1
|
Roifman syndrome: a description of further immunological and radiological features. BMJ Case Rep 2022; 15:e249109. [PMID: 35450878 PMCID: PMC9024203 DOI: 10.1136/bcr-2022-249109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/02/2022] [Indexed: 11/03/2022] Open
Abstract
Roifman syndrome is a rare autosomal recessive inherited syndromic immunodeficiency. We wish to add to the available literature by reporting two brothers with clinical, radiological and immunological features of Roifman syndrome, confirmed on whole exome sequencing. We report an excellent response to subcutaneous immunoglobulin therapy in both brothers, reducing infection burden and hospital admissions. New radiological features are also described here which may assist in the diagnosis of other patients.
Collapse
|
2
|
Ultra-low-dose thoracic CT with model-based iterative reconstruction (MBIR) in cystic fibrosis patients undergoing treatment with cystic fibrosis transmembrane conductance regulators (CFTR). Clin Radiol 2021; 76:393.e9-393.e17. [PMID: 33468311 DOI: 10.1016/j.crad.2020.12.003] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Accepted: 12/11/2020] [Indexed: 01/10/2023]
Abstract
AIM To assess the utility of a volumetric low-dose computed tomography (CT) thorax (LDCTT) protocol at a dose equivalent to a posteroanterior (PA) and lateral chest radiograph for surveillance of cystic fibrosis (CF) patients. MATERIALS AND METHODS A prospective study was undertaken of 19 adult patients with CF that proceeded to LDCTT at 12 and 24 months following initiation of ivacaftor. A previously validated seven-section, low-dose axial CT protocol was used for the 12-month study. A volumetric LDCTT protocol was developed for the 24-month study and reconstructed with hybrid iterative reconstruction (LD-ASIR) and pure iterative reconstruction (model-based IR [LD-MBIR]). Radiation dose was recorded for each scan. Image quality was assessed quantitatively and qualitatively, and disease severity was assessed using a modified Bhalla score. Statistical analysis was performed and p-values of <0.05 were considered statistically significant. RESULTS Volumetric LD-MBIR studies were acquired at a lower radiation dose than the seven-section studies (0.08 ± 0.01 versus 0.10 ± 0.02 mSv; p=0.02). LD-MBIR and seven-section ASIR images had significantly lower levels of image noise compared with LD-ASIR images (p<0.0001). Diagnostic acceptability scores and depiction of bronchovascular structures were found to be acceptable for axial and coronal LD-MBIR images. LD-MBIR images were superior to LD-ASIR images for all qualitative parameters assessed (p<0.0001). No significant change was observed in mean Bhalla score between 1-year and 2-year studies (p=0.84). CONCLUSIONS The use of a volumetric LDCTT protocol (reconstructed with pure IR) enabled acquisition of diagnostic quality CT images, which were considered extremely useful for surveillance of CF patients, at a dose equivalent to a PA and lateral chest radiograph.
Collapse
|
3
|
Radiation dose tracking in computed tomography: Red alerts and feedback. Implementing a radiation dose alert system in CT. Radiography (Lond) 2020; 27:67-74. [PMID: 32693990 DOI: 10.1016/j.radi.2020.06.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Revised: 06/05/2020] [Accepted: 06/08/2020] [Indexed: 01/03/2023]
Abstract
INTRODUCTION This study investigates instances of elevated radiation dose on a radiation tracking system to determine their aetiologies. It aimed to investigate the impact of radiographer feedback on these alerts. METHODS Over two six-month periods 11,298 CT examinations were assessed using DoseWatch. Red alerts (dose length products twice the median) were identified and two independent reviewers established whether alerts were true (unjustifiable) or false (justifiable). During the second time period radiographers used a feedback tool to state the cause of the alert. A Chi-Square test was used to assess whether red alert incidence decreased following the implementation of radiographer feedback. RESULTS There were 206 and 357 alerts during the first and second time periods, respectively. These occurred commonly with CT pulmonary angiography, brain, and body examinations. Procedural documentation errors and patient size accounted for 57% and 43% of false alerts, respectively. Radiographer feedback was provided for 17% of studies; this was not associated with a significant change in the number of alerts, but the number of true alerts declined (from 7 to 3) (χ2 = 4.14; p = 0.04). CONCLUSION Procedural documentation errors as well as patient-related factors are associated with false alerts in DoseWatch. Implementation of a radiographer feedback tool reduced true alerts. IMPLICATIONS FOR PRACTICE The implementation of a radiographer feedback tool reduced the rate of true dose alerts. Low uptake with dose alert systems is an issue; the workflow needs to be considered to address this.
Collapse
|
4
|
A phantom study of the performance of model-based iterative reconstruction in low-dose chest and abdominal CT: When are benefits maximized? Radiography (Lond) 2019; 24:345-351. [PMID: 30292504 DOI: 10.1016/j.radi.2018.04.010] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2018] [Revised: 03/26/2018] [Accepted: 04/23/2018] [Indexed: 01/09/2023]
Abstract
INTRODUCTION The aim of this study was to assess and compare the effects of CT image reconstruction techniques on low-dose CT image quality using phantoms. METHODS Anthropomorphic torso and spatial/contrast-resolution phantoms were scanned at decreasing tube currents between 400 and 10 mA. CT thorax and abdomen/pelvis series were reconstructed with filtered back projection (FBP) alone, combined 40% adaptive statistical iterative reconstruction & FBP (ASIR40), and model-based iterative reconstruction (MBIR) [(resolution-preference 05 (RP05) and RP20 in the thorax and RP05 and noise-reduction 05 (NR05) in the abdomen)]. Two readers rated image quality quantitatively and qualitatively. RESULTS In thoracic CT, objective image noise on MBIR RP05 data sets outperformed FBP at 200, 100, 50 and 10 mA and outperformed ASIR40 at 50 and 10 mA (p < 0.001). MBIR RP20 outperformed FBP at 50 and 10 mA and outperformed ASIR40 at 10 mA (p < 0.001). Compared with both FBP and ASIR40, MBIR RP05 demonstrated significantly better signal-to-noise ratio (SNR) at 10 mA. In abdomino-pelvic CT, MBIR RP05 and NR05 outperformed FBP and ASIR at all tube current levels for objective image noise. NR05 demonstrated greater SNR at 200, 100, 50 and 10 mA and RP05 demonstrated greater SNR at 50 and 10 mA compared with both FBP and ASIR. MBIR images demonstrated better subjective image quality scores. Spatial resolution, low-contrast detectability and contrast-to-noise ratio (CNR) were comparable between image reconstruction techniques. CONCLUSION CTs reconstructed with MBIR have lower image noise and improved image quality compared with FBP and ASIR. These effects increase with reduced radiation exposure confirming optimal use for low-dose CT imaging.
