76
|
Phinikaridou A, Lacerda S, Lavin B, Andia ME, Smith A, Saha P, Botnar RM. Tropoelastin: A novel marker for plaque progression and instability. Circ Cardiovasc Imaging 2018; 11. [PMID: 30214669 DOI: 10.1161/circimaging.117.007303] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Background Elastolysis and ineffective elastogenesis favor the accumulation of tropoelastin, rather than cross-linked elastin, in atherosclerotic plaques. We developed gadolinium-labeled tropoelastin-specific magnetic resonance contrast agents (Gd-TESMAs) for tropoelastin imaging in animal models. Methods and Results Two peptides, VVGSPSAQDEASPLS and YPDHVQYTHY were selected to target tropoelastin. In vitro binding, relaxivity, and biodistribution experiments enabled characterization of the probes and selecting the best candidate for in vivo MRI. MRI was performed in atherosclerotic apolipoprotein E-deficient (ApoE-/-) mice and New Zealand white rabbits with stable and rupture-prone plaques using Gd-TESMA. Additionally, human carotid endarterectomy specimens were imaged ex vivo. The VVGSPSAQDEASPLS-based probe discriminated between tropoelastin and cross-linked elastin (64±7% vs 1±2%, P=0.001), had high in vitro relaxivity in solution (r1-free=11.7±0.6mM-1s-1, r1-bound to tropoelastin = 44±1mM-1s-1) and favorable pharmacokinetics. In vivo mice vascular enhancement (4wks=0.13±0.007mm2, 8wks=0.22±0.01mm2, 12wks=0.33±0.01mm2, P<0.001) and R1 relaxation rate (4wks=0.90±0.01 s-1, 8wks=1.40±0.03 s-1, 12wks=1.87±0.04s-1, P<0.001) increased with atherosclerosis progression after Gd-TESMA injection. Conversely, statin-treated (0.13±0.01mm2, R1 =1.37±0.03s-1) and control (0.10±0.005mm2, R1 =0.87±0.05s-1) mice showed less enhancement. Rupture-prone rabbit plaques had higher R1 relaxation rate compared with stale plaques (R1=2.26±0.1s-1vs R1=1.43±0.02s-1, P=0.001), after administration of Gd-TESMA that allowed detection of rupture-prone plaques with high sensitivity (84.4%) and specificity (92.3%). Increased vascular R1 relaxation rate was observed in carotid endarterectomy plaques after soaking (R1pre= 1.1±0.26 s-1 vs R1post= 3.0±0.1s-1, P=0.01). Ex vivo analyses confirmed the MRI findings and showed uptake of the contrast agent to be specific for tropoelastin. Conclusions MRI of tropoelastin provides a novel biomarker for atherosclerotic plaque progression and instability.
Collapse
|
77
|
Cruz G, Schneider T, Bruijnen T, Gaspar AS, Botnar RM, Prieto C. Accelerated magnetic resonance fingerprinting using soft-weighted key-hole (MRF-SOHO). PLoS One 2018; 13:e0201808. [PMID: 30092033 PMCID: PMC6084944 DOI: 10.1371/journal.pone.0201808] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2018] [Accepted: 07/23/2018] [Indexed: 11/28/2022] Open
Abstract
Object To develop a novel approach for highly accelerated Magnetic Resonance Fingerprinting (MRF) acquisition. Materials and methods The proposed method combines parallel imaging, soft-gating and key-hole approaches to highly accelerate MRF acquisition. Slowly varying flip angles (FA), commonly used during MRF acquisition, lead to a smooth change in the signal contrast of consecutive time-point images. This assumption enables sharing of high frequency data between different time-points, similar to what is done in some dynamic MR imaging methods such as key-hole. The proposed approach exploits this information using a SOft-weighted key-HOle (MRF-SOHO) reconstruction to achieve high acceleration factors and/or increased resolution without compromising image quality or increasing scan time. MRF-SOHO was validated on a standard T1/T2 phantom and in in-vivo brain acquisitions reconstructing T1, T2 and proton density parametric maps. Results Accelerated MRF-SOHO using less data per time-point and less time-point images enabled a considerable reduction in scan time (up to 4.6x), while obtaining similar T1 and T2 accuracy and precision when compared to zero-filled MRF reconstruction. For the same number of spokes and time-points, the proposed method yielded an enhanced performance in quantifying parameters than the zero-filled MRF reconstruction, which was verified with 2, 1 and 0.7 (sub-millimetre) resolutions. Conclusion The proposed MRF-SOHO enabled a 4.6x scan time reduction for an in-plane spatial resolution of 2x2 mm2 when compared to zero-filled MRF and enabled sub-millimetric (0.7x0.7 mm2) resolution MRF.
Collapse
|
78
|
Lavin B, Protti A, Lorrio S, Dong X, Phinikaridou A, Botnar RM, Shah A. MRI with gadofosveset: A potential marker for permeability in myocardial infarction. Atherosclerosis 2018; 275:400-408. [PMID: 29735362 PMCID: PMC6100880 DOI: 10.1016/j.atherosclerosis.2018.04.024] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/23/2017] [Revised: 03/27/2018] [Accepted: 04/18/2018] [Indexed: 12/23/2022]
Abstract
BACKGROUND AND AIMS Acute ischemia is associated with myocardial endothelial damage and microvessel formation, resulting in leakage of plasma albumin into the myocardial extravascular space. In this study, we tested whether an albumin-binding intravascular contrast agent (gadofosveset) allows for improved quantification of myocardial permeability compared to the conventional extracellular contrast agent Gd-DTPA using late gadolinium enhancement (LGE) and T1 mapping in vivo. METHODS MI was induced in C57BL/6 mice (n = 6) and cardiac magnetic resonance imaging (CMR) was performed at 3, 10 and 21 days post-MI using Gd-DTPA and 24 h later using gadofosveset. Functional, LGE and T1 mapping protocols were performed 45 min post-injection of the contrast agent. RESULTS LGE images showed that both contrast agents provided similar measurements of infarct area at all time points following MI. Importantly, the myocardial R1 measurements after administration of gadofosveset were higher in the acute phase-day 3 (R1 [s-1] = 6.29 ± 0.29) compared to the maturation phase-days 10 and 21 (R1 [s-1] = 4.76 ± 0.30 and 4.48 ± 0.14), suggesting that the uptake of this agent could be used to stage myocardial remodeling. No differences in myocardial R1 were observed after administration of Gd-DTPA at different time points post-MI (R1 [s-1] = 3d: 3.77 ± 0.37; 10d: 2.74 ± 0.06; 21d: 3.35 ± 0.26). The MRI results were validated by ex vivo histology that showed albumin leakage in the myocardium in the acute phase and microvessel formation at later stages. CONCLUSIONS We demonstrate the merits of an albumin-binding contrast agent for monitoring changes in myocardial permeability between acute ischemia and chronic post-MI myocardial remodeling.
