1
|
Investigation of interactions between biological thiols and gold nanoparticles by capillary electrophoresis with laser-induced fluorescence. Electrophoresis 2024. [PMID: 38191956 DOI: 10.1002/elps.202300248] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Revised: 12/19/2023] [Accepted: 01/01/2024] [Indexed: 01/10/2024]
Abstract
Biological thiols spontaneously form a stable Au-S dative bond with gold nanoparticles (AuNP) that might be used for their selective extraction and enrichment in biological samples. In this work, interactions of selected biological thiols (glutathione, cysteine, homocysteine [Hcys], cysteamine [CA], and N-acetylcysteine) with AuNP stabilized by different capping agents (citrate, Tween 20, Brij 35, CTAB, SDS) were investigated by UV-Vis spectroscopy and capillary electrophoresis with laser-induced fluorescence. Spectrophotometric measurements showed aggregation of Hcys and CA with AuNP. In contrast, it was confirmed by CE-LIF that biological thiols were adsorbed to all types of AuNP. Citrate-capped AuNP were selected for AuNP-based extraction of biological thiols from exhaled breath condensate (EBC). Dithiothreitol was utilized for desorption of biological thiols from the AuNP surface, which was followed by derivatization with eosin-5-maleimide and CE-LIF analysis. AuNP-based extraction increased the sensitivity of CE-LIF analysis; however, further optimization of methodology is necessary for accurate quantification of biological thiols in EBC.
Collapse
|
2
|
An open source 3D printed autosampler for capillary electrophoresis. Anal Chim Acta 2023; 1279:341832. [PMID: 37827625 DOI: 10.1016/j.aca.2023.341832] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Revised: 09/15/2023] [Accepted: 09/17/2023] [Indexed: 10/14/2023]
Abstract
BACKGROUND In-house built capillary electrophoresis (CE) systems represent a significant share of laboratory instrumentation. In most of these instruments, sample injection is effected manually with low to moderate precision and requires skilled operators. Although few automated samplers have been previously developed, typically only one sample at a time can be injected. If a series of samples is to be analyzed, manual intervention is required. In the present work, we developed and constructed a fully automated, open source, CE autosampler, able to handle up to 14 different samples that can be used as a modular component of any in-house built CE instrument. RESULTS An inexpensive, 3D printed, open source, autosampler for CE was developed. The autosampler consists of two parts: an injection unit with carousel containing sample and electrolyte vials and a flushing unit, containing a miniature pressure/vacuum pump. The autosampler is operated by an Arduino Mega microcontroller and an Arduino code written in the laboratory. The injection sequence is entered through a keypad and LCD display by the user. The instrument can operate autonomously for extended periods of time. It was used for fully automated analysis and/or calibration of up to 14 samples with excellent injection repeatability reaching less than 2.7% RSD for peak areas. The sampler performance was tested with two independently built CE instruments, a CE system with contactless conductivity detection (C4D) and a CE system with laser induced fluorescence (LIF) detector. SIGNIFICANCE AND NOVELTY A novel, 3D printed, Arduino-based autosampler for CE was developed. The autosampler allows autonomous hydrodynamic injection of up to 14 different samples with fully programmable injection sequence, including capillary flushing and high voltage and data acquisition control. It provides the missing instrumental sampling setup for laboratory made CE instruments. It can be simply constructed based on the open-source blueprints in any laboratory and be a useful and time-saving add-on to any modular CE instrument.
Collapse
|
3
|
Use of metal nanoparticles for preconcentration and analysis of biological thiols. Electrophoresis 2023; 44:135-157. [PMID: 35892259 DOI: 10.1002/elps.202200142] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Revised: 07/11/2022] [Accepted: 07/19/2022] [Indexed: 02/01/2023]
Abstract
Metal nanoparticles (NPs) exhibit several unique physicochemical properties, including redox activity, surface plasmon resonance, ability to quench fluorescence, biocompatibility, or a high surface-to-volume ratio. They are being increasingly used in analysis and preconcentration of thiol containing compounds, because they are able to spontaneously form a stable Au/Ag/Cu-S dative bond. They thus find wide application in environmental and particularly in medical science, especially in the analysis of biological thiols, the endogenous compounds that play a significant role in many biological systems. In this review article, we provide an overview of various types of NPs that have been applied in analysis and preconcentration of biological thiols, mainly in human biological fluids. We first discuss shortly the types of NPs and their synthesis, properties, and their ability to interact with thiol compounds. Then we outline the sample preconcentration and analysis methods that were used for this purpose with special emphasis on optical, electrochemical, and separation techniques.
