1
|
Patient-reported outcomes of neurologic and neuropsychiatric symptoms in mild COVID-19: a prospective cohort study. CMAJ Open 2023; 11:E696-E705. [PMID: 37553227 PMCID: PMC10414975 DOI: 10.9778/cmajo.20220248] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/10/2023] Open
Abstract
BACKGROUND Various neurologic manifestations have been reported in patients with COVID-19, mostly in retrospective studies of patients admitted to hospital, but there are few data on patients with mild COVID-19. We examined the frequency and persistence of neurologic/neuropsychiatric symptoms in patients with mild COVID-19 in a 1-year prospective cohort study, as well as assessment of use of health care services and patient-reported outcomes. METHODS Participants in the Alberta HOPE COVID-19 trial (hydroxychloroquine v. placebo for 5 d), managed as outpatients, were prospectively assessed 3 months and 1 year after their positive test result. They completed detailed neurologic/neuropsychiatric symptom questionnaires, the telephone version of the Montreal Cognitive Assessment (T-MoCA), the Kessler Psychological Distress Scale (K10) and the EuroQol EQ-5D-3L (measure of quality of life). Close informants completed the Mild Behavioural Impairment Checklist (MBI-C) and the Informant Questionnaire on Cognitive Decline in the Elderly. We also tracked use of health care services and neurologic investigations. RESULTS The cohort consisted of 198 participants (87 female [43.9%] median age 45 yr, interquartile range 37-54 yr). Of the 179 participants with symptom assessments, 139 (77.6%) reported at least 1 neurologic symptom, the most common being anosmia/dysgeusia (99 [55.3%]), myalgia (76 [42.5%]) and headache (75 [41.9%]). Forty patients (22.3%) reported persistent symptoms at 1 year, including confusion (20 [50.0%]), headache (21 [52.5%]), insomnia (16 [40.0%]) and depression (14 [35.0%]); 27/179 (15.1%) reported no improvement. Body mass index (BMI), a history of asthma and lack of full-time employment were associated with the presence and persistence of neurologic/neuropsychiatric symptoms; female sex was independently associated with both (presence: odds ratio [OR] adjusted for age, race, BMI, history of asthma and neuropsychiatric history 5.04, 95% confidence interval [CI] 1.58 to 16.10). Compared to participants without persistent symptoms, those with persistent symptoms had more hospital admissions and family physician visits, and worse MBI-C scores and less frequent independence for instrumental activities at 1 year (83.8% v. 97.8%, p = 0.005). Patients with any or persistent neurologic symptoms had worse psychologic distress (K10 score ≥ 20: adjusted OR 12.1, 95% CI 1.4 to 97.2) and quality of life (median EQ-5D-3L visual analogue scale rating 75 v. 90, p < 0.001); 42/84 (50.0%) had a T-MoCA score less than 18 at 3 months, as did 36 (42.9%) at 1 year. Participants who reported memory loss were more likely than those who did not report such symptoms to have informant-reported cognitive-behavioural decline (1-yr MBI-C score ≥ 6.5: adjusted OR 15.0, 95% CI 2.42 to 92.60). INTERPRETATION Neurologic/neuropsychiatric symptoms were commonly reported in survivors of mild COVID-19, and they persisted in 1 in 5 patients 1 year later. Symptoms were associated with worse participant- and informant-reported outcomes. Trial registration: ClinicalTrials.gov, no. NCT04329611.
Collapse
|
2
|
Design and testing of the safety of the SARUS-CPR hood for novice resuscitators. Scott Med J 2022; 67:189-195. [PMID: 35818757 DOI: 10.1177/00369330221112186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
BACKGROUND AND AIMS Bystanders should be protected against aerosols, droplets, saliva, blood and vomitus during resuscitation after cardiac arrest The SARUS (safer - airway - resuscitation) CPR airway hood™ is a clear plastic cover and integrated mask that envelopes the head and torso. Our objectives were to test leakage using saline aerosol generation tests, then assess the performance of the hood during mock cardio-pulmonary resuscitation on a manikin. METHODS A checklist was validated by comparing the performance of 10 novices against 10 experts during mock resuscitation. Thereafter, 15 novices were tested with and without the hood, in a randomised cross-over study, one week apart. RESULTS Laboratory analysis showed a > 99% reduction of saline particles detected 5 cm, 75 cm and 165 cm above volunteers wearing the hood. On manikins, experts scored better compared to novices, 8.5 (0.7) vs 7.6 (1.2), difference (95%CI) 0.9 (0.4-1.3), P = 0.0004. Novice performance was equivalent using the hood and standard equipment, 7.3 (1.4) vs 7.3 (1.1) respectively, difference (90%CI) 0.0 (-0.3 - 0.3), P = 0.90. CONCLUSION Aerosol transmission reduced in the breathing zone. Simulated resuscitation by novices was equivalent with and without the hood.
