1
|
Over-the-counter products in tooth bleaching: A scoping review. J Dent 2024; 145:104989. [PMID: 38582435 DOI: 10.1016/j.jdent.2024.104989] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2024] [Revised: 04/01/2024] [Accepted: 04/03/2024] [Indexed: 04/08/2024] Open
Abstract
OBJECTIVE To map and summarize the current scientific evidence concerning the active ingredients, effectiveness, and adverse effects of over-the-counter (OTC) bleaching products. DATA AND SOURCE This study was conducted according to the PRISMA-ScR guidelines for scoping reviews and registered on the Open Science Framework platform. STUDY SELECTION Database searches were conducted in PubMed/MEDLINE, Embase, and Scopus up to January 2024. All in vitro, in situ, and clinical studies evaluating the effectiveness and adverse effects of OTC bleaching products were included. A descriptive analysis of the included studies was performed. RESULTS A total of 88 studies were included. Most of them were in vitro studies (n = 49), followed by randomized clinical trials (n = 28). The main OTC bleaching products identified were whitening or stain-removing toothpastes (n = 42), followed by whitening strips (n = 39). Most clinical studies indicate that whitening strips are effective in improving tooth color and providing whitening benefits. In contrast, the bleaching effectiveness of toothpastes, mouth rinses and whitening trays was mainly supported by in vitro studies. The main adverse effects associated with OTC bleaching agents were tooth sensitivity and gingival irritation. CONCLUSION A wide variety of OTC bleaching products is available for consumer self-administered use. Clinical studies have mainly confirmed the bleaching effectiveness of whitening strips, while the validation for toothpastes, mouth rinses and whitening trays has mainly relied on in vitro studies. Nevertheless, the use of OTC bleaching products may result in adverse effects, including tooth sensitivity, gingival irritation, and enamel surface changes. CLINICAL SIGNIFICANCE Some over-the-counter bleaching products may have whitening properties supported by clinical studies, particularly those containing hydrogen or carbamide peroxide. Nonetheless, clinicians must be aware of the potential risks associated with excessive self-administration of these products, which may result in adverse effects.
Collapse
|
2
|
Optical properties of dental zirconia, bovine dentin, and enamel-dentin structures. J ESTHET RESTOR DENT 2024; 36:511-519. [PMID: 38059691 DOI: 10.1111/jerd.13178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2023] [Revised: 10/25/2023] [Accepted: 11/20/2023] [Indexed: 12/08/2023]
Abstract
OBJECTIVE To evaluate the optical properties and the relative translucency parameter of Ceramill ZI White (3Y-TZP) and Ceramill Zolid FX White (5Y-PSZ) zirconia ceramic systems and compare them with those of the bovine dentin and enamel/dentin structures. MATERIALS AND METHODS 3Y-TZP and 5Y-PSZ zirconia ceramic systems were evaluated. A 0.5-mm-thick 3Y-TZP (3Y-NC.5), 0.5-mm-thick (5Y-NC.5), and 1.4-mm-thick (5Y-C.14) were used. A 0.5-mm-thick dentin specimens and 1.4-mm-thick enamel/dentin specimens (n = 5) were obtained from anterior bovine maxillary teeth. Scattering, absorption, transmittance, and albedo coefficient were calculated using Kubelka-Munk's model. Data were statistically analyzed using Kruskal-Wallis and Mann-Whitney tests (p < 0.001), and goodness-of-fit coefficient (GFC). Relative translucency parameter differences were evaluated using translucency thresholds. RESULTS Reflectance, scattering, absorption, and transmittance properties were wavelength dependent. Good matches (GFC ≥ 0.999) in spectral reflectance were observed between 0.5-mm-thick dentin and 1.4-mm-thick enamel/dentin, and 3Y-NC.5 and 5Y-NC.5. Scattering was the main optical extinction process during light interaction with zirconia and dental structures, as indicated by albedo coefficient. Translucency differences were acceptable only for 3Y-NC.5 and the dentin structure, and 5Y-C.14 and the enamel/dentin structure. CONCLUSIONS Optical properties of 3Y-TZP and 5Y-PSZ dental zirconia differed from each other and from bovine dental structures. Nevertheless, 3Y-TZP showed similar relative translucency parameter to bovine dentin. CLINICAL SIGNIFICANCE To achieve the best esthetic results in restorative dentistry, it is crucial for clinicians to know about the optical properties of 3Y-TZP and 5Y-PSZ and to be able to compare these properties with those of dental structures.
