1
|
Comparing a 19-gauge fine-needle biopsy needle with a 22-gauge fine-needle biopsy needle for EUS-guided liver biopsy sampling: a prospective randomized study. Gastrointest Endosc 2024; 99:931-937. [PMID: 38141686 DOI: 10.1016/j.gie.2023.12.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/05/2023] [Revised: 10/27/2023] [Accepted: 12/17/2023] [Indexed: 12/25/2023]
Abstract
BACKGROUND AND AIMS EUS-guided liver biopsy (EUS-LB) sampling is being increasingly used. We performed a prospective randomized trial to compare specimen adequacy of a 19-gauge fine-needle biopsy (FNB) needle with a 22-gauge FNB Franseen tip needle for EUS-LB sampling. METHODS Forty-two consecutive patients referred for EUS-LB sampling were prospectively randomized to a 19-gauge or 22-gauge FNB needle. When the specimen with the 22-gauge needle was macroscopically inadequate, an additional pass with the 19-gauge needle was done. Bilobar EUS-LB sampling was performed with heparinized wet suction using 1 pass and 3 actuations per lobe. Descriptive statistics were computed for all variables. RESULTS Biopsy sampling was performed for abnormal liver enzymes in 95.5% of patients (57% women; average age, 51 years). Five patients undergoing sampling with the 22-gauge FNB needle had macroscopically inadequate specimens and required additional biopsy sampling with the 19-gauge FNB needle. Mean preprocessing length of the longest tissue core was 21.5 ± 6.3 mm with a 19-gauge FNB needle compared with 9.4 ± 5.5 mm with the 22-gauge FNB needle (P < .001). Postprocessing specimens were significantly longer with 19-gauge than with 22-gauge FNB needles (17.4 mm vs 6.8, P < .001). There were no adverse events, and postprocedure pain and discomfort was similar in both groups (14% for 19-gauge vs 10% for 22-gauge, P = .99). CONCLUSIONS Liver core biopsy sampling using the 19-gauge FNB needle is superior to the 22-gauge FNB needle in terms of length of longest core and aggregate specimen length. Considerably more fragmentation of the 22-gauge cores occurs during tissue processing. No increased postprocedure pain or AEs were found with the 19-gauge needle. A 19-gauge FNB needle is preferred to the 22-gauge FNB needle for EUS-LB. (Clinical trial registration number: NCT04806607.).
Collapse
|
2
|
Current perspectives on the diversification of endoscopic ultrasound-guided fine-needle aspiration and biopsy. J Med Ultrason (2001) 2024; 51:235-243. [PMID: 38108995 DOI: 10.1007/s10396-023-01393-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Accepted: 10/23/2023] [Indexed: 12/19/2023]
Abstract
Endoscopic ultrasound-guided tissue acquisition (EUS-TA) has undergone significant advancements since it was first reported in 1992. Initially focused on the pancreas, EUS-guided fine-needle aspiration (FNA) has now been extended to encompass all organs proximal to the gastrointestinal system. Recently, a novel fine-needle biopsy (FNB) needle with an end-cut tip was developed, allowing for the collection of specimens suitable for histological assessment, a feat hard to achieve with traditional needles. The FNB needle holds promise for applications in immunohistochemistry staining and genetics evaluation, and it has the potential to yield specimens of comparable quality to core needle biopsy during percutaneous puncture, especially for lesions beyond the pancreas, such as lymph nodes. This review focuses on the efficacy of EUS-FNA/FNB for extended target regions, specifically lymph nodes, spleen, adrenal gland, and ascites. The indications for EUS-FNA have greatly expanded beyond the pancreas over the years, and future improvements and innovations in puncture needles will allow for the collection of higher-quality specimens, which is expected to play a significant part in personalized cancer treatment.
Collapse
|
3
|
Cutting edge of endoscopic ultrasound-guided fine-needle aspiration for solid pancreatic lesions. J Med Ultrason (2001) 2024; 51:209-217. [PMID: 37914883 PMCID: PMC11098899 DOI: 10.1007/s10396-023-01375-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Accepted: 08/31/2023] [Indexed: 11/03/2023]
Abstract
This article provides an extensive review of the advancements and future perspectives related to endoscopic ultrasound-guided tissue acquisition (EUS-TA) for the diagnosis of solid pancreatic lesions (SPLs). EUS-TA, including fine-needle aspiration (EUS-FNA) and fine-needle biopsy (EUS-FNB), has revolutionized the collection of specimens from intra-abdominal organs, including the pancreas. Improvements in the design of needles, collection methods, and specimen processing techniques have improved the diagnostic performance. This review highlights the latest findings regarding needle evolution, actuation number, sampling methods, specimen evaluation techniques, application of artificial intelligence (AI) for diagnostic purposes, and use of comprehensive genomic profiling (CGP). It acknowledges the rising use of Franseen and fork-tip needles for EUS-FNB and emphasizes that the optimal number of actuations requires further study. Methods such as the door-knocking and fanning techniques have shown promise for increasing diagnostic performance. Macroscopic on-site evaluation (MOSE) is presented as a practical rapid specimen evaluation method, and the integration of AI is identified as a potentially impactful development. The study also underscores the importance of optimal sampling for CGP, which can enhance the precision of cancer treatment. Ongoing research and technological innovations will further improve the accuracy and efficacy of EUS-TA.
Collapse
|
4
|
Effectiveness of Menghini-Type Needles for Endoscopic Ultrasound-Guided Fine-Needle Aspiration of Pancreatic Masses. Dig Dis Sci 2021; 66:3171-3178. [PMID: 33078322 DOI: 10.1007/s10620-020-06628-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/04/2020] [Accepted: 09/16/2020] [Indexed: 01/03/2023]
Abstract
BACKGROUND Cutting needles are thought to be effective as biopsy needles. A few types of cutting needles are available for endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA), and the Menghini-type needle is an end-type cutting needle. AIMS A prospective randomized controlled trial was conducted to compare the results of EUS-FNA using a Menghini-type needle (needle M) versus a conventional needle (needle S). METHODS The main eligibility criteria were as follows: patients with a pancreatic mass referred for EUS-FNA, ≥ 20 years old, and a performance status < 4. The primary outcome was the sample quality. The secondary outcomes were factors associated with the sample quality, diagnostic accuracy, and adverse events. RESULTS A total of 97 patients were enrolled in this study. The sample quality for total puncture with needle M (92.8%) was significantly higher than that with needle S (81.4%) (p = 0.0305). The tumor size (p = 0.033) and type of needle (p = 0.031) were significant factors associated with adequate tissue collection in univariate and multivariate analyses (odds ratio [OR] 2.71; 95% confidence interval [CI] 1.12-6.54; p = 0.027 for tumor size, and OR 2.93; 95% CI 1.23-8.21; p = 0.0153 for type of needle). The diagnostic accuracy of each needle was 88.7% (86/97) with needle M and 73.2% (71/97) with needle S. Adverse events occurred in 2 of the 97 patients (0.02%). CONCLUSION A Menghini-type needle was able to obtain core tissue for histology more effectively than a conventional aspiration needle. TRIAL REGISTRATION NUMBERS UMIN registration number of 000020668.
Collapse
|
5
|
Calponin and MUC6 complement inhibin as diagnostic immunomarkers of serous cystadenoma in endoscopic ultrasound-guided aspiration/biopsy specimens. Histopathology 2021; 79:252-259. [PMID: 33657658 DOI: 10.1111/his.14362] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Revised: 02/18/2021] [Accepted: 03/02/2021] [Indexed: 12/12/2022]
Abstract
AIMS Because serous cystadenoma (SCA) does not usually require excision, it is critical to distinguish it from differential diagnoses which do, especially neuroendocrine tumour (NET). The gold standard for diagnosing SCA is assessment of endoscopic ultrasound-guided fine needle aspiration/biopsy (EUS-FNAB) material. Inhibin immunohistochemistry aids this assessment, but such positivity is not absolutely sensitive or specific to SCA. The following is the largest known study of SCA EUS-FNAB specimens and the first to compare four potential SCA immunomarkers between themselves and inhibin, compared against NET. METHODS AND RESULTS Immunohistochemistry for calponin, mucin 6 (MUC6), glucose transporter 1 (GLUT1) and vascular endothelial growth factor A (VEGFA) was performed on 30 EUS-FNAB and three resection specimens of SCA and 32 EUS-FNAB specimens of NET. GLUT1 and VEGFA were suboptimal as diagnostic immunomarkers of SCA, being expressed by 10 and 44% of NETs, respectively. Further, their expression by cellular constituents of blood which often contaminate EUS-FNAB specimens hampered identification of neoplastic cells, especially in hypocellular samples. While 19% of NETs showed nuclear MUC6 positivity, cytoplasmic expression of the protein showed 100% specificity and sensitivity as an SCA marker. However, assessing MUC6 in EUS-FNAB specimens must also consider the protein's focal expression in physiological pancreatic, gastric or duodenal tissues, which can contaminate these specimens. Calponin was less sensitive (71% versus 100%) but more specific (100% versus 91%) than inhibin, although easier to assess in EUS-FNAB specimens than MUC6. CONCLUSIONS Of the four potential immunomarkers of SCA suggested by the existing literature, calponin and MUC6 are useful complementary studies to inhibin for application to EUS-FNAB specimens.
Collapse
|
6
|
Randomized controlled trial comparing a conventional needle and a novel needle for endoscopic ultrasound (EUS)-guided histology of peripancreatic masses. Medicine (Baltimore) 2021; 100:e25106. [PMID: 33725907 PMCID: PMC7969324 DOI: 10.1097/md.0000000000025106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/26/2020] [Accepted: 02/18/2021] [Indexed: 01/05/2023] Open
Abstract
INTRODUCTION Cytological study of samples obtained by Endoscopic ultrasound (EUS)-guided fine-needle aspiration (EUS-FNA) allows for recognition of clear signs of malignant transformation. However, certain neoplasms can be difficult to diagnose without histological analysis. Recently, a novel EUS-guided fine needle biopsy (EUS-FNB) needle was developed to increase tissue acquisition. This study set out to investigate the usefulness of this novel EUS-FNB needle (NEFN) in terms of obtaining a proper histology compared with a conventional EUS-FNA needle (CEFN). METHODS This investigation was a prospective, single-blind, randomized study in a single academic hospital. Primary outcome was the acquisition rate of an appropriate and sufficient specimen for histologic assessment. Secondary outcomes were diagnostic yield of peripancreatic masses using a CEFN and a NEFN. Furthermore, we assessed the feasibility of determining K-ras mutation status according to needle type. RESULTS The study enrolled 56 consecutive patients. Technical success rates were 96.6% (28/29) for the CEFN and 100% (27/27) for the NEFN (P = 1.000). No complications occurred during or after the procedure in either needle group. An adequate sample for cytologic diagnosis was obtained in 89.7% (26/29) of patients in the CEFN group vs 96.3% (26/27) of patients in the NEFN group (P = .612). For histologic diagnosis, a sample with a biopsy adequacy score of 2 or more was obtained in 41.4% (12/29) of CEFN-acquired samples vs 88.9% (24/27) of NEFN-acquired samples (P < .001). K-ras mutation analysis using histologic specimens was possible in 13 (44.8%) CEFN-acquired samples and 25 (92.6%) of NEFN-acquired samples. This difference was significant (P < .001). CONCLUSIONS The present study suggests that the NEFN is an effective and reliable alternative compared to a CEFN in terms of tissue acquisition rate and quality of histologic sampling.
