76
|
Prieto A, Bellas F, Trueba P, Duro R. Towards the standardization of distributed Embodied Evolution. Inf Sci (N Y) 2015. [DOI: 10.1016/j.ins.2015.03.044] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
77
|
Cavalheiro J, Prieto A, Zuloaga O, Preudhomme H, Amouroux D, Monperrus M. Evaluation of preconcentration methods in the analysis of synthetic musks in whole-water samples. J Sep Sci 2015; 38:2298-304. [PMID: 25885885 DOI: 10.1002/jssc.201500192] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2015] [Revised: 04/01/2015] [Accepted: 04/02/2015] [Indexed: 11/12/2022]
Abstract
According to the European Water Framework Directive, environmental assessment of organic compounds should be made in whole-water samples, but due to their hydrophobicity and strong attraction to organic content these compounds can be found bound to suspended particle matter or in the dissolved fraction. In this work, the extraction of musk compounds was studied in whole-water samples exhibiting different amounts of dissolved organic carbon and suspended particulate matter using polyethersulfone preconcentration technique. Matrix effects in estuarine and wastewater (both influent and effluent) were evaluated for filtered and unfiltered samples. For unfiltered samples, estuarine water exhibited matrix effects <20%, while for effluent it was up to 48% and for influent ranged from 85 to 99%. To compensate matrix effects and determine total concentrations in unfiltered samples, different quantification approaches were tested: the use of deuterated analogues and standard additions. Standard additions provided the best results for unfiltered samples. Finally, filtered and unfiltered samples were analyzed using both polyethersulfone preconcentration and membrane-assisted solvent extraction and results showed a good agreement between the two methods. In both cases unfiltered samples provided concentrations 1.5-2.6 times higher than filtered samples.
Collapse
|
78
|
Bizkarguenaga E, Zabaleta I, Iparraguirre A, Aguirre J, Fernández LÁ, Berger U, Prieto A, Zuloaga O. Enrichment of perfluorinated alkyl substances on polyethersulfone using 1-methylpyperidine as ion-pair reagent for the clean-up of carrot and amended soil extracts. Talanta 2015; 143:263-270. [PMID: 26078158 DOI: 10.1016/j.talanta.2015.04.062] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2015] [Revised: 04/17/2015] [Accepted: 04/21/2015] [Indexed: 11/24/2022]
Abstract
The development of a simple, cheap and environment friendly analytical method for the simultaneous determination of different perfluoroalkyl substances (PFASs) including seven perfluoroalkyl carboxylic acids, three perfluoroalkane sulfonic acids and perfluorooctanesulfonamide in carrot and amended soil was carried out in the present work. The method was based on focused ultrasound solid-liquid extraction followed by extract clean-up through enrichment of the target compounds on a polymeric material using an ion-pair reagent and detection by liquid chromatography-tandem mass spectrometry. The following variables affecting the clean-up step were evaluated: the nature of the polymeric material (polyethersulfone, PES, versus silicone rod), the amount of the polymeric material (from 1 to 9 mg), the ion-pair reagent (1-methylpyperidine, 1-MP, versus tetrabutylammonium salts), the concentration of the ion-pair reagent (from 5 to 50 mM) and the extraction time (from 15 min to 24 h). Optimum clean-up conditions were obtained using preconcentration on 9 mg of PES polymeric material combined with 5 mM 1-MP as ion-pair reagent for 3h. The method was validated in terms of apparent recoveries in the range of 77-140% and 95-137% at the low concentration (50 ng g(-1)) and in the range of 70-136% and 79-132% at the high concentration (290 ng g(-1)) for amended soil and carrot, respectively, after correction with the corresponding labeled standards. Precision, as relative standard deviation, was within 2-23%, while method detection limits were 0.31-2.85 ng g(-1) for amended soil and 0.11-1.83 ng g(-1) for carrot. In the absence of a certified reference material for the target analytes in the matrices studied, inter-method comparison was carried out and the same samples were processed using two independent clean-up procedures, the one developed in the present work and a classical based on solid-phase extraction. Statistically comparable results were obtained according to the one-way analysis of variance for peel, core, leaves as well as amended soil (F(Calc)=2.59, 5.06, 5.82 and 2.34 <F(Crit)=7.71). Finally, the method was applied for the determination of PFASs in uptake experiments where carrots were cultivated in an amended soil polluted with perfluorooctane sulfonic acid (PFOS) at 500 ng g(-1) level. The highest concentration was measured in the carrot leaves (669 ng g(-1)), while the concentrations in peel and core were at the same level (72 ng g(-1) and 62 ng g(-1) respectively), concluding that translocation of PFOS from the soil to the leaves had occurred.
