1
|
Application of therapeutic ultrasonic waves across the dialyzer membrane: A pilot study on the impact on dialyzer clearance and safety. Hemodial Int 2024. [PMID: 38783838 DOI: 10.1111/hdi.13161] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 03/27/2024] [Accepted: 05/11/2024] [Indexed: 05/25/2024]
Abstract
INTRODUCTION Progressive clogging of the dialyzer membrane during hemodialysis can compromise solute removal efficiency. Existing solutions fall short in addressing intradialytic reduction of dialyzer clearance. This pilot study aims to assess the impact and safety of applying therapeutic ultrasonic waves to dialyzers for mitigating intradialytic clogging. METHODS In this pilot study, 15 stable maintenance hemodialysis patients (12 males and 3 females) were enrolled. Each patient served as their own control. They underwent one session of hemodialysis with the application of therapeutic ultrasonic waves (Ultrasonic session) and were crossed-over to a second session without the use of ultrasonic waves (Control session). All the study sessions operated at a fixed dialysate flow rate of 500 mL/min and a blood flow rate of 250 or 300 mL/min. The adequacy of dialysis achieved during each session was monitored using Online Clearance Monitoring of the dialysis machines, and clearance K values, varying between 135 and 209 mL/min, were recorded, and plotted. A direct comparison between Control and Ultrasonic sessions was performed to assess the impact and safety of using ultrasonic waves during hemodialysis. FINDINGS The mean percentage decline in dialyzer clearance values was 4.41% for Ultrasonic sessions (SD: 5.3) and 12.69% for Control sessions (SD: 6.35) (p-value <0.001). This indicates that the application of ultrasonic waves reduced the decline in clearance values. The mean differences of the blood component parameters were comparable between both Ultrasonic sessions and Control sessions, suggesting the safety of utilizing ultrasonic waves during dialysis. Microscopic membrane analysis corroborated the safety. DISCUSSION Intradialytic clogging of dialyzer membranes is a significant problem that can cause dialysis inadequacy. Our study tackles this issue by introducing therapeutic ultrasonic waves to improve dialyzer clearance during hemodialysis sessions in patients.
Collapse
|
2
|
Effect of needles distance of arteriovenous fistula cannulation on hemo dialysis adequacy based on KT/V: a randomized controlled trial. Ann Med Surg (Lond) 2024; 86:2739-2744. [PMID: 38694348 PMCID: PMC11060320 DOI: 10.1097/ms9.0000000000001966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Accepted: 03/04/2024] [Indexed: 05/04/2024] Open
Abstract
Background This study aims to assess the effect of needle distance of arteriovenous fistula (AVF) cannulation on haemodialysis adequacy based on KT/V. Materials and methods This study was a parallel-group, randomized controlled trial. Patients who met the inclusion criteria were divided into two groups with 3 and 6 cm needle distances using block randomization. Data acquisition transpired through a comprehensive checklist encompassing demographic variables such as age and sex, alongside clinical metrics comprising actual weight, dry weight, average dialysis duration, fistula longevity, and KT/V rate. Results A total of 42 haemodialysis patients were enroled in this investigation, with 21 allocated to the 3 cm needle distance group and another 21 to the 6 cm needle distance group. The mean post-haemodialysis KT/V values for the 3 cm and 6 cm needle distance groups were 1.25 (SD=0.25) and 1.42 (SD=0.24), respectively, demonstrating a statistically significant difference (P<0.001). While there was no significant difference in the average pre-haemodialysis and post-haemodialysis KT/V values within the 3 cm needle distance group (t=1.93, P=0.068), the corresponding values for the 6 cm needle distance group exhibited a notable discrepancy (t=9.66, P<0.001). Conclusion In general, a needle distance of 6 cm between arteriovenous points yielded superior enhancements in dialysis adequacy compared to a 3 cm needle distance following haemodialysis. Consequently, health administrators and policymakers may consider instituting efficacious interventions to scrutinize the care and therapeutic protocols for haemodialysis patients, involving the development of policies and applications.
Collapse
|
3
|
Relationship between symptom burden and dialysis adequacy in patients with chronic kidney disease undergoing hemodialysis. North Clin Istanb 2023; 10:435-443. [PMID: 37719249 PMCID: PMC10500242 DOI: 10.14744/nci.2023.01799] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2023] [Revised: 03/30/2023] [Accepted: 04/24/2023] [Indexed: 09/19/2023] Open
Abstract
OBJECTIVE The aim of this study was to reveal the relationship between hemodialysis (HD) adequacy and dialysis symptom index (DSI) in patients with end-stage kidney disease (ESKD). METHODS This prospective study included 92 ESKD patients who underwent HD three times a week. Data including sex, age, education status, marital status, economic status, employment status, dependency status, type of vascular access, and duration of HD were recorded. Biochemical and hematological analyses were carried out. Dialysis adequacy was assessed based on clinical and biochemical analysis. The DSI was used to evaluate the emotional and physical symptoms of HD patients. RESULTS Of the patients, 55 were males and 37 were females, with a mean age of 59.95±14.9 years. The median duration of HD was 60.0 months (interquartile range: 20.8-103.5). The mean DSI score was 54.35±26.0, with a significantly higher score in female patients (p<0.001). There was a significant correlation between DSI and increasing age (p<0.05). The single pool Kt/V (spKt/V) ratio of HD patients with AVF access was significantly higher, and the mean DSI was significantly lower than that of those receiving HD with a central venous catheter (p<0.001). The mean DSI score was significantly higher in patients with a spKt/V ratio of <1.2 than those with a spKt/V ratio of ≥1.2 (p<0.001). In multivariate regression analysis using biochemical parameters, the spKt/V ratio was a significant and independent predictor of DSI scores (R2=0.64, p<0.001). In addition, a significant and independent relationship was found between DSI and gender, age, and economic status in the regression analysis (R2=0.36, p<0.001). CONCLUSION Dialysis adequacy is an independent predictor of DSI. If an adequate dialysis dose is ensured to be delivered, symptom burden may dramatically decrease.
Collapse
|
4
|
Abstract
In recent years there has been an increasing interest in expanded hemodialysis (HDx), an emerging renal replacement therapy based on the use of medium cut-off membranes (MCO). Thanks to the internal architecture of these types of membranes, with a higher pore size and smaller fiber inner diameter to favor internal filtration rate, they can increase the removal of larger middle molecules in conventional hemodialysis. Secondarily, several reports suggest that this therapy potentially improve the outcomes for end-stage renal disease patients. However, HDx has not been defined yet and the characteristics of MCO membranes are not well stablished. The aim of this narrative review is to define HDx and summarize the dialyzers that have been used so far to perform this therapy, collect the evidence available on its efficacy and clinical outcomes compared with other hemodialysis techniques and settle the bases for its optimal prescription.
Collapse
|
5
|
Clinical performance comparison of two medium cut-off dialyzers. Ther Apher Dial 2023; 27:284-292. [PMID: 36858049 DOI: 10.1111/1744-9987.13919] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 08/02/2022] [Accepted: 08/05/2022] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Medium-cut-off (MCO) dialyzers may beneficially impact outcomes in patients on hemodialysis. METHODS In a randomized, controlled trial in maintenance hemodialysis patients, the new Nipro ELISIO-17HX MCO dialyzer was compared to the Baxter Theranova 400 filter regarding middle molecule removal. Furthermore, the suitability of two assays for free lambda-light chain (λFLC) detection (Freelite vs. N-Latex) was verified. RESULTS ELISIO-HX achieved slightly lower reduction ratios for β2 -microglobulin (71.8 ± 6.0 vs. 75.3 ± 5.8%; p = 0.001), myoglobin (54.7 ± 8.6 vs. 64.9 ± 8.7%; p < 0.001), and kappa-FLC (62.1 ± 8.8 vs. 56.3 ± 7.7%; p = 0.021). λFLC reduction ratios were more conclusive with the Freelite assay and not different between ELISIO-HX and Theranova (28.4 ± 3.9 vs. 38.7 ± 13.4%; p = 0.069). The albumin loss of Theranova was considerably higher (2.14 ± 0.45 vs. 0.77 ± 0.25 g; p = 0.001) and the Global Removal ScoreLoss alb largely inferior (30.6 ± 7.4 vs. 82.4 ± 29.2%/g; p = 0.006) to ELISIO-HX. CONCLUSIONS The new ELISIO-HX expands the choice of dialyzers for MCO hemodialysis.
Collapse
|
6
|
Effects of Exercise on Physiologic and Psychologic Outcomes in Patients with End Stage Kidney Disease on Hemodialysis: A Quasi-Experimental Study. Nephrol Nurs J 2023; 50:123-130. [PMID: 37074937] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/20/2023]
Abstract
End stage kidney disease (ESKD), a public health concern, has overwhelming effects on individuals' holistic wellbeing. Hemodialysis, albeit a life-saving treatment for patients with ESKD, can lead to muscle atrophy, weakness, and decreased quality of life mostly due to an inactive lifestyle. This quasi-experimental, pre-post design was used to study the effects of exercise on physiologic and psychologic outcomes of patients with ESKD at a hemodialysis unit in Lebanon. Patients acted as their own controls and were assessed before and after introducing the exercise program. Data were collected on quality of life of patients as well as their dialysis adequacy. Results showed that while there was a significant improvement in the dialysis adequacy post-exercise intervention, quality of life was not affected.
Collapse
|
7
|
Dialysis adequacy and hemoglobin levels predict cerebral atrophy in maintenance-hemodialysis patients. J Cereb Blood Flow Metab 2023; 43:882-892. [PMID: 36651130 DOI: 10.1177/0271678x231151621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
The pathogenesis of cerebral atrophy (CA) is not clear. Previous studies show a high incidence of preterm CA in hemodialysis patients. This study aims to investigate the factors influencing CA and to derive a CA prediction nomogram in maintenance-hemodialysis patients. First, brain volumes of hemodialysis patients (≤55 years) were compared against age- and sex-matched healthy controls, and differences were revealed in bilateral insular cisterns width, maximum cerebral sulci width, Evans index, ventricular-brain ratio, frontal atrophy index, and temporal lobe ratio. Then, the patients were divided equally into "no or mild" or "severe" CA groups. Potential factors influencing CA were screened. Kt/V (urea removal index) and hemoglobin levels negatively correlated with CA degree, and were used to establish a nomogram within randomly assigned training and validation patient groups. The areas under the receiver operating characteristic curves (AUROC) for training and validation groups were 0.703 and 0.744, respectively. When potassium and calcium were added to the nomogram, the AUROC for training/validation group increased to 0.748/0.806. The nomogram had optimal AUROC for training (0.759) and validation (0.804) groups when albumin was also included. Hemodialysis patients showed reduced anterior brain volumes and the nomogram established herein may have predictive value for developing CA.
