26
|
Sharma AK, Kalonia A, Kumar R, Kirti, Shaw P, Yashvarddhan MH, Vibhuti A, Shukla SK. Alleviation of radiation combined skin injury in rat model by topical application of ascorbate formulation. Int J Radiat Biol 2024; 100:689-708. [PMID: 38306495 DOI: 10.1080/09553002.2024.2310016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Accepted: 01/22/2024] [Indexed: 02/04/2024]
Abstract
PURPOSE This research endeavor was undertaken to elucidate the impact of an innovative ascorbate formulation on the regeneration process of full-thickness excision wounds in a rat model exposed to whole-body gamma irradiation, replicating conditions akin to combat or radiation emergency scenarios. MATERIALS AND METHODS We established a comprehensive rat model by optimizing whole body γ-radiation doses (5-9 Gy) and full-thickness excision wound sizes (1-3 cm2) to mimic radiation combined injury (RCI). The developed RCI model was used to explore the healing potential of ascorbate formulation. The study includes various treatment groups (i.e., sham control, radiation alone, wound alone, radiation + wound, and radiation + wound + formulation). The ascorbate formulation was applied twice daily, with a 12-hour gap between each application, starting 1 hour after the initiation of the wound. The healing potential of the formulation in the RCI context was evaluated over 14 days through hematological, molecular, and histological parameters. RESULTS The combination of a 5 Gy radiation dose and a 1 cm2 wound was identified as the optimal setting to develop the RCI model for subsequent studies. The formulation was used topically immediately following RCI, and then twice daily until complete healing. Treatment with the ascorbate formulation yielded noteworthy outcomes and led to a substantial reduction (p < .05) in the wound area, accelerated epithelialization periods, and an increased wound contraction rate. The formulation's localized healing response improved organ weights, normalized blood parameters, and enhanced hematopoietic and immune systems. A gene expression study revealed the treatment up-regulated TGF-β and FGF, and down-regulated PDGF-α, TNF-α, IL-1β, IL-6, MIP-1α, and MCP-1 (p < .05). Histopathological assessments supported the formulation's effectiveness in restoring cellular architecture and promoting tissue regeneration. CONCLUSION Topical application of the ascorbate formulation in RCI resulted in a significant improvement in delayed wound healing, leading to accelerated wound closure by mitigating the expression of inflammatory responses.
Collapse
|
27
|
Zaman MU. Comparing Radiation Doses in CBCT and Medical CT Imaging for Dental Applications. JOURNAL OF PHARMACY AND BIOALLIED SCIENCES 2024; 16:S883-S885. [PMID: 38595575 PMCID: PMC11001137 DOI: 10.4103/jpbs.jpbs_1077_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Revised: 10/21/2023] [Accepted: 10/23/2023] [Indexed: 04/11/2024] Open
Abstract
Background We are always concerned about radiation exposure during dental imaging procedures. We explore the crucial differences in radiation doses between Cone Beam Computed Tomography (CBCT) and Medical computed tomography (CT) imaging, aiming to shed light on the safety and efficiency of these techniques. Materials and Methods In this study, we conducted a comprehensive analysis using state-of-the-art dental imaging equipment. We employed phantoms that simulated real dental scenarios, ensuring accuracy in our measurements. The radiation doses were measured with precision dosimeters, and various exposure settings were tested to obtain a comprehensive dataset. Results Our findings reveal substantial differences in radiation doses between CBCT and Medical CT for dental applications. In the case of CBCT, the average effective dose was found to be approximately 100 microsieverts (μSv), making it a preferable choice for routine dental imaging. Medical CT, on the other hand, yielded significantly higher radiation exposure, with an average effective dose exceeding 500 μSv, emphasizing its need for specific clinical scenarios. Conclusion In conclusion, the choice between CBCT and Medical CT for dental applications should be made with careful consideration of radiation dose implications. CBCT emerges as the safer and more efficient option for routine dental imaging, offering a lower radiation burden to patients while still delivering high-quality diagnostic images. However, Medical CT may be necessary for specialized cases where the additional radiation risk is justified by diagnostic requirements.
Collapse
|
28
|
Tian X, Chang Z, Dilixiati S, Haimiti Y, Wang S, Sun J. Optimizing image quality and minimizing radiation dose in pediatric abdominal multiphase contrast-enhanced computed tomography: a study on CARE kV and CARE Dose 4D. Quant Imaging Med Surg 2024; 14:1985-1993. [PMID: 38415123 PMCID: PMC10895141 DOI: 10.21037/qims-23-1181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2023] [Accepted: 12/14/2023] [Indexed: 02/29/2024]
Abstract
Background Multiphase contrast-enhanced computed tomography (CECT) is a commonly used modality in pediatric computed tomography (CT) scans. However, the purposes and focus of each phase, such as CT angiography (CTA), and parenchymal phase, are different. In routine practice, the same scanning parameters are used for all phases, resulting in unnecessary radiation exposure for children. Accurately and rapidly adjusting the scanning parameters for each phase of CECT is challenging in clinical settings. This retrospective cross-sectional study was designed to investigate the feasibility of using both CARE kV and CARE Dose 4D to reduce the radiation dose while maintaining diagnostic quality in multiphase CECT scans of children. Methods Overall, 57 children (33 males and 24 females) who underwent multiphase abdominal CECT in Xinjiang Hospital of Beijing Children's Hospital with an average age of 6.52±4.30 years (range, 0.1-15 years), were enrolled. The tube voltage was automatically modulated using CARE kV. The tube current was automatically modulated using CARE Dose 4D. Different dose saving optimization indices (DI) were used for the three phases: a DI value of 3 was used for the unenhanced CT phase, a DI value of 12 was used for the CTA phase, and a DI value of 7 was used for the parenchymal phase. The tube voltage and volume CT dose index (CTDIvol) were recorded for each phase. Two reviewers subjectively evaluated the overall image quality and noise level of the three phases using a 5-point Likert scale (1-2 points: unqualified, 3 points: qualified, 4 points: better, 5 points: best). The CT and noise values of the descending aorta, liver, and back muscle were measured objectively. The voltage distribution and the image quality and CTDIvol in each phase were compared. Results The most selected tube voltage in the unenhanced CT, CTA, and parenchymal phases was 100 kV (49/57, 85.96%), 70 kV (36/57, 63.16%), and 80 kV (32/57, 56.14%), respectively. The differences between the three phases were statistically significant (P<0.001). The CTDIvol values of the three phases were 3.99±1.99, 2.02±1.71, and 3.18±2.10 mGy, respectively, with a significant difference between the three phases (P<0.001). The CTDIvol decreased linearly as the DI value increased. All images met the diagnostic requirements. The overall quality scores for the three phases were 4.24±0.42, 4.41±0.49, and 4.50±0.45, respectively, with no significant linear relationship with the change in the DI. Conclusions The combined use of CARE Dose 4D and CARE kV could effectively reduce the radiation dose in children during multiphase abdominal CECT without compromising the diagnostic image quality.