Collapse
|
7
|
Surface Texturing Design to Enhance Echogenicity of Biopsy Needles During Endoscopic Ultrasound Imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2020; 46:2453-2463. [PMID: 32546410 DOI: 10.1016/j.ultrasmedbio.2020.04.034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/15/2019] [Revised: 04/28/2020] [Accepted: 04/29/2020] [Indexed: 06/11/2023]
Abstract
The ultrasonic visibility of a biopsy needle tip is of critical importance for the success and safety of endoscopic ultrasound (EUS)-guided fine needle aspiration (FNA) procedures. The aim of this study was to design a surface topology, in silico, which enhances the ultrasound visibility of a needle by controlling and optimising the direction of the reflections. Topographic enhancements to needle surface redirect scattered waves back to the transducer to enhance needle visibility, or "echogenicity." Echogenicity enhancement is demonstrated across insonification angles of 30°-90° on full-length scale of biopsy needles used in practice. By applying a textured surface across the full length of the needle surface, the signal being returned to the transducer can be tripled from that of a constant periodic dimple echogenic surface and seven times that of an untextured flat surface. Our first principles model provides a quantitative insight to echogenicity and its enhancement. The model allows in silico design of needles for USG-FNA and biopsy with enhanced echogenicity and consequent improvement in visibility, including but not limited to needle tip area.
Collapse
|
8
|
Core needle biopsy with endobronchial ultrasonography: single center experience with 100 cases. J Am Soc Cytopathol 2020; 9:249-253. [PMID: 32451285 DOI: 10.1016/j.jasc.2020.04.009] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2020] [Revised: 04/14/2020] [Accepted: 04/16/2020] [Indexed: 12/25/2022]
Abstract
INTRODUCTION Adequate sampling by endobronchial ultrasound (EBUS)-transbronchial needle aspiration to meet the demands of precision medicine or histologic evaluation is challenging. There is increasing demand for core biopsy specimens with advances in therapy. Franseen enodoscopic ultrasound needles have shown promising results in gastroenterology application for obtaining core biopsies and same design has recently been extended for pulmonary use. We evaluated Franseen needles with EBUS to assess its utility, safety and ability to provide core biopsy specimens. MATERIALS AND METHODS Retrospective analysis of our database at the University of Utah of patients undergoing EBUS with a Franseen needle was performed to ascertain the performance characteristics of this needle in the first 100 patients after its implementation. Medical records were also reviewed to identify any immediate procedure-related complications. RESULTS One hundred seventy locations were sampled in 100 patients. A total of 152 lymph nodes and 18 masses were sampled. Core biopsies, as per pathology report, were seen in 87% of patients. A clinically concordant pathological diagnosis was established in 97% of patients. Diagnostic yield for granulomatous lymphadenopathy was 95.6% (22 of 23). No patient-related adverse events were noted. CONCLUSION The Franseen needle evaluated in this study can safely procure core tissue samples during EBUS bronchoscopy that are adequate for histopathological diagnosis in benign and malignant lesions. Its ability to provide adequate tissue in patients with granulomatous inflammation is encouraging.
Collapse
|
9
|
Comparison of a 22-gauge Franseen-tip needle with a 20-gauge forward-bevel needle for the diagnosis of type 1 autoimmune pancreatitis: a prospective, randomized, controlled, multicenter study (COMPAS study). Gastrointest Endosc 2020; 91:373-381.e2. [PMID: 31654634 DOI: 10.1016/j.gie.2019.10.012] [Citation(s) in RCA: 59] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2019] [Accepted: 10/03/2019] [Indexed: 12/11/2022]
Abstract
BACKGROUND AND AIMS Histologic diagnosis of autoimmune pancreatitis (AIP) using EUS-guided FNA (EUS-FNA) is difficult. To address this issue, new fine-needle biopsy (FNB) needles were recently developed. Here, we prospectively evaluated 2 newly designed EUS-FNB needles for histologic evaluation in patients with type 1 AIP. METHODS This was a prospective, randomized, multicenter trial comparing biopsy specimens obtained with a 22-gauge Franseen needle or a 20-gauge forward-bevel needle in patients with suspected type 1 AIP. AIP was diagnosed according to international consensus diagnostic criteria. The primary endpoint was the sensitivity of EUS-FNB needles, and secondary endpoints were the amount of specimen obtained, histology of the pancreas based on evaluation of lymphoplasmacytic sclerosing pancreatitis (LPSP), and contribution of histologic findings to the diagnosis of AIP. RESULTS One hundred ten patients were randomly assigned to the Franseen group (22-gauge Franseen needle) or the forward-bevel group (20-gauge forward-bevel needle). EUS-FNB sampling was successful in all patients. Nine patients were excluded because of diagnoses other than AIP. Compared with the forward-bevel needle, the Franseen needle obtained a significantly greater number of high-power fields. Of 101 patients, 39 patients (78%) in the Franseen group and 23 patients (45%) in the Forward-bevel group were diagnosed with level 1 or 2 LPSP (P = .001). Thirty-six patients could not be diagnosed with type 1 AIP without EUS-FNB specimen results. CONCLUSIONS The 22-gauge Franseen needle should be routinely used for histologic diagnosis of type 1 AIP. (Clinical trial registration number: UMIN 000027668.).
Collapse
|
10
|
Association between macroscopically visible tissue samples and diagnostic accuracy of EUS-guided through-the-needle microforceps biopsy sampling of pancreatic cystic lesions. Gastrointest Endosc 2019; 90:933-943. [PMID: 31100310 DOI: 10.1016/j.gie.2019.05.009] [Citation(s) in RCA: 46] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Accepted: 05/06/2019] [Indexed: 12/11/2022]
Abstract
BACKGROUND AND AIMS EUS-guided through-the-needle biopsy (TTNB) sampling has been reported to improve diagnostic yield compared with cytology for the evaluation of pancreatic cystic lesions (PCLs). The number of macroscopically visible tissue samples needed to reach an adequate diagnosis is still unknown. METHODS This is a retrospective, single-center study on consecutive patients with PCLs with risk features (cyst >3 cm, thickened wall, cyst growth during follow-up, and mural nodules) who underwent TTNB sampling. The capability of differentiating mucinous versus nonmucinous cysts, ability to obtain a cyst-lining epithelium, definition of the grade of dysplasia, and specific diagnosis of cyst histotype were evaluated for 1, 2, or 3 TTNB macroscopically visible specimens. RESULTS Sixty-one patients were evaluated. A 100% histologic adequacy was reached by 2 samples (P = .05 versus 1). Compared with cytology, 1 TTNB specimen improved the possibility of defining cyst histotype (P < .0001), whereas 2 specimens increased all 4 diagnostic categories (P < .003). Two specimens also increased diagnostic yield compared with 1 sample (P < .085). The collection of a third sample did not improve the value of any diagnostic categories. A specific diagnosis was reached in 74% of patients with 2 histologic samples. The diagnostic reliability of TTNB sampling compared with surgical histology was 90%, with a 22.9% rate of adverse events. CONCLUSIONS Two TTNB macroscopically visible specimens reached 100% histologic adequacy and a specific diagnosis in 74% of patients. The collection of a third specimen did not add any additional information and should be avoided to possibly decrease the risk of adverse events.
Collapse
|
11
|
Residual Metal Contaminants in Endoscopic Ultrasound-Guided Fine-Needle Aspiration. Acta Cytol 2019; 64:394-396. [PMID: 31645039 DOI: 10.1159/000503915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2019] [Accepted: 10/06/2019] [Indexed: 11/19/2022]
|
12
|
Genetic testing vs microforceps biopsy in pancreatic cysts: Systematic review and meta-analysis. World J Gastroenterol 2019; 25:3450-3467. [PMID: 31341368 PMCID: PMC6639554 DOI: 10.3748/wjg.v25.i26.3450] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2019] [Revised: 04/17/2019] [Accepted: 05/18/2019] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Carcinoembryonic antigen (CEA) and cytology in pancreatic cystic fluid are suboptimal for evaluation of pancreatic cystic neoplasms. Genetic testing and microforceps biopsy are promising tools for pre-operative diagnostic improvement but comparative performance of both methods is unknown.
AIM To compare the accuracy of genetic testing and microforceps biopsy in pancreatic cysts referred for surgery.
METHODS We performed a literature search in Medline, Scopus, and Web of Science for studies evaluating genetic testing of cystic fluid and microforceps biopsy of pancreatic cysts, with endoscopic ultrasound with fine-needle aspiration (EUS-FNA) prior to surgery and surgical pathology as reference standard for diagnosis. We evaluated the diagnostic accuracy for: 1- benign cysts; 2- mucinous low-risk cysts; 3- high-risk cysts, and the diagnostic yield and rate of correctly identified cysts with microforceps biopsy and molecular analysis. We also assessed publication bias, heterogeneity, and study quality.
RESULTS Eight studies, including 1206 patients, of which 203 (17%) referred for surgery who met the inclusion criteria were analyzed in the systematic review, and seven studies were included in the meta-analysis. Genetic testing and microforceps biopsies were identical for diagnosis of benign cysts. Molecular analysis was superior for diagnosis of both low and high-risk mucinous cysts, with sensitivities of 0.89 (95%CI: 0.79-0.95) and 0.57 (95%CI: 0.42-0.71), specificities of 0.88 (95%CI: 0.75-0.95) and 0.88 (95%CI: 0.80-0.93) and AUC of 0.9555 and 0.92, respectively. The diagnostic yield was higher in microforceps biopsies than in genetic analysis (0.73 vs 0.54, respectively) but the rates of correctly identified cysts were identical (0.73 with 95%CI: 0.62-0.82 vs 0.71 with 95%CI: 0.49-0.86, respectively).
