1
|
Diagnostic Performance of Whole-Body Ultra-Low-Dose CT for Detection of Mechanical Ventriculoperitoneal Shunt Complications: A Retrospective Analysis. AJNR Am J Neuroradiol 2022; 43:1597-1602. [PMID: 36229165 PMCID: PMC9731254 DOI: 10.3174/ajnr.a7672] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2022] [Accepted: 09/07/2022] [Indexed: 02/01/2023]
Abstract
BACKGROUND AND PURPOSE Radiographic shunt series are still the imaging technique of choice for radiologic evaluation of VP-shunt complications. Radiographic shunt series are associated with high radiation exposure and have a low diagnostic performance. Our aim was to investigate the diagnostic performance of whole-body ultra-low-dose CT for detecting mechanical ventriculoperitoneal shunt complications. MATERIALS AND METHODS This retrospective study included 186 patients (mean age, 54.8 years) who underwent whole-body ultra-low-dose CT (100 kV[peak]; reference, 10 mAs). Two radiologists reviewed the images for the presence of ventriculoperitoneal shunt complications, image quality, and diagnostic confidence. On a 5-point Likert scale, readers scored image quality and diagnostic confidence (1 = very low, 5 = very high). Sensitivity, specificity, positive predictive value, and negative predictive value were calculated. Radiation dose estimation of whole-body ultra-low-dose CT was calculated and compared with the radiation dose of a radiographic shunt series. RESULTS 34 patients positive for VP-shunt complications were correctly identified on whole-body ultra-low-dose CT by both readers. No false-positive or -negative cases were recorded by any of the readers, yielding a sensitivity of 100% (95% CI, 87.3%-100%), a specificity of 100% (95% CI, 96.9%-100%), and perfect agreement (κ = 1). Positive and negative predictive values were high at 100%. Shunt-specific image quality and diagnostic confidence were very high (median score, 5; range, 5-5). Interobserver agreement was substantial for image quality (κ = 0.73) and diagnostic confidence (κ = 0.78). The mean radiation dose of whole-body ultra-low-dose CT was significantly lower than the radiation dose of a conventional radiographic shunt series (0.67 [SD, 0.4] mSv versus 1.57 [SD, 0.6] mSv; 95% CI, 0.79-1.0 mSv; P < .001). CONCLUSIONS Whole-body ultra-low-dose CT allows detection of ventriculoperitoneal shunt complications with excellent diagnostic accuracy and diagnostic confidence. With concomitant radiation dose reduction on contemporary CT scanners, whole-body ultra-low-dose CT should be considered an alternative to the radiographic shunt series.
Collapse
|
2
|
Abstract
The indications for orbital tumor surgery are an incisional biopsy to confirm the diagnosis or in malignant operable tumors a complete excision or a debulking to avoid complications in large invasively infiltrating tumors. In the case of benign tumors, the indications for surgery depend mostly on the clinical symptoms and cosmetic esthetic disfigurement. In the present article the preoperative examinations as well as surgical access approaches to different orbital regions, endoscopic procedures and methods of intraoperative navigation are presented. Magnetic resonance imaging is the instrument of choice, whereby in many cases computed tomography (CT) adds further information. Depending on the indications, diffusion-weighted sequences, CT angiography and digital subtraction angiography (DSA, catheter angiography) are added to the preoperative diagnostics. For space-occupying lesions located anterior to the bulbar equator, an anterior orbitotomy can be performed transconjunctivally or transpalpebrally. A lateral orbitotomy is used to reach lateral, laterocranial, and lateroinferior orbital segments, whereas transcranial approaches are suitable for processes located far posterior and for those with retro-orbital intracranial extension as well as for processes in the optic foramen/superior orbital fissure. The indications for an endonasal access approach are processes medial to the bulb or optic nerve and up to the orbital apex. A transantral access can be chosen for caudal, mediolateral, and medioinferior space-occupying lesions. Modern orbital surgery is complemented by endoscopic procedures and intraoperative navigation. Orbital tumors belong to the interdisciplinary relevant diseases. Therefore, an optimal management takes place at specialized multidisciplinary centers.
Collapse
|
3
|
|
4
|
Intraindividual comparison of selective intraarterial
versus systemic intravenous 68Ga-DOTATATE PET/CT in patients with
inoperable meningioma. Nuklearmedizin 2019; 58:23-27. [DOI: 10.1055/a-0802-5039] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Abstract
Aim Here we describe the results of superselective intraarterial
application of diagnostic Ga-68-DOTA0,Tyr3-octreotate (Ga-68-DOTATATE) in a
series of patients with inoperable WHO grade II meningiomas which were no longer
amenable to radiotherapy.
