1
|
Protocells: Milestones and Recent Advances. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2022; 18:e2106624. [PMID: 35322554 DOI: 10.1002/smll.202106624] [Citation(s) in RCA: 29] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2021] [Revised: 02/06/2022] [Indexed: 06/14/2023]
Abstract
The origin of life is still one of humankind's great mysteries. At the transition between nonliving and living matter, protocells, initially featureless aggregates of abiotic matter, gain the structure and functions necessary to fulfill the criteria of life. Research addressing protocells as a central element in this transition is diverse and increasingly interdisciplinary. The authors review current protocell concepts and research directions, address milestones, challenges and existing hypotheses in the context of conditions on the early Earth, and provide a concise overview of current protocell research methods.
Collapse
|
2
|
Manipulation of Lipid Membranes with Thermal Stimuli. Methods Mol Biol 2022; 2402:209-225. [PMID: 34854047 DOI: 10.1007/978-1-0716-1843-1_17] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
We describe a protocol for the assembly and application of infrared (IR-B) laser-based set-ups to be used for localized heating of solid-supported planar and vesicular lipid membrane assemblies.
Collapse
|
3
|
Dynamic Range Expansion of the C-Reactive Protein Quantification with a Tandem Giant Magnetoresistance Biosensor. ACS OMEGA 2021; 6:12923-12930. [PMID: 34056444 PMCID: PMC8154231 DOI: 10.1021/acsomega.1c01603] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Accepted: 04/26/2021] [Indexed: 05/03/2023]
Abstract
In this study, we report a convenient analytical method for a full-range quantification of the C-reactive protein (CRP), a blood biomarker of infection and cardiovascular events. We determine CRP over the entire diagnostically relevant concentration range in undiluted human blood serum in a single test, using a tandem giant magnetoresistance (GMR) sensor. The tandem principle combines a sandwich assay and a competitive assay, which allows for the discrimination of the concentration values resulting from the multivalued dose-response curve ("Hook" effect), which characterizes the one-step sandwich assay at high CRP concentrations. The sensor covers a linear detection range for CRP concentration from 3 ng/mL to 350 μg/mL, the detection limit (s/n = 3) is 1 ng/mL. The prominent features of the chip-based method are its expanded dynamic range and low sample volume (50 μL), and the need for a short measurement time of 15 min. These figures of merit, in addition to the low detection limit equal to the established assay instrumentation, make it a viable candidate for use in point-of-care diagnostics.
Collapse
|
4
|
A tandem giant magnetoresistance assay for one-shot quantification of clinically relevant concentrations of N-terminal pro-B-type natriuretic peptide in human blood. Anal Bioanal Chem 2021; 413:2943-2949. [PMID: 33624128 PMCID: PMC8043887 DOI: 10.1007/s00216-021-03227-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2020] [Revised: 01/28/2021] [Accepted: 02/08/2021] [Indexed: 11/28/2022]
Abstract
We report a microfluidic sandwich immunoassay constructed around a dual-giant magnetoresistance (GMR) sensor array to quantify the heart failure biomarker NT-proBNP in human plasma at the clinically relevant concentration levels between 15 pg/mL and 40 ng/mL. The broad dynamic range was achieved by differential coating of two identical GMR sensors operated in tandem, and combining two standard curves. The detection limit was determined as 5 pg/mL. The assay, involving 53 plasma samples from patients with different cardiovascular diseases, was validated against the Roche Cobas e411 analyzer. The salient features of this system are its wide concentration range, low detection limit, small sample volume requirement (50 μL), and the need for a short measurement time of 15 min, making it a prospective candidate for practical use in point of care analysis.
Collapse
|
5
|
Generation of interconnected vesicles in a liposomal cell model. Sci Rep 2020; 10:14040. [PMID: 32820180 PMCID: PMC7441142 DOI: 10.1038/s41598-020-70562-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2020] [Accepted: 06/08/2020] [Indexed: 12/04/2022] Open
Abstract
We introduce an experimental method based upon a glass micropipette microinjection technique for generating a multitude of interconnected vesicles (IVs) in the interior of a single giant unilamellar phospholipid vesicle (GUV) serving as a cell model system. The GUV membrane, consisting of a mixture of soybean polar lipid extract and anionic phosphatidylserine, is adhered to a multilamellar lipid vesicle that functions as a lipid reservoir. Continuous IV formation was achieved by bringing a micropipette in direct contact with the outer GUV surface and subjecting it to a localized stream of a Ca2+ solution from the micropipette tip. IVs are rapidly and sequentially generated and inserted into the GUV interior and encapsulate portions of the micropipette fluid content. The IVs remain connected to the GUV membrane and are interlinked by short lipid nanotubes and resemble beads on a string. The vesicle chain-growth from the GUV membrane is maintained for as long as there is the supply of membrane material and Ca2+ solution, and the size of the individual IVs is controlled by the diameter of the micropipette tip. We also demonstrate that the IVs can be co-loaded with high concentrations of neurotransmitter and protein molecules and displaying a steep calcium ion concentration gradient across the membrane. These characteristics are analogous to native secretory vesicles and could, therefore, serve as a model system for studying secretory mechanisms in biological systems.
