1
|
Assessing vulnerability to embolism and hydraulic safety margins in reed-like Restionaceae. PLANT BIOLOGY (STUTTGART, GERMANY) 2024. [PMID: 38588329 DOI: 10.1111/plb.13644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2023] [Accepted: 03/12/2024] [Indexed: 04/10/2024]
Abstract
The African Restionaceae (Poales), the dominant graminoid layer in the megadiverse Cape Floristic Region of South Africa, are distributed across a wide range of moisture availability, yet currently there is very little known about the underlying hydraulics of this group. We tested two methods for measuring culm vulnerability to embolism, the optical and pneumatic methods, in three species of Cannomois ranging in habitat from semi-riparian (Cannomois virgata) to dryland (Cannomois parviflora and C. congesta). Estimates of culm xylem vulnerability were coupled with measures of turgor loss point (ΨTLP) and minimum field water potential (ΨMD) to assess hydraulic safety margins. The optical and pneumatic methods produced similar estimates of P50, but differed for P12 and P88. All three species were quite vulnerable to embolism, with P50 of -1.9 MPa (C. virgata), -2.3 MPa (C. congesta), and -2.4 MPa (C. parviflora). Estimates of P50, ΨTLP and ΨMD aligned with habitat moisture stress, with highest values found in the semi-riparian C. virgata. Consistent differences in P50, ΨMD and ΨTLP between species resulted in consistent hydraulic safety margins across species of 0.96 ± 0.1 MPa between ΨMD and P50, with onset of embolism occurring 0.43 ± 0.04 MPa after ΨTLP for all three species. Our study demonstrates that restio occupancy of dry environments involves more than the evolution of highly resistant xylem, suggesting that other aspects of water relations are key to understanding trait-environment relationships in this group.
Collapse
|
2
|
Optical method supported by machine learning for dynamics of C-reactive protein concentrations changes detection in biological matrix samples. JOURNAL OF BIOPHOTONICS 2024:e202300523. [PMID: 38508857 DOI: 10.1002/jbio.202300523] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Subscribe] [Scholar Register] [Received: 12/08/2023] [Revised: 02/14/2024] [Accepted: 03/06/2024] [Indexed: 03/22/2024]
Abstract
In this article we present the novel spectroscopy method supported with machine learning for real-time detection of infectious agents in wastewater. In the case of infectious diseases, wastewater monitoring can be used to detect the presence of inflammation biomarkers, such as the proposed C-reactive protein, for monitoring inflammatory conditions and mass screening during epidemics for early detection in communities of concern, such as hospitals, schools, and so on. The proposed spectroscopy method supported with machine learning for real-time detection of infectious agents will eliminate the need for time-consuming processes, which contribute to reducing costs. The spectra in range 220-750 nm were used for the study. We achieve accuracy of our prediction model up to 68% with using only absorption spectrophotometer and machine learning. The use of such a set makes the method universal, due to the possibility of using many different detectors.
Collapse
|
3
|
The Measurement of Atmospheric Black Carbon: A Review. TOXICS 2023; 11:975. [PMID: 38133376 PMCID: PMC10748019 DOI: 10.3390/toxics11120975] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/10/2023] [Revised: 11/16/2023] [Accepted: 11/28/2023] [Indexed: 12/23/2023]
Abstract
Black Carbon (BC), the second-largest contributor to global warming, has detrimental effects on human health and the environment. However, the accurate quantification of BC poses a significant challenge, impeding the comprehensive assessment of its impacts. Therefore, this paper aims to critically review three quantitative methods for measuring BC: Thermal Optical Analysis (TOA), the Optical Method, and Laser-Induced Incandescence (LII). The determination principles, available commercial instruments, sources of deviation, and correction approaches associated with these techniques are systematically discussed. By synthesizing and comparing the quantitative results reported in previous studies, this paper aims to elucidate the underlying relationships and fundamental disparities among Elemental Carbon (EC), Equivalent Black Carbon (eBC), and Refractory Black Carbon (rBC). Finally, based on the current advancements in BC quantification, recommendations are proposed to guide future research directions.
