1
|
Incorporation of Three Different Optical Trains into the IR-MALDESI Mass Spectrometry Imaging Platform to Characterize Artemisia annua. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024. [PMID: 38686539 DOI: 10.1021/jasms.4c00060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/02/2024]
Abstract
Artemisinin is the leading medication for the treatment of malaria and is only produced naturally in Artemisia annua. The localization of artemisinin in both the glandular and non-glandular trichomes of the plant makes it an ideal candidate for mass spectrometry imaging (MSI) as a model system for method development. Infrared matrix-assisted laser desorption electrospray ionization MSI (IR-MALDESI-MSI) has the capability to detect hundreds to thousands of analytes simultaneously, providing abundance information in conjunction with species localization throughout a sample. The development of several new optical trains and their application to the IR-MALDESI-MSI platform has improved data quality in previous proof-of-concept experiments but has not yet been applied to analysis of native biological samples, especially the MSI analysis of plants. This study aimed to develop a workflow and optimize MSI parameters, specifically the laser optical train, for the analysis of Artemisia annua with the NextGen IR-MALDESI platform coupled to an Orbitrap Exploris 240 mass spectrometer. Two laser optics were compared to the conventional set up, of which include a Schwarzschild-like reflective objective and a diffractive optical element (DOE). These optics, respectively, enhance the spatial resolution of imaging experiments or create a square spot shape for top-hat imaging. Ultimately, we incorporated and characterized three different optical trains into our analysis of Artemisia annua to study metabolites in the artemisinin pathway. These improvements in our workflow, resulted in high spatial resolution and improved ion abundance from previous work, which will allow us to address many different questions in plant biology beyond this model system.
Collapse
|
2
|
Achieving Cross-Ring Fragmentation of N-Linked Glycans by IR-MALDESI. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:166-171. [PMID: 38113534 DOI: 10.1021/jasms.3c00283] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/21/2023]
Abstract
Glycans are complex structures that require MS/MS for detailed structural elucidation. Incorporating metals can provide more structural information by inhibiting glycosidic cleavage and enhancing cross-ring fragmentation. A direct analysis was performed using lithium doping and IR-MALDESI to induce cross-ring fragmentation of glycans. The protonated and lithiated versions of the two glycans were isolated and subjected to HCD. For protonated glycans, only glycosidic cleavages were observed. Using lithium doping, MS/MS consisted of abundant cross-ring fragments. Seventeen cross-ring fragments were detected across both glycans using lithium-doped ESI. This is the first incorporation of metal doping in IR-MALDESI to achieve cross-ring fragments in MS/MS analysis.
Collapse
|
3
|
Comparative analysis of sucrose-embedding for whole-body zebrafish MSI by IR-MALDESI. Anal Bioanal Chem 2023; 415:6389-6398. [PMID: 37640826 DOI: 10.1007/s00216-023-04914-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Revised: 08/13/2023] [Accepted: 08/15/2023] [Indexed: 08/31/2023]
Abstract
Infrared matrix-assisted laser desorption electrospray ionization mass spectrometry imaging (IR-MALDESI) conventionally utilizes fresh-frozen biological tissues with an ice matrix to improve the detection of analytes. Sucrose-embedding with paraformaldehyde fixation has demonstrated feasibility as an alternative matrix for analysis by IR-MALDESI by preserving tissue features and enhancing ionization of lipids. However, investigating multi-organ systems provides broader context for a biological study and can elucidate more information about a disease state as opposed to a single organ. Danio rerio, or zebrafish, are model organisms for various disease states and can be imaged as a multi-organ sample to analyze morphological and metabolomic preservation as a result of sample preparation. Herein, whole-body zebrafish were imaged to compare sucrose-embedding with paraformaldehyde fixation against conventional fresh-frozen sample preparation. Serial sections were analyzed with and without an ice matrix to evaluate if sucrose functions as an alternative energy-absorbing matrix for IR-MALDESI applications across whole-body tissues. The resulting four conditions were compared in terms of total putative lipid annotations and category diversity, coverage across the entire m/z range, and ion abundance. Ultimately, sucrose-embedded zebrafish had an increase in putative lipid annotations for the combination of putative annotations with and without the application of an ice matrix relative to fresh-frozen tissues which require the application of an ice matrix. Upon the use of an ice matrix, a greater number of high mass putative lipid annotations (e.g., glycerophospholipids, glycerolipids, and sphingolipids) were identified. Conversely, without an ice matrix, sucrose-embedded sections elucidated more putative annotations in lower molecular weight lipids, including fatty acyls and sterol lipids. Similar to the mouse brain model, sucrose-embedding increased putative lipid annotation and abundance for whole-body zebrafish.
Collapse
|
4
|
Metabolite Annotation Confidence Score (MACS): A Novel MSI Identification Scoring Tool. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:2222-2231. [PMID: 37606933 DOI: 10.1021/jasms.3c00178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/23/2023]
Abstract
Mass spectrometry imaging (MSI) is an analytical technique capable of measuring and visualizing the spatial distribution of thousands of ions across a sample. Measured ions can be putatively identified and annotated by comparing their mass-to-charge ratio (m/z) to a database of known compounds. For high-resolution, accurate mass (HRAM) imaging data sets, this is commonly performed by the annotation platform METASPACE. Annotations are reported with a metabolite-signal-match (MSM) score as a measure of the annotation's confidence level. However, the MSM scores reported by METASPACE often do not reflect a reasonable confidence level of an annotation and are not assigned consistently. The metabolite annotation confidence score (MACS) is an alternative scoring system based on fundamental mass spectrometry imaging metrics (mass measurement accuracy, spectral accuracy, and spatial distribution) to generate values that reflect the confidence of a specific annotation in HRAM-MSI data sets. Herein, the MACS system is characterized and compared to MSM scores from ions annotated by METASPACE.
Collapse
|
5
|
Maximized Spatial Information and Minimized Acquisition Time of Top-Hat IR-MALDESI-MSI of Zebrafish Using Nested Regions of Interest (nROIs). JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:2043-2050. [PMID: 37526449 DOI: 10.1021/jasms.3c00210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/02/2023]
Abstract
Increasing the spatial resolution of a mass spectrometry imaging (MSI) method results in a more defined heatmap of the spatial distribution of molecules across a sample, but it is also associated with the disadvantage of increased acquisition time. Decreasing the area of the region of interest to achieve shorter durations results in the loss of potentially valuable information in larger specimens. This work presents a novel MSI method to reduce the time of MSI data acquisition with variable step size imaging: nested regions of interest (nROIs). Using nROIs, a small ROI may be imaged at a higher spatial resolution while nested inside a lower-spatial-resolution peripheral ROI. This conserves the maximal spatial and chemical information generated from target regions while also decreasing the necessary acquisition time. In this work, the nROI method was characterized on mouse liver and applied to top-hat MSI of zebrafish using a novel optical train, which resulted in a significant improvement in both acquisition time and spatial detail of the zebrafish. The nROI method can be employed with any step size pairing and adapted to any method in which the acquisition time of larger high-resolution ROIs poses a practical challenge.
