1
|
Durable and Robust Antibacterial Polypropylene Hernia Mesh for Abdominal Wall Defect Repair. ACS APPLIED MATERIALS & INTERFACES 2024; 16:25686-25697. [PMID: 38739862 DOI: 10.1021/acsami.4c02151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2024]
Abstract
Polypropylene (PP) mesh is commonly used in repairing abdominal wall hernia (AWH). However, the use of synthetic prosthesis comes with the risk of developing a prosthetic infection, resulting in delayed healing, secondary surgery, and potentially increased mortality. To address these issues, a facile surface functionalization strategy for PP mesh based on phytic acid (PA) and polyhexamethylene guanidine (PHMG) was constructed through a one-step co-deposition process, referred to as the PA/PHMG coating. The development of PA/PHMG coating is mainly attributed to the surface affinity of PA and the electrostatic interactions between PA and PHMG. The PA/PHMG coating could be completed within 4 h under mild conditions. The prepared PA/PHMG coatings on PP mesh surfaces exhibited desirable biocompatibility toward mammalian cells and excellent antibacterial properties against the notorious "superbug" methicillin-resistant Staphylococcus aureus (MRSA) and tetracycline-resistant Escherichia coli (TRE). The PA/PHMG-coated PP meshes showed killing ratios of over 99% against MRSA in an infected abdominal wall hernia repair model. Furthermore, histological and immunohistochemical analysis revealed a significantly attenuated degree of neutrophil infiltration in the PA/PHMG coating group, attributed to the decreased bacterial numbers alleviating the inflammatory response at the implant sites. Meanwhile, the pristine PP and PA/PHMG-coated meshes showed effective tissue repair, with the PA/PHMG coating group exhibiting enhanced angiogenesis compared with pristine PP meshes, suggesting superior tissue restoration. Additionally, PP meshes with the highest PHMG weight ratio (PA/PHMG(3)) exhibited excellent long-term robustness under phosphate-buffered saline (PBS) immersion with a killing ratio against MRSA still exceeding 95% after 60 days of PBS immersion. The present work provides a facile and promising approach for developing antibacterial implants.
Collapse
|
2
|
Shape-Configurable Mesh for Hernia Repair by Synchronizing Anisotropic Body Motion. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2303325. [PMID: 37490554 DOI: 10.1002/smll.202303325] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2023] [Revised: 06/27/2023] [Indexed: 07/27/2023]
Abstract
Continuous progress has been made in elucidating the relationship between material property, device design, and body function to develop surgical meshes. However, an unmet need still exists wherein the surgical mesh can handle the body motion and thereby promote the repair process. Here, the hernia mesh design and the advanced polymer properties are tailored to synchronize with the anisotropic abdominal motion through shape configuration. The thermomechanical property of shape configurable polymer enables molding of mesh shape to fit onto the abdominal structure upon temperature shift, followed by shape fixing with the release of the heat energy. The microstructural design of mesh is produced through finite element modeling to handle the abdominal motion efficiently through the anisotropic longitudinal and transverse directions. The design effects are validated through in vitro, ex vivo, and in vivo mechanical analyses using a self-configurable, body motion responsive (BMR) mesh. The regenerative function of BMR mesh leads to effective repair in a rat hernioplasty model by effectively handling the anisotropic abdomen motion. Subsequently, the device-tissue integration is promoted by promoting healthy collagen synthesis with fibroblast-to-myofibroblast differentiation. This study suggests a potential solution to promote hernia repair by fine-tuning the relationship between material property and mesh design.