Collapse
|
4
|
Dimensional Deviations of Horizontal Thin Wall of Titanium Alloy Ti6Al4V Determined by Optical and Contact Methods. MATERIALS (BASEL, SWITZERLAND) 2023; 16:7272. [PMID: 38068016 PMCID: PMC10707711 DOI: 10.3390/ma16237272] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 11/12/2023] [Accepted: 11/18/2023] [Indexed: 01/14/2024]
Abstract
Thin-walled structures are used in many industries. The need to use such elements is dictated by the desire to reduce the weight of the finished product, as well as to reduce its cost. The most common method of machining such elements is the use of milling, which makes it possible to make a product of almost any shape. However, several undesirable phenomena occur during the milling of thin-walled structures. The main phenomenon is a deformation of the thin wall resulting from its reduced stiffness. Therefore, it is necessary to control the dimensional and shape accuracy of finished products, which is carried out using various measuring instruments. The development of newer measuring methods such as optical methods is being observed. One of the newer measuring machines is the 3D optical scanner. In the present experiment, thin-walled samples in horizontal orientation of Ti6Al4V titanium alloy were machined under controlled cutting conditions. During machining, the cutting speed and feed rate were assumed constant, while the input factors were the tool and cutting strategy. This paper presents graphs of deviations in the determined cross-section planes of thin-walled structures using a 3D optical scanner and a coordinate measuring machine. A correlation was made between the results obtained from the measurement by the optical method and those determined by the contact method. A maximum discrepancy of about 8% was observed between the methods used.
Collapse
|
5
|
The optical method based on gas injection overestimates leaf vulnerability to xylem embolism in three woody species. TREE PHYSIOLOGY 2023; 43:1784-1795. [PMID: 37427987 DOI: 10.1093/treephys/tpad088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 05/26/2023] [Accepted: 07/04/2023] [Indexed: 07/11/2023]
Abstract
Plant hydraulic traits related to leaf drought tolerance, like the water potential at turgor loss point (TLP) and the water potential inducing 50% loss of hydraulic conductance (P50), are extremely useful to predict the potential impacts of drought on plants. While novel techniques have allowed the inclusion of TLP in studies targeting a large group of species, fast and reliable protocols to measure leaf P50 are still lacking. Recently, the optical method coupled with the gas injection (GI) technique has been proposed as a possibility to speed up the P50 estimation. Here, we present a comparison of leaf optical vulnerability curves (OVcs) measured in three woody species, namely Acer campestre (Ac), Ostrya carpinifolia (Oc) and Populus nigra (Pn), based on bench dehydration (BD) or GI of detached branches. For Pn, we also compared optical data with direct micro-computed tomography (micro-CT) imaging in both intact saplings and cut shoots subjected to BD. Based on the BD procedure, Ac, Oc and Pn had P50 values of -2.87, -2.47 and -2.11 MPa, respectively, while the GI procedure overestimated the leaf vulnerability (-2.68, -2.04 and -1.54 MPa for Ac, Oc and Pn, respectively). The overestimation was higher for Oc and Pn than for Ac, likely reflecting the species-specific vessel lengths. According to micro-CT observations performed on Pn, the leaf midrib showed none or very few embolized conduits at -1.2 MPa, consistent with the OVcs obtained with the BD procedure but at odds with that derived on the basis of GI. Overall, our data suggest that coupling the optical method with GI might not be a reliable technique to quantify leaf hydraulic vulnerability since it could be affected by the 'open-vessel' artifact. Accurate detection of xylem embolism in the leaf vein network should be based on BD, preferably of intact up-rooted plants.
Collapse
|
6
|
Optical method supported by machine learning for urinary tract infection detection and urosepsis risk assessment. JOURNAL OF BIOPHOTONICS 2023; 16:e202300095. [PMID: 37285226 DOI: 10.1002/jbio.202300095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Revised: 05/12/2023] [Accepted: 05/16/2023] [Indexed: 06/09/2023]
Abstract
The study presents an optical method supported by machine learning for discriminating urinary tract infections from an infection capable of causing urosepsis. The method comprises spectra of spectroscopy measurement of artificial urine samples with bacteria from solid cultures of clinical E. coli strains. To provide a reliable classification of results assistance of 27 algorithms was tested. We proved that is possible to obtain up to 97% accuracy of the measurement method with the use of use of machine learning. The method was validated on urine samples from 241 patients. The advantages of the proposed solution are the simplicity of the sensor, mobility, versatility, and low cost of the test.
