1
|
Demographic factors associated with myopia knowledge, attitude and preventive practices among adults in Ghana: a population-based cross-sectional survey. BMC Public Health 2023; 23:1712. [PMID: 37667219 PMCID: PMC10476336 DOI: 10.1186/s12889-023-16587-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2022] [Accepted: 08/22/2023] [Indexed: 09/06/2023] Open
Abstract
PURPOSE Knowledge, positive attitude and good preventive practices are keys to successful myopia control, but information on these is lacking in Africa. This study determined the KAP on myopia in Ghana. METHODS This was a population-based cross-sectional survey conducted among adults (aged 18 years and older) living across 16 regions of Ghana between May and October 2021. Data on socio-demographic factors (sex, age, gender, level of education, working status, type of employment, monthly income, and region of residence), respondents' awareness, and knowledge, attitude and preventive practices (KAP) about myopia were collected. Composite and mean scores were calculated from eleven knowledge (total score = 61), eight attitude (48), and nine preventive practice items (33). Differences in mean scores were assessed using one-way analysis of variance (ANOVA) and standardized coefficients (β) with 95% confidence intervals (CI), using multiple linear regression to determine the associations between the dependent (KAP) and demographic variables. RESULTS Of the 1,919 participants, mean age was 37.4 ± 13.4 years, 42.3% were aged 18-30 years, 52.6% were men, 55.8% had completed tertiary education, and 49.2% had either heard about myopia, or accurately defined myopia as short sightedness. The mean KAP scores were 22.9 ± 23.7, 33.9 ± 5.4, and 22.3 ± 2.8, respectively and varied significantly with many of the demographic variables particularly with age group, region, marital status, and type of employment. Multiple linear regression analyses revealed significant associations between region of residence and knowledge (β =-0.54, 95%CI:-0.87, -0.23, p < 0.001), attitude (β =-0.24, 95%CI:-0.35,-0.14, p < 0.001) and preventive practices (β = 0.07, 95%CI: 0.01, 0.12, p = 0.015). Preventive practices were also associated with type of employment (self-employed vs employee: β = 0.25, 95%CI: 0.15, 4.91, p < 0.05). Knowledge scores were significantly higher in those who lived in the Greater Accra (39.5 ± 18.5) and Eastern regions (39.1 ± 17.5) and lower among those who lived in the Upper West region (6.4 ± 15.6). Government employees and those with tertiary education had significantly higher mean knowledge scores compared with non-government employees (β = 4.56, 95%CI 1.22, 7.89, p = 0.007), and those with primary/no education (β = 18.35, 95%CI: 14.42, 22.27, p < 0.001). CONCLUSION Ghanaian participants had adequate knowledge of myopia but showed poor attitude and low preventive practices, which varied significantly between regions and were modified by socio-demographic factors. Further research into how education can be used to stimulate Ghanaians' engagement in preventive practices is needed.
Collapse
|
2
|
Profiling and factors associated with glaucoma diagnostic practice in sub-Saharan Africa-a cross sectional study of Nigerian and Ghanaian optometrists. BMC Ophthalmol 2023; 23:351. [PMID: 37553655 PMCID: PMC10410918 DOI: 10.1186/s12886-023-03083-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Accepted: 07/14/2023] [Indexed: 08/10/2023] Open
Abstract
BACKGROUND Ghana and Nigeria are the two countries in Africa that currently run the Doctor of Optometry (OD) program in sub-Saharan Africa (SSA). Optometrists in these countries are licensed to provide glaucoma care. Despite the clinically relevant practice guidelines for glaucoma, there is no data on the practice patterns for glaucoma eye care in SSA, a region with the highest prevalence of glaucoma. This study aimed to profile glaucoma diagnosis adherence to practice guidelines among optometrists in two neighbouring anglophone countries (Nigeria and Ghana). METHODS A web-based cross-sectional survey of practising optometrists was conducted in both countries. Each country data was weighted to reflect the total number of licensed and practising optometrists at the time of this survey. Descriptive analyses were performed against demography and practice factors using survey commands to adjust for sampling weights when estimating confidence intervals (CI) around prevalence estimates. Simple and multiple logistic regression analyses were performed to identify factors associated with glaucoma diagnosis. RESULTS A total of 493 optometrists (238, 48.3% and 255, 51.7%) from Ghana and Nigeria respectively, responded to the survey-the first to document and compare the glaucoma diagnostic criteria between optometrists in Ghana and Nigeria. More Ghanaian than Nigerian optometrists diagnosed glaucoma and over 90% in both countries reported that they frequently performed either tonometry, visual field testing, or fundus examination during glaucoma diagnosis. Ghanaian optometrists were significantly more likely to diagnose glaucoma than Nigerian optometrists (adjusted odd ratio, AOR = 6.15, 95%CI:1.63-23.15, P = .007). Optometrists who have practiced for more than 10 years (AOR = 7.04; 95%CI:1.74-28.47, P = .006) and private practice optometrists (AOR = 3.33; 95%CI:1.13-9.83, P = .03) were more likely to diagnose glaucoma. CONCLUSIONS The study provides information for evaluating glaucoma assessment for optometrists in both countries. Optometrists in both countries are reasonably well-equipped to diagnose glaucoma and are practicing at an adequate level, but with room for improvement.
Collapse
|
3
|
Trends in myopia management attitudes and strategies in clinical practice: Survey of eye care practitioners in Africa. Cont Lens Anterior Eye 2023; 46:101597. [PMID: 35428590 DOI: 10.1016/j.clae.2022.101597] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2021] [Revised: 04/04/2022] [Accepted: 04/08/2022] [Indexed: 01/18/2023]
Abstract
PURPOSE There remains a lack of information on the perception and adoption of myopia control strategies among African eye care practitioners (ECPs). This study provides an African perspective to similar previous studies conducted in other parts of the world. METHODS A self-administered survey in English and French was distributed to ECPs across Africa. The items on the questionnaire assessed their level of concern about the increasing prevalence of paediatric myopia, perceived efficacy, opinions on, and adoption of various myopia management modalities. RESULTS Responses were obtained from 330 ECPs working in 23 African countries. Respondents were highly concerned about the increasing prevalence of paediatric myopia in their clinic (median 8/10) and perceived approved myopia control soft contact lenses as the most effective at slowing myopia progression (mean perceived reduction in myopia progression ± SD; 53.9 ± 27.1%), followed by single vision spectacles (53.1 ± 30.9%), and orthokeratology (52.8 ± 28.0%). Multifocal soft contact lenses (40.4 ± 25.8%) and pharmaceutical agents such as topical atropine drops (39.5 ± 27.1%) were perceived as least effective in slowing myopia progression. Although ECPs reported being aware of various myopia control strategies, they still mainly prescribed single vision spectacles to a large proportion (64.3 ± 29.9%) of young progressing myopes. Nearly one-third (27%) of ECPs who prescribed single vision lenses stated they were concerned about the cost implications to patients. Other reported concerns included safety of, and inadequate information about myopia control options. CONCLUSIONS African ECPs continue to prescribe single vision lenses for progressing myopes despite being aware of the various myopia control options. Practitioners' perceptions of the efficacy of several modalities to slow myopia progression do not align with the current best evidence. Clear practice guidelines and continuing education on myopia control are warranted to inform and guide the management of myopic patients in Africa.
