1
|
Combined Odontoid (C2) and Atlas (C1) Fractures in Geriatric Patients: A Systematic Review and Treatment Recommendation. Global Spine J 2023; 13:22S-28S. [PMID: 37084349 PMCID: PMC10177310 DOI: 10.1177/21925682221127951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/23/2023] Open
Abstract
STUDY DESIGN Systematic review. OBJECTIVE The aim of this study was to conduct a systematic overview of the pathogenesis and the treatment options of combined odontoid and atlas fractures in geriatric patients. METHODS This review is based on articles retrieved by a systematic search in the PubMed and Web of Science databases for articles published until February 2021 dealing with combination fractures of C1 and C2 in geriatric patients. RESULTS Altogether, 438 articles were retrieved from the literature search. A total of 430 articles were excluded. The remaining eight original articles were included in this systematic review depicting the topics pathogenesis, non-operative treatment, posterior approach, and anterior approach. The overall level of evidence of the studies is low. CONCLUSION Combined odontoid and atlas fractures in the geriatric population are commonly caused by simple falls and seem to be associated with atlanto-odontoid osteoarthritis. Non-operative treatment with a cervical orthosis is a feasible treatment option in the majority of patients with stable C2 fractures. In case of surgery posterior C1 and C 2 stabilization and anterior triple or quadruple screw fixation are possible techniques. Some patients may also deserve an occipito-cervical fusion. A possible treatment algorithm is proposed.
Collapse
|
2
|
Intraoperative revision rates due to three-dimensional imaging in orthopedic trauma surgery: results of a case series of 4721 patients. Eur J Trauma Emerg Surg 2023; 49:373-381. [PMID: 36048181 PMCID: PMC9925545 DOI: 10.1007/s00068-022-02083-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Accepted: 08/08/2022] [Indexed: 11/03/2022]
Abstract
PURPOSE Intraoperative 3D imaging has become a valued tool in assessing the quality of reduction and implant placement in orthopedic trauma surgery. In our institution, 3D imaging is used routinely since 2001. To evaluate the intraoperative findings and consequences of this technique, intraoperative revision rates in cases with 3D imaging were analyzed. METHODS All operative procedures carried out with intraoperative 3D imaging between August 2001 and December 2016 were included. The scans were assessed intraoperatively and documented thereafter. In case of malreduction or misplaced implants, an immediate revision was performed. The number of scans per case as well as the findings and consequences drawn regarding the anatomical region were analyzed. RESULTS 4721 cases with 7201 3D scans were included in this study. The most common anatomical regions were the ankle (22.3%), the calcaneus (14.8%) and the tibial head (9.5%). In 19.1% of all cases, an intraoperative revision was performed. The highest revision rates were found with 36.0% in calcaneal fractures, 24.8% in fractures of the tibial plateau, 22.3% in injuries of the ankle. In 52.0% of revisions, the reduction was improved regarding intra-articular steps or joint congruency. In 30.5% an implant was corrected. CONCLUSION Intraoperative revision due to results of 3D imaging was performed in almost one-fifth of cases. This illustrates the improved possibilities to detect malreduction and implant misplacements intraoperatively and thus the abilities to improve surgical outcome. LEVEL OF EVIDENCE III.
Collapse
|
3
|
Intraoperative Computed Tomography in Orthopaedic Trauma Surgery. ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE 2022; 160:407-413. [PMID: 33851403 DOI: 10.1055/a-1373-6492] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
BACKGROUND When using mobile 3D C-arms, impairments in image quality occur due to artefacts caused by metal implants as well as to the limited field of view. To avoid these restrictions, special computed tomography devices were designed, in order to improve image quality and to meet requirements for intraoperative usage. OBJECTIVES To analyse practicability and benefits of a mobile intraoperative CT device (Airo, Brainlab, Munich, Germany) on the basis of several parameters that were obtained during a 40-month period. MATERIALS AND METHODS All procedures that were performed with usage of intraoperative CT between January 2017 and April 2020 were analysed with respect to anatomical region, count of scans, duration of scans, consequences drawn from the scans and use of navigation. RESULTS 354 CT-scans were performed in 171 patients (mean 2.07 [1 - 6] scans per procedure). 47.81% of the procedures were spinal, 52.19% affected the pelvis. 83% of the procedures were navigated. In 22% of patients, improvement in implant placement or reduction was achieved; in most patients (55%), a guidewire for pedicle screws was corrected. The mean scan duration was 10.33 s (3.54 - 21.72). CONCLUSIONS Use of intraoperative CT was reliable and helpful. Integration in OR standards requires more effort than mobile 3D C-arms. Image quality was outstanding for intraoperative conditions and allowed proper assessment of implant placement and reduction in all cases. Due to the high financial outlay of the system and the good image quality of 3D C-arms in the extremities, we assume that this procedure can be applied in intraoperative CT in traumatological cases in spinal and pelvic surgery in high-level trauma centres.
Collapse
|
4
|
Fiducial marker recovery and detection from severely truncated data in navigation assisted spine surgery. Med Phys 2022; 49:2914-2930. [PMID: 35305271 DOI: 10.1002/mp.15617] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Revised: 02/16/2022] [Accepted: 03/06/2022] [Indexed: 11/11/2022] Open
Abstract
PURPOSE Fiducial markers are commonly used in navigation assisted minimally invasive spine surgery and they help transfer image coordinates into real world coordinates. In practice, these markers might be located outside the field-of-view (FOV) of C-arm cone-beam computed tomography (CBCT) systems used in intraoperative surgeries, due to the limited detector sizes. As a consequence, reconstructed markers in CBCT volumes suffer from artifacts and have distorted shapes, which sets an obstacle for navigation. METHODS In this work, we propose two fiducial marker detection methods: direct detection from distorted markers (direct method) and detection after marker recovery (recovery method). For direct detection from distorted markers in reconstructed volumes, an efficient automatic marker detection method using two neural networks and a conventional circle detection algorithm is proposed. For marker recovery, a task-specific data preparation strategy is proposed to recover markers from severely truncated data. Afterwards, a conventional marker detection algorithm is applied for position detection. The networks in both methods are trained based on simulated data. For the direct method, 6800 images and 10000 images are generated respectively to train the U-Net and ResNet50. For the recovery method, the training set includes 1360 images for FBPConvNet and Pix2pixGAN. The simulated data set with 166 markers and 4 cadaver cases with real fiducials are used for evaluation. RESULTS The two methods are evaluated on simulated data and real cadaver data. The direct method achieves 100% detection rates within 1 mm detection error on simulated data with normal truncation and simulated data with heavier noise, but only detect 94.6% markers in extremely severe truncation case. The recovery method detects all the markers successfully in three test data sets and around 95% markers are detected within 0.5 mm error. For real cadaver data, both methods achieve 100% marker detection rates with mean registration error below 0.2 mm. CONCLUSIONS Our experiments demonstrate that the direct method is capable of detecting distorted markers accurately and the recovery method with the task-specific data preparation strategy has high robustness and generalizability on various data sets. The task-specific data preparation is able to reconstruct structures of interest outside the FOV from severely truncated data better than conventional data preparation. This article is protected by copyright. All rights reserved.
Collapse
|
5
|
Evaluation of external stabilization of type II odontoid fractures in geriatric patients-An experimental study on a newly developed cadaveric trauma model. PLoS One 2021; 16:e0260414. [PMID: 34843595 PMCID: PMC8629171 DOI: 10.1371/journal.pone.0260414] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Accepted: 11/09/2021] [Indexed: 12/29/2022] Open
Abstract
Background Along with the growing geriatric population, the number of odontoid fractures is steadily increasing. However, the effectiveness of immobilizing geriatric odontoid fractures using a cervical collar has been questioned. The aim of the present study is to analyze the physiological and pathological motion in odontoid fractures and to assess limitation of motion in the cervical spine when applying a cervical collar. Methods Motion analysis was performed with wireless motion tracker on unfixed geriatric human cadavers. First, a new geriatric type II odontoid fracture model was developed. In this model, the type II odontoid fracture is operated via a transoral approach. The physiological and pathological flexion and lateral bending of the cervical spine resulting from this procedure was measured. The resulting motion after external stabilization using a cervical collar was analyzed. Results The new geriatric type II odontoid fracture model was successfully established using seven unfixed human cadavers. The pathological flexion of the cervical spine was significantly increased compared to the physiological flexion (p = 0.027). Furthermore, the flexion was significantly reduced when a cervical collar was applied. In case of flexion the mean remaining motion was significantly reduced (p = 0.0017) from 41° to 14°. For lateral bending the mean remaining motion was significantly reduced (p = 0.0137) from 48° to 18°. Conclusions In case of type II odontoid fracture, flexion and lateral bending of the cervical spine are increased due to spinal instability. Thus, if an odontoid fracture is suspected in geriatric patients, the application of a cervical collar should always be considered since external stabilization can significantly reduce flexion and lateral bending.
Collapse
|
6
|
Analysis of remaining motion using one innovative upper airway opening cervical collar and two traditional cervical collars. Sci Rep 2021; 11:20619. [PMID: 34663847 PMCID: PMC8523562 DOI: 10.1038/s41598-021-00194-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2021] [Accepted: 09/24/2021] [Indexed: 12/20/2022] Open
Abstract
The aim of this study was to compare the remaining motion of an immobilized cervical spine using an innovative cervical collar as well as two traditional cervical collars. The study was performed on eight fresh human cadavers. The cervical spine was immobilized with one innovative (Lubo Airway Collar) and two traditional cervical collars (Stifneck and Perfit ACE). The flexion and lateral bending of the cervical spine were measured using a wireless motion tracker (Xsens). With the Weinman Lubo Airway Collar attached, the mean remaining flexion was 20.0 ± 9.0°. The mean remaining flexion was lowest with the Laerdal Stifneck (13.1 ± 6.6°) or Ambu Perfit ACE (10.8 ± 5.8°) applied. Compared to that of the innovative Weinmann Lubo Airway Collar, the remaining cervical spine flexion was significantly decreased with the Ambu Perfit ACE. There was no significant difference in lateral bending between the three examined collars. The most effective immobilization of the cervical spine was achieved when traditional cervical collars were implemented. However, all tested cervical collars showed remaining motion of the cervical spine. Thus, alternative immobilization techniques should be considered.