Collapse
|
4
|
Quantification and identification of bile acids in saliva by liquid chromatography-mass spectrometry: Possible non-invasive diagnostics of Barret´s esophagus? J Chromatogr A 2022; 1676:463287. [DOI: 10.1016/j.chroma.2022.463287] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2022] [Revised: 06/24/2022] [Accepted: 06/25/2022] [Indexed: 10/17/2022]
|
5
|
High-resolution Arduino-based data acquisition devices for microscale separation systems. Anal Chim Acta 2021; 1153:338294. [PMID: 33714439 DOI: 10.1016/j.aca.2021.338294] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Revised: 01/29/2021] [Accepted: 02/01/2021] [Indexed: 12/11/2022]
Abstract
In this work, we have designed, constructed, and evaluated simple, inexpensive open-source data acquisition systems based on various analog-to-digital converter modules (ADS 1115, MCP 3424, LTC 2400, with resolution from 16 to 24-bit) and a miniature Arduino Nano ™ microcontroller. The constructed data acquisition systems provide excellent performance and are comparable to a commercial, 24-bit device. We provide full schematics and corresponding source codes so that analytical chemists can easily construct any of the developed systems without extensive electronic or programming knowledge. The 24-bit LTC 2400 based device provided the best and comparable performance to a commercial, high-end 24-bit sigma to delta converter (ORCA 2800) at a fraction of cost (less than 50 USD compared to 870 USD for the commercial counterpart). The excellent performance was verified using a capillary electrophoresis system with contactless conductivity detection and separation of inorganic ions in clinical skin wipe and tap water samples.
Collapse
|
6
|
Analysis of bile acids in human biological samples by microcolumn separation techniques: A review. Electrophoresis 2020; 42:68-85. [PMID: 32645223 DOI: 10.1002/elps.202000139] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2020] [Revised: 07/03/2020] [Accepted: 07/04/2020] [Indexed: 12/13/2022]
Abstract
Bile acids are a group of compounds essential for lipid digestion and absorption with a steroid skeleton and a carboxylate side chain usually conjugated to glycine or taurine. Bile acids are regulatory molecules for a number of metabolic processes and can be used as biomarkers of various disorders. Since the middle of the twentieth century, the detection of bile acids has evolved from simple qualitative analysis to accurate quantification in complicated mixtures. Advanced methods are required to characterize and quantify individual bile acids in these mixtures. This article overviews the literature from the last two decades (2000-2020) and focuses on bile acid analysis in various human biological samples. The methods for sample preparation, including the sample treatment of conventional (blood plasma, blood serum, and urine) and unconventional samples (bile, saliva, duodenal/gastric juice, feces, etc.) are shortly discussed. Eventually, the focus is on novel analytical approaches and methods for each particular biological sample, providing an overview of the microcolumn separation techniques, such as high-performance liquid chromatography, gas chromatography, and capillary electrophoresis, used in their analysis. This is followed by a discussion on selected clinical applications.