Collapse
|
8
|
Effect of taurolidine citrate and unfractionated heparin on inflammatory state and dialysis adequacy in hemodialysis patients. J Vasc Access 2023; 24:45-51. [PMID: 34112001 DOI: 10.1177/11297298211023295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
BACKGROUND AND AIM HD patients using dialysis catheters have been associated with chronic inflammatory state. In Egypt 6.6% of HD patients use catheters, of which short term catheters represent 59.6% and 40.4% with long-term catheters. In this study, we aimed to assess the effect of Taurolidine citrate and unfractionated heparin combination (Taurolock-hep500™) as a lock solution compared to unfractionated heparin alone on inflammatory markers, incidence of catheter related blood stream infections (CRBSI) and dialysis adequacy in HD patients with temporary HD catheters only, for 4 weeks duration. METHODS Sixty ESRD patients from hemodialysis units in Ain-Shams University hospitals (ASUH) at the time of catheter insertion we enrolled in our study. They were randomized into two groups: Group 1: Thirty patients received Taurolock-hep500™ as a catheter lock solution at the end of each hemodialysis session. Group 2: Thirty patients received unfractionated heparin as a catheter lock solution. hsCRP and IL-6 were measured at baseline and 1 month after using the lock solutions. Blood cultures were done in patients who developed symptoms of catheter related infections. RESULTS At the end of the study, Inflammatory markers were significantly higher in group 2 (p-value: 0.045, 0.001, and 0.018 for WBCs, hsCRP and IL-6, respectively). Group 1 had better dialysis adequacy assessed by URR (p-value: 0.007 and 0.001, respectively). CRBSI were demonstrated in nine patients in group 2 (30%) in contrast to one patient only in group 1(3.3%) (p-value: 0.006) with pseudomonas being the most common isolated organism (27.7%). CONCLUSION Use of (Taurolock-hep500™) for temporary hemodialysis catheters was associated with lower levels of inflammation markers and lower incidence of CRBSI and better catheter performance.
Collapse
|
9
|
Effect of residual kidney function and dialysis adequacy on chronic pruritus in dialysis patients. Nephrol Dial Transplant 2022; 38:1508-1518. [PMID: 36549655 DOI: 10.1093/ndt/gfac341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Indexed: 12/24/2022] Open
Abstract
BACKGROUND Chronic Kidney Disease-associated pruritus (CKD-aP) is common in dialysis patients, associated with lower quality of life and increased risk of death. We investigated the association between residual eGFR, dialysis adequacy or serum phosphate level and CKD-aP in incident dialysis patients. METHODS 1256 incident hemodialysis (HD) and 670 peritoneal dialysis (PD) patients (>18y) from the Netherlands Cooperative Study on the Adequacy of Dialysis study were included (1997-2007) and followed until death, transplantation, or max 10y. CKD-aP was measured using a single item of the KDQOL-36. The associations were studied by logistic and linear regression analyses, adjusted for potential baseline confounders. RESULTS At baseline mean (SD) age was 60 (16), 62% were men and median (IQR) residual eGFR was 3.4 (1.7-5.3) ml/min/1.73m2. The prevalence of CKD-aP (∼70%) was similar in HD and PD. It was observed that 12 months after starting dialysis (after multivariable adjustment) each 1 ml/min/1.73m2 higher residual eGFR, one unit higher total weekly Kt/V, or 1 mmol/L lower serum phosphate level was associated with lower burden of CKD-aP in HD and PD patients of -0.05 (95%CI:-0.09;-0.02) and -0.09 (95%CI:-0.13;-0.05), -0.15 (95%CI:-0.26;-0.05) and -0.35 (95%CI:-0.54;-0.16), and of -0.34 (95%CI:-0.17;-0.51) and -0.45 (95%CI:-0.19;-0.71), respectively. We found no association between dialysis Kt/V and CKD-aP. CONCLUSIONS Higher residual eGFR and lower serum phosphate level, but not the dialysis dose, were related with lower burden of CKD-aP in dialysis patients.
Collapse
|
10
|
Comparison of measured vs kinetic-model predicted phosphate removal during hemodialysis and hemodiafiltration. Nephrol Dial Transplant 2022; 37:2522-2527. [PMID: 35869975 DOI: 10.1093/ndt/gfac223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2022] [Indexed: 12/31/2022] Open
Abstract
BACKGROUND To what extent hemodiafiltration (HDF) improves management of hyperphosphatemia over hemodialysis (HD) is a subject of ongoing investigation. METHODS We modified a previously described phosphate kinetic model to include incorporation of EUDIAL recommended equations for hemodiafiltration (HDF) clearance. We used the model to predict the recovery of phosphate from spent dialysate/hemofiltrate and compared this with averaged data from five published studies. Mean study average predialysis serum phosphate was 1.81 ± 0.20 mmol/L. Session length was close to 240 min per treatment. All HDF was done postdilution, at an average rate of 65 ± 24 mL/min. RESULTS Measured mean phosphate removal was 1039 ± 136 mg (33.5 ± 4.41 mmol, slightly lower than the model-predicted mean value of 1092 ± 127 mg (35.3 ± 4.09 mmol). The measured ratio of phosphate removal with HDF compared with HD averaged 1.15 ± 0.22, ranging from 1.01 to 1.44. Using mean study input parameters for patient size and treatment characteristics, the predicted ratio of phosphate removal with HDF compared with HD averaged 1.095 ± 0.029, ranging from 1.05 to 1.13. CONCLUSIONS Addition of EUDIAL-recommended convective clearance equations to a phosphate kinetic model predicts a 10% or greater benefit in terms of phosphate removal for HDF compared with HD at typical dialysis and hemodiafiltration treatment settings. These predictions are similar to the HDF advantage reported in the literature in studies where phosphate removal has been measured in spent dialysate.
Collapse
|
11
|
Peritoneal Dialysis Adequacy: Too Much of a Good Thing? KIDNEY360 2022; 3:1777-1779. [PMID: 36514734 PMCID: PMC9717664 DOI: 10.34067/kid.0000922022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Accepted: 08/08/2022] [Indexed: 05/23/2023]
|
12
|
Fluid Overload and Tissue Sodium Accumulation as Main Drivers of Protein Energy Malnutrition in Dialysis Patients. Nutrients 2022; 14:4489. [PMID: 36364751 PMCID: PMC9658859 DOI: 10.3390/nu14214489] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2022] [Revised: 10/17/2022] [Accepted: 10/19/2022] [Indexed: 01/15/2024] Open
Abstract
Protein energy malnutrition is recognized as a leading cause of morbidity and mortality in dialysis patients. Protein-energy-wasting process is observed in about 45% of the dialysis population using common biomarkers worldwide. Although several factors are implicated in protein energy wasting, inflammation and oxidative stress mechanisms play a central role in this pathogenic process. In this in-depth review, we analyzed the implication of sodium and water accumulation, as well as the role of fluid overload and fluid management, as major contributors to protein-energy-wasting process. Fluid overload and fluid depletion mimic a tide up and down phenomenon that contributes to inducing hypercatabolism and stimulates oxidation phosphorylation mechanisms at the cellular level in particular muscles. This endogenous metabolic water production may contribute to hyponatremia. In addition, salt tissue accumulation likely contributes to hypercatabolic state through locally inflammatory and immune-mediated mechanisms but also contributes to the perturbation of hormone receptors (i.e., insulin or growth hormone resistance). It is time to act more precisely on sodium and fluid imbalance to mitigate both nutritional and cardiovascular risks. Personalized management of sodium and fluid, using available tools including sodium management tool, has the potential to more adequately restore sodium and water homeostasis and to improve nutritional status and outcomes of dialysis patients.
Collapse
|
13
|
Circuit haemodynamics during non-citrate and regional citrate continuous renal replacement, and impact of blood flow on filter life. Int J Artif Organs 2022; 45:988-996. [PMID: 36036083 DOI: 10.1177/03913988221118585] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND During continuous renal replacement therapy (CRRT) with regional citrate anticoagulation (RCA), blood flow (Qb) might affect vascular access dysfunction (AD) and, thereby, circuit life. METHODS Circuit life and circuit haemodynamics were studied in three intensive care units (ICUs) by analysing hemofilter device data (Prismaflex®, Baxter, Chicago, IL). The three sites shared similar RCA protocols but differed in Qb (120-130 vs 150-200 mL/h). Non-RCA circuits were compared with RCA circuits in which the impact of Qb was also assessed. RESULTS About 3,981,906 min of circuit pressures were analysed in 2568 circuits in 567 patients. High-Qb RCA was associated with more extreme pressures, and greater AD (IRR 3.7 (1.93-7.08) as well as reduced filter life 21.1 (10.2-42.6) vs 27.0 (14.8-41.6) h). AD in high-Qb RCA circuits was associated with a 49% reduction in filter life, versus 24% reduction in low-Qb RCA, associated with a rise in the rate of increase in transfilter pressure. CONCLUSIONS High-Qb RCA-CRRT was associated with greater access dysfunction, earlier filter loss and increased haemodynamic impacts of access dysfunction, suggesting low-Qb RCA-CRRT may improve circuit mechanics, function and longevity.
Collapse
|
14
|
Current apparent treatment-resistant hypertension in patients undergoing peritoneal dialysis: A multi-center cross-sectional study. J Clin Hypertens (Greenwich) 2022; 24:493-501. [PMID: 35235248 PMCID: PMC8989747 DOI: 10.1111/jch.14455] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Revised: 01/25/2022] [Accepted: 02/12/2022] [Indexed: 01/09/2023]
Abstract
Apparent treatment‐resistant hypertension (aTRH) is the most commonly used term to report resistant hypertension (RH) and is considered as a common problem in dialysis population. However, few reports have focused on peritoneal dialysis (PD) hypertensive patients. The authors conducted a multi‐center cross‐sectional study involving 1789 PD patients from nine centers in Guangdong, China. The prevalence of aTRH was estimated by home blood pressure (BP) monitoring. Evaluating drug adherence through Eight‐item Morisky Medication Adherence Scale (MMAS‐8) and pill counting was performed to assess RH in one PD center. Related factors of aTRH were analyzed using logistic regression analysis. The prevalence of aTRH in PD patients was estimated at 42.2% (755 out of 1789 hypertensive patients) based on home BP. Of those, 91.4% patients were classified as uncontrolled RH, 2.0% as controlled RH, and 6.6% as refractory hypertension. The prevalence of RH was 40.6% and 41.9% among those with medium/high adherence based on the MMAS‐8 scores and the pill counting rate, respectively. PD patients who were younger, with higher body mass index, with lower serum albumin and poorer dialysis adequacy were significantly associated with higher aTRH incident. In conclusion, the present study demonstrates a high prevalence of aTRH in PD population, which occurs in about two in five treated hypertensive patients. Nutritional status and dialysis adequacy might tightly associate with aTRH.
