Han PK, Horng DE, Gong K, Petibon Y, Kim K, Li Q, Johnson KA, El Fakhri G, Ouyang J, Ma C. MR-based PET attenuation correction using a combined ultrashort echo time/multi-echo Dixon acquisition. Med Phys 2020; 47:3064-3077. [PMID: 32279317 DOI: 10.1002/mp.14180] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2019] [Revised: 03/26/2020] [Accepted: 04/02/2020] [Indexed: 12/11/2022] Open
Abstract
PURPOSE To develop a magnetic resonance (MR)-based method for estimation of continuous linear attenuation coefficients (LACs) in positron emission tomography (PET) using a physical compartmental model and ultrashort echo time (UTE)/multi-echo Dixon (mUTE) acquisitions. METHODS We propose a three-dimensional (3D) mUTE sequence to acquire signals from water, fat, and short T2 components (e.g., bones) simultaneously in a single acquisition. The proposed mUTE sequence integrates 3D UTE with multi-echo Dixon acquisitions and uses sparse radial trajectories to accelerate imaging speed. Errors in the radial k-space trajectories are measured using a special k-space trajectory mapping sequence and corrected for image reconstruction. A physical compartmental model is used to fit the measured multi-echo MR signals to obtain fractions of water, fat, and bone components for each voxel, which are then used to estimate the continuous LAC map for PET attenuation correction. RESULTS The performance of the proposed method was evaluated via phantom and in vivo human studies, using LACs from computed tomography (CT) as reference. Compared to Dixon- and atlas-based MRAC methods, the proposed method yielded PET images with higher correlation and similarity in relation to the reference. The relative absolute errors of PET activity values reconstructed by the proposed method were below 5% in all of the four lobes (frontal, temporal, parietal, and occipital), cerebellum, whole white matter, and gray matter regions across all subjects (n = 6). CONCLUSIONS The proposed mUTE method can generate subject-specific, continuous LAC map for PET attenuation correction in PET/MR.
Collapse
|
27
|
Sung Y, Tetrault MA, Takahashi K, Ouyang J, Pratx G, Fakhri GE, Normandin MD. Dependence of fluorodeoxyglucose (FDG) uptake on cell cycle and dry mass: a single-cell study using a multi-modal radiography platform. Sci Rep 2020; 10:4280. [PMID: 32152343 PMCID: PMC7062696 DOI: 10.1038/s41598-020-59515-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2019] [Accepted: 11/04/2019] [Indexed: 11/09/2022] Open
Abstract
High glucose uptake by cancer compared to normal tissues has long been utilized in fluorodeoxyglucose-based positron emission tomography (FDG-PET) as a contrast mechanism. The FDG uptake rate has been further related to the proliferative potential of cancer, specifically the proliferation index (PI) - the proportion of cells in S, G2 or M phases. The underlying hypothesis was that the cells preparing for cell division would consume more energy and metabolites as building blocks for biosynthesis. Despite the wide clinical use, mixed reports exist in the literature on the relationship between FDG uptake and PI. This may be due to the large variation in cancer types or methods adopted for the measurements. Of note, the existing methods can only measure the average properties of a tumor mass or cell population with highly-heterogeneous constituents. In this study, we have built a multi-modal live-cell radiography system and measured the [18F]FDG uptake by single HeLa cells together with their dry mass and cell cycle phase. The results show that HeLa cells take up twice more [18F]FDG in S, G2 or M phases than in G1 phase, which confirms the association between FDG uptake and PI at a single-cell level. Importantly, we show that [18F]FDG uptake and cell dry mass have a positive correlation in HeLa cells, which suggests that high [18F]FDG uptake in S, G2 or M phases can be largely attributed to increased dry mass, rather than the activities preparing for cell division. This interpretation is consistent with recent observations that the energy required for the preparation of cell division is much smaller than that for maintaining house-keeping proteins.
Collapse
|
28
|
Han PK, Horng DE, Marin T, Petibon Y, Ouyang J, El Fakhri G, Ma C. Free-Breathing Three-Dimensional T 1 Mapping of the Heart Using Subspace-Based Data Acquisition and Image Reconstruction. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:4008-4011. [PMID: 31946750 DOI: 10.1109/embc.2019.8856511] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Mapping the longitudinal relaxation time constant (T1) of the myocardium using Magnetic Resonance Imaging (MRI) is an emerging technique for quantitative assessment of the morphology and viability of the myocardium. However, three-dimensional (3D) T1 mapping of the heart is challenging due to the high dimensionality of the signal and the presence of cardiac and respiratory motions. We propose a subspace-based method for free-breathing 3D T1 mapping of the heart without respiratory gating. The image function is represented as a high-order partially separable (PS) function to explore the inherent spatiotemporal correlations of the underlying signal. A special data acquisition scheme enabled by the high-order PS model is used for sparse sampling of the (k,t)-space, where complementary sparse datasets are acquired, each covering only a small portion of the (k,t)-space to characterize a single subspace (spatial or temporal). High-resolution dynamic MR images are reconstructed from the highly undersampled (k,t)-space using low-rank tensor and sparsity constraints. We demonstrate the feasibility of our proposed method using in vivo data obtained from healthy subjects on a 3T MR scanner. The proposed method can enable new clinical applications of T1 mapping in cardiac MR.