Collapse
|
7
|
First experiences with intraoperative CT in navigated sacroiliac (SI) instrumentation: An analysis of 25 cases and comparison with conventional intraoperative 2D and 3D imaging. Injury 2021; 52:2730-2737. [PMID: 32113742 DOI: 10.1016/j.injury.2020.02.093] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2019] [Revised: 02/11/2020] [Accepted: 02/17/2020] [Indexed: 02/02/2023]
Abstract
BACKGROUND Intraoperative imaging is regularly used for intraoperative reduction control and evaluation of the implant position in trauma surgery. 2D imaging is limited, especially in complex anatomical regions such as the pelvis. The introduction of mobile 3D C-arms (CBCT: cone-beam computed tomography) has significantly improved intraoperative assessment. Nevertheless, there are still limitations regarding the field of view and metal artifacts. The purpose of this study was to evaluate the potential of intraoperative computed tomography (iCT) in surgical treatment of sacroiliac (SI) injuries. METHODS Twenty-five cases with injuries of the posterior pelvic ring involving the SI region that were surgically treated with navigated SI screws using the mobile iCT Airo (Brainlab, Munich, Germany) were analysed. Subsequently, the data were compared with historical control groups (CBCT with and without navigation; 2D fluoroscopy only). RESULTS The average score for subjective image quality achieved using the Likert scale is significantly higher for the iCT (4.48 ± 0.65) than for the CBCT (3.04 ± 0.69) with p = 0.00. The average duration of surgery using iCT was 189.32 ± 88.64 min, which was not significantly different from the control groups (p = 0.14 - 0.70). The average fluoroscopy time using iCT was 81.96 ± 97.34 s, which was significantly shorter than in all of the control groups (p = 0.00 - 0.03). The rate for postoperatively detected complications after using iCT was 0% (n = 0). Compared with the 2D-only control group (25%; n = 1), there is a significant difference (p = 0.01). The remaining two control groups showed no significant differences (p = 0.09 - 0.19). CONCLUSIONS The iCT provides excellent image quality that allows reliable assessment of fracture reduction and implant placement even in complex anatomical regions. The radiation exposure for the medical staff is reduced by decreasing the fluoroscopy time without significantly prolonging the surgical time. Overall, the possibility of intraoperative correction improves clinical outcome and patient treatment in the long term.
Collapse
|
8
|
Cervical Spine Immobilization in Patients With a Geriatric Facial Structure: The Influence of a Geriatric Mandible Structure on the Immobilization Quality Using a Cervical Collar. Geriatr Orthop Surg Rehabil 2021; 12:21514593211021824. [PMID: 34178417 PMCID: PMC8202247 DOI: 10.1177/21514593211021824] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2021] [Revised: 05/04/2021] [Accepted: 05/09/2021] [Indexed: 12/30/2022] Open
Abstract
Introduction: Demographic changes have resulted in an increase in injuries among geriatric patients. For these patients, a rigid cervical collar is crucial for immobilizing the cervical spine. However, evidence suggests that patients with a geriatric facial structure require a different means of immobilization than patients with an adult facial structure. This study aimed to analyze the remaining motion of the immobilized cervical spine based on facial structure. Materials and Methods: This study was performed on 8 fresh human cadavers. Facial structure was evaluated via ascertaining the mandibular angle by computer tomography. A mandibular angle below 130°, belongs to the adult facial structure group (n = 4) and a mandibular angle above 130°, belongs to the geriatric facial structure group (n = 4). The flexion and lateral bending of the immobilized cervical spine were analyzed in both groups using a wireless motion tracker system. Results: A flexion of up to 19.0° was measured in the adult facial structure group. The mean flexion in the adult vs. geriatric facial structure groups were 14.5° vs. 6.5° (ranges: 9.0-19.0 vs. 5.0-7.0°), respectively. Thus, cervical spine motion was (p = 0.0286) significantly more reduced in the adult facial structure group. No (p = 0.0571) significant difference was oberserved in the mean lateral bending of the adult facial structure group (14.5°) compared to the geriatric facial structure group (7.5°). Conclusion: Emergency medical service personnel should therefore follow current guidelines and recommendations and perform cervical spine immobilization with a cervical collar, including in patients with a geriatric facial structure.
Collapse
|
9
|
Fracture reduction and screw position after 3D-navigated and conventional fluoroscopy-assisted percutaneous management of acetabular fractures: a retrospective comparative study. Arch Orthop Trauma Surg 2021; 141:593-602. [PMID: 32519074 DOI: 10.1007/s00402-020-03502-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2019] [Accepted: 05/31/2020] [Indexed: 11/28/2022]
Abstract
BACKGROUND Navigational techniques in orthopaedic trauma surgery have developed over the last years leaving the question of really improving quality of treatment. Especially in marginal surgical indications, their benefit has to be evident. The aim of this study was to compare reduction and screw position following 3D-navigated and conventional percutaneous screw fixation of acetabular fractures. The study hypothesis postulated that better fracture reduction and better screw position are obtained with 3D navigation. MATERIALS AND METHODS Preoperative and postoperative CT scans of 37 acetabular fractures treated by percutaneous screw fixation (24 3D-navigated, 13 conventional) were evaluated. Differences in pre- and postoperative fracture gaps and steps were compared in all reconstructions as well as the screw position relative to the joint and the fracture. RESULTS The differences in fracture gaps and fracture steps with and without 3D navigation were not significantly different. Distance of the screw from the joint line, angle difference between screw and ideal angle relative to the fracture line, length of the possible corridor used and position of the screw thread did not show any significant differences. CONCLUSION Comparison of 3D-navigated and conventional percutaneous surgery of acetabular fractures on the basis of pre- and postoperative CTs revealed no significant differences in terms of fracture reduction and screw position.
Collapse
|
10
|
Vascular impulse technology versus elevation for the reduction of swelling of lower extremity joint fractures: results of a prospective randomized controlled study. Bone Joint J 2021; 103-B:746-754. [PMID: 33789481 PMCID: PMC9950846 DOI: 10.1302/0301-620x.103b4.bjj-2020-1260.r1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS Complex joint fractures of the lower extremity are often accompanied by soft-tissue swelling and are associated with prolonged hospitalization and soft-tissue complications. The aim of the study was to evaluate the effect of vascular impulse technology (VIT) on soft-tissue conditioning in comparison with conventional elevation. METHODS A total of 100 patients were included in this prospective, randomized, controlled monocentre study allocated to the three subgroups of dislocated ankle fracture (n = 40), pilon fracture (n = 20), and intra-articular calcaneal fracture (n = 40). Patients were randomized to the two study groups in a 1:1 ratio. The effectiveness of VIT (intervention) compared with elevation (control) was analyzed separately for the whole study population and for the three subgroups. The primary endpoint was the time from admission until operability (in days). RESULTS The mean length of time until operability was 8.2 days (SD 3.0) in the intervention group and 10.2 days (SD 3.7) in the control group across all three fractures groups combined (p = 0.004). An analysis of the subgroups revealed that a significant reduction in the time to operability was achieved in two of the three: with 8.6 days (SD 2.2) versus 10.6 days (SD 3.6) in ankle fractures (p = 0.043), 9.8 days (SD 4.1) versus 12.5 days (SD 5.1) in pilon fractures (p = 0.205), and 7.0 days (SD 2.6) versus 8.4 days (SD 1.5) in calcaneal fractures (p = 0.043). A lower length of stay (p = 0.007), a reduction in pain (ppreop = 0.05; pdischarge < 0.001) and need for narcotics (ppreop = 0.064; ppostop = 0.072), an increased reduction in swelling (p < 0.001), and a lower revision rate (p = 0.044) could also be seen, and a trend towards fewer complications (p = 0.216) became apparent. CONCLUSION Compared with elevation, VIT results in a significant reduction in the time to achieve operability in complex joint fractures of the lower limb. Cite this article: Bone Joint J 2021;103-B(4):746-754.
Collapse
|
11
|
Early Outcomes of Pelvic Trauma Patients - Complications, ICU Stay and Treatment Concepts in Two ATLS Compliant Trauma Centers: Germany and Qatar. ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA 2021; 88:418-422. [PMID: 34998444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
PURPOSE OF THE STUDY Pelvic trauma causes severe threats especially to polytraumatized patients. Not only it is in itself a possible cause for significant bleeding, but it also indicates a high risk for intra-abdominal injuries. The initial treatment of patients with pelvic trauma follows the ATLS principles of priority-oriented treatment. To examine the value of this highly standardized concept and to evaluate the effect of different patient collectives on early outcome parameters, two large collectives from Germany and Qatar were analyzed regarding injury parameters and early outcomes. MATERIAL AND METHODS Patients were recruited in Hamad General Hospital, Doha, Qatar (HGH) and BG Trauma Center Ludwigshafen, Germany (BG). All patients that were treated with a pelvic fracture between 2013 and 2016 were included in this retrospective analysis. Demographic parameters were collected as well as type of injury and the frequency of complication parameters as pneumonia, acute kidney failure, ARDS, sepsis and amount of blood transfusion. 1436 patients with pelvic fracture (645 from BG and 791 from HGH) were recruited. The mean age was 57.4 years in the BG and 33.6 years in the HGH group (p<0.000). The mean ISS was 17.81 in the BG and 15.88 in the HGH group (p=0.009). The mean pelvic AIS was 2.65 in the BG and 2.25 in the HGH group (p<0.000). RESULTS The mean frequency of complications was 9.3% in the BG and 9.9% in the HGH group (p=0.128). The mean frequency of ARDS was significantly higher in the BG group than in the HGH group (5.6% vs. 1.8%, p<0.000). The mean frequency of blood transfusion was significantly lower in the BG group than in the HGH group (28.8% vs. 39.2%, p<0.000). CONCLUSIONS Despite significant differences in the two collectives, this analysis shows comparable results regarding early outcome parameters in patients with pelvic injuries. In total, pelvic injuries are accompanied by a relatively high complication risk and need to be evaluated and treated according to priority-based algorithms. Key words: ATLS®, pelvic injury, complications, polytrauma.