Collapse
|
79
|
Mijangos L, Bizkarguenaga E, Prieto A, Fernández LA, Zuloaga O. Simultaneous determination of a variety of endocrine disrupting compounds in carrot, lettuce and amended soil by means of focused ultrasonic solid-liquid extraction and dispersive solid-phase extraction as simplified clean-up strategy. J Chromatogr A 2015; 1389:8-18. [PMID: 25746759 DOI: 10.1016/j.chroma.2015.02.036] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2014] [Revised: 01/21/2015] [Accepted: 02/11/2015] [Indexed: 11/30/2022]
Abstract
The present study is focused on the development of an analytical method based on focused ultrasonic solid-liquid extraction (FUSLE) followed by dispersive solid-phase extraction (dSPE) clean-up and liquid chromatography-triple quadrupole tandem mass spectrometry (LC-MS/MS) optimised for the simultaneous analysis of certain endocrine disrupting compounds (EDCs), including alkylphenols (APs), bisphenol A (BPA), triclosan (TCS) and several hormones and sterols in vegetables (lettuce and carrot) and amended soil samples. Different variables affecting the chromatographic separation, the electrospray ionisation and mass spectrometric detection were optimised in order to improve the sensitivity of the separation and detection steps. Under the optimised extraction conditions (sonication of 5min at 33% of power with pulse times on of 0.8s and pulse times off of 0.2s in 10mL of n-hexane:acetone (30:70, v:v) mixture using an ice bath), different dSPE clean-up sorbents, such as Florisil, Envi-Carb, primary-secondary amine bonded silica (PSA) and C18, or combinations of them were evaluated for FUSLE extracts before LC-MS/MS. Apparent recoveries and precision in terms of relative standard deviation (RSDs %) of the method were determined at two different fortification levels (according to the matrix and the analyte) and values in the 70-130% and 2-27% ranges, respectively, were obtained for most of the target analytes and matrices. Matrix-matched calibration approach and the use of labelled standards as surrogates were needed for the properly quantification of most analytes and matrices. Method detection limits (MDLs), estimated with fortified samples, in the ranges of 0.1-100ng/g for carrot, 0.2-152ng/g for lettuce and 0.9-31ng/g for amended soil were obtained. The developed methodology was applied to the analysis of 11 EDCs in both real vegetable bought in a local market and in compost (from a local wastewater treatment plant, WWTP) amended soil samples.
Collapse
|
80
|
Brienen RJW, Phillips OL, Feldpausch TR, Gloor E, Baker TR, Lloyd J, Lopez-Gonzalez G, Monteagudo-Mendoza A, Malhi Y, Lewis SL, Vásquez Martinez R, Alexiades M, Álvarez Dávila E, Alvarez-Loayza P, Andrade A, Aragão LEOC, Araujo-Murakami A, Arets EJMM, Arroyo L, Aymard C GA, Bánki OS, Baraloto C, Barroso J, Bonal D, Boot RGA, Camargo JLC, Castilho CV, Chama V, Chao KJ, Chave J, Comiskey JA, Cornejo Valverde F, da Costa L, de Oliveira EA, Di Fiore A, Erwin TL, Fauset S, Forsthofer M, Galbraith DR, Grahame ES, Groot N, Hérault B, Higuchi N, Honorio Coronado EN, Keeling H, Killeen TJ, Laurance WF, Laurance S, Licona J, Magnussen WE, Marimon BS, Marimon-Junior BH, Mendoza C, Neill DA, Nogueira EM, Núñez P, Pallqui Camacho NC, Parada A, Pardo-Molina G, Peacock J, Peña-Claros M, Pickavance GC, Pitman NCA, Poorter L, Prieto A, Quesada CA, Ramírez F, Ramírez-Angulo H, Restrepo Z, Roopsind A, Rudas A, Salomão RP, Schwarz M, Silva N, Silva-Espejo JE, Silveira M, Stropp J, Talbot J, ter Steege H, Teran-Aguilar J, Terborgh J, Thomas-Caesar R, Toledo M, Torello-Raventos M, Umetsu RK, van der Heijden GMF, van der Hout P, Guimarães Vieira IC, Vieira SA, Vilanova E, Vos VA, Zagt RJ. Long-term decline of the Amazon carbon sink. Nature 2015; 519:344-8. [PMID: 25788097 DOI: 10.1038/nature14283] [Citation(s) in RCA: 339] [Impact Index Per Article: 37.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2014] [Accepted: 02/04/2015] [Indexed: 11/09/2022]
Abstract
Atmospheric carbon dioxide records indicate that the land surface has acted as a strong global carbon sink over recent decades, with a substantial fraction of this sink probably located in the tropics, particularly in the Amazon. Nevertheless, it is unclear how the terrestrial carbon sink will evolve as climate and atmospheric composition continue to change. Here we analyse the historical evolution of the biomass dynamics of the Amazon rainforest over three decades using a distributed network of 321 plots. While this analysis confirms that Amazon forests have acted as a long-term net biomass sink, we find a long-term decreasing trend of carbon accumulation. Rates of net increase in above-ground biomass declined by one-third during the past decade compared to the 1990s. This is a consequence of growth rate increases levelling off recently, while biomass mortality persistently increased throughout, leading to a shortening of carbon residence times. Potential drivers for the mortality increase include greater climate variability, and feedbacks of faster growth on mortality, resulting in shortened tree longevity. The observed decline of the Amazon sink diverges markedly from the recent increase in terrestrial carbon uptake at the global scale, and is contrary to expectations based on models.