Collapse
|
3
|
Sleep-wake states change the interictal localization of candidate epileptic source generators. Sleep 2022; 45:6547903. [PMID: 35279715 PMCID: PMC9189983 DOI: 10.1093/sleep/zsac062] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2021] [Revised: 02/28/2022] [Indexed: 11/12/2022] Open
Abstract
STUDY OBJECTIVES To compare estimated epileptic source localizations from 5 sleep-wake states (SWS): wakefulness (W), rapid eye movement sleep (REM), and non-REM 1-3. METHODS Electrical source localization (sLORETA) of interictal spikes from different SWS on surface EEG from the epilepsy monitoring unit at spike peak and take-off, with results mapped to individual brain models for 75% of patients. Concordance was defined as source localization voxels shared between 2 and 5 SWS, and discordance as those unique to 1 SWS against 1-4 other SWS. RESULTS 563 spikes from 16 prospectively recruited focal epilepsy patients across 161 day-nights. SWS exerted significant differences at spike peak but not take-off. Source localization size did not vary between SWS. REM localizations were smaller in multifocal than unifocal patients (28.8% vs. 54.4%, p = .0091). All five SWS contributed about 45% of their localizations to converge onto 17.0 ± 15.5% voxels. Against any one other SWS, REM was least concordant (54.4% vs. 66.9%, p = .0006) and most discordant (39.3% vs. 29.6%, p = .0008). REM also yielded the most unique localizations (20.0% vs. 8.6%, p = .0059). CONCLUSIONS REM was best suited to identify candidate epileptic sources. sLORETA proposes a model in which an "omni-concordant core" of source localizations shared by all five SWS is surrounded by a "penumbra" of source localizations shared by some but not all SWS. Uniquely, REM spares this core to "move" source voxels from the penumbra to unique cortex not localized by other SWS. This may reflect differential intra-spike propagation in REM, which may account for its reported superior localizing abilities.
Collapse
|
4
|
The use of artificial intelligence and robotics in regional anaesthesia. Anaesthesia 2021; 76 Suppl 1:171-181. [PMID: 33426667 DOI: 10.1111/anae.15274] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Accepted: 09/11/2020] [Indexed: 12/15/2022]
Abstract
The current fourth industrial revolution is a distinct technological era characterised by the blurring of physics, computing and biology. The driver of change is data, powered by artificial intelligence. The UK National Health Service Topol Report embraced this digital revolution and emphasised the importance of artificial intelligence to the health service. Application of artificial intelligence within regional anaesthesia, however, remains limited. An example of the use of a convoluted neural network applied to visual detection of nerves on ultrasound images is described. New technologies that may impact on regional anaesthesia include robotics and artificial sensing. Robotics in anaesthesia falls into three categories. The first, used commonly, is pharmaceutical, typified by target-controlled anaesthesia using electroencephalography within a feedback loop. Other types include mechanical robots that provide precision and dexterity better than humans, and cognitive robots that act as decision support systems. It is likely that the latter technology will expand considerably over the next decades and provide an autopilot for anaesthesia. Technical robotics will focus on the development of accurate sensors for training that incorporate visual and motion metrics. These will be incorporated into augmented reality and visual reality environments that will provide training at home or the office on life-like simulators. Real-time feedback will be offered that stimulates and rewards performance. In discussing the scope, applications, limitations and barriers to adoption of these technologies, we aimed to stimulate discussion towards a framework for the optimal application of current and emerging technologies in regional anaesthesia.
Collapse
|
5
|
Novel approaches to needle tracking and visualisation. Anaesthesia 2021; 76 Suppl 1:160-170. [PMID: 33426657 DOI: 10.1111/anae.15232] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/17/2020] [Indexed: 12/22/2022]
Abstract
The accuracy and reliability of ultrasound are still insufficient to guarantee complete and safe nerve block for all patients. Injection of local anaesthetic close to, but not touching, the nerve is key to outcomes, but the exact relationship between the needle tip and nerve epineurium is difficult to evaluate, even with ultrasound. Ultrasound has insufficient resolution, tissues are difficult to discern due to acoustic impedance and needles are more difficult to see with increased angulation. The limitations of ultrasound have shifted the focus of innovation towards bio-markers that help detect needle tip position by utilising the physical properties of tissues, (e.g. pressure, electrical, optics, acoustic and elastic). Although most are at the laboratory stage and results are as yet only available from phantom or cadaver studies, clinical trials are imminent. For example, fine optical fibres placed within the lumen of block needles can measure needle tip pressure. Electrical impedance differentiates between intraneural and perineural needle tip placement. A new tip tracker needle has a piezo element embedded at its distal end that tracks the needle tip in-plane and out-of-plane as a blue/red or green circle depending on its relative location within the beam. Micro-ultrasound at the tip of the needle is in development. Early images using 40MHz in anaesthetised pigs reveal muscle striation, distinct epineurium and 30-40 fascicles > 75 micron in diameter. The next few years will see a technological revolution in tip-tracking technology that has the potential to improve patient safety and, in doing so, change practice.