Collapse
|
12
|
Evaluation of image quality and assessability of a new flat‐panel 3D C‐arm compared to mobile and fixed computed tomography in posterior spinal fixation. Int J Med Robot 2020; 17:e2181. [DOI: 10.1002/rcs.2181] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2020] [Revised: 09/25/2020] [Accepted: 10/07/2020] [Indexed: 11/06/2022]
|
13
|
Patterns, management, and outcomes of traumatic pelvic fracture: insights from a multicenter study. J Orthop Surg Res 2020; 15:249. [PMID: 32646448 PMCID: PMC7344030 DOI: 10.1186/s13018-020-01772-w] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2020] [Accepted: 06/30/2020] [Indexed: 01/07/2023] Open
Abstract
Background Traumatic pelvic fracture (TPF) is a significant injury that results from high energy impact and has a high morbidity and mortality. Purpose We aimed to describe the epidemiology, incidence, patterns, management, and outcomes of TPF in multinational level 1 trauma centers. Methods We conducted a retrospective analysis of all patients with TPF between 2010 and 2016 at two trauma centers in Qatar and Germany. Results A total of 2112 patients presented with traumatic pelvic injuries, of which 1814 (85.9%) sustained TPF, males dominated (76.5%) with a mean age of 41 ± 21 years. In unstable pelvic fracture, the frequent mechanism of injury was motor vehicle crash (41%) followed by falls (35%) and pedestrian hit by vehicle (24%). Apart from both extremities, the chest (37.3%) was the most commonly associated injured region. The mean injury severity score (ISS) of 16.5 ± 13.3. Hemodynamic instability was observed in 44%. Blood transfusion was needed in one third while massive transfusion and intensive care admission were required in a tenth and a quarter of cases, respectively. Tile classification was possible in 1228 patients (type A in 60%, B in 30%, and C in 10%). Patients with type C fractures had higher rates of associated injuries, higher ISS, greater pelvis abbreviated injury score (AIS), massive transfusion protocol activation, prolonged hospital stay, complications, and mortality (p value < 0.001). Two-thirds of patients were managed conservatively while a third needed surgical fixation. The median length of hospital and intensive care stays were 15 and 5 days, respectively. The overall mortality rate was 4.7% (86 patients). Conclusion TPF is a common injury among polytrauma patients. It needs a careful, systematic management approach to address the associated complexities and the polytrauma nature.
Collapse
|
14
|
Minimally invasive surgical treatment of minimally displaced acetabular fractures does not improve pain, mobility or quality of life compared to conservative treatment: a matched-pair analysis of 50 patients. J Orthop Surg Res 2020; 15:115. [PMID: 32293501 PMCID: PMC7092457 DOI: 10.1186/s13018-020-01611-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/22/2019] [Accepted: 02/17/2020] [Indexed: 11/22/2022] Open
Abstract
Background Currently available procedures for the treatment of minimally displaced acetabular fractures include conservative treatment and minimally invasive percutaneous screw fixation. Screw fixation of acetabular fractures allows patients’ early full-weight bearing due to improved biomechanic stability. Can the range of motion, pain and mobility and quality of life in patients with acetabular fractures be improved by minimally invasive screw fixation, compared to conservative treatment in the long term? Methods Patients treated for a minimally displaced acetabular fracture, either conservatively or by closed reduction percutaneous screw fixation, in the period from 2001 to 2013 were included in this retrospective study. Minimal displacement was considered to be less than 5 mm. As well as the collection and analysis of baseline data, Harris Hip Score, Merle d’Aubigné score and Short Form 12 (SF-12) questionnaire data were recorded in the context of a clinical study. To better account for confounding factors, patients of each group were matched. The matched-pair criteria included age, BMI, Letournel fracture classification and the presence of associated injuries. Results Twenty-five patients from each group were matched. On the Harris Hip Score, conservatively treated patients obtained 96 points (52–100, SD 17) vs. 89 points (45–100, SD 17, p = 0.624). On the Merle d’Aubigné score, conservatively treated patients obtained 17 points (10–18, SD 2) vs. 17 points (11–18, SD 2, p = 0.342). Patients with acetabular fractures treated by minimally invasive screw fixation did not result in improved quality of life, measured by SF-12 questionnaire, compared to conservatively treated patients (PCS 47, SD 9 vs. 44, SD 10; p = 0.294 and MCS 51, SD 7 vs. 53, SD 7; p = 0.795). Conclusions The clinical results of the two groups revealed no statistically significant differences. From the data, it cannot be deduced that minimally invasive surgical therapy is superior to conservative treatment of minimally displaced acetabular fractures. Prospective randomised studies are recommended to allow reliable evaluation of both treatment options. Trial registration Retrospectively registered
Collapse
|
15
|
Diagnostic accuracy of intraoperative CT-imaging in complex articular fractures - a cadaveric study. Sci Rep 2020; 10:4530. [PMID: 32161337 PMCID: PMC7066240 DOI: 10.1038/s41598-020-61267-w] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2018] [Accepted: 02/25/2020] [Indexed: 11/09/2022] Open
Abstract
Anatomic reconstruction of articular fractures is one of the critical factors in later achieving good functional outcome. Intraoperative 3D imaging has been shown to offer better evaluation and therefore can significantly improve the results. The purpose of this study was to assess the difference between intraoperative three-dimensional fluoroscopy (3D) and intraoperative computed tomography (iCT) imaging regarding fracture reduction, implant placement and articular impressions in a distal humeral fracture model. AO type 13-B2 fracture pattern were created in upper extremity cadaver specimens. Articular step-offs, intra-articular screw placement and intraarticular impressions of different degrees of severity were created. All specimens had imaging performed. For each articular pattern 3D fluoroscopy in standard (3Ds) and high quality (3Dh) were performed (Arcadis Orbic, Siemens, Germany) as well as an intraoperative CT scan (iCT, Airo, Brainlab, Germany). Three observers evaluated all imaging studies regarding subjective and objective parameters. iCT is more precise than 3D fluoroscopic imaging for detection of articular impressions. Articular step-offs and intraarticular screw placement are similar for iCT and 3D. Subjective imaging quality is the highest for iCT and lowest for 3Ds. Intraoperative CT may be particularly useful in assessing articular impressions and providing a good subjective image quality for the surgeon.
Collapse
|
16
|
Validation of radiological reduction criteria with intraoperative cone beam CT in unstable syndesmotic injuries. Eur J Trauma Emerg Surg 2020; 47:897-903. [PMID: 32100086 PMCID: PMC8321975 DOI: 10.1007/s00068-020-01299-z] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2019] [Accepted: 01/03/2020] [Indexed: 12/11/2022]
Abstract
Purpose Acute unstable syndesmotic lesions are regularly treated with closed or open reduction and fixation with either a positioning screw or tight rope. Conventional fluoroscopy is limited to identify a malreduction of the ankle mortise. The aim of the study was to validate the reduction criteria of intraoperative cone beam CT in unstable syndesmotic injuries by analyzing the clinical outcome. Methods Acute unstable syndesmotic injuries were treated with a positioning screw fixation, and the reduction in the ankle mortise was evaluated with intraoperative cone beam CT. The patients were grouped postoperatively according to the radiological reduction criteria in the intraoperative 3D images. The reduction criteria were unknown to the surgeons. Malreduction was assumed if one or more reduction criteria were not fulfilled. Results Seventy-three of the 127 patients could be included in the study (follow-up rate 57.5%). For 41 patients (56.2%), a radiological optimal reduction was achieved (Group 1), and in 32 patients (43.8%) a radiological adverse reduction was found (Group 2). Group 1 scored significantly higher in the Olerud/Molander score (92.44 ± 10.73 vs. 65.47 ± 28.77) (p = 0.003), revealed a significantly higher range of motion (ROM) (53.44 vs. 24.17°) (p = 0.001) and a significantly reduced Kellgren/Lawrence osteoarthritis score (1.24 vs. 1.79) (p = 0.029). The linear regression analysis revealed a correlation for the two groups with the values scored in the Olerud/Molander score (p < 0.01). Conclusion The reduction criteria in intraoperative cone beam CT applied to unstable syndesmotic injuries could be validated. Patients with an anatomic reduced acute unstable syndesmotic injury according to the criteria have a significantly better clinical outcome.
Collapse
|
17
|
[Reconstruction of a fracture of the posterior acetabular wall with Pipkin fracture and lesion of the sciatic nerve after dorsal hip dislocation]. Unfallchirurg 2020; 123:413-418. [PMID: 32060596 DOI: 10.1007/s00113-020-00783-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
A 50-year-old male suffered a crash landing while paragliding and sustained a posterior dislocation of the hip with a Pipkin fracture type 4 (fracture of the posterior acetabular wall and Pipkin fracture type 2) and a lesion of the sciatic nerve. After primary treatment in an external hospital, the patient was transferred to this hospital 4 days following the trauma. An operative stabilization of the acetabular fracture and the Pipkin fracture was performed using a trochanter flip osteotomy. Despite a large central defect of the femoral head it was decided to attempt a reconstruction. Following fixation of the Pipkin fragment an autologous bone graft harvested from the intertrochanteric region was used to fill the defect. Subsequently, a collagen matrix was applied onto the filled defect and a perineural adaptation of the sciatic nerve was performed.
Collapse
|
18
|
Influence of reduction quality on functional outcome and quality of life in treatment of tibial plafond fractures: a retrospective cohort study. BMC Musculoskelet Disord 2019; 20:534. [PMID: 31722696 PMCID: PMC6854804 DOI: 10.1186/s12891-019-2932-2] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Accepted: 11/01/2019] [Indexed: 11/21/2022] Open
Abstract
Background The aim of the study was to evaluate the impact of reduction quality, using intraoperative 3D imaging, on quality of life and functional outcome in the operative treatment of tibial plafond fractures. Methods A group of patients with tibial plafond fractures was re-examined. The operative treatment was performed between September 2001 and October 2011. The follow-up examination was at least 2 years after the final surgical procedure. Final reduction result was assessed intraoperatively using a mobile 3D C-arm. A categorization with regard to descriptive parameters as well as type and size of joint surface irregularities was performed. Follow-up results were evaluated using: Olerud and Molander (O & M) score, Short-Form-36 (SF-36) score, movement deficit, Kellgren and Lawrence grade of osteoarthritis, and pain intensity. Results 34 patients with operatively treated tibial plafond fracture could be re-examined. Reduction quality had the greatest influence on functional result measured by the O & M score (p = 0.001) and the PCS domain of the SF-36 score (p = 0.018). Significant differences with regard to O & M score (p = 0.000), SF-36 score (p = 0.001 to p = 0.02; without MCS domain), movement deficit (p = 0.001), grade of osteoarthritis (p = 0.005) and pain (p = 0.001) could be verified under consideration of the reduction quality. The group with the anatomically more accurate reduction also showed a better result for clinical follow-up and quality of life. Furthermore, it is not the type of joint surface irregularity that is always decisive, but rather the size. Conclusions Despite other relevant factors, it appears that reduction quality –which can be analyzed with intraoperative 3D imaging– plays the most important role in postoperative quality of life and functional outcome. Corrections should therefore be performed on joint surface irregularities with a size above 2 mm.