Collapse
|
15
|
Changes in practice patterns in Japan from before to after JSDT 2013 guidelines on hemodialysis prescriptions: results from the JDOPPS. BMC Nephrol 2021; 22:339. [PMID: 34649519 PMCID: PMC8518149 DOI: 10.1186/s12882-021-02543-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Accepted: 09/27/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The Japanese Society for Dialysis Therapy (JSDT) published in 2013 inaugural hemodialysis (HD) guidelines. Specific targets include 1.4 for single-pool Kt/V (spKt/V) with a minimum dose of 1.2, minimum dialysis session length of 4 hours, minimum blood flow rate (BFR) of 200 mL/min, fluid removal rate no more than 15 mL/kg/hr, and hemodiafiltration (HDF) therapy for certain identified symptoms. We evaluated the effect of these guidelines on actual practice in the years spanning 2005 - 2018. METHODS Analyses were carried out to describe trends in the above HD prescription practices from December 2005 to April 2013 (before guideline publication) to August 2018 based on prevalent patient cross-sections from approximately 60 randomly selected HD facilities participating in the Japan Dialysis Outcomes and Practice Patterns Study. RESULTS From April 2006 to August 2017 continual rises occurred in mean spKt/V (from 1.35 to 1.49), and percent of patients having spKt/V>1.2 (71% to 85%). Mean BFR increased with time from 198.3 mL/min (April 2006) to 218.4 mL/min (August 2017) , along with percent of patients with BFR >200 ml/min (65% to 85%). HDF use increased slightly from 6% (April 2006 and August 2009) to 8% by April 2013, but increased greatly thereafter to 23% by August 2017. In contrast, mean HD treatment time showed little change from 2006-2017, whereas mean UFR declined from 11.3 in 2006 to 8.4 mL/Kg/hour in 2017. CONCLUSIONS From 2006 - 2018 Japanese HD patients experienced marked improvement in reaching the spKt/V target specified by the 2013 JSDT guidelines. This may have been due to moderate increase in mean BFR even though mean HD session length did not change much. In addition, HDF use increased dramatically in this time period. Other HD delivery changes during this time, such as increased use of super high flux dialyzers, also merit study. While we cannot definitively conclude a causal relationship between the publication of the guidelines and the subsequent practice changes in Japan, those changes moved practice closer to the recommendations of the guidelines.
Collapse
|
16
|
Toward an individualized determination of dialysis adequacy: a narrative review with special emphasis on incremental hemodialysis. Expert Rev Mol Diagn 2021; 21:1119-1137. [PMID: 34595991 DOI: 10.1080/14737159.2021.1987216] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
INTRODUCTION The search for the 'perfect' renal replacement therapy has been paralleled by the search for the perfect biomarkers for assessing dialysis adequacy. Three main families of markers have been assessed: small molecules (prototype: urea); middle molecules (prototype β2-microglobulin); comprehensive and nutritional markers (prototype of the simplified assessment, albumin levels; composite indexes as malnutrition-inflammation score). After an era of standardization of dialysis treatment, personalized dialysis schedules are increasingly proposed, challenging the dogma of thrice-weekly hemodialysis. AREAS COVERED In this review, we describe the advantages and limitations of the approaches mentioned above, focusing on the open questions regarding personalized schedules and incremental hemodialysis. EXPERT OPINION In the era of personalized dialysis, the assessment of dialysis adequacy should be likewise personalized, due to the limits of 'one size fits all' approaches. We have tried to summarize some of the relevant issues regarding the determination of dialysis adequacy, attempting to adapt them to an elderly, highly comorbidity population, which would probably benefit from tailor-made dialysis prescriptions. While no single biomarker allows precisely tailoring the dialysis dose, we suggest using a combination of clinical and biological markers to prescribe dialysis according to comorbidity, life expectancy, residual kidney function, and small and medium-size molecule depuration.
Collapse
|
17
|
Abstract
Background Twice-weekly hemodialysis (HD) could be regarded as an important part of incremental hemodialysis, volume status of this treatment model remains to be elucidated. Methods Patients undergoing regular twice-weekly or thrice-weekly hemodialysis in our unit on June 2015 were enrolled into the cohort study with an average of 2.02 years follow-up. Volume status of the subjects was evaluated by clinical characteristics, plasma B-type natriuretic peptide (BNP) levels and bioimpedance assessments with body composition monitor (BCM). Cox proportional hazards models and Kaplan–Meier analysis were used to compare patient survival between the two groups. Results Compared with patients on thrice-weekly HD, twice-weekly HD patients had significantly higher log-transformed BNP levels (2.54 ± 0.41 vs. 2.33 ± 0.49 pg/ml, p = 0.010). Overhydration (OH) and the ratio of overhydration to extracellular water (OH/ECW) in twice-weekly HD group were significantly higher than that of thrice-weekly HD (OH, 2.54 ± 1.42 vs. 1.88 ± 1.46, p = 0.033; OH/ECW, 0.17 ± 0.07 vs. 0.12 ± 0.08, p = 0.015). However, subgroup analysis of patients within 6 years HD vintage indicated that the two groups had similar hydration status. Multivariate Cox regression analysis showed that log-transformed BNP levels, serum albumin and diabetes status were predictors of mortality in hemodialysis patients. Kaplan–Meier survival analysis indicated that patients with BNP levels higher than 500 pg/ml had significantly worse survival compared with those with lower BNP levels (p = 0.014). Conclusions Twice-weekly hemodialysis patients had worse volume status than that of thrice-weekly HD patients especially for those with long-term dialysis vintage, BNP level was a powerful predictor of mortality in HD patients.
Collapse
|
18
|
Assessment of peritoneal thickness using CT in relation to dialysis adequacy in peritoneal dialysis patients. Ther Apher Dial 2021; 25:954-961. [PMID: 34370378 DOI: 10.1111/1744-9987.13719] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Revised: 07/27/2021] [Accepted: 08/06/2021] [Indexed: 11/27/2022]
Abstract
Studies assessing peritoneal thickness by CT in peritoneal dialysis (PD) patients are lacking. In this study, we aimed to investigate the association between peritoneal thickness as measured by CT and dialysis adequacy with peritoneal membrane characteristics in PD patients. Ninety-four PD patients were enrolled. Peritoneal thickness was measured by CT. Patients with and without a decrease in Kt/V of at least 0.3 over time were classified as Group 1 and Group 2, respectively. An increase of 0.1 unit of dialysate/plasma (D/P) creatinine over time were considered significant. The relationship between peritoneal membrane thickness, change in Kt/V, and peritoneal membrane characteristics were investigated. There were 31 (33.0%) patients in Group 1. The duration of PD (86.0 ± 64.1 vs. 59.6 ± 45.2 months, p: 0.023), peritoneal thickness (1.02 ± 0.37 vs. 0.87 ± 0.21 mm, p: 0.015), peritoneal calcification (7 [22.6%] vs. 3 [4.8%] patients, p: 0.013], increased D/P creatinine ratio (14 [45.2%] vs. 14 [22.2%] patients, p: 0.031) and CRP (13.9 ± 11.2 vs. 7.1 ± 4.8 mg/L, p: 0.045) were significantly higher in Group 1, whereas albumin (3.6 ± 0.5 vs. 3.8 ± 0.6 g/dL, p: 0.047) and parathyroid hormone (355.2 ± 260.2 vs. 532.1 ± 332.9 ng/L, p: 0.015) levels were significantly lower. Peritoneal thickness was significantly correlated with duration of PD (r: 0.775, p < 0.001) and CRP (r: 0.282, p: 0.006). Regression analysis showed that peritoneal thickness (Exp (B) [95% CI]: 0.029 [0.003-0.253], p: 0.001) was independent predictor of decreased Kt/V in PD patients. In conclusion, prolonged PD duration and increased peritoneal thickness are associated with a decrease in Kt/V over time. CT may be an alternative and noninvasive method instead of peritoneal biopsy for determining the structural changes of the peritoneal membrane .
Collapse
|
19
|
Global Dialysis Perspective: Kuwait. KIDNEY360 2021; 2:1015-1020. [PMID: 35373073 PMCID: PMC8791361 DOI: 10.34067/kid.0000392021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2021] [Accepted: 04/01/2021] [Indexed: 11/27/2022]
|
20
|
Improving dialysis adequacy and quality of life in patients undergoing hemodialysis with twice a week range of motion exercise. Ther Apher Dial 2021; 26:140-146. [PMID: 34129271 DOI: 10.1111/1744-9987.13701] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 06/03/2021] [Accepted: 06/12/2021] [Indexed: 12/01/2022]
Abstract
The study aimed to determine the effects of giving range of motion (ROM) twice a week as a form intradialytic exercise on patients' dialysis adequacy and quality of life. A total of 48 eligible participants were recruited and completed this study. The intervention group (n = 24) received twice a week ROM exercise over a 4 weeks period. The outcomes were assessed at pretest and at the end of the intervention. The study shows that ROM exercise was effective in improving dialyis adequacy that include ureum retention ratio (p= 0.027) and Kt/V (p= 0.017). Quality of life improved significantly particularly in the domains of symptom and effect of kidney disease. Integrating ROM into dialysis care shows as a potential intervention to improve dialysis adequacy and quality of life for patients undergoing hemodialysis. Future research should evaluate its efficacy using a randomized clinical trial design and larger sample of patients.
Collapse
|
21
|
Identifying key predictors of mortality in young patients on chronic haemodialysis-a machine learning approach. Nephrol Dial Transplant 2021; 36:519-528. [PMID: 32510143 DOI: 10.1093/ndt/gfaa128] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Accepted: 04/28/2020] [Indexed: 01/13/2023] Open
Abstract
BACKGROUND The mortality risk remains significant in paediatric and adult patients on chronic haemodialysis (HD) treatment. We aimed to identify factors associated with mortality in patients who started HD as children and continued HD as adults. METHODS The data originated from a cohort of patients <30 years of age who started HD in childhood (≤19 years) on thrice-weekly HD in outpatient DaVita dialysis centres between 2004 and 2016. Patients with at least 5 years of follow-up since the initiation of HD or death within 5 years were included; 105 variables relating to demographics, HD treatment and laboratory measurements were evaluated as predictors of 5-year mortality utilizing a machine learning approach (random forest). RESULTS A total of 363 patients were included in the analysis, with 84 patients having started HD at <12 years of age. Low albumin and elevated lactate dehydrogenase (LDH) were the two most important predictors of 5-year mortality. Other predictors included elevated red blood cell distribution width or blood pressure and decreased red blood cell count, haemoglobin, albumin:globulin ratio, ultrafiltration rate, z-score weight for age or single-pool Kt/V (below target). Mortality was predicted with an accuracy of 81%. CONCLUSIONS Mortality in paediatric and young adult patients on chronic HD is associated with multifactorial markers of nutrition, inflammation, anaemia and dialysis dose. This highlights the importance of multimodal intervention strategies besides adequate HD treatment as determined by Kt/V alone. The association with elevated LDH was not previously reported and may indicate the relevance of blood-membrane interactions, organ malperfusion or haematologic and metabolic changes during maintenance HD in this population.
