1
|
Interchanging Reusable and Disposable Nebulizers Used with Home-Based Compressors May Result in Inconsistent Dosing: A Laboratory Investigation with Device Combinations Supplied to the US Healthcare Environment. Pulm Ther 2024:10.1007/s41030-024-00256-0. [PMID: 38622443 DOI: 10.1007/s41030-024-00256-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2024] [Accepted: 03/12/2024] [Indexed: 04/17/2024] Open
Abstract
INTRODUCTION Reusable nebulizer-compressor combinations deliver inhaled medications for patients with chronic lung diseases. On hospital discharge, the patient may take home the disposable nebulizer that was packaged and combine it with their home compressor. Though this practice may reduce waste, it can increase variability in medication delivery. Our study compared several reusable and disposable nebulizers packaged with compressor kits used in the US. We included a common disposable hospital nebulizer that may not be supplied with popular home kits but may be brought home after a hospitalization or emergency department visit. We focused on fine droplet mass < 4.7 μm aerodynamic diameter (FDM<4.7 μm), associated with medication delivery to the airways of the lungs. METHODS We evaluated the following nebulizer-compressor combinations (n = 5 replicates): 1. OMBRA® Table Top Compressor with MC 300® reusable and Airlife™ MistyMax™ 10® disposable nebulizer, 2. Sami-the-Seal® compressor with SideStream® reusable and disposable nebulizers and Airlife™ MistyMax 10™ disposable nebulizer, 3. VIOS® compressor with LC Sprint® reusable, and VixOne® and Airlife™ MistyMax™ disposable nebulizers, 4. Innospire® Elegance® compressor with SideStream® reusable and disposable nebulizers and Airlife™ MistyMax 10™ disposable nebulizer, 5. Willis-the-Whale® compressor with SideStream® reusable and disposable nebulizers and Airlife™ MistyMax 10™ disposable nebulizer, 6. Pari PRONEB® Max compressor with LC Sprint® reusable and Airlife™ MistyMax 10™ disposable nebulizer. We placed a 3-ml albuterol solution (0.833 mg/ml) in each nebulizer. A bacterial/viral filter was attached to the nebulizer mouthpiece to capture emitted medication, with the filter exit coupled to a simulator of a tidal breathing adult (rate = 10 cycles/min; Vt = 600 ml; I/E ratio = 1:2). The filter was replaced at 1-min intervals until onset of sputter. Droplet size distributions (n = 5 replicates/system) were determined in parallel by laser diffractometry. RESULTS Cumulative FDM<4.7 μm varied from 381 ± 33 μg for the best performing combination (Proneb/LC-Sprint) to 150 ± 21 μg for the system with the lowest output (VIOS®/MistyMax 10™). CONCLUSIONS Substituting one nebulizer for another can result in large differences in medication delivery to the lungs.
Collapse
|
2
|
Laboratory Performance Testing of Aqueous Nasal Inhalation Products for Droplet/Particle Size Distribution: an Assessment from the International Pharmaceutical Aerosol Consortium on Regulation and Science (IPAC-RS). AAPS PharmSciTech 2023; 24:208. [PMID: 37817001 DOI: 10.1208/s12249-023-02665-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Accepted: 09/21/2023] [Indexed: 10/12/2023] Open
Abstract
Although nasal inhalation products are becoming more and more important for the delivery of medicines, characterization of these products for quality control and assessment of bioequivalence is complicated. Most of the problems encountered are associated with the assessment of aerodynamic droplet/particle size distribution (APSD). The droplets produced by the various nasal devices are large, and for suspension products, individual droplets may contain multiple drug particles or none at all. Assessment of suspension products is further complicated by the presence of solid excipient particles. These complications make it imperative that the limitations of the instruments used for characterization as well as the underlying assumptions that govern the interpretation of data produced by these instruments are understood. In this paper, we describe various methodologies used to assess APSD for nasal inhalation products and discuss proper use, limitations, and new methodologies on the horizon.
Collapse
|
3
|
Good Practices for the Laboratory Performance Testing of Aqueous Oral Inhaled Products (OIPs): an Assessment from the International Pharmaceutical Aerosol Consortium on Regulation and Science (IPAC-RS). AAPS PharmSciTech 2023; 24:73. [PMID: 36869256 DOI: 10.1208/s12249-023-02528-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Accepted: 02/06/2023] [Indexed: 03/05/2023] Open
Abstract
Multiple sources must be consulted to determine the most appropriate procedures for the laboratory-based performance evaluation of aqueous oral inhaled products (OIPs) for the primary measures, dose uniformity/delivery, and aerodynamic particle (droplet) size distribution (APSD). These sources have been developed at different times, mainly in Europe and North America, during the past 25 years by diverse organizations, including pharmacopeial chapter/monograph development committees, regulatory agencies, and national and international standards bodies. As a result, there is a lack of consistency across all the recommendations, with the potential to cause confusion to those developing performance test methods. We have reviewed key methodological aspects of source guidance documents identified by a survey of the pertinent literature and evaluated the underlying evidence supporting their recommendations for the evaluation of these performance measures. We have also subsequently developed a consistent series of solutions to guide those faced with the various associated challenges when developing OIP performance testing methods for oral aqueous inhaled products.
Collapse
|
4
|
Moving Forward from "Fine Particle Fraction: The Good and the Bad". J Aerosol Med Pulm Drug Deliv 2022; 35:225-226. [PMID: 35508023 DOI: 10.1089/jamp.2022.0017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
5
|
Particle Size Measurements from Orally Inhaled and Nasal Drug Products. J Aerosol Med Pulm Drug Deliv 2021; 34:325-345. [PMID: 34860563 DOI: 10.1089/jamp.2021.29047.jpm] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Particle size measurement of aerosolized particles from orally inhaled and nasal drug products (OINDPs) can be used to assess the likely deposition distribution in the human respiratory tract (HRT). Size is normally expressed in terms of aerodynamic diameter, since this scale directly relates to the mechanics of particle transport from inhaler to deposition locations. The multistage cascade impactor (CI) is the principal apparatus used to size fractionate aerosols in terms of their aerodynamic particle size distributions (APSDs). Clinically meaningful metrics, such as fine and coarse particle mass fractions, can be determined from the cumulative mass-weighted APSD. In effective data analysis (EDA), CI data are reduced to small and large particle mass. The sum and ratio of these metrics are used to characterize impactor-sized mass, without the need for stage groupings or other APSD interpretation. Aerosol characterization by full-resolution CI is complex, and so, an abbreviated impactor measurement has recently come to prominence. Here, multiple stages of the CI are reduced to just one or two size fractionating stages so that measures of fine (and extrafine) particle mass from a two-stage system can be directly determined without the need to group the mass of active pharmaceutical ingredient (API) on adjacent stages. Time-of-flight-based methods determine APSD more rapidly but require refinements such as single-particle mass spectroscopy to relate size measurements to API content. Alternatives for size characterizing OINDP aerosols are few; laser diffractometry is by far the most important, especially for nasal sprays and solution-based orally inhaled formulations in which there is no confounding of data from suspended excipient(s). Laser-phase Doppler anemometry (L-PDA) has also been shown to be useful for nasal sprays. If aerodynamic size-related information is not a priority, optical microscopy combined with Raman chemical imaging offers prospects for separate determination of API components in combination product-generated aerosols.