Collapse
|
29
|
Feng PN, Liang YR, Lin WB, Yao ZR, Chen DB, Chen PS, Ouyang J. Homocysteine induced oxidative stress in human umbilical vein endothelial cells via regulating methylation of SORBS1. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES 2019; 22:6948-6958. [PMID: 30402861 DOI: 10.26355/eurrev_201810_16164] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE The aim of the present study was to investigate the mechanism of homocysteine (Hcy) induced oxidative stress in the human umbilical vein endothelial cells (HUVECs). PATIENTS AND METHODS The HUVECs were isolated from umbilical vein vascular wall of 12 patients and treated with Hcy. The malondialdehyde (MDA) level was measured using the thiobarbituric acid (TBA) method. The expressions of superoxide dismutase 2 (SOD2), endothelial nitric oxide synthase (eNOS), and intercellular adhesion molecule 1 (ICAM-1) were detected by Western blot and RT-PCR. The genome-wide DNA methylation assay was performed using the Infinium Human Methylation 450 BeadChip. The specific DNA methylation was determined using bisulfite sequencing analysis. To evaluate the role of sorbin and SH3 domain-containing protein 1 (SORBS1), the HUVECs were transfected with small interfere RNA (siRNA) targeting SORBS1 (SORBS1-siRNA). RESULTS Hcy induced MDA level in HUVECs, and increased ICAM-1 expression both in protein and mRNA levels. The protein and mRNA levels of SOD2 and eNOS were inhibited by Hcy induction. However, the effects of Hcy on MDA level and expressions of SOD2, eNOS, and ICAM-1 were attenuated by folic acid (Fc) and vitamin B12 (B12) treatment. DNA total methylation level in Hcy treated cells was significantly decreased compared to the control group, while the DNA total methylation levels were increased after treatment with Fc and B12. The methylation level of SORBS1 in Hcy treatment group was higher than that of control group. And the methylation level of SORBS1 induced by Hcy was attenuated by Fc and B12 treatment. SORBS1-siRNA transfection induced the MDA levels and reduced the expressions of SOD2 in HUVECs. CONCLUSIONS We indicated that Hcy induced oxidative stress in HUVECs via regulating methylation of SORBS1. We also found that Fc and B12 treatment attenuated the oxidative stress and inflammation induced by Hcy in HUVECs. The findings indicated that Fc and B12 might be effective agents for the treatment of Hcy induced AS.
Collapse
|
30
|
Sun T, Petibon Y, Han PK, Ma C, Kim SJW, Alpert NM, El Fakhri G, Ouyang J. Body motion detection and correction in cardiac PET: Phantom and human studies. Med Phys 2019; 46:4898-4906. [PMID: 31508827 DOI: 10.1002/mp.13815] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2019] [Revised: 08/28/2019] [Accepted: 08/28/2019] [Indexed: 12/14/2022] Open
Abstract
PURPOSE Patient body motion during a cardiac positron emission tomography (PET) scan can severely degrade image quality. We propose and evaluate a novel method to detect, estimate, and correct body motion in cardiac PET. METHODS Our method consists of three key components: motion detection, motion estimation, and motion-compensated image reconstruction. For motion detection, we first divide PET list-mode data into 1-s bins and compute the center of mass (COM) of the coincidences' distribution in each bin. We then compute the covariance matrix within a 25-s sliding window over the COM signals inside the window. The sum of the eigenvalues of the covariance matrix is used to separate the list-mode data into "static" (i.e., body motion free) and "moving" (i.e. contaminated by body motion) frames. Each moving frame is further divided into a number of evenly spaced sub-frames (referred to as "sub-moving" frames), in which motion is assumed to be negligible. For motion estimation, we first reconstruct the data in each static and sub-moving frame using a rapid back-projection technique. We then select the longest static frame as the reference frame and estimate elastic motion transformations to the reference frame from all other static and sub-moving frames using nonrigid registration. For motion-compensated image reconstruction, we reconstruct all the list-mode data into a single image volume in the reference frame by incorporating the estimated motion transformations in the PET system matrix. We evaluated the performance of our approach in both phantom and human studies. RESULTS Visually, the motion-corrected (MC) PET images obtained using the proposed method have better quality and fewer motion artifacts than the images reconstructed without motion correction (NMC). Quantitative analysis indicates that MC yields higher myocardium to blood pool concentration ratios. MC also yields sharper myocardium than NMC. CONCLUSIONS The proposed body motion correction method improves image quality of cardiac PET.
Collapse
|
31
|
Petibon Y, Sun T, Han PK, Ma C, Fakhri GE, Ouyang J. MR-based cardiac and respiratory motion correction of PET: application to static and dynamic cardiac 18F-FDG imaging. Phys Med Biol 2019; 64:195009. [PMID: 31394518 DOI: 10.1088/1361-6560/ab39c2] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
Motion of the myocardium deteriorates the quality and quantitative accuracy of cardiac PET images. We present a method for MR-based cardiac and respiratory motion correction of cardiac PET data and evaluate its impact on estimation of activity and kinetic parameters in human subjects. Three healthy subjects underwent simultaneous dynamic 18F-FDG PET and MRI on a hybrid PET/MR scanner. A cardiorespiratory motion field was determined for each subject using navigator, tagging and golden-angle radial MR acquisitions. Acquired coincidence events were binned into cardiac and respiratory phases using electrocardiogram and list mode-driven signals, respectively. Dynamic PET images were reconstructed with MR-based motion correction (MC) and without motion correction (NMC). Parametric images of 18F-FDG consumption rates (Ki) were estimated using Patlak's method for both MC and NMC images. MC alleviated motion artifacts in PET images, resulting in improved spatial resolution, improved recovery of activity in the myocardium wall and reduced spillover from the myocardium to the left ventricle cavity. Significantly higher myocardium contrast-to-noise ratio and lower apparent wall thickness were obtained in MC versus NMC images. Likewise, parametric images of Ki calculated with MC data had improved spatial resolution as compared to those obtained with NMC. Consistent with an increase in reconstructed activity concentration in the frames used during kinetic analyses, MC led to the estimation of higher Ki values almost everywhere in the myocardium, with up to 18% increase (mean across subjects) in the septum as compared to NMC. This study shows that MR-based motion correction of cardiac PET results in improved image quality that can benefit both static and dynamic studies.
