1
|
Corneal aberrations in primary congenital glaucoma and its visual correlation. Int Ophthalmol 2024; 44:209. [PMID: 38683423 DOI: 10.1007/s10792-024-03150-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 04/11/2024] [Indexed: 05/01/2024]
|
2
|
Influence of sex on chronic steroid-induced glaucoma: 24-Weeks follow-up study in rats. Exp Eye Res 2024; 238:109736. [PMID: 38036216 DOI: 10.1016/j.exer.2023.109736] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2023] [Revised: 11/16/2023] [Accepted: 11/21/2023] [Indexed: 12/02/2023]
Abstract
The objective was to evaluate ocular changes based on sex in steroid-induced glaucoma models in rats comparing healthy controls, over 24 weeks follow-up. Eighty-nine Long-Evans rats (38 males and 51 females) with steroid-induced glaucoma were analysed. Two steroid-induced glaucoma models were generated by injecting poly-co-lactic-glycolic acid microspheres loaded with dexamethasone (MMDEX model) and dexamethasone-fibronectin (MMDEXAFIBRO model) into the ocular anterior chamber. Intraocular pressure was measured by rebound tonometer Tonolab®. Neuroretinal function was analysed using dark- and light-adapted electroretinography (Roland consult® RETIanimal ERG), and structure was analysed using optical coherence tomography (OCT Spectralis, Heidelberg® Engineering) using Retina Posterior Pole, Retinal Nerve Fibre Layer and Ganglion Cell Layer protocols over 24 weeks. Males showed statistically (p < 0.05) higher intraocular pressure measurements. In both sexes and models neuroretinal thickness tended to decrease over time. In the MMDEX model, males showed higher IOP values and greatest percentage thickness loss in the Ganglion Cell Layer (p = 0.015). Females receiving MMDEXAFIBRO experienced large fluctuations in thickness, a higher percentage loss (on average) in Retina Posterior Pole (p = 0.035), Retinal Nerve Fibre Layer and Ganglion Cell Layer than aged-matched males, and the highest thickness loss rate by mmHg. Although no difference was found by sex in dark- and light-adapted electroretinography, increased amplitude in photopic negative response was found in MMDEX males and MMDEXAFIBRO females at 12 weeks. Although both glaucoma models used dexamethasone, different intraocular pressure and neuroretinal changes were observed depending on sex and other influential cofactors (fibronectin). Both sex and the induced glaucoma model influenced neuroretinal degeneration.
Collapse
|
3
|
Detection of anti-SARS-CoV-2 antibodies in tears: Ocular surface immunity to COVID-19. ARCHIVOS DE LA SOCIEDAD ESPANOLA DE OFTALMOLOGIA 2023:S2173-5794(23)00083-X. [PMID: 37247663 DOI: 10.1016/j.oftale.2023.05.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Accepted: 03/29/2023] [Indexed: 05/31/2023]
Abstract
PURPOSE To evaluate the presence of SARS-CoV-2 specific IgA and IgG antibodies in tears of unvaccinated and anti-COVID-19 vaccinated subjects with previous history of SARS-CoV-2 infection. To compare results in tears with those in saliva and serum and correlate with clinical data and vaccination regimens. METHODS Cross-sectional study including subjects with a previous history of SARS-CoV-2 infection, both unvaccinated and vaccinated against COVID-19. Three samples were collected: tears, saliva and serum. IgA and IgG antibodies against S-1 protein of SARS-CoV-2 were analyzed with a semi-quantitative ELISA. RESULTS 30 subjects, mean age 36.4 ± 10, males 13/30 (43.3%) with history of mild SARS-CoV-2 infection were included. 13/30 (43.3%) subjects had received a 2-dose regimen and 13/30 (43.3%) a 3-dose regimen of anti-COVID-19 vaccine, 4/30 (13.3%) subjects were unvaccinated. All the participants with full anti-COVID-19 vaccination (2-or 3-doses) presented detectable anti-S1 specific IgA in all three biofluids, tears, saliva and serum. Among unvaccinated subjects, specific IgA was detected in 3/4 subjects in tears and saliva, whereas IgG was not detected. Considering IgA and IgG antibodies titers, no differences were observed between the 2- and 3-dose vaccination regimen. CONCLUSIONS SARS-CoV-2-specific IgA and IgG antibodies were detected in tears after mild COVID-19, highlighting the role of the ocular surface as a first line of defense against infection. Most naturally infected unvaccinated individuals exhibit long-term specific IgA in tears and saliva. Hybrid immunization (natural infection plus vaccination) appears to enhance mucosal and systemic IgG responses. However, no differences were observed between the 2- and 3-dose vaccination schedule.
