1
|
Is the whitening effect of charcoal-based dentifrices related to their abrasive potential or the ability of charcoal to adsorb dyes? J Dent 2024; 140:104794. [PMID: 38035453 DOI: 10.1016/j.jdent.2023.104794] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Revised: 11/15/2023] [Accepted: 11/24/2023] [Indexed: 12/02/2023] Open
Abstract
OBJECTIVES To evaluate if tooth color alteration of activated charcoal-based dentifrices may be attributed to the dye adsorption potential of charcoal (chemical action - C - slurry only) or to the association of dye adsorption with abrasion (chemo-mechanical action - CM- slurry/toothbrushing). Potential adverse effects in surface roughness, gloss, and wear were also assessed. METHODS Bovine enamel/dentin specimens were randomly allocated into the groups according to treatments and test model (n = 15): deionized water (negative control- NC); Colgate Maximum Anticaries Protection (conventional toothpaste- positive control- PC); Colgate Luminous White Activated Charcoal (LW); Oral-B 3D White Therapy Charcoal (WT); Curaprox Black is White (BW); Dermavita Whitemax (Activated charcoal powder- WP). Specimens were exposed to the C or CM models, in 28-day staining-treatment cycling. Color change (ΔE00), whiteness index (ΔWID), percentage of alteration of surface roughness (%Raalt), and gloss (%GUalt) were calculated. Additional specimens (n = 9) were indented with a Knoop diamond and subjected to 100,000 abrasion cycles. Enamel wear was determined by calculating the decrease in indentations geometry. Data were analyzed by ANOVA/Tukey tests (α = 0.05). RESULTS The CM-model produced lower color change (staining) than C (p = 0.0001). PC, LW, WT, BW, and WP showed similar color results for both models, differing from NC (p < 0.05).%Ra and%GU did not differ among the C-model groups (p > 0.05) and WP exhibited the highest variation (%Ra and%GU) under CM-model. Enamel wear values were lowest in the NC and PC groups, intermediate for LW, WT, BW, and highest for the WP (p < 0.05). CONCLUSION Activated charcoal-based dentifrices have a similar ability to minimize tooth staining as the conventional toothpaste, with increased enamel wear potential in the long term (after 100,000 cycles). The activated charcoal powder damaged the enamel surface, showing a higher deleterious effect on enamel roughness, gloss, and wear. CLINICAL SIGNIFICANCE Dentifrices containing activated charcoal do not provide superior results to minimize tooth staining compared to conventional toothpaste. Charcoal powder should be used with caution because it promotes higher superficial alterations on the enamel surface.
Collapse
|
2
|
Film-Forming Polymers for Inhibition of Hydroxyapatite Dissolution: A Screening Study. Caries Res 2023; 57:602-612. [PMID: 37848001 DOI: 10.1159/000533546] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Accepted: 08/07/2023] [Indexed: 10/19/2023] Open
Abstract
The aim of this study was to evaluate the effect of film-forming polymer solutions of different concentrations and pH values, either associated or not with sodium fluoride (F; 225 ppm F-), when applied during the initial stage of salivary pellicle formation, to prevent the dissolution of hydroxyapatite (HA), which was determined by the pH-stat method. Polyacrylic acid (PA), chitosan, sodium linear polyphosphate (LPP), polyvinyl methyl ether/maleic anhydride (PVM/MA), and propylene glycol alginate (PGA) were tested in three concentrations (lower, medium, and higher), two pH values (native or adjusted), and either associated or not with F. Distilled water, F, and stannous ion+fluoride (Sn/F; 225 ppm F- and 800 ppm Sn2+, as SnCl2) solutions were the controls, totalizing 63 groups. HA crystals were pretreated with human saliva for 1 min to allow pellicle formation, then immersed in the experimental solutions (1 min), and exposed to saliva for another 28 min. Subsequently, they were added to a 0.3% citric acid solution (pH = 3.8), connected to a pH-stat system that added aliquots of 28 μL 0.1 N HCl for a total reaction time of 5 min. Data were analyzed with one-way ANOVA and Tukey's tests (α = 0.05). For PA alone, the concentrations of 0.1% (native pH), 0.06%, and 0.08% (both pH adjusted) showed significantly lower HA dissolution than the negative control. PA concentrations of 0.1% and 0.08%, of both pH values, improved the effect of F against HA dissolution to a near-identical value as Sn/F. All solutions containing chitosan and LPP significantly reduced HA dissolution in comparison with the control. For chitosan, the concentration of 0.5% (in both pH values) improved the effect of F. LPP at 0.5% (native pH) and all associations of LPP with F outperformed the effect of F. Some PVM/MA solutions significantly reduced HA dissolution but PVM/MA could not improve the protection of F. PGA was incapable of reducing HA dissolution or improving F effect. It was concluded that chitosan, LPP, and some PA and PVM/MA solutions used alone were capable of reducing HA dissolution. Only PA, chitosan, and LPP were able to enhance fluoride protection, but for PA and chitosan, this was influenced by the polymer concentration.
Collapse
|
3
|
Effect of whitening products on sound enamel and on artificial caries lesions during a cariogenic challenge. Clin Oral Investig 2023; 27:3105-3116. [PMID: 36809355 DOI: 10.1007/s00784-023-04916-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Accepted: 02/03/2023] [Indexed: 02/23/2023]
Abstract
OBJECTIVE To investigate the effect of fluoride-containing whitening products on sound enamel and on artificial caries lesions during a cariogenic challenge. MATERIALS AND METHODS Bovine enamel specimens (n = 120) with three areas [non-treated sound enamel (NSE), treated sound enamel (TSE), and treated artificial caries lesion (TACL)] were randomly assigned to the four groups: whitening mouthrinse (WM: 2.5% hydrogen peroxide-100 ppm F-), placebo mouthrinse (PM: 0% hydrogen peroxide-100 ppm F-), whitening gel (WG: 10% carbamide peroxide-1130 ppm F-), and deionized water (negative control; NC). The treatments (2 min for WM, PM, and NC, and 2 h for WG) were carried out during a 28-day pH-cycling model (6 × 60 min demineralization/day). Relative surface reflection intensity (rSRI) and transversal microradiography (TMR) analyses were performed. Fluoride uptake (surface and subsurface) was measured in additional enamel specimens. RESULTS For TSE, a higher value of rSRI was observed in WM (89.99% ± 6.94), and a greater decrease in rSRI was observed for WG and NC, and no sign of mineral loss was verified for all groups (p > 0.05). For TACL, rSRI significantly decreased after pH-cycling for all experimental groups with no difference between them (p < 0.05). Higher amounts of fluoride were found in WG. WG and WM exhibited intermediate values of mineral loss, similar to PM. CONCLUSIONS The whitening products did not potentialize the enamel demineralization under a severe cariogenic challenge, and they did not exacerbate mineral loss of the artificial caries lesions. CLINICAL RELEVANCE Low concentrated hydrogen peroxide whitening gel and mouthrinse containing fluoride do not intensify the progression of caries lesions.
Collapse
|
4
|
Tooth color change promoted by different whitening toothpastes under alternate cycles of staining and brushing. J Dent 2023; 132:104498. [PMID: 36963626 DOI: 10.1016/j.jdent.2023.104498] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2023] [Revised: 03/03/2023] [Accepted: 03/21/2023] [Indexed: 03/26/2023] Open
Abstract
OBJECTIVES To compare the effect of whitening toothpastes with different mechanisms of action on discolored teeth subjected to additional staining/or not. METHODS One hundred twenty tooth specimens were stained for 14 days (staining broth under constant agitation and pH=7) and then allocated into the groups of toothpastes with different whitening ingredients (n=10): 1. Regular - Colgate Total 12 Clean Mint; 2. CLWI - Colgate Luminous White Instant (blue pigment); 3. CLWA - Colgate Luminous White Advanced Expert (hydrogen peroxide); 4. CLWAC - Colgate Luminous White Activated Charcoal (activated charcoal); 5. OB3D - Oral-B 3D WHITE Brilliant Fresh (abrasive); 6. TW - Teeth Whitening (charcoal powder). Specimens were submitted to two experimental models: A. Daily staining-toothbrush cycling: staining solution (5min), toothbrushing (45 strokes) and artificial saliva (3h), 2x/day, for 5days; B. Only toothbrushing (30.000 brushing strokes). Color change was determined with a spectrophotometer (CIEDE2000 and Whitening Index for Dentistry - WID) and statistically analyzed (α=0.05). RESULTS For both models, ΔE00 and Δa did not differ significantly between the whitening toothpastes and the regular. All groups showed a decrease in tooth yellowness (-Δb) and an increase in WID. Group Teeth Whitening exhibited a decrease in luminosity (-ΔL). In model A, Groups did not differ significantly from the Regular in terms of ΔL (p=0.35) and Δb (p=0.74). Groups CLWI and OB3D exhibited a decrease in luminosity. Reduced redness (-Δa) occurred only in Group CLWI. In Model B, Groups OB3D (p=0.021) and CLWA (p=0.001) exhibited higher change in luminosity than in Group Teeth Whitening. All exhibited increased redness (+Δa) and lightness (+ΔL), except the Regular, CLWAC and Teeth Whitening. Group OB3D had a significantly higher change in Δb than the Regular (p=0.021). CONCLUSIONS Irrespective of the mechanism of action, all toothpastes reduced tooth yellowness and promoted similar overall color change. Exposure of the teeth to additional staining during the toothbrushing cycles did not influence the effect of the whitening toothpastes. CLINICAL SIGNIFICANCE Whitening toothpastes should be tested in conditions that more closely simulate their use in a clinical scenario, in which alternate cycles of staining and brushing occur on a daily basis. However, even in such conditions, they were unable to promote a color change that differed from that of a regular toothpaste.