Collapse
|
5
|
A comparison of embalming fluids on the structures and properties of tissue in human cadavers. Anat Histol Embryol 2018; 48:64-73. [PMID: 30450564 DOI: 10.1111/ahe.12412] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2018] [Revised: 10/02/2018] [Accepted: 10/09/2018] [Indexed: 12/11/2022]
Abstract
Cadaveric material has long been used to teach anatomy and more recently to train students in clinical skills. The aim of this study was to develop a systematic approach to compare the impact of four embalming solutions on the tissues of human cadavers. To this end, a formalin-based solution, Thiel, Genelyn and Imperial College London soft-preservation (ICL-SP) solution were compared. The effect of these chemicals on the properties of the tissue was assessed by measuring the range of motion (ROM) of joints and measuring the dimensions of different structures on computed tomography (CT) images before and after embalming. The mean changes in the ratio (angle to ROM) differed statistically between embalming methods (Welch Statistic 3,1.672 = 67.213, p = 0.026). Thiel embalmed cadavers showed an increase in range of motion while ICL-SP cadavers remained relatively the same. Genelyn and formalin embalmed cadavers registered a notable decrease in range of motion. Furthermore, investigation into the impact of the embalming chemicals on the dimensions of internal organs and vessels revealed that Thiel embalming technique leads to a decrease in the dimension of the cardiovascular system alone while formalin-based solutions maintain the shape of the organs and vessels investigated. Our findings suggest that the joints of cadavers' embalmed using ICL-SP technique may faithfully mimic that of unembalmed cadavers and that formalin is necessary to retain shape and size of the organs and vessels investigated in this study. Despite this, a study with larger numbers of cadavers is required to confirm these findings.
Collapse
|
6
|
Low-dose CT imaging of the acute abdomen using model-based iterative reconstruction: a prospective study. Emerg Radiol 2018; 26:169-177. [PMID: 30448900 DOI: 10.1007/s10140-018-1658-z] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2018] [Accepted: 11/09/2018] [Indexed: 01/07/2023]
Abstract
OBJECTIVES Performance of a modified abdominopelvic CT protocol reconstructed using full iterative reconstruction (IR) was assessed for imaging patients presenting with acute abdominal symptoms. MATERIALS AND METHODS Fifty-seven patients (17 male, 40 female; mean age of 56.5 ± 8 years) were prospectively studied. Low-dose (LD) and conventional-dose (CD) CTs were contemporaneously acquired between November 2015 and March 2016. The LD and CD protocols imparted radiation exposures approximating 10-20% and 80-90% those of routine abdominopelvic CT, respectively. The LD images were reconstructed with model-based iterative reconstruction (MBIR), and CD images with hybrid IR (40% adaptive statistical iterative reconstruction (ASIR)). Image quality was assessed quantitatively and qualitatively. Independent clinical interpretations were performed with a 6-week delay between reviews. RESULTS A 74.7% mean radiation dose reduction was achieved: LD effective dose (ED) 2.38 ± 1.78 mSv (size-specific dose estimate (SSDE) 3.77 ± 1.97 mGy); CD ED 7.04 ± 4.89 mSv (SSDE 10.74 ± 5.5 mGy). LD-MBIR images had significantly lower objective and subjective image noise compared with CD-ASIR (p < 0.0001). Noise reduction for LD-MBIR studies was greater for patients with BMI < 25 kg/m2 than those with BMI ≥ 25 kg/m2 (5.36 ± 3.2 Hounsfield units (HU) vs. 4.05 ± 3.1 HU, p < 0.0001). CD-ASIR studies had significantly better contrast resolution, and diagnostic acceptability (p < 0.0001 for all). LD-MBIR studies had significantly lower streak artifact (p < 0.0001). There was no difference in sensitivity for primary findings between the low-dose and conventional protocols with the exception of one case of enteritis. CONCLUSIONS Low-dose abdominopelvic CT performed with MBIR is a feasible radiation dose reduction strategy for imaging patients presenting with acute abdominal pain.