Collapse
|
6
|
Automatic z-Axis Correction for IR-MALDESI Mass Spectrometry Imaging of Uneven Surfaces. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023. [PMID: 37306946 DOI: 10.1021/jasms.3c00151] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Two-dimensional mass spectrometry imaging (2D MSI) experiments mainly involve samples with a flat surface and constant thickness, but some samples are challenging to section due to the texture and topography. Herein, we present an MSI method that automatically corrects for discernible height differences across surfaces during imaging experiments. A chromatic confocal sensor was incorporated into the infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) system to measure the sample surface height at the location of each analytical scan. The height profile is subsequently used for adjusting the z-axis position of the sample during MSI data acquisition. We evaluated this method using a tilted mouse liver section and an unsectioned Prilosec tablet due to their exterior quasi-homogeneity and height differences of approximately ∼250 μm. MSI with automatic z-axis correction showed consistent ablated spot sizes and shapes, revealing the measured ion spatial distribution across a mouse liver section and a Prilosec tablet. Conversely, irregular spots and reduced signals with large variability were observed when no z-axis correction was applied.
Collapse
|
7
|
Predicting Sialic Acid Content of N-Linked Glycans Using the Isotopic Pattern of Chlorine. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023. [PMID: 37289618 DOI: 10.1021/jasms.3c00100] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Sialic acids play several roles in both physiological and pathological processes; however, due to their labile nature, they are difficult to analyze using mass spectrometry. Previous work has shown that infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) is able to detect intact sialylated N-linked glycans without the use of chemical derivatization. In this work, we describe a new rule that can predict the number of sialic acids on a glycan. Formalin-fixed paraffin-embedded human kidney tissue was prepared using previously established methods and analyzed using IR-MALDESI in negative-ion mode mass spectrometry. Using the experimental isotopic distribution of a detected glycan, we can predict the number of sialic acids on the glycan; #sialic acids is equal to the charge state minus the number of chlorine adducts, or z - #Cl-. This new rule grants confident glycan annotations and compositions beyond accurate mass measurements, thereby further improving the capability of IR-MALDESI to study sialylated N-linked glycans within biological tissues.
Collapse
|
8
|
Development of an object-based image analysis tool for mass spectrometry imaging ion classification. Anal Bioanal Chem 2023:10.1007/s00216-023-04764-x. [PMID: 37222794 DOI: 10.1007/s00216-023-04764-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2023] [Revised: 05/10/2023] [Accepted: 05/15/2023] [Indexed: 05/25/2023]
Abstract
Mass spectrometry imaging (MSI) is an analytical technique that can detect and visualize thousands of m/z values resolved in two- and three-dimensional space. These m/z values lead to hundreds of molecular annotations, including on-tissue and background ions. Discrimination of sample-related analytes from ambient ions conventionally involves manual investigation of each ion heatmap, which requires significant researcher time and effort (for a single tissue image, it can take an hour to determine on-tissue and off-tissue species). Moreover, manual investigation lends itself to subjectivity. Herein, we present the utility of an ion classification tool (ICT) developed using object-based image analysis in MATLAB. The ICT functions by segmenting ion heatmap images into on-tissue and off-tissue objects through binary conversion. The binary images are analyzed and within seconds used to classify the ions as on-tissue or background using a binning approach based on the number of detected objects. In a representative dataset with 50 randomly selected annotations, the ICT was able to accurately classify 45/50 ions as on-tissue or background.
Collapse
|
9
|
Lipidomic Analysis of Mouse Brain to Evaluate the Efficacy and Preservation of Different Tissue Preparatory Techniques by IR-MALDESI-MSI. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:869-877. [PMID: 36988291 DOI: 10.1021/jasms.2c00353] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Numerous preparatory methods have been developed to preserve the cellular and structural integrity of various biological tissues for different -omics studies. Herein, two preparatory methods for mass spectrometry imaging (MSI) were evaluated, fresh-frozen and sucrose-embedded, paraformaldehyde (PFA) fixed, in terms of ion abundance, putative lipid identifications, and preservation of analyte spatial distributions. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI)-MSI was utilized to compare the preparatory methods of interest with and without the use of the conventional ice matrix. There were 2.5-fold and 1.6-fold more lipid species putatively identified in positive- and negative-ion modes, respectively, for sucrose-embedded, PFA-fixed tissues without an ice matrix relative to the current IR-MALDESI-MSI gold-standard, fresh-frozen tissue preparation with an exogenous ice matrix. Furthermore, sucrose-embedded tissues demonstrated improved spatial distribution of ions resulting from the cryo-protective property of sucrose and paraformaldehyde fixation. Evidence from these investigations supports sucrose-embedding without ice matrix as an alternative preparatory technique for IR-MALDESI-MSI.
Collapse
|
10
|
Achieving Sub-Parts-per-Million Mass Measurement Accuracy on an Orbitrap Mass Spectrometry Imaging Platform without Automatic Gain Control. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023. [PMID: 37096916 DOI: 10.1021/jasms.3c00004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
The collection of profile data is standard practice within the field of mass spectrometry (MS). However, profile data collection often results in large data files that require extensive processing times, especially in mass spectrometry imaging (MSI) studies where thousands of high-resolution scans are recorded. Natively collecting centroid MS data is an alternative that effectively reduces both the resulting file size and the data processing time. Herein, high-resolution accurate mass (HRAM) Orbitrap MSI data on mouse liver tissue sections without automatic gain control (AGC) were natively collected in both profile and centroid modes and compared based on the file size and processing time. Additionally, centroid data were evaluated against the profile data with regard to the spectra integrity, mass measurement accuracy (MMA), and the number of lipid annotations to ensure that centroid data did not compromise the data quality. For both native and postacquisition centroided data, the variation in mass measurement accuracy decreased relative to the profile data collection. Furthermore, centroid data collection increased the number of METASPACE database annotations indicating higher sensitivity and greater accuracy for lipid annotation compared to native profile data collection. Profile MSI data was shown to have a higher likelihood of false positive identifications due to an increased number of data points on either side of the peaks, whereas the same trend was not observed in data collected in native centroid data collection. This publication explores and explains the importance in properly centroiding MSI data, either natively or by adequate centroiding methods, to obtain the most accurate information and come to the best conclusions. These data support that natively collecting centroid data significantly improves MMA to sub-ppm levels without AGC and reduces false positive annotations.
Collapse
|
11
|
Transforming a Mid-infrared Laser Profile from Gaussian to a Top-Hat with a Diffractive Optical Element for Mass Spectrometry Imaging. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2023; 34:10-16. [PMID: 36542595 PMCID: PMC9975536 DOI: 10.1021/jasms.2c00203] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Many mass spectrometry imaging (MSI) applications such as infrared matrix-assisted electrospray ionization (IR-MALDESI) employ an infrared (IR) laser with a Gaussian profile where laser irradiance is highest in the center and decreases exponentially. To enable full ablation of a square region of interest, oversampling is often needed, which results in nonuniform ablation and leads to decreased image quality. A diffractive optical element (DOE) was integrated into the optical path to generate homogeneous intensity distributions while maintaining laser energy above the ablation threshold, to enable complete sample removal from laser pulses without oversampling. 2D and 3D imaging with the DOE inserted show clear and sharp ablation patterns with satisfactory biological signals gained. Further improvements will optimize the beam profile and generate a square top-hat laser beam for MSI application at higher spatial resolution.