Collapse
|
22
|
Dialyzer Performance During Hemodialysis Without Systemic Anticoagulation Using a Heparin-Grafted Dialyzer Combined With a Citrate-Enriched Dialysate: Results of the Randomized Crossover Noninferiority EvoCit Study. Am J Kidney Dis 2021; 79:79-87.e1. [PMID: 33940113 DOI: 10.1053/j.ajkd.2021.04.004] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2021] [Accepted: 04/06/2021] [Indexed: 11/11/2022]
Abstract
RATIONALE & OBJECTIVE The EvoCit study was designed to evaluate performance of a heparin-grafted dialyzer during hemodialysis with and without systemic anticoagulation. STUDY DESIGN Randomized, crossover, noninferiority trial. Noninferiority was defined as a difference of≤10% for the primary outcome. SETTING & PARTICIPANTS Single hemodialysis center; 26 prevalent patients treated with 617 hemodialysis sessions. INTERVENTIONS Hemodialysis using a heparin-grafted dialyzer combined with a 1.0mmol/L citrate-enriched dialysate ("EvoCit") without systemic anticoagulation compared with hemodialysis performed with a heparin-grafted dialyzer with systemic heparin ("EvoHep"). Patients were randomly allocated to a first period of 4 weeks and crossed over to the alternative strategy for a second period of 4 weeks. OUTCOMES The primary end point was the difference in Kt/Vurea between EvoCit and EvoHep. Secondary end points were urea reduction ratio, middle molecule removal, treatment time, thrombin generation, and reduction in dialyzer blood compartment volume. RESULTS The estimated difference in Kt/Vurea between EvoCit and EvoHep was-0.03 (95% CI, -0.06 to-0.007), establishing noninferiority with mean Kt/Vurea of 1.47±0.05 (SE) for EvoCit and 1.50±0.05 for EvoHep. Noninferiority was also established for reduction ratios of urea and β2-microglobulin. Premature discontinuation of dialysis was required for 4.2% of sessions among 6 patients during EvoCit and no sessions during EvoHep. Effective treatment time was 236±5 minutes for EvoCit and 238±1 minutes for EvoHep. Thrombin generation was increased and there was greater reduction in dialyzer blood compartment volume after treatments with EvoCit compared with EvoHep. LIMITATIONS The effects of avoiding systemic anticoagulation on clinical outcomes were not evaluated. CONCLUSIONS EvoCit is noninferior to EvoHep with respect to solute clearance but results in a greater number of shortened treatments, more membrane clotting, and greater thrombin generation TRIAL REGISTRATION: Registered at ClinicalTrials.gov with study number NCT03887468.
Collapse
|
23
|
Optical Method and Biochemical Source for the Assessment of the Middle-Molecule Uremic Toxin β2-Microglobulin in Spent Dialysate. Toxins (Basel) 2021; 13:toxins13040255. [PMID: 33807387 PMCID: PMC8067283 DOI: 10.3390/toxins13040255] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2021] [Revised: 03/23/2021] [Accepted: 03/29/2021] [Indexed: 02/07/2023] Open
Abstract
Optical monitoring of spent dialysate has been used to estimate the removal of water-soluble low molecular weight as well as protein-bound uremic toxins from the blood of end stage kidney disease (ESKD) patients. The aim of this work was to develop an optical method to estimate the removal of β2-microglobulin (β2M), a marker of middle molecule (MM) uremic toxins, during hemodialysis (HD) treatment. Ultraviolet (UV) and fluorescence spectra of dialysate samples were recorded from 88 dialysis sessions of 22 ESKD patients, receiving four different settings of dialysis treatments. Stepwise regression was used to obtain the best model for the assessment of β2M concentration in the spent dialysate. The correlation coefficient 0.958 and an accuracy of 0.000 ± 0.304 mg/L was achieved between laboratory and optically estimated β2M concentrations in spent dialysate for the entire cohort. Optically and laboratory estimated reduction ratio (RR) and total removed solute (TRS) of β2M were not statistically different (p > 0.35). Dialytic elimination of MM uremic toxin β2M can be followed optically during dialysis treatment of ESKD patients. The main contributors to the optical signal of the MM fraction in the spent dialysate were provisionally identified as tryptophan (Trp) in small peptides and proteins, and advanced glycation end-products.
Collapse
|
24
|
Kt/V: achievement, predictors and relationship to mortality in hemodialysis patients in the Gulf Cooperation Council countries: results from DOPPS (2012-18). Clin Kidney J 2021; 14:820-830. [PMID: 33777365 PMCID: PMC7986324 DOI: 10.1093/ckj/sfz195] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2019] [Accepted: 12/16/2019] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND Dialysis adequacy, as measured by single pool Kt/V, is an important parameter for assessing hemodialysis (HD) patients' health. Guidelines have recommended Kt/V of 1.2 as the minimum dose for thrice-weekly HD. We describe Kt/V achievement, its predictors and its relationship with mortality in the Gulf Cooperation Council (GCC) (Bahrain, Kuwait, Oman, Qatar, Saudi Arabia and the United Arab Emirates). METHODS We analyzed data (2012-18) from the prospective cohort Dialysis Outcomes and Practice Patterns Study for 1544 GCC patients ≥18 years old and on dialysis >180 days. RESULTS Thirty-four percent of GCC HD patients had low Kt/V (<1.2) versus 5%-17% in Canada, Europe, Japan and the USA. Across the GCC countries, low Kt/V prevalence ranged from 10% to 54%. In multivariable logistic regression, low Kt/V was more common (P < 0.05) with larger body weight and height, being male, shorter treatment time (TT), lower blood flow rate (BFR), greater comorbidity burden and using HD versus hemodiafiltration. In adjusted Cox models, low Kt/V was strongly related to higher mortality in women [hazard ratio (HR) = 1.91, 95% confidence interval (CI) 1.09-3.34] but not in men (HR = 1.16, 95% CI 0.70-1.92). Low BFR (<350 mL/min) and TT (<4 h) were common; 41% of low Kt/V cases were attributable to low BFR or TT (52% for women and 36% for men). CONCLUSION Relatively large proportions of GCC HD patients have low Kt/V. Increasing BFR to ≥350 mL/min and TT to ≥4 h thrice weekly will reduce low Kt/V prevalence and may improve survival in GCC HD patients-particularly among women.
Collapse
|
25
|
Relationship between arteriovenous fistula cannulation practices and dialysis adequacy: A prospective, multicenter study. J Ren Care 2021; 48:41-48. [PMID: 33492745 DOI: 10.1111/jorc.12365] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2020] [Revised: 12/21/2020] [Accepted: 12/29/2020] [Indexed: 11/28/2022]
Abstract
BACKGROUND Successful arteriovenous fistula cannulation ensures maximum patient benefit in the haemodialysis procedure. OBJECTIVE The aim of this study was to determine the effect of various cannulation methods used for arteriovenous fistulas on dialysis adequacy. DESIGN It is a descriptive, cross-sectional and multicenter study. PARTICIPANTS A total of 164 dialysis patients from four dialysis centers were included. MEASUREMENTS Data were collected by determining patients' characteristics and the arteriovenous fistula cannulation method used, in addition to recording the Kt/V and urea reduction ratio values to evaluate dialysis adequacy. The mean Kt/V and urea reduction ratio values over 3 months after dialysis initiation were used. This trial is registered with ClinicalTrials.gov, NCT04270292. RESULTS Cannulation with the puncture method was used in 53% of the patients; the fistula needles were inserted in the antegrade direction in 43.9% of the patients; the arterial needle was rotated after fistula needle placement in 63.4% of the patients; and the arterial and venous needles were on the same vascular line in 15.2% of the patients. Placement of the fistula needle in the antegrade direction increased the Kt/V value 0.164 times (95% confidence interval: 0.002-0.212, p = .047). CONCLUSION Antegrade placement could be a factor influencing dialysis adequacy. We suggest antegrade interventions to the fistula to maximize the patient benefit from the haemodialysis treatment.
Collapse
|
26
|
Development and validation of a novel score to predict dialysis inadequacy in continuous ambulatory peritoneal dialysis patients. J Int Med Res 2021; 49:300060520984591. [PMID: 33472494 PMCID: PMC7829543 DOI: 10.1177/0300060520984591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
Objective Adequate dialysis is of great importance for continuous ambulatory peritoneal
dialysis (CAPD) patients. This study aimed to develop and validate an easily
applicable quantitative dialysis adequacy risk scoring system in CAPD
patients based on laboratory parameters from a single blood draw. Methods A total of 634 CAPD patients from four study centers were enrolled in this
study (345 and 289 patients in development and validation groups,
respectively). A risk score model for inadequate dialysis was developed
based on multivariate regression analysis, which was validated by the area
under the receiver operator curve and calibrated by a calibration curve. Results Seven independent predictors for inadequate dialysis were identified in the
development group (male sex, hypoalbuminemia, anemia, being overweight,
hyperuricemia, estimated glomerular filtration rate <4.7 mL/min/1.73
m2, and serum creatinine >800 μmol/L). A risk prediction
score model was established and validated in the development and validation
groups. Further analysis indicated that this model is suitable for CAPD
patients with a wide range of clinical manifestations. Conclusion An easily applicable novel risk scoring system was established to detect
inadequate dialysis in CAPD patients.
Collapse
|
27
|
Normalized Protein Catabolic Rate Is a Superior Nutritional Marker Associated With Dialysis Adequacy in Continuous Ambulatory Peritoneal Dialysis Patients. Front Med (Lausanne) 2021; 7:603725. [PMID: 33511142 PMCID: PMC7835658 DOI: 10.3389/fmed.2020.603725] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2020] [Accepted: 12/09/2020] [Indexed: 02/05/2023] Open
Abstract
Introduction: Current knowledge of the relationship between normalized protein catabolic rate (nPCR) and dialysis adequacy is limited. Our study aimed to explore the potential relationship between nPCR and dialysis adequacy. Methods: In this cross-sectional study, we analyzed the association of nPCR with peritoneal dialysis adequacy in 266 continuous ambulatory peritoneal dialysis (CAPD) patients (mean age 48.6 ± 13.1 years; 50.8% male). The patients were divided into two groups: a dialysis inadequacy group (total weekly Kt/V urea < 1.70) and a dialysis adequacy group (total weekly Kt/V urea≥1.70). We then analyzed the correlation between dialysis adequacy and the patients' primary cause of end-stage renal disease, nutritional and inflammatory markers, and biochemical parameters. Multivariable logistic regression analysis was also used to identify risk factors for inadequate dialysis. Results: We observed a significantly higher level of nPCR (0.98 ± 0.22 vs. 0.79 ± 0.18 g/kg/day, p < 0.001) in the dialysis adequacy group, whereas we observed no significant differences among other nutritional markers such as albumin, prealbumin, and transferrin. Correlation analyses revealed that dialysis adequacy was positively associated with residual glomerular filtration rate (rGFR), hemoglobin, serum calcium, and body mass index (BMI), while dialysis adequacy was negatively associated with leak-protein, uric acid, high-sensitivity C-reactive protein, interleukin-6, and serum phosphorus. Furthermore, a logistic regression analysis revealed that gender (male), nPCR <0.815 g/kg/day, higher weight, and rGFR <2.43 mL/min/1.73 m2 were independent risk factors for inadequate dialysis. Conclusion: Nutritional status is closely associated with dialysis adequacy. Among common nutritional markers, nPCR may be superior for predicting CAPD dialysis adequacy. Gender (male), nPCR <0.815 g/kg/day, higher weight, and rGFR <2.43 mL/min/1.73 m2 are independent risk factors for dialysis inadequacy in CAPD patients.
