1
|
Identifying Slim Modiolar Electrode Tip Fold-Over With Intracochlear Electrocochleography. Otolaryngol Head Neck Surg 2024; 170:1124-1132. [PMID: 38018567 PMCID: PMC10960700 DOI: 10.1002/ohn.587] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 10/21/2023] [Accepted: 10/28/2023] [Indexed: 11/30/2023]
Abstract
OBJECTIVE To evaluate the predictive value of intracochlear electrocochleography (ECochG) for identifying tip fold-over during cochlear implantation (CI) using the slim modiolar electrode (SME) array. STUDY DESIGN Prospective cohort study. SETTING Tertiary referral center. METHODS From July 2022 to June 2023, 142 patients, including adults and children, underwent intracochlear ECochG monitoring during and after SME placement. Tone-bursts were presented from 250 Hz to 2 kHz at 108 to 114 dB HL. A fast Fourier transform (FFT) allowed for frequency-specific evaluation of ECochG response. ECochG patterns during insertion and postinsertion were evaluated using sensitivity and specificity analysis to predict tip fold-over. Intraoperative plain radiographs served as a reference standard. RESULTS Fifteen tip fold-over cases occurred (10.6%) with significant ECochG response (>2 µV). Sixty-one cases without tip fold-over occurred (43.0%) with significant ECochG response. All tip fold-overs had both a nontonotopic postinsertion sweep and nonrobust active insertion pattern. No patients with robust insertion or tonotopic sweep patterns had tip fold-over. Sensitivity of detecting tip fold-over when having both nonrobust insertion and nontonotopic sweep patterns was 100% (95% confidence inteval [CI] 78.2%-100%), specificity was 68.9% (95% CI 55.7%-80.1%), and the overall accuracy was 72.0% (95% CI 60.5%-81.7%). CONCLUSION Intracochlear ECochG monitoring during cochlear implantation with the SME can be a valuable tool for identifying properly positioned electrode arrays. In cases where ECochG patterns are nonrobust on insertion and nontonotopic for electrode sweeps, there may be a concern for tip fold-over, and intraoperative imaging is necessary to confirm proper insertion.
Collapse
|
2
|
Individual Patient Comorbidities and Effect on Cochlear Implant Performance. Otol Neurotol 2024; 45:e281-e288. [PMID: 38437816 PMCID: PMC10939851 DOI: 10.1097/mao.0000000000004144] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/06/2024]
Abstract
OBJECTIVE To examine the association between preoperative comorbidities and cochlear implant speech outcomes. STUDY DESIGN Retrospective cohort. SETTING Tertiary referral center. PATIENTS A total of 976 patients who underwent cochlear implantation (CI) between January 2015 and May 2022. Adult patients with follow-up, preoperative audiologic data, and a standardized anesthesia preoperative note were included. EXPOSURE Adult Comorbidity Evaluation 27 (ACE-27) based on standardized anesthesia preoperative notes. MAIN OUTCOME MEASURES Postoperative change in consonant-nucleus-consonant (CNC) score, AzBio Sentence score in quiet, and AzBio + 10 dB signal-to-noise ratio (SNR). Sentence score of the implanted ear at 3, 6, and 12 months. RESULTS A total of 560 patients met inclusion criteria; 112 patients (20%) had no comorbidity, 204 patients (36.4%) had mild comorbidities, 161 patients (28.8%) had moderate comorbidities, and 83 patients (14.8%) had severe comorbidities. Mixed model analysis revealed all comorbidity groups achieved a clinically meaningful improvement in all speech outcome measures over time. This improvement was significantly different between comorbidity groups over time for AzBio Quiet ( p = 0.045) and AzBio + 10 dB SNR ( p = 0.0096). Patients with severe comorbidities had worse outcomes. From preop to 12 months, the estimated marginal mean difference values (95% confidence interval) between the no comorbidity group and the severe comorbidity group were 52.3 (45.7-58.9) and 32.5 (24.6-40.5), respectively, for AzBio Quiet; 39.5 (33.8-45.2) and 21.2 (13.6-28.7), respectively, for AzBio + 10 dB SNR; and 43.9 (38.7-49.0) and 31.1 (24.8-37.4), respectively, for CNC. CONCLUSIONS Comorbidities as assessed by ACE-27 are associated with CI performance. Patients with more severe comorbidities have clinically meaningful improvement but have worse outcome compared to patients with no comorbidities.
Collapse
|
3
|
Single-cell multi-omic analysis of the vestibular schwannoma ecosystem uncovers a nerve injury-like state. Nat Commun 2024; 15:478. [PMID: 38216553 PMCID: PMC10786875 DOI: 10.1038/s41467-023-42762-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2022] [Accepted: 10/10/2023] [Indexed: 01/14/2024] Open
Abstract
Vestibular schwannomas (VS) are benign tumors that lead to significant neurologic and otologic morbidity. How VS heterogeneity and the tumor microenvironment (TME) contribute to VS pathogenesis remains poorly understood. In this study, we perform scRNA-seq on 15 VS, with paired scATAC-seq (n = 6) and exome sequencing (n = 12). We identify diverse Schwann cell (SC), stromal, and immune populations in the VS TME and find that repair-like and MHC-II antigen-presenting SCs are associated with myeloid cell infiltrate, implicating a nerve injury-like process. Deconvolution analysis of RNA-expression data from 175 tumors reveals Injury-like tumors are associated with larger tumor size, and scATAC-seq identifies transcription factors associated with nerve repair SCs from Injury-like tumors. Ligand-receptor analysis and in vitro experiments suggest that Injury-like VS-SCs recruit myeloid cells via CSF1 signaling. Our study indicates that Injury-like SCs may cause tumor growth via myeloid cell recruitment and identifies molecular pathways that may be therapeutically targeted.