Methods Four patients with inoperable WHO grade II meningioma underwent
systemic venous infusion of Ga-68-DOTATATE followed by PET/CT. Ga-68-DOTATATE
application was repeated intraarterially via transfemoral catheterization of
vessels supplying the meningioma and another PET/CT was performed.
Results Selective arterial infusion of Ga-68-DOTATATE increased the median
value for the maximum standardized uptake value (SUV) by 2.6-fold (median
venous: 7.1, median arterial: 21.6; range 2.0–5.0) and the median value for mean
SUV by 2.7-fold (median venous: 4.3, median arterial: 11.2; range 1.6–5.6)
compared to systemic intravenous infusion. Arterial application was well
tolerated by all patients without complications. When compared to liver uptake,
intravenous tracer uptake was insufficient for PRRT, whereas tracer uptake after
superselective intraarterial tracer injection was sufficient to allow for
peptide receptor radionuclide therapy (PRRT) in all patients.
Conclusion Insufficient tracer uptake in meningiomas after intravenous
application of Ga-68-DOTATATE may be safely increased by a factor of 2–5 using
transfemoral selective intraarterial tracer application.
Collapse
|
5
|
Development of a Polymer-Based Biodegradable Neurovascular Stent Prototype: A Preliminary In Vitro and In Vivo Study. Macromol Biosci 2018; 18:e1700292. [PMID: 29855168 DOI: 10.1002/mabi.201700292] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2017] [Revised: 01/10/2018] [Indexed: 11/10/2022]
Abstract
Biodegradable stents are not established in neurovascular interventions. In this study, mechanical, radiological, and histological characteristics of a stent prototype developed for neurovascular use are presented. The elasticity and brittleness of PLA 96/4, PLDL 70/30, PCL, and PLGA 85/15 and 10/90 polymers in in vitro experiments are first analyzed. After excluding the inapt polymers, degradability and mechanical characteristics of 78 PLGA 85/15 and PLGA 10/90 stent prototypes are analyzed. After excluding PLGA 10/90 stents because of rapid loss of mass PLGA 85/15 stents in porcine in vivo experiments are analyzed. Angiographic occlusion rates 7 d, 1 month, 3 months, and 6 months after stent implantation are assessed. Histological outcome measures are the presence of signs of inflammation, endothelialization, and the homogeneity of degradation after six months. One case of stent occlusion occurs within the first 7 d. There is a prominent foreign-body reaction with considerable mononuclear and minor granulocytic inflammation combined with incomplete fragmental degradation of the struts. It is possible to produce a stent prototype with dimensions that fit the typical size of carotid arteries. Major improvements concerning thrombogenicity, degradation, and inflammatory response are required to produce biodegradable stents that are suitable for neurovascular interventions.
Collapse
|
6
|
Influence of carotid tortuosity on internal carotid artery access time in the treatment of acute ischemic stroke. Interv Neuroradiol 2017; 23:583-588. [PMID: 28944705 DOI: 10.1177/1591019917729364] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
Purpose Carotid artery anatomy is thought to influence internal carotid artery access time (ICA-AT) in patients requiring mechanical thrombectomy for acute ischemic stroke. This study investigates the association between ICA-AT and carotid anatomy. Material and methods Computed tomography angiography (CTA) data of 76 consecutive patients presenting with acute ischemic stroke requiring mechanical thrombectomy for middle cerebral artery or carotid T occlusion were evaluated. The supraaortic extracranial vasculature was analyzed regarding take-off angles and curvature of the affected side. Digital subtraction angiography data were primarily analyzed regarding ICA-AT and secondarily regarding recanalization time and radiographic result. Results ICA-AT was significantly influenced by vessel tortuosity. Take-off angle of the left common carotid artery ( p = 0.001) and the brachiocephalic trunk ( p = 0.002) as well as the tortuosity of the common carotid artery ( p = 0.002) had highest impact on ICA-AT. For recanalization time, however, we found only the take-off angle of the left common carotid artery to be of significance ( p = 0.020). There was a tendency for ICA-AT to correlate with successful (mTICI ≥ 2 b) revascularization (average time of successful results was 24.3 minutes, of unsuccessful was 35.6 minutes; p = 0.065). Every evaluated segment with less carotid tortuosity showed a carotid AT below 25 minutes. Conclusion Supraaortic vessel tortuosity significantly influences ICA-AT in mechanical thrombectomy for an acute large vessel. There furthermore was a trend for lower successful recanalization rates with increasing ICA-AT.
