1
|
Gong YXY, Huang XF, Liang J, Xie J, Qing LS. Aptamer-based microfluidics for the detection of cancer biomarkers. Anal Bioanal Chem 2025:10.1007/s00216-025-05863-7. [PMID: 40227354 DOI: 10.1007/s00216-025-05863-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2025] [Revised: 03/18/2025] [Accepted: 03/25/2025] [Indexed: 04/15/2025]
Abstract
Early diagnosis of cancer is a major concern in clinical medicine. Recently, aptamer-based microfluidics have offered promising platforms for the sensitive detection of cancer biomarkers. This review summarizes the application of aptamer sensors in the microfluidic platform for cancer biomarker analysis. The materials for microfluidic aptamer biosensor fabrication, unique design based on microposts, materials for enhanced detection capability, and the application principle of combining with other detection methods are introduced in detail, so as to demonstrate its development potential in cancer diagnosis and personalized therapy. Finally, the challenges and opportunities for developing miniaturized diagnostic platforms are discussed.
Collapse
Affiliation(s)
- Yi-Xin-Yue Gong
- School of Pharmacy, Chengdu Medical College, Chengdu, 610500, China
- Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, 610041, China
| | - Xiao-Feng Huang
- Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, 610041, China
| | - Jian Liang
- Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, 610041, China
| | - Jing Xie
- School of Pharmacy, Chengdu Medical College, Chengdu, 610500, China.
| | - Lin-Sen Qing
- Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, 610041, China.
| |
Collapse
|
2
|
Liu Y, Lao X, Wong MC, Song M, Zhao Y, Ma Y, Bai Q, Hao J. Intelligent Point-of-Care Biosensing Platform Based on Luminescent Nanoparticles and Microfluidic Biochip with Machine Vision Algorithm Analysis. NANO-MICRO LETTERS 2025; 17:215. [PMID: 40227357 PMCID: PMC11996743 DOI: 10.1007/s40820-025-01745-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/13/2025] [Accepted: 03/24/2025] [Indexed: 04/15/2025]
Abstract
Realizing the point-of-care tumor markers biodetection with good convenience and high sensitivity possesses great significance for prompting cancer monitoring and screening in biomedical study field. Herein, the quantum dots luminescence and microfluidic biochip with machine vision algorithm-based intelligent biosensing platform have been designed and manufactured for point-of-care tumor markers diagnostics. The employed quantum dots with excellent photoluminescent performance are modified with specific antibody as the optical labeling agents for the designed sandwich structure immunoassay. The corresponding biosensing investigations of the designed biodetection platform illustrate several advantages involving high sensitivity (~ 0.021 ng mL-1), outstanding accessibility, and great integrability. Moreover, related test results of human-sourced artificial saliva samples demonstrate better detection capabilities compared with commercially utilized rapid test strips. Combining these infusive abilities, our elaborate biosensing platform is expected to exhibit potential applications for the future point-of-care tumor markers diagnostic area.
Collapse
Affiliation(s)
- Yuan Liu
- Department of Applied Physics, The Hong Kong Polytechnic University, Kowloon, 999077, Hong Kong, People's Republic of China
| | - Xinyue Lao
- Department of Applied Physics, The Hong Kong Polytechnic University, Kowloon, 999077, Hong Kong, People's Republic of China
| | - Man-Chung Wong
- Department of Applied Physics, The Hong Kong Polytechnic University, Kowloon, 999077, Hong Kong, People's Republic of China
| | - Menglin Song
- Department of Applied Physics, The Hong Kong Polytechnic University, Kowloon, 999077, Hong Kong, People's Republic of China
| | - Yifei Zhao
- Department of Applied Physics, The Hong Kong Polytechnic University, Kowloon, 999077, Hong Kong, People's Republic of China
| | - Yingjin Ma
- Department of Applied Physics, The Hong Kong Polytechnic University, Kowloon, 999077, Hong Kong, People's Republic of China
| | - Qianqian Bai
- Department of Applied Physics, The Hong Kong Polytechnic University, Kowloon, 999077, Hong Kong, People's Republic of China
| | - Jianhua Hao
- Department of Applied Physics, The Hong Kong Polytechnic University, Kowloon, 999077, Hong Kong, People's Republic of China.
- Research Centre for Nanoscience and Nanotechnology, The Hong Kong Polytechnic University, Kowloon, 999077, Hong Kong, People's Republic of China.
| |
Collapse
|
3
|
Zhang H, Zhao L, Brodský J, Migliaccio L, Gablech I, Neužil P, You M. Proteomics-on-a-Chip - Microfluidics meets proteomics. Biosens Bioelectron 2025; 273:117122. [PMID: 39813764 DOI: 10.1016/j.bios.2024.117122] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2024] [Accepted: 12/30/2024] [Indexed: 01/18/2025]
Abstract
Proteomics provides an understanding of biological systems by enabling the detailed study of protein expression profiles, which is crucial for early disease diagnosis. Microfluidic-based proteomics enhances this field by integrating complex proteome analysis into compact and efficient systems. This review focuses on developing microfluidic chip structures for proteomics, covering on-chip sample pretreatment, protein extraction, purification, and identification in recent years. Furthermore, our work aims to inspire researchers to select proper methodologies in designing novel, efficient assays for proteomics applications by analyzing trends and innovations in this field.
Collapse
Affiliation(s)
- Haoqing Zhang
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, PR China; Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an, 710049, PR China; TFX Group-Xi'an Jiaotong University Institute of Life Health, Xi'an 710049, PR China
| | - Lei Zhao
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, PR China; Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an, 710049, PR China
| | - Jan Brodský
- Department of Microelectronics, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technická 3058/10, 616 00, Brno, Czech Republic
| | - Ludovico Migliaccio
- Department of Microelectronics, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technická 3058/10, 616 00, Brno, Czech Republic
| | - Imrich Gablech
- Department of Microelectronics, Faculty of Electrical Engineering and Communication, Brno University of Technology, Technická 3058/10, 616 00, Brno, Czech Republic
| | - Pavel Neužil
- Ministry of Education Key Laboratory of Micro and Nano Systems for Aerospace, School of Mechanical Engineering, Northwestern Polytechnical University, 127 West Youyi Road, Xi'an, Shaanxi, 710072, PR China.
| | - Minli You
- The Key Laboratory of Biomedical Information Engineering of the Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, PR China; Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an, 710049, PR China; TFX Group-Xi'an Jiaotong University Institute of Life Health, Xi'an 710049, PR China.
| |
Collapse
|
4
|
Han Y, Tian Y, Li Q, Yao T, Yao J, Zhang Z, Wu L. Advances in Detection Technologies for Pesticide Residues and Heavy Metals in Rice: A Comprehensive Review of Spectroscopy, Chromatography, and Biosensors. Foods 2025; 14:1070. [PMID: 40232082 PMCID: PMC11941943 DOI: 10.3390/foods14061070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2025] [Revised: 03/17/2025] [Accepted: 03/18/2025] [Indexed: 04/16/2025] Open
Abstract
Pesticide residues and heavy metals, originating from diverse sources such as agricultural practices and industrial activities, pose substantial risks to human health and the ecological environment. For instance, residues of organophosphorus pesticides may damage the human nervous system, while heavy metals such as mercury and cadmium accumulate in living organisms, potentially leading to severe organ damage. The contamination of rice with these pollutants has become a critical concern, necessitating the development of innovative detection techniques that are sensitive, accurate, rapid, portable, and intelligent. This review offers an in-depth analysis of the types, sources, health risks, and ecological impacts of pesticide residues and heavy metals in rice, providing a comprehensive understanding of the challenges and solutions associated with these contaminants. It further provides the fundamental principles, comparative advantages, and technical constraints of both conventional and emerging detection methodologies. These encompass traditional analytical techniques such as spectroscopy and chromatography, well-established immunoassay systems, as well as innovative biosensing technologies. This discussion is substantiated with representative case studies demonstrating their practical applications in rice quality assessment and safety testing. In addition, this review envisions future directions for the development of detection technologies, emphasizing the importance of miniaturization, multiplexed detection, integration with nanotechnology, and real-time monitoring systems. By providing a theoretical foundation for advancing food safety innovation, this review aims to contribute to the ongoing efforts to ensure rice quality and safety, protect public health, and preserve ecological balance.
Collapse
Affiliation(s)
- Yu Han
- Hubei Key Laboratory of Resource Utilization and Quality Control of Characteristic Crops, College of Life Science and Technology, Hubei Engineering University, Xiaogan 432000, China; (Y.H.); (Q.L.); (T.Y.); (J.Y.); (Z.Z.)
| | - Ye Tian
- Department of Biological Science and Technology, Wuhan Bioengineering Institute, Wuhan 430415, China;
| | - Qingqing Li
- Hubei Key Laboratory of Resource Utilization and Quality Control of Characteristic Crops, College of Life Science and Technology, Hubei Engineering University, Xiaogan 432000, China; (Y.H.); (Q.L.); (T.Y.); (J.Y.); (Z.Z.)
| | - Tianle Yao
- Hubei Key Laboratory of Resource Utilization and Quality Control of Characteristic Crops, College of Life Science and Technology, Hubei Engineering University, Xiaogan 432000, China; (Y.H.); (Q.L.); (T.Y.); (J.Y.); (Z.Z.)
| | - Jie Yao
- Hubei Key Laboratory of Resource Utilization and Quality Control of Characteristic Crops, College of Life Science and Technology, Hubei Engineering University, Xiaogan 432000, China; (Y.H.); (Q.L.); (T.Y.); (J.Y.); (Z.Z.)
| | - Zhengmao Zhang
- Hubei Key Laboratory of Resource Utilization and Quality Control of Characteristic Crops, College of Life Science and Technology, Hubei Engineering University, Xiaogan 432000, China; (Y.H.); (Q.L.); (T.Y.); (J.Y.); (Z.Z.)
- College of Food Science & Technology, Huazhong Agricultural University, Wuhan 430070, China
| | - Long Wu
- Key Laboratory of Tropical Fruits and Vegetables Quality and Safety, State Administration for Market Regulation, School of Food Science and Engineering, Hainan University, Haikou 570228, China
| |
Collapse
|
5
|
Tayyab M, Lin Z, Mahmoodi SR, Javanmard M. Automated Electrical Detection of Proteins for Oral Squamous Cell Carcinoma in an Integrated Microfluidic Chip Using Multi-Frequency Impedance Cytometry and Machine Learning. SENSORS (BASEL, SWITZERLAND) 2025; 25:1566. [PMID: 40096419 PMCID: PMC11902334 DOI: 10.3390/s25051566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2024] [Revised: 12/24/2024] [Accepted: 02/25/2025] [Indexed: 03/19/2025]
Abstract
Proteins can act as suitable biomarkers for the prognosis and diagnosis of certain conditions and can help us gain an understanding of the fundamental processes that occur inside an organism. In this work, we present a fully automated machine learning-assisted label-free method for the electrical detection of proteins in an integrated microfluidic chip using multi-frequency impedance cytometry and off-the-shelf components for realizing an automated and programmable fluid control system. We verify the robustness of our mixing method on our custom microfluidic mixer composed of polydimethylsiloxane (PDMS) serpentine channels optically using a fluorescent sandwich immunoassay and comparing the results with a commercial benchtop mixer. Salivary IL-6 is a biomarker for oral squamous cell carcinoma (OSCC), and we have demonstrated that our system can be used for the detection of quantification of Interleukin-6 (IL-6) levels in a solution using the impedance response of beads conjugated with the protein of interest, which passes through the microfluidic chip with reasonable accuracy (96%). Although we have demonstrated the detection and quantification of IL-6, our system can be adapted to any protein of interest with slight modification in the reagents and bead-binding protocols.
Collapse
Affiliation(s)
- Muhammad Tayyab
- Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ 08854, USA; (M.T.); (Z.L.)
| | - Zhongtian Lin
- Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ 08854, USA; (M.T.); (Z.L.)
| | - Seyed Reza Mahmoodi
- Department of Electrical and Computer Engineering, University of Denver, Denver, CO 80210, USA;
| | - Mehdi Javanmard
- Department of Electrical and Computer Engineering, Rutgers University, Piscataway, NJ 08854, USA; (M.T.); (Z.L.)
| |
Collapse
|
6
|
Dong W, Fu R, Zhang N, Zhao J, Ma Y, Cui H, Zhang J, Zhao Z, Li H, Zhao Y, Lu Y, Chen Z, Xu T, Xie H, Yu Q, Zhang S. Digital microfluidics with integrated Raman sensor for high-sensitivity in-situ bioanalysis. Biosens Bioelectron 2025; 271:117036. [PMID: 39657552 DOI: 10.1016/j.bios.2024.117036] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2024] [Revised: 11/13/2024] [Accepted: 12/03/2024] [Indexed: 12/12/2024]
Abstract
This study introduces an advanced bioanalytical platform that combines digital microfluidics (DMF) with Raman spectroscopy, effectively addressing common issues in bioanalysis such as sample contamination, excessive consumption of samples and reagents, and manual handling. Our innovative system is engineered to handle diverse sample types and enables both sample preparation and in-situ analysis on a single device, utilizing less than 5 μL of samples and reagents. It incorporates a Translucent Raman Enhancement Stack (TRES) sensor, which boosts the detection signal, and includes droplet-driving functionality for automated processing of complex samples in a compact setting. The hydrophilic surface of the TRES sensor draws analytes into the detection zone, expediting sample attachment and enhancing the surface-enhanced Raman scattering (SERS). Moreover, the TRES sensors are cost-effective, straightforward to manufacture, and scalable, making them suitable for widespread production and single-use bioanalytical applications. This integrated and automated approach streamlines the sample preparation and analysis processes, enhances detection efficiency, and achieves high sensitivity, excellent linearity, and effective detection of different biochemical analytes. We validate the system's accuracy through on-device enrichment and analysis of exosomes from serum, demonstrating its capability for real-time, on-site analysis of complex biological samples.