Collapse
|
4
|
[Detection of anti-SARS-CoV-2 antibodies in tears: Ocular surface immunity to COVID-19]. ARCHIVOS DE LA SOCIEDAD ESPANOLA DE OFTALMOLOGIA 2023:S0365-6691(23)00091-6. [PMID: 37360534 PMCID: PMC10150186 DOI: 10.1016/j.oftal.2023.03.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Accepted: 03/29/2023] [Indexed: 06/28/2023]
Abstract
Purpose To evaluate the presence of SARS-CoV-2 specific IgA and IgG antibodies in tears of unvaccinated and anti-COVID-19 vaccinated subjects with previous history of SARS-CoV-2 infection. To compare results in tears with those in saliva and serum and correlate with clinical data and vaccination regimens. Methods Cross-sectional study including subjects with a previous history of SARS-CoV-2 infection, both unvaccinated and vaccinated against COVID-19. Three samples were collected: tears, saliva and serum. IgA and IgG antibodies against S-1 protein of SARS-CoV-2 were analyzed with a semi-quantitative ELISA. Results Thirty subjects, mean age 36.4 ± 10, males 13/30 (43.3%) with history of mild SARS-CoV-2 infection were included. 13/30 (43.3%) subjects had received a 2-dose regimen and 13/30 (43.3%) a 3-dose regimen of anti-COVID-19 vaccine, 4/30 (13.3%) subjects were unvaccinated. All the participants with full anti-COVID-19 vaccination (2-or 3-doses) presented detectable anti-S1 specific IgA in all 3 biofluids, tears, saliva and serum. Among unvaccinated subjects, specific IgA was detected in 3/4 subjects in tears and saliva, whereas IgG was not detected. Considering IgA and IgG antibodies titers, no differences were observed between the 2- and 3-dose vaccination regimen. Conclusions SARS-CoV-2-specific IgA and IgG antibodies were detected in tears after mild COVID-19, highlighting the role of the ocular surface as a first line of defense against infection. Most naturally infected unvaccinated individuals exhibit long-term specific IgA in tears and saliva. Hybrid immunization (natural infection plus vaccination) appears to enhance mucosal and systemic IgG responses. However, no differences were observed between the 2- and 3-dose vaccination schedule.
Collapse
|
5
|
Trabecular microbypass stent to treat ocular hypertension after intravitreal injection of a dexamethasone implant. J Fr Ophtalmol 2021; 44:e591-e594. [PMID: 34281762 DOI: 10.1016/j.jfo.2021.01.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2020] [Revised: 01/14/2021] [Accepted: 01/14/2021] [Indexed: 10/20/2022]
|
6
|
Comparision of intraocular pressure measured using the new icare 200™ rebound tonometer and the Perkins™ applanation tonometer in healthy subjects and in patients with primary congenital glaucoma. ACTA ACUST UNITED AC 2020; 96:175-180. [PMID: 32690372 DOI: 10.1016/j.oftal.2020.06.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Revised: 05/27/2020] [Accepted: 06/05/2020] [Indexed: 10/23/2022]
Abstract
OBJECTIVE To compare intraocular pressure (IOP) measurements obtained using the Icare 200™ (IC200) rebound tonometer and the hand-held version of the Goldmann Applanation Tonometer (Perkins™ tonometer, GAT) in patients with primary congenital glaucoma (PCG) and in healthy subjects. MATERIAL AND METHODS A total of 42 eyes of healthy subjects (G1) and 40 patients with PCG (G2) were analysed. The following clinical data were collected: gender, age, Cup/Disc ratio, central corneal thickness (CCT). IOP was determined in the examination room using the IC200 and GAT tonometers, in the same order. Agreement between both tonometers was determined using the intraclass correlation coefficient (ICC) and Bland-Altman plot. A linear regression analysis was used to establish the IOP was affected by the studied variables. RESULTS Mean IOP between both tonometers (IC200 minus GAT) was: G1=15.91 (2.57) mmHg vs. 15.06 (2.12) mmHg (mean difference, MD=0.84 (0.50) mmHg; P<.101) and G2=20.10 (6.37) vs.19.12 (5.62) (MD=0.98 (1.36); P=.474). Excellent agreement was found between IC200 and GAT in both groups (ICC=G1: 0.875 (95% CI; 0.768-0.933; P<.001); G2: 0.924 (95% CI; 0.852-0.961; P<.001), and there was a statistically significant correlation between the IOP difference measured with IC200 and GAT and CCT in G1 (B=0.021; 95% CI; 0.005-0.037; P=.008), but was not statistically significant in G2. CONCLUSION There was excellent agreement between the IC200 and GAT tonometers, both in healthy subjects and PCG, with a trend to overestimate IOP when measured with IC200. There was no influence by CCT on IOP measurements in patients with PGC.