Collapse
|
4
|
Correction to: A systematic review of diabetes risk assessment tools in sub-Saharan Africa. Int J Diabetes Dev Ctries 2022. [DOI: 10.1007/s13410-022-01062-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
|
5
|
Effects of postural changes on measured intraocular pressure and repeatability of PT-100 tonometer and agreement with applanation and indentation tonometry. AFRICAN VISION AND EYE HEALTH 2022. [DOI: 10.4102/aveh.v81i1.691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
|
6
|
A Systematic Review of Current Teleophthalmology Services in New Zealand Compared to the Four Comparable Countries of the United Kingdom, Australia, United States of America (USA) and Canada. Clin Ophthalmol 2021; 15:4015-4027. [PMID: 34675470 PMCID: PMC8500493 DOI: 10.2147/opth.s294428] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Accepted: 08/18/2021] [Indexed: 12/20/2022] Open
Abstract
Background Over 700,000 New Zealanders (NZ), particularly elderly and Māori, live without timely access to specialist ophthalmology services. Teleophthalmology is a widely recognised tool that can assist in overcoming resource and distance barriers. Teleophthalmology gained unprecedented traction in NZ during the COVID-19 pandemic and subsequent lockdown. However, its provision is still limited and there are equity issues. The aim of this study was to conduct a systematic review identifying, describing and contrasting teleophthalmology services in NZ with the comparable countries of Australia, USA, Canada and the United Kingdom. Methods The electronic databases Embase, PubMed, Web of Science, Google Scholar and Google were systemically searched using the keywords: telemedicine, ophthalmology, tele-ophthalmology/teleophthalmology. The searches were filtered to the countries above, with no time constraints. An integrative approach was used to synthesise findings. Results One hundred and thirty-two studies were identified describing 90 discrete teleophthalmology services. Articles spanned from 1997 to 2020. Models were categorised into general eye care (n=21; 16%); emergency/trauma (n=6; 4.5%); school screening (n=25; 19%); artificial intelligence (AI) (n=23; 18%); and disease-specific models of care (MOC) (n=57; 43%). The most common diseases addressed were diabetic retinopathy (n=23; 17%); retinopathy of prematurity (n=9; 7%); and glaucoma (n=8; 6%). Programs were mainly centred in the US (n=72; 54.5%), followed by the UK (n=29; 22%), then Canada (n=16; 12%), Australia (n=13; 10%), with the fewest identified in NZ (n=3; 2%). Models generally involved an ophthalmologist consultative service, remote supervision and triaging. Most models involved local clinicians transmitting fed-forward or live images. Conclusion Teleophthalmology will likely play a crucial role in the future of eye care. COVID-19 has offered a unique opportunity to observe the use of teleophthalmology services globally. Feed-forward and, increasingly, live-based teleophthalmology services have demonstrated feasibility and cost-effectiveness in similar countries internationally. New Zealand’s teleophthalmology services, however, are currently limited. Investing in strategic partnerships and technology at a national level can advance health equities in ophthalmic care.
Collapse
|
7
|
A comparison of postural and diurnal variations in intraocular pressure using the iCare rebound tonometer and Perkins applanation tonometer in admitted adults in Kenya. AFRICAN VISION AND EYE HEALTH 2021. [DOI: 10.4102/aveh.v80i1.617] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
Abstract
Background: Elevated intraocular pressure (IOP) remained the most important known risk factor for glaucoma.Aim: To compare the postural and diurnal IOP variations using the iCare rebound tonometer (RT) and Perkins applanation tonometer (PAT).Setting: Kakamega County Hospital, Kenya.Methods: Elevated intraocular pressure measurements were taken by two (masked) examiners with two devices in the morning (06:00–09:00), midday (12:00–15:00) and evening (18:00–21:00), in the sitting followed by supine positions in one randomly selected eye of 24 oculo-visual healthy hospital-admitted patients. Effects of the time of the day and position of the body within and between devices were analysed with the Statistical Package for Social Sciences.Results: The mean IOP measured by the RT ranged from 6 mmHg to 24 millimetres of mercury (mmHg) in the sitting position and from 10 mmHg to 26 mmHg in the supine position. The mean IOP measured using PAT ranged from 6 mmHg to 21 mmHg in the sitting position and from 8 mmHg to 24 mmHg in the supine position. The IOP measured by both devices significantly varied with position (p 0.05). Perkins applanation tonometer on average gave a significantly higher IOP (1.7 mmHg [p = 0.003] and 1.3 mmHg [p = 0.034]) at 06:00 compared to that at 12:00 and 18:00, respectively. The IOP readings with the RT were on average 2.2 mmHg and 3.0 mmHg higher at 06:00 compared to that at 12:00 and 18:00, respectively (p 0.0005).Conclusion: Significant reductions were observed in postural and diurnal IOPs in the sitting positions and in the afternoon, respectively. Diurnal IOP variations were slightly higher when measured by RT compared to when measured by PAT.
Collapse
|
8
|
|
9
|
Morphological alterations of the cornea following crosslinking treatment (CXL). Clin Anat 2021; 34:859-866. [PMID: 33580896 DOI: 10.1002/ca.23728] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Revised: 01/11/2021] [Accepted: 02/05/2021] [Indexed: 12/13/2022]
Abstract
INTRODUCTION Corneal crosslinking (CXL) has revolutionized the treatment of keratoconus during the past decade. In the present study, the morphological changes in the corneal collagen fibrils (CFs) following crosslinking treatment are described. MATERIALS AND METHODS Ten pairs of porcine and rabbit corneas were retrieved. In each pair, one cornea was the control and the other underwent CXL treatment. The central corneal thickness (CCT) was measured before and after CXL treatment. Each treated and control cornea was examined with light microscopy and by transmission electron microscopy. RESULTS (a) The mean CCT was significantly reduced following treatment. (b) CFs were more closely packed in the anterior region and loosely packed in the posterior region. (c) CF diameter increased significantly in the anterior and intermediate regions but declined gradually towards the deeper regions. (d) There was a statistically significant decrease in the interfibrillar distance over the different regions of the cornea, except for the posterior region in porcine corneas, where there was no change. (e) The distance between adjacent collagen lamellae was significantly decreased in all regions of treated rabbit corneas. There was no change in porcine corneas. CONCLUSION CXL treatment resulted in increased the CF diameter and decreased interfibrillar distance in the anterior and intermediate regions, while its effects on the posterior region differed among species. The effect on interlamellar distance was more prominent in the rabbit model than the porcine model. CXL treatment stiffened the corneas by increasing CF diameter and decreasing interfibrillar distance in both rabbit and pig corneas.
Collapse
|
10
|
<p>Dynamic Pupillometry in Type 2 Diabetes: Pupillary Autonomic Dysfunction and the Severity of Diabetic Retinopathy</p>. Clin Ophthalmol 2020; 14:3923-3930. [PMID: 33244218 PMCID: PMC7683350 DOI: 10.2147/opth.s279872] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2020] [Accepted: 10/28/2020] [Indexed: 01/27/2023] Open
|
11
|
Focus on undergraduate ophthalmology teaching, survey of final year medical students in a New Zealand medical school. Clin Exp Ophthalmol 2020; 48:1001-1002. [DOI: 10.1111/ceo.13796] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Accepted: 05/24/2020] [Indexed: 11/26/2022]
|
12
|
The Detection of Spontaneous Venous Pulsation with Smartphone Video Ophthalmoscopy. Clin Ophthalmol 2020; 14:331-337. [PMID: 32099318 PMCID: PMC7006856 DOI: 10.2147/opth.s238897] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2019] [Accepted: 01/13/2020] [Indexed: 11/23/2022] Open
Abstract
Purpose Spontaneous venous pulsation (SVP) has a high negative predictive value for raised intracranial pressure and is a useful sign when assessing patients with headache. The objective was to determine if smartphone-based video ophthalmoscopy can detect SVP. Patients and Methods In total 233 patients and 291 eyes were recruited from the Dunedin Hospital eye clinic from July to November 2018. Patients were examined by a clinician and graded for SVP with a slit lamp and 78 Dioptre lens. Videos were taken with a smartphone ophthalmoscope and graded by two separate clinicians blinded to the slit lamp findings. Results Only 272 eyes of 215 patients were included, as others failed in the inclusion criteria for overall video quality. Sensitivity was calculated as how likely the presence of SVP on video was indicative of the presence of SVP on slit lamp. Sensitivity was 84.77% for Observer 1, with 128 videos graded as positive for SVP on video ophthalmoscopy of the 151 identified as positive on slit lamp examination. Sensitivity was 76.82% for Observer 2 with 116 videos correctly identified. The false positive rate was calculated as the number of videos graded positive for SVP that had been graded as negative on slit lamp examination. This was 10.74% for observer 1 and 31.40% for observer 2. Conclusion This study demonstrates that SVP is detected by video ophthalmoscopy. This may be a useful triage, telemedicine and referral tool to be used for patients with headache in a primary care setting.