Collapse
Affiliation(s)
- Wenbo Dong
- Beijing Advanced Innovation Center for Intelligent Robots and Systems, School of Mechanical Engineering, Beijing Institute of Technology, Beijing, 100081, PR China
| | - Rongxin Fu
- School of Medical Technology, Beijing Institute of Technology, Beijing, 100081, PR China; Chongqing Institute of Microelectronics and Microsystems, Beijing Institute of Technology, Beijing, 100081, PR China.
| | - Nan Zhang
- School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, PR China
| | - Jing Zhao
- Beijing Advanced Innovation Center for Intelligent Robots and Systems, School of Mechanical Engineering, Beijing Institute of Technology, Beijing, 100081, PR China
| | - Yudan Ma
- School of Medical Technology, Beijing Institute of Technology, Beijing, 100081, PR China
| | - Han Cui
- School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, PR China
| | - Jiangjiang Zhang
- School of Life Science, Beijing Institute of Technology, Beijing, 100081, PR China
| | - Zipeng Zhao
- School of Materials Science and Engineering, Beijing Institute of Technology, Beijing, 100081, PR China
| | - Hang Li
- School of Medical Technology, Beijing Institute of Technology, Beijing, 100081, PR China; Chongqing Institute of Microelectronics and Microsystems, Beijing Institute of Technology, Beijing, 100081, PR China
| | - Yunxia Zhao
- School of Optics and Photonics, Beijing Institute of Technology, Beijing, 100081, PR China
| | - Yao Lu
- Chongqing Institute of Microelectronics and Microsystems, Beijing Institute of Technology, Beijing, 100081, PR China; Engineering Research Center of Integrated Acousto-opto-electronic Microsystems (Ministry of Education of China), School of Integrated Circuits and Electronics, Beijing Institute of Technology, Beijing, 1000815, PR China
| | - Zhizhong Chen
- School of Physics, Peking University, Beijing, 100084, PR China
| | - Tianming Xu
- Department of Gastroenterology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Peking Union Medical College, Beijing, 100730, PR China
| | - Huikai Xie
- Chongqing Institute of Microelectronics and Microsystems, Beijing Institute of Technology, Beijing, 100081, PR China; Engineering Research Center of Integrated Acousto-opto-electronic Microsystems (Ministry of Education of China), School of Integrated Circuits and Electronics, Beijing Institute of Technology, Beijing, 1000815, PR China
| | - Qian Yu
- School of Mechanical Engineering, Beijing Institute of Technology, Beijing, 100081, PR China
| | - Shuailong Zhang
- Beijing Advanced Innovation Center for Intelligent Robots and Systems, School of Mechanical Engineering, Beijing Institute of Technology, Beijing, 100081, PR China; Chongqing Institute of Microelectronics and Microsystems, Beijing Institute of Technology, Beijing, 100081, PR China; Engineering Research Center of Integrated Acousto-opto-electronic Microsystems (Ministry of Education of China), School of Integrated Circuits and Electronics, Beijing Institute of Technology, Beijing, 1000815, PR China.
| |
Collapse
|
7
|
Burčík D, Macko J, Podrojková N, Demeterová J, Stano M, Oriňak A. Role of Cell Adhesion in Cancer Metastasis Formation: A Review. ACS OMEGA 2025; 10:5193-5213. [PMID: 39989825 PMCID: PMC11840620 DOI: 10.1021/acsomega.4c08140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/09/2024] [Revised: 01/10/2025] [Accepted: 01/22/2025] [Indexed: 02/25/2025]
Abstract
Intercellular adhesion is accompanied by several physical quantities and actions. In this review, we tried to collect information about the influence of surface energy and its impact on cell-cell adhesion. It still undergoes development for cancer treatment. Data on receptor-ligand interactions that occur on circulating tumor cells (CTCs) are described, and adhesion receptors as therapeutic targets are collected. Additionally, the impact of surface roughness on the interactions between CTC cells and the surface was monitored. The effects of different cell adhesion molecules (CAMs) on cell adhesion, growth, and proliferation were investigated. This review offers general principles of cell adhesion, through the blockade of adhesion with blocking drugs and inhibitors like computational models that describe the process of adhesion. Some theoretical models based on the minimum of the total free energy of interaction between CAMs and selected organic molecules have been presented. The final aim was to find information on how modulation of the surface of CTCs (by medicals or physically) inhibits cancer metastases formation.
Collapse
Affiliation(s)
- Denis Burčík
- University of P. J. Safarik
in Kosice, Faculty of Sciences,
Institute of Chemistry, Department of Physical Chemistry, Moyzesova 11, 041 01 Kosice, Slovakia
| | - Ján Macko
- University of P. J. Safarik
in Kosice, Faculty of Sciences,
Institute of Chemistry, Department of Physical Chemistry, Moyzesova 11, 041 01 Kosice, Slovakia
| | - Natália Podrojková
- University of P. J. Safarik
in Kosice, Faculty of Sciences,
Institute of Chemistry, Department of Physical Chemistry, Moyzesova 11, 041 01 Kosice, Slovakia
| | - Jana Demeterová
- University of P. J. Safarik
in Kosice, Faculty of Sciences,
Institute of Chemistry, Department of Physical Chemistry, Moyzesova 11, 041 01 Kosice, Slovakia
| | - Michal Stano
- University of P. J. Safarik
in Kosice, Faculty of Sciences,
Institute of Chemistry, Department of Physical Chemistry, Moyzesova 11, 041 01 Kosice, Slovakia
| | - Andrej Oriňak
- University of P. J. Safarik
in Kosice, Faculty of Sciences,
Institute of Chemistry, Department of Physical Chemistry, Moyzesova 11, 041 01 Kosice, Slovakia
| |
Collapse
|
8
|
Yang C, He C, Zhuo H, Wang J, Yong T, Gan L, Yang X, Nie L, Xi S, Liu Z, Liao G, Shi T. Cost-effective microfluidic flow cytometry for precise and gentle cell sorting. LAB ON A CHIP 2025; 25:698-713. [PMID: 39895391 DOI: 10.1039/d4lc00900b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/04/2025]
Abstract
Microfluidic flow cytometry (MFCM) is considered to be an effective substitute for traditional flow cytometry, because of its advantages in terms of higher integration, smaller device size, lower cost, and higher cell sorting activity. However, MFCM still faces challenges in balancing parameters such as sorting throughput, viability, sorting efficiency, and cost. Here, we demonstrate a cost-effective and high-performance microfluidic cytometry cell sorting system, along with a customized microfluidic chip that integrates hydrodynamic focusing, droplet encapsulation, and sorting for precise cell manipulation. An innovative photon incremental counting-based fluorescence detection method is proposed, which requires only one-fiftieth of the data compared to traditional methods. This significantly simplifies the structure of the system and substantially reduces costs. The system exhibits detection recoveries exceeding 95% across sample solution flow rates ranging from 10 to 80 μL min-1. Moreover, it accurately achieves individual droplet deflections at a droplet generation frequency of 1600 Hz. Ultimately, our cell sorting system offers an impressive sorting efficiency of 90.7% and a high cell viability of 94.3% when operating at a droplet generation frequency of 1316 Hz, highlighting its accuracy and gentleness throughout the entire process. Our work will enhance advances in the life sciences, thereby creating a boom in great applications in single-cell cloning, single-cell analysis, drug screening, etc.
Collapse
Affiliation(s)
- Canfeng Yang
- State Key Laboratory of Digital Manufacturing Equipment and Technology, School of Mechanical Science & Engineering, Huazhong University of Science and Technology, Wuhan 430074, China.
| | - Chunhua He
- State Key Laboratory of Digital Manufacturing Equipment and Technology, School of Mechanical Science & Engineering, Huazhong University of Science and Technology, Wuhan 430074, China.
| | - Huasheng Zhuo
- State Key Laboratory of Digital Manufacturing Equipment and Technology, School of Mechanical Science & Engineering, Huazhong University of Science and Technology, Wuhan 430074, China.
| | - Jianxin Wang
- State Key Laboratory of Digital Manufacturing Equipment and Technology, School of Mechanical Science & Engineering, Huazhong University of Science and Technology, Wuhan 430074, China.
| | - Tuying Yong
- National Engineering Research Center for Nanomedicine, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Lu Gan
- National Engineering Research Center for Nanomedicine, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Xiangliang Yang
- National Engineering Research Center for Nanomedicine, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Lei Nie
- School of Mechanical Engineering, Hubei University of Technology, Wuhan 430068, China
| | - Shuang Xi
- College of Mechanical and Electronic Engineering, Nanjing Forestry University, Nanjing, 210037, China
| | - Zhiyong Liu
- State Key Laboratory of Digital Manufacturing Equipment and Technology, School of Mechanical Science & Engineering, Huazhong University of Science and Technology, Wuhan 430074, China.
| | - Guanglan Liao
- State Key Laboratory of Digital Manufacturing Equipment and Technology, School of Mechanical Science & Engineering, Huazhong University of Science and Technology, Wuhan 430074, China.
| | - Tielin Shi
- State Key Laboratory of Digital Manufacturing Equipment and Technology, School of Mechanical Science & Engineering, Huazhong University of Science and Technology, Wuhan 430074, China.
| |
Collapse
|
9
|
De Figueiredo I, Bartenlian B, Hamouda F, Bouville D, Pallandre A, Halgand F. From Microsize Chromatographic Manufacturing for Fast Desalting to Its Characterization. Anal Chem 2024; 96:15907-15914. [PMID: 39344030 DOI: 10.1021/acs.analchem.4c02568] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/01/2024]
Abstract
Microfluidic devices are becoming increasingly popular in protein analysis due to their ability to reduce sample and buffer volumes. However, there is a research gap concerning the coupling of this technology with ion mobility and mass spectrometry (IM-MS). This study aims to fill this void by introducing the manufacture and the characterization of a microsize exclusion chromatography (μSEC) module for fast desalting and its integration into microfluidics, along with its coupling to electrospray ionization and ion mobility mass spectrometry (ESI-IM-MS). To assess the feasibility of this approach, the desalting of α-synuclein (αS) was investigated using Bio Spin P6 gel as a stationary phase in the manufacture of a microfluidic device. αS detection by MS gives insight into the sample purity, while IM combined with MS provides information about protein structure. IM allowed both the recording of qualitative and quantitative information. The qualitative data provided a map of the conformers in equilibrium, while the calculation of the respective abundances (quantitative profile) of the conformers afforded the opportunity to describe the dynamics of the system. Our experiments, serving as proof-of-concept, demonstrate αS desalting, exchange buffer efficiency, and reduced solvent usage, without compromising the protein's structure.
Collapse
Affiliation(s)
- Isabel De Figueiredo
- Institut de Chimie Physique, Université Paris Saclay, bâtiment 349, 91400 Orsay, France
| | - Bernard Bartenlian
- Centre des nanosciences et nanotechnologies (C2N), 10 Bd Thomas Gobert, 91120 Palaiseau, France
| | - Frédéric Hamouda
- Centre des nanosciences et nanotechnologies (C2N), 10 Bd Thomas Gobert, 91120 Palaiseau, France
| | - David Bouville
- Centre des nanosciences et nanotechnologies (C2N), 10 Bd Thomas Gobert, 91120 Palaiseau, France
| | - Antoine Pallandre
- Institut de Chimie Physique, Université Paris Saclay, bâtiment 349, 91400 Orsay, France
| | - Frédéric Halgand
- Institut de Chimie Physique, Université Paris Saclay, bâtiment 349, 91400 Orsay, France
| |
Collapse
|
10
|
Roman J, Ge S, Bouaraphan S, Fink M, Trausch JJ, Verch T. Use of a Microfluidic Platform To Evaluate and Predict Reagent Performance in Microtiter Plate-Based Immunoassays. Anal Chem 2024; 96:3489-3497. [PMID: 38349730 DOI: 10.1021/acs.analchem.3c05278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/28/2024]
Abstract
Selection and characterization of antibodies are critically important in establishing robust immunoassays to support the development efforts of vaccines. Plate-based ELISA can be time- and resource-intensive to select initial antibody clones or characterize downstream resupply lots while providing limited information regarding the binding characteristics of the antibodies beyond concentration-response curves. This work applied the microfluidic Gyrolab to holistically evaluate immunoassay reagents through analyses of concentration-response curves as well as antibody-antigen interactions visualized in column images and affinity estimates. We exploited the automation capability of the Gyrolab to reduce the resources (time, reagents, and scientists) required for screening and evaluating antibody reagents. Using a flexible semi-universal assay format, we compared antibody clones for selection and resupply lots of sera and monoclonal antibodies in a simple "plug-and-play" manner without antibody modifications. We found that the performance of antibodies in the Gyrolab correlated well with the trends observed in traditional ELISAs, while the Gyrolab provided additional advantages over plate-based assays such as column images of antibody binding and affinity measurements.
