1
|
Regnery J, Rohner S, Bachtin J, Möhlenkamp C, Zinke O, Jacob S, Wohlsein P, Siebert U, Reifferscheid G, Friesen A. First evidence of widespread anticoagulant rodenticide exposure of the Eurasian otter (Lutra lutra) in Germany. Sci Total Environ 2024; 907:167938. [PMID: 37866608 DOI: 10.1016/j.scitotenv.2023.167938] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2023] [Revised: 10/13/2023] [Accepted: 10/17/2023] [Indexed: 10/24/2023]
Abstract
Exposure of wildlife to anticoagulant rodenticides (ARs) has been extensively documented for species directly or indirectly linked to pest rodents via the terrestrial food web. Recently, the scientific focus extended to a former blind spot, namely AR emissions to the aquatic environment, and provided clear evidence of AR residues in freshwater fish. As second-generation ARs are likely to be transferred along the aquatic food chain, a total of 122 Eurasian otter (Lutra lutra) individuals found dead in Germany between 2005 and 2021 were investigated to shed more light on resultant environmental risks. Target analytes comprised one pharmaceutical and eight biocidal anticoagulants, as well as one suspected bait impurity. Notably, all target compounds were detected in the analyzed livers of otters, a primarily piscivorous top predator and indicator species for the aquatic environment, strictly protected by conservation laws. In regions with pronounced rodent control measures, otters were frequently exposed to biocidal ARs. The elevated AR levels measured in multiple otters, compared to freshwater fish, hinted at biomagnification of second-generation ARs within the aquatic food web. The results indicated that risk mitigation measures implemented in Germany within the biocidal product authorization may not be sufficient to protect aquatic non-target wildlife from AR exposure, challenging the effectiveness of current regulatory measures.
Collapse
Affiliation(s)
- Julia Regnery
- Federal Institute of Hydrology, Department of Biochemistry and Ecotoxicology, 56068 Koblenz, Germany.
| | - Simon Rohner
- University of Veterinary Medicine Hannover, Foundation, Institute for Terrestrial and Aquatic Wildlife Research, 25761 Büsum, Germany
| | - Julia Bachtin
- Federal Institute of Hydrology, Department of Biochemistry and Ecotoxicology, 56068 Koblenz, Germany
| | - Christel Möhlenkamp
- Federal Institute of Hydrology, Department of Biochemistry and Ecotoxicology, 56068 Koblenz, Germany
| | - Olaf Zinke
- Museum of the Westlausitz Kamenz, Department of Zoology, 01917 Kamenz, Germany
| | - Stefanie Jacob
- German Environment Agency, Section IV 1.2 Biocides, 06844 Dessau-Rosslau, Germany
| | - Peter Wohlsein
- University of Veterinary Medicine Hannover, Foundation, Department of Pathology, 30559 Hannover, Germany
| | - Ursula Siebert
- University of Veterinary Medicine Hannover, Foundation, Institute for Terrestrial and Aquatic Wildlife Research, 25761 Büsum, Germany
| | - Georg Reifferscheid
- Federal Institute of Hydrology, Department of Biochemistry and Ecotoxicology, 56068 Koblenz, Germany
| | - Anton Friesen
- German Environment Agency, Section IV 1.2 Biocides, 06844 Dessau-Rosslau, Germany
| |
Collapse
|
2
|
Becker B, Kochleus C, Spira D, Möhlenkamp C, Bachtin J, Meinecke S, Vermeirssen ELM. Passive sampler phases for pesticides: evaluation of AttractSPE™ SDB-RPS and HLB versus Empore™ SDB-RPS. Environ Sci Pollut Res Int 2021; 28:11697-11707. [PMID: 33438128 PMCID: PMC7886826 DOI: 10.1007/s11356-020-12109-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Accepted: 12/14/2020] [Indexed: 05/04/2023]
Abstract
In this study, three different passive sampling receiving phases were evaluated, with a main focus on the comparability of established styrene-divinylbenzene reversed phase sulfonated (SDB-RPS) sampling phase from Empore™ (E-RPS) and novel AttractSPE™ (A-RPS). Furthermore, AttractSPE™ hydrophilic-lipophilic balance (HLB) disks were tested. To support sampling phase selection for ongoing monitoring needs, it is important to have information on the characteristics of alternative phases. Three sets of passive samplers (days 1-7, days 8-14, and days 1-14) were exposed to a continuously exchanged mixture of creek and rainwater in a stream channel system under controlled conditions. The system was spiked with nine pesticides in two peak scenarios, with log KOW values ranging from approx. - 1 to 5. Three analytes were continuously spiked at a low concentration. All three sampling phases turned out to be suitable for the chosen analytes, and, in general, uptake rates were similar for all three materials, particularly for SDB-RPS phases. Exceptions concerned bentazon, where E-RPS sampled less than 20% compared with the other phases, and nicosulfuron, where HLB sampled noticeably more than both SDB-RPS phases. All three phases will work for environmental monitoring. They are very similar, but differences indicate one cannot just use literature calibration data and transfer these from one SDB phase to another, though for most compounds, it may work fine.
