51
|
Price DB, Bosnic-Anticevich S, Pavord ID, Roche N, Halpin DMG, Bjermer L, Usmani OS, Brusselle G, Ming SWY, Rastogi S. Association of elevated fractional exhaled nitric oxide concentration and blood eosinophil count with severe asthma exacerbations. Clin Transl Allergy 2019; 9:41. [PMID: 31452870 PMCID: PMC6702739 DOI: 10.1186/s13601-019-0282-7] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2019] [Accepted: 08/08/2019] [Indexed: 12/13/2022] Open
Abstract
Background Blood eosinophil count (BEC) and fractional exhaled nitric oxide (FeNO) concentration are established biomarkers in asthma, associated particularly with the risk of exacerbations. We evaluated the relationship of BEC and FeNO as complementary and independent biomarkers of severe asthma exacerbations. Methods This observational study included data from the Optimum Patient Care Research Database. Asthma patients (18–80 years) with valid continuous data for 1 year before FeNO reading, ≥ 1 inhaled corticosteroid prescription, and BEC recorded ≤ 5 years before FeNO reading were separated into cohorts. Categorisation 1 was based on the American Thoracic Society criteria for elevated FeNO concentration (high: ≥ 50 ppb; non-high: < 25 ppb) and BEC (high: ≥ 0.300 × 109 cells/L; non-high: < 0.300 × 109 cells/L). Categorisation 2 (FeNO concentration, high: ≥ 35 ppb; non-high: < 35 ppb) was based on prior research. Reference groups included patients with neither biomarker raised. Results In categorisation 1, patients with either high FeNO or high BEC (n = 200) had a numerically greater exacerbation rate (unadjusted rate ratio, 1.31 [95% confidence interval: 0.97, 1.76]) compared with patients in the reference group. Combination of high FeNO and high BEC (n = 27) resulted in a significantly greater exacerbation rate (3.67 [1.49, 9.04]). Similarly, for categorisation 2, when both biomarkers were raised (n = 53), a significantly greater exacerbation rate was observed (1.72 [1.00, 2.93]). Conclusion The combination of high FeNO and high BEC was associated with significantly increased severe exacerbation rates in the year preceding FeNO reading, suggesting that combining FeNO and BEC measurements in primary care may identify asthma patients at risk of exacerbations. Electronic supplementary material The online version of this article (10.1186/s13601-019-0282-7) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- David B Price
- 1Observational and Pragmatic Research Institute, Singapore, Singapore.,2Academic Primary Care, Division of Applied Health Sciences, University of Aberdeen, Polwarth Building, Foresterhill, Aberdeen, AB25 2ZD UK
| | | | - Ian D Pavord
- 4Oxford NIHR Respiratory Biomedical Research Centre, Nuffield Department of Medicine, University of Oxford, Oxford, UK
| | | | | | | | | | | | | | - Sarang Rastogi
- 10Global Medical Affairs, AstraZeneca, Gaithersburg, USA
| |
Collapse
|
52
|
Dolovich MB, Kuttler A, Dimke TJ, Usmani OS. Biophysical model to predict lung delivery from a dual bronchodilator dry-powder inhaler. Int J Pharm X 2019; 1:100018. [PMID: 31517283 PMCID: PMC6733285 DOI: 10.1016/j.ijpx.2019.100018] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/06/2019] [Revised: 05/24/2019] [Accepted: 05/27/2019] [Indexed: 11/30/2022]
Abstract
A biophysical lung model was designed to predict inhaled drug deposition in patients with obstructive airway disease, and quantitatively investigate sources of deposition variability. Different mouth-throat anatomies at varying simulated inhalation flows were used to calculate the lung dose of indacaterol/glycopyrronium [IND/GLY] 110/50 µg (QVA149) from the dry-powder inhaler Breezhaler®. Sources of variability in lung dose were studied using computational fluid dynamics, supported by aerosol particle sizing measurements, particle image velocimetry and computed tomography. Anatomical differences in mouth-throat geometries were identified as a major source of inter-subject variability in lung deposition. Lung dose was similar across inhalation flows of 30–120 L/min with a slight drop in calculated delivery at high inspiratory flows. Delivery was relatively unaffected by inhaler inclination angle. The delivered lung dose of the fixed-dose combination IND/GLY matched well with corresponding monotherapy doses. This biophysical model indicates low extra-thoracic drug loss and consistent lung delivery of IND/GLY, independent of inhalation flows. This is an important finding for patients across various ages and lung disease severities. The model provides a quantitative, mechanistic simulation of inhaled therapies that could provide a test system for estimating drug delivery to the lung and complement traditional clinical studies.
Collapse
Key Words
- AIT, Alberta idealised throat
- APSD, aerodynamic particle size distribution
- CFD, computational fluid dynamics
- COPD, chronic obstructive pulmonary disease
- CT, computed tomography
- Chronic obstructive pulmonary disease
- Computational fluid dynamics
- DPI, dry powder inhaler
- Dry powder inhaler
- FDC, fixed-dose combination
- GLY, glycopyrronium
- HRCT, high-resolution computed tomography
- IFR, inspiratory flow rate
- IND, indacaterol
- Inhaler devices
- Lung deposition
- MMAD, mass median aerodynamic diameter
- NGI, Next Generation Impactor
- PIV, particle image velocimetry
- USP/Ph. Eur, European Union Pharmacopoeias
- pMDI, pressurised metered dose inhaler
Collapse
Affiliation(s)
- Myrna B Dolovich
- Department of Medicine, Division of Respirology, Faculty of Health Sciences, McMaster University, Hamilton, Ontario, Canada
| | | | | | - Omar S Usmani
- National Heart and Lung Institute, Imperial College London, London, UK
| |
Collapse
|
53
|
Abstract
Appropriate selection and correct use of inhalation devices is an integral component in the management of asthma and chronic obstructive pulmonary disease (COPD). It is well known that there are many challenges with the use of inhalers, and no one device suits all patients. Challenges can range from difficulties related to lung disease severity and pulmonary function to physical considerations, including manual dexterity and comorbidities such as arthritis. In terms of device selection and adherence, patient engagement and satisfaction are also important factors to consider. Furthermore, problems with inhaler use can be most evident in children and older patients. Here, we discuss aspects for consideration with commonly used devices, including nebulizers, pressurized metered-dose inhalers, dry powder inhalers, and the soft mist inhaler. As each inhaler offers varying technical properties, a tailored and personalized approach to the selection of the most appropriate device for the patient is highly recommended in order to increase the likelihood of achieving improved disease outcomes and enhance persistence with device adherence. Importantly, education and support is crucial, not only to enable patients to recognize the need for optimal disease management, but also to help them develop good inhaler technique. In addition, health care professionals should also aim to increase their knowledge of the devices they prescribe, and develop systems to ensure that they offer comprehensive support to patients in clinical practice. Considering these aspects, this review discusses potential strategies to help address the challenges of inhaler use in asthma and COPD.
Collapse
Affiliation(s)
- Omar S Usmani
- National Heart and Lung Institute (NHLI), Imperial College London and Royal Brompton Hospital, Airways Disease Section, London, UK,
| |
Collapse
|
54
|
Abstract
Inhalation therapy is one of the oldest approaches to the therapy of diseases of the respiratory tract. It is well recognised today that the most effective and safe means of treating the lungs is to deliver drugs directly to the airways. Surprisingly, the delivery of therapeutic aerosols has a rich history dating back more than 2,000 years to Ayurvedic medicine in India, but in many respects, the introduction of the first pressurised metered-dose inhaler (pMDI) in 1956 marked the beginning of the modern pharmaceutical aerosol industry. The pMDI was the first truly portable and convenient inhaler that effectively delivered drug to the lung and quickly gained widespread acceptance. Since 1956, the pharmaceutical aerosol industry has experienced dramatic growth. The signing of the Montreal Protocol in 1987 to reduce the use of CFCs as propellants for aerosols led to a surge in innovation that resulted in the diversification of inhaler technologies with significantly enhanced delivery efficiency, including modern pMDIs, dry powder inhalers and nebuliser systems. There is also great interest in tailoring particle size to deliver drugs to treat specific areas of the respiratory tract. One challenge that has been present since antiquity still exists, however, and that is ensuring that the patient has access to the medication and understands how to use it effectively. In this article, we will provide a summary of therapeutic aerosol delivery systems from ancient times to the present along with a look to the future.
Collapse
Affiliation(s)
- Federico Lavorini
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy.
| | | | - Omar S Usmani
- National Heart and Lung Institute, Imperial College London and Royal Brompton Hospital, London, UK
| |
Collapse
|
55
|
Usmani OS, Scullion J, Keeley D. Our planet or our patients-is the sky the limit for inhaler choice? Lancet Respir Med 2018; 7:11-13. [PMID: 30553845 DOI: 10.1016/s2213-2600(18)30497-1] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Subscribe] [Scholar Register] [Received: 10/14/2018] [Revised: 11/05/2018] [Accepted: 11/08/2018] [Indexed: 11/27/2022]
Affiliation(s)
- Omar S Usmani
- National Heart and Lung Institute, Imperial College London, London SW3 6LY, UK.
| | - Jane Scullion
- University Hospitals of Leicester NHS Trust, Leicester, UK
| | | |
Collapse
|
56
|
Abstract
Inhaled medication is the cornerstone in the treatment of patients across a spectrum of respiratory diseases including asthma and chronic obstructive pulmonary disease. The benefits of inhaled therapy have long been recognised but the most important innovations have occurred over the past 60 years, beginning with the invention of the pressurised metered dose inhaler. However, despite over 230 different device and drug combinations currently being available, disease control is far from perfect. Here we look at how innovation in inhaler design may improve treatments for respiratory diseases and how new formulations may lead to treatments for diseases beyond the lungs. We look at the three main areas where innovation in inhaled therapy is most likely to occur: 1) device engineering and design; 2) chemistry and formulations; and 3) digital technology associated with inhalers. Inhaler design has improved significantly but considerable challenges still remain in order to continually innovate and improve targeted drug delivery to the lungs. Healthcare professionals want see innovations that motivate their patients to achieve their goal of improving their health, through better adherence to treatment. Patients want devices that are easy to use and to see that their efforts are rewarded by improvements in their condition. KEY POINTS The dictionary definition of innovation is the introduction of new things, ideas or ways of doing something. We show how this definition can be applied to inhaled therapy.We take a look at the past to see what drove innovation in inhaler design and how this has led to the current devices.We look at the current drivers of innovation in engineering, chemistry and digital technology and predict how this may translate to new devices.Can innovation help the healthcare professional manage their patients better?What does the patient expect from innovation in their device? EDUCATIONAL AIMS To understand the importance of inhaled medication in the treatment of lung diseases.To understand how innovation has helped advance some of the devices patients use today from basic and inefficient designs.To understand the obstacles that prevent patients from receiving optimal treatment from their inhalers.To understand how innovation in inhaler design can lead to improved treatment for patients and widen the range of diseases that can be treated via the inhaled route.