Collapse
|
3
|
Analysis of topography, flexural strength, and microstructure of a lithium-disilicate glass-ceramic after surface finishing. INT J PROSTHODONT 2023. [PMID: 37227860 DOI: 10.11607/ijp.8352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Glass-ceramic restorations often require adjustments using coarse diamond burs (D) which have the potential to introduce critical defects at the surface from which a crack can initiate and propagate until fracture. Surface finishing using fine and ultra-fine burs (F), polishing (P), or glazing (G) have the potential to reduce or eliminate these defects. PURPOSE This study investigated the influence of finishing, polishing, and glazing on the roughness, flexural strength, and microstructure of a lithium disilicate glass-ceramic (LD). MATERIALS AND METHODS LD CAD-CAM blocks were cut into 96 discs (1.2 mm x 12 mm). After crystallization, a layer of glaze was applied to the discs surface. The specimens were randomly divided into eight groups (n=12) for different surface treatments: G- glaze (control), GD, GDG, GDP, GF GFG, GFP, and GDFP. Mean roughness (Ra), mean square height (Rq) and maximum roughness (Rz) were measured. The biaxial flexural strength test was performed in a universal testing machine at 0.5 mm/min. Microstructural analysis was performed using X-ray diffraction patterns (XRD). Differences on the roughness obtained in distinct groups was analyzed by Kruskal-Wallis and Bonferroni tests (α = 0.05). The flexural strength tests were compared by one-way ANOVA. RESULTS Glazed groups (G, GDG and GFG) presented the lowest surface roughness, lower crystallinity, and higher flexural strength than the other groups. Although polishing and glaze presented similar surface roughness, polishing protocol decreased the flexural strength compared to the control group G. CONCLUSION clinically adjusted LD glass-ceramic restorations should be reglazed whenever possible to improve strength.
Collapse
|
4
|
Masking ability of resin composites: A scoping review. J ESTHET RESTOR DENT 2023; 35:333-344. [PMID: 36260930 DOI: 10.1111/jerd.12976] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Revised: 09/23/2022] [Accepted: 09/27/2022] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To map the existing evidence regarding the masking ability of resin composites. OVERVIEW The literature search was conducted electronically, based on the PRISMA Extension for Scoping Reviews-online protocol at https://osf.io/m2h67/ with no language or time restrictions. Two independent reviewers conducted the screening, and a third reviewer was consulted in case of disagreement. Studies that evaluated resin composite masking ability regardless of background, application technique, thickness, or number of layers were selected. The search found 2995 potentially eligible studies. After removal of duplicates (657), irrelevant articles (2323), 15 citations met the eligibility criteria based on title and abstract, and eight studies were included based on full text analysis (seven in vitro, and one case report). Acceptable masking ability is obtained by one layer of opaque shade resin composite or by the layering technique. A black background is masked with 1.0- to 2.0 mm-thick layers of opaque shade resin composites. Masking of the C4 background is achieved with one layer of 0.5- to 1.5 mm-thick opaque shade resin composite or by the layering technique using different combinations of enamel body and dentin shades with a final thickness of 1.5 mm. CONCLUSIONS Acceptable masking of C4 shade background is achieved with one layer of opaque shade composite at least 0.5 mm-thick or by different combinations of the layering technique, with a final thickness of 1.5 mm. Acceptable masking of the black background of the oral cavity is achieved with a resin composite of at least 1.0 mm opaque shade. CLINICAL SIGNIFICANCE The thickness of the resin composite layer required to achieve adequate masking is variable and depends on the translucency/opacity of the tested resin composites and the background shade.