Collapse
|
6
|
Non-Pharmaceutical Techniques for Obstructive Airway Clearance Focusing on the Role of Oscillating Positive Expiratory Pressure (OPEP): A Narrative Review. Pulm Ther 2021; 8:1-41. [PMID: 34860355 PMCID: PMC8640712 DOI: 10.1007/s41030-021-00178-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Accepted: 10/29/2021] [Indexed: 11/26/2022] Open
Abstract
Mucus secretion in the lungs is a natural process that protects the airways from inhaled insoluble particle accumulation by capture and removal via the mucociliary escalator. Diseases such as cystic fibrosis (CF) and associated bronchiectasis, as well as chronic obstructive pulmonary disease (COPD), result in mucus layer thickening, associated with high viscosity in CF, which can eventually lead to complete airway obstruction. These processes severely impair the delivery of inhaled medications to obstructed regions of the lungs, resulting in poorly controlled disease with associated increased morbidity and mortality. This narrative review article focuses on the use of non-pharmacological airway clearance therapies (ACTs) that promote mechanical movement from the obstructed airway. Particular attention is given to the evolving application of oscillating positive expiratory pressure (OPEP) therapy via a variety of devices. Advice is provided as to the features that appear to be the most effective at mucus mobilization.
Collapse
|
7
|
Urgent Appeal from International Society for Aerosols in Medicine (ISAM) During COVID-19: Clinical Decision Makers and Governmental Agencies Should Consider the Inhaled Route of Administration: A Statement from the ISAM Regulatory and Standardization Issues Networking Group. J Aerosol Med Pulm Drug Deliv 2020; 33:235-238. [DOI: 10.1089/jamp.2020.1622] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022] Open
|
8
|
Internal Volumes of Pharmaceutical Compendial Induction Port, Next-Generation Impactor With and Without Its Pre-separator, and Several Configurations of the Andersen Cascade Impactor With and Without Pre-separator. J Aerosol Med Pulm Drug Deliv 2020; 33:214-229. [PMID: 32101074 PMCID: PMC7407003 DOI: 10.1089/jamp.2019.1590] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Background: Determination of aerosol aerodynamic particle size distributions (APSD) from dry-powder inhalers (DPIs), following quality control procedures in the pharmacopeial compendia, requires that the flow through the measurement apparatus, comprising induction port, optional pre-separator, and cascade impactor, starts from zero on actuation of the inhaler, using a solenoid valve to apply vacuum to the apparatus exit. The target flow rate, governed by the inhaler resistance, is reached some time afterward. Understanding the behavior of the DPI design-specific flow rate-rise time curve can provide information about the kinetics of the initial powder dispersion in the inhaler and subsequent transport through the APSD measurement equipment. Accurate and precise measures of the internal volume of each component of this apparatus are required to enable reliable relationships to be established between this parameter and those defining the flow rate-rise time curve. Methods: An improved method is described that involves progressive withdrawal of an accurately known volume of air from the interior passageways of the apparatus-on-test that are closed to the outside atmosphere. This approach is applicable for determining internal volumes of components having complex internal geometries. Filling some components with water, along with volumetric or gravimetric measurement, has proven valuable for the induction port and for checking other measurements. Results: Values of internal volume are provided for the USP (United States Pharmacopeia)/PhEur (European Pharmacopoeia) induction port, the Next-Generation Impactor (NGI™) with and without its pre-separator, and various Andersen 8-stage cascade impactor configurations with and without their pre-separators. Conclusion: These data are more accurate and precise, and therefore update those reported by Copley et al.
Collapse
|
9
|
Determination of Passive Dry Powder Inhaler Aerodynamic Particle Size Distribution by Multi-Stage Cascade Impactor: International Pharmaceutical Aerosol Consortium on Regulation & Science (IPAC-RS) Recommendations to Support Both Product Quality Control and Clinical Programs. AAPS PharmSciTech 2019; 20:206. [PMID: 31147791 DOI: 10.1208/s12249-019-1416-x] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2019] [Accepted: 05/09/2019] [Indexed: 11/30/2022] Open
Abstract
The multi-stage cascade impactor (CI) is the mainstay method for the determination of the aerodynamic particle size distribution (APSD) of aerosols emitted from orally inhaled products (OIPs). CIs are designed to operate at a constant flow rate throughout the measurement process. However, it is necessary to mimic an inhalation maneuver to disperse the powder into an aerosol when testing passive dry powder inhalers (DPIs), which constitute a significant portion of available products in this inhaler class. Methods in the pharmacopeial compendia intended for product quality assurance initiate sampling by applying a vacuum to the measurement apparatus using a timer-operated solenoid valve located downstream of the CI, resulting in a period when the flow rate through the impactor rapidly increases from zero towards the target flow rate. This article provides recommendations for achieving consistent APSD measurements, including selection of the CI, pre-separator, and flow control equipment, as well as reviewing considerations that relate to the shape of the flow rate-sampling time profile. Evidence from comparisons of different DPIs delivering the same active pharmaceutical ingredients (APIs) is indicative that the compendial method for APSD measurement is insensitive as a predictor of pharmacokinetic outcomes. Although inappropriate for product quality testing, guidance is therefore provided towards adopting a more clinically realistic methodology, including the use of an anatomically appropriate inlet and mimicking patient inhalation at the DPI while operating the CI at constant flow rate. Many of these recommendations are applicable to the testing of other OIP classes.
Collapse
|
10
|
Measurement of Aerodynamic Particle Size Distribution of Orally Inhaled Products by Cascade Impactor: How to Let the Product Specification Drive the Quality Requirements of the Cascade Impactor. AAPS PharmSciTech 2019; 20:57. [PMID: 30623259 DOI: 10.1208/s12249-018-1276-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2018] [Accepted: 12/11/2018] [Indexed: 11/30/2022] Open
Abstract
The multi-stage inertial cascade impactor is used to determine the mass-weighted aerodynamic particle size distribution (APSD) as a critical quality attribute for orally inhaled products (OIPs). These apparatuses progressively size-fractionate the aerosol passing through a series of stages containing one or more nozzles, by increasing particle velocity. Nozzle sizes for a given multi-nozzle stage can be described collectively by effective diameter ([Formula: see text]), related to the cut-point size, providing the link to aerodynamic diameter. Users undertake stage mensuration periodically to assure that each stage [Formula: see text] remains within the manufacturer's tolerance, but there is no guidance on how frequently such checks should be made. We examine the philosophy that particle size-related specifications of the OIP should determine when an impactor is mensurated. Taking an example of a dry powder inhaler-generated aerosol sampled via a Next Generation Impactor with pre-separator, we find that there are only three critical stages that could have a material effect on the measured APSD specified as four groupings of stages following current regulatory practice. Furthermore, [Formula: see text] for the most critical stage having the smallest nozzle sizes could be relaxed by a factor of four or more before risking an inability to measure the mass fraction of API in the group containing the finest particles to a specification within ± 10% of nominal. We therefore conclude that users should consider letting the specification for APSD performance of an OIP in terms of accepted stage groupings drive the impactor quality requirements and frequency that stage mensuration is undertaken.
Collapse
|
11
|
Evaluation of Nasal Inlet Ports Having Simplified Geometry for the Pharmacopeial Assessment of Mass Fraction of Dose Likely to Penetrate Beyond the Nasopharynx: a Preliminary Investigation. AAPS PharmSciTech 2018; 19:3723-3733. [PMID: 30225778 DOI: 10.1208/s12249-018-1179-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2018] [Accepted: 09/03/2018] [Indexed: 11/30/2022] Open
Abstract
Nasal cavity breakthrough to the airways of the lungs is associated with nasally inhaled droplets whose size is smaller than ca. 10 μm aerodynamic diameter that behave as an aerosol rather than a spray in terms of their transport. The purpose of the present laboratory-based study was to evaluate a nasal product quality control procedure involving a new inlet for the quantification of mass of such droplets emitted by commercially available aqueous nasal spray pump products by cascade impactor. This inlet is more representative of the adult nasal vestibule in terms of entry angle for the spray as well as internal volume for plume expansion. Sampling was also undertaken via a spherical 1-L glass expansion vessel as inlet, previously established for quantification of these aerosol droplets. The selected solution- and suspension-formulated products containing azelastine and fluticasone propionate respectively were shown to contain < 1% of the total spray mass per actuation associated with droplets < 14.1 μm aerodynamic diameter. These measurements were consistent with laser diffraction-based measurements of the entire droplet size distribution. Comparable measures of aerosol droplet mass fraction were obtained when the spray was sampled by the cascade impactor method using either the 1-L glass expansion chamber or the new metal inlet as entry for the spray produced by either product evaluated. We conclude that the metal inlet has the potential to be adopted as a suitable induction port in the assessment of nasal product quality, where currently no standardized inlet exists.
