1
|
Is the use of gonad protection protectors necessary during infants chest radiography? RADIOLOGIA 2024; 66:107-113. [PMID: 38614527 DOI: 10.1016/j.rxeng.2022.08.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Accepted: 08/21/2022] [Indexed: 04/15/2024]
Abstract
INTRODUCTION AND OBJECTIVES To compare gonad doses with and without a gonad protector and to optimize the use of gonadal protectors in infants thorax radiography. MATERIALS AND METHODS Two pediatric anthropomorphic phantoms are used: an X-ray system for KXO-50SS/DRX-3724HD, and a digital radiography system for CALNEO Smart C12, with and without a gonad protector during infants thorax radiography. A real time skin dosimeter is placed on the X-ray system, and a real time skin dosimeter is inserted on the front side of the mammary gland, the front and back sides of the true pelvis level, and on the ovaries and testes. The X-ray system is irradiated 15 times using phantoms with and without a gonad protector. The measured entrance patient doses values of for the real time skin dosimeter are compared for each phantom, with and without the gonad protector. RESULTS The medium of measured entrance patient doses values for front side dose of the true pelvis level with and without the protector are 10.00 and 5.00 μGy at newborn, and 10.00 and 0.00μGy at one year, respectively. The medium of measured entrance patient doses values for the back side dose of the true pelvis level with and without the protector are 0.00 and 0.00 μGy at both newborn one year, respectively. The measured entrance patient doses cannot be detected in the ovaries and testes with or without the protector. No significant differences are observed in the measured entrance patient doses values for the front and back side doses of the pelvis, ovaries, and testes at newborn and one year, with and without the protector (p>0.05). CONCLUSIONS No significant difference was observed in gonad dose measurements with and without the gonad protector during infants chest radiography. We believe that gonadal protector wearing is not necessary.
Collapse
|
2
|
[Questionnaire Survey of Hands-on Seminar Using a Web Conferencing System in the COVID-19 Pandemic]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2023; 79:932-940. [PMID: 37495539 DOI: 10.6009/jjrt.2023-1354] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/28/2023]
Abstract
The purpose of this study was to evaluate the effectiveness of a hands-on seminar using a Web conferencing system, based on the post-event questionnaires of the face-to-face and online seminars of the hands-on seminar. For participants to feel realistic training in the online seminars, four educational videos explaining the procedure of the practical skill were created. We compared results of questionnaires acquired from participants after the face-to-face and online seminars. The questions about expectation, comprehension, satisfaction level, and lecture time for the seminars were graded on a 5-point scale. The higher the scores, the higher the rating, except for lecture time. A score of 3 was appropriate for the lecture time, with a higher score indicating that the seminar felt longer and a lower score indicating that the seminar felt shorter. In the evaluation of classroom lectures, such as expectation, comprehension, and satisfaction level for the seminars, there were no significant differences between the face-to-face and online seminars, and both achieved high scores of 4 or more. There was a significant difference in the evaluation of lecture time for classroom lectures, with participants feeling that it was too short in the face-to-face but just right in the online. In all evaluations for hands-on training and discussion, there were no significant differences between the face-to-face and online seminars, and both achieved high scores of 4 or more and time was short. It was concluded that our proposed online seminar approach could achieve a high level of evaluation as face-to-face seminars.
Collapse
|
3
|
Evaluation of In-room Volumetric Imaging Doses for Image-guided Radiotherapy: A Multi-institutional Study. J Med Phys 2023; 48:189-194. [PMID: 37576099 PMCID: PMC10419753 DOI: 10.4103/jmp.jmp_109_22] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2022] [Revised: 05/10/2023] [Accepted: 05/22/2023] [Indexed: 08/15/2023] Open
Abstract
Aims We investigated imaging dose and noise under clinical scan conditions at multiple institutions using a simple and unified method, and demonstrated the need for diagnostic reference levels in image-guided radiotherapy (IGRT). Materials and Methods Nine cone-beam and helical computed tomography (CT) scanners (Varian, Elekta, Accuray Inc., and BrainLAB) from seven institutions were investigated in this study. The weighted cone-beam dose index (CBDIw) was calculated for head and pelvic protocols using a 100 mm pencil chamber under the conditions used in actual clinical practice at each institution. Cone-beam CT image noise was evaluated using polymethylmethacrylate head and body phantoms with diameters of 16 and 32 cm, respectively. Results For head and pelvic protocols, CBDIw values ranged from 0.94-6.59 and 1.47-20.9 mGy, respectively. Similarly, standard deviation (SD) values ranged from 9.3-34.0 and 26.9-97.4 HU, respectively. The SD values tended to increase with decreasing imaging dose (r = -0.33 and -0.61 for the head and pelvic protocols, respectively). Conclusions Among the nine machines, the imaging dose for high imaging dose institutions was approximately 20 mGy to the pelvic phantom, and there was a 14-fold difference in dose compared with the other institutions. These results suggest the need to establish DRLs for IGRT to guide clinical decision-making.
Collapse
|
4
|
Formation and evolution of carbonaceous asteroid Ryugu: Direct evidence from returned samples. Science 2023; 379:eabn8671. [PMID: 36137011 DOI: 10.1126/science.abn8671] [Citation(s) in RCA: 20] [Impact Index Per Article: 20.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
Abstract
Samples of the carbonaceous asteroid Ryugu were brought to Earth by the Hayabusa2 spacecraft. We analyzed 17 Ryugu samples measuring 1 to 8 millimeters. Carbon dioxide-bearing water inclusions are present within a pyrrhotite crystal, indicating that Ryugu's parent asteroid formed in the outer Solar System. The samples contain low abundances of materials that formed at high temperatures, such as chondrules and calcium- and aluminum-rich inclusions. The samples are rich in phyllosilicates and carbonates, which formed through aqueous alteration reactions at low temperature, high pH, and water/rock ratios of <1 (by mass). Less altered fragments contain olivine, pyroxene, amorphous silicates, calcite, and phosphide. Numerical simulations, based on the mineralogical and physical properties of the samples, indicate that Ryugu's parent body formed ~2 million years after the beginning of Solar System formation.