Collapse
|
7
|
Advances in Portable Heavy Metal Ion Sensors. SENSORS (BASEL, SWITZERLAND) 2023; 23:4125. [PMID: 37112466 PMCID: PMC10143460 DOI: 10.3390/s23084125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/09/2023] [Revised: 04/16/2023] [Accepted: 04/18/2023] [Indexed: 06/19/2023]
Abstract
Heavy metal ions, one of the major pollutants in the environment, exhibit non-degradable and bio-chain accumulation characteristics, seriously damage the environment, and threaten human health. Traditional heavy metal ion detection methods often require complex and expensive instruments, professional operation, tedious sample preparation, high requirements for laboratory conditions, and operator professionalism, and they cannot be widely used in the field for real-time and rapid detection. Therefore, developing portable, highly sensitive, selective, and economical sensors is necessary for the detection of toxic metal ions in the field. This paper presents portable sensing based on optical and electrochemical methods for the in situ detection of trace heavy metal ions. Progress in research on portable sensor devices based on fluorescence, colorimetric, portable surface Raman enhancement, plasmon resonance, and various electrical parameter analysis principles is highlighted, and the characteristics of the detection limits, linear detection ranges, and stability of the various sensing methods are analyzed. Accordingly, this review provides a reference for the design of portable heavy metal ion sensing.
Collapse
|
8
|
Recent Advances in Detection for Breast-Cancer-Derived Exosomes. Molecules 2022; 27:molecules27196673. [PMID: 36235208 PMCID: PMC9571663 DOI: 10.3390/molecules27196673] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 10/03/2022] [Accepted: 10/04/2022] [Indexed: 11/28/2022] Open
Abstract
Breast cancer is the most common malignant tumor in women, its incidence is secret, and more than half of the patients are diagnosed in the middle and advanced stages, so it is necessary to develop simple and efficient detection methods for breast cancer diagnosis to improve the survival rate and quality of life of breast cancer patients. Exosomes are extracellular vesicles secreted by all kinds of living cells, and play an important role in the occurrence and development of breast cancer and the formation of the tumor microenvironment. Exosomes, as biomarkers, are an important part of breast cancer fluid biopsy and have become ideal targets for the early diagnosis, curative effect evaluation, and clinical treatment of breast cancer. In this paper, several traditional exosome detection methods, including differential centrifugation and immunoaffinity capture, were summarized, focusing on the latest research progress in breast cancer exosome detection. It was summarized from the aspects of optics, electrochemistry, electrochemiluminescence and other aspects. This review is expected to provide valuable guidance for exosome detection of clinical breast cancer and the establishment of more reliable, efficient, simple and innovative methods for exosome detection of breast cancer in the future.
Collapse
|
9
|
Hyperspectral imaging for quantitative assessment of hepatic steatosis in human liver allografts. Clin Transplant 2022; 36:e14736. [PMID: 35622345 DOI: 10.1111/ctr.14736] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Revised: 04/25/2022] [Accepted: 05/01/2022] [Indexed: 11/24/2022]
Abstract
INTRODUCTION In liver transplantation (LT), steatosis is commonly judged to be a risk factor for graft dysfunction, and quantitative assessment of hepatic steatosis remains crucial. Liver biopsy as the gold standard for evaluation of hepatic steatosis has certain drawbacks, i.e. invasiveness, and intra- and inter-observer variability. A non-invasive, quantitative modality could replace liver biopsy and eliminate these disadvantages, but has not yet been evaluated in human LT. METHODS We performed a pilot study to evaluate the feasibility and accuracy of hyperspectral imaging (HSI) in the assessment of hepatic steatosis of human liver allografts for transplantation. Thirteen deceased donor liver allografts were included in the study. The degree of steatosis was assessed by means of conventional liver biopsy as well as HSI, performed at the end of backtable preparation, during normothermic machine perfusion (NMP), and after reperfusion in the recipient. RESULTS Organ donors were 51 [30-83] years old, and 61.5% were male. Donor body mass index was 24.2 [16.5-38.0] kg/m2. The tissue lipid index (TLI) generated by HSI at the end of back-table preparation correlated significantly with the histopathologically assessed degree of overall hepatic steatosis (R2 = 0.9085, p<0.0001); this was based on a correlation of TLI and microvesicular steatosis (R2 = 0.8120; p<0.0001). There is also a linear relationship between the histopathologically assessed degree of overall steatosis and TLI during NMP (R2 = 0.5646; p = 0.0031) as well as TLI after reperfusion (R2 = 0.6562; p = 0.0008). CONCLUSION HSI may safely be applied for accurate assessment of hepatic steatosis in human liver grafts. Certainly, TLI needs further assessment and validation in larger sample sizes. This article is protected by copyright. All rights reserved.