Collapse
|
79
|
Nezafat M, Nakamori S, Basha TA, Fahmy AS, Hauser T, Botnar RM. Imaging sequence for joint myocardial T 1 mapping and fat/water separation. Magn Reson Med 2018; 81:486-494. [PMID: 30058096 PMCID: PMC6258274 DOI: 10.1002/mrm.27390] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2018] [Revised: 05/09/2018] [Accepted: 05/14/2018] [Indexed: 01/03/2023]
Abstract
Purpose To develop and evaluate an imaging sequence to simultaneously quantify the epicardial fat volume and myocardial T1 relaxation time. Methods We introduced a novel simultaneous myocardial T1 mapping and fat/water separation sequence (joint T1‐fat/water separation). Dixon reconstruction is performed on a dual‐echo data set to generate water/fat images. T1 maps are computed using the water images, whereas the epicardial fat volume is calculated from the fat images. A phantom experiment using vials with different T1/T2 values and a bottle of oil was performed. Additional phantom experiment using vials of mixed fat/water was performed to show the potential of this sequence to mitigate the effect of intravoxel fat on estimated T1 maps. In vivo evaluation was performed in 17 subjects. Epicardial fat volume, native myocardial T1 measurements and precision were compared among slice‐interleaved T1 mapping, Dixon, and the proposed sequence. Results In the first phantom, the proposed sequence separated oil from water vials and there were no differences in T1 of the fat‐free vials (P = .1). In the second phantom, the T1 error decreased from 22%, 36%, 57%, and 73% to 8%, 9%, 16%, and 26%, respectively. In vivo there was no difference between myocardial T1 values (1067 ± 17 ms versus 1077 ± 24 ms, P = .6). The epicardial fat volume was similar for both sequences (54.3 ± 33 cm3 versus 52.4 ± 32 cm3, P = .8). Conclusion The proposed sequence provides simultaneous quantification of native myocardial T1 and epicardial fat volume. This will eliminate the need for an additional sequence in the cardiac imaging protocol if both measurements are clinically indicated.
Collapse
|
80
|
Bustin A, Ginami G, Cruz G, Correia T, Ismail TF, Rashid I, Neji R, Botnar RM, Prieto C. Five-minute whole-heart coronary MRA with sub-millimeter isotropic resolution, 100% respiratory scan efficiency, and 3D-PROST reconstruction. Magn Reson Med 2018; 81:102-115. [PMID: 30058252 PMCID: PMC6617822 DOI: 10.1002/mrm.27354] [Citation(s) in RCA: 55] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2018] [Revised: 03/23/2018] [Accepted: 04/19/2018] [Indexed: 01/08/2023]
Abstract
Purpose To enable whole‐heart 3D coronary magnetic resonance angiography (CMRA) with isotropic sub‐millimeter resolution in a clinically feasible scan time by combining respiratory motion correction with highly accelerated variable density sampling in concert with a novel 3D patch‐based undersampled reconstruction (3D‐PROST). Methods An undersampled variable density spiral‐like Cartesian trajectory was combined with 2D image‐based navigators to achieve 100% respiratory efficiency and predictable scan time. 3D‐PROST reconstruction integrates structural information from 3D patch neighborhoods through sparse representation, thereby exploiting the redundancy of the 3D anatomy of the coronary arteries in an efficient low‐rank formulation. The proposed framework was evaluated in a static resolution phantom and in 10 healthy subjects with isotropic resolutions of 1.2 mm3 and 0.9 mm3 and undersampling factors of ×5 and ×9. 3D‐PROST was compared against fully sampled (1.2 mm3 only), conventional parallel imaging, and compressed sensing reconstructions. Results Phantom and in vivo (1.2 mm3) reconstructions were in excellent agreement with the reference fully sampled image. In vivo average acquisition times (min:s) were 7:57 ± 1:18 (×5) and 4:35 ± 0:44 (×9) for 0.9 mm3 resolution. Sub‐millimeter 3D‐PROST resulted in excellent depiction of the left and right coronary arteries including small branch vessels, leading to further improvements in vessel sharpness and visible vessel length in comparison with conventional reconstruction techniques. Image quality rated by 2 experts demonstrated that 3D‐PROST provides good image quality and is robust even at high acceleration factors. Conclusion The proposed approach enables free‐breathing whole‐heart 3D CMRA with isotropic sub‐millimeter resolution in <5 min and achieves improved coronary artery visualization in a short and predictable scan time.