Collapse
|
6
|
Supported Model Membranes for Biosensing Applications - Optical Oxytocin Binding Assay. Biophys J 2020. [DOI: 10.1016/j.bpj.2019.11.1376] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
7
|
Microfluidic technology for investigation of protein function in single adherent cells. Methods Enzymol 2019; 628:145-172. [PMID: 31668227 DOI: 10.1016/bs.mie.2019.07.038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/17/2023]
Abstract
Instrumental techniques and associated methods for single cell analysis, designed to investigate and measure a broad range of cellular parameters in search of unique features, address key limitations of conventional cell-based assays with their ensemble average response. While many different single cell techniques exist for suspension cultures, which can process and characterize large numbers of individual cells in rapid succession, the access to surface-immobilized cells in typical 2D and 3D culture environments remains challenging. Open space microfluidics has created new possibilities in this area, allowing for exclusive access to single cells in adherent cultures, even at high confluency. In this chapter, we briefly review new microtechnologies for the investigation of protein function in single adherent cells, and present an overview over related recent applications of the multifunctional pipette (Biopen), a microfluidic multi-solution dispensing system that uses hydrodynamic confinement in open volume environments in order to establish a superfusion zone over selected single cells in adherent cultures.
Collapse
|
8
|
Abstract
We investigated the interactions between styrene-maleic acid (SMA) copolymers and phospholipid bilayers, using confocal microscopy and surface acoustic wave resonance (SAR) sensing. For the first time we experimentally observed and followed pore formation by SMA copolymers in intact supported bilayers and unilamellar vesicles, showing that fluorescein, a water-soluble organic compound with a mean diameter of 6.9 Å, can traverse the membrane. Our findings are in agreement with recent theoretical predictions, which suggested that SMA copolymers may insert along the plane of the bilayer to form stable toroidal pores.
Collapse
|
9
|
Abstract
Assays are widely used for detection of various targets, including pathogens, drugs, and toxins. Homogeneous assays are promising for the realization of point-of-care diagnostics as they do not require separation, immobilization, or washing steps. For low concentrations of target molecules, the speed and sensitivity of homogeneous assays have hitherto been limited by slow binding kinetics, time-consuming amplification steps, and the presence of a high background signal. Here, we present a homogeneous differential magnetic assay that utilizes a differential magnetic readout that eliminates previous limitations of homogeneous assays. The assay uses a gradiometer sensor configuration combined with precise microfluidic sample handling. This enables simultaneous differential measurement of a positive test sample containing a synthesized Vibrio cholerae target and a negative control sample, which reduces the background signal and increases the readout speed. Very low concentrations of targets down to femtomolar levels are thus detectable without any additional amplification of the number of targets. Our homogeneous differential magnetic assay method opens new possibilities for rapid and highly sensitive diagnostics at the point of care.
Collapse
|
10
|
|
11
|
Molecular Lipid Films on Microengineering Materials. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2019; 35:10286-10298. [PMID: 31369272 DOI: 10.1021/acs.langmuir.9b01120] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
In this study, we have systematically investigated the formation of molecular phospholipid films on a variety of solid substrates fabricated from typical surface engineering materials and the fluidic properties of the lipid membranes formed on these substrates. The surface materials comprise of borosilicate glass, mica, SiO2, Al (native oxide), Al2O3, TiO2, ITO, SiC, Au, Teflon AF, SU-8, and graphene. We deposited the lipid films from small unilamellar vesicles (SUVs) by means of an open-space microfluidic device, observed the formation and development of the films by laser scanning confocal microscopy, and evaluated the mode and degree of coverage, fluidity, and integrity. In addition to previously established mechanisms of lipid membrane-surface interaction upon bulk addition of SUVs on solid supports, we observed nontrivial lipid adhesion phenomena, including reverse rolling of spreading bilayers, spontaneous nucleation and growth of multilamellar vesicles, and the formation of intact circular patches of double lipid bilayer membranes. Our findings allow for accurate prediction of membrane-surface interactions in microfabricated devices and experimental environments where model membranes are used as functional biomimetic coatings.
