Panditharatne SP, Imali DY, Perera ECJ, Perera LHR, Hettiarachchi GHCM, Kaumal MN. Anodized CuO-based reusable non-enzymatic glucose sensor as an alternative method for the analysis of pharmaceutical glucose infusions: a cyclic voltammetric approach. ANAL SCI 2024; 40:1475-1487. [PMID: 38727930 DOI: 10.1007/s44211-024-00585-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2024] [Accepted: 04/22/2024] [Indexed: 07/26/2024]
Abstract
Analyzing pharmaceutical products is a quality control requirement in a production facility. This study presents a CuO electrode-based reusable non-enzymatic sensor as an alternative method for rapid analysis of glucose levels in glucose infusions. CuO is extensively employed as an electrode material in non-enzymatic glucose sensors. Conventionally, these electrodes are fabricated using chemical synthesis of CuO followed by immobilization to the electrode substrate. In contrast, here, Cu metal was mechanically modified to create a grooved surface, followed by electrochemical anodization and subsequent annealing process to grow a seamless CuO layer in situ with enhanced catalytic activity. The morphology of the electrodes was characterized using scanning electron microscopy (SEM) and X-ray diffractometry (XRD). The direct electrocatalytic activity of the developed CuO-modified electrode towards glucose oxidation in alkaline media was investigated by cyclic voltammetry in detail. The CuO-modified electrode commenced the oxidation process around 0.10 V vs. Ag pseudo-reference electrode, demonstrating a significant reduction in the overvoltage for glucose oxidation compared to the bare Cu electrode. The sensor is capable of detecting glucose at low oxidation potentials such as 0.2 V with a sensitivity value of 0.37 µA ppm-1, a wide linear range (80-2300 ppm), limit of quantification (LOQ) of 1 ppm, greater repeatability, 1% precision, 3% bias, a short response time (80 s), good reproducibility and excellent reusability (196 consecutive attempts). The enhanced performance and cost-effectiveness make this sensor a promising alternative method for product analysis in glucose injection solutions.
Collapse
Affiliation(s)
| | - D Yureka Imali
- Department of Chemistry, University of Colombo, Colombo 03, Sri Lanka
| | - E Chavin J Perera
- Department of Chemistry, University of Colombo, Colombo 03, Sri Lanka
| | - L Hasini R Perera
- Department of Chemistry, University of Colombo, Colombo 03, Sri Lanka.
| | | | - M N Kaumal
- Department of Chemistry, University of Colombo, Colombo 03, Sri Lanka
| |
Collapse
|
2
|
Selvi Gopal T, James JT, Gunaseelan B, Ramesh K, Raghavan V, Malathi A CJ, Amarnath K, Kumar VG, Rajasekaran SJ, Pandiaraj S, MR M, Pitchaimuthu S, Abeykoon C, Alodhayb AN, Grace AN. MXene-Embedded Porous Carbon-Based Cu 2O Nanocomposites for Non-Enzymatic Glucose Sensors. ACS OMEGA 2024; 9:8448-8456. [PMID: 38405472 PMCID: PMC10882672 DOI: 10.1021/acsomega.3c09659] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 01/25/2024] [Accepted: 01/31/2024] [Indexed: 02/27/2024]
Abstract
This work explores the use of MXene-embedded porous carbon-based Cu2O nanocomposite (Cu2O/M/AC) as a sensing material for the electrochemical sensing of glucose. The composite was prepared using the coprecipitation method and further analyzed for its morphological and structural characteristics. The highly porous scaffold of activated (porous) carbon facilitated the incorporation of MXene and copper oxide inside the pores and also acted as a medium for charge transfer. In the Cu2O/M/AC composite, MXene and Cu2O influence the sensing parameters, which were confirmed using electrochemical techniques such as cyclic voltammetry, electrochemical impedance spectroscopy, and amperometric analysis. The prepared composite shows two sets of linear ranges for glucose with a limit of detection (LOD) of 1.96 μM. The linear range was found to be 0.004 to 13.3 mM and 15.3 to 28.4 mM, with sensitivity values of 430.3 and 240.5 μA mM-1 cm-2, respectively. These materials suggest that the prepared Cu2O/M/AC nanocomposite can be utilized as a sensing material for non-enzymatic glucose sensors.
Collapse
Affiliation(s)
- Tami Selvi Gopal
- Centre
for Nanotechnology Research, Vellore Institute
of Technology, Vellore, Tamil Nadu 632014, India
| | - Jaimson T. James
- Centre
for Nanotechnology Research, Vellore Institute
of Technology, Vellore, Tamil Nadu 632014, India
| | - Bharath Gunaseelan
- Centre
for Nanotechnology Research, Vellore Institute
of Technology, Vellore, Tamil Nadu 632014, India
| | - Karthikeyan Ramesh
- Centre
for Nanotechnology Research, Vellore Institute
of Technology, Vellore, Tamil Nadu 632014, India
| | - Vimala Raghavan
- Centre
for Nanotechnology Research, Vellore Institute
of Technology, Vellore, Tamil Nadu 632014, India
| | - Christina Josephine Malathi A
- Department
of Communication Engineering, School of Electronics Engineering (SENSE), Vellore Institute of Technology, Vellore, Tamil Nadu 632014, India
| | - K. Amarnath
- Department
of Chemistry and Centre for Ocean Research, Sathyabama Institute of Science and Technology, Chennai 600119, India
| | - V. Ganesh Kumar
- Department
of Chemistry and Centre for Ocean Research, Sathyabama Institute of Science and Technology, Chennai 600119, India
| | | | - Saravanan Pandiaraj
- Department
of Self-Development Skills, King Saud University, Riyadh 11451, Saudi Arabia
| | | | - Sudhagar Pitchaimuthu
- Research
Centre for Carbon Solutions, Institute of Mechanical, Processing and
Energy Engineering, School of Engineering & Physical Sciences, Heriot-Watt University, Edinburgh EH14 4AS, U.K.