Collapse
|
7
|
Optimizing endovascular stroke treatment: removing the microcatheter before clot retrieval with stent-retrievers increases aspiration flow. J Neurointerv Surg 2016; 9:459-462. [PMID: 27084962 DOI: 10.1136/neurintsurg-2016-012319] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2016] [Revised: 03/23/2016] [Accepted: 03/25/2016] [Indexed: 11/03/2022]
Abstract
BackgroundFlow control during endovascular stroke treatment with stent-retrievers is crucial for successful revascularization. The standard technique recommended by stent-retriever manufacturers implies obstruction of the respective access catheter by the microcatheter, through which the stent-retriever is delivered. This, in turn, results in reduced aspiration during thrombectomy. In order to maximize aspiration, we fully retract the microcatheter out of the access catheter before thrombectomy—an approach we term the ‘bare wire thrombectomy’ (BWT) technique. We verified the improved throughput with systematic in vitro studies and assessed the clinical effectiveness and safety of this method.MethodsWe compared aspiration flow of water through various access catheters (5–8 F) with a Rebar microcatheter (0.18 inch and 0.27 inch) and a Trevo stent-retriever using the standard technique and the BWT technique in vitro. We also retrospectively analyzed 302 retrieval maneuvers in 117 patients who received endovascular treatment with a stent-retriever between February 2010 and April 2015.ResultsIn the in vitro experiment, removal of the microcatheter in all tested settings resulted in significantly increased aspiration flow through the access catheter (p<0.001). This effect was particularly pronounced in access catheters with a diameter of ≤7 F. In the clinical study, the revascularization rate (Thrombolysis In Cerebral Infarction ≥2b) was 91%. There were no complications associated with the BWT technique in 302 retrieval maneuvers.ConclusionsThe BWT technique results in improved aspiration flow rates compared with the standard deployment technique. Our clinical data show that the BWT technique is effective and safe.
Collapse
|
8
|
Weekend effect in endovascular stroke treatment: do treatment decisions, procedural times, and outcome depend on time of admission? J Neurointerv Surg 2016; 9:336-339. [DOI: 10.1136/neurintsurg-2015-012220] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2015] [Revised: 02/24/2016] [Accepted: 02/26/2016] [Indexed: 11/04/2022]
Abstract
BackgroundEpidemiologic studies identified a ‘weekend effect’ or ‘out-of-hours effect’, which implies that procedural and clinical outcomes of patients with stroke, who are admitted out-of-hours, are less favorable than for patients admitted during working-hours.ObjectiveTo determine (1) whether our procedural times and clinical outcome were affected by an out-of-hours effect and (2) whether the decision in favor of, or against, endovascular stroke treatment (EST) depends on the time of admission.MethodsBetween February 2010 and January 2015, 6412 consecutive patients presenting with symptoms of acute ischemic stroke were evaluated for EST eligibility according to established local protocols and generally accepted consensus criteria, and dichotomized into working-hours and out-of-hours cohorts according to admission times. Within both groups, patients given EST were identified and the rate of treatment decision, procedural times, and clinical outcome were compared and analyzed.ResultsClinical and radiological features of patients admitted in working-hours and out-of-hours did not differ significantly. Procedural times and clinical outcome were not affected by an out-of-hours effect (p≥0.054). 221/240 (92.1%) out-of-hours patients and 154/166 (92.8%) working-hours patients who were eligible for EST were transferred to the angiography suite for EST (p=0.798). The rationale not to treat patients who were eligible for EST did not differ between working-hours and out-of-hours admission (p=0.756).ConclusionsIt is possible to produce competitive procedural times regardless of the time of admission and to prevent a treatment decision bias when standard operating procedures are applied consistently.
Collapse
|
9
|
Active push deployment technique improves stent/vessel-wall interaction in endovascular treatment of acute stroke with stent retrievers. J Neurointerv Surg 2016; 9:253-256. [PMID: 26975839 DOI: 10.1136/neurintsurg-2016-012322] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2016] [Revised: 02/16/2016] [Accepted: 02/17/2016] [Indexed: 11/04/2022]
Abstract
BackgroundThe optimal interaction between stent struts and thrombus is crucial for successful revascularization in endovascular stroke therapy with stent retrievers. Deploying the stent retriever by actively pushing it into the thrombus increases the radial force with which the stent struts expand into the thrombus.ObjectiveTo examine the active push deployment (APD) technique in an in vitro model and present our clinical experience with this technique.MethodsIn an in vitro experiment we investigated the configuration of a Solitaire and a Trevo ProVue device (both 4×20 mm), depending on whether the devices were deployed using the APD technique or simple unsheathing. We retrospectively assessed the effectiveness and safety of this technique by analyzing 130 patients with large vessel occlusions (carotid T or M1 segment of the middle cerebral artery), who received endovascular treatment with a Trevo device (4×20 mm) that was deployed using the APD technique.ResultsIn vitro experiment: the APD technique improved apposition of the devices to the vessel wall. There was widening of 30% (Trevo) and 19% (Solitaire) at the cost of a shortening of 5% and 4%, respectively, when the devices were deployed in a carotid T model. Clinical study: the revascularization rate (Thrombolysis in Cerebral Infarction ≥2b) with the Trevo device was 90%. There were no retriever-associated dissections or perforations in 278 retrieval maneuvers.ConclusionsThe APD technique improves apposition of the tested devices to the vessel wall. The widening effect comes at the cost of minimal shortening of the devices. Our clinical experience shows that using the APD technique to deploy the Trevo device is effective and safe.