Collapse
|
7
|
Assessment of isocenter alignment during CT colonography: Implications for clinical practice. Radiography (Lond) 2018; 24:334-339. [DOI: 10.1016/j.radi.2018.04.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2017] [Revised: 04/06/2018] [Accepted: 04/09/2018] [Indexed: 11/30/2022]
|
8
|
Sarcopenia and Post-Operative Morbidity and Mortality in Patients with Gastric Cancer. J Gastric Cancer 2018; 18:242-252. [PMID: 30276001 PMCID: PMC6160525 DOI: 10.5230/jgc.2018.18.e25] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/27/2018] [Revised: 07/12/2018] [Accepted: 07/30/2018] [Indexed: 12/16/2022] Open
Abstract
Purpose Surgical resection for gastric adenocarcinoma is associated with significant post-operative morbidity and mortality. The aim of this study was to assess the prognostic significance of sarcopenia in patients undergoing resection for gastric adenocarcinoma with respect to post-operative morbidity and survival. Materials and Methods A retrospective analysis was conducted on a cohort of consecutive patients who underwent surgical resection for gastric adenocarcinoma between 2008 and 2014. Patient demographics, radiological parameters, and pathological data were collected. OsiriX software (Pixmeo) was used to measure skeletal muscle area, which was normalized for height to calculate skeletal muscle index. Results A total of 56 patients (41 male, 15 female; mean age, 68.4 ± 11.9 years) met the inclusion criteria. Of these, 36% (20 of 56) of the patients were sarcopenic pre-operatively. Both sarcopenic and non-sarcopenic patient groups were equally matched with the exception of weight and body mass index (P=0.036 and 0.001, respectively). Sarcopenia was associated with a decreased overall survival (log-rank P=0.003) and was an adverse prognostic predictor of overall survival in multivariate analysis (hazard ratio, 10.915; P=0.001). Sarcopenia was a predictor of serious in-hospital complications in multivariate analysis (odds ratio, 3.508; P=0.042). Conclusions In patients undergoing curative resection for gastric cancer, there was a statistically significant association between sarcopenia and both decreased overall survival and serious post-operative complications. The measurement and reporting of skeletal muscle index on pre-operative computed tomography should be considered.
Collapse
|
9
|
Tissue and Bronchoalveolar Lavage Biomarkers in Idiopathic Pulmonary Fibrosis Patients on Pirfenidone. Lung 2018; 196:543-552. [PMID: 30066212 DOI: 10.1007/s00408-018-0140-8] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2018] [Accepted: 06/27/2018] [Indexed: 10/28/2022]
Abstract
BACKGROUND Pirfenidone is a novel anti-fibrotic agent in idiopathic pulmonary fibrosis with proven clinical benefit. Better human tissue models to demonstrate the immunomodulatory and anti-fibrotic effect of pirfenidone are required. OBJECTIVES The purpose of the study was to use transbronchial lung cryobiopsy (TBLC), a novel technique which provides substantial tissue samples, and a large panel of biomarkers to temporally assess disease activity and response to pirfenidone therapy. METHODS Thirteen patients with confirmed idiopathic pulmonary fibrosis (IPF) underwent full physiological and radiological assessment at diagnosis and after 6-month pirfenidone therapy. They underwent assessment for a wide range of potential serum and bronchoalveolar lavage biomarkers of disease activity. Finally, they underwent TBLC before and after treatment. Tissue samples were assessed for numbers of fibroblast foci, for Ki-67, a marker of tissue proliferation and caspase-3, a marker of tissue apoptosis. RESULTS All patients completed treatment and investigations without significant incident. There was no significant fall in number of fibroblast foci per unit tissue volume after treatment (pre-treatment: 0.14/mm2 vs. post-treatment 0.08/mm2, p = 0.1). Likewise, there was no significant change in other markers of tissue proliferation, Ki-67 or Caspase-3 with pirfenidone treatment. We found an increase in three bronchoalveolar lavage angiogenesis cytokines, Placental Growth Factor, Vascular Endothelial Growth Factor-A, and basic Fibroblast Growth Factor, two anti-inflammatory cytokines Interleukin-10 and Interleukin-4 and Surfactant Protein-D. CONCLUSIONS TBLC offers a unique opportunity to potentially assess the course of disease activity and response to novel anti-fibrotic activity in IPF.
Collapse
|
10
|
Determination of a suitable low-dose abdominopelvic CT protocol using model-based iterative reconstruction through cadaveric study. J Med Imaging Radiat Oncol 2018; 62:625-633. [PMID: 29656596 DOI: 10.1111/1754-9485.12733] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2017] [Accepted: 03/08/2018] [Indexed: 11/29/2022]
Abstract
INTRODUCTION Cadaveric studies provide a means of safely assessing new technologies and optimizing scanning prior to clinical validation. Reducing radiation exposure in a clinical setting can entail incremental dose reductions to avoid missing important clinical findings. The use of cadavers allows assessment of the impact of more substantial dose reductions on image quality. Our aim was to identify a suitable low-dose abdominopelvic CT protocol for subsequent clinical validation. METHODS Five human cadavers were scanned at one conventional dose and three low-dose settings. All scans were reconstructed using three different reconstruction algorithms: filtered back projection (FBP), hybrid iterative reconstruction (60% FBP and 40% adaptive statistical iterative reconstruction (ASIR40)), and model-based iterative reconstruction (MBIR). Two readers rated the image quality both quantitatively and qualitatively. RESULTS Model-based iterative reconstruction images had significantly better objective image noise and higher qualitative scores compared with both FBP and ASIR40 images at all dose levels. The greatest absolute noise reduction, between MBIR and FBP, of 34.3 HU (equating to a 68% reduction) was at the lowest dose level. MBIR reduced image noise and improved image quality even in CT images acquired with a mean radiation dose reduction of 62% compared with conventional dose studies reconstructed with ASIR40, with lower levels of objective image noise, superior diagnostic acceptability and contrast resolution, and comparable subjective image noise and streak artefact scores. CONCLUSION This cadaveric study demonstrates that MBIR reduces image noise and improves image quality in abdominopelvic CT images acquired with dose reductions of up to 62%.