| | - Chamil Abeykoon
- Northwest
Composites Centre, Aerospace Research Institute, and Department of
Materials, Faculty of Science and Engineering, The University of Manchester, Oxford Road, Manchester M13 9PL, U.K.
| | - Abdullah N. Alodhayb
- Department
of Physics and Astronomy, College of Science, King Saud University, Riyadh 11451, Saudi Arabia
| | - Andrews Nirmala Grace
- Centre
for Nanotechnology Research, Vellore Institute
of Technology, Vellore, Tamil Nadu 632014, India
| |
Collapse
|
3
|
Ali MY, Abdulrahman HB, Ting WT, Howlader MMR. Green synthesized gold nanoparticles and CuO-based nonenzymatic sensor for saliva glucose monitoring. RSC Adv 2024; 14:577-588. [PMID: 38173614 PMCID: PMC10758929 DOI: 10.1039/d3ra05644a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Accepted: 11/30/2023] [Indexed: 01/05/2024] Open
Abstract
Glucose, essential for brain and muscle functions, requires careful monitoring in diabetes and other chronic disease management. While blood glucose monitoring provides precise information about these diseases, it remains an invasive method. Saliva glucose monitoring could offer an alternative approach, but the glucose concentration in saliva is very low. In this work, we report a simple, low-cost, highly sensitive nonenzymatic electrochemical glucose sensor. We developed this sensor using green synthesized gold nanoparticles (AuNPs) and wet chemical synthesized copper oxide (CuO) nanoparticles on a screen-printed carbon electrode (Au/CuO/SPCE). The sensor's high sensitivity results from dual amplification strategies using AuNPs and CuO nanomaterials, each demonstrating catalytic activity towards glucose. This shows promising potential for saliva glucose monitoring. The AuNPs were synthesized using an Au precursor and orange peel extract (OPE), yielding stable colloidal AuNPs with a mean diameter of about 37 nm, thus eliminating the need for additional capping agents. Under optimal conditions, amperometric tests revealed that the sensor responded linearly to glucose concentrations ranging from 2 μM to 397 μM with a sensitivity of 236.70 μA mM-1 cm-2. Furthermore, the sensor demonstrated excellent reproducibility, stability and high selectivity for glucose in the presence of different biomolecules. We validated the sensor's efficacy by measuring glucose in human saliva, showing its potential for noninvasive glucose monitoring. This research advances the development of point-of-care devices, positioning the sensor as a promising tool for noninvasive glucose monitoring and improved diabetes management.
Collapse
Affiliation(s)
- Md Younus Ali
- Department of Electrical and Computer Engineering, McMaster University 1280 Main Street West Hamilton ON L8S 4K1 Canada
| | - Heman B Abdulrahman
- Department of Electrical and Computer Engineering, McMaster University 1280 Main Street West Hamilton ON L8S 4K1 Canada
| | - Wei-Ting Ting
- Department of Electrical and Computer Engineering, McMaster University 1280 Main Street West Hamilton ON L8S 4K1 Canada
| | - Matiar M R Howlader
- Department of Electrical and Computer Engineering, McMaster University 1280 Main Street West Hamilton ON L8S 4K1 Canada
| |
Collapse
|
4
|
Hassan IU. Diabetes Management by Fourth-Generation Glucose Sensors Based on Lemon-Extract-Supported CuO Nanoporous Materials. Molecules 2023; 28:6763. [PMID: 37836606 PMCID: PMC10574443 DOI: 10.3390/molecules28196763] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Revised: 09/11/2023] [Accepted: 09/18/2023] [Indexed: 10/15/2023] Open
Abstract
Diabetes is a major worldwide health issue, impacting millions of people around the globe and putting pressure on healthcare systems. Accurate detection of glucose is critical for efficient diabetes care, because it allows for prompt action to control blood sugar levels and avoid problems. Reliable glucose-sensing devices provide individuals with real-time information, allowing them to make more educated food, medicine, and lifestyle decisions. The progress of glucose sensing holds the key to increasing the quality of life for diabetics and lowering the burden of this prevalent condition. The present investigation addresses the synthesis of a CuO@lemon-extract nanoporous material using the sol-gel process. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were used to analyze the morphological properties of the composite, which revealed a homogeneous integration of CuO nanoparticles (NPs) on the surface of the matrix. The existence of primarily oxidized copper species, especially CuO, was confirmed by X-ray diffraction spectroscopy (XRD) investigation in combination with energy-dispersive X-ray (EDX) spectroscopy. The CuO@lemon-extract-modified glassy carbon electrode (CuO@lemon-extract GCE) performed well in non-enzymatic electrochemical sensing applications such as differential pulse voltammetry (DPV) and amperometric glucose detection. The electrode achieved a notable sensitivity of 3293 µA mM-1 cm-2 after careful adjustment, with a noticeable detection limit of 0.01 µM (signal-to-noise ratio of 3). The operational range of the electrode was 0.01 µM to 0.2 µM, with potential applied of 0.53 V vs. Ag/AgCl. These findings underscore the CuO@lemon-extract GCE's promise as a robust and reliable platform for electrochemical glucose sensing, promising advances in non-enzymatic glucose sensing (NEGS) techniques.