Collapse
|
32
|
Zhou JR, Zhang X, Zhao YL, Yang JF, Zhang JP, Cao XY, Lu Y, Liu DY, Lyu FY, Ouyang J, Lu PH. [Clinical characteristics and prognosis of 34 cases of acute myeloid leukemia with FLT3 internal tandem duplication and MLL gene rearrangement]. ZHONGHUA XUE YE XUE ZA ZHI = ZHONGHUA XUEYEXUE ZAZHI 2019; 39:751-756. [PMID: 30369187 PMCID: PMC7342257 DOI: 10.3760/cma.j.issn.0253-2727.2018.09.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
目的 探讨同时伴FLT3-ITD突变及MLL基因异常的急性髓系白血病(AML)患者的临床特征及转归。 方法 回顾性分析34例同时伴FLT3-ITD突变及MLL基因异常的AML患者的临床资料,比较化疗、化疗加靶向药物治疗及allo-HSCT的疗效及影响因素。 结果 34例同时伴FLT3-ITD突变及MLL基因异常的AML患者占同期住院AML患者的2.02%。入院时WBC>30×109/L的患者占63.6%,其中WBC>50×109/L者占39.4%。FAB亚型中以M5比例最高,占35.3%,染色体核型异常者达63.6%,其中复杂异常占12.1%。34例患者中仅有FLT3-ITD及MLL基因异常(双基因异常)者11例(32.4%),具FLT3及MLL以外的1种及1种以上的基因异常(多基因异常)者23例(67.6%)。34例患者2个疗程完全缓解(CR)率为29.4%,7例(20.6%)化疗≥3个疗程后CR,CR患者的早期复发率为52.9%。WBC>50×109/L以及多基因异常的患者2个疗程CR率较低(7.7%、5.4%),其中具有3种以上基因异常的患者无一例CR。34例患者2年总生存(OS)率为28.8%(95%CI 13.5%~46.0%),2年无病生存(DFS)率为27.1%(95% CI 12.5%~44.0%)。18例仅使用化疗或化疗加靶向药物治疗的患者,17例在2年内死亡,1例放弃治疗后失访。接受allo-HSCT治疗的患者3年OS率为43.4%(95%CI 13.7%~70.4%),3年DFS率为42.7%(95% CI 13.4%~69.7%)。 结论 同时伴FLT3-ITD突变及MLL基因异常的AML患者FAB分型以M5多见,常伴高白细胞血症、细胞遗传学异常及多基因异常。患者化疗缓解率低,早期复发率高,长期生存率低。高白细胞血症、多基因异常可能是此类患者疗效差的重要原因,allo-HSCT可改善患者的转归。
Collapse
|
33
|
Sun AN, Tian XP, Cao XS, Ouyang J, Gu J, Xu KL, Yu K, Zeng QS, Sun ZM, Chen GA, Gao SJ, Zhou J, Wang JH, Yang LH, Luo JM, Zhang M, Guo XH, Wang XM, Zhang X, Shi KQ, Sun H, Ding XM, Hu JD, Zheng RJ, Zhao HG, Hou M, Wang X, Chen FP, Zhu Y, Liu H, Huang DP, Liao AJ, Ma LM, Su LP, Liu L, Zhou ZP, Huang XB, Sun XM, Wu DP. [Efficacy and safety of IA regimen containing different doses of idarubicin in de-novo acute myeloid leukemia for adult patients]. ZHONGHUA XUE YE XUE ZA ZHI = ZHONGHUA XUEYEXUE ZAZHI 2019; 38:1017-1023. [PMID: 29365393 PMCID: PMC7342198 DOI: 10.3760/cma.j.issn.0253-2727.2017.12.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
目的 探讨含不同剂量去甲氧柔红霉素(IDA 8、10、12 mg/m2)的IA方案诱导治疗成人初发急性髓系白血病(AML)(非急性早幼粒细胞白血病)的临床疗效和安全性。 方法 采用多中心、单盲、非随机、临床对照研究,纳入2011年5月至2015年3月苏州大学附属第一医院及其他36家单位收治的1 215例成人初发AML患者,根据诱导化疗方案中IDA的剂量对患者进行分组,分析不同剂量IDA联合阿糖胞苷(100 mg/m2)组成的IA方案在成人初发AML诱导治疗中的完全缓解(CR)率、血液学及非血液学不良事件。 结果 可纳入缓解率分析的AML患者共1 207例,IDA 8 mg/m2、10 mg/m2和12 mg/m2组的CR率分别为73.6%(215/292)、84.1%(662/787)和86.7%(111/128),差异有统计学意义(P<0.001);以IDA 8 mg/m2组为参照组,在调整了年龄、骨髓原始细胞比例、FAB分型、危险度分层后,IDA 10 mg/m2和IDA 12 mg/m2为影响患者CR的有利因素[OR=0.49(95% CI 0.34~0.70),P<0.001;OR=0.36(95%CI 0.18~0.71),P=0.003]。在中、低危组中三组CR率分别为76.5%(163/213)、86.9%(506/582)和86.1%(68/79),差异有统计学意义(P=0.007);在调整了年龄、骨髓原始细胞比例、FAB分型因素后,IDA 10 mg/m2为影响患者CR的有利因素[OR=0.47(95% CI 0.31~0.71),P<0.001]。在高危组中,三组CR率分别为50.0%(18/36)、60.6%(43/71)和81.8%(18/22),差异无统计学意义(P=0.089),但在调整了年龄、骨髓原始细胞比例、FAB分型因素后,IDA 12 mg/m2为影响患者CR的有利因素[OR=0.22(95% CI 0.06~0.80),P=0.022]。8 mg/m2、10 mg/m2和12 mg/m2组中性粒细胞≤0.5×109/L的中位持续时间分别为14(11~18)、15(11~20)和18(14~22)d,差异有统计学意义(P=0.012);三组PLT≤20×109/L的中位持续时间分别为14(7~17)、15(11~20)和17(15~21)d,差异有统计学意义(P=0.001);三组肺部感染发生率分别为9.8%、13.5%和25.2%,差异有统计学意义(P<0.001)。 结论 在中国成人(18~60岁)初发AML中,建议中、低危组患者采用含IDA 10 mg/m2的IA方案进行诱导治疗;而高危组AML建议选择含IDA 12 mg/m2的IA方案进行诱导治疗。
Collapse
|
34
|
Xu YY, Ouyang J, Zhou M, Xu Y, Li P, Shao XY, Chen B, Zhou RF. [A case report of Kasabach-Merritt syndrome treated with vindesine sulfate]. ZHONGHUA NEI KE ZA ZHI 2019; 58:143-145. [PMID: 30704202 DOI: 10.3760/cma.j.issn.0578-1426.2019.02.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
|
35
|
Zhu L, Jin F, Zhu YQ, Wang JC, Dong KF, Mo WQ, Song JL, Ouyang J. Giant Magneto-Impedance (GMI) Effect in Single-Layer Soft Magnetic Film Under Stress. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY 2018; 18:8195-8200. [PMID: 30189937 DOI: 10.1166/jnn.2018.15799] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
The stress-induced magnetic anisotropy can significantly affect giant magneto-impedance (GMI) effect of the soft magnetic film. This paper is devoted to the GMI effect of the single layer soft magnetic film implied without and with a stress. By simulating a physical model with MATLAB and COMSOL software, the impedance expression of the single layer soft magnetic film and the relation between external magnetic field and magnetic permeability are deduced. We observed that, without a stress, the sensitive region increased firstly and then decreased with the increasing of the excitation current frequency from 1 MHz to 200 MHz. While the film was subjected to the stress in the direction of the current with one end stressed, the stress on the film was gradually reduced from stressed end to free end. Also, the impedance change rate of the film changed when the stress was added, which is similar to the effect of adding a bias magnetic field on the film. More importantly, the addition of stress σ can induce the bias of the GMI measurement range and improve its sensitivity near zero magnetic fields. This may provide a new way for designing a GMI sensor with higher sensitivity and adjustable measurement range.
