1
|
Effect of ethylene oxide unit number in bis-EMA on the physical properties of additive-manufactured occlusal splint material. J Prosthodont Res 2024:JPR_D_23_00203. [PMID: 38281759 DOI: 10.2186/jpr.jpr_d_23_00203] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2024]
Abstract
PURPOSE To investigate the effects of the number of ethylene oxide units in bis-EMA on the physical properties of additively manufactured occlusal splints. METHODS Seven experimental materials containing bis-EMAs with three and 10 ethylene oxide units (BE3 and BE10, respectively) were prepared at different BE10 content rates (BE10-0%, -20%, -30%, -40%, -50%, -60%, and -80%). Half the specimens of each material were aged in boiling water. Flexural strength (FS), flexural modulus (FM), fracture toughness (FT), microwear depth (MD), degree of conversion (DC), water sorption (WSP), water solubility (WSL), color difference between non-aged and aged series (ΔE), and translucency (TP) were evaluated. All the evaluated properties other than FS and MD were analyzed by 1-way ANOVA and Tukey's post hoc analysis, while FS and MD were analyzed by Kruskal-Wallis's test and Bonferroni correction (α=0.05). RESULTS BE10-80% revealed the lowest FS (P < 0.01 for BE10-0%, -20%, and -30%) and FM (P < 0.01, for all), while revealing the highest DC, WSP, WSL (P < 0.01 for all) and TP (P < 0.01 for all other than BE10-60%). BE10-50% showed the highest FT (P < 0.01 for all). BE10-50%, -60%, and -80% revealed significantly lower ΔE than others (P < 0.01) and lower MD than BE10-0% (P < 0.05). Regardless of the BE10 content, FS, FM, and FT decreased with aging. CONCLUSIONS The number of ethylene oxide units affects the physical properties of additively manufactured occlusal splints. The higher number of ethylene oxide units in bis-EMA enhanced the microwear resistance, DC, WSP, WSL, color stability, and translucency, whereas it deteriorated the FS and FM.
Collapse
|
2
|
Effects of empagliflozin on progression of chronic kidney disease: a prespecified secondary analysis from the empa-kidney trial. Lancet Diabetes Endocrinol 2024; 12:39-50. [PMID: 38061371 PMCID: PMC7615591 DOI: 10.1016/s2213-8587(23)00321-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 10/24/2023] [Accepted: 10/25/2023] [Indexed: 12/23/2023]
Abstract
BACKGROUND Sodium-glucose co-transporter-2 (SGLT2) inhibitors reduce progression of chronic kidney disease and the risk of cardiovascular morbidity and mortality in a wide range of patients. However, their effects on kidney disease progression in some patients with chronic kidney disease are unclear because few clinical kidney outcomes occurred among such patients in the completed trials. In particular, some guidelines stratify their level of recommendation about who should be treated with SGLT2 inhibitors based on diabetes status and albuminuria. We aimed to assess the effects of empagliflozin on progression of chronic kidney disease both overall and among specific types of participants in the EMPA-KIDNEY trial. METHODS EMPA-KIDNEY, a randomised, controlled, phase 3 trial, was conducted at 241 centres in eight countries (Canada, China, Germany, Italy, Japan, Malaysia, the UK, and the USA), and included individuals aged 18 years or older with an estimated glomerular filtration rate (eGFR) of 20 to less than 45 mL/min per 1·73 m2, or with an eGFR of 45 to less than 90 mL/min per 1·73 m2 with a urinary albumin-to-creatinine ratio (uACR) of 200 mg/g or higher. We explored the effects of 10 mg oral empagliflozin once daily versus placebo on the annualised rate of change in estimated glomerular filtration rate (eGFR slope), a tertiary outcome. We studied the acute slope (from randomisation to 2 months) and chronic slope (from 2 months onwards) separately, using shared parameter models to estimate the latter. Analyses were done in all randomly assigned participants by intention to treat. EMPA-KIDNEY is registered at ClinicalTrials.gov, NCT03594110. FINDINGS Between May 15, 2019, and April 16, 2021, 6609 participants were randomly assigned and then followed up for a median of 2·0 years (IQR 1·5-2·4). Prespecified subgroups of eGFR included 2282 (34·5%) participants with an eGFR of less than 30 mL/min per 1·73 m2, 2928 (44·3%) with an eGFR of 30 to less than 45 mL/min per 1·73 m2, and 1399 (21·2%) with an eGFR 45 mL/min per 1·73 m2 or higher. Prespecified subgroups of uACR included 1328 (20·1%) with a uACR of less than 30 mg/g, 1864 (28·2%) with a uACR of 30 to 300 mg/g, and 3417 (51·7%) with a uACR of more than 300 mg/g. Overall, allocation to empagliflozin caused an acute 2·12 mL/min per 1·73 m2 (95% CI 1·83-2·41) reduction in eGFR, equivalent to a 6% (5-6) dip in the first 2 months. After this, it halved the chronic slope from -2·75 to -1·37 mL/min per 1·73 m2 per year (relative difference 50%, 95% CI 42-58). The absolute and relative benefits of empagliflozin on the magnitude of the chronic slope varied significantly depending on diabetes status and baseline levels of eGFR and uACR. In particular, the absolute difference in chronic slopes was lower in patients with lower baseline uACR, but because this group progressed more slowly than those with higher uACR, this translated to a larger relative difference in chronic slopes in this group (86% [36-136] reduction in the chronic slope among those with baseline uACR <30 mg/g compared with a 29% [19-38] reduction for those with baseline uACR ≥2000 mg/g; ptrend<0·0001). INTERPRETATION Empagliflozin slowed the rate of progression of chronic kidney disease among all types of participant in the EMPA-KIDNEY trial, including those with little albuminuria. Albuminuria alone should not be used to determine whether to treat with an SGLT2 inhibitor. FUNDING Boehringer Ingelheim and Eli Lilly.
Collapse
|
3
|
Impact of primary kidney disease on the effects of empagliflozin in patients with chronic kidney disease: secondary analyses of the EMPA-KIDNEY trial. Lancet Diabetes Endocrinol 2024; 12:51-60. [PMID: 38061372 DOI: 10.1016/s2213-8587(23)00322-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Revised: 10/24/2023] [Accepted: 10/25/2023] [Indexed: 12/23/2023]
Abstract
BACKGROUND The EMPA-KIDNEY trial showed that empagliflozin reduced the risk of the primary composite outcome of kidney disease progression or cardiovascular death in patients with chronic kidney disease mainly through slowing progression. We aimed to assess how effects of empagliflozin might differ by primary kidney disease across its broad population. METHODS EMPA-KIDNEY, a randomised, controlled, phase 3 trial, was conducted at 241 centres in eight countries (Canada, China, Germany, Italy, Japan, Malaysia, the UK, and the USA). Patients were eligible if their estimated glomerular filtration rate (eGFR) was 20 to less than 45 mL/min per 1·73 m2, or 45 to less than 90 mL/min per 1·73 m2 with a urinary albumin-to-creatinine ratio (uACR) of 200 mg/g or higher at screening. They were randomly assigned (1:1) to 10 mg oral empagliflozin once daily or matching placebo. Effects on kidney disease progression (defined as a sustained ≥40% eGFR decline from randomisation, end-stage kidney disease, a sustained eGFR below 10 mL/min per 1·73 m2, or death from kidney failure) were assessed using prespecified Cox models, and eGFR slope analyses used shared parameter models. Subgroup comparisons were performed by including relevant interaction terms in models. EMPA-KIDNEY is registered with ClinicalTrials.gov, NCT03594110. FINDINGS Between May 15, 2019, and April 16, 2021, 6609 participants were randomly assigned and followed up for a median of 2·0 years (IQR 1·5-2·4). Prespecified subgroupings by primary kidney disease included 2057 (31·1%) participants with diabetic kidney disease, 1669 (25·3%) with glomerular disease, 1445 (21·9%) with hypertensive or renovascular disease, and 1438 (21·8%) with other or unknown causes. Kidney disease progression occurred in 384 (11·6%) of 3304 patients in the empagliflozin group and 504 (15·2%) of 3305 patients in the placebo group (hazard ratio 0·71 [95% CI 0·62-0·81]), with no evidence that the relative effect size varied significantly by primary kidney disease (pheterogeneity=0·62). The between-group difference in chronic eGFR slopes (ie, from 2 months to final follow-up) was 1·37 mL/min per 1·73 m2 per year (95% CI 1·16-1·59), representing a 50% (42-58) reduction in the rate of chronic eGFR decline. This relative effect of empagliflozin on chronic eGFR slope was similar in analyses by different primary kidney diseases, including in explorations by type of glomerular disease and diabetes (p values for heterogeneity all >0·1). INTERPRETATION In a broad range of patients with chronic kidney disease at risk of progression, including a wide range of non-diabetic causes of chronic kidney disease, empagliflozin reduced risk of kidney disease progression. Relative effect sizes were broadly similar irrespective of the cause of primary kidney disease, suggesting that SGLT2 inhibitors should be part of a standard of care to minimise risk of kidney failure in chronic kidney disease. FUNDING Boehringer Ingelheim, Eli Lilly, and UK Medical Research Council.