Collapse
Affiliation(s)
- Jeanette Roman
- Merck & Co., Inc., West Point, Pennsylvania 19486, United States
| | - Shencheng Ge
- Merck & Co., Inc., West Point, Pennsylvania 19486, United States
| | | | - Malorie Fink
- Merck & Co., Inc., West Point, Pennsylvania 19486, United States
| | | | - Thorsten Verch
- Merck & Co., Inc., West Point, Pennsylvania 19486, United States
| |
Collapse
|
11
|
Wang S, Zhou Y, Li Z. A microfluidic cover converts a standard 96-well plate into a mass-transport-controlled immunoassay system. BIOMICROFLUIDICS 2024; 18:014102. [PMID: 38249129 PMCID: PMC10798817 DOI: 10.1063/5.0183651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Accepted: 01/01/2024] [Indexed: 01/23/2024]
Abstract
96-well microtiter plates, widely used in immunoassays, face challenges such as prolonged assay time and limited sensitivity due to the lack of analyte transport control. Orbital shakers, commonly employed to facilitate mass transport, offer limited improvements and can introduce assay inconsistencies. While microfluidic devices offer performance enhancements, their complexity and incompatibility with existing platforms limit their wide adoption. This study introduces a novel microfluidic 96-well cover designed to convert a standard 96-well plate to a mass-transport-controlled surface bioreactor. The cover employs microfluidic methods to enhance the diffusion flux of analytes toward the receptors immobilized on the well bottom. Both simulation and experimental results demonstrated that the cover significantly enhances the capture rate of analyte molecules, resulting in increased signal strength for various detection methods and a lower detection limit. The cover serves as an effective add-on to standard 96-well plates, offering enhanced assay performance without requiring modifications to existing infrastructure or reagents. This innovation holds promise for improving the efficiency and reliability of microtiter plate based immunoassays.
Collapse
Affiliation(s)
- Sheng Wang
- Department of Biomedical Engineering, The George Washington University, District of Columbia, 20052, USA
| | - You Zhou
- Department of Electrical and Computer Engineering, The George Washington University, District of Columbia, 20052, USA
| | - Zhenyu Li
- Department of Biomedical Engineering, The George Washington University, District of Columbia, 20052, USA
| |
Collapse
|
12
|
Farka Z, Brandmeier JC, Mickert MJ, Pastucha M, Lacina K, Skládal P, Soukka T, Gorris HH. Nanoparticle-Based Bioaffinity Assays: From the Research Laboratory to the Market. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2307653. [PMID: 38039956 DOI: 10.1002/adma.202307653] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 11/16/2023] [Indexed: 12/03/2023]
Abstract
Advances in the development of new biorecognition elements, nanoparticle-based labels as well as instrumentation have inspired the design of new bioaffinity assays. This review critically discusses the potential of nanoparticles to replace current enzymatic or molecular labels in immunoassays and other bioaffinity assays. Successful implementations of nanoparticles in commercial assays and the need for rapid tests incorporating nanoparticles in different roles such as capture support, signal generation elements, and signal amplification systems are highlighted. The limited number of nanoparticles applied in current commercial assays can be explained by challenges associated with the analysis of real samples (e.g., blood, urine, or nasal swabs) that are difficult to resolve, particularly if the same performance can be achieved more easily by conventional labels. Lateral flow assays that are based on the visual detection of the red-colored line formed by colloidal gold are a notable exception, exemplified by SARS-CoV-2 rapid antigen tests that have moved from initial laboratory testing to widespread market adaption in less than two years.
Collapse
Affiliation(s)
- Zdeněk Farka
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic
| | - Julian C Brandmeier
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Universitätsstr. 31, 93053, Regensburg, Germany
| | | | - Matěj Pastucha
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic
- TestLine Clinical Diagnostics, Křižíkova 188, Brno, 612 00, Czech Republic
| | - Karel Lacina
- CEITEC-Central European Institute of Technology, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic
| | - Petr Skládal
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic
| | - Tero Soukka
- Department of Life Technologies/Biotechnology, University of Turku, Kiinamyllynkatu 10, Turku, 20520, Finland
| | - Hans H Gorris
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic
| |
Collapse
|
13
|
Zhao Q, Wang J, Liu HB, Duan LH. Rhodamine derivative-functionalized mesoporous silica-Al 3+ hybrid material for fluorescence "turn-on" detection of tetracycline antibiotics in aqueous media. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2023; 302:123068. [PMID: 37393676 DOI: 10.1016/j.saa.2023.123068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2023] [Revised: 06/15/2023] [Accepted: 06/20/2023] [Indexed: 07/04/2023]
Abstract
The organic-inorganic hybrid material was prepared by embedding 2-amino-3',6'-bis(diethylamino)spiro[isoindoline-1,9'-xanthen]-3-one (RBH) onto mesoporous SBA-15 silica and coordinating it with Al3+ (RBH-SBA-15-Al3+). RBH-SBA-15-Al3+ was used for the selective and sensitive detection of tetracycline antibiotics (TAs) in aqueous media based on the binding site-signaling unit mechanism, in which Al3+ acted as the binding site and the fluorescence intensity at 586 nm as the response signal. The addition of TAs to RBH-SBA-15-Al3+ suspensions resulted in the formation of RBH-SBA-15-Al3+-TAs conjugates, which realized the electron transfer process and turned-on fluorescence signal at 586 nm. The detection limits for tetracycline (TC), oxytetracycline, and chlortetracycline were 0.06, 0.06, and 0.03 µM, respectively. Meanwhile, the detection of TC was feasible in real samples, such as tap water and honey. In addition, RBH-SBA-15 can operate as a TRANSFER logic gate by using Al3+ and TAs as input signals and the fluorescence intensity at 586 nm as output signal. This study proposes an efficient strategy for the selective detection of target analytes by introducing interaction sites (e.g. Al3+) with target analytes in the system.
Collapse
Affiliation(s)
- Qian Zhao
- School of Chemistry and Chemical Engineering, Guangxi University, Nanning 530004, PR China
| | - Jing Wang
- School of Chemistry and Chemical Engineering, Guangxi University, Nanning 530004, PR China.
| | - Hai-Bo Liu
- School of Chemistry and Chemical Engineering, Guangxi University, Nanning 530004, PR China
| | - Long-Hui Duan
- School of Chemistry and Chemical Engineering, Guangxi University, Nanning 530004, PR China
| |
Collapse
|
14
|
Hiniduma K, Bhalerao KS, De Silva PIT, Chen T, Rusling JF. Design and Fabrication of a 3D-Printed Microfluidic Immunoarray for Ultrasensitive Multiplexed Protein Detection. MICROMACHINES 2023; 14:2187. [PMID: 38138356 PMCID: PMC10745552 DOI: 10.3390/mi14122187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/27/2023] [Revised: 11/22/2023] [Accepted: 11/23/2023] [Indexed: 12/24/2023]
Abstract
Microfluidic technology has revolutionized device fabrication by merging principles of fluid dynamics with technologies from chemistry, physics, biology, material science, and microelectronics. Microfluidic systems manipulate small volumes of fluids to perform automated tasks with applications ranging from chemical syntheses to biomedical diagnostics. The advent of low-cost 3D printers has revolutionized the development of microfluidic systems. For measuring molecules, 3D printing offers cost-effective, time, and ease-of-designing benefits. In this paper, we present a comprehensive tutorial for design, optimization, and validation for creating a 3D-printed microfluidic immunoarray for ultrasensitive detection of multiple protein biomarkers. The target is the development of a point of care array to determine five protein biomarkers for aggressive cancers. The design phase involves defining dimensions of microchannels, reagent chambers, detection wells, and optimizing parameters and detection methods. In this study, the physical design of the array underwent multiple iterations to optimize key features, such as developing open detection wells for uniform signal distribution and a flap for covering wells during the assay. Then, full signal optimization for sensitivity and limit of detection (LOD) was performed, and calibration plots were generated to assess linear dynamic ranges and LODs. Varying characteristics among biomarkers highlighted the need for tailored assay conditions. Spike-recovery studies confirmed the assay's accuracy. Overall, this paper showcases the methodology, rigor, and innovation involved in designing a 3D-printed microfluidic immunoarray. Optimized parameters, calibration equations, and sensitivity and accuracy data contribute valuable metrics for future applications in biomarker analyses.
Collapse
Affiliation(s)
- Keshani Hiniduma
- Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060, USA; (K.H.); (K.S.B.); (P.I.T.D.S.); (T.C.)
| | - Ketki S. Bhalerao
- Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060, USA; (K.H.); (K.S.B.); (P.I.T.D.S.); (T.C.)
| | - Peyahandi I. Thilini De Silva
- Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060, USA; (K.H.); (K.S.B.); (P.I.T.D.S.); (T.C.)
| | - Tianqi Chen
- Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060, USA; (K.H.); (K.S.B.); (P.I.T.D.S.); (T.C.)
| | - James F. Rusling
- Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060, USA; (K.H.); (K.S.B.); (P.I.T.D.S.); (T.C.)
- Institute of Materials Science, University of Connecticut, Storrs, CT 06269-3136, USA
- Department of Surgery and Neag Cancer Center, Uconn Health, Farmington, CT 06030-0001, USA
- School of Chemistry, National University of Ireland at Galway, H91 TK33 Galway, Ireland
| |
Collapse
|
15
|
Qasim F, Ashraf MW, Tayyaba S, Tariq MI, Herrera-May AL. Simulation, Fabrication and Microfiltration Using Dual Anodic Aluminum Oxide Membrane. MEMBRANES 2023; 13:825. [PMID: 37887997 PMCID: PMC10608613 DOI: 10.3390/membranes13100825] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Revised: 10/03/2023] [Accepted: 10/06/2023] [Indexed: 10/28/2023]
Abstract
Microfluidic devices have gained subsequent attention due to their controlled manipulation of fluid for various biomedical applications. These devices can be used to study the behavior of fluid under several micrometer ranges within the channel. The major applications are the filtration of fluid, blood filtration and bio-medical analysis. For the filtration of water, as well as other liquids, the micro-filtration based microfluidic devices are considered as potential candidates to fulfill the desired conditions and requirements. The micro pore membrane can be designed and fabricated in such a way that it maximizes the removal of impurities from fluid. The low-cost micro-filtration method has been reported to provide clean fluid for biomedical applications and other purposes. In the work, anodic-aluminum-oxide-based membranes have been fabricated with different pore sizes ranging from 70 to 500 nm. A soft computing technique like fuzzy logic has been used to estimate the filtration parameters. Then, the finite-element-based analysis system software has been used to study the fluid flow through the double membrane. Then, filtration is performed by using a dual membrane and the clogging of the membrane has been studied after different filtration cycles using characterization like a scanning electron microscope. The filtration has been done to purify the contaminated fluid which has impurities like bacteria and protozoans. The membranes have been tested after each cycle to verify the results. The decrease in permeance with respect to the increase in the velocity of the fluid and the permeate volume per unit clearly depicts the removal of containments from the fluid after four and eight cycles of filtration. The results clearly show that the filtration efficiency can be improved by increasing the number of cycles and adding a dual membrane in the micro-fluidic device. The results show the potential of dual anodic aluminum oxide membranes for the effective filtration of fluids for biomedical applications, thereby offering a promising solution to address current challenges.
Collapse
Affiliation(s)
- Faheem Qasim
- Department of Electronics, Institute of Physics, GC University Lahore, Lahore 54000, Pakistan
| | - Muhammad Waseem Ashraf
- Department of Electronics, Institute of Physics, GC University Lahore, Lahore 54000, Pakistan
| | - Shahzadi Tayyaba
- Department of Information Sciences, Division of Science and Technology, Township Campus, University of Education, Lahore 54000, Pakistan;
| | - Muhammad Imran Tariq
- Department of Computer Science, Superior University Lahore, Lahore 54000, Pakistan;
| | - Agustín L. Herrera-May
- Micro and Nanotechnology Research Center, Universidad Veracruzana, Boca del Río 94294, Veracruz, Mexico;
| |
Collapse
|
16
|
Akbari Z, Raoufi MA, Mirjalali S, Aghajanloo B. A review on inertial microfluidic fabrication methods. BIOMICROFLUIDICS 2023; 17:051504. [PMID: 37869745 PMCID: PMC10589053 DOI: 10.1063/5.0163970] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/20/2023] [Accepted: 10/02/2023] [Indexed: 10/24/2023]
Abstract
In recent decades, there has been significant interest in inertial microfluidics due to its high throughput, ease of fabrication, and no need for external forces. The focusing efficiency of inertial microfluidic systems relies entirely on the geometrical features of microchannels because hydrodynamic forces (inertial lift forces and Dean drag forces) are the main driving forces in inertial microfluidic devices. In the past few years, novel microchannel structures have been propounded to improve particle manipulation efficiency. However, the fabrication of these unconventional structures has remained a serious challenge. Although researchers have pushed forward the frontiers of microfabrication technologies, the fabrication techniques employed for inertial microfluidics have not been discussed comprehensively. This review introduces the microfabrication approaches used for creating inertial microchannels, including photolithography, xurography, laser cutting, micromachining, microwire technique, etching, hot embossing, 3D printing, and injection molding. The advantages and disadvantages of these methods have also been discussed. Then, the techniques are reviewed regarding resolution, structures, cost, and materials. This review provides a thorough insight into the manufacturing methods of inertial microchannels, which could be helpful for future studies to improve the harvesting yield and resolution by choosing a proper fabrication technique.