Collapse
Affiliation(s)
- Martyn F. Biddiscombe
- National Heart and Lung Institute, Imperial College London and Royal Brompton Hospital, Airways Disease Section, London, UK
| | | |
Collapse
|
57
|
Satia I, Badri H, Lahousse L, Usmani OS, Spanevello A. Airways diseases: asthma, COPD and chronic cough highlights from the European Respiratory Society Annual Congress 2018. J Thorac Dis 2018; 10:S2992-S2997. [PMID: 30310687 PMCID: PMC6174133 DOI: 10.21037/jtd.2018.08.23] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2018] [Accepted: 07/19/2018] [Indexed: 11/06/2022]
Affiliation(s)
- Imran Satia
- Division of Respirology, Department of Medicine, McMaster University, Hamilton, Canada
- Division of Infection, Immunity and Respiratory Medicine, and Manchester Academic Health Science Centre, University of Manchester, Manchester, UK
| | - Huda Badri
- Division of Infection, Immunity and Respiratory Medicine, and Manchester Academic Health Science Centre, University of Manchester, Manchester, UK
| | - Lies Lahousse
- Pharmaceutical Care Unit, Department of Bioanalysis, Ghent University, Ghent, Belgium
| | - Omar S. Usmani
- National Heart and Lung Institute (NHLI), Imperial College London & Royal Brompton Hospital, London, UK
| | - Antonio Spanevello
- Department of Medicine and Surgery, University of Insubria, Varese, Italy
- Istituti Clinici Scientifici Maugeri IRCCS, Tradate, Italy
| |
Collapse
|
58
|
Usmani OS, Molimard M, Gaur V, Gogtay J, Singh GJP, Malhotra G, Derom E. Scientific Rationale for Determining the Bioequivalence of Inhaled Drugs. Clin Pharmacokinet 2018; 56:1139-1154. [PMID: 28290122 DOI: 10.1007/s40262-017-0524-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
In recent years, pathways for the development and approval of bioequivalent inhaled products have been established for regulated markets, including the European Union (EU), and a number of orally inhaled products (OIPs) have been approved in the EU solely on the basis of in vitro and pharmacokinetic data. This review describes how these development pathways are structured and their implications for the treatment of airway diseases such as asthma. The EU guidance follows a stepwise approach that includes in vitro criteria as the first step. If all in vitro criteria are not met, the second step is based on pharmacokinetic evaluations, which include assessments of lung and systemic bioavailability. If all pharmacokinetic criteria are not met, the third step is based on clinical endpoint studies. In this review, the scientific rationale of the European Medicines Agency guidance for the development of bioequivalent OIPs is reviewed with the focus on the development of bioequivalent OIPs in the EU. Indeed, we discuss the advantages and disadvantages of the weight-of-evidence and stepwise approaches. The evidence indicates that the EU guidance is robust and, unlike clinical endpoint studies, the pharmacokinetic studies are far more sensitive to measure the minor differences, i.e. deposition and absorption rates, in drug delivery from the test and reference products and, thus, should be best suited for assessing bioequivalence. The acceptance range of the 90% confidence intervals for pharmacokinetic bioequivalence (i.e. 80-125% for both the area under the plasma concentration-time curve and maximum plasma concentration) represent appropriately conservative margins for ensuring equivalent safety and efficacy of the test and reference products.
Collapse
Affiliation(s)
- Omar S Usmani
- Airways Disease Section, National Heart and Lung Institute, Imperial College London and Royal Brompton Hospital, Dovehouse Street, London, SW3 6LY, UK.
| | - Mathieu Molimard
- Department of Medical Pharmacology, CHU and University of Bordeaux, Bordeaux, France
| | - Vaibhav Gaur
- Global Medical Affairs, Cipla Ltd, Mumbai, India
| | | | | | | | - Eric Derom
- Department of Internal Medicine, Ghent University Hospital, Ghent, Belgium
| |
Collapse
|
59
|
Vincken W, Levy ML, Scullion J, Usmani OS, Dekhuijzen PNR, Corrigan CJ. Spacer devices for inhaled therapy: why use them, and how? ERJ Open Res 2018; 4:00065-2018. [PMID: 29928649 PMCID: PMC6004521 DOI: 10.1183/23120541.00065-2018] [Citation(s) in RCA: 53] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2018] [Accepted: 05/18/2018] [Indexed: 11/05/2022] Open
Abstract
We present an extensive review of the literature to date pertaining to the rationale for using a spacer/valved holding chamber (VHC) to deliver inhaled therapy from a pressurised, metered-dose inhaler, a discussion of how the properties of individual devices may vary according to their physical characteristics and materials of manufacture, the potential risks and benefits of ancillaries such as valves, and the evidence that they contribute tangibly to the delivery of therapy. We also reiterate practical recommendations for the correct usage and maintenance of spacers/VHCs, which we trust offer practical help and advice to patients and healthcare professionals alike.
Collapse
Affiliation(s)
- Walter Vincken
- Respiratory Division, University Hospital Brussels (UZ Brussel), Vrije Universiteit Brussel, Brussels, Belgium
| | | | | | | | | | - Chris J Corrigan
- Faculty of Life Sciences and Medicine, King's College London/Guy's and St Thomas's NHS Foundation Trust, London, UK
| |
Collapse
|
60
|
van Geffen WH, Hajian B, Vos W, De Backer J, Cahn A, Usmani OS, Van Holsbeke C, Pistolesi M, Kerstjens HA, De Backer W. Functional respiratory imaging: heterogeneity of acute exacerbations of COPD. Int J Chron Obstruct Pulmon Dis 2018; 13:1783-1792. [PMID: 29881268 PMCID: PMC5985851 DOI: 10.2147/copd.s152463] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/04/2022] Open
Abstract
Background Exacerbations of COPD are a major burden to patients, and yet little is understood about heterogeneity. It contributes to the current persistent one-size-fits-all treatment. To replace this treatment by more personalized, precision medicine, new insights are required. We assessed the heterogeneity of exacerbations by functional respiratory imaging (FRI) in 3-dimensional models of airways and lungs. Methods The trial was designed as a multicenter trial of patients with an acute exacerbation of COPD who were assessed by FRI, pulmonary function tests, and patient-reported outcomes, both in the acute stage and during resolution. Results Forty seven patients were assessed. FRI analyses showed significant improvements in hyperinflation (a decrease in total volume at functional residual capacity of −0.25±0.61 L, p≤0.01), airway volume at total lung capacity (+1.70±4.65 L, p=0.02), and airway resistance. As expected, these improvements correlated partially with changes in the quality of life and in conventional lung function test parameters. Patients with the same changes in pulmonary function differ in regional disease activity measured by FRI. Conclusion FRI is a useful tool to get a better insight into exacerbations of COPD, and significant improvements in its indices can be demonstrated from the acute phase to resolution even in relatively small groups. It clearly visualizes the marked variability within and between individuals in ventilation and resistance during exacerbations and is a tool for the assessment of the heterogeneity of COPD exacerbations.
Collapse
Affiliation(s)
- Wouter H van Geffen
- Department of Respiratory Medicine, Medical Centre Leeuwarden, Leeuwarden, the Netherlands.,Department of Pulmonary Diseases, University Medical Center Groningen, Groningen Research Institute for Asthma and COPD, University of Groningen, the Netherlands
| | - Bita Hajian
- Department of Pulmonary Diseases, Antwerp University Hospital, Antwerp, Belgium
| | - Wim Vos
- FLUIDDA nv, Kontich, Belgium
| | | | | | - Omar S Usmani
- Faculty of Medicine, National Heart & Lung Institute, Imperial College London, London, UK
| | | | - Massimo Pistolesi
- Department of Experimental and Clinical Medicine, Section of Respiratory Medicine, University of Florence, Florence, Italy
| | - Huib Am Kerstjens
- Department of Pulmonary Diseases, University Medical Center Groningen, Groningen Research Institute for Asthma and COPD, University of Groningen, the Netherlands
| | - Wilfried De Backer
- Department of Pulmonary Diseases, Antwerp University Hospital, Antwerp, Belgium
| |
Collapse
|
61
|
Hillyer EV, Price DB, Chrystyn H, Martin RJ, Israel E, van Aalderen WM, Papi A, Usmani OS, Roche N. Harmonizing the Nomenclature for Therapeutic Aerosol Particle Size: A Proposal. J Aerosol Med Pulm Drug Deliv 2018; 31:111-113. [DOI: 10.1089/jamp.2017.1396] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
- Elizabeth V. Hillyer
- Observational and Pragmatic Research Institute, Pte., Ltd., Singapore, Singapore
| | - David B. Price
- Observational and Pragmatic Research Institute, Pte., Ltd., Singapore, Singapore
- Academic Primary Care, University of Aberdeen, Aberdeen, United Kingdom
| | - Henry Chrystyn
- Observational and Pragmatic Research Institute, Pte., Ltd., Singapore, Singapore
- Inhalation Consultancy, Ltd., Leeds, United Kingdom
| | - Richard J. Martin
- Department of Medicine, National Jewish Health and University of Colorado Denver, Denver, Colorado
| | - Elliot Israel
- Pulmonary and Critical Care Division, Brigham and Women's Hospital and Harvard Medical School, Boston, Massachusetts
| | - Willem M.C. van Aalderen
- Department of Pediatric Respiratory Medicine and Allergy, Emma Children's Hospital AMC, Amsterdam, The Netherlands
| | - Alberto Papi
- Department of Medical Sciences, University of Ferrara, Ferrara, Italy
| | - Omar S. Usmani
- Airway Disease Section, National Heart and Lung Institute, Imperial College London, and Royal Brompton Hospital, London, United Kingdom
| | - Nicolas Roche
- University Paris Descartes (EA2511), Cochin Hospital Group (AP-HP), Paris, France
| | | |
Collapse
|
62
|
Bonini M, Usmani OS. Let research leave you breathless, not physical exercise! ERJ Open Res 2018; 4:00010-2018. [PMID: 29577039 PMCID: PMC5859680 DOI: 10.1183/23120541.00010-2018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2018] [Accepted: 01/27/2018] [Indexed: 11/26/2022] Open
Abstract
Regular physical activity is strongly recommended by healthcare systems worldwide and evidence-based guidelines and is one of the most effective approaches for preventing chronic inflammatory diseases and maintaining health status [1]. Indeed, extensive evidence exists on the beneficial effect of physical training and rehabilitation programmes in asthma [2]. Physical activity has been shown to improve quality of life, exercise capacity, pulmonary function and symptoms, as well as reduce airway inflammation and bronchial responsiveness in patients with asthma [3–5]. However, intense physical exercise may trigger airway narrowing by imposing a high demand on the respiratory system, requiring subjects to ventilate primarily through the mouth and by-pass the nasal filter, with a subsequent increased pulmonary exposure to inhalant allergens, pollutants, irritants and adverse (i.e. cold, dry) environmental conditions [6]. Such airway narrowing, which transiently occurs as a result of exercise, is defined as exercise-induced bronchoconstriction (EIB) [7]. Interestingly, in a 5-year prospective study, subjects who stopped training experienced an attenuation, or in some circumstances disappearance, of EIB, whereas bronchial responsiveness, exercise-induced respiratory symptoms and eosinophilic airway inflammation increased amongst those who continued strenuous physical exercise, regardless of the pharmacological treatment strategies [8]. Put into context, ongoing intense training appears to be a causative, and not just a concomitant, factor of airway inflammation and narrowing. Proper endotyping of EIB and precision medicine strategies would allow subjects to fully profit from the very beneficial effects of exercise, without incurring health risks or affecting performanceshttp://ow.ly/spjT30irzjX
Collapse
Affiliation(s)
- Matteo Bonini
- National Heart and Lung Institute (NHLI), Imperial College London & Royal Brompton Hospital, London, UK
| | - Omar S Usmani
- National Heart and Lung Institute (NHLI), Imperial College London & Royal Brompton Hospital, London, UK
| |
Collapse
|
63
|
Usmani OS, Biddiscombe MF, Yang S, Meah S, Oballa E, Simpson JK, Fahy WA, Marshall RP, Lukey PT, Maher TM. The topical study of inhaled drug (salbutamol) delivery in idiopathic pulmonary fibrosis. Respir Res 2018; 19:25. [PMID: 29409488 PMCID: PMC5801831 DOI: 10.1186/s12931-018-0732-0] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2017] [Accepted: 01/31/2018] [Indexed: 01/16/2023] Open
Abstract
Background Our aim was to investigate total and regional lung delivery of salbutamol in subjects with idiopathic pulmonary fibrosis (IPF). Methods The TOPICAL study was a 4-period, partially-randomised, controlled, crossover study to investigate four aerosolised approaches in IPF subjects. Nine subjects were randomised to receive 99mTechnetium-labelled monodisperse salbutamol (1.5 μm or 6 μm; periods 1 and 2). Subjects also received radio-labelled salbutamol using a polydisperse nebuliser (period 3) and unlabelled salbutamol (400 μg) using a polydisperse pressurized metered dose inhaler with volumatic spacer (pMDI; period 4). Results Small monodisperse particles (1.5 μm) achieved significantly better total lung deposition (TLD, mean % ± SD) than larger particles (6 μm), where polydisperse nebulisation was poor; (TLD, 64.93 ± 10.72; 50.46 ± 17.04; 8.19 ± 7.72, respectively). Small monodisperse particles (1.5 μm) achieved significantly better lung penetration (mean % ± SD) than larger particles (6 μm), and polydisperse nebulisation showed lung penetration similar to the small particles; PI (mean ± SD) 0.8 ± 0.16, 0.49 ± 0.21, and 0.73 ± 0.19, respectively. Higher dose-normalised plasma salbutamol levels were observed following monodisperse 1.5 μm and 6 μm particles, compared to polydisperse pMDI inhalation, while lowest plasma levels were observed following polydisperse nebulisation. Conclusion Our data is the first systematic investigation of inhaled drug delivery in fibrotic lung disease. We provide evidence that inhaled drugs can be optimised to reach the peripheral areas of the lung where active scarring occurs in IPF. Trial registration This trial was registered on clinicaltrials.gov (NCT01457261). Electronic supplementary material The online version of this article (10.1186/s12931-018-0732-0) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Omar S Usmani
- Airways Disease Section, National Heart and Lung Institute, Imperial College London and Royal Brompton Hospital, London, UK
| | - Martyn F Biddiscombe
- Airways Disease Section, National Heart and Lung Institute, Imperial College London and Royal Brompton Hospital, London, UK.,Nuclear Medicine Department, Royal Brompton Hospital, Sydney Street, London, UK
| | - Shuying Yang
- GlaxoSmithKline R&D, Clinical Pharmacology, Modelling and Simulation, Stockley Park, London, UK
| | - Sally Meah
- Airways Disease Section, National Heart and Lung Institute, Imperial College London and Royal Brompton Hospital, London, UK
| | - Eunice Oballa
- GlaxoSmithKline R&D, Fibrosis and Lung Injury Discovery Performance Unit, Stevenage, UK
| | - Juliet K Simpson
- GlaxoSmithKline R&D, Fibrosis and Lung Injury Discovery Performance Unit, Stevenage, UK
| | - William A Fahy
- GlaxoSmithKline R&D, Respiratory Discovery Medicine, Stockley Park, London, UK
| | - Richard P Marshall
- GlaxoSmithKline R&D, Fibrosis and Lung Injury Discovery Performance Unit, Stevenage, UK
| | - Pauline T Lukey
- GlaxoSmithKline R&D, Fibrosis and Lung Injury Discovery Performance Unit, Stevenage, UK
| | - Toby M Maher
- NIHR Respiratory Biomedical Research Unit, Royal Brompton Hospital, London, UK. .,Fibrosis Research Group, Inflammation, Repair & Development Section, National Heart and Lung Institute, Imperial College, Sir Alexander Fleming Building, London, SW7 2AZ, UK.