Collapse
|
4
|
Morphological Comparison of Residual Ridge in Impression for Removable Partial Denture between Digital and Conventional Techniques: A Preliminary In-Vivo Study. J Clin Med 2023; 12:7103. [PMID: 38002714 PMCID: PMC10671937 DOI: 10.3390/jcm12227103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Revised: 11/10/2023] [Accepted: 11/13/2023] [Indexed: 11/26/2023] Open
Abstract
Although digital impression using an intraoral scanner (IOS) has been applied for removable partial denture (RPD) fabrication, it is still unclear how the morphology of a residual ridge recorded by digital impression would differ from that recorded by conventional impression. This in vivo study investigated the morphological difference in the recorded residual ridge between digital and conventional impressions. Vertical and horizontal displacements (VD and HD) in residual ridges recorded by digital and conventional impressions were assessed in 22 participants (15 female; mean age 78.2 years) based on the morphology of the tissue surface of in-use RPD. Additionally, the mucosal thickness of the residual ridge was recorded using an ultrasound diagnostic device. VD and HD were compared using the Wilcoxon signed-rank test, and the correlation of mucosal thickness with VD and HD was analyzed using Spearman's ρ. The VD of digital impression was significantly greater than that of a conventional impression (p = 0.031), while no significant difference was found in HD (p = 0.322). Meanwhile, the mucosal thickness showed no significant correlation with the recorded morphology of the residual ridge, regardless of the impression techniques. It was concluded that the digital impression would result in a greater displacement in the height of the residual ridge from the morphology of in-use RPD than the conventional impression.
Collapse
|
5
|
Effect of abutment tooth location on the accuracy of digital impressions obtained using an intraoral scanner for removable partial dentures. J Prosthodont Res 2023; 67:531-538. [PMID: 36775339 DOI: 10.2186/jpr.jpr_d_22_00201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
Abstract
PURPOSE To verify the effect of abutment tooth location on the accuracy of digital impressions obtained using an intraoral scanner (IOS) for removable partial dentures (RPDs). METHODS The target abutment teeth included the left first premolar (#34), second molar (#37), and right second premolar (#45) in a mandibular Kennedy class II model and the left and right second molars (#37, #47) in a class III model. Only #37 was isolated from the remaining teeth by the mucosal area in both models. Digital impressions were obtained using a desktop scanner (reference data) and an IOS (IOS data; scanning origin #37; n=10). The general trueness based on the entire model superimposition (TG), local trueness (TL) of an individual tooth, and dimensional accuracy (coordinate and linear accuracy) of the IOS data of the target abutment teeth were compared (α=0.05). RESULTS In both models, #37 showed significantly inferior TG (P<0.01), superior TL (P<0.01), and mesial coordinate displacement (P<0.01 and P<0.05 in class II and III models, respectively). Intra-model comparisons showed that #45 in the class II model and #47 in the class III model had significantly inferior linear accuracy (P<0.05 and P<0.01, respectively) and buccal coordinate displacement (P<0.05 and P<0.01, respectively) compared with the other target teeth. CONCLUSIONS In digital impressions of RPDs, isolation of abutment teeth by mucosal areas can reduce general trueness based on the entire dental arch and mesial tooth displacement, whereas increased distance from the scanning origin can adversely affect local trueness and dimensional accuracy.
Collapse
|
6
|
Knowledge acquisition efficacy of a remote flipped classroom on learning about removable partial dentures. J Prosthodont Res 2023; 67:444-449. [PMID: 36418083 DOI: 10.2186/jpr.jpr_d_22_00147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/01/2023]
Abstract
PURPOSE Coronavirus disease 2019 has forced the use of remote education worldwide. In 2020, the authors conducted a fully digitized, remote flipped (RF) classroom focusing on removable partial dentures. This study aimed to evaluate the learning outcomes of the RF classroom and compare these with those of the on-site classroom. METHODS The fourth-year dental students in 2017-2019 attended on-site flipped classroom (OF; n=70) or on-site lecture classroom (OL; n=67), and those in 2020 (n=58) attended the RF classroom. Lecture videos and text were provided online in the OF and RF groups, while only the text was given to the OL group. Individual and group tests were conducted to assess knowledge acquisition one week after all the classes ended. A one-way analysis of variance following Tukey's test was performed to compare individual/group test scores among the OF, OL, and RF groups. Multilevel linear regression analysis was performed to identify the factors associated with an increase in each test score. RESULTS The mean individual test scores in the RF and OF groups were significantly higher than in the OL group (P<0.01). The mean group test score in the RF group was significantly higher than in the OF and OL groups (P<0.001). The multilevel analysis identified remote and flipped classroom styles in the individual test, and the remote style in the group test, as significant effective factors in learning (P<0.05). CONCLUSIONS These results suggest that the RF classroom is more effective than the on-site lecture in knowledge acquisition in undergraduate prosthodontic education.
Collapse
|
7
|
Radiographic predictive factors for 10-year survival of removable partial denture abutment teeth: Alveolar bone level and density. J Prosthodont Res 2023; 67:437-443. [PMID: 36418082 DOI: 10.2186/jpr.jpr_d_22_00034] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/01/2023]
Abstract
PURPOSE To determine postoperative periodontal and radiographic factors that predict the survival rates of abutments of removable partial dentures (RPDs). METHODS Patients who wore RPDs for > 10 years and received supportive periodontal therapy were included. Periodontal examinations and radiographic assessments were conducted on 83 abutment teeth in 35 patients at baseline, and five years after RPD insertion. In addition to conventional factors, such as tooth mobility at 5 years, radiographic factors, such as the crown-root ratio (ΔCR ratio) and gray-level changes reflecting changes in alveolar bone density (ΔABD), were evaluated. The impact of the covariables on the 10-year survival of abutment teeth was estimated using a multivariate Cox regression model, considering multicollinearity. RESULTS Patients were classified as having A2-B2 (45.7%) and B3-C2 (54.3%) tooth loss, according to the Eichner classification. A probing depth ≥ 4 mm, tooth mobility ≥ grade 1, and CR ratio ≥ 1 were found in 30.1%, 33.7%, and 51.8% of abutment teeth, respectively. The 10-year survival rate of abutment teeth was 86.7%. Multivariate analysis showed that the 10-year survival of abutment teeth was significantly associated with root canal treatment (P = 0.045, hazard ratio [HR] = 1.23), the 5-year ΔCR ratio (P = 0.022, HR = 3.20), and ΔABD on the edentulous side of the abutment teeth (P = 0.047, HR = 1.08). CONCLUSIONS In addition to root canal treatment, changes in the CR ratio and radiographic alveolar bone density at five years predicted the long-term survival rate of RPD abutments.
Collapse
|
8
|
Effect of 3D printing system and post-curing atmosphere on micro- and nano-wear of additive-manufactured occlusal splint materials. J Mech Behav Biomed Mater 2023; 142:105799. [PMID: 37028121 DOI: 10.1016/j.jmbbm.2023.105799] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Revised: 03/10/2023] [Accepted: 03/23/2023] [Indexed: 04/07/2023]
Abstract
Although additive manufacturing has been widely applied for occlusal splint (OS) fabrication, it is still unclear whether 3D printing system and post-curing atmosphere would play a role in the wear resistance of additive-manufactured OS. Therefore, the aim of this study was to evaluate the effect of 3D printing system (liquid crystal display (LCD) and digital light processing (DLP)) and post-curing atmosphere (air and nitrogen gas (N2)) on the wear resistance of hard and soft OS materials for additive-manufactured OSs (KeySplint® Hard and Soft). The evaluated properties were microwear (by two-body wear test) and nano-wear resistances (by nanoindentation wear test) as well as flexural strength and flexural modulus (by three-point bending test), surface microhardness (by Vickers hardness test), and nanoscale elastic modulus (reduced elastic modulus) and nano surface hardness (by nanoindentation test). For the hard material, the surface microhardness, microwear resistance, reduced elastic modulus, nano surface hardness, and nano-wear resistance were significantly affected by the printing system (p < 0.05), while all the evaluated properties except flexural modulus were significantly affected by the post-curing atmosphere (p < 0.05). Meanwhile, both the printing system and post-curing atmosphere significantly affected all the evaluated properties (p < 0.05). The specimens additive-manufactured by DLP printer tended to show higher wear resistance in the hard material groups and lower wear resistance in the soft material groups when compared to those by LCD printer. The post-curing at N2 atmosphere significantly enhanced the microwear resistance of hard material groups additive-manufactured by the DLP printer (p < 0.05) and soft material groups additive-manufactured by the LCD printer (p < 0.01), while it significantly enhanced the nano-wear resistance of both hard and soft material groups regardless of the printing system (p < 0.01). It can be concluded that 3D printing system and post-curing atmosphere affect the micro- and nano-wear resistance of tested additively manufactured OS materials. In addition, it can be also concluded that the optical printing system providing higher wear resistance depends on the material type, and using nitrogen gas as a protection gas during post-curing enhances the wear resistance of tested materials.