Collapse
|
10
|
Contactless Measurement of Integrity of Silicone Coating on Self-Expandable Esophageal Nitinol Stents. ACTA MEDICA (HRADEC KRALOVE) 2022; 65:18-24. [PMID: 35793504 DOI: 10.14712/18059694.2022.11] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
OBJECTIVES A stent is a mesh tube inserted into a natural passage in the body to prevent disease induction. Self-expandable esophageal nitinol stents such as SX-ELLA Stent Esophageal HV (HV Stent Plus) can be indicated for palliation of malignant esophageal strictures, for the treatment of benign esophageal strictures that are refractory to standard therapy and for the treatment of esophago-respiratory fistulas. A silicone-stent coating is used for tumor in-growth prevention and esophago-respiratory fistula occlusion. The thickness of the stent and the overall integrity of the silicone coating of all wires indicate the overall mechanical properties of the esophageal stent and the resistance to external adverse events such as corrosion and mechanical and chemical resistance. METHODS The polymer multicomponent epoxy resin - a mixture of Epon and Durcupan - was used as a method for robust sample stabilization. A cutting system using a thin water beam with a powder (Blue Line) was chosen as the best variant to obtain 6 samples for both-sided measurement (10 measuring sides). The optical microscopic reflective light method was used to examine wire crossing points in the sections. Fifty values were measured on either sample side for the internal, external and mesh thickness of the silicone stent layer. The wire crossing points were selected so that the silicone layer structure could be clearly seen, and the wires approached each other most closely. Only approximately 4 to 8 crossing points in each section could be measured when applying this approach. The resolution of the microscope and calibration (based on the camera used) was 0.677 μm/pixel. RESULTS Additional data could be obtained on 8 planes. Two boundary samples were destroyed by the cutting process. Whole coating of the stent was around all mesh wires, especially in areas with higher mechanical stress (wire crossing). The minimum detectable and admissible value determined for all 3 measuring areas (internal, external, mesh) on the wire crossings was 6.77 μm, i.e., 10 pixels, based on the microscope resolution and manufacturer's methodology. The results were characterized by p < 0.001 for all 3 parameters. We tested opposite samples in each section to verify the section quality and data consistency. For the 4 areas, the data were significantly different, but the thickness differences were only on the order of units percent, so the measurements were not appreciably affected. We assume that the material cutting loss, making up 1-2 mm, contributed to the differences in the sections. CONCLUSION We examined the overall integrity of the silicone coating of the esophageal stent. The method of HV stent anchoring in a polymeric bath followed by cutting with a waterjet and sample measurement under an optical microscope proved to be very simple and reliable. Sufficient thicknesses of the silicone layer on the wire cross sections were verified. The coated silicone layer thickness appeared to be significantly different along the stent from the proximal part to the distant part, presumably due to the manufacturing technology.
Collapse
|
11
|
Application of magnetic bead method in detecting coagulation function. ANNALS OF PALLIATIVE MEDICINE 2021; 10:10607-10615. [PMID: 34763508 DOI: 10.21037/apm-21-2713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Accepted: 10/22/2021] [Indexed: 11/06/2022]
Abstract
BACKGROUND Blood samples indicative of jaundice, lipemia, hemolysis, and others are often encountered in the laboratory, and such features impact greatly on the detection of coagulation items. To understand the anti-interference ability of the magnetic bead method automatic coagulation instrument and the optical method automatic coagulation instrument against jaundice, lipemia, and hemolysis, anti-interference experiments of prolonged prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), and fibrinogen (FIB) were conducted using ExC810 (magnetic bead method) and CS5100 (optical method). METHODS Interference samples were prepared with bilirubin, hemoglobin, and lipids, while control samples were prepared with NaOH and distilled water. The samples contained different values of PT, APTT, TT, and FIB and were detected by magnetic bead method and optical method, respectively. The relative deviation was calculated according to the formula. RESULTS In the anti-interference experiment of PT, APTT, TT, and FIB (jaundice, lipemia, hemolysis), the deviation between the test results and the control results with the addition of interfering substances tested by ExC810 was lower overall than that of CS5100. However, after the addition of interfering substances, most of the items were not detected by CS5100 in the anti-lipidemia experiment. CONCLUSIONS When testing coagulation function, the magnetic bead method has better anti-interference recognition of jaundice, lipemia, and hemolysis than the optical method, and its anti-lipemic interference has a particularly obvious advantage.