Collapse
|
4
|
Factors Affecting Performance in Adults With Cochlear Implants: A Role for Cognition and Residual Cochlear Function. Otol Neurotol 2023; 44:988-996. [PMID: 37733968 PMCID: PMC10840600 DOI: 10.1097/mao.0000000000004015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/23/2023]
Abstract
OBJECTIVE To evaluate the impact of preoperative and perioperative factors on postlinguistic adult cochlear implant (CI) performance and design a multivariate prediction model. STUDY DESIGN Prospective cohort study. SETTING Tertiary referral center. PATIENTS AND INTERVENTIONS Two hundred thirty-nine postlinguistic adult CI recipients. MAIN OUTCOME MEASURES Speech-perception testing (consonant-nucleus-consonant [CNC], AzBio in noise +10-dB signal-to-noise ratio) at 3, 6, and 12 months postoperatively; electrocochleography-total response (ECochG-TR) at the round window before electrode insertion. RESULTS ECochG-TR strongly correlated with CNC word score at 6 months ( r = 0.71, p < 0.0001). A multivariable linear regression model including age, duration of hearing loss, angular insertion depth, and ECochG-TR did not perform significantly better than ECochG-TR alone in explaining the variability in CNC. AzBio in noise at 6 months had moderate linear correlations with Montreal Cognitive Assessment (MoCA; r = 0.38, p < 0.0001) and ECochG-TR ( r = 0.42, p < 0.0001). ECochG-TR and MoCA and their interaction explained 45.1% of the variability in AzBio in noise scores. CONCLUSIONS This study uses the most comprehensive data set to date to validate ECochG-TR as a measure of cochlear health as it relates to suitability for CI stimulation, and it further underlies the importance of the cochlear neural substrate as the main driver in speech perception performance. Performance in noise is more complex and requires both good residual cochlear function (ECochG-TR) and cognition (MoCA). Other demographic, audiologic, and surgical variables are poorly correlated with CI performance suggesting that these are poor surrogates for the integrity of the auditory substrate.
Collapse
|
5
|
Cognitive Assessment in Elderly Cochlear Implant Recipients: Long-Term Analysis. Laryngoscope 2023; 133:2379-2387. [PMID: 36300628 DOI: 10.1002/lary.30466] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 08/23/2022] [Accepted: 09/20/2022] [Indexed: 08/11/2023]
Abstract
OBJECTIVES To examine long-term speech and cognition outcomes in older adult cochlear implant (CI) recipients. First, by evaluating if CI performance was maintained over an extended follow-up period regardless of preoperative cognitive status. Secondly, by evaluating if there was a difference in the rate of cognitive decline between preoperative mild and normal cognition following CI over an extended period of time. STUDY DESIGN AND SETTING Retrospective cohort study. METHODS CI recipients ≥65 years of age implanted between 2009 and 2014 with 4+ years follow up. Pre- and postoperative audiometric and speech outcome assessments were collected. Cognitive status was measured using the mini mental status examination (MMSE) at numerous time points. RESULTS Fifty-three patients met inclusion. Patients were divided into two groups based on preoperative MMSE with scores considered normal (28-30) and those with mildly impaired cognition (MIC, scores 25-27). Audiometric and speech performance improved significantly at one-year post implantation and this was maintained without significant change at 4+ years, regardless of cognitive status. Mixed modeling analysis controlling for age demonstrated no significant difference in the rate of cognitive decline at 4+ years post implantation between the normal cognition cohort (1.74; 95%CI 0.89-2.6) and MIC (2.9; 95%1.91-3.88). CONCLUSION Speech performance was significantly improved and sustained after CI in both normal cognition and MIC patients. The rate of cognitive decline in older adult CI patients appears to be similar regardless of preoperative cognitive status. Although results demonstrate rates of cognitive decline following CI did not differ between cognition groups over 4+ years, future studies will need to further investigate this over extended time periods with a more comprehensive cognitive testing battery. LEVEL OF EVIDENCE 4 Laryngoscope, 133:2379-2387, 2023.
Collapse
|
6
|
One-Year Hearing Preservation and Speech Outcomes Comparing Slim Modiolar and Lateral Wall Arrays. Otolaryngol Head Neck Surg 2023; 169:340-347. [PMID: 36814321 DOI: 10.1002/ohn.273] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 12/28/2022] [Accepted: 01/02/2023] [Indexed: 02/24/2023]
Abstract
OBJECTIVE Compare postoperative speech outcomes in hearing preservation (HP) cochlear implantation (CI) patients with a low-frequency pure-tone average (LFPTA) ≤ 60 dB using 2 electrode array designs. STUDY DESIGN Retrospective cohort study. SETTING Large academic cochlear implant referral center. METHODS We reviewed adult HP CI cases using either the slim modiolar electrode (SME) (CI 532/CI 632) or th slim lateral wall electrode (SLWE) (CI 624). One-year speech outcomes and HP status were the primary outcomes. RESULTS A total of 132 implanted ears were analyzed (mean age 73.1 years, standard deviation [SD] 12.6), with 72% (N = 95) with CI 532/632 and 28% (N = 37) with CI 624. The mean preoperative LFPTA was 44.8 dB, SD 11.8. One-year functional HP was 27.2% (mean LFPTA shift 46.1 dB, SD 22.1) and was as follows: SME 23.9% and SLWE 36.4%, p = .168. The mean age at implantation was significantly younger only in SLWE patients with preserved hearing (66.9 vs 80.3 years, p = .008). At 6 months, speech measures were significantly better in all outcomes in HP patients with an SLWE than nonpreserved SLWE patients; this effect abated at 1 year as performance among nonpreserved SLWE patients became equivalent to the remaining cohort. Speech outcomes in SME patients were similar regardless of HP status. Age at implantation and datalogging was correlated with speech outcomes. CONCLUSION In this cohort of HP patients, a 1-year functional HP rate of 23.9% (SME) and 36.4% (SLWE) was observed (p = 0.168). This was initially 57.1% (SME) and 70.3% (SLWE) at activation, p = .172. Datalogging and age at implantation were correlated with postoperative speech outcomes.
Collapse
|
7
|
Predictors of Short-Term Changes in Quality of Life after Cochlear Implantation. Otol Neurotol 2023; 44:e146-e154. [PMID: 36728163 PMCID: PMC9928883 DOI: 10.1097/mao.0000000000003805] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
OBJECTIVE This study aimed 1) to measure the effect of cochlear implantation on health-related quality of life (HR-QOL) using the Cochlear Implant Quality of Life (CIQOL) questionnaire and 2) to determine audiologic, demographic, and non-CI/hearing-related QOL factors influencing the CIQOL. STUDY DESIGN Prospective observational study. SETTING Tertiary referral center. PATIENTS AND INTERVENTIONS Thirty-seven adult patients with sensorineural hearing loss undergoing cochlear implantation. MAIN OUTCOME MEASURES CIQOL-global score preimplantation and 6 months postimplantation. Physical function score as measured by the short-form survey, audiologic, and demographic variables. RESULTS CIQOL showed significant improvement from preimplantation to 6 months postactivation with a mean difference of 14.9 points (95% confidence interval, 11.3 to 18.5, p < 0.0001). Improvement in CIQOL (ΔCIQOL) correlated linearly with age ( r = -0.49, p = 0.001) and improvement in speech perception testing ( r = 0.63, p < 0.0001). Multivariate modeling using age and change in consonant-vowel nucleus-consonant (CNC) score explained 46% of the variability measured by the ΔCIQOL-global score. CONCLUSIONS Nearly all CI recipients achieve significant gains for all domains as measured by the CIQOL. However, younger patients and those with a greater improvement in speech perception performance (CNC) are more likely to achieve a greater CIQOL benefit. Results here suggest the importance of considering preoperative CIQOL and speech perception measures when evaluating predictors of HR-QOL.
