1
|
MOF-derived porous carbon microspheres Ni@C-acid as solid-phase microextraction coating for extraction of polycyclic aromatic hydrocarbons from tea infusions. J Chromatogr A 2024; 1726:464961. [PMID: 38723491 DOI: 10.1016/j.chroma.2024.464961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2024] [Revised: 04/07/2024] [Accepted: 04/30/2024] [Indexed: 05/23/2024]
Abstract
The improvement of the stability and adsorption properties of materials on targets in sample pre-treatment has long been an objective. Extensive efforts have been made to achieve this goal. In this work, metal-organic framework Ni-MOF precursors were first synthesized by solvothermal method using polyvinylpyrrolidone (PVP) as an ideal templating agent, stabiliser and nanoparticle dispersant. After carbonization and acid washing, the nanoporous carbon microspheres material (Ni@C-acid) was obtained. Compared with the material without acid treatment (Ni@C), the specific surface area, pore volume, adsorption performance of Ni@C-acid were increased. Thanks to its excellent characteristics (high stability, abundant benzene rings), Ni@C-acid was used as fiber coatings in headspace solid-phase microextraction (HS-SPME) technology for extraction and preconcentration of polycyclic aromatic hydrocarbons (PAHs) prior to gas chromatography-flame ionization detector (GC-FID) analysis. The experimental parameters of extraction temperature, extraction time, agitation speed, desorption temperature, desorption time and sodium chloride (NaCl) concentration were studied. Under optimal experimental conditions, the wide linear range (0.01-30 ng mL-1), the good correlation coefficient (0.9916-0.9984), the low detection limit (0.003-0.011 ng mL-1), and the high enrichment factor (5273-13793) were obtained. The established method was successfully used for the detection of trace PAHs in actual tea infusions samples and satisfied recoveries ranging from 80.94-118.62 % were achieved. The present work provides a simple method for the preparation of highly stable and adsorbable porous carbon microsphere materials with potential applications in the extraction of environmental pollutants.
Collapse
|
2
|
Predicting the bioavailability of polycyclic aromatic hydrocarbons in rhizosphere soil using a new novel in situ solid-phase microextraction technique. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 930:172802. [PMID: 38679093 DOI: 10.1016/j.scitotenv.2024.172802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/05/2024] [Revised: 04/03/2024] [Accepted: 04/25/2024] [Indexed: 05/01/2024]
Abstract
In situ measurement of the bioavailability of organic pollutants in soil is crucial for understanding their environmental behavior and assessing health risks. Due to the high heterogeneity of soil, microscale determination is crucial for achieving high accuracy, but few methods are available. In this study, microsized probes coated with polydimethylsiloxane (PDMS) were used to measure the bioavailability of polycyclic aromatic hydrocarbons (PAHs) in soil in situ. The concentrations of PAHs enriched by the PDMS-coated probes correlated well with the results of bioassays using earthworms (R2 = 0.92-0.99) and ryegrass roots (R2 = 0.92-0.99). Compared with other chemical extraction methods, such as n-butanol extraction, the proposed method has advantages such as in situ operation, microvolume analysis, and negligible interference to the soil environment. In the soil rhizosphere zone, PAHs bioavailability decreased in the following order: rhizosphere > near-rhizosphere > far-rhizosphere. The bioavailability of PAHs in soil amended with biochar was also successfully characterized by the proposed method. Thus, this study developed an in situ and microscale method to predict the bioavailability of organic pollutants in contaminated soils and provides new insight into migration and transformation processes in rhizosphere soil.
Collapse
|
3
|
Vacuum-assisted and multi-cumulative trapping in headspace solid-phase microextraction combined with comprehensive multidimensional chromatography-mass spectrometry for profiling virgin olive oil aroma. Food Chem 2024; 442:138409. [PMID: 38237298 DOI: 10.1016/j.foodchem.2024.138409] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Revised: 12/21/2023] [Accepted: 01/08/2024] [Indexed: 02/15/2024]
Abstract
In the present work vacuum (Vac) and multiple cumulative trapping (MCT) headspace solid phase microextraction (HS-SPME) were evaluated as alternative or combined techniques for the volatile profiling. A higher extraction performance for semi-volatiles was shown by all three techniques. Synergic combination of Vac and MCT showed up to 5-times extraction power for less volatile compounds. The hyphenation of said techniques with comprehensive two-dimensional gas chromatography (GC × GC) enabled a comprehensive analysis of the volatilome. Firstly, 18 targeted quality markers, previously defined by means of classical HS-SPME, were explored for their ability to classify commercial categories. The applicability of such markers proved to be limited with the alternative sampling techniques. An untargeted approach enables the selection of specific features for each technique showing a better classification capacity of the commercial categories. No misclassifications were observed, except for one extra virgin olive oil classified as virgin olive oil in 3 × 10 min Vac-MCT-HS-SPME.
Collapse
|
4
|
In vivo profiling of phytocannabinoids in Cannabis spp. varieties via SPME-LC-MS analysis. Anal Chim Acta 2024; 1306:342621. [PMID: 38692790 DOI: 10.1016/j.aca.2024.342621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Revised: 03/19/2024] [Accepted: 04/17/2024] [Indexed: 05/03/2024]
Abstract
BACKGROUND In vivo solid-phase microextraction (SPME) is a minimally invasive, non-exhaustive sample-preparation technique that facilitates the direct isolation of low molecular weight compounds from biological matrices in living systems. This technique is especially useful for the analysis of phytocannabinoids (PCs) in plant material, both for forensic purposes and for monitoring the PC content in growing Cannabis spp. plants. In contrast to traditional extraction techniques, in vivo SPME enables continuous tracking of the changes in the level of PCs during plant growth without the need for plant material collection. In this study, in vivo SPME utilizing biocompatible C18 probes and liquid-chromatography coupled to quadrupole time-of flight mass spectrometry (LC-Q-TOF-MS) is proposed as a novel strategy for the extraction and analysis of the acidic forms of five PCs in growing medicinal cannabis plants. RESULTS The SPME method was optimized by testing various parameters, including the extraction phase (coating), extraction and desorption times, and the extraction temperature. The proposed method was validated with satisfactory analytical performance regarding linearity (10-3000 ng/mL), limits of quantification, and precision (relative standard deviations below 5.5 %). The proposed method was then successfully applied for the isolation of five acidic forms of PCs, which are main components of growing medicinal cannabis plants. As a proof-of-concept, SPME probes were statically inserted into the inflorescences of two varieties of Cannabis spp. plants (i.e., CBD-dominant and Δ9-THC-dominant) cultivated under controlled conditions for 30 min extraction of tetrahydrocannabinolic acid (Δ9-THCA), cannabidiolic acid (CBDA), cannabigerolic acid (CBGA), cannabiviarinic acid (CBVA), and tetrahydrocannabivarinic acid (THCVA). SIGNIFICANCE AND NOVELTY The results confirmed that the developed SPME-LC-Q-TOF-MS method is a precise and efficient tool that enables direct and rapid isolation and analysis of PCs under in vivo conditions. The proposed methodology is highly appealing option for monitoring the metabolic pathways and compositions of multiple PCs in medicinal cannabis at different stages of plant growth.
Collapse
|
5
|
Ordered mesoporous hairbrush-like nanocarbon assembled microfibers for solid-phase microextraction of benzene series in oilfield sewage. ANAL SCI 2024; 40:1031-1041. [PMID: 38642247 DOI: 10.1007/s44211-024-00506-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2023] [Accepted: 01/04/2024] [Indexed: 04/22/2024]
Abstract
The development of advanced functional nanomaterials for solid-phase microextraction (SPME) remains an imperative aspect of sample pretreatment. Herein, we introduce a novel SPME fiber consisting of graphene fibers modified with ordered mesoporous carbon nanotubes arrays (CNTAs) tailored for the determination of benzene series in oilfield wastewater, which is synthesized by an ionic liquid-assisted wet spinning process of graphene nanosheets, followed by a precisely controlled growth of metal-organic framework and subsequent pyrolysis treatment. The resulting robust microfiber structure resembles a "hairbrush" configuration, with a crumpled graphene fiber "stem" and high-order mesoporous CNTAs "hairs". This unique architecture significantly enhances the SPME capacity, as validated by gas chromatography-mass spectrometry. The hairbrush-like nanocarbon assembled microfibers possess structural characteristics, a high specific surface area, and numerous binding sites, offering efficient enrichment of benzene series compounds in oilfield wastewater, including benzene, ethylbenzene, m-xylene, p-xylene, and toluene. Our analysis demonstrates that these microfibers exhibit broad linear ranges (0.2-600 μg L-1), low detection limits (0.005-0.03 mg L-1), and excellent repeatability (3.2-5.5% for one fiber, 2.1-6.7% for fiber-to-fiber) for detection. When compared to commercial alternatives, these hairbrush-like nanocarbon-assembled microfibers exhibit significantly enhanced extraction efficiency for benzene series compounds.
Collapse
|
6
|
Rapid screening of drugs in environmental water using metal organic framework/Ti 3C 2T x composite coated blade spray-mass spectrometry. JOURNAL OF HAZARDOUS MATERIALS 2024; 472:134609. [PMID: 38759280 DOI: 10.1016/j.jhazmat.2024.134609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Revised: 05/11/2024] [Accepted: 05/11/2024] [Indexed: 05/19/2024]
Abstract
Simultaneous rapid screening of multiple drugs of abuse in environmental water facilitates effective monitoring and trend assessments. Herein, a novel porphyrin-based metal organic frameworks modified Ti3C2Tx nanosheets (Cu-TCPP/Ti3C2Tx) composite was prepared and utilized as solid-phase microextraction (SPME) coating for the simultaneous analysis of 21 drugs from water samples. The composite was embedded with matrix-compatible polyacrylonitrile binder to prepare a coated blade with thin and uniform coating layer. Ambient mass spectrometry (MS) technique was used to create a coated blade spray-MS (CBS-MS) method for the quantitative determination of drugs in water samples. High throughput and automated sample preparation were achieved with the use of a Concept 96-well plate system, enabling analysis of 21 drugs of abuse within 1 min per sample, while using only 8 µL of organic solvent for desorption and CBS-MS detection. The developed method showed favorable linearity (R2 ≥ 0.9983) in the range of 0.05 to 10 ng mL-1, low limits of detection (1.5-9.0 ng L-1), sufficient recovery (67.6-133.2%), as well as satisfactory precision (RSDs≤13.5%). This study not only delivers a novel and efficient SPME coating composite, but also demonstrates the excellent performance of a high-throughput, efficient, and green analytical method for determination of drugs in environmental water.