Collapse
|
7
|
DSAEK in a buphtalmic eye with Haab striae, case report. J Fr Ophtalmol 2019; 42:e293-e295. [PMID: 31133399 DOI: 10.1016/j.jfo.2018.12.032] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2018] [Revised: 11/29/2018] [Accepted: 12/13/2018] [Indexed: 11/26/2022]
|
8
|
CyPass stent withdrawal: The end of suprachoroidal MIGS? ACTA ACUST UNITED AC 2018; 94:1-3. [PMID: 30522701 DOI: 10.1016/j.oftal.2018.10.016] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2018] [Accepted: 10/11/2018] [Indexed: 10/27/2022]
|
9
|
Impact of Intraocular Pressure after Filtration Surgery on Visual Field Progression in Primary Open-Angle Glaucoma. Eur J Ophthalmol 2018; 17:357-62. [PMID: 17534816 DOI: 10.1177/112067210701700313] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
PURPOSE To compare visual field progression after trabeculectomy in eyes showing a postoperative intraocular pressure (IOP) less than or equal to 16 mmHg and eyes with an IOP of 17 to 21 mmHg. METHODS A retrospective cohort study design was used. A total of 101 eyes of 101 consecutive patients undergoing trabeculectomy for primary open-angle glaucoma (POAG) with a postoperative IOP less than or equal to 21 mmHg were divided into two groups: Group 1 included eyes showing a postoperative IOP less than or equal to 16 mmHg at all visits and Group 2 included eyes with a postoperative IOP between 17 and 21 mmHg. In turn, each of these groups was divided into two subgroups according to whether treatment was required for IOP control. Glaucomatous visual field control during follow-up was compared between the subject groups. RESULTS Kaplan-Meier analysis revealed glaucomatous visual field control in 98.53% of the eyes in Group 1 and 89.06% of those in Group 2 at 5 years, the difference between the groups being significant. CONCLUSIONS Glaucomatous disease progression is less frequent when IOP is less than or equal to 16 mmHg in all the follow-up visits after trabeculectomy. The results indicate a definite benefit of low IOP in visual field control.
Collapse
|
10
|
Short-Term Anatomic Effect of Ranibizumab for Polypoidal Choroidal Vasculopathy. Eur J Ophthalmol 2018; 18:645-8. [DOI: 10.1177/112067210801800427] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
11
|
Retinal Angiomatous Proliferation Reactivation 6 Months after High-Dose Intravitreal Acetonide Triamcinolone and Photodynamic Therapy. Eur J Ophthalmol 2018; 17:979-82. [DOI: 10.1177/112067210701700619] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Purpose To describe the incidence of retinal angiomatous proliferation (RAP) reactivation after combined treatment with a high-dose intravitreal triamcinolone acetonide (IVTA) and photodynamic therapy (PDT) at 1-year follow-up. Methods All patients had undergone a full ophthalmic examination. High-dose IVTA (20 mg) was injected via pars plana. Four to 7 days later, PDT was delivered. Results Fourteen eyes of 13 patients were included. Eight lesions (57%) reopened and needed retreatment with combined therapy at 6 months follow-up. At 1-year follow up, the lesion was obliterated in nine cases (64.2%) and best-corrected visual acuity improved from 0.87 logMar (range, 0.7–1) to 0.79 logMar (range, 0.5–1). Conclusions Combined therapy using high-dose IVTA and PDT is beneficial in stabilizing RAP. However, a high incidence of RAP reactivation has been observed at 6 months, even with a high-dose IVTA injection.