Collapse
Affiliation(s)
- Israr U Hassan
- Department of Mathematics & Sciences, College of Arts & Applied Sciences, Dhofar University, Salalah PC 211, Oman
| |
Collapse
|
5
|
Manibalan G, Murugadoss G, Jayavel R, Rajesh Kumar M, Pugazhendhi A. Facile route of heterostructure CeO 2-CuO nanocomposite as an efficient electron transport material for perovskite solar cells. ENVIRONMENTAL RESEARCH 2023; 228:115853. [PMID: 37059326 DOI: 10.1016/j.envres.2023.115853] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Revised: 03/30/2023] [Accepted: 04/03/2023] [Indexed: 05/16/2023]
Abstract
Cerium copper metal nanostructures have received extensive attention as promising electrode materials for energy storage applications due to its attractive structure, and good conductivity. Herein, CeO2-CuO nanocomposite was prepared via chemical method. The crystal structure, dielectric, and magnetic properties of the samples were characterized using by different techniques. The morphological properties of samples were inspected by field emission scanning electron microscopy (FE‒SEM) and high-resolution transmission electron microcopy (HR‒TEM) analysis implied an agglomerated with nanorod structure. The sample surface roughness and morphology were inspected using atomic force microscopy (AFM). Electron paramagnetic resonance (EPR) spectroscopy result reveals the oxygen insufficiency in the material. The variation of oxygen vacancies concentration is consistent with the changes of the saturation magnetization for the sample. Dielectric constant and dielectric losses were studied with respect to the temperature from range from 150 to 350 °C. The electrochemical study of CeO2-CuO nanocomposite shows clear oxidation and reduction peaks with covering wide potential range. In this present paper, first time we have demonstrated that the CeO2-CuO composite as an electron transport material (ETM) with copper (I) thiocyanate (CuSCN) as hole transport material (HTM) for the perovskite solar cells device fabrication. To understand the properties of perovskite like structural, optical, and morphological extensive characterizations such as XRD, UV-visible spectroscopy, and FE-SEM, was performed. For the first time, the CeO2-CuO was used as anode material for preparation low-temperature processing perovskite solar cells, results the power conversion efficiency (PCE) of 10.58% was achieved. The improvement in the device performance for the nanocomposite compared to the pure CeO2, due to unique properties of CeO2-CuO, including high hole mobility, good energy level alignment with CH3NH3PbI3 and longer life time of photo-excited carriers for facilitating the developments of industrial-scale perovskite solar cells.
Collapse
Affiliation(s)
- Gunasekaran Manibalan
- Department of Chemistry, Indian Institute of Technology Bombay, Mumbai, 400 076, Maharashtra, India
| | - Govindhasamy Murugadoss
- Centre for Nanoscience and Nanotechnology, Sathyabama Institute of Science and Technology, Chennai, 600 119, Tamil Nadu, India.
| | - Ramasamy Jayavel
- Centre for Nanoscience and Technology, Anna University, Chennai, 600 025, Tamil Nadu, India
| | - Manavalan Rajesh Kumar
- Institute of Natural Science and Mathematics, Ural Federal University, Yekaterinburg, 620002, Russia
| | - Arivalagan Pugazhendhi
- School of Engineering, Lebanese American University, Byblos, Lebanon; University Centre for Research & Development, Department of Civil Engineering, Chandigarh University, Mohali-140103, India.
| |
Collapse
|
6
|
Zhang Y, Li Y, Yin P, Han W. Synthesis by adding CTAB and characterization of Ag@CuO@rGO nanocomposite with a novel core-shell crystal sugar structure and its application in supercapacitors. RSC Adv 2023; 13:19803-19812. [PMID: 37404319 PMCID: PMC10315995 DOI: 10.1039/d3ra03025c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2023] [Accepted: 06/07/2023] [Indexed: 07/06/2023] Open
Abstract
In this study, we successfully synthesized Ag@CuO@rGO (rGO wrapped around Ag/CuO) nanocomposites using AgNO3, Cu(NO)32, and NaOH as raw materials and particularly treated CTAB as a template by chemical precipitation, hydrothermal synthesis, and subsequent high-temperature calcination processes. In addition, transmission electron microscopy (TEM) images revealed that the prepared products appeared to have a mixed structure. The results indicated that the best choice was CuO wrapped around Ag nanoparticles to form a core-shell crystal structure, and the crystal particles were arranged similarly to form an icing sugar block structure and were tightly wrapped by rGO. Moreover, the electrochemical test results demonstrated that Ag@CuO@rGO composite electrode material exhibited high pseudocapacitance performance; the material had a high specific capacity of 1453 F g-1 at a current density of 2.5 mA cm-2, and the charging and discharging cycles remained constant up to 2000 times, indicating that the introduction of Ag improved the cycling stability and reversibility of the CuO@rGO electrode material and increased its specific capacitance, leading to the increase in the specific capacitance of supercapacitors. Therefore, the above results strongly support the application of Ag@CuO@rGO in optotronic devices.
