1
|
Reliability of signal intensity in the basal ganglia on non-contrast T1-weighted MR scans after repetitive application of a gadolinium-based contrast agent in pediatric neuro-oncology patients. Eur J Radiol 2023; 169:111179. [PMID: 37949021 DOI: 10.1016/j.ejrad.2023.111179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Accepted: 10/29/2023] [Indexed: 11/12/2023]
Abstract
PURPOSE To evaluate the reliability of signal intensity (SI) changes in the basal ganglia as a supposed indicator of gadolinium deposition in the brain after repetitive application of gadolinium-based contrast agents (GBCAs) in a pediatric neuro-oncological collective. METHODS One hundred and eight neuropediatric patients (54 male, 54 female, 0-17 years old), with repetitive GBCA-enhanced cranial MRIs between 2003 and 2017, were retrospectively analyzed. Two radiologists measured SI in the nucleus dentatus (ND), globus pallidus (GP), thalamus (T), and the pons (P). The NDP and GPT ratio were calculated. An intraclass correlation coefficient, and multiple linear regressions with subsequent stepwise backward variable selection were performed to evaluate the influence of gender, patient's age at the first MRI, time interval between the first and last MRI, linear or macrocyclic GBCAs, residual pathology, treatments, and magnet field strengths. RESULTS The inter-reader agreement was good for GPT and NDP in the whole collective (ICC = 0.837 and ICC = 0.793) and for children >2 years of age (ICC = 0.874 and ICC = 0.790), but poor to moderate for children ≤2 years of age (ICC = 0.397 and ICC = 0.748). The intra-reader agreement was good (ICC = 0.910 and ICC = 0.882). An SI increase was only observed for both readers in GPT (p = 0.003, or p < 0.001). None of the considered cofactors showed a consistent effect on SI changes for either readers or regions. CONCLUSION Measurements of SI changes in the basal ganglia are not a reliable parameter with which to evaluate or estimate gadolinium deposition in the brain or to identify suspicious influential factors after repeated GBCA applications.
Collapse
|
2
|
PM/Scl-Overlap-Syndrom bei einem 14-jährigen Mädchen nach SARS-CoV-2-Infektion. J Dtsch Dermatol Ges 2023; 21:661-663. [PMID: 37338839 DOI: 10.1111/ddg.15044_g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Accepted: 02/06/2023] [Indexed: 06/21/2023]
|
3
|
PM/Scl overlap syndrome in a 14-year-old girl manifesting after a SARS-CoV-2 infection. J Dtsch Dermatol Ges 2023. [PMID: 37259704 DOI: 10.1111/ddg.15044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Accepted: 02/06/2023] [Indexed: 06/02/2023]
|
4
|
Relative Enhancement in Gadoxetate Disodium-Enhanced Liver MRI as an Imaging Biomarker in the Diagnosis of Non-Alcoholic Fatty Liver Disease in Pediatric Obesity. Nutrients 2023; 15:nu15030558. [PMID: 36771265 PMCID: PMC9921256 DOI: 10.3390/nu15030558] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Revised: 01/16/2023] [Accepted: 01/17/2023] [Indexed: 01/24/2023] Open
Abstract
Relative enhancement (RE) in gadoxetate disodium (Gd-EOB-DTPA)-enhanced MRI is a reliable, non-invasive method for the evaluation and differentiation between simple steatosis and non-alcoholic steatohepatitis in adults. This study evaluated the diagnostic accuracy of RE in Gd-EOB-DTPA-enhanced liver MRI and hepatic fat fraction (HFF) in unenhanced liver MRI and ultrasound (US) for non-alcoholic fatty liver disease (NAFLD) screening in pediatric obesity. Seventy-four liver US and MRIs from 68 pediatric patients (13.07 ± 2.95 years) with obesity (BMI > BMI-for-age + 2SD) were reviewed with regard to imaging biomarkers (liver size, volume, echogenicity, HFF, and RE in Gd-EOB-DTPA-enhanced MRIs, and spleen size), blood biomarkers, and BMI. The agreement between the steatosis grade, according to HFF in MRI and the echogenicity in US, was moderate. Alanine aminotransferase correlated better with the imaging biomarkers in MRI than with those in US. BMI correlated better with liver size and volume on MRI than in US. In patients with RE < 1, blood biomarkers correlated better with RE than those in the whole sample, with a significant association between gamma-glutamyltransferase and RE (p = 0.033). In conclusion, the relative enhancement and hepatic fat fraction can be considered as non-invasive tools for the screening and follow-up of NAFLD in pediatric obesity, superior to echogenicity on ultrasound.