Collapse
|
7
|
Skin wipe test: A simple, inexpensive, and fast approach in the diagnosis of cystic fibrosis. Pediatr Pulmonol 2020; 55:1653-1660. [PMID: 32250037 DOI: 10.1002/ppul.24758] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/06/2019] [Revised: 03/04/2020] [Accepted: 03/22/2020] [Indexed: 12/28/2022]
Abstract
OBJECTIVE To assess the performance of a newly developed skin wipe test (SWT) for the diagnosis of cystic fibrosis (CF). STUDY DESIGN Spontaneously formed sweat from the forearm was wiped by a cotton swab moistened with 100 µL of deionized (DI) water and extracted into 400 µL of DI water (SWT). The conventional Macroduct sweat test (ST) was performed simultaneously. SWT samples of 114 CF patients, 76 healthy carriers, and 58 controls were analyzed by capillary electrophoresis with contactless conductivity detection and Cl- /K+ and (Cl- + Na+ )/K+ ion ratios were evaluated. Chloride concentrations from Macroduct ST were analyzed coulometrically. RESULTS Analysis of 248 SWT samples and simultaneous Macroduct ST samples showed comparable method performance. Two ion ratios, Cl- /K+ and (Cl- + Na+ )/K+ , from the SWT samples and Cl- values from the ST samples were evaluated to diagnose CF. Sensitivity of the SWT method using the Cl- /K+ ratio (cutoff value 3.9) was 93.9%, compared to 99.1% when using the (Cl- + Na+ )/K+ ratio (cutoff value 5.0) and 98.3% in using Macroduct Cl- (cutoff value higher or equal to 60 mmol/L). The methods' specificities were 97.8%, 94.0%, and 100.0%, respectively. CONCLUSIONS The developed SWT method with capillary electrophoretic analysis for CF diagnosis performs comparably to the conventional Macroduct ST. The SWT method is simple, fast, inexpensive, and completely noninvasive. Use of an ion ratio in obtained SWT samples is proposed as a new diagnostic parameter that shows significant promise in CF diagnostics.
Collapse
|
8
|
Analysis of major bile acids in saliva samples of patients with Barrett's esophagus using high-performance liquid chromatography-electrospray ionization-mass spectrometry. J Chromatogr A 2020; 1625:461278. [PMID: 32709330 DOI: 10.1016/j.chroma.2020.461278] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2020] [Revised: 05/21/2020] [Accepted: 05/23/2020] [Indexed: 01/10/2023]
Abstract
A fast, non-invasive, high-performance liquid chromatographic screening method with electrospray ionization mass spectrometric detection was developed for the analysis of three major glycine-conjugated bile acids in human saliva. Using a mobile phase composed of 80% methanol and 0.1% formic acid, glycocholic, glycodeoxycholic, and glycochenodeoxycholic acids were separated in less than 4 minutes with sensitivity in the low nM range. Bile acids are thought to contribute to the pathology of various complications in gastroesophageal reflux disease, for instance, Barrett's esophagus, which may eventually lead to esophageal carcinoma. In this pilot study, samples of saliva obtained from 15 patients with Barrett's esophagus of various severities were compared to saliva samples from 10 healthy volunteers. Glycochenodeoxycholic acid was significantly elevated in the patients and principal component analysis of all bile acids could distinguish the most severe Barrett's esophagus patients. We also reported on the detection of glycochenodeoxycholic acid in exhaled breath condensate for the first time. The promising results of this pilot study warrant future investigation, aiming at non-invasive diagnostics of Barrett's esophagus susceptibility in patients with gastroesophageal reflux disease.
Collapse
|
9
|
Capillary electrophoretic analysis of ionic content in exhaled breath condensate and pH monitoring as a non-invasive method in gastroesophageal reflux disease diagnostics. J Chromatogr B Analyt Technol Biomed Life Sci 2019; 1134-1135:121857. [DOI: 10.1016/j.jchromb.2019.121857] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2019] [Revised: 10/22/2019] [Accepted: 10/29/2019] [Indexed: 02/08/2023]
|
10
|
Analysis of bicarbonate, phosphate and other anions in saliva by capillary electrophoresis with capacitively coupled contactless conductivity detection in diagnostics of gastroesophageal reflux disease. Electrophoresis 2019; 41:116-122. [PMID: 31680268 DOI: 10.1002/elps.201900319] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2019] [Revised: 10/10/2019] [Accepted: 10/31/2019] [Indexed: 01/10/2023]
Abstract
Bicarbonate and phosphate constitute major salivary buffering components, and their importance consists in the neutralization of acidic gastric contents during reflux episodes. In this work, capillary electrophoresis with capacitively coupled contactless conductivity detector was applied for the analysis of bicarbonate, phosphate, and another inorganic (chloride, nitrite, nitrate, sulfate, thiocyanate) and organic anions (acetate, butyrate) to evaluate their levels in saliva. The background electrolytes of different composition and pH between 6.02-9.41 were assessed for the bicarbonate and phosphate determination by comparison of the real analyses of a model solution with the simulation by PeakMaster software. The optimized background electrolyte was composed of 10 mM 2-(N-morpholino)ethanesulfonic acid, 20 mM arginine, and 30 µM cetyltrimethylammonium bromide, pH 8.95. Using this BGE, the anion levels were compared in saliva from 20 patients suffering from gastroesophageal reflux disease (GERD) and saliva from 12 healthy subjects. Bicarbonate levels were significantly elevated in saliva from GERD patients suggesting the possible applicability of bicarbonate as a biomarker in non-invasive diagnostics of GERD by CE-C4 D.