Collapse
|
7
|
Ultra-thin FeCoNi-LDH hollow nanoflower as solid-phase microextraction coating for targeted capture of six pesticides by electrostatic adsorption. Talanta 2024; 276:126258. [PMID: 38776772 DOI: 10.1016/j.talanta.2024.126258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2024] [Revised: 05/05/2024] [Accepted: 05/12/2024] [Indexed: 05/25/2024]
Abstract
Pesticides are common pollutants that cause detriment to the ecological environmental safety and health of human due to their toxicity, volatility and bioaccumulation. In this work, an ultra-thin polymetallic layered double hydroxide (FeCoNi-LDH) with hollow nanoflower structure composite was synthesized using ZIF-67 as a self-sacrificial template, which was used as solid-phase microextraction (SPME) coating for the targeted capture pesticides, which could be combined with high-performance liquid chromatography (HPLC) to sensitive inspection pesticides in real water samples. Orthogonal experimental design (OAD) was applied to ensure the best SPME condition. Additionally, the adsorption properties were evaluated by chemical thermodynamics and kinetics. Under the optimized conditions, high adsorption capacity was obtained (117.0-21.5 mg g-1). A wide linear range (0.020-1000.0 μg L-1), low detection limit (0.008-0.172 μg L-1) and excellent reproducibility were obtained under the established method. This research provided a new strategy for designing hollow materials with multiple cations for the adsorption of anion or organic pollutants.
Collapse
|
8
|
Rapid and sensitive determination of legacy and emerging per- and poly-fluoroalkyl substances with solid-phase microextraction probe coupled with mass spectrometry. Talanta 2024; 276:126233. [PMID: 38739954 DOI: 10.1016/j.talanta.2024.126233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2024] [Revised: 05/04/2024] [Accepted: 05/07/2024] [Indexed: 05/16/2024]
Abstract
This study was designed to develop a rapid and sensitive method for quantifying legacy and emerging per- and polyfluoroalkyl substances (PFASs) in environmental samples with solid-phase microextraction (SPME) coupled with mass spectrometry (MS). An innovative SPME probe was fabricated via in situ polymerization, and the probe coating was optimized with response surface methodology to maximize the fluorine-fluorine interactions and electrostatic properties and ensure high selectivity for the target PFASs with enrichment factors of 48-491. The coupled SPME and MS provided a rapid and sensitive method for analyses of PFASs, with excellent linearity (r ≥ 0.9962) over the concentration range 0.001-1 μg/L and remarkably low detection limits of 0.1-13.0 ng/L. This method was used to analyze trace PFASs in tap water, river water, and wastewater samples and proved to be a simple and efficient analytical method for selective enrichment and detection of contaminants in the environment.
Collapse
|
9
|
Porous chlorine-functionalized covalent organic framework anchored graphene aerogel composite for synergically enhanced solid phase microextraction of polychlorinated naphthalene in environmental water. JOURNAL OF HAZARDOUS MATERIALS 2024; 469:133909. [PMID: 38432094 DOI: 10.1016/j.jhazmat.2024.133909] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 02/17/2024] [Accepted: 02/25/2024] [Indexed: 03/05/2024]
Abstract
The residues of polychlorinated naphthalenes (PCNs) produced in multiple industrial production and life processes are continuously entering environmental waters through atmospheric deposition and land drainage, and the water pollution caused by PCNs is continuing public concern due to their potential threat to aquatic ecosystems and public health. Herein, a new chlorine-functionalized covalent organic framework anchored graphene aerogel (COF-GA) was synthesized by covalent modification technology and used as fiber coating of solid-phase microextraction for synergically enhanced extraction of PCNs in environmental water. The extraction efficiency of COF-GA coated fiber was superior to commercial fiber due to the multiple interactions (π-π, hydrophobic interaction, and halogen bonding interaction). The COF-GA coated fiber has good stability, can avoid water vapor interference at 80 °C for a long time (30 -50 min) to maintain adsorption equilibrium, and can be reused at least 96 times. Combined with gas chromatography-tandem mass spectrometry, a sensitive method for the high-efficient enrichment (enrichment factors were 501 -7453 folds) and ultra-sensitive detection (LODs were 0.001 -0.428 pg/mL) of PCNs in environmental water was established. The enrichment factor for PCNs is significantly higher than in previous studies. This proposed method provides new technical support for the daily monitoring and risk assessment of trace PCNs in environmental water.
Collapse
|
10
|
Automated sequential SPME addressing the displacement effect in food samples. Food Chem 2024; 439:138093. [PMID: 38043285 DOI: 10.1016/j.foodchem.2023.138093] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 11/22/2023] [Accepted: 11/25/2023] [Indexed: 12/05/2023]
Abstract
The displacement effect can be an issue for the quantitation of analytes with low affinity towards the extraction phase in solid-phase microextraction (SPME) for food samples that have low level of binding matrix or high level of hydrophobic compounds. In this communication, automated sequential SPME-GC-MS strategy was developed for addressing the displacement issue. The SPME thin film with PDMS coating was firstly used for the extraction of hydrophobic components in the sample which cause displacement and then SPME fiber with DVB/CAR/PDMS coating was applied in the second step for the extraction of the remain compounds. This new strategy was investigated by using 10 key food odorants as target analytes and tested in commercial beer samples. The results suggested that sequential SPME can decrease the displacement effect and improve the extraction efficiency for polar analytes.
Collapse
|
11
|
Post-synthetic modification of covalent organic framework for efficient adsorption of organochlorine pesticides from cattle's milk. Food Chem 2024; 439:138182. [PMID: 38100880 DOI: 10.1016/j.foodchem.2023.138182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Revised: 11/24/2023] [Accepted: 12/06/2023] [Indexed: 12/17/2023]
Abstract
Analysis of organochlorine pesticides (OCPs) residues in milk faces a significant challenge. Herein, a sea urchin structured covalent organic framework bearing boric acid groups named COF-B(OH)2 was synthesized and applied as a coating material for solid-phase microextraction (SPME) of the OCPs in cattle's milk. Its performance was superior to that of three commonly used commercial SPME fibers, which could be due to the coexistence of hydrogen bonding, halogen bonding, π-stacking and electrostatic interactions. Besides, the fiber coating displayed good stability and reusability. After optimization, a COF-B(OH)2 based SPME coupled with gas chromatography-electron capture detection was established for the sensitive detection of the OCPs from milk samples. The limits of detection (S/N = 3) were between 0.04 and 1.00 μg kg-1. Satisfactory accuracy was achieved with the method recoveries in the range of 87.5 % to 112.5 %. These results manifest the feasibility of the COF-B(OH)2 coated fiber for the enrichment of the trace OCPs from milk samples.
Collapse
|
12
|
Metabolomic and lipidomic landscape of porcine kidney associated with kidney perfusion in heart beating donors and donors after cardiac death. Transl Res 2024; 267:79-90. [PMID: 38052298 DOI: 10.1016/j.trsl.2023.12.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Revised: 10/23/2023] [Accepted: 12/01/2023] [Indexed: 12/07/2023]
Abstract
Transplant centers are currently facing a lack of tools to ensure adequate evaluation of the quality of the available organs, as well as a significant shortage of kidney donors. Therefore, efforts are being made to facilitate the effective use of available organs and expand the donor pool, particularly with expanded criteria donors. Fulfilling a need, we aim to present an innovative analytical method based on solid-phase microextraction (SPME) - chemical biopsy. In order to track changes affecting the organ throughout the entire transplant procedure, porcine kidneys were subjected to multiple samplings at various time points. The application of small-diameter SPME probes assured the minimal invasiveness of the procedure. Porcine model kidney autotransplantation was executed for the purpose of simulating two types of donor scenarios: donors with a beating heart (HBD) and donors after cardiac death (DCD). All renal grafts were exposed to continuous normothermic ex vivo perfusion. Following metabolomic and lipidomic profiling using high-performance liquid chromatography coupled to a mass spectrometer, we observed differences in the profiles of HBD and DCD kidneys. The alterations were predominantly related to energy and glucose metabolism, and differences in the levels of essential amino acids, purine nucleosides, lysophosphocholines, phosphoethanolamines, and triacylglycerols were noticed. Our results indicate the potential of implementing chemical biopsy in the evaluation of graft quality and monitoring of renal function during perfusion.
Collapse
|
13
|
Polyaniline-coated kapok fibers for convenient in-syringe solid-phase microextraction and determination of organochlorine and pyrethroid pesticide residues in aqueous samples. Talanta 2024; 271:125706. [PMID: 38280266 DOI: 10.1016/j.talanta.2024.125706] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2023] [Revised: 01/09/2024] [Accepted: 01/22/2024] [Indexed: 01/29/2024]
Abstract
Pesticides used in agriculture have low polarity and a tendency to accumulate in fatty tissues, posing potential risks to human health. Effective pre-treatment is crucial due to complex sample matrices and low concentrations of pesticide residues typically encountered in instrument analysis. In this study, polyaniline-coated kapok fiber (PANI-KF) was synthesized successfully using in-situ oxidative polymerization for use as sorbents in in-syringe SPME of pyrethroid pesticides (PYRs) and organochlorine pesticides (OCPs) from aqueous samples. Coating the natural KF with PANI maintained the hollow microtubular structure and fiber morphology while significantly enhancing the extraction efficiency. The extraction process was easily conducted by simply pulling and pushing the syringe plunger. The entire extraction process, utilizing 3 mg of PANI-KF, could be completed in approximately 3 min. Density functional theory results indicated that the adsorption mechanism of PANI-KF towards OCPs and PYRs mainly involved van der Waals interactions, π-π interactions, and weak hydrogen bonding interactions. With the coupling of gas chromatography-mass spectrometry, a quantification method was established that exhibited good linearities (R2 > 0.990), and relative recoveries (87.2-108.5 %). The limits of detection ranged from 0.4 to 2.0 ng mL-1 and the matrix effects were negligible (-12.3-16.4 %). The validated in-syringe SPME-GC-MS method was successfully applied to determine pesticide residues in fruit juices, oral liquids and herbal extract granules with satisfactory accuracy and precision. PANI-KF exhibits remarkable promise as a sorbent for the extraction and enrichment of pesticide residues in aqueous samples, thereby contributing to the advancement of pesticide residue determination methodologies.