Collapse
|
12
|
No gas source, no problem: Proximity to pre-existing embolism and segmentation affect embolism spreading in angiosperm xylem by gas diffusion. PLANT, CELL & ENVIRONMENT 2021; 44:1329-1345. [PMID: 33529382 DOI: 10.22541/au.159674582.24283294] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Revised: 01/16/2021] [Accepted: 01/17/2021] [Indexed: 05/29/2023]
Abstract
Embolism spreading in dehydrating angiosperm xylem is driven by gas movement between embolized and sap-filled conduits. Here we examine how the proximity to pre-existing embolism and hydraulic segmentation affect embolism propagation. Based on the optical method, we compare xylem embolism resistance between detached leaves and leaves attached to branches, and between intact leaves and leaves with cut minor veins, for six species. Embolism resistance of detached leaves was significantly lower than that of leaves attached to stems, except for two species, with all vessels ending in their petioles. Cutting of minor veins showed limited embolism spreading in minor veins near the cuts prior to major veins. Moreover, despite strong agreement in the overall embolism resistance of detached leaves between the optical and pneumatic method, minor differences were observed during early stages of embolism formation. We conclude that embolism resistance may represent a relative trait due to an open-xylem artefact, with embolism spreading possibly affected by the proximity and connectivity to pre-existing embolism as a gas source, while hydraulic segmentation prevents such artefact. Since embolism formation may not rely on a certain pressure difference threshold between functional and embolized conduits, we speculate that embolism is facilitated by pressure-driven gas diffusion across pit membranes.
Collapse
|
13
|
No gas source, no problem: Proximity to pre-existing embolism and segmentation affect embolism spreading in angiosperm xylem by gas diffusion. PLANT, CELL & ENVIRONMENT 2021; 44:1329-1345. [PMID: 33529382 DOI: 10.1111/pce.14016] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Revised: 01/16/2021] [Accepted: 01/17/2021] [Indexed: 05/12/2023]
Abstract
Embolism spreading in dehydrating angiosperm xylem is driven by gas movement between embolized and sap-filled conduits. Here we examine how the proximity to pre-existing embolism and hydraulic segmentation affect embolism propagation. Based on the optical method, we compare xylem embolism resistance between detached leaves and leaves attached to branches, and between intact leaves and leaves with cut minor veins, for six species. Embolism resistance of detached leaves was significantly lower than that of leaves attached to stems, except for two species, with all vessels ending in their petioles. Cutting of minor veins showed limited embolism spreading in minor veins near the cuts prior to major veins. Moreover, despite strong agreement in the overall embolism resistance of detached leaves between the optical and pneumatic method, minor differences were observed during early stages of embolism formation. We conclude that embolism resistance may represent a relative trait due to an open-xylem artefact, with embolism spreading possibly affected by the proximity and connectivity to pre-existing embolism as a gas source, while hydraulic segmentation prevents such artefact. Since embolism formation may not rely on a certain pressure difference threshold between functional and embolized conduits, we speculate that embolism is facilitated by pressure-driven gas diffusion across pit membranes.
Collapse
|
14
|
Abstract
Exosomes, small vesicles with the diameters of 40-160 nm, play an important role in intercellular transport and communication. Exosomes are rich in many kinds of biomolecules, and differential expression of exosomal contents directly reflects the state of the original cells. Therefore, the tumor exosomes are appearing as promising biomarkers in liquid biopsy, and highly sensitive and specific detection of tumor exosomes may provide the information for the early diagnosis, real-time monitoring and treatment of the tumors. In this review, we summarized the recent advances in the detection of tumor exosomes, mainly focusing on the use of different analytical techniques, such as optical and electrochemical methods as well as that combination with newly-emerging microfluidic techniques, thereby providing valuable information for the application in the clinical diagnosis and management of the tumors.
Collapse
|
15
|
A Leaf Selfie: Using a Smartphone to Quantify Leaf Vulnerability to Hydraulic Dysfunction. PLANTS (BASEL, SWITZERLAND) 2020; 9:E234. [PMID: 32054113 PMCID: PMC7076359 DOI: 10.3390/plants9020234] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Revised: 01/21/2020] [Accepted: 02/05/2020] [Indexed: 05/28/2023]
Abstract
Accurate predictions of species distribution under current and future climate conditions require modeling efforts based on clear mechanistic relationships between climate variables and plant physiological functions. Vulnerability of leaves to xylem embolism is a key mechanistic trait that might be included in these modeling efforts. Here, we propose a simple set-up to measure leaf vulnerability to embolism on the basis of the optical method using a smartphone, a light source, and a notebook. Our data show that this proposed set-up can adequately quantify the vulnerability to xylem embolism of leaf major veins in Populus nigra and Ostrya carpinifolia, producing values consistent with those obtained in temperate tree species with other methods, allowing virtually any laboratory to quantify species-specific drought tolerance on the basis of a sound mechanistic trait.