Collapse
|
29
|
Sawyer MD, Kiani K, Stickel JR, Ballon-Landa EC. Gel Rolls Increase Percutaneous Nephrolithotomy Radiation Exposure. J Endourol 2024; 38:16-22. [PMID: 37917095 DOI: 10.1089/end.2023.0251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2023] Open
Abstract
Introduction: Despite increasing interest in reducing radiation doses during endoscopic stone surgery, there is conflicting evidence as to whether percutaneous nephrolithotomy (PCNL) positioning (prone or supine) impacts radiation. We observed clinically that a patient placed prone on gel rolls had higher than expected radiation with intraoperative CT imaging and that gel rolls were visible on the coaxial imaging. We hypothesized that gel rolls directly increase radiation doses. Methods: Anthropomorphic experiments to simulate PCNL positions were performed using a robotic multiplanar fluoroscopy system (Artis Zeego Care+Clear, Siemens) and a 5-second coaxial imaging protocol (5s BODY). A fluoroscopy phantom was placed in various positions, including prone on a gel roll; prone on blankets of equal thickness; prone and supine directly on the table; and modified supine (MS) positions using a thin gel roll or rolled blanket. Impacts of C-arm direction and use of a 1 L saline bag were also evaluated. Measured dose area product (DAP) was compared for the groups. Results: Measured DAP was found to increase by 146 μGy*m2 (287%) when prone on gel rolls compared with only 62.29 (23%) when placed on blankets of equal thickness, although the model likely both overstates the relative impact and understates the absolute impact that would be seen clinically. Measured DAP between experimental groups also varied considerably despite fluoroscopy time being held constant. Conclusions: Our experiments support our hypothesis that gel rolls directly increase radiation dose, which has not been previously reported, using an anthropomorphic model. Surgeons should consider radiolucent materials for positioning to limit radiation exposure to patients and the surgical team.
Collapse
|
30
|
Tonkopi E, Tetteh MA, Gunn C, Ashraf H, Rusten SL, Safi P, Tinsoe NS, Colford K, Ouellet O, Naimi S, Johansen S. A multi-institutional assessment of low-dose protocols in chest computed tomography: Dose and image quality. Acta Radiol Open 2024; 13:20584601241228220. [PMID: 38304118 PMCID: PMC10829498 DOI: 10.1177/20584601241228220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2023] [Accepted: 01/09/2024] [Indexed: 02/03/2024] Open
Abstract
Background Low-dose CT (LDCT) chest protocols have widespread clinical applications for many indications; as a result, there is a need for protocol assessment prior to standardization. Dalhousie University and Oslo Metropolitan University have a formally established cooperative relationship. Purpose The purpose is to assess radiation dose and image quality for LDCT chest protocols in seven different hospital locations in Norway and Canada. Material and methods Retrospective dosimetry data, volumetric CT dose index (CTDIvol), and dose length product (DLP) from 240 average-sized patients as well as CT protocol parameters were included in the survey. Effective dose (ED) and size-specific dose estimate (SSDE) were calculated for each examination. For a quantitative image quality analysis, noise, CT number, and signal-to-noise ratio (SNR) were determined for three regions in the chest. The contrast-to-noise ratio (CNR) was calculated for lung parenchyma in comparison to the subcutaneous fat. Differences in dose and image quality were evaluated by a single-factor ANOVA test. A two-sample t-test was performed to determine differences in means between individual scanners. Results The ANOVA test revealed significant differences (p < .05) in dose values for all scanners, including identical scanner models. Statistically significant differences (p < .05) were determined in mean values of the SNR distributions between the scanners in all three measured regions in the chest, as well as the CNR values. Conclusion The observed variations in dose and image quality measurements, even within the same hospitals and between identical scanner models, indicate a potential for protocol optimization in the involved hospitals in both countries.
Collapse
|
31
|
Rawashdeh M, Bani Yaseen AB, McEntee M, England A, Kumar P, Saade C. Diagnostic reference levels in spinal CT: Jordanian assessments and global benchmarks. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2024; 32:725-734. [PMID: 38189739 DOI: 10.3233/xst-230276] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2024]
Abstract
BACKGROUND To reduce radiation dose and subsequent risks, several legislative documents in different countries describe the need for Diagnostic Reference Levels (DRLs). Spinal radiography is a common and high-dose examination. Therefore, the aim of this work was to establish the DRL for Computed Tomography (CT) examinations of the spine in healthcare institutions across Jordan. METHODS Data was retrieved from the picture archiving and communications system (PACS), which included the CT Dose Index (CTDI (vol) ) and Dose Length Product (DLP). The median radiation dose values of the dosimetric indices were calculated for each site. DRL values were defined as the 75th percentile distribution of the median CTDI (vol) and DLP values. RESULTS Data was collected from 659 CT examinations (316 cervical spine and 343 lumbar-sacral spine). Of the participants, 68% were males, and the patients' mean weight was 69.7 kg (minimum = 60; maximum = 80, SD = 8.9). The 75th percentile for the DLP of cervical and LS-spine CT scans in Jordan were 565.2 and 967.7 mGy.cm, respectively. CONCLUSIONS This research demonstrates a wide range of variability in CTDI (vol) and DLP values for spinal CT examinations; these variations were associated with the acquisition protocol and highlight the need to optimize radiation dose in spinal CT examinations.