Collapse
|
9
|
Effect of splinting material type and location on resistance against deflection force of splinted periodontally compromised teeth with hypermobility. J Mech Behav Biomed Mater 2023; 142:105873. [PMID: 37119722 DOI: 10.1016/j.jmbbm.2023.105873] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 04/10/2023] [Accepted: 04/24/2023] [Indexed: 05/01/2023]
Abstract
This study aimed to evaluate the effect of splinting material type and material location on the force resistance of splinted periodontally compromised teeth with hypermobility. Extracted teeth including the target tooth (maxillary second premolar) and its adjacent teeth were placed into the alveolar sockets of a dental arch model via artificial periodontal ligaments made of elastic impression material. Three different experimental models with varied target tooth mobility including Periotest® values (PTVs) of 20, 30, and 40 were fabricated (named models #20, #30, and #40, respectively). For each experimental model, the force resistance of tooth splinting was tested using the following four materials: everStick PERIO (glass fiber reinforcement: GFR), FORESTAFLEX (braided stainless steel: BSS), Ortho-FlexTech (stainless steel chain: SSC), and Super-Bond (MMA-based resin cement: MRC). The evaluated measures were the PTV after tooth splinting and the required load to cause tooth displacements of 0.05 mm and 0.10 mm in the vertical and lateral directions, respectively. The splinting material type and material location as well as the original PTV of target the tooth significantly affected all the evaluated measures (p < 0.001). MRC revealed the significantly highest force resistance of tooth splinting regardless of material location in each experimental model and was followed by GFR. The PTVs of splinted teeth were comparable to those of adjacent anchor teeth in models #20 and #30 when using GFR, while that was comparable in model #40 when using MRC. Meanwhile, the load causing certain tooth displacement showed a similar tendency to previous-reported data with healthy teeth in model #20 when using GFR, while that showed a similar tendency in models #30 and #40 when using MRC. Overall results concluded that splinting material type and location play a role in the resistance against the deflection force of splinted periodontally compromised hypermobile tooth. It was noted that MRC provided the highest resistance against the deflection force of splinted teeth regardless of material location whereas GFR maintained the physiologically considered tooth mobility.
Collapse
|
10
|
Effect of Surface Polishing on Physical Properties of an Occlusal Splint Material for Additive Manufacturing under Protection Gas Post-Curing Condition. Polymers (Basel) 2023; 15:polym15030625. [PMID: 36771926 PMCID: PMC9919341 DOI: 10.3390/polym15030625] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2022] [Accepted: 01/19/2023] [Indexed: 01/27/2023] Open
Abstract
The aim of this study was to evaluate the effect of surface polishing as well as the post-curing atmospheres (air and nitrogen gas) on the physical properties of an occlusal splint material for additive manufacturing. Flexural strength, flexural modulus, Vickers hardness number (VHN), degree of carbon double bond conversion (DC), water sorption (WSP), and water solubility (WSL) were evaluated. Surface polishing significantly affected the evaluated properties. Regardless of the post-curing atmosphere, flexural strength, flexural modulus, VHN, and DC showed significantly higher values for the polished specimens when compared with the unpolished ones, while WSP and WSL were significantly lower for the polished specimens. Unpolished specimens post-cured at nitrogen gas showed significantly higher VHN and DC values. However, the effect of the post-curing at a nitrogen gas atmosphere was non-significant in polished specimens. The current results suggested that surface polishing plays a role in the physical properties of the evaluated occlusal splint material and can enhance all the evaluated properties regardless of the post-curing atmosphere. Meanwhile, the post-curing at a nitrogen gas atmosphere can enhance the VHN and DC but its effect is confined only to the surface layers, which can be removed during surface polishing.
Collapse
|
11
|
POS1475-HPR THE MINIMALLY IMPORTANT DIFFERENCE AS THE INTERPRETABILITY OF EMOTIONAL HEALTH DOMAIN IN JAPANESE VERSION OF LupusPRO FOR SLE PATIENTS; PRELIMINARY RESULTS OF A PROSPECTIVE COHORT STUDY. Ann Rheum Dis 2022. [DOI: 10.1136/annrheumdis-2022-eular.1406] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
BackgroundThe minimally important difference (MID) required to interpret the magnitude of changes in lupus patient-reported outcome (LupusPRO), which is a widely used outcome measure of quality of life in SLE patients, remains unclear.ObjectivesWe report preliminary results of an ongoing prospective observational study that assesses the MID as the interpretability of emotional health (EH) domain in Japanese version of LupusPRO.MethodsWe recruited subjects at three university hospitals in Japan participating in an ongoing multidisciplinary cohort study (the Lupus registry of Nationwide institutions (LUNA). Of a total of 210 SLE patients enrolled during the 17-month recruitment period, patients with low disease activity, defined as SLE Disease Activity Index 2000 (SLEDAI-2K) ≤ 4, and who were seen at least twice of three months’ duration and responded to both the LupusPRO and health status change questions were included in this subcohort. The second questionnaire was given an allowance period of 30 days before or after the three months from starting date. Descriptive statistics were presented as means and standard deviations (SD) or counts and percentages (%). The emotional health score ranges from 0 to 100; a higher score indicates less frequent presence of symptoms. The change in health status was assessed using the 7-point Global Rating of Change 1), and the score = 0 and the score ≥ +1 were considered in the ‘unchanged’ and the minimal ‘improved’ category, respectively. MID was mainly estimated using the mean change of the groups with the score ≥ +1 as the anchor-based method, and the area under the curve (AUC) was also calculated as a sensitivity analysis to estimate MID thresholds 2) and 95% confidence intervals (CI) were constructed using 1000 bootstrapping.ResultsThe mean age of the 24 eligible patients was 48 (SD 14), and 88% were female. The glucocorticoid dose, SLEDAI-2K, and Systemic Lupus International Collaborating Clinics /American College of Rheumatology Damage Index were 3.4 (2.1) mg, 1.0 (1.1) and 1.1 (1.9), respectively. The mean EH score was 67.5 (30.3), five patients (21%) had the maximum EH score at baseline, 73.4 (25.0) after three months, 7.2 (18.0) for the change in EH. The correlation coefficient and the AUC for the change in health status and the EH were 0.23 and 0.60. The mean changes were 4.1 (18.4) of the groups with ‘unchanged’ health status and 12.3 (17.1) of the groups with ‘improved’ health status. The MID for improvement was estimated at 12.3 using the anchor-based method, and the cutoff point corresponded to 9.3 [95%CI -6.7 to 25.3]) of the EH change score by the receiver operating curve method.ConclusionIn this study, the MID (3 months) for the EH domain in the Japanese version of LupusPRO was estimated to be between 9 and 12, which was similar to the results of the previous cross-sectional study 3). The challenge in estimating the MID in our setting was the low correlation with external anchors, even though the study population was limited to patients with low disease activity, because disease activity at baseline can generally influence ‘improved’ health status.References[1]Kamper SJ, Maher CG, Mackay G. Global rating of change scales: a review of strengths and weaknesses and considerations for design. J Man Manip Ther. 2009;17(3):163.[2]Froud R, Abel G. Using ROC curves to choose minimally important change thresholds when sensitivity and specificity are valued equally: the forgotten lesson of pythagoras. theoretical considerations and an example application of change in health status. PLoS One. 2014;9(12):e114468.[3]Miyawaki Y, Shimizu S, Ogawa Y, et al. Association of glucocorticoid doses and emotional health in lupus low disease activity state (LLDAS): a cross-sectional study. Arthritis Res Ther. 2021;23(1):79.AcknowledgementsThe authors thank Yuka Nakanou for her significant assistance in data management and Kikuko Miyazaki for her expert assistance on this topic.Disclosure of InterestsYoshia Miyawaki: None declared, Kenta Shidahara: None declared, Shoichi Nawachi: None declared, Yosuke ASANO: None declared, Yu Katayama: None declared, Keiji Ohashi: None declared, Eri Katsuyama: None declared, Takayuki Katsuyama: None declared, Mariko Narazaki: None declared, Yoshinori Matsumoto Speakers bureau: I received speaker’s fees from Glaxo Smith Kline K.K., KEN-EI SADA Speakers bureau: I received speaker’s fees from Glaxo Smith Kline K.K., Ryo Yanai: None declared, Nobuyuki Yajima: None declared, Ayuko Takatani: None declared, Kunihiro Ichinose: None declared, Jun Wada Speakers bureau: Jun Wada receives speaker honoraria from Astra Zeneca, Daiichi Sankyo, Novartis, Novo Nordisk Pharma, Tanabe Mitsubishi and receives grant support from Astellas, Baxter, Bayer, Chugai, Dainippon Sumitomo, Kyowa Kirin, Novo Nordisk Pharma, Ono, Otsuka, Tanabe Mitsubishi, and Teijin.