| |
Collapse
|
64
|
Taylor G, Warren S, Dwivedi S, Sommerville M, Mello L, Orevillo C, Maes A, Martin UJ, Usmani OS. Gamma scintigraphic pulmonary deposition study of glycopyrronium/formoterol metered dose inhaler formulated using co-suspension delivery technology. Eur J Pharm Sci 2017; 111:450-457. [PMID: 29055732 DOI: 10.1016/j.ejps.2017.10.026] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2017] [Revised: 09/27/2017] [Accepted: 10/18/2017] [Indexed: 11/16/2022]
Abstract
This gamma scintigraphy imaging study was the first to assess pulmonary and extrathoracic deposition and regional lung deposition patterns of a radiolabelled long-acting muscarinic antagonist/long-acting β2-agonist fixed-dose combination glycopyrronium/formoterol fumarate dihydrate (GFF) 14.4/10μg (equivalent to glycopyrrolate/formoterol fumarate 18/9.6μg), delivered by pressurized metered dose inhaler (pMDI) using novel co-suspension delivery technology. In this Phase I, randomized, single-centre, single-blind, single-dose, two-treatment, crossover, placebo-controlled study (PT003020), 10 healthy male adults received two actuations of GFF pMDI (7.2/5.0μg per actuation) and placebo pMDI (containing phospholipid-based porous particles without active pharmaceutical ingredient), both radiolabelled with 99mTc, up to 5MBq per actuation. Gamma scintigraphy images of lungs, stomach, head and neck were recorded. In addition, images of the actuators after use, collected mouth washings and exhalation filters were acquired. On average, 38.4% of the emitted dose of radiolabelled GFF pMDI, and 32.8% of radiolabelled placebo pMDI, was deposited in the lungs. The percentage emitted dose detected in the oropharyngeal and stomach regions was 61.4% and 66.9% for radiolabelled GFF pMDI and placebo pMDI, respectively. For both treatments, ≤0.25% of the emitted dose was detected in the exhalation filter. The normalized outer/inner ratio was 0.57 and 0.59 for radiolabelled GFF pMDI and placebo pMDI, respectively, and the standardized central/peripheral ratio was 1.85 and 1.94 respectively, indicating delivery of both co-suspension delivery technology formulations throughout the airways. There were no new or unexpected safety findings. In conclusion, both formulations were efficiently and uniformly deposited in the lungs with similar regional deposition patterns, oropharyngeal and stomach deposition, exhalation fraction and actuator-recovered dose.
Collapse
Affiliation(s)
| | | | | | | | | | - Chad Orevillo
- Former employee of Pearl Therapeutics Inc., Morristown, NJ, USA
| | - Andrea Maes
- Pearl Therapeutics Inc., Morristown, NJ, USA
| | | | - Omar S Usmani
- National Heart and Lung Institute (NHLI), Imperial College London, Royal Brompton Hospital, London, UK
| |
Collapse
|
65
|
Singh D, Corradi M, Spinola M, Papi A, Usmani OS, Scuri M, Petruzzelli S, Vestbo J. Triple therapy in COPD: new evidence with the extrafine fixed combination of beclomethasone dipropionate, formoterol fumarate, and glycopyrronium bromide. Int J Chron Obstruct Pulmon Dis 2017; 12:2917-2928. [PMID: 29062229 PMCID: PMC5638574 DOI: 10.2147/copd.s146822] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
The goals of COPD therapy are to prevent and control symptoms, reduce the frequency and severity of exacerbations, and improve exercise tolerance. The triple combination therapy of inhaled corticosteroids (ICSs), long-acting beta2 agonists (LABAs), and long-acting muscarinic antagonists (LAMAs) has become an option for maintenance treatment of COPD and as a “step-up” therapy from single or double combination treatments. There is evidence that triple combination ICS/LABA/LAMA with different inhalers improves lung function, symptoms, and health status and reduces exacerbations. A new triple fixed-dose combination of extrafine beclomethasone dipropionate (100 µg/puff)/formoterol fumarate (6 µg/puff)/glycopyrronium bromide (12.5 µg/puff) has been developed as a hydrofluoroalkane pressurized metered dose inhaler. Two large pivotal studies showed that this extrafine fixed ICS/LABA/LAMA triple combination is superior to fixed ICS/LABA combined therapy and also superior to the LAMA tiotropium in terms of lung function and exacerbation prevention in COPD patients at risk of exacerbation. This review considers the new information provided by these clinical trials of extrafine triple therapy and the implications for the clinical management of COPD patients.
Collapse
Affiliation(s)
- Dave Singh
- Division of Infection, Immunity and Respiratory Medicine, University of Manchester, Manchester, UK
| | - Massimo Corradi
- Department of Medicine and Surgery, University of Parma, Parma, Italy
| | | | - Alberto Papi
- Department of Medical Sciences, Research Centre on Asthma and COPD, University of Ferrara, Ferrara, Italy
| | - Omar S Usmani
- National Heart and Lung Institute, Imperial College London, London, UK
| | | | | | - Jørgen Vestbo
- Division of Infection, Immunity and Respiratory Medicine, University of Manchester, Manchester, UK
| |
Collapse
|
66
|
Sonnappa S, McQueen B, Postma DS, Martin RJ, Roche N, Grigg J, Guilbert T, Gouder C, Pizzichini E, Niimi A, Phipatanakul W, Chisholm A, Dandurand RJ, Kaplan A, Israel E, Papi A, van Aalderen WMC, Usmani OS, Price DB. Extrafine Versus Fine Inhaled Corticosteroids in Relation to Asthma Control: A Systematic Review and Meta-Analysis of Observational Real-Life Studies. J Allergy Clin Immunol Pract 2017; 6:907-915.e7. [PMID: 28941668 DOI: 10.1016/j.jaip.2017.07.032] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 01/04/2017] [Revised: 07/11/2017] [Accepted: 07/13/2017] [Indexed: 10/18/2022]
Abstract
BACKGROUND The particle size of inhaled corticosteroids (ICSs) may affect airway drug deposition and effectiveness. OBJECTIVE To compare the effectiveness of extrafine ICSs (mass median aerodynamic diameter, <2 μm) versus fine-particle ICSs administered as ICS monotherapy or ICS-long-acting β-agonist combination therapy by conducting a meta-analysis of observational real-life asthma studies to estimate the treatment effect of extrafine ICSs. METHODS MEDLINE and EMBASE databases were reviewed for asthma observational comparative effectiveness studies from January 2004 to June 2016. Studies were included if they reported odds and relative risk ratios and met all inclusion criteria (Respiratory Effectiveness Group/European Academy of Allergy and Clinical Immunology quality standards, comparison of extrafine ICSs with same or different ICS molecule, ≥12-month follow-up). End-point data (asthma control, exacerbations, prescribed ICS dose) were pooled. Random-effects meta-analysis modeling was used. The study protocol is published in the PROSPERO register CRD42016039137. RESULTS Seven studies with 33,453 subjects aged 5 to 80 years met eligibility criteria for inclusion. Six studies used extrafine beclometasone propionate and 1 study used both extrafine beclometasone propionate and extrafine ciclesonide as comparators with fine-particle ICSs. The overall odds of achieving asthma control were significantly higher for extrafine ICSs compared with fine-particle ICSs (odds ratio, 1.34; 95% CI, 1.22-1.46). Overall exacerbation rate ratios (0.84; 95% CI, 0.73-0.97) and ICS dose (weighted mean difference, -170 μg; 95% CI, -222 to -118 μg) were significantly lower for extrafine ICSs compared with fine-particle ICSs. CONCLUSIONS This meta-analysis demonstrates that extrafine ICSs have significantly higher odds of achieving asthma control with lower exacerbation rates at significantly lower prescribed doses than fine-particle ICSs.
Collapse
Affiliation(s)
- Samatha Sonnappa
- Observational and Pragmatic Research Institute Pte Ltd, Singapore; Department of Respiratory Paediatrics, Rainbow Children's Hospital, Bengaluru, India
| | - Brett McQueen
- University of Colorado Denver, Skaggs School of Pharmacy and Pharmaceutical Sciences, Aurora, Denver, Colo
| | - Dirkje S Postma
- Department of Pulmonary Medicine and Tuberculosis, University of Groningen, University Medical Center Groningen, Groningen, the Netherlands
| | - Richard J Martin
- National Jewish Health and the University of Colorado Denver, Denver, Colo
| | - Nicolas Roche
- Respiratory and Intensive Care Medicine, Cochin Hospital (APHP), University Paris Descartes (EA2511), Paris, France
| | - Jonathan Grigg
- Blizard Institute, Queen Mary University London, London, United Kingdom
| | - Theresa Guilbert
- Division of Pulmonology Medicine, Cincinnati Children's Hospital & Medical Center, Cincinnati, Ohio
| | - Caroline Gouder
- Department of Respiratory Medicine, Mater Dei Hospital, Msida, Malta
| | - Emilio Pizzichini
- Department of Medicine, Federal University of Santa Catarina, Santa Catarina, Brazil
| | - Akio Niimi
- Department of Respiratory Medicine, Allergy and Clinical Immunology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | | | - Alison Chisholm
- Respiratory Effectiveness Group, Oakington, Cambridge, United Kingdom
| | - Ronald J Dandurand
- Montreal Chest Institute, Meakins-Christie Laboratories and the McGill University Health Centre Research Institute, McGill University, Montreal, Canada
| | - Alan Kaplan
- Family Physician Airways Group of Canada, University of Toronto, Toronto, Ontario, Canada
| | - Elliot Israel
- Pulmonary and Critical Care Division, Brigham & Women's Hospital, Harvard Medical School, Boston, Mass
| | - Alberto Papi
- Department of Respiratory Medicine, University Hospital S. Anna, Ferrara, Italy
| | - Willem M C van Aalderen
- Department of Pediatric Respiratory Diseases, Emma Children's Hospital AMC, Amsterdam, The Netherlands
| | - Omar S Usmani
- National Heart and Lung Institute, Imperial College London & Royal Brompton Hospital, London, United Kingdom
| | - David B Price
- Observational and Pragmatic Research Institute Pte Ltd, Singapore; Academic Primary Care, Division of Applied Health Sciences, University of Aberdeen, Aberdeen, United Kingdom.