Collapse
|
12
|
Quasi-continuous infrared matrix-assisted laser desorption electrospray ionization source coupled to a quadrupole time-of-flight mass spectrometer for direct analysis from well plates. JOURNAL OF MASS SPECTROMETRY : JMS 2023; 58:e4902. [PMID: 36694312 PMCID: PMC9944147 DOI: 10.1002/jms.4902] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/17/2022] [Revised: 12/03/2022] [Accepted: 01/07/2023] [Indexed: 06/17/2023]
Abstract
High-throughput screening (HTS) is a technique mostly used by pharmaceutical companies to rapidly screen multiple libraries of compounds to find drug hits with biological or pharmaceutical activity. Mass spectrometry (MS) has become a popular option for HTS given that it can simultaneously resolve hundreds to thousands of compounds without additional chemical derivatization. For this application, it is convenient to do direct analysis from well plates. Herein, we present the development of an infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) source coupled directly to an Agilent 6545 for direct analysis from well plates. The source is coupled to a quadrupole time-of-flight (Q-TOF) mass spectrometer to take advantage of the high acquisition rates without sacrificing resolving power as required with Orbitrap or Fourier-transform ion cyclotron resonance (FTICR) instruments. The laser used for this source operates at 100 Hz, firing 1 pulse-per-burst, and delivers around 0.7 mJ per pulse. Continuously firing this laser for an extended duration makes it a quasi-continuous ionization source. Additionally, a metal capillary was constructed to extend the inlet of the mass spectrometer, increase desolvation of electrospray charged droplets, improve ion transmission, and increase sensitivity. Its efficiency was compared with the conventional dielectric glass capillary by measured signal and demonstrated that the metal capillary increased ionization efficiency due to its more uniformly distributed temperature gradient. Finally, we present the functionality of the source by analyzing tune mix directly from well plates. This source is a proof of concept for HTS applications using IR-MALDESI coupled to a different MS platform.
Collapse
|
13
|
Next-Generation Infrared Matrix-Assisted Laser Desorption Electrospray Ionization Source for Mass Spectrometry Imaging and High-Throughput Screening. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:2070-2077. [PMID: 36173393 PMCID: PMC9944128 DOI: 10.1021/jasms.2c00178] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) is a hybrid, ambient ionization source that combines the advantages of electrospray ionization and matrix-assisted laser desorption/ionization, making it a versatile tool for both high-throughput screening (HTS) and mass spectrometry imaging (MSI) studies. To expand the capabilities of the IR-MALDESI source, an entirely new architecture was designed to overcome the key limitations of the previous source. This next-generation (NextGen) IR-MALDESI source features a vertically mounted IR-laser, a planar translation stage with computerized sample height control, an aluminum enclosure, and a novel mass spectrometer interface plate. The NextGen IR-MALDESI source has improved user-friendliness, improved overall versatility, and can be coupled to numerous Orbitrap mass spectrometers to accommodate more research laboratories. In this work, we highlight the benefits of the NextGen IR-MALDESI source as an improved platform for MSI and direct analysis. We also optimize the NextGen MALDESI source component geometries to increase target ion abundances over a wide m/z range. Finally, documentation is provided for each NextGen IR-MALDESI part so that it can be replicated and incorporated into any lab space.
Collapse
|
14
|
Novel matrix strategies for improved ionization and spatial resolution using IR-MALDESI mass spectrometry imaging. JOURNAL OF MASS SPECTROMETRY : JMS 2022; 57:e4875. [PMID: 35900350 PMCID: PMC9541679 DOI: 10.1002/jms.4875] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2022] [Revised: 07/12/2022] [Accepted: 07/15/2022] [Indexed: 05/10/2023]
Abstract
In mass spectrometry imaging (MSI) applications of infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI), an exogenous ice layer is the gold standard for an energy-absorbing matrix. However, the formation of the ice matrix requires additional time and instrument hardware, so glycerol was investigated herein as an alternative to the ice matrix to potentially improve spatial resolution and ionization, while decreasing experiment time. Glycerol solutions of varying concentrations were sprayed over top of rat liver tissue sections for analysis by IR-MALDESI and compared to the typical ice matrix condition. Additionally, we tested if combining the ice matrix and glycerol matrix would further improve analyses. Matrix conditions were evaluated by comparing ion abundance of six lipid species, the laser ablation spot diameter, and number of METASPACE annotations. The ion abundances were also normalized to the volume of tissue ablated to correct for lower abundance values due to less ablated tissue. It was observed that utilizing a 50% glycerol matrix without ice provides improved spatial resolution with lipid abundances and annotations comparable to the ice matrix standard, while decreasing the time required to complete an IR-MALDESI tissue imaging experiment.
Collapse
|
15
|
Normalization techniques for high-throughput screening by infrared matrix-assisted laser desorption electrospray ionization mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2022; 57:e4869. [PMID: 35678360 PMCID: PMC9287052 DOI: 10.1002/jms.4869] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2022] [Revised: 05/21/2022] [Accepted: 05/26/2022] [Indexed: 05/29/2023]
Abstract
Mass spectrometry (MS) is an effective analytical tool for high-throughput screening (HTS) in the drug discovery field. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) MS is a high-throughput platform that has achieved analysis times of sub-seconds-per-sample. Due to the high-throughput analysis speed, methods are needed to increase the analyte signal while decreasing the variability in IR-MALDESI-MS analyses to improve data quality and reduce false-positive hits. The Z-factor is used as a statistic of assay quality that can be improved by reducing the variation of target ion abundances or increasing signal. Herein we report optimal solvent compositions for increasing measured analyte abundances with direct analysis by IR-MALDESI-MS. We also evaluate normalization strategies, such as adding a normalization standard that is similar or dissimilar in structure to the model target drug, to reduce the variability of measured analyte abundances with direct analyses by IR-MALDESI-MS in both positive and negative ionization modes.
Collapse
|
16
|
Abstract
Multimodal mass spectrometry imaging (MSI) is a critical technique used for deeply investigating biological systems by combining multiple MSI platforms in order to gain the maximum molecular information about a sample that would otherwise be limited by a single analytical technique. The aim of this work was to create a multimodal MSI approach that measures metabolomic and proteomic data from a single biological organ by combining infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) for metabolomic MSI and nanodroplet processing in one pot for trace samples (nanoPOTS) LC-MS/MS for spatially resolved proteome profiling. Adjacent tissue sections of rat brain were analyzed by each platform, and each data set was individually analyzed using previously optimized workflows. IR-MALDESI data sets were annotated by accurate mass and spectral accuracy using HMDB, METLIN, and LipidMaps databases, while nanoPOTS-LC-MS/MS data sets were searched against the rat proteome using the Sequest HT algorithm and filtered with a 1% FDR. The combined data revealed complementary molecular profiles distinguishing the corpus callosum against other sampled regions of the brain. A multiomic pathway integration showed a strong correlation between the two data sets when comparing average abundances of metabolites and corresponding enzymes in each brain region. This work demonstrates the first steps in the creation of a multimodal MSI technique that combines two highly sensitive and complementary imaging platforms. Raw data files are available in METASPACE (https://metaspace2020.eu/project/pace-2021) and MassIVE (identifier: MSV000088211).
