Duan Z, Huang K, Luo Z, Ma K, Wang G, Hu X, Zhang J, Luo X, Huang Y, Liu G, Ding X, Xiao P, Yuan J. Portable boom-type ultrahigh-resolution OCT with an integrated imaging probe for supine position retinal imaging. BIOMEDICAL OPTICS EXPRESS 2022; 13:3295-3310. [PMID: 35781965 PMCID: PMC9208590 DOI: 10.1364/boe.456435] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Revised: 04/26/2022] [Accepted: 04/29/2022] [Indexed: 06/15/2023]
Abstract
To expand the clinical applications and improve the ease of use of ultrahigh-resolution optical coherence tomography (UHR-OCT), we developed a portable boom-type ophthalmic UHR-OCT operating in supine position that can be used for pediatric subjects, bedridden patients and perioperative conditions. By integrating the OCT sample arm probe with real-time iris display and automatic focusing electric lens for easy alignment, coupling the probe on a self-locking multi-directional manipulator to reduce motion artifacts and operator fatigue, and installing the OCT module on a moveable cart for system mobility, our customized portable boom-type UHR-OCT enables non-contact, high-resolution and high-stability retinal examinations to be performed on subjects in supine position. The spectral-domain UHR-OCT operates at a wavelength of 845 nm with 130 nm FWHM (full width at half maximum) bandwidth, achieving an axial resolution of ≈2.3µm in tissue with an A-line acquisition rate up to 128 kHz. A high-definition two-dimensional (2D) raster protocol was used for high-quality cross-sectional imaging while a cube volume three-dimensional (3D) scan was used for three-dimensional imaging and en-face reconstruction, resolving major layer structures of the retina. The feasibility of the system was demonstrated by performing supine position 2D/3D retinal imaging on healthy human subjects, sedated infants, and non-sedated awake neonates.
Collapse
Affiliation(s)
- Zhengyu Duan
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou 510060, China
- School of Biomedical Engineering, Sun Yat-sen University, Guangzhou 510006, China
- the authors contributed equally to this paper
| | - Kai Huang
- School of Computer Science and Engineering, Sun Yat-sen University, Guangzhou 510006, China
| | - Zhongzhou Luo
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou 510060, China
| | - Ke Ma
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou 510060, China
| | - Gengyuan Wang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou 510060, China
| | - Xiaodong Hu
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou 510060, China
| | - Jinze Zhang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou 510060, China
| | - Xiaoling Luo
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou 510060, China
| | - Yuancong Huang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou 510060, China
| | - Gangjun Liu
- Shenzhen Bay Laboratory, Shenzhen 518132, China
| | - Xiaoyan Ding
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou 510060, China
- the authors contributed equally to this paper
| | - Peng Xiao
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou 510060, China
| | - Jin Yuan
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou 510060, China
| |
Collapse
|
152
|
Recent Advances in Intraoperative Lumpectomy Margin Assessment for Breast Cancer. CURRENT BREAST CANCER REPORTS 2022. [DOI: 10.1007/s12609-022-00451-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
153
|
Choi WJ, Li Y, Wang RK, Kim JK. Automated counting of cerebral penetrating vessels using optical coherence tomography images of a mouse brain in vivo. Med Phys 2022; 49:5225-5235. [PMID: 35616390 DOI: 10.1002/mp.15775] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2022] [Revised: 05/17/2022] [Accepted: 05/17/2022] [Indexed: 11/08/2022] Open
Abstract
RATIONALE AND OBJECTIVES Penetrating blood vessels emanating from cortical surface vasculature and lying deep in the cortex are essential vascular conduits for the shuttling of blood from superficial pial vessels to the capillary beds in parenchyma for the nourishment of neuronal brain tissues. Locating and counting the penetrating vessels is beneficial for the quantification of a course of ischemia in blood occlusive events such as stroke. This paper seeks to demonstrate and validate a method for automated penetrating vessel counting that uses optical coherence tomography (OCT). MATERIALS AND METHODS This paper proposes an OCT method that effectively identifies and grades the cortical penetrating vessels in perfusion. The key to the proposed method is the harnessing of vascular features found in the penetrating vessels, which are distinctive from those of other vessels. In particular, with an increase in the light attenuation and flow turbulence, the contrast in the mean projection of the OCT datacube decreases, whereas that in the maximum projection of the Doppler frequency variance datacube increases. By multiplying the inversion of the former with the latter, its binary thresholding is sufficient to highlight the penetrating vessels and allows for their counting over the projection image. RESULTS A computational method that leverages the decrease in mean OCT projection intensity and the increase in Doppler frequency variance at the penetrating vessel is developed. It successfully identifies and counts penetrating vessels with a high accuracy of over 87%. The penetrating vessel density is observed to be significantly reduced in the mouse model of focal ischemic stroke. CONCLUSION The OCT analysis is effective for counting penetrating blood vessels in mice brains and may be applied to the rapid diagnosis and treatment of stroke in stroke models of small animals. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Woo June Choi
- School of Electrical and Electronics Engineering, Chung-Ang University, 84 Heukseok-ro, Dongjak-gu, Seoul, 06974, Korea
| | - Yuandong Li
- Department of Bioengineering, University of Washington, Seattle, WA, 98195, USA
| | - Ruikang K Wang
- Department of Bioengineering, University of Washington, Seattle, WA, 98195, USA
| | - Jun Ki Kim
- Department of Convergence Medicine, University of Ulsan College of Medicine, 88, Olympic-ro 43-gil, Seoul, 05505, Korea.,Asan Institute for Life Science, Asan Medical Center, 88, Olympic-ro 43-gil, Songpa-gu, Seoul, 05505, Korea
| |
Collapse
|
154
|
Lentsch G, Baugh EG, Lee B, Aszterbaum M, Zachary CB, Kelly KM, Balu M. Research Techniques Made Simple: Emerging Imaging Technologies for Noninvasive Optical Biopsy of Human Skin. J Invest Dermatol 2022; 142:1243-1252.e1. [PMID: 35461534 PMCID: PMC9802025 DOI: 10.1016/j.jid.2022.01.016] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2021] [Revised: 01/07/2022] [Accepted: 01/18/2022] [Indexed: 01/03/2023]
Abstract
Over the past few years, high-resolution optical imaging technologies such as optical coherence tomography (OCT), reflectance confocal microscopy (RCM), and multiphoton microscopy (MPM) have advanced significantly as new methodologies for clinical research and for real-time detection, diagnosis, and therapy monitoring of skin diseases. Implementation of these technologies into clinical research and practice requires clinicians to have an understanding of their capabilities, benefits, and limitations. This concise review provides insights on the application of OCT, RCM, and MPM for clinical skin imaging through images acquired in vivo from the same lesions. The presented data are limited to pigmented lesions and basal cell carcinoma.
Collapse
Affiliation(s)
- Griffin Lentsch
- Beckman Laser Institute and Medical Clinic, University of California, Irvine, California, USA
| | - Erica G. Baugh
- Department of Dermatology, University of California, Irvine, California, USA
| | - Bonnie Lee
- Department of Dermatology, University of California, Irvine, California, USA
| | - Michelle Aszterbaum
- Department of Dermatology, University of California, Irvine, California, USA
| | | | - Kristen M. Kelly
- Beckman Laser Institute and Medical Clinic, University of California, Irvine, California, USA,Department of Dermatology, University of California, Irvine, California, USA
| | - Mihaela Balu
- Beckman Laser Institute and Medical Clinic, University of California, Irvine, California, USA
| |
Collapse
|
155
|
Abstract
The aim of this review paper is to concentrate on the use and application of photonics in dentistry. More than one hundred review and research articles were comprehensively analysed in terms of applications of photonics in dentistry, including surgical applications, as well as dental biomaterials, diagnosis and treatments. In biomedical engineering, various fields, such as biology, chemistry, material and physics, come together in to tackle a disease/disorder either as a diagnostic tool or an option for treatment. Engineers believe that biophotonics is the application of photonics in medicine, whereas photonics is simply a technology for creating and connecting packets of light energy, known as photons. This review paper provides a comprehensive discussion of its main elements, such as photoelasticity, interferometry techniques, optical coherence tomography, different types of lasers, carbon nanotubes, graphene and quantum dots.
Collapse
|
156
|
Arikkatt AJ, Węgrzyński Ł, Bartnik A, Fiedorowicz H, Wachulak P. Laboratory system for optical coherence tomography (OCT) using a laser plasma source of soft x-rays and extreme ultraviolet and focusing ellipsoidal optics. OPTICS EXPRESS 2022; 30:13491-13509. [PMID: 35472960 DOI: 10.1364/oe.454656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Accepted: 03/13/2022] [Indexed: 06/14/2023]
Abstract
Optical coherence tomography (OCT) with the use of soft x-rays (SXR) and extreme ultraviolet (EUV) has been recently demonstrated [Fuchs et al. Sci. Rep.6, 20658 (2016)10.1038/srep20658; Fuchs et al. Optica4, 903 (2017)10.1364/OPTICA.4.000903]. This new imaging technique, named XCT, makes it possible to obtain cross-sectional and tomographic images of objects with nanometer spatial resolution. The article presents a newly developed laboratory system for XCT using a compact laser plasma light source operating in the SXR and EUV spectral ranges. The source is based on a gas puff target containing Kr gas or a Kr/Xe gas mixture irradiated with nanosecond laser pulses from an Nd:YAG laser. The use of the gas puff target enables efficient emission of SXR and EUV radiation without generating target debris associated with laser ablation when using a solid target. The system is equipped with an ellipsoidal mirror to collect radiation from the source and focus on the imaged object. The XCT measurements are made by processing the spectrum of the radiation reflected from the object recorded with a transmission grating spectrometer equipped with an identical focusing mirror and a CCD camera. The paper presents the characterization and optimization of the new XCT system and its application to the measurements of layered nanostructures.
Collapse
|
157
|
An Overview of Terahertz Imaging with Resonant Tunneling Diodes. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12083822] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Terahertz (THz) imaging is a rapidly growing application motivated by industrial demands including harmless (non-ionizing) security imaging, multilayer paint quality control within the automotive industry, insulating foam non-invasive testing in aerospace, and biomedical diagnostics. One of the key components in the imaging system is the source and detector. This paper gives a brief overview of room temperature THz transceiver technology for imaging applications based on the emerging resonant tunneling diode (RTD) devices. The reported results demonstrate that RTD technology is a very promising candidate to realize compact, low-cost THz imaging systems.
Collapse
|
158
|
Wanderi K, Cui Z. Organic fluorescent nanoprobes with NIR-IIb characteristics for deep learning. EXPLORATION (BEIJING, CHINA) 2022; 2:20210097. [PMID: 37323884 PMCID: PMC10191020 DOI: 10.1002/exp.20210097] [Citation(s) in RCA: 34] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Accepted: 01/06/2022] [Indexed: 06/15/2023]
Abstract
Illumination of biological events with near-infrared II sub-channel (NIR-IIb, 1500-1700 nm) enhances the transparency of biological tissues, which is very attractive for deep imaging. Due to the long-wavelength, which reduces optical damage, suppresses autofluorescence, and obviates light scattering, NIR-IIb nanoprobes afford deep tissue penetration with unprecedented spatiotemporal resolution. Hence, NIR-IIb imaging facilitates deep learning and decipherment of biological proceedings in living organisms with astounding high clarity. In comparison to its predecessors in the visible-near-infrared spectrum, imaging in the NIR-IIb has shown great potential for tissue imaging and extrapolating imaging applications for clinical studies. However, the use of organic fluorescent nanoprobes (OFNPs) in the NIR-IIb region is still rare since it is in its early stages. Thus, herein we aim to survey the recent development of different organic fluorescent nanomaterials with NIR-IIb characteristics, their unique photophysical properties, and their utilization in deep imaging in animal models. Further, practical researches on organic fluorescent nanoprobes with NIR-IIb emission and their transition to clinical applications are highlighted.