Collapse
|
11
|
Assessing radiological images of human cadavers: Is there an effect of different embalming solutions? ACTA ACUST UNITED AC 2017. [DOI: 10.1016/j.jofri.2017.08.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
12
|
|
13
|
Proliferative myositis of the latissimus dorsi presenting in a 20-year-old male athlete. IRISH MEDICAL JOURNAL 2017; 110:605. [PMID: 29341517] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
We describe the case of a 20-year-old rower presenting with an uncommon condition of Proliferative Myositis (PM) affecting the Latissimus Dorsi (LD). PM is a rare, benign tumour infrequently developing in the upper back. Its rapid growth and firm consistency may mistake it for sarcoma at presentation. Therefore, careful multidisciplinary work-up is crucial, and should involve appropriate radiological and histopathological investigations. Here, we propose the aetiology of LD PM to be persistent myotrauma induced by repetitive rowing motions. Symptoms and rate of progression ultimately determine the management which includes surveillance and/or conservative resection. There have been no documented cases of recurrence or malignant transformation.
Collapse
|
14
|
C-reactive protein and radiographic findings of lower respiratory tract infection in infants. World J Radiol 2017; 9:206-211. [PMID: 28529684 PMCID: PMC5415890 DOI: 10.4329/wjr.v9.i4.206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/14/2016] [Revised: 08/08/2016] [Accepted: 10/18/2016] [Indexed: 02/06/2023] Open
Abstract
AIM To evaluate the association between C-reactive protein (CRP) and radiological evidence of lower respiratory tract infection (LRTI) in infants.
METHODS All patients aged less than 4 years who presented with suspected lower respiratory tract infection, who received a peri-presentation chest radiograph and CRP blood measurement over an 18-mo period were included in the study. Age, gender, source of referral, CRP, white cell count, neutrophil count along with the patients’ symptoms and radiologist’s report were recorded.
RESULTS Three hundred and eleven patients met the inclusion criteria. Abnormal chest radiographs were more common in patients with elevated CRP levels (P < 0.01). Radiologic signs of LRTI were identified in 73.7% of chest radiographs when a patient had a CRP level between 50-99 mg/L. CRP levels were a better predictor of positive chest radiograph findings for those aged greater than I year compared to those 1 year or less.
CONCLUSION CRP may be used in patients with suspected LRTI diagnosis to select those who are likely to have positive findings on chest radiograph, thus reducing unnecessary chest radiographs.
Collapse
|
15
|
CT of the head for acute stroke: Diagnostic performance of a tablet computer prior to intravenous thrombolysis. J Med Imaging Radiat Oncol 2017; 61:334-338. [PMID: 28156051 DOI: 10.1111/1754-9485.12585] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2016] [Accepted: 12/08/2016] [Indexed: 11/30/2022]
Abstract
INTRODUCTION The authors propose that tablet computers could benefit patients with acute stroke in the remote care setting, where time to and accuracy of CT interpretation greatly influences patient outcome. METHODS One hundred and fifty consecutive patients who presented to the Emergency Department of a tertiary referral neurosciences centre within a time window suitable for intravenous thrombolytic therapy were included. Images were wirelessly transmitted to a tablet computer (iPad 3rd Generation, model = A1430, Apple, Cupertino, CA) and were reviewed by radiologists with three levels of experience for signs of intracranial haemorrhage, large vessel occlusion and parenchymal infarction. Reference standard interpretation was performed by two neuroradiologists using a diagnostic monochrome display. RESULTS Consensus neuroradiologist review on the tablet display found and correctly classified all of the 23 cases of intracranial haemorrhage including 21 cases of parenchymal haematoma, two cases of petechial haemorrhage and one patient with an acute subdural haematoma. Less experienced readers missed cases of petechial and subdural haematomas. There was excellent agreement between the tablet and diagnostic monochrome display in cases with no infarct or extensive parenchymal infarction. CONCLUSIONS Tablet computers can be used to facilitate rapid preliminary CT interpretation in patients with acute stroke in the remote setting.
Collapse
|
16
|
Computed tomography and patient risk: Facts, perceptions and uncertainties. World J Radiol 2016; 8:902-915. [PMID: 28070242 PMCID: PMC5183924 DOI: 10.4329/wjr.v8.i12.902] [Citation(s) in RCA: 124] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2016] [Revised: 08/29/2016] [Accepted: 10/24/2016] [Indexed: 02/06/2023] Open
Abstract
Since its introduction in the 1970s, computed tomography (CT) has revolutionized diagnostic decision-making. One of the major concerns associated with the widespread use of CT is the associated increased radiation exposure incurred by patients. The link between ionizing radiation and the subsequent development of neoplasia has been largely based on extrapolating data from studies of survivors of the atomic bombs dropped in Japan in 1945 and on assessments of the increased relative risk of neoplasia in those occupationally exposed to radiation within the nuclear industry. However, the association between exposure to low-dose radiation from diagnostic imaging examinations and oncogenesis remains unclear. With improved technology, significant advances have already been achieved with regards to radiation dose reduction. There are several dose optimization strategies available that may be readily employed including omitting unnecessary images at the ends of acquired series, minimizing the number of phases acquired, and the use of automated exposure control as opposed to fixed tube current techniques. In addition, new image reconstruction techniques that reduce radiation dose have been developed in recent years with promising results. These techniques use iterative reconstruction algorithms to attain diagnostic quality images with reduced image noise at lower radiation doses.