Collapse
|
14
|
In situ fabrication of covalent organic frameworks on solid-phase microextraction probes coupled with electrospray ionization mass spectrometry for enrichment and determination of androgens in biosamples. Mikrochim Acta 2024; 191:276. [PMID: 38644435 DOI: 10.1007/s00604-024-06355-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Accepted: 04/05/2024] [Indexed: 04/23/2024]
Abstract
Solid-phase microextraction (SPME) coupled with electrospray ionization mass spectrometry (ESI-MS) was developed for rapid and sensitive determination of endogenous androgens. The SPME probe is coated with covalent organic frameworks (COFs) synthesized by reacting 1,3,5-tri(4-aminophenyl)benzene (TPB) with 2,5-dioctyloxybenzaldehyde (C8PDA). This COFs-SPME probe offers several advantages, including enhanced extraction efficiency and stability. The analytical method exhibited wide linearity (0.1-100.0 µg L-1), low limits of detection (0.03-0.07 µg L-1), high enrichment factors (37-154), and satisfactory relative standard deviations (RSDs) for both within one probe (4.0-14.8%) and between different probes (3.4-12.7%). These remarkable performance characteristics highlight the reliability and precision of the COFs-SPME-ESI-MS method. The developed method was successfully applied to detect five kinds of endogenous androgens in female serum samples, indicating that the developed analytical method has great potential for application in preliminary clinical diagnosis.
Collapse
|
15
|
Layered double hydroxide nanoparticles for a smartphone digital image colorimetry-based determination of fluoride ions in water, milk and dental products. Food Chem 2024; 438:137999. [PMID: 37979264 DOI: 10.1016/j.foodchem.2023.137999] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2023] [Revised: 11/06/2023] [Accepted: 11/12/2023] [Indexed: 11/20/2023]
Abstract
A novel smartphone digital image colorimetry-based approach was developed for fluoride ion determination, using layered double hydroxide (LDH) nanoparticles (Mg2Al(OH)7) as sorbents for analyte preconcentration and as a source of a central metal ion for a colored complex formation. A cotton rotating disk provided effective retention of the LDH nanoparticles during solid-phase microextraction and elution, excluding time-consuming centrifugation process. In the proposed procedure, the nanoparticles acted as aluminum ion source for alizarin complexone-Al3+-F- complex formation. An image of Eppendorf tube, containing the colored complex solution was obtained by a smartphone and converted, using the RGB model for fluoride ion determination. The procedure had a linear range of 0.20-20 mg L-1 with a limit of detection of 0.06 mg L-1. The developed procedure provided effective fluoride separation from various matrices for its determination by a smartphone without additional sample pretreatment.
Collapse
|
16
|
Controlled construction of 2D hierarchical core-shell ZnO/MnO 2 nanosheets on Nitinol fiber with enhanced adsorption performance for selective solid-phase microextraction of trace polycyclic aromatic hydrocarbons in water samples. Anal Chim Acta 2024; 1298:342402. [PMID: 38462331 DOI: 10.1016/j.aca.2024.342402] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2023] [Revised: 02/02/2024] [Accepted: 02/21/2024] [Indexed: 03/12/2024]
Abstract
BACKGROUND Polycyclic aromatic hydrocarbons (PAHs) are an important class of potentially toxic persistent organic pollutants in environmental water. Their concentrations are usually too low to allow for direct determination with analytical instruments, and the preconcentration is required prior to instrumental analysis. Solid phase microextraction (SPME) is considered as a high-performance green sample preparation technique for volatile and non-volatile organic compounds due to its high enrichment factor. In fact, the nature of SPME coatings governs the adsorption performance. Therefore, more efforts have devoted to the controlled construction of novel long-life SPME fibers with enhanced adsorption performance and improved adsorption selectivity. RESULTS 2D hierarchical core-shell ZnO/MnO2 nanosheets (NSs) were constructed on a Nitinol (NiTi) fiber substrate by layer-by-layer assembly for enhanced and selective SPME of PAHs. Firstly, hexagonal ZnO NSs were electrodeposited on the NiTi substrate. Subsequently smaller secondary MnO2 NSs were uniformly grown on the surface of ZnO NSs by a facile hydrothermal oxidation process. ZnO NSs were well protected by the chemically stable MnO2 shell, making the coating highly durable and efficient for SPME application. Meanwhile, the ZnO/MnO2 NSs coating demonstrated superior adsorption performance for PAHs. After the optimization of SPME conditions, the proposed SPME-HPLC-UV method exhibited good analytical performance for preconcentrating and determining trace PAHs with wide linear ranges (0.03-200 μg L-1) and low LODs (0.005-0.112 μg L-1) as well as good repeatability (1.4%-6.9%) and fiber-to-fiber reproducibility (5.3%-7.1%). Moreover, the proposed method showed good precision and recovery in the preconcentration and determination of target PAHs in real water samples. SIGNIFICANCE As compared with representative commercially available fibers, the NiTi@ZnO/MnO2 NSs fiber showed enhanced adsorption efficiency and improved adsorption selectivity for PAHs. The constructed fiber can be used as an alternative to commercial fibers for the adsorption and preconcentration of target PAHs in the environmental water samples. Moreover, the preparation strategy is expected to provide new insights into the precisely controlled construction of the efficient and stable core-shell bimetallic oxide nanostructures on the superielastic NiTi-based fibers.
Collapse
|
17
|
A functionalized glass fiber as the adsorbent for efficient analysis of endocrine disruptors in aqueous environments. J Chromatogr A 2024; 1720:464813. [PMID: 38490142 DOI: 10.1016/j.chroma.2024.464813] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 03/04/2024] [Accepted: 03/11/2024] [Indexed: 03/17/2024]
Abstract
Estrogens and bisphenols are typical endocrine disruptors (EDs) that pose a potential hazard to the human body due to their widespread presence in aqueous environments. In this study, a β-cyclodextrin porous crosslinked polymer (β-CD-PCP) was prepared in-situ on a glass fiber surface by a nucleophilic substitution reaction. An effective and sensitive solid phase microextraction method using functionalized glass fiber with β-CD-PCP coating as the adsorbent was established for the detection of 11 EDs in a water environment. The β-CD-PCP was in-situ prepared on a glass fiber surface by a nucleophilic substitution reaction. The β-CD-PCP successfully separated five estrogens (ESTs) and six bisphenols (BPs) through hydrophobic and π-π interactions. The conditions affecting extraction were optimized. Under the optimized conditions, the ESTs obtained a high enrichment effect (1795-2328), low limits of detection (0.047 µg L-1) and a good linearity range (0.2-15.0 µg L-1). Furthermore, the spiked recoveries of analyte ESTs in aqueous environments were between 82.9-115.7 %. The results indicated that the prepared functionalized glass fibers exhibited good adsorption properties, and the established analytical method was reliable for monitoring trace ESTs and BPs in aqueous environments.
Collapse
|
18
|
Solid-phase microextraction coupled to comprehensive multidimensional gas chromatography for food analysis. Anal Bioanal Chem 2024; 416:2221-2246. [PMID: 37999723 DOI: 10.1007/s00216-023-05048-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 10/22/2023] [Accepted: 11/09/2023] [Indexed: 11/25/2023]
Abstract
Solid-phase microextraction and comprehensive multidimensional gas chromatography represent two milestone innovations that occurred in the field of separation science in the 1990s. They have a common root in their introduction and have found a perfect coupling in their evolution and applications. This review will focus on food analysis, where the paradigm has changed significantly over time, moving from a targeted analysis, focusing on a limited number of analytes at the time, to a more holistic approach for assessing quality in a larger sense. Indeed, not only some major markers or contaminants are considered, but a large variety of compounds and their possible interaction, giving rise to the field of foodomics. In order to obtain such detailed information and to answer more sophisticated questions related to food quality and authenticity, the use of SPME-GC × GC-MS has become essential for the comprehensive analysis of volatile and semi-volatile analytes. This article provides a critical review of the various applications of SPME-GC × GC in food analysis, emphasizing the crucial role this coupling plays in this field. Additionally, this review dwells on the importance of appropriate data treatment to fully harness the results obtained to draw accurate and meaningful conclusions.
Collapse
|
19
|
Recent advances in the use of SPME for drug analysis in clinical, toxicological, and forensic medicine studies. Talanta 2024; 270:125613. [PMID: 38159351 DOI: 10.1016/j.talanta.2023.125613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 12/21/2023] [Accepted: 12/27/2023] [Indexed: 01/03/2024]
Abstract
Solid-phase microextraction (SPME) has gained attention as a simple, fast, and non-exhaustive extraction technique, as its unique features enable its use for the extraction of many classes of drugs from biological matrices. This sample-preparation approach consolidates sampling and sample preparation into a single step, in addition to providing analyte preconcentration and sample clean-up. These features have helped SPME become an integral part of several analytical protocols for monitoring drug concentrations in human matrices in clinical, toxicological, and forensic medicine studies. Over the years, researchers have continued to develop the SPME technique, resulting in the introduction of novel sorbents and geometries, which have resulted in improved extraction efficiencies. This review summarizes developments and applications of SPME published between 2016 and 2022, specifically in relation to the analysis of central nervous system drugs, drugs used to treat cardiovascular disorders and bacterial infections, and drugs used in immunosuppressive and anticancer therapies.