Collapse
Affiliation(s)
- Kevin Wanderi
- State Key Laboratory of VirologyWuhan Institute of VirologyCenter for Biosafety Mega‐ScienceChinese Academy of SciencesWuhanChina
- Department of Analytical Microbiology and NanobiologyUniversity of Chinese Academy of SciencesBeijingChina
| | - Zongqiang Cui
- State Key Laboratory of VirologyWuhan Institute of VirologyCenter for Biosafety Mega‐ScienceChinese Academy of SciencesWuhanChina
| |
Collapse
|
159
|
Chen C, Zhang W, Liang Y. Evaluation of apical root defects during canal instrumentation with two different nickel-titanium (NiTi) systems by optical coherence tomography (OCT) scan. J Dent Sci 2022; 17:763-770. [PMID: 35756775 PMCID: PMC9201542 DOI: 10.1016/j.jds.2021.10.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Revised: 10/02/2021] [Indexed: 01/20/2023] Open
|
160
|
Singh LK, Garg H, Khanna M. Performance evaluation of various deep learning based models for effective glaucoma evaluation using optical coherence tomography images. MULTIMEDIA TOOLS AND APPLICATIONS 2022; 81:27737-27781. [PMID: 35368855 PMCID: PMC8962290 DOI: 10.1007/s11042-022-12826-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Revised: 02/20/2022] [Accepted: 03/09/2022] [Indexed: 06/14/2023]
Abstract
Glaucoma is the dominant reason for irreversible blindness worldwide, and its best remedy is early and timely detection. Optical coherence tomography has come to be the most commonly used imaging modality in detecting glaucomatous damage in recent years. Deep Learning using Optical Coherence Tomography Modality helps in predicting glaucoma more accurately and less tediously. This experimental study aims to perform glaucoma prediction using eight different ImageNet models from Optical Coherence Tomography of Glaucoma. A thorough investigation is performed to evaluate these models' performances on various efficiency metrics, which will help discover the best performing model. Every net is tested on three different optimizers, namely Adam, Root Mean Squared Propagation, and Stochastic Gradient Descent, to find the best relevant results. An attempt has been made to improvise the performance of models using transfer learning and fine-tuning. The work presented in this study was initially trained and tested on a private database that consists of 4220 images (2110 normal optical coherence tomography and 2110 glaucoma optical coherence tomography). Based on the results, the four best-performing models are shortlisted. Later, these models are tested on the well-recognized standard public Mendeley dataset. Experimental results illustrate that VGG16 using the Root Mean Squared Propagation Optimizer attains auspicious performance with 95.68% accuracy. The proposed work concludes that different ImageNet models are a good alternative as a computer-based automatic glaucoma screening system. This fully automated system has a lot of potential to tell the difference between normal Optical Coherence Tomography and glaucomatous Optical Coherence Tomography automatically. The proposed system helps in efficiently detecting this retinal infection in suspected patients for better diagnosis to avoid vision loss and also decreases senior ophthalmologists' (experts) precious time and involvement.
Collapse
Affiliation(s)
- Law Kumar Singh
- Department of Computer Science and Engineering, Sharda University , Greater Noida, India
- Department of Computer Science and Engineering, Hindustan College of Science and Technology, Mathura, India
| | - Hitendra Garg
- Department of Computer Engineering and Applications, GLA University, Mathura, India
| | - Munish Khanna
- Department of Computer Science and Engineering, Hindustan College of Science and Technology, Mathura, India
| |
Collapse
|
161
|
Finite Element Analysis of the Epiretinal Membrane Contraction. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12052623] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/10/2022]
Abstract
The epiretinal membrane is a thin sheet of fibrous tissue that can form over the macular area of the retina, and may result in the loss of visual acuity or metamorphopsia, due to superficial retinal folds. A vitrectomy surgery, the current treatment procedure for this pathology, is only performed after symptoms are present. However, sometimes the patients do not present any vision improvements after the surgery. The use of computational methods for a patient-specific biomechanical analysis can contribute to better understanding the mechanisms behind the success or failure of a vitrectomy. Using medical data from two patients who underwent a vitrectomy, one with substantial improvements and another with no improvements, an analysis of the retinal displacement due to the contraction of the epiretinal membrane was performed. Our results suggest a causal effect between the magnitude of the retinal displacements caused by the epiretinal membrane contraction and the outcome of the vitrectomy procedure.
Collapse
|
162
|
Role of Anterior Segment-Optical Coherence Tomography Angiography in Acute Ocular Burns. Diagnostics (Basel) 2022; 12:diagnostics12030607. [PMID: 35328160 PMCID: PMC8947509 DOI: 10.3390/diagnostics12030607] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2022] [Revised: 02/09/2022] [Accepted: 02/21/2022] [Indexed: 02/01/2023] Open
Abstract
Acute ocular burns have varied manifestations which require prompt diagnosis and management to prevent chronic sequelae. Of these, the detection of limbal ischemia poses a challenge because of the subjective nature of its clinical signs. Anterior segment optical coherence tomography angiography (AS-OCTA) offers an objective method of assessing ischemia in these eyes. This review provides an overview of the technology of AS-OCTA and its applications in acute burns. AS-OCTA generates images by isolating the movement of erythrocytes within blood vessels from sequentially obtained b-scans. Limbal ischemia manifests in these scans as absent vasculature and the extent of ischemia can be quantified using different vessel-related parameters. Of these, the density of vessels is most commonly used and correlates with the severity of the injury. Incorporation of the degree of ischemia in the classification of acute burns has been attempted in animal studies and its extension to human trials may provide an added dimension in determining the final prognosis of these eyes. Thus, AS-OCTA is a promising device that can objectively evaluate limbal ischemia. This will facilitate the identification of patients who will benefit from revascularization therapies and stem cell transplants in acute and chronic ocular burns, respectively.
Collapse
|
163
|
Is Real-Time Microscopy on the Horizon? A Brief Review of the Potential Future Directions in Clinical Breast Tumor Microscopy Implementation. Virchows Arch 2022; 480:211-227. [PMID: 35218378 DOI: 10.1007/s00428-022-03300-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2021] [Revised: 01/16/2022] [Accepted: 01/21/2022] [Indexed: 10/19/2022]
Abstract
We will briefly review the current paradigm and some recent developments in the area of clinical breast microscopy, highlighting several promising commercially available, and research-based platforms. Confocal microscopy (reflectance, fluorescence, and spectrally encoded), optical coherence tomography (wide field and full field), stereomicroscopy, open-top light sheet microscopy, microscopy with ultraviolet surface excitation, nonlinear microscopy, Raman scattering microscopy, photoacoustic microscopy, and needle microendoscopy will be discussed. Non-microscopic methods for breast pathology assessment are beyond the scope of this review. These microscopic technologies have to varying degrees the potential for transforming breast cancer care, but in order for any of these to be integrated into clinical practice there are several hurdles to overcome. In our review we will focus on what needs to be done in order for the commercially available technologies to become more established, what the technologies in the research domain need to do in order to reach the commercial realm; and finally, what the field of breast pathology might look like if these technologies were to be widely adopted.
Collapse
|
164
|
Thapa D, Welch R, Dabas RP, Salimi M, Tavakolian P, Sivagurunathan K, Ngai K, Huang B, Finer Y, Abrams S, Mandelis A, Tabatabaei N. Comparison of Long-Wave and Mid-Wave Infrared Imaging Modalities for Photothermal Coherence Tomography of Human Teeth. IEEE Trans Biomed Eng 2022; 69:2755-2766. [PMID: 35196221 DOI: 10.1109/tbme.2022.3153209] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The ability to detect dental caries at early stages lies at the heart of minimal intervention dentistry, enabling the curing or arresting of carious lesions before they advance to the cavity stage. Enhanced truncated-correlation photothermal coherence tomography (eTC-PCT) using mid-wave infrared (MWIR) cameras has recently been shown to offer tomographic visualization of early caries. The tomographic slicing ability of such systems, however, is believed to be limited by direct radiative thermal emission through the translucent dental enamel in the 3-5 m MWIR spectral range. Such radiative emissions can dominate the delayed conductive thermal contributions needed for tomographic reconstruction of internal dental defects. It has been hypothesized that long-wave infrared (LWIR) eTC-PCT systems may offer better tomographic performance by taking advantage of the intrinsic attenuation of direct radiative emission by dental enamel in the LWIR spectral range, enabling more effective delayed conductive thermal contributions from subsurface caries. More than an order of magnitude lower cost of the system is another key attribute of LWIR eTC-PCT which can open the door for downstream translation of the technology to clinics. In this report, we offer a systematic comparison of the performance/effectiveness of caries detection with LWIR and MWIR eTC-PCT systems for detecting natural caries, bacterial caries, and artificially demineralized enamel surfaces. Our results suggest that the low-cost LWIR based eTC-PCT system provides 3D visualization and 2D slice-by-slice images of early caries and internal micro-cracks similar to those obtained from the more expensive MWIR-based eTC-PCT system, albeit with ~1.3dB lower signal-to-noise ratio.
Collapse
|
165
|
Maupu C, Lebas H, Boulaftali Y. Imaging Modalities for Intracranial Aneurysm: More Than Meets the Eye. Front Cardiovasc Med 2022; 9:793072. [PMID: 35242823 PMCID: PMC8885801 DOI: 10.3389/fcvm.2022.793072] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Accepted: 01/17/2022] [Indexed: 11/21/2022] Open
Abstract
Intracranial aneurysms (IA) are often asymptomatic and have a prevalence of 3 to 5% in the adult population. The risk of IA rupture is low, however when it occurs half of the patients dies from subarachnoid hemorrhage (SAH). To avoid this fatal evolution, the main treatment is an invasive surgical procedure, which is considered to be at high risk of rupture. This risk score of IA rupture is evaluated mainly according to its size and location. Therefore, angiography and anatomic imaging of the intracranial aneurysm are crucial for its diagnosis. Moreover, it has become obvious in recent years that several other factors are implied in this complication, such as the blood flow complexity or inflammation. These recent findings lead to the development of new IA imaging tools such as vessel wall imaging, 4D-MRI, or molecular MRI to visualize inflammation at the site of IA in human and animal models. In this review, we will summarize IA imaging techniques used for the patients and those currently in development.
Collapse
|
166
|
Directional analysis of intensity changes for determining the existence of cyst in optical coherence tomography images. Sci Rep 2022; 12:2105. [PMID: 35136133 PMCID: PMC8825816 DOI: 10.1038/s41598-022-06099-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2021] [Accepted: 01/24/2022] [Indexed: 11/23/2022] Open
Abstract
Diabetic retinopathy (DR) is an important cause of blindness in people with the long history of diabetes. DR is caused due to the damage to blood vessels in the retina. One of the most important manifestations of DR is the formation of fluid-filled regions between retinal layers. The evaluation of stage and transcribed drugs can be possible through the analysis of retinal Optical Coherence Tomography (OCT) images. Therefore, the detection of cysts in OCT images and the is of considerable importance. In this paper, a fast method is proposed to determine the status of OCT images as cystic or non-cystic. The method consists of three phases which are pre-processing, boundary pixel determination and post-processing. After applying a noise reduction method in the pre-processing step, the method finds the pixels which are the boundary pixels of cysts. This process is performed by finding the significant intensity changes in the vertical direction and considering rectangular patches around the candidate pixels. The patches are verified whether or not they contain enough pixels making considerable diagonal intensity changes. Then, a shadow omission method is proposed in the post-processing phase to extract the shadow regions which can be mistakenly considered as cystic areas. Then, the pixels extracted in the previous phase that are near the shadow regions are removed to prevent the production of false positive cases. The performance of the proposed method is evaluated in terms of sensitivity and specificity on real datasets. The experimental results show that the proposed method produces outstanding results from both accuracy and speed points of view.
Collapse
|
167
|
Engineered nanomaterials for synergistic photo-immunotherapy. Biomaterials 2022; 282:121425. [DOI: 10.1016/j.biomaterials.2022.121425] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2021] [Revised: 01/19/2022] [Accepted: 02/17/2022] [Indexed: 02/07/2023]
|
168
|
Li J, Shang C, Rong Y, Sun J, Cheng Y, He B, Wang Z, Li M, Ma J, Fu B, Ji X. Review on Laser Technology in Intravascular Imaging and Treatment. Aging Dis 2022; 13:246-266. [PMID: 35111372 PMCID: PMC8782552 DOI: 10.14336/ad.2021.0711] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2021] [Accepted: 07/11/2021] [Indexed: 12/14/2022] Open
Abstract
Blood vessels are one of the most essential organs, which nourish all tissues in our body. Once there are intravascular plaques or vascular occlusion, other organs and circulatory systems will not work properly. Therefore, it is necessary to detect abnormal blood vessels by intravascular imaging technologies for subsequent vascular treatment. The emergence of lasers and fiber optics promotes the development of intravascular imaging and treatment. Laser imaging techniques can obtain deep vascular images owing to light scattering and absorption properties. Moreover, photothermal and photomechanical effects of laser make it possible to treat vascular diseases accurately. In this review, we present the research progress and applications of laser techniques in intravascular imaging and treatment. Firstly, we introduce intravascular optical coherent tomography and intravascular photoacoustic imaging, which can obtain various information of plaques. Multimodal intravascular imaging techniques provide more information about intravascular plaques, which have an essential influence on intravascular imaging. Secondly, two laser techniques including laser angioplasty and endovenous laser ablation are discussed for the treatment of arterial and venous diseases, respectively. Finally, the outlook of laser techniques in blood vessels, as well as the integration of laser imaging and treatment are prospected in the section of discussions.
Collapse
Affiliation(s)
- Jing Li
- BUAA-CCMU Advanced Innovation Center for Big Data-Based Precision Medicine, School of Engineering Medicine, Beihang University, Beijing, China.