Collapse
|
6
|
The effect of an ultrasound-activated needle tip tracker needle on the performance of sciatic nerve block on a soft embalmed Thiel cadaver. Anaesthesia 2020; 76:209-217. [PMID: 32797700 DOI: 10.1111/anae.15211] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/22/2020] [Indexed: 12/12/2022]
Abstract
In this study, we measured the performance of medical students and anaesthetists using a new tracker needle during simulated sciatic nerve block on soft embalmed cadavers. The tracker needle incorporates a piezo element near its tip that generates an electrical signal in response to insonation. A circle, superimposed on the ultrasound image surrounding the needle tip, changes size and colour according to the position of the piezo element within the ultrasound beam. Our primary objective was to compare sciatic block performance with the tracker switched on and off. Our secondary objectives were to record psychometrics, procedure efficiency, participant self-regulation and focused attention using eye-tracking technology. Our primary outcome measures were the number of steps successfully performed and the number of errors committed during each block. Videos were scored by trained experts using validated checklists. Sequential tracker activation and deactivation was randomised equally within subjects. With needle activation, steps improved in 10 (25%) subjects and errors reduced in six (15%) subjects. The most important steps were: needle tip identification before injection, OR (95%CI) 2.12 (1.61-2.80; p < 0.001); and needle tip identification before advance of the needle, 1.80 (1.36-2.39; p < 0.001). The most important errors were: failure to identify the needle tip before injection, 2.40 (1.78-3.24; p < 0.001); and failure to quickly regain needle tip position when tip visibility was lost, 2.03 (1.5-2.75; p < 0.001). In conclusion, needle-tracking technology improved performance in a quarter of subjects.
Collapse
|
7
|
Can REM Sleep Localize the Epileptogenic Zone? A Systematic Review and Analysis. Front Neurol 2020; 11:584. [PMID: 32793089 PMCID: PMC7393443 DOI: 10.3389/fneur.2020.00584] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2020] [Accepted: 05/20/2020] [Indexed: 12/31/2022] Open
Abstract
Epilepsy is a common and debilitating neurological disease. When medication cannot control seizures in up to 40% of cases, surgical resection of epileptogenic tissue is a clinically and cost- effective therapy to achieve seizure freedom. To simultaneously resect minimal yet sufficient cortex, exquisite localization of the epileptogenic zone (EZ) is crucial. However, localization is not straightforward, given relative difficulty of capturing seizures, constraints of the inverse problem in source localization, and possible disparate locations of symptomatogenic vs. epileptogenic regions. Thus, attention has been paid to which state of vigilance best localizes the EZ, in the hopes that one or another sleep-wake state may hold the key to improved accuracy of localization. Studies investigating this topic have employed diverse methodologies and produced diverse results. Nonetheless, rapid eye movement sleep (REM) has emerged as a promising sleep-wake state, as epileptic phenomena captured in REM may spatially correspond more closely to the EZ. Cortical neuronal asynchrony in REM may spatially constrain epileptic phenomena to reduce propagation away from the source generator, rendering them of high localizing value. However, some recent work demonstrates best localization in sleep-wake states other than REM, and there are reports of REM providing clearly false localization. Moreover, synchronistic properties and basic mechanisms of human REM remain to be fully characterized. Amidst these uncertainties, there is an urgent need for recording and analytical techniques to improve accuracy of localization. Here we present a systematic review and quantitative analysis of pertinent literature on whether and how REM may help localize epileptogenic foci. To help streamline and accelerate future work on the intriguing anti-epileptic properties of REM, we also introduce a simple, conceptually clear set-theoretic framework to conveniently and rigorously describe the spatial properties of epileptic phenomena in the brain.
Collapse
|
8
|
An initial evaluation of the effect of a novel regional block needle with tip-tracking technology on the novice performance of cadaveric ultrasound-guided sciatic nerve block. Anaesthesia 2019; 75:80-88. [PMID: 31506921 DOI: 10.1111/anae.14851] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/14/2019] [Indexed: 11/28/2022]
Abstract
Visibility of the needle tip is difficult to maintain during ultrasound-guided nerve block. A new needle has been developed that incorporates a piezo element 2-2.3 mm from the tip, activated by ultrasound. The electrical signal manifests as a coloured circle surrounding the needle tip, and allows real-time tracking. We hypothesised that novice regional anaesthetists would perform nerve block better with the tracker turned on rather than off. Our primary objective was to evaluate the new needle by measuring the performance of novice anaesthetists conducting simulated sciatic block on the soft embalmed Thiel cadaver. Training consisted of a lecture, scanning in volunteers and practice on cadavers. Testing entailed scanning the sciatic nerve of a cadaver and conducting 20 in-plane sciatic blocks in the mid-to-upper thigh region. Subjects were randomised equally, in groups of five, according to the sequence: tracker on/off/on/off; or tracker off/on/off/on. Video recordings were assessed by six raters for steps performed correctly and errors committed. Eight subjects were recruited and 160 videos were analysed. Using the tracking needle, five correct steps improved and one error reduced. The benefits included: better identification of the needle tip before advancing the needle, OR (95%CI) 3.4 (1.6-7.7; p < 0.001); better alignment of the needle to the transducer, 3.1 (1.3-8.7; p = 0.009); and better visibility of the needle tip 3.0 (1.4-7.3; p = 0.005). In conclusion, use of the tracker needle improved the sciatic block performance of novices on the soft embalmed cadaver.