CONCLUSION Genetic testing and microforceps biopsies are useful second tests, with identical results in benign pancreatic cysts. Genetic analysis performs better for low- and high-risk cysts but has lower diagnostic yield.
Collapse
|
13
|
A multicenter randomized trial comparing a 25-gauge EUS fine-needle aspiration device with a 20-gauge EUS fine-needle biopsy device. Gastrointest Endosc 2019; 89:329-339. [PMID: 30367877 DOI: 10.1016/j.gie.2018.10.026] [Citation(s) in RCA: 75] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2018] [Accepted: 10/11/2018] [Indexed: 12/11/2022]
Abstract
BACKGROUND AND AIMS Several studies have compared EUS-guided FNA with fine-needle biopsy (FNB), but none have proven superiority. We performed a multicenter randomized controlled trial to compare the performance of a commonly used 25-gauge FNA needle with a newly designed 20-gauge FNB needle. METHODS Consecutive patients with a solid lesion were randomized in this international multicenter study between a 25-gauge FNA (EchoTip Ultra) or a 20-gauge FNB needle (ProCore). The primary endpoint was diagnostic accuracy for malignancy and the Bethesda classification (non-diagnostic, benign, atypical, malignant). Technical success, safety, and sample quality were also assessed. Multivariable and supplementary analyses were performed to adjust for confounders. RESULTS A total of 608 patients were allocated to FNA (n = 306) or FNB (n = 302); 312 pancreatic lesions (51%), 147 lymph nodes (24%), and 149 other lesions (25%). Technical success rate was 100% for the 25-gauge FNA and 99% for the 20-gauge FNB needle (P = .043), with no differences in adverse events. The 20-gauge FNB needle outperformed 25-gauge FNA in terms of histologic yield (77% vs 44%, P < .001), accuracy for malignancy (87% vs 78%, P = .002) and Bethesda classification (82% vs 72%, P = .002). This was robust when corrected for indication, lesion size, number of passes, and presence of an on-site pathologist (odds ratio, 3.53; 95% confidence interval, 1.55-8.56; P = .004), and did not differ among centers (P = .836). CONCLUSION The 20-gauge FNB needle outperformed the 25-gauge FNA needle in terms of histologic yield and diagnostic accuracy. This benefit was irrespective of the indication and was consistent among participating centers, supporting the general applicability of our findings. (Clinical trial registration number: NCT02167074.).
Collapse
|
14
|
The Successful Removal of a Broken Needle as an Unusual Complication of Endobronchial Ultrasound-guided Transbronchial Needle Aspiration (EBUS-TBNA): A Case Report and Literature Review. J UOEH 2019; 41:35-40. [PMID: 30867398 DOI: 10.7888/juoeh.41.35] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) is recommended for the diagnosis of mediastinal lymph nodes by the American College of Chest Physicians guidelines; however, the guidelines state that this procedure should only be performed by a trained bronchoscopist. Complications related to needle malfunction during the EBUS-TBNA procedure have recently been reported. We herein describe a rare case involving the successful management of a needle breakage that occurred as an unusual complication of EBUS-TBNA. An 81-year-old male patient with a medical history of myocardial infarction was introduced to our institution to undergo an evaluation for mediastinal and right hilar lymphadenopathy on chest computed tomography (CT). We performed EBUS-TBNA in a 14×10 mm subcarinal lymph node station using a 22 G aspiration needle (NA-201SX-4022, Vizishot®, Olympus, Japan) for diagnosing and staging of the patient's lung cancer. After the second aspiration, we noticed that the needle tip was broken and that it was stuck in the right main bronchus. We immediately removed the broken needle tip from the right main bronchus by flexible bronchoscopy using an ID 8.5 mm tracheal tube without cuff inflation. The length of the needle tip was 13 mm and it was considerably bent. The EBUS scope did not suffer any apparent damage. The patient did not have any other procedure-related complications. Needle breakage during EBUS-TBNA is rare; however, inhaling or swallowing of a broken needle tip has the potential to cause serious complications. Bronchoscopists should therefore be aware of the possibility of needle breakage, which is an important complication during EBUS-TBNA.
Collapse
|
15
|
Association between Tsukuba elasticity scores 4 and 5 on elastography and Bethesda undetermined cytology on US-guided FNA with 27-G needle, verified by histopathology: a cut-off point of 20 mm of diameter designated for thyroid nodules. JOURNAL OF B.U.ON. : OFFICIAL JOURNAL OF THE BALKAN UNION OF ONCOLOGY 2019; 24:382-390. [PMID: 30941995] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
PURPOSE The purpose of this study was to assess the performance of strain elastography (SE) in predicting malignancy for the thyroid nodules with undetermined cytology, Bethesda categories III and IV. The cut-off point was 20 mm of a thyroid nodule. METHODS A retrospective analysis from April 2012 to April 2016 was conducted by examining the records of 547 consecutive eligible patients with 655 thyroid nodules, the undetermined cytology of which surgery had been recommended. RESULTS A sum of 655 nodules in 547 patients were studied. Eighty-two (12.5%) of 655 thyroid nodules were Bethesda Category III and IV (undetermined cytology). Of the 655 thyroid nodules examined, 401 (61.2%) were less than 20 mm and 254 (38.8%) were more than 20 mm in diameter. No significant difference was detected between nodule sizes more than 20 mm in diameter and Tsukuba Elasticity score (TES) 4 and 5 by McNemar test and 0.677 area under the curve (AUC). No significant difference was detected between nodule sizes over 20 mm in diameter and Bethesda III and IV (undetermined cytology) by McNemar test and 0.632 AUC. In addition, no significant difference was detected between nodule size with the cut-off value of 20 mm and the histopathology of the thyroidectomies by McNemar test and 0.607 AUC. CONCLUSION Nodules size 20 mm in diameter was not a useful cut-off point for distinguishing malignant from benign thyroid nodules among the nodules with TES 4 and 5, Bethesda III and IV, and malignant histopathology.
Collapse
|
16
|
Endoscopic ultrasound (EUS) guided fine needle biopsy (FNB) with the Procore™ needle provides inadequate material for the histological diagnosis of early chronic pancreatitis. REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS 2018; 110:510-514. [PMID: 29722271 DOI: 10.17235/reed.2018.5164/2017] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
BACKGROUND diagnosis of early chronic pancreatitis (CP) is hampered due to the low accuracy of current imaging techniques and the absence of methods for histological confirmation. We aimed to evaluate the efficacy of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) for the histological diagnosis of early CP. METHODS a prospective, cross-sectional, single-center study was designed. Consecutive patients referred for EUS with a clinical suspicion of CP were evaluated for inclusion into the study. Inclusion criteria were age > 18 years and indeterminate EUS findings for the diagnosis of CP according to the Rosemont classification. EUS-FNB of the body of the pancreas was performed with Procore™ needles. Tissue samples were immersed into a methanol-based buffered preservative solution for cytohistological evaluation. The quality of the samples obtained and the histological findings were evaluated. Procedure-related complications were recorded. RESULTS the study was stopped after eleven patients were included due to safety concerns and poor diagnostic yield. The mean age of the patients was 50.3 years (range 33-70 years) and six were male. Samples were of poor quality in five cases, but were sufficient for cell-block evaluation. An inflammatory infiltration with mild fibrosis was identified in two cases and neither inflammatory infiltration nor fibrosis was identified in three cases. With regard to the other six cases, isolated inflammatory cells were observed in one case, although the cellularity was poor and unsuitable for cytological evaluation in five cases. There was one major complication (9.1%) of acute pancreatitis that required hospitalization for 48 hours. CONCLUSION EUS-FNB is technically feasible in patients with EUS findings categorized as indeterminate for a CP diagnosis. However, the diagnostic yield is poor and there is a non-negligible risk of complications.
Collapse
|
17
|
Comparison of endoscopic ultrasound-guided fine-needle aspiration and biopsy with 22-gauge and 25-gauge needles for the "precision medicine" of pancreatic cancer: A retrospective study. Medicine (Baltimore) 2018; 97:e11096. [PMID: 29901627 PMCID: PMC6023851 DOI: 10.1097/md.0000000000011096] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
Abstract
We compared the sample volume of endoscopic ultrasound-guided fine-needle aspiration and biopsy (EUS-FNAB) specimens obtained by 22-gauge (22G) and 25-gauge (25G) needles, and the accuracy rate.This was a retrospective study in a single tertiary referral center. We investigated 153 patients with pancreatic ductal adenocarcinoma (PDAC) who underwent diagnostic EUS-FNAB before neoadjuvant gemcitabine-based chemoradiotherapy between October 2006 and November 2015. We performed immunohistochemical (IHC) analysis of human equilibrative nucleoside transporter 1 using the remnant cell blocks following pathological PDAC diagnosis. We compared the sampling rate, accuracy rate, and success rate of IHC analysis between 22G and 25G.There were 70 patients in the 22G group and 83 patients in the 25G group. The overall sampling rates on cytology and histology were 100% and 98.0%, respectively. The sampling rate did not differ between the 22G and 25G groups. The overall diagnostic accuracy rates on cytology and histology were 94.8% and 79.7%, respectively. The accuracy rates of 22G and 25G groups on cytology were 94.3% and 95.2%, respectively, whereas those on histology were 80.0% and 79.5%, respectively. The diagnostic accuracy on cytology and histology did not differ significantly between the 22G and 25G groups. Of 153 histology specimens, 69.3% of those with PDAC provided sufficient samples for IHC analysis. The success rate of IHC analysis did not differ significantly between the 22G (67.1%) and 25G (71.1%) groups (P = .60).Both 22G and 25G provided a high diagnostic yield with equivalent accuracy rates on histology. EUS-FNAB specimens obtained using 22G or 25G can be equally adequate for IHC analysis and may be suitable for diagnostic examination. Further investigations such as EUS-FNAB needle design and novel cell block preparation are needed to obtain adequate samples for use in "precision medicine."