Collapse
|
17
|
Optimized C-Trap Timing of an Orbitrap 240 Mass Spectrometer for High-Throughput Screening and Native MS by IR-MALDESI. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:328-334. [PMID: 35073091 PMCID: PMC9944060 DOI: 10.1021/jasms.1c00319] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/09/2023]
Abstract
Infrared matrix-assisted laser desorption ionization (IR-MALDESI) is a hybrid mass spectrometry ionization source that combines the benefits of electrospray ionization (ESI) and matrix-assisted laser desorption ionization (MALDI) making it a great analytical tool for high-throughput screening (HTS) analyses. IR-MALDESI is coupled to an Orbitrap Exploris 240 mass spectrometer that utilizes a bent quadrupole (C-trap) to inject accumulated ions into the high-field Orbitrap mass analyzer. Here, we present a study on the optimized C-trap timing for HTS analyses by IR-MALDESI mass spectrometry. The timing between initial ion generation and the C-trap opening time was optimized to reduce unnecessary ambient ion accumulation in the mass spectrometer. The time in which the C-trap was held open, the ion accumulation time, was further optimized to maximize the accumulation of analyte ions generated using IR-MALDESI. The resulting C-trap opening scheme benefits small-molecule HTS analyses by IR-MALDESI by maximizing target ion abundances, minimizing ambient ion abundances, and minimizing the total analysis time per sample. The proposed C-trap timing scheme for HTS does not translate to large molecules; a NIST monoclonal antibody standard reference material was analyzed to demonstrate that larger analytes require longer ion accumulation times and that IR-MALDESI can measure intact antibodies in their native state.
Collapse
|
18
|
Mass Spectrometry Imaging of N-Linked Glycans in a Formalin-Fixed Paraffin-Embedded Human Prostate by Infrared Matrix-Assisted Laser Desorption Electrospray Ionization. J Proteome Res 2022; 21:243-249. [PMID: 34860526 PMCID: PMC9944006 DOI: 10.1021/acs.jproteome.1c00822] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
N-Linked glycans are structurally diverse polysaccharides that represent significant biological relevance due to their involvement in disease progression and cancer. Due to their complex nature, N-linked glycans pose many analytical challenges requiring the continued development of analytical technologies. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) is a hybrid ionization technique commonly used for mass spectrometry imaging (MSI) applications. Previous work demonstrated IR-MALDESI to significantly preserve sialic acid containing N-linked glycans that otherwise require chemical derivatization prior to detection. Here, we demonstrate the first analysis of N-linked glycans in situ by IR-MALDESI MSI. A formalin-fixed paraffin-embedded human prostate tissue was analyzed in negative ionization mode after tissue washing, antigen retrieval, and pneumatic application of PNGase F for enzymatic digestion of N-linked glycans. Fifty-three N-linked glycans were confidently identified in the prostate sample where more than 60% contained sialic acid residues. This work demonstrates the first steps in N-linked glycan imaging of biological tissues by IR-MALDESI MSI. Raw data files are available in MassIVE (identifier: MSV000088414).
Collapse
|
19
|
Enhancing Metabolomic Coverage in Positive Ionization Mode Using Dicationic Reagents by Infrared Matrix-Assisted Laser Desorption Electrospray Ionization. Metabolites 2021; 11:810. [PMID: 34940568 PMCID: PMC8708802 DOI: 10.3390/metabo11120810] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2021] [Revised: 11/19/2021] [Accepted: 11/23/2021] [Indexed: 11/16/2022] Open
Abstract
Mass spectrometry imaging is a powerful tool to analyze a large number of metabolites with their spatial coordinates collected throughout the sample. However, the significant differences in ionization efficiency pose a big challenge to metabolomic mass spectrometry imaging. To solve the challenge and obtain a complete data profile, researchers typically perform experiments in both positive and negative ionization modes, which is time-consuming. In this work, we evaluated the use of the dicationic reagent, 1,5-pentanediyl-bis(1-butylpyrrolidinium) difluoride (abbreviated to [C5(bpyr)2]F2) to detect a broad range of metabolites in the positive ionization mode by infrared matrix-assisted laser desorption electrospray ionization mass spectrometry imaging (IR-MALDESI MSI). [C5(bpyr)2]F2 at 10 µM was doped in 50% MeOH/H2O (v/v) electrospray solvent to form +1 charged adducted ions with anionic species (-1 charged) through post-electrospray ionization. This method was demonstrated with sectioned rat liver and hen ovary. A total of 73 deprotonated metabolites from rat liver tissue sections were successfully adducted with [C5(bpyr)2]2+ and putatively identified in the adducted positive ionization polarity, along with 164 positively charged metabolite ions commonly seen in positive ionization mode, which resulted in 44% increased molecular coverage. In addition, we were able to generate images of hen ovary sections showing their morphological features. Following-up tandem mass spectrometry (MS/MS) indicated that this dicationic reagent [C5(bpyr)2]2+ could form ionic bonds with the headgroup of glycerophospholipid ions. The addition of the dicationic reagent [C5(bpyr)2]2+ in the electrospray solvent provides a rapid and effective way to enhance the detection of metabolites in positive ionization mode.
Collapse
|
20
|
Multiple Infusion Start Time Mass Spectrometry Imaging of Dynamic SIL-Glutathione Biosynthesis Using Infrared Matrix-Assisted Laser Desorption Electrospray Ionization. J Proteome Res 2021; 21:747-757. [PMID: 34807624 DOI: 10.1021/acs.jproteome.1c00636] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Due to the high association of glutathione metabolism perturbation with a variety of disease states, there is a dire need for analytical techniques to study glutathione kinetics. Additionally, the elucidation of microenvironmental effects on changes in glutathione metabolism would significantly improve our understanding of the role of glutathione in disease. We therefore present a study combining a multiple infusion start time protocol, stable isotope labeling technology, infrared matrix-assisted laser desorption electrospray ionization, and high-resolution accurate mass-mass spectrometry imaging to study spatial changes in glutathione kinetics across in sectioned mouse liver tissues. After injecting a mouse with the isotopologues [2-13C,15N]-glycine, [1,2-13C2]-glycine, and [1,2-13C2,15N]-glycine at three different time points, we were able to fully resolve and spatially map their metabolism into three isotopologues of glutathione and calculate their isotopic enrichment in glutathione. We created a tool in the open-source mass spectrometry imaging software MSiReader to accurately compute the percent isotope enrichment (PIE) of these labels in glutathione and visualize them in heat-maps of the tissue sections. In areas of high flux, we found that each label enriched an approximate median of 1.6%, 1.8%, and 1.5%, respectively, of the glutathione product pool measured in each voxel. This method may be adapted to study the heterogeneity of glutathione flux in diseased versus healthy tissues.