Collapse
|
81
|
Zabaleta I, Bizkarguenaga E, Prieto A, Ortiz-Zarragoitia M, Fernández L, Zuloaga O. Simultaneous determination of perfluorinated compounds and their potential precursors in mussel tissue and fish muscle tissue and liver samples by liquid chromatography–electrospray-tandem mass spectrometry. J Chromatogr A 2015; 1387:13-23. [DOI: 10.1016/j.chroma.2015.01.089] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2014] [Revised: 01/29/2015] [Accepted: 01/29/2015] [Indexed: 02/01/2023]
|
82
|
Ros O, Vallejo A, Blanco-Zubiaguirre L, Olivares M, Delgado A, Etxebarria N, Prieto A. Microextraction with polyethersulfone for bisphenol-A, alkylphenols and hormones determination in water samples by means of gas chromatography–mass spectrometry and liquid chromatography–tandem mass spectrometry analysis. Talanta 2015; 134:247-255. [DOI: 10.1016/j.talanta.2014.11.015] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2014] [Revised: 11/05/2014] [Accepted: 11/08/2014] [Indexed: 10/24/2022]
|
83
|
González-Ortegón E, Walton MEM, Moghaddam B, Vilas C, Prieto A, Kennedy HA, Pedro Cañavate J, Le Vay L. Flow regime in a restored wetland determines trophic links and species composition in the aquatic macroinvertebrate community. THE SCIENCE OF THE TOTAL ENVIRONMENT 2015; 503-504:241-250. [PMID: 25242150 DOI: 10.1016/j.scitotenv.2014.09.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/15/2014] [Revised: 09/01/2014] [Accepted: 09/01/2014] [Indexed: 06/03/2023]
Abstract
In a restored wetland (South of Spain), where different flow regimes control water exchange with the adjacent Guadalquivir estuary, the native Palaemon varians coexists with an exotic counterpart species Palaemon macrodactylus. This controlled m\acrocosm offers an excellent opportunity to investigate how the effects of water management, through different flow regimes, and the presence of a non-native species affect the aquatic community and the trophic niche (by gut contents and C-N isotopic composition) of the native shrimp Palaemon varians. We found that increased water exchange rate (5% day(-1) in mixed ponds vs. 0.1% day(-1) in extensive ponds) modified the aquatic community of this wetland; while extensive ponds are dominated by isopods and amphipods with low presence of P. macrodactylus, mixed ponds presented high biomass of mysids, corixids, copepods and both shrimp species. An estuarine origin of nutrients and primary production might explain seasonal and spatial differences found among ponds of this wetland. A combined analysis of gut contents and isotopic composition of the native and the exotic species showed that: (1) native P. varians is mainly omnivorous (2) while the non-native P. macrodactylus is more zooplanktivorous and (3) a dietary overlap occurred when both species coexist at mixed ponds where a higher water exchange and high abundance of mysids and copepods diversifies the native species' diet. Thus differences in the trophic ecology of both species are clearly explained by water management. This experimental study is a valuable tool for integrated management between river basin and wetlands since it allows quantification of wetland community changes in response to the flow regime.