Collapse
|
12
|
The Effects of Quality and Timing of Venepuncture on Markers of Blood Coagulation in Healthy Middle-aged Men. Thromb Haemost 2018. [DOI: 10.1055/s-0038-1653729] [Citation(s) in RCA: 53] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
SummaryEffects of the quality and the time of venepuncture on factor VII coagulant activity (VIIC) and the concentrations of fibrinogen, prothrombin fragment 1 + 2 (F1 + 2) and fibrinopeptide A (FPA) were sought in 2665 men, of whom 2334 were re-examined after about one year. Venepunctures were categorised as satisfactory, not fully satisfactory or unsatisfactory according to pre-defined criteria. Neither the quality nor timing of the venepuncture influenced VIICor fibrinogen concentration. However, at baseline and re-examination F1 + 2and FPA were increased on average by about 9% and 45% respectively when venepunctures were not fully satisfactory, and by about 11% and 100% when unsatisfactory. Plasma collected after 1500 h had slightly but significantly lower levels of F1 + 2and FPA than samples taken earlier, possibly due to circadian rhythm. The results emphasise the need for careful surveillance of the venepuncture procedure and the value of FPA when using F1+ 2as a marker of risk of thrombosis.
Collapse
|
13
|
Re: "Harmonizing the Nomenclature for Therapeutic Aerosol Particle Size: A Proposal" by Hillyer et al. (J Aerosol Med Pulm Drug Deliv. 2018 [31(2):111-113]; DOI: 10/1089/jamp.2017.1396). J Aerosol Med Pulm Drug Deliv 2018; 31:266-268. [PMID: 29979636 DOI: 10.1089/jamp.2018.1479] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
14
|
Discriminating Ability of Abbreviated Impactor Measurement Approach (AIM) to Detect Changes in Mass Median Aerodynamic Diameter (MMAD) of an Albuterol/Salbutamol pMDI Aerosol. AAPS PharmSciTech 2017; 18:3296-3306. [PMID: 28589305 DOI: 10.1208/s12249-017-0814-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2017] [Accepted: 05/22/2017] [Indexed: 11/30/2022] Open
Abstract
This article reports on results from a two-lab, multiple impactor experiment evaluating the abbreviated impactor measurement (AIM) concept, conducted by the Cascade Impaction Working Group of the International Pharmaceutical Aerosol Consortium on Regulation and Science (IPAC-RS). The goal of this experiment was to expand understanding of the performance of an AIM-type apparatus based on the Andersen eight-stage non-viable cascade impactor (ACI) for the assessment of inhalation aerosols and sprays, compared with the full-resolution version of that impactor described in the pharmacopeial compendia. The experiment was conducted at two centers with a representative commercially available pressurized metered dose inhaler (pMDI) containing albuterol (salbutamol) as active pharmaceutical ingredient (API). Metrics of interest were total mass (TM) emitted from the inhaler, impactor-sized mass (ISM), as well as the ratio of large particle mass (LPM) to small particle mass (SPM). ISM and the LPM/SPM ratio together comprise the efficient data analysis (EDA) metrics. The results of the comparison demonstrated that in this study, the AIM approach had adequate discrimination to detect changes in the mass median aerodynamic diameter (MMAD) of the ACI-sampled aerodynamic particle size distribution (APSD), and therefore could be employed for routine product quality control (QC). As with any test method considered for inclusion in a regulatory filing, the transition from an ACI (used in development) to an appropriate AIM/EDA methodology (used in QC) should be evaluated and supported by data on a product-by-product basis.
Collapse
|
15
|
Development and Evaluation of a Family of Human Face and Upper Airway Models for the Laboratory Testing of Orally Inhaled Products. AAPS PharmSciTech 2017; 18:3182-3197. [PMID: 28536796 DOI: 10.1208/s12249-017-0802-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2017] [Accepted: 05/03/2017] [Indexed: 11/30/2022] Open
Abstract
Many orally inhaled products are supplied with a facemask instead of a mouthpiece, enabling aerosolized medication to be transferred from the inhaler to the lungs when the user lacks the capability to use a mouthpiece. Until recently, laboratory evaluation of an orally inhaled product-facemask was frequently undertaken by removing the facemask, treating the facemask adapter as being equivalent to a mouthpiece. Measurements of delivered drug mass were therefore subject to bias arising from the absence of dead volume, had the facemask been present. We have described the development of the Aerosol Delivery to an Anatomic Model (ADAM) infant, small child, and adult faces and upper airways, and their subsequent evaluation. Each model possesses physical features of appropriate size, and the soft tissues are also simulated. Rudimentary underlying bony structure is also present, because its purpose is only to provide support, enabling the mechanical response of the facial soft tissues when a facemask is applied to be realized. A realistic upper airway (nasopharynx for the infant model, naso- and oropharynx for the child and oropharynx for the adult models) is also incorporated, so that each model can be used to determine the mass of inhaled medication likely to penetrate as far as the lungs where therapy is intended to be applied. Measurements of the mass of pressurized metered-dose inhaler-delivered salbutamol at a filter distal to the upper airway of each model, simulating age-appropriate tidal breathing, were remarkably consistent, almost all being in the range 0.3 to 1.0 μg/kg across the model age ranges, when expressed as a fraction of body weight.
Collapse
|
16
|
Remarks on the article "Effect of maximum inhalation flow and inhaled volume on formoterol drug deposition in-vitro from an Easyhaler dry-powder inhaler" by Abadelah, et al., volume 104, page 180-87 (2017). Eur J Pharm Sci 2017; 109:144-145. [PMID: 28826676 DOI: 10.1016/j.ejps.2017.08.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2017] [Revised: 08/01/2017] [Accepted: 08/02/2017] [Indexed: 11/28/2022]
|
17
|
|
18
|
A Multi-laboratory in Vitro Study to Compare Data from Abbreviated and Pharmacopeial Impactor Measurements for Orally Inhaled Products: a Report of the European Aerosol Group (EPAG). AAPS PharmSciTech 2016; 17:1383-1392. [PMID: 26762338 DOI: 10.1208/s12249-015-0476-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2015] [Accepted: 12/21/2015] [Indexed: 11/30/2022] Open
Abstract
Fine particle dose (FPD) is a critical quality attribute for orally inhaled products (OIPs). The abbreviated impactor measurement (AIM) concept simplifies its measurement, provided there is a validated understanding of the relationship with the full resolution pharmacopoeial impactor (PIM) data for a given product. This multi-center study compared fine particle dose determined using AIM and PIM for five dry powder inhaler (DPIs) and two pressurized metered-dose inhaler (pMDI) products, one of which included a valved holding chamber (VHC). Reference measurements of FPDPIM were made by each organization using either the full-resolution Andersen 8-stage non-viable impactor (ACI) or Next Generation Impactor (NGI). FPDAIM was determined for the same OIP(s) with their choice of abbreviated impactor (fast screening impactor (FSI), fast screening Andersen (FSA), or reduced NGI (rNGI)). Each organization used its validated assay method(s) for the active pharmaceutical ingredient(s) (APIs) involved. Ten replicate measurements were made by each procedure. The upper size limit for FPDAIM varied from 4.4 to 5.0 μm aerodynamic diameter, depending upon flow rate and AIM apparatus; the corresponding size limit for FPDPIM was fixed at 5 μm in accordance with the European Pharmacopoeia. The 90% confidence interval for the ratio [FPDAIM/FPDPIM], expressed as a percentage, was contained in the predetermined 85-118% acceptance interval for nine of the ten comparisons of FPD. The average value of this ratio was 105% across all OIPs and apparatuses. The findings from this investigation support the equivalence of AIM and PIM for determination of FPD across a wide range of OIP platforms and measurement techniques.