Collapse
|
11
|
Optimization of background electrolyte composition for simultaneous contactless conductivity and fluorescence detection in capillary electrophoresis of biological samples. Electrophoresis 2019; 40:2390-2397. [PMID: 31218732 DOI: 10.1002/elps.201900112] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2019] [Revised: 06/14/2019] [Accepted: 06/18/2019] [Indexed: 11/07/2022]
Abstract
In this article, optimization of BGE for simultaneous separation of inorganic ions, organic acids, and glutathione using dual C4 D-LIF detection in capillary electrophoresis is presented. The optimized BGE consisted of 30 mM 2-[4-(2-hydroxyethyl)piperazin-1-yl]ethanesulfonic acid, 15 mM 2-amino-2-hydroxymethyl-propane-1,3-diol, and 2 mM 18-crown-6 at pH 7.2 and allowed simultaneous separation of ten inorganic anions and cations, three organic acids and glutathione in 20 min. The samples were injected hydrodynamically from both capillary ends using the double-opposite end injection principle. Sensitive detection of anions, cations, and organic acids with micromolar LODs using C4 D and simultaneously glutathione with nanomolar LODs using LIF was achieved in a single run. The developed BGE may be useful in analyses of biological samples containing analytes with differing concentrations of several orders of magnitude that is not possible with single detection mode.
Collapse
|
12
|
Capillary electrophoresis of small ions and molecules in less conventional human body fluid samples: A review. Anal Chim Acta 2019; 1075:1-26. [PMID: 31196414 DOI: 10.1016/j.aca.2019.05.004] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2019] [Revised: 05/02/2019] [Accepted: 05/03/2019] [Indexed: 01/05/2023]
Abstract
In recent years, advances in sensitive analytical techniques have encouraged the analysis of various compounds in biological fluids. While blood serum, blood plasma and urine still remain the golden standards in clinical, toxicological and forensic science, analyses of other body fluids, such as breast milk, exhaled breath condensate, sweat, saliva, amniotic fluid, cerebrospinal fluid, or capillary blood in form of dried blood spots are becoming more popular. This review article focuses on capillary electrophoresis and microchip electrophoresis of small ions and molecules (e.g. inorganic cations/anions, basic/acidic drugs, small acids/bases, amino acids, peptides and other low molecular weight analytes) in various less conventional human body fluids and hopes to stimulate further interest in the field.
Collapse
|
13
|
Open source capillary electrophoresis. Electrophoresis 2018; 40:65-78. [PMID: 30229967 DOI: 10.1002/elps.201800304] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2018] [Revised: 08/17/2018] [Accepted: 08/17/2018] [Indexed: 12/17/2022]
Abstract
Open source paradigm is becoming widely accepted in scientific communities and open source hardware is finding its steady place in chemistry research. In this review article, we provide the reader with the most up-to-date information on open source hardware and software resources enabling the construction and utilization of an "open source capillary electrophoresis instrument". While CE is still underused as a separation technique, it offers unique flexibility, low-cost, and high efficiency and is particularly suitable for open source instrumental development. We overview the major parts of CE instruments, such as high voltage power supplies, detectors, data acquisition systems, and CE software resources with emphasis on availability of the open source information on the web and in the scientific literature. This review is the first of its kind, revealing accessible blueprints of most parts from which a fully functional open source CE system can be built. By collecting the extensive information on open source capillary electrophoresis in this review article, the authors aim at facilitating the dissemination of knowledge on CE within and outside the scientific community, fosters innovation and inspire other researchers to improve the shared CE blueprints.
