1
|
DISTRACTED DRIVING IN OLDER ADULTS: PRACTICES AND ATTITUDES. Innov Aging 2017. [DOI: 10.1093/geroni/igx004.4352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
2
|
Search for clastogenic factors in the plasma of locally irradiated individuals. Radiat Res 2011; 177:298-306. [PMID: 22165823 DOI: 10.1667/rr2721.1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
In studies reported in the 1960s and in several investigations since, plasma from irradiated individuals was shown to induce chromosomal aberrations when transferred into normal blood cultures. In the present study, the aim was to investigate the occurrence of these clastogenic factors (CF) using markers representing DNA damage produced in reporter lymphocytes that are treated with plasma from locally exposed individuals. Blood plasma was obtained from clinical patients with benign conditions before and after they had received radiation to small treatment volumes. Three patient groups were studied: (I) marginal resected basal cell carcinoma, (II) painful osteoarthritis of the knee, and (III) painful tendinitis of the elbow or the heel. Patients in each treatment group obtained the same fractionated treatment regimen, ranging from a total dose of 40 Gy (8 × 5 Gy, 2 factions/week) to a very small volume (1-3.5 cm³) in group I to a total dose of 6 Gy (6 × 1 Gy, 2 fractions/week) for groups II and III (treatment volumes 800-1150 cm³ and 80-160 cm³, respectively). The presence of CF in the plasma was investigated through cytogenetic (chromosomal aberrations, micronuclei) assays and kinetics of early DNA damage (γ-H2AX foci) in reporter cells. With the experimental settings applied, local radiation exposure had no apparent effect on the induction of CF in patient plasma; no deviations in chromosomal aberrations or micronucleus or focus induction were observed in reporter cells treated with postexposure plasma with respect to pre-exposure samples when the mean values of the groups were compared. However, there was a large interindividual variation in the plasma-induced DNA-damaging effects. Steroid treatment of patients was demonstrated to be the most influential factor affecting the occurrence of plasma factors; plasma from patients treated with steroids led to significant reductions of γ-H2AX foci and reduced numbers of chromatid aberrations in reporter cells. In addition to the locally exposed patients, newly obtained plasma samples from three radiological accident victims exposed in 1994 were examined. In contrast to the patient data, a significant increase in chromosomal aberrations was induced with plasma from two accident victims.
Collapse
|
3
|
|
4
|
Low‐dose radiotherapy (LD‐RT) and the modulation of iNOS expression in adjuvant‐induced arthritis in rats. Int J Radiat Biol 2009; 79:993-1001. [PMID: 14713577 DOI: 10.1080/09553000310001636639] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
PURPOSE Low-dose radiotherapy (LD-RT) of arthritic joints applied during the peak of the acute inflammatory response improves the clinical and histomorphological development of adjuvant arthritis. The study was undertaken to investigate the cellular composition of the inflammatory infiltrate and the expression of the pro-inflammatory and anti-inflammatory enzymes, inducible nitric oxide synthase (iNOS), cyclo-oxygenase 2 (COX-2) and haem-oxygenase 1 (HO-1), in response to LD-RT. MATERIALS AND METHODS Adjuvant arthritis in female Lewis rats was induced by intradermal injection of heat-inactivated mycobacterium tuberculosis on day 0. Both arthritic hind paws were sham irradiated (group 1) or X-irradiated with either 5 x 1.0 Gy (group 2) or 5 x 0.5 Gy (group 3) from days 15 to 19 after induction (15 animals/group). On days 21 (n=12 joints/group) and 30 (n=18 joints/group), cryostat sections were analysed histologically and immunohistologically after specific staining for macrophages, iNOS, COX-2 and HO-1. RESULTS A total of 5 x 1.0 Gy or 5 x 0.5 Gy led to a significant reduction of clinical symptoms from days 21 to 29, and a highly significant reduction of cartilage and bone destruction on day 30. Macrophage-positive areas could be detected continuously throughout the periarticular infiltrate, and were slightly reduced after LD-RT on days 21 and 30. This reduction was more pronounced after 5 x 1.0 Gy. Following LD-RT, the iNOS score was reduced by about 45-50% on days 21 (p<0.05) and 30 (p<0.001). In contrast, the HO-1 score was increased by about 50% on days 21 (p=0.08) and 30 (p=0.03). CONCLUSIONS The clinically and histologically observed prevention of the progression of adjuvant arthritis after LD-RT given during the peak of the acute inflammatory response and the reduction of cartilage and bone destruction in the chronic phase appears to be related to the modulation of iNOS activity by low X-ray doses.
