151
|
Brown WJ, Skeiky YAW, Probst P, Rockey DD. Chlamydial antigens colocalize within IncA-laden fibers extending from the inclusion membrane into the host cytosol. Infect Immun 2002; 70:5860-4. [PMID: 12228318 PMCID: PMC128327 DOI: 10.1128/iai.70.10.5860-5864.2002] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
Abstract
Chlamydial IncA localizes to the inclusion membrane and to vesicular fibers extending away from the inclusion. Chlamydial outer membrane components, in the absence of developmental forms, are found within these fibers. This colocalization may explain how chlamydial developmental form antigens are localized outside of the inclusion within infected cells.
Collapse
|
152
|
Piek JJ, Boersma E, Voskuil M, di Mario C, Schroeder E, Vrints C, Probst P, de Bruyne B, Hanet C, Fleck E, Haude M, Verna E, Voudris V, Geschwind H, Emanuelsson H, Mühlberger V, Peels HO, Serruys PW. The immediate and long-term effect of optimal balloon angioplasty on the absolute coronary blood flow velocity reserve. A subanalysis of the DEBATE study. Doppler Endpoints Balloon Angioplasty Trial Europe. Eur Heart J 2001; 22:1725-32. [PMID: 11511122 DOI: 10.1053/euhj.2000.2587] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND There are limited data regarding the immediate and long-term effect of balloon angioplasty on the coronary flow reserve evaluated in a multicentre setting. METHODS AND RESULTS A total of 86 patients with one-vessel disease and normal left ventricular function were analysed before and after optimal balloon angioplasty (diameter stenosis <35%) and at 6-month follow-up. Coronary flow reserve was assessed with a Doppler guide wire. A low coronary flow reserve (<or=2.5) after PTCA, due to an increased baseline blood flow velocity, was encountered in 42 of the 86 patients (49%). Recurrence of angina and target lesion revascularization were more frequent in these patients than in patients with a coronary flow reserve >2.5 (46% vs 23% and 36% vs 16%, respectively; P<0.05) due to a trend towards restenosis (29% vs 16%; P=0.15) or a low coronary flow reserve at follow-up due to persistent elevated baseline blood flow velocity. Patients without restenosis showed a decrease or increase of coronary flow reserve during follow-up, determined by alterations of hyperaemic blood flow velocity. CONCLUSIONS Patients with an impaired coronary flow reserve directly after optimal balloon angioplasty showed a higher target lesion revascularization rate compared to patients with a coronary flow reserve >2.5. This patient group consists of patients prone to develop restenosis, while other patients are characterized by a persistently low coronary flow reserve, probably secondary to disturbed autoregulation and/or diffuse mild coronary atherosclerosis. Coronary flow reserve alterations in patients without restenosis were related to changes in hyperaemic blood flow velocity, suggesting that this phenomenon relates to epicardial remodelling.
Collapse
|
153
|
Foley DP, Pieper M, Wijns W, Suryapranata H, Grollier G, Legrand V, de Scheerder I, Hanet C, Puel J, Mudra H, Bonnier HJ, Colombo A, Thomas M, Probst P, Morice M, Kleijne J, Serruys PW. The influence of stent length on clinical and angiographic outcome in patients undergoing elective stenting for native coronary artery lesions; final results of the Magic 5L Study. Eur Heart J 2001; 22:1585-93. [PMID: 11492988 DOI: 10.1053/euhj.2001.2752] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
AIMS To prospectively evaluate the influence of stent length on 6 month clinical and angiographic outcome, in patients with native coronary lesions up to 45 mm in length, undergoing elective Magic Wallstent implantation. METHODS AND RESULTS On the basis of pre-procedural angiography, 276 patients (aged 61.3+/-10.2 years; 78.6% male; 41.7% unstable angina) with a total of 302 lesions were prospectively assigned to one of five different length categories of Magic Wallstent. Angiography in multiple matched projections before and after implantation and at 6 months follow-up was analysed at the core laboratory. Primary end-points for the efficacy analysis were cumulative incidence of major adverse cardiac events and quantitative coronary angiography analysis 6 months after stent implantation. Magic Wallstent implantation was successful in 301 of 302 lesions and in 98.6% a residual stenosis <20% by online quantitative coronary angiography was achieved. At 30 days, 6.2% (1.8% subacute occlusion) of patients had experienced major adverse cardiac events, 27.5% at 6 months and 30.4% at 9 months. Angiographic restenosis occurred in 37%. Restenosis rates for the mini, extra-short, short, medium and long Wallstent groups were 25.9%, 25%, 22.6%, 36.2% and 67.5%, respectively. Multivariate analysis revealed stent length to be independently associated with greater angiographic restenosis and major adverse cardiac events. CONCLUSIONS While shorter Magic Wallstents provided late outcomes comparable with short balloon-expandable stents, excessive restenosis with longer Wallstents should obviate their use in elective percutaneous intervention. Long coronary lesions provide a challenging substrate for emerging antirestenosis therapies, such as stent coatings and brachytherapy.