Collapse
|
28
|
Renal replacement therapy in patients on extracorporeal membrane oxygenation support: Who and how. Int J Artif Organs 2020; 44:531-538. [PMID: 33300402 DOI: 10.1177/0391398820980451] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Patients undergoing extracorporeal membrane oxygenation (ECMO) support frequently develop renal failure requiring renal replacement therapy (RRT). RRT may be performed via a dialysis catheter based approach or via the ECMO circuit. We describe our experience with both techniques. A total of 68 patients undergoing ECMO support at our institution were retrospectively analyzed. Predictors of renal failure requiring RRT were determined. Patients undergoing RRT via a dialysis catheter were compared with those undergoing RRT via the ECMO circuit. 10 of the 68 patients required RRT support prior to ECMO. Of the remaining 58 patients, 25 (43%) required new RRT support on ECMO. Lower albumin levels and postcardiotomy shock were predictive of new renal failure requiring RRT on ECMO. RRT performed via the ECMO circuit demonstrated similar efficacy as via a dialysis catheter. Outcomes were much worse for patients requiring new RRT on ECMO support, with a doubling of the length of ECMO support and less that one-third the survival rate of patients not requiring RRT on ECMO support. New renal failure requiring RRT occurs in nearly one-half of patients on ECMO support, with poor outcomes. RRT may be performed via the ECMO circuit with similar efficacy as via a dialysis catheter.
Collapse
|
29
|
Achieving high convective volume in hemodiafiltration: Lessons learned after successful implementation in the HDFit trial. Hemodial Int 2020; 25:50-59. [PMID: 33058473 DOI: 10.1111/hdi.12891] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Revised: 08/19/2020] [Accepted: 09/17/2020] [Indexed: 12/13/2022]
Abstract
BACKGROUND AND OBJECTIVES High-volume online hemodiafiltration (OL-HDF) associates with improved outcomes compared to hemodialysis (HD), provided adequate dosing is achieved as estimated from convective volume (CV). Achievement of high CV and its impact on biochemical indicators following a standardized protocol converting HD patients to OL-HDF has not been systematically reported. We assessed the success of implementation of OL-HDF in clinics naïve to the modality. DESIGN, SETTING, PARTICIPANTS, AND MEASUREMENTS We analyzed the results of the implementation of postdilution OL-HDF in patients randomized to the HDF arm of a clinical trial (impact of hemoDiaFIlTration on physical activity and self-reported outcomes: a randomized controlled trial (HDFit) trial [ClinicalTrials.gov:NCT02787161]). The day before randomization of the first patient to OL-HDF at each clinic staff started a 3-day in-person training module on operation of Fresenius 5008 CorDiax machine in HDF mode. Patients were converted from high-flux HD to OL-HDF under oversight of trainers. OL-HDF was performed over a 6-months follow-up with a CV target of 22 L/treatment. We characterized median achieved CV >22 L/treatment record and analyzed the impact of HDF on biochemical variables. RESULTS Ninety-seven patients (mean age 53 ± 16 years, 29% with diabetes, and 11% had a catheter) from 13 clinics randomized to the OL-HDF arm of the trial were converted from HD to HDF. Median CV > 22 L/treatment was achieved in 99% (94/95) of OL-HDF patients throughout follow-up. Monthly mean CV ranged from 27.1 L to 27.5 L. OL-HDF provided an increased single pool Kt/V at 3-months (0.2 [95% CI: 0.1-0.3]) and 6-months (0.2 [95% CI: 0.1-0.4]) compared to baseline, and reduced phosphate at 3-months (-0.4 mg/dL [95% CI: -0.8 to -0.12]) of follow-up. CONCLUSIONS High-volume online hemodiafiltration was successfully implemented with 99% of patients achieving protocol defined CV target. Monthly mean CV was consistently >22 L/treatment during follow-up. Kt/V increased, and phosphate decreased with OL-HDF. Findings resulting from a short training period in several dialysis facilities appear to suggest HDF is an easily implementable technique.
Collapse
|
30
|
Intermittent hemodiafiltration as a down-step transition therapy in patients with acute kidney injury admitted to intensive care unit who initially underwent continuous venovenous hemodiafiltration. Int J Artif Organs 2020; 44:223-228. [PMID: 32907438 DOI: 10.1177/0391398820952801] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND/AIMS Continuous renal replacement therapies (CRRT) are initially employed in patients with acute kidney injury (AKI) in ICU setting. After the period of serious illness, hemodialysis is usually used as a mode of transition from CRRT. Intermittent hemodiafiltration (HDF) is not commonly applied in this scenario. OBJECTIVES To evaluate the feasibility of using HDF as transition therapy after CVVHDF in critically patients with AKI. METHODS An observational and prospective pilot study was conducted in ICU patients with dialysis-requiring AKI. Patients were initially treated with CVVHDF and, after medical improvement, those who still needed renal replacement therapy were switched to HDF treatment. RESULTS Ten Patients underwent 53 HDF sessions (mean of 5.3 sessions/patient). The main cause of renal dysfunction was sepsis (N = 7; 70%). The APACHE II mean score was 27.6 ± 6.9. During HDF treatment, the urea reduction ratio was 64.5 ± 7.5%, for β-2 microglobulin serum levels the percentage of decrease was 42.0 ± 7.8%, and for Cystatin C was 36.2 ± 6.9%. Five episodes of arterial hypotension occurred (9.4% of sessions). There were 20 episodes of electrolytic disturbance (37.7% of sessions), mainly hypophosphatemia. No pyrogenic or suggestive episode of bacteremia was observed. CONCLUSION Hemodiafiltration was safe and efficient to treat critically ill patients with acute kidney injury during the transition phase from continuous to intermittent dialysis modality. Special attention should be paid regarding the occurrence of electrolytic disturbance, mainly hypophosphatemia.
Collapse
|
31
|
Eating during the Hemodialysis Session: A Practice Improving Nutritional Status or a Risk Factor for Intradialytic Hypotension and Reduced Dialysis Adequacy? Nutrients 2020; 12:nu12061703. [PMID: 32517256 PMCID: PMC7352512 DOI: 10.3390/nu12061703] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 05/29/2020] [Accepted: 06/04/2020] [Indexed: 02/07/2023] Open
Abstract
Historically, eating during the hemodialysis treatment has been associated with increased risk for adverse intradialytic symptoms and events, risks that have resulted in the implementation of restrictive in-center nutrition policies. Recent studies, however, have recorded a shift in clinical practice with a higher proportion of physicians following the view that administration of intradialytic meals and supplements represents a simple and effective approach to enhance caloric intake and improve nutritional status among patients on hemodialysis. This shift towards less restrictive in-center nutrition practices is mainly supported by evidence from observational studies associating intradialytic nutritional supplementation with improvements in protein-energy wasting, inflammatory state, and health-related quality of life. In sharp contrast, earlier and recent interventional studies have documented that feeding during the hemodialysis treatment provokes a rapid postprandial decline in blood pressure and raises the incidence of symptomatic intradialytic hypotension. Furthermore, other studies have shown that postprandial redistribution in intravascular volume and enhanced blood supply to the gastrointestinal circulation may interfere with the adequacy of the delivered hemodialysis. Those who defend the position that intradialytic nutritional support is beneficial do not dispute the physiology of postprandial hemodynamic response, but they argue against its clinical significance. In this article, we provide an overview of studies that explored the effect of eating during the hemodialysis treatment on intradialytic hemodynamic stability and adequacy of the delivered hemodialysis. We reason that these risks have important clinical implications that are not counteracted by anticipated benefits of this strategy on caloric intake and nutritional status.
Collapse
|
32
|
Unilateral nephrectomy versus renal arterial embolization and technique survival in peritoneal dialysis patients with autosomal dominant polycystic kidney disease. Nephrol Dial Transplant 2020; 35:320-327. [PMID: 31747008 DOI: 10.1093/ndt/gfz200] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2019] [Accepted: 08/21/2019] [Indexed: 01/13/2023] Open
Abstract
BACKGROUND Autosomal dominant polycystic kidney disease (ADPKD) is a common genetic disorder associated with progressive enlargement of the kidneys and liver. ADPKD patients may require renal volume reduction, especially before renal transplantation. The standard treatment is unilateral nephrectomy. However, surgery incurs a risk of blood transfusion and alloimmunization. Furthermore, when patients are treated with peritoneal dialysis (PD), surgery is associated with an increased risk of temporary or definitive switch to haemodialysis (HD). Unilateral renal arterial embolization can be used as an alternative approach to nephrectomy. METHODS We performed a multicentre retrospective study to compare the technique of survival of PD after transcatheter renal artery embolization with that of nephrectomy in an ADPKD population. We included ADPKD patients treated with PD submitted to renal volume reduction by either surgery or arterial embolization. Secondary objectives were to compare the frequency and duration of a temporary switch to HD in both groups and the impact of the procedure on PD adequacy parameters. RESULTS More than 700 patient files from 12 centres were screened. Only 37 patients met the inclusion criteria (i.e. treated with PD at the time of renal volume reduction) and were included in the study (21 embolized and 16 nephrectomized). Permanent switch to HD was observed in 6 embolized patients (28.6%) versus 11 nephrectomized patients (68.8%) (P = 0.0001). Renal artery embolization was associated with better technique survival: subdistribution hazard ratio (SHR) 0.29 [95% confidence interval (CI) 0.12-0.75; P = 0.01]. By multivariate analysis, renal volume reduction by embolization and male gender were associated with a decreased risk of switching to HD. After embolization, a decrease in PD adequacy parameters was observed but no embolized patients required temporary HD; the duration of hospitalization was significantly lower [5 days [interquartile range (IQR) 4.0-6.0] in the embolization group versus 8.5 days (IQR 6.0-11.0) in the surgery group. CONCLUSIONS Transcatheter renal artery embolization yields better technique survival of PD in ADPKD patients requiring renal volume reduction.