Collapse
|
12
|
Effect of retention hole designs in artificial teeth on failure resistance of the connection with thermoplastic resin. Dent Mater J 2022; 41:573-579. [PMID: 35418549 DOI: 10.4012/dmj.2021-328] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
This study aimed to evaluate the effect of retention hole designs in artificial teeth on failure resistance of the connection with a thermoplastic denture base resin. Artificial teeth with the following retention hole designs were attached to polyester and polyamide resins: no hole, vertical hole, horizontal hole, and vertical and horizontal holes. An artificial tooth with no hole attached to polymethyl methacrylate was prepared as the control. The load was applied until connection failure occurred between the artificial tooth and resin, and failure resistance was detected. Although the control showed the highest resistance, the artificial tooth with vertical and horizontal holes showed higher resistance than those with other retention hole designs in both thermoplastic resins. Providing vertical and horizontal retention holes in artificial teeth may be effective in improving failure resistance of the connection with thermoplastic resins.
Collapse
|
13
|
Evaluation of PEEK and zirconia occlusal rest designs for removable partial dentures based on finite element analysis. J Prosthodont Res 2022; 67:196-205. [PMID: 35644568 DOI: 10.2186/jpr.jpr_d_22_00011] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Purpose We aimed to assess removable partial denture occlusal rests composed of polyether-ether-ketone (PEEK) and zirconia, using finite element analysis.Methods Three-dimensional PEEK and zirconia rest models, including the occlusal rest (1.5 mm thickness at the basal portion, 3.0 mm width) and minor connector (1.5 mm thickness, 6.0 mm height), and rest seat models with mechanical properties of enamel were constructed. The radius of transitional curvature between the rest and minor connector was 0.1-0.5 mm. The rest and rest seat model interfaces were set as frictional contacts (μ = 0.1), and the base of the rest seat model was restrained in all the directions. A 100 N downward load was applied perpendicular to the bottom surface of the minor connector. The maximum value of the first principal stress (Max-S1) was compared to the flexural and fatigue strengths of each material. Occlusal rests with 1.0-2.0 mm thickness, 2.0-3.5 mm width, and 0.5 mm radius of transitional curvature were analyzed.Results Max-S1 was observed at the transitional part and decreased with increasing radius of the transitional curvature, rest width, and thickness. PEEK rests with at least 1.5 mm thicknesses and 3.0 mm widths showed lower Max-S1 than the flexural strength. Max-S1 of all PEEK rests exceeded the PEEK fatigue strength, whereas Max-S1 of the zirconia rests was lower than the zirconia fatigue strength.Conclusions Zirconia occlusal rests with conventional metal rest designs have sufficient fatigue strength. PEEK occlusal rests have insufficient fatigue strength and may not withstand repeated mastication.
Collapse
|
14
|
Effect of night dentures on tooth mobility in denture wearers with sleep bruxism: a pilot randomized controlled trial. J Prosthodont Res 2021; 66:564-571. [PMID: 34789636 DOI: 10.2186/jpr.jpr_d_21_00230] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE The purpose of this study was to investigate the inhibitory effect of night denture (ND) placement on abutment tooth mobility in removable partial denture (RPD) wearers with sleep bruxism (SB). METHODS The participants were selected from RPD wearers diagnosed with SB using BiteStrip® and randomly allocated to one of the following groups: with ND placement or without ND placement (intervention or control group, respectively). The mobility of the RPD abutment tooth was measured using Periotest® at baseline (T0) and at 1 (T1), 3 (T3), and 6 months (T6). BiteStrip® scores were recorded at T0 and T6. Intragroup comparisons of the Periotest® value (PTV) were performed using analysis of covariance. Intergroup comparisons of PTV and BiteStrip® scores were performed using the linear mixed model and Wilcoxon signed-rank test, respectively. Intragroup comparisons of BiteStrip® scores were performed using the Mann-Whitney U test. RESULTS At T6, the PTV in the intervention group was significantly lower than that in the control group (p=0.004). PTV was significantly lower at T6 than that at T0 in the intervention group (p=0.030), while PTV was significantly higher at T6 than that at T0 in the control group (p=0.007). There was no significant difference in the BiteStrip® score between the two groups. The BiteStrip® score at T6 was significantly lower than that at T0 only in the intervention group (p=0.011). CONCLUSION ND placement might inhibit the increase in mobility of RPD abutment teeth and be effective in protecting them in RPD wearers with SB.
Collapse
|
15
|
Long-term observation of periodontal condition following placement of removable partial dentures with rigid retainers and major connector in patients with/without diabetes: A retrospective study. J Prosthodont Res 2021; 66:117-123. [PMID: 34108298 DOI: 10.2186/jpr.jpr_d_20_00288] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE This retrospective study evaluated the periodontal tissues of the abutment teeth of removable partial dentures (RPDs) with rigid retainers and major connectors in patients with and without type 2 diabetes mellitus (T2D). METHODS A total of 313 patients who had been treated with RPDs, including rigid retainers and major connectors, were divided into two groups: T2D and non-T2D. The periodontal parameters and radiographic bone heights of the abutment teeth were evaluated at baseline and at a 5-year examination during supportive periodontal therapy (SPT). For patients with accessible standardized radiographs, bone density was analyzed based on the gray level (GL) using digital subtraction radiography (n = 83). RESULTS Overall, 739 abutment teeth (86 in the T2D group) of 235 patients (25 in the T2D group) were analyzed, and 95.0% (94.2% in the T2D group, and 95.2% in the non-T2D group) were maintained. The mean probing pocket depth significantly increased in both groups ( p < 0.001). There were significant changes in the radiographic bone height (p = 0.038) and GL on the side of the denture base area (p = 0.048) in the T2D group compared to those in the non-T2D group. CONCLUSIONS Regardless of T2D, RPDs with rigid retainers and major connectors could prevent the progression of periodontal disease and successfully maintain most of the abutment teeth during 5-years of SPT. However, T2D may be significantly associated with loss of bone height reduction and density on the side of the denture base area.
Collapse
|
16
|
A systematic review of digital removable partial dentures. Part I: Clinical evidence, digital impression, and maxillomandibular relationship record. J Prosthodont Res 2021; 66:40-52. [PMID: 33504721 DOI: 10.2186/jpr.jpr_d_20_00116] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE This study comprehensively reviewed the current status of digital workflows in fabricating removable partial dentures (RPDs) using evidence from clinical trials and case reports. STUDY SELECTION We performed a systematic review of the literature on the materials and fabrication of RPDs using digital technologies published in online databases from 1980 to 2020. We selected eligible articles from the search results, retrieved information on digital RPDs from these, and conducted a qualitative analysis. We report evidence from clinical papers and case reports, digital impression-taking methods, and maxillomandibular relationship (MMR) records. RESULTS A case report electronically published in 2019 introduced a clasp-retained RPD fabricated via a full-digital workflow without a gypsum definitive cast. Computer-aided design and computer-aided manufacturing of double-crown-retained RPDs with nonmetal materials were described in some case reports. Intraoral scanners were used to obtain digital impressions and MMR records in the fabrication of digital RPDs, which have potential advantages for reducing the number of clinical appointments and simplifying laboratory procedures. Evidence from clinical trials is scarce; a randomized controlled trial reported higher patient satisfaction with digital clasp-retained RPDs than with conventional RPDs. CONCLUSIONS Full-digital RPDs can be fabricated without a gypsum definitive cast. However, the indication for full-digital RPDs is limited to cases with Kennedy Class III/IV partially edentulous arches with several missing teeth. Challenges in digital impression-taking and MMR recording remain to be solved to extend these indications. More evidence from clinical trials is required to evaluate the efficacy and usefulness of digital R PDs.
Collapse
|
17
|
A systematic review of digital removable partial dentures. Part II: CAD/CAM framework, artificial teeth, and denture base. J Prosthodont Res 2021; 66:53-67. [PMID: 33504722 DOI: 10.2186/jpr.jpr_d_20_00117] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE This study comprehensively reviewed the current status of the digital workflow of removable partial dentures (RPDs) and summarized information about the fabrication methods and material properties of the dental framework, artificial teeth, and denture base. STUDY SELECTION We performed a systematic review of the literature published in online databases from January 1980 to April 2020 regarding RPD fabrication and materials used in the related digital technology. We selected eligible articles, retrieved information regarding digital RPDs, and conducted qualitative/quantitative analyses. In this paper, the computer-aided design/computer-aided manufacturing (CAD/CAM) framework, artificial teeth, and denture base materials are reported. RESULTS A variety of materials, such as cobalt-chromium alloy, titanium, zirconia, and polyether ether ketone, are used for dental CAD/CAM frameworks. The mechanical strength of the metal materials used for the CAD/CAM framework was superior to that of the cast framework. However, the fitness and surface roughness of the framework and clasp fabricated using a selective laser melting (SLM) method were not superior to those obtained via cast fabrication. Most material properties and the surface roughness of poly methyl methacrylate (PMMA) discs used for digital RPDs were superior to those of heat-cured PMMA. CONCLUSIONS The use of a CAD/CAM framework and PMMA disc for digital RPDs offers numerous advantages over conventional RPDs. However, technical challenges regarding the accuracy and durability of adhesion between the framework and denture base remain to be solved. In digital fabrication, human technical factors influence the quality of the framework.