Collapse
|
9
|
A cadaver study comparing spread of dye and nerve involvement after three different quadratus lumborum blocks. Br J Anaesth 2016; 117:387-94. [PMID: 27543534 DOI: 10.1093/bja/aew224] [Citation(s) in RCA: 155] [Impact Index Per Article: 19.4] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/20/2016] [Indexed: 11/14/2022] Open
|
10
|
A comparison of the ease of tracheal intubation using a McGrath MAC(®) laryngoscope and a standard Macintosh laryngoscope. Anaesthesia 2015; 70:1281-5. [PMID: 26336853 DOI: 10.1111/anae.13209] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/09/2015] [Indexed: 11/30/2022]
Abstract
We compared the McGrath MAC(®) videolaryngoscope when used as both a direct and an indirect laryngoscope with a standard Macintosh laryngoscope in patients without predictors of a difficult tracheal intubation. We found higher median Intubation Difficulty Scores with the McGrath MAC as a direct laryngoscope, 1 (0-3 [0-5]) than when using it as an indirect videolaryngoscope, 0 (0-1 [0-5]) or when using the Macintosh laryngoscope, 0 (0-1 [0-5]), p = 0.04. This was mirrored in the subjective user reporting, scored out of 10, of difficulty for each method 3.0 (2.0-3.4 [0.5-80]); 2.0 (1.0-3.9 [0-70]) and 2.0 (1.0-3.3 [0-70]), respectively (p = 0.01). This difficulty is in part explained by the poorer laryngeal views recorded using the Cormack and Lehane classification system (p < 0.001) and reflected in the higher than normal operator force required (25%, 4%, 8% for each method, respectively, p < 0.001) and the increased use of rigid intubation aids (21%, 6%, 2%, respectively, p < 0.001). There was no difference between the groups in time taken to intubate or incidence of complications. There was no statistical difference in the performances as measured between the McGrath MAC used as an indirect videolaryngoscope and the Macintosh laryngoscope. We cannot recommend that the McGrath videolaryngoscope be used as a direct laryngscopic device in place of the Macintosh.
Collapse
|
11
|
Effect of intradermal anaesthesia on success rate and pain of intravenous cannulation: a randomized non-blind crossover study. Scott Med J 2012; 56:210-3. [PMID: 22089042 DOI: 10.1258/smj.2011.011160] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Intravenous cannulation is a commonly performed procedure. This study aimed to determine whether the success rate and pain of intravenous cannulation is affected by prior injection of intradermal lidocaine. Intravenous cannulation was performed twice in 45 healthy volunteers. Intradermal lidocaine was administered prior to one of these cannulations. The outcome measures were success or failure of cannulation, and pain of cannulation, measured with a 100 mm visual analogue pain scale. The success rate of intravenous cannulation with and without prior intradermal lidocaine was 54% and 76%, respectively. The difference was 22.0% (95% CI 1.5-27.8%; P = 0.03). Log-linear analysis for three-way interaction between the variables (outcome, vascular condition and use of lidocaine) showed a significant influence of vascular condition on outcome (G(2) 24.6, P < 0.001). The mean (SD) pain scores in the control and intervention group were 34.8 (21.0) and 13.6 (13.2) mm, respectively. The difference between the mean pain scores was 21.2 mm (95% CI 15.1-27.3 mm). In conclusion, the success rate of intravenous cannulation may be reduced with the use of intradermal lidocaine, but success rate is primarily dependent on vascular condition. Intradermal lidocaine achieves a clinically significant reduction in the pain of intravenous cannulation.
Collapse
|
12
|
Application of sonoelastography to regional anaesthesia: a descriptive study with the Thiel embalmed cadaver model. ULTRASOUND : JOURNAL OF THE BRITISH MEDICAL ULTRASOUND SOCIETY 2012. [DOI: 10.1258/ult.2011.011039] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Introduction Ultrasound-guided regional anaesthesia (UGRA) is being used increasingly in patients but varying patient characteristics make it difficult to visualize needles and spread of local anaesthetic fluid. Methods To evaluate the use of elastography for UGRA by performing ultrasound-guided nerve blocks in Thiel embalmed cadavers. Both upper limb and lower limb blocks were performed on cadavers with ultrasound guidance. B-mode and elastography images obtained on split screen were analysed. Results The B-mode images were superior compared with the ultrasound elastography images with respect to the anatomical details; however, dynamic changes such as fluid spread were visualized better with elastography. Conclusion The elastography images also had good dose response to the volume of the injectate implying its usefulness in detecting local anaesthetic spread when low volumes are used as test doses.
Collapse
|
13
|
Determination of the EC50 of levobupivacaine for femoral and sciatic perineural infusion after total knee arthroplasty. Br J Anaesth 2009; 102:528-33. [PMID: 19244263 DOI: 10.1093/bja/aep010] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Infusion of local anaesthetic through femoral and sciatic catheters is an accepted method of providing pain relief after knee arthroplasty. However, the minimum effective concentration of perineural local anaesthetics is not known. METHODS Twenty-four patients received femoral and sciatic perineural infusions of levobupivacaine in order to prevent pain relief after total knee arthroplasty. The primary endpoint of the study was patient request for analgesic rescue for anterior or posterior knee pain within the first 36 h of perineural infusion. Treatment was determined by the method of sequential allocation, with a dosing interval of 0.002% w/v. RESULTS Thirteen patients did not require rescue analgesia for anterior knee pain and 16 patients did not require rescue analgesia for posterior knee pain. Median duration of failed blocks until rescue analgesia was 25 h (24-27 h) for the femoral block and 27 h (24-29 h) for the sciatic block. The minimum concentration at which patients did not require rescue analgesia was 0.024% for the femoral nerve and 0.014% for the sciatic nerve. Comparison of EC(50) showed that local anaesthetic requirements were significantly (P=0.03) higher by a factor of 1.25 (95% CI 1.03-1.55) for the femoral compared with the sciatic nerve. CONCLUSIONS The EC(50) for femoral perineural infusion is greater than the EC(50) for sciatic perineural infusion.