Collapse
|
5
|
Beta1-integrin and IL-1alpha expression as bystander effect of medium from irradiated cells: the pilot study. Acta Histochem 2003; 105:223-30. [PMID: 13677615 DOI: 10.1078/0065-1281-00710] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Bystander effects have been proposed as a third action pathway of ionising radiation besides direct and indirect effects. The purpose of the study was to investigate whether expression of interleukin-1alpha (IL-1alpha) and beta1-integrin is elevated in bystander cells as a marker for bystander effects in comparison with classical markers such as the clonogenic assay, apoptosis and the presence of micronuclei. The hybrid cell line E.A. hy.926 obtained by fusion of HUVEC cells with the epithelial cell line A 459 was irradiated with 0-5 Gy. Bystander effects were established via medium transfer at 45 min and 4 h after irradiation from irradiated to nonirradiated cell populations. In order to exclude effects of the irradiated medium itself, irradiated medium only was also used for transfer to nonirradiated cells. Then, cells were fixed at 1, 2, 6, and 24 h after irradiation or medium transport and IL-1alpha and beta1-integrin were detected and evaluated. A higher number of beta1-integrin-positive cells was observed in both irradiated and bystander cell populations than in the control group at 1 and 24 h after irradiation with 1 Gy or medium transfer. Significantly higher numbers of IL-1alpha-positive cells were found at 1, 2, and 6 h after irradiation with 1 Gy or medium transfer as well as at 2 and 6 h after irradiation with 5 Gy or medium transfer. Clonogenic survival decreased dependently on the dose in irradiated cells but did not show any significant difference between the bystander cell populations and sham-irradiated cells. The irradiated medium itself did not have any effect. It is concluded that beta1-integrin and IL-1alpha expression may serve as more sensitive markers of post-irradiation responses in bystander cell populations than the classical radiobiological markers. Moreover, overexpression of beta1-integrin and IL-1alpha may induce increased susceptibility to inflammation of bystander cells.
Collapse
|
6
|
Practical realization of massively parallel fiber-free-space optical interconnects. APPLIED OPTICS 2001; 40:2902-2908. [PMID: 18357309 DOI: 10.1364/ao.40.002902] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
We propose a novel approach to realizing massively parallel optical interconnects based on commercially available multifiber ribbons with MT-type connectors and custom-designed planar-integrated free-space components. It combines the advantages of fiber optics, that is, a long range and convenient and flexible installation, with those of (planar-integrated) free-space optics, that is, a wide range of implementable functions and a high potential for integration and parallelization. For the interface between fibers and free-space optical systems a low-cost practical solution is presented. It consists of using a metal connector plate that was manufactured on a computer-controlled milling machine. Channel densities are of the order of 100/mm(2) between optoelectronic VLSI chips and the free-space optical systems and 1/mm(2) between the free-space optical systems and MT-type fiber connectors. Experiments in combination with specially designed planar-integrated test systems prove that multiple one-to-one and one-to-many interconnects can be established with not more than 10% uniformity error.
Collapse
|
7
|
Iterative optimization of phase-only diffractive optical elements based on a lenslet array. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA. A, OPTICS, IMAGE SCIENCE, AND VISION 2000; 17:2157-2164. [PMID: 11140474 DOI: 10.1364/josaa.17.002157] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
We describe the design of Fourier-type phase-only array generators. The numerical optimization employs the Fienup algorithm, where the parageometric design of the phase retardation profile, with the form of a lenslet array, is used as the initial guess of the optimization process. This approach provides designs with high performance that can be obtained with comparatively low computing effort. This is particularly true for elements generating large spot arrays. For symmetric reconstruction fields, the optimized phase profile typically has the same symmetry as that for the reconstruction field and can be easily unwrapped.