Collapse
Affiliation(s)
- Yuxin Zhang
- School of Materials Science and Engineering, North China University of Water Resources and Electric Power Zhengzhou 450045 China
| | - Yong Li
- School of Materials Science and Engineering, North China University of Water Resources and Electric Power Zhengzhou 450045 China
| | - Pengchong Yin
- School of Materials Science and Engineering, North China University of Water Resources and Electric Power Zhengzhou 450045 China
| | - Weizhong Han
- School of Materials Science and Engineering, North China University of Water Resources and Electric Power Zhengzhou 450045 China
- School of Materials Science and Engineering, Xi'an Jiaotong University Xi'an 710049 China
| |
Collapse
|
7
|
Bhaduri SN, Ghosh D, Debnath S, Biswas R, Chatterjee PB, Biswas P. Copper(II)-Incorporated Porphyrin-Based Porous Organic Polymer for a Nonenzymatic Electrochemical Glucose Sensor. Inorg Chem 2023; 62:4136-4146. [PMID: 36862998 DOI: 10.1021/acs.inorgchem.2c04072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/04/2023]
Abstract
To date, the fabrication of multifunctional nanoplatforms based on a porous organic polymer for electrochemical sensing of biorelevant molecules has received considerable attention in the search for a more active, robust, and sensitive electrocatalyst. Here, in this report, we have developed a new porous organic polymer based on porphyrin (TEG-POR) from a polycondensation reaction between a triethylene glycol-linked dialdehyde and pyrrole. The Cu(II) complex of the polymer Cu-TEG-POR shows high sensitivity and a low detection limit for glucose electro-oxidation in an alkaline medium. The characterization of the as-synthesized polymer was done by thermogravimetric analysis (TGA), scanning electron microscopy (SEM), transmission electron microscopy (TEM), Fourier transform infrared (FTIR) spectroscopy, and 13C CP-MAS solid-state NMR. The N2 adsorption/desorption isotherm was carried out at 77 K to analyze the porous property. TEG-POR and Cu-TEG-POR both show excellent thermal stability. The Cu-TEG-POR-modified GC electrode shows a low detection limit (LOD) value of 0.9 μM and a wide linear range (0.001-1.3 mM) with a sensitivity of 415.8 μA mM-1 cm-2 toward electrochemical glucose sensing. The interference of the modified electrode from ascorbic acid, dopamine, NaCl, uric acid, fructose, sucrose, and cysteine was insignificant. Cu-TEG-POR exhibits acceptable recovery for blood glucose detection (97.25-104%), suggesting its scope in the future for selective and sensitive nonenzymatic glucose detection in human blood.
Collapse
Affiliation(s)
- Samanka Narayan Bhaduri
- Department of Chemistry, Indian Institute of Engineering Science and Technology, Howrah 711103, West Bengal, India
| | - Debojit Ghosh
- Department of Chemistry, Indian Institute of Engineering Science and Technology, Howrah 711103, West Bengal, India
| | - Snehasish Debnath
- Analytical & Environmental Science Division and Centralized Instrument Facility, CSIR-CSMCRI, G. B. Marg, Bhavnagar 364002, Gujarat, India
| | - Rima Biswas
- Department of Chemistry, Indian Institute of Engineering Science and Technology, Howrah 711103, West Bengal, India
| | - Pabitra B Chatterjee
- Analytical & Environmental Science Division and Centralized Instrument Facility, CSIR-CSMCRI, G. B. Marg, Bhavnagar 364002, Gujarat, India.,Academy of Scientific and Innovative Research (AcSIR), Ghaziabad 201002, India
| | - Papu Biswas
- Department of Chemistry, Indian Institute of Engineering Science and Technology, Howrah 711103, West Bengal, India
| |
Collapse
|
8
|
Tetyana P, Mphuthi N, Jijana AN, Moloto N, Shumbula PM, Skepu A, Vilakazi LS, Sikhwivhilu L. Synthesis, Characterization, and Electrochemical Evaluation of Copper Sulfide Nanoparticles and Their Application for Non-Enzymatic Glucose Detection in Blood Samples. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:481. [PMID: 36770442 PMCID: PMC9919628 DOI: 10.3390/nano13030481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 08/16/2022] [Accepted: 08/26/2022] [Indexed: 06/18/2023]
Abstract
Glutathione-capped copper sulfide (CuxSy) nanoparticles with two different average sizes were successfully achieved by using a simple reduction process that involves only changing the reaction temperature. Temperature-induced changes in the size of CuxSy nanoparticles resulted in particles with different optical, morphological, and electrochemical properties. The dependence of electrochemical sensing properties on the sizes of CuxSy nanoparticles was studied by using voltammetric and amperometric techniques. The spherical CuxSy nanoparticles with the average particle size of 25 ± 0.6 nm were found to be highly conductive as compared to CuxSy nanoparticles with the average particle size of 4.5 ± 0.2 nm. The spherical CuxSy nanoparticles exhibited a low bandgap energy (Eg) of 1.87 eV, resulting in superior electrochemical properties and improved electron transfer during glucose detection. The sensor showed a very good electrocatalytic activity toward glucose molecules in the presence of interference species such as uric acid (UA), ascorbic acid (AA), fructose, sodium chloride, and sucrose. These species are often present in low concentrations in the blood. The sensor demonstrated an excellent dynamic linear range between 0.2 to 16 mM, detection limit of 0.2 mM, and sensitivity of 0.013 mA/mM. The applicability of the developed sensor for real field determination of glucose was demonstrated by use of spiked blood samples, which confirmed that the developed sensor had great potential for real analysis of blood glucose levels.