Collapse
Affiliation(s)
- Zohreh Akbari
- Department of Mechanical Engineering, Ferdowsi University of Mashhad, Mashhad, Iran
| | | | - Sheyda Mirjalali
- School of Engineering, Macquarie University, Sydney, New South Wales, Australia
| | - Behrouz Aghajanloo
- School of Engineering, Macquarie University, Sydney, New South Wales, Australia
| |
Collapse
|
17
|
Qian C, Wan C, Li S, Xiao Y, Yuan H, Gao S, Wu L, Zhou M, Feng X, Li Y, Chen P, Liu BF. On-Line Dual-Active Valves Based Centrifugal Microfluidic Chip for Fully Automated Point-of-Care Immunoassay. Anal Chem 2023; 95:12521-12531. [PMID: 37556853 DOI: 10.1021/acs.analchem.3c02564] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/11/2023]
Abstract
There remains an unmet need for a fully integrated microfluidic platform that can automatically perform multistep and multireagent immunoassays. Here, we proposed a novel online dual-active valve-based centrifugal microfluidic chip, termed DAVM, for fully automatic point-of-care immunoassay. Practically, the puncture valve, one of the dual active valves, is capable of achieving precise, on-demand, sequential release of prestored reagents, while the other valve-reversible active valve enables controlled retention and drainage of the reaction solutions. Thereby, our technology mitigates the challenges of hydrophilic/hydrophobic modifications and unstable valve control performance commonly observed in passive valve controls. As a proof of concept, the indirect enzymatic immunoblotting technique was employed on DAVM for fully automated immunological analysis of eight targets, yielding outcomes within an hour. Furthermore, we conducted a comparative analysis of 28 clinical samples with autoimmune diseases. According to 224 clinical data, the sample testing concordance rate between DAVM and the traditional instrument was 82%, with a target compliance rate of 97%. Therefore, our DAVM system has powerful potential for fully automated immunoassays.
Collapse
Affiliation(s)
- Chungen Qian
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Chao Wan
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Shunji Li
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Yujin Xiao
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Huijuan Yuan
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Siyu Gao
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Liqiang Wu
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Mengfan Zhou
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Xiaojun Feng
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Yiwei Li
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Peng Chen
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| | - Bi-Feng Liu
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics-Hubei Bioinformatics and Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, 430074, China
| |
Collapse
|
18
|
Jiang Z, Zhuang Y, Guo S, Sohan ASMMF, Yin B. Advances in Microfluidics Techniques for Rapid Detection of Pesticide Residues in Food. Foods 2023; 12:2868. [PMID: 37569137 PMCID: PMC10417549 DOI: 10.3390/foods12152868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 07/24/2023] [Accepted: 07/26/2023] [Indexed: 08/13/2023] Open
Abstract
Food safety is a significant issue that affects people worldwide and is tied to their lives and health. The issue of pesticide residues in food is just one of many issues related to food safety, which leave residues in crops and are transferred through the food chain to human consumption. Foods contaminated with pesticide residues pose a serious risk to human health, including carcinogenicity, neurotoxicity, and endocrine disruption. Although traditional methods, including gas chromatography, high-performance liquid chromatography, chromatography, and mass spectrometry, can be used to achieve a quantitative analysis of pesticide residues, the disadvantages of these techniques, such as being time-consuming and costly and requiring specialist staff, limit their application. Therefore, there is a need to develop rapid, effective, and sensitive equipment for the quantitative analysis of pesticide residues in food. Microfluidics is rapidly emerging in a number of fields due to its outstanding strengths. This paper summarizes the application of microfluidic techniques to pyrethroid, carbamate, organochlorine, and organophosphate pesticides, as well as to commercial products. Meanwhile, the study also outlines the development of microfluidics in combination with 3D printing technology and nanomaterials for detecting pesticide residues in food.
Collapse
Affiliation(s)
- Zhuoao Jiang
- School of Mechanical Engineering, Yangzhou University, Yangzhou 225127, China; (Z.J.); (Y.Z.); (S.G.)
| | - Yu Zhuang
- School of Mechanical Engineering, Yangzhou University, Yangzhou 225127, China; (Z.J.); (Y.Z.); (S.G.)
| | - Shentian Guo
- School of Mechanical Engineering, Yangzhou University, Yangzhou 225127, China; (Z.J.); (Y.Z.); (S.G.)
| | - A. S. M. Muhtasim Fuad Sohan
- Faculty of Engineering, Department of Mechanical Engineering, The University of Adelaide, Adelaide, SA 5000, Australia;
| | - Binfeng Yin
- School of Mechanical Engineering, Yangzhou University, Yangzhou 225127, China; (Z.J.); (Y.Z.); (S.G.)
| |
Collapse
|
19
|
De Figueiredo I, Bartenlian B, Van der Rest G, Pallandre A, Halgand F. Proteomics Methodologies: The Search of Protein Biomarkers Using Microfluidic Systems Coupled to Mass Spectrometry. Proteomes 2023; 11:proteomes11020019. [PMID: 37218924 DOI: 10.3390/proteomes11020019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Revised: 04/29/2023] [Accepted: 05/07/2023] [Indexed: 05/24/2023] Open
Abstract
Protein biomarkers have been the subject of intensive studies as a target for disease diagnostics and monitoring. Indeed, biomarkers have been extensively used for personalized medicine. In biological samples, these biomarkers are most often present in low concentrations masked by a biologically complex proteome (e.g., blood) making their detection difficult. This complexity is further increased by the needs to detect proteoforms and proteome complexity such as the dynamic range of compound concentrations. The development of techniques that simultaneously pre-concentrate and identify low-abundance biomarkers in these proteomes constitutes an avant-garde approach to the early detection of pathologies. Chromatographic-based methods are widely used for protein separation, but these methods are not adapted for biomarker discovery, as they require complex sample handling due to the low biomarker concentration. Therefore, microfluidics devices have emerged as a technology to overcome these shortcomings. In terms of detection, mass spectrometry (MS) is the standard analytical tool given its high sensitivity and specificity. However, for MS, the biomarker must be introduced as pure as possible in order to avoid chemical noise and improve sensitivity. As a result, microfluidics coupled with MS has become increasingly popular in the field of biomarker discovery. This review will show the different approaches to protein enrichment using miniaturized devices and the importance of their coupling with MS.
Collapse
Affiliation(s)
- Isabel De Figueiredo
- Institut de Chimie Physique, Université Paris Saclay, Avenue Jean Perrin, F91400 Orsay, France
| | - Bernard Bartenlian
- Centre des Nanosciences et Nanotechnologies, Université Paris Saclay, 10 Boulevard Thomas Gobert, F91120 Palaiseau, France
| | - Guillaume Van der Rest
- Institut de Chimie Physique, Université Paris Saclay, Avenue Jean Perrin, F91400 Orsay, France
| | - Antoine Pallandre
- Institut de Chimie Physique, Université Paris Saclay, Avenue Jean Perrin, F91400 Orsay, France
| | - Frédéric Halgand
- Institut de Chimie Physique, Université Paris Saclay, Avenue Jean Perrin, F91400 Orsay, France
| |
Collapse
|
20
|
Point-of-care diagnostics for sepsis using clinical biomarkers and microfluidic technology. Biosens Bioelectron 2023; 227:115181. [PMID: 36867959 DOI: 10.1016/j.bios.2023.115181] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 02/13/2023] [Accepted: 02/23/2023] [Indexed: 03/05/2023]
Abstract
Sepsis is a life-threatening immune response which is caused by a wide variety of sources and is a leading cause of mortality globally. Rapid diagnosis and appropriate antibiotic treatment are critical for successful patient outcomes; however, current molecular diagnostic techniques are time-consuming, costly and require trained personnel. Additionally, there is a lack of rapid point-of-care (POC) devices available for sepsis detection despite the urgent requirements in emergency departments and low-resource areas. Recent advances have been made toward developing a POC test for early sepsis detection that will be more rapid and accurate compared to conventional techniques. Within this context, this review discusses the use of current and novel biomarkers for early sepsis diagnosis using microfluidics devices for POC testing.
Collapse
|
21
|
Li Z, Hua L, Xie L, Wang D, Jiang X. Automated Microfluidic Nucleic Acid Detection Platform-Integrated RPA-T7-Cas13a for Pathogen Diagnosis. Anal Chem 2023; 95:6940-6947. [PMID: 37083348 DOI: 10.1021/acs.analchem.3c00242] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/22/2023]
Abstract
There is a growing urgent need for point-of-care testing (POCT) devices that integrate sample pretreatment and nucleic acid detection in a rapid, economical, and non-labor-intensive way. Here, we have developed an automated, portable nucleic acid detection system employing microfluidic chips integrating rotary valve-assisted sample pretreatment and recombinase polymerase amplification (RPA)-T7-Cas13a into one-step nucleic acid detection. The RPA and clustered regularly interspaced short palindromic repeats (CRISPR)/Cas13a were integrated into a single-chamber reaction. As a validation model, we used this method to detect Group B streptococci (GBS) DNA and achieved a detection sensitivity of 8 copies/reaction, which is 6 times more sensitive than gold-standard polymerase chain reactions (PCRs). Dual specific recognition of RPA with CRISPR/Cas13a makes our method ultraspecific, with correct detection of Group B streptococci from 8 kinds of pathogenic bacteria. For the 16 positive and 24 negative clinical GBS samples, our assay achieved 100% accuracy compared to the PCR technique. The whole procedure can be automatically completed within 30 min, providing a more robust, sensitive, and accurate molecular diagnostic tool for POCT.
Collapse
Affiliation(s)
- Zheng Li
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088, Xueyuan Road, Nanshan District, Shenzhen 518055, Guangdong, China
| | - Liyan Hua
- Shaoguan Maternal and Child Health Hospital, No. 3, Dongdi South Road, Shaoguan 512026, Guangdong, China
| | - Liming Xie
- Shaoguan Maternal and Child Health Hospital, No. 3, Dongdi South Road, Shaoguan 512026, Guangdong, China
| | - Dou Wang
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088, Xueyuan Road, Nanshan District, Shenzhen 518055, Guangdong, China
| | - Xingyu Jiang
- Shenzhen Key Laboratory of Smart Healthcare Engineering, Guangdong Provincial Key Laboratory of Advanced Biomaterials, Department of Biomedical Engineering, Southern University of Science and Technology, No. 1088, Xueyuan Road, Nanshan District, Shenzhen 518055, Guangdong, China
| |
Collapse
|
22
|
Microfluidic-based blood immunoassays. J Pharm Biomed Anal 2023; 228:115313. [PMID: 36868029 DOI: 10.1016/j.jpba.2023.115313] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Revised: 02/09/2023] [Accepted: 02/22/2023] [Indexed: 02/26/2023]
Abstract
Microfluidics enables the integration of whole protocols performed in a laboratory, including sample loading, reaction, extraction, and measurement steps on a single system, which offers significant advantages thanks to small-scale operation combined with precise fluid control. These include providing efficient transportation mechanisms and immobilization, reduced sample and reagent volumes, fast analysis and response times, lower power requirements, lower cost and disposability, improved portability and sensitivity, and greater integration and automation capability. Immunoassay is a specific bioanalytical method based on the interaction of antigens and antibodies, which is utilized to detect bacteria, viruses, proteins, and small molecules in several areas such as biopharmaceutical analysis, environmental analysis, food safety, and clinical diagnostics. Because of the advantages of both techniques, the combination of immunoassays and microfluidic technology is considered one of the most potential biosensor systems for blood samples. This review presents the current progress and important developments in microfluidic-based blood immunoassays. After providing several basic information about blood analysis, immunoassays, and microfluidics, the review points out in-depth information about microfluidic platforms, detection techniques, and commercial microfluidic blood immunoassay platforms. In conclusion, some thoughts and future perspectives are provided.
Collapse
|
23
|
Smirnova A, Ohta R, Mori E, Shimizu H, Morikawa K, Kitamori T. Enzyme-linked immunosorbent assay using thin-layered microfluidics with perfect capture of the target protein. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2023; 15:675-684. [PMID: 36655604 DOI: 10.1039/d2ay01686a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
We developed a process for enzyme-linked immunosorbent assay on a glass microchip via the use of a thin-layered microfluidic channel. This channel possesses a high aspect ratio (width/depth ∼200) and has an antibody layer immobilized directly on the channel surface. A depth of several microns and an excessive width and length (mm scale) of the channel provide a large-volume capacity (102 nL) and maximum capture efficiency of the analyte for a high level of detection sensitivity (102 pg mL-1). The developed reusable immunosensor has demonstrated high-performance characteristics by requiring less than 50 μL of sample and providing analysis in less than 25 min. This new method could impact the development of point-of-care devices for biomedical applications.
Collapse
Affiliation(s)
- Adelina Smirnova
- Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-8656, Japan.
| | - Ryoichi Ohta
- Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-8656, Japan.
| | - Emi Mori
- Department of Applied Chemistry, School of Engineering, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-8656, Japan
| | - Hisashi Shimizu
- Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-8656, Japan.
| | - Kyojiro Morikawa
- Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-8656, Japan.
- Institute of Nanoengineering and Microsystems, Department of Power Mechanical Engineering, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Taiwan, Republic of China
| | - Takehiko Kitamori
- Collaborative Research Organization for Micro and Nano Multifunctional Devices, The University of Tokyo, 7-3-1, Hongo, Bunkyo, Tokyo 113-8656, Japan.
- Institute of Nanoengineering and Microsystems, Department of Power Mechanical Engineering, National Tsing Hua University, No. 101, Section 2, Kuang-Fu Road, Hsinchu 300044, Taiwan, Republic of China
- Department of Biomedical Engineering, Faculty of Engineering, Lund University, Lund 221 00, Sweden
| |
Collapse
|
24
|
Abstract
Enzyme-linked immunosorbent assay (ELISA) is widely employed for detecting target molecules in bioassays including the serological assays that measure specific antibody titers. However, ELISA tests are inherently limited to centralized laboratories staffed with trained personnel as the assay workflow requires multiple steps to be performed in a specific sequence. Here, we report a dipstick ELISA test that automates this otherwise laborious process and reports the titer of a target molecule in a digital manner without the need for an external instrument or operator. Our assay measures titer by gradually immuno-depleting the target analyte from a flowing sample effectively diluting the residual target - a process conventionally achieved through serially diluting the whole sample in numerous, time-consuming pipetting steps performed manually. Furthermore, the execution of the depletion ELISA process is automated by a built-in flow controller which sequentially delivers different reagents with preset delays. We apply the technology to develop assays measuring (1) severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antibody titers (IgM/IgG antibodies to nucleocapsid and spike protein) and (2) troponin I, a cardiac biomarker.