Collapse
|
5
|
[Usefulness of an Ultrasound System with Automatic Bladder Urine Volume Measurement Using Artificial Intelligence Technology in Radiotherapy]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2022; 78:1406-1414. [PMID: 36198613 DOI: 10.6009/jjrt.2022-1316] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
PURPOSE We aimed to investigate the usefulness of iViz air ver.4 Convex (FUJIFILM, Tokyo) as a tool to determine the bladder capacity before prostate radiotherapy by comparing it with the existing BladderScan BVI 6100 (Verathon Inc., Bothell, Washington). METHODS We investigated the usefulness of iViz air as a tool to determine the bladder capacity before prostate radiotherapy by comparing it with the current BladderScan. RESULTS The absolute value of each error rate was approximately 30.9%±27.2% and 26.4%±18.9% for the BladderScan and iViz air, respectively, with no significant differences between the instruments (p=0.16). Evaluated by urine volume, the mean error rates for bladder volumes >50 ml were 26.9%±19.0% and 26.1%±18.5% for the Bladder Scan and iViz air, respectively, with no significant differences (p=0.56). However, the BladderScan and iViz air had significantly higher error rates of 89.5%±52.5% and 31.5%±25.1%, respectively, if the bladder volume was <50 ml (p=0.005). CONCLUSION The iViz air has limited measurement error to confirm images, especially in limited volumes, suggesting that it is a useful bladder capacity measurement device in performing prostate radiotherapy.
Collapse
|
6
|
¿Es necesario utilizar protectores de gónadas durante la realización de radiografías de tórax en los lactantes? RADIOLOGIA 2022. [DOI: 10.1016/j.rx.2022.08.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
7
|
Pebbles and sand on asteroid (162173) Ryugu: In situ observation and particles returned to Earth. Science 2022; 375:1011-1016. [PMID: 35143255 DOI: 10.1126/science.abj8624] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
The Hayabusa2 spacecraft investigated the C-type (carbonaceous) asteroid (162173) Ryugu. The mission performed two landing operations to collect samples of surface and subsurface material, the latter exposed by an artificial impact. We present images of the second touchdown site, finding that ejecta from the impact crater was present at the sample location. Surface pebbles at both landing sites show morphological variations ranging from rugged to smooth, similar to Ryugu's boulders, and shapes from quasi-spherical to flattened. The samples were returned to Earth on 6 December 2020. We describe the morphology of >5 grams of returned pebbles and sand. Their diverse color, shape, and structure are consistent with the observed materials of Ryugu; we conclude that they are a representative sample of the asteroid.
Collapse
|
8
|
A novel real-time shapeable soft rubber bolus for clinical use in electron radiotherapy. Phys Med Biol 2021; 66. [PMID: 34438390 DOI: 10.1088/1361-6560/ac215b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2021] [Accepted: 08/26/2021] [Indexed: 11/12/2022]
Abstract
We have developed soft rubber (SR) bolus that can be shaped in real-time by heating flexibly and repeatedly. This study investigated whether the SR bolus could be used as an ideal bolus, such as not changing of the beam characteristics and homogeneity through the bolus and high plasticity to adhere a patient in addition to real-time shapeable and reusability, in electron radiotherapy. Percentage depth doses (PDDs) and lateral dose profiles (LDPs) were obtained for 4, 6, and 9 MeV electron beams and were compared between the SR and conventional gel boluses. For the LDP at depth of 90% dose, the penumbra as lateral distance between the 80% and 20% isodose lines (P80-20) and the width of 90% dose level (r90) were compared. To evaluate adhesion, the air gap volume between the boluses and nose of a head phantom was evaluated on CT image. The dose profiles along the center axis for the 6 MeV electron beam with SR, gel, and virtual boluses (thickness = 5 mm) on the head phantom were also calculated for the irradiation of 200 monitor unit with a treatment planning system and the depth of the maximum dose (dmax) and maximum dose (Dmax) were compared. The PDDs,P80-20, andr90between the SR and gel boluses corresponded well (within 2%, 0.4 mm, and 0.7 mm, respectively). The air gap volumes of the SR and gel boluses were 3.14 and 50.35 cm3, respectively. Thedmaxwith SR, gel and virtual boluses were 8.0, 6.0, and 7.0 mm (no bolus: 12.0 mm), and theDmaxvalues were 186.4, 170.6, and 186.8 cGy, respectively. The SR bolus had the equivalent electron beam characteristics and homogeneity to the gel bolus and achieved excellent adhesion to a body surface, which can be used in electron radiotherapy as an ideal bolus.
Collapse
|
9
|
[7. Data Management in Radiation Therapy]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2021; 77:604-611. [PMID: 34148903 DOI: 10.6009/jjrt.2021_jsrt_77.6.604] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
10
|
Dosimetric evaluation of skin collimation with tungsten rubber for electron radiotherapy: A Monte Carlo study. J Appl Clin Med Phys 2021; 22:63-70. [PMID: 33634955 PMCID: PMC8035551 DOI: 10.1002/acm2.13210] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2020] [Revised: 02/02/2021] [Accepted: 02/04/2021] [Indexed: 11/15/2022] Open
Abstract
PURPOSE Skin collimation provides a sharp penumbra for electron beams, while the effect of bremsstrahlung from shielding materials is a concern. This phantom study was conducted to evaluate the safety and efficacy of a real-time variable shape rubber containing-tungsten (STR) that can be placed on a patient's skin. METHODS Electron beam profiles were acquired with the STR placed on a water-equivalent phantom and low melting-point alloy (LMA) placed at the applicator according to commonly used procedures (field sizes: 20- and 40-mm diameters). Depth and lateral dose profiles for 6- and 12-MeV electron beams were obtained by Monte Carlo (MC) simulations and were benchmarked against film measurements. The width of the off-axis distance between 80% and 20% doses (P80-20 ) and the maximum dose were obtained from the lateral dose profiles. Bremsstrahlung emission was analyzed by MC simulations at the depth of maximum dose (R100 ). RESULTS The depth dose profiles calculated by the MC simulations were consistently within 2% of the measurements. The P80-20 at R100 for 20- and 40-mm diameters were 4.0 mm vs. 7.6 mm (STR vs. LMA) and 4.5 mm vs. 9.2 mm, respectively, for the 6-MeV electron beam with 7.0-mm-thick STR, and 2.7 mm vs. 5.6 mm and 4.5 mm vs. 7.1 mm, respectively, for the 12-MeV electron beam with 12.0-mm-thick STR. A hotspot was not observed on the lateral dose profiles obtained with the STR at R100 . The bremsstrahlung emission under the region shielded by the STR was comparable to that obtained with the LMA, even though the STR was placed on the surface of the phantom. CONCLUSIONS Skin collimator with STR provided superior dosimetric characteristics and comparable bremsstrahlung emission to LMA collimator at the applicator. STR could be a new tool for the safe and efficient delivery of electron radiotherapy.