Collapse
|
81
|
Botnar RM, Brangsch J, Reimann C, Janssen CHP, Razavi R, Hamm B, Makowski MR. In Vivo Molecular Characterization of Abdominal Aortic Aneurysms Using Fibrin-Specific Magnetic Resonance Imaging. J Am Heart Assoc 2018; 7:e007909. [PMID: 29848500 PMCID: PMC6015382 DOI: 10.1161/jaha.117.007909] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2017] [Accepted: 01/24/2018] [Indexed: 01/07/2023]
Abstract
BACKGROUND The incidence of abdominal aortic aneurysms (AAAs) will significantly increase during the next decade. Novel biomarkers, besides diameter, are needed for a better characterization of aneurysms and the estimation of the risk of rupture. Fibrin is a key protein in the formation of focal hematoma associated with the dissection of the aortic wall and the development of larger thrombi during the progression of AAAs. This study evaluated the potential of a fibrin-specific magnetic resonance (MR) probe for the in vivo characterization of the different stages of AAAs. METHODS AND RESULTS AAAs spontaneously developed in ApoE-/- mice following the infusion of angiotensin-II (Ang-II, 1 μg/kg-1·per minute). An established fibrin-specific molecular MR probe (EP2104R, 10 μmol/kg-1) was administered after 1 to 4 weeks following Ang-II infusion (n=8 per group). All imaging experiments were performed on a clinical 3T Achieva MR system with a microscopy coil (Philips Healthcare, Netherlands). The development of AAA-associated fibrin-rich hematoma and thrombi was assessed. The high signal generated by the fibrin probe enabled high-resolution MR imaging for an accurate assessment and quantification of the relative fibrin composition of focal hematoma and thrombi. Contrast-to-noise-ratios (CNRs) and R1-relaxation rates following the administration of the fibrin probe were in good agreement with ex vivo immunohistomorphometry (R2=0.83 and 0.85) and gadolinium concentrations determined by inductively coupled plasma mass spectroscopy (R2=0.78 and 0.72). CONCLUSIONS The fibrin-specific molecular MR probe allowed the delineation and quantification of changes in fibrin content in early and advanced AAAs. Fibrin MRI could provide a novel in vivo biomarker to improve the risk stratification of patients with aortic aneurysms.
Collapse
MESH Headings
- Angiotensin II
- Animals
- Aorta, Abdominal/diagnostic imaging
- Aorta, Abdominal/metabolism
- Aortic Aneurysm, Abdominal/chemically induced
- Aortic Aneurysm, Abdominal/diagnostic imaging
- Aortic Aneurysm, Abdominal/genetics
- Aortic Aneurysm, Abdominal/metabolism
- Disease Models, Animal
- Fibrin/metabolism
- Magnetic Resonance Imaging
- Male
- Mice, Inbred C57BL
- Mice, Knockout, ApoE
- Molecular Imaging/methods
- Predictive Value of Tests
Collapse
|
82
|
Correia T, Ginami G, Cruz G, Neji R, Rashid I, Botnar RM, Prieto C. Optimized respiratory-resolved motion-compensated 3D Cartesian coronary MR angiography. Magn Reson Med 2018; 80:2618-2629. [PMID: 29682783 PMCID: PMC6220806 DOI: 10.1002/mrm.27208] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2018] [Revised: 03/13/2018] [Accepted: 03/14/2018] [Indexed: 11/29/2022]
Abstract
Purpose To develop a robust and efficient reconstruction framework that provides high‐quality motion‐compensated respiratory‐resolved images from free‐breathing 3D whole‐heart Cartesian coronary magnetic resonance angiography (CMRA) acquisitions. Methods Recently, XD‐GRASP (eXtra‐Dimensional Golden‐angle RAdial Sparse Parallel MRI) was proposed to achieve 100% scan efficiency and provide respiratory‐resolved 3D radial CMRA images by exploiting sparsity in the respiratory dimension. Here, a reconstruction framework for Cartesian CMRA imaging is proposed, which provides respiratory‐resolved motion‐compensated images by incorporating 2D beat‐to‐beat translational motion information to increase sparsity in the respiratory dimension. The motion information is extracted from interleaved image navigators and is also used to compensate for 2D translational motion within each respiratory phase. The proposed Optimized Respiratory‐resolved Cartesian Coronary MR Angiography (XD‐ORCCA) method was tested on 10 healthy subjects and 2 patients with cardiovascular disease, and compared against XD‐GRASP. Results The proposed XD‐ORCCA provides high‐quality respiratory‐resolved images, allowing clear visualization of the right and left coronary arteries, even for irregular breathing patterns. Compared with XD‐GRASP, the proposed method improves the visibility and sharpness of both coronaries. Significant differences (p < .05) in visible vessel length and proximal vessel sharpness were found between the 2 methods. The XD‐GRASP method provides good‐quality images in the absence of intraphase motion. However, motion blurring is observed in XD‐GRASP images for respiratory phases with larger motion amplitudes and subjects with irregular breathing patterns. Conclusion A robust respiratory‐resolved motion‐compensated framework for Cartesian CMRA has been proposed and tested in healthy subjects and patients. The proposed XD‐ORCCA provides high‐quality images for all respiratory phases, independently of the regularity of the breathing pattern.
Collapse
|
83
|
Correia T, Cruz G, Schneider T, Botnar RM, Prieto C. Technical note: Accelerated nonrigid motion-compensated isotropic 3D coronary MR angiography. Med Phys 2017; 45:214-222. [PMID: 29131353 PMCID: PMC5814733 DOI: 10.1002/mp.12663] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2017] [Revised: 10/09/2017] [Accepted: 11/01/2017] [Indexed: 12/15/2022] Open
Abstract
PURPOSE To develop an accelerated and nonrigid motion-compensated technique for efficient isotropic 3D whole-heart coronary magnetic resonance angiography (CMRA) with Cartesian acquisition. METHODS Highly efficient whole-heart 3D CMRA was achieved by combining image reconstruction from undersampled data using compressed sensing (CS) with a nonrigid motion compensation framework. Undersampled acquisition was performed using a variable-density Cartesian trajectory with radial order (VD-CAPR). Motion correction was performed in two steps: beat-to-beat 2D translational correction with motion estimated from interleaved image navigators, and bin-to-bin 3D nonrigid correction with motion estimated from respiratory-resolved images reconstructed from undersampled 3D CMRA data using CS. Nonrigid motion fields were incorporated into an undersampled motion-compensated reconstruction, which combines CS with the general matrix description formalism. The proposed approach was tested on 10 healthy subjects and compared against a conventional twofold accelerated 5-mm navigator-gated and tracked acquisition. RESULTS The proposed method achieves isotropic 1.2-mm Cartesian whole-heart CMRA in 5 min ± 1 min (~8× acceleration). The proposed approach provides good-quality images of the left and right coronary arteries, comparable to those of a twofold accelerated navigator-gated and tracked acquisition, but scan time was up to about four times faster. For both coronaries, no significant differences (P > 0.05) in vessel sharpness and length were found between the proposed method and reference scan. CONCLUSION The feasibility of a highly efficient motion-compensated reconstruction framework for accelerated 3D CMRA has been demonstrated in healthy subjects. Further investigation is required to assess the clinical value of the method.