Collapse
|
19
|
|
20
|
|
21
|
Clinically Relevant In Vitro Testing of Orally Inhaled Products-Bridging the Gap Between the Lab and the Patient. AAPS PharmSciTech 2016; 17:787-804. [PMID: 27173990 DOI: 10.1208/s12249-016-0543-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2016] [Accepted: 04/26/2016] [Indexed: 11/30/2022] Open
Abstract
Current pharmacopeial methods for in vitro orally inhaled product (OIP) performance testing were developed primarily to support requirements for drug product registration and quality control. In addition, separate clinical studies are undertaken in order to quantify safety and efficacy in the hands of the patient. However, both laboratory and clinical studies are time-consuming and expensive and generally do not investigate either the effects of misuse or the severity of the respiratory disease being treated. The following modifications to laboratory evaluation methodologies can be incorporated without difficulty to provide a better linkage from in vitro testing to clinical reality: (1) examine all types of OIP with patient-representative breathing profiles which represent normal inhaler operation in accordance with the instructions for use (IFU); (2) evaluate OIP misuse, prioritizing the importance of such testing on the basis of (a) probability of occurrence and (b) consequential impact in terms of drug delivery in accordance with the label claim; and (3) use age-appropriate patient-simulated face and upper airway models for the evaluation of OIPs with a facemask. Although it is not necessarily foreseen that these suggestions would form part of future routine quality control testing of inhalers, they should provide a closer approximation to the clinical setting and therefore be useful in the preparation for in vivo studies and in improving guidance for correct use.
Collapse
|
22
|
Developing ways to evaluate in the laboratory how inhalation devices will be used by patients and care-givers: the need for clinically appropriate testing. AAPS PharmSciTech 2014; 15:1275-91. [PMID: 24889732 DOI: 10.1208/s12249-014-0145-4] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2014] [Accepted: 05/07/2014] [Indexed: 11/30/2022] Open
Abstract
The design of methods in the pharmaceutical compendia for the laboratory-based evaluation of orally inhaled product (OIP) performance is intentionally aimed for simplicity and robustness in order to achieve the high degree of accuracy and precision required for the assurance of product quality in a regulated environment. Consequently, performance of the inhaler when used or even misused by the patient or care-giver has often not been assessed. Indeed, patient-use-based methodology has been developed in a somewhat piecemeal basis when a need has been perceived by the developing organization. There is, therefore, a lack of in-use test standardization across OIP platforms, and often important details have remained undisclosed beyond the sponsoring organization. The advent of international standards, such as ISO 20072:2009, that focus specifically on the OIP development process, together with the need to make these drug delivery devices more patient-friendly as an aid to improving compliance, is necessitating that clinically appropriate test procedures be standardized at the OIP class level. It is also important that their capabilities and limitations are well understood by stakeholders involved in the process. This article outlines how this process might take place, drawing on current examples in which significant advances in methodology have been achieved. Ideally, it is hoped that such procedures, once appropriately validated, might eventually become incorporated into the pharmacopeial literature as a resource for future inhaler developers, regulatory agencies, and clinicians seeking to understand how these devices will perform in use to augment ongoing product quality testing which is adequately served by existing methods.
Collapse
|
23
|
Investigation of dry powder inhaler (DPI) resistance and aerosol dispersion timing on emitted aerosol aerodynamic particle sizing by multistage cascade impactor when sampled volume is reduced from compendial value of 4 L. AAPS PharmSciTech 2014; 15:1126-37. [PMID: 24871551 DOI: 10.1208/s12249-014-0111-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2013] [Accepted: 03/13/2014] [Indexed: 11/30/2022] Open
Abstract
Compendial methods determining dry powder inhaler (DPI)-emitted aerosol aerodynamic particle size distribution (APSD) collect a 4-L air sample containing the aerosol bolus, where the flow, which propagates through the cascade impactor (CI) measurement system from the vacuum source, is used to actuate the inhaler. A previous article described outcomes with two CIs (Andersen eight-stage cascade impactor (ACI) and Next-Generation Pharmaceutical Impactor (NGI)) when the air sample volume was ≤4 L with moderate-resistance DPIs. This article extends that work, examining the hypothesis that DPI flow resistance may be a factor in determining outcomes. APSD measurements were made using the same CI systems with inhalers representing low and high flow resistance extremes (Cyclohaler® and HandiHaler® DPIs, respectively). The ratio of sample volume to internal dead space (normalized volume (V*)) was varied from 0.25 to 1.98 (NGI) and from 0.43 to 3.46 (ACI). Inhaler resistance was a contributing factor to the rate of bolus transfer; the higher resistance DPI completing bolus relocation to the NGI pre-separator via the inlet when V* was as small as 0.25, whereas only ca. 50% of the bolus mass was collected at this condition with the Cyclohaler® DPI. Size fractionation of the bolus from either DPI was completed within the ACI at smaller values of V* than within the NGI. Bolus transfer from the Cyclohaler® capsule and from the HandiHaler® to the ACI system were unaffected by the different flow rise time observed in the two different flow controller systems, and the effects the ACI-based on APSD measurements were marginal.
Collapse
|
24
|
Comments Regarding the Article: "In Vitro Comparison of the Effect of Inhalation Inhalation Delay and Flow Rate on the Emitted Dose from Three Valved Holding Chambers". J Aerosol Med Pulm Drug Deliv 2014:jamp.2014.1135. [PMID: 25259649 DOI: 10.1089/jamp.2014.1135] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
25
|
Considerations for Designing In Vitro Bioequivalence (IVBE) Studies for Pressurized Metered Dose Inhalers (pMDIs) with Spacer or Valved Holding Chamber (S/VHC) Add-on Devices. J Aerosol Med Pulm Drug Deliv 2014; 28:156-81. [PMID: 25089555 DOI: 10.1089/jamp.2014.1150] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND The choice of analytical test methods and associated statistical considerations are considered for the laboratory testing of pressurized metered dose inhaler-spacer/valved holding chamber (pMDI-S/VHC) combinations for in vitro bioequivalence (IVBE). METHODS Four scenarios are presented for comparing TEST ("second entry" or "generic") versus REF ("innovator"): (1) innovator and second entry product pMDI alone without any S/VHC (baseline comparison); (2) innovator and second entry pMDI product with the same S/VHC; (3) innovator pMDI product with existing S/VHC and second entry product with a different S/VHC; and (4) introduction of a second, different S/VHC to be used with a given innovator pMDI product. The following aspects should be reviewed in the preparatory stage of designing experiments to establish IVBE: (a) the inclusion of delayed inhalation; (b) the utilization of age-appropriate flow rates; and (c) the use of anatomically appropriate face models for evaluation of devices with a facemask. Statistical considerations that fit in with such experimental methods include: selection of pMDI batches and S/VHC lots; choice of sample size and acceptance criteria; bracketing or worst case approaches; and balanced/paired designs. A stepwise approach for selection of impactor stage groupings is presented, and an approach to determine realistic acceptance criteria based on REF product characteristics is suggested. RESULTS An example of an efficient statistical design of experiment is provided for each scenario, together with alternate approaches for calculation of confidence intervals for the mean TEST/REF relationship. It is important to appreciate that the optimal design depends on balancing numerous considerations and will thus likely differ from case to case; hence, the designs presented here should be seen as illustrations rather than the only option available. More effective approaches may be found that suit a particular case at hand. CONCLUSIONS The information provided will assist in developing correlations in support of IVBE for these add-on devices.