Collapse
|
20
|
A novel top-down strategy for in situ construction of vertically oriented hexagonal NiCr LDHs nanosheet arrays with intercalated sulfate ions on Nichrome fiber for selective solid-phase microextraction of phenolic compounds in water samples. Anal Chim Acta 2024; 1296:342339. [PMID: 38401931 DOI: 10.1016/j.aca.2024.342339] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 01/31/2024] [Accepted: 02/04/2024] [Indexed: 02/26/2024]
Abstract
BACKGROUND Phenolic compounds (PCs) are a class of polar aromatic pollutants with high toxicity in environmental water. Generally the efficient sample preparation is essential for the quantification of ultra-trace target PCs in real water sample before appropriative instrumental analysis. SPME is a convenient, solvent-free and time-saving miniaturized technique and has been recognized as a green alternative to conventional extraction techniques. In SPME, however, commercial fused-silica fibers are limited to the fragility, operation temperature, extraction capacity and selectivity as well as lifetime. Therefore, the development of new SPME fibers is always needed to overcome such limitations. RESULTS We presented a novel top-down strategy for in situ construction of vertically oriented hexagonal sulfate intercalated NiCr layered double hydroxide nanosheet arrays (NiCr LDHs-SO4 NSAs) on the Nichrome (NiCr) substrate by hydrothermal treatment in NaOH solution containing (NH4)2S2O8. The results showed that much shorter hydrothermal time was needed for the construction of NiCr@NiCr LDHs-SO4 NSAs fiber in the presence of (NH4)2S2O8. Moreover, the unique NiCr LDHs-SO4 NSAs coating offered open access structure, and thereby more available surface area for adsorption. The resulting fiber exhibited better extraction efficiency for phenolic compounds (PCs), faster mass transfer rate, higher mechanical stability, and longer service life than original NiCr@NiCr LDHs NSs fiber and typical commercially fused-silica fibers. After optimizing conditions, the SPME-HPLC-UV method demonstrated a linear range from 0.05 μg L-1 to 200 μg L-1 with LODs of 0.015-0.156 μg L-1 (S/N = 3) and LOQs of 0.048-0.498 μg L-1 (S/N = 10), as well as good repeatability (3.06%-5.22%) and fiber-to-fiber reproducibility (4.32%-6.49%). SIGNIFICANCE The developed SPME-HPLC-UV method with the constructed fiber was applied to the preconcentration and detection of different types of PCs in real water samples, showing satisfactory recoveries ranging from 86.20% to 107.8% with RSDs of 3.18%-6.69%. This study provides a new strategy for in situ construction of bimetallic hydroxides and their derived nanocomposite coatings on the NiCr fiber substrate in practical SPME application.
Collapse
|
21
|
Extraction of volatile organic compounds liberated upon filament extrusion by 3D pen and its comparison with a desktop 3D printer using solid-phase microextraction fiber and Arrow. J Chromatogr A 2024; 1719:464740. [PMID: 38401373 DOI: 10.1016/j.chroma.2024.464740] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2023] [Revised: 02/12/2024] [Accepted: 02/13/2024] [Indexed: 02/26/2024]
Abstract
Desktop 3D printers that operate by the fused deposition modeling (FDM) mechanism are known to release numerous hazardous volatile organic compounds (VOCs) during printing, including some with potential carcinogenic effects. Operating in a similar manner to FDM 3D printers, 3D pens have gained popularity recently from their ability to allow users to effortlessly draw in the air or create various 3D printed shapes while handling the device like a pen. In contrast to numerous modern 3D printers, 3D pens lack their own ventilation systems and are often used in settings with minimum airflow. Their operation makes users more vulnerable to VOC emissions, as the released VOCs are likely to be in the breathing zone. Consequently, monitoring VOCs released during the use of 3D pens is crucial. In this study, VOCs liberated while extruding acrylonitrile butadiene styrene (ABS) filaments from a 3D pen were measured by solid-phase microextraction (SPME) combined with gas chromatography/mass spectrometry (GC/MS). SPME was investigated using the traditional fiber and Arrow geometries with the DVB/Carbon WR/PDMS sorbent while four different brands of ABS filaments-Amazon Basics, Gizmodork, Mynt 3D, and Novamaker-were used with the 3D pen. Heatmap analysis showed differentiation among these brands based on the liberated VOCs. The nozzle temperature and printing speed were found to affect the number and amount of released VOCs. This study goes a step further and presents for the first time a comparison between 3D pen and a desktop 3D printer based on liberated VOCs. Interestingly, the findings reveal that the 3D pen releases a greater number and amount of VOCs compared to the printer. The amounts of liberated VOCs, as indicated by the corresponding chromatographic peak areas, were found to be 1.4 to 62.6 times higher for the 3D pen compared to the 3D printer when using SPME Arrow.
Collapse
|
22
|
Silver nanoparticle-functionalized melamine-formaldehyde aerogel for online in-tube solid-phase microextraction of polycyclic aromatic hydrocarbons followed by HPLC-DAD analysis. J Chromatogr A 2024; 1719:464767. [PMID: 38422709 DOI: 10.1016/j.chroma.2024.464767] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 02/14/2024] [Accepted: 02/21/2024] [Indexed: 03/02/2024]
Abstract
Based on the π-metal interaction between silver nanoparticles (AgNPs) and aromatic compounds, AgNPs were in-situ grown to melamine-formaldehyde (MF) aerogel for improving the extraction performance to polycyclic aromatic hydrocarbons (PAHs). The AgNPs/MF aerogel was regulated through varing the concentration of reactants, and characterized by scanning electron microscopy, X-ray photoelectron spectroscopy and X-ray powder diffraction. As a new extraction coating, the AgNPs/MF aerogel was coated to stainless-steel wires for in-tube solid-phase microextraction (IT-SPME). The extraction effects of MF aerogels before and after the modification of AgNPs were compared, and the AgNPs greatly improved the extraction ability for PAHs reaching to 166.4 %. Combining IT-SPME with high performance liquid chromatographic detection, an online analytical system was constructed. Furthermore, the sampling volume and rate, concentration of organic solvent, and desorption time were optimized factor by factor. The online analytical method with low detection limits (0.003-0.010 μg L-1) and efficient enrichment factors (1998-3237) for PAHs was established, which fastly detected trace level of PAHs in drinking and environmental water samples. Compared with other methods, the method was comparable or better in the detection limit and linear range, indicating prospective application of the AgNPs/MF aerogel for sample preparation.
Collapse
|
23
|
Imprinted covalent organic frameworks solid-phase microextraction fiber for in vivo monitoring of acidic per- and polyfluoroalkyl substances in live aloe. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 918:170645. [PMID: 38320695 DOI: 10.1016/j.scitotenv.2024.170645] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/22/2023] [Revised: 01/30/2024] [Accepted: 01/31/2024] [Indexed: 02/10/2024]
Abstract
Per- and polyfluoroalkyl substances (PFASs) can lead to risks associated with animal and human health through the transfer along food chains. It is confirmed that PFASs can be transported to each part of plants after taken up by the roots. To better elucidate the underlying mechanisms for such exposure, it is highly valuable to develop analytical capabilities for in vivo monitoring of PFASs in live plants. In this work, a novel imprinted covalent organic frameworks (CMIP) solid-phase microextraction coupled with ultra-performance liquid chromatography-tandem mass spectrometry was developed with low limits of detection for six acidic PFASs (0.1-0.3 ng g-1) and used for in vivo monitoring in live aloe. The CMIP coating shows good precision (RSD of intra and inter ≤9.6 % and 10.2 %, respectively) and possesses much higher extraction efficiency than the commercial coatings. After cultivating aloe in soil spiked PFASs, the in vivo assays gave a wealth of information, including steady-state concentrations, translocation factors, elimination rate constants, and half-life of PFASs. The in vivo tracing method for live plants can provide much needed and unique information to evaluate the risk of PFASs, which are very important for the safety of agriculture production.
Collapse
|
24
|
Enhancing the water-resistance of MOF-199 film through incorporation of microporous organic networks for solid-phase microextraction of BTEX in aqueous environments with improved efficiency. Anal Chim Acta 2024; 1294:342293. [PMID: 38336414 DOI: 10.1016/j.aca.2024.342293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 01/03/2024] [Accepted: 01/26/2024] [Indexed: 02/12/2024]
Abstract
BACKGROUND The practical application of moisture sensitive metal organic frameworks (MOFs) in extraction technology faces challenges related to competitive adsorption and water stability. The target analytes cannot be effectively extracted under humid conditions due to the competitive moisture adsorption and/or framework structure collapse of MOFs. In this study, the microporous organic networks (MONs) were synthesized through Sonogashira coupling reaction to use for hydrophobic modification on the surface of MOF-199. RESULTS The MOF-199@MON as coating was deposited on stainless steel wires for solid-phase microextraction (SPME) of benzene series (BTEX) in aqueous environments. Under the optimal extraction conditions, the MOF-199@MON coated fiber for SPME coupled with GC-MS for the determination of BTEX gave the linear range of 0.5-500 μg L-1, the limit of detections (LODs, S/N = 3) of 0.01-0.04 μg L-1, the limit of quantifications (LOQs, S/N = 10) of 0.04-0.12 μg L-1, the enhancement factors of 3567-4878, and the intra-day, inter-day and fiber-to-fiber precisions (relative standard deviations, RSDs) of 1.0-9.8, 1.9-7.9 and 4.5-9.5 %, respectively. The developed method was successfully applied to the analysis of BTEX in water samples with the recoveries of 71.0 %-113 %. SIGNIFICANCE This work reveals the home-made SPME fibers have a long service life (the extraction efficiency of fiber decreased by only 7.26 %-13.14 % after 100 cycles). The potential of MON functionalized MOFs as effective adsorbents for the SPME of pollutants in the water environment.
Collapse
|
25
|
Evaluation of deep eutectic solvents in the synthesis of molecularly imprinted fibers for the solid-phase microextraction of triazines in soil samples. Anal Bioanal Chem 2024; 416:1337-1347. [PMID: 38308710 PMCID: PMC10861628 DOI: 10.1007/s00216-024-05164-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 01/11/2024] [Accepted: 01/17/2024] [Indexed: 02/05/2024]
Abstract
Nowadays, molecularly imprinted polymers (MIPs) are well established and are considered excellent materials for performing selective extractions. However, with the progressive implementation of the principles of green chemistry, it is necessary to find greener alternatives for both the synthesis and further use of MIPs in sample preparation. Accordingly, in the present work, different deep eutectic solvents (DES, both hydrophilic and hydrophobic), as an alternative to conventional organic solvents (i.e., toluene), were evaluated as porogens for the synthesis of imprinted fibers (monoliths), using fused silica capillaries as molds, for solid-phase microextraction (SPME). From this study, the polymer prepared with propazine (dummy template), methacrylic acid (monomer), ethylene glycol dimethacrylate (cross-linker), and a formic acid:L-menthol (1:1) DES (porogen) showed the best performance for selective rebinding of triazines. After optimization of the different variables involved in SPME, the new imprinted fibers were successfully applied to the extraction of target analytes (desisopropylatrazine, desethylatrazine, simazine, and atrazine) from soil sample extracts, providing relative recoveries ranging from 75.7 to 120.1%, reaching limits of detection within the range of 6.2-15.7 ng g-1, depending upon the analyte.