Collapse
|
5
|
Risk Scores for Metabolic Dysfunction-Associated Fatty Liver Disease in Pediatric Obesity. ANNALS OF NUTRITION & METABOLISM 2022; 78:247-254. [PMID: 35933983 DOI: 10.1159/000526373] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Accepted: 07/28/2022] [Indexed: 06/15/2023]
Abstract
INTRODUCTION Early noninvasive detection of incipient liver damage is crucial to prevent long-term adverse health outcomes. A variety of scores to assess liver status have been proposed, mostly for adult populations. Validation of noninvasive hepatic scores to identify children at risk of metabolic dysfunction-associated fatty liver disease (MAFLD) is a gap in research, particularly in youth with severe obesity considering pubertal stage and sex. METHODS In a well-characterized pediatric population aged 9-19 years (n = 115), 19 published liver scores were analyzed. The area under the receiver operating characteristic curve (AUROC) for determination of MAFLD as assessed by magnetic resonance imaging was calculated. RESULTS The pediatric indices PNFI, B-AST, and M-APRI and several scores developed in adults significantly differed in children with MAFLD compared to children without, while some established indices did not. Only nonalcoholic fatty liver disease liver fat score (NAFLD-LFS) and the model by Cao et al. [PLoS One. 2013;8(12):e82092] showed acceptable predictive accuracy (AUROC >0.8) independently of pubertal stage and sex. When stratifying for pubertal stage and sex, the GSG-Index was superior in pubertal girls, and NAFLD-LFS performed best in pubertal boys. CONCLUSION NAFLD-LFS and the model by Cao et al. [PLoS One. 2013;8(12):e82092] were well suited to predict MAFLD in youth with severe obesity. In pubertal children, GSG-Index and NAFLD-LFS performed best in girls and boys, respectively.
Collapse
|
6
|
Influence of age on gadoxetic acid disodium-induced transient respiratory motion artifacts in pediatric liver MRI. PLoS One 2022; 17:e0264069. [PMID: 35235594 PMCID: PMC8890729 DOI: 10.1371/journal.pone.0264069] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2021] [Accepted: 02/02/2022] [Indexed: 11/27/2022] Open
Abstract
Purpose Gd-EOB-DTPA-enhanced liver MRI is frequently compromised by transient severe motion artifacts (TSM) in the arterial phase, which limits image interpretation for the detection and differentiation of focal liver lesions and for the recognition of the arterial vasculature before and after liver transplantation. The purpose of this study was to investigate which patient factors affect TSM in children who undergo Gd-EOB-DTPA-enhanced liver MRI and whether younger children are affected as much as adolescents. Methods One hundred and forty-eight patients (65 female, 83 male, 0.1–18.9 years old), who underwent 226 Gd-EOB-DTPA-enhanced MRIs were included retrospectively in this single-center study. The occurrence of TSM was assessed by three readers using a four-point Likert scale. The relation to age, gender, body mass index, indication for MRI, requirement for sedation, and MR repetition was investigated using uni- and multivariate logistic regression analysis. Results In Gd-EOB-DTPA-enhanced MRIs, TSM occurred in 24 examinations (10.6%). Patients with TSM were significantly older than patients without TSM (median 14.3 years; range 10.1–18.1 vs. 12.4 years; range 0.1–18.9, p<0.001). TSM never appeared under sedation. Thirty of 50 scans in patients younger than 10 years were without sedation. TSM were not observed in non-sedated patients younger than 10 years of age (p = 0.028). In a logistic regression analysis, age remained the only cofactor independently associated with the occurrence of TSM (hazard ratio 9.152, p = 0.049). Conclusion TSM in Gd-EOB-DTPA-enhanced liver MRI do not appear in children under the age of 10 years.