Collapse
|
84
|
Blanco-Zubiaguirre L, Delgado A, Ros O, Posada-Ureta O, Vallejo A, Prieto A, Olivares M, Etxebarria N. Assessment of commercially available polymeric materials for sorptive microextraction of priority and emerging nonpolar organic pollutants in environmental water samples. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2014; 21:11867-11883. [PMID: 24424482 DOI: 10.1007/s11356-013-2481-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2013] [Accepted: 12/18/2013] [Indexed: 06/03/2023]
Abstract
Among the different organic pollutants, persistent organic pollutants and emerging organic contaminants (EOCs) are of particular concern due to their potentially dangerous effects on the ecosystems and on human health. In the framework of the analysis of some of these organic pollutants in water samples, sorptive extraction devices have proven to be adequate for their monitoring. The efficiency of four commercially available and low-cost polymeric materials [polypropylene, poly(ethylene terephthalate), Raffia, and polyethersulfone (PES)] for the simultaneous extraction of 16 organic compounds from five different families from environmental water samples was evaluated in this work. Firstly, the homogeneity of the sorbent materials was confirmed by means of Raman spectroscopy. After the optimization of the parameters affecting the extraction and the liquid desorption steps, it was found that PES showed the largest efficiencies for slightly polar analytes and, to a lesser extent, for nonpolar analytes. Additionally, Raffia rendered good extraction efficiencies for nonpolar compounds. Thus sorptive extraction methods followed by large volume injection-programmable temperature vaporizer-gas chromatography-mass spectrometry were validated using PES and Raffia as sorbent materials. The validation of the method provided good linearity (0.978 < r (2) < 0.999 for PES and 0.977 < r (2) < 0.999 for Raffia), adequate repeatability (below 19 % and 14 % for PES and Raffia, respectively), and low method detection limits (low ng · l(-1) level). Finally, these materials were applied to the analysis of contaminants in environmental water samples.
Collapse
|
85
|
Iparraguirre A, Rodil R, Quintana JB, Bizkarguenaga E, Prieto A, Zuloaga O, Cela R, Fernández LA. Matrix solid-phase dispersion of polybrominated diphenyl ethers and their hydroxylated and methoxylated analogues in lettuce, carrot and soil. J Chromatogr A 2014; 1360:57-65. [PMID: 25130091 DOI: 10.1016/j.chroma.2014.07.079] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2014] [Revised: 07/22/2014] [Accepted: 07/24/2014] [Indexed: 11/26/2022]
Abstract
In the present work, a novel analytical method for the simultaneous determination of ten polybrominated diphenyl ethers (PBDEs), eight methoxylated PBDEs (MeO-PBDEs) and seven hydroxylated PBDEs (OH-PBDEs) in soil, lettuce and carrot samples was developed. The procedure was based on matrix solid-phase dispersion (MSPD) followed by gas chromatography coupled to negative chemical ionization-mass spectrometry (GC-NCI-MS). Under optimum conditions, 0.5g of sample (freeze-dried in the case of lettuce and carrot samples) was dispersed with 0.5g of octadecyl-functionalized silica (C18) and 1.75g of acidified silica (10% H2SO4, w/w) was used as clean-up sorbent. A two-step fractionated elution was carried out. First, PBDEs and MeO-PBDEs were eluted in 75:25% (v/v) n-hexane/dichloromethane mixture and, then, the retained OH-PBDEs were eluted in pure dichloromethane. Both extracts were analyzed by GC-NCI-MS separately, in the case of OH-PBDEs after derivatization with N-methyl-N-(trimethylsilyl) trifluoroacetamide. The developed method was validated in terms of accuracy for soil, lettuce and carrot matrices, spiked at two fortification levels (5 and 25ngg(-1)). After correction with the corresponding surrogate, apparent recovery values (defined as the recovery obtained after correction with the corresponding surrogate) were in the 80-129% range. Precision (as relative standard deviation) in the 1-21% range and method detection limits (MDLs) in the 0.003 and 0.3ngg(-1) range for soil and in the 0.003-0.4ngg(-1) range (dry weight) for lettuce and carrot samples were obtained. For PBDEs the method was also validated with a standard reference material (SRM-2585) of house dust. Finally, the method was applied for the determination of target analytes in soil, lettuce and carrot.
Collapse
|
86
|
Macías A, de la Cruz A, Prieto A, Peraza DA, Tamkun MM, González T, Valenzuela C. PKC inhibition results in a Kv 1.5 + Kv β1.3 pharmacology closer to Kv 1.5 channels. Br J Pharmacol 2014; 171:4914-26. [PMID: 24946104 DOI: 10.1111/bph.12822] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2013] [Revised: 05/27/2014] [Accepted: 06/05/2014] [Indexed: 01/04/2023] Open
Abstract
BACKGROUND AND PURPOSE The Kv β1.3 subunit modifies the gating and pharmacology of Kv 1.5 channels in a PKC-dependent manner, decreasing channel sensitivity to bupivacaine- and quinidine-mediated blockade. Cardiac Kv 1.5 channels associate with receptor for activated C kinase 1 (RACK1), the Kv β1.3 subunit and different PKC isoforms, resulting in the formation of a functional channelosome. The aim of the present study was to investigate the effects of PKC inhibition on bupivacaine and quinidine block of Kv 1.5 + Kv β1.3 channels. EXPERIMENTAL APPROACH HEK293 cells were transfected with Kv 1.5 + Kv β1.3 channels, and currents were recorded using the whole-cell configuration of the patch-clamp technique. PKC inhibition was achieved by incubating the cells with either calphostin C or bisindolylmaleimide II and the effects of bupivacaine and quinidine were analysed. KEY RESULTS The voltage-dependent inactivation of Kv 1.5 + Kv β1.3 channels and their pharmacological behaviour after PKC inhibition with calphostin C were similar to those displayed by Kv 1.5 channels alone. Indeed, the IC50 values for bupivacaine were similar in cells whose PKC was inhibited with calphostin C or bisindolylmaleimide II. Similar results were also observed in the presence of quinidine. CONCLUSIONS AND IMPLICATIONS The finding that the voltage-dependence of inactivation and the pharmacology of Kv 1.5 + Kv β1.3 channels after PKC inhibition resembled that observed in Kv 1.5 channels suggests that both processes are dependent on PKC-mediated phosphorylation. These results may have clinical relevance in diseases that are characterized by alterations in kinase activity.