Collapse
|
3
|
Silk Meshes Coated with Chitosan-Bioactive Phytochemicals Activate Wound Healing Genes In Vitro. Macromol Biosci 2023; 23:e2300039. [PMID: 37203244 DOI: 10.1002/mabi.202300039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Revised: 04/15/2023] [Indexed: 05/20/2023]
Abstract
Meshes from natural silk are hand knitted and surface functionalized to facilitate hernia repair and other load bearing, tissue applications. Purified organic silk is - hand knitted and then coated with chitosan (CH)/bacterial cellulose (BC) blend polymer using four phytochemicals such as pomegranate (PG) peel, Nigella sativa (NS) seed, Licorice root (LE), and Bearberry leaf extracts (BE) separately. Characterizations using GCMS analysis shows the presence of bioactive chemicals in the extracts. Scanning electron microcopy (SEM) shows that the surface is coated with the composite polymer t. Fourier transform infrared spectroscopy (FTIR) shows significant elements found in CH, BC, and phytochemicals in plant extracts with no chemical changes. Tensile strength of the coated meshes is higher to support tissue as implants. The release kinetics suggest sustained release of phytochemical extracts. In vitro studies confirmed the noncytotoxic, biocompatible, wound healing potential of the meshes. Furthermore, gene expression analysis of 3-wound healing genes shows marked increase in the in vitro cell cultures due to the presence of extracts. These results suggest that the composite meshes can efficiently support hernia closure while facilitating wound/tissue healing and combating bacterial infections. Therefore, these meshes can be good candidates for fistula and cleft palate repair.
Collapse
|
4
|
Comparative Study of Self-Gripping Mesh vs. Polypropylene Mesh in Lichtenstein's Open Inguinal Hernioplasty. Cureus 2023; 15:e43652. [PMID: 37727163 PMCID: PMC10506370 DOI: 10.7759/cureus.43652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 08/17/2023] [Indexed: 09/21/2023] Open
Abstract
Background Inguinal hernia is one of the most common conditions in India, and history has many repair techniques recorded in it. Postoperative pain still remains a problem despite tension-free hernioplasty being accepted as the gold standard. Increased duration of surgery not only exposes the patient to unwanted increased chances of mesh infection but also reduces the surgeon's productivity if continued persistently. In this study, the main aim was to compare the fixation techniques of polypropylene mesh vs. self-gripping mesh in inguinal hernia surgery in terms of duration of surgery, postoperative pain, seroma, recurrence, foreign body sensation, and wound infections. Methods It is a prospective, comparative, and quantitative study conducted at Sri Ramachandra Institute of Higher Education and Research in the Department of General Surgery. Patients presenting with inguinal hernia to the OPD were included in the study. The sampling technique used in this study is simple, convenient sampling. As a result, the calculation of the margin of error and confidence levels may be difficult. Nevertheless, the sample accurately represents the population. Patients were divided into two groups: the study group (25), patients undergoing hernioplasty with self-gripping mesh, and the control group (25), patients undergoing hernioplasty with polypropylene mesh using conventional suturing. The duration of surgery, postoperative pain, seroma, recurrence, foreign body sensation, and wound infections were compared and analyzed between the two groups. Results In this study, the duration of surgery was less than one hour for three patients (12%) in the control group (polypropylene), compared to 13 (52%) patients in the study group (self-gripping), which is statistically significant. The early postoperative pain on POD 0 was greater than 4 (visual analogue score) in 8 (32%) patients in the control group and two (8%) patients in the study group. There were no significant differences in chronic pain, recurrence rate, seroma rate, or wound infection between the two groups. Conclusions In our study, we conclude that self-gripping mesh is superior to polypropylene mesh in surgery of inguinal hernia in terms of shorter duration of surgery. There is also reduced pain in the immediate postoperative period though not statistically significant. There is no significant difference in both the groups in terms of seroma formation, wound infection, foreign body sensation, and recurrence.
Collapse
|
5
|
Trends in Incisional and Ventral Hernia Repair: A Population Analysis From 2001 to 2021. Cureus 2023; 15:e35744. [PMID: 36879583 PMCID: PMC9984720 DOI: 10.7759/cureus.35744] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/03/2023] [Indexed: 03/06/2023] Open
Abstract
Background Incisional and ventral hernias are highly prevalent, with primary ventral hernias occurring in approximately 20% of adults and incisional hernias developing in up to 30% of midline abdominal incisions. Recent data from the United States have shown an increasing incidence of elective incisional and ventral hernia repair (IVHR) and emergency repair of complicated hernias. This study examines Australian population trends in IVHR over a two-decade study period. Methods This retrospective study was performed using procedure data from the Australian Institute of Health and Welfare and population data from the Australian Bureau of Statistics captured between 2000 and 2021 to calculate incidence rates per 100,000 population by age and sex for selected subcategories of IVHR operations. Trends over time were evaluated using simple linear regression. Results There were 809,308 IVHR operations performed in Australia during the study period. The cumulative incidence adjusted for population was 182 per 100,000; this increased by 9.578 per year during the study period (95%CI = 8.431-10.726, p<.001). IVHR for primary umbilical hernias experienced the most significant increase in population-adjusted incidence, 1.177 per year (95%CI = 0.654-1.701, p<.001). Emergency IVHR for incarcerated, obstructed, and strangulated hernias increased by 0.576 per year (95%CI = 0.510-0.642, p<.001). Only 20.2% of IVHR procedures were performed as day surgery. Conclusions Australia has seen a significant increase in IVHR operations performed in the last 20 years, particularly those for primary ventral hernias. IVHR for hernias complicated by incarceration, obstruction, and strangulation also increased significantly. The proportion of IVHR operations performed as day surgery is well below the target set by the Royal Australasian College of Surgeons. With the increasing incidence of IVHR operations and an increasing proportion of these being emergent, elective IVHR should be performed as day surgery when it is safe.