Collapse
|
13
|
Lower eyelid excursion: A functional and cosmetically relevant parameter in the treatment of lower eyelid retraction. J Plast Reconstr Aesthet Surg 2018; 72:310-316. [PMID: 30482535 DOI: 10.1016/j.bjps.2018.10.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2018] [Revised: 09/08/2018] [Accepted: 10/28/2018] [Indexed: 10/28/2022]
Abstract
The purpose of this study was to assess and quantify lower lid excursion following repair of lower lid retraction. In this retrospective cohort study, a case review of patients who had undergone ear cartilage grafting for lower lid retraction was undertaken. Surgical correction involved the placement of autologous cartilage between the tarsal plate and lower lid retractors. Measurements taken preoperatively and postoperatively were the marginal reflex 2 (MRD2) and the lower scleral show (LSS). The lower lid excursion on downgaze (LLE) was measured only postoperatively with a comparison made between operated eyes and control eyes. Thirteen eyelids of 10 patients were included in the study. Preoperatively, MRD-2 ranged from 4 to 8 mm (6.5 ± 1.5 mm) - mean ± SD. Postoperatively, MRD-2 ranged from 4 to 6 mm (5.1 ± 0.7 mm). The difference in mean MRD2 was statistically significant (p < 0.05). Preoperatively, LSS ranged from 0 to 5 mm (2.5 ± 1.6 mm). Postoperatively, LSS ranged from 0-1 mm (0.1 ± 0.3 mm). The difference in mean LSS was statistically significant (p < 0.01). Postoperatively, all lower eyelids achieved movement on downgaze. On the operated eyes, the eyelid excursion ranged from 2 to 5 mm (3.1 ± 1.0 mm) on downgaze. On the nonoperated (control) eyes (where the operations were not performed bilaterally), the eyelid excursion ranged from 1 to 4 mm (2.8 ± 1.2 mm). There was no statistically significant difference in the lid excursion of operated and nonoperated eyes (p > 0.05). It is possible to correct lower lid retraction in both primary and secondary positions of gaze if an appropriate surgical technique is employed.
Collapse
|
14
|
Development of an artificial intelligence system to classify pathology and clinical features on retinal fundus images. Clin Exp Ophthalmol 2018; 47:484-489. [PMID: 30370587 DOI: 10.1111/ceo.13433] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2018] [Revised: 09/12/2018] [Accepted: 10/05/2018] [Indexed: 12/30/2022]
Abstract
IMPORTANCE Artificial intelligence (AI) algorithms are under development for use in diabetic retinopathy photo screening pathways. To be clinically acceptable, such systems must also be able to classify other fundus abnormalities and clinical features at the point of care. BACKGROUND We aimed to develop an AI system that can detect several fundus pathologies and report relevant clinical features. DESIGN Convolutional neural network training with retrospective data set. PARTICIPANTS Colour fundus photos were obtained from publicly available fundus image databases. METHODS Images were uploaded to a web-based AI platform for training and validation of AI classifiers. Separate classifiers were created for each fundus pathology and clinical feature. MAIN OUTCOME MEASURES Accuracy, sensitivity, specificity and area under receiver operating characteristic curve (AUC) for each classifier. RESULTS We obtained 4435 images from publicly available fundus image databases. AI classifiers were developed for each disease state above. Although statistical performance was limited by the small sample size, average accuracy was 89%, average sensitivity was 75%, average specificity was 89% and average AUC was 0.58. CONCLUSION AND RELEVANCE This study is a proof-of-concept AI system that could be implemented within a diabetic photo-screening pathway. Performance was promising but not yet at the level that would be required for clinical application. We have shown that it is possible for clinicians to develop AI classifiers with no previous programming or AI knowledge, using standard laptop computers.
Collapse
|
15
|
Current perspectives on corneal collagen crosslinking (CXL). Graefes Arch Clin Exp Ophthalmol 2018; 256:1363-1384. [PMID: 29623463 DOI: 10.1007/s00417-018-3966-0] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2017] [Revised: 02/20/2018] [Accepted: 03/23/2018] [Indexed: 12/13/2022] Open
Abstract
Corneal collagen crosslinking has revolutionized the treatment of keratoconus and post-refractive corneal ectasia in the past decade. Corneal crosslinking with riboflavin and ultraviolet A is proposed to halt the progression of keratectasia. In the original "Conventional Dresden Protocol" (C-CXL), the epithelium is removed prior to the crosslinking process to facilitate better absorption of riboflavin into the corneal stroma. Studies analyzing its short- and long-term outcomes revealed that although there are inconsistencies as to the effectiveness of this technique, the advantages prevail over the disadvantages. Therefore, corneal crosslinking (CXL) is widely used in current practice to treat keratoconus. In an attempt to improve the visual and topographical outcomes of C-CXL and to minimize time-related discomfort and endothelial-related side effects, various modifications such as accelerated crosslinking and transepithelial crosslinking methods have been introduced. The comparison of outcomes of these modified techniques with C-CXL has also returned contradictory results. Hence, it is difficult to clearly identify an optimal procedure that can overcome issues associated with the CXL. This review provides an up-to-date analysis on clinical and laboratory findings of these popular crosslinking protocols used in the treatment of keratoconus. It is evident from this review that in general, these modified techniques have succeeded in minimizing the immediate complications of the C-CXL technique. However, there were contradictory viewpoints regarding their effectiveness when compared with the conventional technique. Therefore, these modified techniques need to be further investigated to arrive at an optimal treatment option for keratoconus.
Collapse
|
16
|
Clinical evaluation of two types of intracorneal ring segments (ICRS) for keratoconus. Int Ophthalmol 2016; 37:1185-1198. [DOI: 10.1007/s10792-016-0385-2] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2015] [Accepted: 10/22/2016] [Indexed: 11/25/2022]
|
17
|
Effectiveness of in-office blood pressure measurement by eye care practitioners in early detection and management of hypertension. Int J Ophthalmol 2015; 8:612-21. [PMID: 26086018 DOI: 10.3980/j.issn.2222-3959.2015.03.32] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2014] [Accepted: 07/29/2014] [Indexed: 11/02/2022] Open
Abstract
AIM To investigate the number of hypertensive patients, the optometrist is able to identify by routinely taking blood pressure (BP) measurements for patients in "at-risk" groups, and to sample patients' opinions regarding in-office BP measurement. Many of the optometrists in Saudi Arabia practice in optical stores. These stores are wide spread, easily accessible and seldom need appointments. The expanding role of the optometrist as a primary health care provider (PHCP) and the increasing global prevalence of hypertension, highlight the need for an integrated approach towards detecting and monitoring hypertension. METHODS Automated BP measurements were made twice (during the same session) at five selected optometry practices using a validated BP monitor (Omron M6) to assess the number of patients with high BP (HBP) -in at-risk groups-visiting the eye clinic routinely. Prior to data collection, practitioners underwent a two-day training workshop by a cardiologist on hypertension and how to obtain accurate BP readings. A protocol for BP measurement was distributed and retained in all participating clinics. The general attitude towards cardiovascular health of 480 patients aged 37.2 (±12.4)y and their opinion towards in-office BP measurement was assessed using a self-administered questionnaire. RESULTS A response rate of 83.6% was obtained for the survey. Ninety-three of the 443 patients (21.0%) tested for BP in this study had HBP. Of these, (62 subjects) 66.7% were unaware of their HBP status. Thirty of the 105 subjects (28.6%) who had previously been diagnosed with HBP, still had HBP at the time of this study, and only 22 (73.3%) of these patients were on medication. Also, only 25% of the diagnosed hypertensive patients owned a BP monitor. CONCLUSION Taking BP measurements in optometry practices, we were able to identify one previously undiagnosed patient with HBP for every 8 adults tested. We also identified 30 of 105 previously diagnosed patients whose BP was poorly controlled, twenty-two of whom were on medication. The patients who participated in this study were positively disposed toward the routine measurement of BP by optometrists.