Collapse
|
11
|
[4. Independent Verification of the Monitor Unit Using a Simple Method]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2021; 77:212-219. [PMID: 33612699 DOI: 10.6009/jjrt.2021_jsrt_77.2.212] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
12
|
[Application of Real-time Variable Shape Tungsten Rubber for Nail Radiation Protection in the Total Skin Electron Beam (TSEB) Therapy]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2021; 77:145-152. [PMID: 33612692 DOI: 10.6009/jjrt.2021_jsrt_77.2.145] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
PURPOSE This study investigated whether real-time variable shape tungsten rubber (STR) could be applied for nail radiation protection in total skin electron beam (TSEB) therapy. METHODS Simulated finger phantoms were made from syringes filled with physiological saline of volumes 5, 10, 20, and 30 ml (inner diameters of 14.1, 17.0, 21.7, and 25.3 mm, respectively). Gafchromic film was applied to the phantom, and lead (thickness 1-3 mm) or STR (thickness 1-4 mm) with an area of 4´1.5 cm was used to cover the film. A 6 MeV electron beam with an 8 mm acrylic board was then used to irradiate the phantom. The source-surface distance (SSD) was 444 cm, the field size was 36´36 cm at SSD of 100 cm without an electron applicator, and the monitor unit was 2000 MU. The shielding rates were obtained from the dose profiles. RESULTS The mean values of the shielding rate values for all phantoms were 50.1, 97.6, and 98.7% for 1, 2, and 3 mm of lead, respectively, and -13.6, 53.9, 91.2, and 99.4% for 1, 2, 3, and 4 mm of STR, respectively. CONCLUSION STR with a thickness of 4 mm had the same shielding properties as lead with a thickness of 3 mm, which was an approximately 100% shielding rate. STR could therefore be used in TSEB therapy instead of lead.
Collapse
|
13
|
Dose reduction potential of using gold fiducial markers for kilovoltage image-guided radiotherapy. J Appl Clin Med Phys 2020; 21:151-157. [PMID: 32959957 PMCID: PMC7592977 DOI: 10.1002/acm2.13023] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2019] [Revised: 08/07/2020] [Accepted: 08/09/2020] [Indexed: 12/19/2022] Open
Abstract
This study aimed to evaluate the possibility of reducing the imaging dose for image-guided radiotherapy by using planar kilovoltage orthogonal imaging and fiducial markers (kV-FM). We tested kilovoltage planar images under clinical imaging conditions for the pelvis (75 kVp, 200 mA, 50 ms) at a decreasing tube current (from 200 to 10 mA). Imaging doses were measured with a semiconductor detector. The visibility of the kV-FM, aspects of image quality (spatial resolution, low contrast resolution), and the resultant image registration reproducibility were evaluated using various shapes (folded, linear, tadpole-like) of fiducial markers containing 0.5% iron [Gold Anchor™ (GA); Naslund Medical AB, Huddinge, Sweden]. The GA phantom was created by placing these variously shaped GAs in an agar phantom. The imaging doses with 200 and 10 mA were approximately 0.74 and 0.04 mGy and they were correlated to the tube current (R2 = 0.999). Regardless of the marker's shape, the GA phantom ensured visibility even when the tube current was reduced to the minimum value (10 mA). The low contrast resolution was gradually decreased at less than 50 mA, but the spatial resolution did not change. Although the auto-registration function could not be used, manual-registration could be achieved with an accuracy of within 1 mm, even when the imaging dose was reduced to 1/20 of the clinical imaging condition for the pelvis. When using the GA as the fiducial marker, the imaging dose could be reduced to 1/20 of that used clinically while maintaining the accuracy of manual-registration using the kV-FM for image-guided radiotherapy of the pelvis.
Collapse
|
14
|
Feasibility of using tungsten functional paper as a thin bolus for electron beam radiotherapy. Phys Eng Sci Med 2020; 43:1101-1111. [PMID: 32785883 DOI: 10.1007/s13246-020-00910-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2019] [Accepted: 07/25/2020] [Indexed: 11/30/2022]
Abstract
Containing 80% tungsten by weight, tungsten functional paper (TFP) is a radiation-shielding material that is lightweight, flexible, disposable, and easy to cut. Through experimental measurements and Monte Carlo simulations, we investigated the feasibility of using TFP as a bolus in electron beam radiotherapy. Commercial boluses of thickness 5 and 10 mm and from one to nine layers of TFPs (0.3-2.7 mm) were positioned on the surface of water-equivalent phantoms. The percentage depth dose curves and transverse dose profiles were measured using a 9-MeV electron beam from a clinical linear accelerator. Normalized to the value at the depth of maximum dose without bolus, the relative doses at the phantom surface for no bolus, 5-mm bolus, 10-mm bolus, 1 TFP, 3 TFPs, 6 TFPs, and 9 TFPs were 78%, 88%, 92%, 84%, 92%, 102%, and 112%, respectively; the therapeutic depths corresponding to a 90% dose level were 29.1 mm, 22.7 mm, 17.7 mm, 26.6 mm, 23.2 mm, 19.3 mm, and 15.8 mm, respectively. The TFP contributed to increased skin dose and provided dose uniformity within the target volume. However, it also resulted in increased lateral constriction and penumbra width. The results of Monte Carlo simulation produced similar trends as the experimental measurements. Our findings suggest that using TFP as a novel thin and flexible skin bolus for electron beam radiotherapy is feasible.
Collapse
|
15
|
Sample collection from asteroid (162173) Ryugu by Hayabusa2: Implications for surface evolution. Science 2020; 368:654-659. [DOI: 10.1126/science.aaz6306] [Citation(s) in RCA: 104] [Impact Index Per Article: 26.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2019] [Accepted: 04/02/2020] [Indexed: 11/02/2022]
|
16
|
An artificial impact on the asteroid (162173) Ryugu formed a crater in the gravity-dominated regime. Science 2020; 368:67-71. [PMID: 32193363 DOI: 10.1126/science.aaz1701] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2019] [Accepted: 03/04/2020] [Indexed: 11/02/2022]
Abstract
The Hayabusa2 spacecraft investigated the small asteroid Ryugu, which has a rubble-pile structure. We describe an impact experiment on Ryugu using Hayabusa2's Small Carry-on Impactor. The impact produced an artificial crater with a diameter >10 meters, which has a semicircular shape, an elevated rim, and a central pit. Images of the impact and resulting ejecta were recorded by the Deployable CAMera 3 for >8 minutes, showing the growth of an ejecta curtain (the outer edge of the ejecta) and deposition of ejecta onto the surface. The ejecta curtain was asymmetric and heterogeneous and it never fully detached from the surface. The crater formed in the gravity-dominated regime; in other words, crater growth was limited by gravity not surface strength. We discuss implications for Ryugu's surface age.