Collapse
|
36
|
Abstract
Myocardial perfusion imaging (MPI) using rest/stress single photon emission computed tomography (SPECT) allows non-invasive assessment of reversible cardiac perfusion defects. Conventionally, reversible defects are identified using a difference image, called reversible map, obtained by subtracting the stress image from the rest image after registration and normalization of the two images. The identification of reversible defects using the conventional subtraction method is however limited by noise. We propose to jointly reconstruct rest and stress projection data to directly obtain the reversible map in a single reconstruction framework to improve the detectability of reversible defects. To evaluate the performance of the proposed method, we performed phantom studies to mimic reversible defects with different levels of severity and doses. As compared to the conventional subtraction method, the joint method yielded reversible maps with much lower noise and improved defect detectability. At a normal clinical dose level, the joint method improved the signal to noise ratio (SNR) of defect contrast in reversible maps from 13.2 to 66.4, 9.7 to 35.0, 6.1 to 13.2, and 3.1 to 6.5, for defect to normal myocardium concentration ratios of 0%, 25%, 50%, and 75%, respectively. The SNRs obtained using the joint method were improved from 6.1 to 13.2, 3.9 to 9.4, 3.0 to 8.0, and 2.1 to 7.1, for 100%, 75%, 50%, and 25% of the normal clinical dose as compared to the conventional subtraction method. To access clinical feasibility, we applied the joint method to a rest/stress SPECT MPI patient study. The joint method yielded a reversible map with much lower noise, translating into a much higher defect detectability as compared to the conventional subtraction method. Our results indicate that the joint method has the potential to improve radiologists' performance for assessing defects in rest/stress SPECT MPI. In addition, the joint method can be used to reduce dose or imaging time.
Collapse
|
37
|
Qian L, Jiang C, Sun P, Xu D, Wang Y, Fu M, Zhong S, Ouyang J. A comparison of the biomechanical stability of pedicle-lengthening screws and traditional pedicle screws: an in vitro instant and fatigue-resistant pull-out test. Bone Joint J 2018; 100-B:516-521. [PMID: 29629595 DOI: 10.1302/0301-620x.100b4.bjj-2017-0877.r1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Aims The aim of this study was to compare the peak pull-out force (PPF) of pedicle-lengthening screws (PLS) and traditional pedicle screws (TPS) using instant and cyclic fatigue testing. Materials and Methods A total of 60 lumbar vertebrae were divided into six groups: PLS submitted to instant pull-out and fatigue-resistance testing (groups A1 and A2, respectively), TPS submitted to instant pull-out and fatigue-resistance testing (groups B1 and B2, respectively) and PLS augmented with 2 ml polymethylmethacrylate, submitted to instant pull-out and fatigue-resistance testing (groups C1 and C2, respectively). The PPF and normalized PPF (PPFn) for bone mineral density (BMD) were compared within and between all groups. Results In all groups, BMD was significantly correlated with PPF (r = 0.83, p < 0.001). The PPFn in A1 was significantly less than in B1 (p = 0.006) and C1 (p = 0.002). The PPFn of A2 was significantly less than in B2 (p < 0.001) and C2 (p < 0.001). The PPFn in A1, B1, and C1 was significantly greater than in A2 (p = 0.002), B2 (p = 0.027), and C2 (p = 0.003). There were no significant differences in PPFn between B1 and C1, or between B2 and C2. Conclusion Pedicle lengthening screws with cement augmentation can provide the same fixation stability as traditional pedicle screws and may be a viable clinical option. Cite this article: Bone Joint J 2018;100-B:516-21.
