and features of infection caused by antiseptic-tolerant S. aureus in a general pediatric population. Isolates were selected from an ongoing S. aureus surveillance study. Every third sequential isolate in the year 2014 was selected for inclusion. All isolates underwent PCR for the genes qacA/B and smr Medical records were reviewed. Five hundred six isolates were included in the study, with 377 (74.3%) being community acquired. One hundred (19.8%) isolates were smr positive and 79 (15.6%) qacA/B positive. In univariable analyses, the presence of either gene was associated with underlying medical conditions, nosocomial acquisition, recent hospitalization, central venous lines, and CHG exposure. In multivariable analyses, only differences between patients with chronic medical conditions (odds ratio [OR] = 1.72; 95% confidence interval [CI], 1.22 to 2.64) and nosocomial acquisition (OR = 2.48; 95% CI, 1.16 to 8.17) remained statistically significant. Among patients without risk factors, 27.9% had infection with an antiseptic-tolerant isolate. smr- or qacA/B-positive S. aureus isolates are common in children and are independently associated with nosocomial acquisition and underlying medical conditions. These findings imply a role for the health care environment in acquisition of these organisms. However, genotypic antiseptic tolerance was seen in >25% of healthy children with an S. aureus infection, indicating that these organism are prevalent in the community as well.
Collapse
|
7
|
Rondeau C, Chevet G, Blanc DS, Gbaguidi-Haore H, Decalonne M, Dos Santos S, Quentin R, van der Mee-Marquet N. Current Molecular Epidemiology of Methicillin-Resistant Staphylococcus aureus in Elderly French People: Troublesome Clones on the Horizon. Front Microbiol 2016; 7:31. [PMID: 26858707 PMCID: PMC4729942 DOI: 10.3389/fmicb.2016.00031] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2015] [Accepted: 01/11/2016] [Indexed: 11/13/2022] Open
Abstract
Objective: In 2015, we conducted at 44 healthcare facilities (HCFs) and 21 nursing homes (NHs) a 3-month bloodstream infection (BSI) survey, and a 1-day prevalence study to determine the rate of carriage of methicillin-resistant Staphylococcus aureus (MRSA) in 891 patients and 470 residents. We investigated the molecular characteristics of the BSI-associated and colonizing MRSA isolates, and assessed cross-transmission using double-locus sequence typing and pulsed-field gel electrophoresis protocol. Results: The incidence of MRSA-BSI was 0.040/1000 patient-days (19 cases). The prevalence of MRSA carriage was 4.2% in patients (n = 39) and 8.7% in residents (n = 41) (p < 0.001). BSI-associated and colonizing isolates were similar: none were PVL-positive; 86.9% belonged to clonal complexes 5 and 8; 93.9% were resistant to fluoroquinolones. The qacA/B gene was carried by 15.8% of the BSI-associated isolates [3/3 BSI cases in intensive care units (ICUs)], and 7.7% of the colonizing isolates in HCFs. Probable resident-to-resident transmission was identified in four NHs. Conclusion: Despite generally reassuring results, we identified two key concerns. First, a worryingly high prevalence of the qacA/B gene in MRSA isolates. Antisepsis measures being crucial to prevent healthcare-associated infections, our findings raise questions about the potential risk associated with chlorhexidine use in qacA/B+ MRSA carriers, particularly in ICUs. Second, NHs are a weak link in MRSA control. MRSA spread was not controlled at several NHs; because of their frequent contact with the community, conditions are favorable for these NHs to serve as reservoirs of USA300 clone for local HCFs.
Collapse
Affiliation(s)
- Claire Rondeau
- UMR 1282, Réseau des Hygiénistes du Centre, Centre Hospitalier Universitaire de Tours Tours, France
| | - Guillaume Chevet
- UMR 1282, Réseau des Hygiénistes du Centre, Centre Hospitalier Universitaire de Tours Tours, France
| | - Dominique S Blanc
- Service of Hospital Preventive Medicine, Lausanne University Hospital Lausanne, Switzerland
| | - Houssein Gbaguidi-Haore
- Service d'Hygiène Hospitalière, Centre Hospitalier Universitaire de Besançon Besançon, France
| | - Marie Decalonne
- UMR 1282, Réseau des Hygiénistes du Centre, Centre Hospitalier Universitaire de Tours Tours, France
| | - Sandra Dos Santos
- Département de Bactériologie et Hygiène, Centre Hospitalier Universitaire de Tours Tours, France
| | - Roland Quentin
- Département de Bactériologie et Hygiène, Centre Hospitalier Universitaire de Tours Tours, France
| | - Nathalie van der Mee-Marquet
- UMR 1282, Réseau des Hygiénistes du Centre, Centre Hospitalier Universitaire de ToursTours, France; Département de Bactériologie et Hygiène, Centre Hospitalier Universitaire de ToursTours, France
| |
Collapse
|