| |
Collapse
|
67
|
Lavorini F, Pistolesi M, Usmani OS. Erratum to: Recent advances in capsule-based dry powder inhaler technology. Multidiscip Respir Med 2017. [DOI: 10.4081/mrm.2017.245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
After publication of the article it was brought to our attention that resistance values of Breezahler (0.15 cmH2O/
L/min) and Handihaler (0.22 cmH2O/L/min) are incorrect.... [more]
Collapse
|
68
|
Lavorini F, Pistolesi M, Usmani OS. Erratum to: Recent advances in capsule-based dry powder inhaler technology. Multidiscip Respir Med 2017; 12:19. [PMID: 28652914 PMCID: PMC5482936 DOI: 10.1186/s40248-017-0100-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2017] [Accepted: 06/16/2017] [Indexed: 11/13/2022] Open
Affiliation(s)
- Federico Lavorini
- Department of Experimental and Clinical Medicine, Careggi University Hospital, Florence, Italy
| | - Massimo Pistolesi
- Department of Experimental and Clinical Medicine, Careggi University Hospital, Florence, Italy
| | - Omar S Usmani
- National Heart and Lung Institute, Imperial College London& Royal Brompton Hospital, London, UK
| |
Collapse
|
69
|
Lavorini F, Pistolesi M, Usmani OS. Recent advances in capsule-based dry powder inhaler technology. Multidiscip Respir Med 2017; 12:11. [PMID: 28536654 PMCID: PMC5439154 DOI: 10.1186/s40248-017-0092-5] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2016] [Accepted: 04/12/2017] [Indexed: 11/26/2022] Open
Abstract
Pulmonary drug delivery is currently the focus of accelerated research and development because of the potential to produce maximum therapeutic benefit to patients by directly targeting drug to the site of pathology in the lungs. Among the available delivery options, the dry powder inhaler (DPI) is the preferred device for the treatment of an increasingly diverse range of diseases. However, because drug delivery from a DPI involves a complex interaction between the device and the patient, the engineering development of this medical technology is proving to be a great challenge. Development of DPI systems that target the delivery of fine drug particles to the deeper airways in the lungs using a combination of improved drug formulations and enhanced delivery device technologies means that each of these factors contributes to overall performance of the aerosol system. There are a large range of devices that are currently available, or under development, for clinical use, however no individual device shows superior clinical efficacy. A major concern that is very relevant in day-to-day clinical practice is the inter- and intra-patient variability of the drug dosage delivered to the deep lungs from the inhalation devices, where the extent of variability depends on the drug formulation, the device design, and the patient’s inhalation profile. This variability may result in under-dosing of drug to the patient and potential loss of pharmacological efficacy. This article reviews recent advances in capsule-based DPI technology and the introduction of the ‘disposable’ DPI device.
Collapse
Affiliation(s)
- Federico Lavorini
- Department of Experimental and Clinical Medicine, Careggi University Hospital, Largo Brambilla 3, 50134 Florence, Italy
| | - Massimo Pistolesi
- Department of Experimental and Clinical Medicine, Careggi University Hospital, Largo Brambilla 3, 50134 Florence, Italy
| | - Omar S Usmani
- National Heart and Lung Institute, Imperial College London& Royal Brompton Hospital, London, UK
| |
Collapse
|
70
|
Abstract
Pulmonary drug delivery is currently the focus of accelerated research and development because of the potential to produce maximum therapeutic benefit to patients by directly targeting drug to the site of pathology in the lungs. Among the available delivery options, the dry powder inhaler (DPI) is the preferred device for the treatment of an increasingly diverse range of diseases. However, because drug delivery from a DPI involves a complex interaction between the device and the patient, the engineering development of this medical technology is proving to be a great challenge. Development of DPI systems that target the delivery of fine drug particles to the deeper airways in the lungs using a combination of improved drug formulations and enhanced delivery device technologies means that each of these factors contributes to overall performance of the aerosol system. There are a large range of devices that are currently available, or under development, for clinical use, however no individual device shows superior clinical efficacy. A major concern that is very relevant in day-to-day clinical practice is the inter- and intra-patient variability of the drug dosage delivered to the deep lungs from the inhalation devices, where the extent of variability depends on the drug formulation, the device design, and the patient’s inhalation profile. This variability may result in under-dosing of drug to the patient and potential loss of pharmacological efficacy. This article reviews recent advances in capsule-based DPI technology and the introduction of the ‘disposable’ DPI device.
Collapse
|
71
|
Honkoop PJ, Simpson A, Bonini M, Snoeck-Stroband JB, Meah S, Fan Chung K, Usmani OS, Fowler S, Sont JK. MyAirCoach: the use of home-monitoring and mHealth systems to predict deterioration in asthma control and the occurrence of asthma exacerbations; study protocol of an observational study. BMJ Open 2017; 7:e013935. [PMID: 28119390 PMCID: PMC5278295 DOI: 10.1136/bmjopen-2016-013935] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
INTRODUCTION Asthma is a variable lung condition whereby patients experience periods of controlled and uncontrolled asthma symptoms. Patients who experience prolonged periods of uncontrolled asthma have a higher incidence of exacerbations and increased morbidity and mortality rates. The ability to determine and to predict levels of asthma control and the occurrence of exacerbations is crucial in asthma management. Therefore, we aimed to determine to what extent physiological, behavioural and environmental data, obtained by mobile healthcare (mHealth) and home-monitoring sensors, as well as patient characteristics, can be used to predict episodes of uncontrolled asthma and the onset of asthma exacerbations. METHODS AND ANALYSIS In an 1-year observational study, patients will be provided with mHealth and home-monitoring systems to record daily measurements for the first-month (phase I) and weekly measurements during a follow-up period of 11 months (phase II). Our study population consists of 150 patients, aged ≥18 years, with a clinician's diagnosis of asthma, currently on controller medication, with uncontrolled asthma and/or minimally one exacerbation in the past 12 months. They will be enrolled over three participating centres, including Leiden, London and Manchester. Our main outcomes are the association between physiological, behavioural and environmental data and (1) the loss of asthma control and (2) the occurrence of asthma exacerbations. ETHICS This study was approved by the Medical Ethics Committee of the Leiden University Medical Center in the Netherlands and by the NHS ethics service in the UK. TRIAL REGISTRATION NUMBER NCT02774772.
Collapse
Affiliation(s)
- Persijn J Honkoop
- Department of Quality of Care, Leiden University Medical Center, Leiden, The Netherlands
- Department of Medical Decision Making, Leiden University Medical Center, Leiden, The Netherlands
| | - Andrew Simpson
- Centre for Respiratory Medicine and Allergy, Institute of Inflammation and Repair, Manchester Academic Health Science and Centre, The University of Manchester University Hospital of South Manchester, NHS Foundation Trust, Manchester, UK
| | - Matteo Bonini
- National Heart and Lung Institute (NHLI), Imperial College London, London, UK
| | - Jiska B Snoeck-Stroband
- Department of Quality of Care, Leiden University Medical Center, Leiden, The Netherlands
- Department of Medical Decision Making, Leiden University Medical Center, Leiden, The Netherlands
| | - Sally Meah
- National Heart and Lung Institute (NHLI), Imperial College London, London, UK
| | - Kian Fan Chung
- National Heart and Lung Institute (NHLI), Imperial College London, London, UK
| | - Omar S Usmani
- National Heart and Lung Institute (NHLI), Imperial College London, London, UK
| | - Stephen Fowler
- Centre for Respiratory Medicine and Allergy, Institute of Inflammation and Repair, Manchester Academic Health Science and Centre, The University of Manchester University Hospital of South Manchester, NHS Foundation Trust, Manchester, UK
| | - Jacob K Sont
- Department of Quality of Care, Leiden University Medical Center, Leiden, The Netherlands
- Department of Medical Decision Making, Leiden University Medical Center, Leiden, The Netherlands
| |
Collapse
|
72
|
Verbanck S, Ghorbaniasl G, Biddiscombe MF, Dragojlovic D, Ricks N, Lacor C, Ilsen B, de Mey J, Schuermans D, Underwood SR, Barnes PJ, Vincken W, Usmani OS. Inhaled Aerosol Distribution in Human Airways: A Scintigraphy-Guided Study in a 3D Printed Model. J Aerosol Med Pulm Drug Deliv 2016; 29:525-533. [DOI: 10.1089/jamp.2016.1291] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Affiliation(s)
- Sylvia Verbanck
- Respiratory Division, University Hospital UZ Brussel, Vrije Universiteit Brussel, Brussels, Belgium
| | - Ghader Ghorbaniasl
- Research Group Fluid Mechanics and Thermodynamics, Department of Mechanical Engineering, Vrije Universiteit Brussel, Brussels, Belgium
| | - Martyn F. Biddiscombe
- Airway Disease Section, National Heart and Lung Institute, Imperial College London and Royal Brompton Hospital, London, United Kingdom
- Nuclear Medicine Department, Royal Brompton Hospital, London, United Kingdom
| | - Dusica Dragojlovic
- Research Group Fluid Mechanics and Thermodynamics, Department of Mechanical Engineering, Vrije Universiteit Brussel, Brussels, Belgium
| | - Nathan Ricks
- Research Group Fluid Mechanics and Thermodynamics, Department of Mechanical Engineering, Vrije Universiteit Brussel, Brussels, Belgium
| | - Chris Lacor
- Research Group Fluid Mechanics and Thermodynamics, Department of Mechanical Engineering, Vrije Universiteit Brussel, Brussels, Belgium
| | - Bart Ilsen
- Radiology Department, University Hospital UZ Brussel, Vrije Universiteit Brussel, Brussels, Belgium
| | - Johan de Mey
- Radiology Department, University Hospital UZ Brussel, Vrije Universiteit Brussel, Brussels, Belgium
| | - Daniel Schuermans
- Respiratory Division, University Hospital UZ Brussel, Vrije Universiteit Brussel, Brussels, Belgium
| | | | - Peter J. Barnes
- Airway Disease Section, National Heart and Lung Institute, Imperial College London and Royal Brompton Hospital, London, United Kingdom
| | - Walter Vincken
- Respiratory Division, University Hospital UZ Brussel, Vrije Universiteit Brussel, Brussels, Belgium
| | - Omar S. Usmani
- Airway Disease Section, National Heart and Lung Institute, Imperial College London and Royal Brompton Hospital, London, United Kingdom
| |
Collapse
|
73
|
Braido F, Scichilone N, Lavorini F, Usmani OS, Dubuske L, Boulet LP, Mosges R, Nunes C, Sánchez-Borges M, Ansotegui IJ, Ebisawa M, Levi-Schaffer F, Rosenwasser LJ, Bousquet J, Zuberbier T, Canonica GW. Manifesto on small airway involvement and management in asthma and chronic obstructive pulmonary disease: an Interasma (Global Asthma Association - GAA) and World Allergy Organization (WAO) document endorsed by Allergic Rhinitis and its Impact on Asthma (ARIA) and Global Allergy and Asthma European Network (GA 2LEN). Asthma Res Pract 2016; 2:12. [PMID: 27965780 PMCID: PMC5142416 DOI: 10.1186/s40733-016-0027-5] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2016] [Accepted: 08/22/2016] [Indexed: 11/13/2022] Open
Abstract
Evidence that enables us to identify, assess, and access the small airways in asthma and chronic obstructive pulmonary disease (COPD) has led INTERASMA (Global Asthma Association) and WAO to take a position on the role of the small airways in these diseases. Starting from an extensive literature review, both organizations developed, discussed, and approved the manifesto, which was subsequently approved and endorsed by the chairs of ARIA and GA2LEN. The manifesto describes the evidence gathered to date and defines and proposes issues on small airway involvement and management in asthma and COPD with the aim of challenging assumptions, fostering commitment, and bringing about change. The small airways (defined as those with an internal diameter <2 mm) are involved in the pathogenesis of asthma and COPD and are the major determinant of airflow obstruction in these diseases. Various tests are available for the assessment of the small airways, and their results must be integrated to confirm a diagnosis of small airway dysfunction. In asthma and COPD, the small airways play a key role in attempts to achieve disease control and better outcomes. Small-particle inhaled formulations (defined as those that, owing to their size [usually <2 μm], ensure more extensive deposition in the lung periphery than large molecules) have proved beneficial in patients with asthma and COPD, especially those in whom small airway involvement is predominant. Functional and biological tools capable of accurately assessing the lung periphery and more intensive use of currently available tools are necessary. In patients with suspected COPD or asthma, small airway involvement must be assessed using currently available tools. In patients with subotpimal disease control and/or functional or biological signs of disease activity, the role of small airway involvement should be assessed and treatment tailored. Therefore, the choice between large- and small-particle inhaled formulations must reflect the physician’s considerations of disease features, phenotype, and response to previous therapy. This article is being co-published in Asthma Research and Practice and the World Allergy Organization Journal.