Collapse
|
32
|
Gao K, Ma ZP, Zhang TL, Liu YW, Zhao YX. Comparative study of abdominal CT enhancement in overweight and obese patients based on different scanning modes combined with different contrast medium concentrations. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY 2024; 32:569-581. [PMID: 38217636 DOI: 10.3233/xst-230327] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/15/2024]
Abstract
PURPOSE To compare image quality, iodine intake, and radiation dose in overweight and obese patients undergoing abdominal computed tomography (CT) enhancement using different scanning modes and contrast medium. METHODS Ninety overweight and obese patients (25 kg/m2≤body mass index (BMI)< 30 kg/m2 and BMI≥30 kg/m2) who underwent abdominal CT-enhanced examinations were randomized into three groups (A, B, and C) of 30 each and scanned using gemstone spectral imaging (GSI) +320 mgI/ml, 100 kVp + 370 mgI/ml, and 120 kVp + 370 mgI/ml, respectively. Reconstruct monochromatic energy images of group A at 50-70 keV (5 keV interval). The iodine intake and radiation dose of each group were recorded and calculated. The CT values, contrast-to-noise ratios (CNRs), and subjective scores of each subgroup image in group A versus images in groups B and C were by using one-way analysis of variance or Kruskal-Wallis H test, and the optimal keV of group A was selected. RESULTS The dual-phase CT values and CNRs of each part in group A were higher than or similar to those in groups B and C at 50-60 keV, and similar to or lower than those in groups B and C at 65 keV and 70 keV. The subjective scores of the dual-phase images in group A were lower than those of groups B and C at 50 keV and 55 keV, whereas no significant difference was seen at 60-70 keV. Compared to groups B and C, the iodine intake in group A decreased by 12.5% and 13.3%, respectively. The effective doses in groups A and B were 24.7% and 25.8% lower than those in group C, respectively. CONCLUSION GSI +320 mgI/ml for abdominal CT-enhanced in overweight patients satisfies image quality while reducing iodine intake and radiation dose, and the optimal keV was 60 keV.
Collapse
|
33
|
Kang HJ, Lee JM, Park SJ, Lee SM, Joo I, Yoon JH. Image Quality Improvement of Low-dose Abdominal CT using Deep Learning Image Reconstruction Compared with the Second Generation Iterative Reconstruction. Curr Med Imaging 2024; 20:e250523217310. [PMID: 37231764 DOI: 10.2174/1573405620666230525104809] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 03/23/2023] [Accepted: 04/06/2023] [Indexed: 05/27/2023]
Abstract
BACKGROUND Whether deep learning-based CT reconstruction could improve lesion conspicuity on abdominal CT when the radiation dose is reduced is controversial. OBJECTIVES To determine whether DLIR can provide better image quality and reduce radiation dose in contrast-enhanced abdominal CT compared with the second generation of adaptive statistical iterative reconstruction (ASiR-V). AIMS This study aims to determine whether deep-learning image reconstruction (DLIR) can improve image quality. METHOD In this retrospective study, a total of 102 patients were included, who underwent abdominal CT using a DLIR-equipped 256-row scanner and routine CT of the same protocol on the same vendor's 64-row scanner within four months. The CT data from the 256-row scanner were reconstructed into ASiR-V with three blending levels (AV30, AV60, and AV100), and DLIR images with three strength levels (DLIR-L, DLIR-M, and DLIR-H). The routine CT data were reconstructed into AV30, AV60, and AV100. The contrast-to-noise ratio (CNR) of the liver, overall image quality, subjective noise, lesion conspicuity, and plasticity in the portal venous phase (PVP) of ASiR-V from both scanners and DLIR were compared. RESULTS The mean effective radiation dose of PVP of the 256-row scanner was significantly lower than that of the routine CT (6.3±2.0 mSv vs. 2.4±0.6 mSv; p< 0.001). The mean CNR, image quality, subjective noise, and lesion conspicuity of ASiR-V images of the 256-row scanner were significantly lower than those of ASiR-V images at the same blending factor of routine CT, but significantly improved with DLIR algorithms. DLIR-H showed higher CNR, better image quality, and subjective noise than AV30 from routine CT, whereas plasticity was significantly better for AV30. CONCLUSION DLIR can be used for improving image quality and reducing radiation dose in abdominal CT, compared with ASIR-V.
Collapse
|
34
|
Ma Y, Fu B, Yu A, Yang Y, Rajiah PS, Zhang H. Feasibility study of using low-kilovoltage, prospective gating, high-pitch, dual-source computed tomography prior to transcatheter aortic valve replacement: analysis of image quality and radiation dose. J Thorac Dis 2023; 15:6848-6857. [PMID: 38249861 PMCID: PMC10797387 DOI: 10.21037/jtd-23-1734] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Accepted: 12/13/2023] [Indexed: 01/23/2024]
Abstract
Background Computed tomography (CT) scans before transcatheter aortic valve replacement (TAVR) are used to evaluate the aortic valve and guide the selection of appropriate valve stents. Accurate imaging evaluation can ensure the success rate of surgery while reducing the incidence of complications. Multiple studies have adopted a protocol of coronary artery, aortic valve, and total aortic scan, with the patients receiving higher radiation doses. The aim of this study was to evaluate the image quality, radiation dose, and diagnostic performance of dual-source computed tomography (DSCT) with high-pitch spiral scanning for TAVR. Methods A total of 240 patients being evaluated for TAVR were continuously enrolled. Based on the differences in electrocardiography (ECG) gating and tube voltage, the patients were divided into 4 groups: group A, 70-kV prospective ECG gating, high-pitch helical; group B, 70-kV retrospective ECG gating; group C, 100-kV prospective ECG gating, high-pitch helical; and group D, 120-kV prospective ECG gating, high-pitch helical. Image quality was evaluated on a 4-point scale. The image signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated for objective evaluation. The radiation doses of all patients were recorded. The image quality and radiation dose of each group were compared. Results There were no differences in age, body mass index (BMI), subjective image quality scores, CT values between the aorta and the coronary artery, or image CNR between the 4 groups. The mean radiation doses of groups A-D were 4.13±0.69, 4.79±0.58, 12.00±1.62, and 15.01±1.90 mSv, respectively. The mean radiation dose in group A (70-kV prospective ECG gating) decreased significantly (P<0.05). Conclusions Using low-kilovoltage, high-pitch DSCT can provide comparable image quality for TAVR evaluation and significantly reduce the radiation dose.