Collapse
|
12
|
Ocular Inflammatory Signs Observed in a Cohort of Spanish Patients with Behçet Disease and Ocular Inflammation. Eur J Ophthalmol 2018; 18:563-6. [DOI: 10.1177/112067210801800410] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
13
|
Enzymatic Activity of CYP1B1 in primary congenital glaucoma goniodysgenesis and its relation with histological alterations. Acta Ophthalmol 2017. [DOI: 10.1111/j.1755-3768.2017.0s067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
14
|
Results for the Synergy trial: use of iStent in open angle glaucoma. Acta Ophthalmol 2016. [DOI: 10.1111/j.1755-3768.2016.0189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
15
|
The view of a director of training. Acta Ophthalmol 2016. [DOI: 10.1111/j.1755-3768.2016.0224] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
16
|
Clinical classification and medical treatment options in childhood glaucoma. ARCHIVOS DE LA SOCIEDAD ESPANOLA DE OFTALMOLOGIA 2015; 90:557-561. [PMID: 26358844 DOI: 10.1016/j.oftal.2015.07.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2015] [Revised: 04/10/2015] [Accepted: 07/01/2015] [Indexed: 06/05/2023]
|
17
|
Diagnostic Ability of Macular Nerve Fiber Layer Thickness Using New Segmentation Software in Glaucoma Suspects. Invest Ophthalmol Vis Sci 2014; 55:8343-8. [DOI: 10.1167/iovs.14-15501] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
18
|
Abstract
PURPOSE To present a unique case of a 33-year-old woman using paroxetine who presented with acute unilateral visual loss due to chronic angle-closure glaucoma. METHODS Case report. RESULTS A 33-year-old women who had been under paroxetine treatment for the past four months presented at the emergency room due to a sudden loss of visual acuity (VA) in the left eye (LE). Narrow anterior chamber was detected. Intraocular pressure (IOP) was 29 mmHg right eye (RE) and 42 mm Hg LE. A fundus exam revealed a cup-to-disc ratio of 0.9-1 for the LE and of 0.1-0.2 for the RE. Paroxetine treatment was suspended, and after 48 h IOP was 10 mm Hg in both eyes (BE). ND-YAG laser iridotomy was performed in BE. In the subsequent visit, IOP was 25 mm Hg in the RE and 41 mm Hg in the LE; on her own initiative the patient had resumed paroxetine treatment. After requesting the patient again to stop taking the anti-depressant, IOP was 10 mm Hg in BE in the next exam 48 h later. CONCLUSIONS As far as we are aware, there are no other reports of chronic angle-closure glaucoma related to the use of paroxetine. We thus consider that, before initiating treatment with this drug, patients should be informed of its potential ocular risks and they should be subjected to an ophthalmologic examination before its use is authorized.