Collapse
|
8
|
Abstract
We present the design of a planar-integrated optoelectronic vector-matrix multiplier. The inherent parallel-processing potential is fully exploited by optical implementation of multiplications and summations. Planar integration makes the free-space optical system compatible with electronic VLSI technologies. It is composed of phase-only diffractive optical elements, which implement lens and multiple-beam-splitter functions. A demonstrator version of the optical system for a matrix of size 10 x 10 was fabricated on quartz glass by means of multimask lithography and reactive ion etching. It shows low cross talk and good uniformity of the signals.
Collapse
|
9
|
Abstract
PURPOSE Substantial clinical evidence shows the efficacy of low dose radiotherapy (RT) in the treatment of painful osteoarthritis. Experimental investigations into these empirically clinical observations remain scarce. This study investigated in vivo the effects of daily 5 x 1.0 Gy versus 5 x 0.5 Gy on adjuvant induced arthritis in rats in order to explore whether there is a dose dependence of anti-inflammatory efficacy. MATERIALS AND METHODS Adjuvant arthritis in female Lewis rats was induced by intradermal injection of heat inactivated Mycobacterium tuberculosis on day 0. Both hind paws were X-irradiated daily from days 15 to 19 after induction according to four protocols (15 animals/group): group 1, 5 x 1.0 Gy (non-arthritic animals); group 2, sham-irradiated control; group 3, 5 x 1.0 Gy; group 4, 5 x 0.5 Gy. The clinical parameters arthritis score (AS), hind paw volume (HPV), body weight, and erythrocyte sedimentation rate (ESR) were determined. On days 21 and 30 histological sections of at least 12 ankle joints per group were analysed semi-quantitatively. RESULTS Local irradiation of non-arthritic rats (group 1) with 5 x 1 Gy did not induce any arthritic signs. Sham-irradiated arthritic rats (group 2) showed a full-blown arthritic syndrome. Treatment of arthritic rats with 5 x 1 Gy (group 3) or 5 x 0.5 Gy (group 4) led to a reduction of mean AS from day 21 to 29 compared with group 2 (days 27-29--group 3: p=0.037; group 4: p=0.034), with no differences in efficacy between groups 3 and 4. Concurrently, following radiation treatment there was no further increase in HPV. At the end of the observation period, this effect demonstrated a dose-dependent level of significance (days 27-29--group 3: p=0.0036; group 4: p=0.039). A significant decrease in the ESR was noted in both irradiated arthritic groups on day 21 (group 3: p=0.015; group 4: p=0.006). The histopathological analysis revealed a highly significant reduction of cartilage and bone destruction on day 30 in both irradiated groups. CONCLUSIONS This study confirms by objective criteria the anti-inflammatory efficacy of low dose RT and gives some indication for a dose dependence of its efficacy.
Collapse
|
10
|
Compact planar-integrated optical correlator for spatially incoherent signals. APPLIED OPTICS 2000; 39:759-765. [PMID: 18337950 DOI: 10.1364/ao.39.000759] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
A new, to our knowledge, approach for the planar integration of optical correlators is demonstrated. A VanderLugt-type architecture was used to allow the processing of the spatially incoherent signals of active optoelectronic smart-pixel-device arrays. In a folded optical system all passive components were implemented as a single multiple-phase-level element. The relations among the spatial resolution, the light efficiency, and the system design parameters are derived. High signal quality and low noise levels were achieved experimentally.
Collapse
|
11
|
Fabrication of microprisms for planar optical interconnections by use of analog gray-scale lithography with high-energy-beam-sensitive glass. APPLIED OPTICS 1999; 38:2986-2990. [PMID: 18319880 DOI: 10.1364/ao.38.002986] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
For an integrated free-space optical interconnection system we suggest the use of microprisms to achieve large coupling angles at low loss. Prisms were fabricated in photoresist and quartz glass by analog lithography. High-energy-beam-sensitive glass was used as the gray-tone mask. Optical testing of the prisms shows acceptable surface quality and high efficiency (95%).