Collapse
|
5
|
Comparison of visual shade matching and photographic shade analysis. J ESTHET RESTOR DENT 2022; 34:374-382. [PMID: 35128799 DOI: 10.1111/jerd.12883] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2021] [Revised: 01/17/2022] [Accepted: 01/21/2022] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To compare the performance of a standardized photographic shade analysis (PSA) and visual shade matching (VSM) using two color difference formulas. MATERIALS AND METHODS Fifty observers (35 undergraduate and 15 graduate students) evaluated the color of two upper left central incisors (LT-light tooth, and DT-dark tooth). VSM was performed using the VITA 3D Master (3D) shade guide in a controlled clinical environment. For PSA, a cross-polarized filter and a gray card (Whibal) were used to standardize the photographs taken (target teeth and shade tabs from 3D). From the pictures obtained, the CIELAB coordinates, and color differences ( Δ E ab * and ΔE00 ) were obtained. The shade tabs selected by two experienced researchers were conducted as part of the pilot study, and finally used as a standard for the analysis. Data were analyzed using descriptive statistics and the chi-square test (p ≤ 0.05). RESULTS Shade tabs selections of VSM and PSA agreed only for LT. The best "Match" selected by the researchers agreed with data from PSA using ΔE00 . PSA using ΔE00 showed higher total percentages of "Match" and higher percentage of agreement among observers. A relationship was found for LT performing the PSA (p < 0.05). CONCLUSIONS The performance of the PSA was better than the VSM, but only when the CIEDE2000 color difference formula was used. Therefore, the color difference formulas influenced on the performance of PSA. Finally, the PSA improved the precision of the VSM. CLINICAL SIGNIFICANCE To use a standardized PSA to improve the VSM and shade communication in clinical esthetic dentistry.
Collapse
|
6
|
Color Change of Resin-based Composites After In Vitro Bleaching Protocols: A Systematic Review and Meta-analysis. Oper Dent 2022; 47:149-162. [PMID: 35029690 DOI: 10.2341/20-234-lit] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/26/2021] [Indexed: 11/23/2022]
Abstract
OBJECTIVES To systematically review the literature on color stability of resin-based composites (RBC) after in vitro bleaching protocols and to assess the influence of bleaching protocols by meta-regression analysis on RBC color stability, and the association with clinical and experimental characteristics. METHODS The electronic search was conducted in MEDLINE/PubMed, Scopus, and Web of Science databases and included English language studies that evaluated and reported color differences (CIELAB values) of RBC after in vitro bleaching procedures using hydrogen peroxide and/or carbamide peroxide. RESULTS Database search for color change of RBC after bleaching retrieved 1335 eligible papers after removing duplicates. After initial screening, 66 articles were assessed for full-text reading with final inclusion of 23 published papers. A meta-regression analysis showed that storage time (p≤0.01), color measuring device (p≤0.01), and background color (p≤0.01) had influenced on color changes of RBC. The bleaching protocol (bleaching agent and time of application) did not influence on color changes of RBC (p>0.01). CONCLUSIONS There is evidence that RBC change color after bleaching, but the change is not clinically significant.
Collapse
|
7
|
Applications of artificial intelligence in dentistry: A comprehensive review. J ESTHET RESTOR DENT 2021; 34:259-280. [PMID: 34842324 DOI: 10.1111/jerd.12844] [Citation(s) in RCA: 44] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 09/30/2021] [Accepted: 11/09/2021] [Indexed: 12/25/2022]
Abstract
OBJECTIVE To perform a comprehensive review of the use of artificial intelligence (AI) and machine learning (ML) in dentistry, providing the community with a broad insight on the different advances that these technologies and tools have produced, paying special attention to the area of esthetic dentistry and color research. MATERIALS AND METHODS The comprehensive review was conducted in MEDLINE/PubMed, Web of Science, and Scopus databases, for papers published in English language in the last 20 years. RESULTS Out of 3871 eligible papers, 120 were included for final appraisal. Study methodologies included deep learning (DL; n = 76), fuzzy logic (FL; n = 12), and other ML techniques (n = 32), which were mainly applied to disease identification, image segmentation, image correction, and biomimetic color analysis and modeling. CONCLUSIONS The insight provided by the present work has reported outstanding results in the design of high-performance decision support systems for the aforementioned areas. The future of digital dentistry goes through the design of integrated approaches providing personalized treatments to patients. In addition, esthetic dentistry can benefit from those advances by developing models allowing a complete characterization of tooth color, enhancing the accuracy of dental restorations. CLINICAL SIGNIFICANCE The use of AI and ML has an increasing impact on the dental profession and is complementing the development of digital technologies and tools, with a wide application in treatment planning and esthetic dentistry procedures.