Collapse
|
5
|
Influence of Viscosity and Thickener on the Effects of Bleaching Gels. Oper Dent 2022; 47:E119-E130. [PMID: 35649221 DOI: 10.2341/20-309-l] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/06/2021] [Indexed: 11/23/2022]
Abstract
OBJECTIVE This study investigated the influence of the viscosity and kind of thickener of 35% hydrogen peroxide bleaching gels on the tooth (color change, demineralization of enamel, and permeation) and on the gel [reactive oxygen species (ROS), pH, and peroxide concentration]. METHODS AND MATERIALS Two hundred forty specimens were divided into groups of bleaching gels with different thickeners (CAR, carbomer; ASE, alkali swellable emulsion; MSA, modified sulfonic acid polymer; SSP, semisynthetic polysaccharide; PAC, particulate colloids) in three viscosities (low: 50,000 cP; medium: 250,000 cP; high: 1,000,000 cP). Color change (ΔEab), demineralization of enamel by Knoop microhardness (KHN) reduction analysis, and peroxide permeation (PP) were analyzed in the specimens, while pH, peroxide concentration (PC), and ROS were evaluated in the gels. Data were analyzed by two-way ANOVA (α=0.05). RESULTS The higher viscosity gels reduced ΔEab, PP, enamel softening, and ROS in relation to the lower viscosity gels. However, the drop in pH and PC were higher in the more viscous gels. Gels with MSA produced higher ΔEab compared with SSP and ASE. The PP was higher for PAC, and smaller for SSP and CAR. The KHN reduction was higher for CAR and smaller for PAC. The higher pH reduction was seen for ASE and CAR, and the smaller for SSP. The PC reduction was higher for SSP and smaller for CAR. More ROS were observed for MSA and fewer for ASE. CONCLUSIONS Increased gel viscosity was associated with reduced color change, permeation, demineralization of enamel, and ROS, and led to increased peroxide decomposition and pH alteration during the treatment. The kind of thickener significantly interfered with the treatment effects.
Collapse
|
6
|
S-PRG-based composites erosive wear resistance and the effect on surrounding enamel. Sci Rep 2022; 12:833. [PMID: 35039516 PMCID: PMC8764067 DOI: 10.1038/s41598-021-03745-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Accepted: 10/26/2021] [Indexed: 11/09/2022] Open
Abstract
This study evaluated Surface Pre-Reacted Glass-ionomer (S-PRG)-based-composites' surface resistance against erosive wear and their protective effect on surrounding enamel. Bovine enamel was randomized into 12 groups (n = 10/group) [erosion (e) or erosion + abrasion (a)]: nanohybrid-S-PRG-based composite (SPRGe/SPRGa), nanohybrid-S-PRG-based bulk-fill (SPRGBFe/SPRGBFa), nanoparticle-composite (RCe/RCa), nanohybrid-bulk-fill (BFe/BFa), Glass Hybrid Restorative System (GHRSe/GHRSa), and resin-modified glass-ionomer-cement (RMGICe/RMGICa). Cavities were prepared and restored. Initial profile assessment was performed on material and on adjacent enamel at distances of 100, 200, 300, 600, and 700 μm from margin. Specimens were immersed in citric acid (2 min; 6×/day for 5 days) for erosion. Erosion + abrasion groups were brushed for 1 min after erosion. Final profile assessment was performed. Two-way ANOVA and Tukey-test showed: for erosion, the GHRSe and RMGICe presented greater material wear compared to the other groups (p = 0.001); up to 300 μm away from restoration, GHRSe and SPRGBFe were able to prevent enamel loss compared to RMGICe and other composite groups (p = 0.001). For erosion + abrasion, none of the materials exhibited a significant protective effect and S-PRG-based groups showed lower wear than RMGICa and GHRSa, and higher wear than composites (p = 0.001). S-PRG-based-composites can diminish surrounding enamel loss only against erosion alone, similarly to GIC, with advantage of being a more resistant material.
Collapse
|
7
|
Effect of whitening mouthrinses on color change of stained resin composites. BRAZILIAN DENTAL SCIENCE 2022. [DOI: 10.4322/bds.2022.e2773] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
8
|
Glass Ionomer Versus Self-adhesive Cement and the Clinical Performance of Zirconia Coping/Press-on Porcelain Crowns. Oper Dent 2021; 46:362-373. [PMID: 34491349 DOI: 10.2341/20-229-c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/29/2020] [Indexed: 11/23/2022]
Abstract
OBJECTIVE This split-mouth clinical study investigated the effect of luting cement on the performance of veneered yttrium-stabilized tetragonal zirconia polycrystal (Y-TZP) zirconia crowns. METHODS AND MATERIALS A total of 60 crowns prepared with Y-TZP coping and press-on porcelain were made with a split-mouth design in 30 participants. The crowns were cemented either with glass ionomer cement (GIC) (Meron, Voco) or with self-adhesive resin cement (Bifix-SE, Voco). The restorations were assessed immediately after treatment and after 6, 12, 24, 36, and 48 months using the modified United States Public Health Service criteria. The parameters analyzed were retention, color stability, marginal discoloration, marginal adaptation, surface roughness, anatomic form, and secondary caries. The differences between the groups were analyzed by the Fisher exact test in each period of evaluation. The survival rate was analyzed with the Kaplan-Meier and log-rank test (α=0.05). RESULTS After 48 months, 20 participants attended the recall. During the period of evaluation, 1 crown cemented with glass ionomer cement and 1 crown cemented with resin cement lost retention. Color match, marginal discoloration and adaptation, surface roughness, and anatomic form did not change in any of the periods evaluated, and no secondary caries was observed. No significant differences were found between the 2 luting cements for any of the clinical parameters analyzed, nor for the survival rates during the study. CONCLUSIONS The type of cement did not influence the performance of the crowns after 48 months of clinical use. Both cements resulted in adequate retention rates, aesthetic and functional outcomes, and biological response.
Collapse
|
9
|
Efficacy of fluoride varnishes with different compositions on white spot lesions remineralization. BRAZILIAN DENTAL SCIENCE 2021. [DOI: 10.14295/bds.2021.v24i3.2478] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Objective: To evaluate the efficacy of different fluoride varnishes on white spot lesions (WSL) remineralization. Material and Methods: Polished bovine enamel specimens were obtained (n = 60) and had their initial surface Knoop microhardness (SMH) determined. WSL were created and the SMH was measured again. Then, specimens were allocated into six groups: C – Control (without varnish); BF – Bifluorid 12 (6% NaF + 6% CaF2); DP – Duraphat (5% NaF); PF – Profluorid (5% NaF); FP - Fluor Protector (0.2% NaF + 0.9% difluorsilane); CW - Clinpro White Varnish (5% NaF + 5% TCP). After varnishes application, specimens were immersed in artificial saliva for 24 h. Then, pH-cycling was performed for 8 days and SMH was measured. Data were analyzed by one-way ANOVA and Tukey’s test. Results: Non-significant differences were observed among the groups at baseline (p = 0.187) and after WSL formation (p = 0.999). After treatments, significant differences were observed among the groups (p = 0.001). Mean % of alteration (SD) and results of Tukey test were: C- 92.40 (12.10)a; PF- 88.66 (10.66)a; FP- 85.90 (14.49)ab; BF- 67.85 (17.86)bc; CW- 66.60 (18.48)c; DP- 58.62 (8.69)c. Conclusion:. Bifluorid 12, Clinpro White Varnish, and Duraphat showed higher efficacy than artificial saliva in promoting the remineralization of WSL, nevertheless, none of the treatments were able to recover sound enamel baseline microhardness.
Keywords
Dental caries; Fluoride; Fluoride varnishes.
Collapse
|
10
|
Erosive tooth wear inhibition by hybrid coatings with encapsulated fluoride and stannous ions. JOURNAL OF MATERIALS SCIENCE. MATERIALS IN MEDICINE 2021; 32:83. [PMID: 34212232 PMCID: PMC8249257 DOI: 10.1007/s10856-021-06554-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Accepted: 06/07/2021] [Indexed: 06/13/2023]
Abstract
This study aimed to formulate a hybrid coating material (HC) and to modify this HC with fluoride (NaF) and stannous (SnCl2) ions, directly or encapsulated in nano containers, testing the effects of these materials against dental erosion and erosion-abrasion. Enamel and dentin specimens were treated with the HCs, and then tested in erosion or erosion-abrasion cycling models of 5 days (n = 10 for each substrate, for each model). Deionized water was the negative control, and a fluoride varnish, the positive control. Surface loss (SL, in µm) was evaluated with an optical profilometer, and data were statistically analyzed (α = 0.05). For enamel, in erosion, the positive control and HC without additives showed significantly lower SL than the negative control (p = 0.003 and p = 0.001). In erosion-abrasion, none of the groups differed from the negative control (p > 0.05). For dentin, in erosion, the positive control, HC without additives, HC with non-encapsulated F, and HC with encapsulated F + Sn showed lower SL than the negative control (p < 0.05). In erosion-abrasion, none of the groups differed significantly from the negative control (p < 0.05). HC without additives showed a promising potential for protecting the teeth against dental erosion (with upward trend for improved protection on dentin), but not against erosion-abrasion. The presence of additives did not improve the protective effect of the HC, on both substrates.