Collapse
Affiliation(s)
- Benjamin Becker
- German Federal Institute of Hydrology (BfG), Am Mainzer Tor 1, 56068 Koblenz, Germany
| | - Christian Kochleus
- German Federal Institute of Hydrology (BfG), Am Mainzer Tor 1, 56068 Koblenz, Germany
| | - Denise Spira
- German Federal Institute of Hydrology (BfG), Am Mainzer Tor 1, 56068 Koblenz, Germany
| | - Christel Möhlenkamp
- German Federal Institute of Hydrology (BfG), Am Mainzer Tor 1, 56068 Koblenz, Germany
| | - Julia Bachtin
- German Federal Institute of Hydrology (BfG), Am Mainzer Tor 1, 56068 Koblenz, Germany
| | - Stefan Meinecke
- German Environment Agency (UBA), Schichauweg 58, 12307 Berlin, Germany
| | | |
Collapse
|
3
|
Regnery J, Parrhysius P, Schulz RS, Möhlenkamp C, Buchmeier G, Reifferscheid G, Brinke M. Wastewater-borne exposure of limnic fish to anticoagulant rodenticides. Water Res 2019; 167:115090. [PMID: 31553930 DOI: 10.1016/j.watres.2019.115090] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2019] [Revised: 09/12/2019] [Accepted: 09/13/2019] [Indexed: 05/15/2023]
Abstract
The recent emergence of second-generation anticoagulant rodenticides (AR) in the aquatic environment emphasizes the relevance and impact of aquatic exposure pathways during rodent control. Pest control in municipal sewer systems of urban and suburban areas is thought to be an important emission pathway for AR to reach wastewater and municipal wastewater treatment plants (WWTP), respectively. To circumstantiate that AR will enter streams via effluent discharges and bioaccumulate in aquatic organisms despite very low predicted environmental emissions, we conducted a retrospective biological monitoring of fish tissue samples from different WWTP fish monitoring ponds exclusively fed by municipal effluents in Bavaria, Germany. At the same time, information about rodent control in associated sewer systems was collected by telephone survey to assess relationships between sewer baiting and rodenticide residues in fish. In addition, mussel and fish tissue samples from several Bavarian surface waters with different effluent impact were analyzed to evaluate the prevalence of anticoagulants in indigenous aquatic organisms. Hepatic AR residues were detected at 12 out of 25 WWTP sampling sites in the low μg/kg range, thereof six sites with one or more second-generation AR (i.e., brodifacoum, difenacoum, bromadiolone). 14 of 18 surveyed sites confirmed sewer baiting with AR and detected hepatic residues matched the reported active ingredients used for sewer baiting at six sites. Furthermore, second-generation AR were detected in more than 80% of fish liver samples from investigated Bavarian streams. Highest total hepatic AR concentrations in these fish were 9.1 and 8.5 μg/kg wet weight, respectively and were observed at two riverine sampling sites characterized by close proximity to upstream WWTP outfalls. No anticoagulant residues were found in fish liver samples from two lakes without known influences of effluent discharges. The findings of our study clearly show incomplete removal of anticoagulants during conventional wastewater treatment and confirm exposure of aquatic organisms via municipal effluents. Based on the demonstrated temporal and spatial coherence between sewer baiting and hepatic AR residues in effluent-exposed fish, sewer baiting in combined sewer systems contributes to the release of active ingredients into the aquatic environment.