Collapse
|
6
|
[Safety of mesh with fluoropolymer coating during intra-abdominal placement in large animals: results of the pilot study]. Khirurgiia (Mosk) 2023:43-58. [PMID: 36748870 DOI: 10.17116/hirurgia202302143] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
OBJECTIVE When performing laparoscopic intraperitoneal hernioplasty (IPOM), endoprostheses made of fluoropolymers are often used. However, there is no data in the literature on the intra-abdominal use of inexpensive polyester prostheses with a fluoropolymer coating compared to composite implants. Thus, the aim of the pilot study was a preliminary assessment of the safety profile of FTOREX mesh endoprostheses during intra-abdominal placement in large animals. MATERIAL AND METHODS 6 endoprostheses were installed laparoscopically intraperitoneally in each of the 3 pigs: 1) FTOREX; 2) FTOREX with a layer of carboxymethylcellulose; 3) REPEREN-16-2; 4) SYMBOTEX; 5) VENTRALIGHT ST; 6) decellularized pork peritoneum. Fixation was performed with a herniator, transfascial sutures were not used. Relaparoscopy was performed after 45 days, and withdrawal from the experiment was performed after 90 days. Performance characteristics, signs of deformation and retraction, parameters of spike formation were evaluated. RESULTS All the animals survived, no complications were observed. There were no clinical manifestations or behavioral reactions indicating the presence of adhesions. The most convenient to use were the SYMBOTEX and FTOREX implants (5.0 points each). By the end of the experiment, deformation and retraction were noted in both variants of the FTOREX implants and the REPEREN prosthesis. These changes were completely absent only when using the SYMBOTEX endoprosthesis. According to the number of implants with adhesions, by the end of the observation, both variants of FTOREX prostheses occupied an intermediate position between the Reference (the worst indicator) and VENTRALIGHT ST (the best indicator). However, both FTOREX endoprostheses showed the best performance among all implants in the integral assessment of adhesions, as well as in terms of parameters such as the area and appearance of adhesions, and in terms of the strength of the joints, they were second only to the VENTRALIGHT ST endoprosthesis (0.67 vs. 0.5 points). During the study, there was no reliable dependence of deformation, retraction and adhesion formation indicators on the type of implant. CONCLUSION The results of the pilot study showed that all the implants used did not cause any clinically significant adverse reactions or complications. FTOREX endoprostheses with their intraperitoneal installation have anti-adhesive properties that are not inferior to VENTRALIGHT ST or SYMBOTEX composite implants. However, having less rigidity, they are more often deformed and subjected to retraction.