Collapse
|
10
|
Endovascular retrieval of a dislocated coil in the peroneal artery with a stent retriever. BJR Case Rep 2016; 2:20150278. [PMID: 30364396 PMCID: PMC6195927 DOI: 10.1259/bjrcr.20150278] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2015] [Revised: 10/07/2015] [Accepted: 10/18/2015] [Indexed: 11/05/2022] Open
Abstract
We present a patient who underwent successful removal of a fully detached platinum coil from the peroneal artery using a Solitaire™ stent retriever (Covidien, Irvine, CA) that is usually used in endovascular stroke treatment.
Collapse
|
11
|
Low-Dose Volume-Perfusion CT of the Brain: Effects of Radiation Dose Reduction on Performance of Perfusion CT Algorithms. Clin Neuroradiol 2015; 27:311-318. [PMID: 26669592 DOI: 10.1007/s00062-015-0489-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2015] [Accepted: 11/30/2015] [Indexed: 10/22/2022]
Abstract
PURPOSE We aimed to compare different computed tomography (CT) perfusion post-processing algorithms regarding image quality of perfusion maps from low-dose volume perfusion CT (VPCT) and their diagnostic performance regarding the detection of ischemic brain lesions. METHODS AND MATERIALS We included VPCT data of 21 patients with acute stroke (onset < 6h), which were acquired at 80 kV and 180 mAs. Low-dose VPCT datasets with 72 mAs (40 % of original dose) were generated using realistic low-dose simulation. Perfusion maps (cerebral blood volume (CBV); cerebral blood flow (CBF) from original and low-dose datasets were generated using two different commercially available post-processing methods: deconvolution-based method (DC) and maximum slope algorithm (MS). The resulting DC and MS perfusion maps were compared regarding perfusion values, signal-to-noise ratio (SNR) as well as image quality and diagnostic accuracy as rated by two blinded neuroradiologists. RESULTS Quantitative perfusion parameters highly correlated for both algorithms and both dose levels (r ≥ 0.613, p < 0.001). Regarding SNR levels and image quality of the CBV maps, no significant differences between DC and MS were found (p ≥ 0.683). Low-dose MS CBF maps yielded significantly higher SNR levels (p < 0.001) and quality scores (p = 0.014) than those of DC. Low-dose CBF and CBV maps from both DC and MS yielded high sensitivity and specificity for the detection of ischemic lesions (sensitivity ≥ 0.82, specificity ≥ 0.90). CONCLUSION Our results indicate that both methods produce diagnostically sufficient perfusion maps from simulated low-dose VPCT. However, MS produced CBF maps with significantly higher image quality and SNR than DC, indicating that MS might be more suitable for low-dose VPCT imaging.
Collapse
|
12
|
Feasibility of combined surgical and endovascular carotid access for interventional treatment of ischemic stroke. J Neurointerv Surg 2015; 8:571-5. [PMID: 26078358 DOI: 10.1136/neurintsurg-2015-011719] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2015] [Accepted: 04/15/2015] [Indexed: 11/04/2022]
Abstract
BACKGROUND Rapid recanalization of occluded vessels is crucial for good clinical outcome in acute ischemic stroke. Endovascular treatment is usually performed via a transfemoral approach, but catheterization of the carotid arteries can be problematic in cases of difficult anatomy or vascular pathologies in some cases. OBJECTIVE To describe our experience with a technique involving surgical access to the carotid artery and consecutive transcarotid endovascular thrombectomy in patients with acute stroke. METHODS In a retrospective review of a prospectively maintained registry we identified 6 patients who underwent acute endovascular thrombectomy via a surgical access to the carotid artery. RESULTS Admission National Institute of Health Stroke Scale (NIHSS) ranged from 7 to 23. Intracranial recanalization (thrombolysis in cerebral infarction, TICI≥2b) was achieved in all patients (100%). Recanalization was achieved within 19±5 min after establishing carotid access. One patient developed a small neck hematoma, which was surgically removed without complications. No complications related to endovascular therapy were seen. At 3 months' follow-up, five patients had survived. Three patients (50%) had regained excellent neurological function (modified Rankin Scale, mRS 0-1). CONCLUSIONS Surgical carotid access for endovascular stroke treatment is feasible, with considerable advantages, in patients with expected problematic access or for whom transfemoral endovascular carotid access has failed.