Collapse
|
154
|
Haude M, Baumgart D, Verna E, Piek JJ, Vrints C, Probst P, Erbel R. Intracoronary Doppler- and quantitative coronary angiography-derived predictors of major adverse cardiac events after stent implantation. Circulation 2001; 103:1212-7. [PMID: 11238263 DOI: 10.1161/01.cir.103.9.1212] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Distal coronary flow velocity reserve (CVR) is significantly improved after a successful balloon angioplasty (PTCA). Furthermore, a postinterventional CVR >2.5 and a percent diameter stenosis (%DS) </=35% are predictive for a low incidence of major adverse cardiac events (MACE) at 6 months of 16%. Similar results are lacking for coronary stenting. METHODS AND RESULTS In 150 patients, baseline and hyperemic coronary flow velocities were recorded with a Doppler guidewire distal to the target lesion and in an unobstructed reference artery before and after PTCA, after stenting, and at 6 months. Distal CVR and relative CVR (CVR(rel)) were calculated. Logistic regression and receiver operating characteristic analyses were applied to determine prognostic cutoff values of CVR, CVR(rel), %DS, and minimal lumen diameter separately and in combination to predict MACE at 6 months. After stenting, CVR (2.96+/-0.87 versus 2.40+/-0.7; P:=0.001), CVR(rel) (1.02+/-0.24 versus 0.81+/-0.24; P:=0.001), and minimal lumen diameter (2.98+/-0.56 versus 2.11+/-0.74 mm; P:=0.001) were significantly higher than after PTCA. Thirty-three patients developed MACE. A postinterventional CVR(rel)>0.88 was the best single predictor of MACE, with an incidence of 6.8%, whereas the combination of a CVR(rel)>0.88 and a %DS </=11.2% predicted an incidence of MACE of 1.5%. CONCLUSIONS Measurement of CVR(rel) and %DS after stent implantation are best suitable to predict MACE at 6 months.
Collapse
|
155
|
Fling SP, Sutherland RA, Steele LN, Hess B, D'Orazio SE, Maisonneuve J, Lampe MF, Probst P, Starnbach MN. CD8+ T cells recognize an inclusion membrane-associated protein from the vacuolar pathogen Chlamydia trachomatis. Proc Natl Acad Sci U S A 2001; 98:1160-5. [PMID: 11158611 PMCID: PMC14725 DOI: 10.1073/pnas.98.3.1160] [Citation(s) in RCA: 105] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
During infection with Chlamydia trachomatis, CD8(+) T cells are primed, even though the bacteria remain confined to a host cell vacuole throughout their developmental cycle. Because CD8(+) T cells recognize antigens processed from cytosolic proteins, the Chlamydia antigens recognized by these CD8(+) T cells very likely have access to the host cell cytoplasm during infection. The identity of these C. trachomatis proteins has remained elusive, even though their localization suggests they may play important roles in the biology of the organism. Here we use a retroviral expression system to identify Cap1, a 31-kDa protein from C. trachomatis recognized by protective CD8(+) T cells. Cap1 contains no strong homology to any known protein. Immunofluorescence microscopy by using Cap1-specific antibody demonstrates that this protein is localized to the vacuolar membrane. Cap1 is virtually identical among the human C. trachomatis serovars, suggesting that a vaccine incorporating Cap1 might enable the vaccine to protect against all C. trachomatis serovars. The identification of proteins such as Cap1 that associate with the inclusion membrane will be required to fully understand the interaction of C. trachomatis with its host cell.
Collapse
|
156
|
Probst P, Stromberg E, Ghalib HW, Mozel M, Badaro R, Reed SG, Webb JR. Identification and characterization of T cell-stimulating antigens from Leishmania by CD4 T cell expression cloning. JOURNAL OF IMMUNOLOGY (BALTIMORE, MD. : 1950) 2001; 166:498-505. [PMID: 11123329 DOI: 10.4049/jimmunol.166.1.498] [Citation(s) in RCA: 63] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Persistent immunity against Leishmania: infections in humans is mediated predominantly by CD4(+) T cells of the Th1 phenotype. Herein we report the expression cloning of eight Leishmania: Ags using parasite-specific T cell lines derived from an immune donor. The Ags identified by this technique include the flagellar proteins alpha- and beta-tubulin, histone H2b, ribosomal protein S4, malate dehydrogenase, and elongation factor 2, as well as two novel parasite proteins. None of these proteins have been previously reported as T cell-stimulating Ags from Leishmania: beta-tubulin-specific T cell clones generated against Leishmania: major amastigotes responded to Leishmania:-infected macrophages and dendritic cells. IFN-gamma enzyme-linked immunospot analysis demonstrated the presence of T cells specific for several of these Ags in PBMC from self-healing cutaneous leishmaniasis patients infected with either Leishmania: tropica or L. major. The responses elicited by Leishmania: histone H2b were particularly striking in terms of frequency of histone-specific T cells in PBMC (1 T cell of 6000 PBMC) as well as the percentage of responding donors (86%, 6 of 7). Ags identified by T cells from immune donors might constitute potential vaccine candidates for leishmaniasis.