Collapse
|
7
|
Patients With Systemic Reaction to Their Hernia Mesh: An Introduction to Mesh Implant Illness. JOURNAL OF ABDOMINAL WALL SURGERY : JAWS 2023; 2:10983. [PMID: 38312397 PMCID: PMC10831643 DOI: 10.3389/jaws.2023.10983] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Accepted: 01/16/2023] [Indexed: 02/06/2024]
Abstract
In our practice, we have noticed an increased number of patients requiring mesh removal due to a systemic reaction to their implant. We present our experience in diagnosing and treating a subpopulation of patients who require mesh removal due to a possible mesh implant illness (MII). All patients who underwent mesh removal for indication of mesh reaction were captured from a hernia database. Data extraction focused on the patients' predisposing medical conditions, presenting symptoms suggestive of mesh implant illness, types of implants to which reaction occurred, and postoperative outcome after mesh removal. Over almost 7 years, 165 patients had mesh removed. Indication for mesh removal was probable MII in 28 (17%). Most were in females (60%), average age was 46 years, with average pre-operative pain score 5.4/10. All patients underwent complete mesh removal. Sixteen (57%) required tissue repair of their hernia; 4 (14%) had hybrid mesh implanted. Nineteen (68%) had improvement and/or resolution of their MII symptoms within the first month after removal. We present insight into a unique but rising incidence of patients who suffer from systemic reaction following mesh implantation. Predisposing factors include female sex, history of autoimmune disorder, and multiple medical and environmental allergies and sensitivities. Presenting symptoms included spontaneous rashes, erythema and edema over the area of implant, arthralgia, headaches, and chronic fatigue. Long-term follow up after mesh removal confirmed resolution of symptoms after mesh removal. We hope this provides greater attention to patients who present with vague, non-specific but debilitating symptoms after mesh implantation.
Collapse
|
8
|
[Histological changes in intraperitoneal onlay mesh (IPOM) with synthetic and biological meshes. Results of the chronic experiment]. Khirurgiia (Mosk) 2023:37-50. [PMID: 37379404 DOI: 10.17116/hirurgia202307137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/30/2023]
Abstract
OBJECTIVE The objective of the study was to analyze histological changes in the site of the meshes FTOREX, FTOREX coated with carboxymethylcellulose, Ventralight ST, Symbotex, REPEREN-16-2 and decellularized porcine peritoneum on the parietal peritoneum of the pig. MATERIAL AND METHODS At laparoscopy, 6 different meshes were placed intraperitoneally in each of the 3 pigs. After 90 days, the animals were taken out of the experiment. After staining with hematoxylin and eosin, quantitative morphometry and counting the number of vessels and cells in the interstitium in the areas of the mesh and peritoneum were performed. An immunohistochemical study with an antibody to pancytokeratins assessed the state of the initial peritoneum and neoperitoneum. RESULTS According to morphological characteristics, the meshes were divided into 3 groups: 1) with fluoropolymer coating FTOREX, 2) Ventralight ST and Symbotex, 3) REPEREN and decellularized peritoneum. In group 1, the surface area of the mesh threads was optimal in terms of the arrangement and arrangement of the threads relative to each other. This contributed to the formation of a relatively dense fibrous framework and a place to preserve the underlying peritoneum involved in the formation of the neoperitoneum. Despite the smallest surface area of the threads, in group 3, the greatest fibroblastic reaction was noted. Inflammatory changes were the least pronounced in group 1. They were the greatest in group 3, where there was a pronounced leukocyte reaction, combined with the processes of metaplasia, the development of fibrinoid necrosis, and the progression of the secondary inflammatory process. In group 1, the optimal ratio of newly formed vessels was noted, in group 2 - veins prevailed over arteries, in group 3 - the number of vessels was minimal. Immunohistochemical study showed that in group 1, mesothelial cells covered almost the entire surface of the implant, and there were also areas of preserved basic peritoneum. In group 2, mesothelium also covered most of the surface of the meshes, but the underlying peritoneum was absent. In group 3, on the contrary, a significant number of extended areas not covered with mesothelium were revealed. CONCLUSION The conducted morphological and morphometric study showed that the most balanced ratio of the components of the newly formed fibrous tissue and blood vessels is observed when using implants with a fluoropolymer coating FTOREX. At the same time, the remaining basic peritoneum actively participated in the formation of the neoperitoneum. The Ventralight ST and Symbotex meshes also contributed to the formation of a full-fledged fibrous tissue and adequate vascular proliferation, however, they prevented the preservation of the underlying peritoneum, which practically excluded its participation in the formation of the neoperitoneum. The REPEREN mesh and decellularized porcine peritoneum led to the least balanced cell and vascular proliferation and the greatest fibroplastic reaction, which could further negatively affect the state of the formed scar.