Collapse
|
16
|
Contactless Visualization of Latent Fingerprints on Nonporous Curved Surfaces of Circular Cross Section-A Statistical Evaluation on the Materials as Plane Mirror. J Forensic Sci 2017; 63:1092-1098. [PMID: 29178492 DOI: 10.1111/1556-4029.13702] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2017] [Revised: 09/13/2017] [Accepted: 11/01/2017] [Indexed: 11/30/2022]
Abstract
A new contactless technique for latent fingerprint visualization on nonporous curved surfaces of circular cross section was introduced by Low et al. (1). The technique utilizes a plane mirror to convey the light rays toward the inspected surfaces for latent fingerprint visualization. This research activity came up as an extension of the previous study which utilized an aluminum plate as the plane mirror to illuminate the inspected surfaces. Dulling spray was used to increase the diffuse component of the reflective aluminum plate. However, the amount of dulling spray will affect the uniformity of the illumination on the inspected curved surfaces. In this study, a study on the new materials for the plane mirror was carried out. Coated aluminum, opal, and ground glass diffusers were selected as the new materials. The performance of the new materials was compared to the aluminum based on the quality of the captured images on various nonporous cylindrical surfaces. A statistical approach known as randomized complete block design was used to design the experiment. The quality of the captured images was obtained using Spectral Image Validation and Verification. Two-way analysis of variance and Fisher's least significant difference test were used to analyze the quality of the images. From the results of the statistical analysis, coated aluminum has the best performance compared to aluminum, opal, and ground glass diffusers.
Collapse
|
17
|
Contactless Visualization of Latent Fingerprints on Nonporous Curved Surfaces of Circular Cross Section. J Forensic Sci 2016; 61:1093-9. [PMID: 27364293 DOI: 10.1111/1556-4029.13063] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2015] [Revised: 07/03/2015] [Accepted: 09/04/2015] [Indexed: 11/29/2022]
Abstract
Nondestructive techniques for gathering evidence are important in the field of forensics. Due to the geometry of the substrates, nondestructive visualization of fingermarks on curved surfaces remains challenging. A novel contactless technique was developed for visualizing and recording fingermark patterns on nonporous curved surfaces of circular cross section. The technique utilizes a plane mirror to transmit rays from a light source to illuminate the area of interest for fingermark visualization. The fingermark acquisition system consists of a digital single-lens reflex (SLR) camera, a plane mirror, and a white light source. Mathematical equations are used to calculate the mirror size. Experiments were performed on various curved surfaces to determine the feasibility and effectiveness of the technique. Spectral Image Validation and Verification (SIVV) was used to analyze the captured images. The results of this study indicate that the technique described here is able to reveal fingermark patterns on curved surfaces of circular cross section.
Collapse
|
18
|
Abstract
This article describes a performance assessment of three optical methods, a Magee Scientific OT21 Transmissometer, a Hach-Lange Microcolor II difference gloss meter, and a combination of an office scanner with Adobe Photoshop software. The optical methods measure filter staining as a proxy for elemental carbon in diesel exhaust particulate (DEP) exposure assessment and the suitability of each as a replacement for the existing Bosch meter optical method. Filters loaded with DEP were produced from air in a non-coal mine and the exhaust gases from a mobile crane. These were measured with each apparatus and then by combustion to obtain a reference elemental carbon value. The results from each apparatus were then plotted against both the Bosch number and reference elemental carbon values. The equations of the best fit lines for these plots were derived, and these gave functions for elemental carbon and Bosch number from the output of each new optical method. For each optical method, the range of DEP loadings which can be measured has been determined, and conversion equations for elemental carbon and Bosch number have been obtained. All three optical methods studied will effectively quantify blackness as a measure of elemental carbon. Of these the Magee Scientific OT21 transmissometer has the best performance. The Microcolor II and scanner/photoshop methods will in addition allow conversion to Bosch number which may be useful if historical Bosch data are available and functions for this are described. The scanner/photoshop method demonstrates a technique to obtain measurements of DEP exposure without the need to purchase specialized instrumentation.
Collapse
|