Collapse
|
35
|
Agadakos E, Zormpala A, Zaios N, Kapsiocha C, Gamaletsou MN, Voulgarelis M, Sipsas NV, Moulopoulos LA, Koutoulidis V. The Use of Low-Dose Chest Computed Tomography for the Diagnosis and Monitoring of Pulmonary Infections in Patients with Hematologic Malignancies. Cancers (Basel) 2023; 16:186. [PMID: 38201613 PMCID: PMC10778314 DOI: 10.3390/cancers16010186] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 12/26/2023] [Accepted: 12/27/2023] [Indexed: 01/12/2024] Open
Abstract
The study aimed to assess the image quality and diagnostic performance of low-dose Chest Computed Tomography (LDCCT) in detecting pulmonary infections in patients with hematologic malignancies. A total of 164 neutropenic patients underwent 256 consecutive CT examinations, comparing 149 LDCCT and 107 Standard-Dose Chest CT (SDCCT) between May 2015 and June 2019. LDCCT demonstrated a 47% reduction in radiation dose while maintaining acceptable image noise and quality compared to SDCCT. However, LDCCT exhibited lower sensitivity in detecting consolidation (27.5%) and ground glass opacity (64.4%) compared to SDCCT (45.8% and 82.2%, respectively) with all the respective p-values from unadjusted and adjusted for sex, age, and BMI analyses being lower than 0.006 and the corresponding Odds Ratios of detection ranging from 0.30 to 0.34. Similar trends were observed for nodules ≥3 mm and ground glass halo in nodules but were not affected by sex, age and BMI. No significant differences were found for cavitation in nodules, diffuse interlobular septal thickening, pleural effusion, pericardial effusion, and lymphadenopathy. In conclusion, LDCCT achieved substantial dose reduction with satisfactory image quality but showed limitations in detecting specific radiologic findings associated with pulmonary infections in neutropenic patients compared to SDCCT.
Collapse
|
36
|
Inoue Y, Mori M, Itoh H, Mitsui K, Miyatake H, Yamane T, Hata H. Age-Dependent Changes in Effective Dose in Pediatric Brain CT: Comparisons of Estimation Methods. Tomography 2023; 10:14-24. [PMID: 38250948 PMCID: PMC10821001 DOI: 10.3390/tomography10010002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2023] [Revised: 12/20/2023] [Accepted: 12/21/2023] [Indexed: 01/23/2024] Open
Abstract
The effective dose (ED) in computed tomography (CT) may be calculated by multiplying the dose-length product (DLP) by a conversion factor. As children grow, automatic exposure control increases the DLP, while the conversion factor decreases; these two changes affect the ED in opposite ways. The aim of this study was to investigate the methods of ED estimation according to age in pediatric brain CT. We retrospectively analyzed 980 brain CT scans performed for various clinical indications in children. The conversion factor at each age, in integer years, was determined based on the values at 0, 1, 5, and 10 years provided by the International Commission on Radiological Protection (ICRP), using a curve (curve method) or lines (linear method). In the simple method, the ED was estimated using the ICRP conversion factor for the closest age. We also analyzed the ED estimated by a radiation dose management system. Although the median DLP at each age increased with age, the median ED estimated by the curve method was highest at 0 years, decreased with age, and then plateaued at 9 years. The linear method yielded mildly different results, especially at 2 and 3 years. The ED estimated by the simple method or the radiation dose management system showed inconsistent, up-and-down changes with age. In conclusion, the ED in pediatric brain CT decreases with age despite increased DLP. Determination of the conversion factor at each age using a curve is expected to contribute to estimating the ED in pediatric CT according to age.
Collapse
|
37
|
Abdelaziz RF, Hussein AM, Kotob MH, Weiss C, Chelminski K, Stojanovic T, Studenik CR, Aufy M. Enhancement of Radiation Sensitivity by Cathepsin L Suppression in Colon Carcinoma Cells. Int J Mol Sci 2023; 24:17106. [PMID: 38069428 PMCID: PMC10707098 DOI: 10.3390/ijms242317106] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2023] [Revised: 11/30/2023] [Accepted: 12/01/2023] [Indexed: 12/18/2023] Open
Abstract
Cancer is one of the main causes of death globally. Radiotherapy/Radiation therapy (RT) is one of the most common and effective cancer treatments. RT utilizes high-energy radiation to damage the DNA of cancer cells, leading to their death or impairing their proliferation. However, radiation resistance remains a significant challenge in cancer treatment, limiting its efficacy. Emerging evidence suggests that cathepsin L (cath L) contributes to radiation resistance through multiple mechanisms. In this study, we investigated the role of cath L, a member of the cysteine cathepsins (caths) in radiation sensitivity, and the potential reduction in radiation resistance by using the specific cath L inhibitor (Z-FY(tBu)DMK) or by knocking out cath L with CRISPR/Cas9 in colon carcinoma cells (caco-2). Cells were treated with different doses of radiation (2, 4, 6, 8, and 10), dose rate 3 Gy/min. In addition, the study conducted protein expression analysis by western blot and immunofluorescence assay, cytotoxicity MTT, and apoptosis assays. The results demonstrated that cath L was upregulated in response to radiation treatment, compared to non-irradiated cells. In addition, inhibiting or knocking out cath L led to increased radiosensitivity in contrast to the negative control group. This may indicate a reduced ability of cancer cells to recover from radiation-induced DNA damage, resulting in enhanced cell death. These findings highlight the possibility of targeting cath L as a therapeutic strategy to enhance the effectiveness of RT. Further studies are needed to elucidate the underlying molecular mechanisms and to assess the translational implications of cath L knockout in clinical settings. Ultimately, these findings may contribute to the development of novel treatment approaches for improving outcomes of RT in cancer patients.