Collapse
|
14
|
An isobolographic analysis of diamorphine and levobupivacaine for epidural analgesia in early labour. Br J Anaesth 2007; 98:497-502. [PMID: 17303622 DOI: 10.1093/bja/ael373] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Few data describe the pharmacological interactions between local anaesthetics and opioids. The aim of this study was to measure the median effective concentration (MEC) of diamorphine and levobupivacaine when given separately and as mixtures for epidural analgesia, and determine whether the combination is additive or synergistic. METHODS One hundred and twenty patients were enrolled in this prospective randomized, two-phase, double-blind study. In the first phase, 60 women were randomized to receive a fixed 20 ml volume of either levobupivacaine or diamorphine epidurally . Dosing was determined using up-down sequential allocation with testing intervals, respectively, of 0.01%w/v and 12.5 microg ml(-1). After estimations of the MEC of levobupivacaine and diamorphine, a further 60 patients were randomized in the second phase to one of the three mixtures: (a) diamorphine 70 microg ml(-1) (fixed) and levobupivacaine (testing interval 0.004%w/v, starting at 0.044%w/v); (b) levobupivacaine 0.044%w/v (fixed) and diamorphine (testing interval 7 microg ml(-1), starting at 70 microg ml(-1)); and (c) bivariate diamorphine and levobupivacaine (testing intervals of 7 microg ml(-1) and 0.004%w/v starting at 70 microg ml(-1) and 0.044% w/v respectively). RESULTS The MEC estimates from the first phase were 143.8 microg ml(-1) (95% CI 122.2-165.3) for diamorphine and 0.083%w/v (95% CI 0.071-0.095) for levobupivacaine. In the second phase, the MEC and interaction index (gamma) of the three combinations were: diamorphine 65.5 microg ml(-1) (56.8-74.2), gamma = 0.99; levobupivacaine 0.041%w/v (0.037-0.049), gamma = 0.98; and for the fixed combination diamorphine 69.5 microg ml(-1) (60.5-78.5) and levobupivacaine 0.044%w/v (0.039-0.049), gamma = 1.02. CONCLUSION The combination of diamorphine and levobupivacaine is additive and not synergistic when used for epidural analgesia in the first stage of labour.
Collapse
|
15
|
Abstract
The vasodilator properties of lidocaine are believed to be due mainly to the inhibition of action potentials via sodium channel blocking in vasoconstrictor sympathetic nerves. However, mechanisms involving the vascular endothelium may also play a role, and in this study we investigated the potential influences of nitric oxide release, the cyclo-oxygenase pathway and the beta-adrenoceptors of vascular smooth muscle. Laser Doppler imaging was used to measure microvascular blood flow responses to intradermal injection of lidocaine 2%, with or without the addition of preservatives, in eight healthy, male volunteers. Co-injection of the nitric-oxide-synthase inhibitor Nomega-nitro-L-arginine methyl ester caused a 60% reduction in the response after about 20 min, and this reduction was enhanced with the lidocaine solution containing the preservatives methylhydroxybenzoate and propylhydroxybenzoate. No reduction in response was seen after blocking the cyclo-oxygenase or beta-adrenoceptor pathways. Nitric oxide release contributes to the vasoactivity of lidocaine in human skin.
Collapse
|
16
|
Intermittent vs continuous administration of epidural ropivacaine with fentanyl for analgesia during labour †. Br J Anaesth 2006; 97:359-64. [PMID: 16849382 DOI: 10.1093/bja/ael157] [Citation(s) in RCA: 80] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Many years ago regular intermittent bolus administration of epidural local anaesthetic solution was recognized to produce more effective analgesia than continuous infusion, but only recently has the development of suitable pumps allowed the former technique's wider evaluation. METHODS In this randomized, double-blind trial, 40 primigravid patients had a lumbar epidural catheter inserted, and plain ropivacaine 0.2% 15-20 ml was titrated until analgesia and bilateral sensory block to T10 were produced (time zero). Patients were then given either an infusion of ropivacaine 2 mg ml(-1) with fentanyl 2 microg ml(-1) at 10 ml h(-1), or hourly boluses of 10 ml of the same solution. Pain, sensory block and motor block were measured frequently. If requested, additional 10 ml boluses of the study mixture were given for analgesia. RESULTS There were no differences between the two groups in patient characteristics, obstetric/neonatal outcome, or in sensory or motor block. A total of 12 (60%) patients in the continuous group required one or more additional boluses compared with 4 (20%) patients in the intermittent group (95% CI 9.6-61.7%, P=0.02). Therefore the intermittent group received a lower total drug dose than the infusion group (P=0.02). Duration of uninterrupted analgesia (time to first rescue bolus) was longer in the intermittent group (P<0.02). CONCLUSIONS The intermittent group required fewer supplementary injections and less drug to maintain similar pain scores, sensory and motor block compared with the continuous group. This represents a more efficacious mode of analgesia.