Collapse
|
26
|
β-TrCP dependency of HIV-1 Vpu-induced downregulation of CD4 and BST-2/tetherin. Curr HIV Res 2013; 10:307-14. [PMID: 22524179 DOI: 10.2174/157016212800792441] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2012] [Revised: 03/06/2012] [Accepted: 03/14/2012] [Indexed: 11/22/2022]
Abstract
During evolution, pathogens have evolved strategies to counteract key cellular restriction mechanisms in order to efficiently invade target cells and fulfill essential steps of their replication cycle. Human Immunodeficiency Virus-1 and some Simian counterparts express a small multifunctional protein, Vpu, which influences viral replication. By acting as a multifunctional adapter, Vpu enhances viral particle release and infectivity. Therefore Vpu, an accessory protein, contributes to pathogenesis while avoiding superinfection. These effects rely mainly on the ability of Vpu to target the host proteins CD4 and BST-2/tetherin. Indeed, Vpu downregulates the cell surface expression of these receptors and subsequently induces their proteolysis via a mechanism involving a β -TrCP-containing E3 ubiquitin ligase complex. In this review, we will detail recent research aimed at elucidating the mechanism of Vpu-mediated CD4 and BST-2/tetherin downregulation and degradation as well as their subsequent consequences on viral pathogenesis.
Collapse
|
27
|
Comparison of ISO standards for device performance; 20072 and 27427: a critical appraisal. J Aerosol Med Pulm Drug Deliv 2013; 25:209-16. [PMID: 22857272 DOI: 10.1089/jamp.2011.0927] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Two separate international standards, ISO 20072:2009 and ISO 27427:2010, have recently been published that relate to the development and performance testing of oral inhaled products (OIPs). The scope of ISO 20072 encompasses all OIP forms except nebulizing systems, whereas ISO 27427 was developed specifically for this class of OIP. Compliance with these standards will likely be necessary for manufacturers seeking approval to market inhaler devices in the European Union (EU). Their adoption in the United States may take a considerable time, but the FDA has expressed support in general terms for the ISO process. Key aspects of both standards that are very different in style and content are identified and discussed from the perspective of a potential user. In the approach adopted by ISO 20072, a formalized risk assessment is undertaken as a key part of design verification, in order to develop the Device Functionality Profile (DFP) of the device. The DFP is subsequently verified by the System Verification Test (SVT), in which pharmacopeial test methods are used to evaluate in vitro performance of the device with a chosen drug product in a statistically robust manner. On the other hand, ISO 27427 adopts a more prescriptive approach that involves performance verification of the finished nebulizing system using 1% w/v salbutamol as the test formulation. Although ISO 27427 is currently undergoing revision, at present it is unclear whether the changes that are made will significantly alter its fundamentally different approach to device performance verification. A strong case can be made for a single OIP-wide ISO standard, based on the principles developed in ISO 20072 and that makes use of the well-understood and validated in vitro test procedures that are available or will shortly be available in the case of nebulizing systems, in the United States and European pharmacopeias.
Collapse
|
28
|
Effect of sampling volume on dry powder inhaler (DPI)-emitted aerosol aerodynamic particle size distributions (APSDs) measured by the Next-Generation Pharmaceutical Impactor (NGI) and the Andersen eight-stage cascade impactor (ACI). AAPS PharmSciTech 2012; 13:875-82. [PMID: 22678745 DOI: 10.1208/s12249-012-9797-0] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2011] [Accepted: 04/20/2012] [Indexed: 11/30/2022] Open
Abstract
Current pharmacopeial methods for testing dry powder inhalers (DPIs) require that 4.0 L be drawn through the inhaler to quantify aerodynamic particle size distribution of "inhaled" particles. This volume comfortably exceeds the internal dead volume of the Andersen eight-stage cascade impactor (ACI) and Next Generation pharmaceutical Impactor (NGI) as designated multistage cascade impactors. Two DPIs, the second (DPI-B) having similar resistance than the first (DPI-A) were used to evaluate ACI and NGI performance at 60 L/min following the methodology described in the European and United States Pharmacopeias. At sampling times ≥2 s (equivalent to volumes ≥2.0 L), both impactors provided consistent measures of therapeutically important fine particle mass (FPM) from both DPIs, independent of sample duration. At shorter sample times, FPM decreased substantially with the NGI, indicative of incomplete aerosol bolus transfer through the system whose dead space was 2.025 L. However, the ACI provided consistent measures of both variables across the range of sampled volumes evaluated, even when this volume was less than 50% of its internal dead space of 1.155 L. Such behavior may be indicative of maldistribution of the flow profile from the relatively narrow exit of the induction port to the uppermost stage of the impactor at start-up. An explanation of the ACI anomalous behavior from first principles requires resolution of the rapidly changing unsteady flow and pressure conditions at start up, and is the subject of ongoing research by the European Pharmaceutical Aerosol Group. Meanwhile, these experimental findings are provided to advocate a prudent approach by retaining the current pharmacopeial methodology.
Collapse
|
29
|
Abstract
BACKGROUND There is increasing evidence of significant and dynamic systemic activation and upregulation of complement in multiple sclerosis (MS), which may contribute to disease pathogenesis. OBJECTIVE We aimed to investigate the pathological role of complement in MS and the potential role for complement profiling as a biomarker of MS disease state. METHODS Key components of the classical, alternative and terminal pathways of complement were measured in plasma and cerebrospinal fluid (CSF) of patients with MS in different clinical phases of disease and in matched controls. RESULTS Increased plasma levels of C3 (p<0.003), C4 (p<0.001), C4a (p<0.001), C1 inhibitor (p<0.001), and factor H (p<0.001), and reduced levels of C9 (p<0.001) were observed in MS patients compared with controls. Combined profiling of these analytes produced a statistical model with a predictive value of 97% for MS and 73% for clinical relapse when combined with selected demographic data. CSF-plasma correlations suggested that source of synthesis of these components was both systemic and central. CONCLUSION These data provide further evidence of alterations in both local and systemic expression and activation of complement in MS and suggest that complement profiling may be informative as a biomarker of MS disease, although further work is needed to determine its use in distinguishing MS from its differential.
Collapse
|
30
|
Improving the odds that patients and caregivers will use inhalers correctly: a manufacturer's response. PRIMARY CARE RESPIRATORY JOURNAL : JOURNAL OF THE GENERAL PRACTICE AIRWAYS GROUP 2011; 20:219-20. [PMID: 21311840 DOI: 10.4104/pcrj.2011.00009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
31
|
NOTES ON CLINICAL TRIALS WITH MARMOREK'S ANTITUBERCULOUS SERUM. BRITISH MEDICAL JOURNAL 2011; 1:299. [PMID: 20766004 DOI: 10.1136/bmj.1.2667.299] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
32
|
Relative precision of inhaler aerodynamic particle size distribution (APSD) metrics by full resolution and abbreviated andersen cascade impactors (ACIs): part 2--investigation of bias in extra-fine mass fraction with AIM-HRT impactor. AAPS PharmSciTech 2010; 11:1115-8. [PMID: 20623212 DOI: 10.1208/s12249-010-9473-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2010] [Accepted: 06/11/2010] [Indexed: 11/30/2022] Open
Abstract
The purpose of this study was to resolve an anomalously high measure of extra-fine particle fraction (EPF) determined by the abbreviated cascade impactor possibly relevant for human respiratory tract (AIM-HRT) in the experiment described in Part 1 of this two-part series, in which the relative precision of abbreviated impactors was evaluated in comparison with a full resolution Andersen eight-stage cascade impactor (ACI). Evidence that the surface coating used to mitigate particle bounce was laterally displaced by the flow emerging from the jets of the lower stage was apparent upon microscopic examination of the associated collection plate of the AIM-HRT impactor whose cut point size defines EPF. A filter soaked in surfactant was floated on top of this collection plate, and further measurements were made using the same pressurized metered-dose inhaler-based formulation and following the same procedure as in Part 1. Measures of EPF, fine particle, and coarse particle fractions were comparable with those obtained with the ACI, indicating that the cause of the bias had been identified and removed. When working with abbreviated impactors, this precaution is advised whenever there is evidence that surface coating displacement has occurred, a task that can be readily accomplished by microscopic inspection of all collection plates after allowing the impactor to sample ambient air for a few minutes.