Collapse
|
38
|
Guo R, Petibon Y, Ma Y, El Fakhri G, Ying K, Ouyang J. MR-based motion correction for cardiac PET parametric imaging: a simulation study. EJNMMI Phys 2018; 5:3. [PMID: 29388075 PMCID: PMC5792384 DOI: 10.1186/s40658-017-0200-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2017] [Accepted: 12/04/2017] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND Both cardiac and respiratory motions bias the kinetic parameters measured by dynamic PET. The aim of this study was to perform a realistic positron emission tomography-magnetic resonance (PET-MR) simulation study using 4D XCAT to evaluate the impact of MR-based motion correction on the estimation of PET myocardial kinetic parameters using PET-MR. Dynamic activity distributions were obtained based on a one-tissue compartment model with realistic kinetic parameters and an arterial input function. Realistic proton density/T1/T2 values were also defined for the MRI simulation. Two types of motion patterns, cardiac motion only (CM) and both cardiac and respiratory motions (CRM), were generated. PET sinograms were obtained by the projection of the activity distributions. PET image for each time frame was obtained using static (ST), gated (GA), non-motion-corrected (NMC), and motion-corrected (MC) methods. Voxel-wise unweighted least squares fitting of the dynamic PET data was then performed to obtain K1 values for each study. For each study, the mean and standard deviation of K1 values were computed for four regions of interest in the myocardium across 25 noise realizations. RESULTS Both cardiac and respiratory motions introduce blurring in the PET parametric images if the motion is not corrected. Conventional cardiac gating is limited by high noise level on parametric images. Dual cardiac and respiratory gating further increases the noise level. In contrast to GA, the MR-based MC method reduces motion blurring in parametric images without increasing noise level. It also improves the myocardial defect delineation as compared to NMC method. Finally, the MR-based MC method yields lower bias and variance in K1 values than NMC and GA, respectively. The reductions of K1 bias by MR-based MC are 7.7, 5.1, 15.7, and 29.9% in four selected 0.18-mL myocardial regions of interest, respectively, as compared to NMC for CRM. MR-based MC yields 85.9, 75.3, 71.8, and 95.2% less K1 standard deviation in the four regions, respectively, as compared to GA for CRM. CONCLUSIONS This simulation study suggests that the MR-based motion-correction method using PET-MR greatly reduces motion blurring on parametric images and yields less K1 bias without increasing noise level.
Collapse
|
39
|
Zhou WN, Ouyang J, Wang ZH, Wang XY, Suo YR, Zhang Z, Wang HL. Target-guided isolation and purification of antioxidants from Elsholtzia densa Benth. var. densa by DPPH antioxidant assay and dual-mode HSCCC. ACTA CHROMATOGR 2017. [DOI: 10.1556/1326.2017.00192] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
40
|
Wan YK, Sang W, Chen B, Yang YG, Zhang LQ, Sun AN, Liu YJ, Xu Y, Cai YP, Wang CB, Shen YF, Jiang YW, Zhang XY, Xu W, Hong M, Chen T, Xu RR, Li F, Xu YL, Xue Y, Lu YL, He ZM, Dong WM, Chen Z, Ji MH, Yang YY, Zhai LJ, Zhao Y, Wu GQ, Ding JH, Cheng J, Cai WB, Sun YM, Ouyang J. [Distribution and drug resistance of pathogens at hematology department of Jiangsu Province from 2014 to 2015: results from a multicenter, retrospective study]. ZHONGHUA XUE YE XUE ZA ZHI = ZHONGHUA XUEYEXUE ZAZHI 2017; 38:602-606. [PMID: 28810329 PMCID: PMC7342276 DOI: 10.3760/cma.j.issn.0253-2727.2017.07.010] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Download PDF] [Subscribe] [Scholar Register] [Received: 11/12/2016] [Indexed: 11/05/2022]
Abstract
Objective: To describe the distribution and drug resistance of pathogens at hematology department of Jiangsu Province from 2014 to 2015 to provide reference for empirical anti-infection treatment. Methods: Pathogens were from hematology department of 26 tertiary hospitals in Jiangsu Province from 2014 to 2015. Antimicrobial susceptibility testing was carried out according to a unified protocol using Kirby-Bauer method or agar dilution method. Collection of drug susceptibility results and corresponding patient data were analyzed. Results: The separated pathogens amounted to 4 306. Gram-negative bacteria accounted for 64.26%, while the proportions of gram-positive bacteria and funguses were 26.99% and 8.75% respectively. Common gram-negative bacteria were Escherichia coli (20.48%) , Klebsiella pneumonia (15.40%) , Pseudomonas aeruginosa (8.50%) , Acinetobacter baumannii (5.04%) and Stenotropho-monas maltophilia (3.41%) respectively. CRE amounted to 123 (6.68%) . Common gram-positive bacteria were Staphylococcus aureus (4.92%) , Staphylococcus hominis (4.88%) and Staphylococcus epidermidis (4.71%) respectively. Candida albicans were the main fungus which accounted for 5.43%. The rates of Escherichia coli and Klebsiella pneumonia resistant to carbapenems were 3.5%-6.1% and 5.0%-6.3% respectively. The rates of Pseudomonas aeruginosa resistant to tobramycin and amikacin were 3.2% and 3.3% respectively. The resistant rates of Acinetobacter baumannii towards tobramycin and cefoperazone/sulbactam were both 19.2%. The rates of Stenotrophomonas maltophilia resistant to minocycline and sulfamethoxazole were 3.5% and 9.3% respectively. The rates of Staphylococcus aureus, Enterococcus faecium and Enterococcus faecalis resistant wards vancomycin were 0, 6.4% and 1.4% respectively; also, the rates of them resistant to linezolid were 1.2%, 0 and 1.6% respectively; in addition, the rates of them resistant to teicoplanin were 2.8%, 14.3% and 8.0% respectively. Furthermore, MRSA accounted for 39.15% (83/212) . Conclusions: Pathogens were mainly gram-negative bacteria. CRE accounted for 6.68%. The rates of Escherichia coli and Klebsiella pneumonia resistant to carbapenems were lower compared with other antibacterial agents. The rates of gram-positive bacteria resistant to vancomycin, linezolid and teicoplanin were still low. MRSA accounted for 39.15%.