Collapse
|
18
|
|
19
|
Factors influencing Saudi Arabian optometry candidates' career choices and institution of learning. Why do Saudi students choose to study optometry? Clin Exp Optom 2014; 97:442-9. [PMID: 25082438 DOI: 10.1111/cxo.12182] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2013] [Revised: 04/10/2014] [Accepted: 04/12/2014] [Indexed: 11/28/2022] Open
Abstract
BACKGROUND Optometry is a primary health-care profession (PHCP) and this study aimed to elucidate the factors influencing the choice of optometry as a career for Saudi students, the students' perceptions of optometry and the effect of gender. METHODS Two hundred and forty-seven students whose average age was 21.7 ± 1.5 (SD) years and who are currently enrolled in two colleges of optometry in Saudi Arabia--King Saud University (KSU) and Qassim University (QU)--completed self-administered questionnaires. The survey included questions concerning demography, career first choice, career perception and factors influencing career choices. RESULTS The response rate was 87.6 per cent and there were 161 male (64.9 per cent) students. Seventy-nine per cent of the participants were from KSU (males and females) and 20.6 per cent were from QU (only males). Seventy-three per cent come from Riyadh and 19 per cent are from Qassim province. Regarding the first choice for their careers, the females (92 per cent) were 0.4 times more likely (p = 0.012) to choose optometry than males (78.3 per cent). The males were significantly more likely to be influenced by the following factors: the Doctor of Optometry (OD) programs run at both universities, good salary and prospects (p < 0.05, for all). The women were significantly less likely to be influenced by another individual (p = 0.0004). Generally, more than two-thirds of the respondents viewed the desire to help others, professional prestige and the new OD programs as the three most influential factors in opting for a career in optometry. CONCLUSION Females were more likely to opt for a career in optometry and males were more likely to be influenced by the new OD programs, good salary and job prospects. Service provision to others in the community was a primary motivation to opt for a career in optometry among young Saudis.
Collapse
|
20
|
Prevalence, use and sale of contact lenses in Saudi Arabia: Survey on university women and non-ophthalmic stores. Cont Lens Anterior Eye 2014; 37:185-90. [DOI: 10.1016/j.clae.2013.10.001] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2013] [Revised: 09/22/2013] [Accepted: 10/01/2013] [Indexed: 11/17/2022]
|
21
|
Assessing the role of optometrists in the control of systemic hypertension in Saudi Arabia. ACTA ACUST UNITED AC 2013; 7:305-16. [PMID: 23582875 DOI: 10.1016/j.jash.2013.03.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2013] [Revised: 02/28/2013] [Accepted: 03/04/2013] [Indexed: 12/16/2022]
Abstract
The low level of awareness, treatment, and control of systemic hypertension is a global problem, but it is much more serious in Saudi Arabia. This study examines the contribution made by Saudi optometrists in detection and management of patients with systemic hypertension. We surveyed a sample of 250 optometrists practicing in Saudi Arabia to evaluate the level of knowledge and awareness of their role in combating systemic hypertension. A 48.4% response rate was obtained from practicing optometrists. Of those responding, optometrists were very positive towards the use of blood pressure (BP) monitors in optometric practice on a routine basis. Forty-six percent of the optometrists had access to a BP monitor, and about 93% of these respondents actually used the monitors during clinic consultations. Automated monitors were the most common (54%). Fifty-one percent and 49% of the optometrists reported that they did routinely question their patients about high BP and about their current BP medications, respectively. The less frequently asked question concerned the cholesterol level of the patient (21%). The tests most widely used by the optometrists while examining hypertensive patients was direct ophthalmoscopy with red free filter (56%) and the least was binocular indirect ophthalmoscopy (21%). Optometrists were more likely to refer patients suspected of systemic hypertension on the basis of elevated BP (74%) and presence of retinal hemorrhages (72%), but were less likely to refer patients with changes in arteriolar reflex (41%). The opinions were very positive towards the routine monitoring of BP within the Saudi optometry profession, as optometrists indicated that they had time within an eye examination to measure BP, it was financially rewarding (56% of respondents), and patients appreciated it (64% of respondents). Despite half of the optometrists having access to BP monitors (predominantly automated devices), many of the optometrists were unsure if they were trained enough to monitor BP in such patients. There is urgent need to train optometrists on the use of BP devices, interpretation of readings, and use of additional diagnostic tests during such eye examinations.
Collapse
|
22
|
Evaluation of the Comparative Effect of Tetracaine on Central Corneal Thickness Measured by a Contact and Noncontact Pachymeter. J Ocul Pharmacol Ther 2013; 29:68-74. [DOI: 10.1089/jop.2011.0242] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
|
23
|
Comparison of the influence of nonpreserved oxybuprocaine and a preserved artificial tear (thera tears) on human corneal thickness measured by two pachymeters. J Ocul Pharmacol Ther 2013; 29:462-8. [PMID: 23331053 DOI: 10.1089/jop.2012.0215] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
PURPOSE To compare the effect of nonpreserved oxybuprocaine and preserved artificial tears on central corneal thickness (CCT) obtained by 2 pachymeters. METHODS In this prospective, placebo-controlled study, involving a random sample of 100 eyes of 50 subjects, aged 24±2.3 years, CCT readings were obtained in 2 separate sessions with the Topcon SP-3000P and ultrasound pachymetry (USP), respectively, before, 5 and 10 min after instillation of a drop each of either oxybuprocaine hydrochloride (oxybuprocaine HCl) (group 1) or carboxymethylcellulose sodium, thera tears (group 2), and placebo. RESULTS The baseline mean CCT for SP-3000P was 509±38 μm and 542±36 μm for USP. No statistical significant differences between baseline CCTs (P>0.05 for both devices) in both groups. In both group experimental eyes, neither SP-3000P nor USP-measured CCTs varied significantly from the control eyes at 5 (P>0.05) and 10 (P>0.05) mins postinstillation of drops in both sessions. In group one, the 95% confidence intervals (CIs) for the SP-3000P CCTs were similar at 5 (-16 to 17 μm) and 10 min (-16 to 17 μm), but in the USP-measured CCTs, it was wider at 10 min (-41 to 46 μm) than at 5 min (-30 to 41 μm) postinstillation. In group two, the 95% CIs at 5 and 10 mins postinstillation, respectively, ranged between -20 and 47 μm, -21 and 43 μm (SP-3000P) and -29 and 23 μm, -26 and 23 μm (USP). Within groups and between groups, variations in CCT were similar at both times intervals in all comparisons. CONCLUSION Although oxybuprocaine HCl and thera tears consistently did not affect the mean CCT obtained by both devices at both time intervals, variation in SP-3000P measured CCT was more consistent in both sessions and narrower in relation to USP-measured CCT. It may be reasonable to suggest that measurements of CCT in normal patients be taken before examinations requiring instillation of anesthetics or such measurements when obtained postinstillation of either oxybuprocaine or preserved artificial tears be interpreted with caution.