Collapse
|
33
|
Relative precision of inhaler aerodynamic particle size distribution (APSD) metrics by full resolution and abbreviated andersen cascade impactors (ACIs): part 1. AAPS PharmSciTech 2010; 11:843-51. [PMID: 20480271 DOI: 10.1208/s12249-010-9452-6] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2009] [Accepted: 04/27/2010] [Indexed: 11/30/2022] Open
Abstract
The purpose of this study was to compare relative precision of two different abbreviated impactor measurement (AIM) systems and a traditional multi-stage cascade impactor (CI). The experimental design was chosen to provide separate estimates of variability for each impactor type. Full-resolution CIs are useful for characterizing the aerosol aerodynamic particle size distribution of orally inhaled products during development but are too cumbersome, time-consuming, and resource-intensive for other applications, such as routine quality control (QC). This article presents a proof-of-concept experiment, where two AIM systems configured to provide metrics pertinent to QC (QC-system) and human respiratory tract (HRT-system) were evaluated using a hydrofluoroalkane-albuterol pressurized metered dose inhaler. The Andersen eight-stage CI (ACI) served as the benchmark apparatus. The statistical design allowed estimation of precision with each CI configuration. Apart from one source of systematic error affecting extra-fine particle fraction from the HRT-system, no other bias was detected with either abbreviated system. The observed bias was shown to be caused by particle bounce following the displacement of surfactant by the shear force of the airflow diverging above the collection plate of the second impaction stage. A procedure was subsequently developed that eliminated this source of error, as described in the second article of this series (submitted to AAPS PharmSciTech). Measurements obtained with both abbreviated impactors were very similar in precision to the ACI for all measures of in vitro performance evaluated. Such abbreviated impactors can therefore be substituted for the ACI in certain situations, such as inhaler QC or add-on device testing.
Collapse
|
34
|
A novel, versatile valved holding chamber for delivering inhaled medications to neonates and small children: laboratory simulation of delivery options. Respir Care 2010; 55:419-426. [PMID: 20406509] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
BACKGROUND Delivery of bronchodilator to infants and small children from a pressurized metered-dose inhaler with valved holding chamber (pMDI-VHC) is limited by airway narrowness, short respiratory cycle time, and small tidal volume (V(T)). There is a need for a versatile, efficient VHC, given the variety of treatment modalities. METHODS We tested the AeroChamber Mini VHC (the internal geometry of which is optimized for aerosol delivery, and which accepts a pMDI canister that has a dose counter) in experiments to determine differences in the delivery of hydrofluoroalkane-propelled albuterol (90 microg/actuation) during: mechanical ventilation via endotracheal tube (ETT); manual resuscitation via ETT; and spontaneous breathing via face mask. We tested 5 units of the AeroChamber Mini VHC per test. We simulated the tidal breathing of a premature neonate (V(T) 6 mL), a term neonate (V(T) 20 mL), and a child approximately 2 years old (V(T) 60 mL). We collected the aerosol on an electret filter and quantitatively assayed for albuterol. RESULTS The total emitted mass of albuterol per actuation that exited the VHC was marginally greater during spontaneous breathing (12.1 +/- 1.8 microg) than during manual resuscitation (10.0 +/- 1.1 microg) (P = .046). Albuterol delivery via mechanical ventilation, though comparable with the premature-neonate model (3.3 +/- 1.2 microg), the term-neonate model (3.8 +/- 2.1 microg), and the 2-y-old-child model (4.2 +/- 2.3 microg) (P = .63), was significantly lower than in the spontaneous-breathing and manual-resuscitation models (P < .001). In the neonatal models the total emitted mass was similar with the spontaneous-breathing model (6.0 +/- 1.0 microg with the premature-neonate model, 10.5 +/- 0.7 microg with the term-neonate model) and the manual-resuscitation model (5.5 +/- 0.3 microg premature-neonate model, 10.7 +/- 0.9 microg term-neonate model) (P > or = .46 via one-way analysis of variance). CONCLUSION The reduced delivery of albuterol during mechanical ventilation (compared to during spontaneous breathing and manual resuscitation via ETT) was probably associated with the saturated atmosphere in the breathing circuit (37 degrees C, relative humidity > 99%), compared to the ambient air (22 +/- 1 degrees C, 44 +/- 7% relative humidity). The AeroChamber Mini VHC may provide a versatile alternative to VHCs that are designed exclusively for one aerosol treatment modality.
Collapse
|
35
|
Improved quality control metrics for cascade impaction measurements of orally inhaled drug products (OIPs). AAPS PharmSciTech 2009; 10:1276-85. [PMID: 19882251 DOI: 10.1208/s12249-009-9312-4] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2009] [Accepted: 09/18/2009] [Indexed: 11/30/2022] Open
Abstract
This study of aerodynamic mass-weighted particle size distribution (APSD) data from orally inhaled products (OIPs) investigated whether a set of simpler (than currently used) metrics may be adequate to detect changes in APSD for quality control (QC) purposes. A range of OIPs was examined, and correlations between mass median aerodynamic diameter and the ratio of large particle mass (LPM) to small particle mass (SPM) were calculated. For an Andersen cascade impactor, the LPM combines the mass associated with particle sizes from impactor stage 1 to a product-specific boundary size; SPM combines the mass of particles from that boundary through to terminal filter. The LPM-SPM boundary should be chosen during development based on the full-resolution impactor results so as to maximize the sensitivity of the LPM/SPM ratio to meaningful changes in quality. The LPM/SPM ratio along with the impactor-sized mass (ISM) are by themselves sufficient to detect changes in central tendency and area under the APSD curve, which are key in vitro quality attributes for OIPs. Compared to stage groupings, this two-metric approach provides better intrinsic precision, in part due to having adequate mass and consequently better ability to detect changes in APSD and ISM, suggesting that this approach should be a preferred QC tool. Another advantage is the possibility to obtain these metrics from the abbreviated impactor measurements (AIM) rather than from full-resolution multistage impactors. Although the boundary is product specific, the testing could be accomplished with a basic AIM system which can meet the needs of most or all OIPs.
Collapse
|
36
|
Oral inhalation therapy: meeting the challenge of developing more patient-appropriate devices. Expert Rev Med Devices 2009; 6:147-55. [PMID: 19298162 DOI: 10.1586/17434440.6.2.147] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Although oral inhalers have been mass produced for more than 50 years, there is a large body of literature in which evidence has been provided that patients either misuse their inhalers inadvertently or deliberately, thereby reducing their intended efficacy or, in the worst cases, rendering them altogether ineffective. In general, inhalers are becoming increasingly complicated with the incorporation of add-on devices, miniaturized electronics and ever more complex mechanical systems that aid aerosol delivery to the lower respiratory tract and, at the same time provide user feedback. However, these benefits often come at a significant cost, and there are signs that increasing attention will need to be given to the cost-benefit equation in the future. This review explores the development of pressurized metered-dose inhalers, dry powder inhalers and devices for liquid-droplet dispersal and inhalation from the perspective of the patient, by focusing on aspects that improve user interaction. These include designed-in features, such as breath-enhanced or breath-actuated operation that interact with the breathing pattern of the user, as well as more direct feedback aids that confirm, to the patient or healthcare provider that the dose has been delivered and that the patient has inhaled.