Collapse
|
19
|
Comparison of three different reduction methods of the ankle mortise in unstable syndesmotic injuries. Sci Rep 2019; 9:15445. [PMID: 31659196 PMCID: PMC6817893 DOI: 10.1038/s41598-019-51988-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2018] [Accepted: 10/10/2019] [Indexed: 12/02/2022] Open
Abstract
In order to achieve a clinically satisfying result and to prevent posttraumatic osteoarthritis in the treatment of unstable syndesmotic injuries, anatomically correct reduction is crucial. The objective of the study was to investigate three different reduction methods of the ankle mortise in unstable syndesmotic injuries. In a specimen model with 38 uninjured fresh-frozen lower legs, a complete syndesmotic dissection was performed. The ankle mortise was reduced with either a collinear reduction clamp, a conventional reduction forceps or manually with crossing K-wires. The reduction clamps and the K-wires were placed in a 0°-angle to the leg axis. The clamps were positioned on the posterolateral ridge of the fibula 20 mm proximal to the ankle joint line. A cone beam computed tomography was performed after dissection and after each reduction. Tibio-fibular distances and angles were determined. Despite significant differences in terms of overcompression (0.09–0.33 mm; p = 0.000–0.063) and the slight external rotation (0.29–0.47°; p = 0.014–0.07), the results show a satisfying reduction of the ankle mortise. There were no considerable differences between the reduction methods. It can therefore be concluded that the ankle mortise can be reduced with any of the methods used, but that the positioning and the contact pressure must be considered.
Collapse
|
20
|
Computer-assisted intra-operative verification of surgical outcome for the treatment of syndesmotic injuries through contralateral side comparison. Int J Comput Assist Radiol Surg 2019; 14:2211-2220. [PMID: 31392672 DOI: 10.1007/s11548-019-02043-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2019] [Accepted: 07/26/2019] [Indexed: 11/29/2022]
Abstract
PURPOSE Fracture reduction and fixation of syndesmotic injuries is a common procedure in trauma surgery. An intra-operative evaluation of the surgical outcome is challenging due to high inter-individual anatomical variation. A comparison to the contralateral uninjured ankle would be highly beneficial but would also incur additional radiation and time consumption. In this work, we pioneer automatic contralateral side comparison while avoiding an additional 3D scan. METHODS We reconstruct an accurate 3D surface of the uninjured ankle joint from three low-dose 2D fluoroscopic projections. Through CNN complemented 3D shape model segmentation, we create a reference model of the injured ankle while addressing the issues of metal artifacts and initialization. Following 2D-3D multiple bone reconstruction, a final reference contour can be created and matched to the uninjured ankle for contralateral side comparison without any user interaction. RESULTS The accuracy and robustness of individual workflow steps were assessed using 81 C-arm datasets, with 2D and 3D images available for injured and uninjured ankles. Furthermore, the entire workflow was tested on eleven clinical cases. These experiments showed an overall average Hausdorff distance of [Formula: see text] mm measured at clinical evaluation level. CONCLUSION Reference contours of the contralateral side reconstructed from three projection images can assist surgeons in optimizing reduction results, reducing the duration of radiation exposure and potentially improving postoperative outcomes in the long term.
Collapse
|
21
|
Intraoperative 3D imaging leads to substantial revision rate in management of tibial plateau fractures in 559 cases. J Orthop Surg Res 2019; 14:236. [PMID: 31340818 PMCID: PMC6657091 DOI: 10.1186/s13018-019-1286-7] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/31/2019] [Accepted: 07/19/2019] [Indexed: 11/10/2022] Open
Abstract
Introduction The aim of this study was to evaluate the intraoperative revision rate and reasons for revision following 3D imaging in the management of dislocated articular tibial plateau fractures based on a large patient sample. Methods This retrospective cohort study included all patients who underwent open reduction and internal fixation due type B or C tibial plateau fracture according to the AO/OTA classification between August 2001 and December 2017 using intraoperative cone beam CT (3D imaging) for the analysis of fracture reduction and implant placement. The findings of the 3D scan were categorized regarding the amount and type of revision. Furthermore, demographic data was examined. Results Five hundred and fifty-nine consecutive fractures were included in the study. Evaluation of the image data records revealed an intraoperative revision due to the usage of 3D imaging in 148 out of 559 cases (26.5%). The most common reasons for an intraoperative revision were insufficient fracture reduction (114 cases) and screw length (21 cases). Conclusion This study reveals indications for a limited analysis of fracture reduction and implant placement during the operative treatment of dislocated articular tibial plateau fractures using conventional fluoroscopy. In view of the high revision rate during open reduction and internal fixation of tibial plateau fractures due to 3D imaging the usage of intraoperative cone beam, CT may be considered. If this is not possible, a postoperative computed tomography may therefore be reasonable.
Collapse
|
22
|
Influence of ankle joint position on angles and distances of the ankle mortise using intraoperative cone beam CT: A cadaveric study. PLoS One 2019; 14:e0217737. [PMID: 31150469 PMCID: PMC6544278 DOI: 10.1371/journal.pone.0217737] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2017] [Accepted: 05/18/2019] [Indexed: 12/25/2022] Open
Abstract
BACKGROUND The precise anatomical reduction of the ankle mortise is crucial for the clinical outcome in unstable syndesmotic injuries. Intraoperative cone beam computed tomography (CT), in addition to two-dimensional fluoroscopy, provides detailed information about the reduction and implant placement. The aim of this study was to analyze the influence of the joint position on the fibula position in the incisural notch and to determine the inter- and intraindividual anatomical differences in the intact ankle joints. METHODS A total of 20 fresh-frozen lower legs disarticulated in the knee joint of 10 individuals were included. The measurements were performed using a cone beam CT. The distances and angles were measured in the standard imaging planes. The mean values of distances and angles were compared during the different joint positions: 10° dorsiflexion, 0° neutral position and 20° plantar flexion. RESULTS The influence of the joint position was on average as follows: The anterior tibiofibular distance was 3.68 mm in 10° dorsiflexion, 3.66 mm (0° neutral position) and 3.59 mm (20° plantar flexion). The posterior tibiofibular distance measured 7.82mm, 7.76mm and 7.82mm. The rotation of the fibula measured ten millimeters proximal the joint line was 1.2°, 1.3° and 1.05°. The fibular rotation determined 4mm was 9.3°, 9.4° and 9.4°. On average, the following intraindividual variations were observed: superior tibiotalar clear space of 0.27mm and 0.15mm medial; and anterior tibiofibular distance of 0.42mm, 0.38mm posterior and 0.24mm in the incisural notch. The proximal angle of the fibular rotation was 0.2° and distal 0.4°. The interindividual variations of the angles and distances exceeded the intraindividual values partly by 3 to 4 fold. CONCLUSIONS Within the scope of this study neither the tibiofibular distance, nor the tibiofibular angle changed significantly through the different joint positions. The intraindividual differences were little while the interindividual variations of the parameters were distinctive.
Collapse
|
23
|
First experiences with the Airo mobile intraoperative CT scanner in acetabular surgery-An analysis of 10 cases. Int J Med Robot 2019; 15:e1986. [PMID: 30710466 DOI: 10.1002/rcs.1986] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2018] [Revised: 01/15/2019] [Accepted: 01/25/2019] [Indexed: 11/11/2022]
Abstract
BACKGROUND Being a proven method in trauma and spine surgery, intraoperative 3D imaging (CBCT) has intrinsic deficits in difficult anatomy and with artifacts because of metal implants. The purpose of this study was to evaluate the use of intraoperative computed tomography (iCT) in acetabular surgery. METHODS Ten cases of acetabular fractures that were operated with intraoperative use of the mobile CT scanner Brainlab Airo were analyzed. Data were compared with a historical group of 17 patients. RESULTS Additional fluoroscopy time was 24.2 seconds (6-91), which was significantly lower than in the control group where it was 211.4 seconds (77-446; P < 0.000). Operation time did not differ significantly (iCT group 196.8 min [122-288], control group 240.8 min [71-411], P = 0.234). CONCLUSION iCT provides images of a reliable high quality and assessability. Radiation exposure to the staff is reduced while surgery time is not altered significantly. Quality of intraoperative imaging and thus patient care can substantially improve patient outcome.
Collapse
|
24
|
Influence of intraoperative conventional fluoroscopy versus cone beam CT on long-term clinical outcome in isolated displaced talar fractures. J Orthop Surg Res 2019; 14:8. [PMID: 30621768 PMCID: PMC6323861 DOI: 10.1186/s13018-018-1043-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Accepted: 12/18/2018] [Indexed: 11/10/2022] Open
Abstract
INTRODUCTION The objective of the study was to compare the radiologic and clinical outcome of patients with an isolated displaced talus fracture treated intra-operatively with either conventional fluoroscopy or additional cone beam computed tomography (CT). METHODS Conventional intraoperative fluoroscopy was performed in group 1 and cone beam CT was added in group 2. Clinical outcome was assessed using the Foot Function Index (FFI), American Foot and Ankle Society (AOFAS) Ankle-Hindfoot Scale, and the Short-Form 12 (SF-12) survey. In addition, the Kellgren-Lawrence score using X-rays was determined. RESULTS Overall, 24 cases were examined (group 1: 8 cases; group 2: 16 cases), with a mean follow up of 6.66 years. The FFI (group 1: 28.85 ± 22.78; group 2: 14.96 ± 15.11 points; p = 0.768), the AOFAS (group 1: 69.00 ± 24.71; group 2: 78.79 ± 17.07 points; p = 0.438), and the physical and mental component of the SF-12 (group 1: 44.79 ± 12.55; group 2: 47.63 ± 10.69 points; p = 0.136) (group 1: 46.19 ± 9.72; group 2: 53.57 ± 8.51; p = 0.242) did not differ significantly. Osteoarthritis of the talonavicular, subtalar, and ankle joints assessed using the Kellgren-Lawrence score appeared to be minor in the cone beam CT group but did not show significant differences (p = 0.309; p = 0.663; p = 0.082 respectively). DISCUSSION Intraoperative cone beam CT in addition to conventional fluoroscopy might be beneficial in the operative treatment of talar fractures but a statistical significance could not be demonstrated.