Collapse
|
8
|
Experimental methodologies to evaluate the masking ability of dental materials: A systematic review. J ESTHET RESTOR DENT 2021; 33:1118-1131. [PMID: 34085377 DOI: 10.1111/jerd.12791] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 04/19/2021] [Accepted: 05/25/2021] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To conduct a systematic review on the masking ability of discolored substrates, analyzing the capacity and quality of the response produced by the different methodologies and techniques applied to overcome this clinical challenge. MATERIALS AND METHODS The study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. The electronic search was conducted in MEDLINE/PubMed, Scopus and Web of Science databases, without date restriction. In vitro studies, written in English, applying different methodologies to evaluate masking ability were included. The variables of interest were: type, color and thickness of the restorative and/or cement material; use of pigments in the restorative material and/or cement; color of the substrate; and background color used for the evaluations. RESULTS Database search retrieved 307 eligible papers with a final inclusion of 47 published papers. Approximately 98% of the studies used ΔE, 36% used TP, and only 6% used CR to evaluate the masking ability of restorative materials. CONCLUSIONS The most appropriate methodology to evaluate the masking ability is using color difference equations (ΔE) associated with the perceptibility and acceptability thresholds. CLINICAL SIGNIFICANCE As different methodologies have been used to evaluate the masking ability of esthetic restorative materials on colored substrates, there is an urgent need to reach a consensus and propose a method, which is suggested by the present systematic review.
Collapse
|
9
|
Influence of background color on color perception in dentistry. J Dent 2021; 108:103640. [PMID: 33757865 DOI: 10.1016/j.jdent.2021.103640] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Revised: 03/15/2021] [Accepted: 03/18/2021] [Indexed: 11/15/2022] Open
Abstract
OBJECTIVE To evaluate the influence of neutral color backgrounds on the perception of color differences in dentistry. METHODS A software was developed for this study that calculated the perceptibility (PT) and acceptability (AT) thresholds of color differences between a pair of computer-simulated incisor samples (n = 60 pairs) over three neutral color (white, gray and black) backgrounds. CIELAB and CIEDE2000 color difference formulas were used. Five groups of volunteer observers (N = 100) participated in the psychophysical experiment (n = 20): Dentists; Dental students; Dental auxiliaries; Dental technicians; and Laypersons. The psychophysical experiment was performed in a dark environment on a calibrated high-resolution screen. To determine PT and AT values, the 60 pairs of samples were randomly presented to each observer over the different backgrounds. The data were adjusted (TSK Fuzzy) and analyzed statistically using Student t-test and ANOVA (α = 0.05). RESULTS Regardless of the metric and the background used, the PT values showed no difference among different observers (p > 0.05). Dentists showed the lowest PT values. Dental technicians showed the lowest AT (p ≤ 0.05) and similar values for the three backgrounds (p > 0.05), regardless of the metric used. The other groups of observers showed the lowest and the highest AT values when using black and white backgrounds, respectively (p ≤ 0.05). CONCLUSIONS The lowest AT values using a black background indicates that the use of this background allows for the evaluation of slight color differences, and should be used for challenging color differences in esthetic dentistry. This study showed the influence of the observer experience on color evaluation in dentistry. CLINICAL SIGNIFICANCE There was no influence of the background color on the perceptibility threshold. However, dentists and dental technicians showed greater ability to perceive slight color differences compared to other groups of observers.