Collapse
|
157
|
Serruys PW, de Bruyne B, Carlier S, Sousa JE, Piek J, Muramatsu T, Vrints C, Probst P, Seabra-Gomes R, Simpson I, Voudris V, Gurné O, Pijls N, Belardi J, van Es GA, Boersma E, Morel MA, van Hout B. Randomized comparison of primary stenting and provisional balloon angioplasty guided by flow velocity measurement. Doppler Endpoints Balloon Angioplasty Trial Europe (DEBATE) II Study Group. Circulation 2000; 102:2930-7. [PMID: 11113042 DOI: 10.1161/01.cir.102.24.2930] [Citation(s) in RCA: 71] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Coronary stenting improves outcomes compared with balloon angioplasty, but it is costly and may have other disadvantages. Limiting stent use to patients with a suboptimal result after angioplasty (provisional angioplasty) may be as effective and less expensive. METHODS AND RESULTS To analyze the cost-effectiveness of provisional angioplasty, patients scheduled for single-vessel angioplasty were first randomized to receive primary stenting (97 patients) or balloon angioplasty guided by Doppler flow velocity and angiography (523 patients). Patients in the latter group were further randomized after optimization to either additional stenting or termination of the procedure to further investigate what is "optimal." An optimal result was defined as a flow reserve >2.5 and a diameter stenosis <36%. Bailout stenting was needed in 129 patients (25%) who were randomized to balloon angioplasty, and an optimal result was obtained in 184 of the 523 patients (35%). There was no significant difference in event-free survival at 1 year between primary stenting (86.6%) and provisional angioplasty (85.6%). Costs after 1 year were significantly higher for provisional angioplasty (EUR 6573 versus EUR 5885; P:=0.014). Results after the second randomization showed that stenting was also more effective after optimal balloon angioplasty (1-year event free survival, 93.5% versus 84.1%; P:=0. 066). CONCLUSIONS After 1 year of follow-up, provisional angioplasty was more expensive and without clinical benefit. The beneficial value of stenting is not limited to patients with a suboptimal result after balloon angioplasty.
Collapse
|
158
|
Laine L, Fennerty MB, Osato M, Sugg J, Suchower L, Probst P, Levine JG. Esomeprazole-based Helicobacter pylori eradication therapy and the effect of antibiotic resistance: results of three US multicenter, double-blind trials. Am J Gastroenterol 2000; 95:3393-8. [PMID: 11151867 DOI: 10.1111/j.1572-0241.2000.03349.x] [Citation(s) in RCA: 98] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
OBJECTIVES To determine the efficacy of once-daily esomeprazole plus antibiotics for eradication of Helicobacter pylori, to assess the effect of antibiotic resistance on eradication rate, and to define the rate of emergent resistance. METHODS Three separate randomized trials were performed in H. pylori-positive patients with a duodenal ulcer or history of documented duodenal ulcer within 5 yrs: 1) esomeprazole (40 mg once daily), amoxicillin (1 g b.i.d.), and clarithromycin (500 mg b.i.d.; this combination will be referred to as EAC) versus esomeprazole (40 mg once daily) plus clarithromycin (500 mg twice daily; this combination will be referred to as EC); 2) EAC versus esomeprazole (40 mg once daily; E); and 3) EC versus E. Therapy was given for 10 days. Endoscopy and biopsies for CLOtest, histology, and culture with susceptibility testing were done at baseline and 4 wk after completion of therapy. RESULTS Per-protocol and intent-to-treat eradication rates, respectively, were as follows. For EAC versus EC in study 1 (N = 448), 84 versus 55% and 77 versus 52% (p < 0.001); for EAC versus E in study 2 (N = 98), 85 versus 5% and 78 versus 4% (p < 0.001); for EC versus E in study 3 (N = 66), 50% versus 0 and 46% versus 0 (p < 0.05). The 15% of patients in the combined studies with baseline clarithromycin resistance had significantly lower rates of eradication than those with susceptible strains (EAC: 45 vs. 89%; EC: 13 vs. 61%). Emergent resistance was less common after treatment with EAC [2/6 (33%)] than with EC (23/27 [85%]). CONCLUSIONS Ten-day triple therapy with once-daily esomeprazole plus twice-daily amoxicillin and clarithromycin achieves an eradication rate virtually identical to that of the twice-daily proton pump inhibitor-based triple therapies. Baseline clarithromycin resistance, present in 15% of patients, predicts a markedly decreased rate. Use of an amoxicillin-containing regimen may decrease emergence of clarithromycin resistance.
Collapse
|
159
|
Porenta G, Binder T, Moertl D, Zehetgruber M, Graf S, Maurer G, Probst P. Functional assessment of coronary arteries by poststenotic intravascular Doppler ultrasound. J Vasc Res 2000; 37:594-602. [PMID: 11146414 DOI: 10.1159/000054093] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
This study sought to delineate the impact of the rate pressure product on intraluminal Doppler velocity measurements and to determine the relation between poststenotic vasodilator reserve and percent luminal obstruction in coronary vessels. Twenty patients with single-vessel coronary disease were studied prior to coronary angioplasty and at follow-up 6 months later. Intracoronary velocity reserve after administration of adenosine was measured distal to the stenosis with a Doppler-tipped guide wire and was compared to quantitative coronary angiography and adenosine myocardial perfusion scintigraphy. The rate pressure product was confirmed as significant covariate (ANCOVA, p < 0.005) of intracoronary Doppler reserve. When normalized to rate pressure product, poststenotic Doppler velocity reserve in stenosed arteries was significantly lower than in patent arteries as classified by quantitative coronary angiography (1.7 +/- 0.6 vs. 2.9 +/- 0.5, p < 0.001) and perfusion scintigraphy (1.5 +/- 0.4 vs. 2.8 +/- 0.5, p < 0.001). Normalized Doppler velocity reserve showed a nonlinear but highly significant relation to percent area stenosis [y = 3.0.(1 - exp[0.081 (x - 100)]), p < 0.001]. When normalized Doppler velocity reserve was less than 2.0, coronary disease was identified with 95% specificity and 94% sensitivity in comparison to perfusion scintigraphy. Thus, in coronary arteries poststenotic Doppler reserve and percent area stenosis show a significant nonlinear relation. Doppler velocity reserve when normalized to rate pressure product can be used to characterize the hemodynamic impact of coronary obstructions.