Collapse
|
18
|
Replica-based inspection of enamel wear microfeatures. Biomed Mater Eng 2020; 31:279-290. [PMID: 32986650 DOI: 10.3233/bme-206006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Surface replication is a nondestructive evaluation technique applied in examining surface wear by recording surface irregularities, especially in conditions when surfaces of interest cannot be further manipulated to fit directly under a microscope to be examined. Enamel is the outermost protective layer of the human teeth and is constantly stressed by mastication forces which results in enamel wear. OBJECTIVE To date, a procedure combining the clinical and microscopic examination of enamel surfaces is absent, which hinders the early diagnosis and comprehension of the wear process. METHODS This study investigated the role of replication sheets in registering microscopic wear on human enamel surfaces by both negative and positive replication techniques. RESULTS The sheets replicated wear features successfully. Sheets were compatible to use with multiple microscopes, with proper preparation, including high resolution microscopes such as the scanning electron microscope and transmitting electron microscope.
Collapse
|
19
|
AB0387 TREATMENT STATUS FOR OSTEOPOROSIS IN PATIENTS WITH SYSTEMIC LUPUS ERYTHEMATOSUS: CROSS-SECTIONAL ANALYSIS FROM A LUPUS REGISTRY OF NATIONWIDE INSTITUTIONS (LUNA). Ann Rheum Dis 2020. [DOI: 10.1136/annrheumdis-2020-eular.1202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Background:Osteoporosis is one of the most important adverse effects of glucocorticoids in patients with systemic lupus erythematosus (SLE). Because osteoporosis is accelerated by chronic kidney disease (CKD), more attention should be paid to the treatment for osteoporosis in SLE patients with CKD. Many treatment options for osteoporosis have emerged recently, but treatment status in patients with SLE is not elucidated.Objectives:The purpose of this study is to elucidate the treatment status for osteoporosis in patients with SLE among the CKD stages.Methods:Using data from lupus registry of nationwide institutions (LUNA), a cross-sectional analysis was performed. We firstly described treatment status for osteoporosis in all enrolled patients. Secondary, treatment status for osteoporosis was compared among CKD stages. Finally, bone damage in Systemic Lupus International Collaborating Clinics/American College of Rheumatology Damage Index (SDI) was compared among CKD stages.Results:The median age (interquartile range [IQR]) of enrolled 917 patients was 44 (34- 57) years and 809 patients (88%) were female. CKD stages were follows: CKD stage 1, 234 (26%); CKD stage 2, 465 (51%); CKD stage 3, 189 (21%); CKD stage 4, 9 (1%); CKD stage 5, 16 (2%). Median (IQR) age, female sex, and median (IQR) previous maximum dose of prednisolone in patients with and without CKD (≥CKD stage 3) were 56 (46.5-66) and 41 (32-50), 191 (89%) and 615 (88%), and 40 (30-60) and 40 (30-55) mg/day, respectively. Bisphosphonate was administered in 388 (42%) patients, vitamin D supplements in 448 (49%), Ca supplements in 36 (4%), denosumab in 20 (2%) and teriparatide in 14 (2%), respectively. Of enrolled patients, any treatment for osteoporosis was not administered in 226 (25%) patients. In spite of more frequent bone damage in patients with CKD compared to those without CKD (15% vs 10%, p=0.036), treatment status did not differ between patients with and without CKD (bisphosphonate: 41% vs 46%, p=0.29; vitamin D supplements: 50% vs 44%, p=0.14).Conclusion:About a quarter of patients with SLE did not take any treatment for osteoporosis. Treatment for osteoporosis might be strengthened to prevent bone damage in SLE patients with CKD.Disclosure of Interests:KEN-EI SADA Speakers bureau: I received speaker’s fee from GSK and Astra Zeneca K.K., Keigo Hayashi: None declared, Yosuke ASANO: None declared, Yu Katayama: None declared, Sumie Hiramatsu Asano: None declared, Keiji Ohashi: None declared, Michiko Morishita: None declared, Haruki Watanabe: None declared, Mariko Narazaki: None declared, Yoshinori Matsumoto: None declared, Nobuyuki Yajima: None declared, Ryusuke Yoshimi: None declared, Yasuhiro Shimojima: None declared, Shigeru Ono: None declared, Hiroshi Kajiyama: None declared, Kunihiro Ichinose: None declared, Shuzo Sato: None declared, Michio Fujiwara: None declared, Jun Wada: None declared
Collapse
|
20
|
Influence of retainer and major connector designs of removable partial dentures on the stabilization of mobile teeth: A preliminary study. Dent Mater J 2020; 39:89-100. [PMID: 31582595 DOI: 10.4012/dmj.2018-272] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The purpose of this study was to investigate the influence of retainers and major connector designs on the stabilization of remaining mobile teeth using removable partial dentures (RPDs). We prepared experimental RPDs with several retainer designs and major connectors for lower Kennedy class I models. The simulated RPD insertion and removal test was conducted and retentive force and mobility of mobile remaining teeth with and without RPD placement were measured throughout a simulation test. Regardless of reduction of retentive force, the placement of RPDs using cast clasps and/or lingual plates resulted in reduced mobility of the remaining teeth than use of wrought wire clasps and/or lingual bars. The results suggested that cast clasps and lingual plates are effective for the stabilization of mobile, remaining teeth. Additionally, the stabilizing effect of RPD on abutment teeth was not diminished, despite decreases in retentive force.
Collapse
|
21
|
Damage accrual related to pregnancies before and after diagnosis of systemic lupus erythematosus: a cross-sectional and nested case-control analysis from a lupus registry. Lupus 2020; 29:176-181. [PMID: 31924143 DOI: 10.1177/0961203319898766] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVE The objective of this study was to evaluate the chronic damage associated with pregnancies before and after the diagnosis of systemic lupus erythematosus (SLE). METHODS Using childbearing-aged female SLE patient data registered at the Okayama and Showa University Hospitals, a nested case-control analysis was performed to investigate the relationship between pregnancy and chronic damage using the Systemic Lupus International Collaborating Clinics/American College of Rheumatology Damage Index (SDI). RESULTS Pregnancy occurred in 22 patients before and 13 patients after the diagnosis of SLE in 104 eligible patients. Live births occurred in 82% (33/40) and 50% (9/18) of the pregnancies before and after the diagnosis of SLE, respectively. After matching age and disease duration, 33 case patients with chronic damage (SDI ≥ 1) and 33 control patients without chronic damage (SDI = 0) were selected. Hypertension was more frequent in cases than in controls (48% vs. 24%, p = 0.041). Pregnancies before and after the diagnosis of SLE were comparable between cases and controls (before the diagnosis: nine case patients and eight control patients; after the diagnosis: three case patients and five control patients; p = 1.00). Even after adjusting for hypertension using multivariate analysis, the pregnancies before and after the diagnosis were not significant predictors for chronic damage (odds ratio = 1.48 (95% confidence interval 0.33-6.65)), p = 0.60 of the pregnancy before the diagnosis; odds ratio = 0.78 (95% confidence interval 0.13-4.74), p = 0.78 of the pregnancy after the diagnosis). CONCLUSION Pregnancies, either before or after the diagnosis of SLE, did not show any differences in chronic damage. Our results help alleviate fears regarding childbearing in female patients with SLE and their families.
Collapse
|
22
|
Influence of the Covering Area of Major Connectors of Mandibular Dentures on the Accuracy of Speech Production: A Pilot Study. Folia Phoniatr Logop 2019; 72:419-428. [PMID: 31851965 DOI: 10.1159/000502954] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Accepted: 08/23/2019] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND/OBJECTIVES Speech impairment during the initial phase of removable partial denture (RPD) treatment can prevent patient adaptation to RPDs. This quasi-experimental study aimed to investigate the influence of the covering area of major connectors located in the mandibular anterior region on the accuracy of speech production. METHODS Fifteen adults (12 men and 3 women aged 26-40 years) with healthy dentition were recruited. Four target syllables were used for the assessments: [ʃi], [ʧi], [çi], and [ki]. There were four speaking conditions: without a connector (control), wearing lingual bar (5 mm width), wearing lingual plates (12 mm width), and wearing connectors covering the occlusal surface of lower dentition (16 mm width; CO). The accuracy of speech production was evaluated by mean appearance ratio of correct labels (MARC) and incorrect labels (MARIC) of the phonetic segments which were calculated with a speech evaluation system (VoiceAnalyzer). RESULTS The MARC in the 3 target syllables [ʃi], [ʧi], and [ki] significantly decreased with CO. For the target syllable [ʃi], the MARICs of [ʧi], [ʤi], and [çi] with CO were significantly lower than that in the control. For the target syllable [ʧi], the MARIC of [ki] with CO was significantly higher than that in the control. For the target syllable [çi], the MARIC of [gi] with CO was significantly higher than that in the control. CONCLUSION RPDs with major connectors covering the lower dentition could disturb speech production during the initial phase of RPD treatment. Prosthodontic treatment with such RPD designs requires further consideration regarding the information given to patients before starting the treatment.