Collapse
|
12
|
Planar-integrated talbot array illuminators. APPLIED OPTICS 1998; 37:5399-5407. [PMID: 18286022 DOI: 10.1364/ao.37.005399] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
We demonstrate the planar integration of Talbot array illuminators designed to generate one-dimensional spot arrays. The array illuminator basically consists of a phase grating and a cylindrical diffractive lens integrated as a single diffractive optical element onto a transparent glass substrate. We discuss various design aspects, and we focus on problems typical for planar-integrated free-space optics like the tilted optical axis of the system. Experimental results and measurements, which were obtained from planar-integrated setups fabricated as surface-relief structures on a transparent glass substrate by use of standard photolithography, are included.
Collapse
|
13
|
Diffractive optics and micro-optics: introduction to the feature issue. APPLIED OPTICS 1997; 36:4633. [PMID: 18259257 DOI: 10.1364/ao.36.004633] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
This issue of Applied Optics features 19 articles related to the fabrication and the design of diffractive and micro-optics as well as their applications. A companion feature in the Journal of the Optical Society of America A includes papers on the modeling of diffractive elements.
Collapse
|
14
|
Integrated micro-optical imaging system with a high interconnection capacity fabricated in planar optics. APPLIED OPTICS 1997; 36:4729-4735. [PMID: 18259271 DOI: 10.1364/ao.36.004729] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
An integrated free-space optical interconnection system with 2500 parallel data channels is demonstrated. The design is based on a combination of microchannel imaging and conventional imaging. A modification of the hybrid imaging configuration allows one to achieve optimized image quality over large image fields.
Collapse
|
15
|
[Regression of Yoshida sarcoma during normoxia and hypoxia after fractionated irradiation]. Strahlenther Onkol 1997; 173:141-5. [PMID: 9122854 DOI: 10.1007/bf03039271] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
PURPOSE Tumor regression is one of the most important factors determinating the tumor control probability after radiotherapy. The changes in the regression of tumors during fractionated radiotherapy and the application of different radioprotectors or radiosensitizers make render to assess their effectivity. MATERIAL AND METHOD The effect of hypoxic breathing (8.1% O2) on the tumor regression of Yoshida sarcoma was studied using rats of Wistar strain. Different fractionation schedules were used: 10 x 3 Gy, 6 x 5 Gy and 3 x 10 Gy. RESULTS No significant changes in the tumor regression after radiotherapy in any group in any time independent from respiratoric hypoxia were recorded. The tumor regression rate was significantly influenced by treatment schedule (p < 0.0005). CONCLUSIONS Our results support the hypothesis of hypoxy-radiotherapy: The acute hypoxic hypoxia, caused due the breathing of hypoxic gas mixture with 8 to 10% oxygen, did not influence the radiation induced tumor regression in animal experiment. For this criterium no protection can be shown. The influence of hypoxy-radiotherapy on the local tumor control is necessary to evaluate in further experiments.
Collapse
|
16
|
[Reoxygenation in Yoshida sarcoma during different fractionated radiotherapy]. Strahlenther Onkol 1996; 172:619-25. [PMID: 8975393] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
PURPOSE Tumor reoxygenation is one of the most important factors determining the tumor control probability after radiotherapy. In experimental studies reoxygenation has been measured preferably after single dose irradiation. Only few data exist about changes in the hypoxic tumor fraction during fractionated radiotherapy. MATERIAL AND METHODS The changes in the pO2 during fractionated radiotherapy were studied in Yoshida sarcoma transplanted to Wistar rats. Tissue oxygenation was assessed using a polarographic electrode system at the beginning, in the middle and at the end of radiation therapy. Different fractionation schedules were used: 10 x 3 Gy, 6 x 5 Gy and 3 x 10 Gy. RESULTS In the statistical analysis significant changes emerged in the mean, median, 10%-percentile and 0 to 2.5 mm Hg and 0 to 5.0 mm Hg values dependent on time. The tumors were significantly more hypoxic at the end of therapy. This trend became more pronounced with decreasing dose per fraction. CONCLUSIONS The Yoshida sarcoma has no effective reoxygenation during fractionated radiotherapy.