Collapse
|
24
|
Influence of central corneal thickness on measured intraocular pressure differentials: Nidek RKT-7700, Topcon CT-80 NCTs and Goldmann Tonometer. Ophthalmic Physiol Opt 2012; 32:547-55. [PMID: 23009324 DOI: 10.1111/j.1475-1313.2012.00945.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2012] [Accepted: 08/31/2012] [Indexed: 11/26/2022]
Abstract
PURPOSE We sought to compare the intraocular pressure (IOP) measured by RKT-7700 and CT-80 noncontact tonometers (NCTs) with that measured by Goldmann applanation tonometry (GAT). We also examined the influence of central corneal thickness (CCT) on the agreement between both NCTs and GAT in a sub-population of healthy, young normals. METHODS Triplicate IOP and CCT measurements were obtained twice from one randomized eye of 49 subjects (28 males and 21 females) aged 22.2 ± 1.3 (mean ± S.D.) years. Goldmann tonometry was performed subsequent to assessment with the RKT-7700 and CT-80, to negate the 'ocular massage effect', followed by ultrasound pachymetry. The results from each method were compared and assessed for repeatability and between-observer reproducibility. Analysis was performed to determine the correlation between the differences in IOP measurements and corneal thicknesses. RESULTS The mean differences (±S.D.) in sessions 1 and 2 respectively between RKT-7700 and GAT (2.6 ± 2.0 and 2.7 ± 1.4 mmHg), between CT-80 and GAT (2.8 ± 2.0 and 3.2 ± 1.3 mmHg) were statistically significant (p < 0.0001). The repeatability coefficients in sessions 1 and 2 respectively were; ±1.2 and ±1.0 mmHg (GAT), ±1.3 and ±1.6 mmHg (CT-80), ±2.3 and ±1.7 mmHg (RKT-7700) and inter-observer reproducibility was; ±1.9 (RKT-7700), ±2.3 (GAT) and ±2.6 mmHg (CT-80). Between the corneal thickness and the differences in GAT-measured and NCT-measured IOPs, there was a significant negative correlation and a trend for a larger difference in thicker corneas. CONCLUSION Neither the RKT-7700 nor the CT-80 can be used interchangeably with the Goldmann tonometer, although all three tonometers give repeatable measurements of IOP, in this sub-population. IOP differences between GAT and the NCTs significantly correlated with CCT, with the possibility of even greater differences in thicker corneas.
Collapse
|
25
|
Changes in central corneal thickness values after instillation of oxybuprocaine hydrochloride 0.4%. Cont Lens Anterior Eye 2012; 35:199-202. [PMID: 22704944 DOI: 10.1016/j.clae.2012.05.004] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2012] [Revised: 05/20/2012] [Accepted: 05/21/2012] [Indexed: 11/26/2022]
Abstract
PURPOSE To assess the variation in central corneal thickness (CCT) following the instillation of oxybuprocaine hydrochloride (0.4%), in normal subjects. METHODS This was a randomized, prospective study of CCT measurements (before and after the instillation of topical anaesthesia) obtained with the Topcon SP-3000P noncontact specular microscope, in 60 eyes of thirty subjects. The subjects' mean age was 20±1 years (mean±SD). In each subject, one eye was treated with one drop of oxybuprocaine hydrochloride (HCl) and the fellow eye with one drop of normal saline (control). The SP-3000P CCT readings were first obtained before instillation (baseline) and monitored every 30 s after instillation of each eye drop for a period of 10 min. RESULTS The mean baseline CCT for oxybuprocaine was 526±23 μm. Ten minutes after, it was 526±24 μm. In the control, the mean CCT was 526±27 μm, 10 min after it was 526±28 μm. The mean variation in CCT measurement was -0.7±3.1 (5.5 to -6.8 μm, 95% CI) for oxybuprocaine and -0.6±4.1 μm (7.5 and -8.6 μm, 95% CI) for the fellow eyes (P>0.05). There was no significant variation among the 20 CCT columns for either oxybuprocaine or the control group (P>0.05 for both). CONCLUSIONS One drop of topical oxybuprocaine 0.4% did not cause a significant change in CCT at up to 10 min following instillation. However, higher differences were observed at 2.30 min and 4.30 min after instillation.
Collapse
|
26
|
Abstract
Background The intraocular pressures and biomechanical parameters measured by the ocular response analyzer make the analyzer a useful tool for the diagnosis and management of anterior segment disease. This observational study was designed to investigate the effect of topical anesthesia on the parameters measured by the ocular response analyzer: corneal hysteresis, corneal resistance factor, Goldmann-correlated intraocular pressure (IOPg), and corneal-compensated intraocular pressure (IOPcc). Methods Two sets of measurements were made for 78 eyes of 39 subjects, approximately 1 week apart. In session 1, each eye of each subject was randomized into one of three groups: polyvinyl alcohol (0.5%), tetracaine hydrochloride (0.5%), or oxybuprocaine hydrochloride (0.4%). In session 2, eyes that were in the polyvinyl alcohol group in session 1 were assigned to the tetracaine group, those in the tetracaine group in session 1 were assigned to oxybuprocaine group, and those in the oxybuprocaine group in session 1 were assigned to the polyvinyl alcohol group. For both sessions, each subject first had his or her central corneal thickness assessed with a specular microscope, followed by measurements of intraocular pressure and corneal biomechanical parameters with the Ocular Response Analyzer. All measurements were repeated for 2 minutes and 5 minutes following the instillation of either polyvinyl alcohol, tetracaine, or oxybuprocaine. The level of statistical significance was 0.05. Results Polyvinyl alcohol, tetracaine hydrochloride, and oxybuprocaine hydrochloride had no statistically significant (P > 0.05) effect on any of the biomechanical parameters of the cornea. There was no statistically significant effect on either IOPg (P > 0.05) or IOPcc (P > 0.05) 2 minutes after the eye drops were instilled in either session. Five minutes after the eye drops were instilled, polyvinyl alcohol showed no statistically significant effect on either IOPg (P > 0.05) or IOPcc (P > 0.05) in either session. Oxybuprocaine and tetracaine caused statistically significant (P < 0.05) reductions in IOPg in session 1, but only tetracaine had a significant (P < 0.05) effect in session 2. Tetracaine also caused a statistically significant (P < 0.05) reduction in IOPcc in session 1. Conclusion The statistically significant effect of topical anesthesia on IOPg varies with the anesthetic used, and while this effect was statistically significant in this study, the small effect is probably not clinically relevant. There was no effect on any of the biomechanical parameters of the cornea.