Collapse
|
23
|
The application of cellulose acetate replication sheets in enamel wear investigations. Dent Mater J 2019; 38:86-95. [PMID: 30224600 DOI: 10.4012/dmj.2017-444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Surface replication is a nondestructive evaluation technique applied in examining surfaces' cracks/wear. This is quite valuable when the surface of interest cannot be further manipulated by cutting or polishing to fit directly under a microscope. Replication by acetate sheets is one of the techniques applied in industrial, metallographic and anthropological wear/examination. Enamel is the outermost protective layer of human teeth and is subjected to mechanical stresses due to the masticatory function; thus, wear is inevitable in human teeth. This relatively inert hard tissue has been reported to possess some properties of both metals and glasses due to its unique delicate microstructure. This study investigated the applicability of replication sheets in registering wear induced features on human enamel surfaces. The sheets replicated wear features successfully with compatibility to use with multiple microscopes. Acetate sheets have a potential in enamel wear replication.
Collapse
|
24
|
Progressive reduction of serum complement levels: a risk factor for relapse in patients with hypocomplementemia in systemic lupus erythematosus. Lupus 2018; 27:2093-2100. [DOI: 10.1177/0961203318804892] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Objective Serologically active clinically quiescent (SACQ)-SLE is a subtype of systemic lupus erythematosus (SLE); most SACQ-SLE patients relapse. Although complement and/or anti-dsDNA level fluctuations during SACQ status are reportedly not useful for predicting relapse, they might be useful in specific clinical settings. We aimed to assess the correlation between future relapse and progressive reductions in serum complement levels following remission in patients with hypocomplementemia . Methods We retrospectively reviewed patients aged ≥15 years who were treated with ≥20 mg/day of prednisolone for remission induction. After achieving remission, the patients treated with prednisolone tapered to ≤15 mg/day without relapse and followed by hypocomplementemia (first hypocomplementemia point) were analyzed. The primary outcome was the relapse during the first 24 months. Results Seventy-six patients were enrolled; 31 (40.8%) relapsed. A ≥10% reduction after the first hypocomplementemia point in serum C3, C4, and CH50 levels was found in 10, 21, and 16 patients, respectively. Hazard ratios (95% confidence intervals) for relapse were 2.32 (0.92–5.12) for serum C3 levels and 2.46 (1.18–5.01) for serum C4 levels. Progressive reductions in serum C3 and C4 levels had relatively high specificity (93.3% and 82.2%) but limited sensitivity (22.6% and 41.9%) for predicting relapse. However, simultaneous progressive reduction in C3 levels and increase in anti-dsDNA antibody levels had the highest specificity (97.8%), and simultaneous progressive reduction in C4 levels or increase in anti-dsDNA antibody levels had the highest sensitivity (71.0%). Conclusion Simultaneous progressive reductions in complement levels and increases in anti-dsDNA antibody levels may indicate future relapse SACQ-SLE patients.
Collapse
|
25
|
Influence of Oral Morphology on Speech Production in Subjects Wearing Maxillary Removable Partial Dentures with Major Connectors. Folia Phoniatr Logop 2018; 70:138-148. [PMID: 30138930 DOI: 10.1159/000491789] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2017] [Accepted: 06/29/2018] [Indexed: 01/04/2023] Open
Abstract
BACKGROUND/AIMS Speech impairment during the initial phase of removable partial denture (RPD) treatment can prevent patient adaptation to RPDs. This study was undertaken to investigate the influence of oral morphology on speech production in subjects wearing RPDs with major connectors. METHODS Two types of connectors were fabricated for 17 subjects with normal dentitions: covering the middle palate (M-bar) and the anterior/posterior palate (AP-bar). Four target sounds ([∫i], [t∫i], [çi], and [ki]) were evaluated under 3 recording conditions: no connector, M-bar, and AP-bar. The mean appearance ratios of correct labels (MARCs) were calculated as parameters representing speech production accuracy with the speech evaluation system. Subgroup analysis was conducted based on palate height, dental arch width, and front space volume of the oral cavity. RESULTS Based on the multiple linear regression test, a significant association was found between the MARCs of [∫i] with M-bar and front space (p = 0.036). In the subgroup analysis, the AP-bar had a significant effect on the MARCs of [∫i] among subjects with high palate (p = 0.026), narrow arch (p = 0.004), and small front space (p = 0.014). CONCLUSION RPDs with major connectors could disturb speech production among patients with high palates, narrow arches, and small front spaces.
Collapse
|
26
|
Cover Image. J Oral Rehabil 2018. [DOI: 10.1111/joor.12630] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
27
|
Refractory neuromyelitis optica spectrum disorder in systemic lupus erythematosus successfully treated with rituximab. Lupus 2018. [PMID: 29498304 DOI: 10.1177/0961203318760994"] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
We present a case of a woman with systemic lupus erythematosus (SLE) who had refractory episodes of neuromyelitis optica spectrum disorder (NMOSD) and was successfully treated with rituximab. She was positive for anti-aquaporin-4 (AQP4) antibody and had typical cranial and longitudinally extended spinal lesions but no optic nerve involvement. There is no established treatment for NMOSD/SLE overlap cases. Our experience suggests that rituximab may be effective for patients with combined SLE and anti-AQP4 antibody-positive NMOSD.
Collapse
|
28
|
Refractory neuromyelitis optica spectrum disorder in systemic lupus erythematosus successfully treated with rituximab. Lupus 2018; 27:1374-1377. [DOI: 10.1177/0961203318760994] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
We present a case of a woman with systemic lupus erythematosus (SLE) who had refractory episodes of neuromyelitis optica spectrum disorder (NMOSD) and was successfully treated with rituximab. She was positive for anti-aquaporin-4 (AQP4) antibody and had typical cranial and longitudinally extended spinal lesions but no optic nerve involvement. There is no established treatment for NMOSD/SLE overlap cases. Our experience suggests that rituximab may be effective for patients with combined SLE and anti-AQP4 antibody-positive NMOSD.
Collapse
|
29
|
Head position affects the direction of occlusal force during tapping movement. J Oral Rehabil 2018; 45:363-370. [PMID: 29446484 DOI: 10.1111/joor.12618] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/12/2018] [Indexed: 11/29/2022]
Abstract
Despite numerous reports describing the relationship between head position and mandibular movement in human subjects, the direction and magnitude of force at the occlusal contacts have not been investigated in relation to head position. The objective was to investigate the effect of head position on the direction of occlusal force while subjects performed a tapping movement. Twenty-three healthy adult subjects were asked to sit on a chair with their back upright and to perform 15 tapping movements in five different head positions: natural head position (control); forward; backward; and right and left rolled. The direction and magnitude of force were measured using a small triaxial force sensor. The Wilcoxon signed-rank test and Bonferroni test were used to compare head positions in each angle of the anteroposterior axis direction and the lateral axis direction with respect to the superior axis. The force element in the anteroposterior axis shifted to the forward direction in the head position pitched backward, compared with control, pitched forward and rolled left positions (P = .02, <.01 and <.01, respectively). The force direction in the lateral axis with the head position rolled to the right or left shifted to the left and right directions, respectively, compared with those in the other positions (P < .05). Results of this study suggest that the head should be maintained in a position in which a stable tapping movement can be performed in a relaxed position without anteroposterior and lateral loading.
Collapse
|
30
|
Wear characteristics of trimethylolpropane trimethacrylate filler-containing resins for the full crown restoration of primary molars. Dent Mater J 2017; 35:585-93. [PMID: 27477223 DOI: 10.4012/dmj.2015-149] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Although the demand for aesthetic restoration of primary molars has increased, the full-crown restorations using resin and the details of the wear characteristics of trimethylolpropane trimethacrylate (TMPT) filler containing resins for primary molars are not well understood. This study was conducted to determine whether new light-cured composite resin (Fantasista) and 4-META/MMATBB resin (Bondfill SB) are appropriate for full crown restoration of primary molars by evaluating their wear characteristics. Both resins products contain TMPT filler. The properties of the resins were evaluated through in vitro impacting-sliding wear tests; the wear properties of the opposing enamel specimens used in the tests were also studied. The properties of the resins were compared with those of Litefill, MetafilC, and Clearfil FII, which had been evaluated previously. Fantasista exhibited simple shape of wear that was suggestive of a higher wear resistance than that of Litefill. Fantasista caused the least damage to the antagonistic primary enamel.