Collapse
Affiliation(s)
- F Braido
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - N Scichilone
- Dipartimento Biomedico di Medicina Interna e Specialistica, University of Palermo, Palermo, Italy
| | - F Lavorini
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - O S Usmani
- Airway Disease Section, National Heart and Lung Institute, Imperial College London, Royal Brompton Hospital, London, UK
| | - L Dubuske
- Immunology Research Institute of New England, Harvard, USA
| | - L P Boulet
- Centre de recherche de l'Institut universitaire de cardiologie et de pneumologie de Québec, Québec, Canada
| | - R Mosges
- Institute of Medical Statistics, Informatics and Epidemiology, University Hospital of Cologne, Cologne, Germany
| | - C Nunes
- Centro de ImmunoAlergologia de Algarve, Porto, Portugal
| | - M Sánchez-Borges
- Centro Medico Docente La Trinidad, Caracas, Venezuela ; Clinica El Avila, Caracas, Venezuela
| | - I J Ansotegui
- Department of Allergy and Immunology, Hospital Quirón Bizkaia, Carretera Leioa-Inbe, Erandio, Bilbao, Spain
| | - M Ebisawa
- Department of Allergy, Clinical Research Center for Allergy & Rheumatology, Sagamihara National Hospital, Sagamihara, Kanagawa Japan
| | - F Levi-Schaffer
- Department of Pharmacology and Experimental Therapeutics, Institute for Drug Research, School of Pharmacy, Faculty of Medicine, The Hebrew University of Jerusalem, Jerusalem, Israel
| | - L J Rosenwasser
- University of Missouri - Kansas City, School of Medicine, Kansas City, Missouri USA
| | - J Bousquet
- Service des Maladies Respiratoires, Hopital Arnaud de Villeneuve, Montpellier, France
| | - T Zuberbier
- Department of Dermatology and Allergy, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - G Walter Canonica
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | | | | | | | | |
Collapse
|
74
|
Braido F, Scichilone N, Lavorini F, Usmani OS, Dubuske L, Boulet LP, Mosges R, Nunes C, Sanchez-Borges M, Ansotegui IJ, Ebisawa M, Levi-Schaffer F, Rosenwasser LJ, Bousquet J, Zuberbier T, Canonica GW, Cruz A, Yanez A, Yorgancioglu A, Deleanu D, Rodrigo G, Berstein J, Ohta K, Vichyanond P, Pawankar R, Gonzalez-Diaz SN, Nakajima S, Slavyanskaya T, Fink-Wagner A, Loyola CB, Ryan D, Passalacqua G, Celedon J, Ivancevich JC, Dobashi K, Zernotti M, Akdis M, Benjaponpitak S, Bonini S, Burks W, Caraballo L, El-Sayed ZA, Fineman S, Greenberger P, Hossny E, Ortega-Martell JA, Saito H, Tang M, Zhang L. Manifesto on small airway involvement and management in asthma and chronic obstructive pulmonary disease: an Interasma (Global Asthma Association - GAA) and World Allergy Organization (WAO) document endorsed by Allergic Rhinitis and its Impact on Asthma (ARIA) and Global Allergy and Asthma European Network (GA 2LEN). World Allergy Organ J 2016; 9:37. [PMID: 27800118 PMCID: PMC5084415 DOI: 10.1186/s40413-016-0123-2] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2016] [Accepted: 08/24/2016] [Indexed: 12/21/2022] Open
Abstract
Evidence that enables us to identify, assess, and access the small airways in asthma and chronic obstructive pulmonary disease (COPD) has led INTERASMA (Global Asthma Association) and WAO to take a position on the role of the small airways in these diseases. Starting from an extensive literature review, both organizations developed, discussed, and approved the manifesto, which was subsequently approved and endorsed by the chairs of ARIA and GA2LEN. The manifesto describes the evidence gathered to date and defines and proposes issues on small airway involvement and management in asthma and COPD with the aim of challenging assumptions, fostering commitment, and bringing about change. The small airways (defined as those with an internal diameter <2 mm) are involved in the pathogenesis of asthma and COPD and are the major determinant of airflow obstruction in these diseases. Various tests are available for the assessment of the small airways, and their results must be integrated to confirm a diagnosis of small airway dysfunction. In asthma and COPD, the small airways play a key role in attempts to achieve disease control and better outcomes. Small-particle inhaled formulations (defined as those that, owing to their size [usually <2 μm], ensure more extensive deposition in the lung periphery than large molecules) have proved beneficial in patients with asthma and COPD, especially those in whom small airway involvement is predominant. Functional and biological tools capable of accurately assessing the lung periphery and more intensive use of currently available tools are necessary. In patients with suspected COPD or asthma, small airway involvement must be assessed using currently available tools. In patients with subotpimal disease control and/or functional or biological signs of disease activity, the role of small airway involvement should be assessed and treatment tailored. Therefore, the choice between large- and small-particle inhaled formulations must reflect the physician’s considerations of disease features, phenotype, and response to previous therapy. This article is being co-published in Asthma Research and Practice and the World Allergy Organization Journal.
Collapse
Affiliation(s)
- F Braido
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - N Scichilone
- Dipartimento Biomedico di Medicina Interna e Specialistica, University of Palermo, Palermo, Italy
| | - F Lavorini
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - O S Usmani
- Airway Disease Section, National Heart and Lung Institute, Imperial College London, Royal Brompton Hospital, London, UK
| | - L Dubuske
- Immunology Research Institute of New England, Harvard, USA
| | - L P Boulet
- Centre de recherche de l'Institut universitaire de cardiologie et de pneumologie de Québec, Québec, Canada
| | - R Mosges
- Institute of Medical Statistics, Informatics and Epidemiology, University Hospital of Cologne, Cologne, Germany
| | - C Nunes
- Centro de ImmunoAlergologia de Algarve, Porto, Portugal
| | - M Sanchez-Borges
- Centro Medico Docente La Trinidad, Caracas, Venezuela ; Clinica El Avila, Caracas, Venezuela
| | - I J Ansotegui
- Department of Allergy and Immunology, Hospital Quirón Bizkaia, Carretera Leioa-Inbe, Erandio, Bilbao Spain
| | - M Ebisawa
- Department of Allergy, Clinical Research Center for Allergy & Rheumatology, Sagamihara National Hospital, Sagamihara, Kanagawa Japan
| | - F Levi-Schaffer
- Department of Pharmacology and Experimental Therapeutics, Institute for Drug Research, School of Pharmacy, Faculty of Medicine, The Hebrew University of Jerusalem, Jerusalem, Israel
| | - L J Rosenwasser
- University of Missouri - Kansas City, School of Medicine, Kansas City, Missouri USA
| | - J Bousquet
- Service des Maladies Respiratoires, Hopital Arnaud de Villeneuve, Montpellier, France
| | - T Zuberbier
- Department of Dermatology and Allergy, Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - G Walter Canonica
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - A Cruz
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - A Yanez
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - A Yorgancioglu
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - D Deleanu
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - G Rodrigo
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - J Berstein
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - K Ohta
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - P Vichyanond
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - R Pawankar
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - S N Gonzalez-Diaz
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - S Nakajima
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - T Slavyanskaya
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - A Fink-Wagner
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - C Baez Loyola
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - D Ryan
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - G Passalacqua
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - J Celedon
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - J C Ivancevich
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - K Dobashi
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - M Zernotti
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - M Akdis
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - S Benjaponpitak
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - S Bonini
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - W Burks
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - L Caraballo
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - Z Awad El-Sayed
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - S Fineman
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - P Greenberger
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - E Hossny
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - J A Ortega-Martell
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - H Saito
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - M Tang
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | - L Zhang
- Allergy and Respiratory Diseases Department DIMI, University of Genoa, IRCCS AOU San Martino-IST, Genoa, Italy
| | | | | | | |
Collapse
|
75
|
Lavorini F, Pedersen S, Usmani OS. Dilemmas, Confusion, and Misconceptions Related to Small Airways Directed Therapy. Chest 2016; 151:1345-1355. [PMID: 27522955 DOI: 10.1016/j.chest.2016.07.035] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2016] [Revised: 07/20/2016] [Accepted: 07/30/2016] [Indexed: 11/26/2022] Open
Abstract
During the past decade, there has been increasing evidence that the small airways (ie, airways < 2 mm in internal diameter) contribute substantially to the pathophysiologic and clinical expression of asthma and COPD. The increased interest in small airways is, at least in part, a result of innovation in small-particle aerosol formulations that better target the distal lung and also advanced physiologic methods of assessing small airway responses. Increasing the precision of drug deposition may improve targeting of specific diseases or receptor locations, decrease airway drug exposure and adverse effects, and thereby increase the efficiency and effectiveness of inhaled drug delivery. The availability of small-particle aerosols of corticosteroids, bronchodilators, or their combination enables a higher total lung deposition and better peripheral lung penetration and provides added clinical benefit, compared with large-particle aerosol treatment. However, a number of questions remain unanswered about the pragmatic approach relevant for clinicians to consider the role of small airways directed therapy in the day-to-day management of asthma and COPD. We thus have tried to clarify the dilemmas, confusion, and misconceptions related to small airways directed therapy. To this end, we have reviewed all studies on small-particle aerosol therapy systematically to address the dilemmas, confusion, and misconceptions related to small airways directed therapy.
Collapse
Affiliation(s)
- Federico Lavorini
- Department of Experimental and Clinical Medicine, Careggi University Hospital, Florence, Italy.
| | - Søren Pedersen
- Pediatric Research Unit, University of Southern Denmark, Kolding Hospital, Kolding, Denmark
| | - Omar S Usmani
- Airways Disease Section, National Heart and Lung Institute, Imperial College London and Royal Brompton Hospital, London, England
| | | |
Collapse
|
76
|
Kemppinen A, Gardener E, Thomas V, Raju P, Callan C, McLoughlin A, Woodhead V, Brady A, Juniper EF, Barnes PJ, Usmani OS, Price D. AB038. Pragmatic trial comparing continuing Seretide® MDI with changing to Flutiform® in asthma. J Thorac Dis 2016. [DOI: 10.21037/jtd.2016.s038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
77
|
Kemppinen A, Gardener E, Thomas V, Raju P, Callan C, McLoughlin A, Woodhead V, Brady A, Juniper EF, Barnes P, Usmani OS, Price D. AB039. Pragmatic trial stepping down Flutiform® in patients maintained on high dose ICS. J Thorac Dis 2016. [DOI: 10.21037/jtd.2016.s039] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
78
|
Levy ML, Dekhuijzen P, Barnes PJ, Broeders M, Corrigan CJ, Chawes BL, Corbetta L, Dubus JC, Hausen T, Lavorini F, Roche N, Sanchis J, Usmani OS, Viejo J, Vincken W, Voshaar T, Crompton GK, Pedersen S. Erratum: Inhaler technique: facts and fantasies. A view from the Aerosol Drug Management Improvement Team (ADMIT). NPJ Prim Care Respir Med 2016; 26:16028. [PMID: 31265706 PMCID: PMC4881806 DOI: 10.1038/npjpcrm.2016.28] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
[This corrects the article DOI: 10.1038/npjpcrm.2016.17.].