Collapse
|
21
|
Vitamin D deficiency promotes accumulation of bioactive lipids and increased endocannabinoid tone in zebrafish. J Lipid Res 2021; 62:100142. [PMID: 34673019 PMCID: PMC8604674 DOI: 10.1016/j.jlr.2021.100142] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Revised: 10/09/2021] [Accepted: 10/11/2021] [Indexed: 12/29/2022] Open
Abstract
Vitamin D is well known for its traditional role in bone mineral homeostasis; however, recent evidence suggests that vitamin D also plays a significant role in metabolic control. This study served to investigate putative linkages between vitamin D deficiency (VDD) and metabolic disruption of bioactive lipids by MS imaging. Our approach employed infrared-matrix-assisted laser desorption electrospray ionization MS imaging for lipid metabolite profiling in 6-month-old zebrafish fed either a VDD or a vitamin D-sufficient (VDS) diet. Using a lipidomics pipeline, we found that VDD zebrafish had a greater abundance of bioactive lipids (N-acyls, endocannabinoids [ECs], diacylglycerols/triacylglycerols, bile acids/bile alcohols, and vitamin D derivatives) suggestive of increased EC tone compared with VDS zebrafish. Tandem MS was performed on several differentially expressed metabolites with sufficient ion abundances to aid in structural elucidation and provide additional support for MS annotations. To confirm activation of the EC pathways, we subsequently examined expression of genes involved in EC biosynthesis, metabolism, and receptor signaling in adipose tissue and liver from VDD and VDS zebrafish. Gene expression changes were congruent with increased EC tone, with VDD zebrafish demonstrating increased synthesis and metabolism of anandamide compared with VDS zebrafish. Taken together, our data suggest that VDD may promote accumulation of bioactive lipids and increased EC tone in zebrafish.
Collapse
|
22
|
Three-dimensional (3D) imaging of lipids in skin tissues with infrared matrix-assisted laser desorption electrospray ionization (MALDESI) mass spectrometry. Anal Bioanal Chem 2021; 413:2793-2801. [PMID: 33388847 DOI: 10.1007/s00216-020-03105-6] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2020] [Revised: 11/22/2020] [Accepted: 11/30/2020] [Indexed: 12/14/2022]
Abstract
Three-dimensional (3D) mass spectrometry imaging (MSI) has become a growing frontier as it has the potential to provide a 3D representation of analytes in a label-free, untargeted, and chemically specific manner. The most common 3D MSI is accomplished by the reconstruction of 2D MSI from serial cryosections; however, this presents significant challenges in image alignment and registration. An alternative method would be to sequentially image a sample by consecutive ablation events to create a 3D image. In this study, we describe the use of infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) in ablation-based 3D MSI for analyses of lipids within fresh frozen skin tissue. Depth resolution using different laser energy levels was explored with a confocal laser scanning microscope to establish the imaging parameters for skin. The lowest and highest laser energy level resulted in a depth resolution of 7 μm and 18 μm, respectively. A total of 594 lipids were putatively detected and detailed lipid profiles across different skin layers were revealed in a 56-layer 3D imaging experiment. Correlated with histological information, the skin structure was characterized with differential lipid distributions with a lateral resolution of 50 μm and a z resolution of 7 μm.
Collapse
|
23
|
Lipidomic profiling of single mammalian cells by infrared matrix-assisted laser desorption electrospray ionization ( IR-MALDESI). Anal Bioanal Chem 2020; 412:8211-8222. [PMID: 32989513 PMCID: PMC7606626 DOI: 10.1007/s00216-020-02961-6] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Revised: 09/11/2020] [Accepted: 09/18/2020] [Indexed: 10/23/2022]
Abstract
To better understand cell-to-cell heterogeneity, advanced analytical tools are in a growing demand for elucidating chemical compositions of each cell within a population. However, the progress of single-cell chemical analysis has been restrained by the limitations of small cell volumes and minute cellular concentrations. Here, we present a rapid and sensitive method for investigating the lipid profiles of isolated single cells using infrared matrix-assisted laser desorption electrospray ionization mass spectrometry (IR-MALDESI-MS). In this work, HeLa cells were dispersed onto a glass slide, and the cellular contents were ionized by IR-MALDESI and measured using a Q-Exactive HF-X mass spectrometer. Importantly, this approach does not require extraction and/or enrichment of analytes prior to MS analysis. Using this approach, 45 distinct lipid species, predominantly phospholipids, were detected and putatively annotated from the single HeLa cells. The proof-of-concept study demonstrates the feasibility and efficacy of IR-MALDESI-MS for rapid lipidomic profiling of single cells, which provides an important basis for future work on differentiation between normal and diseased cells at various developmental states, which can offer new insights into cellular metabolic pathways and pathological processes. Although not yet accomplished, we believe this approach can be readily used as an assessment tool to compare the number of identified species during source evolution and method optimization (intra-laboratory), and also disclose the complementary nature of different direct analytical approaches for the coverage of different types of endogenous analytes (inter-laboratory).Graphical abstract.
Collapse
|
24
|
Direct Analysis of Native N-Linked Glycans by IR-MALDESI. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:10.1021/jasms.0c00176. [PMID: 32603137 PMCID: PMC8285077 DOI: 10.1021/jasms.0c00176] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Glycan analysis by mass spectrometry has rapidly progressed due to the interest in understanding the role of glycans in disease and tumor progression. Glycans are complex molecules that pose analytical challenges due to their isomeric compositions, labile character, and ionization preferences. This study sought to demonstrate infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) as a novel approach for the direct analysis of N-linked glycans. The glycoprotein bovine fetuin was chosen for this analysis as its glycome is well-characterized and heavily composed of sialylated glycans. Native N-linked glycans produced by enzymatic cleavage (via PNGase F) of bovine fetuin were analyzed directly by IR-MALDESI in both positive and negative ionization mode. In this study, we detected 12 N-linked glycans in negative mode and 4 N-linked glycans in positive mode, a significant increase in the amount of underivatized glycans detected by other ionization sources. Importantly, all N-linked glycans detected contained at least one sialic acid residue, which are known to be labile. This work represents a critical first step for N-linked glycan analysis by IR-MALDESI with future efforts directed at mass spectrometry imaging.