Collapse
|
14
|
Sensitive determination of malondialdehyde in exhaled breath condensate and biological fluids by capillary electrophoresis with laser induced fluorescence detection. Talanta 2017; 169:85-90. [DOI: 10.1016/j.talanta.2017.03.061] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2017] [Accepted: 03/17/2017] [Indexed: 12/16/2022]
|
15
|
New approach for cystic fibrosis diagnosis based on chloride/potassium ratio analyzed in non-invasively obtained skin-wipe sweat samples by capillary electrophoresis with contactless conductometric detection. Anal Bioanal Chem 2017; 409:3507-3514. [PMID: 28357484 DOI: 10.1007/s00216-017-0318-6] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2017] [Revised: 02/22/2017] [Accepted: 03/14/2017] [Indexed: 11/30/2022]
Abstract
A new approach for sweat analysis used in cystic fibrosis (CF) diagnosis is proposed. It consists of a noninvasive skin-wipe sampling followed by analysis of target ions using capillary electrophoresis with contactless conductometric detection (C4D). The skin-wipe sampling consists of wiping a defined skin area with precleaned cotton swab moistened with 100 μL deionized water. The skin-wipe sample is then extracted for 3 min into 400 μL deionized water, and the extract is analyzed directly. The developed sampling method is cheap, simple, fast, and painless, and can replace the conventional pilocarpine-induced sweat chloride test commonly applied in CF diagnosis. The aqueous extract of the skin-wipe sample content is analyzed simultaneously by capillary electrophoresis with contactless conductometric detection using a double opposite end injection. A 20 mmol/L L-histidine/2-(N-morpholino)ethanesulfonic acid and 2 mmol/L 18-crown-6 at pH 6 electrolyte can separate all the major ions in less than 7 min. Skin-wipe sample extracts from 30 study participants-ten adult patients with CF (25-50 years old), ten pediatric patients with CF (1-15 years old), and ten healthy control individuals (1-18 years old)-were obtained and analyzed. From the analyzed ions in all samples, a significant difference between chloride and potassium concentrations was found in the CF patients and healthy controls. We propose the use of the Cl-/K+ ratio rather than the absolute Cl- concentration and a cutoff value of 4 in skin-wipe sample extracts as an alternative to the conventional sweat chloride analysis. The proposed Cl-/K+ ion ratio proved to be a more reliable indicator, is independent of the patient's age, and allows better differentiation between non-CF individuals and CF patients having intermediate values on the Cl- sweat test. Figure New approach for cystic fibrosis diagnosis based on skin-wipe sampling of forearm and analysis of ionic content (Cl-/K+ ratio) in skin-wipe extracts by capillary electrophoresis with contactless conductometric detection.
Collapse
|
16
|
Capillary electrophoresis in the analysis of biologically important thiols. Electrophoresis 2016; 38:203-222. [DOI: 10.1002/elps.201600354] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2016] [Revised: 08/30/2016] [Accepted: 08/31/2016] [Indexed: 12/21/2022]
|
17
|
Capillary electrophoresis fingerprinting and spectrophotometric determination of antioxidant potential for classification ofMenthaproducts. J Sep Sci 2016; 39:2862-8. [DOI: 10.1002/jssc.201600235] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2016] [Revised: 05/10/2016] [Accepted: 05/14/2016] [Indexed: 11/10/2022]
|
18
|
Analysis of Organic Acids, Deacetyl Asperulosidic Acid and Polyphenolic Compounds as a Potential Tool for Characterization of Noni (Morinda citrifolia) Products. Nat Prod Commun 2015. [DOI: 10.1177/1934578x1501001107] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Organic acids, deacetyl asperulosidic acid (DAA) and polyphenolic compounds in various noni ( Morinda citrifolia L.) products (4 juices, 4 dry fruit powders and 2 capsules with dry fruit powder) were analyzed. Reversed-phase high-performance liquid chromatography (RP-HPLC) coupled with a variable wavelength detector (VWD) and electrospray ionization time-of-flight mass spectrometer (ESI-TOF MS) was applied for simultaneous analysis of organic acids (malic, lactic, citric and succinic acid) and DAA. An RP-HPLC method with diode-array detector (DAD) was developed for the analysis of polyphenolic compound content (rutin, catechin, quercitrin, kaempferol, gallic acid, caffeic acid and p-coumaric acid). The developed methods can contribute to better characterization of available noni products that is required from the consumers. In our study, we discovered significant dissimilarities in the content of DAA, citric acid and several phenolic compounds in some samples.