Collapse
|
87
|
Arcos A, Romero L, Gelabert M, Prieto A, Pardo J, Osorio XR, Arráez MA. Can we predict the response in the treatment of epilepsy with vagus nerve stimulation? Neurosurg Rev 2014; 37:661-8. [PMID: 24838990 DOI: 10.1007/s10143-014-0555-5] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2012] [Revised: 02/25/2014] [Accepted: 04/13/2014] [Indexed: 11/29/2022]
Abstract
Despite the introduction of new antiepileptic drugs and advances in the surgical treatment of epilepsy, an important group of patients still remains uncontrolled by any of these methods. The relatively recent introduction of vagus nerve stimulation is yet another possible treatment for refractory epilepsy. This safe, simple, and adjustable technique reduces the number of seizures and multiple publications support its increasing efficacy and effectiveness, with few adverse effects. The goal of our study is to determine the efficacy of this procedure and the factors predicting a response, particularly in the presence of a temporal lobe discharge on the video electroencephalogram (video-EEG) and magnetic resonance imaging (MRI) lesions. We undertook a retrospective study of all the patients with refractory epilepsy who underwent implantation of a vagus nerve stimulator between 2003 and 2009, and with a minimum follow-up of 6 months. The statistical analysis was done with SPSS for Windows. The stimulator was implanted in 40 patients, of whom 38 had a minimum follow-up of 6 months. In one patient, the device had to be removed due to infection, so the series comprised 37 patients. These were divided into different groups, according to the epidemiologic, clinical, radiologic, and electroencephalographic data. In addition, an analysis of the response was performed. The efficacy of the procedure was established according to the reduction in the mean seizure frequency. The baseline value of these seizures was 80.97 ± 143.59, falling to 37 ± 82.51 at the last revision. The response rate (reduction in seizures ≥ 50 %) at 6 months was 51.4 %, with 62.2 % of the patients showing this reduction at the last evaluation. Significant differences in the response were seen for the variables: baseline frequency of seizures, temporal lobe discharge on VideoEEG and MRI lesions. The mean time to response was 10 months in patients with lower rate of seizures versus 25 months of those with the higher rate (p = 0.024), and the response at 6 months was higher (p = 0.05). Patients with temporal lobe discharge alone or in combination with discharges over other regions had a mean time to response of 11 months versus 26 months in those without temporal discharge (p = 0.037). In the analysis of the MRI, we had seen that at the last revision, 82.4 % of the patients with lesion had achieved response versus 45 % without lesion (p = 0.02). Vagus nerve stimulation reduces the frequency of seizures. A temporal lobe discharge on the video-EEG is an indicator of an early response and the presence of an MRI lesion indicates a late response. Patients with fewer rates of seizures have a better prognosis.
Collapse
|
88
|
Bizarro C, Ros O, Vallejo A, Prieto A, Etxebarria N, Cajaraville MP, Ortiz-Zarragoitia M. Intersex condition and molecular markers of endocrine disruption in relation with burdens of emerging pollutants in thicklip grey mullets (Chelon labrosus) from Basque estuaries (South-East Bay of Biscay). MARINE ENVIRONMENTAL RESEARCH 2014; 96:19-28. [PMID: 24262030 DOI: 10.1016/j.marenvres.2013.10.009] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2013] [Revised: 10/17/2013] [Accepted: 10/25/2013] [Indexed: 06/02/2023]
Abstract
Endocrine disrupting chemicals (EDCs) interfere with the functioning of the endocrine system, causing reproductive and developmental disturbances in aquatic wildlife. Appearance of intersex gonads and elevated plasma levels of vitellogenin in male fish are well known biomarkers of exposure to xenoestrogenic EDCs. In the present study, intersex condition and transcription levels of vtg and cyp19a1b were assessed in five thicklip grey mullet populations from the Basque coast (Bay of Biscay). Levels of EDCs (estrogenic hormones, polycyclic musks, bisphenol-A, phthalates, alkylphenols and pesticides) were determined in water and fish bile. Intersex gonads were observed in three out of five mullet populations. Vtg and cyp19a1b were up-regulated in mullet populations with relatively higher EDCs load. Phthalates and pesticides were the most abundant EDCs in bile, followed by alkylphenols, musks, bisphenol-A and estrogenic hormones. Statistically significant correlations were found between concentrations of individual and total EDCs in bile and water samples and transcription levels of vtg and cyp19a1b.