Collapse
|
17
|
Abstract
BACKGROUND In view of the wide variation in pain experience between patients, a clinical standard -- the time from the end of surgery to the first experience of pain -- was applied to 1359 consecutive patients in order to investigate whether the initial quality of epidural block has an effect on the overall quality of postoperative pain relief. METHODS Clinical data were recorded in 58,118 out of 72,412 h in 1359 patients, and transferred to a database. Data collected included pain scores on a four-point verbal rating scale; nausea and vomiting; motor block; sedation scores; systolic blood pressure <100 and <90 mm Hg; ventilatory frequency <10 and <8 bpm; and hourly epidural infusion rate. RESULTS As the time to first experience of pain increased from nil to >24 hours, the time from the first to last experience of pain shortened from 34 (19-50) h to 3 (1-12) h (p<0.001) and the proportion of patients receiving an epidural bolus decreased from 53 to 8% (p<0.001). Increases in the initial pain free time increased the proportion of patients with systolic BP<100 mmHg from 59 to 77%, (p<0.001) and increased the proportion of patients with respiratory rate <10 bpm from 13 to 26%, (p<0.001). CONCLUSION Extending pain relief for more than 12 h beyond the end of abdominal surgery significantly improves the overall quality of postoperative pain relief, but is associated with an increase in side-effects.
Collapse
|
18
|
|
19
|
Vasoactive characteristics of bupivacaine and levobupivacaine with and without adjuvant epinephrine in peripheral human skin. Br J Anaesth 2005; 94:662-7. [PMID: 15722384 DOI: 10.1093/bja/aei095] [Citation(s) in RCA: 55] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Epinephrine is added to local anaesthetic preparations to prolong their action and reduce their systemic absorption. Bupivacaine and levobupivacaine cause vasodilatation at clinical doses, but lower doses appear to cause vasoconstriction. The aim of this study was to characterize fully the vasoactive effects of these anaesthetics, using an objective measure of blood flow, and to assess the influence of adding epinephrine. METHODS Laser Doppler imaging was used to measure the forearm skin blood flow responses to intradermal injection of eight doses of bupivacaine and levobupivacaine in 10 healthy male volunteers. The doses tested ranged from 0.008% to 0.75%, and the five highest doses were administered both with and without adjuvant epinephrine 2.5 microg ml(-1). RESULTS The cumulative responses to the lower subclinical concentrations (0.008-0.0625%) of both anaesthetics were smaller than or similar to that produced by saline alone, indicating a net vasoconstrictive effect. Higher doses caused net vasodilatation, and the levobupivacaine responses were generally lower than the corresponding bupivacaine responses (P=0.022). Epinephrine 2.5 microg ml(-1) significantly reduced the responses to clinical doses of both drugs (P<0.001), producing net vasoconstriction. CONCLUSIONS Bupivacaine and levobupivacaine have a biphasic vascular effect when injected intradermally, with subclinical doses causing net vasoconstriction. The addition of epinephrine 2.5 microg ml(-1) decreases these responses markedly.
Collapse
|
20
|
Is the clinical efficacy of epidural diamorphine concentration-dependent when used as analgesia for labour? †. Br J Anaesth 2005; 94:229-33. [PMID: 15556964 DOI: 10.1093/bja/aei029] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND The physicochemical properties of diamorphine (3,6-diacetylmorphine) enhance its bioavailability compared with more lipid-soluble opioids when administered into the epidural space. However, the influence of concentration, volume or mass on the clinical efficacy of diamorphine is not known. METHOD In this double-blind, randomized, prospective study, 62 women in active labour and </=5 cm cervical dilatation were recruited to determine whether the mode of action of diamorphine in the epidural space is concentration-dependent. After insertion of a lumbar epidural catheter, patients received epidural diamorphine 3 mg either as a high-volume, low-concentration solution (group A) or a low-volume, high-concentration solution (group B). The concentration of diamorphine was determined by the response of the previous patient in the same group using up-down sequential allocation. Pain corresponding to the previous contraction was assessed using a 100-mm visual analogue score and effective analgesia was defined as </=10 mm within 30 min of epidural injection. RESULTS There was no significant difference in EC50 for diamorphine between the groups: the difference was 15.0 microg ml(-1) (95% CI -40.3 to 10.3). The EC50 for group A was 237.5 microg ml(-1) (95% CI 221.2 to 253.8) and the EC50 for group B was 252.5 microg ml(-1) (95% CI 232.2 to 272.8). The EC50 ratio was 0.95 (95% CI 0.87 to 1.06). The groups exhibited parallelism (P=0.98). The overall EC50 for all data was 244.2 microg ml(-1) (95% CI 230.8 to 257.2). CONCLUSION We conclude that diamorphine provides analgesia in labour by a concentration-dependent effect.