Collapse
|
11
|
Efficacy and Safety of Bleaching Gels According to Application Protocol. Oper Dent 2021; 46:E105-E116. [PMID: 34086959 DOI: 10.2341/19-253-l] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/04/2020] [Indexed: 11/23/2022]
Abstract
OBJECTIVES This study evaluated bleaching efficacy, enamel microhardness, and roughness of highly concentrated hydrogen peroxide (HP) gels (35%-40%) using different application protocols. Gel decomposition and pH alteration were also analyzed. METHODS AND MATERIALS Bovine enamel/dentin specimens were divided into groups according to the bleaching gel-Pola Office Plus (POP-SDI, 37.5% HP), Opalescence Boost (OPB-Ultradent, 40% HP), Whiteness HP (WHP-FGM, 35% HP)- and application protocol-single application (SA) and multiple application (MA) during the in-office session. Deionized water was used in control group (no bleaching). Thus, seven final groups were obtained (n=15/group). Color (CIE L*a*b*), surface microhardness (SMH), and roughness (Ra) were assessed before/after treatments. The pH of gels was measured, and HP concentration was determined with potassium permanganate titration method in different times. Data were submitted to analysis of variance and Tukey tests (5%). RESULTS All gels presented similar and clinically acceptable bleaching efficacy (ΔE>2.7) for both SA and MA, as well as no significant differences for SMH and Ra comparing the two protocols in the same gel. Peroxide decomposition significantly increased with time, but final gel concentrations were still high after 45 minutes (32.29% POP; 38.45% OPB; and 32.74% WHP). The pH decreased over time (initial - after 45 min) for WHP (6.83±0.07 - 5.81±0.06), but minimal alterations were observed for POP (8.09±0.09 - 7.88±0.07) and OPB (7.82±0.11 - 7.87±0.07). CONCLUSIONS Peroxide decomposition was very low for all gels tested, and pH remained stable for POP and OPB gels. Bleaching protocol did not influence whitening efficacy and hazardous effects over enamel, thus potentially there was no clinical significance. Therefore, for the products tested, there is no evidence for recommending the gel change during the bleaching session.
Collapse
|
12
|
Protective Effect of Solutions Containing Polymers Associated with Fluoride and Stannous Chloride on Hydroxyapatite Dissolution. Caries Res 2021; 55:122-129. [PMID: 33503639 DOI: 10.1159/000513444] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2020] [Accepted: 11/29/2020] [Indexed: 11/19/2022] Open
Abstract
This study investigated the protective effect of experimental solutions containing 4 polymers (polyoxirane, hydroxypropylmethylcellulose [HPMC], pectin, and an amino methacrylate copolymer [AMC]) in 2 concentrations (low and high) associated or not with sodium fluoride (F; 225 ppm F-) or sodium fluoride plus stannous chloride (FS; 800 ppm Sn2+) on the dissolution of hydroxyapatite crystals (HA). Deionized water was the control. The pretreated HA was added to a 0.3% citric acid solution (pH 3.8). An automatic titrant machine added aliquots of 0.1 N HCl at a rate of 28 μL/min, in a total reaction time of 5 min. Groups were compared with 2-way ANOVA and Tukey's test, and concentrations with Student t test (5%). The zeta potential of the HA treated with the solutions was measured. Significant differences were found for both factors and interaction (p < 0.0001). The treatments with F and FS solutions resulted in a lower amount of dissolved HA than the control. Among the polymers' solutions, only AMC was able to reduce the amount of dissolved HA, changing the surface charge of HA to positive. AMC improved the protective effect of F, but it did not affect FS. Polyoxirane and HPMC reduced the protective potential of the FS solution. No differences were found between the concentrations of the polymers. It was concluded that F and FS reduced the amount of dissolved HA. The protective effect of the experimental solutions against HA dissolution was polymer dependent. The F effect was enhanced by its combination with AMC, but the protection of FS was impaired by polyoxirane and HPMC.
Collapse
|
13
|
The Addition of Propylene Glycol Alginate to a Fluoride Solution to Control Enamel Wear: An in situ Study. Caries Res 2020; 54:517-523. [PMID: 33176315 DOI: 10.1159/000511261] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Accepted: 09/01/2020] [Indexed: 11/19/2022] Open
Abstract
The aim of this study was to evaluate the protective effect of propylene glycol alginate (PGA) associated with sodium fluoride (NaF) against enamel erosion and erosion-abrasion. A 4-phase, split-mouth, double-blind, crossover in situ trial was conducted with the following solutions: F + PGA (225 ppm F- + 0.1% PGA), F (225 ppm F-), F + Sn (225 ppm F- + SnCl2, 800 ppm Sn2+), and negative control (distilled water). In each phase, 12 subjects wore removable mandibular appliances containing 4 enamel specimens, which were submitted either to erosion or to erosion-abrasion challenges for 5 days. Acquired salivary pellicle was formed in situ for 2 h. Erosion-abrasion consisted of acid challenge (1% citric acid solution, pH 2.3, 5 min, 4×/day), exposure to saliva in situ (2 h, 4×/day), brushing (5 s, total 2 min exposure to the slurry), and treatment with the solutions (2 min, 2×/day). For erosion, the same procedures were performed, without brushing. At the end, surface loss (SL; in μm) was evaluated by means of optical profilometry. KOH-soluble fluoride was quantified for erosion-only groups using extra specimens. For both challenges, the SL values found for F + PGA did not differ significantly from those of F and the negative control, and the SL value shown for F + Sn was significantly the lowest. Erosion-abrasion promoted significantly higher SL values than erosion. KOH-soluble fluoride analysis showed that F + Sn had a higher fluoride concentration in comparison with the negative control and F, while F + PGA did not differ from any of the other groups. In conclusion, PGA was not able to improve the protective effect of NaF against erosive enamel wear.
Collapse
|
14
|
Pure Ormocer vs Methacrylate Composites on Posterior Teeth: A Double-blinded Randomized Clinical Trial. Oper Dent 2020; 45:359-367. [PMID: 32053457 DOI: 10.2341/19-079-c] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/21/2019] [Indexed: 11/23/2022]
Abstract
CLINICAL RELEVANCE The clinical behavior of pure ormocer composite is reliable when used in class II restorations after 24 months of evaluation. SUMMARY
Collapse
|
15
|
Assessment of Peroxide in Saliva During and After At-home Bleaching With 10% Carbamide and Hydrogen Peroxide Gels: A Clinical Crossover Trial. Oper Dent 2020; 45:368-376. [PMID: 32216723 DOI: 10.2341/19-127-c] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/24/2019] [Indexed: 11/23/2022]
Abstract
CLINICAL RELEVANCE This study suggests that at-home bleaching systems are safe in relation to toxicity based on peroxide levels in saliva since the amount of peroxide potentially ingested is much lower than the estimated toxic dose. SUMMARY
Collapse
|
16
|
Bioactive Materials Subjected to Erosion/Abrasion and Their Influence on Dental Tissues. Oper Dent 2020; 45:E114-E123. [PMID: 32053454 DOI: 10.2341/19-102-l] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVE The objective of this study was to evaluate the effect of erosion or erosion-abrasion on bioactive materials and adjacent enamel/dentin areas. METHODS AND MATERIALS Enamel and dentin blocks (4×4×2 mm) were embedded side by side in acrylic resin, and a standardized cavity (1.2×4×1.5 mm) was prepared between them. Preparations were restored with the following materials: composite resin (Filtek Z350, control); experimental composite containing di-calcium phosphate dihydrate particles (DCPD); Giomer (Beautifil II), high viscosity glass ionomer cement (GIC, Fuji IX); and a resin-modified GIC (Fuji II LC). The specimens were submitted to two cycling models (n=10): erosion or erosion-abrasion. The challenges consisted of five-minute immersion in 0.3% citric acid solution, followed by 60-minute exposure to artificial saliva. Toothbrushing was carried out twice daily, 30 minutes after the first and last exposures to acid. Dental and material surface loss (SL, in μm) were determined by optical profilometry. Data were analyzed with Kruskal-Wallis and Dunn tests (α=0.05). RESULTS Under erosion, for enamel, only the GIC groups presented lower SL values than Z350 (p<0.001 for Fuji IX and p=0.018 for Fuji II LC). For dentin, none of the materials showed significantly lower SL values than Z350 (p>0.05). For material, the GICs had significantly higher SL values than those of Z350 (p<0.001 for Fuji IX and p=0.002 for Fuji II LC). Under erosion-abrasion, the enamel SL value was significantly lower around Fuji II LC compared with the other materials (p<0.05). No significant differences were observed among groups for dentin SL (p=0.063). The GICs and Giomer showed higher SL values than Z350 (p<0.001 for the GICs and p=0.041 for Giomer). CONCLUSION Both GIC-based materials were susceptible to erosive wear; however, they promoted the lowest erosive loss of adjacent enamel. Against erosion-abrasion, only Fuji II LC was able to reduce enamel loss. For dentin, none of the materials exhibited a significant protective effect.
Collapse
|
17
|
Do Tooth- and Cavity-related Aspects of Noncarious Cervical Lesions Affect the Retention of Resin Composite Restorations in Adults? A Systematic Review and Meta-analysis. Oper Dent 2020; 45:E124-E140. [PMID: 32053461 DOI: 10.2341/19-091-l] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
PURPOSE The purpose was to perform a systematic review and meta-analysis based on the following research question: do tooth- and cavity-related aspects of noncarious cervical lesions (NCCLs) affect the retention of composite restorations? METHODS Randomized clinical trials (RCTs) that evaluated the retention rate of resin restorations in NCCLs were included for the identification and comparison of their characteristics. The search was conducted in PubMed and adapted for Scopus, Web of Science, Latin American and Caribbean Health Sciences Literature database (LILACS), Brazilian Library in Dentistry (BBO), Cochrane Library, and System for Information on Grey Literature in Europe (SIGLE) without restrictions until July 2018. Unpublished and ongoing trial registries were also searched. The Cochrane Collaboration tool was used for assessing risk of bias. The quality of the evidence was graded using the Grading of Recommendations: Assessment, Development and Evaluation. Using the random effects model, a meta-analysis was conducted for each aspect (arch distribution, tooth location, wear facets, dentin sclerosis, shape, size, depth, occluso-gingival distance, and margin location). RESULTS We retrieved 6738 articles. After removal of duplicates and nonrelevant articles, 24 RCTs remained. The anterior tooth location favored the retention rates of restoration of NCCLs (relative risk [RR], 1.08; 95% confidence interval [CI], 1.00-1.16). The presence of wear facets is a risk factor for the retention of restorations (RR, 0.91; 95% CI, 0.83-0.99). The evidence was moderate for arch distribution and low or very low for all other factors because of heterogeneity, imprecision, and inconsistency. CONCLUSION The tooth location and the presence of wear facets can affect the retention of composite resins in NCCLs.