Collapse
|
160
|
Gottsauner-Wolf M, Zasmeta G, Hornykewycz S, Nikfardjam M, Stepan E, Wexberg P, Zorn G, Glogar D, Probst P, Maurer G, Huber K. Plasma levels of C-reactive protein after coronary stent implantation. Eur Heart J 2000; 21:1152-8. [PMID: 10924298 DOI: 10.1053/euhj.1999.1987] [Citation(s) in RCA: 91] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
AIMS This study was designed to investigate the role of inflammation on the occurrence of angiographic restenosis 6 months after coronary stent implantation and the influence of different kinds of antithrombotic and antiplatelet strategies on inflammation. METHODS AND RESULTS In an open randomized trial, 40 consecutive patients were treated with aspirin (100 mg. day(-1)) and either ticlopidine (2x250 mg. day(-1)) (n=17), or phenprocoumon (INR 2.0-3.0) and dipyridamole (3x160 mg. day(-1)) (n=23) after successful elective coronary stent implantation. Plasma levels of C-reactive protein were determined one day before stent implantation and serially thereafter twice daily up to 120 h. C-reactive protein plasma levels increased significantly (P<0.0001) after stent implantation. Phenprocoumon and dipyridamole or ticlopidine had no effect on C-reactive protein plasma levels (P=0.51) or the occurrence of angiographic restenosis (P=0.48). C-reactive protein plasma levels were significantly higher in patients with lesion type C compared to types A or B (P=0.035), respectively. C-reactive protein plasma levels were significantly higher and mean shoulder levels occurred 48 h later in patients with restenosis compared to patients without restenosis after 6 months (P=0.038). CONCLUSIONS Elevated C-reactive protein plasma levels still persisting 96 h after stent implantation might reflect a prolonged inflammatory reaction to coronary stent implantation which might causally be involved in pathophysiological mechanisms leading to restenosis.
Collapse
|
161
|
Cremonesi A, Benit E, Carlier M, Colombo A, Piva R, Probst P, Wirtzfeld A, Pico-Bourdonnec C, Corcos T. Multicenter registry to evaluate the efficacy of the NIROYAL stent in de novo or restenotic coronary stenosis. THE JOURNAL OF INVASIVE CARDIOLOGY 2000; 12:225-32. [PMID: 10825762] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/16/2023]
Abstract
The purpose of this registry was to document the safety and efficacy of elective deployment of the NIROYAL stent (Boston Scientific SCIMED, Maple Grove, Minnesota) in coronary arteries. This was a prospective, multi-center international registry. NIROYAL stents (9, 16, 25 and 32 mm-long) were manually crimped onto coronary balloons and deployed in de novo or restenotic lesions in 165 male and female patients with angina pectoris and a reference vessel diameter of 2.0-4.5 mm. Stent deployment was successful in 98.8% of the lesions. Mean percent diameter stenosis decreased from 83.5+/-10.8% to 2.7+/- 6.2% after intervention. The interventional procedure of the treatment site was successful in 97.6% of patients. At six-month clinical follow-up, 88.5% had event-free survival [i.e., did not experience a major adverse cardiac event (MACE)] and 95.2% had no anginal symptoms. Furthermore, 87.3% of the patients were free of target vessel failure (defined as a composite of acute procedural failure, target vessel revascularization, myocardial infarction or death at six months). Only three MACE were observed within the first 30 days after stent implantation. A low left ventricular ejection fraction and the percentage stenosis pre-procedure were identified as statistically significant (p<0.05) predictive factors for MACE. The incidences of MACE and target vessel failure after six months follow-up were lower than that seen in other studies, and target lesion revascularization rates were low.