Collapse
|
25
|
Analysis of neurotransmitters in rat placenta exposed to flame retardants using IR-MALDESI mass spectrometry imaging. Anal Bioanal Chem 2020; 412:3745-3752. [PMID: 32300844 DOI: 10.1007/s00216-020-02626-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2020] [Revised: 03/21/2020] [Accepted: 03/27/2020] [Indexed: 01/12/2023]
Abstract
Chemical exposures can adversely impact fetal development. For many compounds, including common flame retardants, the mechanisms by which this occurs remain unclear, but emerging evidence suggests that disruption at the level of the placenta may play a role. Understanding how the placenta might be vulnerable to chemical exposures is challenging due to its complex structure. The primary objective of this study was to develop a method for detecting placental neurotransmitters and related metabolites without chemical derivatization so changes in the abundance and spatial distribution of neurotransmitters in rat placenta following chemical exposure could be determined using infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) mass spectrometry imaging. Without chemical derivatization, 49 neurotransmitters and their related metabolites were putatively identified in untreated rat placenta sections using mass measurement accuracy and spectral accuracy. A few neurotransmitters were less abundant in placentas that were exposed to various flame retardants and were further investigated by KEGG metabolic pathway analysis. Many of these downregulated neurotransmitters shared the same enzyme responsible for metabolism, aromaticl-amino acid decarboxylase, suggesting a mechanistic role. These data constitute a new approach that could help identify novel mechanisms of toxicity in complex tissues. Graphical abstract.
Collapse
|
26
|
Methods for Cryosectioning and Mass Spectrometry Imaging of Whole-Body Zebrafish. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:768-772. [PMID: 32129621 PMCID: PMC9375048 DOI: 10.1021/jasms.9b00097] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
The zebrafish (Danio rerio) is an ideal model for whole animal studies of lipid metabolism and lipid-related disease. In this work, infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) mass spectrometry imaging (MSI) was applied for direct visualization of lipid and metabolite distributions across various organs in whole-body zebrafish tissue sections. Detailed methods for overcoming the challenges of cryosectioning adult male zebrafish for MSI and complementary histological imaging are described. Representative two-dimensional ion maps demonstrated organ specific localization of lipid analytes allowing for visualization of areas of interest including the brain, liver, intestines, and skeletal muscle. A high resolving power mass spectrometer was utilized for accurate mass measurements, which permitted the use of open-source, web-based tools for MS1 annotations including METASPACE and METLIN. Whole-body MSI with IR-MALDESI allowed for broad lipid coverage with high spatial resolution, illustrating the potential of this technique for studying lipid-related diseases using zebrafish as a model organism.
Collapse
|
27
|
Coupling IR-MALDESI with Drift Tube Ion Mobility-Mass Spectrometry for High-Throughput Screening and Imaging Applications. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:642-650. [PMID: 31971795 PMCID: PMC7263366 DOI: 10.1021/jasms.9b00081] [Citation(s) in RCA: 21] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
Because of its high degree of selectivity and chemical resolution, mass spectrometry (MS) is rapidly becoming the analytical method of choice for high-throughput evaluations and clinical diagnostics. While advances in MS resolving power have increased by an order of magnitude over the past decade, advances in sample introduction are still needed for high-throughput screening applications where the time frame of chromatographic separation would limit the duty cycle. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) is an ambient ionization source that has been shown to be applicable for direct analyses and mass spectrometry imaging (MSI) of complex biological samples in a high-throughput manner. To increase a range of detectable features in IR-MALDESI experiments, we integrated the home-built ion source with a commercially available drift tube ion mobility spectrometer-mass spectrometer (IMS-MS) and analyzed small polar molecules, lipids, carbohydrates, and intact proteins. We also describe in detail how the pulsed ionization source was synchronized with IMS-MS.
Collapse
|
28
|
Three-Dimensional Imaging with Infrared Matrix-Assisted Laser Desorption Electrospray Ionization Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:292-297. [PMID: 32031410 PMCID: PMC8284694 DOI: 10.1021/jasms.9b00066] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Mass spectrometry imaging as a field has pushed its frontiers to three dimensions. Most three-dimensional mass spectrometry imaging (3D MSI) approaches require serial sectioning that results in a loss of biological information between analyzed slices and difficulty in reconstruction of 3D images. In this contribution, infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) was demonstrated to be applicable for 3D MSI that does not require sectioning because IR laser ablates material on a micrometer scale. A commercially available over-the-counter pharmaceutical was used as a model to demonstrate the feasibility of IR-MALDESI for 3D MSI. Depth resolution (i.e., z-resolution) as a function of laser energy levels and density of ablated material was investigated. The best achievable depth resolution from a pill was 2.3 μm at 0.3 mJ/pulse. 2D and 3D MSI were performed on the tablet to show the distribution of pill-specific molecules. A 3D MSI analysis on a region of interest of 15 × 15 voxels across 50 layers was performed. Our results demonstrate that IR-MALDESI is feasible with 3D MSI on a pill, and future work will be focused on analyses of biological tissues.
Collapse
|
29
|
Determination of Optimal Electrospray Parameters for Lipidomics in Infrared-Matrix-Assisted Laser Desorption Electrospray Ionization Mass Spectrometry Imaging. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:319-325. [PMID: 32031399 PMCID: PMC10861021 DOI: 10.1021/jasms.9b00063] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Infrared matrix-assisted laser desorption ionization (IR-MALDESI) is an ambient mass spectrometry imaging (MSI) technique that relies on electrospray ionization (ESI) for ion generation of desorbed neutrals. Although many mechanisms in IR-MALDESI have been studied in depth, there has not yet been a comprehensive study of how the ESI parameters change the profiles of tissue specific lipids. Acetonitrile (ACN)/water and methanol (MeOH)/water solvent systems and compositions were varied across a series of applied ESI voltages during IR-MALDESI analysis of rat liver tissue. Gradients of 12 min were run from 5 to 95% organic solvent in both positive and negative polarities across 11 voltages between 2.25 and 4.5 kV. These experiments informed longer gradients (25-30 min) across shorter solvent gradient ranges with fewer voltages. Optimal ESI parameters for lipidomics were determined by the number and abundance of detected lipids and the relative proportion of background ions. In positive polarity, the best solvent composition was 60-75% ACN/40-25% H2O with 0.2% formic acid at 3.2 kV applied voltage. The best parameters for negative polarity analysis are 45-55% ACN/55-45% H2O with 1 mM of acetic acid for voltages between 2.25 and 3.2 kV. Using these defined parameters, IR-MALDESI positive polarity lipidomics studies can increase lipid abundances 3-fold, with 15% greater coverage, while an abundance increase of 1.5-fold and 10% more coverage can be achieved relative to commonly used parameters in negative polarity.
Collapse
|
30
|
Investigating host-pathogen meta-metabolic interactions of Magnaporthe oryzae infected barley using infrared matrix-assisted laser desorption electrospray ionization mass spectrometry. Anal Bioanal Chem 2019; 412:139-147. [PMID: 31760448 DOI: 10.1007/s00216-019-02216-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2019] [Revised: 10/10/2019] [Accepted: 10/15/2019] [Indexed: 12/11/2022]
Abstract
Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) mass spectrometry imaging is a useful tool for identifying important meta-metabolomic features pertinent for enhancing our understanding of biological systems. Magnaporthe oryzae (M. oryzae) is a filamentous fungus that is the primary cause of rice blast disease. True to its name, M. oryzae primarily destroys rice crops and can also destroy other cereal crops as well. In a previous study, the F-box E3 ligase protein in M. oryzae was noted to be crucial for its growth and pathogenicity. In this study, we inoculated three separate sets of barley with wild-type M. oryzae, an F-box E3 ligase protein knock out of M. oryzae, and a control solution. Over the course of the infection (8 days), we imaged each treatment after development of an advanced polarity switching method, which allowed for the detection of low and high molecular weight compounds that ionize in positive or negative polarities. A set of features from initial experiments were chosen for another analysis using tandem mass spectrometry. Serotonin, a barley defense metabolite, was a compound identified in both positive and negative modes. Serotonin was putatively identified using MS1 data including carbon estimation and sulfur counting then confirmed based on tandem mass spectrometry fragmentation patterns. Metabolites in the melanin pathway, important for infection development of M. oryzae, were also identified using MS1 data but were unable to be confirmed with MS/MS due to their low abundances.