Collapse
|
79
|
Levy ML, Dekhuijzen PNR, Barnes PJ, Broeders M, Corrigan CJ, Chawes BL, Corbetta L, Dubus JC, Hausen T, Lavorini F, Roche N, Sanchis J, Usmani OS, Viejo J, Vincken W, Voshaar T, Crompton GK, Pedersen S. Inhaler technique: facts and fantasies. A view from the Aerosol Drug Management Improvement Team (ADMIT). NPJ Prim Care Respir Med 2016; 26:16017. [PMID: 27098045 PMCID: PMC4839029 DOI: 10.1038/npjpcrm.2016.17] [Citation(s) in RCA: 50] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2015] [Revised: 01/23/2016] [Accepted: 02/09/2016] [Indexed: 01/04/2023] Open
Abstract
Health professionals tasked with advising patients with asthma and chronic obstructive pulmonary disease (COPD) how to use inhaler devices properly and what to do about unwanted effects will be aware of a variety of commonly held precepts. The evidence for many of these is, however, lacking or old and therefore in need of re-examination. Few would disagree that facilitating and encouraging regular and proper use of inhaler devices for the treatment of asthma and COPD is critical for successful outcomes. It seems logical that the abandonment of unnecessary or ill-founded practices forms an integral part of this process: the use of inhalers is bewildering enough, particularly with regular introduction of new drugs, devices and ancillary equipment, without unnecessary and pointless adages. We review the evidence, or lack thereof, underlying ten items of inhaler ‘lore’ commonly passed on by health professionals to each other and thence to patients. The exercise is intended as a pragmatic, evidence-informed review by a group of clinicians with appropriate experience. It is not intended to be an exhaustive review of the literature; rather, we aim to stimulate debate, and to encourage researchers to challenge some of these ideas and to provide new, updated evidence on which to base relevant, meaningful advice in the future. The discussion on each item is followed by a formal, expert opinion by members of the ADMIT Working Group.
Collapse
Affiliation(s)
- Mark L Levy
- General Practitioner and Respiratory Lead, Harrow, London, UK
| | - P N R Dekhuijzen
- Radboud University Nijmegen Medical Centre, Nijmegen, The Netherlands
| | - P J Barnes
- National Heart and Lung Institute, Imperial College London, London, UK
| | - M Broeders
- University Medical Centre Nijmegen, Nijmegen, The Netherlands
| | - C J Corrigan
- Department of Respiratory Medicine and Allergy, King's College London School of Medicine, London, UK
| | - B L Chawes
- COPSAC, Copenhagen Prospective Studies on Asthma in Childhood, Herlev and Gentofte Hospital, University of Copenhagen, Copenhagen, Denmark
| | - L Corbetta
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - J C Dubus
- Unité de Medicine Infantile, Marseille, France
| | | | - F Lavorini
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - N Roche
- Service de Pneumologie et Soins Intensifs Respiratoires, Groupe Hospitalier Cochin, Université Paris-Descartes, Paris, France
| | - J Sanchis
- Departament de Pneumologia, Hospital de la Santa Creuide Sant Pau, Universitat Autónoma de Barcelona, Barcelona, Spain
| | - Omar S Usmani
- NIHR Career Development Fellow, National Heart and Lung Institute (NHLI), Imperial College London, UK.,Royal Brompton Hospital, London, UK
| | - J Viejo
- Hospital General Yagüe de Burgos, Spain
| | - W Vincken
- Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Dienst Pneumologie, Brussels, Belgium
| | | | | | - Soren Pedersen
- Pediatric Research Unit, University of Southern Denmark, Kolding Hospital, Kolding, Denmark
| |
Collapse
|
80
|
Kikidis D, Konstantinos V, Tzovaras D, Usmani OS. The Digital Asthma Patient: The History and Future of Inhaler Based Health Monitoring Devices. J Aerosol Med Pulm Drug Deliv 2016; 29:219-32. [PMID: 26919553 DOI: 10.1089/jamp.2015.1267] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023] Open
Abstract
The wave of digital health is continuously growing and promises to transform healthcare and optimize the patients' experience. Asthma is in the center of these digital developments, as it is a chronic disease that requires the continuous attention of both health care professionals and patients themselves. The accurate and timely assessment of the state of asthma is the fundamental basis of digital health approaches and is also the most significant factor toward the preventive and efficient management of the disease. Furthermore, the necessity of inhaled medication offers a basic platform upon which modern technologies can be integrated, namely the inhaler device itself. Inhaler-based monitoring devices were introduced in the beginning of the 1980s and have been evolving but mainly for the assessment of medication adherence. As technology progresses and novel sensing components are becoming available, the enhancement of inhalers with a wider range of monitoring capabilities holds the promise to further support and optimize asthma self-management. The current article aims to take a step for the mapping of this territory and start the discussion among healthcare professionals and engineers for the identification and the development of technologies that can offer personalized asthma self-management with clinical significance. In this direction, a technical review of inhaler based monitoring devices is presented, together with an overview of their use in clinical research. The aggregated results are then summarized and discussed for the identification of key drivers that can lead the future of inhalers.
Collapse
Affiliation(s)
- Dimitrios Kikidis
- 1 Centre of Research & Technology-Hellas, Information Technologies Institute , Thessaloniki, Greece
| | - Votis Konstantinos
- 1 Centre of Research & Technology-Hellas, Information Technologies Institute , Thessaloniki, Greece
| | - Dimitrios Tzovaras
- 1 Centre of Research & Technology-Hellas, Information Technologies Institute , Thessaloniki, Greece
| | - Omar S Usmani
- 2 Imperial College London and Royal Brompton Hospital, National Heart and Lung Institute , London, United Kingdom
| |
Collapse
|
81
|
Darquenne C, Fleming JS, Katz I, Martin AR, Schroeter J, Usmani OS, Venegas J, Schmid O. Bridging the Gap Between Science and Clinical Efficacy: Physiology, Imaging, and Modeling of Aerosols in the Lung. J Aerosol Med Pulm Drug Deliv 2016; 29:107-26. [PMID: 26829187 DOI: 10.1089/jamp.2015.1270] [Citation(s) in RCA: 66] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
Development of a new drug for the treatment of lung disease is a complex and time consuming process involving numerous disciplines of basic and applied sciences. During the 2015 Congress of the International Society for Aerosols in Medicine, a group of experts including aerosol scientists, physiologists, modelers, imagers, and clinicians participated in a workshop aiming at bridging the gap between basic research and clinical efficacy of inhaled drugs. This publication summarizes the current consensus on the topic. It begins with a short description of basic concepts of aerosol transport and a discussion on targeting strategies of inhaled aerosols to the lungs. It is followed by a description of both computational and biological lung models, and the use of imaging techniques to determine aerosol deposition distribution (ADD) in the lung. Finally, the importance of ADD to clinical efficacy is discussed. Several gaps were identified between basic science and clinical efficacy. One gap between scientific research aimed at predicting, controlling, and measuring ADD and the clinical use of inhaled aerosols is the considerable challenge of obtaining, in a single study, accurate information describing the optimal lung regions to be targeted, the effectiveness of targeting determined from ADD, and some measure of the drug's effectiveness. Other identified gaps were the language and methodology barriers that exist among disciplines, along with the significant regulatory hurdles that need to be overcome for novel drugs and/or therapies to reach the marketplace and benefit the patient. Despite these gaps, much progress has been made in recent years to improve clinical efficacy of inhaled drugs. Also, the recent efforts by many funding agencies and industry to support multidisciplinary networks including basic science researchers, R&D scientists, and clinicians will go a long way to further reduce the gap between science and clinical efficacy.
Collapse
Affiliation(s)
- Chantal Darquenne
- 1 Department of Medicine, University of California , San Diego, La Jolla, California
| | - John S Fleming
- 2 National Institute of Health Research Biomedical Research Unit in Respiratory Disease , Southampton, United Kingdom .,3 Department of Medical Physics and Bioengineering, University Hospital Southampton NHS Foundation Trust , Southampton, United Kingdom
| | - Ira Katz
- 4 Medical R&D, Air Liquide Santé International, Centre de Recherche Paris-Saclay , Jouy-en-Josas, France .,5 Department of Mechanical Engineering, Lafayette College , Easton, Pennsylvania
| | - Andrew R Martin
- 6 Department of Mechanical Engineering, University of Alberta , Edmonton, Alberta, Canada
| | | | - Omar S Usmani
- 8 Airway Disease Section, National Heart and Lung Institute , Imperial College London and Royal Brompton Hospital, London, United Kingdom
| | - Jose Venegas
- 9 Department of Anesthesia (Bioengineering), MGH/Harvard, Boston, Massachusetts
| | - Otmar Schmid
- 10 Comprehensive Pneumology Center (CPC), Member of the German Center for Lung Research , Munich, Germany .,11 Institute of Lung Biology and Disease, Helmholtz Zentrum München-German Research Center for Environmental Health , Neuherberg, Germany
| |
Collapse
|
82
|
Abstract
Poor inhaler technique hampers the efficacy of drug therapy in asthma and chronic obstructive pulmonary disease. Not only does this affect individual patient care, but it also impacts on the wider health care economics associated with these conditions. Treatment guidelines recommend a systematic approach to drug class selection; however, standardization of inhaler selection is currently difficult owing to the complexity of the interaction between the inhaler device and the patient. Specifically, individual patient preference can influence how successful a treatment is overall. This article reviews inhaler devices from the patient perspective, with a particular focus on the dry powder inhaler HandiHaler(®) and Respimat(®) Soft Mist™ Inhaler. It discusses factors that influence device preference and treatment compliance and reviews tools that can aid health care professionals to better match inhaler devices to individual patients' needs.
Collapse
Affiliation(s)
- Pieter Nicolaas Richard Dekhuijzen
- Department of Pulmonary Diseases, Radboud University Medical Center, Nijmegen, the Netherlands
- Correspondence: Pieter Nicolaas Richard Dekhuijzen, Department of Pulmonary Diseases, Radboud University Medical Center, 6500 HB Nijmegen, the Netherlands, Tel +31 24 361 0325, Fax +31 24 361 0324, Email
| | - Federico Lavorini
- Department of Experimental and Clinical Medicine, Careggi University Hospital, Florence, Italy
| | - Omar S Usmani
- National Heart and Lung Institute, Imperial College London and Royal Brompton Hospital, London, UK
| |
Collapse
|
83
|
van de Kant KDG, Paredi P, Meah S, Kalsi HS, Barnes PJ, Usmani OS. The effect of body weight on distal airway function and airway inflammation. Obes Res Clin Pract 2015; 10:564-573. [PMID: 26620577 DOI: 10.1016/j.orcp.2015.10.005] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2015] [Revised: 09/14/2015] [Accepted: 10/05/2015] [Indexed: 11/28/2022]
Abstract
BACKGROUND/OBJECTIVES Obesity is a global health problem that adversely influences the respiratory system. We assessed the effects of body mass index (BMI) on distal airway function and airway inflammation. SUBJECTS/METHODS Impulse oscillometry (IOS) as a measure of distal airway function, together with spirometry, were assessed in adults with a range of different BMIs. Airway inflammation was assessed with the fraction of exhaled nitric oxide (FeNO) and participants exhaled at various exhalation flows to determine alveolar and bronchial NO. RESULTS In total 34 subjects were enrolled in the study; 19 subjects had a normal BMI (18.50-24.99), whilst 15 subjects were overweight (BMI 25.00-29.99), or obese (BMI ≥30). All subjects had normal spirometry. However, IOS measures of airway resistance (R) at 5Hz, 20Hz and frequency dependence (R5-20) were elevated in overweight/obese individuals, compared to subjects with a normal BMI (median (interquartile range)); 5Hz: 0.41 (0.37, 0.45) vs. 0.32 (0.30, 0.37)kPa/l/s; 20Hz: 0.34 (0.30, 0.37) vs. 0.30 (0.26, 0.33)kPa/l/s; R5-20: 0.06 (0.04, 0.11) vs. 0.03 (0.01, 0.05)kPa/l/s; p<0.05), whereas airway reactance at 20Hz was decreased in overweight/obese individuals (20Hz: 0.07 (0.03, 0.09) vs. 0.10 (0.07, 0.13)kPa/l/s, p=0.009; 5Hz: -0.12 (-0.15, -0.10) vs. -0.10 (-0.13, -0.09)kPa/l/s, p=0.07). In contrast, within-breath IOS measures (a sign of expiratory flow limitation) and FeNO inflammatory measures, did not differ between groups (p>0.05). CONCLUSIONS Being overweight has significant effects on distal and central airway function as determined by IOS, which is not detected by spirometry. Obesity does not influence airway inflammation as measured by FeNO. IOS is a reliable technique to identify airway abnormalities in the presence of normal spirometry in overweight people.