Collapse
|
7
|
An unusual case of dysuria, pollakisuria, and eosinophilia: Answers. Pediatr Nephrol 2022; 37:793-795. [PMID: 34796394 PMCID: PMC8960575 DOI: 10.1007/s00467-021-05130-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/27/2021] [Accepted: 05/07/2021] [Indexed: 11/28/2022]
|
8
|
Anwendung von Kontrastmitteln in der Kinderradiologie. ROFO-FORTSCHR RONTG 2021; 193:S67-S68. [PMID: 34470071 DOI: 10.1055/a-1394-3635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
9
|
Characterization of the Hyperintense Bronchus Sign as a Fetal MRI Marker of Airway Obstruction. Radiology 2021; 300:423-430. [PMID: 34032511 DOI: 10.1148/radiol.2021204565] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Background Fetal MRI-based differential diagnosis of congenital lung malformations is difficult because of the paucity of well-described imaging markers. Purpose To characterize the hyperintense bronchus sign (HBS) in in vivo fetal MRI of congenital lung malformation cases. Materials and Methods In this retrospective two-center study, fetal MRI scans obtained in fetuses with congenital lung malformations at US (January 2002 to September 2018) were reviewed for the HBS, a tubular or branching hyperintense structure within a lung lesion on T2-weighted images. The frequency of the HBS and respective gestational ages in weeks and days were analyzed. Areas under the curve (AUCs), 95% CIs, and P values of the HBS regarding airway obstruction, as found in histopathologic and postnatal CT findings as the reference standards, were calculated for different gestational ages. Results A total of 177 fetuses with congenital lung malformations (95 male fetuses) and 248 fetal MRI scans obtained at a median gestational age of 25.6 weeks (interquartile range, 8.9 weeks) were included. The HBS was found in 79% (53 of 67) of fetuses with bronchial atresia, 71% (39 of 55) with bronchopulmonary sequestration (BPS), 43% (three of seven) with hybrid lesion, 15% (six of 40) with congenital cystic adenomatoid malformation, and 13% (one of eight) with bronchogenic cyst at a median gestational age of 24.9 weeks (interquartile range, 9.7 weeks). HBS on MRI scans at any gestational age had an AUC of 0.76 (95% CI: 0.70, 0.83; P = .04) for the presence of isolated or BPS-associated airway obstruction at histopathologic analysis and postnatal CT. The AUC of HBS on fetal MRI scans obtained until gestational age of 26 weeks (AUC, 0.83; 95% CI: 0.75, 0.91; P < .001) was significantly higher (P = .045) than that for fetal MRI scans obtained after gestational age 26 weeks (AUC, 0.69; 95% CI: 0.57, 0.80; P = .004). Conclusion The hyperintense bronchus sign is a frequently detectable feature at fetal MRI and is associated with airway obstruction particularly before gestational age 26 weeks. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Dubinsky in this issue.
Collapse
|
10
|
Circulating microRNAs 34a, 122, and 192 are linked to obesity-associated inflammation and metabolic disease in pediatric patients. Int J Obes (Lond) 2021; 45:1763-1772. [PMID: 33986456 PMCID: PMC8310785 DOI: 10.1038/s41366-021-00842-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 03/26/2021] [Accepted: 04/26/2021] [Indexed: 12/18/2022]
Abstract
BACKGROUND Obesity-associated chronic low-grade inflammation leads to dysregulation of central lipid and glucose metabolism pathways leading to metabolic disorders. MicroRNAs (miRNAs) are known to control regulators of metabolic homeostasis. We aimed to assess the relationship of circulating miRNAs with inflammatory modulators and metabolic disorders in pediatric obesity. METHODS From a pediatric cohort with severe obesity (n = 109), clinically thoroughly characterized including diverse routine blood parameters, oral glucose tolerance test, and liver MRI, a panel of 16 circulating miRNAs was quantified using qRT-PCR. Additionally, markers of inflammation TNFα, IL1 receptor antagonist, procalcitonin, CRP, and IL-6 were measured. RESULTS Markers of obesity-associated inflammation, TNFα, IL-1Ra, and procalcitonin, all significantly correlated with concentrations of miRNAs 122 and 192. Concentrations of these miRNAs negatively correlated with serum adiponectin and were among those strongly linked to parameters of dyslipidemia and liver function. Moreover, miRNA122 concentrations correlated with HOMA-IR. Several miRNA levels including miRNAs 34a, 93, 122, and 192 were statistically significantly differing between individuals with prediabetes, impaired glucose tolerance, metabolic syndrome, or nonalcoholic fatty liver disease compared to the respective controls. Additionally, miRNA 192 was significantly elevated in metabolically unhealthy obesity. CONCLUSIONS A miRNA pattern associated with obesity-associated inflammation and comorbidities may be used to distinguish metabolically healthy from unhealthy pediatric patients with obesity. Moreover, these changes in epigenetic regulation could potentially be involved in the etiology of obesity-linked metabolic disease in children and adolescents.
Collapse
|
11
|
A branched-chain amino acid-based metabolic score can predict liver fat in children and adolescents with severe obesity. Pediatr Obes 2021; 16:e12739. [PMID: 33058486 PMCID: PMC7988615 DOI: 10.1111/ijpo.12739] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Accepted: 09/28/2020] [Indexed: 12/18/2022]
Abstract
BACKGROUND Eighty percent of adolescents with severe obesity suffer from non-alcoholic fatty liver disease (NAFLD). Non-invasive prediction models have been tested in adults, however, they performed poorly in paediatric populations. OBJECTIVE This study aimed to investigate novel biomarkers for NAFLD and to develop a score that predicts liver fat in youth with severe obesity. METHODS From a population with a BMI >97th percentile aged 9-19 years (n = 68), clinically thoroughly characterized including MRI-derived proton density fat fraction (MRI-PDFF), amino acids and acylcarnitines were measured by HPLC-MS. RESULTS In children with NAFLD, higher levels of plasma branched-chain amino acids (BCAA) were determined. BCAAs correlated with MRI-PDFF (R = 0.46, p < .01). We identified a linear regression model adjusted for age, sex and pubertal stage consisting of BCAAs, ALT, GGT, ferritin and insulin that predicted MRI-PDFF (R = 0.75, p < .01). ROC analysis of this model revealed AUCs of 0.85, 0.85 and 0.92 for the detection of any, moderate and severe steatosis, respectively, thus markedly outperforming previously published scores. CONCLUSION BCAAs could be an important link between obesity and other metabolic pathways. A BCAA-based metabolic score can predict steatosis grade in high-risk children and adolescents and may provide a feasible alternative to sophisticated methods like MRI or biopsy in the future.