Collapse
|
10
|
Does background color influence visual thresholds? J Dent 2020; 102:103475. [DOI: 10.1016/j.jdent.2020.103475] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Revised: 09/09/2020] [Accepted: 09/11/2020] [Indexed: 10/23/2022] Open
|
11
|
Efficacy of color discrimination tests used in dentistry. J ESTHET RESTOR DENT 2020; 33:865-873. [DOI: 10.1111/jerd.12673] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2020] [Revised: 09/09/2020] [Accepted: 10/12/2020] [Indexed: 11/30/2022]
|
12
|
Effect of substrate and cement on the final color of zirconia-based all-ceramic crowns. J ESTHET RESTOR DENT 2020; 33:891-898. [PMID: 32757249 DOI: 10.1111/jerd.12632] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2019] [Revised: 06/07/2020] [Accepted: 07/08/2020] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To evaluate the influence of the substrate and the cement on the final color of ceramic crowns. METHODS Prosthetic crowns (framework + porcelain) were fabricated using two all-ceramic systems (YZ, 3 mol% yttria-stabilized tetragonal zirconia; IZ, alumina-based zirconia-reinforced glass-infiltrated ceramic) and a metal-ceramic system (MC; n = 8). Metal (M) and resin (R) were used as substrate abutments. For R substrate, crowns were evaluated as seated (R) and after cementation (R-C). CIELAB color coordinates were obtained using a dental spectrophotometer with D65 light illumination. CIELAB, CIEDE2000 (1:1:1) and CIEDE2000 (2:1:1) color difference metrics were used. Data were analyzed using 95% confidence intervals and compared to perceptibility (PT) and acceptability (AT) thresholds. RESULTS The ∆ E ab * , ∆E00 (1 : 1 : 1), and ∆E00 (2 : 1 : 1) values of the restorative systems evaluated using different substrates (M.R) were similar to the AT values of each metric. When non-cemented and cemented crowns were evaluated (R.R-C), MC had color difference values at PT and below AT; while YZ and IZ showed similar values to AT, for ∆ E ab * and ∆E00 (1 : 1 : 1) metrics. CONCLUSION The substrate and cement affected the final color of zirconia-based all-ceramic crowns, but the color differences corresponded to an acceptable match. CLINICAL SIGNIFICANCE As both substrate and cement influence the final color of multi-layered ceramic prosthesis, dentists and dental technicians should understand the optical properties of dental ceramics to reproduce the natural appearance of dental structures and maximize the chance for excellent color matches.
Collapse
|
13
|
Intraoral repair of a chipped porcelain-zirconia restoration. J ESTHET RESTOR DENT 2020; 32:444-450. [PMID: 32442351 DOI: 10.1111/jerd.12592] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2019] [Revised: 04/09/2020] [Accepted: 04/20/2020] [Indexed: 01/18/2023]
Abstract
OBJECTIVE Ceramic fracture is an undesirable outcome of the rehabilitation with fixed partial dentures (FPD), mainly because it may involve additional cost and clinical time for intraoral repair or replacement of the restoration. This clinical report describes a 5 years survival intraoral repair of a chipped porcelain veneered zirconia framework restoration using a resin-based composite. CLINICAL CONSIDERATIONS A FPD of porcelain veneered zirconia was made. After 18 months, the FPD presented a porcelain chip (porcelain fracture without exposure to the zirconia structure) on the buccal side of the pontic. An epoxy resin replica of the fractured surface was obtained and was examined under scanning electron microscopy. Fracture origin was found at the cervical area of the pontic. Intraoral repair by bonding the chipped fragment back in place was performed. After 15 days, the porcelain fragment debonded without patient knowledge and the fragment was lost. Then, intraoral repair using composite resin to restore the fractured area was performed and is still in function to date. CONCLUSIONS Based on the 5-years survival of the performed intraoral repair, the composite resin reconstruction technique has shown to be an adequate alternative treatment for fractured FPD. CLINICAL SIGNIFICANCE A resin composite repair of the fracture site can be performed in one clinical session, using much less time and cost than for the replacement of FPD. This clinical case survived 5 years to date.
Collapse
|
14
|
Influence of Bleaching and Aging Procedures on Color and Whiteness of Dental Composites. Oper Dent 2019; 44:648-658. [DOI: 10.2341/18-209-l] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
SUMMARY
Bleaching can cause perceptible color changes on resin-based composite (RBC) restorations that may not be stable with aging. The objective of this study was to evaluate color stability and whiteness variations of RBCs after bleaching and aging procedures. Discs (10 mm in diameter and 1 mm thick) of shades A2 and A3 were fabricated from two RBCs (Filtek Z250 and Filtek Z350 XT) and divided into three subgroups (for each composite and shade) (n=5) as follows: control (no bleaching), at-home bleaching, and in-office bleaching. All specimens underwent an accelerated artificial aging up to 450 KJ/m2 and 900 KJ/m2 in an aging chamber (Suntest XXL+). A spectroradiometer (SpectraScan PR-670) was used to obtain CIE L*a*b* coordinates. CIEDE2000 color difference (ΔE00) and whiteness index for dentistry (WID) were used to evaluate color stability. Color and whiteness differences data were analyzed considering the 50:50% visual color difference thresholds (perceptibility [PT] and acceptability [AT]) and 50:50% whiteness thresholds (whiteness perceptibility [WPT] and whiteness acceptability [WAT]). Analysis of variance and Tukey tests (α=0.05) were used to statistically analyze the data. After bleaching, all specimens showed ΔE00 and ΔWID values below their corresponding acceptability thresholds (AT and WAT, respectively). After aging, L* and WID values decreased while b* values increased (p≤0.05), resulting in ΔE00 and ΔWID values above AT and WAT, respectively. Color changes after bleaching RBCs were clinically acceptable, while aging provoked clinically perceptible color changes.