Collapse
|
37
|
IN VITRO PERFORMANCE COMPARISON OF A BREATH-ACTUATED NEBULIZER FOR THE DELIVERY OF ALBUTEROL OPERATED WITH COMPRESSED HELIOX OR AIR. Chest 2008. [DOI: 10.1378/chest.134.4_meetingabstracts.p93002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
|
38
|
Appropriate face models for evaluating drug delivery in the laboratory: the current situation and prospects for future advances. J Aerosol Med Pulm Drug Deliv 2008; 21:97-112. [PMID: 18518836 DOI: 10.1089/jamp.2007.0641] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
The laboratory evaluation of inhalers with facemasks for patient interface is so complex that testing without a facemask is generally undertaken, a practice that has been advocated in one standard. However, the facemask itself can profoundly influence medication delivery. A systematic review of the literature was undertaken to establish the development history of face models for the evaluation of facemasks used with inhalers and accessories. Initial attempts to simulate the facemask-face boundary employed a circular, firm rubber flange plate upon which the facemask was located. However, such models did not represent dead volume accurately, which is particularly important when assessing infant use. Subsequent developments included the creation of more realistic facial features, enabling the aerosol leaving the inhaler to be quantified at the facemask. In one instance (SAINT model), an anatomically correct nasopharyngeal cavity has been combined with a model face, enabling assessment of medication delivery to be extended to the lower respiratory tract. However, it is necessary either to apply sealants or to compress the facemask beyond normal to eliminate leakage with the rigid facial structure that is incomplete above the bridge of the nose. An oral-breathing infant full-face model (ADAM) intended to be used to quantify emitted mass at the patient interface incorporates flexible facial features to overcome this limitation. There is a need to extend the flexible face approach to other models that may be developed in the future for testing facemasks, whether or not they incorporate anatomically correct realizations of the upper respiratory tract.
Collapse
|
39
|
Valved holding chambers (VHCs) for use with pressurised metered-dose inhalers (pMDIs): a review of causes of inconsistent medication delivery. PRIMARY CARE RESPIRATORY JOURNAL : JOURNAL OF THE GENERAL PRACTICE AIRWAYS GROUP 2007; 16:207-14. [PMID: 17625786 PMCID: PMC6634215 DOI: 10.3132/pcrj.2007.00034] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Valved holding chambers (VHCs) are prescribed with pressurised metered dose inhalers (pMDIs) to improve medication delivery for the treatment of respiratory diseases because they reduce the need for the patient to co-ordinate inhaler actuation with the onset of inhalation. Although mechanically robust and clinically effective if properly designed and pre-conditioned, there are several causes of inconsistent medication delivery if this is not the case. These include: electrostatic charge; incorrect operation of inhalation and exhalation valves; and the fit of the facemask - where present - to the face. In addition, behavioral factors, such as not following patient instructions for use and maintenance, and imperfect breathing technique, amplify overall variability. Aids such as valve movement indicators that provide patient feedback are helpful in order to minimise these factors. METHODS This article reviews recent literature concerning the causes of inconsistent drug delivery and the improvements that have been made by manufacturers to VHC devices, and assesses the clinical implications. The attributes of a well-designed VHC are summarised.
Collapse
|
40
|
Design of Facemasks for Delivery of Aerosol-Based Medication via Pressurized Metered Dose Inhaler with Valved Holding Chamber: Key Issues that Affect Performance. ACTA ACUST UNITED AC 2007; 20 Suppl 1:S29-42; discussion S42-5. [PMID: 17411403 DOI: 10.1089/jam.2007.0571] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Valved holding chambers (VHCs) are widely prescribed for use with pressurized metered dose inhalers (pMDIs) for the treatment of respiratory disease by aerosol therapy. The facemask is the preferred patient interface for use by infants and small children, as well as by geriatric patients, due primarily to poor coordination skills. However, care is required in the design of the facemask-VHC system to optimize the delivery of medication. In particular, it is essential to achieve an effective mask-to-face seal and to minimize the volume of dead space. It is also important to ensure that the fit of the facemask is comfortable to the patient when applied with sufficient force to create a seal. We review each of these design principles and their application in the evolution of a range of VHCs from the same family of devices during the past fifteen years. We also examine the various methods available for evaluating VHC-facemasks as a system, recommending where future work might be directed.
Collapse
|
41
|
Electrostatics and inhaled medications: influence on delivery via pressurized metered-dose inhalers and add-on devices. Respir Care 2007; 52:283-300. [PMID: 17328827] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
The movement of inhaler-generated aerosols is significantly influenced by electrostatic charge on the particles and on adjacent surfaces. Particle charging arises in the aerosol formation process. Since almost all inhalers contain nonconducting components, these surfaces can also acquire charge during manufacture and use. Spacers and valved holding chambers used with pressurized metered-dose inhalers to treat obstructive lung diseases are particularly prone to this behavior, which increases variability in the amount of medication available for inhalation, and this is exacerbated by low ambient humidity. This may result in inconsistent medication delivery. Conditioning the device by washing it with a conductive surfactant (detergent) or using devices made of charge-dissipative/conducting materials can mitigate electrostatic charge. This review discusses sources of electrostatic charge, the processes that influence aerosol behavior, methods to mitigate electrostatic charge, and potential clinical implications.
Collapse
|
42
|
Laser Diffractometry as a Technique for the Rapid Assessment of Aerosol Particle Size from Inhalers. ACTA ACUST UNITED AC 2006; 19:409-33. [PMID: 17196072 DOI: 10.1089/jam.2006.19.409] [Citation(s) in RCA: 81] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The rapid assessment of aerosols produced by medicinal inhalers is highly desirable from several standpoints, including the assurance of product quality, the development of new delivery systems, and the need to meet an increasing requirement by regulatory bodies for reliable in vitro performance data. Particle size analysis has traditionally been undertaken by cascade impactor on account of the direct assessment of active pharmaceutical ingredient(s) (APIs) that is possible by this method. However, laser diffractometry is less labor-intensive, more rapid, and can be a less invasive procedure. The technique provides meaningful results; as long as precautions are taken to validate that the measurements are an accurate reflection of the distribution of API mass as a function of particle or droplet size. We begin the review by examining the underlying theory of the laser diffraction method. After a brief description of current laser diffractometers used in inhaler measurements, we continue by examining the range of applications by inhaler class. We then examine the basis upon which inhaler measurements made by laser-diffractometry can be compared with equivalent particle size distribution data from compendial techniques. We conclude the assessment of the technique by developing guidelines for its valid application as a component of the range of in vitro methods that are available for inhaler performance assessment.
Collapse
|
43
|
Laser diffractometry and cascade impaction for nebulizer product characterization. PHARMEUROPA SCIENTIFIC NOTES 2006; 2006:49-52. [PMID: 17691215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
The techniques of laser diffractometry and multi-stage cascade impaction are widely used in the in vitro characterization of liquid droplet aerosols generated from nebulizing systems. This position paper is a concise summary of key aspects relating to both techniques and is intended to inform the development of the proposed general chapter 2.9.44 "Preparations for Nebulization" for the European Pharmacopeia, as well as assist in the development of a proposed International Standard (ISO 27427) for nebulizing systems.