Collapse
|
12
|
Volume-amplified magnetic bioassay integrated with microfluidic sample handling and high- Tc SQUID magnetic readout. APL Bioeng 2017; 2:016102. [PMID: 31069287 PMCID: PMC6481700 DOI: 10.1063/1.4999713] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2017] [Accepted: 10/26/2017] [Indexed: 11/14/2022] Open
Abstract
A bioassay based on a high-Tc superconducting quantum interference device (SQUID) reading out functionalized magnetic nanoparticles (fMNPs) in a prototype microfluidic platform is presented. The target molecule recognition is based on volume amplification using padlock-probe-ligation followed by rolling circle amplification (RCA). The MNPs are functionalized with single-stranded oligonucleotides, which give a specific binding of the MNPs to the large RCA coil product, resulting in a large change in the amplitude of the imaginary part of the ac magnetic susceptibility. The RCA products from amplification of synthetic Vibrio cholera target DNA were investigated using our SQUID ac susceptibility system in microfluidic channel with an equivalent sample volume of 3 μl. From extrapolation of the linear dependence of the SQUID signal versus concentration of the RCA coils, it is found that the projected limit of detection for our system is about 1.0 × 105 RCA coils (0.2 × 10−18 mol), which is equivalent to 66 fM in the 3 μl sample volume. This ultra-high magnetic sensitivity and integration with microfluidic sample handling are critical steps towards magnetic bioassays for rapid detection of DNA and RNA targets at the point of care.
Collapse
|
13
|
SU-8 free-standing microfluidic probes. BIOMICROFLUIDICS 2017; 11:014112. [PMID: 28798844 PMCID: PMC5533480 DOI: 10.1063/1.4975026] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2016] [Accepted: 01/17/2017] [Indexed: 06/01/2023]
Abstract
We present a process for fabrication of free-standing SU-8 probes, with a dry, mechanical release of the final micro-devices. The process utilizes the thermal release tape, a commonly used cleanroom material, for facile heat-release from the sacrificial layer. For characterization of the SU-8 microfluidic probes, two liquid interfaces were designed: a disposable interface with integrated wells and an interface with external liquid reservoirs. The versatility of the fabrication and the release procedures was illustrated by further developing the process to functionalize the SU-8 probes for impedance sensing, by integrating metal thin-film electrodes. An additional interface scheme which contains electronic components for impedance measurements was developed. We investigated the possibilities of introducing perforations in the SU-8 device by photolithography, for solution sampling predominantly by diffusion. The SU-8 processes described here allow for a convenient batch production of versatile free-standing microfluidic devices with well-defined tip-geometry.
Collapse
|
14
|
Abstract
We simulate the formation of spontaneous ruptures in supported phospholipid double bilayer membranes, using peridynamic modeling. Experiments performed on spreading double bilayers typically show two distinct kinds of ruptures, floral and fractal, which form spontaneously in the distal (upper) bilayer at late stages of double bilayer formation on high energy substrates. It is, however, currently unresolved which factors govern the occurrence of either rupture type. Variations in the distance between the two bilayers, and the occurrence of interconnections (“pinning sites”) are suspected of contributing to the process. Our new simulations indicate that the pinned regions which form, presumably due to Ca2+ ions serving as bridging agent between the distal and the proximal bilayer, act as nucleation sites for the ruptures. Moreover, assuming that the pinning sites cause a non-zero shear modulus, our simulations also show that they change the rupture mode from floral to fractal. At zero shear modulus the pores appear to be circular, subsequently evolving into floral pores. With increasing shear modulus the pore edges start to branch, favoring fractal morphologies. We conclude that the pinning sites may indirectly determine the rupture morphology by contributing to shear stress in the distal membrane.
Collapse
|
15
|
Millimeter-wave sensor based on a λ/2-line resonator for identification and dielectric characterization of non-ionic surfactants. Sci Rep 2016; 6:19523. [PMID: 26786983 PMCID: PMC4726352 DOI: 10.1038/srep19523] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2015] [Accepted: 12/09/2015] [Indexed: 11/23/2022] Open
Abstract
Studies of biological and artificial membrane systems, such as niosomes, currently rely on the use of fluorescent tags, which can influence the system under investigation. For this reason, the development of label-free, non-invasive detection techniques is of great interest. We demonstrate an open-volume label-free millimeter-wave sensing platform based on a coplanar waveguide, developed for identification and characterization of niosome constituents. A design based on a λ/2-line resonator was used and on-wafer measurements of transmission and reflection parameters were performed up to 110 GHz. Our sensor was able to clearly distinguish between common niosome constituents, non-ionic surfactants Tween 20 and Span 80, measuring a resonance shift of 3 GHz between them. The complex permittivities of the molecular compounds have been extracted. Our results indicate insignificant frequency dependence in the investigated frequency range (3 GHz – 110 GHz). Values of permittivity around 3.0 + 0.7i and 2.2 + 0.4i were obtained for Tween 20 and Span 80, respectively.
Collapse
|
16
|
Graphene oxide based coatings on nitinol for biomedical implant applications: effectively promote mammalian cell growth but kill bacteria. RSC Adv 2016. [DOI: 10.1039/c6ra06026a] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
Abstract
Graphene oxide based coating significantly enhances the proliferation of osteoblastic cells and shows toxicity towards the bacterial cells.