Collapse
|
8
|
Incidence and Management of Facial Paralysis After Skull Base Trauma, an Administrative Database Study. Otol Neurotol 2022; 43:e1180-e1186. [PMID: 36214506 PMCID: PMC9649848 DOI: 10.1097/mao.0000000000003721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
OBJECTIVE Report the incidence of and treatment patterns for facial nerve palsy after skull base fracture. STUDY DESIGN Retrospective cohort study. SETTING IBM MarketScan Commercial Database (2006-2019). PATIENTS Human subjects with skull base fracture, per International Classification of Diseases-9th and 10th Revisions-Clinical Modification diagnosis codes. MAIN OUTCOME MEASURES The primary outcomes were the incidence and median time to facial nerve palsy diagnosis within 30 days of skull base fracture. Secondary outcomes were treatments (corticosteroids, antivirals, facial nerve decompression, botulinum toxin, and facial reanimation), demographics, and rates of hearing loss, vertigo, tympanic membrane rupture, cerebrospinal fluid leak, comorbidities, and loss of consciousness. RESULTS The 30-day incidence of facial nerve palsy after skull base trauma was 1.0% (738 of 72,273 patients). The median (95% confidence interval [CI]) time to diagnosis was 6 (6-7) days, and only 22.9% were diagnosed within 1 day. There were significantly higher rates (risk difference, 95% CI) of hearing loss (26%, 22-29%), tympanic membrane rupture (6.3%, 4.5-8.1%), cerebrospinal fluid leak (6.4%, 4.5-8.3%), comorbidity (14%, 10.4-17.6%), and loss of consciousness (24.3%, 20.7-27.9%). Loss of consciousness was associated with longer median (95% CI) time to facial nerve palsy diagnosis: 10 (9-10) days. Corticosteroids were the most common treatment but only reported for less than one-third of patients. Only eight patients underwent facial nerve decompression. CONCLUSIONS Facial nerve palsy after skull base fracture is associated with higher comorbidity, and the diagnosis is often delayed. Few patients were treated with surgery, and there are inconsistencies in the types and timing of treatments.
Collapse
|
9
|
External Validation of Cochlear Implant Screening Tools Demonstrates Modest Generalizability. Otol Neurotol 2022; 43:e1000-e1007. [PMID: 36047695 PMCID: PMC9481700 DOI: 10.1097/mao.0000000000003678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
OBJECTIVE To assess the clinical application of five recently published cochlear implant (CI) candidacy evaluation (CICE) referral screening tools through external validation. STUDY DESIGN Retrospective cohort study. SETTING Tertiary otology/neurotology practice. PATIENTS Adults who underwent CICE between December 2020 and September 2021. INTERVENTIONS CICE referral screening tools versus CI candidacy criteria. MAIN OUTCOME MEASURES CICE screening tool performance, based on the ability to identify patients who met the CI candidacy criteria, was evaluated. CI candidacy criteria were defined as best-aided AzBio sentences at +10 signal-to-noise ratio and either 60% or less accuracy to reflect traditional criteria used in clinical settings or 40% or less accuracy (only patients 65 years or older) to reflect Medicare-eligible criteria. RESULTS Screening criteria of proposed CICE referral tools vary widely across pure-tone average and word recognition scores. When screened by traditional criteria, the sensitivities and specificities of these referral tools varied from 40 to 77% and from 22 to 86%, respectively. When screened by Medicare-eligible criteria, sensitivities and specificities varied from 41 to 81% and from 24 to 91%, respectively. The screening tool proposed by Zwolan et al. ( Otol Neurotol 2020;41(7):895-900) demonstrated the best overall performance for traditional (Youden's J , 0.37; sensitivity, 62%; specificity, 75%) and Medicare-eligible patients (Youden's J , 0.44; sensitivity, 66%; specificity, 78%). All screening tools performed worse on the validation cohort compared with their respective development cohorts. CONCLUSIONS Current tools for determining CICE referral have diverse screening criteria. These combinations of pure-tone average and word recognition score are modestly successful at identifying CI candidates.
Collapse
|
10
|
Promontory Electrocochleography Recordings to Predict Speech-Perception Performance in Cochlear Implant Recipients. Otol Neurotol 2022; 43:915-923. [PMID: 35861658 PMCID: PMC9621328 DOI: 10.1097/mao.0000000000003628] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE 1) To determine the relationship of electrocochleography (ECochG) responses measured on the promontory with responses measured at the round window (RW) and various intracochlear sites. 2) To evaluate if promontory ECochG responses correlate with postoperative speech-perception performance using the cochlear implant (CI). STUDY DESIGN Prospective cohort study. SETTING Tertiary referral center. PATIENTS AND INTERVENTIONS Ninety-six adult CI recipients with no cochlear malformations or previous otologic surgery. MAIN OUTCOME MEASURES Acoustically evoked ECochG responses were measured intraoperatively at both extracochlear and intracochlear locations. ECochG total response (ECochG-TR), a measure of residual cochlear function, was calculated by summing the fast Fourier transformation amplitudes in response to 250-Hz to 2-kHz acoustic stimuli. Speech-perception performance was measured at 3 months. RESULTS There were strong linear correlations for promontory ECochG-TR with the ECochG-TRs measured at the RW ( r = 0.95), just inside scala tympani ( r = 0.91), and after full insertion ( r = 0.83). For an individual subject, the morphology of the ECochG response was similar in character across all positions; however, the response amplitude increased from promontory to RW (~1.6-fold) to just inside scala tympani (~2.6-fold), with the largest response at full insertion (~13.1-fold). Promontory ECochG-TR independently explained 51.8% of the variability ( r2 ) in consonant-nucleus-consonant at 3 months. CONCLUSIONS Promontory ECochG recordings are strongly correlated with responses previously recorded at extracochlear and intracochlear sites and explain a substantial portion of the variability in CI performance. These findings are a critical step in supporting translation of transtympanic ECochG into the clinic preoperatively to help predict postoperative CI performance.