Collapse
|
17
|
Accurate tissue characterization in low-dose CT imaging with pure iterative reconstruction. J Med Imaging Radiat Oncol 2016; 61:190-196. [PMID: 27739229 DOI: 10.1111/1754-9485.12546] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2015] [Accepted: 09/09/2016] [Indexed: 11/28/2022]
Abstract
INTRODUCTION We assess the ability of low-dose hybrid iterative reconstruction (IR) and 'pure' model-based IR (MBIR) images to maintain accurate Hounsfield unit (HU)-determined tissue characterization. METHODS Standard-protocol (SP) and low-dose modified-protocol (MP) CTs were contemporaneously acquired in 34 Crohn's disease patients referred for CT. SP image reconstruction was via the manufacturer's recommendations (60% FBP, filtered back projection; 40% ASiR, Adaptive Statistical iterative Reconstruction; SP-ASiR40). MP data sets underwent four reconstructions (100% FBP; 40% ASiR; 70% ASiR; MBIR). Three observers measured tissue volumes using HU thresholds for fat, soft tissue and bone/contrast on each data set. Analysis was via SPSS. RESULTS Inter-observer agreement was strong for 1530 datapoints (rs > 0.9). MP-MBIR tissue volume measurement was superior to other MP reconstructions and closely correlated with the reference SP-ASiR40 images for all tissue types. MP-MBIR superiority was most marked for fat volume calculation - close SP-ASiR40 and MP-MBIR Bland-Altman plot correlation was seen with the lowest average difference (336 cm3 ) when compared with other MP reconstructions. CONCLUSIONS Hounsfield unit-determined tissue volume calculations from MP-MBIR images resulted in values comparable to SP-ASiR40 calculations and values that are superior to MP-ASiR images. Accuracy of estimation of volume of tissues (e.g. fat) using segmentation software on low-dose CT images appears optimal when reconstructed with pure IR.
Collapse
|
18
|
Effects of oral contrast on dose in abdominopelvic computed tomography with pure iterative reconstruction. World J Radiol 2016; 8:809-815. [PMID: 27721943 PMCID: PMC5039676 DOI: 10.4329/wjr.v8.i9.809] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2016] [Revised: 06/13/2016] [Accepted: 08/15/2016] [Indexed: 02/06/2023] Open
Abstract
AIM To assess the effect of neutral (NC) and positive (PC) oral contrast use on patient dose in low-dose abdominal computed tomography (CT).
METHODS Low-dose clinically indicated CTs were performed on 79 Crohn’s patients (35 = PC, 1 L 2% gastrografin; 44 = NC, 1.5 L polyethylene glycol). Scanner settings for both acquisitions were identical apart from 25 s difference in intravenous contrast timing. Body mass index (BMI), scan-ranges, dose-length product and size-specific dose estimated were recorded. Data was reconstructed with pure model-based iterative reconstruction. Image quality was objectively and subjectively analysed. Data analysis was performed with Statistical Package for Social Scientists.
RESULTS Higher doses were seen in neutral contrast CTs (107.60 ± 78.7 mGy.cm, 2.47 ± 1.21 mGy vs 85.65 ± 58.2 mGy.cm, 2.18 ± 0.96 mGy). The difference was significant in 2 of 4 BMI groups and in those that had both NC and PC investigations. Image-quality assessment yielded 6952 datapoints. NC image quality was significantly superior (P < 0.001) (objective noise, objective signal to noise ratio, subjective spatial resolution, subjective contrast resolution, diagnostic acceptability) at all levels. NC bowel distension was significantly (P < 0.001) superior.
CONCLUSION The use of polyethylene glycol as a neutral OC agent leads to higher radiation doses than standard positive contrast studies, in low dose abdominal CT imaging. This is possibly related to the osmotic effect of the agent resulting in larger intraluminal fluid volumes and resultant increased overall beam attenuation.
Collapse
|
19
|
P-212 An investigation of the association between sarcopenia and post-operative morbidity and mortality in patients with gastric cancer. Ann Oncol 2016. [DOI: 10.1093/annonc/mdw199.204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
20
|
MP366PERSISTENT POSTTRANSPLANT HYPERPARATHYROIDISM IS INDEPENDENTLY ASSOCIATED WITH LOSS OF MINERAL BONE DENSITY BY QUANTITATIVE CT. Nephrol Dial Transplant 2016. [DOI: 10.1093/ndt/gfw190.23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
21
|
Cumulative radiation exposure from diagnostic imaging in intensive care unit patients. World J Radiol 2016; 8:419-427. [PMID: 27158429 PMCID: PMC4840200 DOI: 10.4329/wjr.v8.i4.419] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2015] [Revised: 12/03/2015] [Accepted: 01/31/2016] [Indexed: 02/06/2023] Open
Abstract
AIM: To quantify cumulative effective dose of intensive care unit (ICU) patients attributable to diagnostic imaging.
METHODS: This was a prospective, interdisciplinary study conducted in the ICU of a large tertiary referral and level 1 trauma center. Demographic and clinical data including age, gender, date of ICU admission, primary reason for ICU admission, APACHE II score, length of stay, number of days intubated, date of death or discharge, and re-admission data was collected on all patients admitted over a 1-year period. The overall radiation exposure was quantified by the cumulative effective radiation dose (CED) in millisieverts (mSv) and calculated using reference effective doses published by the United Kingdom National Radiation Protection Board. Pediatric patients were selected for subgroup-analysis.
RESULTS: A total of 2737 studies were performed in 421 patients. The total CED was 1704 mSv with a median CED of 1.5 mSv (IQR 0.04-6.6 mSv). Total CED in pediatric patients was 74.6 mSv with a median CED of 0.07 mSv (IQR 0.01-4.7 mSv). Chest radiography was the most commonly performed examination accounting for 83% of all studies but only 2.7% of total CED. Computed tomography (CT) accounted for 16% of all studies performed and contributed 97% of total CED. Trauma patients received a statistically significant higher dose [median CED 7.7 mSv (IQR 3.5-13.8 mSv)] than medical [median CED 1.4 mSv (IQR 0.05-5.4 mSv)] and surgical [median CED 1.6 mSv (IQR 0.04-7.5 mSv)] patients. Length of stay in ICU [OR = 1.12 (95%CI: 1.079-1.157)] was identified as an independent predictor of receiving a CED greater than 15 mSv.
CONCLUSION: Trauma patients and patients with extended ICU admission times are at increased risk of higher CEDs. CED should be minimized where feasible, especially in young patients.