Collapse
|
89
|
Cavalheiro J, Monperrus M, Amouroux D, Preud’Homme H, Prieto A, Zuloaga O. In-port derivatization coupled to different extraction techniques for the determination of alkylphenols in environmental water samples. J Chromatogr A 2014; 1340:1-7. [DOI: 10.1016/j.chroma.2014.03.013] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2013] [Revised: 03/02/2014] [Accepted: 03/04/2014] [Indexed: 11/15/2022]
|
90
|
Bizkarguenaga E, Iparragirre A, Zabaleta I, Vallejo A, Fernández LA, Prieto A, Zuloaga O. Focused ultrasound assisted extraction for the determination of PBDEs in vegetables and amended soil. Talanta 2014; 119:53-9. [DOI: 10.1016/j.talanta.2013.10.021] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2013] [Revised: 10/04/2013] [Accepted: 10/15/2013] [Indexed: 11/26/2022]
|
91
|
Prieto A, Rodil R, Quintana JB, Cela R, Möder M, Rodríguez I. Evaluation of polyethersulfone performance for the microextraction of polar chlorinated herbicides from environmental water samples. Talanta 2014; 122:264-71. [PMID: 24720994 DOI: 10.1016/j.talanta.2014.01.024] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2013] [Revised: 01/15/2014] [Accepted: 01/20/2014] [Indexed: 10/25/2022]
Abstract
In this work, the suitability of bulk polyethersulfone (PES) for sorptive microextraction of eight polar, chlorinated phenoxy acids and dicamba from environmental water samples is assessed and the analytical features of the optimized method are compared to those reported for other microextraction techniques. Under optimized conditions, extractions were performed with samples (18 mL) adjusted at pH 2 and containing a 30% (w/v) of sodium chloride, using a tubular PES sorbent (1 cm length × 0.7 mm o.d., sorbent volume 8 µL). Equilibrium conditions were achieved after 3h of direct sampling, with absolute extraction efficiencies ranging from 39 to 66%, depending on the compound. Analytes were recovered soaking the polymer with 0.1 mL of ethyl acetate, derivatized and determined by gas chromatography-mass spectrometry (GC-MS). Achieved quantification limits (LOQs) varied between 0.005 and 0.073 ng mL(-1). After normalization with the internal surrogate (IS), the efficiency of the extraction was only moderately affected by the particular characteristics of different water samples (surface and sewage water); thus, pseudo-external calibration, using spiked ultrapure water solutions, can be used as quantification technique. The reduced cost of the PES polymer allowed considering it as a disposable sorbent, avoiding variations in the performance of the extraction due to cross-contamination problems and/or surface modification with usage.
Collapse
|
92
|
Aguirre J, Bizkarguenaga E, Iparraguirre A, Fernández LÁ, Zuloaga O, Prieto A. Development of stir-bar sorptive extraction-thermal desorption-gas chromatography-mass spectrometry for the analysis of musks in vegetables and amended soils. Anal Chim Acta 2014; 812:74-82. [PMID: 24491767 DOI: 10.1016/j.aca.2013.12.036] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2013] [Revised: 12/23/2013] [Accepted: 12/26/2013] [Indexed: 10/25/2022]
Abstract
The aim of this study was to develop a sensitive and environment-friendly method based on stir-bar sorptive extraction (SBSE) followed by thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) to determine 8 synthetic musks (musk ambrette, musk ketone, celestolide, tonalide, galaxolide, phantolide, traseolide, and cashmeran) in vegetables (lettuce, carrot, and pepper) and amended soil samples. In a first step sorptive extraction was studied both in the headspace (HSSE) and in the immerse mode (SBSE). The best results were obtained in the immersion mode which was further studied. The influence of the main factors: methanol (20%) and NaCl addition (0%), extraction temperature (40°C) and time (180 min), extraction solvent volume (9 mL) and stirring rate (600 rpm) on the efficiency of SBSE was evaluated by means of experimental designs. In the case of TD, desorption time (10 min), desorption temperature (300°C), cryo-focusing temperature (-30°C), vent flow (75 mL/min) and vent pressure (7.2 psi) were studied using both a fractioned factorial design and a central composite design (CCD). The method was validated in terms of apparent recoveries (AR%), method detection limits (MDLs) and precision at two different concentration levels. Although quantification using instrumental calibration rendered odd results in most of the cases, satisfactory recoveries (74-126%) were obtained in the case of matrix-matched calibration approach for all of the analytes and matrices studied at the two concentration levels evaluated. MDLs in the range of 0.01-0.8 ng/g and 0.01-1.1 ng/g were obtained for vegetables and amended soil samples, respectively. RSD values within 1-23% were obtained for all the analytes and matrices. Finally, the method was applied to the determination of musks in vegetable and amended soil samples.