Collapse
|
26
|
Quantitative determination of amphetamine-type stimulants in sewage and urine by hybrid monolithic column solid-phase microextraction coupled with UPLC-QTRAP MS/MS. Talanta 2024; 269:125437. [PMID: 38070282 DOI: 10.1016/j.talanta.2023.125437] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Revised: 10/24/2023] [Accepted: 11/17/2023] [Indexed: 01/05/2024]
Abstract
A needle-solid-phase microextraction (SPME) method based on hybrid monolithic column (HMC) was proposed for simultaneous separation and extraction of seven amphetamine-type stimulants (ATSs) (amphetamine, methamphetamine, cathinone, methcathinone, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxymethamphetamine, and 3,4-methylenedioxyethylamphetamine), combining with ultra-performance liquid chromatography-triple quadrupole/linear ion trap mass spectrometer (UPLC-QTRAP MS/MS). Thiol functionalized HMC (T-HMC) showed high extraction efficiency and excellent elution results towards target analytes, among three kinds of single/bi-functionalized HMCs. Various parameters of SPME operation and analytical performance were investigated systematically. The adsorption mechanism of T-HMC to ATSs was also discussed and explained as a mixed mode of electrostatic and hydrophobic interactions. Under the optimum experimental conditions, the proposed T-HMC needle-SPME-UPLC-QTRAP MS/MS method was rapid and convenient with good accuracy, low sample consumption, high sensitivity and strong anti-interference ability. This method was successfully applied to quantitative determination of seven trace ATSs in complex sewage and urine samples. In view of abundant types of HMCs, the needle-SPME based on functional HMC also had the potential to selectively separating and enriching other tract new psychoactive substances in complex matrices, and could provide a reliable tool for drug monitoring, especially in applications for forensic analysis and drug abuse.
Collapse
|
27
|
Perspective on SPME-MS: Green and high-performance methods for rapid screening. Anal Chim Acta 2024; 1291:342244. [PMID: 38280787 DOI: 10.1016/j.aca.2024.342244] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Revised: 12/30/2023] [Accepted: 01/12/2024] [Indexed: 01/29/2024]
Abstract
The direct coupling of solid-phase microextraction (SPME) with mass spectrometry (MS) offers rapid analysis with high sensitivity and low matrix effects by benefiting from the integration of sampling, high enrichment, and clean-up functions of SPME. Eliminating chromatographic separation reduces the amount of gas/solvent needed for analysis, while direct desorption in SPME-MS consumes none or few microliters of organic solvents per sample, further enhancing the greenness of the SPME technology. Over the past two decades, the rapid evolution of SPME-MS has given rise to numerous novel technologies that employ diverse ionization techniques and interfaces, several of which have already been commercialized. Drawing from an extensive review published earlier this year and our research experience, we provide perspectives on three aspects of these technologies: interface design and automation, integration with state-of-art MS instrumentation, and anticipated future developments.
Collapse
|
28
|
Quantification of prohibited substances and endogenous corticosteroids in saliva using traditional, alternative microextraction-based, and novel 3D printed sample-preparation methods coupled with LC-MS. Anal Chim Acta 2024; 1291:342236. [PMID: 38280791 DOI: 10.1016/j.aca.2024.342236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Revised: 01/06/2024] [Accepted: 01/09/2024] [Indexed: 01/29/2024]
Abstract
Oral fluid has gained significant interest as an alternative matrix for drug testing due to its easy and non-invasive collection. Despite these advantages, achieving suitably low limits of detection remains a clear challenge in the use of oral fluids for drug screening. In this study, we demonstrate that the application of commercially available SPME fibers followed by liquid chromatography tandem mass spectrometry can enable the comprehensive detection and confirmation of drugs in oral fluid samples. To this end, we develop and test a sample-preparation protocol for a panel of 46 drugs covering the most popular drugs of abuse and doping agents available worldwide. Human saliva samples were collected using a Salivette® device (CE IVD certified) and sampled using SPME devices coated with a C18 extraction phase. The proposed protocol was validated with respect to its lower limits of quantification (LLOQ), linearity, matrix effects, precision, and extraction recovery. Linearity was confirmed for all compounds (R2 > 0.97), except for testosterone (R2 = 0.953) and metandrostenolon (R2 = 0.958). Furthermore, 4 compounds suffered from matrix effects, with less than 10 % deviation from acceptance criteria. After analytical validation, saliva samples from volunteers were analyzed to determine free concentrations of cortisol at different times after awaking. Finally, a 3D-printed prototype device was designed and successfully applied to extract small molecules, thus demonstrating a new modern low-cost approach for bioanalysis.
Collapse
|
29
|
Sea-urchin-like covalent organic framework as solid-phase microextraction fiber coating for sensitive detection of trace pyrethroid insecticides in water. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 912:169129. [PMID: 38097077 DOI: 10.1016/j.scitotenv.2023.169129] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2023] [Revised: 11/30/2023] [Accepted: 12/03/2023] [Indexed: 12/19/2023]
Abstract
Pyrethroid insecticides residues in water pose a critical threat to the environment from widespread production and overuse. Therefore, it is of major relevance to develop a sensitive and efficient method to detect pyrethroid insecticides in water. In this paper, a covalent organic framework (COF) with NHCO as the structural unit was synthesized using a simple condensation reaction of TTL (NH2) and TDBA (COOH). Various characterization results and density functional theory (DFT) calculations demonstrated that multiple interactions synergistically promoted the adsorption of pyrethroid insecticides on COFTDBA-TTL. Based on the excellent extraction capability of COFTDBA-TTL, efficient detection of 11 pyrethroid insecticides in water was achieved using COFTDBA-TTL-coated SPME fiber and gas chromatography-tandem mass spectrometry (GC-MS). The results showed that the extraction enhancement factors (EFs) of pyrethroid insecticides were as high as 2584-7199, and the extraction efficiencies were 3.28-446 times higher than that of commercial fiber, which reflected its high adsorption property. Meanwhile, the limits of detection (LODs) of the COFTDBA-TTL coated fiber were as low as 0.170-1.68 ng/L under the optimal conditions, and the recoveries of 11 pyrethroid insecticides in the actual water samples were 88.5-108 %. In conclusion, the SPME-GC-MS method based on COFTDBA-TTL coated fiber was simple, rapid, and efficient, and should have a promising application in trace detection of pyrethroid insecticides in the environment.
Collapse
|
30
|
Analytical methods for detecting butane, propane, and their metabolites in biological samples: Implications for inhalant abuse detection. J Chromatogr B Analyt Technol Biomed Life Sci 2024; 1234:124011. [PMID: 38277722 DOI: 10.1016/j.jchromb.2024.124011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2023] [Revised: 12/28/2023] [Accepted: 01/10/2024] [Indexed: 01/28/2024]
Abstract
Worldwide, various inhalants are widely abused for recreational purposes, with butane and propane emerging as among the most commonly misused volatile substances, posing a significant risk of sudden death. The rapid elimination and oxidation of these highly volatile compounds upon inhalation necessitate the identification of butane and propane along with their metabolites in biological samples. Hence, the primary objective of this study is twofold: firstly, to establish a method for analyzing butane, propane, and metabolites, and secondly, to demonstrate the detection window and exposure indicators associated with the inhalation of butane and propane. In pursuit of this objective, we developed analytical methods for the determination of isobutane, n-butane, propane, and their nine metabolites in both blood and urine. Headspace-gas chromatography-mass spectrometry (GC-MS) and solid-phase microextraction-GC-MS were employed for the analyses, demonstrating acceptable precision and accuracy. An animal study revealed that isobutane and n-butane were only detectable below the limit of quantification (LOQ) in rat blood 5 min after exposure. Meanwhile, the three major metabolites-2-methyl-2-propanol, 2-butanol, and 2-butanone-were observed 5 min after exposure but persisted in rat urine even 5 h post-exposure. Additionally, human urine samples identified other metabolites, including acetone, acetoin, and 2,3-butanediol isomers. The presence of specific metabolites corresponding to each inhalant confirmed the abuse of butane and propane. This comprehensive approach provides valuable insights into the detection and assessment of inhalation to these volatile substances.
Collapse
|
31
|
Recent progress of covalent organic frameworks as attractive materials for solid-phase microextraction: A review. Anal Chim Acta 2024; 1287:341953. [PMID: 38182358 DOI: 10.1016/j.aca.2023.341953] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2023] [Revised: 10/20/2023] [Accepted: 10/21/2023] [Indexed: 01/07/2024]
Abstract
Solid-phase microextraction (SPME) is a green, environmentally friendly, and efficient technique for sample pre-treatment. Covalent organic frameworks (COFs), a class of porous materials formed by covalent bonds, have gained prominence owing to their remarkable attributes, including large specific surface area, tunable pore size, and robust thermal/chemical stability. These characteristics have made COFs highly appealing as potential coatings for SPME fiber over the past decades. In this review, various methods used to prepare SPME coatings based on COFs are presented. These methods encompass physical adhesion, sol-gel processes, in situ growth, and chemical cross-linking strategies. In addition, the applications of COF-based SPME coating fibers for the preconcentration of various targets in environmental, food, and biological samples are summarized. Moreover, not only their advantages but also the challenges they pose in practical applications are highlighted. By shedding light on these aspects, this review aims to contribute to the continued development and utilization of COF materials in the field of sample pretreatment.
Collapse
|
32
|
Highly graphitized porous carbon/reduced graphene oxide for ultrahigh enrichment and ultrasensitive determination of polycyclic aromatic hydrocarbons. JOURNAL OF HAZARDOUS MATERIALS 2024; 462:132699. [PMID: 37827103 DOI: 10.1016/j.jhazmat.2023.132699] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 09/22/2023] [Accepted: 10/01/2023] [Indexed: 10/14/2023]
Abstract
There is an urgent need to develop efficient and reliable coating materials for solid phase microextraction (SPME), in order to quantify and monitor pollutants in environmental waters. Herein, a highly graphitized porous carbon/reduced graphene oxide (PC/rGO) was successfully synthesized by pyrolysis of metal organic framework/graphene oxide precursors, and used as a SPME coating for ultrahigh enrichment of polycyclic aromatic hydrocarbons (PAHs) from water. The as-prepared PC/rGO exhibited high degree of graphitization, abundant number of micro/mesopores along with exceptional thermal stability, making it an ideal SPME coating material. The PC/rGO fiber offered an ultrahigh enrichment factor for PAHs (up to 126057), which could be attributed to the multiple interactions between the PC/rGO and PAHs, including hydrophobic and π-π interactions, partitioning, and mesopore filling effect. In the analysis of PAHs, the PC/rGO fiber showed a wide linearity (0.007-100 ng mL-1), low limits of detection (0.0005-0.005 ng mL-1), and good repeatability (RSDs <10.1%, n = 5) under optimized conditions. The established method was applicable for ultrasensitive determination of PAHs in different environmental waters and showed satisfactory recoveries. This study provides a novel way for constructing thermally stable SPME coating having efficient extraction performance.