Collapse
|
17
|
Nanopatterning of mobile lipid monolayers on electron-beam-sculpted Teflon AF surfaces. ACS NANO 2015; 9:1271-1279. [PMID: 25541906 DOI: 10.1021/nn5050867] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Direct electron-beam lithography is used to fabricate nanostructured Teflon AF surfaces, which are utilized to pattern surface-supported monolayer phospholipid films with 50 nm lateral feature size. In comparison with unexposed Teflon AF coatings, e-beam-irradiated areas show reduced surface tension and surface potential. For phospholipid monolayer spreading experiments, these areas can be designed to function as barriers that enclose unexposed areas of nanometer dimensions and confine the lipid film within. We show that the effectiveness of the barrier is defined by pattern geometry and radiation dose. This surface preparation technique represents an efficient, yet simple, nanopatterning strategy supporting studies of lipid monolayer behavior in ultraconfined spaces. The generated structures are useful for imaging studies of biomimetic membranes and other specialized surface applications requiring spatially controlled formation of self-assembled, molecularly thin films on optically transparent patterned polymer surfaces with very low autofluorescence.
Collapse
|
18
|
Lipid nanotube networks: Biomimetic Cell-to-Cell Communication and Soft-Matter Technology. NANOFABRICATION 2015. [DOI: 10.1515/nanofab-2015-0003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
|
19
|
A rapid microfluidic technique for integrated viability determination of adherent single cells. Anal Bioanal Chem 2014; 407:1295-301. [PMID: 25542567 DOI: 10.1007/s00216-014-8364-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2014] [Revised: 11/18/2014] [Accepted: 11/20/2014] [Indexed: 10/24/2022]
Abstract
Here, we report on a novel protocol for determining the viability of individual cells in an adherent cell culture, without adversely affecting the remaining cells in the sample. This is facilitated using a freestanding microfluidic perfusion device, the Multifunctional Pipette (MFP), which generates a virtual flow cell around selected single cells. We investigated the utility on four different cell lines, NG108-15, HEK 293, PC12, and CHO, and combined the assay with a cell poration experiment, in which we apply the pore-forming agent digitonin, followed by fluorescein diphosphate, a pre-fluorescent substrate for alkaline phosphatase, in order to monitor intracellular enzyme activity. The cell viability was instantly assessed through simultaneous perfusion with fluorescein diacetate (FDA) and propidium iodide (PI), both being dispensed through the same superfusion device used to porate and deliver the enzyme substrate. In this fluorescence assay, viable and non-viable cells were distinguished by their green and red emission, respectively, within 10 s. In addition, the enzyme activity was monitored over time as a secondary test for cellular activity. Our findings demonstrate that this microfluidic technology-assisted approach is a facile, rapid, and reliable means to determine the viability in single-cell experiments and that viability studies can be performed routinely alongside typical substrate delivery protocols. This approach would remove the need for global cell viability testing and would enable viability studies of only the cells under experimental analysis.
Collapse
|
20
|
A heating-superfusion platform technology for the investigation of protein function in single cells. Anal Chem 2014; 87:381-7. [PMID: 25457650 DOI: 10.1021/ac5031418] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Here, we report on a novel approach for the study of single-cell intracellular enzyme activity at various temperatures, utilizing a localized laser heating probe in combination with a freely positionable microfluidic perfusion device. Through directed exposure of individual cells to the pore-forming agent α-hemolysin, we have controlled the membrane permeability, enabling targeted delivery of the substrate. Mildly permeabilized cells were exposed to fluorogenic substrates to monitor the activity of intracellular enzymes, while adjusting the local temperature surrounding the target cells, using an infrared laser heating system. We generated quantitative estimates for the intracellular alkaline phosphatase activity at five different temperatures in different cell lines, constructing temperature-response curves of enzymatic activity at the single-cell level. Enzymatic activity was determined rapidly after cell permeation, generating five-point temperature-response curves within just 200 s.
Collapse
|
21
|
|
22
|
Abstract
We report a novel approach for determining the enzymatic activity within a single suspended cell. Using a steady-state microfluidic delivery device and timed exposure to the pore-forming agent digitonin, we controlled the plasma membrane permeation of individual NG108-15 cells. Mildly permeabilized cells (~100 pores) were exposed to a series of concentrations of fluorescein diphosphate (FDP), a fluorogenic alkaline phosphatase substrate, with and without levamisole, an alkaline phosphatase inhibitor. We generated quantitative estimates for intracellular enzyme activity and were able to construct both dose-response and dose-inhibition curves at the single-cell level, resulting in an apparent Michaelis contant Km of 15.3 μM ± 1.02 (mean ± standard error of the mean (SEM), n = 16) and an inhibition constant Ki of 0.59 mM ± 0.07 (mean ± SEM, n = 14). Enzymatic activity could be monitored just 40 s after permeabilization, and five point dose-inhibition curves could be obtained within 150 s. This rapid approach offers a new methodology for characterizing enzyme activity within single cells.