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China.
| | - Ce Shang
- BUAA-CCMU Advanced Innovation Center for Big Data-Based Precision Medicine, School of Engineering Medicine, Beihang University, Beijing, China.
- School of Biological Science and Medical Engineering, Beihang University, Beijing, China.
| | - Yao Rong
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China.
- Medical Engineering Devices of Xuanwu Hospital, Capital Medical University, Beijing, China.
| | - Jingxuan Sun
- BUAA-CCMU Advanced Innovation Center for Big Data-Based Precision Medicine, School of Engineering Medicine, Beihang University, Beijing, China.
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China.
| | - Yuan Cheng
- BUAA-CCMU Advanced Innovation Center for Big Data-Based Precision Medicine, School of Engineering Medicine, Beihang University, Beijing, China.
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China.
| | - Boqu He
- BUAA-CCMU Advanced Innovation Center for Big Data-Based Precision Medicine, School of Engineering Medicine, Beihang University, Beijing, China.
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China.
| | - Zihao Wang
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China.
| | - Ming Li
- China-America Institute of Neuroscience, Xuanwu Hospital, Capital Medical University, Beijing, China.
| | - Jianguo Ma
- BUAA-CCMU Advanced Innovation Center for Big Data-Based Precision Medicine, School of Engineering Medicine, Beihang University, Beijing, China.
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China.
| | - Bo Fu
- BUAA-CCMU Advanced Innovation Center for Big Data-Based Precision Medicine, School of Engineering Medicine, Beihang University, Beijing, China.
- School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China.
- Key Laboratory of Big Data-Based Precision Medicine Ministry of Industry and Information Technology, Interdisciplinary Innovation Institute of Medicine and Engineering, Beihang University, Beijing, China.
| | - Xunming Ji
- BUAA-CCMU Advanced Innovation Center for Big Data-Based Precision Medicine, School of Engineering Medicine, Beihang University, Beijing, China.
- China-America Institute of Neuroscience, Xuanwu Hospital, Capital Medical University, Beijing, China.
- Neurosurgery Department of Xuanwu Hospital, Capital Medical University, Beijing, China.
| |
Collapse
|
169
|
Ji Y, Yang S, Zhou K, Rocliffe HR, Pellicoro A, Cash JL, Wang R, Li C, Huang Z. Deep-learning approach for automated thickness measurement of epithelial tissue and scab using optical coherence tomography. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:015002. [PMID: 35043611 PMCID: PMC8765552 DOI: 10.1117/1.jbo.27.1.015002] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Accepted: 11/23/2021] [Indexed: 10/29/2023]
Abstract
SIGNIFICANCE In order to elucidate therapeutic treatment to accelerate wound healing, it is crucial to understand the process underlying skin wound healing, especially re-epithelialization. Epidermis and scab detection is of importance in the wound healing process as their thickness is a vital indicator to judge whether the re-epithelialization process is normal or not. Since optical coherence tomography (OCT) is a real-time and non-invasive imaging technique that can perform a cross-sectional evaluation of tissue microstructure, it is an ideal imaging modality to monitor the thickness change of epidermal and scab tissues during wound healing processes in micron-level resolution. Traditional segmentation on epidermal and scab regions was performed manually, which is time-consuming and impractical in real time. AIM We aim to develop a deep-learning-based skin layer segmentation method for automated quantitative assessment of the thickness of in vivo epidermis and scab tissues during a time course of healing within a rodent model. APPROACH Five convolution neural networks were trained using manually labeled epidermis and scab regions segmentation from 1000 OCT B-scan images (assisted by its corresponding angiographic information). The segmentation performance of five segmentation architectures was compared qualitatively and quantitatively for validation set. RESULTS Our results show higher accuracy and higher speed of the calculated thickness compared with human experts. The U-Net architecture represents a better performance than other deep neural network architectures with 0.894 at F1-score, 0.875 at mean intersection over union, 0.933 at Dice similarity coefficient, and 18.28 μm at an average symmetric surface distance. Furthermore, our algorithm is able to provide abundant quantitative parameters of the wound based on its corresponding thickness maps in different healing phases. Among them, normalized epidermal thickness is recommended as an essential hallmark to describe the re-epithelialization process of the rodent model. CONCLUSIONS The automatic segmentation and thickness measurements within different phases of wound healing data demonstrates that our pipeline provides a robust, quantitative, and accurate method for serving as a standard model for further research into effect of external pharmacological and physical factors.
Collapse
Affiliation(s)
- Yubo Ji
- University of Dundee, School of Science and Engineering, Dundee, United Kingdom
| | - Shufan Yang
- Edinburgh Napier University, School of Computing, Edinburgh, United Kingdom
- University of Glasgow, Center of Medical and Industrial Ultrasonics, Glasgow, United Kingdom
| | - Kanheng Zhou
- University of Dundee, School of Science and Engineering, Dundee, United Kingdom
| | - Holly R. Rocliffe
- The University of Edinburgh, The Queen’s Medical Research Institute, MRC Centre for Inflammation Research, Edinburgh, United Kingdom
| | - Antonella Pellicoro
- The University of Edinburgh, The Queen’s Medical Research Institute, MRC Centre for Inflammation Research, Edinburgh, United Kingdom
| | - Jenna L. Cash
- The University of Edinburgh, The Queen’s Medical Research Institute, MRC Centre for Inflammation Research, Edinburgh, United Kingdom
| | - Ruikang Wang
- University of Washington, Department of Bioengineering, Seattle, Washington, United States
| | - Chunhui Li
- University of Dundee, School of Science and Engineering, Dundee, United Kingdom
| | - Zhihong Huang
- University of Dundee, School of Science and Engineering, Dundee, United Kingdom
| |
Collapse
|
170
|
Manubolu VS, Budoff MJ, Lakshmanan S. Multimodality Imaging Trials Evaluating the Impact of Omega-3 Fatty Acids on Coronary Artery Plaque Characteristics and Burden. Heart Int 2022. [DOI: 10.17925/hi.2022.16.1.2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Treatment of established risk factors, especially low-density lipoprotein (LDL) cholesterol, is the cornerstone of preventing atherosclerotic coronary artery disease. Despite reducing LDL cholesterol, there remains a significant risk of cardiovascular disease. Inflammatory and metabolic pathways contribute to recurrence of cardiovascular events, and are often missed in clinical practice. Eicosapentaenoic acid (EPA) may play a crucial role in reducing residual risk of cardiovascular disease. In this review we discuss the clinical applications of omega-3 fatty acids (OM3FAs), their mechanism of action, the difference between pure EPA and docosahexaenoic acid components, and the latest cardiovascular outcome trials and imaging trials evaluating coronary plaque. PubMed and EMBASE were searched to include all the remarkable clinical trials investigating OM3FAs and cardiovascular disease. Beyond statins, additional medications are required to reduce the risk of cardiovascular disease. EPA has shown cardiovascular benefit in addition to statins in large outcome trials. Additionally, multiple serial-imaging studies have demonstrated benefits on plaque progression and stabilization. Due to its pleotropic properties, icosapent ethyl outperforms other OM3FAs in decreasing cardiovascular disease risk in both patients with and without high triglycerides, and is currently recommended as an adjunct to statins. To further strengthen the current evidence, additional research is required to elucidate the inconsistencies between the effects of pure EPA and EPA plus docosahexaenoic acid.
Collapse
|
171
|
Kholiqov O, Zhou W, Zhang T, Zhao M, Ghandiparsi S, Srinivasan VJ. Scanning interferometric near-infrared spectroscopy. OPTICS LETTERS 2022; 47:110-113. [PMID: 34951892 PMCID: PMC9281567 DOI: 10.1364/ol.443533] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Accepted: 11/19/2021] [Indexed: 05/24/2023]
Abstract
In diffuse optics, quantitative assessment of the human brain is confounded by the skull and scalp. To better understand these superficial tissues, we advance interferometric near-infrared spectroscopy (iNIRS) to form images of the human superficial forehead blood flow index (BFI). We present a null source-collector (S-C) polarization splitting approach that enables galvanometer scanning and eliminates unwanted backscattered light. Images show an order-of-magnitude heterogeneity in superficial dynamics, implying an order-of-magnitude heterogeneity in brain specificity, depending on forehead location. Along the time-of-flight dimension, autocorrelation decay rates support a three-layer model with increasing BFI from the skull to the scalp to the brain. By accurately characterizing superficial tissues, this approach can help improve specificity for the human brain.
Collapse
Affiliation(s)
- Oybek Kholiqov
- Department of Biomedical Engineering, University of California Davis, Davis, California 95616, USA
| | - Wenjun Zhou
- Department of Biomedical Engineering, University of California Davis, Davis, California 95616, USA
| | - Tingwei Zhang
- Department of Biomedical Engineering, University of California Davis, Davis, California 95616, USA
| | - Mingjun Zhao
- Department of Biomedical Engineering, University of California Davis, Davis, California 95616, USA
- Tech4Health Institute, NYU Langone Health, New York, New York 10010, USA
| | - Soroush Ghandiparsi
- Department of Biomedical Engineering, University of California Davis, Davis, California 95616, USA
| | - Vivek J. Srinivasan
- Department of Biomedical Engineering, University of California Davis, Davis, California 95616, USA
- Tech4Health Institute, NYU Langone Health, New York, New York 10010, USA
| |
Collapse
|
172
|
Nuijts MA, Imhof SM, Veldhuis N, Dekkers CC, Schouten – van Meeteren AYN, Stegeman I. The diagnostic accuracy and prognostic value of OCT for the evaluation of the visual function in children with a brain tumour: A systematic review. PLoS One 2021; 16:e0261631. [PMID: 34941930 PMCID: PMC8699950 DOI: 10.1371/journal.pone.0261631] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Accepted: 12/06/2021] [Indexed: 12/22/2022] Open
Abstract
Purpose To systematically review the evidence on the diagnostic accuracy and prognostic value of retinal optical coherence tomography (OCT) to detect visual acuity (VA) or visual field (VF) loss in children with a brain tumour. Methods PubMed, Embase and Cochrane Library databases were searched from inception to February 2021. We included studies evaluating retinal OCT and standard visual function parameters (VA and or VF) in children with a brain tumour. Two authors independently extracted data from each included study. They also assessed the methodological quality of the studies using the QUADAS-2 or QUIPS tool. The diagnostic accuracy of OCT was evaluated with receiver operating characteristic analysis, sensitivity, specificity, positive predictive value and negative predictive value. The prognostic value of OCT was evaluated with predictive measures (odds ratio). Results We included five diagnostic studies, with a total of 186 patients, all diagnosed with optic pathway glioma. No prognostic studies were eligible for inclusion. Included studies evaluated either retinal nerve fiber layer (RNFL) thickness or ganglion cell layer—inner plexiform layer (GCL-IPL) thickness. There was considerable heterogeneity between OCT devices, OCT protocols, visual function parameters and threshold values. Sensitivity and specificity for RNFL thickness measurement ranged from 60.0% to 100.0% and 76.6% to 100%, respectively. For GCL-IPL thickness measurement, area under the curve ranged from 0.91 to 0.98 for different diameters. Conclusion The literature regarding the diagnostic accuracy and prognostic value of OCT parameters in children with a brain tumour is scarce. Due to heterogeneity and a considerable risk of bias of included studies, we cannot draw solid conclusions regarding the accuracy of retinal OCT. Future research should investigate the potential of OCT as diagnostic and prognostic tool for the evaluation of the visual function and detection of visual impairment in children with any type of brain tumour.