Collapse
|
25
|
Intraoperative Imaging in Pelvic Surgery. ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE 2018; 157:367-377. [DOI: 10.1055/a-0732-5986] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
AbstractPelvic fractures may range from highly severe, life-threatening injuries to less acute clinical entities. There are several sub-entities that are summed up as pelvic injuries. Anatomically, there are fractures of the anterior or posterior pelvic ring. Apart from these, there are fractures of the acetabulum that make up about one fifth of all pelvic injuries. The indication for surgical treatment of pelvic ring injuries depends on the type of injury, involvement of anterior and/or posterior elements of the pelvic ring, demands and the general condition of the patient. In acetabular fractures, indications depend on the dislocation of the fracture and of course also the needs of the patient and his general condition. An intraarticular step-off of more than 2 mm is usually considered as an indication for open reduction and osteosynthesis. Usually in all these injuries, a preoperative CT scan is mandatory to allow precise planning of the operative approach and technique. Intraoperatively, the surgeon should be familiar with the acquisition of the 2D standard views, including 2D imaging of the pelvic ring and the acetabulum. These consist of the anteroposterior view for both pelvic ring and acetabular osteosyntheses. For further assessment of pelvic ring treatments, inlet and outlet views are achievable by angulating the C-arm cranially and caudally. To assess aspects of the anterior and posterior column of the acetabulum, iliac oblique views are used. Here, the C-arm is rotated laterally. As evaluation of 2D views can be limited due to anatomy and superposing structures, intraoperative 3D imaging has become common in the last decade. Special C-arms allow the automatic acquisition of large numbers of projections and create CT-like views of the central volume. Although this method has significantly widened the possibilities of intraoperative imaging, some issues remain. Depending on the amount of implants placed in the imaging field, assessment can be seriously impaired due to artefacts caused by the implants. Intraoperative CT imaging promises enhanced image quality for artefacts and allows a considerably larger field of view. The use of radiation-free navigation facilitates implant placement in minimally invasive procedures like screw placement in the sacroiliacal joint or the acetabulum by visualisation of instruments and implants in a pre- or intraoperative 3D data set.
Collapse
|
26
|
Injury patterns in professional motorbike racing: a retrospective analysis of 728 falls. J Sports Med Phys Fitness 2018; 59:817-821. [PMID: 30293412 DOI: 10.23736/s0022-4707.18.09056-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND In professional motorbike racing falls with high velocities are common. Nonetheless, severe injuries or deaths are rare when compared to regular road traffic. METHODS In this study, falls in all courses of the largest German race series IDM*Superbike between 2007 and 2013 were analyzed regarding injury patterns and hospital admissions. All races were accompanied by a medical team, including at least one physician who assessed every patient. RESULTS A total of 728 falls were included. A specific fall mechanism could be determined in 45.5% of the cases. 40.5% were admitted to a trauma center for further diagnostics. A definitive diagnosis was found in 45.4%. In most cases (29.9%) the injury pattern was a fracture of the extremities. In collisions a significantly higher odds ratio of 2.52 (P=0.0001) and in undetermined falls a significantly lower odds ratio of 0.47 (P<0.0001) was observed. CONCLUSIONS Fall patterns in professional motorbike racing do not significantly correlate with the severity of the injury. Thus, as in regular patient evaluation, each patient has to be examined thoroughly to avoid misinterpretation.
Collapse
|
27
|
Abstract
The reconstruction of anatomical joint surfaces, limb alignment and rotational orientation are crucial in the treatment of fractures in terms of preservation of function and range of motion. To assess reduction and implant position intra-operatively, mobile C-arms are mandatory to immediately and continuously control these parameters.Usually, these devices are operated by OR staff or radiology technicians and assessed by the surgeon who is performing the procedure. Moreover, due to special objectives in the intra-operative setting, the situation cannot be compared with standard radiological image acquisition. Thus, surgeons need to be trained and educated to ensure correct technical conduct and interpretation of radiographs.It is essential to know the standard views of the joints and long bones and how to position the patient and C-arm in order to acquire these views. Additionally, the operating field must remain sterile, and the radiation exposure of the patient and staff must be kept as low as possible.In some situations, especially when reconstructing complex joint fractures or spinal injuries, complete evaluation of critical aspects of the surgical results is limited in two-dimensional views and fluoroscopy. Intra-operative three-dimensional imaging using special C-arms offers a valuable opportunity to improve intra-operative assessment and thus patient outcome.In this article, common fracture situations in trauma surgery as well as special circumstances that the surgeon may encounter are addressed. Cite this article: EFORT Open Rev 2018;3:541-549. DOI: 10.1302/2058-5241.3.170074.
Collapse
|
28
|
Virtual guidance versus virtual implant planning system in the treatment of distal radius fractures. Int J Med Robot 2018; 14:e1945. [PMID: 30084164 DOI: 10.1002/rcs.1945] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2018] [Revised: 05/18/2018] [Accepted: 07/04/2018] [Indexed: 11/05/2022]
Abstract
BACKGROUND A virtual guidance framework is used to assist the conventional method of virtual implant planning system (VIPS). The study null hypothesis was that its screw placement accuracy is equal to that of conventional VIPS. METHODS In 34 distal radius sawbone models, 3D implant planning was performed. A camera attached to the surgical drill was used to support screw positioning. Differences of angles/tip distances between planned and placed screws were identified in intraoperative cone beam Computer tomography (CT) and compared with already existing data from 22 patients treated by conventional VIPS. RESULTS The virtual guidance group showed tip distances of 1.02 ± 0.56 mm, azimuth of 3.69° ± 4.34°, and inclination of 1.75° ± 1.37°, whereas the VIPS group showed tip distances of 2.23 ± 0.99 mm (P < 0.001), azimuth of 23.17° ± 33.50° (P < 0.001), and inclination angle of 4.18° ± 6.29° (P = 0.001). CONCLUSIONS The results reveal that using a guidance framework leads to a higher accuracy in screw placement compared with the conventional VIPS itself.
Collapse
|
29
|
Intraoperative assessment of reduction and implant placement in acetabular fractures-limitations of 3D-imaging compared to computed tomography. J Orthop Surg Res 2018; 13:78. [PMID: 29636062 PMCID: PMC5894195 DOI: 10.1186/s13018-018-0780-7] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2018] [Accepted: 03/23/2018] [Indexed: 01/24/2023] Open
Abstract
Background In acetabular fractures, the assessment of reduction and implant placement has limitations in conventional 2D intraoperative imaging. 3D imaging offers the opportunity to acquire CT-like images and thus to improve the results. However, clinical experience shows that even 3D imaging has limitations, especially regarding artifacts when implants are placed. The purpose of this study was to assess the difference between intraoperative 3D imaging and postoperative CT regarding reduction and implant placement. Methods Twenty consecutive cases of acetabular fractures were selected with a complete set of intraoperative 3D imaging and postoperative CT data. The largest detectable step and the largest detectable gap were measured in all three standard planes. These values were compared between the 3D data sets and CT data sets. Additionally, possible correlations between the possible confounders age and BMI and the difference between 3D and CT values were tested. Results The mean difference of largest visible step between the 3D imaging and CT scan was 2.0 ± 1.8 mm (0.0–5.8, p = 0.02) in the axial, 1.3 ± 1.4 mm (0.0–3.7, p = 0.15) in the sagittal and 1.9 ± 2.4 mm (0.0–7.4, p = 0.22) in the coronal views. The mean difference of largest visible gap between the 3D imaging and CT scan was 3.1 ± 3.6 mm (0.0–14.1, p = 0.03) in the axial, 4.6 ± 2.7 mm (1.2–8.7, p = 0.001) in the sagittal and 3.5 ± 4.0 mm (0.0–15.4, p = 0.06) in the coronal views. A positive correlation between the age and the difference in gap measurements in the sagittal view was shown (rho = 0.556, p = 0.011). Conclusions Intraoperative 3D imaging is a valuable adjunct in assessing reduction and implant placement in acetabular fractures but has limitations due to artifacts caused by implant material. This can lead to missed malreduction and impairment of clinical outcome, so postoperative CT should be considered in these cases.
Collapse
|
30
|
Wire Placement in the Sustentaculum Tali Using a 2D Projection-Based Software Application for Mobile C-Arms: Cadaveric Study. Foot Ankle Int 2018; 39:485-492. [PMID: 29347832 DOI: 10.1177/1071100717746618] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND Indirect screw fixation of the sustentaculum tali in the lateral-medial direction can be challenging due to the complex calcaneal anatomy. A novel 2-dimensional (2D) projection-based software application detects Kirschner wires (K-wires) and visualizes their intended direction as a colored trajectory. The aim of this prospectively randomized cadaver study was to investigate whether the software would facilitate the indirect K-wire placement in the sustentaculum tali. METHODS In 20 cadaver foot specimens, K-wires were placed indirectly in the sustentaculum tali by an experienced and an inexperienced surgeon, with and without using the application. Number of placement attempts, duration of procedure, fluoroscopy time, and number of individual fluoroscopy images were recorded. Each wire's position was analyzed in a 3-dimensional (3D) C-arm scan by an experienced blinded investigator. RESULTS Use of the software by the inexperienced surgeon significantly reduced the number of placement attempts from 3.2 to 1.2 ( P = .006). The application also reduced operating time, from 273 s to 199 s ( P = .15), and fluoroscopy time, from 41 s to 29 s ( P = .15). Using the software, the experienced surgeon had a longer operating time (139 s to 183 s; P = .30), longer fluoroscopy time (5.6 s to 9.2 s; P = .17), and more individual fluoroscopy images (11.6 to 14.8; P = .30). Wire position did not show significant differences in both cases. CONCLUSION During indirect K-wire placement in the sustentaculum tali, the software appeared to be a useful tool for the inexperienced surgeon. In our chosen study setting, the experienced surgeon did not benefit from the software. CLINICAL RELEVANCE Possible indications for the software would be fractures of the proximal femur, sacrum, sacroiliac instabilities, vertebral bodies, scaphoid, Lisfranc joint, talus and calcaneus.