Collapse
|
23
|
Thermal migration of molecular lipid films as a contactless fabrication strategy for lipid nanotube networks. LAB ON A CHIP 2013; 13:3822-3826. [PMID: 23903381 DOI: 10.1039/c3lc50391g] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
We demonstrate the contactless generation of lipid nanotube networks by means of thermally induced migration of flat giant unilamellar vesicles (FGUVs), covering micro-scale areas on oxidized aluminum surfaces. A temperature gradient with a reach of 20 μm was generated using a focused IR laser, leading to a surface adhesion gradient, along which FGUVs could be relocated. We report on suitable lipid-substrate combinations, highlighting the critical importance of the electrostatic interactions between the engineered substrate and the membrane for reversible migration of intact vesicles.
Collapse
|
24
|
Lab on a Biomembrane: rapid prototyping and manipulation of 2D fluidic lipid bilayers circuits. Sci Rep 2013; 3:2743. [PMID: 24067786 PMCID: PMC3783038 DOI: 10.1038/srep02743] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2013] [Accepted: 08/28/2013] [Indexed: 11/11/2022] Open
Abstract
Lipid bilayer membranes are among the most ubiquitous structures in the living world, with intricate structural features and a multitude of biological functions. It is attractive to recreate these structures in the laboratory, as this allows mimicking and studying the properties of biomembranes and their constituents, and to specifically exploit the intrinsic two-dimensional fluidity. Even though diverse strategies for membrane fabrication have been reported, the development of related applications and technologies has been hindered by the unavailability of both versatile and simple methods. Here we report a rapid prototyping technology for two-dimensional fluidic devices, based on in-situ generated circuits of phospholipid films. In this "lab on a molecularly thin membrane", various chemical and physical operations, such as writing, erasing, functionalization, and molecular transport, can be applied to user-defined regions of a membrane circuit. This concept is an enabling technology for research on molecular membranes and their technological use.
Collapse
|
25
|
An optofluidic temperature probe. SENSORS (BASEL, SWITZERLAND) 2013; 13:4289-302. [PMID: 23539032 PMCID: PMC3673084 DOI: 10.3390/s130404289] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/26/2013] [Revised: 03/18/2013] [Accepted: 03/22/2013] [Indexed: 11/17/2022]
Abstract
We report the application of a microfluidic device for semi-contact temperature measurement in picoliter volumes of aqueous media. Our device, a freely positionable multifunctional pipette, operates by a hydrodynamic confinement principle, i.e., by creating a virtual flow cell of micrometer dimensions within a greater aqueous volume. We utilized two fluorescent rhodamines, which exhibit different fluorescent responses with temperature, and made ratiometric intensity measurements. The temperature dependence of the intensity ratio was calibrated and used in a model study of the thermal activation of TRPV1 ion channels expressed in Chinese hamster ovary cells. Our approach represents a practical and robust solution to the specific problem of measuring temperature in biological experiments in vitro, involving highly localized heat generation, for example with an IR-B laser.
Collapse
|
26
|
Fluctuations in Tat copy number when it counts the most: a possible mechanism to battle the HIV latency. Theor Biol Med Model 2013; 10:16. [PMID: 23497153 PMCID: PMC3686706 DOI: 10.1186/1742-4682-10-16] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2012] [Accepted: 02/12/2013] [Indexed: 01/27/2023] Open
Abstract
The HIV-1 virus can enter a dormant state and become inactive, which reduces accessibility by antiviral drugs. We approach this latency problem from an unconventional point of view, with the focus on understanding how intrinsic chemical noise (copy number fluctuations of the Tat protein) can be used to assist the activation process of the latent virus. Several phase diagrams have been constructed in order to visualize in which regions of the parameter space noise can drive the activation process. Essential to the study is the use of a hyperbolic coordinate system, which greatly facilitates quantification of how the various reaction rate combinations shape the noise behavior of the Tat protein feedback system. We have designed a mathematical manual of how to approach the problem of activation quantitatively, and introduce the notion of an “operating point” of the virus. For both noise-free and noise-based strategies we show how operating point off-sets induce changes in the number of Tat molecules. The major result of the analysis is that for every noise-free strategy there is a noise-based strategy that requires lower dosage, but achieves the same anti-latency effect. It appears that the noise-based activation is advantageous for every operating point.