Collapse
|
19
|
Monitoring the ionic content of exhaled breath condensate in various respiratory diseases by capillary electrophoresis with contactless conductivity detection. J Breath Res 2015; 9:027107. [PMID: 25944821 DOI: 10.1088/1752-7155/9/2/027107] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
The analysis of an ionic profile of exhaled breath condensate (EBC) by capillary electrophoresis with contactless conductivity detection and double opposite end injection, is demonstrated. A miniature sampler made from a 2 ml syringe and an aluminium cooling cylinder was used for the fast collection of EBC (under one minute). Analysis of the collected EBC was performed in a 60 mM 2-(N-morpholino)ethanesulfonic acid, 60 mM L-histidine background electrolyte with 30 µM cetyltrimethylammonium bromide and 2 mM 18-crown-6 at pH 6, and excellent repeatability of migration times (RSD <1.3% (n = 7)) and peak areas (RSD < 7% (n = 7)) of 14 ions (inorganic anions, cations and organic acids) was obtained. It is demonstrated that the analysis of EBC samples obtained from patients with various respiratory diseases (chronic obstructive pulmonary disease, asthma, pulmonary fibrosis, sarcoidosis, cystic fibrosis) is possible in less than five minutes and the ionic profile can be compared with the group of healthy individuals. The analysis of the ionic profile of EBC samples provides a set of data in which statistically significant differences among the groups of patients could be observed for several clinically relevant anions (nitrite, nitrate, acetate, lactate). The developed collection system and method provides a highly reproducible and fast way of collecting and analyzing EBC, with future applicability in point-of-care diagnostics.
Collapse
|
20
|
Sensitive determination of glutathione in biological samples by capillary electrophoresis with green (515nm) laser-induced fluorescence detection. J Chromatogr A 2015; 1391:102-8. [DOI: 10.1016/j.chroma.2015.02.062] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2014] [Revised: 02/02/2015] [Accepted: 02/20/2015] [Indexed: 10/23/2022]
|
21
|
Single-breath analysis using a novel simple sampler and capillary electrophoresis with contactless conductometric detection. Electrophoresis 2015; 36:526-33. [PMID: 25377628 DOI: 10.1002/elps.201400456] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2014] [Revised: 10/29/2014] [Accepted: 10/29/2014] [Indexed: 11/11/2022]
Abstract
The analysis of ionic content of exhaled breath condensate (EBC) from one single breath by CE with C(4) D is demonstrated for the first time. A miniature sampler made from a 2-mL syringe and an aluminum cooling cylinder for collection of EBC was developed. Various parameters of the sampler that influence its collection efficiency, repeatability, and effect of respiratory patterns were studied in detail. Efficient procedures for the cleanup of the miniature sampler were also developed and resulted in significant improvement of sampling repeatability. Analysis of EBC was performed by CE-C(4) D in a 60 mM MES/l-histidine BGE with 30 μM CTAB and 2 mM 18-crown-6 at pH 6 and excellent repeatability of migration times (RSD < 1.3% (n = 7)) and peak areas (RSD < 7% (n = 7)) of 12 inorganic anions, cations, and organic acids was obtained. It has been shown that the breathing pattern has a significant impact on the concentration of the analytes in the collected EBC. As the ventilatory pattern can be easily controlled during single exhalation, the developed collection system and method provides a highly reproducible and fast way of collecting EBC with applicability in point-of-care diagnostics.