Collapse
|
44
|
Comparison of Three Valved Holding Chambers for the Delivery of Fluticasone Propionate–HFA to an Infant Face Model. ACTA ACUST UNITED AC 2006; 19:160-7. [PMID: 16796540 DOI: 10.1089/jam.2006.19.160] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The purpose of this study was to compare three valved holding chambers (VHC) with facemasks attached. One VHC (AeroChamber Max[TM] with medium mask) was made with materials that dissipate surface electrostatic charge, and the others (OptiChamber Advantage and ProChamber[TM] with pediatric facemask) were made from non-conducting materials. The OptiChamber Advantage and ProChamber VHCs were each washed with an ionic detergent and drip dried before testing to minimize surface electrostatic charge. The AeroChamber Max VHCs were tested "out of the package" and also after wash, rinse, and drying. An infant face model incorporating an electrostatic filter in the oral cavity was connected to a breath simulator using a standard waveform for a small child. The fit of each VHC with facemask was demonstrated by agreement of inspiratory flow measurements between a pneumotachograph connected to the system with those set on the simulator. An HFA-fluticasone propionate metered dose inhaler (MDI; 125 microg/dose) was inserted into the VHC, two actuations were delivered, and the filters were subsequently assayed using high-pressure liquid chromatography (HPLC). Testing and sample assay order was randomized, and HPLC assays were undertaken blinded. Drug delivery efficiency expressed as a percentage of the total dose of fluticasone propionate (250 microg) for the AeroChamber Max VHC "out-of-the-package" was 22.0(0.7)% (mean [99% CI]) and 21.2(1.5)% when pre-washed/rinsed. Results for the pre-washed ProChamber and OptiChamber Advantage VHCs were 10.2(0.55)% and 8.8(1.9)%, respectively. The more efficient delivery of medication via VHCs made from electrostatic charge dissipative materials should be considered when choosing doses for small children.
Collapse
|
45
|
Levalbuterol aerosol delivery with a nonelectrostatic versus a nonconducting valved holding chamber. Respir Care 2006; 51:511-4. [PMID: 16638161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
BACKGROUND Hydrofluoroalkane-propelled levalbuterol (Xopenex) aerosol is a recently approved formulation for delivery via metered-dose inhaler for the treatment or prevention of bronchospasm in adults, adolescents, and children > or = 4 years of age who have reversible obstructive airway disease. Valved holding chambers (VHCs) made from conventional polymers are susceptible to accumulation of electrostatic charge, which can be minimized by prewashing with ionic detergent, but it may be desirable to be able to use the product straight from the package, without pretreatment, especially during an exacerbation. METHODS We studied the performance of the AeroChamber Plus and AeroChamber Max VHCs in delivering hydrofluoroalkane-propelled levalbuterol. Both VHCs were prewashed, rinsed, and drip-dried before testing. The AeroChamber Max is manufactured from charge-dissipative material and was therefore also evaluated without prewashing. Aerosol samples were collected at 28.3 L/min with an Andersen 8-stage cascade impactor, per the procedure specified in Chapter 601 of the United States Pharmacopeia. RESULTS The mean +/- SD fine-particle mass (mass of aerosol particles < 4.7 microm aerodynamic diameter) values were 33.5 +/- 1.4 microg and 36.3 +/- 1.1 microg with the AeroChamber Max, without and with wash/rinse pretreatment, respectively, and 28.5 +/- 2.4 microg with the prewashed AeroChamber Plus. CONCLUSIONS We think the small differences we observed are unlikely to be of clinical importance, given the inter-patient variability seen with inhaled drug delivery. The performance of the AeroChamber Max was substantially comparable whether or not it was prewashed.
Collapse
|
46
|
The importance of nonelectrostatic materials in holding chambers for delivery of hydrofluoroalkane albuterol. Respir Care 2006; 51:503-10. [PMID: 16638160] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
INTRODUCTION Electrostatic attraction of aerosolized particles to the inner walls of an aerosol holding chamber (HC) made from a nonconducting material can reduce medication delivery, particularly if there is a delay between actuation and inhalation. OBJECTIVE Compare total emitted mass and fine-particle mass (mass of particles < 4.7 microm) of hydrofluoroalkane-propelled albuterol from similar-sized HCs manufactured from conductive material (Vortex), charge-dissipative material (AeroChamber Max), and nonconductive material (OptiChamber Advantage, ProChamber, Breathrite, PocketChamber, and ACE), with and without wash/rinse pretreatment of the HC interior with ionic detergent, and with 2-s and 5-s delays between actuation and inhalation. METHODS All the HCs were evaluated (1) directly from their packaging (with no wash/rinse pretreatment) and (2) after washing with ionic detergent and rinsing and drip-drying. We used an apparatus that interfaced between the HC mouthpiece and the induction port of an 8-stage Andersen cascade impactor to simulate a poorly coordinated patient, with delays of 2 s and 5 s between actuation and inhalation/sampling, at 28.3 L/min. RESULTS With the 2-s delay, the delivered fine-particle mass per actuation, before and after (respectively) wash/rinse pretreatment was: AeroChamber Max: 23.8 +/- 4.8 microg, 21.5 +/- 3.2 microg; Vortex: 16.2 +/- 1.7 microg, 15.5 +/- 2.0 microg; OptiChamber Advantage: 2.6 +/- 1.2 microg, 6.7 +/- 2.3 microg; ProChamber: 1.6 +/- 0.4 microg, 5.1 +/- 2.5 microg; Breathrite: 2.0 +/- 0.9 microg, 3.2 +/- 1.8 microg; PocketChamber: 3.4 +/- 1.6 microg, 1.7 +/- 1.6 microg; ACE: 4.5 +/- 0.9 microg, 5.4 +/- 2.9 microg. Similar trends, but greater reduction in aerosol delivery, were observed with the 5-s delay. Significantly greater fine-particle mass was delivered from HCs made from conducting or charge-dissipative materials than from those made from nonconductive polymers, even after wash/rinse pretreatment (p < 0.01). The fine-particle mass was also significantly greater from the AeroChamber Max than from the Vortex, irrespective of wash/rinse pretreatment or delay interval (p < 0.01). CONCLUSION HCs made from electrically conductive materials emit significantly greater fine-particle mass, with either a 2-s or 5-s delay, than do HCs made from nonconducting materials, even with wash/rinse pretreatment.
Collapse
|
47
|
Trauma Management. Volume II. Urogential Trauma. Blaisdell and Trunkey. Guest Editor Jack W. McAninch. 250 × 170 mm. Pp. 125 + ix. Illustrated. 1985. Stuttgart: Georg Thieme Verlag. DM 128. Br J Surg 2005. [DOI: 10.1002/bjs.1800721232] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
48
|
|
49
|
Revised Internal Volumes of Cascade Impactors for Those Provided by Mitchell and Nagel. ACTA ACUST UNITED AC 2005; 18:364-6. [PMID: 16181010 DOI: 10.1089/jam.2005.18.364] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
50
|
Agricultural dust production in standard and conservation tillage systems in the San Joaquin Valley. JOURNAL OF ENVIRONMENTAL QUALITY 2005; 34:1260-9. [PMID: 15998847 DOI: 10.2134/jeq2003.0348] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
The negative health effects of repeated dust exposure have been well documented. In California's San Joaquin Valley, agricultural operations may contribute substantially to airborne particulates. We evaluated four management systems to assess impacts on dust production and soil properties for a cotton (Gossypium hirsutum L.)-tomato (Lycopersicon esculentum Mill.) rotation: standard tillage with (STCC) and without (STNO) cover crop, and conservation tillage with (CTCC) and without (CTNO) cover crop. Gravimetric analysis of total dust (TD, <100-mum aerodynamic diameter) and respirable dust (RD, 4-mum aerodynamic diameter) samples collected in the plume generated by field implements showed that dust concentrations for CTNO treatments were about one-third of their STNO counterparts for both cumulative TD and RD measured throughout the two-year rotation, primarily due to fewer in-field operations. The TD and RD production for STNO and STCC was comparable, whereas the CTCC system produced about twice as much TD and RD as CTNO. Energy dispersive spectroscopy (EDS) analyses showed absolute increases of 8 and 39% organic fragments in STCC and CTCC over STNO and CTNO, respectively, while organic fragments in the TD increased by 6% in both cover crop treatments. Soil C content was positively correlated with clay content and increased by an average of 0.12 and 0.07% in the cover crop and non-cover crop treatments, respectively, although soil C for each treatment showed a distinct response to a field texture gradient. While dust emissions show an immediate decrease due to fewer field operations for the conservation tillage treatments, long-term sampling is necessary to determine the effects that increased aggregation through organic matter additions may have on dust production.
Collapse
|