Collapse
|
17
|
[Hypoxyradiotherapy: changes in the oxygen partial pressure distribution in the tumor and in the healthy tissue under acute respiratory hypoxia]. Strahlenther Onkol 1996; 172:427-33. [PMID: 8765345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
PURPOSE Based on the oxygen effect a new therapeutic modality has been developed to protect healthy tissues while breathing hypoxic gas mixture during irradiation. MATERIAL AND METHODS The effect of breathing hypoxic gas mixture (8.1% O2) on pO2 in Yoshida sarcoma and muscle was studied using rats of Wistar strain. Different fractionation schedules were used: 10 x 3 Gy, 6 x 5 Gy and 3 x 10 Gy. Tissue oxygenation was assessed with a polarographic electrode system. RESULTS The median pO2 in Yoshida sarcoma was 10 mm Hg. 21% of pO2-values were lower than 5 mm Hg. During breathing of hypoxic gas mixture no significant changes in median tumor pO2 or radiobiologic hypoxic values (< or = 5 mm Hg) were recorded. The median pO2 in muscle was 30 mm Hg. During breathing of gas hypoxic mixture a significant decrease of the median to the value 12 mm Hg and an increase of the radiobiologic hypoxic values (p < 0.00001) were observed. The changes of pO2-values were constant independent from fractionation. CONCLUSIONS Between tumor and healthy tissue exists a significant difference regarding changes in the radiobiologic fraction during breathing of hypoxic gas mixture. This fact explains the experimental and clinical experience, that the breathing hypoxic gas mixture protects the healthy tissue without changes in the radiosensibility of chronic hypoxic tumor tissue.
Collapse
|
18
|
Packaging considerations for planar optical interconnection systems. APPLIED OPTICS 1994; 33:1391-1397. [PMID: 20862165 DOI: 10.1364/ao.33.001391] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
We discuss various aspects of building an integrated optoelectronic system that is based on the concept of planar optics. A particular optical interconnection system has been fabricated and demonstrated. It provides parallel interconnections with 1024 optical channels that could be useful as an optical backplane in an optoelectronic multichip module. We consider the design and the fabrication of the optical system, schemes for the hybrid integration with optoelectronic device arrays, and the thermal management of an integrated system. The proposed hybrid integration scheme is based on mature technologies such as thermal anodic bonding and flip-chip bonding. Possibilities for efficient heat sinking are described.
Collapse
|
19
|
Integrated planar optical imaging systems with high interconnection density. OPTICS LETTERS 1993; 18:1594-1596. [PMID: 19823456 DOI: 10.1364/ol.18.001594] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
|
20
|
Design and fabrication of high-efficiency beam splitters and beam deflectors for integrated planar micro-optic systems. APPLIED OPTICS 1993; 32:2494-2501. [PMID: 20820409 DOI: 10.1364/ao.32.002494] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
High-frequency gratings with rectangular-groove profiles are used to generate high-efficiency beam splitters and beam deflectors. The effects of the grating design parameters, i.e., period, groove depth, duty cycle, number of phase levels, and polarization state (TE and TM) of the incoming signal, are considered. The case of the binary beam splitter grating is analyzed by using rigorous electromagnetic grating analysis. Fabrication techniques are presented in which three different lithographic techniques are considered (optical contact, deep-UV stepper reduction, and electron-beam direct write). Experimental results of 97% efficiency for the beam splitter grating and up to 80% for the beam deflector grating are reported.
Collapse
|
21
|
Precise alignment through thick wafers using an optical copying techniquev. OPTICS LETTERS 1992; 17:390-392. [PMID: 19784337 DOI: 10.1364/ol.17.000390] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Submicrometer alignment of two mask patterns on the top and the bottom surface of a thick glass substrate is possible by using optical copying. The optical copying step transfers an alignment pattern from one surface to the other by shadow casting or Fresnel propagation. In a demonstration experiment, the alignment between the two surfaces of a 3-mm-thick quartz glass substrate was achieved with a precision of 0.5-0.7 microm.
Collapse
|
22
|
Optical interconnects using top-surface-emitting microlasers and planar optics. APPLIED OPTICS 1992; 31:592-597. [PMID: 20720653 DOI: 10.1364/ao.31.000592] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
Optical interconnections made using two-dimensional arrays of top-surface-emitting microlasers and integrated free-space optics are discussed for use in chip-to-chip communications. A demonstration setup with a 2 x 2 array of lasers is presented. System parameters, such as light efficiency, the number of data channels, thermal effects, power requirements, and the issue of hybrid integration of laser chips with passive optics, are considered.