Collapse
|
15
|
Optical and colorimetric evaluation of a multi-color polymer-infiltrated ceramic-network material. Dent Mater 2019; 35:e131-e139. [PMID: 31000216 DOI: 10.1016/j.dental.2019.03.010] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2018] [Revised: 02/25/2019] [Accepted: 03/26/2019] [Indexed: 11/15/2022]
Abstract
OBJECTIVE To evaluate color, translucency parameter and optical properties (scattering (S), absorption (K) and transmittance (T)) of a multi-color polymer-infiltrated ceramic-network (PICN) material. METHODS Samples of shades 1M1-HT, 1M2-HT, 2M2-HT, 3M2-HT, and 4M2-HT from VITA ENAMIC® multiColor (E-MC) High Translucent were fabricated (n = 3). CAD-CAM blocks were cut and polished to 1.00 ± 0.01 mm of thickness. Diffuse reflectance and color coordinates were measured against white and black backgrounds, using a calibrated spectroradiometer, CIE D65 illuminant and the CIE 45°/0° geometry. Color and translucency differences were evaluated using 50:50% perceptibility (PT and TPT) and 50:50% acceptability (AT and TAT) thresholds. S and K coefficients and T were calculated using Kubelka-Munk's equations. Data was statistically analyzed using Kruskal-Wallis, Mann-Whitney tests, and VAF coefficient. RESULT Mean C* and b* values increased from incisal to cervical layers with statistically significant differences (p < 0.05). In general, ΔE00 between sequential layers were above PT for all shades. In addition, translucency parameter (TP) increased from cervical to incisal and ΔTP00 values were greater than TPT00 and lower than TAT00 between all sequential layers. Layers from all shades showed similar spectral behavior for S (97.4% ≤ VAF), K (85.0% ≤ VAF) coefficients and T (95.3% ≤ VAF). However, these values presented significant differences (p < 0.05) from cervical to incisal layers. SIGNIFICANCE The gradient in color and translucency of this novel CAD-CAM multi-color PICN material can assist dental technicians and dentists to reach greater esthetics than the pre-existing CAD-CAM monolithicmaterials.
Collapse
|
16
|
Abstract
Background:
The final goal of color measurement or shade specification in dentistry is
the reproduction by prosthetic materials of all important appearance characteristics of natural oral
structures. The application of color science in dentistry is an objective way to measure and evaluate
such structures and dental materials in clinical practice and dental research.
Methods:
Literature on color science was reviewed to present new metrics to evaluate color differences
of dental materials and dental structures. Visual acceptability and perceptibility values of color
differences are reviewed and new whiteness indexes to describe whiteness in dentistry are presented.
Results:
In the last decade, the CIELAB 50:50% perceptibility and acceptability thresholds were set
to 1.2 and 2.7, respectively, and the CIEDE2000 50:50% perceptibility and acceptability thresholds
were set to 0.8 and 1.8. The CIEDE2000 color-difference formula became increasingly popular in
dentistry. Developments in color science have led to the description of tooth whiteness and changes
in tooth whiteness based on whiteness indexes, with the most relevant being the WID whiteness index,
which is a customized index based in CIELAB color space.
Conclusion:
The application of color science in dentistry has allowed the precise description of
tooth color and whiteness. The revised and new CIEDE2000 color-difference formula is expected to
fully replace the outdated CIELAB formula in almost all dental applications. Recent psychophysical
studies have reported values of visual thresholds and new whiteness indexes, which can serve as
quality control tools to guide the selection of esthetic dental materials, evaluate clinical performance,
and interpret visual and instrumental findings in clinical dentistry, dental research, and subsequent
standardization.