Collapse
|
18
|
Abstract
Background: The purpose of this study was to evaluate the effect of different bonding agents on bond-strength to demineralized enamel after remineralizing treatments and resin infiltration. Methods: Buccal enamel of 120 bovine incisors was polished and then were divided into five experimental groups: SE (sound enamel); DE (demineralized enamel); AS (demineralized enamel immersed in artificial saliva for eight weeks); NaF (demineralized enamel treated with 0.05% sodium fluoride solution (one minute) for eight weeks); Ic (demineralized enamel infiltrated with a low-viscosity resin (Icon-DGM). These groups were subdivided according to adhesive system used: self-etching adhesive Adper Easy One (3M/ESPE) and etch-and-rinse adhesive Single Bond (3M/ESPE). The composite resin blocks were fabricated using a Teflon matrix. A thermomechanical cycling machine was used to carry out the artificial aging of the specimens and thus were sectioned into sticks. The microtensile tests were performed using a universal testing machine at a cross-head speed of 1 mm/min. Data (in MPa) were subjected to two-way ANOVA and Tukey's tests (5%). Results: Significant differences were found for both factors tested and interactions (p<0.05). Tukey's test results of µTBS (mean ± SD) were: etch-and-rinse SE (28.79±3.93); DE (30.41±7.22); AS (29.03±3.33); NaF (29.81±4.06)a; Ic (29.47±5.5); and self-etching SE (30.37±6.96); DE (14.62±4.47); AS (9.79±2.32); NaF (9.36±2.31); Ic (30.78±8.68). Conclusions: Resin infiltration did not affect the bond strength of demineralized enamel for both adhesive systems tested. For etch-and-rinse adhesive, no differences were observed for the tested groups. For self-etching adhesive, only the resin-infiltrated group showed similar bond strength to sound enamel. Both etch-and-rinse and self-etching adhesive systems can be used in resin-infiltrated enamel, if a composite restoration needs to be further performed. In enamel that has undergone the de/remineralization process, the use of a total-etch adhesive might be preferable for the restorative procedure.
Collapse
|
19
|
Effect of Calcium and Fluoride Addition to Hydrogen Peroxide Bleaching Gel On Tooth Diffusion, Color, and Microhardness. Oper Dent 2019; 44:424-432. [DOI: 10.2341/18-113-l] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objectives:
The aim of this study was to evaluate the effect of calcium and fluoride addition to a 35% hydrogen peroxide (HP) bleaching gel with regard to its diffusion through the tooth structure, enamel microhardness, and bleaching efficacy.
Methods and Materials:
Eighty specimens (6 mm in diameter and 2 mm in height; 1 mm/enamel and 1 mm/dentin) were obtained from bovine incisors that were polished and divided into four groups (n=20) according to the remineralizing agent added to the gel: Ca = 0.5% calcium gluconate; F = 0.2% sodium fluoride; Ca+F = 0.5% calcium gluconate and 0.2% sodium fluoride; and control = no agent. Initial microhardness and color were assessed. The samples were positioned over simulated pulpal chambers filled with acetate buffer solution to capture the HP. Gels were applied over enamel for 30 minutes, and HP diffusion was assessed by spectrophotometry two hours after bleaching. Microhardness was measured immediately after bleaching and then the specimens were immersed into artificial saliva for seven days for final color assessment. Data were analyzed by one-way analysis of variance followed by Tukey test.
Results:
Bleaching reduced microhardness for all groups (p=0.0001), but the Ca+F and F groups showed lower reductions after bleaching. The addition of Ca, F, and Ca+F decreased the peroxide penetration through the tooth structure (p=0.0001), but there were no differences in color change for ΔL (p=0.357), Δa (p=0.061), Δb (p=0.823), and ΔE (p=0.581).
Conclusion:
The addition of calcium and fluoride in the gel did not affect bleaching efficacy, but it was able to reduce both the peroxide diffusion and the bleached enamel microhardness loss.
Collapse
|
20
|
Effect of Remineralizing Gels on Microhardness, Color and Wear Susceptibility of Bleached Enamel. Oper Dent 2019; 44:76-87. [DOI: 10.2341/17-150-l] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objectives:
To evaluate the effect of a remineralizing gel combining fluoride and calcium silicate/phosphate or a sodium fluoride gel on bleached enamel microhardness, color, and wear susceptibility.
Methods and Materials:
Two hundred forty bovine enamel-dentin samples were prepared. Baseline analysis of Knoop microhardness, color coordinates (L*a*b*), and surface profile were performed. According to the baseline microhardness values, specimens were stratified into six groups (n=40): NC (negative control)—no treatment; BL (positive control)—bleaching with 40% hydrogen peroxide gel (Opalescence Boost, Ultradent); BL/Rs—bleaching + application of calcium silicate/phosphate gel (Regenerate Serum, Unilever - Rs); Rs/BL—Rs + bleaching; Rs/BL/Rs—Rs + bleaching + Rs; and BL/F—bleaching + 2% sodium fluoride gel. After the treatment described for each group, color change (ΔE) and microhardness were evaluated again. To evaluate abrasion susceptibility, samples were randomly divided into two subgroups, according to the toothpaste used (Cp—Close Up or Rt—Regenerate), and underwent 100,000 brushing strokes. The profile of each sample was evaluated and the mean wear calculated. The data were analyzed by ANOVA and Tukey tests.
Results:
All bleached groups showed a significant reduction of microhardness in relation to the negative control. The groups treated with remineralizing gels showed a significantly higher microhardness and less wear than the positive control, although nonsignificant differences were observed among them. Nonsignificant differences in ΔE were found among bleached groups. The groups brushed with Regenerate toothpaste showed significantly less wear than those brushed with Close Up toothpaste.
Conclusions:
The remineralizing gels did not interfere with bleaching efficacy. However, all the treatments minimized the surface hardness reduction caused by the bleaching procedure and enamel loss after abrasion. Regenerate toothpaste resulted in less enamel abrasion.
Collapse
|
21
|
An in vitro study on the influence of viscosity and frequency of application of fluoride/tin solutions on the progression of erosion of bovine enamel. Arch Oral Biol 2018; 89:26-30. [DOI: 10.1016/j.archoralbio.2018.01.017] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2017] [Revised: 01/24/2018] [Accepted: 01/25/2018] [Indexed: 11/30/2022]
|
22
|
Bond Stability of a Universal Adhesive System to Eroded/Abraded Dentin After Deproteinization. Oper Dent 2018; 43:291-300. [PMID: 29676982 DOI: 10.2341/16-173-l] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVE Erosive/abrasive challenges can potentially compromise bonding to dentin. Aiming to improve the quality and stability of bonding to this substrate, this study investigated the combined effect of erosion and toothbrush abrasion on the microtensile bond strength (μTBS) stability to dentin using a universal adhesive system in total and self-etching modes, associated or not associated with deproteinization. METHODS Bovine dentin specimens were divided into five groups according to the organic matrix condition (n=20): control (C); erosion (E); erosion + abrasion (EA); erosion + sodium hypochlorite (EH); erosion + abrasion + sodium hypochlorite (EAH). The groups were further divided (n=10) according to the mode of application (total or self-etching) of a universal adhesive. After the bonding procedure, composite blocks were built up, and the samples were cut to obtain sticks for μTBS testing. For each specimen, one-half of the sticks was immediately tested, and the other one-half was tested after artificial aging (5000 thermocycles, 5°C and 55°C). RESULTS Three-way analysis of variance (α=5%) showed a significant difference for the triple interaction ( p=0.0007). Higher μTBS means were obtained for the EH and EAH groups compared with the E and EA groups. The control group showed immediate μTBS values similar to that of the E and EA groups for both bond strategies. CONCLUSIONS Erosion and erosion/abrasion did not significantly influence the immediate μTBS to dentin. Artificial aging reduced μTBS values for the groups C, E, and EA using the total-etching mode. Deproteinization maintained the bond stability to artificially aged eroded and eroded/abraded dentin.