Collapse
|
19
|
Comparaison de l’épaisseur cornéenne centrale mesurée par pachymétrie ultrasonore et par Pentacam chez les patients sains et les patients avec glaucome primaire à angle ouvert. J Fr Ophtalmol 2012; 35:333-7. [DOI: 10.1016/j.jfo.2011.07.012] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2011] [Revised: 06/24/2011] [Accepted: 07/19/2011] [Indexed: 11/30/2022]
|
20
|
Response to Weinreb et al. Eye (Lond) 2010. [DOI: 10.1038/eye.2010.79] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
|
21
|
Untreated 24-h intraocular pressures measured with Goldmann applanation tonometry vs nighttime supine pressures with Perkins applanation tonometry. Eye (Lond) 2009; 24:1252-8. [DOI: 10.1038/eye.2009.300] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
|
22
|
A 6-month assessment of bimatoprost 0.03% vs timolol maleate 0.5%: hypotensive efficacy, macular thickness and flare in ocular-hypertensive and glaucoma patients. Eye (Lond) 2005; 21:164-8. [PMID: 16254590 DOI: 10.1038/sj.eye.6702149] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
AIM To compare 6 months of treatment with bimatoprost and timolol in terms of their hypotensive efficacy and secondary effects, including changes in macular thickness and the inflammatory reaction induced in the anterior chamber. METHODS A prospective, randomized, parallel-group trial performed on 30 eyes of 30 patients per group. The main outcome measure was the difference between the IOP value taken between the baseline visit and the 6-month-visit. Macular thickness determined through optical coherence tomography and anterior chamber inflammation estimated using the laser flare meter was also evaluated. Adverse events were recorded during the study period. RESULTS Bimatoprost treatment gave rise to a significantly lower mean IOP than timolol in all follow-up visits as from the first month (P<0.05). Bimatoprost achieved high percentage IOP reductions from baseline in a significantly higher proportion of patients (P<0.05). Macular thickness and anterior chamber flare failed to vary significantly both between the two groups and within each group during the 6-month evaluation (P>0.05). CONCLUSIONS Bimatoprost 0.03% once daily showed a greater efficacy then timolol 0.05% twice daily in patients with elevated IOP. No significant differences were detected in macular thickness or anterior uveitis using optical coherence tomography and laser flare photometry.
Collapse
|
23
|
Concomitant administration of travoprost and brinzolamide versus fixed latanoprost/timolol combined therapy: three-month comparison of efficacy and safety. Curr Med Res Opin 2004; 20:1333-9. [PMID: 15383180 DOI: 10.1185/030079904125004529] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
PURPOSE To compare the efficacy and safety of the concomitant administration of travoprost 0.004% once daily and brinzolamide 0.1% twice daily with those of a fixed combination of latanoprost 0.005%/timolol 0.5% once daily. RESEARCH, DESIGN AND METHODS Forty-four patients with primary open-angle glaucoma or ocular hypertension with elevated IOP insufficiently responsive to monotherapy were randomly assigned to one of the two treatment groups: concomitant administration of travoprost 0.004% once daily and brinzolamide 0.1% twice daily (TB group: 22 patients) or latanoprost 0.005% plus timolol 0.5% once daily (LT group: 22 patients). Visits were undertaken at screening (current ocular hypotensive therapy was discontinued), baseline (randomization), and after 2 weeks, 1 month, 2 months and 3 months of therapy. MAIN OUTCOME MEASURES IOP was determined at 9 a.m., 12 p.m. and 4 p.m. at each study visit, and diurnal IOP was calculated as the mean of these recordings. Adverse events were recorded at each visit. RESULTS IOP at the baseline visit was similar in both groups. Overall mean IOP was significantly lower in the TB as compared to the LT group after 1 month, 2 month and 3 month follow-up; only 9 a.m. measurements were significantly different, reaching a maximum difference (16.9 +/- 0.9 mmHg vs 18.4 +/- 1.8 mmHg, p < 0.001) at the 3 month check. The percentage of responders (IOP decrease > or = 30%) was higher in the TB group. Both treatments were well tolerated and there were no cases of withdrawal from treatment. CONCLUSIONS Travoprost 0.004% and brinzolamide 0.1% concomitant therapy showed a greater efficacy than the fixed latanoprost 0.005%/timolol 0.5% combination in terms of absolute IOP decreases. Travoprost/brinzolamide therapy also offered the advantages of a greater percentage of responders.