Collapse
Affiliation(s)
- Julia Regnery
- Department of Biochemistry, Ecotoxicology, Federal Institute of Hydrology, Am Mainzer Tor 1, 56068 Koblenz, Germany.
| | - Pia Parrhysius
- Department of Biochemistry, Ecotoxicology, Federal Institute of Hydrology, Am Mainzer Tor 1, 56068 Koblenz, Germany
| | - Robert S Schulz
- Department of Biochemistry, Ecotoxicology, Federal Institute of Hydrology, Am Mainzer Tor 1, 56068 Koblenz, Germany
| | - Christel Möhlenkamp
- Department of Biochemistry, Ecotoxicology, Federal Institute of Hydrology, Am Mainzer Tor 1, 56068 Koblenz, Germany
| | - Georgia Buchmeier
- Unit Aquatic Ecotoxicology, Microbial Ecology, Bavarian Environment Agency, Demollstr. 31, 82407 Wielenbach, Germany
| | - Georg Reifferscheid
- Department of Biochemistry, Ecotoxicology, Federal Institute of Hydrology, Am Mainzer Tor 1, 56068 Koblenz, Germany
| | - Marvin Brinke
- Department of Biochemistry, Ecotoxicology, Federal Institute of Hydrology, Am Mainzer Tor 1, 56068 Koblenz, Germany
| |
Collapse
|
4
|
Niehus NC, Schäfer S, Möhlenkamp C, Witt G. Equilibrium sampling of HOCs in sediments and suspended particulate matter of the Elbe River. Environ Sci Eur 2018; 30:28. [PMID: 30148025 PMCID: PMC6097018 DOI: 10.1186/s12302-018-0159-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/21/2018] [Accepted: 07/23/2018] [Indexed: 06/08/2023]
Abstract
BACKGROUND Chemical quality of sediment and suspended particulate matter (SPM) is usually assessed by total chemical concentrations (Ctotal). However, the freely dissolved concentration (Cfree) is the ecologically more relevant parameter for bioavailability, diffusion and bioaccumulation. In recent studies, equilibrium sampling has been applied to determine Cfree of hydrophobic organic contaminants (HOCs) in the sediment pore water, whereas such data are missing for SPM. We applied solid-phase micro-extraction to measure and compare Cfree of PAHs and PCBs in pore water of sediments and SPM sampled along the German part of the river Elbe. Moreover, site-specific distribution ratios were evaluated and Cbio,lipid was predicted using Cfree. RESULTS Cfree of PAHs remained largely constant while Cfree of PCBs varied along the Elbe River. The highest Ctotal of PCBs and PAHs were found at Prossen (km 13) and Meißen (km 96). PCB Ctotal even exceeded the environmental quality standard for sediment and SPM in Prossen. Site-specific distribution ratios (KD) revealed a stronger sorption for PAHs compared to PCBs, indicating a higher availability of PCBs. Equilibrium partitioning concentrations in lipids (Clip↔sed) showed a high correlation with actually measured lipid-normalised concentrations (Cbio,lipid) in bream. This indicates that PCB bioaccumulation in this benthic fish species is closely linked to the sediment contamination. CONCLUSIONS In rivers, SPM functions as a transportation vehicle for HOCs along the stream until it eventually deposits to the sediment. This study demonstrates that due to weaker sorption of PAHs and PCBs to the SPM this matrix poses a higher risk to the aquatic environment compared to the sediment. The prediction of Cbio,lipid of PCBs was correct and shows that solid-phase micro-extraction is highly suited to predict lipid concentration, and thus a valuable tool for risk-assessment or sediment management.