Collapse
|
9
|
Plasma-Induced Diallyldimethylammonium Chloride Antibacterial Hernia Mesh. ACS APPLIED BIO MATERIALS 2022; 5:5645-5656. [PMID: 36446396 DOI: 10.1021/acsabm.2c00695] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/05/2022]
Abstract
A hernia is a pathological condition caused by a defect or opening in the muscle wall, which leads to organs pushing through the opening or defect. Hernia recurrence, seroma, persistent pain, tissue adhesions, and wound infection are common complications following hernia repair surgery. Infection after hernia mesh implantation is the third major complication leading to hernia recurrence. In order to reduce the incidence of late infections, we developed a polypropylene mesh with antibacterial properties. In this study, knitted polypropylene meshes were exposed to radio-frequency plasma to activate their surfaces. The antibacterial monomer diallyldimethylammonium chloride (DADMAC) was then grafted onto the mesh surface using pentaerythritol tetraacrylate as the cross-linker since it is able to engage all four functional groups to form a high-density cross-linked network. The subsequent antibacterial performance showed a 2.9 log reduction toward Staphylococcus aureus and a 0.9 log reduction for Escherichia coli.
Collapse
|
10
|
In Vitro Cytotoxicity, Colonisation by Fibroblasts and Antimicrobial Properties of Surgical Meshes Coated with Bacterial Cellulose. Int J Mol Sci 2022; 23:ijms23094835. [PMID: 35563224 PMCID: PMC9105287 DOI: 10.3390/ijms23094835] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2022] [Revised: 04/22/2022] [Accepted: 04/25/2022] [Indexed: 02/04/2023] Open
Abstract
Hernia repairs are the most common abdominal wall elective procedures performed by general surgeons. Hernia-related postoperative infective complications occur with 10% frequency. To counteract the risk of infection emergence, the development of effective, biocompatible and antimicrobial mesh adjuvants is required. Therefore, the aim of our in vitro investigation was to evaluate the suitability of bacterial cellulose (BC) polymer coupled with gentamicin (GM) antibiotic as an absorbent layer of surgical mesh. Our research included the assessment of GM-BC-modified meshes’ cytotoxicity against fibroblasts ATCC CCL-1 and a 60-day duration cell colonisation measurement. The obtained results showed no cytotoxic effect of modified meshes. The quantified fibroblast cells levels resembled a bimodal distribution depending on the time of culturing and the type of mesh applied. The measured GM minimal inhibitory concentration was 0.47 µg/mL. Results obtained in the modified disc-diffusion method showed that GM-BC-modified meshes inhibited bacterial growth more effectively than non-coated meshes. The results of our study indicate that BC-modified hernia meshes, fortified with appropriate antimicrobial, may be applied as effective implants in hernia surgery, preventing risk of infection occurrence and providing a high level of biocompatibility with regard to fibroblast cells.
Collapse
|
11
|
Latest Trends on the Attenuation of Systemic Foreign Body Response and Infectious Complications of Synthetic Hernia Meshes. ACS APPLIED BIO MATERIALS 2022; 5:1-19. [PMID: 35014826 DOI: 10.1021/acsabm.1c00841] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Throughout the past few years, hernia incidence has remained at a high level worldwide, with more than 20 million people requiring hernia surgery each year. Synthetic hernia meshes play an important role, providing a microenvironment that attracts and harbors host cells and acting as a permanent roadmap for intact abdominal wall reconstruction. Nevertheless, it is still inevitable to cause not-so-trivial complications, especially chronic pain and adhesion. In long-term studies, it was found that the complications are mainly caused by excessive fibrosis from the foreign body reaction (FBR) and infection resulting from bacterial colonization. For a thorough understanding of their complex mechanism and providing a richer background for mesh development, herein, we discuss different clinical mesh products and explore the interactions between their structure and complications. We further explored progress in reducing mesh complications to provide varied strategies that are informative and instructive for mesh modification in different research directions. We hope that this work will spur hernia mesh designers to step up their efforts to develop more practical and accessible meshes by improving the physical structure and chemical properties of meshes to combat the increasing risk of adhesions, infections, and inflammatory reactions. We conclude that further work is needed to solve this pressing problem, especially in the analysis and functionalization of mesh materials, provided of course that the initial performance of the mesh is guaranteed.