Collapse
|
31
|
P5398Vasohibin-2 exacerbates development of angiotensin II-induced thoracic aortic aneurysms independent of VEGF. Eur Heart J 2017. [DOI: 10.1093/eurheartj/ehx493.p5398] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
32
|
Chronological grey scale changes in supporting alveolar bone by removable partial denture placement on patients with periodontal disease: A 6-month follow-up study using digital subtraction analysis. J Dent 2017; 63:8-13. [PMID: 28478215 DOI: 10.1016/j.jdent.2017.05.004] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2017] [Revised: 04/27/2017] [Accepted: 05/02/2017] [Indexed: 01/01/2023] Open
Abstract
OBJECTIVES The purpose was to assess the early effects of removable partial denture (RPD) placement on abutment teeth in patients with periodontal disease. METHODS Fifteen distal-extension RPDs and 19 abutment teeth were evaluated in 13 patients with moderate-to-severe periodontal diseases. Clinical periodontal records and grey level (GL) score based on digital subtraction radiography were measured on the day of denture placement (baseline) and at 1day, 1 week, 1 month, 3 months, and 6 months after the placement. Occlusal force on total dentition (Ft) and abutment tooth (Fa) were recorded with (baseline) and without denture on the day of the placement, and with denture in the follow-up examinations. RESULTS No statistically significant difference between a follow-up period and the baseline was found in the clinical periodontal and occlusal force records, except for Ft with denture on the day of the placement, which was significantly lower than the baseline (p<0.05). The GL at distal crestal of the abutment was significantly higher at 1 week after the placement than at the baseline (p<0.05), while the scores of following examinations returned to the baseline level. CONCLUSIONS The distal crestal bone of the abutment tooth transitorily reacts to mechanical stress due to the denture placement, while this does not suggest a detrimental effect within the limitation of the study design with a short-term observation period. CLINICAL SIGNIFICANCE The RPDs can be safely used for patients with periodontal diseases for at least 6 months if they are properly placed and maintained by professional care.
Collapse
|
33
|
|
34
|
The efficacy of add-on tacrolimus for minor flare in patients with systemic lupus erythematosus: a retrospective study. Lupus 2015; 25:54-60. [DOI: 10.1177/0961203315600538] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2015] [Accepted: 07/07/2015] [Indexed: 01/16/2023]
Abstract
Objective We have assessed the effectiveness of tacrolimus for minor flares in systemic lupus erythematosus (SLE) patients. Methods The medical records of 313 patients were retrospectively reviewed over a period of seven years, from 2006 to 2013. We enrolled patients with minor flare treated with add-on tacrolimus, without glucocorticoid (GC) intensification (tacrolimus group). Minor flare was defined as a ≥1-point increase in a total score between 3 and 11 in the SLE Disease Activity Index (SLEDAI). We enrolled as controls patients who were administered increased doses of GC for minor flare (GC group). All patients were followed for one year. The primary outcome measure was the proportion of responders. Results There were 14 eligible patients in the tacrolimus group and 20 eligible patients in the GC group. The mean SLEDAI at flare tended to be higher in the tacrolimus group than in the GC group (7.5 vs. 6.2, p = 0.085). A mean dose of 1.6 mg tacrolimus/day was administered for flare, while the mean GC dose was 13.7 mg/day in the GC group. The proportion of responders was 86% (12/14) in the tacrolimus group and 75% (15/20) in the GC group ( p = 0.67). The mean dose of GC at 12 months was higher in the GC group than in the tacrolimus group (9.7 mg/day vs. 7.1 mg/day, p < 0.05). Only one patient discontinued tacrolimus because of fatigue after three months. Conclusion Adding tacrolimus without increasing the GC dose may provide an effective treatment option for minor flares in patients with SLE.
Collapse
|
35
|
Insulin-like growth factor-I receptor in metanephric development. CONTRIBUTIONS TO NEPHROLOGY 2015; 107:168-73. [PMID: 8004964 DOI: 10.1159/000422976] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
36
|
Classification of chronic glomerulonephritis based on prognostic considerations. CONTRIBUTIONS TO NEPHROLOGY 2015; 4:96-113. [PMID: 797524 DOI: 10.1159/000399700] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Based on the correlation of LM, EM and IF findings of kidney biopsy tissues with the clinical and laboratory findings as well as renal function, classification of primary GN is proposed with special reference to the smouldering and progressive forms of chronic GN. The two forms of chronic GN should be differentiated because their prognoses are different.
Collapse
|
37
|
Influence of the width and cross-sectional shape of major connectors of maxillary dentures on the accuracy of speech production. Folia Phoniatr Logop 2015; 66:227-36. [PMID: 25659604 DOI: 10.1159/000369439] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2014] [Accepted: 10/28/2014] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVE To investigate the effects of the width and cross-sectional shape of the major connectors of maxillary dentures located in the middle area of the palate on the accuracy of phonetic output of consonants using an originally developed speech recognition system. PATIENTS AND METHODS Nine adults (4 males and 5 females, aged 24-26 years) with sound dentition were recruited. The following six sounds were considered: [∫i], [t∫i], [ɾi], [ni], [çi], and [ki]. The experimental connectors were fabricated to simulate bars (narrow, 8-mm width) and plates (wide, 20-mm width). Two types of cross-sectional shapes in the sagittal plane were specified: flat and plump edge. The appearance ratio of phonetic segment labels was calculated with the speech recognition system to indicate the accuracy of phonetic output. Statistical analysis was conducted using one-way ANOVA and Tukey's test. RESULTS The mean appearance ratio of correct labels (MARC) significantly decreased for [ni] with the plump edge (narrow connector) and for [ki] with both the flat and plump edge (wide connectors). For [çi], the MARCs tended to be lower with flat plates. There were no significant differences for the other consonants. CONCLUSION The width and cross-sectional shape of the connectors had limited effects on the articulation of consonants at the palate.
Collapse
|
38
|
A comparison of the fitting accuracy of thermoplastic denture base resins used in non-metal clasp dentures to a conventional heat-cured acrylic resin. Acta Odontol Scand 2015; 73:33-7. [PMID: 25314120 DOI: 10.3109/00016357.2014.946966] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
OBJECTIVE To incorporate a metal framework into removable partial dentures, the dimensional accuracy of thermoplastic resins requires precision equivalent to conventional acrylic resins. This study aimed to evaluate the fitting accuracy of thermoplastic resins compared to heat-cured acrylic resin. MATERIALS AND METHODS Four thermoplastic resins (polyethylene terephthalate [EstheShot, ES; EstheShot Bright, ES-B], polyamide [Lucitone FRS, LF], polycarbonate [Reigning Resin N, RN] and a heat-curing acrylic resin [Acron, AC]) were used. The specimens were created on master casts constructed of high-strength stone that simulated a maxillary edentulous ridge. Additionally, high-expansion stone was used as the master cast for RN specimens. The ES-B, LF and RN specimens were prepared with and without annealing after injection molding. The gaps between the molded resin and the cast were measured. RESULTS ES had the smallest gap and was significantly smaller than AC (p < 0.05). The gap sizes of ES-B, LF and RN (high-expansion stone) without annealing were similar to AC (p > 0.05), while the gap size of RN (high-strength stone) with and without annealing was significantly greater than AC (p < 0.001). The gap sizes of ES-B and LF with annealing were significantly less than AC (p < 0.05). Further, the gap sizes of ES-B, LF and RN with annealing were significantly smaller than the gaps without annealing (p < 0.05). CONCLUSIONS The results suggested that ES, ES-B and LF have adequate fitting accuracy for incorporating metal framework into dentures and that annealing effectively improved the fitting accuracy of ES-B, LF and RN.
Collapse
|
39
|
Cognitive and affective functions in diabetic patients associated with diabetes-related factors, white matter abnormality and aging. Eur J Neurol 2014; 22:313-21. [DOI: 10.1111/ene.12568] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2014] [Accepted: 08/01/2014] [Indexed: 01/21/2023]
|
40
|
Impact of circulating vaspin levels on metabolic variables in elderly twins. Diabetologia 2012; 55:530-2. [PMID: 22116078 DOI: 10.1007/s00125-011-2385-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2011] [Accepted: 10/26/2011] [Indexed: 11/27/2022]
|
41
|
Influence of the major connector in a maxillary denture on phonetic function. J Prosthodont Res 2011; 55:234-42. [PMID: 21602116 DOI: 10.1016/j.jpor.2011.03.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2010] [Revised: 02/24/2011] [Accepted: 03/23/2011] [Indexed: 11/29/2022]
Abstract
PURPOSE The purpose of this study was to investigate the influence of the major connector in a maxillary denture. METHODS Eight patients with sound dentition were recruited in this study. The experimental connectors were fabricated with Co-Cr. Two positional designs were used: one was the middle type (M), and the other was the anterior and posterior type (AP). The six sounds, /shi/, /hi/, /chi/, /ki/, /ri/, and /ni/, were chosen as the test sounds. Using a speech recognition system, the intelligibility, change and duration of the test sounds were evaluated under three conditions: without connector (WO·C), with the M-type connector (W·M), and with the AP-type connector (W·AP). RESULTS The intelligibility in WO·C and W·AP was 86.9 ± 17.4% and 57.1 ± 30.1% for /shi/, 79.2 ± 19.7% and 70.5 ± 27.0% for /hi/, 74.7 ± 14.6% and 43.6 ± 24.3% for /chi/, 54.4 ± 16.5% and 23.2 ± 17.8% for /ki/, 85.2 ± 15.9% and 55.1 ± 30.6% for /ri/, and 76.9 ± 26.9% and 50.2 ± 31.3% for /ni/. Significant differences were recognized between WO·C and W·AP in /shi/, /chi/, /ki/ and /ri/(P<0.01). The intelligibility in W·M was higher than that in W·AP in all test sounds. As for incorrect labels, significant differences were recognized in the appearance ratio of /hi/ as the incorrect label in the test sound /shi/ (P<0.05). There were significant differences in some incorrect labels of /hi/ and /chi/. As for duration of consonant part, there was no significant difference in each test sound. CONCLUSION It was indicated that the middle type of the major connector would be recommended from a viewpoint of phonetic function.