Collapse
|
13
|
Postoperative Befunde im Spinalkanal. ROFO-FORTSCHR RONTG 2014. [DOI: 10.1055/s-0034-1373357] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
14
|
Evaluation eines Algorithmus für die Metallartefaktreduktion zerebraler und zervikaler Flachbilddetektor-CT- und CTA-Datensätze. ROFO-FORTSCHR RONTG 2014. [DOI: 10.1055/s-0034-1373335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
15
|
Darstellung der Zona incerta im 7,0 Tesla MRT: eine Pilotstudie. ROFO-FORTSCHR RONTG 2013. [DOI: 10.1055/s-0033-1346515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
16
|
Anatomie der Arterien. ROFO-FORTSCHR RONTG 2013. [DOI: 10.1055/s-0033-1345972] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
17
|
In vivo X-ray digital subtraction and CT angiography of the murine cerebrovasculature using an intra-arterial route of contrast injection. AJNR Am J Neuroradiol 2012; 33:1702-9. [PMID: 22576899 DOI: 10.3174/ajnr.a3071] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
BACKGROUND AND PURPOSE Investigation of the anatomy, patency, and blood flow of arterial and venous vessels in small animal models of cerebral ischemia, venous thrombosis, or vasospasm is of major interest. However, due to their small caliber, in vivo examination of these vessels is technically challenging. Using micro-CT, we compared the feasibility of in vivo DSA and CTA of the murine cerebrovasculature using an intra-arterial route of contrast administration. MATERIALS AND METHODS The ECA was catheterized in 5 C57BL/6J mice. During intra-arterial injection of an iodized contrast agent (30 μL/1 sec), DSA of the intra- and extracranial vessels was performed in mice breathing room air and repeated in hypoxic/hypercapnic mice. Micro-CTA was performed within 20 seconds of intra-arterial contrast injection (220 μL/20 sec). Image quality of both methods was compared. Radiation dose measurements were performed with thermoluminescence dosimeters. RESULTS Both methods provided high-resolution images of the murine cerebrovasculature, with the smallest identifiable vessel calibers of ≤ 50 μm. Due to its high temporal resolution of 30 fps, DSA allowed identification of anastomoses between the ICA and ECA by detection of retrograde flow within the superficial temporal artery. Micro-CTA during intra-arterial contrast injection resulted in a reduced injection volume and a higher contrast-to-noise ratio (19.0 ± 1.0) compared with DSA (10.0 ± 1.8) or micro-CTA when using an intravenous injection route (1.3 ± 0.4). CONCLUSIONS DSA of the murine cerebrovasculature is feasible using micro-CT and allows precise and repeated measurements of the vessel caliber, and changes of the vessel caliber, while providing relevant information on blood flow in vivo.
Collapse
|
18
|
Intraspinale Tumoren. ROFO-FORTSCHR RONTG 2012. [DOI: 10.1055/s-0032-1310715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
19
|
Hirntumore und Metastasen. ROFO-FORTSCHR RONTG 2012. [DOI: 10.1055/s-0032-1311375] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
20
|
TrueFISP of the pediatric pineal gland: volumetric and microstructural analysis. Clin Neuroradiol 2011; 22:69-77. [PMID: 22101692 DOI: 10.1007/s00062-011-0110-5] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2011] [Accepted: 10/24/2011] [Indexed: 01/28/2023]
Abstract
PURPOSE Although high-resolution 3D-imaging has markedly improved the imaging of the pediatric pineal gland, the prevalences of typical and atypical cysts as well as in vivo volumes are unknown. The purpose of this study was to compare the frequency of typical and atypical cysts using high-resolution 3D-sequence true fast imaging with steady state precession (trueFISP) and standard sequences and to directly measure the pineal volume in a large pediatric population. METHODS In 54 consecutively examined children (age 0-17 years, mean age 5.4 ± 5.6 years, 44% female, 56% male) the prevalence of typical and atypical cysts (thickened rim, trabeculations, asymmetry) was determined using trueFISP (isotropic, 0.8 mm) and standard sequences, 1.5-T, T1-weighted spin echo (T1-SE), T2-weighted turbo spin echo (T2-TSE) and fluid attenuated inversion recovery (FLAIR). Indistinct findings were noted separately. Volumetry was based on the trueFISP datasets. Solid and cystic compartments were approached separately. The pineal volume was correlated to gender and age. RESULTS The detected frequency of pineal cysts was higher in trueFISP (57.4%) than in standard sequences (T1-SE 7.4%, T2-TSE 14.8%, and FLAIR 13.0%). In trueFISP 66.3% of the detected cysts were classified as atypical (standard sequences 0%). Indistinct findings were lowest in trueFISP. The mean pineal volume was 94.3 ± 159.1 mm³ and no gender related differences were found. Age and volume showed a moderate correlation (r = 0.382) which was remarkably higher in completely solid glands (r = 0.659). CONCLUSIONS TrueFISP imaging improves the detection of pineal cysts in children. A typical cysts are frequently detected as an incidental finding. Volumetric analysis of the pediatric pineal gland is feasible and reveals enormous variation. Whereas gender effects are negligible, the pineal volume in children is dependant on age.