Collapse
|
27
|
Repeatability and interobserver reproducibility of Artemis-2 high-frequency ultrasound in determination of human corneal thickness. Clin Ophthalmol 2012; 6:761-9. [PMID: 22693418 PMCID: PMC3367432 DOI: 10.2147/opth.s31690] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Background The purpose of this study was to assess the repeatability and limits of agreement of corneal thickness values measured by a high-frequency ultrasound (Artemis-2), hand-held ultrasound pachymeter (DGH-500) and a specular microscope (SP-3000P). Methods Central corneal thickness (CCT) was analyzed in this prospective randomized study that included 32 patients (18 men and 14 women) aged 21–24 years. Measurements were obtained in two sessions, one week apart, by two examiners with three devices in a randomized order. Nine measurements were taken (three with each device) on one randomly selected eye of each patient in each measurement session. The coefficient of repeatability and interobserver reproducibility for the values of each method were calculated. The limits of agreement between techniques were also evaluated. Results There were no significant differences in CCT values between sessions for each of the three devices (P > 0.05). The repeatability coefficients for the Artemis-2 (±8 μm/±9 μm) were superior to those of the SP-3000P (±9 μm/±11 μm) and DGH 500 (±12 μm/±12 μm) in session 1/session 2 respectively, while the interobserver reproducibility index (differences between session 1 and session 2) was superior for the SP-3000P (±17 μm) with respect to DHG-500 (±29 μm) and the Artemis-2 (±31 μm). In session 1 and session 2, the limits of agreement between the techniques were 35 μm to −31 μm and 34 to −20 μm, respectively, for DGH-500 versus Artemis-2, 73 μm to 3 μm and 60 μm to 9 μm for Artemis-2 versus SP-3000P, and 58 μm to 22 μm and 72 μm to 10 μm for DGH-500 versus SP-3000P comparisons. The DGH-500 and Artemis-2 gave similar values (P > 0.05) in both sessions, but both (Artemis-2 and DGH-500) values were significantly greater than that of the SP-3000P (P < 0.05) in both sessions. Conclusion Repeatability was comparably good for the three techniques. However, interobserver reproducibility was approximately twice as good with the SP-3000P compared with the other two devices. The Artemis-2 CCT values consistently agreed with the DGH-500 and less so with the SP-3000P. The Artemis-2 provided CCT values that were, on average, 38 μm and 34 μm greater than that of the SP-3000P in session 1 and session 2, respectively.
Collapse
|
28
|
The influence of lens power and center thickness on the intraocular pressure measured through soft lenses: a comparison of two noncontact tonometers. Cont Lens Anterior Eye 2012; 35:118-28. [PMID: 22322110 DOI: 10.1016/j.clae.2012.01.002] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2011] [Revised: 12/13/2011] [Accepted: 01/12/2012] [Indexed: 11/19/2022]
Abstract
PURPOSE To quantify the influence of soft contact lens power and thickness on the intraocular pressure (IOP). METHODS Thirty-nine young, healthy adult volunteers completed this study. One eye of each subject was randomly assigned either a +6D or a -6D high water content daily disposable lens. The other eye was fitted with the second lens. Triplicate measurements of IOP were taken before, during, and after contact lens wear. Each time, IOP was assessed in a randomized order with two noncontact tonometers. The lenses were swapped between eyes during a second session of measurements, one week later. RESULTS In the first session with the +6D lenses, the average IOPs (±SDs) before, with the lenses fitted, and after the lenses were removed, were: 14.3 ± 2.9 mmHg, 17.0 ± 3.3 mmHg and 13.9 ± 3.1 mmHg, respectively, for the CT80 and 13.6 ± 3.1 mmHg, 17.1 ± 4.5 mmHg and 13.3 ± 2.9 mmHg, respectively, for the PT100. The corresponding values for the first session with the -6D lenses were: 14.3 ± 3.1 mmHg, 13.1 ± 3.1 mmHg and 14.1 ± 3.3 mmHg, respectively, for the CT80 and 13.6 ± 3.2 mmHg, 13.0 ± 3.0 mmHg and 13.6 ± 3.2 mmHg, respectively, for the PT100. IOP significantly (P<0.05) increased (+ΔIOP=2.7 ± 0.4 mmHg with the CT80 in the first session) with the +6D lenses, but decreased (P<0.05) when the -6D lenses were fitted (-ΔIOP=0.6 ± 0.2 mmHg with the PT100 in the first session). The soft contact lens-induced changes were consistent between sessions but varied between tonometers. CONCLUSIONS The measurement of IOP through soft contact lenses resulted in consistent, statistically significant differences in IOP, which were not uniform across tonometers and which did not appear to be solely related to the central thickness of the soft contact lenses.
Collapse
|
29
|
Two-position measurement of intraocular pressure by PT100 noncontact tonometry in comparison with Goldmann tonometry. Clin Ophthalmol 2011; 5:1227-34. [PMID: 21966192 PMCID: PMC3180489 DOI: 10.2147/opth.s23922] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022] Open
Abstract
Background The purpose of this study was to evaluate the precision of intraocular pressure measurements obtained by PT100 noncontact tonometry in a handheld and slit lamp-mounted position in comparison with that of Goldmann applanation tonometry in healthy young adults. Methods Sixty eyes from 60 subjects (30 men and 30 women) aged 22 ± 1 (range 20–24) years participated in this study. Triplicate intraocular pressure measurement of a randomly selected eye was obtained by a noncontact tonometer in a handheld and slit lamp-mounted position in a randomized order, with the Goldmann applanation tonometer always performed last. A second measurement session was carried out after one week to assess repeatability. Results The mean ± standard deviation of intraocular pressure readings in the first and second session, respectively, with the three techniques were: handheld position, 14.52 ± 3.28 mmHg and 15.26 ± 2.11 mmHg; slit lamp-mounted position, 14.01 ± 2.80 mmHg and 15.16 ± 2.34 mmHg; and Goldmann applanation tonometer, 14.86 ± 3.26 mmHg and 15.16 ± 2.42 mmHg. There were no significant differences (P > 0.05) between the techniques in the intraocular pressure measurements returned (Goldmann applanation tonometer vs handheld and Goldmann applanation tonometer vs slit lamp-mounted). The Goldmann applanation tonometer measured intraocular pressure 0.34 mmHg higher than handheld and 0.85 mmHg higher than slit lamp-mounted in session 1, and in session 2 Goldmann applanation tonometer intraocular pressure measurement was the same as with the slit lamp-mounted method but lower than with the handheld method by 0.11 mmHg. In PT100 handheld vs slit lamp-mounted comparisons, there were no significant differences (P > 0.05) between intraocular pressure measurements returned by both techniques in sessions 1 and 2. Intrasession and intersession repeatability coefficients for Goldmann applanation tonometer intraocular pressure and slit lamp-mounted intraocular pressure were similar, and better in comparison with those for handheld intraocular pressure. Conclusion The Goldmann applanation tonometer and PT100 noncontact tonometer in both positions studied here are reliable, consistent techniques for measurement of intraocular pressure, and can be used interchangeably for obtaining intraocular pressure values in young normal subjects. Repositioning of the PT100 tonometer from hand-held to slit lamp-mounted improved its precision and reduced variation with respect to the Goldmann applanation tonometer.
Collapse
|
30
|
Comparison of the precision of the Topcon SP-3000P specular microscope and an ultrasound pachymeter. Clin Ophthalmol 2011; 5:871-6. [PMID: 21760714 PMCID: PMC3133003 DOI: 10.2147/opth.s21247] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2011] [Indexed: 11/23/2022] Open
Abstract
AIM To compare the precision of the Topcon SP-3000P noncontact specular microscope (NCSM) and the DGH 500 ultrasound pachymeter (USP). METHODS Triplicate measurements of central corneal thickness (CCT) for 100 eyes were taken with an NCSM and a USP in 2 visits separated by 1 week. Repeatability was assessed by computing the differences between all 3 readings from each subject. Coefficients of repeatability and reproducibility were computed. RESULTS MEAN CCT AS MEASURED BY EACH INSTRUMENT WERE: 518.53 ± 34.96 μm (range 417.33-592.67) and 516.94 ± 33.60 μm (range 431.67-582.67) for sessions 1 and 2 respectively, with the NCSM; 546.69 ± 36.62 μm (range 457.33-617.00) and 549.78 ± 35.26 μm (range 454.00-618.67) for sessions 1 and 2 respectively, with the USP. The ultrasound CCT measurements were consistently higher than those obtained with the NCSM in both sessions 28.17 ± 19.20 μm (mean ± SD, session 1) and 32.81 ± 14.04 (mean ± SD, session 2). The repeatability coefficient for the NCSM was better in both sessions than those for USP (±10 μm vs ± 12 μm in session 1 and ±8 μm vs ±10 μm in session 2). The reproducibility coefficient with the NCSM was half that with the USP (±21 μm vs ±41 μm). CONCLUSION The SP-3000P NCSM is a more precise and reproducible instrument for measurement of CCT than the USP, but both instruments are reliable, useful instruments for measuring CCT.