Collapse
|
41
|
Zhang H, Wang H, Zeng C, Yan B, Ouyang J, Liu X, Sun Q, Zhao C, Fang H, Pan J, Xie D, Yang J, Zhang T, Bai X, Cai D. mTORC1 activation downregulates FGFR3 and PTH/PTHrP receptor in articular chondrocytes to initiate osteoarthritis. Osteoarthritis Cartilage 2017; 25:952-963. [PMID: 28043938 DOI: 10.1016/j.joca.2016.12.024] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/10/2016] [Revised: 11/09/2016] [Accepted: 12/21/2016] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Articular chondrocyte activation, involving aberrant proliferation and prehypertrophic differentiation, is essential for osteoarthritis (OA) initiation and progression. Disruption of mechanistic target of rapamycin complex 1 (mTORC1) promotes chondrocyte autophagy and survival, and decreases the severity of experimental OA. However, the role of cartilage mTORC1 activation in OA initiation is unknown. In this study, we elucidated the specific role of mTORC1 activation in OA initiation, and identify the underlying mechanisms. METHOD Expression of mTORC1 in articular cartilage of OA patients and OA mice was assessed by immunostaining. Cartilage-specific tuberous sclerosis complex 1 (Tsc1, mTORC1 upstream inhibitor) knockout (TSC1CKO) and inducible Tsc1 KO (TSC1CKOER) mice were generated. The functional effects of mTORC1 in OA initiation and development on its downstream targets were examined by immunostaining, western blotting and qPCR. RESULTS Articular chondrocyte mTORC1 was activated in early-stage OA and in aged mice. TSC1CKO mice exhibited spontaneous OA, and TSC1CKOER mice (from 2 months) exhibited accelerated age-related and DMM-induced OA phenotypes, with aberrant chondrocyte proliferation and hypertrophic differentiation. This was associated with hyperactivation of mTORC1 and dramatic downregulation of FGFR3 and PPR, two receptors critical for preventing chondrocyte proliferation and differentiation. Rapamycin treatment reversed these phenotypes in KO mice. Furthermore, in vitro rescue experiments demonstrated that p73 and ERK1/2 may mediate the negative regulation of FGFR3 and PPR by mTORC1. CONCLUSION mTORC1 activation stimulates articular chondrocyte proliferation and differentiation to initiate OA, in part by downregulating FGFR3 and PPR.
Collapse
|
42
|
Petibon Y, Rakvongthai Y, Fakhri GE, Ouyang J. Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in vivo studies. Phys Med Biol 2017; 62:3539-3565. [PMID: 28379843 PMCID: PMC5739089 DOI: 10.1088/1361-6560/aa6394] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Dynamic PET myocardial perfusion imaging (MPI) used in conjunction with tracer kinetic modeling enables the quantification of absolute myocardial blood flow (MBF). However, MBF maps computed using the traditional indirect method (i.e. post-reconstruction voxel-wise fitting of kinetic model to PET time-activity-curves-TACs) suffer from poor signal-to-noise ratio (SNR). Direct reconstruction of kinetic parameters from raw PET projection data has been shown to offer parametric images with higher SNR compared to the indirect method. The aim of this study was to extend and evaluate the performance of a direct parametric reconstruction method using in vivo dynamic PET MPI data for the purpose of quantifying MBF. Dynamic PET MPI studies were performed on two healthy pigs using a Siemens Biograph mMR scanner. List-mode PET data for each animal were acquired following a bolus injection of ~7-8 mCi of 18F-flurpiridaz, a myocardial perfusion agent. Fully-3D dynamic PET sinograms were obtained by sorting the coincidence events into 16 temporal frames covering ~5 min after radiotracer administration. Additionally, eight independent noise realizations of both scans-each containing 1/8th of the total number of events-were generated from the original list-mode data. Dynamic sinograms were then used to compute parametric maps using the conventional indirect method and the proposed direct method. For both methods, a one-tissue compartment model accounting for spillover from the left and right ventricle blood-pools was used to describe the kinetics of 18F-flurpiridaz. An image-derived arterial input function obtained from a TAC taken in the left ventricle cavity was used for tracer kinetic analysis. For the indirect method, frame-by-frame images were estimated using two fully-3D reconstruction techniques: the standard ordered subset expectation maximization (OSEM) reconstruction algorithm on one side, and the one-step late maximum a posteriori (OSL-MAP) algorithm on the other side, which incorporates a quadratic penalty function. The parametric images were then calculated using voxel-wise weighted least-square fitting of the reconstructed myocardial PET TACs. For the direct method, parametric images were estimated directly from the dynamic PET sinograms using a maximum a posteriori (MAP) parametric reconstruction algorithm which optimizes an objective function comprised of the Poisson log-likelihood term, the kinetic model and a quadratic penalty function. Maximization of the objective function with respect to each set of parameters was achieved using a preconditioned conjugate gradient algorithm with a specifically developed pre-conditioner. The performance of the direct method was evaluated by comparing voxel- and segment-wise estimates of [Formula: see text], the tracer transport rate (ml · min-1 · ml-1), to those obtained using the indirect method applied to both OSEM and OSL-MAP dynamic reconstructions. The proposed direct reconstruction method produced [Formula: see text] maps with visibly lower noise than the indirect method based on OSEM and OSL-MAP reconstructions. At normal count levels, the direct method was shown to outperform the indirect method based on OSL-MAP in the sense that at matched level of bias, reduced regional noise levels were obtained. At lower count levels, the direct method produced [Formula: see text] estimates with significantly lower standard deviation across noise realizations than the indirect method based on OSL-MAP at matched bias level. In all cases, the direct method yielded lower noise and standard deviation than the indirect method based on OSEM. Overall, the proposed direct reconstruction offered a better bias-variance tradeoff than the indirect method applied to either OSEM and OSL-MAP. Direct parametric reconstruction as applied to in vivo dynamic PET MPI data is therefore a promising method for producing MBF maps with lower variance.