Collapse
|
38
|
Azcurra P, Leyton F, Lucini V, Rivarola M, Trentacoste L, Marques A, Chiabrando J, Seropian I, Mundo N, Ubeda C, Agatiello C. Local Diagnostic Reference Levels for Pediatric Interventional Cardiology Procedures in Argentina. CHILDREN (BASEL, SWITZERLAND) 2023; 10:1877. [PMID: 38136079 PMCID: PMC10741962 DOI: 10.3390/children10121877] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2023] [Revised: 11/02/2023] [Accepted: 11/24/2023] [Indexed: 12/24/2023]
Abstract
The aim of this work was to propose a preliminary local diagnostic reference levels (DRL) for pediatric interventional cardiology (PIC) procedures in Argentina, for different ranges of age and weight. This work has been conducted in the framework of the "Optimization of Protection in Pediatric Interventional Radiology in Latin America and the Caribbean" (OPRIPALC) program coordinated by the World Health Organization and the Pan American Health Organization in cooperation with the International Atomic Energy Agency to ensuring that radiation exposures of pediatric patients are the minimum necessary during fluoroscopy-guided interventional procedures. The local DRL values presented in this paper by weight group and age group were 7.1 Gy·cm2 (<5 kg), 10.7 Gy·cm2 (5-15 kg), 18.0 Gy·cm2 (15-30 kg), 15.9 Gy·cm2 (30-50 kg), and 28.2 Gy·cm2 (50-80 kg) and 5.3 Gy·cm2 (<1), 11.2 Gy·cm2 (1 to 5<), 19.6 Gy·cm2 (5 to 10<), and 21.4 Gy·cm2 (10 to 16<), respectively. Our dose results are among the values found in other international studies; however, there is great potential for dose optimization.
Collapse
|
39
|
Prabsattroo T, Wachirasirikul K, Tansangworn P, Punikhom P, Sudchai W. The Dose Optimization and Evaluation of Image Quality in the Adult Brain Protocols of Multi-Slice Computed Tomography: A Phantom Study. J Imaging 2023; 9:264. [PMID: 38132682 PMCID: PMC10743697 DOI: 10.3390/jimaging9120264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 11/23/2023] [Accepted: 11/24/2023] [Indexed: 12/23/2023] Open
Abstract
Computed tomography examinations have caused high radiation doses for patients, especially for CT scans of the brain. This study aimed to optimize the radiation dose and image quality in adult brain CT protocols. Images were acquired using a Catphan 700 phantom. Radiation doses were recorded as CTDIvol and dose length product (DLP). CT brain protocols were optimized by varying parameters such as kVp, mAs, signal-to-noise ratio (SNR) level, and Clearview iterative reconstruction (IR). The image quality was also evaluated using AutoQA Plus v.1.8.7.0 software. CT number accuracy and linearity had a robust positive correlation with the linear attenuation coefficient (µ) and showed more inaccurate CT numbers when using 80 kVp. The modulation transfer function (MTF) showed a higher value in 100 and 120 kVp protocols (p < 0.001), while high-contrast spatial resolution showed a higher value in 80 and 100 kVp protocols (p < 0.001). Low-contrast detectability and the contrast-to-noise ratio (CNR) tended to increase when using high mAs, SNR, and the Clearview IR protocol. Noise decreased when using a high radiation dose and a high percentage of Clearview IR. CTDIvol and DLP were increased with increasing kVp, mAs, and SNR levels, while the increasing percentage of Clearview did not affect the radiation dose. Optimized protocols, including radiation dose and image quality, should be evaluated to preserve diagnostic capability. The recommended parameter settings include kVp set between 100 and 120 kVp, mAs ranging from 200 to 300 mAs, SNR level within the range of 0.7-1.0, and an iterative reconstruction value of 30% Clearview to 60% or higher.
Collapse
|
40
|
Chan RCK, Ng CKC, Hung RHM, Li YTY, Tam YTY, Wong BYL, Yu JCK, Leung VWS. Comparative Study of Plan Robustness for Breast Radiotherapy: Volumetric Modulated Arc Therapy Plans with Robust Optimization versus Manual Flash Approach. Diagnostics (Basel) 2023; 13:3395. [PMID: 37998531 PMCID: PMC10670672 DOI: 10.3390/diagnostics13223395] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 11/03/2023] [Accepted: 11/04/2023] [Indexed: 11/25/2023] Open
Abstract
A previous study investigated robustness of manual flash (MF) and robust optimized (RO) volumetric modulated arc therapy plans for breast radiotherapy based on five patients in 2020 and indicated that the RO was more robust than the MF, although the MF is still current standard practice. The purpose of this study was to compare their plan robustness in terms of dose variation to clinical target volume (CTV) and organs at risk (OARs) based on a larger sample size. This was a retrospective study involving 34 female patients. Their plan robustness was evaluated based on measured volume/dose difference between nominal and worst scenarios (ΔV/ΔD) for each CTV and OARs parameter, with a smaller difference representing greater robustness. Paired sample t-test was used to compare their robustness values. All parameters (except CTV ΔD98%) of the RO approach had smaller ΔV/ΔD values than those of the MF. Also, the RO approach had statistically significantly smaller ΔV/ΔD values (p < 0.001-0.012) for all CTV parameters except the CTV ΔV95% and ΔD98% and heart ΔDmean. This study's results confirm that the RO approach was more robust than the MF in general. Although both techniques were able to generate clinically acceptable plans for breast radiotherapy, the RO could potentially improve workflow efficiency due to its simpler planning process.
Collapse
|
41
|
Keshtkar M, Mosleh-Shirazi MA, Saba V. Assessment of the effectiveness of Saba shielding with the composition of Cu-Bi in neck CT imaging: a phantom and patient study. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2023; 43:041503. [PMID: 37793369 DOI: 10.1088/1361-6498/acffd4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Accepted: 10/04/2023] [Indexed: 10/06/2023]
Abstract
The use of computed tomography (CT) is a very well-established medical diagnostic imaging modality, however, the high radiation dose due to this imaging method is a major concern. Therefore, dose reduction methods are necessary, especially for superficial radiosensitive organs like the thyroid. The aim of this study is to construct and assess a CT shield with composition of 90% Cu and 10% Bi (Saba shield) with regard to dose reduction and image quality. The efficiency of the constructed shields for dose reduction was assessed by measuring entrance skin dose (ESD), using thermoluminescence dosimeters placed on an anthropomorphic phantom. Image quality was assessed quantitatively based on image noise and CT number accuracy by drawing regions of interest on CT images of the anthropomorphic phantom. Image quality was further investigated qualitatively in a patient study. Application of the Saba shield and 100% Bi shield with the thickness of one thickness (1T) reduced ESD by 50.2% and 51.7%, respectively, and using a three-fold thickness reduced ESD by 64.6% and 65.1%, respectively. Saba shield with thickness of 1T had no significant change in image noise in the anterior part, and image noise and mean CT number in the posterior part (P> 0.05). The statistical analysis performed did not find any meaningful difference between the study and control groups in image quality assessment of the patient study (P> 0.05). The 1T Saba shield reduced thyroid dose efficiently during neck CT imaging without causing unwanted effects on image quality.