Collapse
|
22
|
Computed tomography dose optimisation in cystic fibrosis: A review. World J Radiol 2016; 8:331-341. [PMID: 27158420 PMCID: PMC4840191 DOI: 10.4329/wjr.v8.i4.331] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2015] [Revised: 10/15/2015] [Accepted: 01/19/2016] [Indexed: 02/06/2023] Open
Abstract
Cystic fibrosis (CF) is the most common autosomal recessive disease of the Caucasian population worldwide, with respiratory disease remaining the most relevant source of morbidity and mortality. Computed tomography (CT) is frequently used for monitoring disease complications and progression. Over the last fifteen years there has been a six-fold increase in the use of CT, which has lead to a growing concern in relation to cumulative radiation exposure. The challenge to the medical profession is to identify dose reduction strategies that meet acceptable image quality, but fulfil the requirements of a diagnostic quality CT. Dose-optimisation, particularly in CT, is essential as it reduces the chances of patients receiving cumulative radiation doses in excess of 100 mSv, a dose deemed significant by the United Nations Scientific Committee on the Effects of Atomic Radiation. This review article explores the current trends in imaging in CF with particular emphasis on new developments in dose optimisation.
Collapse
|
23
|
Comparison of MRI and high-resolution transvaginal sonography for the local staging of cervical cancer. JOURNAL OF CLINICAL ULTRASOUND : JCU 2016; 44:78-84. [PMID: 26294324 DOI: 10.1002/jcu.22288] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/02/2014] [Revised: 06/18/2015] [Accepted: 06/19/2015] [Indexed: 05/22/2023]
Abstract
PURPOSE The aim of this prospective study was to compare the diagnostic accuracy of transvaginal sonography (TVS) with that of MRI in the local staging of cervical cancer. METHODS All consecutive patients diagnosed with invasive carcinoma of the cervix over a 3-year period underwent MRI of the pelvis and TVS according to a standardized protocol. RESULTS In total, 46 patients were recruited to the study. We found a strong correlation between MRI and TVS in the assessment of tumor volume in both early-stage and advanced-stage disease (p < 0.0001). Both MRI and TVS had a sensitivity of 80%, a specificity of 50%, and a diagnostic accuracy of 63.6% for the detection of stromal invasion in early-stage disease. For the detection of parametrial invasion, we found sensitivity rates of 40% for MRI and 86% for TVS; specificity rates of 78.8% for MRI and 20% for TVS; and diagnostic accuracy rates of 89% for MRI and 78.7% for TVS. A matched-sample analysis revealed that there was no statistically significant difference between MRI and TVS in the assessment of stromal or parametrial invasion (p = 0.06). CONCLUSIONS TVS performed by a dedicated gynecologic radiologist is a feasible and economic imaging modality with a diagnostic accuracy comparable to that of MRI. It may be used as an adjunct to MRI for the local staging of invasive cervical cancer or to allow for rapid and confident triage of patients into operative and nonoperative categories for management in the gynecologic outpatient setting.
Collapse
|
24
|
Biomarkers to identify ILD and predict lung function decline in scleroderma lung disease or idiopathic pulmonary fibrosis. SARCOIDOSIS, VASCULITIS, AND DIFFUSE LUNG DISEASES : OFFICIAL JOURNAL OF WASOG 2015; 32:228-236. [PMID: 26422568] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Received: 09/14/2014] [Accepted: 02/05/2015] [Indexed: 06/05/2023]
Abstract
BACKGROUND SSc-ILD and IPF demonstrate significant morbidity and mortality. Predicting disease progression is challenging in both diseases. OBJECTIVES We sought a serum biomarker that could identify patients with SSc-ILD or IPF and prospectively predict short-term decline in lung function in these patients. METHODS 10 healthy controls, 5 SSc w/o ILD, 6 SSc-ILD and 13 IPF patients underwent venesection. An array of cytokines including KL-6, SP-D and MMP7 were measured. PFTs were obtained at baseline and six months. Cytokine measurements were correlated with PFTs. RESULTS KL-6 in IPF patients (633 ng/ml, IQR 492-1675) was significantly elevated compared to controls (198 ng/ml, IQR 52-360, p<0.01) and SSc w/o ILD patients (192 ng/ml, IQR 0-524, p<0.05); KL-6 in SSc-ILD patients (836 ng/ml, IQR 431-1303) was significantly higher than in controls (p<0.05). SP-D was significantly higher in IPF patients (542 ng/ml, IQR 305-577) compared to controls (137 ng/ml, IQR 97-284, p<0.01) or to SSc w/o ILD patients (169 ng/ml, IQR 137-219, p<0.05). In comparison with controls (0.0 ng/ml, IQR 0.0-0.6), MMP7 was significantly higher in both IPF patients (2.85 ng/ml, IQR 1.5-3.6, p<0.05) and SSc-ILD patients (5.41 ng/ml, IQR 2.6-7.2, p<0.001). Using a cut-off level of 459ng/ml for KL-6 and of 1.28 ng/ml for MMP7, 18 out of 19 patients with ILD had a serum value of either KL-6 or MMP7 above these thresholds. For all ILD patients, baseline serum SP-D correlated with ΔFVC %pred over six months (r=-0.63, p=0.005, 95% CI -0.85 to -0.24). CONCLUSIONS Combining KL-6 with MMP7 may be a useful screening tool for patients at risk of ILD. SP-D may predict short-term decline in lung function.