Collapse
|
17
|
Whiteness difference thresholds in dentistry. Dent Mater 2018; 35:292-297. [PMID: 30527588 DOI: 10.1016/j.dental.2018.11.022] [Citation(s) in RCA: 82] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2018] [Revised: 11/12/2018] [Accepted: 11/15/2018] [Indexed: 10/27/2022]
Abstract
OBJECTIVE To determine the visual whiteness thresholds for esthetic dentistry using the whiteness index for dentistry based on CIELAB color space (WID). METHODS A total of 60 observers (Dentists and Laypersons; n=30) from three research sites participated in the study. A psychophysical experiment based on visual assessments of simulated images of teeth on a calibrated display was performed. Images of simulated upper central incisors (SUCI) were consecutively displayed in pairs (60) and the whiteness of each SUCI pair was compared. WID was used to calculate the visual thresholds (WPT- perceptibility threshold; and WAT- acceptability threshold) with 95% confidence intervals (CI) and a Takagi-Sugeno-Kang (TSK) Fuzzy Approximation model was used as fitting procedure. Data was statistical analyzed using paired t-test (α=0.05). RESULTS WPT and WAT were 0.72 (CI: 0.0-2.69; r2=0.52) and 2.62 (CI: 0.2-7+; r2=0.57) WID units, respectively. Significant differences (p<0.05) were found between WPT and WAT, and between dentist (WPT=0.46WID units; WAT=2.20 WID units) and layperson (WPT=0.94 WID units; WAT=2.95 WID units). SIGNIFICANCE The visual whiteness difference thresholds determined with WID index can serve as reference values for research and manufacturing of dental materials, and for clinical practice situations such as assessing the effectiveness of bleaching treatments.
Collapse
|
18
|
Effect of hydrogen peroxide on color and whiteness of resin‐based composites. J ESTHET RESTOR DENT 2018; 31:132-139. [DOI: 10.1111/jerd.12443] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2018] [Revised: 10/24/2018] [Accepted: 11/04/2018] [Indexed: 11/30/2022]
|
19
|
How heating and surface finishing affect the crystalline and mechanical properties of CAD–CAM dental lithium disilicate glass ceramic. Acta Crystallogr A Found Adv 2018. [DOI: 10.1107/s2053273318091167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/03/2023] Open
|
20
|
Influence of composite type and light irradiance on color stability after immersion in different beverages. J ESTHET RESTOR DENT 2018; 30:390-396. [DOI: 10.1111/jerd.12383] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
21
|
|
22
|
Lightness, chroma and hue differences on visual shade matching. Dent Mater 2016; 32:1362-1373. [DOI: 10.1016/j.dental.2016.08.218] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2016] [Revised: 06/06/2016] [Accepted: 08/16/2016] [Indexed: 11/16/2022]
|
23
|
Relevant optical properties for direct restorative materials. Dent Mater 2016; 32:e105-12. [DOI: 10.1016/j.dental.2016.02.008] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2015] [Accepted: 02/26/2016] [Indexed: 10/22/2022]
|
24
|
Colour parameters and shade correspondence of CAD–CAM ceramic systems. J Dent 2015; 43:726-34. [DOI: 10.1016/j.jdent.2015.02.015] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2014] [Revised: 01/21/2015] [Accepted: 02/26/2015] [Indexed: 10/23/2022] Open
|
25
|
HOW DO I MANAGE A PATIENT WITH A FRACTURED PORCELAIN VENEER? JOURNAL (CANADIAN DENTAL ASSOCIATION) 2015; 81:f25. [PMID: 26679338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
|
26
|
Optical behavior of dental zirconia and dentin analyzed by Kubelka-Munk theory. Dent Mater 2014; 31:60-7. [PMID: 25499249 DOI: 10.1016/j.dental.2014.11.012] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2014] [Revised: 11/13/2014] [Accepted: 11/14/2014] [Indexed: 12/30/2022]
Abstract
OBJECTIVES To use the Kubelka-Munk theory to evaluate the scattering (S), absorption (K) and transmittance (T) of non-colored and colored dental zirconia systems and human (HD) and bovine (BD) dentins. METHODS Two zirconia systems were used: ZC- ZirCAD (Ivoclar Vivadent) and LV-LAVA (3M ESPE). Specimens from each ceramic system were divided into 3 groups (n=5): ZC1 and LV1 (non-colored); ZC2 and LV2 colored to shade A1, and ZC3 and LV3 colored to shade A3. Five human and bovine anterior teeth were flattened and polished through 1200 grit SiC paper to expose the superficial buccal dentin. All samples were prepared to a final thickness of 0.5 mm. Diffuse reflectance was measured against white and black backgrounds, using a spectroradiometer in a viewing booth with D65 illuminant and d/0° geometry. S and K coefficients and T were calculated using Kubelka-Munk's equations. Data was statistically analyzed using Kruskal-Wallis, Mann-Whitney tests, and VAF coefficient. RESULTS Spectral distributions of S, K and T were wavelength dependent. The spectral behavior of S and T was similar to HD (VAF≥96.80), even though they were statistically different (p≤0.05). The spectral behavior of K was also similar to HD, except for LV1 (VAF=38.62), yet all ceramics were statistically different from HD (p≤0.05). HD and BD showed similar values of S and T (p>0.05). SIGNIFICANCE The dental professional should consider the optical behavior differences between the zirconia systems evaluated and the human dentin to achieve optimal esthetics in restorative dentistry.