Collapse
|
43
|
Rakvongthai Y, Fahey F, Borvorntanajanya K, Tepmongkol S, Vutrapongwatana U, Zukotynski K, El Fakhri G, Ouyang J. Joint reconstruction of Ictal/inter-ictal SPECT data for improved epileptic foci localization. Med Phys 2017; 44:1437-1444. [PMID: 28211105 DOI: 10.1002/mp.12167] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2016] [Revised: 02/08/2017] [Accepted: 02/09/2017] [Indexed: 11/11/2022] Open
Abstract
PURPOSE To improve the performance for localizing epileptic foci, we have developed a joint ictal/inter-ictal SPECT reconstruction method in which ictal and inter-ictal SPECT projections are simultaneously reconstructed to obtain the differential image. METHODS We have developed a SPECT reconstruction method that jointly reconstructs ictal and inter-ictal SPECT projection data. We performed both phantom and patient studies to evaluate the performance of our joint method for epileptic foci localization as compared with the conventional subtraction method in which the differential image is obtained by subtracting the inter-ictal image from the co-registered ictal image. Two low-noise SPECT projection datasets were acquired using 99m Tc and a Hoffman head phantom at two different positions and orientations. At one of the two phantom locations, a low-noise dataset was also acquired using a 99m Tc-filled 3.3-cm sphere with a cold attenuation background identical to the Hoffman phantom. These three datasets were combined and scaled to mimic low-noise clinical ictal (three different lesion-to-background contrast levels: 1.25, 1.55, and 1.70) and inter-ictal scans. For each low-noise dataset, 25 noise realizations were generated by adding Poisson noise to the projections. The mean and standard deviation (SD) of lesion contrast in the differential images were computed using both the conventional subtraction and our joint methods. We also applied both methods to the 35 epileptic patient datasets. Each differential image was presented to two nuclear medicine physicians to localize a lesion and specify a confidence level. The readers' data were analyzed to obtain the localized-response receiver operating characteristic (LROC) curves for both the subtraction and joint methods. RESULTS For the phantom study, the difference between the mean lesion contrast in the differential images obtained using the conventional subtraction versus our joint method decreases as the iteration number increases. Compared with the conventional subtraction approach, the SD reduction of lesion contrast at the 10th iteration using our joint method ranges from 54.7% to 68.2% (P < 0.0005), and 33.8% to 47.9% (P < 0.05) for 2 and 4 million total inter-ictal counts, respectively. In the patient study, our joint method increases the area under LROC from 0.24 to 0.34 and from 0.15 to 0.20 for the first and second reader, respectively. We have demonstrated improved performance of our method as compared to the standard subtraction method currently used in clinical practice. CONCLUSION The proposed joint ictal/inter-ictal reconstruction method yields better performance for epileptic foci localization than the conventional subtraction method.
Collapse
|
44
|
Fu M, Ye Q, Jiang C, Qian L, Xu D, Wang Y, Sun P, Ouyang J. The segment-dependent changes in lumbar intervertebral space height during flexion-extension motion. Bone Joint Res 2017; 6:245-252. [PMID: 28450317 PMCID: PMC5415903 DOI: 10.1302/2046-3758.64.bjr-2016-0245.r1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/20/2016] [Accepted: 02/07/2017] [Indexed: 11/09/2022] Open
Abstract
Objectives Many studies have investigated the kinematics of the lumbar spine and the morphological features of the lumbar discs. However, the segment-dependent immediate changes of the lumbar intervertebral space height during flexion-extension motion are still unclear. This study examined the changes of intervertebral space height during flexion-extension motion of lumbar specimens. Methods First, we validated the accuracy and repeatability of a custom-made mechanical loading equipment set-up. Eight lumbar specimens underwent CT scanning in flexion, neural, and extension positions by using the equipment set-up. The changes in the disc height and distance between adjacent two pedicle screw entry points (DASEP) of the posterior approach at different lumbar levels (L3/4, L4/5 and L5/S1) were examined on three-dimensional lumbar models, which were reconstructed from the CT images. Results All the vertebral motion segments (L3/4, L4/5 and L5/S1) had greater changes in disc height and DASEP from neutral to flexion than from neutral to extension. The change in anterior disc height gradually increased from upper to lower levels, from neutral to flexion. The changes in anterior and posterior disc heights were similar at the L4/5 level from neutral to extension, but the changes in anterior disc height were significantly greater than those in posterior disc height at the L3/4 and L5/S1 levels, from neutral to extension. Conclusions The lumbar motion segment showed level-specific changes in disc height and DASEP. The data may be helpful in understanding the physiologic dynamic characteristics of the lumbar spine and in optimising the parameters of lumbar surgical instruments. Cite this article: M. Fu, Q. Ye, C. Jiang, L. Qian, D. Xu, Y. Wang, P. Sun, J. Ouyang. The segment-dependent changes in lumbar intervertebral space height during flexion-extension motion. Bone Joint Res 2017;6:245–252. DOI: 10.1302/2046-3758.64.BJR-2016-0245.R1.