Collapse
|
33
|
Green, mildly synthesized bismuth-based MOF for extraction of polar glucocorticoids in environmental water. JOURNAL OF HAZARDOUS MATERIALS 2024; 461:132477. [PMID: 37716268 DOI: 10.1016/j.jhazmat.2023.132477] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2023] [Revised: 08/26/2023] [Accepted: 09/02/2023] [Indexed: 09/18/2023]
Abstract
The complex sample matrix and low environmental concentration make it challenging to effectively determine the polar glucocorticoids. In particular, a green, economical, and environmentally friendly method is urgently needed, since a large amount of extraction solvents, samples, and extraction materials have been commonly used to improve the sensitivity of the reported methods. In this study, a green and robust phenol and bismuth-based MOF of SU101 was mildly synthesized and fabricated as a brand new solid-phase microextraction (SPME) fiber. Only tiny amounts of SU101 and desorption solvents were employed to realize the high-efficiency enrichments of glucocorticoids from water samples. The detection performance of proposed SU101 fiber towards glucocorticoids was much superior to the single-component and multi-component commercial fibers. It indicated that SU101 fiber could be an excellent candidate for the enrichments of polar pharmaceuticals. After it was coupled with the instrument of high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS), the linear range of 5-10000 ng L-1 with detection limits low to 0.070-1.5 ng L-1 and satisfactory recoveries were achieved by the developed method. Benefiting from the environmental friendliness of SU101 and the less-solvent consumption of SPME technique, this work presented a green and economical strategy for determinations of trace glucocorticoids.
Collapse
|
34
|
Exposure and risk assessment of phthalates in environmental water using a three-template molecularly imprinted fiber array strategy. JOURNAL OF HAZARDOUS MATERIALS 2024; 461:132491. [PMID: 37717442 DOI: 10.1016/j.jhazmat.2023.132491] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 08/18/2023] [Accepted: 09/04/2023] [Indexed: 09/19/2023]
Abstract
Phthalate is a kind of environmental estrogen having a reproductive toxicity effect on animals and plants in the environment, and its detection is prone to matrix interference. Nevertheless, the molecularly imprinted polymer (MIP) can resist matrix interference. A three-template MIP solid-phase microextraction fiber array technique with improved adsorption flux and extraction capacity was innovatively developed. Additionally, the three-template MIP fiber arrays were used to screen phthalates in environmental water. The result showed that the three-template MIP fiber array had great potential for monitoring and controlling phthalate in environmental water. Moreover, the enrichment factors of the three-template MIP fiber arrays were 1410.65, 2419.55, and 493.21 times those of PA, PDMS, and PDMS/DVB commercial fiber-constructed arrays, respectively. The risk assessment using risk quotient revealed that BBP and DPHP had a medium-high ecological risk, DMP had a medium-low ecological risk, while EP and BP had a minimal ecological risk. This strategy represents an effective, easily tailored, and reusable method to simultaneously enhance extraction capacity and adsorption flux. It is environmentally friendly and has great feasibility for specific recognition of phthalate from environmental water and ecological risk assessment.
Collapse
|
35
|
Poly(ionic liquid)s threaded into covalent organic framework for synergistic capture of polybrominated diphenyl ethers. JOURNAL OF HAZARDOUS MATERIALS 2024; 461:132657. [PMID: 37788553 DOI: 10.1016/j.jhazmat.2023.132657] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2023] [Revised: 08/27/2023] [Accepted: 09/26/2023] [Indexed: 10/05/2023]
Abstract
The efficient enrichment of trace polybrominated diphenyl ethers (PBDEs) in environmental waters remains challenging for environmental monitoring and analysis. Herein, a covalent organic frameworks-poly(ionic liquid)s hybrid material (COF-γ-PIL) is synthesized by threading poly(1-vinyl-3-methylimidazolium bis ((trifluoromethyl) sulfonyl) imide) into a vinyl-decorated COF via photopolymerization. The resultant hybrid retains the crystallinity and porosity of COF, thus offering adequate adsorption sites for the targets. PIL threaded in COF facilitates the synergistic capture of target molecules within the hybrid through multiple interactions, including Van der Waals forces, weak hydrogen bonding, and hydrophobic interactions. As a proof of concept, COF-γ-PIL was utilized as the fiber coating for SPME of PBDEs in waters prior to their analysis via GC-MS. Excellent analytical results were achieved, with wide linearity (0.01-100 ng L-1), low limits of detection (0.0021-0.014 ng L-1), and satisfactory recoveries (78.6%-103.6%). The outstanding extraction performance can be ascribed to the extraordinary flexibility of the active fraction on linear polymers threaded in COF, which facilitates collaborative capture for target molecules, as revealed by density functional theory (DFT) calculations. This work uncovers the microscopic mechanism for PBDEs capturing and provides new insights into the design of functionalized COF hybrids.
Collapse
|
36
|
Volatile/semi-volatile metabolites profiling in living vegetables via a novel covalent triazine framework based solid-phase microextraction fiber coupled with GC-QTOF-MS. Food Chem 2024; 430:137064. [PMID: 37549619 DOI: 10.1016/j.foodchem.2023.137064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Revised: 07/26/2023] [Accepted: 07/29/2023] [Indexed: 08/09/2023]
Abstract
An in vivo solid-phase microextraction (SPME) fiber with high-coverage capture capacity of plant endogenous substances based on the porous covalent triazine framework (CTF) material was developed. The CTF fiber coupled with gas chromatographic quadrupole time-of-flight mass spectrometer (GC-QTOF-MS) analysis was used for monitoring untargeted endogenous metabolites in living Chinese cabbage plants (Brassica campestris L. ssp. chinensis Makino (var. communis Tsen et Lee)). A total of 100 endogenous substances were identified, mainly including aldehydes, ketones, acids, alcohols, phenols, alkanes, alkenes, esters, isorhodanates, nitriles, as well as indole and its derivatives. Using the in vivo metabolites analysis method, Chinese cabbage plants at different growing stages demonstrated significantly statistical differences in plant metabolism. In addition, metabolic dysregulation of Chinese cabbage plants under fipronil pesticide contamination was observed. To summarize, the proposed approach provides a feasible method to capture metabolic information in living vegetables and for risk assessment of pesticide use during agricultural production.
Collapse
|
37
|
Nanoleaf-derived carbon materials as a sensitivity coating for solid‑phase microextraction of polycyclic aromatic hydrocarbons. Anal Bioanal Chem 2024; 416:277-285. [PMID: 37946033 DOI: 10.1007/s00216-023-05016-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 10/15/2023] [Accepted: 10/19/2023] [Indexed: 11/12/2023]
Abstract
Metal-organic framework-derived carbon materials have shown extensive application in the sensitive extraction of polycyclic aromatic hydrocarbons (PAHs), but more active sites for its adsorption were still a tireless pursuit. In this study, ZIF-nanoleaf-derived carbon (NLCs) was synthesized and developed as a solid-phase microextraction (SPME) fiber (NLCs-F). The extraction performance was compared with ZIF-dodecahedron-derived carbon (DHCs) coated fiber (DHCs-F), which was prepared by only changing the ratio of the reactants. The unique morphology of NLCs provided abundant adsorption active sites for the selected PAHs, while the large average aperture facilitated selective extraction of high molecular weight analytes. Additionally, the high carbon content enhanced the strong enrichment capability for hydrophobic PAHs. Hence, the prepared NLCs-F coupled with GC-MS showed a good correlation coefficient (0.9975) in a wide linear range, low limits of detection (0.3-1.8 ng L-1), satisfactory repeatability, and reproducibility, which made it apply in the enrichment of PAHs in actual tea and coffee samples.
Collapse
|
38
|
Impacts of seasonality, drought, nitrogen fertilization, and litter on soil fluxes of biogenic volatile organic compounds in a Mediterranean forest. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 906:167354. [PMID: 37774858 DOI: 10.1016/j.scitotenv.2023.167354] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/07/2023] [Revised: 09/06/2023] [Accepted: 09/23/2023] [Indexed: 10/01/2023]
Abstract
Biogenic volatile organic compounds (BVOCs) play critical roles in ecosystems at various scales, influencing above- and below-ground interactions and contributing to the atmospheric environment. Nonetheless, there is a lack of research on soil BVOC fluxes and their response to environmental changes. This study aimed to investigate the impact of drought, nitrogen (N) fertilization, and litter manipulation on soil BVOC fluxes in a Mediterranean forest. We assessed the effects of drought and N fertilization on soil BVOC exchanges and soil CO2 fluxes over two consecutive years using a dynamic chamber method, and solid-phase microextraction was utilized to quantify soil BVOCs in one year. Our findings revealed that the soil acted as an annual net sink for isoprenoids (1.30-10.33 μg m-2 h-1), with the highest uptake rates observed during summers (25.90 ± 9.36 μg m-2 h-1). The increased summer uptake can be attributed to the significant concentration gradient of BVOCs between atmosphere and soil. However, strong seasonal dynamics were observed, as the soil acted as a source of BVOCs in spring and autumn. The uptake rate of isoprenoids exhibited a significant positive correlation with soil temperature and atmospheric isoprenoid concentrations, while displaying a negative correlation with soil moisture and soil CO2 flux. The effects of drought and N fertilization on soil BVOCs were influenced by the type of VOCs, litter layer, and season. Specifically, drought significantly affected the exchange rate and quantities of sesquiterpenes. N fertilization led to increased emissions of specific BVOCs (α-pinene and camphene) due to the stimulation of litter emissions. These findings underscore the importance of the soil as a sink for atmospheric BVOCs in this dry Mediterranean ecosystem. Future drought conditions may significantly impact soil water content, resulting in drier soils throughout the year, which will profoundly affect the exchange of soil BVOCs between the soil and atmosphere.