Collapse
|
11
|
Early Hearing Preservation Outcomes Following Cochlear Implantation With New Slim Lateral Wall Electrode Using Electrocochleography. Otol Neurotol 2022; 43:443-451. [PMID: 35170555 PMCID: PMC8959404 DOI: 10.1097/mao.0000000000003475] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE Describe early hearing preservation (HP) cochlear implantation (CI) outcomes using a new slim lateral wall electrode (SLWE). STUDY DESIGN Prospective cohort study. SETTING Tertiary referral center. PATIENTS Adult CI candidates with preoperative low-frequency pure-tone average (LFPTA; 125, 250, 500 Hz) ≤60 dB HL. INTERVENTION CI with and without intracochlear real-time electrocochleography (RT-ECochG). MAIN OUTCOME MEASURE HP (LFPTA ≤80 dB HL), LFPTA shift, speech-perception performance measures, postoperative CT reconstruction. RESULTS Forty-two subjects were implanted with the SLWE. Thirty patients underwent full insertion without RT-ECochG feedback, and HP was maintained at 3-months postactivation for 7 (23.3%) patients with mean LFPTA shift of 57.5 ± 25.6 dB HL. RT-ECochG feedback was utilized on 12 patients, of whom 6 patients had full insertions and 6 patients had anywhere from 1 to 3 electrodes left outside of the cochlea based on RT-ECochG feedback. At 3 months postoperatively, HP was achieved on 10 (83.3%) patients and mean LFPTA shift was 18.9 c 11.7 dB HL. Mean difference between LFPTA threshold shift at 3-months postactivation with and without RT-ECochG was 38.6 dB HL (95% CI, 25.6-51.67). There was an improvement in delta CNC from preoperative to 3-months postactivation when using RT-ECochG, with mean difference 20.7% (95% CI, 3.3-38.1). CONCLUSIONS Use of RT-ECochG monitoring during SLWE placement results in fewer full electrode insertions and significantly better HP rates and speech-perception outcomes when compared with unmonitored insertions. Further investigation is needed to evaluate long-term audiologic outcomes to better understand the relationships among ECochG, cochlear trauma, functional outcomes, and HP.
Collapse
|
12
|
Electrocochleography and cognition are important predictors of speech perception outcomes in noise for cochlear implant recipients. Sci Rep 2022; 12:3083. [PMID: 35197556 PMCID: PMC8866505 DOI: 10.1038/s41598-022-07175-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Accepted: 02/10/2022] [Indexed: 11/15/2022] Open
Abstract
Although significant progress has been made in understanding outcomes following cochlear implantation, predicting performance remains a challenge. Duration of hearing loss, age at implantation, and electrode positioning within the cochlea together explain ~ 25% of the variability in speech-perception scores in quiet using the cochlear implant (CI). Electrocochleography (ECochG) responses, prior to implantation, account for 47% of the variance in the same speech-perception measures. No study to date has explored CI performance in noise, a more realistic measure of natural listening. This study aimed to (1) validate ECochG total response (ECochG-TR) as a predictor of performance in quiet and (2) evaluate whether ECochG-TR explained variability in noise performance. Thirty-five adult CI recipients were enrolled with outcomes assessed at 3-months post-implantation. The results confirm previous studies showing a strong correlation of ECochG-TR with speech-perception in quiet (r = 0.77). ECochG-TR independently explained 34% of the variability in noise performance. Multivariate modeling using ECochG-TR and Montreal Cognitive Assessment (MoCA) scores explained 60% of the variability in speech-perception in noise. Thus, ECochG-TR, a measure of the cochlear substrate prior to implantation, is necessary but not sufficient for explaining performance in noise. Rather, a cognitive measure is also needed to improve prediction of noise performance.
Collapse
|
13
|
Is Characteristic Frequency Limiting Real-Time Electrocochleography During Cochlear Implantation? Front Neurosci 2022; 16:915302. [PMID: 35937872 PMCID: PMC9354607 DOI: 10.3389/fnins.2022.915302] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2022] [Accepted: 06/15/2022] [Indexed: 12/05/2022] Open
Abstract
Objectives Electrocochleography (ECochG) recordings during cochlear implantation have shown promise in estimating the impact on residual hearing. The purpose of the study was (1) to determine whether a 250-Hz stimulus is superior to 500-Hz in detecting residual hearing decrement and if so; (2) to evaluate whether crossing the 500-Hz tonotopic, characteristic frequency (CF) place partly explains the problems experienced using 500-Hz. Design Multifrequency ECochG comprising an alternating, interleaved acoustic complex of 250- and 500-Hz stimuli was used to elicit cochlear microphonics (CMs) during insertion. The largest ECochG drops (≥30% reduction in CM) were identified. After insertion, ECochG responses were measured using the individual electrodes along the array for both 250- and 500-Hz stimuli. Univariate regression was used to predict whether 250- or 500-Hz CM drops explained low-frequency pure tone average (LFPTA; 125-, 250-, and 500-Hz) shift at 1-month post-activation. Postoperative CT scans were performed to evaluate cochlear size and angular insertion depth. Results For perimodiolar insertions (N = 34), there was a stronger linear correlation between the largest ECochG drop using 250-Hz stimulus and LFPTA shift (r = 0.58), compared to 500-Hz (r = 0.31). The 250- and 500-Hz CM insertion tracings showed an amplitude peak at two different locations, with the 500-Hz peak occurring earlier in most cases than the 250-Hz peak, consistent with tonotopicity. When using the entire array for recordings after insertion, a maximum 500-Hz response was observed 2-6 electrodes basal to the most-apical electrode in 20 cases (58.9%). For insertions where the apical insertion angle is >350 degrees and the cochlear diameter is <9.5 mm, the maximum 500-Hz ECochG response may occur at the non-apical most electrode. For lateral wall insertions (N = 14), the maximum 250- and 500-Hz CM response occurred at the most-apical electrode in all but one case. Conclusion Using 250-Hz stimulus for ECochG feedback during implantation is more predictive of hearing preservation than 500-Hz. This is due to the electrode passing the 500-Hz CF during insertion which may be misidentified as intracochlear trauma; this is particularly important in subjects with smaller cochlear diameters and deeper insertions. Multifrequency ECochG can be used to differentiate between trauma and advancement of the apical electrode beyond the CF.