Collapse
|
18
|
Impact of Franseen needle on rapid onsite evaluation and histological examination following endoscopic ultrasonography-guided tissue acquisition in patients with splenic malignant lymphoma. Arab J Gastroenterol 2018; 19:91-95. [PMID: 29858116 DOI: 10.1016/j.ajg.2018.03.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/01/2018] [Revised: 03/05/2018] [Accepted: 03/15/2018] [Indexed: 12/27/2022]
Abstract
Rapid onsite evaluation (ROSE) following endoscopic ultrasonography (EUS)-guided fine-needle aspiration contributes to the establishment of a diagnosis for various organs. Newly designed three-plane symmetric needles for EUS-guided fine-needle biopsy (EUS-FNB), such as the Franseen needle, have been developed to enable histological core tissue acquisition. However, EUS-guided tissue acquisition for hypervascular splenic lesions remains challenging. Tissue acquisition in cases of splenic malignant lymphoma by using a conventional needle with multiple strokes and suction may result in indeterminate ROSE due to blood contamination and tiny fragments of lymphoma tissue, whereas EUS-FNB by using the Franseen needle with a minimal number of strokes with suction demonstrates qualified specimens for the ROSE as well as histological examination. For splenic malignant lymphomas, EUS-FNB by using the Franseen needle with a limited number of strokes may facilitate qualified specimen acquisition.
Collapse
|
19
|
A retrospective analysis comparing the use of ProCore® with standard fine needle aspiration in endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). Ir J Med Sci 2018; 188:85-88. [PMID: 29693234 DOI: 10.1007/s11845-018-1816-z] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2017] [Accepted: 04/13/2018] [Indexed: 02/06/2023]
Abstract
Endobronchial ultrasound has become first line in the investigation of mediastinal lesions suspicious for malignancy in keeping with National Institute for Health and Care Excellence (NICE) guidelines; however, needle size and type required to maximise diagnostic sensitivity remains unclear. Previous meta-analyses have compared the use of ProCore with standard fine needle aspiration in the assessment of pancreatic masses with differences noted only in the number of passes required. We aim to assess whether a ProCore needle improves diagnostic sensitivity in EBUS-TBNA. Complete follow-up data regarding all 235 patients undergoing EBUS-TBNA in a district general hospital has been collected since the service's inception in 2012. Results were collated and retrospectively analysed allowing for calculation of test sensitivity and specificity. Comparison was then made between procedures where standard fine needle aspiration was performed and those using a ProCore needle. Overall sensitivity of EBUS-TBNA was shown to be 85% with a specificity of 100% in keeping with quoted figures from other centres. Standard fine needle aspiration produced a sensitivity of 77% (85/110) versus ProCore sensitivity of 92% (115/125) with a p value of 0.0016. Thirty percent (33/110) of patients undergoing standard fine needle aspiration required an appropriate crossover technique such as mediastinoscopy or CT-guided FNA in order to either obtain or confirm the diagnosis compared with 15% (19/125) of the ProCore group with a p value of 0.0064. Our retrospective analysis shows a statistically significant difference in the diagnostic sensitivity of sampling mediastinal lymphadenopathy using a ProCore needle compared with standard fine needle aspiration. It also shows that a significantly fewer number of patients required further procedures in order to obtain or confirm the diagnosis. This could potentially be confounded by the retrospective nature of the study design; however, due to the statistical significance demonstrated, further study is required.
Collapse
|
20
|
A 19-Gauge Histology Needle Versus a 19-Gauge Standard Needle in Endoscopic Ultrasound-Guided Fine-Needle Aspiration for Solid Lesions: A Multicenter Randomized Comparison Study (GREATER Study). Dig Dis Sci 2018; 63:1043-1051. [PMID: 29464585 DOI: 10.1007/s10620-018-4913-y] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/05/2017] [Accepted: 01/02/2018] [Indexed: 12/27/2022]
Abstract
BACKGROUND The necessity of histological analysis is increasing. A 19-gauge histology needle (PC19) in endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) has recently been developed and has shown high yields of tissue acquisition and histological diagnosis. AIMS To compare the histological diagnostic yield in single-pass EUS-FNA for solid lesions using PC19 and a standard 19-gauge needle (EC19). PATIENTS AND METHODS Consecutive patients with solid lesions were enrolled and underwent one pass with each of PC19 and EC19 for EUS-FNA with the randomized order of the needles. The primary endpoint was the histological diagnostic accuracy. The secondary endpoints were the feasibility, yield of histological core, cytological and overall diagnostic accuracies, and adverse events. Subgroup analysis was performed for the optimal situation with PC19. RESULTS Of the 115 patients, 110 underwent EUS-FNA and five were excluded. EUS-FNA was performed from the esophagus in four, stomach in 80, or duodenum in 26. The final diagnosis was malignancy in 100 and benign in 10. The feasibility was 98.2 and 97.3% with PC19 and EC19, respectively (p = 1.00). The rate of presence of a histological core and the histological, cytological, and overall diagnostic accuracies for PC19 versus EC19 were 84.6 versus 80.9% (p = 0.593), 83.6 versus 73.6% (p = 0.099), 63.6 versus 56.4% (p = 0.335), and 90.0 versus 79.1% (p = 0.039), respectively. PC19 was favored in the trans-esophageal/gastric approaches to obtain a histological diagnosis (p = 0.013). Adverse events were observed in four patients. CONCLUSION Single-pass EUS-FNA with PC19 was feasible and showed significantly higher overall diagnostic accuracy and an increased tendency towards histological diagnostic accuracy, especially with trans-esophageal/gastric FNA.
Collapse
|
21
|
Comparison Study of the Adequacy and Pain Scale of Ultrasound-Guided Fine-Needle Aspiration of Solid Thyroid Nodules with a 21- or 23-Gauge Needle for Liquid-Based Cytology: a Single-Center Study. Endocr Pathol 2018; 29:30-34. [PMID: 29275502 DOI: 10.1007/s12022-017-9508-1] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
No published study has compared the cytological adequacy between different caliber needles in liquid-based cytology (LBC) after fine-needle aspiration (FNA) of thyroid nodules. This study aimed to compare cytological adequacy, pain scale, and associated complications depending on the use of a 21- and 23-gauge needle in LBC. From January 2017 to April 2017, 88 solid thyroid nodules (STNs) in 88 patients underwent consecutive ultrasonography (US)-guided FNA (US-FNA) by a single radiologist. The selection of the needle size was randomized and changed biweekly. After FNA, the pain scale and other complications related to FNA were immediately evaluated for each patient. In all cases, adequacy and cellularity in cytology were retrospectively investigated by a single cytopathologist. Of the 88 STNs, 10 (11.4%) showed inadequate cytology: 6 for 21-gauge and 4 for 23-gauge needles. The rate of cytological adequacy was higher in the 23-gauge needle group than in the 21-gauge group, but this was not statistically significant (p = 0.318). The mean values of the pain scale in the 21- and 23-gauge needle groups were 1.8 ± 1.3 and 1.4 ± 1.1, respectively, but this difference was not statistically significant (p = 0.567). There were no significant complications associated with US-FNA, except for one case of mild intrathyroidal hemorrhage. In US-FNA of STNs using LBC, the use of a 23-gauge needle may be recommended rather than a 21-gauge needle.
Collapse
|
22
|
Linear probe 19-gauge endobronchial ultrasound diagnosis of a benign chondroid hamartoma. Monaldi Arch Chest Dis 2018; 88:890. [PMID: 29557579 DOI: 10.4081/monaldi.2018.890] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2017] [Revised: 10/12/2017] [Accepted: 01/28/2018] [Indexed: 02/07/2023] Open
Abstract
We report a case of a 68-year-old gentleman, found to have a right hilar soft tissue mass whilst undergoing CT staging for prostate cancer. MRI imaging showed a heterogenous, enhancing solid mass without evidence of fat content. A linear probe endobronchial ultrasound-guided transbronchial needle aspiration was performed using a 19G needle. This confirmed the diagnosis of a benign chondroid hamartoma, avoiding the need for more invasive surgical biopsy.
Collapse
|
23
|
Diagnostic yield of EUS-FNA of small (≤15 mm) solid pancreatic lesions using a 25-gauge needle. Hepatobiliary Pancreat Dis Int 2018; 17:70-74. [PMID: 29428108 DOI: 10.1016/j.hbpd.2018.01.010] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/13/2017] [Accepted: 06/22/2017] [Indexed: 02/06/2023]
Abstract
BACKGROUND Early detection of small solid pancreatic lesions is increasingly common. To date, few and contradictory data have been published about the relationship between lesion size and endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) diagnostic yield. The aim of this study was to assess the relation between the size of solid pancreatic lesions and the diagnostic yield of EUS-FNA using a 25-gauge needle in a center without available rapid on-site evaluation. METHODS In the retrospective cohort study, we selected patients who underwent EUS-FNA for solid pancreatic lesions with a 25-gauge needle from October 2014 to October 2015. Patients were divided into three groups (≤15 mm, 16-25 mm and >25 mm), and the outcomes were compared. RESULTS We analyzed 163 patients. Overall adequacy, sensitivity, specificity and accuracy were 85.2%, 81.8%, 93.7%, and 80.4%, respectively. When stratified by size, the sensitivity and accuracy correlated with size (P = 0.016 and P = 0.042, respectively). Multivariate analysis showed that lesion size was the only independent factor (P = 0.019, OR = 4.76) affecting accuracy. The role of size as an independent factor affecting accuracy was confirmed in a separate multivariate analysis, where size was included in the model as a covariate (P = 0.018, OR = 1.08). CONCLUSION Our study demonstrates that, in the absence of rapid on-site evaluation, mass size affects the accuracy of EUS-FNA of solid pancreatic lesions.
Collapse
|
24
|
Comparison of 22-gauge standard fine needle versus core biopsy needle for endoscopic ultrasound-guided sampling of suspected pancreatic cancer: a randomized crossover trial. Scand J Gastroenterol 2018; 53:94-99. [PMID: 29065734 DOI: 10.1080/00365521.2017.1390597] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/15/2017] [Accepted: 10/02/2017] [Indexed: 02/04/2023]
Abstract
BACKGROUND Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is effective for tissue diagnosis of pancreatic mass. To improve diagnostic yield and drawbacks, 22-gauge (G) core biopsy (FNB) needle has been developed. This study aims to compare 22G FNA and FNB needles for EUS-guided sampling of suspected pancreatic cancer. METHODS This is a randomized controlled crossover trial. A total of 60 patients with suspected unresectable pancreatic cancer referred for EUS-guided sampling were randomly assigned to two groups. Both groups had 22G FNA and FNB needles performed in a randomized order. The primary endpoint was the cytological, histological and overall diagnostic accuracy of pancreatic cancer. RESULTS FNA and FNB needles reported similar level of diagnostic accuracy (FNA needle 95% vs. FNB needle 93.3%; p = .564), and it was not statistically different. However, cytological cellularity was significantly higher in the FNB needles compared to FNA needles (odds ratio 2.75, 95% confidence interval (CI)). There were no procedure-related complications in both needles. CONCLUSIONS The diagnostic accuracy of EUS-guided sampling for pancreatic cancer using 22G FNA is comparable to FNB needles. The cytological quality of specimen is better in the FNB needle.