Collapse
|
31
|
Long-term results after non-operative and operative treatment of radial neck fractures in adults. J Orthop Surg Res 2018; 13:28. [PMID: 29394909 PMCID: PMC5797341 DOI: 10.1186/s13018-018-0731-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/03/2017] [Accepted: 01/23/2018] [Indexed: 11/10/2022] Open
Abstract
Background The aim of this study is to determine the functional long-term outcome after non-operative and operative treatment of radial neck fractures in adults. Methods Thirty-four consecutive patients with a mean age of 46.4 (18.0 to 63.0) years with a fracture of the radial neck who were treated between 2000 and 2014 were examined regarding the clinical and radiological outcome. Twenty patients were treated non-operatively, and 14 patients underwent surgery. Results After a mean follow-up of 5.7 (2.0 to 15.7) years, the clinical scores showed good results in both groups. The Disabilities of Arm, Shoulder and Hand score was 16.1 (0 to 71.6) in the non-operative group and 8.8 (0 to 50.8) in the operative group, respectively. The Mayo Elbow Performance Score was 80.0 (30 to 95) in the non-operative group and 82.5 (35 to 95) in the non-operative group, respectively. The initial angle of the radial head towards the shaft (RHSA) was significantly higher in the operative group in the anterior-posterior plane (12.8° [2 to 23] vs. 26.3° [1 to 90], p = 0.015). In the follow-up radiographs, the RHSA was significantly lower in the operative group (15.1° [3 to 30] vs. 10.9° [3 to 18], p = 0.043). Five patients developed 7 complications in the non-operative group, and 7 patients developed 12 complications in the operative group. Revision rates were higher in the operative groups as 1 patient received radial head resection in the non-operative (5%) group while 7 patients in the operative group (50%) needed revision surgery. Conclusion A good functional long-term outcome can be expected after operative and non-operative treatment of radial neck fractures in adults. If needed due to major displacement, open reduction is associated with a higher risk of complications and the need for revision surgery but can achieve similar clinical results. Trial registration DRKS DRKS00012836 (retrospectively registered)
Collapse
|
32
|
2D projection-based software application for mobile C-arms optimises wire placement in the proximal femur - An experimental study. Injury 2017; 48:2068-2073. [PMID: 28774707 DOI: 10.1016/j.injury.2017.07.022] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/15/2017] [Revised: 05/18/2017] [Accepted: 07/17/2017] [Indexed: 02/02/2023]
Abstract
PURPOSE A new software application can be used without fixed reference markers or a registration process in wire placement. The aim was to compare placement of Kirschner wires (K-wires) into the proximal femur with the software application versus the conventional method without guiding. As study hypothesis, we assumed less placement attempts, shorter procedure time and shorter fluoroscopy time using the software. The same precision inside a proximal femur bone model using the software application was premised. METHODS The software detects a K-wire within the 2D fluoroscopic image. By evaluating its direction and tip location, it superimposes a trajectory on the image, visualizing the intended direction of the K-wire. The K-wire was positioned in 20 artificial bones with the use of software by one surgeon; 20 bones served as conventional controls. A brass thumb tack was placed into the femoral head and its tip targeted with the wire. Number of placement attempts, duration of the procedure, duration of fluoroscopy time and distance to the target in a postoperative 3D scan were recorded. RESULTS Compared with the conventional method, use of the application showed fewer attempts for optimal wire placement (p=0.026), shorter duration of surgery (p=0.004), shorter fluoroscopy time (p=0.024) and higher precision (p=0.018). Final wire position was achieved in the first attempt in 17 out of 20 cases with the software and in 9 out of 20 cases with the conventional method. CONCLUSIONS The study hypothesis was confirmed. The new application optimised the process of K-wire placement in the proximal femur in an artificial bone model while also improving precision. Benefits lie especially in the reduction of placement attempts and reduction of fluoroscopy time under the aspect of radiation protection. The software runs on a conventional image intensifier and can therefore be easily integrated into the daily surgical routine.
Collapse
|
33
|
Unstable simple elbow dislocations: medium-term results after non-surgical and surgical treatment. Knee Surg Sports Traumatol Arthrosc 2017; 25:2271-2279. [PMID: 27043345 DOI: 10.1007/s00167-016-4100-7] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/08/2015] [Accepted: 03/22/2016] [Indexed: 10/22/2022]
Abstract
PURPOSE Determination of the appropriate treatment of unstable simple elbow dislocations is difficult and a topic of ongoing discussion. The aim of this study was to analyse the outcome and complications after surgery and conservative treatment, with special focus on post-traumatic joint laxity. METHODS In this retrospective study, 118 consecutive patients with simple elbow dislocations underwent stability testing by fluoroscopy after joint reduction and were assigned to groups 1 (slight), 2 (moderate) or 3 (gross) depending on post-traumatic joint laxity. All patients of group 1 underwent conservative treatment, and of group 3 primary ligament repair. In patients with moderate elbow laxity, the treatment was decided individually. All patients underwent a similar functional rehabilitation programme during treatment. Clinical outcome was determined after an average of 3.4 ± 1.5 years using the Mayo Elbow Performance Score (MEPS), and treatment-associated complications and revisions were recorded. RESULTS Forty-nine patients (41.5 %) were assigned to group 1, 41 patients (34.7 %) to group 2 and 28 patients (23.7 %) to group 3. In group 2, 22 patients underwent ligament repair, while 19 patients were treated conservatively. On average, an excellent MEPS was achieved in group 1 after conservative treatment (MEPS 95.8 ± 9.0), similar to results after ligament repair of grossly unstable elbows in group 3 (91.6 ± 11.7). Interestingly, in group 2 conservative treatment was associated with a slightly lower MEPS (90.0 vs. 95.7), and significantly fewer patients achieved an excellent MEPS (81.8 vs. 52.6 %, p = 0.045). Similarly, conservative treatment in group 2 was associated with a fivefold to sixfold risk of complications (p = 0.032) and revision surgery (p = 0.023). CONCLUSIONS This study supports the notion that patients with slight elbow laxity can be treated non-operatively, while primary surgical treatment should be performed in patients with moderate and gross laxity to avoid post-traumatic sequelae and decrease revision rates. LEVEL OF EVIDENCE Retrospective Cohort Study, Level III.
Collapse
|
34
|
|
35
|
Interobserver and intraobserver agreement of ligamentous injuries on conventional MRI after simple elbow dislocation. BMC Musculoskelet Disord 2017; 18:85. [PMID: 28219360 PMCID: PMC5319117 DOI: 10.1186/s12891-017-1451-2] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2016] [Accepted: 02/13/2017] [Indexed: 11/10/2022] Open
Abstract
Background The primary objective of this study was to assess the interobserver and intraobserver agreement on ligamentous injuries on conventional magnetic resonance imaging (MRI) in acute simple elbow dislocation. The secondary objectives were to determine the interobserver agreement on the assessment of joint congruity, joint effusion, loose bodies and chondral lesions on conventional MRI. Methods Conventional MRIs (1.5 Tesla, elbow specific surface coil) of 30 patients (40.7 years; range 14–72) with simple elbow dislocations were evaluated by four blinded examiners. An analysis of the interobserver agreement of all raters and for several subgroups (radiologists, orthopaedics, experienced, non-experienced) was performed. The examiners assessed the integrity (intact, partial tear, complete tear) of the lateral collateral ligament (LCL), medial collateral ligament (MCL), extensor and flexor tendons, as well as the presence of joint congruity, joint effusion, loose bodies and chondral lesions. Agreement strength, correlation and proportion of exact agreement were determined for interobserver agreement, and intraobserver agreement analyses. Results Interobserver agreement of all examiners was fair to moderate for collateral ligaments (LCL: 0.441, MCL: 0.275). Exact agreement of all raters was found in 33.3% for the LCL and in 26.7% for the MCL. The both experienced examiners showed highest agreement strength for the LCL (0.619) and the radiologists showed highest agreement strength for the MCL (0.627), the proportion of exact agreement was 60.0% in both categories. A high proportion of exact agreement regarding joint congruity (90%), joint effusion (100%), loose bodies (96.7%) and chondral lesion (80%) was found among the radiologists. The evaluation of the intraobserver agreement revealed slight to substantial agreement (0.227 to 0.718) for the collateral ligaments. Conclusions This study shows difficulties in the evaluation of ligaments by conventional MRI technique as demonstrated by a weak inter- and intraobserver agreement. This should be the basis to develop new MRI quality standards with special focus on coronal oblique reconstructions to improve the evaluation of ligament injuries after simple elbow dislocations.
Collapse
|
36
|
Vascular Impulse Technology versus elevation in the treatment of posttraumatic swelling of extremity fractures: study protocol for a randomized controlled trial. Trials 2017; 18:73. [PMID: 28209169 PMCID: PMC5314677 DOI: 10.1186/s13063-017-1824-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2016] [Accepted: 02/01/2017] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Fractures of the extremities are often complicated by a variable degree of swelling secondary to hemorrhage and soft tissue injury. Patients typically require up to 7 days of inpatient bed rest and elevation to reduce swelling to an acceptable level for operative treatment with internal fixation. Alternatively, an intermittent pneumatic compression device, such as the Vascular Impulse Technology (VIT) system, can be used at the injured extremity to reduce the posttraumatic swelling. The VIT system consists of a pneumatic compressor that intermittently rapidly inflates a bladder positioned under the arch of the hand or the foot, which results in compression of the venous hand or foot plexus. That intermittent compression induces an increased venous velocity and aims to reduce the soft tissue swelling of the affected extremity. METHODS/DESIGN The VIT study is a prospective, monocenter, randomized controlled trial to compare the VIT system with elevation in the treatment of posttraumatic swelling in the case of a fracture of the upper and lower extremity. This study will include 280 patients with fractures of the upper and the lower extremity with nine different injury types. For each of the nine injury types a separate randomization to the two intervention groups (VIT group or control group) will be performed. The primary outcome parameter is the time taken for the swelling to resolve sufficiently to permit surgery. A separate analysis for each of the nine injury types will be performed. DISCUSSION In the proposed study, the effectiveness of the VIT system in the treatment of posttraumatic swelling of upper and lower extremity fractures will be evaluated. TRIAL REGISTRATION German Clinical Trial Register, No. DRKS00010510 . Registered on 17 July 2016.