Collapse
Affiliation(s)
- Myrthe A. Nuijts
- Department of Ophthalmology, University Medical Centre Utrecht, Utrecht, The Netherlands
- * E-mail:
| | - Saskia M. Imhof
- Department of Ophthalmology, University Medical Centre Utrecht, Utrecht, The Netherlands
| | - Nienke Veldhuis
- Faculty of Medicine, Utrecht University, Utrecht, The Netherlands
| | - Coco C. Dekkers
- Faculty of Medicine, Utrecht University, Utrecht, The Netherlands
| | | | - Inge Stegeman
- Department of Ophthalmology, University Medical Centre Utrecht, Utrecht, The Netherlands
- Department of Otorhinolaryngology and Head & Neck Surgery University, University Medical Centre Utrecht, Utrecht, The Netherlands
- Brain Centre Rudolf Magnus, University Medical Centre Utrecht, Utrecht, The Netherlands
- Epidemiology and Data Science, Amsterdam University Medical Centre, University of Amsterdam, Amsterdam, The Netherlands
| |
Collapse
|
173
|
Alis A, Guler Alis M. The effect of branch retinal vein occlusion on the vascular structure of the choroid. Photodiagnosis Photodyn Ther 2021; 37:102687. [PMID: 34923154 DOI: 10.1016/j.pdpdt.2021.102687] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Revised: 11/04/2021] [Accepted: 12/10/2021] [Indexed: 10/19/2022]
Abstract
OBJECTIVE Our aim is to examine choroidal structural changes in eyes with branch retinal vein occlusion (BRVO). MATERIAL AND METHOD This retrospective, comparative study included 34 newly diagnosed unilateral BRVO patients and 40 healthy controls. Subfoveal choroidal thickness (SFCT) measurement was performed with enhanced depth imaging optical coherence tomography (EDI-OCT). The images were binarized using the ImageJ software program. Total choroidal area (TCA), stromal area (SA), and luminal area (LA) were calculated from the 1500 µm area. The choroidal vascular index (CVI) was determined as the LA/TCA ratio. All parameter values were compared between the BRVO eye and the fellow eye, and the control group eyes. RESULTS Eyes with BRVO had a greater SA compared to both fellow and control eyes; hence, the CVI was lower (p < 0.001). LA did not differ between eyes. TCA, although not statistically significant, was larger in eyes with BRVO than in both fellow and control eyes. SFCT was also greater in eyes with BRVO. No correlation was observed between CVI and SFCT and best-corrected visual acuity (BCVA). CONCLUSION BRVO affects the stromal part of the choroid rather than its vascular structure. SA increases due to choroidal exudation that occurs in response to retinal ischemia, and CVI decreases accordingly.
Collapse
Affiliation(s)
- Abdulkadir Alis
- Fatih Sultan Mehmet Training and Research Hospital, Atasehir, Istanbul, Turkey.
| | - Meryem Guler Alis
- Fatih Sultan Mehmet Training and Research Hospital, Atasehir, Istanbul, Turkey
| |
Collapse
|
174
|
Tanos V, Neofytou M, Soliman ASA, Tanos P, Pattichis CS. Is Computer-Assisted Tissue Image Analysis the Future in Minimally Invasive Surgery? A Review on the Current Status of Its Applications. J Clin Med 2021; 10:jcm10245770. [PMID: 34945066 PMCID: PMC8706291 DOI: 10.3390/jcm10245770] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2021] [Revised: 11/22/2021] [Accepted: 11/29/2021] [Indexed: 11/16/2022] Open
Abstract
Purpose: Computer-assisted tissue image analysis (CATIA) enables an optical biopsy of human tissue during minimally invasive surgery and endoscopy. Thus far, it has been implemented in gastrointestinal, endometrial, and dermatologic examinations that use computational analysis and image texture feature systems. We review and evaluate the impact of in vivo optical biopsies performed by tissue image analysis on the surgeon’s diagnostic ability and sampling precision and investigate how operation complications could be minimized. Methods: We performed a literature search in PubMed, IEEE, Xplore, Elsevier, and Google Scholar, which yielded 28 relevant articles. Our literature review summarizes the available data on CATIA of human tissues and explores the possibilities of computer-assisted early disease diagnoses, including cancer. Results: Hysteroscopic image texture analysis of the endometrium successfully distinguished benign from malignant conditions up to 91% of the time. In dermatologic studies, the accuracy of distinguishing nevi melanoma from benign disease fluctuated from 73% to 81%. Skin biopsies of basal cell carcinoma and melanoma exhibited an accuracy of 92.4%, sensitivity of 99.1%, and specificity of 93.3% and distinguished nonmelanoma and normal lesions from benign precancerous lesions with 91.9% and 82.8% accuracy, respectively. Gastrointestinal and endometrial examinations are still at the experimental phase. Conclusions: CATIA is a promising application for distinguishing normal from abnormal tissues during endoscopic procedures and minimally invasive surgeries. However, the efficacy of computer-assisted diagnostics in distinguishing benign from malignant states is still not well documented. Prospective and randomized studies are needed before CATIA is implemented in clinical practice.
Collapse
Affiliation(s)
- Vasilios Tanos
- Department of Obstetrics and Gynecology, Aretaeio Hospital, 2024 Nicosia, Cyprus
- St. Georges’ Medical School, University of Nicosia, 2408 Nicosia, Cyprus;
- Correspondence:
| | - Marios Neofytou
- Biomedical Engineering Research Center, Department of Computer Science, University of Cyprus, 1678 Nicosia, Cyprus; (M.N.); (C.S.P.)
| | | | - Panayiotis Tanos
- Medical School, University of Aberdeen, Foresterhill Rd., Aberdeen AB25 2ZD, UK;
| | - Constantinos S. Pattichis
- Biomedical Engineering Research Center, Department of Computer Science, University of Cyprus, 1678 Nicosia, Cyprus; (M.N.); (C.S.P.)
| |
Collapse
|
175
|
Elsharkawy M, Elrazzaz M, Ghazal M, Alhalabi M, Soliman A, Mahmoud A, El-Daydamony E, Atwan A, Thanos A, Sandhu HS, Giridharan G, El-Baz A. Role of Optical Coherence Tomography Imaging in Predicting Progression of Age-Related Macular Disease: A Survey. Diagnostics (Basel) 2021; 11:2313. [PMID: 34943550 PMCID: PMC8699887 DOI: 10.3390/diagnostics11122313] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Revised: 12/03/2021] [Accepted: 12/07/2021] [Indexed: 11/16/2022] Open
Abstract
In developed countries, age-related macular degeneration (AMD), a retinal disease, is the main cause of vision loss in the elderly. Optical Coherence Tomography (OCT) is currently the gold standard for assessing individuals for initial AMD diagnosis. In this paper, we look at how OCT imaging can be used to diagnose AMD. Our main aim is to examine and compare automated computer-aided diagnostic (CAD) systems for diagnosing and grading of AMD. We provide a brief summary, outlining the main aspects of performance assessment and providing a basis for current research in AMD diagnosis. As a result, the only viable alternative is to prevent AMD and stop both this devastating eye condition and unwanted visual impairment. On the other hand, the grading of AMD is very important in order to detect early AMD and prevent patients from reaching advanced AMD disease. In light of this, we explore the remaining issues with automated systems for AMD detection based on OCT imaging, as well as potential directions for diagnosis and monitoring systems based on OCT imaging and telemedicine applications.
Collapse
Affiliation(s)
- Mohamed Elsharkawy
- Bioengineering Department, University of Louisville, Louisville, KY 40292, USA; (M.E.); (M.E.); (A.S.); (A.M.); (H.S.S.); (G.G.)
| | - Mostafa Elrazzaz
- Bioengineering Department, University of Louisville, Louisville, KY 40292, USA; (M.E.); (M.E.); (A.S.); (A.M.); (H.S.S.); (G.G.)
| | - Mohammed Ghazal
- Electrical and Computer Engineering Department, College of Engineering, Abu Dhabi University, Abu Dhabi 59911, United Arab Emirates; (M.G.); (M.A.)
| | - Marah Alhalabi
- Electrical and Computer Engineering Department, College of Engineering, Abu Dhabi University, Abu Dhabi 59911, United Arab Emirates; (M.G.); (M.A.)
| | - Ahmed Soliman
- Bioengineering Department, University of Louisville, Louisville, KY 40292, USA; (M.E.); (M.E.); (A.S.); (A.M.); (H.S.S.); (G.G.)
| | - Ali Mahmoud
- Bioengineering Department, University of Louisville, Louisville, KY 40292, USA; (M.E.); (M.E.); (A.S.); (A.M.); (H.S.S.); (G.G.)
| | - Eman El-Daydamony
- Faculty of Computers and Information, Mansoura University, Mansoura 35516, Egypt; (E.E.-D.); (A.A.)
| | - Ahmed Atwan
- Faculty of Computers and Information, Mansoura University, Mansoura 35516, Egypt; (E.E.-D.); (A.A.)
| | | | - Harpal Singh Sandhu
- Bioengineering Department, University of Louisville, Louisville, KY 40292, USA; (M.E.); (M.E.); (A.S.); (A.M.); (H.S.S.); (G.G.)
| | - Guruprasad Giridharan
- Bioengineering Department, University of Louisville, Louisville, KY 40292, USA; (M.E.); (M.E.); (A.S.); (A.M.); (H.S.S.); (G.G.)
| | - Ayman El-Baz
- Bioengineering Department, University of Louisville, Louisville, KY 40292, USA; (M.E.); (M.E.); (A.S.); (A.M.); (H.S.S.); (G.G.)
| |
Collapse
|
176
|
Li Y, Zhang M, Tupin S, Mitsuzuka K, Nakayama T, Anzai H, Ohta M. Flush Flow Behaviour Affected by the Morphology of Intravascular Endoscope: A Numerical Simulation and Experimental Study. Front Physiol 2021; 12:733767. [PMID: 34867440 PMCID: PMC8640206 DOI: 10.3389/fphys.2021.733767] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Accepted: 10/15/2021] [Indexed: 11/13/2022] Open
Abstract
Background: Whilst intravascular endoscopy can be used to identify lesions and assess the deployment of endovascular devices, it requires temporary blockage of the local blood flow during observation, posing a serious risk of ischaemia. Objective: To aid the design of a novel flow-blockage-free intravascular endoscope, we explored changes in the haemodynamic behaviour of the flush flow with respect to the flow injection speed and the system design. Methods: We first constructed the computational models for three candidate endoscope designs (i.e., Model A, B, and C). Using each of the three endoscopes, flow patterns in the target vessels (straight, bent, and twisted) under three different sets of boundary conditions (i.e., injection speed of the flush flow and the background blood flowrate) were then resolved through use of computational fluid dynamics and in vitro flow experiments. The design of endoscope and its optimal operating condition were evaluated in terms of the volume fraction within the vascular segment of interest, as well as the percentage of high-volume-fraction area (PHVFA) corresponding to three cross-sectional planes distal to the microcatheter tip. Results: With a mild narrowing at the endoscope neck, Model B exhibited the highest PHVFA, irrespective of location of the cross-sectional plane, compared with Models A and C which, respectively, had no narrowing and a moderate narrowing. The greatest difference in the PHVFA between the three models was observed on the cross-sectional plane 2 mm distal to the tip of the microcatheter (Model B: 33% vs. Model A: 18%). The background blood flowrate was found to have a strong impact on the resulting volume fraction of the flush flow close to the vascular wall, with the greatest difference being 44% (Model A). Conclusion: We found that the haemodynamic performance of endoscope Model B outperformed that of Models A and C, as it generated a flush flow that occupied the largest volume within the vascular segment of interest, suggesting that the endoscope design with a diameter narrowing of 30% at the endoscope neck might yield images of a better quality.
Collapse
Affiliation(s)
- Yujie Li
- Institute of Fluid Science, Tohoku University, Sendai, Japan.,Centre of Health Research, Torrens University Australia, Pyrmont, NSW, Australia
| | - Mingzi Zhang
- Institute of Fluid Science, Tohoku University, Sendai, Japan.,Faculty of Medicine, Health, and Human Sciences, Macquarie Medical School, Macquarie University, Sydney, NSW, Australia
| | - Simon Tupin
- Institute of Fluid Science, Tohoku University, Sendai, Japan
| | - Kohei Mitsuzuka
- Graduate School of Biomedical Engineering, Tohoku University, Sendai, Japan
| | - Toshio Nakayama
- Nara College, National Institute of Technology, Yamatokoriyama, Japan
| | - Hitomi Anzai
- Institute of Fluid Science, Tohoku University, Sendai, Japan
| | - Makoto Ohta
- Institute of Fluid Science, Tohoku University, Sendai, Japan
| |
Collapse
|
177
|
Affiliation(s)
- Hui Liu
- Shanxi Eye Hospital 100 Fudong St, Liu Xiang Shang Quan Xinghualing District, Taiyuan 030002, China
| | - Juan Cheng
- Shanxi Eye Hospital 100 Fudong St, Liu Xiang Shang Quan Xinghualing District, Taiyuan 030002, China
| |
Collapse
|
178
|
Polypoidal Choroidal Vasculopathy Diagnosis and Neovascular Activity Evaluation Using Optical Coherence Tomography Angiography. BIOMED RESEARCH INTERNATIONAL 2021; 2021:1637377. [PMID: 34825001 PMCID: PMC8610682 DOI: 10.1155/2021/1637377] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/11/2021] [Accepted: 11/05/2021] [Indexed: 11/17/2022]
Abstract
Purpose To examine choroidal neovascularization (CNV) characteristics in patients with exudative age-related macular degeneration (AMD) and polypoidal choroidal vasculopathy (PCV), using swept-source optical coherence tomography angiography (SS-OCTA), and investigate agreement with OCT B-scan, fundus fluorescein angiography (FFA), and indocyanine green angiography (ICGA) by two different examiners. Methods This is a retrospective multicentric study that involved patients with a history of AMD and PCV. Examiner A, who had access to OCTA, B-scan OCT, FFA, and ICGA imaging, had to differentiate between AMD and PCV, study the activity of AMD using Coscas' criteria (active vs. quiescent), and categorize PCV subtypes, while examiner B had only access to OCTA. Then, the diagnostic concordance was assessed between both examiners. Results A total of 27 patients (11 females (40.7%) and 16 males (59.3%), P = 0.231) were included in the analysis. Among those, 13 patients presented with neovascular AMD and 14 patients with PCV. There were 92.3% of correct answers regarding appropriate diagnosis and lesion characterization among AMD patients, against 61.5% of correct answers among PCV patients. The overall interrater reliability agreement between examiners, using Cohen's kappa coefficient (κ) was 0.70 (0.5082-0.8916). Disagreement was found with one active AMD misdiagnosed as inactive AMD, three inactive PCV misdiagnosed as inactive AMD, and one inactive PCV misdiagnosed as active AMD. Conclusion SS-OCTA alone remains limited in some specific phenotypes of PCV, which suggests the ongoing role of B-scan OCT associated with FFA and ICGA in the diagnosis of these conditions.