Collapse
|
33
|
Does subjective assessment of dialyzer appearance reflect dialyzer performance in online hemodiafiltration? Hemodial Int 2019; 24:61-70. [PMID: 31633275 PMCID: PMC7027516 DOI: 10.1111/hdi.12788] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Revised: 08/28/2019] [Accepted: 08/30/2019] [Indexed: 11/29/2022]
Abstract
Introduction: In post‐dilution online hemodiafiltration, a very thin balance subsists in preventing coagulation of the extracorporeal circuit (ECC) during treatment and bleeding in the patient, concerning dialyzer status and anticoagulation dose. The aim of this study was to assess whether there are clinical outcome differences between the visual aspect of the dialyzer's status in terms of clotted fibers at end of dialysis treatments, single‐pool urea kinetic modeling (spKt/V) and substitution volume (SubsVol). Methods: It is a multicenter, descriptive‐correlational study, involving 2829 patients during April 2016. Previous training was given to the Nursing staff to evaluate and classify both the dialyzer's and the venous chamber's appearance of the ECC venous line. Registration was performed at bedside immediately after the patient disconnection. Findings and discussion: Mean age was 68.96 years (SD = 13.75), 60.8% were men. The average hematocrit was 33.91% (SD = 3.45%). The average dry weight was 68.53 kg (SD = 13.27 kg). Mean unfractioned heparin (UFH) dose was 58.13 IU/kg. Only 32.4% of the patients had a clean dialyzer at the end of treatment. 19.4% of patients finished the treatment with more than 10% of clotted fibers. Patients with no residual blood (clean, 32.4%) presented a higher UFH dose (66.32 IU/kg) compared to overall average dose. UFH dose had a significant effect on dialyzer status. There were significant differences in average of spKt/V and SubsVol between the category clean and the other categories of dialyzer's status. Evaluating the dialyzer status represents an excellent opportunity to help the physicians to establish an ideal heparin dose. Only the category clean is significant to achieve the target. The nursing staff, by classifying the ECC appearance at patient's bedside and recording it in a centralized database, can be a major contributor to achieve an individualized and optimal UFH dose and subsequently better patient outcomes.
Collapse
|
34
|
Influence of gender and age on haemodialysis practices: a European multicentre analysis. Clin Kidney J 2019; 13:217-224. [PMID: 32296527 PMCID: PMC7147302 DOI: 10.1093/ckj/sfz069] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Accepted: 04/30/2019] [Indexed: 11/25/2022] Open
Abstract
Background Women of all ages and elderly patients of both genders comprise an increasing proportion of the haemodialysis population. Worldwide, significant differences in practice patterns and treatment results exist between genders and among younger versus older patients. Although efforts to mitigate sex-based differences have been attempted, significant disparities still exist. Methods This retrospective cohort study included all 1247 prevalent haemodialysis patients in DaVita units in Portugal (five dialysis centres, n = 730) and Poland (seven centres, n = 517). Demographic data, dialysis practice patterns, vascular access prevalence and the achievement of a variety of Kidney Disease: Improving Global Outcomes (KDIGO) treatment targets were evaluated in relation to gender and age groups. Results Body weight and the prescribed dialysis blood flow rate were lower in women (P < 0.001), whereas treated blood volume per kilogram per session was higher (P < 0.01), resulting in higher single-pool Kt/V in women than in men (P < 0.001). Haemoglobin was significantly higher in men (P = 0.01), but the proportion of patients within target range (10–12 g/dL) was similar. Men more often had an arteriovenous fistula than women (80% versus 73%; P < 0.01) with a similar percentage of central venous catheters. There were no gender-specific differences in terms of dialysis adequacy, anaemia parameters or mineral and bone disorder parameters, or in the attainment of KDIGO targets between women and men >80 years of age. Conclusions This large, multicentre real-world analysis indicates that haemodialysis practices and treatment targets are similar for women and men, including the most elderly, in DaVita haemodialysis clinics in Europe.
Collapse
|
35
|
Impact of Percent Body Fat on All-Cause Mortality among Adequate Dialysis Patients with and without Insulin Resistance: A Multi-Center Prospective Cohort Study. Nutrients 2019; 11:nu11061304. [PMID: 31181824 PMCID: PMC6627844 DOI: 10.3390/nu11061304] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Revised: 06/04/2019] [Accepted: 06/04/2019] [Indexed: 12/24/2022] Open
Abstract
The association between body fat and mortality in hemodialysis patients remains controversial. We examined the effect of percent body fat (PBF) on all-cause mortality among adequate hemodialysis patients with and without insulin resistance (IR). A prospective cohort study was conducted on 365 adequate hemodialysis patients (equilibrated Kt/V ≥ 1.2) from seven hospitals. Patients’ characteristics and clinical and biochemical parameters were assessed at baseline between September 2013 and April 2017. Patients were followed up for all-cause mortality until April 2018. The median value of homeostatic model assessment (HOMA-IR) was used to classify IR. Cox proportional hazard models were utilized to examine predictors of all-cause mortality. During 1.4 (1.0–3.2) years of follow-up, 46 patients died. In patients with IR (HOMA-IR ≥ 5.18), PBF was significantly higher in the survival group than in the death group (31.3 ± 9.0 vs. 25.4 ± 8.2, p = 0.005). After controlling for confounding factors, PBF was significantly associated with lower risk for all-cause mortality in patients with IR (hazard ratio, 0.94; 95% confidence interval, 0.89–1.00; p = 0.033). The association was not observed in patients without IR. In conclusion, percent body fat shows a protective effect on survival in hemodialysis patients with IR.
Collapse
|
36
|
Mid-arm circumference, body fat, nutritional and inflammatory biomarkers, blood glucose, dialysis adequacy influence all-cause mortality in hemodialysis patients: A prospective cohort study. Medicine (Baltimore) 2019; 98:e14930. [PMID: 30896655 PMCID: PMC6708842 DOI: 10.1097/md.0000000000014930] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
Hemodialysis patients are at the high risk for morbidity and mortality. Evaluation and management of body composition and biochemical values are important to improve dialysis outcomes. We aimed to examine the effects of the mid-arm circumference, body fat, nutritional and inflammatory biomarkers, blood glucose, and dialysis adequacy on the mortality.A prospective cohort study was conducted on 375 patients from 7 hospital-based dialysis centers. At baseline between September 2013 and April 2017, we assessed patients' characteristics using chart review, body composition using the bioelectrical impedance analysis, and biochemical parameters using available laboratory tests. Patients were followed-up for all-cause mortality until April 2018. Kaplan-Meier Curves with Log-rank test, and Cox proportional hazards models were used to analyze the effects of assessed factors on the mortality.During the median of follow-up time of 1.4 (1.0-3.2) years, 47 (12.5%) patients died. In the multivariate analysis, mid-arm circumference (hazard ratio, HR, 0.90; 95% confidence interval, 95%CI, 0.82-0.99; P = .036), body fat mass (HR, 0.95; 95%CI, 0.91-1.00; P = .031), percent body fat (HR, 0.96; 95%CI, 0.92-0.99; P = .024), serum creatinine (HR, 0.81; 95%CI, 0.68-0.96; P = .015), and eKt/V (HR, 0.07; 95%CI, 0.01-0.33; P = .001) reduced the mortality risk. Inflammation (HR, 2.90; 95%CI, 1.59-5.27; P < .001), hyperglycemia (HR, 2.16; 95%CI, 1.06-4.40; P = .033), and low serum uric acid (HR, 2.22; 95%CI, 1.15-4.31; P = .018) increased the death risk.In hemodialysis patients, the higher values of the mid-arm circumference, body fat, serum creatinine, uric acid, and dialysis adequacy were associated with lower mortality, whereas, inflammation and hyperglycemia associated with higher mortality.
Collapse
|
37
|
Differences in Dialysis Efficacy Have Limited Effects on Protein-Bound Uremic Toxins Plasma Levels over Time. Toxins (Basel) 2019; 11:toxins11010047. [PMID: 30654454 PMCID: PMC6356521 DOI: 10.3390/toxins11010047] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2018] [Revised: 01/11/2019] [Accepted: 01/13/2019] [Indexed: 12/17/2022] Open
Abstract
The protein-bound uremic toxins para-cresyl sulfate (pCS) and indoxyl sulfate (IS) are associated with cardiovascular disease in chronic renal failure, but the effect of different dialysis procedures on their plasma levels over time is poorly studied. The present prospective, randomized, cross-over trial tested dialysis efficacy and monitored pre-treatment pCS and IS concentrations in 15 patients on low-flux and high-flux hemodialysis and high-convective volume postdilution hemodiafiltration over six weeks each. Although hemodiafiltration achieved by far the highest toxin removal, only the mean total IS level was decreased at week three (16.6 ± 12.1 mg/L) compared to baseline (18.9 ± 13.0 mg/L, p = 0.027) and to low-flux dialysis (20.0 ± 12.7 mg/L, p = 0.021). At week six, the total IS concentration in hemodiafiltration reached the initial values again. Concentrations of free IS and free and total pCS remained unaltered. Highest beta2-microglobulin elimination in hemodiafiltration (p < 0.001) led to a persistent decrease of the plasma levels at week three and six (each p < 0.001). In contrast, absent removal in low-flux dialysis resulted in rising beta2-microglobulin concentrations (p < 0.001). In conclusion, this trial demonstrated that even large differences in instantaneous protein-bound toxin removal by current extracorporeal dialysis techniques may have only limited impact on IS and pCS plasma levels in the longer term.
Collapse
|
38
|
A two-pool kinetic model predicts phosphate concentrations during and shortly following a conventional (three times weekly) hemodialysis session. Nephrol Dial Transplant 2018; 33:76-84. [PMID: 27738228 DOI: 10.1093/ndt/gfw347] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2016] [Accepted: 08/20/2016] [Indexed: 01/17/2023] Open
Abstract
Background Previous studies have suggested that a conventional two-pool model cannot be used to predict intradialysis and early postdialysis phosphorus concentrations. Methods A conventional two-pool urea model was modified by increasing the distal compartment volume from two-thirds to three times the total body water and by the use of a dynamically variable intercompartmental phosphorus clearance during dialysis. The phosphate solver model parameters were derived from an examination of the results in the literature, and fine-tuned using a training set (F4) of 415 Hemodialysis (HEMO) Study patients studied during a dialysis session where phosphorus was measured at 4 months of follow-up. Validation was done in a group of 380 different HEMO Study patients plus 9 from the original F4 group, who were evaluated at 36 months of follow-up. Results The model predicted measured median early (1 h) intradialysis, end-dialysis and 30-min postdialysis serum phosphorus levels in the test and validation datasets with little apparent bias, including the highest and lowest deciles of predialysis serum phosphorus. The model tended to underestimate slightly intradialysis serum phosphorus when predialysis serum phosphorus was <3.0 mg/dL (0.97 mmol/L). There was a large scatter and standard deviation among patients, and whether aberrant values represent a patient-specific phenomenon is unclear. Conclusions A modified two-pool model using a slightly expanded distal compartment and a dynamically varying intercompartmental clearance, depending on the intradialysis phosphorus concentration, can be used to predict serum phosphorus level during and shortly after dialysis, in patients following a conventional three times per week dialysis prescription.