Collapse
|
37
|
Development and validation of a novel questionnaire for self-determination of the range of motion of wrist and elbow. BMC Musculoskelet Disord 2016; 17:312. [PMID: 27457712 PMCID: PMC4960848 DOI: 10.1186/s12891-016-1171-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/07/2016] [Accepted: 07/08/2016] [Indexed: 11/30/2022] Open
Abstract
Background The aim of this study was to develop and validate a novel self-administered questionnaire for assessing the patient’s own range of motion (ROM) of the wrist and the elbow. Methods In a prospective clinical study from January 2015 to June 2015, 101 consecutive patients were evaluated with a novel, self-administered, diagram-based, wrist motion assessment score (W-MAS) and elbow motion assessment score (E-MAS). The questionnaire was statistically evaluated for test-retest reliability, patient-physician agreement, comparison with healthy population, and influence of covariates (age, gender, affected side and involvement in workers’ compensation cases). Results Assessment of patient-physician agreement demonstrated almost perfect agreement (k > 0.80) with regard to six out of eight items. There was substantial agreement with regard to two items: elbow extension (k = 0.76) and pronation (k = 0.75). The assessment of the test-retest reliability revealed at least substantial agreement (k = 0.70). The questionnaire revealed a high discriminative power when comparing the healthy population with the study group (p = 0.007 or lower for every item). Age, gender, affected side and involvement in workers’ compensation cases did not in general significantly influence the patient-physician agreement for the questionnaire. Conclusion The W-MAS and E-MAS are valid and reliable self-administered questionnaires that provide a high level of patient-physician agreement for the assessments of wrist and elbow ROM. Level of evidence: Diagnostic study, Level II Electronic supplementary material The online version of this article (doi:10.1186/s12891-016-1171-z) contains supplementary material, which is available to authorized users.
Collapse
|
38
|
Intraoperative 3D imaging in the treatment of elbow fractures--a retrospective analysis of indications, intraoperative revision rates, and implications in 36 cases. BMC Med Imaging 2016; 16:24. [PMID: 26987661 PMCID: PMC4797343 DOI: 10.1186/s12880-016-0126-z] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2015] [Accepted: 03/14/2016] [Indexed: 11/12/2022] Open
Abstract
Background Three-dimensional (3D) imaging with a mobile C-arm has proven to be a valuable intraoperative tool in trauma surgery. However, little data is available concerning its use in the treatment of elbow fractures. The aim of the current study was to determine the intraoperative findings and consequences of 3D imaging in the treatment of elbow fractures. Methods Between 2001 and 2015, prospectively collected data of 36 patients who underwent intraoperative 3D imaging during elbow surgery were recorded. The findings and consequences of the intraoperative 3D scans were analyzed in a retrospective chart review. For clinical evaluation the analysis included the patients’ medical history, the injury pattern of the affected elbow and concomitant injuries. Intraoperative and postoperative complications and revision surgeries were evaluated as well. Results In 6 patients (16.7 %) analysis of the intraoperative 3D scan led to an immediate revision due to the detection of intra-articular screw placement (n = 3, 8.3 %) and remaining intra-articular step of >2 mm (n = 3, 8.3 %). In all of these patients, correct implant positioning and anatomical reduction could be achieved after immediate intraoperative revision, which was verified by a repeated intraoperative 3D scan. None of the 36 patients needed surgical revision based on postoperative radiological examinations due to secondary dislocation, wrong implant placement or remaining steps in the articular surface. Conclusions Intraoperative 3D imaging offers additional information about fracture reduction and implant positioning in the treatment of elbow fractures compared to conventional intraoperative 2D imaging. It may therefore reduce the need for revision surgery. The value of intraoperative 3D imaging for clinical outcomes still needs to be assessed.
Collapse
|
39
|
Preoperative shock wave treatment enhances ischemic tissue survival, blood flow and angiogenesis in a rat skin flap model. Int J Surg 2011; 9:292-6. [PMID: 21256991 DOI: 10.1016/j.ijsu.2011.01.003] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2010] [Revised: 11/18/2010] [Accepted: 01/10/2011] [Indexed: 12/30/2022]
Abstract
INTRODUCTION Extracorporeal shock wave treatment (ESWT) has recently been shown to enhance skin flap survival. However, the bio-mechanisms operating during preoperative ESWT remain unclear. The aim of our study was to investigate whether preoperative ESWT can improve blood flow in ischemic skin flaps and to elucidate its possible mechanisms. METHODS 14 male-rats were randomized into two groups and an oversized ventral random-pattern flap was raised. Experimental group received extracorporeal shock-wave treatment (ESWT) with an energy of 500 mJ/mm(2) seven days prior to total flap elevation, while control group received no treatment prior to total flap elevation. Seven days postoperatively, surviving flap area, perfused flap area, microvessel density and VEGF concentration were measured. RESULTS Surviving flap area (59.43 ± 14.72 % to 42.71 ± 10.75 %, p = 0.026), perfused flap area (62.00 ± 8.58 % to 45.14 ± 10.50 %, p = 0.007), microvessel density (18.13 ± 5.11 to 11.09 ± 1.12, p = 0.016) and VEGF to total protein ratio (0.2107 ± 0.0935 to 0.0123 ± 0.0069, p = 0.008) were significantly elevated in the ESWT group. CONCLUSION Preoperative ESWT can improve skin flap survival through enhanced topical blood perfusion and neovascularization via elevation of angio-active factors.
Collapse
|
40
|
THE RELATION OF CHEMICAL STRUCTURE IN CATECHOL COMPOUNDS AND DERIVATIVES TO POISON IVY HYPERSENSITIVENESS IN MAN AS SHOWN BY THE PATCH TEST. ACTA ACUST UNITED AC 2010; 80:275-87. [PMID: 19871415 PMCID: PMC2135472 DOI: 10.1084/jem.80.4.275] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
1. Additional evidence is presented in support of the view which postulates a close chemical and biologic relation between the active ingredients in poison ivy and Japan lac. 2. Biologic evidence, based on the use of the patch test in man, is presented in support of the view that the active ingredient in poison ivy is a catechol derivative with a long, unsaturated side-chain in the 3-position. 3. Of the catechol compounds and derivatives studied, group reactions in patients sensitive to poison ivy leaves or extract were exhibited by the following compounds: 3-pentadecyl catechol (100 per cent of 21 cases), 4-pentadecyl catechol (38 per cent of 21 cases), "urushiol" dimethyl ether (33 per cent of 33 cases), 3-pentadecenyl-1'-veratrole (21 per cent of 14 cases), 3-methyl catechol (14 per cent of 21 cases), and hydrourushiol dimethyl ether (10 per cent of 20 cases). It has been found that 3-geranyl catechol shows a practically constant group reactivity in persons sensitive to poison ivy. 4. The uniformly positive group reaction to 3-pentadecyl catechol is notable since this substance possesses a saturated side-chain, whereas the active ingredient in poison ivy is known to have an unsaturated side-chain. 5. The group reactivity was not restricted to the 3-position, for in some instances 4-pentadecyl catechol also gave group reactions which, however, were less intense and less frequent than those shown by 3-pentadecyl catechol. This indicates that in some cases a long side-chain in the 4 position may be effective in producing group specific reactions. 6. Only an occasional person showed sensitiveness to 3-methyl catechol (short side-chain), and in one instance the group reactivity appeared to be specific for the 3-position. 7. The position of the side-chain in the catechol configuration has some bearing on the degree and incidence of group reactions in persons hypersensitive to poison ivy. 8. Evidence is presented to indicate that the introduction of double bonds in the alkyl side-chain increases the incidence and intensity of group reactions. 9. Methylating the hydroxyl groups in the catechol configuration diminishes strongly the incidence of group reactivity but does not eliminate it entirely in persons hypersensitive to poison ivy. Thus, "urushiol" dimethyl ether (3-pentadecadienyl veratrole) gave group reactions in 33 per cent of 33 persons. 10. Methylating the hydroxyl groups as well as saturating the double bonds in the alkyl side-chain still further diminishes the group reactions but an occasional person hypersensitive to poison ivy may still show positive reaction to such a substance as 3-pentadecyl veratrole (hydrourushiol dimethyl ether). In this respect our results are not in full agreement with those recorded by Toyama who stated that hydrourushiol dimethyl ether is entirely harmless. 11. The significance of the group reactivity displayed by certain veratrole compounds is discussed, and several possible explanations of their behavior are advanced. 12. The group reactions discussed in this paper relate only to various catechol and veratrole compounds. Preliminary studies by us indicate that this sensitiveness extends to other phenolic derivatives. 13. Among the veratrole compounds showing positive reactions, the order of frequency and intensity was: (1) "urushiol" dimethyl ether (average of two double bonds); (2) S-pentadecenyl-1'-veratrole (one double bond); (3) hydrourushiol dimethyl ether (saturated side-chain). It may be noted that 4-pentadecyl veratrole was inactive.
Collapse
|
41
|
Abstract
A high-level expression cassette has been constructed from a TOL plasmid derived from Pseudomonas putida carrying all cis- and trans-acting regulatory elements necessary for transcriptional gene activation in the presence of aromatic hydrocarbons such as toluene. Foreign DNA can be inserted at unique KpnI, SacI, and EcoRI sites 7, 13, and 15 nucleotides downstream of a ribosome binding site. The cassette, flanked by BamHI and EcoRI restriction sites, was inserted into a broad-host-range vector and its efficacy demonstrated in various purple bacteria by monitoring the expression of a reporter gene spectrophotometrically and by SDS-PAGE. High-level induction (80- to 600-fold) was detected in Enterobacteriaceae and in Pseudomonas but was absent or low in Agrobacterium tumefaciens and Rhizobium leguminosarum.