Collapse
|
162
|
Piek JJ, Boersma E, di Mario C, Schroeder E, Vrints C, Probst P, de Bruyne B, Hanet C, Fleck E, Haude M, Verna E, Voudris V, Geschwind H, Emanuelsson H, Mühlberger V, Peels HO, Serruys PW. Angiographical and Doppler flow-derived parameters for assessment of coronary lesion severity and its relation to the result of exercise electrocardiography. DEBATE study group. Doppler Endpoints Balloon Angioplasty Trial Europe. Eur Heart J 2000; 21:466-74. [PMID: 10681487 DOI: 10.1053/euhj.1999.1871] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
AIMS Evaluation of angiographical and intracoronary Doppler-derived parameters of coronary stenosis severity. METHODS AND RESULTS A total of 225 patients with one-vessel disease were studied before PTCA and at 6 months follow-up. Exercise electrocardiography was performed to document presence (n = 157) or absence (n = 138) of an ST segment shift (> or =0.1 mV). Intracoronary blood flow velocity analysis was performed to determine the proximal/distal flow velocity ratio, the distal diastolic/systolic flow velocity ratio and coronary flow velocity reserve. Receiver operator characteristic curves were calculated to assess the predictive value of these variables compared with the exercise test. The distal coronary flow velocity reserve demonstrated the best linear correlation for both percentage diameter stenosis and minimum lumen diameter (r = 0.67 and r = 0.66; P<0.01), compared to the diastolic/systolic flow velocity ratio (r = 0.19 and r = 0.14; P<0.01) and the proximal/distal flow velocity ratio (r = 0.03 and r = 0.07; not significant). The areas under the curve were 0. 84+/-0.02; 0.82+/-0.03 and 0.83+/-0.03 for diameter stenosis, minimum lumen diameter and coronary flow velocity reserve, respectively. Logistic regression analysis revealed that the percentage diameter stenosis or minimum lumen diameter and coronary flow velocity reserve were independent predictors for the result of stress testing. CONCLUSIONS The distal coronary flow velocity reserve is the best intracoronary Doppler parameter for evaluation of coronary narrowings. Angiographical estimates of coronary lesion severity and distal coronary flow velocity reserve are good and independent predictors for the assessment of functional severity of coronary stenosis, emphasizing the complementary role of these parameters for clinical decision making.
Collapse
|
163
|
Borer H, Klar J, Probst P. [Liver metastasis?]. SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT 1999; 129:851. [PMID: 10413824] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 02/13/2023]
|
164
|
Porenta G, Schima H, Pentaris A, Tsangaris S, Moertl D, Probst P, Maurer G, Baumgartner H. Assessment of coronary stenoses by Doppler wires: a validation study using in vitro modeling and computer simulations. ULTRASOUND IN MEDICINE & BIOLOGY 1999; 25:793-801. [PMID: 10414896 DOI: 10.1016/s0301-5629(99)00033-2] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
The present study evaluates the use of intracoronary velocity measurements by Doppler guidewires for assessing coronary obstructions. In vitro experiments were performed in a flow model using acrylic phantoms of coronary stenoses with different configurations (stenosis area: 56%, 75% and 89%; stenosis length: 1 and 5 mm; stenosis border: tapering or abrupt). Nonpulsatile laminar flow conditions of a test fluid were established at flow rates ranging from 0.5 to 2.0 mL/s to simulate baseline flow and flow after vasodilation. Peak Doppler velocity was measured proximal to, within and distal to the model stenoses. Computer simulations were employed to calculate radial flow profiles with and without a Doppler wire aligned with the vessel center. In 84 in vitro flow experiments, peak Doppler velocity correlated well with the average flow velocity as calculated from the actual flow rate and the vessel's cross-sectional area proximal to (r = 0.98, SEE = 1.4, p < 0.001) and within (r = 0.97, SEE = 16.4, p < 0.001) the stenosis. However, the ratio of calculated average velocity to Doppler-measured peak velocity was significantly different from 0.5, the expected value for a parabolic flow profile (0.76+/-0.08, 0.81+/-0.14; p < 0.001). Acceptable accuracy was found for the Doppler estimation of stenosis severity using the continuity equation (error: 0.9+/-1.2% and -4.6+/-3.5% for stenosis with a length of 5 mm and 1 mm, respectively). Doppler velocity reserve significantly underestimated the true flow reserve for the 56% and 75% stenoses (p < 0.01). Computer simulations demonstrated significant alterations of flow profiles by the wire, which explained the observed underestimation of the true flow reserve by the Doppler velocity reserve. Thus, Doppler guidewire measurements of intracoronary flow velocities are useful to assess the severity of coronary stenoses. However, the in vitro results and computer simulations indicate that guidewires alter the flow profile, so that Doppler velocity reserve may underestimate the true flow reserve.