Collapse
|
23
|
Erratum to: Nd:YAG laser irradiation associated with fluoridated gels containing photo absorbers in the prevention of enamel erosion. Lasers Med Sci 2017. [PMID: 28634633 DOI: 10.1007/s10103-017-2248-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
24
|
Nd:YAG laser irradiation associated with fluoridated gels containing photo absorbers in the prevention of enamel erosion. Lasers Med Sci 2017; 32:1453-1459. [PMID: 28500516 DOI: 10.1007/s10103-017-2226-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2016] [Accepted: 04/28/2017] [Indexed: 11/30/2022]
Abstract
This study evaluated the combined effect of Nd:YAG laser irradiation and fluoridated gels containing photo absorbers against enamel erosion. Enamel specimens from bovine teeth were polished, eroded (10 min, with 1% citric acid, pH = 2.6), and randomly allocated into the experimental groups (n = 8), according to the different surface treatments: fluoridated gels (F: 9047 ppm F and F + Sn: 9047 ppm F and 3000 ppm Sn), with or without photo absorbers (E: erythrosine and MB: methylene blue), and associated or not with Nd:YAG laser irradiation (in contact; 0.5 W; 50 mJ; ~41.66 J/cm2; 10 Hz; 40 s; pulse duration of 120 μs). A placebo gel (PLA) associated or not with laser was used as control. All gels had pH = 4.5 and were applied for 2 min. Laser irradiation was performed during gel application. The specimens were then submitted to a 5-day erosion-remineralization cycling model using 0.3% citric acid (pH = 2.6), 4×/day. Enamel surface loss (SL) was analyzed by optical profilometry in the end of the cycling (in μm). Data were analyzed by ANOVA and Tukey tests (α = 0.05). Means (SD) of SL for the groups were the following (different superscript letters imply significant difference among groups): PLA (21.02 ± 1.28)a, PLA + laser (19.20 ± 0.96)ab, laser (17.47 ± 1.50)b, F + Sn + E + laser (13.69 ± 0.62)c, F + E + laser (13.52 ± 1.16)c, F (13.10 ± 1.08)c, F + laser (11.94 ± 1.44)cd, F + Sn + MB + laser (11.90 ± 4.02)cd, F + MB + laser (11.42 ± 1.42)cd, F + Sn (11.12 ± 1.20)cd, and F + Sn + laser (10.35 ± 0.89)d. In conclusion, all fluoridated gels and the Nd:YAG laser irradiation reduced erosion development, but the combination of treatments did not promote further protection. The addition of photo absorbers to the fluoridated gels did not influence the anti-erosive effect of the combination of laser plus fluoridated gels.
Collapse
|
25
|
Abstract
OBJECTIVES The aim of this study was to evaluate microleakage and shear bond strength of composite restorations under different cycling conditions. METHODS AND MATERIALS Class V cavities were prepared in the buccal and lingual surfaces of 30 human molars (n=60). A further 60 molars were used to prepare flat enamel and dentin specimens (n=60 each). Cavities and specimens were divided into six groups and pretreated with an adhesive (self-etch/Clearfil SE Bond or etch-and-rinse/Optibond FL). Composite was inserted in the cavities or adhered to the specimens' surfaces, respectively, and submitted to cycling (control: no cycling; thermal cycling: 10,000 cycles, 5°C to 55°C; thermal/erosive cycling: thermal cycling plus storage in hydrochloric acid pH 2.1, 5 minutes, 6×/day, 8 days). Microleakage was quantified by stereomicroscopy in enamel and dentin margins after immersion in silver nitrate. Specimens were submitted to shear bond strength testing. Statistical analysis was done by two-way analysis of variance and Kruskal-Wallis tests (p<0.05). RESULTS Microleakage in enamel margins was significantly lower in the control group compared with thermal cycling or thermal/erosive cycling. Erosive conditions increased microleakage compared with thermal cycling (significant only for Clearfil SE Bond). No significant differences were observed in dentin margins. Bond strength of enamel specimens was reduced by thermal cycling and thermal/erosive cycling when Clearfil SE Bond was used and only by thermal/erosive cycling when Optibond FL was used. No differences were observed among dentin specimens. CONCLUSIONS Thermal/erosive cycling can adversely affect microleakage and shear bond strength of composite resin bonded to enamel.
Collapse
|
26
|
Adhesive Systems as an Alternative Material for Color Masking of White Spot Lesions: Do They Work? THE JOURNAL OF ADHESIVE DENTISTRY 2016; 18:43-50. [PMID: 26814318 DOI: 10.3290/j.jad.a35518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE To evaluate the color masking effect of infiltration treatment of artificial white spot lesions (AWSL) using a dedicated resin in comparison to different adhesive systems. MATERIALS AND METHODS Enamel/dentin specimens were obtained from bovine incisors and baseline color was assessed using a reflectance spectrophotometer, according to the CIE L*a*b* system. AWSL were produced using a buffered acid solution and a new color evaluation was performed. The specimens were divided into 8 groups: control: artificial saliva changed daily for 7 days; IC: infiltrating resin Icon; EC: EquiaCoat; FU: Futurabond U; SBU: Single Bond U; SBMP: Scotchbond MP; OB: OptibondFL; BF: Bioforty. After the treatments, the color was evaluated again and the values for the parameters ΔL (change in lightness), Δa (change in chroma), Δb (change in hue), and ΔE (general color difference) were calculated in relation to baseline. Data were analyzed by one-way ANOVA and Tukey's tests. RESULTS After treatment, ANOVA showed significant differences for all parameters (p = 0.001). Tukey's test showed the greatest lightness reduction (ΔL) for the IC group, followed by EC, FU, and SBU. The SBMP, OB, and BF groups were similar to the control. For Δb values, all groups showed differences in relation to the control, with no differences between them. In relation to ΔE, all groups showed differences in relation to the control (ΔE = 5.24), with no significant differences between them. ΔE values after application of all resinous materials were lower than the threshold of 3.7, indicating effective color masking. CONCLUSIONS The Icon infiltrant produced a greater lightness reduction of white lesions (ΔL). For general color difference (ΔE), all the resinous materials tested were able to color mask artificial AWSL.
Collapse
|
27
|
Effect of home-bleaching gels modified by calcium and/or fluoride and the application of nano-hydroxyapatite paste on in vitro enamel erosion susceptibility. Acta Odontol Scand 2015; 74:121-6. [PMID: 26083582 DOI: 10.3109/00016357.2015.1053150] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
OBJECTIVE This in vitro study compared the effect of bleaching agents modified by the addition of calcium and/or fluoride and the application of a nano-hydroxyapatite paste after bleaching, on the susceptibility of enamel to erosion. MATERIALS AND METHODS Bovine enamel cylindrical samples (3 mm diameter) were assigned to six groups (n = 20 specimens/group) according to the bleaching agent: no bleaching (C-control), 7.5% hydrogen peroxide gel (HP), HP with 0.5% calcium gluconate (HP+Ca), HP with 0.2% sodium fluoride (HP+F), HP with calcium and fluoride (HP+Ca+F) and HP followed by the application of a nano-hydroxyapatite agent (HP+NanoP). The gels were applied on the enamel surface (1 h) followed by cyclic erosive challenges (Sprite Zero®-2 min), for 14 days. The paste was applied after bleaching for 5 min (HP+NanoP). The enamel surface alteration was measured by contact profilometry (µm) (after 7 and 14 days). RESULTS C-control (mean ± SD: 2.29 ± 0.37 at 7 days/4.86 ± 0.72 at 14 days) showed significantly lower loss compared to the experimental groups. HP+Ca (3.34 ± 0.37/6.75 ± 1.09) and HP+F (4.49 ± 0.92/7.61 ± 0.90) presented significantly lower enamel loss than HP (4.18 ± 0.50/10.30 ± 1.58) only for 14 days and HP+Ca+F (4.92 ± 1.03/8.12 ± 1.52) showed values similar to the HP+F group. The HP+NanoP (5.51 ± 1.04/9.61 ± 1.21) resulted in enamel loss similar to the HP after 14 days. CONCLUSIONS It was found that 7.5% hydrogen peroxide increased the susceptibility of enamel to erosion. The addition of calcium or fluoride to the bleaching gel reduced the erosion effect, while the nano-hydroxyapatite agent did not provide any protective effect.
Collapse
|
28
|
Longitudinal Evaluation of Bond Strength to Enamel of Dental Adhesive Systems Associated with Nd:YAG Laser. Oper Dent 2015; 40:E122-31. [PMID: 25706613 DOI: 10.2341/13-181-l] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVES This study evaluated the durability of bond strength to enamel using total-etch (Single Bond/SB) and self-etch (Clearfil SE Bond/CSEB) adhesives associated with neodymium:yttrium-aluminu-garnet (Nd:YAG) laser irradiation through the uncured adhesives. METHODS Bovine incisors were worn to expose an area of enamel and were divided into four groups: group 1 (control) SB + polymerization; group 2 (control) CSEB + polymerization; group 3 (laser) - SB + Nd:YAG laser (174.16 J/cm(2)) + polymerization; and group 4 (laser) CSEB + Nd:YAG (174.16 J/cm(2)) + polymerization. Blocks of composite were fabricated and stored for 24 hours or 12 months, sectioned into beams, and submitted to microtensile tests. Results were analyzed by three-way analysis of variance (ANOVA) (adhesive, technique, and storage time) and Tukey tests. RESULTS ANOVA revealed significant differences for adhesive × technique and technique × storage time (p<0.05). The mean values (MPa) for interaction adhesive × technique (standard deviation) were as follows: SB/control = 35.78 (6.04)a; SB/laser = 26.40 (7.25)b, CSEB/control = 26.32 (5.71)b, CSEB/laser = 23.90 (7.49)b. For interaction technique × storage time the mean values were as follows: control/24 hours = 32.58 (6.49)a; control/12 months = 29.52 (8.38)a; laser/24 hours = 29.37 (5.71)a; laser/12 months = 20.92 (6.5)b. Groups with the same letters showed no statistically significant differences. CONCLUSION Scanning electron microscope analysis showed evident areas of micromorphological alterations in lased samples after 12 months of water storage. Nd:YAG laser irradiation of enamel through unpolymerized total-etch adhesive significantly reduced bond strength compared with the control. Bond strength decreased when enamel samples irradiated with Nd:YAG laser through unpolymerized adhesives were stored in water for 12 months.
Collapse
|
29
|
Abstract
ABSTRACT
Objective
The aim of this study was to evaluate the effect of chemical degradation media associated with brushing on surface roughness (Ra) and Knoop microhardness (KHN) analyses of different composites.
Materials and methods
Eighty specimens were prepared for each composite: GrandioSO (Voco), Amaris (Voco), Filtek Supreme (3M ESPE), Filtek LS (3M ESPE). The specimens were divided into four groups according to the immersion in chemical degradation media for 7 days: artificial saliva (control), heptane, 0.02 M citric acid, 70% ethanol. The surface of specimens was submitted to 10950 brushing cycles (200 gm load) in an automatic toothbrushing machine with abrasive slurry. Surface roughness and microhardness measurements were obtained at baseline, after immersion in chemical degradation media and after brushing. Data were submitted to three-way repeated measures ANOVA and Tukey's test (p < 0.05).