Collapse
|
31
|
Internal Energy Deposition in Infrared Matrix-Assisted Laser Desorption Electrospray Ionization With and Without the Use of Ice as a Matrix. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2019; 30:2380-2391. [PMID: 31502226 PMCID: PMC6937789 DOI: 10.1007/s13361-019-02323-2] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Revised: 08/13/2019] [Accepted: 08/14/2019] [Indexed: 05/08/2023]
Abstract
The internal energy deposited into analytes during the ionization process largely influences the extent of fragmentation, thus the appearance of the resulting mass spectrum. The internal energy distributions of a series of para-substituted benzyl pyridinium cations in liquid and solid-state generated by infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) were measured using the survival yield method, of which results were subsequently compared with conventional electrospray ionization (ESI). The comparable mean internal energy values (e.g., 1.8-1.9 eV at a collision energy of 15 eV) and peak widths obtained with IR-MALDESI and ESI support that IR-MALDESI are essentially a soft ionization technique where analytes do not gain considerable internal energy during the laser-induced desorption process and/or lose energy during uptake into charged electrospray droplets. An unusual fragment ion, protonated pyridine, was only found for solid IR-MALDESI at relatively high collision energies, which is presumably resulted from direct ionization of the pre-charged analytes in form of salts. Analysis of tissue with an ice layer consistently yielded ion populations with higher internal energy than its counterpart without an ice layer, likely due to a substantially enhanced number of IR absorbers with ice. Further measurements with holo-myoglobin show that IR-MALDESI-MS retains the noncovalently bound heme-protein complexes under both native-like and denaturing conditions, while complete loss of the heme group occurred in denaturing ESI-MS, showing that the softness of IR-MALDESI is equivalent or superior to ESI for biomolecules.
Collapse
|
32
|
Systematic evaluation of repeatability of IR-MALDESI-MS and normalization strategies for correcting the analytical variation and improving image quality. Anal Bioanal Chem 2019; 411:5729-5743. [PMID: 31240357 DOI: 10.1007/s00216-019-01953-5] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2019] [Revised: 05/21/2019] [Accepted: 05/28/2019] [Indexed: 12/20/2022]
Abstract
Mass spectrometry imaging is a powerful tool widely used in biological, clinical, and forensic research, but its often poor repeatability limits its application for quantitative and large-scale analysis. A systematic evaluation of infrared matrix-assisted laser desorption electrospray ionization mass spectrometry (IR-MALDESI-MS) repeatability in absolute ion abundances during short- and long-term experiments was carried out on liver slices from the same rat with minimal biological variability to be expected. Results of median %RSDs ranging from 14 to 45, pooled %RMADs ranging from 11 to 33, and Pearson correlation coefficients ranging from 0.83 to 1.00 demonstrated an acceptable repeatability of IR-MALDESI-MS. Normalization is commonly applied for the purpose of accounting for analytical variability of spectra generated from different runs so as to reveal real biological differences. Nine data normalization strategies were performed on the rat liver data sets to examine their effects on reducing analytical variation, and further on a hen ovary data set containing more morphological features for the investigation of their impact on ion images. Results demonstrated that the majority of normalization approaches benefit data quality to some extent, and local normalization methods significantly outperform their global counterparts, resulting in a reduction of median %RSD up to 22. Local median normalization was found to be promisingly robust for both homogeneous and heterogeneous samples.
Collapse
|
33
|
IR-MALDESI mass spectrometry imaging of underivatized neurotransmitters in brain tissue of rats exposed to tetrabromobisphenol A. Anal Bioanal Chem 2018; 410:7979-7986. [PMID: 30317443 PMCID: PMC6235718 DOI: 10.1007/s00216-018-1420-0] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2018] [Revised: 09/23/2018] [Accepted: 10/04/2018] [Indexed: 11/26/2022]
Abstract
There is a pressing need to develop tools for assessing possible neurotoxicity, particularly for chemicals where the mode of action is poorly understood. Tetrabromobisphenol A (TBBPA), a highly abundant brominated flame retardant, has lately been targeted for neurotoxicity analysis by concerned public health entities in the EU and USA because it is a suspected thyroid disruptor and neurotoxicant. In this study, infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) coupled to a Q Exactive Plus mass spectrometer was used for the analysis of neurotransmitters in the brains of rats exposed to TBBPA in gestation and lactation through their mothers. Three neurotransmitters of interest were studied in three selected regions of the brain: caudate putamen, substantia nigra (SN), and dorsal raphe. Stable isotope labeled (SIL) standards were used as internal standards and a means to achieve relative quantification. This study serves as a demonstration of a new application of IR-MALDESI, namely that neurotransmitter distributions can be confidently and rapidly imaged without derivatization.
Collapse
|
34
|
Characterization of a novel miniaturized burst-mode infrared laser system for IR-MALDESI mass spectrometry imaging. Anal Bioanal Chem 2018; 410:2395-2402. [PMID: 29455285 DOI: 10.1007/s00216-018-0918-9] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2017] [Revised: 01/13/2018] [Accepted: 01/24/2018] [Indexed: 11/27/2022]
Abstract
Laser systems are widely used in mass spectrometry as sample probes and ionization sources. Mid-infrared lasers are particularly suitable for analysis of high water content samples such as animal and plant tissues, using water as a resonantly excited sacrificial matrix. Commercially available mid-IR lasers have historically been bulky and expensive due to cooling requirements. This work presents a novel air-cooled miniature mid-IR laser with adjustable burst-mode output and details an evaluation of its performance for mass spectrometry imaging. The miniature laser was found capable of generating sufficient energy for complete ablation of animal tissue in the context of an IR-MALDESI experiment with exogenously added ice matrix, yielding several hundred confident metabolite identifications. Graphical abstract The use of a novel miniature 2.94 μm burst-mode laser in IR-MALDESI allows for rapid and sensitive mass spectrometry imaging of a whole mouse.