Collapse
|
17
|
Registration accuracy with the low dose kilovoltage cone-beam CT: A phantom study. BJR Open 2019; 1:20190028. [PMID: 33178952 PMCID: PMC7592495 DOI: 10.1259/bjro.20190028] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Revised: 07/31/2019] [Accepted: 08/18/2019] [Indexed: 12/29/2022] Open
Abstract
Objective: The aim of this study was to investigate low-dose kilovoltage cone-beam CT (kV-CBCT) for image-guided radiotherapy, with a particular focus on the accuracy of image registration with low-dose protocols. Methods: Imaging doses were measured with a NOMEX semiconductor detector positioned at the front of head, thorax, and pelvis human body phantoms while kV-CBCT scans were acquired at different tube currents. Aspects of image quality (spatial resolution, noise, uniformity, contrast, geometric distortion, and Hounsfield unit sensitivity) and image registration accuracy using bone and soft tissue were evaluated. Results: With preset and the lowest tube currents, the imaging doses were 0.16 and 0.08 mGy, 5.29 and 2.80 mGy, and 18.23 and 2.69 mGy for head, thorax, and pelvis, respectively. Noise was the only quality aspect directly dependent on tube current, being increased by 1.5 times with a tube current half that of the preset in head and thorax, and by 2.2 times with a tube current 1/8 of the preset in the pelvis. Accurate auto-bone matching was performed within 1 mm at the lowest tube current. The auto-soft tissue matching could not be performed with the lowest tube current; however, manual-soft tissue matching could still be performed within 2 mm or less. Conclusion: Noise was the only image quality aspect dependent on the imaging dose. Auto-bone and manual-soft tissue matching could still be performed at the lowest imaging dose. Advances in knowledge: When optimizing kV-CBCT imaging dose, the impact on bone and soft tissue image registration accuracy should be evaluated.
Collapse
|
18
|
Gastrointestinal: A case of small bowel obstruction caused by a bezoar, preoperatively found by double-balloon enteroscopy. J Gastroenterol Hepatol 2019; 34:962. [PMID: 30693556 DOI: 10.1111/jgh.14589] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Accepted: 12/28/2018] [Indexed: 12/09/2022]
|
19
|
Predictors for pathological parametrial invasion in clinical stage iib cervical cancer: A nation-wide cohort study. Gynecol Oncol 2019. [DOI: 10.1016/j.ygyno.2019.04.637] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
20
|
Hayabusa2 arrives at the carbonaceous asteroid 162173 Ryugu-A spinning top-shaped rubble pile. Science 2019; 364:268-272. [PMID: 30890588 DOI: 10.1126/science.aav8032] [Citation(s) in RCA: 46] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2018] [Accepted: 03/07/2019] [Indexed: 11/02/2022]
Abstract
The Hayabusa2 spacecraft arrived at the near-Earth carbonaceous asteroid 162173 Ryugu in 2018. We present Hayabusa2 observations of Ryugu's shape, mass, and geomorphology. Ryugu has an oblate "spinning top" shape, with a prominent circular equatorial ridge. Its bulk density, 1.19 ± 0.02 grams per cubic centimeter, indicates a high-porosity (>50%) interior. Large surface boulders suggest a rubble-pile structure. Surface slope analysis shows Ryugu's shape may have been produced from having once spun at twice the current rate. Coupled with the observed global material homogeneity, this suggests that Ryugu was reshaped by centrifugally induced deformation during a period of rapid rotation. From these remote-sensing investigations, we identified a suitable sample collection site on the equatorial ridge.
Collapse
|
21
|
The surface composition of asteroid 162173 Ryugu from Hayabusa2 near-infrared spectroscopy. Science 2019; 364:272-275. [PMID: 30890589 DOI: 10.1126/science.aav7432] [Citation(s) in RCA: 40] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Accepted: 03/07/2019] [Indexed: 11/02/2022]
Abstract
The near-Earth asteroid 162173 Ryugu, the target of the Hayabusa2 sample-return mission, is thought to be a primitive carbonaceous object. We report reflectance spectra of Ryugu's surface acquired with the Near-Infrared Spectrometer (NIRS3) on Hayabusa2, to provide direct measurements of the surface composition and geological context for the returned samples. A weak, narrow absorption feature centered at 2.72 micrometers was detected across the entire observed surface, indicating that hydroxyl (OH)-bearing minerals are ubiquitous there. The intensity of the OH feature and low albedo are similar to thermally and/or shock-metamorphosed carbonaceous chondrite meteorites. There are few variations in the OH-band position, which is consistent with Ryugu being a compositionally homogeneous rubble-pile object generated from impact fragments of an undifferentiated aqueously altered parent body.
Collapse
|
22
|
The geomorphology, color, and thermal properties of Ryugu: Implications for parent-body processes. Science 2019; 364:252. [PMID: 30890587 DOI: 10.1126/science.aaw0422] [Citation(s) in RCA: 44] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2018] [Accepted: 03/12/2019] [Indexed: 11/02/2022]
Abstract
The near-Earth carbonaceous asteroid 162173 Ryugu is thought to have been produced from a parent body that contained water ice and organic molecules. The Hayabusa2 spacecraft has obtained global multicolor images of Ryugu. Geomorphological features present include a circum-equatorial ridge, east-west dichotomy, high boulder abundances across the entire surface, and impact craters. Age estimates from the craters indicate a resurfacing age of [Formula: see text] years for the top 1-meter layer. Ryugu is among the darkest known bodies in the Solar System. The high abundance and spectral properties of boulders are consistent with moderately dehydrated materials, analogous to thermally metamorphosed meteorites found on Earth. The general uniformity in color across Ryugu's surface supports partial dehydration due to internal heating of the asteroid's parent body.