Collapse
|
12
|
Different etiopathogeneses in early-onset and late-onset inguinal hernia mesh infections in a prospectively evaluated cohort. Acta Chir Belg 2021; 121:164-169. [PMID: 31690215 DOI: 10.1080/00015458.2019.1689648] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
INTRODUCTION Inguinal hernia mesh infection (IHMI) is a rare but a significant problem. The aim of this study was to determine whether etiopathogeneses of early-onset and late-onset IHMIs differ in terms of the origin of infectious agents, and route of dissemination. PATIENTS AND METHODS This was a retrospective cohort study with prospective data collection of patients operated on from 2013 to 2015. Early-onset IHMI was defined as symptoms developed within one year after the index surgery, whereas late-onset IHMI was defined as infection developed later than a year after the index surgery. Age, gender, ASA score, BMI, time from index surgery, isolated infectious agents and possible pathogeneses were analyzed. RESULTS During the study period, 1438 patients underwent inguinal hernia repair. Sixteen patients (1.1%) had IHMI, of whom nine were early-onset and seven late-onset. The groups were comparable for age (p = .54), gender (p = 1.0), BMI (p = .79), and ASA score (p = 1.0). The most common infectious agent in early-onset IHMI was St. aureus, whereas Enterococci and Enterobacter prevailed in late-onset IHMI. The possible pathogenesis of IHMI in seven patients with early-onset IHMI was primary exogenous infection, whereas in patients with late-onset IHMI the pathogenesis might be hematogenous or contact spread. All patients with IHMI underwent mesh removal. In two patients (one from each group), partial mesh removal was performed previously and IHMI recurred. CONCLUSIONS Early-onset hernia mesh infection is mostly caused by St. aureus through exogenous contamination, whereas its late-onset counterpart might be a result of hematogenous or contact spread of intestinal flora.
Collapse
|
13
|
The Grip Concept of Incisional Hernia Repair-Dynamic Bench Test, CT Abdomen With Valsalva and 1-Year Clinical Results. Front Surg 2021; 8:602181. [PMID: 33937312 PMCID: PMC8080034 DOI: 10.3389/fsurg.2021.602181] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Accepted: 02/24/2021] [Indexed: 02/03/2023] Open
Abstract
Incisional hernia is a frequent consequence of major surgery. Most repairs augment the abdominal wall with artificial meshes fixed to the tissues with sutures, tacks, or glue. Pain and recurrences plague at least 10-20% of the patients after repair of the abdominal defect. How should a repair of incisional hernias be constructed to achieve durability? Incisional hernia repair can be regarded as a compound technique. The biomechanical properties of a compound made of tissue, textile, and linking materials vary to a large extent. Tissues differ in age, exercise levels, and comorbidities. Textiles are currently optimized for tensile strength, but frequently fail to provide tackiness, dynamic stiction, and strain resistance to pulse impacts. Linking strength with and without fixation devices depends on the retention forces between surfaces to sustain stiction under dynamic load. Impacts such a coughing or sharp bending can easily overburden clinically applied composite structures and can lead to a breakdown of incisional hernia repair. Our group developed a bench test with tissues, fixation, and textiles using dynamic intermittent strain (DIS), which resembles coughing. Tissue elasticity, the size of the hernia under pressure, and the area of instability of the abdominal wall of the individual patient was assessed with low-dose computed tomography of the abdomen preoperatively. A surgical concept was developed based on biomechanical considerations. Observations in a clinical registry based on consecutive patients from four hospitals demonstrate low failure rates and low pain levels after 1 year. Here, results from the bench test, the application of CT abdomen with Valsalva's maneuver, considerations of the surgical concept, and the clinical application of our approach are outlined.