Collapse
|
84
|
Ginami G, Neji R, Rashid I, Chiribiri A, Ismail TF, Botnar RM, Prieto C. 3D whole-heart phase sensitive inversion recovery CMR for simultaneous black-blood late gadolinium enhancement and bright-blood coronary CMR angiography. J Cardiovasc Magn Reson 2017; 19:94. [PMID: 29178893 PMCID: PMC5702978 DOI: 10.1186/s12968-017-0405-z] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2017] [Accepted: 11/06/2017] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND Phase sensitive inversion recovery (PSIR) applied to late gadolinium enhancement (LGE) imaging is widely used in clinical practice. However, conventional 2D PSIR LGE sequences provide sub-optimal contrast between scar tissue and blood pool, rendering the detection of subendocardial infarcts and scar segmentation challenging. Furthermore, the acquisition of a low flip angle reference image doubles the acquisition time without providing any additional diagnostic information. The purpose of this study was to develop and test a novel 3D whole-heart PSIR-like framework, named BOOST, enabling simultaneous black-blood LGE assessment and bright-blood visualization of cardiac anatomy. METHODS The proposed approach alternates the acquisition of a 3D volume preceded by a T2-prepared Inversion Recovery (T2Prep-IR) module (magnitude image) with the acquisition of a T2-prepared 3D volume (reference image). The two volumes (T2Prep-IR BOOST and bright-blood T2Prep BOOST) are combined in a PSIR-like reconstruction to obtain a complementary 3D black-blood volume for LGE assessment (PSIR BOOST). The black-blood PSIR BOOST and the bright-blood T2Prep BOOST datasets were compared to conventional clinical sequences for scar detection and coronary CMR angiography (CMRA) in 18 patients with a spectrum of cardiovascular disease (CVD). RESULTS Datasets from 12 patients were quantitatively analysed. The black-blood PSIR BOOST dataset provided statistically improved contrast to noise ratio (CNR) between blood and scar when compared to a clinical 2D PSIR sequence (15.8 ± 3.3 and 4.1 ± 5.6, respectively). Overall agreement in LGE depiction was found between 3D black-blood PSIR BOOST and clinical 2D PSIR acquisitions, with 11/12 PSIR BOOST datasets considered diagnostic. The bright-blood T2Prep BOOST dataset provided high quality depiction of the proximal coronary segments, with improvement of visual score when compared to a clinical CMRA sequence. Acquisition time of BOOST (~10 min), providing information on both LGE uptake and heart anatomy, was comparable to that of a clinical single CMRA sequence. CONCLUSIONS The feasibility of BOOST for simultaneous black-blood LGE assessment and bright-blood coronary angiography was successfully tested in patients with cardiovascular disease. The framework enables free-breathing multi-contrast whole-heart acquisitions with 100% scan efficiency and predictable scan time. Complementary information on 3D LGE and heart anatomy are obtained reducing examination time.
Collapse
|
85
|
Nezafat M, Ramos IT, Henningsson M, Protti A, Basha T, Botnar RM. Improved segmented modified Look-Locker inversion recovery T1 mapping sequence in mice. PLoS One 2017; 12:e0187621. [PMID: 29121086 PMCID: PMC5679534 DOI: 10.1371/journal.pone.0187621] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2017] [Accepted: 10/04/2017] [Indexed: 12/02/2022] Open
Abstract
Object To develop and evaluate a 2D modified Look-Locker (MOLLI) for high-resolution T1 mapping in mice using a 3T MRI scanner. Materials and methods To allow high-resolution T1 mapping in mice at high heart rates a multi-shot ECG-triggered 2D MOLLI sequence was developed. In the proposed T1 mapping sequence the optimal number of sampling points and pause cardiac cycles following an initial adiabatic inversion pulse was investigated in a phantom. Seven native control and eight mice, 3 days post myocardial infarction (MI) after administration of gadolinium were scanned. Two experienced readers graded the visual T1 map quality. Results In T1 phantoms, there were no significant differences (<0.4% error) between 12, 15 and 20 pause cardiac cycles (p = 0.1, 0.2 and 0.6 respectively) for 8 acquisition cardiac cycles for 600bpm in comparison to the conventional inversion recovery spin echo T1 mapping sequence for short T1’s (<600 ms). Subsequently, all in-vivo scans were performed with 8 data acquisitions and 12 pause cardiac cycles to minimize scan time. The mean native T1 value of myocardium in control animal was 820.5±52 ms. The post-contrast T1 measured 3 days after MI in scar was 264±59 ms and in healthy myocardium was 512±62 ms. The Bland-Altman analysis revealed mean difference of only -1.06% of infarct size percentage between T1 maps and LGE. Conclusions A multi-shot 2D MOLLI sequence has been presented that allows reliable measurement of high spatial resolution T1 maps in mice for heart rates up to 600bpm.