Collapse
|
12
|
Subsequent MRI of pediatric patients after an adverse reaction to Gadolinium-based contrast agents. PLoS One 2020; 15:e0230781. [PMID: 32243440 PMCID: PMC7122741 DOI: 10.1371/journal.pone.0230781] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2019] [Accepted: 03/09/2020] [Indexed: 11/19/2022] Open
Abstract
Background Gadolinium-based contrast agent (GBCA)-enhanced magnetic resonance imaging (MRI) scans often must be used repeatedly in pediatric oncologic patients. Although GBCAs are usually well tolerated, severe and life-threatening allergic reactions might occur, which can result in overly cautions adherence to special precautions in patients. Purpose To evaluate the management of the reported GBCA-associated adverse reactions in subsequent contrast-enhanced MRIs in pediatric patients, distinguishing non-allergic and allergic reactions. Materials and methods In this retrospective, cross-sectional study, consecutive pediatric neurooncological patients who underwent GBCA-enhanced MRI at our university hospital, between 2007 and 2016, were eligible. The patients’ history was evaluated with regard to any adverse events after GBCA administration. In a subset of patients with reported adverse reactions, the institutional premedication regime or an allergy work-up in clinical practice were performed, using either skin-prick tests or intravenous provocation tests in a double-blind procedure. Results Included were 8156 contrast-enhanced MRI scans in 2109 patients. Nineteen acute adverse events (19/8156; 0.23%) in 17 patients (17/2109; 0.81%) were reported. Despite a premedication regime in 14 patients, three patients (3/14; 21.4%) reported a breakthrough reaction. None of the 12 patients who underwent skin-prick tests or intravenous provocation tests showed allergic reactions. At least one well-tolerated GBCA was identified in almost every tested patient. Conclusion A fast-track allergy work-up can help to distinguish non-allergic and allergic reactions and to identify a well-tolerated GBCA, thus avoiding unnecessary premedication for subsequent GBCA administrations.
Collapse
|
13
|
An anthropomorphic phantom representing a prematurely born neonate for digital x-ray imaging using 3D printing: Proof of concept and comparison of image quality from different systems. Sci Rep 2019; 9:14357. [PMID: 31591433 PMCID: PMC6779877 DOI: 10.1038/s41598-019-50925-3] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Accepted: 09/19/2019] [Indexed: 02/06/2023] Open
Abstract
An anthropomorphic phantom for image optimization in neonatal radiography was developed, and its usability in optimizing image acquisition and processing demonstrated. The phantom was designed to mimic a patient image of a prematurely born neonate. A clinical x-ray (neonate <1 kg) taken with an effective dose of 11 µSv on a needle-crystal storage phosphor system was retrospectively selected from anonymized images as an appropriate template representing a standard case in neonatology imaging. The low dose level used in clinical imaging results in high image noise content. Therefore, the image had to be processed using structure preserving noise reduction. Pixel values were related to printing material thickness to result in a similar attenuation pattern as the original patient including support mattress. A 3D model generating a similar x-ray attenuation pattern on an image detector as a patient was derived accounting for beam hardening and perspective, and printed using different printing technologies. Best printing quality was achieved using a laser stereolithography printer. Phantom images from different digital radiography systems used in neonatal imaging were compared. Effects of technology, image processing, and radiation dose on diagnostic image quality can be assessed for otherwise identical anthropomorphic neonatal images not possible with patient images, facilitating optimization and standardization of imaging parameters and image appearance.