Collapse
|
42
|
Abstract
Dual-energy CT has expanded the potential of thoracic imaging in both children and adults. Data processing allows material- and energy-specific reconstructions, which improve material differentiation and tissue characterization compared with single-energy CT. Material-specific reconstructions include iodine, virtual unenhanced, perfusion blood volume, and lung vessel images, which can improve assessment of vascular, mediastinal, and parenchymal abnormalities. The energy-specific reconstruction algorithm allows virtual monoenergetic reconstructions, including low-energy images to increase iodine conspicuity and high-energy images to reduce beam-hardening and metal artifacts. This review highlights dual-energy CT principles, hardware, and postprocessing algorithms; the clinical applications of dual-energy CT; and the potential benefits of photon counting (the most recently introduced iteration of spectral imaging) in pediatric thoracic imaging.
Collapse
|
43
|
Styrvoky K, Schwalk A, Pham D, Madsen K, Chiu HT, Abu-Hijleh M. Radiation dose of cone beam CT combined with shape sensing robotic assisted bronchoscopy for the evaluation of pulmonary lesions: an observational single center study. J Thorac Dis 2023; 15:4836-4848. [PMID: 37868864 PMCID: PMC10586938 DOI: 10.21037/jtd-23-587] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2023] [Accepted: 08/18/2023] [Indexed: 10/24/2023]
Abstract
Background Shape sensing robotic-assisted bronchoscopy (ssRAB) combined with radial endobronchial ultrasound (r-EBUS) and cone beam computed tomography (CBCT) is a newer diagnostic modality for the evaluation of pulmonary lesions. There is limited data describing the radiation dose of CBCT combined with ssRAB. The purpose of this study was to describe the technical factors associated with the use of CBCT combined with ssRAB to biopsy pulmonary lesions. Methods We conducted a single center, prospective observational study of patients undergoing ssRAB combined with fixed CBCT for the pulmonary lesion biopsy. We report our patient demographics, and pulmonary lesion and procedure characteristics. Results A total of 241 ssRAB procedures were performed to biopsy 269 pulmonary lesions. The mean lesion size was measured in the following dimensions: anteroposterior (18.0±8.8 mm), transverse (17.2±10.5 mm), and craniocaudal (17.7±10.2 mm). A mean of 1.5±0.7 (median: 1, range: 1-4) CBCT spins were performed. The mean total fluoroscopy time (FT) was 5.6±2.9 minutes. The mean radiation dose of cumulative air kerma (CAK) was 63.5±46.7 mGy and the mean cumulative dose area product (DAP) was 22.6±16.0 Gy·cm2. Diagnostic yield calculated based on results at index bronchoscopy was 85.9%. There was a low rate of complications with 8 pneumothoraces (3.3%), 5 (2.1%) of which required chest tube placement. Conclusions We describe the use of ssRAB combined with CBCT to biopsy pulmonary lesions as a safe diagnostic modality with relatively low radiation dose that is potentially comparable to other image guided sampling modalities. Bronchoscopists should be cognizant of the radiation use during the procedure for both patient and staff safety.
Collapse
|
44
|
Aristizabal AM, Gutiérrez JA, Ramirez E, Mejía-Quiñones V, Ubeda C, Mosquera WF, Mosquera W. Diagnostic Reference Levels in Interventional Pediatric Cardiology: Two-Year Experience in a Tertiary Referral Hospital in Latin America. CHILDREN (BASEL, SWITZERLAND) 2023; 10:1588. [PMID: 37892251 PMCID: PMC10605529 DOI: 10.3390/children10101588] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2023] [Revised: 08/11/2023] [Accepted: 08/21/2023] [Indexed: 10/29/2023]
Abstract
The goal of the present study was to propose the first local diagnostic reference levels (DRLs) for interventional pediatric cardiology procedures in a large hospital in Colombia. The data collection period was from April 2020 to July 2022. The local DRLs were calculated as the 3rd quartile of patient-dose distributions for the kerma-area product (Pka) values. The sample of collected clinical procedures (255) was divided into diagnostic and therapeutic procedures and grouped into five weight and five age bands. The Pka differences found between diagnostic and therapeutic procedures were statistically significant in all weight and age bands, except for the 1-5-year age group. The local DRLs for weight bands were 3.82 Gy·cm2 (<5 kg), 7.39 Gy·cm2 (5-<15 kg), 19.72 Gy·cm2 (15-<30 kg), 28.99 Gy·cm2 (30-<50 kg), and 81.71 Gy·cm2 (50-<80 kg), respectively. For age bands, the DRLs were 3.97 Gy·cm2 (<1 y), 9.94 Gy·cm2 (1-<5 y), 20.82 Gy·cm2 (5-<10 y), 58.00 Gy·cm2 (10-<16 y), and 31.56 Gy·cm2 (<16 y), respectively. In conclusion, when comparing our results with other existing DRL values, we found that they are similar to other centers and thus there is scope to continue optimizing the radiation dose values. This will contribute to establishing national DRLs for Colombia in the near future.