Collapse
Affiliation(s)
- Kim D G van de Kant
- National Heart and Lung Institute, Imperial College, Dovehouse Street, London SW3 6LY, United Kingdom.
| | - Paolo Paredi
- National Heart and Lung Institute, Imperial College, Dovehouse Street, London SW3 6LY, United Kingdom.
| | - Sally Meah
- National Heart and Lung Institute, Imperial College, Dovehouse Street, London SW3 6LY, United Kingdom.
| | - Harpal S Kalsi
- National Heart and Lung Institute, Imperial College, Dovehouse Street, London SW3 6LY, United Kingdom.
| | - Peter J Barnes
- National Heart and Lung Institute, Imperial College, Dovehouse Street, London SW3 6LY, United Kingdom.
| | - Omar S Usmani
- National Heart and Lung Institute, Imperial College, Dovehouse Street, London SW3 6LY, United Kingdom.
| |
Collapse
|
84
|
Gastaldi AC, Paredi P, Talwar A, Meah S, Barnes PJ, Usmani OS. Oscillating Positive Expiratory Pressure on Respiratory Resistance in Chronic Obstructive Pulmonary Disease With a Small Amount of Secretion: A Randomized Clinical Trial. Medicine (Baltimore) 2015; 94:e1845. [PMID: 26496331 PMCID: PMC4620777 DOI: 10.1097/md.0000000000001845] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
This study aims to evaluate the acute effects of an oscillating positive expiratory pressure device (flutter) on airways resistance in patients with chronic obstructive pulmonary disease (COPD).Randomized crossover study: 15 COPD outpatients from Asthma Lab-Royal Brompton Hospital underwent spirometry, impulse oscillometry (IOS) for respiratory resistance (R) and reactance (X), and fraction exhaled nitric oxide (FeNO) measures.Thirty minutes of flutter exercises: a "flutter-sham" procedure was used as a control, and airway responses after a short-acting bronchodilator were also assessed.Respiratory system resistance (R): in COPD patients an increase in X5insp (-0.21 to -0.33 kPa/L/s) and Fres (24.95 to 26.16 Hz) occurred immediately after flutter exercises without bronchodilator. Following 20 min of rest, a decrease in the R5, ΔR5, R20, X5, and Ax was observed, with R5, R20, and X5 values lower than baseline, with a moderate effect size; there were no changes in FeNO levels or spirometry.The use of flutter can decrease the respiratory system resistance and reactance and expiratory flow limitation in stable COPD patients with small amounts of secretions.
Collapse
Affiliation(s)
- Ada Clarice Gastaldi
- From the Physiotherapy Course, School of Medicine of Ribeirão Preto, São Paulo University, Brazil (ACG); Airway Disease Section, National Heart and Lung Institute, Imperial College London& Royal Brompton Hospital, United Kingdom (PP, SM, PJB, OSU); and Department of Physiology, All India Institute of Medical Sciences, India (AT)
| | | | | | | | | | | |
Collapse
|
85
|
Bikov A, Pride NB, Goldman MD, Hull JH, Horvath I, Barnes PJ, Usmani OS, Paredi P. Glottal Aperture and Buccal Airflow Leaks Critically Affect Forced Oscillometry Measurements. Chest 2015; 148:731-738. [DOI: 10.1378/chest.14-2644] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
|
86
|
Bonini M, Usmani OS. The role of the small airways in the pathophysiology of asthma and chronic obstructive pulmonary disease. Ther Adv Respir Dis 2015; 9:281-93. [PMID: 26037949 DOI: 10.1177/1753465815588064] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Chronic respiratory diseases, such as asthma and chronic obstructive pulmonary disease (COPD), represent a major social and economic burden for worldwide health systems. During recent years, increasing attention has been directed to the role of small airways in respiratory diseases, and their exact contribution to the pathophysiology of asthma and COPD continues to be clarified. Indeed, it has been suggested that small airways play a distinct role in specific disease phenotypes. Besides providing information on small airways structure and diagnostic procedures, this review therefore aims to present updated and evidence-based findings on the role of small airways in the pathophysiology of asthma and COPD. Most of the available information derives from either pathological studies or review articles and there are few data on the natural history of small airways disease in the onset or progression of asthma and COPD. Comparisons between studies on the role of small airways are hard to draw because both asthma and COPD are highly heterogeneous conditions. Most studies have been performed in small population samples, and different techniques to characterize aspects of small airways function have been employed in order to assess inflammation and remodelling. Most methods of assessing small airways dysfunction have been largely confined to research purposes, but some data are encouraging, supporting the utilization of certain techniques into daily clinical practice, particularly for early-stage diseases, when subjects are often asymptomatic and routine pulmonary function tests may be within normal ranges. In this context further clinical trials and real-life feedback on large populations are desirable.
Collapse
Affiliation(s)
- Matteo Bonini
- Lung Function Unit, Department of Public Health and Infectious Diseases, 'Sapienza' University of Rome, Viale dell'Universita', 37-00185 Rome, Italy
| | - Omar S Usmani
- Airway Disease Section, National Heart and Lung Institute, Imperial College London & Royal Brompton Hospital, London, UK
| |
Collapse
|
87
|
Abstract
The small airways are defined as those less than 2 mm in diameter. They are a major site of pathology in many lung diseases, not least chronic obstructive pulmonary disease (COPD) and asthma. The small airways are frequently involved early in the course of these diseases, with significant pathology demonstrable often before the onset of symptoms or changes in spirometry and imaging. Despite their importance, they have proven relatively difficult to study. This is in part due to their relative inaccessibility to biopsy and their small size which makes their imaging difficult. Traditional lung function tests may only become abnormal once there is a significant burden of disease within them. This has led to the term 'the quiet zone' of the lung. In recent years, more specialised tests have been developed which may detect these changes earlier, perhaps offering the possibility of earlier diagnosis and intervention. These tests are now moving from the realms of clinical research laboratories into routine clinical practice and are increasingly useful in the diagnosis and monitoring of respiratory diseases. This article gives an overview of small airways physiology and some of the routine and more advanced tests of airway function.
Collapse
Affiliation(s)
- William McNulty
- National Heart and lung Institute, Imperial College London and Royal Brompton Hospital, London, UK
| | | |
Collapse
|
88
|
Affiliation(s)
- Clara H K Wu
- Imperial College London, South Kensington Campus, London, United Kingdom.
| | - Keith Gunasekara
- Imperial College London, South Kensington Campus, London, United Kingdom
| | - James H Hull
- Airway Diseases, National Heart and Lung Institute, Imperial College London and the Cough Clinic, Royal Brompton & Harefield NHS Foundation Trust, London, United Kingdom
| | - Andras Bikov
- Department of Pulmonology, Semmelweis University, Budapest, Hungary
| | | | - Omar S Usmani
- Airway Diseases, National Heart and Lung Institute, Imperial College London and the Cough Clinic, Royal Brompton & Harefield NHS Foundation Trust, London, United Kingdom
| |
Collapse
|
89
|
Affiliation(s)
- Federico Lavorini
- Careggi University Hospital, Department of Experimental and Clinical Medicine, Florence, Italy
| | | |
Collapse
|
90
|
Usmani OS. Small airways dysfunction in asthma: evaluation and management to improve asthma control. Allergy Asthma Immunol Res 2014; 6:376-88. [PMID: 25228994 PMCID: PMC4161678 DOI: 10.4168/aair.2014.6.5.376] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/25/2014] [Accepted: 04/01/2014] [Indexed: 01/24/2023]
Abstract
The small airways have been neglected for many years, but interest in the topic has been rekindled with recent advances in measurement techniques to assess this region and also the ability to deliver therapeutics to the distal airways. Current levels of disease control in asthmatic patients remain poor and there are several contributory factors including; poor treatment compliance, heterogeneity of asthma phenotypes and associated comorbidities. However, the proposition that we may not be targeting all the inflammation that is present throughout the whole respiratory tree may also be an important factor. Indeed decades ago, pathologists and physiologists clearly identified the importance of small airways dysfunction in asthmatic patients. With improved inhaler technology to deliver drug to target the whole respiratory tree and more sensitive measures to assess the distal airways, we should certainly give greater consideration to treating the small airway region when seeing our asthmatic patients in clinic. The aim of this review is to address the relevance of small airways dysfunction in the daily clinical management of patients with asthma. In particular the role of small particle aerosols in the management of patients with asthma will be explored.
Collapse
Affiliation(s)
- Omar S Usmani
- Airway Disease Section, National Heart and Lung Institute, Imperial College London & Royal Brompton Hospital, London, UK
| |
Collapse
|
91
|
Corradi M, Chrystyn H, Cosio BG, Pirozynski M, Loukides S, Louis R, Spinola M, Usmani OS. NEXThaler, an innovative dry powder inhaler delivering an extrafine fixed combination of beclometasone and formoterol to treat large and small airways in asthma. Expert Opin Drug Deliv 2014; 11:1497-506. [PMID: 24921434 DOI: 10.1517/17425247.2014.928282] [Citation(s) in RCA: 66] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
INTRODUCTION Airway inflammation and remodelling in asthma occur in the large airways and also in the small airways. The small airways are those < 2 mm in diameter and are significant sites of chronic asthmatic inflammation. It is important, therefore, to target the small as well as the large airways in any strategy for effective treatment of this disease. AREAS COVERED The present review deals with the recently developed fixed dose drug combination of beclometasone dipropionate/formoterol fumarate that emits extrafine particles when delivered from an innovative dry powder inhaler (DPI), NEXThaler®. The aim is to present the technical and clinical aspects of aerosolized drug delivery to the lungs. EXPERT OPINION The data show that the NEXThaler DPI is an efficient device for the management of persistent asthma. The evaluation of the inhalation profiles through the NEXThaler DPI demonstrates that device activation and consistent dose delivery occurs at patient achievable inhalation flow rates, and supports the broad utility of the NEXThaler DPI in patients with asthma. Overall, all the effectiveness, efficiency and satisfaction outcomes demonstrate the NEXThaler DPI is easy to use.
Collapse
Affiliation(s)
- Massimo Corradi
- University of Parma, Department of Clinical and Experimental Medicine , Parma , Italy +0039 0521 033098 ; +0039 0521 033099 ;
| | | | | | | | | | | | | | | |
Collapse
|
92
|
Abstract
Drug delivery to the lungs is an effective way of targeting inhaled therapeutic aerosols and treating obstructive airway diseases, such as asthma and chronic obstructive pulmonary disease (COPD). In the past 10 years, several new drugs for the management of asthma and COPD have been marketed and more are under development. These new therapeutic respiratory drugs have been furthered by innovations in all categories of pulmonary drug delivery systems to ensure optimal aerosolisation performance, consistency in efficacy and satisfactory patient adherence. In this review, we discuss the technological advances and innovations in recent inhaler devices and the evolving roles of pressurised metered-dose inhalers, dry powder inhalers and nebulisers, as well as their impact on patient adherence to treatment.
Collapse
Affiliation(s)
- Federico Lavorini
- Department of Experimental and Clinical Medicine, Careggi University Hospital, Florence, Italy
| | | | | |
Collapse
|
93
|
Affiliation(s)
- Omar S Usmani
- National Heart and Lung Institute (NHLI), Imperial College London and Royal Brompton Hospital, London, UK
| |
Collapse
|
94
|
Paredi P, Kharitonov SA, Meah S, Barnes PJ, Usmani OS. A novel approach to partition central and peripheral airway nitric oxide. Chest 2014; 145:113-119. [PMID: 23989961 DOI: 10.1378/chest.13-0843] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
Abstract
BACKGROUND Determining the site of airways inflammation may lead to the targeting of therapy. Nitric oxide (NO) is a biomarker of airway inflammation and can be measured at multiple exhalation flow rates to allow partitioning into bronchial (large/central airway maximal nitric oxide flux [J'awno]) and peripheral (peripheral/small airway/alveolar nitric oxide concentration [Cano]) airway contributions by linear regression. This requires a minimum of three exhalations. We developed a simple and practical method to partition NO. METHODS In 29 healthy subjects (FEV1, 97% ± 3% predicted), 13 patients with asthma (FEV1, 90% ± 4% predicted), 14 patients with COPD (FEV1, 59% ± 3% predicted), and 12 patients with cystic fibrosis (CF) (FEV1, 60% ± 3% predicted), we measured the area under the curve of the NO concentration/exhalation time plot (AUC-NO) at exhalation flow rates of 50, 100, 200, and 300 mL/s. We determined the change of the total AUC-NO production (ΔAUC-NO) among the four different exhalation flow rates and compared these levels to Cano and J'awno indices measured conventionally by linear regression. RESULTS The change in AUC-NO between increasing exhalation flow rates of 50 to 200 mL/s (ΔAUC-NO50-200) was strongly correlated with J'awno in all patient groups as follows: healthy subjects (r = 0.94, P < .001), patients with asthma (r = 0.98, P < .001), patients with COPD (r = 0.93, P < .001), and patients with CF (r = 0.74, P < .05). In all subjects, AUC-NO at an exhalation flow rate of 200 mL/s (AUC-NO200) correlated with Cano (r = 0.69, P < .01). CONCLUSIONS The bronchial production of NO can be determined by measuring ΔAUC-NO50-200, whereas AUC-NO200 measures its peripheral concentration. This approach is simple, quick, and does not require sophisticated equipment or mathematical models.