Collapse
|
14
|
Microvessel ultrasound of neonatal brain parenchyma: feasibility, reproducibility, and normal imaging features by superb microvascular imaging (SMI). Eur Radiol 2018; 29:2127-2136. [PMID: 30315420 PMCID: PMC6420458 DOI: 10.1007/s00330-018-5743-1] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2018] [Revised: 07/13/2018] [Accepted: 09/07/2018] [Indexed: 01/01/2023]
Abstract
Objectives To evaluate the feasibility and reproducibility of superb microvascular imaging (SMI) of the neonatal brain and to describe normal imaging features. Methods We performed transcranial ultrasound with SMI in 19 healthy term-born neonates. SMI was done according to a structured examination protocol, using two linear 18 MHz and 14 MHz transducers. Superficial and deep scans were acquired in the coronal and sagittal planes, using the left and right superior frontal gyri as anatomical landmarks. All SMI views were imaged by monochrome and colour SMI and evaluated with respect to visibility of extrastriatal (i.e. cortical and medullary) and striatal microvessels. Results We have described normal morphologic features of intraparenchymal brain microvasculature as “short parallel” cortical vessels, “smoothly curved” medullary vessels, and deep striatal vessels. In general, SMI performance was better on coronal views than on sagittal views. On superficial coronal scans, cortical microvessels were identifiable in 90–100%, medullary microvessels in 95–100%. On deep scans, cortical and medullary microvessels were visible in all cases, while striatal microvessels were identifiable in 71% of cases. Conclusions Cerebral SMI ultrasound is feasible and well-reproducible and provides a novel non-invasive imaging tool for the assessment of intraparenchymal brain microvasculature (extrastriatal and striatal microvessels) in neonates without the use of contrast. Key Points • Superb microvascular imaging (SMI) of the neonatal brain is feasible and reproducible. • SMI depicts extrastriatal and striatal microvessels. • SMI detects two types of extrastriatal microvessels: cortical and medullary. Electronic supplementary material The online version of this article (10.1007/s00330-018-5743-1) contains supplementary material, which is available to authorized users.
Collapse
|
15
|
Automated tube voltage selection in pediatric non-contrast chest CT. PLoS One 2018; 13:e0204794. [PMID: 30281614 PMCID: PMC6169939 DOI: 10.1371/journal.pone.0204794] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2018] [Accepted: 09/15/2018] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Modern CT scanners provide automatic dose adjustment systems, which are promising options for reducing radiation dose in pediatric CT scans. Their impact on patient dose, however, has not been investigated sufficiently thus far. OBJECTIVE To evaluate automated tube voltage selection (ATVS) in combination with automated tube current modulation (ATCM) in non-contrast pediatric chest CT, with regard to the diagnostic image quality. MATERIALS AND METHODS There were 160 non-contrast pediatric chest CT scans (8.7±5.4 years) analyzed retrospectively without and with ATVS. Correlations of volume CT Dose Index (CTDIvol) and effective diameter, with and without ATVS, were compared using Fisher's z-transformation. Image quality was assessed by mean signal-difference-to-noise ratios (SDNR) in the aorta and in the left main bronchus using the independent samples t-test. Two pediatric radiologists and a general radiologist rated overall subjective Image quality. Readers' agreement was assessed using weighted kappa coefficients. A p value <0.05 was considered significant. RESULTS CTDIvol correlation with the effective diameter was r = 0.62 without and r = 0.80 with ATVS (CI: -0.04 to -0.60; p = 0.025). Mean SDNR was 10.88 without and 10.03 with ATVS (p = 0.0089). Readers' agreement improved with ATVS (weighted kappa between pediatric radiologists from 0.1 (0.03-0.16) to 0.27 (0.09-0.45) with ATVS; between general and each pediatric radiologist from 0.1 (0.06-0.14) to 0.12 (0.05-0.20), and from 0.22 (0.11-0.34) to 0.36 (0.24-0.49)). CONCLUSION ATVS, combined with ATCM, results in a radiation dose reduction for pediatric non-contrast chest CT without a loss of diagnostic image quality and prevents errors in manual tube voltage setting, and thus protecting larger children against an unnecessarily high radiation exposure.
Collapse
|
16
|
Monitoring of plexiform neurofibroma in children and adolescents with neurofibromatosis type 1 by [ 18 F]FDG-PET imaging. Is it of value in asymptomatic patients? Pediatr Blood Cancer 2018; 65. [PMID: 28771999 DOI: 10.1002/pbc.26733] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2017] [Revised: 06/20/2017] [Accepted: 07/02/2017] [Indexed: 12/27/2022]
Abstract
PURPOSE About 10% of patients with neurofibromatosis type 1 (NF-1) develop malignant peripheral nerve sheath tumours (MPNST) mostly arising in plexiform neurofibroma (PN); 15% of MPNST arise in children and adolescents. 2-[18 F]fluoro-2-deoxy-d-glucose ([18 F]FDG)-PET (where PET is positron emission tomography) is a sensitive method in differentiating PN and MPNST in symptomatic patients with NF-1. This study assesses the value of [18 F]FDG-PET imaging in detecting malignant transformation in symptomatic and asymptomatic children with PN. METHODS Forty-one patients with NF-1 and extensive PN underwent prospective [18 F]FDG imaging from 2003 to 2014. Thirty-two of the patients were asymptomatic. PET data, together with histological results and clinical course were re-evaluated retrospectively. Maximum standardised uptake values (SUVmax) and lesion-to-liver ratio were assessed. RESULTS A total of 104 examinations were performed. Mean age at first PET was 13.5 years (2.6-22.6). Eight patients had at least one malignant lesion; four of these patients were asymptomatic. Two of four symptomatic patients died, while all patients with asymptomatic malignant lesions are alive. All malignant tumours could be identified by PET imaging in both symptomatic and asymptomatic patients. All lesions judged as benign by [18 F]FDG imaging and clinical judgment were either histologically benign if removed or remained clinically silent during follow-up. SUVmax of malignant and benign lesions overlapped, but no malignant lesion showed FDG uptake ≤3.15. Asymptomatic malignant lesions were detected with a sensitivity of 100%, a negative predictive value of 100% and a specificity of 45.1%. CONCLUSION Malignant transformation of PN also occurs in asymptomatic children and adolescents. Detection of MPNST at early stages could increase the possibility of oncologically curative resections.