Collapse
|
27
|
Kinetics of diffusion-mediated DNA hybridization in lipid monolayer films determined by single-molecule fluorescence spectroscopy. ACS NANO 2013; 7:308-315. [PMID: 23215045 DOI: 10.1021/nn304010p] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
We use single-molecule fluorescence microscopy to monitor individual hybridization reactions between membrane-anchored DNA strands, occurring in nanofluidic lipid monolayer films deposited on Teflon AF substrates. The DNA molecules are labeled with different fluorescent dyes, which make it possible to simultaneously monitor the movements of two different molecular species, thus enabling tracking of both reactants and products. We employ lattice diffusion simulations to determine reaction probabilities upon interaction. The observed hybridization rate of the 40-mer DNA was more than 2-fold higher than that of the 20-mer DNA. Since the lateral diffusion coefficient of the two different constructs is nearly identical, the effective molecule radius determines the overall kinetics. This implies that when two DNA molecules approach each other, hydrogen bonding takes place distal from the place where the DNA is anchored to the surface. Strand closure then propagates bidirectionally through a zipper-like mechanism, eventually bringing the lipid anchors together. Comparison with hybridization rates for corresponding DNA sequences in solution reveals that hybridization rates are lower for the lipid-anchored strands and that the dependence on strand length is stronger.
Collapse
|
28
|
Abstract
We present here a novel platform combination, using a multifunctional pipette to individually electroporate single-cells and to locally deliver an analyte, while in their culture environment. We demonstrate a method to fabricate low-resistance metallic electrodes into a PDMS pipette, followed by characterization of its effectiveness, benefits and limits in comparison with an external carbon microelectrode.
Collapse
|
29
|
Abstract
We have developed a microfluidic flow cell where stepwise enzymatic digestion is performed on immobilized proteoliposomes and the resulting cleaved peptides are analyzed with liquid chromatography-tandem mass spectrometry (LC-MS/MS). The flow cell channels consist of two parallel gold surfaces mounted face to face with a thin spacer and feature an inlet and an outlet port. Proteoliposomes (50-150 nm in diameter) obtained from red blood cells (RBC), or Chinese hamster ovary (CHO) cells, were immobilized on the inside of the flow cell channel, thus forming a stationary phase of proteoliposomes. The rate of proteoliposome immobilization was determined using a quartz crystal microbalance with dissipation monitoring (QCM-D) which showed that 95% of the proteoliposomes bind within 5 min. The flow cell was found to bind a maximum of 1 μg proteoliposomes/cm(2), and a minimum proteoliposome concentration required for saturation of the flow cell was determined to be 500 μg/mL. Atomic force microscopy (AFM) studies showed an even distribution of immobilized proteoliposomes on the surface. The liquid encapsulated between the surfaces has a large surface-to-volume ratio, providing rapid material transfer rates between the liquid phase and the stationary phase. We characterized the hydrodynamic properties of the flow cell, and the force acting on the proteoliposomes during flow cell operation was estimated to be in the range of 0.1-1 pN, too small to cause any proteoliposome deformation or rupture. A sequential proteolytic protocol, repeatedly exposing proteoliposomes to a digestive enzyme, trypsin, was developed and compared with a single-digest protocol. The sequential protocol was found to detect ~65% more unique membrane-associated protein (p < 0.001, n = 6) based on peptide analysis with LC-MS/MS, compared to a single-digest protocol. Thus, the flow cell described herein is a suitable tool for shotgun proteomics on proteoliposomes, enabling more detailed characterization of complex protein samples.
Collapse
|
30
|
Abstract
Microfluidics has emerged as a powerful laboratory toolbox for biologists, allowing manipulation and analysis of processes at a cellular and sub-cellular level, through utilization of microfabricated features at size-scales relevant to that of a single cell. In the majority of microfluidic devices, sample processing and analysis occur within closed microchannels, imposing restrictions on sample preparation and use. We present an optimized non-contact open-volume microfluidic tool to overcome these and other restrictions, through the use of a hydrodynamically confined microflow pipette, serving as a multifunctional solution handling and dispensing tool. The geometries of the tool have been optimised for use in optical microscopy, with integrated solution reservoirs to reduce reagent use, contamination risks and cleaning requirements. Device performance was characterised using both epifluorescence and total internal reflection fluorescence (TIRF) microscopy, resulting in ~200 ms and ~130 ms exchange times at ~100 nm and ~30 μm distances to the surface respectively.
Collapse
|
31
|
Radial sizing of lipid nanotubes using membrane displacement analysis. NANO LETTERS 2012; 12:1372-1378. [PMID: 22313341 PMCID: PMC3303199 DOI: 10.1021/nl203983e] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/11/2011] [Revised: 01/30/2012] [Indexed: 05/31/2023]
Abstract
We report a novel method for the measurement of lipid nanotube radii. Membrane translocation is monitored between two nanotube-connected vesicles, during the expansion of a receiving vesicle, by observing a photobleached region of the nanotube. We elucidate nanotube radii, extracted from SPE vesicles, enabling quantification of membrane composition and lamellarity. Variances of nanotube radii were measured, showing a growth of 40-56 nm, upon increasing cholesterol content from 0 to 20%.