Collapse
|
14
|
Abstract
OBJECTIVE To evaluate the impact of different open set sentence recognition tests in quiet, +10 dB signal to noise ratio (SNR), and +5 dB SNR in adult cochlear implant (CI) recipients above and below 65 years of age. STUDY DESIGN AND SETTING Multi-institution, prospective, non-randomized, single-subject repeated measures design. PATIENTS Ninety six adults more than or equal to 18 years old with postlingual bilateral sensorineural hearing loss. INTERVENTIONS Participants received a CI532 in one ear. Speech perception measures were evaluated before and 6-months after activation. MAIN OUTCOME MEASURES Subjects completed consonant-nucleus-constant (CNC) words in quiet and AzBio sentences in noise using +10 and +5 dB SNR, and Montreal Cognitive Assessment (MOCA). RESULTS Ninety six adult patients were enrolled (n = 70 older [≥65 yr], n = 26 younger [<65 yr]). There was no difference in CNC scores (CI alone 58.4% versus 67.5%, p = 0.0857; best aided 66.7% versus 76.1%, p = 0.3357). Older adults performed worse on AzBio +10 dB SNR compared with younger patients (CI alone 37.4% versus 56.9%, p = 0.0006; best aided 51.4% versus 68.2%; p = 0.01), and in AzBio +5 dB SNR (CI alone 7.7% versus 11.2%, p = 0.0002; best aided 15.3% versus 22.3%, p = 0.0005). The magnitude of change in AzBio +10 dB SNR was significantly less in older adults in CI alone (15.3% versus 22.3%; p = 0.0493) but not best aided (21.5% versus 31.3%; p = 0.105). The magnitude of change was drastically worse in AzBio +5 dB SNR for older adults (CI alone 6.7% versus 22.1%, p = 0.0014; best aided 9.5% versus 21.5%; p = 0.0142). There was no significant difference in MOCA between the two age groups. CONCLUSIONS While both older and younger patients have similar outcomes with respect to CNC word scores in quiet, the addition of noise disproportionally impacts older patients. Caution should be exercised testing the elderly in noise; testing in noise may disproportionally impact performance expectations and should be more carefully considered when used for candidacy criteria and counseling. Future studies need to further investigate the disproportionate effect of noise on candidacy testing and its impact on how elderly patients are qualified.
Collapse
|
15
|
Differences in Force Levels, Word Recognition in Quiet, Sentence Reception Threshold in Noise, and Subjective Outcomes for a Bone-Anchored Hearing Device Programmed Using Manufacturer First-Fit, Aided Sound-Field Thresholds and Programmed to DSL-BCD Using a Skull Simulator. J Am Acad Audiol 2021; 32:395-404. [PMID: 34847581 DOI: 10.1055/s-0041-1730412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
BACKGROUND Best practice guidelines for verifying fittings of bone-anchored hearing devices (BAHD) recommend using aided sound-field thresholds (ASFT), but express caution regarding the variables impacting obtaining valid and reliable ASFTs.1 Recently, a skull simulator was introduced to facilitate programming BAHD devices in force level (FL) to desired sensation level-bone conduction devices (skull simulator/DSL-BCD)2 3 targets in a hearing aid analyzer. Currently, no evidence is available reporting if differences in measured FL using the manufacturer first-fit (FF) and word recognition in quiet, sentence reception threshold in noise, and subjective outcomes are present for a BAHD programmed using ASFT versus programmed using skull simulator/DSL-BCD targets. PURPOSE The aim of this study was to examine if significant differences were present in FL using the FF and word recognition in quiet at 50 and 65 decibel of sound pressure level (dB SPL), sentence reception threshold in noise and subjective outcomes using the abbreviated profile of hearing aid benefit (APHAB), and speech, spatial, and qualities of hearing (SSQ) between a BAHD fit using ASFT or skull simulator/DSL-BCD targets. RESEARCH DESIGN A double-blind randomized crossover design with 15 adults having unilateral sensorineural hearing loss. All participants were successful users of the Cochlear America Baha 5. DATA COLLECTION AND ANALYSIS Baha Power 5 devices were fit using FF, ASFT, and skull simulator/DSL-BCD targets. Order of the three fitting strategies was randomly assigned and counter-balanced. RESULTS No significant differences were found for a BAHD device programmed using ASFT versus skull simulator/DSL-BCD targets for consonant-nucleus-consonant words in quiet at 50 or 65 dB SPL, sentence reception threshold in noise, the APHAB or SSQ. There were, however, significant differences, at primarily 500 to 2,000 Hz in measured FLs between the FF, ASFT, and skull simulator/DSL-BCD targets at 50 and 65 dB SPL. CONCLUSIONS There were no significant differences in subject performance with two speech measures and subjective responses to two questionnaires for BAHD fittings using ASFT versus using skull simulator/DSL-BCD targets. Differences in FL between the three fitting strategies were present primarily at 500 to 2,000 Hz. Limitations of the study are highlighted along with situations where the skull simulator can play a significantly beneficial role when fitting BAHD devices.
Collapse
|
16
|
Clinical Staging to Estimate the Probability of Severe Postoperative Complications in Patients With Vestibular Schwannoma. JAMA Otolaryngol Head Neck Surg 2021; 147:991-998. [PMID: 34617972 DOI: 10.1001/jamaoto.2021.2626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Importance Vestibular schwannomas have long been treated as a homogeneous entity. Clinical symptoms at presentation may help elucidate the underlaying pathophysiologic characteristics of tumor subtypes. Describing the heterogeneity of these benign tumors may assist in predicting clinical outcomes associated with their treatment. Objective To create a tumor staging system that incorporates symptoms at presentation and tumor size to predict severe surgical complications. Design, Setting, and Participants A retrospective cohort of patients at a single-center tertiary referral center from January 1, 1998, to October 13, 2020, was studied. Patients diagnosed with sporadic vestibular schwannoma surgically treated at Washington University in St Louis, Missouri, were included. Main Outcomes and Measures Severe surgical complications within 30 days of surgery as determined by the Clavien-Dindo classification system. Patients experiencing a complication of grade 3 or above were determined to have a severe complication. Results Of 185 patients evaluated, 40 (22%) had severe postoperative complications. Twenty of the 40 patients (50%) were women; mean (SD) age was 46 (13) years. Patients with severe complications were more likely to have large tumors (>2.5 cm in largest diameter), vestibular symptoms, and recent hearing loss at presentation. Using conjunctive consolidation, a 4-stage clinical severity staging system that incorporates clinical symptoms and tumor size at presentation was created to predict severe complications. The clinical severity staging system demonstrated an improvement in the ability to discriminate severe complications (C index, 0.754; 95% CI, 0.67-0.84) from a model of tumor size alone (C index, 0.706; 95% CI 0.62-0.79). Conclusions and Relevance This cohort study found that, among patients with vestibular schwannoma, symptoms present at initial evaluation, in addition to tumor size, served as predictors of severe postoperative complications. A new clinical severity staging system incorporating symptoms at presentation can be helpful for clinicians to identify patients at high risk for severe postoperative complications.