Collapse
|
25
|
A comparison of the efficiency of 22G versus 25G needles in EUS-FNA for solid pancreatic mass assessment: A systematic review and meta-analysis. Clinics (Sao Paulo) 2018; 73:e261. [PMID: 29451621 PMCID: PMC5773825 DOI: 10.6061/clinics/2018/e261] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/04/2017] [Accepted: 10/31/2017] [Indexed: 12/17/2022] Open
Abstract
Our aim in this study was to compare the efficiency of 25G versus 22G needles in diagnosing solid pancreatic lesions by EUS-FNA. We performed a systematic review and meta-analysis. Studies were identified in five databases using an extensive search strategy. Only randomized trials comparing 22G and 25G needles were included. The results were analyzed by fixed and random effects. A total of 504 studies were found in the search, among which 4 randomized studies were selected for inclusion in the analysis. A total of 462 patients were evaluated (233: 25G needle/229: 22G needle). The diagnostic sensitivity was 93% for the 25G needle and 91% for the 22G needle. The specificity of the 25G needle was 87%, and that of the 22G needle was 83%. The positive likelihood ratio was 4.57 for the 25G needle and 4.26 for the 22G needle. The area under the sROC curve for the 25G needle was 0.9705, and it was 0.9795 for the 22G needle, with no statistically significant difference between them (p=0.497). Based on randomized studies, this meta-analysis did not demonstrate a significant difference between the 22G and 25G needles used during EUS-FNA in the diagnosis of solid pancreatic lesions.
Collapse
|
26
|
Interventional endoscopic ultrasound for a symptomatic pseudocyst secondary to gastric heterotopic pancreas. World J Gastroenterol 2017; 23:6365-6370. [PMID: 28974904 PMCID: PMC5603504 DOI: 10.3748/wjg.v23.i34.6365] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2017] [Revised: 07/10/2017] [Accepted: 08/02/2017] [Indexed: 02/07/2023] Open
Abstract
Heterotopic pancreas (HP) is a relatively uncommon entity that is defined as pancreatic tissue without a true anatomical or vascular connection to the pancreas. HP does not cause symptoms in most cases but can occasionally produce various manifestations, including nausea, vomiting, abdominal pain, and even heterotopic pancreatitis. Here, we report an unusual case in which heterotopic pancreatitis complicated by the formation of a pseudocyst that caused gastric outlet obstruction was diagnosed based on serum hyperamylasemia and findings from endoscopic ultrasonography (EUS)-guided fine needle aspiration (EUS-FNA) cytology. EUS-guided single pigtail stent insertion was successfully performed for recurrent gastric outlet obstruction. The patient has remained healthy and symptom-free during 4 years of surveillance. In the context of the relevant literature, the described case is a rare case of HP complicated by a pseudocyst treated via EUS-FNA and stent insertion.
Collapse
|
27
|
Development and Phantom Validation of a 3-D-Ultrasound-Guided System for Targeting MRI-Visible Lesions During Transrectal Prostate Biopsy. IEEE Trans Biomed Eng 2017; 64:946-958. [PMID: 27337710 PMCID: PMC5053368 DOI: 10.1109/tbme.2016.2582734] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVE Three- and four-dimensional transrectal ultrasound transducers are now available from most major ultrasound equipment manufacturers, but currently are incorporated into only one commercial prostate biopsy guidance system. Such transducers offer the benefits of rapid volumetric imaging, but can cause substantial measurement distortion in electromagnetic tracking sensors, which are commonly used to enable 3-D navigation. In this paper, we describe the design, development, and validation of a 3-D-ultrasound-guided transrectal prostate biopsy system that employs high-accuracy optical tracking to localize the ultrasound probe and prostate targets in 3-D physical space. METHODS The accuracy of the system was validated by evaluating the targeted needle placement error after inserting a biopsy needle to sample planned targets in a phantom using standard 2-D ultrasound guidance versus real-time 3-D guidance provided by the new system. RESULTS The overall mean needle-segment-to-target distance error was 3.6 ± 4.0 mm and mean needle-to-target distance was 3.2 ± 2.4 mm. CONCLUSION A significant increase in needle placement accuracy was observed when using the 3-D guidance system compared with visual targeting of invisible (virtual) lesions using a standard B-mode ultrasound-guided biopsy technique.
Collapse
|
28
|
Stylet Use Does Not Improve Diagnostic Outcomes in Endobronchial Ultrasonographic Transbronchial Needle Aspiration: A Randomized Clinical Trial. Chest 2017; 151:636-642. [PMID: 27769775 PMCID: PMC6026257 DOI: 10.1016/j.chest.2016.10.005] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2016] [Revised: 08/05/2016] [Accepted: 10/05/2016] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND Endobronchial ultrasonographically guided transbronchial needle aspiration (EBUS-TBNA) of thoracic structures is a commonly performed tissue sampling technique. The use of an inner-stylet in the EBUS needle has never been rigorously evaluated and may be unnecessary. METHODS In a prospective randomized single-blind controlled clinical trial, patients with a clinical indication for EBUS-TBNA underwent lymph node sampling using both with-stylet and without-stylet techniques. Sample adequacy, diagnostic yield, and various cytologic quality measures were compared. RESULTS One hundred twenty-one patients were enrolled, with 194 lymph nodes sampled, each using both with-stylet and without-stylet techniques. There was no significant difference in sample adequacy or diagnostic yield between techniques. The without-stylet technique resulted in adequate samples in 87% of the 194 study lymph nodes, which was no different from the with-stylet adequacy rate (82%; P = .371). The with-stylet technique resulted in a diagnosis in 50 of 194 samples (25.7%), which was similar to the without-stylet group (49 of 194 [25.2%]; P = .740). There was a high degree of concordance in the determination of adequacy (84.0%; 95% CI, 78.1-88.9) and diagnostic sample generation (95.4%; 95% CI, 91.2-97.9) between the two techniques. A similar qualitative number of lymphocytes, malignant cells, and bronchial respiratory epithelia were recovered using each technique. CONCLUSIONS Omitting stylet use during EBUS-TBNA does not affect diagnostic outcomes and reduces procedural complexity. TRIAL REGISTRY ClinicalTrials.Gov: No. NCT 02201654; URL:www.clinicaltrials.gov.
Collapse
|
29
|
Toward optical guidance during endoscopic ultrasound-guided fine needle aspirations of pancreatic masses using single fiber reflectance spectroscopy: a feasibility study. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:24001. [PMID: 28170030 DOI: 10.1117/1.jbo.22.2.024001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/16/2016] [Accepted: 01/12/2017] [Indexed: 05/04/2023]
Abstract
Endoscopic ultrasound-guided fine needle aspirations (EUS-FNA) of pancreatic masses suffer from sample errors and low-negative predictive values. Fiber-optic spectroscopy in the visible to near-infrared wavelength spectrum can noninvasively extract physiological parameters from tissue and has the potential to guide the sampling process and reduce sample errors. We assessed the feasibility of single fiber (SF) reflectance spectroscopy measurements during EUS-FNA of pancreatic masses and its ability to distinguish benign from malignant pancreatic tissue. A single optical fiber was placed inside a 19-gauge biopsy needle during EUS-FNA and at least three reflectance measurements were taken prior to FNA. Spectroscopy measurements did not cause any related adverse events and prolonged procedure time with ? 5 ?? min . An accurate correlation between spectroscopy measurements and cytology could be made in nine patients (three benign and six malignant). The oxygen saturation and bilirubin concentration were significantly higher in benign tissue compared with malignant tissue (55% versus 21%, p = 0.038 ; 166 ?? ? mol / L versus 17 ?? ? mol / L , p = 0.039 , respectively). To conclude, incorporation of SF spectroscopy during EUS-FNA was feasible, safe, and relatively quick to perform. The optical properties of benign and malignant pancreatic tissue are different, implying that SF spectroscopy can potentially guide the FNA sampling.
Collapse
|
30
|
Comparison of two different size needles in endoscopic ultrasound-guided fine-needle aspiration for diagnosing solid pancreatic lesions: A meta-analysis of prospective controlled trials. Medicine (Baltimore) 2017; 96:e5802. [PMID: 28151856 PMCID: PMC5293419 DOI: 10.1097/md.0000000000005802] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND This meta-analysis aimed to provide a pooled analysis of prospective controlled trials comparing the diagnostic accuracy of 22-G and 25-G needles on endoscopic ultrasonography (EUS-FNA) of the solid pancreatic mass. METHODS We established a rigorous study protocol according to Cochrane Collaboration recommendations. We systematically searched the PubMed and Embase databases to identify articles to include in the meta-analysis. Sensitivity, specificity, and corresponding 95% confidence intervals were calculated for 22-G and 25-G needles of individual studies from the contingency tables. RESULTS Eleven prospective controlled trials included a total of 837 patients (412 with 22-G vs 425 with 25-G). Our outcomes revealed that 25-G needles (92% [95% CI, 89%-95%]) have higher sensitivity than 22-G needles (88% [95% CI, 84%-91%]) on solid pancreatic mass EUS-FNA (P = 0.046). However, there were no significant differences between the 2 groups in overall diagnostic specificity (P = 0.842). The pooled positive and negative likelihood ratio of the 22-G needle were 12.61 (95% CI, 5.65-28.14) and 0.16 (95% CI, 0.12-0.21), respectively. The pooled positive likelihood ratio was 12.61 (95% CI, 5.65-28.14), and the negative likelihood ratio was 0.16 (95% CI, 0.12-0.21) for the 22-G needle. The pooled positive likelihood ratio was 8.44 (95% CI, 3.87-18.42), and the negative likelihood ratio was 0.13 (95% CI, 0.09-0.18) for the 25-G needle. The area under the summary receiver operating characteristic curve was 0.97 for the 22-G needle and 0.96 for the 25-G needle. CONCLUSION Compared to the study of 22-G EUS-FNA needles, our study showed that 25-G needles have superior sensitivity in the evaluation of solid pancreatic lesions by EUS-FNA.