Collapse
|
32
|
High-resolution micropatterned Teflon AF substrates for biocompatible nanofluidic devices. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2012; 28:3200-3205. [PMID: 22204476 DOI: 10.1021/la2044784] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
We describe a general photolithography-based process for the microfabrication of surface-supported Teflon AF structures. Teflon AF patterns primarily benefit from superior optical properties such as very low autofluorescence and a low refractive index. The process ensures that the Teflon AF patterns remain strongly hydrophobic in order to allow rapid lipid monolayer spreading and generates a characteristic edge morphology which assists directed cell growth along the structured surfaces. We provide application examples, demonstrating the well-controlled mixing of lipid films on Teflon AF structures and showing how the patterned surfaces can be used as biocompatible growth-directing substrates for cell culture. Chinese hamster ovary (CHO) cells develop in a guided fashion along the sides of the microstructures, selectively avoiding to grow over the patterned areas.
Collapse
|
33
|
Instrumental Methods to Characterize Molecular Phospholipid Films on Solid Supports. Anal Chem 2012; 84:822-38. [DOI: 10.1021/ac203126f] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
34
|
Mimicking Endocytosis Inside Giant Unilamellar Vesicles. Biophys J 2012. [DOI: 10.1016/j.bpj.2011.11.536] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
35
|
Direct Electron-Beam Nanopatterning of Teflon AF Surfaces for Site-Selective Formation of Molecular Phospholipid Films. Biophys J 2012. [DOI: 10.1016/j.bpj.2011.11.3948] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022] Open
|
36
|
Water coordinated zinc dioxo-chlorin and porphyrin self-assemblies as chlorosomal mimics: variability of supramolecular interactions. Photochem Photobiol Sci 2012; 11:1069-80. [DOI: 10.1039/c2pp25016k] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
37
|
Calcium Ion Controlled Nanoparticle Induced Tubulation in Supported Flat Phospholipid Vesicles. Biophys J 2012. [DOI: 10.1016/j.bpj.2011.11.534] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
|
38
|
|
39
|
Membrane Protrusion Coarsening and Nanotubulation within Giant Unilamellar Vesicles. J Am Chem Soc 2011; 133:18046-9. [DOI: 10.1021/ja207536a] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
|
40
|
Abstract
We describe micromanipulation and microinjection procedures for the fabrication of soft-matter networks consisting of lipid bilayer nanotubes and surface-immobilized vesicles. These biomimetic membrane systems feature unique structural flexibility and expandability and, unlike solid-state microfluidic and nanofluidic devices prepared by top-down fabrication, they allow network designs with dynamic control over individual containers and interconnecting conduits. The fabrication is founded on self-assembly of phospholipid molecules, followed by micromanipulation operations, such as membrane electroporation and microinjection, to effect shape transformations of the membrane and create a series of interconnected compartments. Size and geometry of the network can be chosen according to its desired function. Membrane composition is controlled mainly during the self-assembly step, whereas the interior contents of individual containers is defined through a sequence of microneedle injections. Networks cannot be fabricated with other currently available methods of giant unilamellar vesicle preparation (large unilamellar vesicle fusion or electroformation). Described in detail are also three transport modes, which are suitable for moving water-soluble or membrane-bound small molecules, polymers, DNA, proteins and nanoparticles within the networks. The fabrication protocol requires ∼90 min, provided all necessary preparations are made in advance. The transport studies require an additional 60-120 min, depending on the transport regime.
Collapse
|
41
|
Giant Unilamellar Vesicles with Internalized Poly-(n-Isopropylacrylamide)-Vinyl Ferrocene Copolymer (PNIPAAm-VFC), a New Membrane-Interactive Thermoresponsive Material. Biophys J 2011. [DOI: 10.1016/j.bpj.2010.12.2952] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
|
42
|
Fractal avalanche ruptures in biological membranes. NATURE MATERIALS 2010; 9:908-912. [PMID: 20935656 DOI: 10.1038/nmat2854] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/09/2010] [Accepted: 08/11/2010] [Indexed: 05/30/2023]
Abstract
Bilayer membranes envelope cells as well as organelles, and constitute the most ubiquitous biological material found in all branches of the phylogenetic tree. Cell membrane rupture is an important biological process, and substantial rupture rates are found in skeletal and cardiac muscle cells under a mechanical load. Rupture can also be induced by processes such as cell death, and active cell membrane repair mechanisms are essential to preserve cell integrity. Pore formation in cell membranes is also at the heart of many biomedical applications such as in drug, gene and short interfering RNA delivery. Membrane rupture dynamics has been studied in bilayer vesicles under tensile stress, which consistently produce circular pores. We observed very different rupture mechanics in bilayer membranes spreading on solid supports: in one instance fingering instabilities were seen resulting in floral-like pores and in another, the rupture proceeded in a series of rapid avalanches causing fractal membrane fragmentation. The intermittent character of rupture evolution and the broad distribution in avalanche sizes is consistent with crackling-noise dynamics. Such noisy dynamics appear in fracture of solid disordered materials, in dislocation avalanches in plastic deformations and domain wall magnetization avalanches. We also observed similar fractal rupture mechanics in spreading cell membranes.