Collapse
|
86
|
Holtackers RJ, Chiribiri A, Schneider T, Higgins DM, Botnar RM. Dark-blood late gadolinium enhancement without additional magnetization preparation. J Cardiovasc Magn Reson 2017; 19:64. [PMID: 28835250 PMCID: PMC5568308 DOI: 10.1186/s12968-017-0372-4] [Citation(s) in RCA: 49] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2017] [Accepted: 07/11/2017] [Indexed: 01/14/2023] Open
Abstract
BACKGROUND This study evaluates a novel dark-blood late gadolinium enhancement (LGE) cardiovascular magnetic resonance imaging (CMR) method, without using additional magnetization preparation, and compares it to conventional bright-blood LGE, for the detection of ischaemic myocardial scar. LGE is able to clearly depict myocardial infarction and macroscopic scarring from viable myocardium. However, due to the bright signal of adjacent left ventricular blood, the apparent volume of scar tissue can be significantly reduced, or even completely obscured. In addition, blood pool signal can mimic scar tissue and lead to false positive observations. Simply nulling the blood magnetization by choosing shorter inversion times, leads to a negative viable myocardium signal that appears equally as bright as scar due to the magnitude image reconstruction. However, by combining blood magnetization nulling with the extended grayscale range of phase-sensitive inversion-recovery (PSIR), a darker blood signal can be achieved whilst a dark myocardium and bright scar signal is preserved. METHODS LGE was performed in nine male patients (63 ± 11y) using a PSIR pulse sequence, with both conventional viable myocardium nulling and left ventricular blood nulling, in a randomized order. Regions of interest were drawn in the left ventricular blood, viable myocardium, and scar tissue, to assess contrast-to-noise ratios. Maximum scar transmurality, scar size, circumferential scar angle, and a confidence score for scar detection and maximum transmurality were also assessed. Bloch simulations were performed to simulate the magnetization levels of the left ventricular blood, viable myocardium, and scar tissue. RESULTS Average scar-to-blood contrast was significantly (p < 0.001) increased by 99% when nulling left ventricular blood instead of viable myocardium, while scar-to-myocardium contrast was maintained. Nulling left ventricular blood also led to significantly (p = 0.038) higher expert confidence in scar detection and maximum transmurality. No significant changes were found in scar transmurality (p = 0.317), normalized scar size (p = 0.054), and circumferential scar angle (p = 0.117). CONCLUSIONS Nulling left ventricular blood magnetization for PSIR LGE leads to improved scar-to-blood contrast and increased expert confidence in scar detection and scar transmurality. As no additional magnetization preparation is used, clinical application on current MR systems is readily available without the need for extensive optimizations, software modifications, and/or additional training.
Collapse
|
87
|
Ginami G, Neji R, Phinikaridou A, Whitaker J, Botnar RM, Prieto C. Simultaneous bright- and black-blood whole-heart MRI for noncontrast enhanced coronary lumen and thrombus visualization. Magn Reson Med 2017; 79:1460-1472. [PMID: 28722267 PMCID: PMC5811778 DOI: 10.1002/mrm.26815] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2017] [Revised: 06/07/2017] [Accepted: 06/08/2017] [Indexed: 12/18/2022]
Abstract
PURPOSE To develop a 3D whole-heart Bright-blood and black-blOOd phase SensiTive (BOOST) inversion recovery sequence for simultaneous noncontrast enhanced coronary lumen and thrombus/hemorrhage visualization. METHODS The proposed sequence alternates the acquisition of two bright-blood datasets preceded by different preparatory pulses to obtain variations in blood/myocardium contrast, which then are combined in a phase-sensitive inversion recovery (PSIR)-like reconstruction to obtain a third, coregistered, black-blood dataset. The bright-blood datasets are used for both visualization of the coronary lumen and motion estimation, whereas the complementary black-blood dataset potentially allows for thrombus/hemorrhage visualization. Furthermore, integration with 2D image-based navigation enables 100% scan efficiency and predictable scan times. The proposed sequence was compared to conventional coronary MR angiography (CMRA) and PSIR sequences in a standardized phantom and in healthy subjects. Feasibility for thrombus depiction was tested ex vivo. RESULTS With BOOST, the coronary lumen is visualized with significantly higher (P < 0.05) contrast-to-noise ratio and vessel sharpness when compared to conventional CMRA. Furthermore, BOOST showed effective blood signal suppression as well as feasibility for thrombus visualization ex vivo. CONCLUSION A new PSIR sequence for noncontrast enhanced simultaneous coronary lumen and thrombus/hemorrhage detection was developed. The sequence provided improved coronary lumen depiction and showed potential for thrombus visualization. Magn Reson Med 79:1460-1472, 2018. © 2017 International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Collapse
|
88
|
Jansen CHP, Reimann C, Brangsch J, Botnar RM, Makowski MR. In vivo MR-angiography for the assessment of aortic aneurysms in an experimental mouse model on a clinical MRI scanner: Comparison with high-frequency ultrasound and histology. PLoS One 2017; 12:e0178682. [PMID: 28582441 PMCID: PMC5459432 DOI: 10.1371/journal.pone.0178682] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2017] [Accepted: 05/17/2017] [Indexed: 11/18/2022] Open
Abstract
BACKGROUND MR-angiography currently represents one of the clinical reference-standards for the assessment of aortic-dimensions. For experimental research in mice, dedicated preclinical high-field MRI scanners are used in most studies. This type of MRI scanner is not available in most institutions. The aim of this study was to evaluate the potential of MR-angiography performed on a clinical MR scanner for the assessment of aortic aneurysms in an experimental mouse model, compared to a preclinical high-resolution ultrasound imaging system and histopathology. METHODS All in vivo MR imaging was performed with a clinical 3T MRI system (Philips Achieva) equipped with a clinical gradient system in combination with a single-loop surface-coil (47 mm). All MR sequences were based on clinically used sequences. For ultrasound, a dedicated preclinical high-resolution system (30 MHz linear transducer, Vevo770, VisualSonics) was used. All imaging was performed with an ApoE knockout mouse-model for aortic aneurysms. Histopathology was performed as reference-standard at all stages of aneurysm development. RESULTS MR-angiography on a clinical 3T system enabled the clear visualization of the aortic lumen and aneurysmal dilation at different stages of aneurysm development. A close correlation (R2 = 0.98; p < 0.001) with histological area measurements was found. Additionally, a good agreement between MR and ultrasound area measurements in systole (R2 = 0.91; p < 0.001) and diastole (R2 = 0.94; p < 0.001) were measured. Regarding interobserver reproducibility, MRI measurements yielded a smaller 95% confidence interval and a closer interreader correlation compared to ultrasound measurements (-0.37-0.46; R2 = 0.97 vs. -0.78-0.88; R2 = 0.87). CONCLUSION This study demonstrates that MR-angiography, performed on a clinical 3T MR scanner, enables the reliable detection and quantification of the aortic dilatation at different stages of aneurysm development in an experimental mouse model.