Collapse
|
21
|
Maintained functionality of an implantable radiotelemetric blood pressure and heart rate sensor after magnetic resonance imaging in rats. Physiol Meas 2011; 32:1941-51. [PMID: 22047995 DOI: 10.1088/0967-3334/32/12/005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Radiotelemetric sensors for in vivo assessment of blood pressure and heart rate are widely used in animal research. MRI with implanted sensors is regarded as contraindicated as transmitter malfunction and injury of the animal may be caused. Moreover, artefacts are expected to compromise image evaluation. In vitro, the function of a radiotelemetric sensor (TA11PA-C10, Data Sciences International) after exposure to MRI up to 9.4 T was assessed. The magnetic force of the electromagnetic field on the sensor as well as radiofrequency (RF)-induced sensor heating was analysed. Finally, MRI with an implanted sensor was performed in a rat. Imaging artefacts were analysed at 3.0 and 9.4 T ex vivo and in vivo. Transmitted 24 h blood pressure and heart rate were compared before and after MRI to verify the integrity of the telemetric sensor. The function of the sensor was not altered by MRI up to 9.4 T. The maximum force exerted on the sensor was 273 ± 50 mN. RF-induced heating was ruled out. Artefacts impeded the assessment of the abdomen and thorax in a dead rat, but not of the head and neck. MRI with implanted radiotelemetric sensors is feasible in principal. The tested sensor maintains functionality up to 9.4 T. Artefacts hampered abdominal and throacic imaging in rats, while assessment of the head and neck is possible.
Collapse
|
22
|
Abciximab Does Not Prevent Ischemic Lesions Related to Cerebral Angiography: A Randomized Placebo-Controlled Trial. Cerebrovasc Dis 2011; 31:353-7. [DOI: 10.1159/000323219] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2010] [Accepted: 11/26/2010] [Indexed: 11/19/2022] Open
|
23
|
Abstract
Foreign body ingestion is a common pediatric emergency and if the foreign body cannot be detected radiologically or endoscopically further investigations are required. In this article the case of a radiolucent, ingested foreign body (mini-candleholder of a birthday cake) is presented. The foreign body could not initially be identified via X-ray and endoscopy due to its parapharyngeal localization but was finally visualized by magnetic resonance imaging (MRI) which additionally uncovered the co-existence of acute mediastinal inflammation.
Collapse
|
24
|
Dual-energy CT after peri-interventional subarachnoid haemorrhage: a feasibility study. Clin Neuroradiol 2010; 20:231-5. [PMID: 21052614 DOI: 10.1007/s00062-010-0036-3] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2010] [Accepted: 09/13/2010] [Indexed: 11/26/2022]
Abstract
PURPOSE The aim was to assess the feasibility of dual-energy computed tomography (DE-CT) for detection of peri-interventional re-bleeding in patients with aneurysmal subarachnoid hemorrhage (re-SAH). METHODS For in vitro-analyses DE-CT of partially clotted blood intermixed with fresh blood containing contrast agent was performed. In a clinical setting, 4 patients routinely underwent DE-CT after suspected peri-interventional re-SAH. DE-CT source data images, iodine maps and virtual non-contrast images (VNC) were analyzed and regions-of-interest (ROI) measurements of density values were performed. RESULTS In vitro experiments demonstrated the feasibility of DE-CT to discriminate between blood with and without contrast agent. In all patients peri-interventional re-SAH was confirmed by detection of extravasated iodine within the subarachnoid spaces in post-interventional DE-CT. Dual-energy CT allowed the discrimination of old blood clots of the initial SAH and blood originating from peri-interventional re-SAH. After subtraction of the iodine-related high density signal, VNC images optimized the estimation of the true amount of subarachnoid blood. CONCLUSION Dual-energy CT allows the discrimination and subtraction of blood and iodine mixed within the subarachnoid spaces in patients with peri-interventional re-SAH. It helps to avoid overestimation of SAH after peri-interventional re-bleeding and therefore is a potentially valuable tool in the assessment of peri-interventional re-SAH.