Collapse
|
93
|
Bizkarguenaga E, Iparragirre A, Navarro P, Olivares M, Prieto A, Vallejo A, Zuloaga O. In-port derivatization after sorptive extractions. J Chromatogr A 2013; 1296:36-46. [DOI: 10.1016/j.chroma.2013.03.058] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2013] [Revised: 03/19/2013] [Accepted: 03/21/2013] [Indexed: 11/28/2022]
|
94
|
Vallejo A, Prieto A, Moeder M, Usobiaga A, Zuloaga O, Etxebarria N, Paschke A. Calibration and field test of the Polar Organic Chemical Integrative Samplers for the determination of 15 endocrine disrupting compounds in wastewater and river water with special focus on performance reference compounds (PRC). WATER RESEARCH 2013; 47:2851-2862. [PMID: 23517875 DOI: 10.1016/j.watres.2013.02.049] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2012] [Revised: 02/21/2013] [Accepted: 02/23/2013] [Indexed: 06/01/2023]
Abstract
In this work, home-made Polar Organic Chemical Integrative Samplers (POCIS) were studied for passive sampling of 15 endocrine disrupting compounds (4 alkylphenols and steroid hormones) in influent and effluent samples of wastewater treatment plants (WWTPs) as well as up- and downstream of the receiving river water. POCIS calibration at laboratory conditions was carried out using a continuous-flow calibration system. The influence of the exposure position of the POCIS within the calibration device, horizontal or vertical, to the water flow direction was evaluated. While the sampling rates of most of the target substances were not affected by the sampler position, for cis-ADT, E1, E2 and E3, the vertical position provided the highest analyte accumulation. Hence, the POCIS samplers were preferably exposed vertical to the water flow in overall experiments. Using the continuous-flow calibration device, lab-based sampling rates were determined for all the target compounds (RSBPA = 0.0326 L/d; RScisADT = 0.0800 L/d, RSE1 = 0.0398 L/d, RSEQ = 0.0516 L/d, RSTT = 0.0745 L/d, RSE2 = 0.0585 L/d, RSEE2 = 0.0406 L/d, RSNT = 0.0846 L/d, RSPG = 0.0478 L/d and RSE3 = 0.1468 L/d), except for DES, MeEE2, 4tOP, 4OP, 4NPs, where the uptake after 14 days POCIS exposure was found to be insignificant or indicated a no linear behaviour. Recoveries from POCIS extractions were in the range between 71 and 152% for most of the target analytes except for DES and E3 with around 59%. Good precision of the sampling procedure up till 20% was observed and limits of detection were at ng/L level. Two deuterated compounds ([(2)H3]-E2 and [(2)H4]-EQ) were successfully tested as performance reference compounds (PRC, [Formula: see text] = 0.0507 L/d and [Formula: see text] = 0.0543 L/d)). Finally, the POCIS samplers were tested for monitoring EDCs at two wastewater treatment plants, in Halle and Leipzig (Germany). BPA, E1, EQ, E2, MeEE2, NT, EE2, PG and E3 were quantified and their time-weighted average concentrations calculated on the basis of the lab-derived sampling rates were compared with the results based on conventional grab samples. While the influent concentration of BPA, cisADT, E1, TT, PG, EE2 reached the μg/L level, the rest of the target analytes were determined at ng/L. The analyte concentrations in the effluent never exceed ng/L level except for BPA. The concentration determined by spot sampling was partially lower (BPA, E1, TT) or comparable (EQ, E2, EE2, PG, E3) to the concentration obtained by POCIS using performance reference compounds (PRC).