Collapse
|
179
|
Klontzas ME, Protonotarios A. High-Resolution Imaging for the Analysis and Reconstruction of 3D Microenvironments for Regenerative Medicine: An Application-Focused Review. Bioengineering (Basel) 2021; 8:182. [PMID: 34821748 PMCID: PMC8614770 DOI: 10.3390/bioengineering8110182] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Revised: 11/07/2021] [Accepted: 11/08/2021] [Indexed: 11/29/2022] Open
Abstract
The rapid evolution of regenerative medicine and its associated scientific fields, such as tissue engineering, has provided great promise for multiple applications where replacement and regeneration of damaged or lost tissue is required. In order to evaluate and optimise the tissue engineering techniques, visualisation of the material of interest is crucial. This includes monitoring of the cellular behaviour, extracellular matrix composition, scaffold structure, and other crucial elements of biomaterials. Non-invasive visualisation of artificial tissues is important at all stages of development and clinical translation. A variety of preclinical and clinical imaging methods-including confocal multiphoton microscopy, optical coherence tomography, magnetic resonance imaging (MRI), and computed tomography (CT)-have been used for the evaluation of artificial tissues. This review attempts to present the imaging methods available to assess the composition and quality of 3D microenvironments, as well as their integration with human tissues once implanted in the human body. The review provides tissue-specific application examples to demonstrate the applicability of such methods on cardiovascular, musculoskeletal, and neural tissue engineering.
Collapse
Affiliation(s)
- Michail E. Klontzas
- Department of Medical Imaging, University Hospital of Heraklion, 71110, Heraklion, Crete, Greece
- Computational Biomedicine Laboratory, Institute of Computer Science, Foundation for Research and Technology (FORTH), 70013 Heraklion, Crete, Greece
- Department of Radiology, School of Medicine, Voutes Campus, University of Crete, 71003 Heraklion, Crete, Greece
| | | |
Collapse
|
180
|
Hefner EM, Lin HC, Cole RC, Moore PA, McMullen RJ. Comparison of image quality of corneal and retinal optical coherence tomography using sedation and general anesthesia protocols with or without retrobulbar anesthesia in horses. Am J Vet Res 2021; 83:72-79. [PMID: 34727049 DOI: 10.2460/ajvr.21.02.0029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To compare image quality and acquisition time of corneal and retinal spectral domain optical coherence tomography (SD-OCT) under 3 different sedation-anesthesia conditions in horses. ANIMALS 6 middle-aged geldings free of ocular disease. PROCEDURES 1 randomly selected eye of each horse was evaluated via SD-OCT under the following 3 conditions: standing sedation without retrobulbar anesthetic block (RB), standing sedation with RB, and general anesthesia with RB. Five regions of interest were evaluated in the cornea (axial and 12, 3, 6, and 9 o'clock positions) and fundus (optic nerve head). Three diagnostic scans of predetermined quality were obtained per anatomical region. Image acquisition times and total scans per site were recorded. Corneal and retinal SD-OCT image quality was graded on a subjective scale from 0 (nondiagnostic) to 4 (excellent). RESULTS Mean values for the standing sedation without RB, standing sedation with RB, and general anesthesia conditions were 24, 23, and 17, respectively, for total cornea scan attempts; 23, 19, and 19 for total retina-scan attempts; 14.6, 13.2, and 9.2 minutes for total cornea scan time; 19.1, 9.2, and 13.0 for total retina scan time; 2.0, 2.3, and 2.5 for cornea grade; and 2.7, 2.9, and 2.5 for retina grade. CONCLUSIONS AND CLINICAL RELEVANCE The RB facilitated globe akinesia and improved the percentage of scans in frame and region of interest accuracy for retinal imaging via OCT in horses. Retrobulbar blocks improved clinical image acquisition while minimizing motion artifact.
Collapse
|
181
|
Thampi A, Hitchman S, Coen S, Vanholsbeeck F. Towards real time assessment of intramuscular fat content in meat using optical fiber-based optical coherence tomography. Meat Sci 2021; 181:108411. [DOI: 10.1016/j.meatsci.2020.108411] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2020] [Revised: 12/09/2020] [Accepted: 12/11/2020] [Indexed: 12/31/2022]
|
182
|
Wu Y, Szymanska M, Hu Y, Fazal MI, Jiang N, Yetisen AK, Cordeiro MF. Measures of disease activity in glaucoma. Biosens Bioelectron 2021; 196:113700. [PMID: 34653715 DOI: 10.1016/j.bios.2021.113700] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Revised: 10/01/2021] [Accepted: 10/08/2021] [Indexed: 12/13/2022]
Abstract
Glaucoma is the leading cause of irreversible blindness globally which significantly affects the quality of life and has a substantial economic impact. Effective detective methods are necessary to identify glaucoma as early as possible. Regular eye examinations are important for detecting the disease early and preventing deterioration of vision and quality of life. Current methods of measuring disease activity are powerful in describing the functional and structural changes in glaucomatous eyes. However, there is still a need for a novel tool to detect glaucoma earlier and more accurately. Tear fluid biomarker analysis and new imaging technology provide novel surrogate endpoints of glaucoma. Artificial intelligence is a post-diagnostic tool that can analyse ophthalmic test results. A detail review of currently used clinical tests in glaucoma include intraocular pressure test, visual field test and optical coherence tomography are presented. The advanced technologies for glaucoma measurement which can identify specific disease characteristics, as well as the mechanism, performance and future perspectives of these devices are highlighted. Applications of AI in diagnosis and prediction in glaucoma are mentioned. With the development in imaging tools, sensor technologies and artificial intelligence, diagnostic evaluation of glaucoma must assess more variables to facilitate earlier diagnosis and management in the future.
Collapse
Affiliation(s)
- Yue Wu
- Department of Surgery and Cancer, Imperial College London, South Kensington, London, United Kingdom; Department of Chemical Engineering, Imperial College London, South Kensington, London, United Kingdom
| | - Maja Szymanska
- The Imperial College Ophthalmic Research Group (ICORG), Imperial College London, London, United Kingdom
| | - Yubing Hu
- Department of Chemical Engineering, Imperial College London, South Kensington, London, United Kingdom.
| | - M Ihsan Fazal
- The Imperial College Ophthalmic Research Group (ICORG), Imperial College London, London, United Kingdom
| | - Nan Jiang
- West China School of Basic Medical Sciences & Forensic Medicine, Sichuan University, Chengdu, 610041, China
| | - Ali K Yetisen
- Department of Chemical Engineering, Imperial College London, South Kensington, London, United Kingdom
| | - M Francesca Cordeiro
- The Imperial College Ophthalmic Research Group (ICORG), Imperial College London, London, United Kingdom; The Western Eye Hospital, Imperial College Healthcare NHS Trust (ICHNT), London, United Kingdom; Glaucoma and Retinal Neurodegeneration Group, Department of Visual Neuroscience, UCL Institute of Ophthalmology, London, United Kingdom.
| |
Collapse
|
183
|
FULL-THICKNESS MACULAR HOLE SIZE BY HYPERTRANSMISSION SIGNAL ON SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY. Retina 2021; 41:2059-2065. [PMID: 33675334 DOI: 10.1097/iae.0000000000003163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
PURPOSE To assess the full-thickness macular hole (FTMH) size using the choroidal hypertransmission signal on spectral-domain optical coherence tomography and to compare this method to the standard aperture measurement of the minimum aperture size at the level of the neurosensory retina. DESIGN Cross-sectional study of retrospective data. METHODS Eyes with FTMH imaged on spectral-domain optical coherence tomography were included. Two independent masked graders used the device's built-in caliper tool to measure the FTMH minimum aperture size at the level of the neurosensory retina and the size of the corresponding hypertransmission signal below the level of the retinal pigment epithelium/Bruch membrane complex. To assess the reproducibility of the hypertransmission measurement in tilted scans, two measurements were obtained and compared; the first was traced parallel to the retinal pigment epithelium (parallel hypertransmission), and the second was horizontal to the image frame (horizontal hypertransmission), both using Image J software. RESULTS A total of 31 eyes were enrolled. The mean FTMH minimum aperture size was smaller compared with both the choroidal parallel hypertransmission and horizontal hypertransmission measurements (mean ± SD: 335.7 ± 139.5 µm, 376.7 ± 150.6 µm, 375.1 ± 150.0 µm, respectively. P < 0.001 for both comparisons). CONCLUSION The proposed hypertransmission measurement is a feasible and reproducible alternative to assess FTMH size and could provide the basis for an automated FTMH measurement on cross-sectional spectral-domain optical coherence tomography scans, as presented in this study, or on the spectral-domain optical coherence tomography volumetric data set by using an en face projection.
Collapse
|
184
|
Liu N, Chen X, Kimm MA, Stechele M, Chen X, Zhang Z, Wildgruber M, Ma X. In vivo optical molecular imaging of inflammation and immunity. J Mol Med (Berl) 2021; 99:1385-1398. [PMID: 34272967 DOI: 10.1007/s00109-021-02115-w] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2021] [Revised: 06/04/2021] [Accepted: 07/07/2021] [Indexed: 12/20/2022]
Abstract
Inflammation is the phenotypic form of various diseases. Recent development in molecular imaging provides new insights into the diagnostic and therapeutic evaluation of different inflammatory diseases as well as diseases involving inflammation such as cancer. While conventional imaging techniques used in the clinical setting provide only indirect measures of inflammation such as increased perfusion and altered endothelial permeability, optical imaging is able to report molecular information on diseased tissue and cells. Optical imaging is a quick, noninvasive, nonionizing, and easy-to-use diagnostic technology which has been successfully applied for preclinical research. Further development of optical imaging technology such as optoacoustic imaging overcomes the limitations of mere fluorescence imaging, thereby enabling pilot clinical applications in humans. By means of endogenous and exogenous contrast agents, sites of inflammation can be accurately visualized in vivo. This allows for early disease detection and specific disease characterization, enabling more rapid and targeted therapeutic interventions. In this review, we summarize currently available optical imaging techniques used to detect inflammation, including optical coherence tomography (OCT), bioluminescence, fluorescence, optoacoustics, and Raman spectroscopy. We discuss advantages and disadvantages of the different in vivo imaging applications with a special focus on targeting inflammation including immune cell tracking.
Collapse
Affiliation(s)
- Nian Liu
- State Key Laboratory of Natural Medicines, Key Laboratory of Drug Quality Control and Pharmacovigilance, Department of Pharmaceutical Analysis, China Pharmaceutical University, Nanjing, 210009, China
- Department of Chemistry, Technical University of Munich, 85747, Garching, Germany
| | - Xiao Chen
- Klinik und Poliklinik IV, University Hospital, LMU Munich, 80336, Munich, Germany
| | - Melanie A Kimm
- Department of Radiology, University Hospital, LMU Munich, 81337, Munich, Germany
| | - Matthias Stechele
- Department of Radiology, University Hospital, LMU Munich, 81337, Munich, Germany
| | - Xueli Chen
- School of Life Science and Technology, Xidian University, Xi'an 710126, China
| | - Zhimin Zhang
- School of Control Science and Engineering, Shandong University, Jinan, 250061, China
| | - Moritz Wildgruber
- Department of Radiology, University Hospital, LMU Munich, 81337, Munich, Germany
| | - Xiaopeng Ma
- School of Control Science and Engineering, Shandong University, Jinan, 250061, China.
| |
Collapse
|
185
|
Jung JM, Cho JY, Lee WJ, Chang SE, Lee MW, Won CH. Emerging Minimally Invasive Technologies for the Detection of Skin Cancer. J Pers Med 2021; 11:951. [PMID: 34683091 PMCID: PMC8538732 DOI: 10.3390/jpm11100951] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Revised: 09/23/2021] [Accepted: 09/23/2021] [Indexed: 12/23/2022] Open
Abstract
With the increasing incidence of skin cancer, many noninvasive technologies to detect its presence have been developed. This review focuses on reflectance confocal microscopy (RCM), optical coherence tomography (OCT), high-frequency ultrasound (HFUS), electrical impedance spectroscopy (EIS), pigmented lesion assay (PLA), and Raman spectroscopy (RS) and discusses the basic principle, clinical applications, advantages, and disadvantages of each technology. RCM provides high cellular resolution and has high sensitivity and specificity for the diagnosis of skin cancer. OCT provides lower resolution than RCM, although its evaluable depth is deeper than that of RCM. RCM and OCT may be useful in reducing the number of unnecessary biopsies, evaluating the tumor margin, and monitoring treatment response. HFUS can be mainly used to delineate tumor depths or margins and monitor the treatment response. EIS provides high sensitivity but low specificity for the diagnosis of skin malignancies. PLA, which is based on the genetic information of lesions, is applicable for the detection of melanoma with high sensitivity and moderate-to-high specificity. RS showed high accuracy for the diagnosis of skin cancer, although more clinical studies are required. Advances in these technologies for the diagnosis of skin cancer can lead to the realization of optimized and individualized treatments.