Collapse
|
17
|
Hand MRI and the Greulich-Pyle atlas in skeletal age estimation in adolescents. Skeletal Radiol 2018; 47:963-971. [PMID: 29372277 PMCID: PMC5960481 DOI: 10.1007/s00256-017-2867-3] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/15/2017] [Revised: 12/09/2017] [Accepted: 12/27/2017] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To evaluate the feasibility of hand MRI in age assessment in adolescents using the Greulich-Pyle (GP) atlas criteria. MATERIALS AND METHODS Two radiologists, who were blinded to the study subjects' chronologic ages, semi-objectively evaluated 1.5-T MRIs of the left hands of ten patients (13.5 ± 2.6 years) who had left-hand radiographs and 50 healthy volunteers (15 ± 2 years). RESULTS A coronal T1-weighted, volumetric, interpolated, breath-hold examination with water excitation (T1 VIBE-3D-WE) achieved the best image quality. The correlation between estimated patients' ages on radiographs and MRI was high. The average estimated age difference between the MRIs and radiographs was -0.05 years for reader 1 and -0.175 years for reader 2. The interclass coefficients (ICCs) showed high interobserver agreement (radiographs: ICC = 0.95, MRI: ICC = 0.97). The ICC, calculated separately for the male and female volunteers' estimated ages by MRI, also showed a high agreement between the two readers (male: ICC = 0.97, female: ICC = 0.95). Reader 1 estimated 94% of volunteers within 2 standard deviations (SD) and 62% within 1 SD. The results for reader 2 were 92% and 54%, respectively. Thirty-nine percent of girls and 27% of boys were estimated to be older using 1 SD. CONCLUSION MRI of the left hand is a feasible alternative to hand radiographs for skeletal age estimation in adolescents using the GP criteria with 2 SD. Using 1 SD, the age of healthy volunteers tended to be estimated as higher than the chronologic age. Future studies should evaluate the results in a larger number of participants.
Collapse
|
18
|
Acute Respiratory Distress in a Child with H3N2 Infection. KLINISCHE PADIATRIE 2017; 230:50-52. [PMID: 28895618 DOI: 10.1055/s-0043-117961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
19
|
Design of a head phantom produced on a 3D rapid prototyping printer and comparison with a RANDO and 3M lucite head phantom in eye dosimetry applications. Phys Med Biol 2017; 62:3158-3174. [PMID: 28192281 DOI: 10.1088/1361-6560/aa602c] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
An anthropomorphic head phantom including eye inserts allowing placement of TLDs 3 mm below the cornea has been produced on a 3D printer using a photo-cured acrylic resin to best allow tissue equivalence. Thus Hp(3) can be determined in radiological and interventional photon radiation fields. Eye doses and doses to the forehead have been compared to an Alderson RANDO head and a 3M Lucite skull phantom in terms of surface dose per incident air kerma for frontal irradiation since the commercial phantoms do not allow placement of TLDs 3 mm below the corneal surface. A comparison of dose reduction factors (DRFs) of a common lead glasses model has also been performed. Eye dose per incident air kerma were comparable between all three phantoms (printed phantom: 1.40, standard error (SE) 0.04; RANDO: 1.36, SE 0.03; 3M: 1.37, SE 0.03). Doses to the forehead were identical to eye surface doses for the printed phantom and the RANDO head (ratio 1.00 SE 0.04, and 0.99 SE 0.03, respectively). In the 3M Lucite skull phantom dose on the forehead was 15% lower than dose to the eyes attributable to phantom properties. DRF of a sport frame style leaded glasses model with 0.75 mm lead equivalence measured were 6.8 SE 0.5, 9.3 SE 0.4 and 10.5 SE 0.5 for the RANDO head, the printed phantom, and the 3M Lucite head phantom, respectively, for frontal irradiation. A comparison of doses measured in 3 mm depth and on the surface of the eyes in the printed phantom revealed no difference larger than standard errors from TLD dosimetry. 3D printing offers an interesting opportunity for phantom design with increasing potential as printers allowing combinations of tissue substitutes will become available. Variations between phantoms may provide a useful indication of uncertainty budgets when using phantom measurements to estimate individual personnel doses.