Collapse
Affiliation(s)
- Phumlani Tetyana
- DSI/Mintek Nanotechnology Innovation Centre, Advanced Materials Division, Mintek, Private Bag X3015, Randburg 2125, South Africa
- Department of Chemistry, University of Witwatersrand, Private Bag X3, Braamfontein 2050, South Africa
| | - Ntsoaki Mphuthi
- DSI/Mintek Nanotechnology Innovation Centre, Advanced Materials Division, Mintek, Private Bag X3015, Randburg 2125, South Africa
- Department of Chemical Sciences, University of Johannesburg, Doornfontein 2028, South Africa
| | - Abongile Nwabisa Jijana
- DSI/Mintek Nanotechnology Innovation Centre, Advanced Materials Division, Mintek, Private Bag X3015, Randburg 2125, South Africa
| | - Nosipho Moloto
- Department of Chemistry, University of Witwatersrand, Private Bag X3, Braamfontein 2050, South Africa
| | - Poslet Morgan Shumbula
- Department of Chemistry, University of Limpopo, Private Bag X1106, Sovenga 0727, South Africa
| | - Amanda Skepu
- Next Generation Health, Division 1, CSIR, Meiring Naude Road, Brummeria, Pretoria 0001, South Africa
| | - Lea Sibulelo Vilakazi
- DSI/Mintek Nanotechnology Innovation Centre, Advanced Materials Division, Mintek, Private Bag X3015, Randburg 2125, South Africa
| | - Lucky Sikhwivhilu
- DSI/Mintek Nanotechnology Innovation Centre, Advanced Materials Division, Mintek, Private Bag X3015, Randburg 2125, South Africa
- Department of Chemistry, Faculty of Science, Engineering and Agriculture, University of Venda, Private Bag X5050, Thohoyandou 0950, South Africa
| |
Collapse
|
9
|
Walton RI. Solvothermal and hydrothermal methods for preparative solid-state chemistry. COMPREHENSIVE INORGANIC CHEMISTRY III 2023:40-110. [DOI: 10.1016/b978-0-12-823144-9.00068-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2025]
|
10
|
State (Rosoiu) S, Enache LB, Potorac P, Prodana M, Enachescu M. Synthesis of Copper Nanostructures for Non-Enzymatic Glucose Sensors via Direct-Current Magnetron Sputtering. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:4144. [PMID: 36500774 PMCID: PMC9739512 DOI: 10.3390/nano12234144] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 11/17/2022] [Accepted: 11/21/2022] [Indexed: 06/17/2023]
Abstract
In this paper, Cu nanocolumnar structure electrodes are synthetized using a clean and easy-to-scale-up direct-current magnetron sputtering (DC-MS) technique for non-enzymatic glucose sensing. The nanocolumnar structure increases the active surface area of the deposit, with the nanocolumns showing a mean size diameter of 121.0 nm ± 27.2 and a length of 2.52 µm ± 0.23. A scanning transmission electron (STEM) analysis shows the presence of Cu and a small amount of Cu2O. The behavior of the electrodes in alkaline environments and the electrochemical affinity of the Cu nanocolumns (CuNCs) towards the electro-oxidation of glucose are investigated using cyclic voltammetry (CV). After performing CV in NaOH solution, the columnar structures present corrosion products containing Cu2O, as revealed by STEM and X-ray diffraction (XRD) analyses. The amperometric responses of the CuNCs to the successive addition of glucose show a linear range up to 2 mM and a limit of detection of 5.2 µM. Furthermore, the electrodes are free from chloride poisoning, and they are insensitive to dopamine, uric acid, ascorbic acid, and acetaminophen at their physiological concentrations.
Collapse
Affiliation(s)
- Sabrina State (Rosoiu)
- Center for Surface Science and Nanotechnology, Politehnica University of Bucharest, Splaiul Independentei 313, 060042 Bucharest, Romania
| | - Laura-Bianca Enache
- Center for Surface Science and Nanotechnology, Politehnica University of Bucharest, Splaiul Independentei 313, 060042 Bucharest, Romania
| | - Pavel Potorac
- Center for Surface Science and Nanotechnology, Politehnica University of Bucharest, Splaiul Independentei 313, 060042 Bucharest, Romania
| | - Mariana Prodana
- Department of General Chemistry, Faculty of Applied Chemistry and Materials Science, Politehnica University of Bucharest, Splaiul Independentei 313, 060042 Bucharest, Romania
| | - Marius Enachescu
- Center for Surface Science and Nanotechnology, Politehnica University of Bucharest, Splaiul Independentei 313, 060042 Bucharest, Romania
- Academy of Romanian Scientists, Splaiul Independentei 54, 050094 Bucharest, Romania
| |
Collapse
|
11
|
Cao X. CuO Nanowires Fabricated by Thermal Oxidation of Cu Foils towards Electrochemical Detection of Glucose. MICROMACHINES 2022; 13:2010. [PMID: 36422439 PMCID: PMC9692939 DOI: 10.3390/mi13112010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 10/28/2022] [Accepted: 11/15/2022] [Indexed: 06/16/2023]
Abstract
In view of the various stability issues and high cost of enzymatic glucose biosensors, non-enzymatic biosensors have received great attention in recent research and development. Copper oxide (CuO) nanowires (NWs) were fabricated on Cu foil substrate using a simple thermal oxidation method. The phase and morphology of the CuO NWs could be controlled by synthesis temperature. Variation in oxidation states enables CuO NWs to form Cu (III) species, which is crucial in catalysing the eletro-oxidation of glucose. The Cu-based metal/oxide composite electrode works as a non-enzymatic biosensor that adapts to the fast, dynamic change in glucose concentration, with a low saturation concentration (~0.7 mM) and a lower detection limit of 0.1 mM, making CuO NWs an excellent sensor towards impaired fasting glucose. The simplicity, cost-effectiveness and non-toxicity features of this study might make a way for potentially scalable application in glucose biosensing.