Collapse
Affiliation(s)
- Joon Min Jung
- Department of Dermatology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Korea; (J.M.J.); (W.J.L.); (S.E.C.); (M.W.L.)
| | - Ji Young Cho
- Department of Medical Science, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro 43-gil, Songpa-gu, Seoul 05505, Korea;
| | - Woo Jin Lee
- Department of Dermatology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Korea; (J.M.J.); (W.J.L.); (S.E.C.); (M.W.L.)
| | - Sung Eun Chang
- Department of Dermatology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Korea; (J.M.J.); (W.J.L.); (S.E.C.); (M.W.L.)
| | - Mi Woo Lee
- Department of Dermatology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Korea; (J.M.J.); (W.J.L.); (S.E.C.); (M.W.L.)
| | - Chong Hyun Won
- Department of Dermatology, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Korea; (J.M.J.); (W.J.L.); (S.E.C.); (M.W.L.)
| |
Collapse
|
186
|
Kolla AM, Liu L, Shaw K, Shapiro J, Femia A, Lo Sicco K. A narrative review of therapies for scalp dermatomyositis. Dermatol Ther 2021; 34:e15138. [PMID: 34549494 DOI: 10.1111/dth.15138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2021] [Revised: 09/08/2021] [Accepted: 09/19/2021] [Indexed: 11/30/2022]
Abstract
Cutaneous involvement of the scalp is a common manifestation of dermatomyositis (DM), occurring in up to 82% of adults with DM. Scalp DM predominantly affects women and is characterized by dermatitis, alopecia, pruritus, and/or burning. While cutaneous DM negatively impacts quality-of-life, scalp symptoms in particular are often severe, debilitating, and recalcitrant to standard DM therapies. Currently, there is a paucity of guidelines to inform management of scalp symptoms in patients with cutaneous DM. In this narrative review, we summarize the treatments utilized to manage scalp DM and highlight potential areas for future research. We identified eight studies that reported on 27 treatments focused on cutaneous DM and described outcomes on scalp symptoms. A majority of the treatments were standard therapies for cutaneous DM and resulted in no or minimal improvement in scalp symptoms. Five therapies did result in complete resolution of scalp symptoms and were recommended as potential areas of future research. These included low-dose naltrexone and platelet-rich plasma, as well as two frequent and one less common therapy for cutaneous DM respectively: intravenous immunoglobulin, rituximab, and apremilast. Though the literature was not systematically assessed in this review, these findings illustrate not only that strategies for refractory scalp DM are lacking, but also that those demonstrating potential efficacy are limited by low levels of evidence. Additional studies, especially randomized controlled trials, are needed to better inform management of scalp DM.
Collapse
Affiliation(s)
- Avani M Kolla
- The Ronald O. Perelman Department of Dermatology, NYU Grossman School of Medicine, New York, New York, USA
| | - Lynn Liu
- The Ronald O. Perelman Department of Dermatology, NYU Grossman School of Medicine, New York, New York, USA
| | - Katharina Shaw
- The Ronald O. Perelman Department of Dermatology, NYU Grossman School of Medicine, New York, New York, USA
| | - Jerry Shapiro
- The Ronald O. Perelman Department of Dermatology, NYU Grossman School of Medicine, New York, New York, USA
| | - Alisa Femia
- The Ronald O. Perelman Department of Dermatology, NYU Grossman School of Medicine, New York, New York, USA
| | - Kristen Lo Sicco
- The Ronald O. Perelman Department of Dermatology, NYU Grossman School of Medicine, New York, New York, USA
| |
Collapse
|
187
|
Patil MA, Kompella UB. Noninvasive monitoring of suprachoroidal, subretinal, and intravitreal implants using confocal scanning laser ophthalmoscope (cSLO) and optical coherence tomography (OCT). Int J Pharm 2021; 606:120887. [PMID: 34271155 PMCID: PMC8429194 DOI: 10.1016/j.ijpharm.2021.120887] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2021] [Revised: 07/08/2021] [Accepted: 07/11/2021] [Indexed: 11/28/2022]
Abstract
To address the need for noninvasive monitoring of injectable preformed drug delivery implants in the eye, we developed noninvasive methods to monitor such implants in different locations within the eye. Cylindrical polymeric poly(lactide-co-glycolide) or metal implants were injected into isolated bovine eyes at suprachoroidal, subretinal, and intravitreal locations and imaged noninvasively using the cSLO and OCT modes of a Heidelberg Spectralis HRA + OCT instrument after adjusting for the corneal curvature. Length and diameter of implants were obtained using cSLO images for all three locations, and the volume was calculated. Additionally, implant volume for suprachoroidal and subretinal location was estimated by integrating the cross-sectional bleb area over the implant length in multiple OCT images or using the maximum thickness of the implant based on thickness map along with length in cSLO image. Simultaneous cSLO and OCT imaging identified implants in different regions of the eye. Image-based measurements of implant dimensions mostly correlated well with the values prior to injection using blade micrometer. The accuracy (82-112%) and precision (1-19%) for noninvasive measurement of length was better than the diameter (accuracy 69-130%; precision 3-38%) using cSLO image for both types of implants. The accuracy for the measurement of volume of both types of implants from all three intraocular locations was better with cSLO imaging (42-152%) compared to those obtained using OCT cross-sectional bleb area integration (117-556%) or cSLO and thickness map (32-279%) methods. Suprachoroidal, subretinal, and intravitreal implants can be monitored for length, diameter, and volume using cSLO and OCT imaging. Such measurements may be useful in noninvasively monitoring implant degradation and drug release in the eye.
Collapse
Affiliation(s)
- Madhoosudan A Patil
- Department of Pharmaceutical Sciences, University of Colorado Anschutz Medical Campus, Aurora, CO, United States
| | - Uday B Kompella
- Department of Pharmaceutical Sciences, University of Colorado Anschutz Medical Campus, Aurora, CO, United States; Department of Ophthalmology, University of Colorado Anschutz Medical Campus, Aurora, CO, United States; Department of Bioengineering, University of Colorado Anschutz Medical Campus, Aurora, CO, United States; Colorado Center for Nanomedicine and Nanosafety, University of Colorado Anschutz Medical Campus, Aurora, CO, United States.
| |
Collapse
|
188
|
Hartmann K, Stein KP, Neyazi B, Sandalcioglu IE. Theranostic applications of optical coherence tomography in neurosurgery? Neurosurg Rev 2021; 45:421-427. [PMID: 34398385 PMCID: PMC8827310 DOI: 10.1007/s10143-021-01599-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Revised: 03/11/2021] [Accepted: 06/27/2021] [Indexed: 12/14/2022]
Abstract
In light of our own experiences, we value the existing literature to critically point out possible “near” future applications of optical coherence tomography (OCT) as an intraoperative neurosurgical guidance tool. “Pub Med”, “Cochrane Library”, “Crossref Metadata Search”, and “IEEE Xplore” databases as well as the search engine “Google Scholar” were screened for “optical coherence tomography + neurosurgery”, “optical coherence tomography + intraoperative imaging + neurosurgery”, and “microscope integrated optical coherence tomography + neurosurgery”. n = 51 articles related to the use of OCT as an imaging technique in the field of neurosurgery or neurosurgical research. n = 7 articles documented the intraoperative use of OCT in patients. n = 4 articles documented the use of microscope-integrated optical coherence tomography as a neurosurgical guidance tool. The Results demonstrate that OCT is the first imaging technique to study microanatomy in vivo. Postoperative analysis of intraoperative scans holds promise to enrich our physiological and pathophysiological understanding of the human brain. No data exists to prove that OCT-guided surgery minimizes perioperative morbidity or extends tumor resection. But results suggest that regular use of microscope-integrated OCT could increase security during certain critical microsurgical steps like, e.g., dural dissection at cavernous sinus, transtentorial approaches, or aneurysm clip placement. Endoscopy integration could aid surgery in regions which are not yet accessible to real-time imaging modalities like the ventricles or hypophysis. Theranostic instruments which combine OCT with laser ablation might gain importance in the emerging field of minimal invasive tumor surgery. OCT depicts vessel wall layers and its pathologies uniquely. Doppler OCT could further visualize blood flow in parallel. These abilities shed light on promising future applications in the field of vascular neurosurgery.
Collapse
Affiliation(s)
- Karl Hartmann
- Universitätsklinik Für Neurochirurgie, Otto-Von-Guericke-Universität Magdeburg, Leipziger Str. 44, 39120, Magdeburg, Deutschland.
| | - Klaus-Peter Stein
- Universitätsklinik Für Neurochirurgie, Otto-Von-Guericke-Universität Magdeburg, Leipziger Str. 44, 39120, Magdeburg, Deutschland
| | - Belal Neyazi
- Universitätsklinik Für Neurochirurgie, Otto-Von-Guericke-Universität Magdeburg, Leipziger Str. 44, 39120, Magdeburg, Deutschland
| | - I Erol Sandalcioglu
- Universitätsklinik Für Neurochirurgie, Otto-Von-Guericke-Universität Magdeburg, Leipziger Str. 44, 39120, Magdeburg, Deutschland
| |
Collapse
|
189
|
Lin SE, Jheng DY, Hsu KY, Liu YR, Huang WH, Lee HC, Tsai CC. Rapid pseudo-H&E imaging using a fluorescence-inbuilt optical coherence microscopic imaging system. BIOMEDICAL OPTICS EXPRESS 2021; 12:5139-5158. [PMID: 34513247 PMCID: PMC8407814 DOI: 10.1364/boe.431586] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 07/12/2021] [Accepted: 07/13/2021] [Indexed: 06/13/2023]
Abstract
A technique using Linnik-based optical coherence microscopy (OCM), with built-in fluorescence microscopy (FM), is demonstrated here to describe cellular-level morphology for fresh porcine and biobank tissue specimens. The proposed method utilizes color-coding to generate digital pseudo-H&E (p-H&E) images. Using the same camera, colocalized FM images are merged with corresponding morphological OCM images using a 24-bit RGB composition process to generate position-matched p-H&E images. From receipt of dissected fresh tissue piece to generation of stitched images, the total processing time is <15 min for a 1-cm2 specimen, which is on average two times faster than frozen-section H&E process for fatty or water-rich fresh tissue specimens. This technique was successfully used to scan human and animal fresh tissue pieces, demonstrating its applicability for both biobank and veterinary purposes. We provide an in-depth comparison between p-H&E and human frozen-section H&E images acquired from the same metastatic sentinel lymph node slice (∼10 µm thick), and show the differences, like elastic fibers of a tiny blood vessel and cytoplasm of tumor cells. This optical sectioning technique provides histopathologists with a convenient assessment method that outputs large-field H&E-like images of fresh tissue pieces without requiring any physical embedment.
Collapse
Affiliation(s)
- Sey-En Lin
- AcuSolutions Inc., 3F., No. 2, Ln. 263, Chongyang Rd., Nangang Dist., Taipei, Taiwan
- Department of Anatomic Pathology, New Taipei Municipal Tucheng Hospital (Built and operated by Chang Gung Medical Foundation), New Taipei City, Taiwan
| | - Dong-Yo Jheng
- AcuSolutions Inc., 3F., No. 2, Ln. 263, Chongyang Rd., Nangang Dist., Taipei, Taiwan
| | - Kuang-Yu Hsu
- AcuSolutions Inc., 3F., No. 2, Ln. 263, Chongyang Rd., Nangang Dist., Taipei, Taiwan
| | - Yun-Ru Liu
- Joint Biobank, Office of Human Research, Taipei Medical University, Taipei, Taiwan
| | - Wei-Hsiang Huang
- Graduate Institute of Molecular and Comparative Pathobiology, School of Veterinary Medicine, National Taiwan University, Taipei, Taiwan
| | - Hsiang-Chieh Lee
- Graduate Institute of Photonics and Optoelectronics, National Taiwan University, Taipei, Taiwan
- Department of Electrical Engineering, National Taiwan University, Taipei, Taiwan
| | - Chien-Chung Tsai
- AcuSolutions Inc., 3F., No. 2, Ln. 263, Chongyang Rd., Nangang Dist., Taipei, Taiwan
| |
Collapse
|
190
|
Abstract
In this review, the roles of detectors in various medical imaging techniques were described. Ultrasound, optical (near-infrared spectroscopy and optical coherence tomography) and thermal imaging, magnetic resonance imaging, computed tomography, single-photon emission tomography, positron emission tomography were the imaging modalities considered. For each methodology, the state of the art of detectors mainly used in the systems was described, emphasizing new technologies applied.