Collapse
Affiliation(s)
- Nora Claire Niehus
- Hamburg University of Applied Sciences, Ulmenliet 20, 21033 Hamburg, Germany
| | - Sabine Schäfer
- German Federal Institute of Hydrology, Am Mainzer Tor 1, 56068 Koblenz, Germany
| | - Christel Möhlenkamp
- German Federal Institute of Hydrology, Am Mainzer Tor 1, 56068 Koblenz, Germany
| | - Gesine Witt
- Hamburg University of Applied Sciences, Ulmenliet 20, 21033 Hamburg, Germany
| |
Collapse
|
5
|
Haegerbaeumer A, Höss S, Ristau K, Claus E, Möhlenkamp C, Heininger P, Traunspurger W. A comparative approach using ecotoxicological methods from single-species bioassays to model ecosystems. Environ Toxicol Chem 2016; 35:2987-2997. [PMID: 27155316 DOI: 10.1002/etc.3482] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2016] [Revised: 02/15/2016] [Accepted: 05/06/2016] [Indexed: 06/05/2023]
Abstract
Soft sediments are often hotspots of chemical contamination, and a thorough ecotoxicological assessment of this habitat can help to identify the causes of stress and to improve the health of the respective ecosystems. As an important component of the ecologically relevant meiobenthic fauna, nematodes can be used for sediment assessments, with various assay tools ranging from single-species toxicity tests to field studies. In the present study, microcosms containing sediment were used to investigate direct and indirect effects of zinc on natural nematode assemblages, and acute community toxicity tests considering only direct toxicity were conducted. The responses of the various freshwater nematode species in both approaches were compared with those of Caenorhabditis elegans, determined in standardized tests (ISO 10872). At a median lethal concentration (LC50) of 20 mg Zn/L, C. elegans represented the median susceptibility of 15 examined nematode species examined in the acute community toxicity tests. In the microcosms, Zn affected the nematodes dose-dependently, with changes in species composition first detected at 13 mg Zn/kg to 19 mg Zn/kg sediment dry weight. The observed species sensitivities in the microcosms corresponded better to field observations than to the results of the acute community toxicity tests. Environ Toxicol Chem 2016;35:2987-2997. © 2016 SETAC.
Collapse
Affiliation(s)
- Arne Haegerbaeumer
- Department of Animal Ecology, University of Bielefeld, Bielefeld, Germany
| | - Sebastian Höss
- Ecological Sediment and Soil Assessment, Starnberg, Germany
| | - Kai Ristau
- Department of Animal Ecology, University of Bielefeld, Bielefeld, Germany
| | - Evelyn Claus
- German Federal Institute of Hydrology, Koblenz, Germany
| | | | | | | |
Collapse
|
6
|
Fischer F, Böhm L, Höss S, Möhlenkamp C, Claus E, Düring RA, Schäfer S. Passive Dosing in Chronic Toxicity Tests with the Nematode Caenorhabditis elegans. Environ Sci Technol 2016; 50:9708-9716. [PMID: 27494096 DOI: 10.1021/acs.est.6b02956] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
In chronic toxicity tests with Caenorhabditis elegans, it is necessary to feed the nematode with bacteria, which reduces the freely dissolved concentration (Cfree) of hydrophobic organic chemicals (HOCs), leading to poorly defined exposure with conventional dosing procedures. We examined the efficacy of passive dosing of polycyclic aromatic hydrocarbons (PAHs) using silicone O-rings to control exposure during C. elegans toxicity testing and compared the results to those obtained with solvent spiking. Solid-phase microextraction and liquid-liquid extraction were used to measure Cfree and the chemicals taken up via ingestion. During toxicity testing, Cfree decreased by up to 89% after solvent spiking but remained constant with passive dosing. This led to a higher apparent toxicity on C. elegans exposed by passive dosing than by solvent spiking. With increasing bacterial cell densities, Cfree of solvent-spiked PAHs decreased while being maintained constant with passive dosing. This resulted in lower apparent toxicity under solvent spiking but an increased apparent toxicity with passive dosing, probably as a result of the higher chemical uptake rate via food (CUfood). Our results demonstrate the utility of passive dosing to control Cfree in routine chronic toxicity testing of HOCs. Moreover, both chemical uptake from water or via food ingestion can be controlled, thus enabling the discrimination of different uptake routes in chronic toxicity studies.