Collapse
|
42
|
Homologies between plasmid and chromosomally-encoded benzoate-oxidizing genes in Pseudomonas putida. Lett Appl Microbiol 1991. [DOI: 10.1111/j.1472-765x.1991.tb00572.x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
43
|
Molecular cloning and expression of a novel catechol 2,3-dioxygenase gene from the benzoate meta-cleavage pathway in Azotobacter vinelandii. JOURNAL OF GENERAL MICROBIOLOGY 1990; 136:607-13. [PMID: 2398344 DOI: 10.1099/00221287-136-4-607] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Azotobacter vinelandii strain 206 degrades benzoate via the meta-cleavage pathway. In a genomic library derived from this organism a clone was obtained which carried and expressed the gene for the third enzyme in this pathway, catechol 2,3-dioxygenase (EC 1.13.11.2), on a 5.9 kb SalI restriction fragment. The structural gene was more precisely mapped on an internal 1.6 kb EcoRI fragment which, after insertion into expression vectors, directed the synthesis of a 33 kDa polypeptide. The gene showed very little or no homology with isofunctional genes derived from Pseudomonas. Comprehensive substrate specificity analysis showed significant differences between the specific activities obtained from the cloned gene product and extracts derived from Azotobacter itself.
Collapse
|
44
|
Molecular analysis of regulatory and structural xyl genes of the TOL plasmid pWW53-4. JOURNAL OF GENERAL MICROBIOLOGY 1987; 133:1149-58. [PMID: 3309179 DOI: 10.1099/00221287-133-5-1149] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
pWW53-4 is a cointegrate between RP4 and the catabolic plasmid pWW53 from Pseudomonas putida MT53, which contains 36 kbp of pWW53 DNA inserted close to the oriV gene of RP4; it encodes the ability to grow on toluene and the xylenes, characteristic of pWW53, as well as resistance to tetracycline, kanamycin and carbenicillin, characteristic of RP4. A physical map of the 36 kbp insert of pWW53 DNA for 11 restriction enzymes is presented, showing that the relative positions of the two xyl operons are different from those on the archetypal TOL plasmid pWW0. The location of the genes for 4-oxalocrotonate decarboxylase (xylI) and 4-oxalocrotonate tautomerase (xylH) were shown by subcloning and enzyme assay to lie at the distal end of the meta pathway operon. Although 2-oxopent-4-enoate hydratase (xylJ) and 4-hydroxy-2-oxovalerate aldolase (xylK) could be detected on a large cloned HindIII fragment, they could not be accurately located on smaller subcloned DNA, but the only credible position for them is between xylF and xylI. The gene order in the meta pathway operon is therefore xylDLEGF(J,K)IH. The regulatory genes xylS and xylR were located close to and downstream of the meta pathway operon, and the restriction map of the DNA in this region, as has previously been shown for the two operons carrying the structural genes, shows similarities with the corresponding region on pWW0. Evidence is also presented for the existence of two promoters, termed P3 and P4, internal to the meta pathway operon which support low constitutive expression of the structural genes downstream in Pseudomonas hosts but not in E. coli.
Collapse
|
45
|
Gene organization of the first catabolic operon of TOL plasmid pWW53: production of indigo by the xylA gene product. J Bacteriol 1987; 169:764-70. [PMID: 3027047 PMCID: PMC211845 DOI: 10.1128/jb.169.2.764-770.1987] [Citation(s) in RCA: 31] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Abstract
The entire operon coding for the enzymes responsible for conversion of toluenes to benzoates has been cloned from TOL plasmid pWW53 and the position of the genes accurately located. The coding region was 7.4 kilobase pairs (kbp) long, and the gene order was operator-promoter region (OP1)-a small open reading frame-xylC (1.6 kbp)-xylA (2.9 kbp)-xylB (1.8 kbp). Within the coding region there was considerable homology with the isofunctional region of the archetypal TOL plasmid pWW0. A central region of 2.9 kbp complemented an xylA (for xylene oxygenase) mutant of Pseudomonas putida mt-2 and was also capable of conferring the ability to convert indole to indigo on strains of Escherichia coli and P. putida. This reaction has been reported previously only for dioxygenases involved in aromatic catabolism but not for monooxygenases. It is proposed that the region encodes xylene oxygenase activity capable of direct monohydroxylation of indole to 3-hydroxyindole (oxindole), which then spontaneously dimerizes to form indigo.
Collapse
|
46
|
[Effect of mitotic density on the probability of survival of patients with thin (less than or equal to 1.5 mm) melanomas]. ZEITSCHRIFT FUR HAUTKRANKHEITEN 1986; 61:15-8, 23-4. [PMID: 3953128] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Our studies dealt with the prognostic significance of the mitotic count for patients with thin (less than or equal to 1.5 mm) melanoma. We determined the mitotic rate of 50 patients who had died of melanoma thinner than 1.5 mm within 8 years (short-term survivors). The specimens were examined by means of a rectangular visual field; thus we could calculate the mitotic count to the square mm of the tumor surface. This outcome was compared to the mitotic rate of 50 long-term survivors who had not died within 8 years and who corresponded to the first group with regard to sex, tumor thickness, as well as tumor site. In both groups, at least 15% of the melanomas did not show any mitotic figure. With females, the average mitotic values were identical in both groups (1.1 vs. 1.15). In males, however, short-term survivors revealed a significantly (p less than 0.001) higher mitotic count (2.2) than long-term survivors (0.75).
Collapse
|
47
|
Evolutionary conservation of genes coding for meta pathway enzymes within TOL plasmids pWW0 and pWW53. J Bacteriol 1985; 164:887-95. [PMID: 2997136 PMCID: PMC214335 DOI: 10.1128/jb.164.2.887-895.1985] [Citation(s) in RCA: 59] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Abstract
Pseudomonas putida MT53 contains a TOL plasmid, pWW53, that encodes toluene-xylene catabolism. pWW53 is nonconjugative, is about 105 to 110 kilobase pairs (kbp) in size, and differs significantly in its restriction endonuclease digestion pattern and incompatibility group from the archetypal TOL plasmid pWW0. An RP4::pWW53 cointegrate plasmid, pWW53-4, containing about 35 kbp of pWW53 DNA, including the entire catabolic pathway genes, was formed, and a restriction map for KpnI, HindIII, and BamHI was derived. The entire regulated meta pathway genes for the catabolism of m-toluate were cloned into pKT230 from pWW53 on a 17.5-kbp HindIII fragment. The recombinant plasmid supported growth on m-toluate when mobilized into plasmid-free P. putida PaW130. A restriction map of the insert for 10 restriction enzymes was derived, and the locations of xylD, xylL, xylE, xylG, and xylF were determined by subcloning and assaying for their gene products in both Escherichia coli and P. putida hosts. Good induction of the enzymes by m-toluate and m-methylbenzyl alcohol but not by m-xylene was measured in P. putida, but little or no regulation was found in E. coli. The restriction map and the gene order showed strong similarities with published maps of the DNA encoding both the entire meta pathway operon (xylDLEGFJIH) and the regulatory genes xylS and xylR on the archetype TOL plasmid pWW0, suggesting a high degree of conservation in DNA structure for the catabolic operon on the two different plasmids.
Collapse
|
48
|
TOL plasmid pWW15 contains two nonhomologous, independently regulated catechol 2,3-oxygenase genes. J Bacteriol 1985; 163:248-55. [PMID: 4008443 PMCID: PMC219105 DOI: 10.1128/jb.163.1.248-255.1985] [Citation(s) in RCA: 53] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
Pseudomonas putida MT15 contains a 250-kilobase-pair (kbp) TOL plasmid pWW15, encoding toluene and xylene catabolism, which undergoes large spontaneous deletions to give two classes of mutants with altered catabolic phenotypes (H. Keil and P. A. Williams, J. Gen. Microbiol, 131:1023-1033, 1985). Two structural genes for catechol 2,3-oxygenase (C23O) were cloned from pWW15. The gene for C23OI was located on the 2.1-kbp XhoI fragment Xh, whereas that for C23OII was found on the 11.5-kbp BamHI fragment BJ. The two restriction fragments and the subcloned regions of them showed no similarity in the pattern of restriction digestion, nor did they hybridize with each other. The substrate specificities of the two enzymes were also substantially different. The two structural genes were separated on pWW15 by about 100 kbp. In plasmid pWW15-510 of a B5 mutant, the 90-kbp deletion in the plasmid removed most of the intervening DNA, but it also deleted 80% of the gene for C23OI from its 3' end. Thus, only C23OII was expressed in the host MT15-510. Conversely, in RP4::pWW15 cointegrate plasmid pWW15-1003, only the C23OI gene was present. The expression of C23O activity from these two derivative plasmids and from the wild-type pWW15 showed that only C23OI was induced by growth in the presence of m-toluate, whereas both activities were induced in the only C23OI was induced by growth in the presence of m-toluate, whereas both activities were induced in the presence of m-xylene. These findings cast doubt on the earlier hypothesis that the deletions in B3 and B5 mutants remove a regulatory gene by which m-toluate induces the enzymes necessary for its own catabolism.
Collapse
|
49
|
Prognostic significance of the patient's sex, tumor site, and mitotic rate in thin (less than or equal to 1.5 mm) melanoma. Arch Dermatol Res 1984; 276:151-5. [PMID: 6476888 DOI: 10.1007/bf00414011] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
Patients who died of a melanoma thinner than 1.5 mm within 96 months (group 1, n = 60) were compared with those having a tumor of the same thickness who had not died in this time period (Group 2, n = 300). Both groups were investigated with respect to differences in patient sex and age and to thickness, diameter, exophytic growth, and site of the melanoma as well as the number of mitoses/mm2 of tumor area. Relatively speaking, more men than women died of a thin melanoma: in Group 1 (deceased) there were 32 men and 28 women, in Group 2 (alive) 58 men and 242 women. The better survival rate of females did not depend on the difference in the predominating melanoma locations (female face and legs; male trunk): In both sites, on the legs and on the trunk, women had a significantly higher 8-year survival rate than men with equally thick tumors. Furthermore, melanomas on the arms and legs of females had a better prognosis than those on the trunk and face. Both the patient's sex and the tumor site seem to influence the survival of melanoma patients. Only in men was the median of mitoses/mm2 of tumor area found to be higher in the first group (2.2) than in the second group (0.75). In women, no marked difference in the mitotic count was found (Group 1:1.1; Group 2:1.15).
Collapse
|
50
|
[Possibilities and limits of physiotherapy for children with cerebral paralysis]. Wien Klin Wochenschr 1970; 82:192-5. [PMID: 5513469] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|