Collapse
|
24
|
Selective vs argon laser trabeculoplasty: hypotensive efficacy, anterior chamber inflammation, and postoperative pain. Eye (Lond) 2004; 18:498-502. [PMID: 15131681 DOI: 10.1038/sj.eye.6700695] [Citation(s) in RCA: 102] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
PURPOSE To compare selective laser trabeculoplasty (SLT) with conventional argon laser trabeculoplasty (ALT) in terms of hypotensive efficacy, anterior chamber inflammation, and pain reported by the patients treated. METHODS A prospective study performed on 40 consecutive patients. Group I (n = 20): SLT 180 degrees. Group II (n = 20): ALT 180 degrees. Intraocular pressure, flare (Laser-Flare-Meter, Kowa FM-500, Japan), and pain (Visual Analogue Scale) were measured before treatment and 1 h, 24 h,1 week, and 1, 3 and 6 months after treatment. Statistically significant differences were determined by an independent-sample Student's t-test. RESULTS At 6 months after treatment, pressure reduction was similar in both groups: SLT 22.2% (range 0-36.3%) and ALT 19.5% (range 0-30.2%), P= 0.741. The energy released during treatment was significantly lower in SLT (48.3 SD 7.4 mJ) than in ALT (4321 SD 241.7 mJ), P < 0.001. At 1 h after treatment,anterior chamber flare was also lower in SLT(13.3 SD 6.3 vs 20.7 SD 7.4 photons/ms),P = 0.003. Pain reported by the patients during the treatment was significantly lower in SLT(2.0 SD 0.7 vs 4.3 SD 1.3), P<0.001. CONCLUSIONS The hypotensive efficacy of both lasers at the end of follow-up was similar. The energy released during treatment and inflammation produced in the anterior chamber in the immediate postoperative period were significantly lower for SLT. The SLT procedure was better tolerated, producing less discomfort during treatment than conventional trabeculoplasty with argon.
Collapse
|
25
|
Abstract
OBJECTIVE To describe the safety, effectiveness, and predictability of laser in situ keratomileusis (LASIK) for correcting residual myopia after primary photorefractive keratectomy (PRK). DESIGN A retrospective, noncomparative case series. PARTICIPANTS AND INTERVENTION Thirty-six consecutive eyes of 30 patients underwent LASIK after primary PRK. A Multiscan Schwind excimer laser was used for LASIK enhancement. MAIN OUTCOME MEASURES Uncorrected visual acuity (UCVA), best spectacle-corrected visual acuity, refraction, videokeratography, and complications were determined before and after LASIK retreatment. Follow-up was at least 12 months. RESULTS Before LASIK, 11.11% of eyes showed a UCVA of 20/40 or better. This increased to 94.44% 12 months after LASIK. A UCVA of 20/25 or better was achieved in 0% before and in 72.22% after retreatment. Refraction +/-0.5 diopters (spherical equivalent) represented 0% of eyes before and 77.78% of eyes after enhancement. Before LASIK, two eyes had significant haze. Haze remained in these two eyes and appeared in another eye. CONCLUSIONS Laser in situ keratomileusis proved to be safe and effective for treating residual myopia after PRK. Care must be taken when considering LASIK retreatment in patients with significant haze after primary PRK.
Collapse
|
26
|
Orbital cup. A device to facilitate ultrasound biomicroscopic examination of pars plana and peripheral retina. ARCHIVES OF OPHTHALMOLOGY (CHICAGO, ILL. : 1960) 1997; 115:1475-6. [PMID: 9366688 DOI: 10.1001/archopht.1997.01100160645026] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Ultrasound biomicroscopy is a useful technique for anterior segment evaluation; however, examination of the pars plana and the peripheral retina is difficult. We describe a method that facilitates ultrasound biomicroscopic examination of these areas using using a modified swimming goggle(orbital cup) and an eyelid speculum. With this method, not only the pars plana but also structures up to 15 mm from the temporal limbus can be readily imaged.
Collapse
|
27
|
Abstract
PURPOSE To report the diagnosis of pars planitis on the basis of ultrasound biomicroscopy images. METHODS The Humphrey ultrasound biomicroscope was used for examination of the right eye of a 17-year-old boy, referred to our clinic because of blurred vision. The lens showed a posterior subcapsular cataract precluding fundus visualization. RESULTS Ultrasound biomicroscopy showed a homogeneous mass of medium reflectivity over the pars plana. Lensectomy and vitrectomy confirmed the diagnosis. CONCLUSION This brief case report points out the utility of ultrasound biomicroscopy in diagnosing pars planitis in cases of media opacities.
Collapse
|