Collapse
|
39
|
Evaluation of the efficacy of a medium cut-off dialyser and comparison with other high-flux dialysers in conventional haemodialysis and online haemodiafiltration. Clin Kidney J 2018; 11:742-746. [PMID: 30288272 PMCID: PMC6165747 DOI: 10.1093/ckj/sfy004] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2017] [Accepted: 12/19/2017] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND Online haemodiafiltration (OL-HDF) has been shown to reduce all-cause mortality versus conventional haemodialysis (HD); however, it is not always available. In these situations, a novel class of membranes with a higher pore size, medium cut-off (MCO) dialysers, could be promising. The aim of this study is to evaluate the efficacy of an MCO dialyser in the removal of small and medium-size molecules and compare it with standard high-flux (HF) dialysers in HD and OL-HDF. METHODS In this crossover study, 18 prevalent HD patients were studied in three single mid-week dialysis treatments during three consecutive weeks as follows: first week with OL-HDF with a standard HF dialyser, second week with conventional HD with a standard HF dialyser and third week with conventional HD with an MCO dialyser. Reduction ratios (RRs) of different-sized molecules and albumin losses were collected for the different dialysers. RESULTS MCO HD provided a greater reduction of middle and larger middle molecules compared with standard HF HD [rate reduction (RR) β2-microglobulin 74.7% versus 69.7%, P=0.01; RR myoglobin 62.5% versus 34.3%, P=0.001; RR prolactin 60% versus 32.8%, P=0.001; RR α1-glycoprotein 2.8% versus -0.1%, P=0.01]. We found no difference in the clearance of small and larger middle molecules comparing MCO HD with OL-HDF. Albumin losses were 0.03 g/session with MCO HD and 3.1 g/session with OL-HDF (P=0.001). CONCLUSION MCO HD is superior to standard HF HD in the removal of middle and larger middle molecules and it is not inferior to OL-HDF in the clearance of small and larger middle molecules. Thus it could be an alternative in patients in which it is not possible to perform OL-HDF.
Collapse
|
40
|
Effects of Citrate Acid Concentrate on Hemo dialysis Adequacy, Reuse, and Quality of Life: A Prospective Randomized Crossover Trial. Indian J Nephrol 2018; 28:287-290. [PMID: 30158747 PMCID: PMC6094840 DOI: 10.4103/ijn.ijn_154_17] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
We conducted a randomized crossover trial to identify whether the use of citrate dialysate (CD) for bicarbonate hemodialysis is beneficial compared to regular acetate dialysate (AD) in terms of adequacy, reuse, and quality of life. Thirty-two stable end-stage renal disease patients on twice-weekly maintenance hemodialysis were randomly assigned to CD or AD fluid in a single-blinded randomized prospective crossover trial of 1-year duration. The primary outcomes studied were the impact of CD in comparison with AD on hemodialysis adequacy, reuse of dialyzer, and quality of life. Secondary outcomes studied were the effect on intradialytic hypotension, acidosis correction, and episodes of symptomatic hypocalcemia. A total number of 28 patients underwent a total of 1456 sessions of hemodialysis with CD over 6 months and 1456 sessions with AD over 6 months. There was a significant increase in dialyzer reuse with the use of CD (P = 0.02). There was no difference in dialyzer adequacy as measured by Single pool Kt/V (spKt/V) (P = 0.840) and urea reduction ratio (%) (P = 0.90). Quality of life did not differ between the two groups. No statistically significant difference was observed in predialysis arterial pH (P = 0.23) serum bicarbonate (0.17) and calcium change (P = 0.16). CD is safe and equally effective as compared to AD. It significantly improves the reuse of dialyzer but it does not offer any added advantage in terms of improvement in hemodialysis adequacy and quality of care.
Collapse
|
41
|
Principles of Renal Function Measurement (Limitations of Gotch's Kt/V). Can J Kidney Health Dis 2018; 5:2054358118776020. [PMID: 29899999 PMCID: PMC5985543 DOI: 10.1177/2054358118776020] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2017] [Accepted: 02/24/2018] [Indexed: 11/16/2022] Open
Abstract
Kt/V is a nondimensional number and a scaling parameter that has, with arbitrary definitions, been recast as a measure of dialysis by Gotch and Lysaght. This editorial discusses the concept of nondimensional numbers within the context of dialysis measurement, modeling, and medical evidence. It concludes that Gotch's Kt/V, Lysaght's Kt/V, and standardized Kt/V are not well suited to measure dialysis. An ideal dialysis measure would be proportional to toxins cleared by the kidney, portable with regard to dialysis modality, practical (largely devoid of calculations) and reflective of the pathology/physiology.
Collapse
|
42
|
Creatinine generation from kinetic modeling with or without postdialysis serum creatinine measurement: results from the HEMO study. Nephrol Dial Transplant 2018; 32:1926-1933. [PMID: 28379486 DOI: 10.1093/ndt/gfx038] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2016] [Accepted: 02/08/2017] [Indexed: 11/14/2022] Open
Abstract
Background A convenient method to estimate the creatinine generation rate and measures of creatinine clearance in hemodialysis patients using formal kinetic modeling and standard pre- and postdialysis blood samples has not been described. Methods We used data from 366 dialysis sessions characterized during follow-up month 4 of the HEMO study, during which cross-dialyzer clearances for both urea and creatinine were available. Blood samples taken at 1 h into dialysis and 30 min and 60 min after dialysis were used to determine how well a two-pool kinetic model could predict creatinine concentrations and other kinetic parameters, including the creatinine generation rate. An extrarenal creatinine clearance of 0.038 l/kg/24 h was included in the model. Results Diffusive cross-dialyzer clearances of urea [230 (SD 37 mL/min] correlated well (R2 = 0.78) with creatinine clearances [164 (SD 30) mL/min]. When the effective diffusion volume flow rate was set at 0.791 times the blood flow rate for the cross-dialyzer clearance measurements at 1 h into dialysis, the mean calculated volume of creatinine distribution averaged 29.6 (SD 7.2) L], compared with 31.6 (SD 7.0) L for urea (P < 0.01). The modeled creatinine generation rate [1183 (SD 463) mg/day] averaged 100.1 % (SD 29; median 99.3) of that predicted in nondialysis patients by an anthropometric equation. A simplified method for modeling the creatinine generation rate using the urea distribution volume and urea dialyzer clearance without use of the postdialysis serum creatinine measurement gave results for creatinine generation rate [1187 (SD 475) mg/day; that closely matched the value calculated using the formally modeled value, R2 = 0.971]. Conclusions Our analysis confirms previous findings of similar distribution volumes for creatinine and urea. After taking extra-renal clearance into consideration, the creatinine generation rate in dialysis patients is similar to that in nondialysis patients. A simplified method based on urea clearance and urea distribution volume not requiring a postdialysis serum creatinine measurement can be used to yield creatinine generation rates that closely match those determined from standard modeling.
Collapse
|
43
|
Interventions to improve hemo dialysis adequacy: protocols based on real-time monitoring of dialysate solute clearance. Clin Kidney J 2017; 11:394-399. [PMID: 29942505 PMCID: PMC6007261 DOI: 10.1093/ckj/sfx110] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2016] [Accepted: 08/28/2017] [Indexed: 11/22/2022] Open
Abstract
Background The monitoring of dialysate ultraviolet (UV) absorbance is a validated technology to measure hemodialysis adequacy and allows for continuous and real-time tracking every session as opposed to the typical once-monthly assessments. Clinical care guidelines are needed to interpret the findings so as to troubleshoot problematic absorbance patterns and intervene during an individual treatment as needed. Methods When paired with highly structured clinical care protocols that allow autonomous nursing actions, this technology has the potential to improve treatment outcomes. These devices measure the UV absorbance of dialysate solutes to calculate and then display the delivered as well as predicted clearance for that session. Various technical factors can affect the course of dialysate absorbance, confound the device’s readout of clearance results and thus lead to challenges for the dialysis unit staff to properly monitor dialysis adequacy. We analyze optimal and problematic patterns to the device’s ‘clearance’ display (e.g. due to thrombosis of hollow fibers, inadequate access blood flow or recirculation) and provide specific interventions to ensure delivery of an adequate dialysis dose. A rigorous algorithm is presented with representative device monitor display profiles from actual hemodialysis sessions. Procedural rationale and interventions are described for each individual scenario. Conclusion Real-time hemodialysate UV absorbance patterns can be used for protocol-based intradialytic interventions to optimize solute clearance.
Collapse
|
44
|
The variable target model: a paradigm shift in the incremental haemodialysis prescription. Nephrol Dial Transplant 2017; 32:182-190. [PMID: 27742823 DOI: 10.1093/ndt/gfw339] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2016] [Accepted: 08/01/2016] [Indexed: 11/15/2022] Open
Abstract
Background The recent interest in incremental haemodialysis (HD) is hindered by the current prescription based on a fixed target model (FTM) for the total (dialytic + renal) equivalent continuous clearance (ECC). The latter is expressed either as standard Kt/V (stdKt/V), i.e. the pre-dialysis averaged concentration of urea-based ECC, or EKRc, i.e. the time averaged concentration-based ECC, corrected for volume (V) = 40 L. Accordingly, there are two different targets: stdKt/V = 2.3 volumes per week (v/wk) and EKRc = 13 mL/min/40 L. However, fixing the total ECC necessarily implies perfect equivalence of its components-the residual renal urea clearance (Kru) and dialysis clearance (Kd). This assumption is wrong because Kru has much greater clinical weight than Kd. Here we propose that the ECC target varies as an inverse function of Kru, from a maximum value in anuria to a minimum value at Kru levels not yet requiring dialysis. The aim of the present study was to compare the current FTM with the proposed variable target model (VTM). Methods The double pool urea kinetic model was used to model dialysis sessions for 360 virtual patients and establish equations predicting the ECC as a function of Kd, Kru and the number of sessions per week. An end-dialysis urea distribution V of 35 L (corresponding to a body surface area of 1.73 m 2 ) was used, so that the current EKRc target of 13 mL/min/40 L could be recalculated at an EKRc 35 value of 12 mL/min/35 L equal to 12 mL/min/1.73 m 2 . The latter also coincides with the maximum value of the EKRc 35 variable target in anuria. The minimum target value of EKRc 35 was assumed to coincide with Kru corrected for V = 35 L (i.e. Krc 35 = 6 mL/min/1.73 m 2 ). The corresponding target for stdKt/V was assumed to vary from 2.3 v/wk at Krc 35 = 0 to 1.7 v/wk at Krc 35 = 6 mL/min/1.73 m 2 . On this basis, the variable target values can be obtained from the following linear equations: target EKRc 35 = 12 - Krc 35 ; target stdKt/V = 2.3 - 0.1 × Krc 35 . Two versions of stdKt/V were considered: the classic version (stdKt/V Gotch ) with Kru at 70%, and the current version (stdKt/V Daug ) with Kru at 100%. Results The VTM with stdKt/V Gotch produces results very close to those using the FTM with stdKt/V Daug . Once-weekly HD is virtually not allowed by the FTM. In contrast, the VTM allows dialysis to start at Krc 35 ∼5 mL/min/1.73 m 2 on a once-weekly HD schedule, at least in relatively healthy patients; this schedule can be maintained until Krc 35 falls below 4 mL/min/1.73 m 2 , at which point the schedule should be changed to a twice-weekly HD schedule, that, in turn, could be maintained until Krc 35 falls below 2 mL/min/1.73 m 2 . Conclusions A paradigm shift from the FTM to the VTM in the prescription of incremental HD is proposed, whereby the VTM would allow less frequent treatments at lower Kru, with important clinical and economic implications. This approach is likely to be safe but needs to be confirmed by randomized controlled trials.