Collapse
|
165
|
Gottsauner-Wolf M, Sochor H, Hornykewycz S, Beckmann R, Lang I, Probst P, Binder BR, Huber K. Predictive value of PAI-1 plasma activity and thallium perfusion imaging for restenosis after percutaneous transluminal angioplasty in clinically asymptomatic patients. Thromb Haemost 1999; 81:522-6. [PMID: 10235432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
Abstract
BACKGROUND The main long-term complication of percutaneous transluminal coronary angioplasty (PTCA) is restenosis that occurs in 30-50 percent of all primary successful cases. The purpose of this study was to evaluate the predictive value of changes in plasminogen activator inhibitor-1 (PAI-1) activity and of thallium dipyridamole perfusion imaging performed 3 months after successful angioplasty. All patients were asymptomatic at evaluation. The results of these two noninvasive tests were compared with the angiographic outcome after 6 months. METHOD AND PATIENTS Twenty-five patients were included in this prospective study. All patients had single vessel disease, successful angioplasty and were free of clinical symptoms 3 months after angioplasty that would suggest late restenosis. In 12/25 patients (48%) angiographic restenosis (percent diameter stenosis >50%) was determined by follow-up angiography 6 months after angioplasty. PAI-1 plasma activity was determined by a functional titration assay and increase or decrease of PAI-1 plasma activity was evaluated between values obtained before and 3 months after angioplasty. In 7/25 (28%) patients PAI-1 plasma activity increased to more than 90% of pre-angioplasty values. This increase correlated with angiographic restenosis evaluated 6 months after angioplasty (sensitivity 42%, specificity 85%, positive predictive value 71%, and negative predictive value 61%). T1-201-perfusion imaging was performed 3 months after angioplasty. This test was indicative for subsequent restenosis in 5/25 patients (sensitivity 33%, specificity 100%, positive predictive value 62%, and negative predictive value 100%). In 10/25 (40%) patients at least one of the two non-invasive tests performed 3 months after angioplasty predicted angiographic restenosis at 6 months: the combined use of PAI-1 and T1-201-perfusion imaging resulted in increased sensitivity (67%) and high specificity (85%). CONCLUSION The results of this study indicate that an increase of PAI-1 plasma activity may improve the predictive value for restenosis of T1-201-scintigraphy performed 3 months after angioplasty even in asymptomatic patients.
Collapse
|
166
|
Probst P. "Mchape" '95, or, the sudden fame of Billy Goodson Chisupe: healing, social memory and the enigma of the public sphere in post-Banda Malawi. AFRICA : JOURNAL OF THE INTERNATIONAL INSTITUTE OF AFRICAN LANGUAGES AND CULTURES 1999; 69:108-138. [PMID: 19149021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
|
167
|
Erbel R, Haude M, Höpp HW, Franzen D, Rupprecht HJ, Heublein B, Fischer K, de Jaegere P, Serruys P, Rutsch W, Probst P. Coronary-artery stenting compared with balloon angioplasty for restenosis after initial balloon angioplasty. Restenosis Stent Study Group. N Engl J Med 1998; 339:1672-8. [PMID: 9834304 DOI: 10.1056/nejm199812033392304] [Citation(s) in RCA: 213] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
BACKGROUND Intracoronary stenting reduces the rate of restenosis after angioplasty in patients with new coronary lesions. We conducted a prospective, randomized, multicenter study to determine whether intracoronary stenting, as compared with standard balloon angioplasty, reduces the recurrence of luminal narrowing in restenotic lesions. METHODS A total of 383 patients who had undergone at least one balloon angioplasty and who had clinical and angiographic evidence of restenosis after the procedure were randomly assigned to undergo standard balloon angioplasty (192 patients) or intracoronary stenting with a Palmaz-Schatz stent (191 patients). The primary end point was angiographic evidence of restenosis (defined as stenosis of more than 50 percent of the luminal diameter) at six months. The secondary end points were death, Q-wave myocardial infarction, bypass surgery, and revascularization of the target vessel. RESULTS The rate of restenosis was significantly higher in the angioplasty group than in the stent group (32 percent as compared with 18 percent, P= 0.03). Revascularization of the target vessel at six months was required in 27 percent of the angioplasty group but in only 10 percent of the stent group (P=0.001). This difference resulted from a smaller mean (+/-SD) minimal luminal diameter in the angioplasty group (1.85+/-0.56 mm) than in the stent group (2.04+/-0.66 mm), with a mean difference of 0.19 mm (P=0.01) at follow-up. Subacute thrombosis occurred in 0.6 percent of the angioplasty group and in 3.9 percent of the stent group. The rate of event-free survival at 250 days was 72 percent in the angioplasty group and 84 percent in the stent group (P=0.04). CONCLUSIONS Elective coronary stenting was effective in the treatment of restenosis after balloon angioplasty. Stenting resulted in a lower rate of recurrent stenosis despite a higher incidence of subacute thrombosis.
Collapse
|
168
|
Krech M, Probst P. [Social intelligence deficits in autistic children and adolescents--subjective theories of psychosocial health care professionals]. Prax Kinderpsychol Kinderpsychiatr 1998; 47:574-88. [PMID: 9847638] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
The paper is concerned with personal theories of health care professionals about deficiencies in social intelligence of autistic persons. In the component-model of social intelligence means the ability of individuals or groups, to interact with each other in social situations. This contains social perception, social behavior as well as social conceptions and refers to emotional, cognitive and normative aspects. 33 interviewees, working as psychologists or teachers in kindergartens, schools or therapy institutions, are questioned by a half-standardized single interview concerning their beliefs about nonverbal social abilities, social perspective taking, and construction of a theory of mind in autistic persons. The major finding is: The impairments can be found in all aspects of social intelligence. Especially emotional handicaps, which are quoted by more than 80% of the interviewees, and low cognitive preconditions of mastering social stimuli, which are quoted by nearly all interviewees, are relevant. The subjective theories of the interviewees are in accordance to the models of parents as well as the models of the leading experts. The professional relationship to autistic persons and the practical experiences of the health care professionals lead to their specific personal theories of deficiencies in social intelligence of autistic people with wide consequences in respect to the professional contact with the autistic children and young adults.