Collapse
Affiliation(s)
- Dohwan Lee
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, USA.
| | - Norh Asmare
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, USA.
| | - A Fatih Sarioglu
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, USA.
- Parker H. Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, USA
- Institute for Electronics and Nanotechnology, Georgia Institute of Technology, Atlanta, USA
| |
Collapse
|
25
|
Shi D, Zhang C, Li X, Yuan J. An electrochemical paper-based hydrogel immunosensor to monitor serum cytokine for predicting the severity of COVID-19 patients. Biosens Bioelectron 2023; 220:114898. [PMID: 36403494 PMCID: PMC9663147 DOI: 10.1016/j.bios.2022.114898] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Revised: 10/29/2022] [Accepted: 11/06/2022] [Indexed: 11/16/2022]
Abstract
Analysis of cytokines levels in human serum is critical as it can be a "symptom diagnostic biomarker" in COVID-19, giving real-time information about human health status. Here, we present the construction and performance of a low-price immunosensor (∼US$0.428 per test) based on microfluidic paper-based system to detect cytokine for predicting the health status of COVID-19 patients. Interleukin-6 (IL-6) was selected as the detection model for the close relationship between IL-6 and COVID-19. The assay, which we integrated into foldable paper system, leverages the magnetic immunoassay, the streptavidin-horseradish peroxidase (HRP) associated with tetramethyl benzidine/hydrogen peroxide (TMB/H2O2) to amplify the signal for electrochemical readout. To improve the sensitivity of cytokine detection, a hybrid of gold nanoparticles (AuNPs) and polypyrrole (PPy) hydrogel was modified on the working electrode to increase the conductivity and improve the electron transfer rate. With our prototypic origami paper-based immunosensor operated in differential pulse voltammetry (DPV) mode, we achieved excellent results with a dynamic range from 5 to 1000 pg/mL and a lower detection limit (LOD) of 0.654 pg/mL. Furthermore, we evaluated the capability of the clinical application of the proposed immunosensor using human serum samples from a hospital. The results indicate that our proposed immunosensor has great potential in early diagnosing high-risk COVID-19 patients.
Collapse
Affiliation(s)
- Dongmin Shi
- Department of Electronic & Computer Engineering, The Hong Kong University of Science and Technology, Hong Kong Special Administrative Region of China; Individualized Interdisciplinary Program (Microelectronics), The Hong Kong University of Science and Technology, Hong Kong Special Administrative Region of China.
| | - Chiye Zhang
- Department of Electronic & Computer Engineering, The Hong Kong University of Science and Technology, Hong Kong Special Administrative Region of China
| | - Xiaoyuan Li
- Department of Chemistry, The Hong Kong University of Science and Technology, Hong Kong Special Administrative Region of China
| | - Jie Yuan
- Department of Electronic & Computer Engineering, The Hong Kong University of Science and Technology, Hong Kong Special Administrative Region of China
| |
Collapse
|
26
|
Dou H, Wang S, Hu J, Song J, Zhang C, Wang J, Xiao L. Osteoarthritis models: From animals to tissue engineering. J Tissue Eng 2023; 14:20417314231172584. [PMID: 37223125 PMCID: PMC10201005 DOI: 10.1177/20417314231172584] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Accepted: 04/13/2023] [Indexed: 05/25/2023] Open
Abstract
Osteoarthritis (OA) is a chronic degenerative osteoarthropathy. Although it has been revealed that a variety of factors can cause or aggravate the symptoms of OA, the pathogenic mechanisms of OA remain unknown. Reliable OA models that accurately reflect human OA disease are crucial for studies on the pathogenic mechanism of OA and therapeutic drug evaluation. This review first demonstrated the importance of OA models by briefly introducing the OA pathological features and the current limitations in the pathogenesis and treatment of OA. Then, it mainly discusses the development of different OA models, including animal and engineered models, highlighting their advantages and disadvantages from the perspective of pathogenesis and pathology analysis. In particular, the state-of-the-art engineered models and their potential were emphasized, as they may represent the future direction in the development of OA models. Finally, the challenges in obtaining reliable OA models are also discussed, and possible future directions are outlined to shed some light on this area.
Collapse
Affiliation(s)
- Hongyuan Dou
- School of Biomedical Engineering, Shenzhen Campus, Sun Yat-Sen University, Shenzhen, China
| | - Shuhan Wang
- Shenzhen Institute for Drug Control, Shenzhen Testing Center of Medical Devices, Shenzhen, China
| | - Jiawei Hu
- School of Biomedical Engineering, Shenzhen Campus, Sun Yat-Sen University, Shenzhen, China
| | - Jian Song
- School of Biomedical Engineering, Shenzhen Campus, Sun Yat-Sen University, Shenzhen, China
| | - Chao Zhang
- School of Biomedical Engineering, Shenzhen Campus, Sun Yat-Sen University, Shenzhen, China
| | - Jiali Wang
- School of Biomedical Engineering, Shenzhen Campus, Sun Yat-Sen University, Shenzhen, China
| | - Lin Xiao
- School of Biomedical Engineering, Shenzhen Campus, Sun Yat-Sen University, Shenzhen, China
| |
Collapse
|
27
|
Surti PV, Kim MW, Phan LMT, Kailasa SK, Mungray AK, Park JP, Park TJ. Progress on dot-blot assay as a promising analytical tool: Detection from molecules to cells. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116736] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
28
|
Microfluidics in smart packaging of foods. Food Res Int 2022; 161:111873. [DOI: 10.1016/j.foodres.2022.111873] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2022] [Revised: 07/14/2022] [Accepted: 08/23/2022] [Indexed: 11/16/2022]
|
29
|
Zhao F, Wu W, Zhao M, Ding S, Lin Y, Hu Q, Yu L. Enzyme-like nanomaterials-integrated microfluidic technology for bioanalysis. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116833] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
30
|
Zhai T, Wei Y, Wang L, Li J, Fan C. Advancing pathogen detection for airborne diseases. FUNDAMENTAL RESEARCH 2022. [PMCID: PMC9618456 DOI: 10.1016/j.fmre.2022.10.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
Airborne diseases including SARS, bird flu, and the ongoing Coronavirus Disease 2019 (COVID-19) have stimulated the demand for developing novel bioassay methods competent for early-stage diagnosis and large-scale screening. Here, we briefly summarize the state-of-the-art methods for the detection of infectious pathogens and discuss key challenges. We highlight the trend for next-generation technologies benefiting from multidisciplinary advances in microfabrication, nanotechnology and synthetic biology, which allow sensitive, rapid yet inexpensive pathogen assays with portable intelligent device.
Collapse
Affiliation(s)
- Tingting Zhai
- School of Chemistry and Chemical Engineering, Frontiers Science Center for Transformative Molecules and National Center for Translational Medicine, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Yuhan Wei
- School of Chemistry and Chemical Engineering, Frontiers Science Center for Transformative Molecules and National Center for Translational Medicine, Shanghai Jiao Tong University, Shanghai 200240, China
| | - Lihua Wang
- The Interdisciplinary Research Center, Shanghai Synchrotron Radiation Facility, Zhangjiang Laboratory, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, China
| | - Jiang Li
- School of Chemistry and Chemical Engineering, Frontiers Science Center for Transformative Molecules and National Center for Translational Medicine, Shanghai Jiao Tong University, Shanghai 200240, China,The Interdisciplinary Research Center, Shanghai Synchrotron Radiation Facility, Zhangjiang Laboratory, Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201210, China,Corresponding authors: Prof. Jiang Li, Shanghai Jiao Tong University, The Interdisciplinary Research Center, School of Chemistry and Chemical Engineering, Frontiers Science Center for Transformative Molecules and National Center for Translational Medicine, Shanghai 200240, China
| | - Chunhai Fan
- School of Chemistry and Chemical Engineering, Frontiers Science Center for Transformative Molecules and National Center for Translational Medicine, Shanghai Jiao Tong University, Shanghai 200240, China,Corresponding authors: Prof. Jiang Li, Shanghai Jiao Tong University, The Interdisciplinary Research Center, School of Chemistry and Chemical Engineering, Frontiers Science Center for Transformative Molecules and National Center for Translational Medicine, Shanghai 200240, China
| |
Collapse
|
31
|
Negm A, Howlader MMR, Belyakov I, Bakr M, Ali S, Irannejad M, Yavuz M. Materials Perspectives of Integrated Plasmonic Biosensors. MATERIALS (BASEL, SWITZERLAND) 2022; 15:7289. [PMID: 36295354 PMCID: PMC9611134 DOI: 10.3390/ma15207289] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/26/2022] [Revised: 10/02/2022] [Accepted: 10/13/2022] [Indexed: 06/16/2023]
Abstract
With the growing need for portable, compact, low-cost, and efficient biosensors, plasmonic materials hold the promise to meet this need owing to their label-free sensitivity and deep light-matter interaction that can go beyond the diffraction limit of light. In this review, we shed light on the main physical aspects of plasmonic interactions, highlight mainstream and future plasmonic materials including their merits and shortcomings, describe the backbone substrates for building plasmonic biosensors, and conclude with a brief discussion of the factors affecting plasmonic biosensing mechanisms. To do so, we first observe that 2D materials such as graphene and transition metal dichalcogenides play a major role in enhancing the sensitivity of nanoparticle-based plasmonic biosensors. Then, we identify that titanium nitride is a promising candidate for integrated applications with performance comparable to that of gold. Our study highlights the emerging role of polymer substrates in the design of future wearable and point-of-care devices. Finally, we summarize some technical and economic challenges that should be addressed for the mass adoption of plasmonic biosensors. We believe this review will be a guide in advancing the implementation of plasmonics-based integrated biosensors.
Collapse
Affiliation(s)
- Ayman Negm
- Department of Electrical and Computer Engineering, McMaster University, Hamilton, ON L8S 4K1, Canada
- Department of Electronics and Communications Engineering, Cairo University, Giza 12613, Egypt
| | - Matiar M. R. Howlader
- Department of Electrical and Computer Engineering, McMaster University, Hamilton, ON L8S 4K1, Canada
| | - Ilya Belyakov
- Waterloo Institute for Nanotechnology, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| | - Mohamed Bakr
- Department of Electrical and Computer Engineering, McMaster University, Hamilton, ON L8S 4K1, Canada
| | - Shirook Ali
- Department of Electrical and Computer Engineering, McMaster University, Hamilton, ON L8S 4K1, Canada
- School of Mechanical and Electrical Engineering Technology, Sheridan College, Brampton, ON L6Y 5H9, Canada
| | | | - Mustafa Yavuz
- Waterloo Institute for Nanotechnology, University of Waterloo, Waterloo, ON N2L 3G1, Canada
| |
Collapse
|
32
|
Ibrahim NFA, Sabani N, Johari S, Manaf AA, Wahab AA, Zakaria Z, Noor AM. A Comprehensive Review of the Recent Developments in Wearable Sweat-Sensing Devices. SENSORS (BASEL, SWITZERLAND) 2022; 22:7670. [PMID: 36236769 PMCID: PMC9573257 DOI: 10.3390/s22197670] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Revised: 09/26/2022] [Accepted: 10/02/2022] [Indexed: 06/16/2023]
Abstract
Sweat analysis offers non-invasive real-time on-body measurement for wearable sensors. However, there are still gaps in current developed sweat-sensing devices (SSDs) regarding the concerns of mixing fresh and old sweat and real-time measurement, which are the requirements to ensure accurate the measurement of wearable devices. This review paper discusses these limitations by aiding model designs, features, performance, and the device operation for exploring the SSDs used in different sweat collection tools, focusing on continuous and non-continuous flow sweat analysis. In addition, the paper also comprehensively presents various sweat biomarkers that have been explored by earlier works in order to broaden the use of non-invasive sweat samples in healthcare and related applications. This work also discusses the target analyte's response mechanism for different sweat compositions, categories of sweat collection devices, and recent advances in SSDs regarding optimal design, functionality, and performance.
Collapse
Affiliation(s)
- Nur Fatin Adini Ibrahim
- Faculty of Electronic Engineering & Technology, Universiti Malaysia Perlis, Arau 02600, Malaysia
| | - Norhayati Sabani
- Faculty of Electronic Engineering & Technology, Universiti Malaysia Perlis, Arau 02600, Malaysia
- Center of Excellance Micro System Technology, Universiti Malaysia Perlis, Arau 02600, Malaysia
| | - Shazlina Johari
- Faculty of Electronic Engineering & Technology, Universiti Malaysia Perlis, Arau 02600, Malaysia
- Center of Excellance Micro System Technology, Universiti Malaysia Perlis, Arau 02600, Malaysia
| | - Asrulnizam Abd Manaf
- Collaborative Microelectronic Design Excellence Centre, Universiti Sains Malaysia, Gelugor 11800, Malaysia
| | - Asnida Abdul Wahab
- Department of Biomedical Engineering and Health Sciences, Universiti Teknologi Malaysia, Johor Bahru 81310, Malaysia
| | - Zulkarnay Zakaria
- Faculty of Electronic Engineering & Technology, Universiti Malaysia Perlis, Arau 02600, Malaysia
- Sports Engineering Research Center, Universiti Malaysia Perlis, Arau 02600, Malaysia
| | - Anas Mohd Noor
- Faculty of Electronic Engineering & Technology, Universiti Malaysia Perlis, Arau 02600, Malaysia
- Center of Excellance Micro System Technology, Universiti Malaysia Perlis, Arau 02600, Malaysia
| |
Collapse
|
33
|
Layne TR, Nouwairi RL, Fleming R, Blair H, Landers JP. Rapid Microchip Electrophoretic Separation of Novel Transcriptomic Body Fluid Markers for Forensic Fluid Profiling. MICROMACHINES 2022; 13:1657. [PMID: 36296010 PMCID: PMC9609788 DOI: 10.3390/mi13101657] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/23/2022] [Revised: 09/14/2022] [Accepted: 09/16/2022] [Indexed: 06/16/2023]
Abstract
Initial screening of criminal evidence often involves serological testing of stains of unknown composition and/or origin discovered at a crime scene to determine the tissue of origin. This testing is presumptive but critical for contextualizing the scene. Here, we describe a microfluidic approach for body fluid profiling via fluorescent electrophoretic separation of a published mRNA panel that provides unparalleled specificity and sensitivity. This centrifugal microfluidic approach expedites and automates the electrophoresis process by allowing for simple, rotationally driven flow and polymer loading through a 5 cm separation channel; with each disc containing three identical domains, multi-sample analysis is possible with a single disc and multi-sample detection per disc. The centrifugal platform enables a series of sequential unit operations (metering, mixing, aliquoting, heating, storage) to execute automated electrophoretic separation. Results show on-disc fluorescent detection and sizing of amplicons to perform comparably with a commercial 'gold standard' benchtop instrument and permitted sensitive, empirical discrimination between five distinct body fluids in less than 10 min. Notably, our microfluidic platform represents a faster, simpler method for separation of a transcriptomic panel to be used for forensically relevant body fluid identification.