Collapse
|
45
|
Comparison of Complications of Arteriovenous Fistula with Permanent Catheter in Hemodialysis Patients: A Six-month Follow-up. Adv Biomed Res 2017; 6:106. [PMID: 28904934 PMCID: PMC5590397 DOI: 10.4103/2277-9175.213666] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Background: Arteriovenous fistula (AVF), permanent catheter (PC), and vascular graft are three vascular access types used for hemodialysis procedure. Due to insufficient reliable information on the comparison between AVF and PC, this study was conducted to compare AVF and PC regarding dialysis adequacy. Materials and Methods: This prospective study was carried out from March, 2013 to September, 2013. In this study, 76 hemodialysis patients were enrolled and assigned to two unequal groups of AVF and PC. Before and after the dialysis session, blood samples were taken for laboratory examinations and measurement of urea reduction ratio (URR) and Kt/V. The patients were followed up for six months, and then laboratory examinations were repeated. Results: Of the 76 hemodialysis patients, 30 had AVF and others PC. During the 6-month follow-up, 24 patients in PC group but only one patient in AVF group showed infection (P = 0.006), while in each group, three cases of thrombosis were seen (P = 0.58); however, catheter dysfunction was seen in 13 patients of PC group but no patients of AVF group (P = 0.004). There was no difference between the two groups in Kt/V and URR at the beginning of the study; however, after six months, Kt/V and URR were greater in AVF group (P < 0.05). Conclusions: In addition to some advantages of AVF over PC, such as lower rate of infection and thrombosis, we also found better dialysis adequacy in AVF group. We recommend that AVF be created in all of patients with chronic kidney disease who are candidates for hemodialysis.
Collapse
|
46
|
Impact of using two dialyzers in parallel on phosphate clearance in hemodialysis patients: a randomized trial. Nephrol Dial Transplant 2017; 32:855-861. [PMID: 27190374 DOI: 10.1093/ndt/gfw085] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2015] [Accepted: 03/20/2016] [Indexed: 11/14/2022] Open
Abstract
Background Dietary restriction and phosphate binders are the main interventions used to manage hyperphosphatemia in people on hemodialysis, but have limited efficacy. Modifying conventional dialysis regimens to enhance phosphate clearance as an alternative approach remains relatively unstudied. Methods This was a 10-week, 2-arm, randomized crossover study. Participants were prevalent dialysis patients ( n = 32) with consecutive serum phosphate levels >1.6 mmol/L and on stable doses of a phosphate binder. Following a 2-week run-in period, participants were randomized to initiate dialysis using two high flux dialyzers in parallel (blood flow ≥350 mL/min, dialysate flow 800 mL/min) or standard dialysis using one high flux dialyzer (blood flow ≥350 mL/min, dialysate flow of 800 mL/min). Each regimen was 3 weeks in duration. After a 2-week washout period, participants received the alternate regimen. The primary outcome was the mean difference in phosphate clearance by dialyzer strategy. Secondary outcomes were phosphate removal and pre-dialysis serum phosphate. Results Phosphate clearance for the double dialyzer strategy did not differ significantly from the single dialyzer strategy [mean difference 7.5 mL/min (95% confidence interval, 95% CI, -6.1, 21.0), P = 0.28]. There was no difference in total phosphate removal and pre-dialysis phosphate between the double and single dialyzer strategies [total phosphate removal mean difference -0.2 mmol (95% CI -4.1, 3.7), P = 0.93; pre-dialysis mean difference 0.01 mmol/L (95% CI -0.18, 0.21), P = 0.88]. There was no difference in the proportion of participants who experienced at least one episode of intradialytic hypotension (32 versus 47%, P = 0.13). A limitation of the study was frequent protocol deviations in the dialysis prescription. Conclusions In this study, the use of two dialyzers in parallel did not increase phosphate clearance, phosphate removal or pre-dialysis serum phosphorus when compared with a standard dialysis treatment strategy. Future studies should continue to evaluate novel methods of phosphate removal using conventional hemodialysis.
Collapse
|
47
|
|
48
|
Future Avenues to Decrease Uremic Toxin Concentration. Am J Kidney Dis 2015; 67:664-76. [PMID: 26500179 DOI: 10.1053/j.ajkd.2015.08.029] [Citation(s) in RCA: 65] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2015] [Accepted: 08/19/2015] [Indexed: 01/13/2023]
Abstract
In this article, we review approaches for decreasing uremic solute concentrations in chronic kidney disease and in particular, in end-stage renal disease (ESRD). The rationale to do so is the straightforward relation between concentration and biological (toxic) effect for most toxins. The first section is devoted to extracorporeal strategies (kidney replacement therapy). In the context of high-flux hemodialysis and hemodiafiltration, we discuss increasing dialyzer blood and dialysate flows, frequent and/or extended dialysis, adsorption, bioartificial kidney, and changing physical conditions within the dialyzer (especially for protein-bound toxins). The next section focuses on the intestinal generation of uremic toxins, which in return is stimulated by uremic conditions. Therapeutic options are probiotics, prebiotics, synbiotics, and intestinal sorbents. Current data are conflicting, and these issues need further study before useful therapeutic concepts are developed. The following section is devoted to preservation of (residual) kidney function. Although many therapeutic options may overlap with therapies provided before ESRD, we focus on specific aspects of ESRD treatment, such as the risks of too-strict blood pressure and glycemic regulation and hemodynamic changes during dialysis. Finally, some recommendations are given on how research might be organized with regard to uremic toxins and their effects, removal, and impact on outcomes of uremic patients.
Collapse
|
49
|
Low-Sodium Versus Standard-Sodium Peritoneal Dialysis Solution in Hypertensive Patients: A Randomized Controlled Trial. Am J Kidney Dis 2015; 67:753-61. [PMID: 26388284 DOI: 10.1053/j.ajkd.2015.07.031] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2014] [Accepted: 07/27/2015] [Indexed: 12/30/2022]
Abstract
BACKGROUND Peritoneal dialysis (PD) solutions with reduced sodium content may have advantages for hypertensive patients; however, they have lower osmolarity and solvent drag, so the achieved Kt/Vurea may be lower. Furthermore, the increased transperitoneal membrane sodium gradient can influence sodium balance with consequences for blood pressure (BP) control. STUDY DESIGN Prospective, randomized, double-blind clinical trial to prove the noninferiority of total weekly Kt/Vurea with low-sodium versus standard-sodium PD solution, with the lower confidence limit above the clinically accepted difference of -0.5. SETTING & PARTICIPANTS Hypertensive patients (≥ 1 antihypertensive drug, including diuretics, or office systolic BP ≥ 130 mmHg) on continuous ambulatory PD therapy from 17 sites. INTERVENTION 108 patients were randomly assigned (1:1) to 6-month treatments with either low-sodium (125 mmol/L of sodium; 1.5%, 2.3%, or 4.25% glucose; osmolarity, 338-491 mOsm/L) or standard-sodium (134 mmol/L of sodium; 1.5%, 2.3%, or 4.25% glucose; osmolarity, 356-509 mOsm/L) PD solution. OUTCOMES Primary end point: weekly total Kt/Vurea; secondary outcomes: BP control, safety, and tolerability. MEASUREMENTS Total Kt/Vurea was determined from 24-hour dialysate and urine collection; BP, by office measurement. RESULTS Total Kt/Vurea after 12 weeks was 2.53 ± 0.89 in the low-sodium group (n = 40) and 2.97 ± 1.58 in the control group (n = 42). The noninferiority of total Kt/Vurea could not be confirmed. There was no difference for peritoneal Kt/Vurea (1.70 ± 0.38 with low sodium, 1.77 ± 0.44 with standard sodium), but there was a difference in renal Kt/Vurea (0.83 ± 0.80 with low sodium, 1.20 ± 1.54 with standard sodium). Mean daily sodium removal with dialysate at week 12 was 1.188 g higher in the low-sodium group (P < 0.001). BP changed marginally with standard-sodium solution, but decreased with low-sodium PD solution, resulting in less antihypertensive medication. LIMITATIONS Broader variability of study population than anticipated, particularly regarding residual kidney function. CONCLUSIONS The noninferiority of the low-sodium PD solution for total Kt/Vurea could not be proved; however, it showed beneficial clinical effects on sodium removal and BP.
Collapse
|
50
|
How much is enough? An investigation of the relationship between haemo dialysis adequacy and quality of life of elderly patients. Nephrology (Carlton) 2015; 21:314-20. [PMID: 26369623 DOI: 10.1111/nep.12594] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2015] [Revised: 08/13/2015] [Accepted: 08/15/2015] [Indexed: 11/28/2022]
Abstract
AIM The average age of patients requiring haemodialysis is on the rise and has resulted in an increase in the number of elderly people receiving dialysis. While haemodialysis is one of the treatment options for this patient group, questions about its effectiveness have been raised. A second question centres on how much haemodialysis is actually needed to maintain quality of life (QoL). This study examined the relationship between dialysis adequacy and the QoL of elderly patients on haemodialysis. METHOD A prospective cohort of 40 haemodialysis patients aged 75 years and above was recruited and studied over 3 months. Quality of life was assessed with the European Quality of Life-5 Dimensions questionnaire and dialysis adequacy with the urea reduction ratio (URR), and the relationship between the two examined using a simple linear regression model. RESULTS The average age of the participants was 79.8 ± (3.9 years; 45% were women, and diabetes was the main cause of kidney disease (42.5%). The mean URR, visual analogue scale, European Quality of Life-5 Dimensions indices score and Charlson comorbidity index scores were 78.1 ± (5.5)%, 65.4 ± (13.7)%, 0.7 ± (0.27) and 6.3 ± (2.15), respectively. There was no clear relationship between dialysis adequacy and QoL, r = 0.093. Dialysis adequacy did not significantly predict QoL (P = 0.09). CONCLUSION There was no evidence for an association between haemodialysis adequacy and QoL in elderly patients receiving haemodialysis across a URR range of 64.0% to 88.9%. Attempts to improve dialysis adequacy beyond these levels may not be necessary for maintaining the QoL of elderly patients on dialysis. KEY MESSAGE Modern therapy should embrace the concept of quality of life and focus more on symptom relief and optimization of self-management skills to improve the well-being of the elderly patients with ESKD.
Collapse
|