Results
The KHN means for composites were: Grandio (153.5 ± 35.9)a, Filtek Supreme (87.0 ± 24.9)b, Amaris (64.5 ± 24.5)c, LS (69.0 ± 15.3)c; for storage media: artificial saliva (97.3 ± 46.7)a, ethanol (93.3 ± 49.9)a, citric acid (95.8 ± 42.1)a, heptane (87.6 ± 36.7)b; and after treatments: after chemical degradation (104.8 ± 49.7)a, baseline (93.8 ± 42.5)b, after brushing (81.9 ± 36.5)c. The Ra results for composites were: LS (0.15 ± 0.25)a, GrandioSO (0.19 ± 0.24)ab, Filtek Supreme (0.20 ± 0.22)ab, Amaris (0.23 ± 0.37)b; for storage media: artificial saliva (0.18 ± 0.31)a, heptane (0.18 ± 0.25)a, ethanol (0.20 ± 0.26)a, citric acid (0.21 ± 0.28)a, and after treatments: brushing (0.11 ± 0.14)a, after chemical degradation (0.23 ± 0.32)b, baseline (0.24 ± 0.32)b.
Conclusion
Brushing after chemical degradation reduced surface roughness values. In general, chemical degradation did not affect composites roughness, but microhardness was significantly reduced. Heptane produced the biggest reduction in composites microhardness.
Clinical relevance
The food-simulating solutions and brushing simulating alter the composites properties, and these alterations are material-dependent.
How to cite this article
Torres CRG, Da Silva TM, Sales ALLS, Pucci CR, Borges AB. Influence of Chemical Degradation and Toothbrushing on Surface of Composites. World J Dent 2015;6(2):65-70.
Collapse
|
30
|
Abstract
SUMMARY
Objective
To evaluate the influence of pH on the bleaching effect of hydrogen peroxide on chromogen agents.
Method
Hydrogen peroxide 50% was mixed with red wine or with an alcoholic solution of tobacco in glass cuvettes, resulting in final peroxide concentrations of 16.97% and 21.12%, respectively. The pH of this mixture was measured and adjusted with 3.3 M HCl solution or 2.5 M NaOH solution to obtain the final pH values of 3.0, 4.0, 5.0, 6.0, 7.0, 8.0, and 9.0. After mixing, the color of these solutions was evaluated in a reflectance spectrophotometer; readings were repeated after 10 minutes for the wine solution and 20 minutes for the tobacco solution. Ten samples were prepared for each solution at each pH. Color changes (Delta E) were calculated. The data were statistically analyzed using analysis of variance one-way and Tukey tests, with a significance level of 5%.
Results
There were significant differences among the different pH values for the wine and tobacco solutions (p=0.0001). The Tukey test showed that for both solutions, pH 9.0 resulted in a significantly greater bleaching effect than the other values tested.
Conclusion
The efficacy of hydrogen peroxide bleaching is directly proportional to the increase in its pH.
Collapse
|
31
|
The Effect of Three Desensitizing Agents on Dentin Hypersensitivity: A Randomized, Split-mouth Clinical Trial. Oper Dent 2014; 39:E186-94. [DOI: 10.2341/13-057] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
The aim of this study was to evaluate the efficacy of three desensitizing agents to provide relief to dentin hypersensitivity after one session in a four-week follow-up. Forty selected patients participated in a double-blind study following a split-mouth model. One application of the desensitizing agents (A, Admira Protect [Voco]; B, Bifluorid 12 [Voco]; and C, Colgate Pro-Relief in office [Colgate Palmolive]) was performed in three different quadrants for each patient. Each tooth was evaluated by tactile and evaporative stimuli, and the sensitivity response was measured using the Visual Analogue Scale. Evaluations were performed at baseline, immediately after treatment, and after one, two, three, and four weeks. The application of Kruskal-Wallis and Dunn multiple comparisons tests (5%) for both tactile and evaporative stimuli showed that all agents presented a significant desensitizing effect. In groups A and B this relief was maintained for four and three weeks, respectively, as measured by tactile stimulus and for four weeks with evaporative stimulus. The desensitizing effect for group C was maintained for two weeks for both tactile and evaporative stimuli. It is concluded that all desensitizing agents tested were effective in reducing sensitivity compared to baseline values. One application of Admira Protect and Bifluorid 12 presented a longer-lasting desensitizing effect than did Colgate Pro-Relief (applied in the office) on both tactile and evaporative stimuli.
Collapse
|
32
|
Abstract
OBJECTIVES The aim of this study was to investigate the effect of hydrogen peroxide gels with different concentrations (20%, 25%, 30%, and 35%) on enamel Knoop microhardness (KNH) as well as on changes in dental color (C). METHODS Cylindrical specimens of enamel/dentin (3-mm diameter and 2-mm thickness) were obtained from bovine incisors and randomly divided into six groups (n=20), according to the concentration of the whitening gel (20%, 25%, 30%, 35%, control, thickener). After polishing, initial values of KNH0 and color measurement, assessed by spectrophotometry using the CIE L*a*b* system, were taken from the enamel surface. The gels were applied on the enamel surface for 30 minutes, and immediate values of KNHi were taken. After seven days of being stored in artificial saliva, new measures of KNH7 and color (L7* a7* b7*, for calculating ΔE, ΔL, and Δb) were made. Data were submitted to statistical analysis of variance, followed by Tukey test (p<0.05). RESULTS Differences in gel concentration and time did not influence the microhardness (p=0.54 and p=0.29, respectively). In relation to color changes, ΔE data showed that the 35% gel presented a higher color alteration than the 20% gel did (p=0.006). CONCLUSION Bleaching with 35% hydrogen peroxide gel was more effective than with the 20% gel, without promoting significant adverse effects on enamel surface microhardness.
Collapse
|
33
|
Abstract
Developmental defects involving color alteration of enamel frequently compromise the esthetic appearance of the tooth. The resin infiltration technique represents an alternative treatment for color masking of these lesions and uniformization of tooth color. This technique is considered relatively simple and microinvasive, since only a minimal portion of enamel is removed. This article illustrates the color-masking effect with resin infiltration of fluorosis and traumatic hypomineralization lesions with a case series. The final esthetic outcomes demonstrated the ability of the resin infiltrant to mask the color of white developmental defect lesions, resulting in satisfactory clinical esthetic improvements. However, in more severe cases, the color-masking effect was not complete.
Collapse
|
34
|
Impact of Quantity of Resin, C-factor, and Geometry on Resin Composite Polymerization Shrinkage Stress in Class V Restorations. Oper Dent 2014; 39:144-51. [DOI: 10.2341/12-440-l] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objective
This study evaluated the effect of quantity of resin composite, C-factor, and geometry in Class V restorations on shrinkage stress after bulk fill insertion of resin using two-dimensional finite element analysis.
Methods
An image of a buccolingual longitudinal plane in the middle of an upper first premolar and supporting tissues was used for modeling 10 groups: cylindrical cavity, erosion, and abfraction lesions with the same C-factor (1.57), a second cylindrical cavity and abfraction lesion with the same quantity of resin (QR) as the erosion lesion, and then all repeated with a bevel on the occlusal cavosurface angle. The 10 groups were imported into Ansys 13.0 for two-dimensional finite element analysis. The mesh was built with 30,000 triangle and square elements of 0.1 mm in length for all the models. All materials were considered isotropic, homogeneous, elastic, and linear, and the resin composite shrinkage was simulated by thermal analogy. The maximum principal (MPS) and von Mises stresses (VMS) were analyzed for comparing the behavior of the groups.
Results
Different values of angles for the cavosurface margin in enamel and dentin were obtained for all groups and the higher the angle, the lower the stress concentration. When the groups with the same C-factor and QR were compared, the erosion shape cavity showed the highest MPS and VMS values, and abfraction shape, the lowest. A cavosurface bevel decreased the stress values on the occlusal margin. The geometry factor overcame the effects of C-factor and QR in some situations.
Conclusion
Within the limitations of the current methodology, it is possible to conclude that the combination of all variables studied influences the stress, but the geometry is the most important factor to be considered by the operator.