Collapse
|
23
|
Abstract OT2-01-02: Thoracic interfascial nerve blocks versus paravertebral block for improving quality of recovery after breast cancer surgery: A randomized, double-blind, non-inferiority trial. Cancer Res 2019. [DOI: 10.1158/1538-7445.sabcs18-ot2-01-02] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Abstract
Background: Chronic pain after breast cancer surgeryhas harmful effects on patients' daily life. Paravertebral block (PVB) can prevent not only acute but chronic pain after breast cancer surgery, although the block is not easily put into practice because of technical difficulty or necessity to change patients' position. Thoracic interfascial nerve blocks (TINB) have been reported that it gives similar analgesic efficacy as PVB as with fewer risks, however there are no reports comparing analgesic efficacy of PVB with TINB. Although there are several scales evaluating postoperative pain including visual analog scale (VAS) or numerical rating scale, Quality of Recovery (QoR) have been set up to assess the impact of postoperative morbidity on patients' ability to return to normal function and quality of life. Among those assessment scales, QoR-40 has been mainly applied. It consists of 40 questions including five dimensions: psychologic support, physical comfort, emotional state, physical independence, and pain. There is a report suggesting that PVB improve QoR-40 after ambulatory breast tumor resection.
Methods: This is a single center single arm phase 2 study for early breast cancer patients. Exclusion criteria are pregnant and parturient women, allergy to local anesthetics, significant psychiatric or mental disorders, and patients with chronic pain. All blocks are subjected to ultrasound guidance. Patients were randomized to receive PVB with 40 ml ropivacaine or TINB with 60 ml ropivacaine. TINB consisted of modified PECS II block and transversus thoracic muscle plane block. For assessment of QoR, QoR-40 score which was consisted of 5 elements including postoperative pain was used. The trial was activated in July 2016.
Statistical Method: We conducted a pilot study on 16 patients who received a PVB during breast cancer surgery. Based on the standard deviation (SD) of QoR-40 on postoperative day (POD) 1, the SD was set to 7.2. Since the non-inferiority limit needs to be reduced to about half as much as the effect quantity used in the average value superiority test, it is set to 8, which is half of the effect quantity 16 in the pilot study. When one-sided test with α error = 0.025 and β error = 0.2, about 13 cases in each group are required. Given that dropout rate is about 30-40%, 18 cases in each group were taken as the number of subject cases.
Results: Thirty-six patients were accrual, 18 of PVB group and 18 of TINB group. Two patients declined the trial, 36/38 (95%) acceptors completed the trial. Total of QoR-40 scores on POD 1 was designated as the primary outcome. For secondary outcomes, both QoR-40 score and pain score were assessed on POD 3 and in postoperative month(s) 1, 3, 6, 12. Other secondary outcomes included pain score by POD 1, incidence of rescue analgesia, time to rescue analgesia, incidence of nausea and vomiting. All patients provided written informed consent before undergoing any study-related procedures.
Conclusions: This trial will provide non-inferiority that TINB preserve the effect of QoR as good as PVB after breast cancer surgery.
If interested, please contact T Horiuchi at t_horiuchi@seichokai.or.jp.
Clinical trial information: UMIN000023340
Citation Format: Abe H, Horiuchi T, Teramoto A, Tanaka Y, Takei Y, Nagahata T. Thoracic interfascial nerve blocks versus paravertebral block for improving quality of recovery after breast cancer surgery: A randomized, double-blind, non-inferiority trial [abstract]. In: Proceedings of the 2018 San Antonio Breast Cancer Symposium; 2018 Dec 4-8; San Antonio, TX. Philadelphia (PA): AACR; Cancer Res 2019;79(4 Suppl):Abstract nr OT2-01-02.
Collapse
|
24
|
Simultaneous measurement of patient dose and distribution of indoor scattered radiation during digital breast tomosynthesis. Radiography (Lond) 2019; 25:72-76. [PMID: 30599834 DOI: 10.1016/j.radi.2018.10.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2018] [Revised: 10/22/2018] [Accepted: 10/23/2018] [Indexed: 10/27/2022]
Abstract
INTRODUCTION Breast cancer incidence increases from the age of 30 years. As this age range coincides with that in which women usually pursue pregnancy, undergoing medical examinations for conditions such as breast cancer is a concern, especially when pregnancy is uncertain during the first eight weeks. Moreover, in this age range, breast often exhibits a high density, thus compromising diagnosis. For such density, digital breast tomosynthesis (DBT) provides a more accurate diagnosis than 2D mammography given its higher sensitivity and specificity. However, radiation exposure increases during DBT, and it should be determined. METHODS We determined the entrance surface dose, scattered radiation dose, and average glandular dose (AGD), which can be mutually compared following an international protocol. Using our proposed method, the distribution of scattered radiation can be easily and quickly obtained with a minor load to the equipment. Then, we can determine the indoor scattered radiation and surface dose on patients during DBT. RESULTS We obtained a maximum AGD of 2.32 mGy. The scattered radiation was distributed over both sides with maximum of approximately 40 μGy, whereas the maximum dose around the eye was approximately 10 μGy. CONCLUSION By measuring doses using the proposed method, a correct dose information can be provided for patients to mitigate their concerns about radiation exposure. Although the obtained doses were low, their proper management is still required. Overall, the results from this study can help to enhance dose management for patients and safety management regarding indoor radiation.