Collapse
Affiliation(s)
- Tiffany R. Layne
- Department of Chemistry, University of Virginia, Charlottesville, VA 22939, USA
| | - Renna L. Nouwairi
- Department of Chemistry, University of Virginia, Charlottesville, VA 22939, USA
| | - Rachel Fleming
- Institute of Environmental Science and Research Limited, Auckland 1025, New Zealand
| | - Haley Blair
- Department of Chemistry, University of Virginia, Charlottesville, VA 22939, USA
| | - James P. Landers
- Department of Chemistry, University of Virginia, Charlottesville, VA 22939, USA
| |
Collapse
|
34
|
Kawakita S, Mandal K, Mou L, Mecwan MM, Zhu Y, Li S, Sharma S, Hernandez AL, Nguyen HT, Maity S, de Barros NR, Nakayama A, Bandaru P, Ahadian S, Kim HJ, Herculano RD, Holler E, Jucaud V, Dokmeci MR, Khademhosseini A. Organ-On-A-Chip Models of the Blood-Brain Barrier: Recent Advances and Future Prospects. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2022; 18:e2201401. [PMID: 35978444 PMCID: PMC9529899 DOI: 10.1002/smll.202201401] [Citation(s) in RCA: 30] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Revised: 06/22/2022] [Indexed: 05/09/2023]
Abstract
The human brain and central nervous system (CNS) present unique challenges in drug development for neurological diseases. One major obstacle is the blood-brain barrier (BBB), which hampers the effective delivery of therapeutic molecules into the brain while protecting it from blood-born neurotoxic substances and maintaining CNS homeostasis. For BBB research, traditional in vitro models rely upon Petri dishes or Transwell systems. However, these static models lack essential microenvironmental factors such as shear stress and proper cell-cell interactions. To this end, organ-on-a-chip (OoC) technology has emerged as a new in vitro modeling approach to better recapitulate the highly dynamic in vivo human brain microenvironment so-called the neural vascular unit (NVU). Such BBB-on-a-chip models have made substantial progress over the last decade, and concurrently there has been increasing interest in modeling various neurological diseases such as Alzheimer's disease and Parkinson's disease using OoC technology. In addition, with recent advances in other scientific technologies, several new opportunities to improve the BBB-on-a-chip platform via multidisciplinary approaches are available. In this review, an overview of the NVU and OoC technology is provided, recent progress and applications of BBB-on-a-chip for personalized medicine and drug discovery are discussed, and current challenges and future directions are delineated.
Collapse
Affiliation(s)
- Satoru Kawakita
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Kalpana Mandal
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Lei Mou
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
- Department of Clinical Laboratory, Third Affiliated Hospital of Guangzhou Medical University, Guangzhou Medical University, No. 63 Duobao Road, Liwan District, Guangzhou, Guangdong, 510150, P. R. China
| | | | - Yangzhi Zhu
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Shaopei Li
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Saurabh Sharma
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | | | - Huu Tuan Nguyen
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Surjendu Maity
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | | | - Aya Nakayama
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Praveen Bandaru
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Samad Ahadian
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Han-Jun Kim
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Rondinelli Donizetti Herculano
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
- Department of Bioprocess and Biotechnology Engineering, School of Pharmaceutical Sciences, São Paulo State University (Unesp), Araraquara, SP, 14801-902, Brazil
| | - Eggehard Holler
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | - Vadim Jucaud
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| | | | - Ali Khademhosseini
- Terasaki Institute for Biomedical Innovation, Los Angeles, CA, 90064, USA
| |
Collapse
|
35
|
Ahirwar R, Bhattacharya A, Kumar S. Unveiling the underpinnings of various non-conventional ELISA variants: a review article. Expert Rev Mol Diagn 2022; 22:761-774. [PMID: 36004453 DOI: 10.1080/14737159.2022.2117615] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
INTRODUCTION Enzyme-linked immunosorbent assay (ELISA) is a key bio-analytical technique used for the detection of a large array of antigenic substances of scientific, clinical, food safety, and environmental importance. The assay primarily involves capturing and detecting target analytes using specific antigen-antibody interactions. The wide usage of ELISA shoulders on its high specificity and reproducibility. Notwithstanding, the conventional microwell plate-based format of ELISA has some major drawbacks, such as long assay time (4 - 18 h), large sample volumes requirement (100 - 200 μL), lack of multiplicity, and burdensome procedures that limit its utility in rapid and affordable diagnostics. AREAS COVERED Here, we reviewed microfluidic-ELISA, paper-ELISA, aptamer-ELISA, and those based on novel incubation such as heat-ELISA, pressure-ELISA, microwave-ELISA, and sound-ELISA. Further, the current trends and future prospects of these ELISA protocols in clinical diagnostics are discussed. EXPERT OPINION The reviewed non-conventional ELISA formats are relatively rapid, require low reagent volumes, are multiplexable, and could be performed in a low-cost setup. In our opinion, these non-conventional variants of ELISA are on a par with the conventional format for clinical diagnostics and fundamental biological research and hold added clinical translational potential for quick, inexpensive, and convenient measurements.
Collapse
Affiliation(s)
- Rajesh Ahirwar
- Department of Environmental Biochemistry, ICMR-National Institute for Research in Environmental Health, Bhopal-462030, India
| | - Akanksha Bhattacharya
- Department of Environmental Biochemistry, ICMR-National Institute for Research in Environmental Health, Bhopal-462030, India
| | - Saroj Kumar
- School of Biosciences, Apeejay Stya University, Gurgaon- 122103, India
| |
Collapse
|
36
|
A Review on Potential Electrochemical Point-of-Care Tests Targeting Pandemic Infectious Disease Detection: COVID-19 as a Reference. CHEMOSENSORS 2022. [DOI: 10.3390/chemosensors10070269] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Fast and accurate point-of-care testing (POCT) of infectious diseases is crucial for diminishing the pandemic miseries. To fight the pandemic coronavirus disease 2019 (COVID-19), numerous interesting electrochemical point-of-care (POC) tests have been evolved to rapidly identify the causal organism SARS-CoV-2 virus, its nucleic acid and antigens, and antibodies of the patients. Many of those electrochemical biosensors are impressive in terms of miniaturization, mass production, ease of use, and speed of test, and they could be recommended for future applications in pandemic-like circumstances. On the other hand, self-diagnosis, sensitivity, specificity, surface chemistry, electrochemical components, device configuration, portability, small analyzers, and other features of the tests can yet be improved. Therefore, this report reviews the developmental trend of electrochemical POC tests (i.e., test platforms and features) reported for the rapid diagnosis of COVID-19 and correlates any significant advancements with relevant references. POCTs incorporating microfluidic/plastic chips, paper devices, nanomaterial-aided platforms, smartphone integration, self-diagnosis, and epidemiological reporting attributes are also surfed to help with future pandemic preparedness. This review especially screens the low-cost and easily affordable setups so that management of pandemic disease becomes faster and easier. Overall, the review is a wide-ranging package for finding appropriate strategies of electrochemical POCT targeting pandemic infectious disease detection.
Collapse
|
37
|
Ebrahimi G, Samadi Pakchin P, Shamloo A, Mota A, de la Guardia M, Omidian H, Omidi Y. Label-free electrochemical microfluidic biosensors: futuristic point-of-care analytical devices for monitoring diseases. Mikrochim Acta 2022; 189:252. [PMID: 35687204 DOI: 10.1007/s00604-022-05316-3] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2022] [Accepted: 04/20/2022] [Indexed: 10/18/2022]
Abstract
The integration of microfluidics with electrochemical analysis has resulted in the development of single miniaturized detection systems, which allows the precise control of sample volume with multianalyte detection capability in a cost- and time-effective manner. Microfluidic electrochemical sensing devices (MESDs) can potentially serve as precise sensing and monitoring systems for the detection of molecular markers in various detrimental diseases. MESDs offer several advantages, including (i) automated sample preparation and detection, (ii) low sample and reagent requirement, (iii) detection of multianalyte in a single run, (iv) multiplex analysis in a single integrated device, and (v) portability with simplicity in application and disposability. Label-free MESDs can serve an affordable real-time detection with a simple analysis in a short processing time, providing point-of-care diagnosis/detection possibilities in precision medicine, and environmental analysis. In the current review, we elaborate on label-free microfluidic biosensors, provide comprehensive insights into electrochemical detection techniques, and discuss the principles of label-free microfluidic-based sensing approaches.
Collapse
Affiliation(s)
- Ghasem Ebrahimi
- Research Center for Pharmaceutical Nanotechnology, Biomedicine Institute, Tabriz University of Medical Sciences, Tabriz, Iran.,Department of Biochemistry and Clinical Laboratories, Faculty of Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Parvin Samadi Pakchin
- Research Center for Pharmaceutical Nanotechnology, Biomedicine Institute, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Amir Shamloo
- School of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
| | - Ali Mota
- Department of Biochemistry and Clinical Laboratories, Faculty of Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| | | | - Hossein Omidian
- Department of Pharmaceutical Sciences, College of Pharmacy, Nova Southeastern University, Fort Lauderdale, FL, 33328, USA
| | - Yadollah Omidi
- Department of Pharmaceutical Sciences, College of Pharmacy, Nova Southeastern University, Fort Lauderdale, FL, 33328, USA.
| |
Collapse
|
38
|
Alexandre L, Bendali A, Pereiro I, Azimani M, Dumas S, Malaquin L, Mai TD, Descroix S. Modular microfluidic system for on-chip extraction, preconcentration and detection of the cytokine biomarker IL-6 in biofluid. Sci Rep 2022; 12:9468. [PMID: 35676309 PMCID: PMC9176165 DOI: 10.1038/s41598-022-13304-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2022] [Accepted: 05/04/2022] [Indexed: 12/17/2022] Open
Abstract
The cytokine interleukin 6 (IL-6) is involved in the pathogenesis of different inflammatory diseases, including cancer, and its monitoring could help diagnosis, prognosis of relapse-free survival and recurrence. Here, we report an innovative microfluidic approach that uses the fluidization of magnetic beads to specifically extract, preconcentrate and fluorescently detect IL-6 directly on-chip. We assess how the physical properties of the beads can be tuned to improve assay performance by enhancing mass transport, reduce non-specific binding and multiply the detection signal threefold by transitioning between packed and fluidization states. With the integration of a full ELISA protocol in a single microfluidic chamber, we show a twofold reduction in LOD compared to conventional methods along with a large dynamic range (10 pg/mL to 2 ng/mL). We additionally demonstrate its application to IL-6 detection in undiluted serum samples.
Collapse
|
39
|
Abstract
Microfluidics has enabled a new era of cellular and molecular assays due to the small length scales, parallelization, and the modularity of various analysis and actuation functions. Droplet microfluidics, in particular, has been instrumental in providing new tools for biology with its ability to quickly and reproducibly generate drops that act as individual reactors. A notable beneficiary of this technology has been single-cell RNA sequencing, which has revealed new heterogeneities and interactions for the fundamental unit of life. However, viruses far surpass the diversity of cellular life, affect the dynamics of all ecosystems, and are a chronic source of global health crises. Despite their impact on the world, high-throughput and high-resolution viral profiling has been difficult, with conventional methods being limited to population-level averaging, large sample volumes, and few cultivable hosts. Consequently, most viruses have not been identified and studied. Droplet microfluidics holds the potential to address many of these limitations and offers new levels of sensitivity and throughput for virology. This Feature highlights recent efforts that have applied droplet microfluidics to the detection and study of viruses, including for diagnostics, virus-host interactions, and cell-independent virus assays. In combination with traditional virology methods, droplet microfluidics should prove a potent tool toward achieving a better understanding of the most abundant biological species on Earth.