Collapse
|
25
|
Efficacy and Safety of Rituximab in Connective Tissue Disease related Interstitial Lung Disease. SARCOIDOSIS, VASCULITIS, AND DIFFUSE LUNG DISEASES : OFFICIAL JOURNAL OF WASOG 2015; 32:215-221. [PMID: 26422566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Received: 08/27/2014] [Revised: 03/03/2015] [Accepted: 03/03/2015] [Indexed: 06/05/2023]
Abstract
BACKGROUND Pulmonary complications of connective tissue disease are being identified more frequently with the advent of more sophisticated radiological investigations. Limited previous studies have suggested Rituximab (RTX), a chimeric monoclonal antibody with activity against CD-20, may benefit connective tissue disease patients with pulmonary complications. We performed a retrospective analysis of the efficacy and safety of RTX in patients attending a tertiary referral centre. METHODS Ten patients treated with RTX for pulmonary complications of CTD in our institution were identified. Baseline demographics, pre- and post-treatment investigations and adverse events were documented with an average follow up time-frame of 12.3 months (range: 3 - 27). Statistical analysis was performed using the Wilcoxan Signed-Rank test in SPSS. RESULTS There was a statistically significant improvement in pulmonary function, with a mean increase of 19% in DLCO (median DLCO (ml/min/mmHg) pre-treatment vs. post-treatment: 13.94 vs. 19.34, p=0.028) and a mean increase of 13% in FVC (median FVC (L) pre-treatment vs. post-treatment: 3.47 vs.3.6, p=0.28). For patients with pulmonary fibrosis (n=7), CT severity was improved on post-treatment scan, though this did not reach statistical significance. There was a reduction in the number of nodules seen on the follow-up scans of two patients without fibrosis. No patient had a severe adverse reaction to RTX. CONCLUSIONS Treatment with RTX resulted in an objective, measurable improvement in pulmonary function and/or radiological severity for the majority of patients included in the series. This was statistically significant despite the small numbers included. These results indicate a positive response to RTX with few complications of treatment.
Collapse
|
26
|
Haematuria: an imaging guide. Adv Urol 2014; 2014:414125. [PMID: 25136357 PMCID: PMC4124848 DOI: 10.1155/2014/414125] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2014] [Revised: 06/24/2014] [Accepted: 06/25/2014] [Indexed: 11/23/2022] Open
Abstract
This paper discusses the current status of imaging in the investigation of patients with haematuria. The physician must rationalize imaging so that serious causes such as malignancy are promptly diagnosed while at the same time not exposing patients to unnecessary investigations. There is currently no universal agreement about the optimal imaging work up of haematuria. The choice of modality to image the urinary tract will depend on individual patient factors such as age, the presence of risk factors for malignancy, renal function, a history of calculus disease and pregnancy, and other factors, such as local policy and practice, cost effectiveness and availability of resources. The role of all modalities, including conventional radiography, intravenous urography/excretory urography, ultrasonography, retrograde pyelography, multidetector computed tomography urography (MDCTU), and magnetic resonance urography, is discussed. This paper highlights the pivotal role of MDCTU in the imaging of the patient with haematuria and discusses issues specific to this modality including protocol design, imaging of the urothelium, and radiation dose. Examination protocols should be tailored to the patient while all the while optimizing radiation dose.
Collapse
|
27
|
Increasing the accuracy of 18F-FDG PET/CT interpretation of "mildly positive" mediastinal nodes in the staging of non-small cell lung cancer. Eur J Radiol 2014; 83:843-7. [PMID: 24581594 DOI: 10.1016/j.ejrad.2014.01.016] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2014] [Accepted: 01/20/2014] [Indexed: 12/01/2022]
Abstract
INTRODUCTION The aim of this study was to identify radiological factors that may reduce false-positive results and increase diagnostic accuracy when staging the mediastinum of patients with non-small cell lung carcinoma (NSCLC). METHODS This was a retrospective, interdisciplinary, per-node analysis study. We included patients with NSCLC and mediastinal nodes with an SUV max in the range of 2.5-4.0 on PET-CT. We hypothesized that the greatest number of false positive cases would occur in this cohort of patients. RESULTS A total of 92 mediastinal lymph nodes were analyzed in 44 patients. Mediastinal disease (N2/N3) was histologically confirmed in 15 of 44 patients and in 34 of 92 lymph nodes; positive predictive value of 37% and false positive rate of 63%. Lymph node SUV max, tumor size, ratio of node SUV max to tumor SUV max (SUVn/SUVp), and ratio of node SUV max to node size (SUV n/SADn) were significantly higher in true positive cases. Using a threshold of 0.3 for SUV node/tumor and 3 for SUV node/size yielded sensitivities of 91% and 71% and specificities of 71% and 69% respectively for the detection of mediastinal disease. Using both ratios in combination resulted in a sensitivity of 65% and a specificity of 88%. Concurrent benign lung disease was observed significantly more frequently in false-positive cases. CONCLUSION SUVn/SUVpt and SUVn/SADn may be complimentary to conventional visual interpretation and SUV max measurement in the assessment of mediastinal disease in patients with NSCLC.
Collapse
|
28
|
CT Densitometry as a Predictor of Pulmonary Function in Lung Cancer Patients. Open Respir Med J 2012; 6:139-44. [PMID: 23264834 PMCID: PMC3527876 DOI: 10.2174/1874306401206010139] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2012] [Revised: 10/16/2012] [Accepted: 11/14/2012] [Indexed: 12/03/2022] Open
Abstract
Purpose: Preoperative pulmonary assessment is undertaken in patients with resectable lung cancer to identify
those at increased risk of perioperative complications. Guidelines from the American College of Chest Physicians indicate
that if the FEV1 and DLCO are ≥60% of predicted, patients are suitable for resection without further evaluation.
The aim of our study is to determine if quantitative measures of lung volume and density obtained from pre-operative CT
scans correlate with pulmonary function tests. This may allow us to predict pulmonary function in patients with lung
cancer and identify patients who would tolerate surgical resection.
Materials and Methods: Patients were identified retrospectively from the lung cancer database of a tertiary hospital. Image
segmentation software was utilized to estimate total lung volume, normal lung volume (values -500 HU to -910 HU),
emphysematous volume (values less than -910 HU), and mean lung density from pre-operative CT studies for each patient
and these values were compared to contemporaneous pulmonary function tests.