Collapse
|
25
|
[AOCMP2018]. IGAKU BUTSURI : NIHON IGAKU BUTSURI GAKKAI KIKANSHI = JAPANESE JOURNAL OF MEDICAL PHYSICS : AN OFFICIAL JOURNAL OF JAPAN SOCIETY OF MEDICAL PHYSICS 2019; 38:182-183. [PMID: 30828053 DOI: 10.11323/jjmp.38.4_182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
|
26
|
P1680The impact of statin therapy in the patients with vasospastic angina: multicenter registry study of the Japanese coronary spasm association. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy565.p1680] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
27
|
5971Predictors of the results of the confirmatory tests for the diagnosis of primary hyperaldosteronism in hypertensive patients with an aldosterone-to-renin ratio greater than 20. Eur Heart J 2018. [DOI: 10.1093/eurheartj/ehy566.5971] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
28
|
Gastrointestinal: Gastric inflammatory fibroid polyp that was resected after a 10-year follow-up. J Gastroenterol Hepatol 2018; 33:5. [PMID: 28768372 DOI: 10.1111/jgh.13913] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/09/2022]
|
29
|
Transforming growth factor-β1 levels in the cerebrospinal fluid of patients with neurodegenerative diseases. J Neurol Sci 2017. [DOI: 10.1016/j.jns.2017.08.868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
30
|
Horizontal rectal transection using an endolinear stapler for laparoscopic low anterior resection. Tech Coloproctol 2017; 21:311-313. [DOI: 10.1007/s10151-017-1617-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2016] [Accepted: 04/03/2017] [Indexed: 10/19/2022]
|
31
|
Effects of arachidonic acid on FFA4 receptor: Signaling, phosphorylation and internalization. Prostaglandins Leukot Essent Fatty Acids 2017; 117:1-10. [PMID: 28237082 DOI: 10.1016/j.plefa.2017.01.013] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/22/2016] [Revised: 11/28/2016] [Accepted: 01/24/2017] [Indexed: 12/18/2022]
Abstract
Arachidonic acid increased intracellular calcium, in cells expressing green fluorescent protein-tagged human FFA4 receptors, with an EC50 of ~40µM. This action was not blocked by cyclooxygenase or lipoxigenase inhibitors but it was inhibited by AH7614, a FFA4 antagonist. Arachidonic acid induced ERK activation accompanied by EGF receptor transactivation. However, EGF transactivation was not the major mechanism through which the fatty acid induced ERK phosphorylation, as evidenced by the inability of AG1478 to block it. Arachidonic acid increased FFA4 receptor phosphorylation that reached its maximum within 15min with an EC50 of ~30µM; inhibitors of protein kinase C partially diminish this effect and AH7614 blocked it. Arachidonic acid induced rapid and sustained Akt/PKB phosphorylation and FFA4 - β-arrestin interaction. Confocal microscopy evidenced that FFA4 receptor activation and phosphorylation were associated to internalization. In conclusion, arachidonic acid is a bona fide FFA4 receptor agonist.
Collapse
|
32
|
Discontinuation of Hepatitis B Immunoglobulin by Long-term Hepatitis B Vaccine Inoculation in Preventing Hepatitis B Recurrence After Liver Transplantation. Transplant Proc 2017; 48:1179-83. [PMID: 27320582 DOI: 10.1016/j.transproceed.2015.12.110] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2015] [Accepted: 12/30/2015] [Indexed: 12/13/2022]
Abstract
INTRODUCTION For the patients undergoing liver transplantation for hepatitis B virus (HBV)-related diseases, hepatitis B immunoglobulin (HBIG) should be administered to prevent reinfection. Because HBIG is highly expensive and a blood product, an alternative strategy using HBV vaccination has been made in an attempt to discontinue use of HBIG. The aim of this study was to evaluate the impact of long-term HBV vaccination for discontinuation of HBIG, paying attention to the status of active immunization using T-cell proliferation assay. PATIENTS AND METHODS Among the 144 recipients who underwent liver transplantation in our hospital, 16 had HBV-related liver diseases; the 14 patients who had received vaccination were subjects in our study. To evaluate the status of active immunization, T-cell proliferation was examined by counting the number of T cells after adding HBV vaccine to the culture supernatant of T cells, and tumor necrosis factor α and interferon γ were measured in the culture supernatant. RESULTS The ratio of male/female was 13/1 (median age: 55 years; range: 37 years to 67 years). The median follow-up time was 102 months (range: approximately 14 months to 148 months). All 14 patients were free of HBV recurrence. HBIG-free status could be achieved in 9 patients (64.3%) during the treatment period for more than 50 months after beginning of HBV vaccination, of whom 5 (35.7%) became HBV vaccine-free. T-cell proliferation was confirmed by fact that the stimulation index ranged from 2.34 to 5.2 in the patients who were HBIG-free. CONCLUSION Long-term HBV vaccination after LT is a useful and effective treatment in preventing HBV recurrence, allowing the discontinuation of HBIG treatment.
Collapse
|
33
|
Calibration of the microcalorimeter spectrometer on-board the Hitomi (Astro-H) observatory (invited). THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:11D503. [PMID: 27910640 DOI: 10.1063/1.4961075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
The Hitomi Soft X-ray Spectrometer (SXS) was a pioneering non-dispersive imaging x-ray spectrometer with 5 eV FWHM energy resolution, consisting of an array of 36 silicon-thermistor microcalorimeters at the focus of a high-throughput soft x-ray telescope. The instrument enabled astrophysical plasma diagnostics in the 0.3-12 keV band. We introduce the SXS calibration strategy and corresponding ground calibration measurements that took place from 2012-2015, including both the characterization of the microcalorimeter array and measurements of the x-ray transmission of optical blocking filters.
Collapse
|
34
|
Abstract
In an experiment with the BigRIPS separator at the RIKEN Nishina Center, we observed two-proton (2p) emission from ^{67}Kr. At the same time, no evidence for 2p emission of ^{59}Ge and ^{63}Se, two other potential candidates for this exotic radioactivity, could be observed. This observation is in line with Q value predictions which pointed to ^{67}Kr as being the best new candidate among the three for two-proton radioactivity. ^{67}Kr is only the fourth 2p ground-state emitter to be observed with a half-life of the order of a few milliseconds. The decay energy was determined to be 1690(17) keV, the 2p emission branching ratio is 37(14)%, and the half-life of ^{67}Kr is 7.4(30) ms.
Collapse
|
35
|
Three-Dimensional Display of Liver, Spleen, Hepatoma, and Blood Vessels by MR Imaging and Computer Graphics. Acta Radiol 2016. [DOI: 10.1177/028418519403500118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The technique of generating 3-D images from CT and MR data has made progress. Manipulation of the images has become simpler, the processing time shorter, and the quality better. Clinical application of this technique has been performed for images of brain (5, 7, 8) and bone (1, 2, 6), but only a few studies have been done of abdominal organs (3, 4).