Collapse
|
20
|
[Minimal-invasive Cholecystocolostomy as Surgical Bridging Procedure in Patients with Progressive Familial Intrahepatic Cholestasis (PFIC)]. KLINISCHE PADIATRIE 2016; 228:91-3. [PMID: 27023124 DOI: 10.1055/s-0041-111176] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
21
|
|
22
|
NGTS-0118F-FDG PET AND PET / CT MONITORING OF PLEXIFORM NEUROFIBROMA IN CHILDREN AND ADOLESCENTS WITH NEUROFIBROMATOSIS TYPE 1. Neuro Oncol 2015. [DOI: 10.1093/neuonc/nov224.01] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
23
|
[Protection of the unborn child in diagnostic and interventional radiological procedures]. Radiologe 2015. [PMID: 26220128 DOI: 10.1007/s00117-015-2816-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
The radiation exposure of an unborn child should be principally avoided, whenever it is medically reasonably possible; therefore, the identification of pregnant patients is the first and the most important step in radiation protection of the unborn child. However, in cases of emergency saving the life of the patient has a higher priority than the radiation protection of the unborn child. In this review article, we present a longitudinal section through the national and international literature and guidelines as a basis for radiological management of a (possibly) pregnant patient. We also list some radiological procedures recommended in the literature for a series of maternal indications considering the contraindications of each method during pregnancy and radiation protection of the unborn child.
Collapse
|
24
|
Effect of staff training on radiation dose in pediatric CT. Eur J Radiol 2015; 84:1574-1578. [PMID: 26001436 DOI: 10.1016/j.ejrad.2015.04.027] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2014] [Revised: 03/22/2015] [Accepted: 04/23/2015] [Indexed: 12/30/2022]
Abstract
OBJECTIVE To evaluate the efficacy of staff training on radiation doses applied in pediatric CT scans. METHODS Pediatric patient doses from five CT scanners before (1426 scans) and after staff training (2566 scans) were compared statistically. Examinations included cranial CT (CCT), thoracic, abdomen-pelvis, and trunk scans. Dose length products (DLPs) per series were extracted from CT dose reports archived in the PACS. RESULTS A pooled analysis of non-traumatic scans revealed a statistically significant reduction in the dose for cranial, thoracic, and abdomen/pelvis scans (p<0.01). This trend could be demonstrated also for trunk scans, however, significance could not be established due to low patient frequencies (p>0.05). The percentage of scans performed with DLPs exceeding the German DRLs was reduced from 41% to 7% (CCT), 19% to 5% (thorax-CT), from 9% to zero (abdominal-pelvis CT), and 26% to zero (trunk; DRL taken as summed DRLs for thorax plus abdomen-pelvis, reduced by 20% accounting for overlap). Comparison with Austrian DRLs - available only for CCT and thorax CT - showed a reduction from 21% to 3% (CCT), and 15 to 2% (thorax CT). CONCLUSIONS Staff training together with application of DRLs provide an efficient approach for optimizing radiation dose in pediatric CT practice.
Collapse
|
25
|
Epididymal Reflux in Posterior Urethral Valves. Urology 2011; 78:60. [DOI: 10.1016/j.urology.2010.04.043] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2010] [Revised: 04/18/2010] [Accepted: 04/26/2010] [Indexed: 10/19/2022]
|
26
|
Hojreh A. . Eur J Radiol 2011; 78:e2. [DOI: 10.1016/j.ejrad.2011.01.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
27
|
Book review. Eur J Radiol 2009. [DOI: 10.1016/j.ejrad.2009.03.040] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
28
|
Abstract
This review focuses on the occurrence, imaging and differential diagnosis of insufficiency fractures. Prevalence, the most common sites of insufficiency fractures and their clinical implications are discussed. Insufficiency fractures occur with normal stress exerted on weakened bone. Postmenopausal osteoporosis is the most common cause of insufficiency fractures. Other conditions which affect bone turnover include osteomalacia, hyperparathyroidism, chronic renal failure and high-dose glucocorticoid therapy. It is a challenge for the radiologist to detect and diagnose insufficiency fractures, and to differentiate them from other bone lesions. Radiographs are still the most widely used imaging method for identification of insufficiency fractures, but sensitivity is limited, depending on the location of the fractures. Magnetic resonance imaging (MRI) is a very sensitive tool to visualize bone marrow abnormalities associated with insufficiency fractures. Thin section, multi-detector computed tomography (MDCT) depicts subtle fracture lines allowing direct visualization of cortical and trabecular bone. Bone scintigraphy still plays a role in detecting fractures, with good sensitivity but limited specificity. The most important differential diagnosis is underlying malignant disease leading to pathologic fractures. Bone densitometry and clinical history may also be helpful in confirming the diagnosis of insufficiency fractures.