Collapse
|
25
|
Einsatz der „single breath-hold„ Technik für die hochauflösende ultra-schnelle Mikro-CT der thorakalen und abdominellen Organe der lebenden Maus. ROFO-FORTSCHR RONTG 2010. [DOI: 10.1055/s-0030-1268294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
26
|
Mikro-CT-basierte Doppelkontrast-Kolonografie zur Detektion von Kolonpolypen in einem in vivo-Mausmodell. ROFO-FORTSCHR RONTG 2010. [DOI: 10.1055/s-0030-1268340] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
27
|
Ultra-schnelle vCT-Angiografie für die in vivo-Bildgebung der Hirngefäße der Maus. ROFO-FORTSCHR RONTG 2010. [DOI: 10.1055/s-0030-1268318] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
28
|
SOM230 (pasireotide) and temozolomide achieve sustained control of tumour progression and ACTH secretion in pituitary carcinoma with widespread metastases. Exp Clin Endocrinol Diabetes 2010; 118:760-3. [PMID: 20496311 DOI: 10.1055/s-0030-1253419] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
Pituitary carcinomas are rare and neurosurgically challenging lesions, as they commonly relapse after surgical removal. Their prognosis is dismal due to their limited response to radiotherapy and chemotherapy. In recent studies, temozolomide was administered in very few patients with partial effects. We report a patient with an ACTH-secreting pituitary carcinoma and widespread intracranial, spinal and systemic metastases despite repeated surgical treatment, bilateral adrenalectomy, medical treatment and radiotherapy. Additionally to chemotherapy with temozolomide, the patient received SOM230 as salvage therapy with an improvement of the patient's clinical status, and a reduction of ACTH levels. After 12 months of combination therapy a sustained tumor control was achieved and persisted upon monotherapy with SOM230 for more than 9 months thereafter. Thus, temozolomide in combination with SOM230 seems to be promising in patients with ACTH-secreting metastasized pituitary carcinoma.
Collapse
|
29
|
Improved method for the intracerebral engraftment of tumour cells and intratumoural treatment using a guide screw system in mice. Acta Neurochir (Wien) 2003; 145:777-81; discussion 781. [PMID: 14505105 DOI: 10.1007/s00701-003-0091-5] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Orthotopic in vivo models for the experimental treatment of malignant gliomas have become indispensable to evaluate the efficacy of novel therapeutic regimens. Recently, a guide screw system was introduced which is implanted into the cranium of small rodents where it facilitates fast, repeated and exactly reproducible intracerebral injections, avoiding time consuming stereotactic procedures. Here we report our experience with this system, and describe several modifications which we introduced to improve its reliability and to simplify its application. FINDINGS The most important modification made was the optimization of the guide screw implantation site, which needs to be adapted to the age of the mice. Other improvements were the fixation of the guide screw to the cranium of the mice using a two component adhesive. This avoids the tendency, when daily intratumoural injections are performed over several weeks, for the screw to loosen, making precise injections impossible. The injection procedure, initially described as a free-hand approach, was improved by mounting the syringe to a Greenberg retractor. This provided additional stability and speeded up the process. Applying this modified technique, we were able to achieve reproducible results with regard to engraftment rate, tumour growth, and intratumoural treatment in immunocompromized mice. INTERPRETATION We introduced several major and some minor improvements to make working with the guide screw system more reliable, faster and more comfortable. Daily injections over a period of three weeks using this system are feasible and well tolerated by mice.
Collapse
|
30
|
Glioblastoma and cerebral microvascular endothelial cell migration in response to tumor-associated growth factors. Neurosurgery 2003; 52:1391-9; discussion 1399. [PMID: 12762884 DOI: 10.1227/01.neu.0000064806.87785.ab] [Citation(s) in RCA: 111] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2002] [Accepted: 01/28/2003] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVE Glioma cell migration is determined by a complex interplay between soluble motogens and extracellular matrix components. Several growth factors are thought to be involved in glioma cell migration; however, little is known about their motogenic potency relative to one another. METHODS Using modified Boyden chamber assays, we compared the chemotactic effects of scatter factor/hepatocyte growth factor (SF/HGF), transforming growth factor (TGF)-alpha, TGF-beta1, TGF-beta2, epidermal growth factor (EGF), fibroblast growth factor (FGF)-1, FGF-2, insulin-like growth factor (IGF)-1, IGF-2, platelet-derived growth factor (PDGF)-AA, PDGF-BB, vascular endothelial growth factor (VEGF), pleiotrophin (PTN), and midkine (MK) in concentrations ranging from 1 pmol/L to 50 nmol/L on three different human glioblastoma cell lines. Checkerboard analyses distinguished between chemotaxis and chemokinesis. We further investigated the motogenic effects on human cerebral microvascular endothelial cells and analyzed receptor expression profiles. RESULTS SF/HGF was the most potent chemotactic factor for all three glioblastoma cell lines, inducing up to 33-fold stimulation of migration. TGF-alpha showed the second strongest effect (up to 17-fold stimulation), and FGF-1 was also chemotactic for all three glioblastoma cell lines analyzed (maximal 4-fold effect). EGF, FGF-2, IGF-1, IGF-2, TGF-beta1, and TGF-beta2 were chemotactic for one or two of the cell lines (2- to 4-fold effects), whereas PDGF-AA, PDGF-BB, VEGF, PTN, and MK had no effect. In contrast, the most potent stimulators of cerebral microvascular endothelial cell migration were PDGF-AA (4-fold) and PDGF-BB (6-fold). CONCLUSION The expression levels of SF/HGF and TGF-alpha as well as their respective receptors, MET and EGFR, are known to correlate with glioma malignancy grade. The particularly strong motogenic effects of these two growth factors suggest that they could be promising targets for an antimigratory component of glioma therapy, at least in comparison with the 12 other factors that were analyzed.