Collapse
Affiliation(s)
- Fabian Fischer
- German Federal Institute of Hydrology (BfG) , Am Mainzer Tor 1, 56068 Koblenz, Germany
- Institute of Soil Science and Soil Conservation, Research Center for BioSystems, Land Use, and Nutrition (iFZ), Justus Liebig University Giessen , Heinrich-Buff-Ring 26-32, 35392 Giessen, Germany
| | - Leonard Böhm
- Institute of Soil Science and Soil Conservation, Research Center for BioSystems, Land Use, and Nutrition (iFZ), Justus Liebig University Giessen , Heinrich-Buff-Ring 26-32, 35392 Giessen, Germany
| | | | - Christel Möhlenkamp
- German Federal Institute of Hydrology (BfG) , Am Mainzer Tor 1, 56068 Koblenz, Germany
| | - Evelyn Claus
- German Federal Institute of Hydrology (BfG) , Am Mainzer Tor 1, 56068 Koblenz, Germany
| | - Rolf-Alexander Düring
- Institute of Soil Science and Soil Conservation, Research Center for BioSystems, Land Use, and Nutrition (iFZ), Justus Liebig University Giessen , Heinrich-Buff-Ring 26-32, 35392 Giessen, Germany
| | - Sabine Schäfer
- German Federal Institute of Hydrology (BfG) , Am Mainzer Tor 1, 56068 Koblenz, Germany
| |
Collapse
|
7
|
Schäfer S, Antoni C, Möhlenkamp C, Claus E, Reifferscheid G, Heininger P, Mayer P. Equilibrium sampling of polychlorinated biphenyls in River Elbe sediments--Linking bioaccumulation in fish to sediment contamination. Chemosphere 2015; 138:856-862. [PMID: 26313858 DOI: 10.1016/j.chemosphere.2015.08.032] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2015] [Revised: 08/04/2015] [Accepted: 08/07/2015] [Indexed: 06/04/2023]
Abstract
Equilibrium sampling can be applied to measure freely dissolved concentrations (cfree) of hydrophobic organic chemicals (HOCs) that are considered effective concentrations for diffusive uptake and partitioning. It can also yield concentrations in lipids at thermodynamic equilibrium with the sediment (clip⇌sed) by multiplying concentrations in the equilibrium sampling polymer with lipid to polymer partition coefficients. We have applied silicone coated glass jars for equilibrium sampling of seven 'indicator' polychlorinated biphenyls (PCBs) in sediment samples from ten locations along the River Elbe to measure cfree of PCBs and their clip⇌sed. For three sites, we then related clip⇌sed to lipid-normalized PCB concentrations (cbio,lip) that were determined independently by the German Environmental Specimen Bank in common bream, a fish species living in close contact with the sediment: (1) In all cases, cbio,lip were below clip⇌sed, (2) there was proportionality between the two parameters with high R(2) values (0.92-1.00) and (3) the slopes of the linear regressions were very similar between the three stations (0.297; 0.327; 0.390). These results confirm the close link between PCB bioaccumulation and the thermodynamic potential of sediment-associated HOCs for partitioning into lipids. This novel approach gives clearer and more consistent results compared to conventional approaches that are based on total concentrations in sediment and biota-sediment accumulation factors. We propose to apply equilibrium sampling for determining bioavailability and bioaccumulation potential of HOCs, since this technique can provide a thermodynamic basis for the risk assessment and management of contaminated sediments.
Collapse
Affiliation(s)
- Sabine Schäfer
- Department of Qualitative Hydrology, Federal Institute of Hydrology, Am Mainzer Tor 1, 56068 Koblenz, Germany.
| | - Catherine Antoni
- Department of Qualitative Hydrology, Federal Institute of Hydrology, Am Mainzer Tor 1, 56068 Koblenz, Germany.
| | - Christel Möhlenkamp
- Department of Qualitative Hydrology, Federal Institute of Hydrology, Am Mainzer Tor 1, 56068 Koblenz, Germany.
| | - Evelyn Claus
- Department of Qualitative Hydrology, Federal Institute of Hydrology, Am Mainzer Tor 1, 56068 Koblenz, Germany.
| | - Georg Reifferscheid
- Department of Qualitative Hydrology, Federal Institute of Hydrology, Am Mainzer Tor 1, 56068 Koblenz, Germany.
| | - Peter Heininger
- Department of Qualitative Hydrology, Federal Institute of Hydrology, Am Mainzer Tor 1, 56068 Koblenz, Germany.
| | - Philipp Mayer
- Department of Environmental Engineering, Technical University of Denmark, Kongens Lyngby, Denmark.