Collapse
|
95
|
Cavalheiro J, Prieto A, Monperrus M, Etxebarria N, Zuloaga O. Determination of polycyclic and nitro musks in environmental water samples by means of microextraction by packed sorbents coupled to large volume injection-gas chromatography–mass spectrometry analysis. Anal Chim Acta 2013; 773:68-75. [DOI: 10.1016/j.aca.2013.02.036] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2012] [Revised: 01/28/2013] [Accepted: 02/22/2013] [Indexed: 10/27/2022]
|
96
|
Zuloaga O, Navarro P, Bizkarguenaga E, Iparraguirre A, Vallejo A, Olivares M, Prieto A. Overview of extraction, clean-up and detection techniques for the determination of organic pollutants in sewage sludge: A review. Anal Chim Acta 2012; 736:7-29. [DOI: 10.1016/j.aca.2012.05.016] [Citation(s) in RCA: 147] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2012] [Revised: 05/11/2012] [Accepted: 05/12/2012] [Indexed: 11/16/2022]
|
97
|
Iparraguirre A, Navarro P, Prieto A, Rodil R, Olivares M, Fernández LÁ, Zuloaga O. Membrane-assisted solvent extraction coupled to large volume injection–gas chromatography–mass spectrometry for the determination of a variety of endocrine disrupting compounds in environmental water samples. Anal Bioanal Chem 2012; 402:2897-907. [PMID: 22286125 DOI: 10.1007/s00216-012-5717-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2011] [Revised: 12/14/2011] [Accepted: 01/05/2012] [Indexed: 10/14/2022]
Abstract
Membrane-assisted solvent extraction coupled to large volume injection in a programmable temperature vaporisation injector using gas chromatography–mass spectrometry analysis was optimised for the simultaneous determination of a variety of endocrine disrupting compounds in environmental water samples (estuarine, river and wastewater). Among the analytes studied, certain hormones, alkylphenols and bisphenol A were included. The nature of membranes, extraction solvent, extraction temperature, solvent volume, extraction time, ionic strength and methanol addition were evaluated during the optimisation of the extraction. Matrix effects during the extraction step were studied in different environmental water samples: estuarine water, river water and wastewater (influent and effluent). Strong matrix effects were observed for most of the compounds in influent and effluent samples. Different approaches were studied in order to correct or minimise matrix effects, which included the use of deuterated analogues, matrix-matched calibration, standard addition calibration, dilution of the sample and clean-up of the extract using solid-phase extraction (SPE). The use of deuterated analogues corrected satisfactorily matrix effect for estuarine and effluent samples for most of the compounds. However, in the case of influent samples, standard addition calibration and dilution of the sample were the best approaches. The SPE clean-up provided similar recoveries to those obtained after correction with the corresponding deuterated analogue but better chromatographic signal was obtained in the case of effluent samples. Method detection limits in the 5-54 ng L(-1) range and precision, calculated as relative standard deviation, in the 2-25% range were obtained.
Collapse
|
98
|
Martinez P, Marco G, Perez D, Tomas M, Prieto A, Navarro J, Rodriguez J, Baeza M, Alvarez-Perea A. Baseline Serum Tryptase Levels in Patients who Suffered Anaphylaxis. J Allergy Clin Immunol 2012. [DOI: 10.1016/j.jaci.2011.12.245] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
99
|
Prez Alzate D, Marco G, Pineda R, Tornero P, Prieto A, Baeza M, Zubeldia J, Herrero T. Hypersensitivity Reactions To Monoclonal Antibodies: Desensitization Approach. J Allergy Clin Immunol 2012. [DOI: 10.1016/j.jaci.2011.12.529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
100
|
Prieto A, Rodil R, Quintana JB, Rodríguez I, Cela R, Möder M. Evaluation of low-cost disposable polymeric materials for sorptive extraction of organic pollutants in water samples. Anal Chim Acta 2011; 716:119-27. [PMID: 22284886 DOI: 10.1016/j.aca.2011.12.023] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2011] [Revised: 12/09/2011] [Accepted: 12/10/2011] [Indexed: 11/27/2022]
Abstract
The capabilities of four commercially available and low cost polymeric materials for the extraction of polar and non-polar contaminants (logK(ow)=-0.07-6.88, from caffeine to octocrylene, respectively) from water samples was compared. Tested sorbents were polyethersulphone, polypropylene and Kevlar, compared to polydimethylsiloxane as reference material. Parameters that affect the extraction process such as pH and ionic strength of the sample, extraction time and desorption conditions were thoroughly investigated. A set of experimental partition coefficients (K(pw)), at two different experimental conditions, was estimated for the best suited materials and compared with the theoretical octanol-water (K(ow)) partition coefficients of the analytes. Polyethersulphone displayed the largest extraction yields for both polar and non-polar analytes, with higher K(pw) and lower matrix effects than polydimethylsiloxane and polypropylene. Thus, a sorptive microextraction method, followed by large volume injection (LVI) gas chromatography-tandem mass spectrometry (GC-MS/MS), was proposed using the former sorbent (2 mg) for the simultaneous determination of model compounds in water samples. Good linearity (>0.99) was obtained for most of the analytes, except in the case of 4-nonylphenol (0.9466). Precision (n=4) at 50 and 500 ng L(-1) levels was in the 2-24% and limits of detection (LODs) were in the 0.6-25 ng L(-1) range for all the analytes studied.
Collapse
|