Collapse
|
43
|
Direct access and control of the intracellular solution environment in single cells. Anal Chem 2010; 81:1810-8. [PMID: 19196030 DOI: 10.1021/ac802081m] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Methods that can control and vary the solution environment around single cells are abundant. In contrast, methods that offer direct access to the intracellular proteome and genome in single cells with the control, flexibility, and convenience given by microfluidic methods are both scarce and in great demand. Here, we present such a method based on using a microfluidic device mounted on a programmable scanning stage and cells on-chip permeabilized by the pore-forming glycoside digitonin. We characterized the on-chip digitonin poration, as well as the solution exchange within cells. Intracellular solution exchange times vary with the dose of exposure to digitonin from less than a second to tens of seconds. Also, the degree of permeabilization obtained for cells treated with the same dose varies considerably, especially for low doses of digitonin exposure and low permeabilities. With the use of the presented setup, the degree of permeabilization can be measured during the permeabilization process, which allows for "on-line" optimization of the digitonin exposure time. Using this calibrated permeabilization method, we demonstrate the generation of intracellular oscillations, intracellular gradients, and the delivery of substrate to initiate enzymatic reactions in situ. This method holds the potential to screen and titrate intracellular receptors or enzymes or to generate intracellular oscillations, useful in the study of signaling pathways and oscillation decoding among other applications.
Collapse
|
44
|
|
45
|
A method for heat-stimulated compression of poly(N-isopropyl acrylamide) hydrogels inside single giant unilamellar vesicles. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2010; 26:1-4. [PMID: 19916531 DOI: 10.1021/la9041524] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
In this letter, a hydrogel compression method for the facile generation of high polymer concentration within single giant unilamelar vesicles (GUV) is presented. A GUV with an internalized poly(N-isopropyl acrylamide) solution is heated above the lower critical solution temperature (LCST) until compartmentalization by collapsed hydrogel microaggregates occurs. Subsequently, the volume of the vesicle is decreased by reducing the area of the enclosing membrane. An increase in concentration by a factor of up to 11 is reached while the membrane remains intact, bringing the model system close to the living cell situation with its high concentration of proteins in the cytoplasm. The polymer-filled vesicles are also in a suitable density range to significantly improve the flow control performance of hydrogel valves embedded in soft matter nanofluidic devices.
Collapse
|
46
|
A Platform for Supramolecular Nanochemistry. Biophys J 2010. [DOI: 10.1016/j.bpj.2009.12.1038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
47
|
Micro- and Nanoscale Devices For Controlling Two-Dimensional Chemistry. Biophys J 2010. [DOI: 10.1016/j.bpj.2009.12.449] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
48
|
Multi-Dimensional Characterization of the Desensitization Behavior of Temperature- and H+-Activated Human TRPV1 Channels using Microfluidics. Biophys J 2010. [DOI: 10.1016/j.bpj.2009.12.1868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
|
49
|
Towards an electrowetting-based digital microfluidic platform for magnetic immunoassays. LAB ON A CHIP 2009; 9:3433-3436. [PMID: 19904412 DOI: 10.1039/b912646e] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
We demonstrate ElectroWetting-On-Dielectric (EWOD) transport and SQUID gradiometer detection of magnetic nanoparticles (MNPs) suspended in a 2 microl de-ionized water droplet. This proof-of-concept methodology constitutes the first development step towards a highly sensitive magnetic immunoassay platform with SQUID readout and droplet-based sample handling. Magnetic AC-susceptibility measurements were performed on MNPs with a hydrodynamic diameter of 100 nm using a high-Tc dc Superconducting Quantum Interference Device (SQUID) gradiometer as detector. We observed that the signal amplitude per unit volume is 2.5 times higher for a 2 microl sample droplet compared to a 30 microl sample volume.
Collapse
|
50
|
Abstract
We demonstrate that pulse width flow modulation (PWFM) can be used to design fast, accurate, and precise multistage dilution modules for microfluidic devices. The PWFM stage unit presented here yields 10-fold dilution, but several PWFM stages can be connected in series to yield higher-order dilutions. We have combined two stages in a device thus capable of diluting up to 100-fold, and we have experimentally determined a set of rules that can be conveniently utilized to design multistage diluters. Microfabrication with resist-based molds yielded geometrical channel height variances of 7% (22.9(16) microm) with corresponding hydraulic resistance variances of approximately 20%. Pulsing frequencies, channel lengths, and flow pressures can be chosen within a wide range to establish the desired diluter properties. Finally, we illustrate the benefits of on-chip dilution in an example application where we investigate the effect of the Ca(2+) concentration on a phospholipid bilayer spreading from a membrane reservoir onto a SiO(2) surface. This is one of many possible applications where flexible concentration control is desirable.
Collapse
|