Collapse
|
17
|
Accuracy of an Automated Hearing Aid Fitting Using Real Ear Measures Embedded in a Manufacturer Fitting Software. J Am Acad Audiol 2021; 32:157-163. [PMID: 34062602 DOI: 10.1055/s-0041-1722947] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
BACKGROUND Hearing aid fitting guidelines recommend real ear measures (REM) to verify hearing aid performance. Unfortunately, approximately 70 to 80% of clinicians do not use REM, but instead download manufacturer first-fit. Studies report differences in performance between first-fit and programmed-fit with greatest differences in the higher frequencies. Recently, hearing aid and real ear analyzer (REA) manufacturers allow REA communication with hearing aid software feature to automatically program hearing aids to target. Little research is available reporting the accuracy of this feature. PURPOSE The aim of the study is to examine whether differences exist at 50, 65, and 80 dB SPL between two ReSound first-fit formulae (Audiogram+ and NAL-NL2) using ReSound AutoREM and Aurical NAL-NL2 RESEARCH DESIGN: The study design is of repeated measure type. STUDY SAMPLE The study sample includes 48 ears. DATA COLLECTION AND ANALYSIS For the two fitting formulae, AutoREM real ear insertion gain (REIG) was measured at 50, 65, and 80 dB SPL and compared with measures from Aurical NAL-NL2. RESULTS Mean AutoREM REIG for ReSound NAL-NL2 was 3 to 8 dB below Aurical NAL-NL2 for 50 dB SPL, within 1 to 3 dB for 65 dB SPL and 1 to 5 dB above for 80 dB SPL. Mean AutoREM REIG for Audiogram + was 1 to 12 dB below Aurical NAL-NL2 for 50 dB SPL, within 2 to 5 dB for 65 dB SPL and 1 to 7 dB above NAL-NL2 for 80 dB SPL. CONCLUSION Relative to the Aurical NAL-NL2, AutoREM REIG50 for Audiogram + and ReSound NAL-NL2 was lower. Relative to the Aurical NAL-NL2, AutoREM REIG65 for Audiogram + was higher at 1,000 Hz and lower at 4,000 to 6,000 Hz and for ReSound NAL-NL2 it was lower at 500 Hz and 4,000 Hz and higher at 3,000 Hz. Relative to the Aurical NAL-NL2, AutoREM REIG80 for Audiogram + was higher at 500 to 3,000 Hz and 6,000 Hz and ReSound NAL-NL2 was higher at 500 to 6,000 Hz. Because of wide intersubject variability clinicians should continue to use REM as a "check and balance" when using AutoREM.
Collapse
|
18
|
Hearing and Quality-of-Life Outcomes After Cochlear Implantation in Adult Hearing Aid Users 65 Years or Older: A Secondary Analysis of a Nonrandomized Clinical Trial. JAMA Otolaryngol Head Neck Surg 2021; 146:925-932. [PMID: 32857114 DOI: 10.1001/jamaoto.2020.1585] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Importance Hearing loss, especially moderate to severe forms, has the potential to negatively affect an individual's physical, social, emotional, and cognitive well-being. Moreover, having ineffective binaural hearing increases difficulty understanding speech in noise and leads to a greater degree of social isolation and loneliness and a reduced quality of life (QoL). Objective To explore the audiometric and holistic effects of cochlear implantation in a group of adults 65 years or older compared with an optimized bilateral hearing aid condition. Design, Setting, and Participants This ad hoc secondary analysis of a prospective, single-subject, repeated-measures nonrandomized clinical trial included 13 cochlear implantation centers across the United States. Participants 65 years or older with postlingual bilateral moderate-to-profound sensorineural hearing loss with aided Consonant-Vowel Nucleus-Consonant (CNC) word scores in quiet of 40% or less in the ear to undergo implantation and 50% or less in the contralateral ear were included in the analysis. Baseline QoL testing was performed after 1 month of optimized bilateral hearing aid use. Participants were enrolled from February 20, 2017, to May 3, 2018, and follow-up was completed December 21, 2018. Data were analyzed from March 25, 2019, to March 31, 2020. Interventions Unilateral implantation with a slim, modiolar cochlear implant device. Hearing aid use in the contralateral ear was required through the 6-month primary end-point interval. Main Outcomes and Measures The primary objective was to evaluate speech perception before and 6 months after activation of a new cochlear implant. Secondary objectives were QoL metrics in the everyday listening condition before and 6 months after implantation. Results Seventy participants (51 men [73%]) with a median age of 74 (range, 65-91) years were included in the analysis. No major adverse events occurred. Mixed-model analysis with estimated marginal means and 95% CIs compared preimplantation baseline performance with 6-month postimplantation performance. A clinically important improvement in CNC words was shown in the bimodal condition, with a mean difference of 37.2% (95% CI, 32.0%-42.4%), and in the unilateral (cochlear implant only) condition, with a mean difference of 44.1% (95% CI, 39.0%-49.2%). A clinically important improvement in noise (AzBio sentences signal-to-noise ratio of +10 dB) was also shown, with a mean difference of 21.6% (95% CI, 15.7%-27.5%) in the bimodal condition and 24.5% (95% CI, 18.3%-30.7%) in the unilateral condition. The Health Utilities Index Mark 3 multiple-attribute score improved by 0.186 (95% CI, 0.136-0.234); the Speech, Spatial, and Qualities of Hearing Scale total score improved by 2.58 (95% CI, 2.18-2.99); and a novel Device Use Questionnaire reported 94% of participants were satisfied with overall hearing in the everyday listening condition. Conclusions and Relevance This subgroup analysis of patients 65 years or older enrolled in a within-subject clinical trial of cochlear implantation demonstrated clinically meaningful audiometric and QoL benefit with an acceptable risk profile. These findings suggest that cochlear implantation in older adults may facilitate the concept of healthy aging. Trial Registration ClinicalTrials.gov Identifier: NCT03007472.