Collapse
|
36
|
Abstract
UNLABELLED Essentials Epithelial cell apoptosis is critical in the pathogenesis of idiopathic pulmonary fibrosis. Protein S, a circulating anticoagulant, inhibited apoptosis of lung epithelial cells. Overexpression of protein S in lung cells reduced bleomycin-induced pulmonary fibrosis. Intranasal therapy with exogenous protein S ameliorated bleomycin-induced pulmonary fibrosis. SUMMARY Background Pulmonary fibrosis is the terminal stage of interstitial lung diseases, some of them being incurable and of unknown etiology. Apoptosis plays a critical role in lung fibrogenesis. Protein S is a plasma anticoagulant with potent antiapoptotic activity. The role of protein S in pulmonary fibrosis is unknown. Objectives To evaluate the clinical relevance of protein S and its protective role in pulmonary fibrosis. Methods and Results The circulating level of protein S was measured in patients with pulmonary fibrosis and controls by the use of enzyme immunoassays. Pulmonary fibrosis was induced with bleomycin in transgenic mice overexpressing human protein S and wild-type mice, and exogenous protein S or vehicle was administered to wild-type mice; fibrosis was then compared in both models. Patients with pulmonary fibrosis had reduced circulating levels of protein S as compared with controls. Inflammatory changes, the levels of profibrotic cytokines, fibrosis score, hydroxyproline content in the lungs and oxygen desaturation were significantly reduced in protein S-transgenic mice as compared with wild-type mice. Wild-type mice treated with exogenous protein S showed significant decreases in the levels of inflammatory and profibrotic markers and fibrosis in the lungs as compared with untreated control mice. After bleomycin infusion, mice overexpressing human protein S showed significantly low caspase-3 activity, enhanced expression of antiapoptotic molecules and enhanced Akt and Axl kinase phosphorylation as compared with wild-type counterparts. Protein S also inhibited apoptosis of alveolar epithelial cells in vitro. Conclusions These observations suggest clinical relevance and a protective role of protein S in pulmonary fibrosis.
Collapse
|
37
|
Cytokine-related and sodium channel polymorphism as candidate predisposing factors for childhood encephalopathy FIRES/AERRPS. J Neurol Sci 2016; 368:272-6. [PMID: 27538648 DOI: 10.1016/j.jns.2016.07.040] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2016] [Revised: 07/13/2016] [Accepted: 07/14/2016] [Indexed: 11/15/2022]
Abstract
Febrile infection-related epilepsy syndrome (FIRES), or acute encephalitis with refractory, repetitive partial seizures (AERRPS), is an epileptic encephalopathy beginning with fever-mediated seizures. The etiology remains unclear. To elucidate the genetic background of FIRES/AERRPS (hereafter FIRES), we recruited 19 Japanese patients, genotyped polymorphisms of the IL1B, IL6, IL10, TNFA, IL1RN, SCN1A and SCN2A genes, and compared their frequency between the patients and controls. For IL1RN, the frequency of a variable number of tandem repeat (VNTR) allele, RN2, was significantly higher in the patients than in controls (p=0.0067), and A allele at rs4251981 in 5' upstream of IL1RN with borderline significance (p=0.015). Haplotype containing RN2 was associated with an increased risk of FIRES (OR 3.88, 95%CI 1.40-10.8, p=0.0057). For SCN1A, no polymorphisms showed a significant association, whereas a missense mutation, R1575C, was found in two patients. For SCN2A, the minor allele frequency of G allele at rs1864885 was higher in patients with borderline significance (p=0.011). We demonstrated the association of IL1RN haplotype containing RN2 with FIRES, and showed a possible association of IL1RN rs4251981 G>A and SCN2A rs1864885 A>G, in Japanese patients. These preliminary findings suggest the involvement of multiple genetic factors in FIRES, which needs to be confirmed by future studies in a larger number of FIRES cases.
Collapse
|
38
|
Development of high-order harmonic focusing system based on ellipsoidal mirror. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2016; 87:051803. [PMID: 27250370 DOI: 10.1063/1.4950735] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/11/2015] [Accepted: 03/11/2016] [Indexed: 06/05/2023]
Abstract
We have developed a focusing system for extreme ultraviolet light produced by high-order harmonic generation. An ellipsoidal mirror with a precise surface shape was fabricated and installed into the focusing system. A rigid mirror manipulator and a beam profiler were employed to perform precise and stable mirror alignment. As a demonstration of the focusing performance, high-order harmonics in the wavelength range of 13.5-19.5 nm were successfully focused into a 2.4 × 2.3 μm(2) spot.
Collapse
|
39
|
Circulating fibrocytes correlate with the asthma control test score. Allergol Immunopathol (Madr) 2016; 44:191-6. [PMID: 26774356 DOI: 10.1016/j.aller.2015.09.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2015] [Revised: 09/05/2015] [Accepted: 09/30/2015] [Indexed: 11/29/2022]
Abstract
BACKGROUND Bronchial asthma is characterised by airway inflammation and remodelling with a decline of lung function. Fibrocytes are bone marrow-derived mesenchymal progenitor cells that play important roles in the pathogenesis of airway remodelling. Several clinical parameters are currently being used in routine clinical practice to assess outcome of therapy in asthma including frequency of rescue with short-acting β2-agonist and the asthma control test. In this study, we hypothesised that asthma control test is associated with circulating levels of fibrocytes in bronchial asthma. METHODS There were 20 patients with asthma and seven healthy controls. The number of CD45(+)Collagen I(+) circulating fibrocytes was assessed in the peripheral blood by flow cytometry. RESULTS The number of circulating fibrocytes was significantly increased in asthma patients with moderate and severe disease compared to controls, and it was inversely correlated with % forced expiratory volume in one second and % forced vital capacity (%FVC). The frequency of inhalation of short-acting β2 agonist and the asthma control test score was significantly and inversely correlated with the number of circulating fibrocytes. CONCLUSION The results of this study showed that the number of circulating fibrocytes is inversely correlated with clinical asthma control parameters, further supporting the relevance of measuring circulating fibrocytes as a marker of clinical control in bronchial asthma.