Collapse
Affiliation(s)
- Xun Cao
- School of Materials Science and Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore
| |
Collapse
|
12
|
Room-temperature fabrication of a heterostructure Cu2O@CuO nanosheet electrocatalyst for non-enzymatic detection of glucose and H2O2. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2022.116874] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
13
|
Barbee B, Muchharla B, Adedeji A, Karoui A, Kumar Sadasivuni K, Sha MS, Abdullah AM, Slaughter G, Kumar B. Cu and Ni Co-sputtered heteroatomic thin film for enhanced nonenzymatic glucose detection. Sci Rep 2022; 12:7507. [PMID: 35525846 PMCID: PMC9079054 DOI: 10.1038/s41598-022-11563-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2022] [Accepted: 04/26/2022] [Indexed: 11/30/2022] Open
Abstract
In this work, we report a wafer-scale and chemical-free fabrication of nickel (Ni) and copper (Cu) heteroatomic Cu–Ni thin films using RF magnetron sputtering technique for non-enzymatic glucose sensing application. The as-prepared wafer-scale Cu–Ni thin films exhibits excellent electrocatalytic activity toward glucose oxidation with a 1.86 μM detection limit in the range of 0.01 mM to 20 mM range. The Cu–Ni film shows 1.3- and 5.4-times higher glucose oxidation activity in comparison to the Cu and Ni electrodes, respectively. The improved electrocatalytic activity is attributed to the synergistic effect of the bimetallic catalyst and high density of grain boundaries. The Cu–Ni electrodes also possessed excellent anti-interference characteristics. These results indicate that Cu–Ni heteroatomic thin film can be a potential candidate for the development of non-enzymatic glucose biosensor because of its chemical free synthesis, excellent reproducibility, reusability, and long-term stability.
Collapse
Affiliation(s)
- Brianna Barbee
- Department of Mathematics, Computer Science and Engineering Technology, Elizabeth City State University, Elizabeth City, NC, 27909, USA
| | - Baleeswaraiah Muchharla
- Department of Mathematics, Computer Science and Engineering Technology, Elizabeth City State University, Elizabeth City, NC, 27909, USA
| | - Adetayo Adedeji
- Department of Natural Sciences, Elizabeth City State University, Elizabeth City, NC, 27909, USA
| | - Abdennaceur Karoui
- Center for Research Excellence in Science and Technology (CREST), Department of Mathematics and Physics, North Carolina Central University, Durham, NC, 27707, USA
| | | | - Mizaj Shabil Sha
- Center for Advanced Materials, Qatar University, 2713, Doha, Qatar
| | | | - Gymama Slaughter
- Center for Bioelectronics, Old Dominion University, 4211 Monarch Way, Norfolk, VA, 23508, USA
| | - Bijandra Kumar
- Department of Mathematics, Computer Science and Engineering Technology, Elizabeth City State University, Elizabeth City, NC, 27909, USA.
| |
Collapse
|
14
|
Figiela M, Wysokowski M, Stanisz E, Hao D, Ni BJ, Stepniak I. Highly sensitive, fast response and selective glucose detection based on CuO/nitrogen‐doped carbon non‐enzymatic sensor. ELECTROANAL 2022. [DOI: 10.1002/elan.202100475] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
| | | | | | - Derek Hao
- University of Technology Sydney AUSTRALIA
| | | | | |
Collapse
|
15
|
Liu X, Yang C, Yang W, Lin J, Zhou X, Li Y. Cu nanoplates with “clean surface”: synthesis and their enhanced biosensors performance. J IND ENG CHEM 2022. [DOI: 10.1016/j.jiec.2022.01.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
16
|
Naikoo GA, Awan T, Salim H, Arshad F, Hassan IU, Pedram MZ, Ahmed W, Faruck HL, Aljabali AAA, Mishra V, Serrano‐Aroca Á, Goyal R, Negi P, Birkett M, Nasef MM, Charbe NB, Bakshi HA, Tambuwala MM. Fourth-generation glucose sensors composed of copper nanostructures for diabetes management: A critical review. Bioeng Transl Med 2022; 7:e10248. [PMID: 35111949 PMCID: PMC8780923 DOI: 10.1002/btm2.10248] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 08/10/2021] [Accepted: 08/13/2021] [Indexed: 01/31/2023] Open
Abstract
More than five decades have been invested in understanding glucose biosensors. Yet, this immensely versatile field has continued to gain attention from the scientific world to better understand and diagnose diabetes. However, such extensive work done to improve glucose sensing devices has still not yielded desirable results. Drawbacks like the necessity of the invasive finger-pricking step and the lack of optimization of diagnostic interventions still need to be considered to improve the testing process of diabetic patients. To upgrade the glucose-sensing devices and reduce the number of intermediary steps during glucose measurement, fourth-generation glucose sensors (FGGS) have been introduced. These sensors, made using robust electrocatalytic copper nanostructures, improve diagnostic efficiency and cost-effectiveness. This review aims to present the essential scientific progress in copper nanostructure-based FGGS in the past 10 years (2010 to present). After a short introduction, we presented the working principles of these sensors. We then highlighted the importance of copper nanostructures as advanced electrode materials to develop reliable real-time FGGS. Finally, we cover the advantages, shortcomings, and prospects for developing highly sensitive, stable, and specific FGGS.