Collapse
|
89
|
Stuber M, Botnar RM. CATCHing the High-Risk Coronary Plaques by Magnetic Resonance Imaging. JACC Cardiovasc Imaging 2017; 10:649-651. [DOI: 10.1016/j.jcmg.2016.07.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/06/2016] [Accepted: 07/07/2016] [Indexed: 10/20/2022]
|
90
|
Li H, Harriss BI, Phinikaridou A, Lacerda S, Ramniceanu G, Doan BT, Ho KL, Chan CF, Lo WS, Botnar RM, Lan R, Richard C, Law GL, Long NJ, Wong KL. Gadolinium and Platinum in Tandem: Real-time Multi-Modal Monitoring of Drug Delivery by MRI and Fluorescence Imaging. Nanotheranostics 2017; 1:186-195. [PMID: 29071187 PMCID: PMC5646715 DOI: 10.7150/ntno.18619] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2016] [Accepted: 04/11/2017] [Indexed: 12/25/2022] Open
Abstract
A novel dual-imaging cisplatin-carrying molecular cargo capable of performing simultaneous optical and MR imaging is reported herein. This long-lasting MRI contrast agent (r1 relaxivity of 23.4 mM-1s-1 at 3T, 25 oC) is a photo-activated cisplatin prodrug (PtGdL) which enables real-time monitoring of anti-cancer efficacy. PtGdL is a model for monitoring the drug delivery and anti-cancer efficacy by MRI with a much longer retention time (24 hours) in several organs such as renal cortex and spleen than GdDOTA and its motif control GdL. Upon complete release of cisplatin, all PtGdL is converted to GdL enabling subsequent MRI analyses of therapy efficacy within its reasonably short clearance time of 4 hours. There is also responsive fluorescence enhancement for monitoring by photon-excitation.
Collapse
|
91
|
Nordio G, Henningsson M, Chiribiri A, Villa ADM, Schneider T, Botnar RM. 3D myocardial T 1 mapping using saturation recovery. J Magn Reson Imaging 2017; 46:218-227. [PMID: 28152227 PMCID: PMC5518207 DOI: 10.1002/jmri.25575] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2016] [Accepted: 11/18/2016] [Indexed: 12/25/2022] Open
Abstract
Purpose To propose a 3D quantitative high‐resolution T1 mapping technique, called 3D SASHA (saturation‐recovery single‐shot acquisition), which combines a saturation recovery pulse with 1D‐navigator‐based‐respiratory motion compensation to acquire the whole volume of the heart in free breathing. The sequence was tested and validated both in a T1 phantom and in healthy subjects. Materials and Methods The 3D SASHA method was implemented on a 1.5T scanner. A diaphragmatic navigator was used to allow free‐breathing acquisition and the images were acquired with a resolution of 1.4 × 1.4 × 8 mm3. For assessment of accuracy and precision the sequence was compared with the reference gold‐standard inversion‐recovery spin echo (IRSE) pulse sequence in a T1 phantom, while for the in vivo studies (10 healthy volunteers) 3D SASHA was compared with the clinically used 2D MOLLI (3‐3‐5) and 2D SASHA protocols. Results There was good agreement between the T1 values measured in a T1 phantom with 3D SASHA and the reference IRSE pulse sequences (1111.6 ± 31 msec vs. 1123.6 ± 8 msec, P = 0.9947). Mean and standard deviation of the myocardial T1 values in healthy subjects measured with 2D MOLLI, 2D SASHA, and 3D SASHA sequences were 881 ± 40 msec, 1181.3 ± 32 msec, and 1153.6 ± 28 msec respectively. Conclusion The proposed 3D SASHA sequence allows for high‐resolution free‐breathing whole‐heart T1‐mapping with T1 values in good agreement with the 2D SASHA and improved precision. Level of Evidence: 2 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:218–227
Collapse
|
92
|
Brangsch J, Reimann C, Collettini F, Buchert R, Botnar RM, Makowski MR. Molecular Imaging of Abdominal Aortic Aneurysms. Trends Mol Med 2017; 23:150-164. [PMID: 28110838 DOI: 10.1016/j.molmed.2016.12.002] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2016] [Revised: 12/06/2016] [Accepted: 12/11/2016] [Indexed: 12/21/2022]
Abstract
Abdominal aortic aneurysms (AAAs) represent a vascular disease with severe complications. AAAs are currently the overall 10th leading cause of death in western countries and their incidence is rising. Although different diagnostic techniques are currently available in clinical practice, including ultrasound (US), magnetic resonance imaging (MRI), and computed tomography (CT), imaging-based prediction of life-threatening complications such as aneurysm-rupture remains challenging. Molecular imaging provides a novel diagnostic approach for in vivo visualization of biological processes and pathological alterations at a cellular and molecular level. Its overall aim is to improve our understanding of disease pathogenesis and to facilitate novel diagnostic pathways. This review outlines recent preclinical and clinical developments in molecular MRI, positron emission tomography (PET), and single-photon emission computed tomography (SPECT) for imaging of AAAs.
Collapse
|
93
|
Phinikaridou A, Andia ME, Lavin B, Smith A, Saha P, Botnar RM. Increased Vascular Permeability Measured With an Albumin-Binding Magnetic Resonance Contrast Agent Is a Surrogate Marker of Rupture-Prone Atherosclerotic Plaque. Circ Cardiovasc Imaging 2016; 9:e004910. [PMID: 27940955 PMCID: PMC5388187 DOI: 10.1161/circimaging.116.004910] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/29/2016] [Accepted: 09/30/2016] [Indexed: 12/21/2022]
Abstract
BACKGROUND Compromised structural integrity of the endothelium and higher microvessel density increase vascular permeability. We investigated whether vascular permeability measured in vivo by magnetic resonance imaging using the albumin-binding contrast agent, gadofosveset, is a surrogate marker of rupture-prone atherosclerotic plaque in a rabbit model. METHODS AND RESULTS New Zealand white rabbits (n=10) were rendered atherosclerotic by cholesterol-diet and endothelial denudation. Plaque rupture was triggered with Russell's viper venom and histamine. Animals were imaged pre-triggering, at 3 and 12 weeks, to quantify plaque area, vascular permeability, vasodilation, and stiffness and post-triggering to identify thrombus. Plaques identified on the pretrigger scans were classified as stable or rupture-prone based on the absence or presence of thrombus on the corresponding post-trigger magnetic resonance imaging, respectively. All rabbits had developed atherosclerosis, and 60% had ruptured plaques. Rupture-prone plaques had higher vessel wall relaxation rate (R1; 2.30±0.5 versus 1.86±0.3 s-1; P<0.001), measured 30 minutes after gadofosveset administration, and higher R1/plaque area ratio (0.70±0.06 versus 0.47±0.02, P= 0.01) compared with stable plaque at 12 weeks. Rupture-prone plaques had higher percent change in R1 between the 3 and 12 weeks compared with stable plaque (50.80±7.2% versus 14.22±2.2%; P<0.001). Immunohistochemistry revealed increased vessel wall albumin and microvessel density in diseased aortas and especially in ruptured plaque. Electron microscopy showed lack of structural integrity in both luminal and microvascular endothelium in diseased vessels. Functionally, the intrinsic vasodilation of the vessel wall decreased at 12 weeks compared with 3 weeks (18.60±1.0% versus 23.43±0.8%; P<0.001) and in rupture-prone compared with stable lesions (16.40±2.0% versus 21.63±1.2%; P<0.001). Arterial stiffness increased at 12 weeks compared with 3 weeks (5.00±0.1 versus 2.53±0.2 m/s; P<0.001) both in animals with stable and rupture-prone lesions. CONCLUSIONS T1 mapping using an albumin-binding contrast agent (gadofosveset) could quantify the changes in vascular permeability associated with atherosclerosis progression and rupture-prone plaques.