Collapse
|
21
|
Density of spinal anaesthetic solutions of bupivacaine, levobupivacaine, and ropivacaine with and without dextrose. Br J Anaesth 2004; 92:547-51. [PMID: 14766715 DOI: 10.1093/bja/aeh094] [Citation(s) in RCA: 67] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND Spread of intrathecal local anaesthetics is determined principally by baricity and position of the patient. Hypobaric solutions of bupivacaine are characterized by an unpredictable spread of sensory block whereas addition of dextrose 80 g ml(-1) provides a predictable spread but to high thoracic levels. In contrast, dextrose concentrations between 8 and 30 g ml(-1) have shown reliable and consistent spread for surgery. Hence, the aim of this study was to determine the density of bupivacaine, levobupivacaine, and ropivacaine with and without dextrose at both 23 and 37 degrees C before embarking on clinical studies. METHODS Density (g ml(-1)) was measured using the method of mechanical oscillation resonance, accurate to five decimal places on 1250 samples. 500 density measurements were performed in a randomized, blind fashion at 23 and 37 degrees C on 10 plain solutions of bupivacaine (2.5, 5, and 7.5 g ml(-1)) levobupivacaine (2.5, 5, and 7.5 g ml(-1)) and ropivacaine (2, 5, 7.5, and 10 g ml(-1)). Following this, 750 density measurements were taken at 23 and 37 degrees C on the 5 g ml(-1) solutions of bupivacaine, levobupivacaine, and ropivacaine with added dextrose (10, 20, 30, 50, and 80 g ml(-1)). RESULTS There was a linear relationship between density and dextrose concentration for all three local anaesthetics (R(2)=0.99) at 23 and 37 degrees C. The mean density of levobupivacaine 5 g ml(-1) was significantly greater than the densities of bupivacaine 5 g ml(-1) and ropivacaine 5 g ml(-1) after adjusting for dextrose concentration using analysis of covariance. This difference existed both at 23 and 37 degrees C. The mean (sd) density of levobupivacaine 7.5 g ml(-1) was 1.00056 (0.00003) g ml(-1), the lower 0.5% percentile (1.00047 g ml(-1)) lying above the upper limit of hypobaricity for all patient groups. CONCLUSIONS The density of local anaesthetics decreases with increasing temperature and increases in a linear fashion with the addition of dextrose. Levobupivacaine 5 g ml(-1) has a significantly higher density compared with bupivacaine 5 g ml(-1) and ropivacaine 5 g ml(-1) at 23 and 37 degrees C both with and without dextrose. Levobupivacaine 7.5 g ml(-1) is an isobaric solution within all patient groups at 37 degrees C [corrected]
Collapse
|
22
|
|
23
|
Abstract
We investigated the roles of the endothelial nitric oxide and cyclo-oxygenase pathways in mediating the vasoactivity of prilocaine in the skin. We injected prilocaine 1% intradermally into forearm skin of 10 healthy, male subjects. Nitric oxide synthesis was inhibited at a second site by co-injecting prilocaine with l-NAME 1%. We then repeated the injections while blocking the cyclo-oxygenase pathway with aspirin (4 x 600 mg). We measured blood flow responses to the injections using laser Doppler imaging. We found that, after the traumatic effects of injection had subsided, l-NAME reduced the vascular response to prilocaine by a third (p = 0.012), indicating an influence specifically on the drug response. Aspirin had no effect on the response (p = 0.588). We conclude that the vasoactive effects of prilocaine in human skin are mediated partly through the release of endothelial nitric oxide and, although other mechanisms might also be involved, the cyclo-oxygenase pathway does not appear to play a role.
Collapse
|
24
|
Spinal anaesthesia for Caesarean section with bupivacaine 5 mg ml(-1) in glucose 8 or 80 mg ml(-1). Br J Anaesth 2001; 86:805-7. [PMID: 11573587 DOI: 10.1093/bja/86.6.805] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
The standard spinal preparation of bupivacaine contains a high concentration of glucose (80 mg ml(-1)). However, the addition of only a small amount of glucose (8 mg ml(-1)) to plain solutions of bupivacaine results in a solution which, although no more than marginally hyperbaric, produces a more predictable block when used for spinal anaesthesia in non-pregnant patients. However, bupivacaine 5 mg ml(-1) in glucose 8 mg ml(-1) has a density [1.00164 (SD 0.00008) at 37 degrees C] which is relatively greater than that of the cerebrospinal fluid (CSF) of the pregnant patient at term (1.0003 at 37 degrees C) because CSF density decreases during pregnancy. Therefore, a double-blind, randomized, controlled study was carried out to compare intrathecal bupivacaine (glucose 8 mg ml(-1)) with bupivacaine (glucose 80 mg ml(-1)) in 40 pregnant patients at term. Although there was no difference between groups in onset of sensory block, dose of ephedrine or patient satisfaction, patients receiving bupivacaine (5 mg ml(-1)) with glucose (8 mg ml(-1)) had persistently higher sensory blocks between 60 and 120 min after intrathecal injection, suggesting that the spread of spinal solutions in the pregnant patient at term is not dependent on density.
Collapse
|
25
|
Abstract
Regional anaesthesia has seen the development of a new local anaesthetic: levobupivacaine. This review aims to outline the rationale underlying the development of levobupivacaine and to consider its place in modern regional anaesthesia.