Collapse
Affiliation(s)
- Wenyang Jing
- Center for Biophysics and Quantitative Biology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Hee-Sun Han
- Center for Biophysics and Quantitative Biology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States.,Department of Chemistry, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States.,Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, 1206 West Gregory Drive, Urbana, Illinois 61801, United States
| |
Collapse
|
40
|
Bead Number Effect in a Magnetic-Beads-Based Digital Microfluidic Immunoassay. BIOSENSORS 2022; 12:bios12050340. [PMID: 35624641 PMCID: PMC9138409 DOI: 10.3390/bios12050340] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/21/2022] [Revised: 05/11/2022] [Accepted: 05/13/2022] [Indexed: 11/17/2022]
Abstract
In a biomedical diagnosis with a limited sample volume and low concentration, droplet-based microfluidics, also called digital microfluidics, becomes a very attractive approach. Previously, our group developed a magnetic-beads-based digital microfluidic immunoassay with a bead number of around 100, requiring less than 1 μL of sample volume to achieve a pg/mL level limit of detection (LOD). However, the bead number in each measurement was not the same, causing an unstable coefficient of variation (CV) in the calibration curve. Here, we investigated whether a fixed number of beads in this bead-based digital microfluidic immunoassay could provide more stable results. First, the bead screening chips were developed to extract exactly 100, 49, and 25 magnetic beads with diameters of less than 6 μm. Then, four calibration curves were established. One calibration curve was constructed by using varying bead numbers (50–160) in the process. The other three calibration curves used a fixed number of beads, (100, 49, and 25). The results indicated that the CVs for a fixed number of beads were evidently smaller than the CVs for varying bead numbers, especially in the range of 1 pg/mL to 100 pg/mL, where the CVs for 100 beads were less than 10%. Furthermore, the calculated LOD, based on the composite calibration curves, could be reduced by three orders, from 3.0 pg/mL (for the unfixed bead number) to 0.0287 pg/mL (for 100 beads). However, when the bead numbers were too high (more than 500) or too low (25 or fewer), the bead manipulation for aggregation became more difficult in the magnetic-beads-based digital microfluidic immunoassay chip.
Collapse
|
41
|
Sample-in-answer-out colorimetric detection of Salmonella typhimurium using non-enzymatic cascade amplification. Anal Chim Acta 2022; 1218:339850. [DOI: 10.1016/j.aca.2022.339850] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Revised: 04/13/2022] [Accepted: 04/16/2022] [Indexed: 01/03/2023]
|
42
|
Xie Y, Dai L, Yang Y. Microfluidic technology and its application in the point-of-care testing field. BIOSENSORS & BIOELECTRONICS: X 2022; 10:100109. [PMID: 35075447 PMCID: PMC8769924 DOI: 10.1016/j.biosx.2022.100109] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2021] [Revised: 01/06/2022] [Accepted: 01/09/2022] [Indexed: 05/15/2023]
Abstract
Since the outbreak of the coronavirus disease 2019 (COVID-19), countries around the world have suffered heavy losses of life and property. The global pandemic poses a challenge to the global public health system, and public health organizations around the world are actively looking for ways to quickly and efficiently screen for viruses. Point-of-care testing (POCT), as a fast, portable, and instant detection method, is of great significance in infectious disease detection, disease screening, pre-disease prevention, postoperative treatment, and other fields. Microfluidic technology is a comprehensive technology that involves various interdisciplinary disciplines. It is also known as a lab-on-a-chip (LOC), and can concentrate biological and chemical experiments in traditional laboratories on a chip of several square centimeters with high integration. Therefore, microfluidic devices have become the primary implementation platform of POCT technology. POCT devices based on microfluidic technology combine the advantages of both POCT and microfluids, and are expected to shine in the biomedical field. This review introduces microfluidic technology and its applications in combination with other technologies.
Collapse
Affiliation(s)
- Yaping Xie
- Sansure Biotech Inc., Changsha, 410205, PR China
- School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074, PR China
| | - Lizhong Dai
- Sansure Biotech Inc., Changsha, 410205, PR China
| | - Yijia Yang
- Sansure Biotech Inc., Changsha, 410205, PR China
| |
Collapse
|
43
|
Jamiruddin MR, Meghla BA, Islam DZ, Tisha TA, Khandker SS, Khondoker MU, Haq MA, Adnan N, Haque M. Microfluidics Technology in SARS-CoV-2 Diagnosis and Beyond: A Systematic Review. Life (Basel) 2022; 12:649. [PMID: 35629317 PMCID: PMC9146058 DOI: 10.3390/life12050649] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 04/21/2022] [Accepted: 04/25/2022] [Indexed: 12/22/2022] Open
Abstract
With the progression of the COVID-19 pandemic, new technologies are being implemented for more rapid, scalable, and sensitive diagnostics. The implementation of microfluidic techniques and their amalgamation with different detection techniques has led to innovative diagnostics kits to detect SARS-CoV-2 antibodies, antigens, and nucleic acids. In this review, we explore the different microfluidic-based diagnostics kits and how their amalgamation with the various detection techniques has spearheaded their availability throughout the world. Three other online databases, PubMed, ScienceDirect, and Google Scholar, were referred for articles. One thousand one hundred sixty-four articles were determined with the search algorithm of microfluidics followed by diagnostics and SARS-CoV-2. We found that most of the materials used to produce microfluidics devices were the polymer materials such as PDMS, PMMA, and others. Centrifugal force is the most commonly used fluid manipulation technique, followed by electrochemical pumping, capillary action, and isotachophoresis. The implementation of the detection technique varied. In the case of antibody detection, spectrometer-based detection was most common, followed by fluorescence-based as well as colorimetry-based. In contrast, antigen detection implemented electrochemical-based detection followed by fluorescence-based detection, and spectrometer-based detection were most common. Finally, nucleic acid detection exclusively implements fluorescence-based detection with a few colorimetry-based detections. It has been further observed that the sensitivity and specificity of most devices varied with implementing the detection-based technique alongside the fluid manipulation technique. Most microfluidics devices are simple and incorporate the detection-based system within the device. This simplifies the deployment of such devices in a wide range of environments. They can play a significant role in increasing the rate of infection detection and facilitating better health services.
Collapse
Affiliation(s)
| | - Bushra Ayat Meghla
- Department of Microbiology, Jahangirnagar University, Savar, Dhaka 1342, Bangladesh; (B.A.M.); (D.Z.I.); (T.A.T.)
| | - Dewan Zubaer Islam
- Department of Microbiology, Jahangirnagar University, Savar, Dhaka 1342, Bangladesh; (B.A.M.); (D.Z.I.); (T.A.T.)
| | - Taslima Akter Tisha
- Department of Microbiology, Jahangirnagar University, Savar, Dhaka 1342, Bangladesh; (B.A.M.); (D.Z.I.); (T.A.T.)
| | - Shahad Saif Khandker
- Gonoshasthaya-RNA Molecular Diagnostic & Research Center, Dhanmondi, Dhaka 1205, Bangladesh; (S.S.K.); (M.A.H.)
| | - Mohib Ullah Khondoker
- Department of Community Medicine, Gonoshasthaya Samaj Vittik Medical College, Savar, Dhaka 1344, Bangladesh;
| | - Md. Ahsanul Haq
- Gonoshasthaya-RNA Molecular Diagnostic & Research Center, Dhanmondi, Dhaka 1205, Bangladesh; (S.S.K.); (M.A.H.)
| | - Nihad Adnan
- Department of Microbiology, Jahangirnagar University, Savar, Dhaka 1342, Bangladesh; (B.A.M.); (D.Z.I.); (T.A.T.)
| | - Mainul Haque
- The Unit of Pharmacology, Faculty of Medicine and Defence Health, Universiti Pertahanan Nasional Malaysia (National Defence University of Malaysia), Kem Perdana Sugai Besi, Kuala Lumpur 57000, Malaysia
| |
Collapse
|
44
|
Chozinski T, Ferguson BS, Fisher W, Ge S, Gong Q, Kang H, McDermott J, Scott A, Shi W, Trausch JJ, Verch T, Vukovich M, Wang J, Wu JE, Yang Q. Development of an Aptamer-Based Electrochemical Microfluidic Device for Viral Vaccine Quantitation. Anal Chem 2022; 94:6146-6155. [PMID: 35410467 DOI: 10.1021/acs.analchem.1c05093] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Global deployment of vaccines poses significant challenges in the distribution and use of the accompanying immunoassays, one of the standard methods for quality control of vaccines, particularly when establishing assays in countries worldwide to support testing/release upon importation. This work describes our effort toward developing an integrated, portable device to carry out affinity assays for viral particles quantification in viral vaccines by incorporating (i) aptamers, (ii) microfluidic devices, and (iii) electrochemical detection. We generated and characterized more than eight aptamers against multiple membrane proteins of cytomegalovirus (CMV), which we used as a model system and designed and fabricated electrochemical microfluidic devices to measure CMV concentrations in a candidate vaccine under development. The aptamer-based assays provided a half maximal effective concentration, EC50, of 12 U/mL, comparable to that of an ELISA using a pair of antibodies (EC50 60 U/mL). The device measured relative CMV concentrations accurately (within ±10% bias) and precisely (11%, percent relative standard deviation). This work represents the critical first steps toward developing simple, affordable, and robust affinity assays for global deployment without the need for sensitive equipment and extensive analyst training.
Collapse
Affiliation(s)
- Tyler Chozinski
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| | - B Scott Ferguson
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| | - William Fisher
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| | - Shencheng Ge
- Merck & Co., Inc., 770 Sumneytown Pike, West Point, Pennsylvania 19486, United States
| | - Qiang Gong
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| | - Hui Kang
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| | - John McDermott
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| | - Alexander Scott
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| | - Wentao Shi
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| | - Jeremiah J Trausch
- Merck & Co., Inc., 770 Sumneytown Pike, West Point, Pennsylvania 19486, United States
| | - Thorsten Verch
- Merck & Co., Inc., 770 Sumneytown Pike, West Point, Pennsylvania 19486, United States
| | - Matthew Vukovich
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| | - Jinpeng Wang
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| | - J Emma Wu
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| | - Qin Yang
- Aptitude Medical Systems, 125 Cremona Drive, Suite 100, Goleta, California 93117, United States
| |
Collapse
|
45
|
Xi J, Cui G, Dong M, Sun C, Wang Y, Xu N, Zhang J, Wang L. Bioinspired fabrication of bifunctional antibody-enzyme co-assembled nanocomposites for chemiluminescence immunoassays of E. coli O157:H7. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:1414-1419. [PMID: 35311849 DOI: 10.1039/d2ay00269h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Immunoassays based on enzyme-labeled antibodies have been widely used in the food safety field. However, the production process of enzyme-labeled antibodies is complicated and the low storage stability limits their application. Herein, antibody-horseradish peroxidase (HRP) co-assembled nanocomposites (AHC NCs) with outstanding advantages such as enhanced stability, lower cost, and substrate affinity were successfully prepared via a one-pot green method. Then the AHC NCs were employed as an alternative to traditional enzyme-labeled antibodies to develop a chemiluminescence enzyme immunoassay (CLEIA) toward Escherichia coli (E. coli) O157:H7. Under optimal conditions, E. coli O157:H7 can be detected in a linear range from 1 × 103 CFU mL-1 to 5 × 106 CFU mL-1, while the limit of detection (LOD) is as low as 2.2 × 102 CFU mL-1 (3σ). A series of repeatability studies showed reproducible results with a coefficient of variation of less than 7%. In addition, the proposed CLEIA was successfully applied to the analysis of spiked samples (tap water) and gave quantitative recoveries from 93.72% to 100.72%. This work demonstrates that the developed CLEIA can be applied as a universal platform for specific detection of diversified analytes.
Collapse
Affiliation(s)
- Jinnan Xi
- College of Animal Science and Technology, Jilin Agricultural University, Changchun, 130118, P. R. China.
| | - Guihua Cui
- Jilin Medical University, Jilin, 132013, P. R. China.
| | - Mingxin Dong
- Changchun Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Changchun, 130122, P. R. China.
| | - Chengbiao Sun
- Changchun Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Changchun, 130122, P. R. China.
| | - Yan Wang
- Changchun Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Changchun, 130122, P. R. China.
| | - Na Xu
- Jilin Medical University, Jilin, 132013, P. R. China.
| | - Jianxu Zhang
- Changchun Veterinary Research Institute, Chinese Academy of Agricultural Sciences, Changchun, 130122, P. R. China.
| | - Longtao Wang
- College of Animal Science and Technology, Jilin Agricultural University, Changchun, 130118, P. R. China.
| |
Collapse
|
46
|
Wang Z, Jiang H, Wu G, Li Y, Zhang T, Zhang Y, Wang X. Shape-Programmable Three-Dimensional Microfluidic Structures. ACS APPLIED MATERIALS & INTERFACES 2022; 14:15599-15607. [PMID: 35319180 PMCID: PMC9552124 DOI: 10.1021/acsami.1c24799] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Microfluidic devices are gaining extensive interest due to their potential applications in wide-ranging areas, including lab-on-a-chip devices, fluid delivery, and artificial vascular networks. Most current microfluidic devices are in a planar design with fixed configurations once formed, which limits their applications such as in engineered vascular networks in biology and programmable drug delivery systems. Here, shape-programmable three-dimensional (3D) microfluidic structures, which are assembled from a bilayer of channel-embedded polydimethylsiloxane (PDMS) and shape-memory polymers (SMPs) via compressive buckling, are reported. 3D microfluidics in diverse geometries including those in open-mesh configurations are presented. In addition, they can be programmed into temporary shapes and recover their original shape under thermal stimuli due to the shape memory effect of the SMP component, with fluid flow in the microfluidic channels well maintained in both deformed and recovered shapes. Furthermore, the shape-fixing effect of SMPs enables freestanding open-mesh 3D microfluidic structures without the need for a substrate to maintain the 3D shape as used in previous studies. By adding magnetic particles into the PDMS layer, magnetically responsive 3D microfluidic structures are enabled to achieve fast, remote programming of the structures via a portable magnet. A 3D design phase diagram is constructed to show the effects of the magnetic PDMS/SMP thickness ratio and the volume fraction of magnetic particles on the shape programmability of the 3D microfluidic structures. The developed shape-programmable, open-mesh 3D microfluidic structures offer many opportunities for applications including tissue engineering, drug delivery, and many others.