Collapse
|
191
|
Kim Y, Jung GI, Jeon D, Wijesinghe RE, Seong D, Lee J, Do WJ, Kwon SM, Lee JH, Hwang JH, Kim HD, Lee KB, Jeon M, Kim J. Non-Invasive Optical Coherence Tomography Data-Based Quantitative Algorithm for the Assessment of Residual Adhesive on Bracket-Removed Dental Surface. SENSORS (BASEL, SWITZERLAND) 2021; 21:4670. [PMID: 34300410 PMCID: PMC8309505 DOI: 10.3390/s21144670] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Revised: 06/30/2021] [Accepted: 07/05/2021] [Indexed: 11/17/2022]
Abstract
The aim of this study was to quantitatively assess the residual adhesive on orthodontic ceramic bracket-removed dental surface. In orthodontic process, ceramic bracket was repeated debonding physically, then the adhesive remained on the dental surface. The residual adhesive caused a lack of adhesive strength between dental and ceramic bracket. Since commonly used adhesive in orthodontics is translucent, residual adhesive is hard to be detected with conventional microscopes. Therefore, 1310 nm center wavelength swept-source OCT system based on laboratory customized image processing algorithm was used for the precise detection of residual adhesive on tooth surface. The algorithm separates residual adhesive from dental surface by comparing the height of adjacent B-scan images, while providing color-scaled images emphasizing the thickness information of residual adhesive. Finally, the acquired results were compared with microscopic and adhesive remnant index scoring gold standards, while the comparison confirmed the potential merits and the improvements of the proposed method over gold standards.
Collapse
Affiliation(s)
- Yoonseok Kim
- School of Electronic and Electrical Engineering, College of IT Engineering, Kyungpook National University, Daegu 41566, Korea; (Y.K.); (D.J.); (D.S.); (J.L.); (H.D.K.); (J.K.)
| | - Gu-In Jung
- Institute of Advanced Convergence Technology, Kyungpook National University, Daegu 41061, Korea; (G.-I.J.); (W.J.D.); (S.-M.K.); (J.H.L.); (J.H.H.)
| | - Deokmin Jeon
- School of Electronic and Electrical Engineering, College of IT Engineering, Kyungpook National University, Daegu 41566, Korea; (Y.K.); (D.J.); (D.S.); (J.L.); (H.D.K.); (J.K.)
| | - Ruchire Eranga Wijesinghe
- Department of Materials and Mechanical Technology, Faculty of Technology, University of Sri Jayewardenepura, Pitipana, Homagama 10200, Sri Lanka;
| | - Daewoon Seong
- School of Electronic and Electrical Engineering, College of IT Engineering, Kyungpook National University, Daegu 41566, Korea; (Y.K.); (D.J.); (D.S.); (J.L.); (H.D.K.); (J.K.)
| | - Jaeyul Lee
- School of Electronic and Electrical Engineering, College of IT Engineering, Kyungpook National University, Daegu 41566, Korea; (Y.K.); (D.J.); (D.S.); (J.L.); (H.D.K.); (J.K.)
| | - Woo Jong Do
- Institute of Advanced Convergence Technology, Kyungpook National University, Daegu 41061, Korea; (G.-I.J.); (W.J.D.); (S.-M.K.); (J.H.L.); (J.H.H.)
| | - Sung-Min Kwon
- Institute of Advanced Convergence Technology, Kyungpook National University, Daegu 41061, Korea; (G.-I.J.); (W.J.D.); (S.-M.K.); (J.H.L.); (J.H.H.)
| | - Jong Hoon Lee
- Institute of Advanced Convergence Technology, Kyungpook National University, Daegu 41061, Korea; (G.-I.J.); (W.J.D.); (S.-M.K.); (J.H.L.); (J.H.H.)
| | - Jun Ho Hwang
- Institute of Advanced Convergence Technology, Kyungpook National University, Daegu 41061, Korea; (G.-I.J.); (W.J.D.); (S.-M.K.); (J.H.L.); (J.H.H.)
| | - Hyun Deok Kim
- School of Electronic and Electrical Engineering, College of IT Engineering, Kyungpook National University, Daegu 41566, Korea; (Y.K.); (D.J.); (D.S.); (J.L.); (H.D.K.); (J.K.)
- Institute of Advanced Convergence Technology, Kyungpook National University, Daegu 41061, Korea; (G.-I.J.); (W.J.D.); (S.-M.K.); (J.H.L.); (J.H.H.)
| | - Kyu-Bok Lee
- Advanced Dental Device Development Institute, Kyungpook National University, Daegu 41940, Korea;
- Department of Prosthodontics, School of Dentistry, Kyungpook National University, Daegu 41940, Korea
| | - Mansik Jeon
- School of Electronic and Electrical Engineering, College of IT Engineering, Kyungpook National University, Daegu 41566, Korea; (Y.K.); (D.J.); (D.S.); (J.L.); (H.D.K.); (J.K.)
| | - Jeehyun Kim
- School of Electronic and Electrical Engineering, College of IT Engineering, Kyungpook National University, Daegu 41566, Korea; (Y.K.); (D.J.); (D.S.); (J.L.); (H.D.K.); (J.K.)
| |
Collapse
|
192
|
Shah S, Yu CN, Zheng M, Kim H, Eggleston MS. Microparticle-Based Biochemical Sensing Using Optical Coherence Tomography and Deep Learning. ACS NANO 2021; 15:9764-9774. [PMID: 33961739 DOI: 10.1021/acsnano.1c00497] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Advancing continuous health monitoring beyond vital signs to biochemistry will revolutionize personalized medicine. Herein, we report a biosensing platform to achieve remote biochemical monitoring using microparticle-based biosensors and optical coherence tomography (OCT). Stimuli-responsive, polymeric microparticles were designed to serve as freely dispersible biorecognition units, wherein binding with a target biochemical induces volumetric changes of the microparticle. Analytical approaches to detect these submicron changes in 3D using OCT were devised by modeling the microparticle as an optical cavity, enabling estimations far below the resolution of the OCT system. As a proof of concept, we demonstrated the 3D spatiotemporal monitoring of glucose-responsive microparticles distributed throughout a tissue mimic in response to dynamically fluctuating levels of glucose. Deep learning was further implemented using 3D convolutional neural networks to automate the vast processing of the continuous stream of three-dimensional time series data, resulting in a robust end-to-end pipeline with immense potential for continuous in vivo biochemical monitoring.
Collapse
Affiliation(s)
- Shreyas Shah
- Nokia Bell Labs, New Providence, New Jersey 07974 United States
| | - Chun-Nam Yu
- Nokia Bell Labs, New Providence, New Jersey 07974 United States
| | - Mingde Zheng
- Nokia Bell Labs, New Providence, New Jersey 07974 United States
| | - Heejong Kim
- Nokia Bell Labs, New Providence, New Jersey 07974 United States
| | | |
Collapse
|
193
|
Moody AS, Dayton PA, Zamboni WC. Imaging methods to evaluate tumor microenvironment factors affecting nanoparticle drug delivery and antitumor response. CANCER DRUG RESISTANCE (ALHAMBRA, CALIF.) 2021; 4:382-413. [PMID: 34796317 PMCID: PMC8597952 DOI: 10.20517/cdr.2020.94] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/15/2020] [Revised: 01/07/2021] [Accepted: 01/28/2021] [Indexed: 11/24/2022]
Abstract
Standard small molecule and nanoparticulate chemotherapies are used for cancer treatment; however, their effectiveness remains highly variable. One reason for this variable response is hypothesized to be due to nonspecific drug distribution and heterogeneity of the tumor microenvironment, which affect tumor delivery of the agents. Nanoparticle drugs have many theoretical advantages, but due to variability in tumor microenvironment (TME) factors, the overall drug delivery to tumors and associated antitumor response are low. The nanotechnology field would greatly benefit from a thorough analysis of the TME factors that create these physiological barriers to tumor delivery and treatment in preclinical models and in patients. Thus, there is a need to develop methods that can be used to reveal the content of the TME, determine how these TME factors affect drug delivery, and modulate TME factors to increase the tumor delivery and efficacy of nanoparticles. In this review, we will discuss TME factors involved in drug delivery, and how biomedical imaging tools can be used to evaluate tumor barriers and predict drug delivery to tumors and antitumor response.
Collapse
Affiliation(s)
- Amber S. Moody
- UNC Eshelman School of Pharmacy, University of North Carolina, Chapel Hill, NC 27599, USA
- UNC Lineberger Comprehensive Cancer Center, Chapel Hill, NC 27599, USA
- Carolina Institute for Nanomedicine, Chapel Hill, NC 27599, USA
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Chapel Hill, NC 27599, USA
| | - Paul A. Dayton
- UNC Eshelman School of Pharmacy, University of North Carolina, Chapel Hill, NC 27599, USA
- UNC Lineberger Comprehensive Cancer Center, Chapel Hill, NC 27599, USA
- Joint Department of Biomedical Engineering, University of North Carolina and North Carolina State University, Chapel Hill, NC 27599, USA
| | - William C. Zamboni
- UNC Eshelman School of Pharmacy, University of North Carolina, Chapel Hill, NC 27599, USA
- UNC Lineberger Comprehensive Cancer Center, Chapel Hill, NC 27599, USA
- Carolina Institute for Nanomedicine, Chapel Hill, NC 27599, USA
| |
Collapse
|
194
|
Abstract
Age-related macular degeneration (AMD) is a leading cause of blindness. The main risk factor is advancing age, with the severity of vision loss ranging from mild to severe. There is a 25% risk of early AMD and 8% risk of late AMD in patients over the age of 75, with the number of cases expected to increase because of the aging population. Diagnosis of the disease requires a dilated fundus examination. Physicians should be aware of the symptoms, risk factors, and treatment options for AMD to refer appropriately for ophthalmologic evaluation. Early detection can be helpful to prevent disease progression.
Collapse
Affiliation(s)
- Catherine J Thomas
- Department of Ophthalmology, Feinberg School of Medicine, Northwestern University, 645 North Michigan Avenue, Suite 440, Chicago, IL 60611, USA. https://twitter.com/SportsDoc2009
| | - Rukhsana G Mirza
- Department of Ophthalmology, Feinberg School of Medicine, Northwestern University, 645 North Michigan Avenue, Suite 440, Chicago, IL 60611, USA. https://twitter.com/SportsDoc2009
| | - Manjot K Gill
- Department of Ophthalmology, Feinberg School of Medicine, Northwestern University, 645 North Michigan Avenue, Suite 440, Chicago, IL 60611, USA.
| |
Collapse
|
195
|
Phan TL, Hieu NV, Li TS, Tsao KC, Ching CTS. Noninvasive and real-time in vivo characterization of Inflammation skin. A feasibility of animal study. Skin Res Technol 2021; 27:846-853. [PMID: 33890700 DOI: 10.1111/srt.13030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Accepted: 03/11/2021] [Indexed: 11/26/2022]
Abstract
BACKGROUND Inflammatory skin diseases were the most common problem in dermatology. This study aimed to develop a circuit by using a simple method for noninvasive, objective, and real-time skin inflammation screening. MATERIALS AND METHODS Sprague-Dawley rats were used in this study. The rats were chemically induced to suffer from skin inflammation at the back of their left-hand side while the right-hand side of their back remained untreated serving as a control. Impedance (Z) spectrum of the rat's skin was recorded. RESULTS Two characteristic frequencies (4.5 and 48.3 kHz) were found. At the two frequencies, the impedance of inflammatory skin tissue (ZIST ) was found to be significantly (P < .05) smaller than that of normal healthy skin tissue (ZNHST ). Moreover, the ratio of the impedance measured at 4.5 kHz (Zf = 4 .5 kHz ) to the impedance measured at 48.3 kHz (Zf = 48.3 kHz ), that is, Zf = 4.5 kHz /Zf = 48.3 kHz , was capable of skin inflammation screening. It was observed that the inflammatory skin tissue (IST) had the smaller value of Zf = 4 .5 kHz /Zf = 48.3 kHz (value < 8.5) and normal healthy skin tissue (NHST) had the higher value of Zf = 4 .5 kHz /Zf = 48.3 kHz (value ≈ 10) which almost remained constant. CONCLUSION A circuit was developed which was used for measuring the skin impedance accurately at the two characteristic frequencies for skin inflammation screening.