Results: A total of 77 patients were enrolled. FEV1 was found to correlate significantly with the mean lung density
(r=.762, p<.001) and the volume of emphysema (r= -.678, p<.001). DLCO correlated significantly with the mean lung
density (r =.648, p<.001) and the volume of emphysematous lung (r= -.535, p<.001).
Conclusion: The results of this study suggest that both FEV1 and DLCO correlate significantly with volume of
emphysema and mean lung density. We now plan to prospectively compare these CT parameters with measures of good
and poor outcome postoperatively to identify CT measures that may predict surgical outcome preoperatively
Collapse
|
29
|
Progressive multifocal leucoencephalopathy in a patient with idiopathic CD4+ lymphocytopenia. IRISH MEDICAL JOURNAL 2012; 105:84-85. [PMID: 22558816] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Progressive multifocal leucoencephalopathy (PML) is an opportunistic, demyelinating neurological disease caused by reactivation of the JC polyomavirus. PML occurs almost exclusively in immunosuppressed individuals, with only isolated case reports of PML occurring in patients without apparent immunosuppression. Idiopathic CD4+ lymohocytopenia (ICL) is a syndrome defined by the Centre for Disease Control and Prevention as a CD4+ count <300 cells/uL or <20% of total T cell count on >1 occasion, with no evidence of human immunodeficiency virus (HIV) infection, and the absence of other known immunodeficiency or therapy associated with lymphocytopenia. We describe a case of PML occurring in a patient with idiopathic CD4+ lymphocytopenia.
Collapse
|
30
|
Randomized, double-blinded, placebo controlled study to assess the effect of topical 1% nicotinamide on actinic keratoses. Br J Dermatol 2010; 162:1138-9. [PMID: 20199551 DOI: 10.1111/j.1365-2133.2010.09659.x] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
31
|
Abstract
Dacron-reinforced Silastic sheets were removed from two patients who had previously undergone surgery for internal derangements of the temporomandibular joint. Excised tissue from around the joints was submitted for histological analysis, revealing a diagnosis of detritus synovitis. The significance of these findings with respect to the insertion of foreign material into the jaw joint is discussed in the light of recent research.
Collapse
|
32
|
Open bite. Aust Dent J 1987; 32:141-2. [PMID: 3476039 DOI: 10.1111/j.1834-7819.1987.tb05385.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
33
|
|
34
|
|
35
|
Internal derangements of the temporomandibular joint. II. Use of bone scanning as an aid to diagnosis. Aust Dent J 1985; 30:349-54. [PMID: 3879448 DOI: 10.1111/j.1834-7819.1985.tb02529.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|
36
|
|
37
|
|
38
|
|
39
|
Recent developments in interpositional bone-grafting of the atrophic mandible. JOURNAL OF MAXILLOFACIAL SURGERY 1985; 13:14-23. [PMID: 3884722 DOI: 10.1016/s0301-0503(85)80007-2] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
A clinical study on 54 patients, who underwent augmentation of the atrophic mandible by interposed bone-grafts, but in whom routine follow-up vestibuloplasty was deliberately avoided, is presented. The results show a reduced rate of bone resorption in the anterior region and less interference with lip and chin sensibility. An additional study is included concerning the fate of the elevated ridge and associated bone-graft in the body region posterior to the mental foramen. Results suggest that the resorption pattern in this area is very similar to that of a subperiosteal bone-graft. Modification of surgical technique in this regard has produced encouraging results.
Collapse
|
40
|
Abstract
The application of the posterior segmental maxillary osteotomy to the problem of edentulous space closure was studied in 30 patients so treated. The degree of success was based on several criteria, which included stability, periodontal health, occlusion, and response to treatment. A simplified surgical technique is described and useful surgical aids are demonstrated. The existing literature is reviewed in the light of present findings.
Collapse
|
41
|
Internal derangements of the temporomandibular joint. A review. ANNALS OF THE ROYAL AUSTRALASIAN COLLEGE OF DENTAL SURGEONS 1984; 8:106-26. [PMID: 6400070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
42
|
Surgical correction of vertical maxillary excess: a re-evaluation. JOURNAL OF MAXILLOFACIAL SURGERY 1982; 10:84-91. [PMID: 6954226 DOI: 10.1016/s0301-0503(82)80018-0] [Citation(s) in RCA: 28] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
Abstract
Correction of vertical maxillary excess by Le Fort I osteotomy has become a widely accepted practice. Although the downfracture method is used almost exclusively in most major centres, the total maxillary alveolar osteotomy still has its advocates. Two patients surgically treated by total maxillary alveolar osteotomy and presented in this journal are re-evaluated with respect to the long-term stability of maxillary intrusion. Literature pertaining to the stability of the maxilla following intrusion by Le Fort I osteotomy and after various combinations of anterior and posterior maxillary ostectomy is reviewed. The advantages of the downfracture method are discussed. An alternative method of achieving the desired degree of intrusion is presented, which ensures more intimate bone contact.
Collapse
|
43
|
The origin of the Le Fort I maxillary osteotomy: Cheever's operation. JOURNAL OF ORAL SURGERY (AMERICAN DENTAL ASSOCIATION : 1965) 1981; 39:731-4. [PMID: 7024489] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
The Le Fort I maxillary osteotomy so commonly performed today for a variety of reasons had its primitive beginnings in 1867 in the search for a more simple, direct, and less mutilating approach to the nasal cavity for tumor removal. David Cheever, firstly by his successfully repeated downfracture of the right hemimaxilla in one patient, who had complete recovery, followed by the technically successful total maxillary downfracture (although the patient died postoperatively), must occupy a foundation position in the history of the Le Fort I maxillary osteotomy.
Collapse
|