Collapse
|
31
|
Diagnostic accuracy of 22/25-gauge core needle in endoscopic ultrasound-guided sampling: systematic review and meta-analysis. Korean J Intern Med 2016; 31:1073-1083. [PMID: 27586867 PMCID: PMC5094933 DOI: 10.3904/kjim.2016.066] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/10/2016] [Revised: 06/13/2016] [Accepted: 06/28/2016] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND/AIMS To compare the diagnostic accuracy of endoscopic ultrasound-guided core needle aspiration with that of standard fine-needle aspiration by systematic review and meta-analysis. METHODS Studies using 22/25-gauge core needles, irrespective of comparison with standard fine needles, were comprehensively reviewed. Pooled sensitivity, specificity, diagnostic odds ratio (DOR), and summary receiver operating characteristic curves for the diagnosis of malignancy were used to estimate the overall diagnostic efficiency. RESULTS The pooled sensitivity, specificity, and DOR of the core needle for the diagnosis of malignancy were 0.88 (95% confidence interval [CI], 0.84 to 0.90), 0.99 (95% CI, 0.96 to 1), and 167.37 (95% CI, 65.77 to 425.91), respectively. The pooled sensitivity, specificity, and DOR of the standard needle were 0.84 (95% CI, 0.79 to 0.88), 1 (95% CI, 0.97 to 1), and 130.14 (95% CI, 34.00 to 495.35), respectively. The area under the curve of core and standard needle in the diagnosis of malignancy was 0.974 and 0.955, respectively. The core and standard needle were comparable in terms of pancreatic malignancy diagnosis. There was no significant difference in procurement of optimal histologic cores between core and standard needles (risk ratio [RR], 0.545; 95% CI, 0.187 to 1.589). The number of needle passes for diagnosis was significantly lower with the core needle (standardized mean difference, -0.72; 95% CI, -1.02 to -0.41). There were no significant differences in overall complications (RR, 1.26; 95% CI, 0.34 to 4.62) and technical failure (RR, 5.07; 95% CI, 0.68 to 37.64). CONCLUSIONS Core and standard needles were comparable in terms of diagnostic accuracy, technical performance, and safety profile.
Collapse
|
32
|
22-gauge core vs 22-gauge aspiration needle for endoscopic ultrasound-guided sampling of abdominal masses. World J Gastroenterol 2016; 22:8820-8830. [PMID: 27818598 PMCID: PMC5075557 DOI: 10.3748/wjg.v22.i39.8820] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/25/2016] [Revised: 08/21/2016] [Accepted: 09/14/2016] [Indexed: 02/06/2023] Open
Abstract
AIM To compare the aspiration needle (AN) and core biopsy needle (PC) in endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) of abdominal masses.
METHODS Consecutive patients referred for EUS-FNA were included in this prospective single-center trial. Each patient underwent a puncture of the lesion with both standard 22-gauge (G) AN (Echo Tip Ultra; Cook Medical, Bloomington, Indiana, United States) and the novel 22G PC (EchoTip ProCore; Cook Medical, Bloomington, Indiana, United States) in a randomized fashion; histology was attempted in the PC group only. The main study endpoint was the overall diagnostic accuracy, including the contribution of histology to the final diagnosis. Secondary outcome measures included material adequacy, number of needle passes, and complications.
RESULTS Fifty six consecutive patients (29 men; mean age 68 years) with pancreatic lesions (n = 38), lymphadenopathy (n = 13), submucosal tumors (n = 4), or others lesions (n = 1) underwent EUS-FNA using both of the needles in a randomized order. AN and PC reached similar overall results for diagnostic accuracy (AN: 88.9 vs PC: 96.1, P = 0.25), specimen adequacy (AN: 96.4% vs PC: 91.1%, P = 0.38), mean number of passes (AN: 1.5 vs PC: 1.7, P = 0.14), mean cellularity score (AN: 1.7 vs PC: 1.1, P = 0.058), and complications (none). A diagnosis on the basis of histology was achieved in the PC group in 36 (64.3%) patients, and in 2 of those as the sole modality. In patients with available histology the mean cellularity score was higher for AN (AN: 1.7 vs PC: 1.0, P = 0.034); no other differences were of statistical significance.
CONCLUSION Both needles achieved high overall diagnostic yields and similar performance characteristics for cytological diagnosis; histological analysis was only possible in 2/3 of cases with the new needle.
Collapse
|
33
|
EUS Needle Identification Comparison and Evaluation study (with videos). Gastrointest Endosc 2016; 84:424-433.e2. [PMID: 26873530 PMCID: PMC5570521 DOI: 10.1016/j.gie.2016.01.068] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/24/2015] [Accepted: 01/29/2016] [Indexed: 02/08/2023]
Abstract
BACKGROUND AND AIMS EUS-guided FNA or biopsy sampling is widely practiced. Optimal sonographic visualization of the needle is critical for image-guided interventions. Of the several commercially available needles, bench-top testing and direct comparison of these needles have not been done to reveal their inherent echogenicity. The aims are to provide bench-top data that can be used to guide clinical applications and to promote future device research and development. METHODS Descriptive bench-top testing and comparison of 8 commonly used EUS-FNA needles (all size 22 gauge): SonoTip Pro Control (Medi-Globe); Expect Slimline (Boston Scientific); EchoTip, EchoTip Ultra, EchoTip ProCore High Definition (Cook Medical); ClearView (Conmed); EZ Shot 2 (Olympus); and BNX (Beacon Endoscopic), and 2 new prototype needles, SonoCoat (Medi-Globe), coated by echogenic polymers made by Encapson. Blinded evaluation of standardized and unedited videos by 43 EUS endoscopists and 17 radiologists specialized in GI US examination who were unfamiliar with EUS needle devices. RESULTS There was no significant difference in the ratings and rankings of these needles between endosonographers and radiologists. Overall, 1 prototype needle was rated as the best, ranking 10% to 40% higher than all other needles (P < .01). Among the commercially available needles, the EchoTip Ultra needle and the ClearView needle were top choices. The EZ Shot 2 needle was ranked statistically lower than other needles (30%-75% worse, P < .001). CONCLUSIONS All FNA needles have their inherent and different echogenicities, and these differences are similarly recognized by EUS endoscopists and radiologists. Needles with polymeric coating from the entire shaft to the needle tip may offer better echogenicity.
Collapse
|
34
|
Modelling and characterisation of a ultrasound-actuated needle for improved visibility in ultrasound-guided regional anaesthesia and tissue biopsy. ULTRASONICS 2016; 69:38-46. [PMID: 27022669 DOI: 10.1016/j.ultras.2016.02.018] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/07/2016] [Revised: 02/25/2016] [Accepted: 02/26/2016] [Indexed: 06/05/2023]
Abstract
Clear needle visualisation is recognised as an unmet need for ultrasound guided percutaneous needle procedures including regional anaesthesia and tissue biopsy. With inadequate needle visibility, these procedures may result in serious complications or a failed operation. This paper reports analysis of the modal behaviour of a previously proposed ultrasound-actuated needle configuration, which may overcome this problem by improving needle visibility in colour Doppler imaging. It uses a piezoelectric transducer to actuate longitudinal resonant modes in needles (outer diameter 0.8-1.2mm, length>65mm). The factors that affect the needle's vibration mode are identified, including the needle length, the transducer's resonance frequency and the gripping position. Their effects are investigated using finite element modelling, with the conclusions validated experimentally. The actuated needle was inserted into porcine tissue up to 30mm depth and its visibility was observed under colour Doppler imaging. The piezoelectric transducer is able to generate longitudinal vibration with peak-to-peak amplitude up to 4μm at the needle tip with an actuating voltage of 20Vpp. Actuated in longitudinal vibration modes (distal mode at 27.6kHz and transducer mode at 42.2kHz) with a drive amplitude of 12-14Vpp, a 120mm needle is delineated as a coloured line in colour Doppler images, with both needle tip and shaft visualised. The improved needle visibility is maintained while the needle is advanced into the tissue, thus allowing tracking of the needle position in real time. Moreover, the needle tip is highlighted by strong coloured artefacts around the actuated needle generated by its flexural vibration. A limitation of the technique is that the transducer mode requires needles of specific lengths so that the needle's resonance frequency matches the transducer. This may restrict the choice of needle lengths in clinical applications.
Collapse
|
35
|
Prospective Study for Comparison of Endoscopic Ultrasound-Guided Tissue Acquisition Using 25- and 22-Gauge Core Biopsy Needles in Solid Pancreatic Masses. PLoS One 2016; 11:e0154401. [PMID: 27149404 PMCID: PMC4858215 DOI: 10.1371/journal.pone.0154401] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2015] [Accepted: 04/13/2016] [Indexed: 02/07/2023] Open
Abstract
Background and Aims Although thicker needles theoretically allow more tissue to be collected, their decreased flexibility can cause mechanical damage to the endoscope, technical failure, and sample blood contamination. The effects of needle gauge on diagnostic outcomes of endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) of pancreatic mass lesions remain unknown. This study compared procurement rates of histologic cores obtained from EUS-FNB of pancreatic masses using 25- and 22-gauge core biopsy needles. Patients and Methods From March 2014 to July 2014, 66 patients with solid pancreatic mass underwent EUS-FNB with both 25- and 22-gauge core biopsy needles. Among them, 10 patients were excluded and thus 56 patients were eligible for the analyses. Needle sequences were randomly assigned, and two passes were made with each needle, consisting of 10 uniform to-and-fro movements on each pass with 10 mL syringe suction. A pathologist blinded to needle sequence evaluated specimens for the presence of histologic core. Results The mean patient age was 65.8 ± 9.5 years (range, 44–89 years); 35 patients (62.5%) were men. The mean pancreatic mass size was 35.3 ± 17.1 mm (range 14–122.3 mm). Twenty-eight patients (50%) had tumors at the pancreas head or uncinate process. There were no significant differences in procurement rates of histologic cores between 25-gauge (49/56, 87.5%) and 22-gauge (46/56, 82.1%, P = 0.581) needles or diagnostic accuracy using only histologic cores (98% and 95%). There were no technical failures or procedure-related adverse events. Conclusions The 25-gauge core biopsy needle could offer acceptable and comparable outcomes regarding diagnostic performance including histologic core procurement rates compared to the 22-gauge core biopsy needle, although the differences were not statistically significant. Trial Registration ClinicalTrials.gov NCT01795066
Collapse
|
36
|
EFSUMB Guidelines on Interventional Ultrasound (INVUS), Part IV - EUS-guided Interventions: General aspects and EUS-guided sampling (Long Version). ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2016; 37:E33-E76. [PMID: 27058434 DOI: 10.1055/s-0035-1553785] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The fourth part of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) Guidelines on Interventional Ultrasound describes general aspects of endoscopic ultrasound-guided diagnostic and therapeutic interventions and assesses the evidence for endoscopic ultrasound-guided sampling. Endoscopic ultrasound combines the most advanced high-resolution ultrasound imaging of lesions within the wall and in the vicinity of the gastrointestinal tract and safe and effective fine needle based tissue acquisition from these lesions. The guideline addresses the indications, contraindications, techniques, adverse events, training and clinical impact of EUS-guided sampling. Advantages and drawbacks are weighed in comparison with image-guided percutaneous biopsy. Based on the most current evidence, clinical practice recommendations are given for crucial preconditions and steps of EUS-guided sampling as well as for safe performance. Additionally, the guideline deals with the principles and reliability of cytopathological reporting in endoscopic ultrasound-guided sampling (long version).