Collapse
|
35
|
Abstract
<p><strong>Objective: </strong>The aim of this study was to evaluatethe surface roughness of indirect composites afterpolishing with aluminum oxide (Al2O3) discs. <strong>Materialand Methods</strong>: One-hundred and eighty specimenswere confectioned with 6 indirect composites using aprefabricated matrix, resulting in six groups (n-30):Group SO - Solidex, Group SI - Signum, Group SF- Sinfony, Group OP - Opallis; Group RE - Resilab,Group EP - Epricord, Group AD - Adoro. Each groupwas divided into three subgroups according to thepolishing (n-10): Subgroup C (Control) - withoutpolishing (polyester strip); Subgroup S - polishingwith Sof-Lex discs; Subgroup T - polishing with TDVdiscs. The surface roughness was measured with aprofilometer. <strong>Results: </strong>The results were analyzed byANOVA and Tukey tests (5%), resulting in p = 0.00.The mean values (±standard-deviation) measured inRa (μm) for each Group/Subgroup were: RE/C - 0.14(± 0.14) a; EP/C - 0.18 (± 0.46) ab; SO/C - 0.24 (±0.22) abc; SF/S - 0.24 (± 0.17) abc; SF/C - 0.26 (±2.54)abc; SI/C - 0.30 (± 0.34)abcd; SO/T - 0.33(±0.42) abcd; AD/S - 0.34(± 0.88)abcd; AD/C - 0.37(±0.60)ab; SI/S - 0.37(± 1.39)bcd; SO/S - 0.43(± 0.26)cd; EP/S – 0.44 (± 1.02) cd; RE/S - 0.54(±2.02) de;SI/T - 0.65(± 0.88)ef; RE/T - 0.83 (± 0.54) fg; SF/T- 0.85 (± 0.21) fg; AD/T - 0.88 (± 1.74) fg; EP/T- 0.91(± 0.89) g. <strong>Conclusion: </strong>It is concluded thatpolyester strip resulted in significantly lowest surfaceroughness; polishing with TDV discs resulted insignificantly higher surface roughness compared toSof-Lex discs and that the surface roughness resultsdepend on the composite tested.</p><p>Keywords<br />Composite resins; Dental polishing; Biofilms.</p>
Collapse
|
36
|
Color Stability of Resin Used for Caries Infiltration After Exposure to Different Staining Solutions. Oper Dent 2013. [DOI: 10.2341/13-150] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
37
|
Effect of remineralizing agents on the bleaching efficacy of gels. GENERAL DENTISTRY 2013; 61:67-71. [PMID: 24192737] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Adding remineralizing agents to bleaching gels has been proposed to reduce the mineral loss of enamel and tooth sensitivity. This study sought to investigate the efficacy of hydrogen peroxide (HP) gel after the addition of calcium and fluoride. Ninety enamel-dentin discs were prepared from bovine incisors. The specimens were divided into 3 groups: a negative control group (nonbleached) and 2 experimental groups, 1 bleached with 7.5% HP (at-home bleaching) and the other with 35% HP (in-office bleaching). Each group was subdivided into 3 subgroups, according to the addition of remineralizing agents on gels: no remineralizing agents, addition of 2% calcium gluconate, and addition of 2% sodium fluoride. For 14 days, the gels were applied 1 hour/day for at-home bleaching and 50 minutes/week for in-office bleaching. Between bleaching, the specimens were immersed in artificial saliva. The results showed significant differences in all bleached groups compared to the nonbleached negative control group. No significant differences were observed for any parameters tested when the different treatments were compared using 2-way ANOVA. It was concluded that adding remineralizing agents to the gels did not interfere with their whitening effect and that both concentrations tested offered similar bleaching outcomes.
Collapse
|
38
|
A comparison of methods used to determine chewing side preference in deciduous, mixed and permanent dentitions. BRAZILIAN DENTAL SCIENCE 2013. [DOI: 10.14295/bds.2013.v16i1.870] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Objective: The purpose of this study was to determine whether ‘chewing side preference’ (CSP) is correlated to ‘chewing side preference during the first chewing cycle’ (CSP1ºC) in the deciduous, mixed and permanent dentitions.Methods: Three-hundred subjects were divided in 3 groups: Group 1 – 100 children 3-5 years old, primary dentition; Group 2 – 100 children 6-12 years old, mixed dentition; Group 3 – 100 subjects 18-47 years old, permanent dentition. CSP was determined using a method developed by McDonnell et al. (2004). Subjects were given a piece of gum and the position of the chewing gum was recorded 7 times as right or left. Subjects were classified as ‘observed preferred chewing side’ (OPCS) when they performed 5/7, 6/7 or 7/7 strokes on the same side. OPCS corresponded to the CSP. CSP1ºC was determined using a method developed by Hoogmartens and Caubergh (1987). Subjects were given five pieces of gum and the position of the chewing gum at first chewing cycle was recorded as right or left. For each subject, an index (I) was performed. The Chi-square (X2) and phi correlation (r) tests were used to investigate signi?cant correlations between CSP and CSP1ºC. Results: There was a strong positive and significant correlation between CSP and CSP1ºC for primary dentition (p=0.000; r=0.82), for mixed dentition (p=0.000; r=0.81) and a very strong positive and significant correlation for permanent dentition (p=0.000; r=0.90). Conclusion: CSP can be significantly correlated to CSP1ºC for primary dentition, mixed dentition and permanent dentition, and these are strong positive relationships for primary and mixed dentitions and very strong positive relationship for permanent dentition.
Collapse
|
39
|
Influence of glass fiber reinforcement and resin viscosity on the fracture strength of adhesive partial fixed prosthetic dentures. BRAZILIAN DENTAL SCIENCE 2013. [DOI: 10.14295/bds.2013.v16i1.854] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
O objetivo deste estudo foi avaliar a influência do reforço com fibra de vidro e viscosidade da resina na resistência à fratura de prótese parcial fixa adesiva (PPFA). Um molde de aço inoxidável foi confeccionado simulando preparos oclusais para PPFA em primeiro pré-molar superior (4x4x2mm) e molar (6x4x2mm), com uma caixa proximal (2x1x4mm) e 7mm de distância entre eles. Esses moldes foram duplicados em poliuretano (n = 60) e divididos em dois grupos de acordo com a viscosidade da resina: G - Grandio SO (VOCO) (n= 30) e GHF - Grandio SO Heavy flow (VOCO) (n= 30). Estes grupos foram subdivididos em três subgrupos de acordo com o reforço de fibra de vidro utilizado (n = 10): Subgrupo N - sem reforço de fibra de vidro; Subgrupo V - GRANDTEC (VOCO); subgrupo S – everStick C & B (Stick Tech). Quatro incrementos divididos em 2 camadas, 2 na parte inferior e 2 na parte superior dos preparos foram fotopolimerizados de acordo com as instruções dos fabricantes. Uma força vertical foi aplicada no centro das peças a uma velocidade de 1mm/min. Os dados foram obtidos em Kgf e submetidos a ANOVA a 2 fatores e teste de Tukey (? = 0,05). A ANOVA mostrou diferenças significativas para reforço de fibra de vidro. Subgrupo N (24,45 ± 3,60)a foi significativamente diferente do subgrupo S (32,54 ± 6,94)b e subgrupo V (37,18 ± 5,33)c. As fibras de vidro testadas foram capazes de melhorar a resistência à fratura de PPFA. A Fibra GRANDTEC apresentou os maiores valores de resistência à fratura e, para as resinas estudadas, a viscosidade não teve influência na resistência à fratura de PPFA .
Collapse
|
40
|
Abstract
SUMMARY
Objectives
People increasingly desire tooth whitening. Considering the wide range of whitening products on the market, this study evaluated the efficacy of whitening toothpastes and mouth rinses compared with the 10% carbamide peroxide (CP) whitening gel.
Methods
We obtained 120 cylindrical specimens from bovine teeth, which were darkened for 24 hours in a coffee solution. The color measurement was performed by a spectrophotometer using the CIE L*a*b* system, and specimens were divided into six groups according to the use of the following agents: group 1, conventional fluoridated toothpaste; group 2, Close Up White Now; group 3, Listerine Whitening; group 4, Colgate Plax Whitening; group 5, experimental mouth rinse with Plasdone; and group 6, 10% CP Whiteness Perfect. After the simulation of 12 weeks of treatment for groups 1 to 5 and 14 days of treatment for group 6, the specimens were subjected to a new color reading.
Results
Data were subjected to one-way analysis of variance (α=0.05), which showed significant differences among groups after 12 weeks for ΔE (p=0.001). Results of the Tukey test revealed that groups 3, 4, and 6 presented significantly higher color alteration than groups 1, 2, and 5.
Conclusions
The whitening toothpaste Close Up White Now and the experimental mouth rinse with Plasdone showed similar color alteration as conventional toothpaste after a 12-week treatment simulation. These groups presented significantly lower color alteration compared with whitening mouth rinses Listerine and Colgate Plax Whitening, which showed similar results to those observed after 14 days of bleaching with 10% CP treatment.
Collapse
|
41
|
Influence of Nd:YAG or Er:YAG laser surface treatment on microtensile bond strength of indirect resin composites to resin cement. Lasers surface treatment of indirect resin composites. THE EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY 2012; 20:135-140. [PMID: 23101180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
This study evaluated the influence of the surface pretreatment of indirect resin composite (Signum, Admira Lab and Sinfony) on the microtensile bond strength of a resin cement. Sixty samples made of each brand were divided into 6 groups, according to surface treatment: (1) control; (2) controlled-air abrasion with Al2O3; (3) Er:YAG Laser 200 mJ, 10 Hz, for 10s; (4) Er: YAG Laser 300 mJ, 10 Hz, for 10 s; (5) Nd:YAG 80 mJ, S15Hz for 1 min; (6) Nd:YAG 120mJ, 15 Hz for 1 min. After treatments, all the groups received an application of 37% phosphoric acid and adhesive. The pair of blocks of the same brand were cemented to each other with dual resin cement. The blocks were sectioned to obtain resin-resin sticks (1 x1 mm) and analyzed by microtensile bond testing. The bond strength values were statistically different, irrespective of the surface treatment performed, with highest values for Sinfony (43.81 MPa) and lowest values for Signum (32.33 MPA). The groups treated with the Nd:YAG laser showed the lowest bond strength values and power did not interfere in the results, both for Nd:YAG laser and Er:YAG. Controlled-air abrasion with Al203 is an efficient surface treatment method and the use of the Nd:YAG and Er:YAG lasers reduced bond strength, irrespective of the intensity of energy used.