Collapse
|
169
|
Reed S, Webb J, Campos-Neto A, Seder R, Gurunathan S, Skeiky Y, Probst P, Badaro R. Development of a recombinant vaccine for human leishmaniosis. Parasitol Int 1998. [DOI: 10.1016/s1383-5769(98)80046-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
170
|
Granfors K, Merilahti-Palo R, Luukkainen R, Möttönen T, Lahesmaa R, Probst P, Märker-Hermann E, Toivanen P. Persistence of Yersinia antigens in peripheral blood cells from patients with Yersinia enterocolitica O:3 infection with or without reactive arthritis. ARTHRITIS AND RHEUMATISM 1998; 41:855-62. [PMID: 9588737 DOI: 10.1002/1529-0131(199805)41:5<855::aid-art12>3.0.co;2-j] [Citation(s) in RCA: 91] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVE To assess the persistence of bacterial antigens in peripheral blood cells from patients with Yersinia enterocolitica O:3-triggered reactive arthritis (ReA). METHODS Peripheral blood samples were obtained from 20 patients with Y. enterocolitica O:3 infection (11 with ReA and 9 without). These samples were studied by immunochemical techniques for the presence of Yersinia antigens at the beginning of infection and up to 4 years thereafter. Synovial fluid samples from 6 of the 11 ReA patients were also studied. RESULTS The Yersinia antigens lipopolysaccharide and heat-shock protein (HSP) were detected in peripheral blood mononuclear cells and polymorphonuclear phagocytes from all patients studied at the early phase of the disease. They were also found in the synovial fluid cells of patients with Yersinia-triggered ReA. At 4 years after the onset of infection, these bacterial antigens were still detected in the peripheral blood cells of most of the ReA patients studied. CONCLUSION This study has, for the first time, directly demonstrated that bacterial antigens persist for a long time in patients who develop ReA after Y. enterocolitica O:3 infection. The finding of bacterial HSP in synovial fluid cells could provide a link to the pathogenesis of ReA, since T cell responses of synovial cells have been shown to be directed against that structure. A close similarity between the bacterial and host HSP might contribute to the development of the relatively common, chronic form of this complication.
Collapse
|
171
|
Haude M, Baumgart D, Vema E, Piek J, Vrints C, Probst P, Serruys P, Erbel R. Doppler flow velocity reserve after coronary stent implantation: results of the DEBATE stent ancillary trial. J Am Coll Cardiol 1998. [DOI: 10.1016/s0735-1097(98)80034-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
172
|
Serruys PW, di Mario C, Piek J, Schroeder E, Vrints C, Probst P, de Bruyne B, Hanet C, Fleck E, Haude M, Verna E, Voudris V, Geschwind H, Emanuelsson H, Mühlberger V, Danzi G, Peels HO, Ford AJ, Boersma E. Prognostic value of intracoronary flow velocity and diameter stenosis in assessing the short- and long-term outcomes of coronary balloon angioplasty: the DEBATE Study (Doppler Endpoints Balloon Angioplasty Trial Europe). Circulation 1997; 96:3369-77. [PMID: 9396429 DOI: 10.1161/01.cir.96.10.3369] [Citation(s) in RCA: 182] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
BACKGROUND The aim of this prospective, multicenter study was the identification of Doppler flow velocity measurements predictive of clinical outcome of patients undergoing single-vessel balloon angioplasty with no previous Q-wave myocardial infarction. METHODS AND RESULTS In 297 patients, a Doppler guidewire was used to measure basal and maximal hyperemic flow velocities proximal and distal to the stenosis before and after angioplasty. In 225 patients with an angiographically successful percutaneous transluminal coronary angioplasty (PTCA), postprocedural distal coronary flow reserve (CFR) and percent diameter stenosis (DS%) were correlated with symptoms and/or ischemia at 1 and 6 months, with the need for target lesion revascularization, and with angiographic restenosis (defined as DS > or = 50% at follow-up). Logistic regression and receiver operator characteristic curve analyses were applied to determine the prognostic cutoff value of CFR and DS separately and in combination. Optimal cutoff criteria for predictors of these clinical events were DS, 35%; CFR, 2.5. A distal CFR after angioplasty > 2.5 with a residual DS < or = 35% identified lesions with a low incidence of recurrence of symptoms at 1 month (10% versus 19%, P=.149) and at 6 months (23% versus 47%, P=.005), a low need for reintervention (16% versus 34%, P=.024), and a low restenosis rate (16% versus 41%, P=.002) compared with patients who did not meet these criteria. CONCLUSIONS Measurements of distal CFR after PTCA, in combination with DS%, have a predictive value, albeit modest for the short- and long-term outcomes after PTCA, and thus may be used to identify patients who will or will not benefit from additional therapy such as stent implantation.