Collapse
|
29
|
Book review. Eur J Radiol 2009. [DOI: 10.1016/j.ejrad.2008.07.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
30
|
Hojreh A. Eur J Radiol 2009; 69:360. [DOI: 10.1016/j.ejrad.2007.10.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
31
|
Vergleich unterschiedlicher Rekonstruktionsalgorithmen von Multi-Detektor-CT-Untersuchungen bei Extremitätenfrakturen. ROFO-FORTSCHR RONTG 2008. [DOI: 10.1055/s-2008-1073699] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
32
|
Dose classification scheme for computed tomography of the paranasal sinuses. Eur J Radiol 2006; 56:31-7. [PMID: 16168261 DOI: 10.1016/j.ejrad.2004.12.006] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2004] [Revised: 12/15/2004] [Accepted: 12/20/2004] [Indexed: 11/18/2022]
Abstract
PURPOSE The purpose of this study was to define objective and reproducible standards for the quality of CT images as a function of radiation doses and therapeutic validity. MATERIALS AND METHODS CT images of the paranasal sinuses of 145 patients (77 female, 68 male; 5-83 years old; mean age, 39.9 years) were classified both subjectively (with a view toward their validity for the planning of functional endoscopic sinus surgery, FESS) and objectively by defining the pixel noise (the standard deviation, STD, of the CT number) in a homogeneous region of interest (ROI), centered on the M. masseter and on the frontal lobe. These measurements were then compared to measurements obtained from scan images of a water-filled Perspex phantom. RESULTS The pixel noise measured in the phantom images was nearly identical to the respective values on the M. masseter on the patient images. The use of an edge-enhancing reconstruction algorithm and low-dose protocols, with a pixel noise amounting to 70-90 Hounsfield Units (HU), are indicated for children, chronic sinusitis, and septum deviation, while standard protocols, with a pixel noise of 50-70 HU, are recommended for the preoperative planning and postoperative control of FESS. The pixel noise for high-dose protocols is less than 50 HU; nonetheless, such protocols should generally be avoided. CONCLUSION The pixel noise measured in a water-filled Perspex phantom is indicative of the clinical potential and image quality of paranasal sinus CT scans. Alternatively, the M. masseter can be chosen as an ROI to measure the pixel noise in order to obtain a rough estimate of the image quality or radiation dose class.
Collapse
|
33
|
Hojreh A. Eur J Radiol 2006; 57:162. [DOI: 10.1016/j.ejrad.2005.06.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
34
|
Abstract
In the past years, multislice CT (MS-CT) has become an important diagnostic modality for the radiological evaluation of the thorax in children and adolescents. However, the higher stochastic radiation risks in pediatric patients, as compared to adults, necessitate a prudent use of MS-CT. This article presents an overview of the benefits of multislice CT and a variety of possibilities for radiation reduction in pediatric patients of different ages.
Collapse
|
35
|
Abstract
Recent studies in the USA and Europe state that computed tomography (CT) scans compromise only 3-5% of all radiological exams, but they contribute 35-45% of total radiation dose to the patient population. These studies lead to concern by several public authorities. Basis of CT-dose measurements is the computed tomography dose index (CTDI), which was established 1981. Nowadays there are several modifications of the CTDI values, which may lead to confusion. It is suggested to use the standardized CTDI-100 w. value together with the dose length product in all CT-examinations. These values should be printed on all CT-images and allows an evaluation of the individualized patient dose. Nowadays, radiologist's aim must be to work at the lowest maximal diagnostic acceptable signal to noise ratio. To decrease radiation dose radiologist should use low kV and mA, but high pitches. Newly developed CT-dose-reduction soft-wares and filters should be installed in all CT-machines. We should critically compare the average dose used for a specific examination with the reference dose used in this country and/or Europe. Greater differences should caution the radiologist. Finally, we as radiologists must check very carefully all indications and recommend alternative imaging methods. But we have also to teach our customers-patients and medical doctors who are non-radiologists-that a 'good' image is not that which show all possible information, but that which visualize 'only' the diagnostic necessary information.
Collapse
|
36
|
[Dose classification in digital roentgen diagnosis: clinical applications]. WIENER MEDIZINISCHE WOCHENSCHRIFT. SUPPLEMENT 2003:48-50. [PMID: 12621841] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 03/01/2023]
Abstract
Technological improvements in digital radiography and computed tomography have led to a substantial increase of radiation dose that subjectively cannot be detected. In order to reduce dose in a form that may be used in clinical practise, the quality of digital radiograms and computed tomography images should be classified in three classes. Low-dose investigations are indicated in children, in case of therapy control and for imaging organs with high differences in tissue contrast. High-dose investigations are scarcely indicated and middle-dose investigations should be performed in all other remaining clinical situations. Dose recommendations given by vendors in radiology should be viewed critically.
Collapse
|