Collapse
|
19
|
Outcomes after mini-craniotomy middle fossa approach combined with mastoidectomy for lateral skull base defects. Am J Otolaryngol 2021; 42:102794. [PMID: 33130529 DOI: 10.1016/j.amjoto.2020.102794] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Accepted: 10/19/2020] [Indexed: 11/19/2022]
Abstract
PURPOSE Controversy exists regarding the ideal approach for repair of lateral skull base defects. Our goal is to report the outcomes following middle cranial fossa (MCF) mini-craniotomy combined with mastoidectomy for patients with superior semicircular canal dehiscence (SSCD), spontaneous cerebrospinal fluid (CSF) leak, and cholesteatoma. MATERIALS AND METHODS A retrospective database from chart review was formed consisting of 97 patients who met surgical criteria: SSCD, spontaneous CSF leak, and cholesteatoma. Mini-craniotomy MCF approach (<4 × 2 cm in size) combined with mastoidectomy was performed. All patients were admitted directly to the ICU postoperatively. Multiple factors were assessed, including need for revision surgery, duration of surgery, length of post-operative stay, and hospital readmission. RESULTS Average surgery time was 110 min with no intraoperative complications. The average length of hospitalization was 2 days with an average ICU stay of 1 day. There were no neurologic complications; however, there were 3 inpatient complications (3%) which included 1 patient (1%) that had wound breakdown and 2 patients (2%) that had severe post-operative vertigo. A total of 8 patients (8%) required revision surgery and these were primarily for SSCD. The 30-day readmission rate was 3%. CONCLUSION In the current series, all patients that underwent mini-craniotomy MCF surgery combined with mastoidectomy had minimal complications, short surgical time, limited hospital stay, low revision surgery rate and few hospital readmissions. This combined approach offers superior visualization of lateral skull base defects without the morbidity and risk typically associated with traditional, extensive MCF surgery.
Collapse
|
20
|
Assessment of Speech Understanding After Cochlear Implantation in Adult Hearing Aid Users: A Nonrandomized Controlled Trial. JAMA Otolaryngol Head Neck Surg 2020; 146:916-924. [PMID: 32857113 DOI: 10.1001/jamaoto.2020.1584] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Importance Cochlear implants were approved for use in adults in the 1980s, but use remains low owing to a lack of awareness regarding cochlear implantation candidacy criteria and expected outcomes. There have been limited, small series examining the safety and effectiveness of cochlear implantation in adult hearing aid (HA) users with and without mild cognitive impairment (MCI). Objective To investigate the safety and effectiveness of a single-ear cochlear implant in a group of optimized adult HA users with and without MCI across a variety of domains. Design, Setting, and Participants In this nonrandomized controlled trial, a multicenter, prospective, repeated-measures investigation was conducted at 13 US institutions. The setting was academic and community-based cochlear implant programs. Eligible participants were 100 adults (aged >18 years) with postlinguistic onset of bilateral moderate sloping to profound or worse sensorineural hearing loss (≤20 years' duration). Fluent English speakers underwent an optimized bilateral HA trial for at least 30 days. Individuals with aided Consonant-Vowel Nucleus-Consonant (CNC) word score in quiet of 40% or less correct in the ear to be implanted and 50% or less correct in the contralateral ear were offered cochlear implants. The first participant was enrolled on February 20, 2017, and the last participant was enrolled on May 3, 2018. The final follow-up was on December 21, 2018. Interventions Participants received the same cochlear implant system and contralateral HA. Main Outcomes and Measures The primary outcome measure was speech understanding in quiet (CNC word score) using both the cochlear implant and opposite ear HA. Secondary outcome measures included the following: adverse events; speech understanding in noise (AzBio signal-to-noise ratio of +10 db [+10 SNR]) Health Utilities Index Mark 3 (HUI3); Speech, Spatial, and Qualities of Hearing Questionnaire 49 (SSQ49); and Montreal Cognitive Assessment (MoCA). Results The median age at cochlear implantation of the 96 patients included in the trial was 71 years (range, 23-91 years), and 62 patients (65%) were male. Three serious adverse events requiring revision surgery occurred, and all resolved without sequelae. By 6 months after activation, the absolute marginal mean change in CNC word score and AzBio +10 SNR was 40.5% (95% CI, 35.9%-45.0%) and 24.1% (95% CI, 18.9%-29.4%), respectively. Ninety-one percent (87 of 96) of participants had a clinically important improvement (>15%) in the CNC word score in the implant ear. Mild cognitive impairment (MoCA total score ≤25) was observed in 48 of 81 study participants (59%) at baseline. Speech perception marginal mean improvements were similar between individuals with and without baseline MCI, with values of 40.9% (95% CI, 35.2%-46.6%) and 39.6% (95% CI, 31.8%-47.4%), respectively, for CNC word score and 27.5% (95% CI, 21.0%-33.9%) and 17.8% (95% CI, 9.0%-26.6%), respectively, for AzBio +10 SNR. Statistically significant and clinically important improvements in the HUI3 and SSQ49 were evident at 6 months. Conclusions and Relevance The findings of this nonrandomized controlled trial seem to indicate that cochlear implants are safe and effective in restoring speech understanding in both quiet and noise and improve quality of life in individuals with and without MCI. Trial Registration ClinicalTrials.gov Identifier: NCT03007472.
Collapse
|
21
|
Immediate and 1-Year Outcomes with a Slim Modiolar Cochlear Implant Electrode Array. Otolaryngol Head Neck Surg 2020; 162:731-736. [PMID: 32180504 DOI: 10.1177/0194599820907336] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
OBJECTIVE To explore the immediate and 1-year outcomes of patients who underwent implantation with the slim modiolar electrode (SME). STUDY DESIGN Consecutive case series with chart review. SETTING Tertiary referral academic center. SUBJECT AND METHODS Between May 2016 and August 2018, a total of 326 cochlear implantations (CIs) were performed. Intraoperative x-rays were performed in all cases to identify tip rollovers. Scalar location was identified for 76 CIs that had postoperative computed tomography reconstructions. Speech outcomes were measured at 3, 6, and 12 months with consonant-nucleus-consonant word and AzBio sentences in quiet and noise (+10-dB signal-to-noise ratio). Preservation of hearing was defined as maintaining a low-frequency pure tone average ≤80 dB at 250 and 500 Hz. RESULTS Among 326 CIs, 23 (7%) had tip rollovers. Postoperative reconstructions revealed 5 of 76 (6.6%) scalar translocations. A subset of 177 cases met criteria for evaluation of speech perception scores. The marginal mean differences between presurgery and 12 months for speech tests were as follows: consonant-nucleus-consonant, 43.7 (95% CI, 39.8-47.6); AzBio in quiet, 49.7 (95% CI, 44.9-54.4); and AzBio in noise, 29.9 (95% CI, 25.2-34.7). Sixty-one patients were identified with preservable hearing (low-frequency pure tone average ≤80 dB), and 12 of 61 (20%) preserved hearing at 1 year. CONCLUSION CI with SME provides reliable scala tympani insertion in a consistent perimodiolar position. An initially increased tip rollover rate improved with case volume and sheath design improvement. For long-term outcomes, speech performance was comparable to that of other cochlear implants. While hearing preservation for the SME may be better than prior perimodiolar electrodes, consistent outcomes are unlikely.