Collapse
|
39
|
Zinc oxide-aluminum oxide nanocomposite solid phase microextraction for diazepam and oxazepam trace determination. J Chromatogr B Analyt Technol Biomed Life Sci 2024; 1232:123966. [PMID: 38104432 DOI: 10.1016/j.jchromb.2023.123966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2023] [Revised: 11/22/2023] [Accepted: 12/08/2023] [Indexed: 12/19/2023]
Abstract
A new efficient ZnO-Al2O3 nanocomposite (ZANC) was synthesized to form solid-phase microextraction (SPME) fiber. The prepared fiber was used for trace determination of benzodiazepines by gas chromatography-flame ionization detector in urine samples. The effective parameters on the extraction process including extraction time, salt percentage, desorption time and sample pH were optimized by a factorial design method. The method was evaluated at the optimum conditions and limits of detection (LODs) were calculated 20 µg/L for diazepam and oxazepam. The method repeatability for oxazepam and diazepam (50 µg/L, n = 4) was calculated at 8.8 % and 6.4 %. Also, the method reproducibility was obtained, 7.45 % and 6.61 % for oxazepam and diazepam (50 µg/L, n = 4). Also, fiber-to-fiber relative standard deviation (RSDs%) for the target analytes were less than 15.5 %. The method linearity is within the range of 62-500 µg/L for diazepam and oxazepam. The ZANC-SPME fiber showed a good lifetime (60 times) with high chemical stability. The high thermal stability of ZANC-SPME fiber was attained at 280 °C. The extraction results of poly dimethylsiloxan/divinyl benzene (PDMS/DVB) fiber were compared by ZANC-SPME fiber. Therefore, the method is proposed as a suitable technique for benzodiazepines detection in the urine sample.
Collapse
|
40
|
Optimum drying conditions for ginger ( Zingiber officinale Roscoe) based on time, energy consumption and physicochemical quality. Food Chem X 2023; 20:100987. [PMID: 38144724 PMCID: PMC10740043 DOI: 10.1016/j.fochx.2023.100987] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Revised: 10/13/2023] [Accepted: 11/06/2023] [Indexed: 12/26/2023] Open
Abstract
The effect of ultrasonic pre-treatment on moisture removal characteristics of ginger in a convective dryer was investigated. The slabs were dried by practicing sonication durations of 0, 15 and 30 min at different levels of the air temperature and velocity. Following increasing the sonication duration and air temperature, required time and energy to dehydrate the samples were decreased. The pre-treatment played important role in improving rehydration capability and surface color retention in the dried gingers. Content of the main volatile component (α-Zingiberene) was not influenced by the sonication. Mean values for the phenolic contents and antioxidant activity at sonication duration of 0, 15 and 30 min were determined to be 18.93, 18.15 and 17.49 GAE/g dry matter and 83.57, 78.33 and 74.58 %, respectively. The desired values for the temperature, velocity and sonication duration were revealed to be about 66 °C, 3 m/s and 20 min, respectively.
Collapse
|
41
|
Selective extraction of phospholipids from human milk using glass fabric modified with zirconium-based metal organic framework. J Chromatogr A 2023; 1710:464435. [PMID: 37820461 DOI: 10.1016/j.chroma.2023.464435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Revised: 09/30/2023] [Accepted: 10/05/2023] [Indexed: 10/13/2023]
Abstract
Phospholipids (PLs) are important and complex trace lipids in milk, which have positive effects on the infants' nervous and immune system development. Herein, a new method for selective extraction of PLs using glass fabric @ MOF-808 was proposed. Based on Lewis acid-base interaction, MOF-808 containing abundant Zr-OH groups was selected as the adsorption body, and glass fabric was used as a substrate to make the adsorbent easy to remove and reuse. The influencing factors such as loading solution, extraction time, eluent and elution time were further investigated. The adsorbent showed high adsorption capacity (3.31-6.54 mg/g for PLs) and good reusability (reused at least five times). The method showed low detection limits (1.61 μg/L - 10.24 μg/L) and quantification limits (5.24 μg/L-51.21 μg/L) for eight classes of PLs. The analysis of PLs in human milk at different lactation stages by ultra-high performance liquid chromatography-quadrupole time-of-flight mass spectrometry could obtain up to 206 PLs, indicating that the method has extremely high extraction and anti-interference capabilities. This work is the first time to introduce MOF materials to selectively extract PLs and use glass fabric as a substrate for MOF-808, which has the advantages of easy recovery and high sensitivity. It provides technical support for the discovery of more PL species and has potential applications in phospholipidomics.
Collapse
|
42
|
Metal-organic frameworks as solid-phase microextraction adsorbents for the determination of triacetone triperoxide by gas chromatography-mass spectrometry. Forensic Sci Int 2023; 352:111852. [PMID: 37839179 DOI: 10.1016/j.forsciint.2023.111852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2023] [Revised: 09/22/2023] [Accepted: 09/29/2023] [Indexed: 10/17/2023]
Abstract
Triacetone triperoxide (TATP) is a high-power explosive which is often used by criminals. The detection of TATP is of great significance for solving the explosion cases. However, the preconcentration and analysis of trace levels of TATP still pose challenges for analytical researchers. In this study, metal-organic frameworks (MOFs), including IRMOF-8, MOF-5, UIO-66, ZIF-8, and MIL-101(Cr), were immobilized on a stainless steel wire using a physical adhesive method as a solid-phase microextraction (SPME) fiber coating. The prepared fibers with a controllable thickness were used for the extraction of TATP followed by gas chromatography-mass spectrometry (GC-MS) analysis. Under the identical experimental conditions, the IRMOF-8-coated fiber exhibited higher extraction efficiency for TATP than the other fibers. The IRMOF-8-coated fiber was then characterized using scanning electron microscopy and thermogravimetric analysis. The results indicated that the IRMOF-8-coated fiber not only had good thermal and chemical stabilities but also afforded a high TATP extraction efficiency. Under the same extraction conditions, the extraction efficiency of the IRMOF-8-coated fiber was 2-8 times higher than those of commercial fibers. The limit of detection was 13 ng/mL, and linearity was observed in the range of 50-5000 ng/mL with a correlation coefficient greater than 0.998. The intraday repeatability (n = 6), interday repeatability (n = 3), and fiber-to-fiber reproducibility (n = 3), were 4.1 %, 4.8 %, and 8.0 %, respectively. The recoveries of TATP from the simulated tap water and soil samples were 87.32-90.57 % and 88.76-100.93 %, respectively, with relative standard deviations lower than 11.11 % (n = 3). The above method was successfully applied for the detection of TATP transferred from a finger to a paper surface, demonstrating its good application prospects in the analysis of trace TATP.
Collapse
|
43
|
TiO 2@COF-based solid-phase microextraction combined with UHPLC-MS/MS for the rapid determination of potential biomarkers of phosphatidylcholines and lysophosphatidylcholines in head and neck cancers. Anal Bioanal Chem 2023; 415:6771-6783. [PMID: 37776352 DOI: 10.1007/s00216-023-04954-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 09/07/2023] [Accepted: 09/13/2023] [Indexed: 10/02/2023]
Abstract
Phosphatidylcholine (PC) and lysophosphatidylcholine (LPC), two types of phospholipids (PLs), have been reported to be closely correlated with head and neck cancers of laryngeal cancer (LC) and thyroid cancer (TC), which make their analysis crucial. TiO2@COF-based solid-phase microextraction (SPME) coupled to UHPLC-MS/MS was developed for the rapid and accurate detection of seven potential PL biomarkers from small amounts of serum in this work. The combination of TiO2 and COF proves to be effective for the extraction of the target analytes. Under optimal conditions, the developed TiO2@COF-based SPME-UHPLC-MS/MS method revealed good linearity (R2 ≥ 0.997) with LODs ranging from 0.05 to 0.38 ng/mL for PLs, the extraction recoveries and matrix effects ranging from 83.09-112.03% and 85.38-113.67%, respectively. As a high-throughput pretreatment method, satisfactory probe-to-probe reproducibility rates of 2.7-10.1% were obtained. Finally, the TiO2@COF-based SPME-UHPLC-MS/MS method was applied to analyze LPC 14:0, LPC 16:0, LPC 18:0, LPC 18:1, LPC 19:0, PC 16:0/18:1, and PC 18:0 in serum samples from early LC patients (n = 15), early TC patients (n = 15), and healthy volunteers (n = 15). The results indicated that cancer patients could be effectively differentiated from healthy controls using orthogonal partial least squares discriminant analysis (OPLS-DA). In conclusion, the established TiO2@COF-based SPME-UHPLC-MS/MS method is reliable for the rapid determination of the seven PLs in serum samples, which is promising for early diagnosis of head and neck cancers.
Collapse
|
44
|
Nanoporous carbon fiber derived from Cu-BDC metal organic framework @pencil graphite as a sorbent for solid phase microextraction of acetamiprid and imidacloprid. Anal Chim Acta 2023; 1278:341650. [PMID: 37709423 DOI: 10.1016/j.aca.2023.341650] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2023] [Revised: 07/14/2023] [Accepted: 07/15/2023] [Indexed: 09/16/2023]
Abstract
Solid-phase microextraction (SPME) is a sample pretreatment technique for enrichment of trace level of compounds from complex matrices. The fiber coating, as an extraction phase, is the significant part of SPME, which specifying the analytical performance of the developed SPME. In this study, a novel in situ fabricated Cu@porous carbon fiber that derived from copper benzene-1,4-dicarboxylate framework@pencil graphite (Cu-BDC MOF@PG) fiber was prepared as a SPME fiber. The Cu-BDC MOF was electrodeposited on the surface of pencil graphite. The Cu@porous carbon fiber with nanoporous structure was constructed by the direct carbonization of the electrosynthesized fiber. The Cu@porous carbon fiber showed high analytical performance for direct immersion SPME (DI-SPME) of acetamiprid and imidacloprid in fruit and vegetable samples. The SPME method was coupled by high-performance liquid chromatography-ultraviolet detection (SPME-HPLC-UV) for determination of the analytes. Under the optimized condition, good linear ranges (1-500 μg L-1 and 0.5-200 μg L-1) and acceptable limits of detection (LODs = 0.30 and 0.15 μg L-1), appropriate spiking recoveries in the range 87-109.0% were attained for acetamiprid and imidacloprid, respectively. Intra- and inter-day relative standard deviations were found within the ranges of 2.35-3.46% and 3.30-3.70%, respectively. These results signify promising potential of the in situ fabricated porous carbon fiber for SPME applications. Considering that most of the pencil graphite is made of carbon, after the carbonization of the Cu-BDC MOF@PG fiber, a unified porous carbon fiber is obtained. Compared to other reported procedures, in situ direct carbonization of Cu-BDC MOF@PG fiber was a one-step and straightforward method to fabricate carbon fiber.