Collapse
|
14
|
Developing a Hernia Mesh Tissue Integration Index Using a Porcine Model-A Pilot Study. Front Surg 2020; 7:600195. [PMID: 33324674 PMCID: PMC7726018 DOI: 10.3389/fsurg.2020.600195] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2020] [Accepted: 10/13/2020] [Indexed: 11/23/2022] Open
Abstract
Introduction: With so many prosthetics available, it can be difficult for surgeons to choose the most appropriate hernia mesh. Successful hernia repair mandates an understanding of how the patient's inflammatory response influences surgical outcomes. Failure to appreciate the importance of the biological aspect of hernia repair can be very costly as emerging evidence supports that biofilm formation and reduction in effective mesh porosity gives rise to long-term mesh complications including fibrosis, chronic mesh infection, and pain. In this pilot study, we utilized a large animal (porcine) model to develop a numerical Mesh Tissue Integration (MTI) Index focused on visible tissue ingrowth, fibrosis, adhesion formation and resorption of mesh. The aim is to help surgeons adopt an evidence-based approach in selecting the most appropriate mesh according to its tissue ingrowth characteristics, matched to the patient to achieve improved surgical outcomes and optimal patient-centered care. Methods: Two forty kg female Landrace pigs were recruited for this pilot study. A total of eight commonly used hernia mesh products and two controls measuring 5 × 5cm were surgically implanted in subrectus and intraperitoneal planes. The pigs were euthanised at 2 and 4 weeks, respectively. The abdominal wall was explanted, and the mesh specimens underwent macroscopic, histologic and biomechanical analysis, with engineering and pathology teams blinded to the mesh. Results: Significant differences between the degrees of MTI were observed at 2 weeks and the distinctions were even more apparent at 4 weeks. One of the interesting incidental findings we observed is that mesh products placed in the subrectus plane displayed greater degrees of adhesion strength and integration than those placed intraperitoneally. Conclusion: This pilot study is one of the first to propose a functional, biological standardized model for comparing hernia mesh products. The results are encouraging and demonstrate that this is a robust and transferrable model for assessing MTI in hernia mesh. The intention for this model is that it will be utilized synergistically with long term mesh/patient outcome registries and databases to inform improved matching of mesh to patient, particularly in the setting of the complex hernia repair and abdominal wall reconstruction.
Collapse
|
15
|
Abstract
Social media can influence public perception in health care. By 2016, social media discussion against the use of transvaginal mesh influenced changes in Food and Drug Administration (FDA) regulations. We propose that the fate of hernia mesh will follow that of transvaginal mesh. Thus, we compare the trend of social media discussion of hernia and transvaginal mesh. Posts on Twitter and public Facebook groups were tracked for keywords "hernia," "hernia mesh," and "pelvic/vaginal mesh." Posts were categorized based on sentiment. On Facebook, 16 public groups with 14 526 members expressed negative sentiments in 95% of their 750 daily posts. Meanwhile, of the 1.1 million tweets on Twitter, those about hernia mesh were more negative (36.5%) than those about pelvic/vaginal mesh (29.2%). Three of the 5 top tweeters about hernia mesh and pelvic/vaginal mesh were linked to law firms involved in mesh-based lawsuits. The negative sentiments and steering of social media discussion by lawyers may directly affect surgical care. As surgeons, we may adapt our informed consent to acknowledge our patients' apprehensions about mesh. We may also be more involved in social media discussions ourselves. Meanwhile, we await FDA decisions in the regulation and availability of hernia mesh.
Collapse
|
16
|
Abstract
Background: Ventral hernia repair (VHR) is one of the most common general surgery procedures; however, few studies with long-term follow-up of VHR outcomes exist. Methods: We performed a retrospective review of VHRs performed from 2000 to 2009 at a single institution. Our primary outcome was recurrence, and secondary outcomes were reoperations and complications including seroma, hematomas, abdominal wall abscess, wound infections, and mesh infections. Results: Our sample population (n=420; mean age 46.3±11.7 years) included 230 females (54.8%), and cases included laparoscopic (n=31; 7.5%), laparoscopic converted to open (n=7; 1.7%), and open (n=373, 90%). As compared to suture repairs, mesh repair was associated with lower rates of complications (25.7% vs 29.5%, p=0.10) and recurrence (12.8% vs 15.2%, p=0.67). Laparoscopic repairs had lower rates of complications than open repairs (25% vs 26.8%; p=0.70) but similar rates of recurrence (13.8% and 13.6%; p=0.53). After logistic regression, obesity, chronic obstructive pulmonary disease, component separation technique, and prolonged operating time (>75th percentile) were associated with increased complications. Conclusion: Obesity is a modifiable risk factor and must be addressed in patients undergoing VHRs. Mesh repair does not increase the risk of adverse long-term outcomes and may be performed safely in patients undergoing VHR.
Collapse
|
17
|
Stoppa method - forgotten surgery. POLISH JOURNAL OF SURGERY 2017; 89:43-47. [PMID: 29154239 DOI: 10.5604/01.3001.0010.5410] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Stoppa method - forgotten surgery.