Collapse
|
26
|
Skin blood flow changes in response to intradermal injection of bupivacaine and levobupivacaine, assessed by laser Doppler imaging. Reg Anesth Pain Med 2000; 25:626-31. [PMID: 11097672 DOI: 10.1053/rapm.2000.9853] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
BACKGROUND AND OBJECTIVES The vascular effects of local anesthetics are important determinants of their therapeutic activity. Drugs that vasoconstrict have the potential clinical advantages of limited systemic uptake and prolonged duration of effect. The aim of this study was to assess quantitatively the cutaneous vasoactivity of racemic bupivacaine and one of its enantiomers, levobupivacaine. METHODS Four concentrations of each drug (0.1 mL each of 0.125%, 0.25%, 0.5%, and 0.75%), as well as normal saline, were injected intradermally into randomly assigned sites on the forearms of 10 volunteers. We measured skin blood perfusion using laser Doppler imaging before injection and at 2.5, 10, 20, 40, 60, and 90 minutes thereafter. RESULTS Both drugs produced a rapid, dose-dependent increase in skin perfusion (P <.001). Saline also caused an increase in perfusion, although less sustained. By 40 minutes, most responses had returned to baseline levels. However, after this time, perfusion continued to decrease, below baseline, for both bupivacaine and levobupivacaine. The exception to this was 0.75% bupivacaine, the response to which was significantly higher than the same concentration of levobupivacaine over this later period (P <.05). CONCLUSIONS Bupivacaine and levobupivacaine both have a biphasic effect on skin microvessels. The vasoconstriction observed after 40 minutes may occur when the quantity of drug remaining at the administration site has decreased to a lower level. The continued vasodilatation caused by bupivacaine is more difficult to interpret. The results suggest that these local anesthetics cause vasodilatation at high doses and vasoconstriction at lower, subclinical doses. This hypothesis and the clinical relevance of these effects warrant further investigation.
Collapse
|
27
|
Comparison of 0.25% S(-)-bupivacaine with 0.25% RS-bupivacaine for epidural analgesia in labour. Br J Anaesth 1999; 83:750-5. [PMID: 10690138 DOI: 10.1093/bja/83.5.750] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
We have compared the efficacy of 0.25% S(-)-bupivacaine with 0.25% RS-bupivacaine in providing epidural analgesia for labour in a randomized, multicentre, double-blind study. Analgesia was initiated with 10 ml of the study solution and maintained with 10-ml top-ups. We studied 137 women and treatments were found to be equivalent for onset, duration and quality of block. Median onset of pain relief was 12 min for both drugs and median duration was 49 (range 3-129) min and 51 (7-157) min for S(-)-bupivacaine and RS bupivacaine, respectively. The estimated treatment difference for duration of pain relief was -4 (90% CI -13, 6) min. Thirty patients failed to achieve pain relief after the first injection (20 patients after S(-)-bupivacaine and 10 after RS-bupivacaine; P = 0.039). However, median duration of pain relief from the first top-up was 82 (range 3-164) min for S(-)-bupivacaine and 76 (22-221) min for RS-bupivacaine. There were no significant differences in the quality of analgesia, as assessed by the investigators. There were no significant differences in the extent of sensory block, percentage of patients with motor block or incidence of adverse events.
Collapse
|
28
|
Abstract
Postoperative pain relief is often inadequate. Ignorance and misconceptions about opioids by ward staff contribute to this poor management. The introduction of acute pain teams has done much to improve pain relief for patients. It may also have contributed to changes in attitudes and knowledge of medical and nursing staff. We questioned 48 doctors and nurses on their knowledge and beliefs about postoperative pain relief. Staff members were questioned on two units, one with access to an acute pain team and one without. Over half those on the unit using traditional postoperative care thought patients did not receive adequate pain relief (58%). In comparison, only one respondent from the unit with the pain team thought this was the case (P < 0.001). More staff members that had experience of patient-controlled analgesia (PCA) were optimistic about its benefits than those in the unit with no experience; they were also less concerned about possible side effects. Only one respondent on the unit using PCA thought it carried a risk of drug dependence, compared to over half (55%) of those on the unit with no experience in this technique (P < 0.001). Over two-thirds of staff familiar with PCA thought nursing workload had decreased. Acute pain teams have an important role in educating ward staff. The impact of establishing such teams on staff knowledge and attitudes needs further study to ensure that they can carry out this role most effectively.
Collapse
|
29
|
|
30
|
The MiniCAP III CO2 Detector: assessment of a device to distinguish oesophageal from tracheal intubation. Arch Emerg Med 1992; 9:373-6. [PMID: 1492900 PMCID: PMC1285912 DOI: 10.1136/emj.9.4.373] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
A new portable infra-red CO2 detector was assessed in 50 intubated patients. This device was 100% accurate in distinguishing between tracheal and oesophageal intubation when used by nursing and paramedic personnel.
Collapse
|
31
|
Patient attitudes to discussing life-sustaining treatment. ARCHIVES OF INTERNAL MEDICINE 1986; 146:1613-5. [PMID: 3729645] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
|
32
|
Mapping and fi character determination of R factors of Enterobacter cloacae Df13. Antonie Van Leeuwenhoek 1972; 38:391-415. [PMID: 4561898 DOI: 10.1007/bf02328110] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|