Collapse
|
22
|
Double opposite end injection capillary electrophoresis with contactless conductometric detection for simultaneous determination of chloride, sodium and potassium in cystic fibrosis diagnosis. J Chromatogr A 2014; 1358:293-8. [DOI: 10.1016/j.chroma.2014.06.091] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2014] [Revised: 06/25/2014] [Accepted: 06/27/2014] [Indexed: 10/25/2022]
|
23
|
Fingerprinting postblast explosive residues by portable capillary electrophoresis with contactless conductivity detection. Electrophoresis 2014; 35:1165-72. [DOI: 10.1002/elps.201300380] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2013] [Revised: 10/10/2013] [Accepted: 12/10/2013] [Indexed: 11/10/2022]
|
24
|
Exhaled breath condensate: Determination of non-volatile compounds and their potential for clinical diagnosis and monitoring. A review. Anal Chim Acta 2013; 805:1-18. [DOI: 10.1016/j.aca.2013.07.049] [Citation(s) in RCA: 105] [Impact Index Per Article: 9.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2013] [Revised: 07/16/2013] [Accepted: 07/20/2013] [Indexed: 12/31/2022]
|
25
|
Inorganic analysis using CE: Advanced methodologies to face old challenges. Electrophoresis 2013; 35:225-33. [DOI: 10.1002/elps.201300302] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2013] [Revised: 08/19/2013] [Accepted: 08/19/2013] [Indexed: 12/28/2022]
|
26
|
Capillary electrophoresis with contactless conductometric detection for rapid screening of formate in blood serum after methanol intoxication. J Chromatogr A 2013; 1281:142-7. [DOI: 10.1016/j.chroma.2013.01.035] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2012] [Revised: 01/04/2013] [Accepted: 01/07/2013] [Indexed: 10/27/2022]
|
27
|
Determination of five priority haloacetic acids by capillary electrophoresis with contactless conductivity detection and solid phase extraction preconcentration. J Sep Sci 2012; 35:666-73. [DOI: 10.1002/jssc.201100944] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
28
|
CE of inorganic species - A review of methodological advancements over 2009-2010. Electrophoresis 2011; 33:196-210. [DOI: 10.1002/elps.201100357] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2011] [Revised: 07/30/2011] [Accepted: 07/30/2011] [Indexed: 01/13/2023]
|
29
|
In situ determination of nerve agents in various matrices by portable capillary electropherograph with contactless conductivity detection. J Chromatogr A 2011; 1218:2618-25. [DOI: 10.1016/j.chroma.2011.03.006] [Citation(s) in RCA: 41] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2011] [Revised: 03/03/2011] [Accepted: 03/07/2011] [Indexed: 11/29/2022]
|
30
|
Improving precision of manual hydrodynamic injection in capillary electrophoresis with contactless conductivity detection. J Chromatogr A 2011; 1218:1273-80. [DOI: 10.1016/j.chroma.2010.12.107] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2010] [Revised: 12/20/2010] [Accepted: 12/24/2010] [Indexed: 11/16/2022]
|
31
|
Analysis of inorganic cations in biological samples by the combination of micro-electrodialysis and capillary electrophoresis with capacitively coupled contactless conductivity detection. Electrophoresis 2011; 32:464-71. [DOI: 10.1002/elps.201000423] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2010] [Revised: 10/27/2010] [Accepted: 11/16/2010] [Indexed: 11/12/2022]
|
32
|
Polyelectrolyte multilayers as stationary phases for open tubular ion chromatography. J Chromatogr A 2009; 1216:9022-6. [DOI: 10.1016/j.chroma.2009.10.067] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2009] [Revised: 10/21/2009] [Accepted: 10/23/2009] [Indexed: 10/20/2022]
|
33
|
Capillary electrochromatography of inorganic cations in open tubular columns with a controllable capacity multilayered stationary phase architecture. J Chromatogr A 2008; 1190:377-82. [DOI: 10.1016/j.chroma.2008.03.022] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2008] [Revised: 03/03/2008] [Accepted: 03/06/2008] [Indexed: 11/15/2022]
|
34
|
Gas Diffusion-Flow Injection Determination of Free and Total Sulfur Dioxide in Wines by Conductometry. ACTA ACUST UNITED AC 1998. [DOI: 10.1135/cccc19980770] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Sensitive flow injection analysis methods for the determination of free and total sulfur dioxide in wines are presented. The bound S(IV) was liberated by alkaline hydrolysis with 4 mol/l NaOH. All forms of S(IV) were liberated from the sample zone by sulfuric acid and subsequently transported through a microporous PVDF membrane. The penetrated gases were collected in water for preselected period and determined by conductometry with detection limit 1 mg/l and relative standard deviations 0.8 and 0.6% at 10 and 150 mg/l (n = 10) for free and total S(IV), respectively. The results are comparable with those obtained by standard titrimetric procedures with visual (Czech State Standard) and/or potentiometric indication.
Collapse
|