Collapse
|
31
|
Abstract
PURPOSE Comparison of the magnitude and repeatability of the intraocular pressure (IOP) measured with the Ocular Response Analyzer (ORA) to that measured with the Goldmann tonometer. METHODS Two sets of IOP measurements were made, for 89 eyes of eighty-nine subjects, approximately 1-week apart. Goldmann tonometry was performed subsequent to non-contact tonometry, in which the order of measurement was randomized between the ORA and the Topcon CT80 non-contact tonometer (CT80). Each method was assessed twice for intrasession repeatability. The limits of agreement between each non-contact pressure and that measured with the Goldmann tonometer were assessed once per session. The level of statistical significance was 0.05. RESULTS The mean differences between the ORA-corneal compensated, Goldmann-correlated, and CT80-IOP (ORA-IOPcc; ORA-IOPg and CT80-IOP) versus the Goldmann IOP were -0.3 +/- 2.7 mmHg (mean +/- SD), -0.3 +/- 2.2 mmHg and -0.3 +/- 2.1 mmHg, respectively for session 1 and 0.3 +/- 3.0 mmHg, 0.2 +/- 2.2 mmHg, and -0.5 +/- 2.2 mmHg, respectively, for session 2. The repeatability coefficients were +/- 5.3 mmHg, +/- 4.2 mmHg, +/- 2.5 mmHg, and +/- 1.9 mmHg, respectively for ORA-IOPcc, ORA-IOPg, CT80-IOP, and Goldmann IOP in session 1 and +/- 3.8 mmHg, +/- 3.6 mmHg, +/- 1.6 mmHg, and +/- 1.9 mmHg, respectively for session 2. CONCLUSION The repeatability indices for the ORA were poorer than those with the Goldmann tonometer and the CT80 in both sessions. However, the average IOP measured with the ORA did not vary significantly from those measured with the other two tonometers in either session. The ORA provides valid, repeatable measures of IOP.
Collapse
|
32
|
Abstract
BACKGROUND In studies aimed at assessing the accuracy and repeatability of non-contact tonometers, the order in which these tonometers and the Goldmann tonometer are used is usually randomised despite studies in the literature that demonstrate an ocular massage effect that occurs post-applanation but not after non-contact tonometry. The purpose of this study was to investigate the effect of repeated corneal applanation on subsequent assessments of IOP. METHODS Data were obtained from 65 left eyes of 65 young, oculovisual normals. Three sets of IOP measurements were obtained, one set with the Goldmann applanation tonometer and two with the Topcon CT80 non-contact tonometer (one set each before and after applanation with the Goldmann tonometer), in each one of two separate measurement sessions, one week apart. RESULTS The average (and SD) IOP measured with the Goldmann tonometer in the first session (14.8+/-2.9 mmHg) did not vary significantly from the IOP measured with the non-contact tonometer (pre-applanation) in both sessions or with the average Goldmann IOP in the second session. The bias (mean difference +/- SD) between methods was 0.3+/-1.4 mmHg and 0.4+/-1.4 mmHg, respectively, for the first and second sessions, with the CT80 (pre-applanation) recording the higher IOP in both sessions. The within-session repeatability coefficients were +/-2.3 mmHg, +/-2.6 mmHg, +/-2.1 mmHg and +/-2.0 mmHg for the CT80 (pre-applanation) in the first and second sessions, and the Goldmann tonometer in the first and second sessions, respectively. Test-retest repeatability coefficients were +/-2.8 mmHg and +/-2.5 mmHg for the CT80 (pre-applanation) and the Goldmann tonometer respectively. Post-applanation with the Goldmann tonometer, there was a statistically significant (p<0.05) reduction (1.5+/-1.2 mmHg in session 1) in the IOP measured with the non-contact tonometer in both sessions. CONCLUSION These results suggest that repeated corneal applanation leads to a statistically significant reduction in IOP on subsequent measurements.
Collapse
|
33
|
Clinical investigation of the effect of topical anesthesia on intraocular pressure. Clin Ophthalmol 2007; 1:305-9. [PMID: 19668485 PMCID: PMC2701119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
BACKGROUND/AIMS Contact tonometry is generally considered more accurate than non-contact tonometry in the assessment of intraocular pressure (IOP). This study was designed to investigate the effect of ocular anesthesia, a pre-requisite for contact tonometry, on the IOP in a sample of visually normal subjects. METHOD In a random sample of 120 young visually normal subjects (divided equally among three groups), the Topcon CT80 non-contact tonometer was used to measure IOP before, at the second minute and at the fifth minute following instillation of one drop of one of three eyedrops - carboxymethylcellulose sodium 0.5% (control), oxybuprocaine hydrochloride 0.4% and proparacaine hydrochloride 0.5%. RESULTS The IOP measured before instilling the ophthalmic drops did not vary significantly among the three groups of subjects (p > 0.05). In the control group, the average IOP of 15.1 +/- 2.6 mmHg did not vary significantly (p > 0.05) 2 minutes and 5 minutes following instillation of one drop of Carboxymethylcellulose sodium. There were statistically significant reductions of IOP 2 minutes (p < 0.01) and 5 minutes (p < 0.001) after the instillation of one drop of oxybuprocaine hydrochloride. One drop of proparacaine hydrochloride caused significant reductions in the average IOP after 2 minutes (p < 0.001) and after 5 minutes (p < 0.001). CONCLUSIONS One drop of topical proparacaine or oxybuprocaine may cause a small but a statistically significant reduction in IOP which could lead to lower IOP readings.
Collapse
|
34
|
Abstract
BACKGROUND The reliability of non-contact tonometers has been reported extensively in the literature. This study was designed to assess reliability of the new Topcon CT80 non-contact tonometer in normotensive subjects, using the Goldmann tonometer as the standard. METHODS The accuracy of the Topcon CT 80 non-contact tonometer was assessed by comparing its IOP assessments with those of the Goldmann applanation tonometer, on 60 right eyes of young healthy subjects with normal intraocular pressures. Each subject's intraocular pressure was assessed with each technique on two separate occasions, one week apart. The reliability of each technique was determined by the assessment of its inter-session repeatability using the Bland-Altman method. The 95 per cent limits of agreement for the two methods were also determined. RESULTS No statistically significant difference was found between the average intraocular pressures measured with the two techniques (p > 0.05). The inter-session repeatability indices for the two techniques did not differ significantly (p > 0.05). The mean difference in intraocular measurements between the two techniques was 0.2 +/- 1.5 mmHg (mean +/- SD) and the 95 per cent limits of agreement were -3.14 and +2.74 mmHg, with the non-contact tonometer returning higher readings than the Goldmann tonometer. CONCLUSION In this sample of normotensive subjects, the Topcon CT80 non-contact tonometer proved to be accurate and as reliable as the Goldmann tonometer in the assessment of intraocular pressure. Thus, it can be used as an objective clinical method for the assessment of normal intraocular pressure.