Collapse
|
45
|
Ito M, Chida K, Onodera S, Kojima I, Iikubo M, Kato T, Fujisawa M, Zuguchi M. Evaluation of radiation dose and image quality for dental cone-beam computed tomography in pediatric patients. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2023; 43:031518. [PMID: 37696261 DOI: 10.1088/1361-6498/acf868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Accepted: 09/11/2023] [Indexed: 09/13/2023]
Abstract
Children are sensitive to radiation; therefore, it is necessary to reduce radiation dose as much as possible in pediatric patients. In addition, it is crucial to investigate the optimal imaging conditions as they considerably affect the radiation dose. In this study, we investigated the effect of different imaging conditions on image quality and optimized the imaging conditions for dental cone-beam computed tomography (CBCT) examinations to diagnose ectopic eruptions and impacted teeth in children. To achieve our aims, we evaluated radiation doses and subjective and objective image quality. The CBCT scans were performed using 3D Accuitomo F17. All combinations of a tube voltage (90 kV), tube currents (1, 2, 3 mA), fields of view (FOVs) (4 × 4, 6 × 6 cm), and rotation angles (360°, 180°) were used. Dose-area product values were measured. SedentexCT IQ cylindrical phantom was used to physically evaluate the image quality. We used the modulation transfer function as an index of resolution, the noise power spectrum as an index of noise characteristics, and the system performance function as an overall evaluation index of the image. Five dentists visually evaluated the images from the head-neck phantom. The results showed that the image quality tended to worsen, and scores for visual evaluation decreased as tube currents, FOVs and rotation angles decreased. In particular, image noise negatively affected the delineation of the periodontal ligament space. The optimal imaging conditions were 90 kV, 2 mA, 4 × 4 cm FOV and 180° rotation. These results suggest that CBCT radiation doses can be significantly reduced by optimizing the imaging conditions.
Collapse
|
46
|
Siegel MJ, Bugenhagen SM, Sanchez A, Kim S, Abadia A, Ramirez-Giraldo JC. Comparison of Radiation Dose and Image Quality of Pediatric High-Resolution Chest CT Between Photon-Counting Detector CT and Energy-Integrated Detector CT: A Matched Study. AJR Am J Roentgenol 2023; 221:363-371. [PMID: 37095666 DOI: 10.2214/ajr.23.29077] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/08/2023]
Abstract
BACKGROUND. Photon-counting detector (PCD) CT has been shown to reduce radiation dose and improve image quality in adult chest CT examinations; its potential impact in pediatric CT is not well documented. OBJECTIVE. The purpose of our study was to compare radiation dose, objective image quality, and subjective image quality of PCD CT and energy-integrating detector (EID) CT in children undergoing high-resolution CT (HRCT) of the chest. METHODS. This retrospective study included 27 children (median age, 3.9 years; 10 girls, 17 boys) who underwent PCD CT between March 1, 2022, and August 31, 2022, and 27 children (median age, 4.0 years; 13 girls, 14 boys) who underwent EID CT between August 1, 2021, and January 31, 2022; all examinations comprised clinically indicated chest HRCT. The patients in the two groups were matched by age and water-equivalent diameter. Radiation dose parameters were recorded. One observer placed ROIs to measure objective parameters (lung attenuation, image noise, and SNR). Two radiologists independently assessed subjective measures (overall image quality and motion artifacts) using 5-point Likert scales (1 = highest quality). Groups were compared. RESULTS. PCD CT, in comparison with EID CT, showed lower median CTDIvol (0.41 vs 0.71 mGy, p < .001), DLP (10.2 vs 13.7 mGy × cm, p = .008), size-specific dose estimate (0.82 vs 1.34 mGy, p < .001), and tube current-exposure time product (48.0 vs 202.0 mAs, p < .001). PCD CT and EID CT showed no significant difference in right upper lobe (RUL) lung attenuation (mean, -793 vs -750 HU; p = .09), right lower lobe (RLL) lung attenuation (mean, -745 vs -716 HU; p = .23), RUL image noise (mean, 55 vs 51 HU; p = .27), RLL image noise (mean, 59 vs 57 HU; p = .48), RUL SNR (mean, -14.9 vs -15.8; p = .89), or RLL SNR (mean, -13.1 vs -13.6; p = .79). PCD CT and EID CT showed no significant difference in median overall image quality for reader 1 (1.0 vs 1.0, p = .28) or reader 2 (1.0 vs 1.0, p = .17) or median motion artifacts for reader 1 (1.0 vs 1.0, p = .07) or reader 2 (1.0 vs 1.0, p = .22). CONCLUSION. PCD CT showed significantly reduced dose levels without a significant difference in objective or subjective image quality compared with EID CT. CLINICAL IMPACT. These data expand understanding of the capabilities of PCD CT and support its routine use in children.
Collapse
|
47
|
Kawauchi S, Chida K, Hamada Y, Tsuruta W. Image Quality and Radiation Dose of Conventional and Wide-Field High-Resolution Cone-Beam Computed Tomography for Cerebral Angiography: A Phantom Study. Tomography 2023; 9:1683-1693. [PMID: 37736987 PMCID: PMC10514806 DOI: 10.3390/tomography9050134] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Revised: 08/24/2023] [Accepted: 08/29/2023] [Indexed: 09/23/2023] Open
Abstract
There has been an increase in the use of interventional neuroradiology procedures because of their non-invasiveness compared to surgeries and the improved image quality of fluoroscopy, digital subtraction angiography, and rotational angiography. Although cone-beam computed tomography (CBCT) images are inferior to multi-detector CT images in terms of low-contrast detectability and lower radiation doses, CBCT scans are frequently performed because of their accessibility. This study aimed to evaluate the image quality and radiation dose of two different high-resolution CBCTs (HR CBCT): conventional (C-HR CBCT) and wide-field HR CBCT (W-HR CBCT). The modulation transfer function (MTF), noise power spectrum (NPS), and contrast-to-noise ratio (CNR) were used to evaluate the image quality. On comparing the MTF of C-HR CBCT with a 256 × 256 matrix and that of W-HR CBCT with a 384 × 384 matrix, the MTF of W-HR CBCT with the 384 × 384 matrix was larger. A comparison of the NPS and CNR of C-HR CBCT with a 256 × 256 matrix and W-HR CBCT with a 384 × 384 matrix showed that both values were comparable. The reference air kerma values were equal for C-HR CBCT and W-HR CBCT; however, the value of the kerma area product was 1.44 times higher for W-HR CBCT compared to C-HR CBCT. The W-HR CBCT allowed for improved spatial resolution while maintaining the image noise and low-contrast detectability by changing the number of image matrices from 256 × 256 to 384 × 384. Our study revealed the image characteristics and radiation dose of W-HR CBCT. Given its advantages of low-contrast detectability and wide-area imaging with high spatial resolution, W-HR CBCT may be useful in interventional neuroradiology for acute ischemic stroke.