Collapse
Affiliation(s)
- Gowhar A. Naikoo
- Department of Mathematics and SciencesCollege of Arts and Applied Sciences, Dhofar UniversitySalalahOman
| | - Tasbiha Awan
- Department of Mathematics and SciencesCollege of Arts and Applied Sciences, Dhofar UniversitySalalahOman
| | - Hiba Salim
- Department of Mathematics and SciencesCollege of Arts and Applied Sciences, Dhofar UniversitySalalahOman
| | - Fareeha Arshad
- Department of BiochemistryAligarh Muslim UniversityAligarhIndia
| | | | - Mona Zamani Pedram
- Faculty of Mechanical Engineering—Energy DivisionK.N. Toosi University of TechnologyTehranIran
| | - Waqar Ahmed
- School of Mathematics and PhysicsCollege of Science, University of LincolnLincolnUK
| | | | - Alaa A. A. Aljabali
- Departmnt of Pharmaceutics and Pharmaceutical TechnologyYarmouk UniversityIrbidJordan
| | - Vijay Mishra
- School of Pharmaceutical SciencesLovely Professional UniversityPhagwaraPunjabIndia
| | - Ángel Serrano‐Aroca
- Biomaterials and Bioengineering LabTranslational Research Centre San Alberto Magno, Catholic University of Valencia San Vicente MártirValenciaSpain
| | - Rohit Goyal
- School of Pharmaceutical SciencesShoolini University of Biotechnology and Management SciencesSolanIndia
| | - Poonam Negi
- School of Pharmaceutical SciencesShoolini University of Biotechnology and Management SciencesSolanIndia
| | - Martin Birkett
- Department of Mechanical and Construction EngineeringNorthumbria UniversityNewcastle upon TyneUK
| | - Mohamed M. Nasef
- Department of PharmacySchool of Applied Science, University of HuddersfieldUK
| | - Nitin B. Charbe
- Department of Pharmaceutical SciencesRangel College of Pharmacy, Texas A&M UniversityKingsvilleTexasUSA
| | - Hamid A. Bakshi
- School of Pharmacy and Pharmaceutical ScienceUlster UniversityColeraineUK
| | | |
Collapse
|
17
|
Nonenzymatic electrochemical sensors via Cu native oxides (CuNOx) for sweat glucose monitoring. SENSING AND BIO-SENSING RESEARCH 2021. [DOI: 10.1016/j.sbsr.2021.100453] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
|
18
|
Non-enzymatic and rapid detection of glucose on PVA-CuO thin film using ARDUINO UNO based capacitance measurement unit. Biomed Microdevices 2021; 23:36. [PMID: 34259948 DOI: 10.1007/s10544-021-00568-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/08/2021] [Indexed: 10/20/2022]
Abstract
Glucose measurement is one of the essential health monitoring practices for maintaining blood sugar levels. Here, we have fabricated a highly specific capacitive nano-sensor for non-enzymatic glucose detection. Capacitance measurements were carried out on polyvinyl alcohol capped copper oxide (PVA-CuO) thin films on indium tin oxide (ITO) coated glass using ARDUINO UNO. The capacitance study shows a decrease in capacitance with an increase in glucose concentrations. The applicability in real samples was performed by studying the glucose in the presence of fetal bovine serum. Most commonly found interfering agents were used for interference studies, which confirmed the capacitive nano-sensor specificity. The system was further checked for repeatability up to six readings and reproducibility up to 5 chips. The shelf-life study showed stability for four weeks of a chip. These studies indicate that this capacitance-based measurement unit can be used for reliable, rapid, and non-enzymatic detection of glucose in real sample.
Collapse
|
19
|
Yuan K, Zhang Y, Huang S, Yang S, Zhao S, Liu F, Peng Q, Zhao Y, Zhang G, Fan J, Zang G. Copper Nanoflowers on Carbon Cloth as a Flexible Electrode Toward Both Enzymeless Electrocatalytic Glucose and H
2
O
2. ELECTROANAL 2021. [DOI: 10.1002/elan.202100029] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Kun Yuan
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Yuchan Zhang
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Shihao Huang
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Shengfei Yang
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Shuang Zhao
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
- Key Laboratory for Biorheological Science and Technology of Ministry of Education State and Local Joint Engineering Laboratory for Vascular Implants Bioengineering College of Chongqing University Chongqing 400030 China
| | - Fangxin Liu
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Qianyu Peng
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Yinping Zhao
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Guangyuan Zhang
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Jingchuan Fan
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| | - Guangchao Zang
- Laboratory of Tissue and Cell Biology Lab Teaching & Management Center Chongqing Medical University Chongqing 400016 P.R. China
| |
Collapse
|
20
|
Peng Q, Zhang Y, Yang S, Yuwen T, Liu Y, Fan J, Zang G. Glucose determination behaviour of gold microspheres-electrodeposited carbon cloth flexible electrodes in neutral media. Anal Chim Acta 2021; 1159:338442. [PMID: 33867044 DOI: 10.1016/j.aca.2021.338442] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2021] [Revised: 03/16/2021] [Accepted: 03/18/2021] [Indexed: 11/30/2022]
Abstract
Despite numerous advances in the field of nonenzymatic glucose detection, monitoring glucose in physiological applications is still a challenge and is mostly limited to electrode surface modification. This study proposes a simple method for electrodepositing cotton-like gold microspheres (CGMs) on a carbon cloth (CC) flexible electrode, with the potential for the functional supporting substrate to monitor glucose in a neutral environment. It was demonstrated that the voltammetric response of glucose oxidation increased with increases in glucose concentration in the 3D functional flexible substrate; moreover, the amperometric response of glucose oxidation increased over time. The results indicate that the functional flexible electrode-made of gold microspheres-based carbon cloth with a predefined geometry and pore-architecture network to promote the medium-permeation and synergetic effects between CGMs and CC-can be a suitable platform for measuring glucose variation in environments with neutral pH. This is particularly relevant because the oxygen-containing functional groups on the CC surface increase the dehydrogenation rate of glucose oxidation in neutral phosphate-buffered saline.