Collapse
|
42
|
Influence of Hydrogen Peroxide Bleaching Gels on Color, Opacity, and Fluorescence of Composite Resins. Oper Dent 2012; 37:526-31. [DOI: 10.2341/11-189-l] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
The aim of the present study was to evaluate the effect of 20% and 35% hydrogen peroxide bleaching gels on the color, opacity, and fluorescence of composite resins. Seven composite resin brands were tested and 30 specimens, 3-mm in diameter and 2-mm thick, of each material were fabricated, for a total of 210 specimens. The specimens of each tested material were divided into three subgroups (n=10) according to the bleaching therapy tested: 20% hydrogen peroxide gel, 35% hydroxide peroxide gel, and the control group. The baseline color, opacity, and fluorescence were assessed by spectrophotometry. Four 30-minute bleaching gel applications, two hours in total, were performed. The control group did not receive bleaching treatment and was stored in deionized water. Final assessments were performed, and data were analyzed by two-way analysis of variance and Tukey tests (p<0.05). Color changes were significant for different tested bleaching therapies (p<0.0001), with the greatest color change observed for 35% hydrogen peroxide gel. No difference in opacity was detected for all analyzed parameters. Fluorescence changes were influenced by composite resin brand (p<0.0001) and bleaching therapy (p=0.0016) used. No significant differences in fluorescence between different bleaching gel concentrations were detected by Tukey test. The greatest fluorescence alteration was detected on the brand Z350. It was concluded that 35% hydrogen peroxide bleaching gel generated the greatest color change among all evaluated materials. No statistical opacity changes were detected for all tested variables, and significant fluorescence changes were dependent on the material and bleaching therapy, regardless of the gel concentration.
Collapse
|
43
|
Effect of Caries Infiltration Technique and Fluoride Therapy on Microhardness of Enamel Carious Lesions. Oper Dent 2012; 37:363-9. [DOI: 10.2341/11-070-l] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Enamel white spot subsurface lesions compromise esthetics and precede cavitation; therefore, they must be halted. The aim of this study was to evaluate the effect of a caries infiltration technique and fluoride therapy on the microhardness of enamel carious lesions. Subsurface carious lesions were produced in 60 bovine specimens with polished enamel surfaces. The specimens were divided into four groups (n=15), according to the treatment used: CON, control—immersion in artificial saliva; DF, daily 0.05% fluoride solution; WF, weekly 2% fluoride gel; and IC, resin infiltration (Icon). The specimens were kept in artificial saliva and evaluated for microhardness at five points: baseline, after caries production, after four and eight weeks of treatment, and a final evaluation after being submitted to a new acid challenge. The repeated-measures analysis of variance showed significant differences according to the type of treatment (TREAT; p=0.001) and time of evaluation (EV; p=0.001). The results of the Tukey test were TREAT: CON = 45.18 (±29.17)a, DF = 107.75 (±67.38)b, WF = 83.25 (±51.17)c, and IC = 160.83 (±91.11)d. Analysis of correlation between the TREAT and EV factors showed no significant differences for DF (138.63 ± 38.94) and IC (160.99 ± 46.13) after the new acid challenge. The microhardness results in decreasing order after eight weeks were IC > DF > WF > CON. It was concluded that the microhardness of carious lesions increased with the infiltration of resin, while the final microhardness after a new acid challenge was similar for DF and IC.
Collapse
|
44
|
Dentin Hypersensitivity—Etiology, Treatment Possibilities and Other Related Factors: A Literature Review. ACTA ACUST UNITED AC 2012. [DOI: 10.5005/jp-journals-10015-1129] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
ABSTRACT
Dentinal hypersensitivity is a common painful condition of the teeth, associated with the exposure of the dentin to external environment of the mouth. However, little is known about the etiology and predisposing factors, which can compromise management. The aim of this paper is to summarize existing information about epidemiology, mechanisms, etiology, differential diagnosis and treatment.
Clinical relevance
A better understanding of the etiology and factors involved in dentin hypersensitivity will help the management of the hypersensitivity teeth.
How to cite this article
Borges AB, Barcellos DC, Torres CRG, Borges ALS, Marsilio AL, Carvalho CAT. Dentin Hypersensitivity— Etiology, Treatment Possibilities and Other Related Factors: A Literature Review. World J Dent 2012;3(1):60-67.
Collapse
|
45
|
A new intraoral device to facilitate preparation of the guide plane for removable dental prostheses. GENERAL DENTISTRY 2012; 60:e13-e16. [PMID: 22313987] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
This article presents a prototype of an intraoral device that facilitates preparation of parallel guide planes with accuracy and minimal occlusal divergence. The design of this device facilitates transfer of the desired path of insertion from the diagnostic cast to the mouth quickly and efficiently.
Collapse
|
46
|
Prevalence of chewing side preference in the deciduous, mixed and permanent dentitions. J Contemp Dent Pract 2011; 12:339-42. [PMID: 22269193 DOI: 10.5005/jp-journals-10024-1056] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
AIM This study evaluated the prevalence of the chewing side preference (CSP) in the deciduous, mixed and permanent dentitions. MATERIALS AND METHODS Three-hundred subjects were divided in three groups (n = 100): Group 1 - children with deciduous dentition; group 2-children with mixed dentition; group 3 - subjects with permanent dentition. The CSP was determined using a direct method (visual observation) developed by McDonnell et al. (2004). Descriptive statistic was used to observe the prevalence of CSP. The Pearson's Chi-square was used to investigate signicant associations between gender, presence of CSP and preferred side (right/left). RESULTS AND CONCLUSION Eighty-seven percent of group 1 had a CSP. Eighty-two percent of group 2 had a CSP. Seventy-six percent of group 3 had a CSP. There was no statistically significant association between presence of CSP and gender in all groups. There was no statistically significant association between preferred side (right/left) and gender in all groups. CLINICAL SIGNIFICANCE There is a higher prevalence of subjects in deciduous, mixed and permanent dentition that presented chewing side preference. The early diagnosis of the presence of chewing side preference can prevent the unilateral chewing pattern with prophylactic therapy applied to the first teeth (deciduous).
Collapse
|
47
|
Assessment of the effectiveness of light-emitting diode and diode laser hybrid light sources to intensify dental bleaching treatment. Acta Odontol Scand 2011; 69:176-81. [PMID: 21250920 DOI: 10.3109/00016357.2010.549503] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
OBJECTIVE To evaluate the effectiveness of the color change of hybrid light-emitting diode (LED) and low-intensity infrared diode laser devices for activating dental bleaching and to verify the occurrence of a color regression with time. MATERIAL AND METHODS A total of 180 specimens obtained from human premolars were immersed in a coffee solution for 15 days for darkening and then divided into eight experimental groups (n = 20 in each) as follows: G1, bleaching without light; G2, bleaching with halogen light; G3, bleaching with a blue LED (1000 mW/470 nm) and a laser device (120 mW/795 nm) simultaneously; G4, bleaching with an LED emitting blue light (1000 mW/470 nm); G5, bleaching with a blue LED (800 mW/470 nm) and a laser device (500 mW/830 nm) simultaneously; G6, bleaching with a blue LED device (800 mW); G7, bleaching with a green LED (600 mW/530 nm) and a laser device (120 mW/795 nm) simultaneously; and G8, bleaching with a green LED (600 mW). Three measurements were performed (at baseline and 14 days and 12 months after bleaching) using a Vita Easyshade spectrophotometer. The data were submitted to two-way ANOVA and a Tukey test. RESULTS All groups showed significantly higher ΔE values than Group G1, with the exception of Group G8. Variations in the ΔE values at 14 days were significant when compared with those obtained at baseline and after 12 months. CONCLUSIONS Light activation of the bleaching gel provided faster and more intense bleaching than use of the bleaching gel without light activation. Combinations of low-intensity diode lasers are ineffective as a bleaching gel activator. Color regression was observed after 12 months of storage.
Collapse
|
48
|
Effect of caries infiltration technique and fluoride therapy on the colour masking of white spot lesions. J Dent 2011; 39:202-7. [DOI: 10.1016/j.jdent.2010.12.004] [Citation(s) in RCA: 103] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2010] [Revised: 12/08/2010] [Accepted: 12/10/2010] [Indexed: 11/27/2022] Open
|
49
|
The Influence of Chemical Activation on Tooth Bleaching Using 10% Carbamide Peroxide. Oper Dent 2011; 36:162-8. [DOI: 10.2341/09-280-l] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Clinical Relevance
If a chemical agent were able to accelerate the effects of bleaching agents on tooth structure, one could reduce treatment time or diminish the daily time spent on the bleaching procedures.
Collapse
|
50
|
Abstract
OBJECTIVES This study aimed to measure pH changes during 14 days intracoronal bleaching with hydrogen peroxide/sodium perborate and carbamide peroxide/sodium perborate. MATERIALS AND METHODS Twenty patients presenting endodontically treated central maxillary incisors with color alterations were divided in two groups (n = 10): Group CP + SP: 37% carbamide peroxide + sodium perborate paste; Group HP + SP: 30% hydrogen peroxide + sodium perborate paste. The pH values were measured using a digital microprocessor at different times: Baseline, 2, 7 and 14 days. Data were analyzed with two-way ANOVA followed by Tukey's test (α = 0.05). RESULTS ANOVA showed p < 0.00 which indicated significant difference between the groups. The mean values (± sd) and the results of the Tukey´s test were: HP + SP/14 days-7.98 (±0.58)a; HP + SP/7 days-8.59 (±0.18)b; HP + SP/2 days- 8.83 (±0.32)bc; HP + SP/Baseline-8.83 (±0.01)bc; CP + SP/ Baseline-8.89 (±0.01)bc; CP + SP/14 days-9.11 (±0.58)cd; CP + SP/7 days-9.54 (±0.16)de; CP + SP/2 days-9.66 (±0.08) de. The group HP + SP resulted in significantly lower pH values compared with group CP + SP. CONCLUSION It can be concluded that both associations showed alkaline pH values; however, there was significant reduction in the pH values of the 30% hydrogen peroxide associated with sodium perborate after 14 days. CLINICAL SIGNIFICANCE The association of hydrogen peroxide and carbamide peroxide with sodium perborate paste presented alkaline characteristics during the 14-day evaluated period. Thus, regarding pH changes, both associations can be considered safe as intracoronal bleaching agents.
Collapse
|