Collapse
Affiliation(s)
- Thien Luan Phan
- Graduate Institute of Biomedical Engineering, National Chung Hsing University, Taichung City, Taiwan.,Department of Physics and Electronic Engineering, University of Science (Vietnam National University of Hochiminh City), Ho Chi Minh City, Vietnam
| | - Nguyen Van Hieu
- Department of Physics and Electronic Engineering, University of Science (Vietnam National University of Hochiminh City), Ho Chi Minh City, Vietnam
| | - Tzong Shiun Li
- Department of Plastic Surgery, Show Chwan Memorial Hospital, Changhua, Taiwan
| | - Ko-Chang Tsao
- Department of Dermatology, Puli Christian Hospital, Puli, Taiwan
| | - Congo Tak Shing Ching
- Graduate Institute of Biomedical Engineering, National Chung Hsing University, Taichung City, Taiwan
| |
Collapse
|
196
|
Utilization potential of intraluminal optical coherence tomography for the Eustachian tube. Sci Rep 2021; 11:6219. [PMID: 33737591 PMCID: PMC7973536 DOI: 10.1038/s41598-021-85634-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2020] [Accepted: 03/02/2021] [Indexed: 12/17/2022] Open
Abstract
Imaging the Eustachian tube is challenging because of its complex anatomy and limited accessibility. This study fabricated a fiber-based optical coherence tomography (OCT) catheter and investigated its potential for assessing the Eustachian tube anatomy. A customized OCT system and an imaging catheter, termed the Eustachian OCT, were developed for visualizing the Eustachian tube. Three male swine cadaver heads were used to study OCT image acquisition and for subsequent histologic correlation. The imaging catheter was introduced through the nasopharyngeal opening and reached toward the middle ear. The OCT images were acquired from the superior to the nasopharyngeal opening before and after Eustachian tube balloon dilatation. The histological anatomy of the Eustachian tube was compared with corresponding OCT images, The new, Eustachian OCT catheter was successfully inserted in the tubal lumen without damage. Cross-sectional images of the tube were successfully obtained, and the margins of the anatomical structures including cartilage, mucosa lining, and fat could be successfully delineated. After balloon dilatation, the expansion of the cross-sectional area could be identified from the OCT images. Using the OCT technique to assess the Eustachian tube anatomy was shown to be feasible, and the fabricated OCT image catheter was determined to be suitable for Eustachian tube assessment.
Collapse
|
197
|
Osiac E, Mitran SI, Manea CN, Cojocaru A, Rosu G, Osiac M, Pirici DN, Bălșeanu AT, Cătălin B. Optical coherence tomography microscopy in experimental traumatic brain injury. Microsc Res Tech 2021; 84:422-431. [PMID: 33009699 PMCID: PMC7891427 DOI: 10.1002/jemt.23599] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2020] [Revised: 08/19/2020] [Accepted: 08/30/2020] [Indexed: 12/28/2022]
Abstract
Worldwide elderly traumatic brain injury (TBI) patients tend to become an increasing burden to the society. Thus, a faster and less expensive way of evaluating TBI victims is needed. In the present study we investigated if optical coherence tomography (OCT) could be used as such a method. By using an animal model, we established if OCT can detect cortical changes in the acute phase of a penetrating TBI, in young (5-7 months) and old (20-22 months) rats. Due to the long-term evolution of TBI's, we wanted to investigate to what extent OCT could detect changes within the cortex in the chronic phase. Adult (7-12 months) male rats were used. Surprisingly, OCT imaging of the normal hemisphere was able to discriminate age-related differences in the mean gray values (MGV) of recorded pixels (p = .032). Furthermore, in the acute phase of TBI, OCT images recorded at 24 hr after the injury showed differences between the apparent damaged area of young and aged animals. Changes of MGV and skewness were only recorded 48 hr after injury. Monitoring the chronical evolution of the TBI with OCT revealed changes over time exceeding the normal range recorded for MGV, skewness and kurtosis, 14 and 21 days after TBI. Although in the present study we still used an extremely invasive approach, as technology improves, less invasive and non-harmful ways of recording OCT may allow for an objective way to detect changes within the brain structure after brain injuries.
Collapse
Affiliation(s)
- Eugen Osiac
- Experimental Research Center for Normal and Pathological AgingUniversity of Medicine and Pharmacy of CraiovaCraiovaRomania
- Department of BiophysicsUniversity of Medicine and Pharmacy of CraiovaCraiovaRomania
| | - Smaranda Ioana Mitran
- Experimental Research Center for Normal and Pathological AgingUniversity of Medicine and Pharmacy of CraiovaCraiovaRomania
- Department of PhysiologyUniversity of Medicine and Pharmacy of CraiovaCraiovaRomania
| | - Cătălin Nicolae Manea
- Experimental Research Center for Normal and Pathological AgingUniversity of Medicine and Pharmacy of CraiovaCraiovaRomania
- Department of Informatics, Communication and StatisticsUniversity of Medicine and Pharmacy of CraiovaCraiovaRomania
| | - Alexandru Cojocaru
- Department of PhysiologyUniversity of Medicine and Pharmacy of CraiovaCraiovaRomania
| | - Gabriela‐Camelia Rosu
- Department of Research MethodologyUniversity of Medicine and Pharmacy of CraiovaCraiovaRomania
| | - Mariana Osiac
- Department of Physics, Faculty of ScienceUniversity of CraiovaCraiovaRomania
| | - Daniel Nicolae Pirici
- Department of Research MethodologyUniversity of Medicine and Pharmacy of CraiovaCraiovaRomania
| | - Adrian Tudor Bălșeanu
- Experimental Research Center for Normal and Pathological AgingUniversity of Medicine and Pharmacy of CraiovaCraiovaRomania
- Department of PhysiologyUniversity of Medicine and Pharmacy of CraiovaCraiovaRomania
| | - Bogdan Cătălin
- Experimental Research Center for Normal and Pathological AgingUniversity of Medicine and Pharmacy of CraiovaCraiovaRomania
- Department of PhysiologyUniversity of Medicine and Pharmacy of CraiovaCraiovaRomania
| |
Collapse
|
198
|
Utilisation of Chick Embryo Chorioallantoic Membrane as a Model Platform for Imaging-Navigated Biomedical Research. Cells 2021; 10:cells10020463. [PMID: 33671534 PMCID: PMC7926796 DOI: 10.3390/cells10020463] [Citation(s) in RCA: 41] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2021] [Revised: 02/15/2021] [Accepted: 02/19/2021] [Indexed: 02/07/2023] Open
Abstract
The fertilised chick egg and particularly its chorioallantoic membrane (CAM) have drawn continuing interest in biomedicine and bioengineering fields, especially for research on vascular study, cancer, drug screening and development, cell factors, stem cells, etc. This literature review systemically introduces the CAM's structural evolution, functions, vascular features and the circulation system, and cell regulatory factors. It also presents the major and updated applications of the CAM in assays for pharmacokinetics and biodistribution, drug efficacy and toxicology testing/screening in preclinical pharmacological research. The time course of CAM applications for different assays and their advantages and limitations are summarised. Among these applications, two aspects are emphasised: (1) potential utility of the CAM for preclinical studies on vascular-disrupting agents (VDAs), promising for anti-cancer vascular-targeted therapy, and (2) modern imaging technologies, including modalities and their applications for real-time visualisation, monitoring and evaluation of the changes in CAM vasculature as well as the interactions occurring after introducing the tested medical, pharmaceutical and biological agents into the system. The aim of this article is to help those working in the biomedical field to familiarise themselves with the chick embryo CAM as an alternative platform and to utilise it to design and optimise experimental settings for their specific research topics.
Collapse
|
199
|
Saleah SA, Seong D, Han S, Wijesinghe RE, Ravichandran NK, Jeon M, Kim J. Integrated Quad-Scanner Strategy-Based Optical Coherence Tomography for the Whole-Directional Volumetric Imaging of a Sample. SENSORS (BASEL, SWITZERLAND) 2021; 21:1305. [PMID: 33670358 PMCID: PMC7918791 DOI: 10.3390/s21041305] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/15/2021] [Revised: 02/07/2021] [Accepted: 02/08/2021] [Indexed: 01/01/2023]
Abstract
Whole-directional scanning methodology is required to observe distinctive features of an entire physical structure with a three dimensional (3D) visualization. However, the implementation of whole-directional scanning is challenging for conventional optical coherence tomography (OCT), which scans a limited portion of the sample by utilizing unidirectional and bidirectional scanning methods. Therefore, in this paper an integrated quad-scanner (QS) strategy-based OCT method was implemented to obtain the whole-directional volumetry of a sample by employing four scanning arms installed around the sample. The simultaneous and sequential image acquisition capabilities are the conceptual key points of the proposed QS-OCT method, and were implemented using four precisely aligned scanning arms and applied in a complementary way according to the experimental criteria. To assess the feasibility of obtaining whole-directional morphological structures, a roll of Scotch tape, an ex vivo mouse heart, and kidney specimens were imaged and independently obtained tissue images at different directions were delicately merged to compose the 3D volume data set. The results revealed the potential merits of QS-OCT-based whole-directional imaging, which can be a favorable inspection method for various discoveries that require the dynamic coordinates of the whole physical structure.
Collapse
Affiliation(s)
- Sm Abu Saleah
- School of Electronic and Electrical Engineering, College of IT Engineering, Kyungpook National University, 80, Daehak-ro, Buk-gu, Daegu 41566, Korea; (S.A.S.); (D.S.); (S.H.)
| | - Daewoon Seong
- School of Electronic and Electrical Engineering, College of IT Engineering, Kyungpook National University, 80, Daehak-ro, Buk-gu, Daegu 41566, Korea; (S.A.S.); (D.S.); (S.H.)
| | - Sangyeob Han
- School of Electronic and Electrical Engineering, College of IT Engineering, Kyungpook National University, 80, Daehak-ro, Buk-gu, Daegu 41566, Korea; (S.A.S.); (D.S.); (S.H.)
- Institute of Biomedical Engineering, School of Medicine, Kyungpook National University, 80, Daehak-ro, Buk-gu, Daegu 41566, Korea
| | - Ruchire Eranga Wijesinghe
- Department of Materials and Mechanical Technology, Faculty of Technology, University of Sri Jayewardenepura, Pitipana, Homagama 10200, Sri Lanka;
| | - Naresh Kumar Ravichandran
- Center for Scientific Instrumentation, Korea Basic Science Institute, 169-148, Gwahak-ro Yuseong-gu, Daejeon 34133, Korea;
| | - Mansik Jeon
- School of Electronic and Electrical Engineering, College of IT Engineering, Kyungpook National University, 80, Daehak-ro, Buk-gu, Daegu 41566, Korea; (S.A.S.); (D.S.); (S.H.)
| | - Jeehyun Kim
- School of Electronic and Electrical Engineering, College of IT Engineering, Kyungpook National University, 80, Daehak-ro, Buk-gu, Daegu 41566, Korea; (S.A.S.); (D.S.); (S.H.)
| |
Collapse
|
200
|
Adams W, Espicha T, Estipona J. Getting Your Neutrophil: Neutrophil Transepithelial Migration in the Lung. Infect Immun 2021; 89:IAI.00659-20. [PMID: 33526562 DOI: 10.1128/iai.00659-20] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Neutrophil transepithelial migration is a fundamental process that facilitates the rapid trafficking of neutrophils to inflammatory foci and occurs across a diverse range of tissues. For decades there has been widespread interest in understanding the mechanisms that drive this migratory process in response to different pathogens and organ systems. This has led to the successful integration of key findings on neutrophil transepithelial migration from the intestines, lungs, liver, genitourinary tract, and other tissues into a single, cohesive model. However, recent studies have identified organ specific differences in neutrophil transepithelial migration. These findings support a model where the tissue in concert with the pro-inflammatory stimuli dictate a unique collection of signals that drive neutrophil trafficking. This review focuses on the mechanisms that drive neutrophil transepithelial migration in response to microbial infection of a single organ, the lung. Herein we provide a detailed analysis of the adhesion molecules and chemoattractants that contribute to the recruitment of neutrophil into the airways. We also highlight important advances in experimental models for studying neutrophil transepithelial migration in the lung over the last decade.
Collapse
Affiliation(s)
- Walter Adams
- Department of Biological Sciences, San Jose State University, San Jose, CA 95192 USA
| | - Taylor Espicha
- Department of Biological Sciences, San Jose State University, San Jose, CA 95192 USA
| | - Janine Estipona
- Department of Biological Sciences, San Jose State University, San Jose, CA 95192 USA
| |
Collapse
|