Collapse
|
27
|
|
28
|
Optical properties of CAD–CAM ceramic systems. J Dent 2014; 42:1202-9. [DOI: 10.1016/j.jdent.2014.07.005] [Citation(s) in RCA: 121] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2014] [Revised: 07/04/2014] [Accepted: 07/07/2014] [Indexed: 11/26/2022] Open
|
29
|
Color and translucency of zirconia ceramics, human dentine and bovine dentine. J Dent 2012; 40 Suppl 2:e34-40. [DOI: 10.1016/j.jdent.2012.08.018] [Citation(s) in RCA: 73] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2012] [Revised: 08/22/2012] [Accepted: 08/25/2012] [Indexed: 10/27/2022] Open
|
30
|
Abstract
This study deals with the influence of surface roughness on the color of resin composites. Ten resin composites (microfilled, hybrid, and microhybrid) were each polished with 500-grit, 1200-grit, 2000-grit, and 4000-grit SiC papers. The roughness parameter (R(a)) was measured using a Plμ confocal microscope, and field-emission scanning electron microscope (Fe-SEM) images were used to investigate filler morphology. Color was measured using a spectroradiometer and a D65 standard illuminant (geometry diffuse/0° specular component excluded (SCE) mode). Surface roughness decreased with grit number and was not influenced by filler size or size distribution. A significant influence of R(a) on lightness (L*) was found. Lightness increased with decreases in roughness, except for specimens that underwent polishing procedure 4 (PP4; 500-grit, 1200-grit, 2000-grit, and 4000-grit SiC papers consecutively). Generally, it was found that surface roughness influenced the color of resin composites. The composites that underwent PP1 (500-grit SiC paper) exhibited significant differences in chroma (C*), hue (h°), and lightness (L*) compared to composites that underwent PP3 (500-grit, 1200-grit, and 2000-grit SiC papers consecutively) and PP4. Color difference (∆E*) between the polishing procedures was within acceptability thresholds in dentistry.
Collapse
|
31
|
Abstract
OBJECTIVE This systematic review presents the loading protocols applied when using implants and/or screws in orthodontic treatments. MATERIALS AND METHODS Clinical trials which assessed the use of implants and/or screws for orthodontic anchorage and studies involving treatment on syndromic patients, surgery, other simultaneous treatments, or appliances (ie mini-plates) were considered. Electronic databases (Medline, Medline In-Process & Other Non-Indexed Citations, Lilacs, Pubmed, Embase, Web of Science, and All Evidence Based Medicine Reviews) were searched with the help of a senior Health Sciences librarian. Abstracts which appeared to fulfill the selection criteria were selected by consensus. The original articles were then retrieved and evaluated with a methodological checklist. References were also hand searched for possible missing articles. RESULTS Eleven articles fulfilled the selection criteria established. Five studies involved the use of implants while six involved the use of screws for orthodontic purposes. An individual methodological analysis for each article was made. CONCLUSIONS Loading protocols for implants involve a minimum waiting period of 2 months before applying orthodontic forces while loading protocols for screws involve immediate loading or a waiting period of 2 weeks to apply forces. Success rates for implants were on average higher than for screws.
Collapse
|