| |
Collapse
|
8
|
Höss S, Ahlf W, Bergtold M, Bluebaum-Gronau E, Brinke M, Donnevert G, Menzel R, Möhlenkamp C, Ratte HT, Traunspurger W, von Danwitz B, Pluta HJ. Interlaboratory comparison of a standardized toxicity test using the nematode Caenorhabditis elegans (ISO 10872). Environ Toxicol Chem 2012; 31:1525-1535. [PMID: 22544597 DOI: 10.1002/etc.1843] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2011] [Revised: 01/20/2012] [Accepted: 02/09/2012] [Indexed: 05/31/2023]
Abstract
A ring test was carried out within the standardization process of ISO 10872 to evaluate the precision of the toxicity test for the nematode Caenorhabditis elegans. Eight different laboratories tested aqueous solutions of the reference substance benzylcetyldimethylammonium chloride as well as native sediments and soils for toxic effects on the growth and reproduction of C. elegans. Validity criteria were met in all laboratories. Average median- and low-effect concentrations were determined to be 15.1 mg L(-1) (EC50) and 8.7 mg L(-1) (EC10) for growth and 7.5 mg L(-1) (EC50) and 3.8 mg L(-1) (EC10) for reproduction of C. elegans, with ECx values showing a high degree of reproducibility (CV(R) : <21% and <11% for EC10 and EC50, respectively) and repeatability (CV(r) : <20% and <7% for EC10 and EC50, respectively). The toxic effects of the sediments and soils revealed by the different laboratories were well related to each samples' degree of chemical contamination. Moreover, the effects showed an acceptable reproducibility (CV(R) : 5-33% and 0-28% for growth and reproduction, respectively) and repeatability (CV(r) : 3-13% and 0-12% for growth and reproduction, respectively). The present study confirms that the toxicity test with C. elegans according to ISO 10872 is a reliable and precise tool to assess the toxicity of aqueous media, freshwater sediments, and soils.
Collapse
|
9
|
Schäfer S, Hamer B, Treursić B, Möhlenkamp C, Spira D, Korlević M, Reifferscheid G, Claus E. Comparison of bioaccumulation and biomarker responses in Dreissena polymorpha and D. bugensis after exposure to resuspended sediments. Arch Environ Contam Toxicol 2012; 62:614-627. [PMID: 22231661 DOI: 10.1007/s00244-011-9735-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2011] [Accepted: 11/17/2011] [Indexed: 05/31/2023]
Abstract
The zebra mussel Dreissena polymorpha is widely used as sentinel organism for the assessment of environmental contamination in freshwater environments. However, in the River Rhine (Germany), the D. polymorpha population is declining, whereas the closely related quagga mussel D. bugensis is found in high numbers at some sites. In the present laboratory study, D. polymorpha and D. bugensis were exposed to resuspended native sediments for ≤2 weeks. Wet sediments (<63 μm, 100 mg l(-1) dry weight) were used as surrogate suspended particulate matter to mimic one of the mussels' main uptake route for chemicals. The sediments were sampled in (1) the River Elbe in Dessau, a site known to be highly polluted with, e.g., organochlorine (OC) pesticides and (2) at a relatively unpolluted site in Havelberg in the River Havel, one of the Elbe's tributaries. Chemical analysis of persistent OC compounds (seven polychlorinated biphenyls [PCBs], DDT and its metabolites (DDX), hexachlorocylohexanes [HCHs], and hexachlorobenzene [HCB]) in soft tissue of mussels showed significantly greater values of PCBs 101, 118, 153, 138, 180, the sum of seven PCBs, and p,p'-DDD in D. bugensis compared with D. polymorpha. Fourteen days of exposure to Dessau sediment increased the concentration of p,p'-DDE and p,p'-DDD, as well as the sum of DDX, in both species compared with Havelberg sediment. Interspecific differences were less pronounced when regarding chemical concentrations with lipid content instead of dry-weight of tissue because D. bugensis had greater levels of total lipid than D. polymorpha. DNA damage in gills, as measured with the comet assay, was greater in D. bugensis compared with D. polymorpha. Simultaneously, the content of heat-shock protein (hsp70) in gills was greater in D. polymorpha than in D. bugensis. DNA damage and hsp70 were not induced by exposure time or sediment type. This study shows that D. bugensis and D. polymorpha may differ in their bioaccumulation potential of OC pesticides as well as their levels of DNA damage and hsp70. Therefore, more investigations are needed before quagga mussel can be used as alternative test organism for the zebra mussel.
Collapse
Affiliation(s)
- S Schäfer
- Federal Institute of Hydrology, Koblenz, Germany.
| | | | | | | | | | | | | | | |
Collapse
|