Collapse
|
35
|
IR-MALDESI Mass Spectrometry Imaging at 50 Micron Spatial Resolution. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:2099-2107. [PMID: 28721672 PMCID: PMC5693761 DOI: 10.1007/s13361-017-1740-x] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/25/2017] [Revised: 06/15/2017] [Accepted: 06/15/2017] [Indexed: 05/04/2023]
Abstract
High spatial resolution in mass spectrometry imaging (MSI) is crucial to understanding the biology dictated by molecular distributions in complex tissue systems. Here, we present MSI using infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) at 50 μm resolution. An adjustable iris, beam expander, and an aspherical focusing lens were used to reduce tissue ablation diameters for MSI at high resolution. The laser beam caustic was modeled using laser ablation paper to calculate relevant laser beam characteristics. The minimum laser spot diameter on the tissue was determined using tissue staining and microscopy. Finally, the newly constructed optical system was used to image hen ovarian tissue with and without oversampling, detailing tissue features at 50 μm resolution. Graphical Abstract ᅟ.
Collapse
|
36
|
IR-MALDESI method optimization based on time-resolved measurement of ion yields. Anal Bioanal Chem 2017; 410:963-970. [PMID: 28852816 DOI: 10.1007/s00216-017-0585-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Accepted: 08/11/2017] [Indexed: 12/28/2022]
Abstract
In the field of mass spectrometry imaging, typical experiments involve ionization directly from complex samples with no pre-ionization separation, relying on high resolving power mass analyzers to separate ions of interest. When an ion trapping step is involved in the analysis, the dynamic range of the analysis may be limited by the capacity of the ion trap, which is easily exceeded. To minimize collection of undesired ambient species while maximizing collection of analyte signal, accurate timing between ion generation and collection is a requirement. Here, a method for achieving synchronicity between infrared laser ablation and ion collection on a Q Exactive Plus mass spectrometer is described and demonstrated through measurement of ion accumulation at fixed time points following a laser ablation event with electrospray post-ionization of ablated material. In a model imaging experiment using infrared matrix-assisted laser desorption electrospray ionization, fixing the injection time at the minimum duration required to capture all ions generated by the last laser pulse in a sequence is shown to maximize target ion abundances. Using optimized timing is shown to yield a doubling or better of useful signal compared to previously used parameters. Graphical abstract Illustration of the effects of signal optimization on data quality for a single lipid species (cholesterol) measured from mouse liver tissue.
Collapse
|
37
|
Direct analysis of terpenes from biological buffer systems using SESI and IR-MALDESI. Anal Bioanal Chem 2017; 410:953-962. [PMID: 28819677 DOI: 10.1007/s00216-017-0570-9] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2017] [Revised: 07/24/2017] [Accepted: 08/04/2017] [Indexed: 01/27/2023]
Abstract
Terpenes are the largest class of natural products with a wide range of applications including use as pharmaceuticals, fragrances, flavorings, and agricultural products. Terpenes are biosynthesized by the condensation of a variable number of isoprene units resulting in linear polyisoprene diphosphate units, which can then be cyclized by terpene synthases into a range of complex structures. While these cyclic structures have immense diversity and potential in different applications, their direct analysis in biological buffer systems requires intensive sample preparation steps such as salt cleanup, extraction with organic solvents, and chromatographic separations. Electrospray post-ionization can be used to circumvent many sample cleanup and desalting steps. SESI and IR-MALDESI are two examples of ionization methods that employ electrospray post-ionization at atmospheric pressure and temperature. By coupling the two techniques and doping the electrospray solvent with silver ions, olefinic terpenes of different classes and varying degrees of volatility were directly analyzed from a biological buffer system with no sample workup steps.
Collapse
|
38
|
Direct Analysis of Triterpenes from High-Salt Fermented Cucumbers Using Infrared Matrix-Assisted Laser Desorption Electrospray Ionization ( IR-MALDESI). JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:370-375. [PMID: 27848143 DOI: 10.1007/s13361-016-1541-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2016] [Revised: 10/17/2016] [Accepted: 10/20/2016] [Indexed: 05/11/2023]
Abstract
High-salt samples present a challenge to mass spectrometry (MS) analysis, particularly when electrospray ionization (ESI) is used, requiring extensive sample preparation steps such as desalting, extraction, and purification. In this study, infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) coupled to a Q Exactive Plus mass spectrometer was used to directly analyze 50-μm thick slices of cucumber fermented and stored in 1 M sodium chloride brine. From the several hundred unique substances observed, three triterpenoid lipids produced by cucumbers, β-sitosterol, stigmasterol, and lupeol, were putatively identified based on exact mass and selected for structural analysis. The spatial distribution of the lipids were imaged, and the putative assignments were confirmed by tandem mass spectrometry performed directly on the same cucumber, demonstrating the capacity of the technique to deliver confident identifications from highly complex samples in molar concentrations of salt without the need for sample preparation. Graphical Abstract ᅟ.
Collapse
|
39
|
TransOmic analysis of forebrain sections in Sp2 conditional knockout embryonic mice using IR-MALDESI imaging of lipids and LC-MS/MS label-free proteomics. Anal Bioanal Chem 2016; 408:3453-74. [PMID: 26942738 DOI: 10.1007/s00216-016-9421-3] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2015] [Revised: 02/08/2016] [Accepted: 02/12/2016] [Indexed: 10/22/2022]
Abstract
Quantitative methods for detection of biological molecules are needed more than ever before in the emerging age of "omics" and "big data." Here, we provide an integrated approach for systematic analysis of the "lipidome" in tissue. To test our approach in a biological context, we utilized brain tissue selectively deficient for the transcription factor Specificity Protein 2 (Sp2). Conditional deletion of Sp2 in the mouse cerebral cortex results in developmental deficiencies including disruption of lipid metabolism. Silver (Ag) cationization was implemented for infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) to enhance the ion abundances for olefinic lipids, as these have been linked to regulation by Sp2. Combining Ag-doped and conventional IR-MALDESI imaging, this approach was extended to IR-MALDESI imaging of embryonic mouse brains. Further, our imaging technique was combined with bottom-up shotgun proteomic LC-MS/MS analysis and western blot for comparing Sp2 conditional knockout (Sp2-cKO) and wild-type (WT) cortices of tissue sections. This provided an integrated omics dataset which revealed many specific changes to fundamental cellular processes and biosynthetic pathways. In particular, step-specific altered abundances of nucleotides, lipids, and associated proteins were observed in the cerebral cortices of Sp2-cKO embryos.
Collapse
|
40
|
Assessing drug and metabolite detection in liver tissue by UV-MALDI and IR-MALDESI mass spectrometry imaging coupled to FT-ICR MS. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY 2015; 377:448-155. [PMID: 26056514 PMCID: PMC4456684 DOI: 10.1016/j.ijms.2014.05.012] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Determining the distribution of a drug and its metabolites within tissue is a key facet of evaluating drug candidates. Drug distribution can have a significant implication in appraising drug efficacy and potential toxicity. The specificity and sensitivity of mass spectrometry imaging (MSI) make it a perfect complement to the analysis of drug distributions in tissue. The detection of lapatinib as well as several of its metabolites in liver tissue was determined by MSI using infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) coupled to high resolving power Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometers. IR-MALDESI required minimal sample preparation while maintaining high sensitivity. The effect of the electrospray solvent composition on IR-MALDESI MSI signal from tissue analysis was investigated and an empirical comparison of IR-MALDESI and UV-MALDI for MSI analysis is also presented.
Collapse
|