Collapse
|
173
|
Zehetgruber M, Porenta G, Mundigler G, Mörtl D, Binder T, Christ G, Probst P, Baumgartner H, Maurer G, Siostrzonek P. Transesophageal versus intracoronary Doppler measurements for calculation of coronary flow reserve. Cardiovasc Res 1997; 36:21-7. [PMID: 9415268 DOI: 10.1016/s0008-6363(97)00166-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/05/2023] Open
Abstract
OBJECTIVE The present study was performed to compare coronary flow reserve by transesophageal Doppler echocardiography and intracoronary Doppler flow wire measurements in patients with LAD disease. METHODS 17 patients with various degree of LAD stenosis were studied. Intracoronary LAD Doppler measurements were performed at baseline and after intracoronary injection of 18 micrograms adenosine. Transesophageal coronary sinus and LAD Doppler measurements were performed at baseline and after intravenous dipyridamole (0.6 mg/kg/5 min). Coronary flow reserve was calculated as the ratio of hyperemic to baseline average peak velocities. RESULTS Coronary flow reserve was 2.44 +/- 0.62 and 2.19 +/- 0.76 for proximal and distal intracoronary measurements and was 2.25 +/- 0.64 and 1.74 +/- 0.63 for transesophageal LAD- and coronary sinus measurements. Proximal intracoronary flow reserve significantly correlated with transesophageal coronary sinus (r = 0.73, p < or = 0.001) and LAD (r = 0.70, p < or = 0.005) measurements, whereas distal intracoronary flow reserve only correlated with transesophageal coronary sinus flow reserve (r = 0.56, p < or = 0.02). Receiver operating characteristic curve analysis demonstrated similar diagnostic accuracy of all applied techniques for detection of a significant LAD stenosis. CONCLUSIONS Coronary flow reserve by both transesophageal techniques correlated with intracoronary Doppler flow wire measurements, however considerable discrepancies may occur in the individual patient.
Collapse
|
174
|
Probst P, Skeiky YA, Steeves M, Gervassi A, Grabstein KH, Reed SG. A Leishmania protein that modulates interleukin (IL)-12, IL-10 and tumor necrosis factor-alpha production and expression of B7-1 in human monocyte-derived antigen-presenting cells. Eur J Immunol 1997; 27:2634-42. [PMID: 9368620 DOI: 10.1002/eji.1830271024] [Citation(s) in RCA: 76] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
LeIF, a gene homologue of the eukaryotic initiation factor 4A was first described as a leishmanial antigen that induced a Th1-type T cell response in peripheral blood mononuclear cells (PBMC) from leishmaniasis patients. Moreover, the interferon (IFN)-gamma production by PBMC was found to be interleukin (IL)-12 dependent. Herein, we characterize the effects of LeIF on cytokine production and expression of surface molecules by normal human monocytes as well as by monocyte-derived macrophages and dendritic cells (MoDC). LeIF was a strong inducer of IL-12 and, to a lesser extent, of IL-10 and tumor necrosis factor (TNF)-alpha in macrophages and MoDC. IL-12 production did not require CD40 triggering, confirming that the ability of LeIF to induce IL-12 was not mediated through an effect on T cells. However, addition of soluble CD40 ligand (L) synergistically augmented IL-12 production in macrophages and MoDC. The cytokine-inducing activity of LeIF is located in the N-terminal portion of the molecule and was both proteinase K sensitive and polymyxin B resistant. LeIF, lipopolysaccharide and fixed Staphylococcus aureus all induced comparable amounts of IL-12, validating the potent cytokine-inducing effects of LeIF. Moreover, of these stimuli, LeIF had the highest IL-12/IL-10 and IL-12/TNF-alpha ratio demonstrating the preference of LeIF for IL-12 induction. Studies investigating the expression of surface molecules showed that LeIF up-regulated B7-1 and CD54 (ICAM-1) on macrophages and MoDC. To our knowledge this is the first report describing IL-12 production, up-regulation of co-stimulatory and intercellular adhesion molecules by monocytic antigen-presenting cells in response to a protein from a pathogenic microorganism. These immunomodulatory characteristics of LeIF might be excellent properties for a Th1-type adjuvant.
Collapse
|
175
|
Gwechenberger M, Katzenschlager R, Heinz G, Gottsauner-Wolf M, Probst P. Use of a collagen plug versus manual compression for sealing arterial puncture site after cardiac catheterization. Angiology 1997; 48:121-6. [PMID: 9040266 DOI: 10.1177/000331979704800204] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
The aim of the study was to investigate (1) the safety and efficacy of the application of a collagen plug (Vasoseal) at arterial puncture sites, (2) the hemostasis time, and (3) the comfort for the patient of a collagen plug (Vasoseal) when compared with manual compression. Sixty-two patients were randomized either for application of a collagen plug (Vasoseal, group A, n = 33) or manual compression (group B, n = 29) after cardiac catheterization. All patients were evaluated for subjective pain score ranging from 1 to 5 (1 = no pain up to 5 = very strong pain). In addition the authors measured the time until hemostasis could be achieved. The patients were evaluated by duplex sonography for complications at days 1 and 7 after the procedure. The pain score demonstrated a significantly lower score in group A when compared with group B (P = 0.01). The mean time for hemostasis was significantly lower in group A (mean 9.6 minutes) when compared with group B (mean 23.6 minutes) (P = 0.0001). Regarding the complication rate there was no significant difference between the groups (group A vs group B, P = 0.82). The authors conclude that the application of a collagen plug at the arterial puncture site is a safe and time-saving method. In addition it is less painful and therefore better tolerated than manual compression.
Collapse
|