Collapse
|
23
|
Abstract
Lenslet arrays can be used as phase gratings, having many diffraction orders with equal intensity. Applications are multiple imaging and illumination of arrays of optical or optoelectronic devices in digital optics. The homogeneity of the intensities within the array can be improved by using field lenslets. The basic theory as well as experiments with diffractive and with graded index lenses are shown.
Collapse
|
24
|
Abstract
We demonstrate an optical system that splits one laser beam into an array of N x N equal-intensity beams. It consists of a grating and a diffractive lens, which are integrated on one side of a single planar quartz-glass substrate. The grating and the lens are fabricated with multiple discrete phase levels by using photolithography and thin-film deposition.
Collapse
|
25
|
Abstract
A planar version of a 4f imaging system is described where the input object and the lenses are integrated on one side of a single quartz glass substrate. The lenses were implemented as diffractive lenses with four discrete phase levels.
Collapse
|
26
|
Two-dimensional array of diffractive microlenses fabricated by thin film deposition. APPLIED OPTICS 1990; 29:931-936. [PMID: 20562938 DOI: 10.1364/ao.29.000931] [Citation(s) in RCA: 29] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
A 2-D array of 10 x 10 diffractive lenslets was fabricated and tested. Each lenslet has a rectangular aperture and a size of 1.5 mm x 1.5 mm. The focal length of each lenslet is 47 mm. The array was produced by depositing thin films of silicon monoxide on a quartz glass substrate and by using photolithographic techniques. The performance of the lenslets is based on the diffraction of light at a Fresnel zone plate (FZP). The FZP pattern was implemented as a phase structure with eight discrete levels. The diffraction efficiency was measured to be 91%.
Collapse
|
27
|
|
28
|
Abstract
Crossover networks are introduced as a new type of interconnection network for applications in optical computing, optical switching, and signal processing. Crossover networks belong to the class of multistage interconnection network. Two variations are presented, the half-crossover network and the full crossover network. An optical system which implements both networks is proposed and demonstrated. Crossover networks can be implemented using the full space-bandwidth product of the optical system with minimal loss of light. It is shown that crossover networks are isomorphic to other multistage networks such as the Banyan and perfect shuffle.
Collapse
|
29
|
Abstract
Regular free-space interconnects such as the perfect shuffle and banyan provided by beam splitters, lenses, and mirrors connect optical logic gates arranged in 2-D arrays. An algorithmic design technique transforms arbitrary logic equations into a near-optimal depth circuit. Analysis shows that an arbitrary interconnect makes little or no improvement in circuit depth and can even reduce throughput. Gate count is normally higher with a regular interconnect, and we show cost bounds. We conclude that regularly interconnected circuits will have a higher gate count compared with arbitrarily interconnected circuits using the design techniques presented here and that regular free-space interconnects are comparable with arbitrary interconnects in terms of circuit depth and are preferred to arbitrary interconnects for maximizing throughput.
Collapse
|
30
|
[Influence of hypoxia on the hematologic radiation response following ionizing whole body radiation in dogs]. RADIOBIOLOGIA, RADIOTHERAPIA 1980; 21:591-599. [PMID: 7208848] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
|
31
|
[Protective action of total gas hypoxia in the local skin irradiation of large animals]. MEDITSINSKAIA RADIOLOGIIA 1979; 24:3-8. [PMID: 502778] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
32
|
[A visual procedure for the detection of the radiation response of the skin of pigs and dogs (author's transl)]. RADIOBIOLOGIA, RADIOTHERAPIA 1979; 20:222-7. [PMID: 472191] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
33
|
[Modification of the effect of radiation on pig skin using gaseous hypoxia (author's transl)]. RADIOBIOLOGIA, RADIOTHERAPIA 1979; 20:128-35. [PMID: 461726] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
34
|
[Modification of radiosensibility of transplanted tumours by preirradiation with low doses (author's transl)]. RADIOBIOLOGIA, RADIOTHERAPIA 1978; 19:588-92. [PMID: 740882] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
35
|
[Method for the photometric determination of radiation responses of the skin (author's transl)]. RADIOBIOLOGIA, RADIOTHERAPIA 1978; 19:495-501. [PMID: 734089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|