Collapse
|
94
|
Tandon A, James L, Henningsson M, Botnar RM, Potersnak A, Greil GF, Hussain T. A clinical combined gadobutrol bolus and slow infusion protocol enabling angiography, inversion recovery whole heart, and late gadolinium enhancement imaging in a single study. J Cardiovasc Magn Reson 2016; 18:66. [PMID: 27716273 PMCID: PMC5052797 DOI: 10.1186/s12968-016-0285-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2016] [Accepted: 09/24/2016] [Indexed: 12/28/2022] Open
Abstract
BACKGROUND The use of gadolinium contrast agents in cardiovascular magnetic resonance is well-established and serves to improve both vascular imaging as well as enable late gadolinium enhancement (LGE) imaging for tissue characterization. Currently, gadofosveset trisodium, an intravascular contrast agent, combined with a three-dimensional inversion recovery balanced steady state free precession (3D IR bSSFP) sequence, is commonly used in pediatric cardiac imaging and yields excellent vascular imaging, but cannot be used for late gadolinium enhancement. Gadofosveset use remains limited in clinical practice, and manufacture was recently halted, thus an alternative is needed to allow 3D IR bSSFP and LGE in the same study. METHODS Here we propose a protocol to give a bolus of 0.1 mL/kg = 0.1 mmol/kg gadobutrol (GADAVIST/GADOVIST) for time-resolved magnetic resonance angiography (MRA). Subsequently, 0.1 mmol/kg is diluted up to 5 or 7.5 mL with saline and then loaded into intravenous tubing connected to the patient. A 0.5 mL short bolus is infused, then a slow infusion is given at 0.02 or 0.03 mL/s. Image navigated (iNAV) 3D IR bSSFP imaging is initiated 45-60 s after the initiation of the infusion, with a total image acquisition time of ~5 min. If necessary, LGE imaging using phase sensitive inversion recovery reconstruction (PSIR) is performed at 10 min after the infusion is initiated. RESULTS We have successfully performed the above protocol with good image quality on 10 patients with both time-resolved MRA and 3D IR bSSFP iNAV imaging. Our initial attempts to use pencil beam respiratory navigation failed due to signal labeling in the liver by the navigator. We have also performed 2D PSIR LGE successfully, with both LGE positive and LGE negative results. CONCLUSION A bolus of gadobutrol, followed later by a slow infusion, allows time-resolved MRA, 3D IR bSSFP using the iNAV navigation technique, and LGE imaging, all in a single study with a single contrast agent.
Collapse
|
95
|
Nezafat M, Henningsson M, Ripley DP, Dedieu N, Greil G, Greenwood JP, Börnert P, Plein S, Botnar RM. Coronary MR angiography at 3T: fat suppression versus water-fat separation. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2016; 29:733-8. [PMID: 27038934 PMCID: PMC5033991 DOI: 10.1007/s10334-016-0550-7] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/19/2015] [Revised: 03/08/2016] [Accepted: 03/11/2016] [Indexed: 01/17/2023]
Abstract
Objectives To compare Dixon water-fat suppression with spectral pre-saturation with inversion recovery (SPIR) at 3T for coronary magnetic resonance angiography (MRA) and to demonstrate the feasibility of fat suppressed coronary MRA at 3T without administration of a contrast agent. Materials and methods Coronary MRA with Dixon water-fat separation or with SPIR fat suppression was compared on a 3T scanner equipped with a 32-channel cardiac receiver coil. Eight healthy volunteers were examined. Contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), right coronary artery (RCA), and left anterior descending (LAD) coronary artery sharpness and length were measured and statistically compared. Two experienced cardiologists graded the visual image quality of reformatted Dixon and SPIR images (1: poor quality to 5: excellent quality). Results Coronary MRA images in healthy volunteers showed improved contrast with the Dixon technique compared to SPIR (CNR blood-fat: Dixon = 14.9 ± 2.9 and SPIR = 13.9 ± 2.1; p = 0.08, CNR blood-myocardium: Dixon = 10.2 ± 2.7 and SPIR = 9.11 ± 2.6; p = 0.1). The Dixon method led to similar fat suppression (fat SNR with Dixon: 2.1 ± 0.5 vs. SPIR: 2.4 ± 1.2, p = 0.3), but resulted in significantly increased SNR of blood (blood SNR with Dixon: 19.9 ± 4.5 vs. SPIR: 15.5 ± 3.1, p < 0.05). This means the residual fat signal is slightly lower with the Dixon compared to the SIPR technique (although not significant), while the SNR of blood is significantly higher with the Dixon technique. Vessel sharpness of the RCA was similar for Dixon and SPIR (57 ± 7 % vs. 56 ± 9 %, p = 0.2), while the RCA visualized vessel length was increased compared to SPIR fat suppression (107 ± 21 vs. 101 ± 21 mm, p < 0.001). For the LAD, vessel sharpness (50 ± 13 % vs. 50 ± 7 %, p = 0.4) and vessel length (92 ± 46 vs. 90 ± 47 mm, p = 0.4) were similar with both techniques. Consequently, the Dixon technique resulted in an improved visual score of the coronary arteries in the water fat separated images of healthy subjects (RCA: 4.6 ± 0.5 vs. 4.1 ± 0.7, p = 0.01, LAD: 4.1 ± 0.7 vs. 3.5 ± 0.8, p = 0.007). Conclusions Dixon water-fat separation can significantly improve coronary artery image quality without the use of a contrast agent at 3T.