Collapse
|
45
|
Preparation of black phosphorus nanosheets/ zeolitic imidazolate framework nanocomposite for high-performance solid-phase microextraction of organophosphorus pesticides. J Chromatogr A 2023; 1708:464339. [PMID: 37660557 DOI: 10.1016/j.chroma.2023.464339] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 08/07/2023] [Accepted: 08/27/2023] [Indexed: 09/05/2023]
Abstract
Design and preparation of new fiber coatings for solid-phase microextraction (SPME) is of significance to the sample preparation techniques. Herein, a facile strategy has been developed for the integration of the black phosphorus (BP) nanosheets with metal-organic framework (ZIF-8) to generate a BP/ZIF-8 nanocomposite. For the first time, the newly-synthesized BP/ZIF-8 nanocomposite was adopted as the SPME fiber coating for the extraction of organophosphorus pesticides (OPPs). Under the optimized conditions, the BP/ZIF-8 based SPME method gained acceptable linearity (0.04-20 µg L-1), low limits of detection (0.012-0.051 µg L-1) and good repeatability (3.2-8.1%). Coupled with gas chromatography-mass spectrometric detection, the developed SPME method was successfully used for the preconcentration of OPPs from environmental waters with the method recoveries from 92.0%-103.8%. This method offers a good alternative for the analysis of trace OPPs in environmental water samples.
Collapse
|
46
|
In vivo solid phase microextraction for therapeutic monitoring and pharmacometabolomic fingerprinting of lung during in vivo lung perfusion of FOLFOX. J Pharm Anal 2023; 13:1195-1204. [PMID: 38024854 PMCID: PMC10657970 DOI: 10.1016/j.jpha.2023.04.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2022] [Revised: 04/04/2023] [Accepted: 04/08/2023] [Indexed: 12/01/2023] Open
Abstract
In vivo lung perfusion (IVLP) is a novel isolated lung technique developed to enable the local, in situ administration of high-dose chemotherapy to treat metastatic lung cancer. Combination therapy using folinic acid (FOL), 5-fluorouracil (F), and oxaliplatin (OX) (FOLFOX) is routinely employed to treat several types of solid tumours in various tissues. However, F is characterized by large interpatient variability with respect to plasma concentration, which necessitates close monitoring during treatments using of this compound. Since plasma drug concentrations often do not reflect tissue drug concentrations, it is essential to utilize sample-preparation methods specifically suited to monitoring drug levels in target organs. In this work, in vivo solid-phase microextraction (in vivo SPME) is proposed as an effective tool for quantitative therapeutic drug monitoring of FOLFOX in porcine lungs during pre-clinical IVLP and intravenous (IV) trials. The concomitant extraction of other endogenous and exogenous small molecules from the lung and their detection via liquid chromatography coupled to high resolution mass spectrometry (LC-HRMS) enabled an assessment of FOLFOX's impact on the metabolomic profile of the lung and revealed the metabolic pathways associated with the route of administration (IVLP vs. IV) and the therapy itself. This study also shows that the immediate instrumental analysis of metabolomic samples is ideal, as long-term storage at -80 °C results in changes in the metabolite content in the sample extracts.
Collapse
|
47
|
SPME as a green sample-preparation technique for the monitoring of phytocannabinoids and endocannabinoids in complex matrices. J Pharm Anal 2023; 13:1117-1134. [PMID: 38024858 PMCID: PMC10657972 DOI: 10.1016/j.jpha.2023.06.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2023] [Revised: 06/10/2023] [Accepted: 06/27/2023] [Indexed: 12/01/2023] Open
Abstract
The endocannabinoid system (ECS), particularly its signaling pathways and ligands, has garnered considerable interest in recent years. Along with clinical work investigating the ECS' functions, including its role in the development of neurological and inflammatory conditions, much research has focused on developing analytical protocols enabling the precise monitoring of the levels and metabolism of the most potent ECS ligands: exogenous phytocannabinoids (PCs) and endogenous cannabinoids (endocannabinoids, ECs). Solid-phase microextraction (SPME) is an advanced, non-exhaustive sample-preparation technique that facilitates the precise and efficient isolation of trace amounts of analytes, thus making it appealing for the analysis of PCs and ECs in complex matrices of plant and animal/human origin. In this paper, we review recent forensic medicine and toxicological studies wherein SPME has been applied to monitor levels of PCs and ECs in complex matrices, determine their effects on organism physiology, and assess their role in the development of several diseases.
Collapse
|
48
|
Biochar nanosphere-functionalized carbon fibers for in-tube solid-phase microextraction of polycyclic aromatic hydrocarbons in environmental water followed by liquid chromatography and diode array detection. Mikrochim Acta 2023; 190:395. [PMID: 37715796 DOI: 10.1007/s00604-023-05982-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Accepted: 09/01/2023] [Indexed: 09/18/2023]
Abstract
In order to improve the extraction ability of carbon fibers (CFs) for microextraction of polycyclic aromatic hydrocarbons (PAHs), biochar nanospheres derived from glucose were in-situ grown onto the surface of CFs via hydrothermal synthesis. The surface morphology and elemental composition of biochar nanospheres-CFs were investigated by scanning electron microscopy and X-ray photoelectron spectroscopy. Thereafter, the biochar nanosphere-CFs were pulled into the polyetheretherketone tube for solid-phase microextraction, and the tube was combined with high-performance liquid chromatography-diode array detector to online detect PAHs. With the help of π-stacking, hydrophobic, and hydrophilic effect of biochar nanospheres, the extraction efficiency of CFs was greatly enhanced (enrichment factor increased by 293% compared with the original). The conditions affecting the analytical performance (sampling volume, sampling rate, methanol content, and desorption time) were investigated. Under the optimal conditions, an online analytical method for microextraction and determination of several PAHs was developed, and satisfactory results were achieved. The limits of detection were 0.003-0.010 ng mL-1 owing to high enrichment effect (2973-3600), linearity ranged from 0.010-15.0 ng mL-1, and relative standard deviations were 0.4%-1.6% (intra-day) and 2.4%-4.4% (inter-day), respectively. The method was applied to analyze environmental water samples (rain water, snow water, and river water), and spiked recoveries within 80.0%-119% were obtained.
Collapse
|
49
|
Understanding the influence of polymeric ionic liquid sorbent coating substituents on cannabinoid and pesticide affinity in solid-phase microextraction. J Chromatogr A 2023; 1706:464222. [PMID: 37523907 DOI: 10.1016/j.chroma.2023.464222] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 07/04/2023] [Accepted: 07/18/2023] [Indexed: 08/02/2023]
Abstract
To understand factors that drive pesticide-cannabinoid selectivity in solid-phase microextraction (SPME), eight new polymeric ionic liquid (PIL) sorbent coatings were designed and compared to four previously reported PIL sorbent coatings for the extraction of pesticides. The four PIL sorbent coatings consisted of either vinylimidazolium or vinylbenzylimidazolium ILs with long alkyl chain substituents (i.e., -C8H17 or -C12H25) and bis[(trifluoromethyl)sulfonyl]imide ([NTf2-]) anions, from which the eight new PIL sorbent coatings were adapted. Modifications to the chemical structure of IL monomers and crosslinkers included incorporation of polymerizable p-styrenesulfonate or 3-sulfopropyl acrylate anions, the addition of aromatic moieties, and/or the addition of polar functional groups (i.e., -OH or -O- groups). A total of ten commonly regulated pesticides and six cannabinoids were examined in this study. The effect of salt on the solubility of pesticides and cannabinoids in aqueous solutions was assessed by determining their extraction efficiencies in the presence of varied methanol content. Differences in their solubilities appear to play a dominant role in enhancing pesticide-cannabinoid selectivity. The selectivity, represented as the ratio of pesticide total peak areas to cannabinoid total peak areas, also exhibited a moderate correlation to the affinity of the sorbent coatings towards both the pesticides and the cannabinoids. A positive correlation was observed for the pesticides and a negative correlation was observed for the cannabinoids, suggesting that selectivity was driven by more than the presence of salt in the samples. The sorbent coatings' affinity towards each class of analytes were examined to determine specific interactions that might influence selectivity. The two main structural modifications increasing pesticide-cannabinoid selectivity included the absence of aromatic moieties and the addition of hydrogen bond donor functional groups. Extractions of simple aromatic molecules as probes were performed under similar extraction conditions as the cannabinoids and confirmed the influence of hydrogen bonding interactions on sorbent coating affinity.
Collapse
|
50
|
Application of solid-phase microextraction arrows for characterizing volatile organic compounds from 3D printing of acrylonitrile-styrene-acrylate filament. J Chromatogr A 2023; 1705:464180. [PMID: 37393779 DOI: 10.1016/j.chroma.2023.464180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 05/28/2023] [Accepted: 06/25/2023] [Indexed: 07/04/2023]
Abstract
3D printing is an extensively used manufacturing technique that can pose specific health concerns due to the emission of volatile organic compounds (VOC). Herein, a detailed characterization of 3D printing-related VOC using solid-phase microextraction-gas chromatography/mass spectrometry (SPME-GC/MS) is described for the first time. The VOC were extracted in dynamic mode during the printing from the acrylonitrile-styrene-acrylate filament in an environmental chamber. The effect of extraction time on the extraction efficiency of 16 main VOC was studied for four different commercial SPME arrows. The volatile and semivolatile compounds were the most effectively extracted by carbon wide range-containing and polydimethyl siloxane arrows, respectively. The differences in extraction efficiency between arrows were further correlated to the molecular volume, octanol-water partition coefficient, and vapour pressure of observed VOC. The repeatability of SPME arrows towards the main VOC was assessed from static mode measurements of filament in headspace vials. In addition, we performed a group analysis of 57 VOC classified into 15 categories according to their chemical structure. Divinylbenzene-polydimethyl siloxane arrow turned out to be a good compromise between the total extracted amount and its distribution among tested VOC. Thus, this arrow was used to demonstrate the usefulness of SPME for the qualification of VOC emitted during printing in a real-life environment. A presented methodology can serve as a fast and reliable method for the qualification and semi-quantification of 3D printing-related VOC.
Collapse
|