Collapse
|
35
|
Smith-method assessment of anterior chamber depth for screening for narrow anterior chamber angles. Indian J Ophthalmol 2006; 54:165-8. [PMID: 16921212 DOI: 10.4103/0301-4738.27066] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
PURPOSE To compare the axial anterior chamber depth (ACD) using the Smith method, in patients under treatment for primary open-angle glaucoma (POAG) and primary angle-closure glaucoma (PACG), with an age-matched control group. MATERIALS AND METHODS Triplicate just-touching-slit-length (JTSL) measurements of the axial anterior chamber depth were determined in 198 eyes of 99 patients (39 control; 36 POAG; and 24 PACG) recruited from King Saud University clinics, Riyadh, Saudi Arabia. Goldmann tonometry and gonioscopy were carried out as a part of the patient's routine examination. Subjects with a history of intraocular surgery for glaucoma or any other anterior segment disease were excluded form the study. The average ACD estimate by the JTSL method were compared among the various groups. RESULTS The average JTSL estimates were: Control group 2.33+/-0.68 mm (axial ACD estimate = JTSL estimate x 1.4); POAG group 1.98+/-0.97 mm; PACG group 0.65+/-0.41 mm. There was no significant reduction (P = 0.068) of the JTSL estimate in the POAG group, compared to the control group. There was a statistically significant (P < 0.001) reduction of the JTSL estimate in the PACG group, compared to both the control and POAG groups. CONCLUSION The Smith-method JTSL technique may be used for non-invasive rapid screening, to help identify patients at risk of developing angle-closure, during routine examination of patients in the ophthalmology clinic.
Collapse
|
36
|
Abstract
PURPOSE To determine the limits of agreement between central corneal thickness (CCT) measurements made with the slit lamp-attached optical pachymeter and the SP2000P noncontact specular microscope. METHODS Triplicate readings for CCT were obtained for each of 130 (right) eyes of 130 patients, using the slit lamp-attached optical pachymeter and then the SP2000P noncontact specular microscope. The average CCT measured by each method was compared. Subsequently, the mean difference between both sets of measurements was assessed, and the 95% confidence interval (limits of agreement) between both techniques was determined. RESULTS The mean +/- SD CCT measured by the optical pachymeter was 543 +/- 34 microm and 532 +/- 34 microm for the specular microscope. We found a statistically significant (P < 0.001) mean bias of 10 mum between CCT values measured with both types of equipment, with the optical pachymeter returning the higher values. The coefficient of variation was 6.3% for the optical pachymeter and 6.4% for the specular microscope. CONCLUSIONS The right eye CCT measurements made by the optical pachymeter are, on average, 10 mum thicker than those made with the SP2000P specular microscope, which suggests that both pieces of equipment cannot be used interchangeably to monitor CCT changes in patients. Excluding left eye measurements, the reliability of the optical pachymeter is identical to that of the noncontact specular microscope.
Collapse
|
37
|
Repeatability of central corneal thickness measurements measured with the Topcon SP2000P specular microscope. Graefes Arch Clin Exp Ophthalmol 2005; 243:798-802. [PMID: 16133035 DOI: 10.1007/s00417-005-1149-2] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2004] [Revised: 01/07/2005] [Accepted: 01/14/2005] [Indexed: 10/25/2022] Open
Abstract
BACKGROUND The non-contact specular microscope has become the method of choice for a quick, accurate and non-invasive assessment of central corneal thickness (CCT), which is an important variable to monitor before and after refractive surgery. The consistency of the results produced by such widely used methods/equipment must be assessed to determine their reliability. The purpose of this study was to assess within- and between-observer repeatability of, and to determine if a systematic bias exists in the measurements made by, the Topcon SP2000P specular microscope. METHODS The CCT of the right eyes of 70 adult subjects, divided equally between men and women, was assessed on two separate occasions (4-7 days apart) by each of two examiners using the low-intensity auto mode of the SP2000P specular microscope. RESULTS The average CCT values for men and women, measured by one observer, were 0.52+/-0.03 mm (mean +/- SD) and 0.52+/-0.04 mm, respectively. The average for the entire sample was 0.52+/-0.04 mm. Within- and between-observer repeatability were assessed by plotting the mean difference (for each subject) between two readings made by the same observer or one each by both observers against the combined average CCT reading of both sessions; the mean difference between two sets of observations was not significantly different from zero (P<0.05). For the first observer, the 95% limits of repeatability were between -0.015 and 0.017 mm. For the second observer, the 95% limits of repeatability were between -0.018 and 0.018 mm. For the between-observer repeatability, the 95% limits of agreement were between -0.016 and 0.016 mm. For both within- and between-observer repeatability, we found no systematic bias of the mean difference with the average CCT reading. CONCLUSION The within- and between-observer limits of agreement we found were similar to those previously reported for the Topcon SP2000P specular microscope; the range of the 95% limits of repeatability were within +/-1 SD of the average CCT reading for both sessions. We suggest that a technique be considered reliable if: (1) the mean difference between two measurements does not vary significantly from zero, (2) there is no systematic bias of the mean difference with the magnitude of the measured quantity and (3) the error inherent in a measurement technique is within +/-1 SD of the average measurement of the two sessions.
Collapse
|
38
|
Intra-observer repeatability and inter-observer agreement of the Smith method of measuring the anterior chamber depth. Ophthalmic Physiol Opt 2000; 20:153-9. [PMID: 10829139] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023]
Abstract
The Smith (1979) method provides a means of estimating the anterior chamber depth without additional attachments to the slit lamp [Smith, R. J. H. (1979). A new method of estimating the depth of the anterior chamber. Br. J. Ophthalmol. 63, 215-220]. In this study, the 95% intra-observer limits of repeatability and the 95% inter-observer limits of agreement of this method have been determined. The intra-observer limits of repeatability were determined by plotting the difference vs the mean of the estimated anterior chamber depth obtained in two different sessions by each of two examiners, while the inter-observer limits of agreement are represented by a plot of the difference vs the mean estimated anterior chamber depth between the two examiners. For one examiner, the 95% intra-observer limits of repeatability was -0.36 to 0.58 mm, while for the other examiner the 95% intra-observer limits of repeatability was -0.25 to 0.37 mm. The 95% inter-observer limits of agreement were -0.31 to 0.23 mm and -0.41 to 0.25 mm for the first and second sessions respectively. The intra-observer limits of repeatability are comparable with those reported for A-scan ultrasonographic measures of the anterior chamber depth. These results imply that the Smith method can be used with a high degree of repeatability and agreement to clinically monitor longitudinal changes in anterior chamber depth.
Collapse
|
39
|
Two pathways for electrogenic bicarbonate ion movement across the rabbit corneal endothelium. BIOCHIMICA ET BIOPHYSICA ACTA 1996; 1279:104-10. [PMID: 8624354 DOI: 10.1016/0005-2736(95)00232-4] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
Amiloride (0.5 mM) inhibited the rate of entry of Na+ into corneal endothelial cells by more than half ((0.76 +/- 0.10) to (0.21 +/- 0.10) microEq cm(-2)h(-1)). The same concentration of amiloride caused only minimal disturbance to corneal hydration control by the endothelium (range 0-12%). Amiloride (0.5 mM) and acetazolamide (1 mM) reversibly inhibited trans-endothelial short circuit current by about a half. Their combined effect was not additive. Acetazolamide (1 mM) reduced net HCO3- flux across the short-circuited endothelium by about the same amount ((0.50 +/- 0.11) microEq cm(-2)h(-1)) that amiloride (0.5 mM) reduced Na+ entry into the cells ((0.55 +/- 0.14) microEq cm(-2)h(-1)). Low concentrations of amiloride (10 microM) had little effect on the transport characteristics of the endothelium, indicating that Na+ entry into the endothelial cells under physiological conditions is not primarily through Na+ channels. The data are consistent with an Na+/H+ exchanger acting in tandem with carbonic anhydrase through a pathway which could have a regulatory role on endothelial transport via its effect on Na+ re-entry. Residual trans-endothelial HCO3- transport, apparently unaffected by amiloride or acetazolamide inhibition, is calculated to be of sufficient magnitude to maintain corneal hydration.
Collapse
|