Collapse
|
45
|
Burman J, Kirgizov K, Carlson K, Badoglio M, Mancardi GL, De Luca G, Casanova B, Ouyang J, Bembeeva R, Haas J, Bader P, Snowden J, Farge D. Autologous hematopoietic stem cell transplantation for pediatric multiple sclerosis: a registry-based study of the Autoimmune Diseases Working Party (ADWP) and Pediatric Diseases Working Party (PDWP) of the European Society for Blood and Marrow Transplantation (EBMT). Bone Marrow Transplant 2017; 52:1133-1137. [DOI: 10.1038/bmt.2017.40] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2016] [Revised: 12/14/2016] [Accepted: 01/27/2017] [Indexed: 11/09/2022]
|
46
|
Ouyang J, Hardy R, Brown M, Helliwell T, Gurnell M, Cuthbertson DJ. 11C-metomidate PET-CT scanning can identify aldosterone-producing adenomas after unsuccessful lateralisation with CT/MRI and adrenal venous sampling. J Hum Hypertens 2017; 31:483-484. [DOI: 10.1038/jhh.2017.9] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
47
|
Li G, Zhou D, Kan L, Wu Y, Fan J, Ouyang J. Competitive inhibition of phytic acid on enzymatic browning of chestnut (Castanea mollissima Blume). ACTA ALIMENTARIA 2017. [DOI: 10.1556/066.2017.46.1.13] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
48
|
Petibon Y, Guehl NJ, Reese TG, Ebrahimi B, Normandin MD, Shoup TM, Alpert NM, El Fakhri G, Ouyang J. Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR. Phys Med Biol 2017; 62:326-343. [PMID: 27997375 PMCID: PMC5241952 DOI: 10.1088/1361-6560/aa5087] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
PET is an established modality for myocardial perfusion imaging (MPI) which enables quantification of absolute myocardial blood flow (MBF) using dynamic imaging and kinetic modeling. However, heart motion and partial volume effects (PVE) significantly limit the spatial resolution and quantitative accuracy of PET MPI. Simultaneous PET-MR offers a solution to the motion problem in PET by enabling MR-based motion correction of PET data. The aim of this study was to develop a motion and PVE correction methodology for PET MPI using simultaneous PET-MR, and to assess its impact on both static and dynamic PET MPI using 18F-Flurpiridaz, a novel 18F-labeled perfusion tracer. Two dynamic 18F-Flurpiridaz MPI scans were performed on healthy pigs using a PET-MR scanner. Cardiac motion was tracked using a dedicated tagged-MRI (tMR) sequence. Motion fields were estimated using non-rigid registration of tMR images and used to calculate motion-dependent attenuation maps. Motion correction of PET data was achieved by incorporating tMR-based motion fields and motion-dependent attenuation coefficients into image reconstruction. Dynamic and static PET datasets were created for each scan. Each dataset was reconstructed as (i) Ungated, (ii) Gated (end-diastolic phase), and (iii) Motion-Corrected (MoCo), each without and with point spread function (PSF) modeling for PVE correction. Myocardium-to-blood concentration ratios (MBR) and apparent wall thickness were calculated to assess image quality for static MPI. For dynamic MPI, segment- and voxel-wise MBF values were estimated by non-linear fitting of a 2-tissue compartment model to tissue time-activity-curves. MoCo and Gating respectively decreased mean apparent wall thickness by 15.1% and 14.4% and increased MBR by 20.3% and 13.6% compared to Ungated images (P < 0.01). Combined motion and PSF correction (MoCo-PSF) yielded 30.9% (15.7%) lower wall thickness and 82.2% (20.5%) higher MBR compared to Ungated data reconstructed without (with) PSF modeling (P < 0.01). For dynamic PET, mean MBF across all segments were comparable for MoCo (0.72 ± 0.21 ml/min/ml) and Gating (0.69 ± 0.18 ml/min/ml). Ungated data yielded significantly lower mean MBF (0.59 ± 0.16 ml/min/ml). Mean MBF for MoCo-PSF was 0.80 ± 0.22 ml/min/ml, which was 37.9% (25.0%) higher than that obtained from Ungated data without (with) PSF correction (P < 0.01). The developed methodology holds promise to improve the image quality and sensitivity of PET MPI studies performed using PET-MR.
Collapse
|
49
|
Wang X, Zhang L, Sun A, Yang X, Sang W, Jiang Y, Cheng J, Wang J, Zhou M, Chen B, Ouyang J. Acinetobacter baumannii bacteraemia in patients with haematological malignancy: a multicentre retrospective study from the Infection Working Party of Jiangsu Society of Hematology. Eur J Clin Microbiol Infect Dis 2017; 36:1073-1081. [DOI: 10.1007/s10096-016-2895-2] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2016] [Accepted: 12/14/2016] [Indexed: 12/14/2022]
|
50
|
Zhu W, Ouyang J, Rakvongthai Y, Guehl NJ, Wooten DW, El Fakhri G, Normandin MD, Fan Y. A Bayesian spatial temporal mixtures approach to kinetic parametric images in dynamic positron emission tomography. Med Phys 2016; 43:1222-34. [PMID: 26936707 DOI: 10.1118/1.4941010] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Estimation of parametric maps is challenging for kinetic models in dynamic positron emission tomography. Since voxel kinetics tend to be spatially contiguous, the authors consider groups of homogeneous voxels together. The authors propose a novel algorithm to identify the groups and estimate kinetic parameters simultaneously. Uncertainty estimates for kinetic parameters are also obtained. METHODS Mixture models were used to fit the time activity curves. In order to borrow information from spatially nearby voxels, the Potts model was adopted. A spatial temporal model was built incorporating both spatial and temporal information in the data. Markov chain Monte Carlo was used to carry out parameter estimation. Evaluation and comparisons with existing methods were carried out on cardiac studies using both simulated data sets and a pig study data. One-compartment kinetic modeling was used, in which K1 is the parameter of interest, providing a measure of local perfusion. RESULTS Based on simulation experiments, the median standard deviation across all image voxels, of K1 estimates were 0, 0.13, and 0.16 for the proposed spatial mixture models (SMMs), standard curve fitting, and spatial K-means methods, respectively. The corresponding median mean squared biases for K1 were 0.04, 0.06, and 0.06 for abnormal region of interest (ROI); 0.03, 0.03, and 0.04 for normal ROI; and 0.007, 0.02, and 0.05 for the noise region. CONCLUSIONS SMM is a fully Bayesian algorithm which determines the optimal number of homogeneous voxel groups, voxel group membership, parameter estimation, and parameter uncertainty estimation simultaneously. The voxel membership can also be used for classification purposes. By borrowing information from spatially nearby voxels, SMM substantially reduces the variability of parameter estimates. In some ROIs, SMM also reduces mean squared bias.