Collapse
|
22
|
Abstract
This cohort study uses data from state health care databases to determine the incidence and timing of infectious complications following cochlear implant surgery among patients in 5 US states between 2006 and 2016.
Collapse
|
23
|
What defines asymmetric sensorineural hearing loss? Laryngoscope 2018; 129:1023-1024. [DOI: 10.1002/lary.27504] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2018] [Revised: 06/26/2018] [Accepted: 07/18/2018] [Indexed: 11/11/2022]
|
24
|
Methotrexate-induced EBV-associated lymphoproliferative disorder presenting with an oropharyngeal mass. HUMAN PATHOLOGY: CASE REPORTS 2017. [DOI: 10.1016/j.ehpc.2016.11.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|
25
|
Complications and 30-day hospital readmission rates of patients undergoing tracheostomy: A prospective analysis. Laryngoscope 2017; 127:2746-2753. [DOI: 10.1002/lary.26668] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2017] [Revised: 03/23/2017] [Accepted: 04/05/2017] [Indexed: 11/10/2022]
|
26
|
Auditory responses to electric and infrared neural stimulation of the rat cochlear nucleus. Hear Res 2014; 310:69-75. [PMID: 24508368 DOI: 10.1016/j.heares.2014.01.008] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2013] [Revised: 01/11/2014] [Accepted: 01/20/2014] [Indexed: 10/25/2022]
Abstract
In an effort to improve the auditory brainstem implant, a prosthesis in which user outcomes are modest, we applied electric and infrared neural stimulation (INS) to the cochlear nucleus in a rat animal model. Electric stimulation evoked regions of neural activation in the inferior colliculus and short-latency, multipeaked auditory brainstem responses (ABRs). Pulsed INS, delivered to the surface of the cochlear nucleus via an optical fiber, evoked broad neural activation in the inferior colliculus. Strongest responses were recorded when the fiber was placed at lateral positions on the cochlear nucleus, close to the temporal bone. INS-evoked ABRs were multipeaked but longer in latency than those for electric stimulation; they resembled the responses to acoustic stimulation. After deafening, responses to electric stimulation persisted, whereas those to INS disappeared, consistent with a reported "optophonic" effect, a laser-induced acoustic artifact. Thus, for deaf individuals who use the auditory brainstem implant, INS alone did not appear promising as a new approach.
Collapse
|
27
|
Inner-ear measurements on temporal bone computed tomography, SNHL, and CI outcome: Is there a relationship? Cochlear Implants Int 2013; 12 Suppl 1:S54-7. [DOI: 10.1179/146701011x13001035753218] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2022]
|
28
|
3D CT Images of Congenital Anomalies. Otolaryngol Head Neck Surg 2011. [DOI: 10.1177/0194599811415823a219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Objective: Retrospectively determine the value of 3D reconstructions in addition to traditional 2D axial and coronal plane CT studies of pediatric cochlear implant candidates. Method: Pediatric cochlear implant candidates with preoperative CT scans were identified, and 3D reconstructions were created. Three readers were blinded to clinical data and interpreted the 2D axial and coronal scans. A separate set of interpretations was made with the addition of 3D reconstructions. Results: Between 1995 and 2009, 36 pediatric patients undergoing cochlear implantation with preoperative CT imaging were identified. Structures analyzed included the Vestibular Aqueduct, Cochlear Nerve Canal, Cochlea, and Vestibule. Visualization of congenital malformations was scored on a 3-point scale (1, visualized; 2, unsure; 3, not visualized). Wilcoxon signed rank test was used to compare the 2 interpretations. The addition of 3D reconstructions to 2D axial and coronal CT images is expected to improve visualization of malformations in cochlear implant candidates. This information is valuable for evaluation of cochlear implant candidates outside of the academic center setting and in resident training. Conclusion: Three-dimensional CT reconstructions are complimentary in identification of congenital malformations in cochlear implant candidates.
Collapse
|
29
|
Langzeitverlauf und Gesamtkosten der invasiven stationären Therapie der kri-tischen Ischämie der unteren Extremität - Vergleich von endovaskulärer und gefäßchirurgischer Therapie. ROFO-FORTSCHR RONTG 2011. [DOI: 10.1055/s-0031-1279156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
30
|
Secondary Systemic Immunosuppressants (SSI) After Myeloablative HLA Matched Related And Unrelated Bone Marrow Transplantation (BMT) Using High Dose Cyclophosphamide (HiCy) As Sole GVHD Prophylaxis. Biol Blood Marrow Transplant 2010. [DOI: 10.1016/j.bbmt.2009.12.031] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
31
|
P099 Efficacy and safety of colistin for the treatment of infections caused by multidrug-resistant isolates of Pseudomonas aeruginosa sensitive to colistin in patients with haematological malignancy. Leuk Res 2007. [DOI: 10.1016/s0145-2126(07)70447-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
32
|
O52 Biological and clinical features of adult biphenotypic acute leukemia: a case series. Blood Rev 2007. [DOI: 10.1016/s0268-960x(07)70068-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
33
|
[Ductus venosus agenesis]. ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX 2005; 98:542-8. [PMID: 15966606] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
OBJECTIVE Congenital absence of the ductus venosus is a rare anomaly in the fetus. The aim of our study was to evaluate the clinical and ultrasonographic features and outcome of the fetuses with ductus venosus agenesis. STUDY DESIGN We describe 12 cases in the period between 1992 and 2004. The umbilical vein drained either into the right atrium directly (2 cases) or by the coronary sinus (1 case), or in the inferior vena cava (5 cases), or in the azygos vein (1 case), or in the portal vein (3 cases). Our data where analyzed with the cases published in the literature. Two groups of anastomoses where defined on the basis of the hemodynamic consequences: the group of extrahepatic anastomoses (53 cases) and the group of intrahepatic anastomoses (22 cases). RESULTS In the group of extra hepatic anastomoses, cardiomegaly was the most common antenatal finding (39%), while in the intra hepatic group hydrops fetalis occurred most frequently (23%). Malformation rate was high in both groups (56% and 45%) and chromosomal anomalies where present in 9% of cases. CONCLUSION Careful assessment of the umbilical venous return and the ductus venosus should be a part of examination of every fetus with cardiomegaly, polyhydramnios, ascites or hydrops. In case of absence of the ductus venosus a referral scan, a fetal echocardiography and a karyotype should be performed.
Collapse
|