Collapse
Affiliation(s)
- Paolo Paredi
- Airways Disease Section, National Heart and Lung Institute, Imperial College London and Royal Brompton Hospital, London, England.
| | - Sergei A Kharitonov
- Airways Disease Section, National Heart and Lung Institute, Imperial College London and Royal Brompton Hospital, London, England
| | - Sally Meah
- Airways Disease Section, National Heart and Lung Institute, Imperial College London and Royal Brompton Hospital, London, England
| | - Peter J Barnes
- Airways Disease Section, National Heart and Lung Institute, Imperial College London and Royal Brompton Hospital, London, England
| | - Omar S Usmani
- Airways Disease Section, National Heart and Lung Institute, Imperial College London and Royal Brompton Hospital, London, England
| |
Collapse
|
95
|
Hakim A, Barnes PJ, Adcock IM, Usmani OS. Importin‐7 mediates glucocorticoid receptor nuclear import and is impaired by oxidative stress, leading to glucocorticoid insensitivity. FASEB J 2013; 27:4510-9. [DOI: 10.1096/fj.12-222604] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Amir Hakim
- National Heart and Lung InstituteImperial College London and Royal Brompton HospitalLondonUK
| | - Peter J. Barnes
- National Heart and Lung InstituteImperial College London and Royal Brompton HospitalLondonUK
| | - Ian M. Adcock
- National Heart and Lung InstituteImperial College London and Royal Brompton HospitalLondonUK
| | - Omar S. Usmani
- National Heart and Lung InstituteImperial College London and Royal Brompton HospitalLondonUK
| |
Collapse
|
96
|
Bikov A, Paschalaki K, Logan-Sinclair R, Horváth I, Kharitonov SA, Barnes PJ, Usmani OS, Paredi P. Standardised exhaled breath collection for the measurement of exhaled volatile organic compounds by proton transfer reaction mass spectrometry. BMC Pulm Med 2013; 13:43. [PMID: 23837867 PMCID: PMC3708755 DOI: 10.1186/1471-2466-13-43] [Citation(s) in RCA: 53] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2013] [Accepted: 07/04/2013] [Indexed: 01/03/2023] Open
Abstract
Background Exhaled breath volatile organic compound (VOC) analysis for airway disease monitoring is promising. However, contrary to nitric oxide the method for exhaled breath collection has not yet been standardized and the effects of expiratory flow and breath-hold have not been sufficiently studied. These manoeuvres may also reveal the origin of exhaled compounds. Methods 15 healthy volunteers (34 ± 7 years) participated in the study. Subjects inhaled through their nose and exhaled immediately at two different flows (5 L/min and 10 L/min) into methylated polyethylene bags. In addition, the effect of a 20 s breath-hold following inhalation to total lung capacity was studied. The samples were analyzed for ethanol and acetone levels immediately using proton-transfer-reaction mass-spectrometer (PTR-MS, Logan Research, UK). Results Ethanol levels were negatively affected by expiratory flow rate (232.70 ± 33.50 ppb vs. 202.30 ± 27.28 ppb at 5 L/min and 10 L/min, respectively, p < 0.05), but remained unchanged following the breath hold (242.50 ± 34.53 vs. 237.90 ± 35.86 ppb, without and with breath hold, respectively, p = 0.11). On the contrary, acetone levels were increased following breath hold (1.50 ± 0.18 ppm) compared to the baseline levels (1.38 ± 0.15 ppm), but were not affected by expiratory flow (1.40 ± 0.14 ppm vs. 1.49 ± 0.14 ppm, 5 L/min vs. 10 L/min, respectively, p = 0.14). The diet had no significant effects on the gasses levels which showed good inter and intra session reproducibility. Conclusions Exhalation parameters such as expiratory flow and breath-hold may affect VOC levels significantly; therefore standardisation of exhaled VOC measurements is mandatory. Our preliminary results suggest a different origin in the respiratory tract for these two gasses.
Collapse
|
97
|
Hakim A, Adcock IM, Usmani OS. Corticosteroid resistance and novel anti-inflammatory therapies in chronic obstructive pulmonary disease: current evidence and future direction. Drugs 2012; 72:1299-312. [PMID: 22731962 DOI: 10.2165/11634350-000000000-00000] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Corticosteroids are widely used in the treatment of chronic obstructive pulmonary disease (COPD). However, in contrast to their use in mild-to-moderate asthma, they are much less effective in enhancing lung function and have little or no effect on controlling the underlying chronic inflammation. In most clinical trials in COPD patients, corticosteroids have shown little benefit as monotherapy, but have shown a greater clinical effect in combination with long-acting bronchodilators. Several mechanisms of corticosteroid resistance have been postulated, including a reduction in histone deacetylase (HDAC)-2 activity and expression, impaired corticosteroid activation of the glucocorticoid receptor (GR) and increased pro-inflammatory signalling pathways. Reversal of corticosteroid resistance in COPD patients by restoring HDAC2 levels has proved effective in a small study, and long-term studies are needed to determine whether novel HDAC2 activators or theophylline improve disease progression, exacerbations or mortality. Advances in the understanding of the cellular and molecular mechanisms of corticosteroid resistance in COPD pathophysiology have supported the development of new emerging classes of anti-inflammatory drugs in COPD treatment. These include treatments such as inhibitors of phosphoinositide-3-kinase-delta (PI3Kδ), phosphodiesterase-4 (PDE4), p38 mitogen-activated protein kinase (MAPK) and nuclear factor kappa B (NF-κB), and therapeutic agents such as chemokine receptor antagonists. Of these, PI3Kδ, PDE4, p38 MAPK inhibitors and chemokine receptor antagonists are in clinical patient trials. Of importance, patient adverse effects associated with oral administration of these novel agents needs to be addressed in order to optimize therapy and patient compliance. Combinations of these drugs with corticosteroids may have additional benefits.
Collapse
Affiliation(s)
- Amir Hakim
- National Heart and Lung Institute, Imperial College London and Royal Brompton Hospital, London, UK
| | | | | |
Collapse
|
98
|
Newman S, Bennett WD, Biddiscombe M, Devadason SG, Dolovich MB, Fleming J, Haeussermann S, Kietzig C, Kuehl PJ, Laube BL, Sommerer K, Taylor G, Usmani OS, Zeman KL. Standardization of Techniques for Using Planar (2D) Imaging for Aerosol Deposition Assessment of Orally Inhaled Products. J Aerosol Med Pulm Drug Deliv 2012; 25 Suppl 1:S10-28. [DOI: 10.1089/jamp.2012.1su4] [Citation(s) in RCA: 78] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
- Stephen Newman
- Scientific Consultant, Hunstanton, Norfolk, United Kingdom
| | - William D. Bennett
- Department of Medicine, Department of Pulmonary Disease, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina
| | - Martyn Biddiscombe
- Nuclear Medicine Department, Royal Brompton Hospital, Sydney Street, London, United Kingdom
| | - Sunalene G. Devadason
- School of Paediatrics and Child Health, University of Western Australia, Perth, Western Australia, Australia
| | - Myrna B. Dolovich
- Faculty of Sciences, Michael de Groote School of Medicine, McMaster University, Hamilton, Ontario, Canada
| | - John Fleming
- University Hospital Southampton NHS Foundation Trust, Southampton, United Kingdom
| | | | | | - Philip J. Kuehl
- Lovelace Respiratory Research Institute, Albuquerque, New Mexico
| | - Beth L. Laube
- Johns Hopkins University School of Medicine, Baltimore, Maryland
| | | | - Glyn Taylor
- Cardiff Scintigraphics and Welsh School of Pharmacy, Cardiff, United Kingdom
| | - Omar S. Usmani
- Airway Disease Section, National Heart and Lung Institute, Imperial College London and Royal Brompton Hospital, London, United Kingdom
| | - Kirby L. Zeman
- Center for Environmental Medicine, Asthma and Lung Biology, University of North Carolina, Chapel Hill, North Carolina
| |
Collapse
|
99
|
Abstract
The final article in this series evaluates the approaches undertaken to treating the small-airway region of the lungs and the clinical implications of inhaled therapy targeting the periphery in patients with asthma and chronic obstructive pulmonary disease.
Collapse
Affiliation(s)
- Omar S Usmani
- Airway Disease Section, National Heart and Lung Institute, Imperial College London, and Royal Brompton Hospital, London, UK.
| |
Collapse
|
100
|
Mercado N, Hakim A, Kobayashi Y, Meah S, Usmani OS, Chung KF, Barnes PJ, Ito K. Restoration of corticosteroid sensitivity by p38 mitogen activated protein kinase inhibition in peripheral blood mononuclear cells from severe asthma. PLoS One 2012; 7:e41582. [PMID: 22911818 PMCID: PMC3402424 DOI: 10.1371/journal.pone.0041582] [Citation(s) in RCA: 91] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2012] [Accepted: 06/27/2012] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND Severe asthma accounts for a small number of asthmatics but represents a disproportionate cost to health care systems. The underlying mechanism in severe asthma remains unknown but several mechanisms are likely to be involved because of a very heterogeneous profile. We investigated the effects of a p38MAPK inhibitor in corticosteroid sensitivity in peripheral blood mononuclear cells (PBMCs) from severe asthmatics and the profile of its responders. METHODOLOGY/PRINCIPAL FINDINGS Corticosteroid sensitivity was determined by measuring dexamethasone inhibition of CD3/28 and TNF-α induced IL-8 production in PBMCs by using ELISA. PBMCs from severe asthmatics were relatively less sensitive to dexamethasone (Dex) as compared to those of non-severe asthmatics and healthy volunteers. The IC(50) values of Dex negatively correlated with decreased glucocorticoid receptor (GR) nuclear translocation assessed using immunocytochemistry (r = -0.65; p<0.0005) and with decreased FEV(1) (% predicted) (r = 0.6; p<0.0005). A p38α/β inhibitor (SB203580) restored Dex-sensitivity in a subpopulation of severe asthma that was characterized by a defective GR nuclear translocation, clinically by lower FEV(1) and higher use of oral prednisolone. We also found that SB203580 partially inhibited GR phosphorylation at serine 226, resulting in increased GR nuclear translocation in IL-2/IL-4 treated corticosteroid insensitive U937s. CONCLUSIONS/SIGNIFICANCE p38MAPKα/β is involved in defective GR nuclear translocation due to phosphorylation at Ser226 and this will be a useful biomarker to identify responders to p38MAPKα/β inhibitor in the future.
Collapse
Affiliation(s)
- Nicolas Mercado
- Airway Disease Section, National Heart and Lung Institute, Imperial College, London, United Kingdom
| | - Amir Hakim
- Airway Disease Section, National Heart and Lung Institute, Imperial College, London, United Kingdom
- Biomedical Research Unit, Royal Brompton Hospital and Imperial College, London, United Kingdom
| | - Yoshiki Kobayashi
- Airway Disease Section, National Heart and Lung Institute, Imperial College, London, United Kingdom
| | - Sally Meah
- Airway Disease Section, National Heart and Lung Institute, Imperial College, London, United Kingdom
- Biomedical Research Unit, Royal Brompton Hospital and Imperial College, London, United Kingdom
| | - Omar S. Usmani
- Airway Disease Section, National Heart and Lung Institute, Imperial College, London, United Kingdom
- Biomedical Research Unit, Royal Brompton Hospital and Imperial College, London, United Kingdom
| | - Kian Fan Chung
- Airway Disease Section, National Heart and Lung Institute, Imperial College, London, United Kingdom
- Biomedical Research Unit, Royal Brompton Hospital and Imperial College, London, United Kingdom
| | - Peter J. Barnes
- Airway Disease Section, National Heart and Lung Institute, Imperial College, London, United Kingdom
| | - Kazuhiro Ito
- Airway Disease Section, National Heart and Lung Institute, Imperial College, London, United Kingdom
| |
Collapse
|