Collapse
|
42
|
Effect of TGF-β1 expressed on tumor-derived exosomes on survival and function of regulatory T cells. J Clin Oncol 2010. [DOI: 10.1200/jco.2010.28.15_suppl.2567] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
43
|
Comparison of Insulin Detemir and Insulin Glargine on Glycemic Variability in Patients with Type 1 and Type 2 Diabetes. Exp Clin Endocrinol Diabetes 2010; 118:320-4. [DOI: 10.1055/s-0029-1243230] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
44
|
Effects of icodextrin peritoneal dialysis solution on the peritoneal membrane in the STZ-induced diabetic rat model with partial nephrectomy. Nephrol Dial Transplant 2009; 25:1479-88. [DOI: 10.1093/ndt/gfp479] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
45
|
Two cases of ovarian cancer at an early stage incidentally detected using transvaginal ultrasonography in screening: importance of interval for ovarian cancer screening and selection of population with a high risk of ovarian cancer. EUR J GYNAECOL ONCOL 2009; 30:208-210. [PMID: 19480258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Interval of ovarian cancer screening using transvaginal ultrasonography (TVS) and selection of populations with a high risk of this disease are an important issue in detecting early stage-disease. We report two cases of ovarian cancer patients incidentally detected at FIGO Stage I using TVS in the obligatory staff health check. They had undergone other ovarian cancer screening by TVS six months before and received a carefree result at that time. One patient had risk factors (RFs) for ovarian cancer such as obesity and a familal history of ovarian cancer in a first degree relative, and the other had RFs such as obesity and endometrial malignancy. Although cost-effective screening may be important, we recommend that while normal and asymptomatic populations are screened annually, women with any high RFs for ovarian cancer should be screened every six months.
Collapse
|
46
|
Neuroendoscopic trans-third ventricle approach for lesions of the ventral brainstem surface. ACTA ACUST UNITED AC 2008; 51:313-8. [PMID: 19061139 DOI: 10.1055/s-0028-1085446] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Due to the establishment in recent years of neuroendoscopic third ventriculostomy (ETV), it has become possible during ETV to observe the ventral brainstem surface--particularly the prepontine cistern--in a minimally invasive manner via the third ventricular base with a neuroendoscope. As an adaptation of that technique in this study, we investigated a neuroendoscopic trans-third ventricle approach (ETTVA), which accesses lesions of the ventral brainstem surface with a neuroendoscope inserted via the stoma of the third ventricular floor. Our study included 6 cases, including one case each of neurenteric cyst, chordoma, pontine glioma (astrocytoma), ecchordosis physaliphora, endodermal cyst, and cystic schwannoma. Surgical operations performed by ETTVA included 3 cases of tumor resection, 2 cases of tumor biopsy, and 1 case of cyst puncture and aspiration. There were no complications accompanying ETTVA. Out of the 6 cases, only 1 required additional surgical treatment following ETTVA surgery. In the other 5 cases, no additional surgical procedures were performed. This study showed that ETTVA allowed access to the prepontine cistern quickly and in a minimally invasive manner. In selected cases, ETTVA can offer a new approach to these lesions.
Collapse
|
47
|
Depression among caregivers of the frail elderly in Japan before and after the introduction of the Public Long-Term Care Insurance System. Z Gerontol Geriatr 2007; 40:112-8. [PMID: 17450411 DOI: 10.1007/s00391-007-0412-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2006] [Accepted: 10/04/2006] [Indexed: 10/23/2022]
Abstract
Cross sectional studies were conducted in five towns in Japan before and after the introduction of the Long-term Care Insurance System (LTCIS), in order to evaluate the factors relating to depression among family caregivers for the frail elderly. Depressive caregivers were more likely to consult with their doctors, to be in poor health, to care for demented elderly with behavioral disturbances than the non-depressive caregivers both before and after the LTCIS. Before LTCIS, depressive caregivers were more likely to attend to the elderly for more than 16 hours per day than their counterparts. After the LTCIS, depressive caregivers were more likely to be a spouse, to care for a frail elderly male, and less likely to be able to go out without accompanying the elderly than their counterparts. Even after the introduction of LTCIS, half of the caregivers were depressive. It is suggested that a government agency should be created to support not only the frail elderly but also their caregivers.
Collapse
|
48
|
Patient specific simulation and navigation of ventriculoscopic interventions. Stud Health Technol Inform 2007; 125:433-5. [PMID: 17377318] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
In this paper a comprehensive framework for pre-operative planning, procedural skill training, and intraoperative navigation is presented. The goal of this system is to integrate surgical simulation with surgical planning in order to improve the individual treatment of patients. Various surgical approaches and new, more complex procedures can be assessed using a safe and objective platform that will allow the physicians to explore and discuss possible risks and benefits prior to the intervention. A simulation environment extends the pre-operative planning in a natural way, as it allows for direct evaluation of the surgical approach envisioned for each case. In addition, by providing intraoperative navigation based on this simulation, surgeons can carry out the previously optimized plan with higher precision and greater confidence.
Collapse
|
49
|
Erythromycin ameliorates renal injury via anti-inflammatory effects in experimental diabetic rats. Diabetologia 2005; 48:2402-11. [PMID: 16231067 DOI: 10.1007/s00125-005-1945-6] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2004] [Accepted: 06/29/2005] [Indexed: 01/13/2023]
Abstract
AIMS/HYPOTHESIS Recent studies have shown that the inflammatory process is involved in the pathogenesis of diabetic nephropathy. Fourteen-membered ring macrolides, including erythromycin, have anti-inflammatory, as well as antibacterial effects. The aim of this study was to investigate the renoprotective effects of erythromycin in streptozotocin (STZ)-induced diabetic rats. METHODS STZ-induced diabetic rats were treated orally with erythromycin (5 mg/kg body weight) or vehicle every day for 8 weeks. To evaluate the effect of erythromycin treatment, we measured urinary albumin excretion, and examined the following in the kidney: histological changes, the expression of intercellular adhesion molecule-1 (ICAM-1), macrophage infiltration, and nuclear factor-kappa B (NF-kappaB) activity. RESULTS Erythromycin significantly reduced urinary albumin excretion without affecting blood glucose levels and blood pressure. Erythromycin also attenuated glomerular hypertrophy, mesangial expansion, macrophage infiltration and ICAM-1 expression in renal tissues. The expression of the gene encoding TGFB1 (also known as TGF-beta1), type IV collagen protein production and NF-kappaB activity in renal tissues were increased in diabetic rats and reduced by erythromycin treatment. CONCLUSIONS/INTERPRETATION Erythromycin prevented renal injuries without changes of blood glucose levels and blood pressure in experimental diabetic rats. These results suggest that the renoprotective effects of erythromycin are based on its anti-inflammatory effect via suppression of NF-kappaB activation. Modulation of microinflammation with erythromycin may provide a new approach for diabetic nephropathy.
Collapse
|
50
|
Indications for neuroendoscopic aqueductoplasty without stenting for obstructive hydrocephalus due to aqueductal stenosis. ACTA ACUST UNITED AC 2005; 48:136-41. [PMID: 16015489 DOI: 10.1055/s-2004-830265] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
OBJECTIVE Neuroendoscopic aqueductoplasty (EAP) is a curative and radical procedure for obstructive hydrocephalus due to aqueductal stenosis that re-establishes the physiological circulation of cerebrospinal fluid (CSF). We assessed the indications for safe neuroendoscopic aqueductoplasty without stenting to treat aqueductal stenosis. METHODS In the past 5 years, 6 (5.5 %) of the 110 patients with obstructive hydrocephalus due to aqueductal stenosis were judged to be suitable for EAP on the basis of the MRI features of the aqueduct and intraoperative neuroendoscopic findings from the third ventricle for the aqueductal stenosis. The remaining 104 patients were treated by neuroendoscopic third ventriculostomy. Indications for safe EAP were determined retrospectively based on the clinical features, preoperative MRI, intraoperative neuroendoscopic findings and outcome of the 6 patients who underwent EAP. RESULTS There were no deaths due to EAP. All of the patients showed improvement or resolution of their preoperative symptoms. In 5 patients, dilatation of the third ventricle and lateral ventricles diminished, and prestenotic dilatation of the aqueduct also disappeared. After an average follow-up period of 39.5 months, recurrence of aqueductal stenosis has not been observed. In one patient, there was a complication of oculomotor nerve paresis after EAP. CONCLUSIONS EAP can be considered the best surgical procedure for restoring physiological circulation of CSF in patients with obstructive hydrocephalus caused by aqueductal stenosis. However, EAP candidates must be selected very carefully using the following indications: 1) obstructive triventricular hydrocephalus with increased intracranial pressure, 2) translucent membranous stenosis or aqueduct obstruction, and 3) prestenotic dilatation of the aqueduct.
Collapse
|