Collapse
Affiliation(s)
- Zizheng Wang
- Department of Materials Science and Engineering, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Hao Jiang
- Department of Mechanical and Aerospace Engineering, Syracuse University, Syracuse, New York 13244, United States
| | - Guangfu Wu
- Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Yi Li
- Department of Materials Science and Engineering, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Teng Zhang
- Department of Mechanical and Aerospace Engineering, Syracuse University, Syracuse, New York 13244, United States
- BioInspired Syracuse, Syracuse University, Syracuse, New York 13244, United States
| | - Yi Zhang
- Department of Biomedical Engineering, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Xueju Wang
- Department of Materials Science and Engineering, University of Connecticut, Storrs, Connecticut 06269, United States
- Polymer Program, University of Connecticut, Storrs, Connecticut 06269, United States
| |
Collapse
|
47
|
Flores-Contreras EA, González-González RB, Rodríguez-Sánchez IP, Yee-de León JF, Iqbal HMN, González-González E. Microfluidics-Based Biosensing Platforms: Emerging Frontiers in Point-of-Care Testing SARS-CoV-2 and Seroprevalence. BIOSENSORS 2022; 12:179. [PMID: 35323449 PMCID: PMC8946853 DOI: 10.3390/bios12030179] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/12/2022] [Revised: 03/13/2022] [Accepted: 03/15/2022] [Indexed: 02/05/2023]
Abstract
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) caused the ongoing COVID-19 (coronavirus disease-2019) outbreak and has unprecedentedly impacted the public health and economic sector. The pandemic has forced researchers to focus on the accurate and early detection of SARS-CoV-2, developing novel diagnostic tests. Among these, microfluidic-based tests stand out for their multiple benefits, such as their portability, low cost, and minimal reagents used. This review discusses the different microfluidic platforms applied in detecting SARS-CoV-2 and seroprevalence, classified into three sections according to the molecules to be detected, i.e., (1) nucleic acid, (2) antigens, and (3) anti-SARS-CoV-2 antibodies. Moreover, commercially available alternatives based on microfluidic platforms are described. Timely and accurate results allow healthcare professionals to perform efficient treatments and make appropriate decisions for infection control; therefore, novel developments that integrate microfluidic technology may provide solutions in the form of massive diagnostics to control the spread of infectious diseases.
Collapse
Affiliation(s)
- Elda A. Flores-Contreras
- Tecnologico de Monterrey, School of Engineering and Sciences, Monterrey 64849, Nuevo León, Mexico; (E.A.F.-C.); (R.B.G.-G.)
| | | | - Iram P. Rodríguez-Sánchez
- Laboratorio de Fisiología Molecular y Estructural, Facultad de Ciencias Biológicas, Universidad Autónoma de Nuevo León, San Nicolás de los Garza 66455, Nuevo León, Mexico;
| | | | - Hafiz M. N. Iqbal
- Tecnologico de Monterrey, School of Engineering and Sciences, Monterrey 64849, Nuevo León, Mexico; (E.A.F.-C.); (R.B.G.-G.)
| | - Everardo González-González
- Laboratorio de Fisiología Molecular y Estructural, Facultad de Ciencias Biológicas, Universidad Autónoma de Nuevo León, San Nicolás de los Garza 66455, Nuevo León, Mexico;
| |
Collapse
|
48
|
Mou L, Zhang Y, Feng Y, Hong H, Xia Y, Jiang X. Multiplexed Lab-on-a-Chip Bioassays for Testing Antibodies against SARS-CoV-2 and Its Variants in Multiple Individuals. Anal Chem 2022; 94:2510-2516. [PMID: 35080377 PMCID: PMC8805706 DOI: 10.1021/acs.analchem.1c04383] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Accepted: 01/17/2022] [Indexed: 01/04/2023]
Abstract
Neutralization assays that can measure neutralizing antibodies in serum are vital for large-scale serodiagnosis and vaccine evaluation. Here, we establish multiplexed lab-on-a-chip bioassays for testing antibodies against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and its variants. Compared with enzyme-linked immunosorbent assay (ELISA), our method exhibits a low consumption of sample and reagents (10 μL), a low limit of detection (LOD: 0.08 ng/mL), a quick sample-to-answer time (about 70 min), and multiplexed ability (5 targets in each of 7 samples in one assay). We can also increase the throughput as needed. The concentrations of antibodies against RBD, D614G, N501Y, E484K, and L452R/E484Q-mutants after two doses of vaccines are 6.6 ± 3.6, 8.7 ± 4.6, 3.4 ± 2.8, 3.8 ± 2.8, and 2.8 ± 2.3 ng/mL, respectively. This suggests that neutralizing activities against N501Y, E484K, and L452R/E484Q-mutants were less effective than RBD and D614G-mutant. We performed a plaque reduction neutralization test (PRNT) for all volunteers. Compared with PRNT, our assay is fast, accurate, inexpensive, and multiplexed with multiple-sample processing ability, which is good for large-scale serodiagnosis and vaccine evaluation.
Collapse
Affiliation(s)
- Lei Mou
- Department
of Clinical Laboratory, Third Affiliated
Hospital of Guangzhou Medical University, No. 63 Duobao Road, Liwan District, Guangzhou, Guangdong 510150, P. R. China
- Department
of Biomedical Engineering, Southern University
of Science and Technology, No. 1088, Xueyuan Road, Xili, Nanshan District, Shenzhen, Guangdong 518055, P. R. China
| | - Yingying Zhang
- Department
of Clinical Laboratory, Third Affiliated
Hospital of Guangzhou Medical University, No. 63 Duobao Road, Liwan District, Guangzhou, Guangdong 510150, P. R. China
- Department
of Clinical Laboratory, Bao’an Authentic
TCM Therapy Hospital, No. 99, Laian Road, Baoan District, Shenzhen, Guangdong 518101, P. R. China
| | - Yao Feng
- Department
of Clinical Laboratory, Third Affiliated
Hospital of Guangzhou Medical University, No. 63 Duobao Road, Liwan District, Guangzhou, Guangdong 510150, P. R. China
| | - Honghai Hong
- Department
of Clinical Laboratory, Third Affiliated
Hospital of Guangzhou Medical University, No. 63 Duobao Road, Liwan District, Guangzhou, Guangdong 510150, P. R. China
| | - Yong Xia
- Department
of Clinical Laboratory, Third Affiliated
Hospital of Guangzhou Medical University, No. 63 Duobao Road, Liwan District, Guangzhou, Guangdong 510150, P. R. China
| | - Xingyu Jiang
- Department
of Clinical Laboratory, Third Affiliated
Hospital of Guangzhou Medical University, No. 63 Duobao Road, Liwan District, Guangzhou, Guangdong 510150, P. R. China
- Department
of Biomedical Engineering, Southern University
of Science and Technology, No. 1088, Xueyuan Road, Xili, Nanshan District, Shenzhen, Guangdong 518055, P. R. China
| |
Collapse
|
49
|
Li D, Huang M, Shi Z, Huang L, Jin J, Jiang C, Yu W, Guo Z, Wang J. Ultrasensitive Competitive Lateral Flow Immunoassay with Visual Semiquantitative Inspection and Flexible Quantification Capabilities. Anal Chem 2022; 94:2996-3004. [PMID: 35107983 DOI: 10.1021/acs.analchem.1c05364] [Citation(s) in RCA: 35] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Antibiotics abuse has caused various problems threatening human health and ecological environment. Monitoring antibiotics residual levels is of great significance, yet still challenging for quantitative point-of-need testing with high-sensitivity and visual capability. Here we developed a competitive lateral flow immunoassay (CLFIA) platform with flexible readout for enrofloxacin (ENR), a regularly added antibiotic. To overcome the limitation of low sensitivity of traditional colloidal gold-based CLFIA, the three-dimensionally assembled gold nanoparticles (AuNPs) within dendritic silica scaffold were fabricated as signal reporters. The assembly structure effectively retained the intrinsic absorption features of hydrophobic AuNPs and greatly enhanced the light extinction ability of a single label for signal amplification. The obtained CLFIA strips can not only achieve qualitative screening of ENR at a very low concentration by naked eye (cutoff value: 0.125 ng/mL), but also enable ultrasensitive quantification of ENR by an optical scanner (limit of detection: 0.00195 ng/mL) or a smartphone (limit of detection: 0.0078 ng/mL). Moreover, to elaborate the visual inspection degree of CLFIA against traditional yes/no interpretation, a novel multirange gradient CLFIA strip was prepared for visually semiquantitative identification of ENR with four concentration ranges. The novel CLFIA platform demonstrated sensitive, specific, and reliable determination of ENR with flexible signal readout and provides a potential and invigorating pathway to point-of-need immunoassay of antibiotics.
Collapse
Affiliation(s)
- Daquan Li
- College of Chemical Engineering, Zhejiang University of Technology. Hangzhou 310014, (PR China)
| | - Mei Huang
- College of Chemical Engineering, Zhejiang University of Technology. Hangzhou 310014, (PR China)
| | - Ziyu Shi
- College of Chemical Engineering, Zhejiang University of Technology. Hangzhou 310014, (PR China)
| | - Liang Huang
- College of Chemical Engineering, Zhejiang University of Technology. Hangzhou 310014, (PR China)
| | - Jiening Jin
- College of Chemical Engineering, Zhejiang University of Technology. Hangzhou 310014, (PR China)
| | - Chenxing Jiang
- College of Chemical Engineering, Zhejiang University of Technology. Hangzhou 310014, (PR China)
| | - Wenbo Yu
- College of Veterinary Medicine, China Agricultural University. Beijing 100193 (PR China)
| | - Zhiyong Guo
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, School of Material Science and Chemical Engineering, Ningbo University, Ningbo 315211(PR China)
| | - Jing Wang
- College of Chemical Engineering, Zhejiang University of Technology. Hangzhou 310014, (PR China)
| |
Collapse
|
50
|
Iria I, Soares RRG, Brás EJS, Chu V, Gonçalves J, Conde JP. Accurate and rapid microfluidic ELISA to monitor Infliximab titers in patients with inflammatory bowel diseases. Analyst 2022; 147:480-488. [PMID: 35023516 DOI: 10.1039/d1an01810h] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
Inflammatory bowel disease (IBD) is a term used to describe disorders that involve chronic inflammation in the gastrointestinal tract, affecting more than 6.8 million people worldwide. Biological therapy is used in the most severe cases of IBD where anti-tumour necrosis factor-alpha (TNF-α) antibodies are the first choice for a biological treatment. When administrated to patients, these antibodies interact with TNF-α, usually overexpressed in these diseases, neutralizing its biological activity. Because of the chronic nature of these diseases, a recurring administration of the therapeutic antibodies is required, thus making therapy monitorization essential for the correct management of these diseases. The aim of this work is the development of an enzyme-linked immunosorbent assay (ELISA) microfluidic biosensor to quantify the therapeutic antibodies in IBD patient plasma samples, where the commercial monoclonal antibody Infliximab (IFX) is used as a model target. By providing a faster and more accurate measurement of IFX, the proposed method leads to improved therapy scheduling and a reduced risk of endogenous anti-drug antibodies (ADAs) reducing the efficacy of the treatment. The time needed between sample insertion and result output for the microfluidic ELISA (mELISA) is 24 minutes, drastically shorter than the time required by the conventional ELISA (cELISA). The mELISA presented in this work has a LoD of 0.026 μg mL-1, while commercially available solutions provide a LoD of 0.15 μg mL-1. Results acquired by the mELISA are highly correlated with the results obtained from the cELISA (r = 0.998; R2 = 0.996; p < 0.0001), demonstrating the validity of the microfluidic approach for the quantification of IFX from patient plasma and its potential for use at the point-of-care (POC).
Collapse
Affiliation(s)
- Inês Iria
- Instituto de Engenharia de Sistemas e Computadores - Microsistemas e Nanotecnologias (INESC MN), Rua Alves Redol, 9, 1000-029 Lisbon, Portugal. .,Research Institute for Medicines (iMed ULisboa), Faculdade de Farmácia, Universidade de Lisboa, Av. Professor Gama Pinto, 1649-003, Lisbon, Portugal
| | - Ruben R G Soares
- Instituto de Engenharia de Sistemas e Computadores - Microsistemas e Nanotecnologias (INESC MN), Rua Alves Redol, 9, 1000-029 Lisbon, Portugal. .,IBB - Institute for Bioengineering and Biosciences, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais 1, 1049-001, Lisbon, Portugal
| | - Eduardo J S Brás
- Instituto de Engenharia de Sistemas e Computadores - Microsistemas e Nanotecnologias (INESC MN), Rua Alves Redol, 9, 1000-029 Lisbon, Portugal. .,IBB - Institute for Bioengineering and Biosciences, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais 1, 1049-001, Lisbon, Portugal
| | - Virginia Chu
- Instituto de Engenharia de Sistemas e Computadores - Microsistemas e Nanotecnologias (INESC MN), Rua Alves Redol, 9, 1000-029 Lisbon, Portugal.
| | - João Gonçalves
- Research Institute for Medicines (iMed ULisboa), Faculdade de Farmácia, Universidade de Lisboa, Av. Professor Gama Pinto, 1649-003, Lisbon, Portugal
| | - João P Conde
- Instituto de Engenharia de Sistemas e Computadores - Microsistemas e Nanotecnologias (INESC MN), Rua Alves Redol, 9, 1000-029 Lisbon, Portugal. .,Department of Bioengineering, Instituto Superior Técnico, Universidade de Lisboa, Av. Rovisco Pais 1, 1049-001, Lisbon, Portugal.
| |
Collapse
|