Collapse
|
18
|
In vitro analysis of biopolymer coating with glycidoxypropyltrimethoxysilane on hernia meshes. J Biomed Mater Res B Appl Biomater 2016; 105:1083-1090. [PMID: 26991137 DOI: 10.1002/jbm.b.33653] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2015] [Accepted: 02/22/2016] [Indexed: 01/25/2023]
Abstract
Certain coatings may improve the biocompatibility of hernia meshes. The coating with self-assembled monolayers, such as glycidoxypropyltrimethoxysilane (GOPS) can also improve the materials characteristics of implants. This approach was not yet explored in hernia meshes. It was the aim of this work to clarify if and how hernia meshes with their three-dimensional structure can be coated with GOPS and with which technique this coating can be best characterized. Commercially available meshes made from polypropylene (PP), polyester (PE), and expanded polytetrafluorethylene (ePTFE) have been coated with GOPS. The coatings were analyzed via X-ray photoelectron spectroscopy (XPS), confocal laser scanning microscopy (CLSM), and cell proliferation test (mouse fibroblasts). Cell viability and cytotoxicity were tested by MTT test. With the GOPS surface modification, the adherence of mouse fibroblasts on polyester meshes and the proliferation on ePTFE meshes were increased compared to noncoated meshes. Both XPS and CLSM are limited in their applicability and validity due to the three-dimensional mesh structure while CLSM was overall more suitable. In the MTT test, no negative effects of the GOPS coating on the cells were detected after 24 h. The present results show that GOPS coating of hernia meshes is feasible and effective. GOPS coating can be achieved in a fast and cost-efficient way. Further investigations are necessary with respect to coating quality and adverse effects before such a coating may be used in the clinical routine. In conclusion, GOPS is a promising material that warrants further research as coating of medical implants. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1083-1090, 2017.
Collapse
|
19
|
Ewing's sarcoma of the ulna treated with sub-total resection and reconstruction using a non-vascularized, autogenous fibular graft and hernia mesh: A case report. Oncol Lett 2015; 10:2067-2070. [PMID: 26622797 PMCID: PMC4579922 DOI: 10.3892/ol.2015.3534] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2014] [Accepted: 06/22/2015] [Indexed: 11/21/2022] Open
Abstract
Ewing's sarcoma of the bone is the second most frequently occurring malignant bone tumor in children and adolescents. Ewing's sarcoma in the ulna are extremely rare. Thus, the surgical options for reconstruction of the elbow are limited and technically challenging. In the current study, a 29-year-old male with Ewing's sarcoma of the ulna was treated with a sub-total resection and reconstruction using a non-vascularized, autogenous fibular graft and hernia mesh. At the 2-year follow-up, the patient had returned to his previous occupation with no evidence of local recurrence or distant metastasis. The functional recovery was satisfactory, and the patient could perform active movement of the elbow from 0° to 135°, forearm pronation to 30°, supination to 85° and had full hand function. The grip power of the left hand was 36 kg, which was 86% of the contralateral side (42 kg).
Collapse
|
20
|
Complicated acute appendicitis within a right inguinal hernia sac (Amyand's hernia): report of a case. Hippokratia 2014; 18:74-76. [PMID: 25125958 PMCID: PMC4103049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
BACKGROUND The term Amyand's hernia refers to a rare clinical situation characterized by the presence of a normal or inflammed appendix within the sac of an inguinal hernia. The situation may be asymptomatic or may present as an incarcerated hernia in case of strangulation or acute appendicitis occurring inside the hernia sac. DESCRIPTION OF THE CASE We present the case of a right Amyand's hernia on a 88-years-old male that presented to our emergency department with a severely tender and swollen inguinal mass that was diagnosed as a strangulated inguinal hernia - inguinal abcess and underwent emergency operation. The intraoperative findings included a severely inflamed and perforated appendix along with healthy part of the caecum inside the sac. Appendectomy with subsequent primary hernia repair without mesh was performed with excellent outcome. CONCLUSION Because of the fact that most of such rare cases are managed by urgent surgery with no preoperative diagnosis, every surgeon should be prepared for the possibility of coping with such an unexpected situation.
Collapse
|