Collapse
|
37
|
EFSUMB Guidelines on Interventional Ultrasound (INVUS), Part IV - EUS-guided interventions: General Aspects and EUS-guided Sampling (Short Version). ULTRASCHALL IN DER MEDIZIN (STUTTGART, GERMANY : 1980) 2016; 37:157-169. [PMID: 26515966 DOI: 10.1055/s-0035-1553788] [Citation(s) in RCA: 49] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The fourth part of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) Guidelines on Interventional Ultrasound describes general aspects of endoscopic ultrasound-guided diagnostic and therapeutic interventions and assesses the evidence for endoscopic ultrasound-guided sampling. Endoscopic ultrasound combines the most advanced high-resolution ultrasound imaging of lesions within the wall and in the vicinity of the gastrointestinal tract and safe and effective fine needle-based tissue acquisition from these lesions. The guideline addresses the indications, contraindications, techniques, adverse events, training and clinical impact of EUS-guided sampling. Advantages and drawbacks are weighed in comparison with image-guided percutaneous biopsy. Based on the most current evidence, clinical practice recommendations are given for crucial preconditions and steps of EUS-guided sampling as well as for safe performance. Additionally, the guideline deals with the principles and reliability of cytopathological reporting in endoscopic ultrasound-guided sampling (short version; the long version is published online).
Collapse
|
38
|
Endoscopic ultrasonography guided-fine needle aspiration for the diagnosis of solid pancreaticobiliary lesions: Clinical aspects to improve the diagnosis. World J Gastroenterol 2016; 22:628-640. [PMID: 26811612 PMCID: PMC4716064 DOI: 10.3748/wjg.v22.i2.628] [Citation(s) in RCA: 69] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/27/2015] [Revised: 09/20/2015] [Accepted: 11/13/2015] [Indexed: 02/06/2023] Open
Abstract
Endoscopic ultrasonography-guided fine-needle aspiration (EUS-FNA) has been applied to pancreaticobiliary lesions since the 1990s and is in widespread use throughout the world today. We used this method to confirm the pathological evidence of the pancreaticobiliary lesions and to perform suitable therapies. Complications of EUS-FNA are quite rare, but some of them are severe. Operators should master conventional EUS observation and experience a minimum of 20-30 cases of supervised EUS-FNA on non-pancreatic and pancreatic lesions before attempting solo EUS-FNA. Studies conducted on pancreaticobiliary EUS-FNA have focused on selection of suitable instruments (e.g., needle selection) and sampling techniques (e.g., fanning method, suction level, with or without a stylet, optimum number of passes). Today, the diagnostic ability of EUS-FNA is still improving; the detection of pancreatic cancer (PC) currently has a sensitivity of 90%-95% and specificity of 95%-100%. In addition to PC, a variety of rare pancreatic tumors can be discriminated by conducting immunohistochemistry on the FNA materials. A flexible, large caliber needle has been used to obtain a large piece of tissue, which can provide sufficient histological information to be helpful in classifying benign pancreatic lesions. EUS-FNA can supply high diagnostic yields even for biliary lesions or peri-pancreaticobiliary lymph nodes. This review focuses on the clinical aspects of EUS-FNA in the pancreaticobiliary field, with the aim of providing information that can enable more accurate and efficient diagnosis.
Collapse
|
39
|
Convex-probe Endobronchial Ultrasound: A Decade of Progress. THE INDIAN JOURNAL OF CHEST DISEASES & ALLIED SCIENCES 2016; 58:21-35. [PMID: 28368567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Ever since the invention of the flexible bronchoscope, perhaps no other innovation in the field of interventional pulmonology has caused so much excitement the world over, as the convex probe endobronchial ultrasound (EBUS)-guided transbronchial needle aspiration (TBNA). While it took over a decade from 1992 to 2004 for the radial EBUS to evolve into the commercial convex probe EBUS scope, another exciting decade has gone by with the technology being thoroughly researched and appraised. The current evidence suggests that EBUS-TBNA can replace mediastinoscopy as the first investigation in the mediastinal staging of lung cancer. The use of EBUS-TBNA has been extended to several other areas including the diagnosis of undefined mediastinal lymphadenopathy, evaluation of intra-parenchymal lesions and others. In fact, EBUS-TBNA is the preferred modality for accessing mediastinal lesions in contact with the airways. The procedure not only has a high diagnostic efficiency (80%-90% for most indications) but is also safe compared to alternative options, such as image-guided fine needle aspiration and mediastinoscopy in the diagnosis of mediastinal lymphadenopathy. Apart from the traditional use of EBUS to perform TBNA, the last decade has seen the evolution of its transoesophageal use, development of novel EBUS-TBNA needles to obtain better histological specimens and a smaller EBUS scope. This review summarises the developments made in this field over the years since its inception.
Collapse
|
40
|
Diagnostic Yield and Complications Using a 20 Gauge Prostate Biopsy Needle versus a Standard 18 Gauge Needle: A Randomized Controlled Study. UROLOGY JOURNAL 2015; 12:2329-2333. [PMID: 26571315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Received: 05/12/2015] [Revised: 07/26/2015] [Accepted: 09/15/2015] [Indexed: 06/05/2023]
Abstract
PURPOSE To compare and evaluate whether a 20 gauge (20G) biopsy needle maintains a similar detection rate as that of the commonly used 18G needle for transrectal ultrasound-guided prostate biopsy (TRUSPB) aimed at assessing prostate cancer (PCa) and decreasing pain and complications. MATERIALS AND METHODS A total of 122 cases with indications of PCa were randomly allocated into two groups for this randomized controlled study. TRUSPB was performed randomly using either an 18G or 20G needle for core biopsies (62 cases with 18G and 60 cases with 20G). Detection rate, pain, and complications were assessed after the procedure. RESULTS The cancer detection rate in the 18G group (40.3%) did not differ from that in the 20G group (35.0%). However, the number of patients with pain was significantly lower in 20G group (P < 0.05). The number of patients with self-limiting hematuria decreased in both groups after the biopsy procedure (18G: 38 cases; 20G: 16 cases; P < .0001). Hematochezia occurred in 11 cases (9 cases [14.5%] in the 18G group; 2 cases [3.4%] in the 20G group). The number of patients with infection, dysuria, and urinary retention tended to be lower in 20G group. CONCLUSION Use of a 20G needle for TRUSPB yielded a comparable cancer detection rate to that of an 18G needle and led to less local injury, pain, and complications. A larger and more sensitive study is needed to verify our results.
Collapse
|
41
|
Effect of a stylet on a histological specimen in EUS-guided fine-needle tissue acquisition by using 22-gauge needles: a multicenter, prospective, randomized, controlled trial. Gastrointest Endosc 2015; 82:837-844.e1. [PMID: 25936452 DOI: 10.1016/j.gie.2015.03.1898] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/28/2014] [Accepted: 03/05/2015] [Indexed: 12/15/2022]
Abstract
BACKGROUND EUS-guided FNA (EUS-FNA) has become the most efficacious way to obtain specimens from a solid lesion adjacent to the GI tract. Previous reports regarding the use of a stylet during EUS-FNA were all based on cytological diagnosis and have showed no significant superiority in terms of diagnostic yield. OBJECTIVE To clarify the noninferiority of EUS-FNA without a stylet (S-) compared with EUS-FNA with a stylet (S+) on histological assessment. DESIGN A prospective, single-blind, randomized, controlled crossover study. SETTING Five tertiary referral centers in Japan. PATIENTS Patients referred for EUS-FNA of a solid lesion. INTERVENTION EUS-FNA S+ and S- in a total of 4 alternate passes with randomization to S+ first or S- first. MAIN OUTCOME MEASUREMENTS The primary endpoint was the acquisition rate of an appropriate and sufficient specimen for histological assessment. The secondary endpoints were cellularity, contamination, bloodiness, diagnostic ability, and diagnostic accuracy. RESULTS We enrolled 107 patients (110 lesions) and analyzed 220 specimens each in the S+ and S- groups. The acquisition rate of appropriate and sufficient specimens in the S+ group was 121 of 220 (55.0%) and 122 of 220 (55.5%) in the S- group. The difference in the acquisition rate of the specimen (S- minus S+) based on the generalized estimating equation was 0.42% (95% confidence interval, -6.72% to 7.56%), which was less than 10% of the prespecified noninferiority margin of this study. With regard to cellularity, contamination, bloodiness score, diagnostic ability, and diagnostic accuracy, there were no significant differences between both groups. There were no dropouts in the study. LIMITATIONS A variety of target lesions, multiple pathologists, lack of an assessment of intraobserver and interobserver variability, and a single-blind study for the pathologists. CONCLUSION EUS-FNA S- is noninferior to EUS-FNA S+ on histological assessment. ( CLINICAL TRIAL REGISTRATION NUMBER UMIN000008695.).