Collapse
|
40
|
Re: Abnormally invasive placenta - prevalence, risk factors and antenatal suspicion: results from a large population-based pregnancy cohort study in the Nordic countries. BJOG 2016; 123:1031-2. [DOI: 10.1111/1471-0528.13759] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/22/2015] [Indexed: 11/30/2022]
|
41
|
Expression of p53 synergistically augments caspases-mediated apoptosis induced by replication-competent adenoviruses in pancreatic carcinoma cells. Cancer Gene Ther 2015; 22:445-53. [DOI: 10.1038/cgt.2015.33] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2014] [Revised: 07/02/2015] [Accepted: 07/03/2015] [Indexed: 12/16/2022]
|
42
|
Biliary complications in 108 consecutive recipients with duct-to-duct biliary reconstruction in living-donor liver transplantation. Transplant Proc 2015; 46:850-5. [PMID: 24767364 DOI: 10.1016/j.transproceed.2013.11.035] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2013] [Accepted: 11/05/2013] [Indexed: 12/19/2022]
Abstract
BACKGROUND Biliary complications remain the leading cause of postoperative complications after living-donor liver transplantation (LDLT) in patients undergoing duct-to-duct choledochocholedochostomy. The aim of this study was to analyze the causes of these complications. METHODS One hundred eight patients who underwent LDLT with duct-to-duct biliary reconstruction at Mie University Hospital were enrolled in this study. The mean follow-up time was 58.4 months (range, 3-132). The most recent 18 donors underwent indocyanine green (ICG) fluorescence cholangiography for donor hepatectomy. The development of biliary complications was retrospectively analyzed. Biliary complications were defined as needing endoscopic or radiologic treatment. RESULTS Biliary leakages and strictures occurred in 6 (5.6%) and 15 (13.9%) of the recipients, respectively, and 3 donors (2.7%) experienced biliary leakage. However, since the introduction of ICG fluorescence cholangiography, we have not encountered any biliary complications in either donors or recipients. Biliary leakage was an independent risk factor for the development of biliary stricture (P = .013). Twelve (80%) of the 15 recipients with biliary stricture had successful nonoperative endoscopic or radiologic management, and 3 patients underwent surgical repair with hepaticojejunosotomy. CONCLUSIONS Biliary leakage was an independent factor for biliary stricture. ICG fluorescence cholangiography might be helpful to reduce biliary complications after LDLT in both donors and recipients.
Collapse
|
43
|
Protein S exacerbates alcoholic hepatitis by stimulating liver natural killer T cells. J Thromb Haemost 2015; 13:142-54. [PMID: 25399514 DOI: 10.1111/jth.12789] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2014] [Accepted: 11/05/2014] [Indexed: 12/15/2022]
Abstract
BACKGROUND Alcohol consumption is a major cause of liver injury but the mechanisms are not completely understood. Protein S (PS) is an anticoagulant glycoprotein with multiple functions. The role of PS in liver injury is unknown. OBJECTIVES This study investigated the role of PS in acute alcoholic hepatitis. METHODS A mouse overexpressing human PS (hPS-TG) was generated in which acute hepatitis was induced by intraperitoneal injection of ethanol. RESULTS The levels of serum liver enzymes and liver tissue inflammatory cytokines and the degree of hepatic steatosis were significantly increased in hPS-TG mice treated with ethanol compared with ethanol-treated wild type (WT) mice. Cell expansion, activation and inhibition of apoptosis were significantly augmented in natural killer T (NKT) cells from hPS-TG mice compared with WT mice. Liver mononuclear cells from hPS-TG mice express higher levels of inflammatory cytokines than those from WT mice after stimulation with a specific stimulant of NKT cells in vitro. In a co-culture system of hepatocytes and NKT cells, the effects of PS on ethanol-mediated cell injury were suppressed by a CD1d neutralizing antibody. Alcoholic liver injury was significantly improved in mice pre-treated with PS siRNA and anti-protein S antibody compared with control mice. Patients with alcoholic hepatitis showed significantly increased plasma PS levels and enhanced liver expression of PS and CD1d compared with controls. CONCLUSIONS The results of this study suggest that PS exacerbates acute alcoholic hepatitis by inhibiting apoptosis of activated NKT cells.
Collapse
MESH Headings
- Animals
- Antibodies, Neutralizing/pharmacology
- Antigens, CD1d/immunology
- Antigens, CD1d/metabolism
- Apoptosis
- Blood Proteins/genetics
- Blood Proteins/metabolism
- Case-Control Studies
- Cells, Cultured
- Coculture Techniques
- Disease Models, Animal
- Ethanol
- Fatty Liver, Alcoholic/immunology
- Fatty Liver, Alcoholic/metabolism
- Fatty Liver, Alcoholic/pathology
- Hepatitis, Alcoholic/genetics
- Hepatitis, Alcoholic/immunology
- Hepatitis, Alcoholic/metabolism
- Hepatitis, Alcoholic/pathology
- Hepatitis, Alcoholic/prevention & control
- Hepatocytes/immunology
- Hepatocytes/metabolism
- Hepatocytes/pathology
- Humans
- Inflammation Mediators/immunology
- Inflammation Mediators/metabolism
- Liver/immunology
- Liver/metabolism
- Liver/pathology
- Lymphocyte Activation
- Male
- Mice, Inbred C57BL
- Mice, Transgenic
- Natural Killer T-Cells/immunology
- Natural Killer T-Cells/metabolism
- Protein S/genetics
- Protein S/metabolism
- RNAi Therapeutics
- Severity of Illness Index
- Signal Transduction
- Up-Regulation
Collapse
|
44
|
CsBr:Eu Phosphor Ceramics as a New Photostimulable Phosphor Material for Two Dimensional X-ray Imaging Sensor. J NUCL SCI TECHNOL 2014. [DOI: 10.1080/00223131.2004.10875722] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
45
|
Analysis of the effect of adjuvant radiotherapy on outcome and complications after radical hysterectomy in FIGO stage IB1 cervical cancer patients with intermediate risk factors. Gynecol Oncol 2014. [DOI: 10.1016/j.ygyno.2014.03.167] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
46
|
Acoustic characteristics of voluntary expiratory sounds after swallow for detecting dysphagia. J Oral Rehabil 2014; 41:667-74. [DOI: 10.1111/joor.12184] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/15/2014] [Indexed: 11/28/2022]
|
47
|
Negative Prognostic Impact of Renal Replacement Therapy in Adult Living-donor Liver Transplant Recipients: Preoperative Recipient Condition and Donor Factors. Transplant Proc 2014; 46:716-20. [DOI: 10.1016/j.transproceed.2013.11.113] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2013] [Accepted: 11/15/2013] [Indexed: 02/07/2023]
|
48
|
Severe obstructive sleep apnea increases left atrial volume independent of left ventricular diastolic impairment. Eur Heart J 2013. [DOI: 10.1093/eurheartj/eht308.p1119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
49
|
Prognostic significance of coronary flow reserve during acute hyperglycemia. Eur Heart J 2013. [DOI: 10.1093/eurheartj/eht311.5925] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
50
|
Angioscopic characteristics of neoatherosclerosis in coronary dug-eluting stents: comparison between the first and second generations. Eur Heart J 2013. [DOI: 10.1093/eurheartj/eht309.p3926] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|