Collapse
|
31
|
Abstract
INTRODUCTION Platelet function may be influenced by cigarette smoking. We therefore examined the effect of smoking on platelet hemostasis capacity (PHC) with an in vitro analyzer (PFA-100). METHODS AND RESULTS Healthy blood donors (n=54) were included in the study and divided into four groups: nonsmoking males (n=14), nonsmoking females (n=14), smoking males (n=12) and smoking females (n=14). For in vitro analyses, in each participant citrated blood (3.2% buffered) was tested for PHC by two cartridges coated with collagen, and additionally with epinephrine (Col/Epi) or ADP (Col/ADP). Analyses were performed within 4 h after sample taking. PHC was expressed as the time in seconds to occlude the cartridge (closure time, CT). The average CT was significantly prolonged in female smokers compared to the female nonsmoking group for both types of cartridges (Col/Epi: P=.02; Col/ADP: P=.03). No significant differences were detected comparing the CT of smoking and nonsmoking males. After pooling male and female smokers and nonsmokers, no significant differences could be found, neither for the Col/Epi cartridges nor the Col/ADP cartridges. Plaletet aggregation assays performed in parallel showed no significant differences, except a reduced aggregability in male smokers compared to male nonsmokers using epinephrine 8.0 microM/ml as activating agent (P=.01). Furthermore, smoking volunteers presented with a significantly increased fibrinogen level compared to nonsmoking volunteers (P<.01). CONCLUSIONS The results of our study show that in habitual smokers PHC (PFA-100) and the capability of platelets to react upon agonist stimulation in aggregation assays is not significantly influenced or increased compared to healthy nonsmokers. However, an immediate effect of cigarette smoking cannot be excluded.
Collapse
|
32
|
Inhibition of glioma angiogenesis and growth in vivo by systemic treatment with a monoclonal antibody against vascular endothelial growth factor receptor-2. Cancer Res 2001; 61:6624-8. [PMID: 11559524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/21/2023]
Abstract
Using an orthotopic intracerebral model, we investigated whether systemic treatment with DC101, a monoclonal antibody against vascular endothelial growth factor receptor (VEGFR)-2, could inhibit angiogenesis and the growth of human glioblastoma cells in severe combined immunodeficient mice. Intraperitoneal treatment with DC101, control IgG, or PBS was initiated either on day 0 or, in another series, on day 6 after tumor cell implantation, and animals were killed approximately 2 weeks after tumor cell injection. Tumor volumes in animals treated with DC101 were reduced by 59 and 81% compared with IgG and PBS controls, respectively (P < 0.001), when treatment was initiated immediately, and similar results were obtained when treatment started on day 6. Microvessel density in tumors of DC101-treated animals was reduced by at least 40% compared with animals treated with control IgG or PBS (P < 0.01). We observed a reduction in tumor cell proliferation and an increase in apoptosis in DC101-treated animals (P < 0.001). However, in mice treated with DC101, we also noticed a striking increase in the number and total area of small satellite tumors clustered around, but distinct from, the primary. These satellites usually contained central vessel cores, and tumor cells often had migrated over long distances along the host vasculature to eventually reach the surface and spread leptomeningeally. We conclude that systemic antagonization of VEGFR-2 can inhibit glioblastoma neovascularization and growth but can lead to increased cooption of preexistent cerebral blood vessels. Therefore, a combination of different treatment modalities which also include anti-invasive therapy may be needed for an effective therapy against glioblastoma, and the use of an antibody against VEGFR-2 may be one effective component.
Collapse
|