Collapse
|
42
|
Forward-viewing versus oblique-viewing echoendoscopes in the diagnosis of upper GI subepithelial lesions with EUS-guided FNA: a prospective, randomized, crossover study. Gastrointest Endosc 2015; 82:287-95. [PMID: 25816723 DOI: 10.1016/j.gie.2014.12.051] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2014] [Accepted: 12/21/2014] [Indexed: 12/12/2022]
Abstract
BACKGROUND The role of the forward-viewing echoendoscope compared with the oblique-viewing echoendoscope for EUS-guided FNA (EUS-FNA) of upper GI subepithelial lesions has not been defined. OBJECTIVE To compare the diagnostic yield and clinical efficacy of EUS-FNA by using the 2 echoendoscopes in the same upper GI subepithelial lesion. DESIGN Prospective, randomized, crossover study. SETTING Tertiary-care medical center. PATIENTS Forty-one patients with an upper GI subepithelial lesion. INTERVENTIONS All patients first underwent EUS-FNA with a 19-gauge needle by using both echoendoscopes, based on random selection. When required, 22-gauge or 25-gauge needles were used additionally. MAIN OUTCOME MEASUREMENTS Comparison of diagnostic yield, tissue sample area, puncture success rates, procedure time, and adverse events. RESULTS Forty-one patients (median lesion size 22 mm, range 15-63 mm) were enrolled. Rates of histologic diagnosis were 80.5% (33/41) and 73.2% (30/41) (P=.453) by using forward-viewing and oblique-viewing echoendoscopes, respectively. Median tissue sample area in GI stromal tumors (n=22) obtained with the forward-viewing echoendoscope was larger than with the oblique-viewing echoendoscope (2.46 mm2 vs 1.00 mm2; P=.046). Puncture success rates were 39 of 41 (95.1%) and 35 of 41 (85.4%; P=.289) with forward-viewing and oblique-viewing echoendoscopes, respectively. Median procedure time was 21 minutes with the forward-viewing echoendoscope and 27 minutes with the oblique-viewing echoendoscope (P=.009). An infectious adverse event occurred in a patient and was treated with antibiotics. LIMITATIONS Small sample size. CONCLUSION Diagnostic yield did not differ between the 2 echoendoscopes. However, tissue sample area and procedure time were superior with the forward-viewing echoendoscope.
Collapse
|
43
|
Needle Trajectory and Tip Localization in Real-Time 3-D Ultrasound Using a Moving Stylus. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:2057-2070. [PMID: 25929997 DOI: 10.1016/j.ultrasmedbio.2015.03.013] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/16/2014] [Revised: 03/04/2015] [Accepted: 03/11/2015] [Indexed: 06/04/2023]
Abstract
Described here is a novel approach to needle localization in 3-D ultrasound based on automatic detection of small changes in appearance on movement of the needle stylus. By stylus oscillation, including its full insertion into the cannula to the tip, the image processing techniques can localize the needle trajectory and the tip in the 3-D ultrasound volume. The 3-D needle localization task is reduced to two 2-D localizations using orthogonal projections. To evaluate our method, we tested it on three different ex vivo tissue types, and the preliminary results indicated that the method accuracy lies within clinical acceptance, with average error ranges of 0.9°-1.4° in needle trajectory and 0.8-1.1 mm in needle tip. Results also indicate that method performance is independent of the echogenicity of the tissue. This technique is a safe way of producing ultrasonic intensity changes and appears to introduce negligible risk to the patient, as the outer cannula remains fixed.
Collapse
|
44
|
Feasibility of endoscopic ultrasound (EUS) guided fine needle aspiration (FNA) and biopsy (FNB) with a new slim linear echoendoscope. REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS 2015; 107:359-365. [PMID: 26031864] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
BACKGROUND Endoscopic ultrasound (EUS) guided fine needle aspiration (FNA) and biopsy (FNB) is considered a very accurate and safe tool for sampling extra-intestinal tumors. Standard echoendosocopes for FNA/FNB are large with a sharpened tip that can be associated with complications. A new slim linearechoendoscope have been developed trying to overcome this limitation. AIM Of the present study was to evaluate the feasibility; safety and diagnostic yield of this newly developed slim echoendoscope for performing EUS-guided FNA/FNB. METHODS A pilot observational study was performed. Consecutive patients submitted for a EUS-FNA/FNB were prospectively included in the study. Patients underwent EUS procedure using the new slim linear PENTAX-echoendoscope. Tissue acquisition was done with standard and histology needles. Feasibility and diagnostic yield were evaluated. A descriptive analysis was performed. RESULTS 87 patients were included (mean age 66.7 years (range 24-90 years), 45 male. Mean size was of lesions sampled were 33.43 +/- 20.8 mm. Esophagus intubation and access to the second portion of the duodenum (D2) were considered easy in all 87 cases (100%). Nineteen procedures (21.8%) were performed from the esophagus, 42 (48.3%) from the stomach, 22 (25.3%) cases from duodenal bulb, and 4 (4.6%) cases from D2. EUS-FNB was feasible in 85 cases (97.7%), failed in 2 pancreatic lesions accessed from D2. Diagnostic yield was 86.21% (95%CI 77.4- 91.9) in the intention-to-treat analysis and 88.24% (95%CI 79.7- 93.5) in per-protocol analysis. There were no complications related to the technique. CONCLUSION Performing a EUS-FNA/FNB with the newly designed slim scope is feasible and safe for cyto-histopathology diagnosis of intra-intestinal and extra-intestinal mass lesions.
Collapse
|
45
|
[ERCP cytology & biopsy and EUS-FNA for biliary diseases]. NIHON RINSHO. JAPANESE JOURNAL OF CLINICAL MEDICINE 2015; 73 Suppl 3:530-538. [PMID: 25857081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
|
46
|
Endoscopic ultrasound guided fine needle aspiration and useful ancillary methods. World J Gastroenterol 2014; 20:14292-14300. [PMID: 25339816 PMCID: PMC4202358 DOI: 10.3748/wjg.v20.i39.14292] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2013] [Revised: 03/22/2014] [Accepted: 07/11/2014] [Indexed: 02/06/2023] Open
Abstract
The role of endoscopic ultrasound (EUS) in evaluating pancreatic pathology has been well documented from the beginning of its clinical use. High spatial resolution and the close proximity to the evaluated organs within the mediastinum and abdominal cavity allow detection of small focal lesions and precise tissue acquisition from suspected lesions within the reach of this method. Fine needle aspiration (FNA) is considered of additional value to EUS and is performed to obtain tissue diagnosis. Tissue acquisition from suspected lesions for cytological or histological analysis allows, not only the differentiation between malignant and non-malignant lesions, but, in most cases, also the accurate distinction between the various types of malignant lesions. It is well documented that the best results are achieved only if an adequate sample is obtained for further analysis, if the material is processed in an appropriate way, and if adequate ancillary methods are performed. This is a multi-step process and could be quite a challenge in some cases. In this article, we discuss the technical aspects of tissue acquisition by EUS-guided-FNA (EUS-FNA), as well as the role of an on-site cytopathologist, various means of specimen processing, and the selection of the appropriate ancillary method for providing an accurate tissue diagnosis and maximizing the yield of this method. The main goal of this review is to alert endosonographers, not only to the different possibilities of tissue acquisition, namely EUS-FNA, but also to bring to their attention the importance of proper sample processing in the evaluation of various lesions in the gastrointestinal tract and other accessible organs. All aspects of tissue acquisition (needles, suction, use of stylet, complications, etc.) have been well discussed lately. Adequate tissue samples enable comprehensive diagnoses, which answer the main clinical questions, thus enabling targeted therapy.
Collapse
|
47
|
Endoscopic ultrasound-guided fine-needle biopsy of small solid pancreatic lesions using a 22-gauge needle with side fenestration. Surg Endosc 2014; 29:1586-90. [PMID: 25303907 DOI: 10.1007/s00464-014-3846-6] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2014] [Accepted: 08/27/2014] [Indexed: 02/06/2023]
Abstract
BACKGROUND Early detection of small pancreatic cancer is important because expected survival is markedly better for tumors ≤ 2 cm. A new endoscopic ultrasound-(EUS) guided biopsy needle with side fenestration has been recently developed to enable fine-needle biopsy (FNB) under EUS guidance. The aim of this study was to evaluate the outcome of EUS-FNB using a 22-gauge ProCore needle in solid pancreatic lesions ≤ 2 cm, in terms of diagnostic accuracy and yield. METHODS From January 2011 to December 2012, all consecutive EUS-guided tissue sampling of small pancreatic lesions (≤ 2 cm) were performed using 22-gauge ProCore needles; the data of these patients were analyzed retrospectively. RESULTS Sixty-eight patients with a mean age of 65.7 years were included. The mean lesion size was 16.5 mm (range 5-20). None of the patients developed complications. On pathological examination, the tissue retrieved was judged adequate in 58 out of 68 cases (85.3 %) and the presence of a tissue core was recorded in 36 out of 68 cases (52.9 %). The overall sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 80, 100, 100, 40, and 82 %, respectively. CONCLUSION Our results suggested that EUS-FNB of small pancreatic lesions using a 22-gauge ProCore needle is effective and safe, and supports our hypothesis that EUS-FNB is highly useful in establishing the nature of small pancreatic lesions.
Collapse
|
48
|
Performance of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) needles. How to handle specimens? Minerva Med 2014; 105:323-331. [PMID: 25028866] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
|
49
|
[Diagnostic bronchoscopy]. KYOBU GEKA. THE JAPANESE JOURNAL OF THORACIC SURGERY 2014; 67:702-709. [PMID: 25138942] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Endoscopic technology has developed markedly with endobronchial ultrasonography (EBUS) having become dramatically widespread over the past 10 years. EBUS-guided transbronchial needle aspiration (EBUS-TBNA) has become an important modality for the mediastinal staging of lung cancer as well as mediastinoscopy. The combination of EBUS with a guide sheath( EBUS-GS) and virtual navigation systems, such as Bf-NAVI, LungPoint, superDimension/Bronchus system, is useful for diagnosis of small peripheral pulmonary lesions. Moreover, the ability to observe lesions has increased using picture enhancement developed by new methods such as autofluorescence imaging( AFI), narrow band imaging (NBI), and FUJI intelligent color enhancement( FICE). However, these modalities have limited value in detection of lung cancer and preneoplastic lesions. In recent years, the indications for AFI have widened and it can be now used for evaluation of tumor extension. Knowledge of these new technologies is certainly useful to allow their routine clinical use by respiratory surgeons. We will review these new technologies in this paper.
Collapse
|
50
|
Abstract
Endoscopic ultrasound-guided fine needle aspiration is a multistep procedure that involves proper clinical indication, correct selection of needles, adapting evidence-based techniques such as the fanning maneuver and not routinely using suction or the stylet for tissue sampling, and establishing reliable cytopathology support. Integrating cytopathology in the training curriculum and developing a more flexible platform of needles and echoendoscopes are likely to further advance the field of endosonography. This review aims to summarize the technical issues that are key to performing high-quality endoscopic ultrasound-guided fine needle aspiration.
Collapse
|