Collapse
|
96
|
Botnar RM, Kim WY. Coronary MR Imaging: Moving From Lumenography to Plaque Assessment. JACC Cardiovasc Imaging 2015; 8:1153-1155. [PMID: 26481840 DOI: 10.1016/j.jcmg.2015.08.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/30/2015] [Revised: 08/04/2015] [Accepted: 08/06/2015] [Indexed: 11/29/2022]
|
97
|
Lavin B, Phinikaridou A, Lorrio S, Zaragoza C, Botnar RM. Monitoring vascular permeability and remodeling after endothelial injury in a murine model using a magnetic resonance albumin-binding contrast agent. Circ Cardiovasc Imaging 2015; 8:CIRCIMAGING.114.002417. [PMID: 25873720 PMCID: PMC4405074 DOI: 10.1161/circimaging.114.002417] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
BACKGROUND Despite the beneficial effects of vascular interventions, these procedures may damage the endothelium leading to increased vascular permeability and remodeling. Re-endothelialization of the vessel wall, with functionally and structurally intact cells, is controlled by endothelial nitric oxide synthase (NOS3) and is crucial for attenuating adverse effects after injury. We investigated the applicability of the albumin-binding MR contrast agent, gadofosveset, to noninvasively monitor focal changes in vascular permeability and remodeling, after injury, in NOS3-knockout (NOS3(-/-)) and wild-type (WT) mice in vivo. METHODS AND RESULTS WT and NOS3(-/-) mice were imaged at 7, 15, and 30 days after aortic denudation or sham-surgery. T1 mapping (R1=1/T1, s(-1)) and delayed-enhanced MRI were used as measurements of vascular permeability (R1) and remodeling (vessel wall enhancement, mm(2)) after gadofosveset injection, respectively. Denudation resulted in higher vascular permeability and vessel wall enhancement 7 days after injury in both strains compared with sham-operated animals. However, impaired re-endothelialization and increased neovascularization in NOS3(-/-) mice resulted in significantly higher R1 at 15 and 30 days post injury compared with WT mice that showed re-endothelialization and lack of neovascularization (R1 [s(-1)]=15 days: NOS3 (-/-)4.02 [interquartile range, IQR, 3.77-4.41] versus WT2.39 [IQR, 2.35-2.92]; 30 days: NOS3 (-/-)4.23 [IQR, 3.94-4.68] versus WT2.64 [IQR, 2.33-2.80]). Similarly, vessel wall enhancement was higher in NOS3(-/-) but recovered in WT mice (area [mm(2)]=15 days: NOS3 (-/-)5.20 [IQR, 4.68-6.80] versus WT2.13 [IQR, 0.97-3.31]; 30 days: NOS3 (-/-)7.35 [IQR, 5.66-8.61] versus WT1.60 [IQR, 1.40-3.18]). Ex vivo histological studies corroborated the MRI findings. CONCLUSIONS We demonstrate that increased vascular permeability and remodeling, after injury, can be assessed noninvasively using an albumin-binding MR contrast agent and may be used as surrogate markers for evaluating the healing response of the vessel wall after injury.
Collapse
|
98
|
Nörenberg D, Ebersberger HU, Diederichs G, Hamm B, Botnar RM, Makowski MR. Molecular magnetic resonance imaging of atherosclerotic vessel wall disease. Eur Radiol 2015; 26:910-20. [DOI: 10.1007/s00330-015-3881-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2014] [Revised: 04/27/2015] [Accepted: 06/08/2015] [Indexed: 11/29/2022]
|
99
|
Botnar RM, Ebersberger H, Noerenberg D, Jansen CHP, Wiethoff AJ, Schuster A, Kasner M, Walter TC, Knobloch G, Hoppe P, Diederichs G, Hamm B, Makowski MR. Molecular imaging in cardiovascular diseases. ROFO-FORTSCHR RONTG 2015; 36:92-101. [PMID: 25585260 DOI: 10.1055/s-0034-1385451] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
Cardiovascular diseases remain the leading cause of morbidity and mortality in industrialized and developing countries. In clinical practice, the in-vivo identification of atherosclerotic lesions, which can lead to complications such as heart attack or stroke, remains difficult. Imaging techniques provide the reference standard for the detection of clinically significant atherosclerotic changes in the coronary and carotid arteries. The assessment of the luminal narrowing is feasible, while the differentiation of stable and potentially unstable or vulnerable atherosclerotic plaques is currently not possible using non-invasive imaging. With high spatial resolution and high soft tissue contrast, magnetic resonance imaging (MRI) is a suitable method for the evaluation of the thin arterial wall. In clinical practice, native MRI of the vessel wall already allows the differentiation and characterization of components of atherosclerotic plaques in the carotid arteries and the aorta. Additional diagnostic information can be gained by the use of non-specific MRI contrast agents. With the development of targeted molecular probes, that highlight specific molecules or cells, pathological processes can be visualized at a molecular level with high spatial resolution. In this review article, the development of pathophysiological changes leading to the development of the arterial wall are introduced and discussed. Additionally, principles of contrast enhanced imaging with non-specific contrast agents and molecular probes will be discussed and latest developments in the field of molecular imaging of the vascular wall will be introduced.
Collapse
|
100
|
Lavin B, Phinikaridou A, Henningsson M, Botnar RM. Current Development of Molecular Coronary Plaque Imaging using Magnetic Resonance Imaging towards Clinical Application. CURRENT CARDIOVASCULAR IMAGING REPORTS 2014. [DOI: 10.1007/s12410-014-9309-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|