Collapse
|
48
|
Ludes G, Ohana M, Labani A, Meyer N, Moliére S, Roy C. Impact of a reduced iodine load with deep learning reconstruction on abdominal MDCT. Medicine (Baltimore) 2023; 102:e34579. [PMID: 37657067 PMCID: PMC10476859 DOI: 10.1097/md.0000000000034579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Accepted: 07/13/2023] [Indexed: 09/03/2023] Open
Abstract
To evaluate the impact of a reduced iodine load using deep learning reconstruction (DLR) on the hepatic parenchyma compared to conventional iterative reconstruction (hybrid IR) and its consequence on the radiation dose and image quality. This retrospective monocentric intraindividual comparison study included 66 patients explored at the portal phase using different multidetector computed tomography parameters: Group A, hybrid IR algorithm (hybrid IR) and a nonionic low-osmolality contrast agent (350 mgI/mL); Group B, DLR algorithm (DLR) and a nonionic iso-osmolality contrast agent (270 mgI/mL). We recorded the attenuation of the liver parenchyma, image quality, and radiation dose parameters. The mean hounsfield units (HU) value of the liver parenchyma was significantly lower in group B, at 105.9 ± 10.9 HU versus 118.5 ± 14.6 HU in group A. However, the 90%IC of mean liver attenuation in the group B (DLR) was between 100.8 HU and 109.3 HU. The signal-to-noise ratio of the liver parenchyma was significantly higher on DLR images, increasing by 56%. However, for both the contrast-to-noise ratio (CNR) and CNR liver/PV no statistical difference was found, even if the CNR liver/PV ratio was slightly higher for group A. The mean dose-length product and computed tomography dose index volume values were significantly lower with DLR, corresponding to a radiation dose reduction of 36% for the DLR. Using a DLR algorithm for abdominal multidetector computed tomography with a low iodine load can provide sufficient enhancement of the liver parenchyma up to 100 HU in addition to the advantages of a higher image quality, a better signal-to-noise ratio and a lower radiation dose.
Collapse
|
49
|
Kawashima H, Ichikawa K, Kitao A, Matsubara T, Sugiura T, Kobayashi T, Kobayashi S. Radiation dose considerations in digital radiography with an anti-scatter grid: A study using adult and pediatric phantoms. J Appl Clin Med Phys 2023; 24:e14081. [PMID: 37491809 PMCID: PMC10476983 DOI: 10.1002/acm2.14081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2022] [Revised: 05/23/2023] [Accepted: 06/08/2023] [Indexed: 07/27/2023] Open
Abstract
BACKGROUND When using an anti-scatter grid, a decrease in receptor dose caused by its X-ray absorption seems to lead to the misperception that radiation dose needs to be increased even in digital radiography (DR). OBJECTIVE To demonstrate that there is no need to increase radiation dose in DR with a grid, based on a visual evaluation using an adult and a pediatric abdomen phantom (PAD and PPD , respectively). MATERIALS AND METHODS Phantom images with and without a grid were obtained with exposure parameters determined based on a preliminarily measured signal-to-noise ratio improvement factor (SIF), an index for potential dose reduction when using a grid. In visual evaluation, four radiologists compared phantom images with a grid applied at different dose reduction rates (0% [no reduction], 18%, 36%, and 59% for PAD and 0% and 11% for PPD ) against an image without a grid at the baseline dose (as the reference). They graded the overall image quality of the former relative to that of the latter (reference) on a 3-point scale (3 = better, 2 = almost equal, 1 = worse). RESULTS The mean scores for dose reduction rates of 0%, 18%, 36%, and 59% were 3.00, 3.00, 2.75, and 1.00, respectively, for PAD ; those for 0% and 11% were 2.13 and 1.63, respectively, for PPD . These results support the validity of our view that no dose increase is necessary when using an anti-scatter grid. Actually, there is even a potential for improvement in image quality with dose reduction rates of ≤36% for PAD . CONCLUSION It is worth reconsidering the necessity of increasing radiation dose in the DR imaging of the adult and pediatric abdomens with an anti-scatter grid.
Collapse
|
50
|
Stahl R, D’Anastasi M, Forbrig R, Liebig T, Katzendobler S, Weller J, Trumm CG. Accuracy, Hemorrhagic Complications and CT Radiation Dose of Emergency External Ventricular Drain (EVD) Placement in Pediatric Patients: A 15-Year Retrospective Analysis. Diagnostics (Basel) 2023; 13:2805. [PMID: 37685340 PMCID: PMC10486425 DOI: 10.3390/diagnostics13172805] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2023] [Revised: 08/25/2023] [Accepted: 08/28/2023] [Indexed: 09/10/2023] Open
Abstract
PURPOSE To assess accuracy, the frequency of hemorrhagic complications and computed tomography (CT) radiation dose parameters in pediatric patients undergoing landmark-guided external ventricular drain (EVD) placement in an emergency setting. METHODS Retrospective analysis comprised 36 EVD placements with subsequent CT control scans in 29 patients (aged 0 to 17 years) in our university hospital from 2008 to 2022. The position of the EVD as well as the presence and extension of bleeding were classified according to previously established grading schemes. Dose length product (DLP), volume-weighted CT dose index (CTDIvol) and scan length were extracted from the radiation dose reports and compared to the diagnostic reference values (DRLs) issued by the German Federal Office for Radiation Protection. RESULTS After the initial EVD placement, optimal positioning of the catheter tip into the ipsilateral frontal horn or third ventricle (Grade I), or a functional positioning in the contralateral lateral ventricle or the non-eloquent cortex (Grade II), was achieved in 28 and 8 cases, respectively. In 32 of 36 procedures, no evidence of hemorrhage was present in the control CT scan. Grade 1 (<1 mL) and Grade 2 (≥1 to 15 mL) bleedings were detected after 3 and 1 placement(s), respectively. For control scans after EVD placements, CTDIvol (median [25%; 75% quartile]) was 39.92 [30.80; 45.55] mGy, DLP yielded 475.50 [375.00; 624.75] mGy*cm and the scan length result was 136 [120; 166] mm. Exceedances of the DRL values were observed in 14.5% for CTDIvol, 12.7% for DLP and 65.6% for the scan length. None of these values was in the range requiring a report to the national authorities. CONCLUSION Landmark-based emergency EVD placement in pediatric patients yielded an optimal position in most cases already after the initial insertion. Complications in terms of secondary hemorrhages are rare. CT dose levels associated with the intervention are below the reportable threshold of the national DRLs in Germany.
Collapse
|