Collapse
Affiliation(s)
- Qianyu Peng
- Institute of Life Science, And Laboratory of Tissue and Cell Biology, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, 400016, China
| | - Yuchan Zhang
- Institute of Life Science, And Laboratory of Tissue and Cell Biology, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, 400016, China
| | - Shengfei Yang
- Institute of Life Science, And Laboratory of Tissue and Cell Biology, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, 400016, China
| | - Tianyi Yuwen
- Institute of Life Science, And Laboratory of Tissue and Cell Biology, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, 400016, China
| | - Yangkun Liu
- Institute of Life Science, And Laboratory of Tissue and Cell Biology, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, 400016, China
| | - Jingchuan Fan
- Institute of Life Science, And Laboratory of Tissue and Cell Biology, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, 400016, China
| | - Guangchao Zang
- Institute of Life Science, And Laboratory of Tissue and Cell Biology, Lab Teaching & Management Center, Chongqing Medical University, Chongqing, 400016, China.
| |
Collapse
|
21
|
Apetrei RM, Camurlu P. Facile copper-based nanofibrous matrix for glucose sensing: Eenzymatic vs. non-enzymatic. Bioelectrochemistry 2021; 140:107751. [PMID: 33667903 DOI: 10.1016/j.bioelechem.2021.107751] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 01/17/2021] [Accepted: 01/25/2021] [Indexed: 11/28/2022]
Abstract
The current study aims to provide a valid comparison between glucose detection efficiency with an enzymatic and a non-enzymatic sensing platform. A low-cost nano-matrix for glucose sensing was developed by drop-coating copper nanoparticles (Cu NPs) onto a polyacrylonitrile (PAN) electrospun nanofibrous assembly. The PAN NFs/Cu NPs matrix was optimized regarding electrospinning time and Cu NPs content and employed as a non-enzymatic sensor or further modified by cross-linking of glucose oxidase (GOD) for the development of an enzymatic sensor. The non-enzymatic glucose sensor was three times more sensitive (300 mAM-1cm-2) than the enzymatic one (81 mAM-1cm-2) with similar limit of detection values (5.9 and 5.6 µM, respectively). Incorporation of MWCNTs improved both the LOD (3.3 µM) and the operational stability of the non-enzymatic configuration (RSD 7.3%). The interference effect proved insignificant for the enzymatic sensor due to the innate catalytic selectivity whilst the non-enzymatic sensor acquired selectivity due to the nanofibrous PAN matrix and Nafion coating. The non-enzymatic PAN NFs/Cu NPs sensor was chosen for the detection of glucose in real blood serum samples whilst the PAN NFs/Cu NPs/GOD sensor was applied for glucose detection in fruit juices, both proving recovery results close to 100%.
Collapse
Affiliation(s)
- Roxana-Mihaela Apetrei
- Akdeniz University, Department of Chemistry, 07058 Antalya, Turkey; 'Dunarea de Jos' University of Galati, Domneasca Street, 47, Galati RO-800008, Romania
| | - Pinar Camurlu
- Akdeniz University, Department of Chemistry, 07058 Antalya, Turkey.
| |
Collapse
|
22
|
Highly sensitive non-enzymatic electrochemical glucose sensor based on dumbbell-shaped double-shelled hollow nanoporous CuO/ZnO microstructures. Sci Rep 2021; 11:344. [PMID: 33431992 PMCID: PMC7801383 DOI: 10.1038/s41598-020-79460-2] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2020] [Accepted: 12/08/2020] [Indexed: 01/29/2023] Open
Abstract
A high-performance non-enzymatic glucose sensor based on hybrid metal-oxides is proposed. Dumbbell-shaped double-shelled hollow nanoporous CuO/ZnO microstructures (CuO/ZnO-DSDSHNM) were prepared via the hydrothermal method using pluronic F-127 as a surfactant. This structure is studied by various physicochemical characterizations such as scanning electron microscopy, X-ray diffraction spectroscopy, inductively coupled plasma atomic emission spectroscopy, elemental mapping techniques, X-ray photoelectron spectroscopy, and transmission electron microscopy. This unique CuO/ZnO-DSDSHNM provides both a large surface area and an easy penetrable structure facilitating improved electrochemical reactivity toward glucose oxidation. The prepared CuO/ZnO-DSDSHNM was used over the glassy carbon electrode (GCE) as the active material for glucose detection and then coated by Nafion to provide the proposed Nafion/CuO/ZnO-DSDSHNM/GCE. The fabricated glucose sensor exhibits an extremely wide dynamic range from 500 nM to 100 mM, a sensitivity of 1536.80 µA mM-1 cm-2, a low limit of detection of 357.5 nM, and a short response time of 1.60 s. The proposed sensor also showed long-term stability, good reproducibility, favorable repeatability, excellent selectivity, and satisfactory applicability for glucose detection in human serum samples. The achieved high-performance glucose sensing based on Nafion/CuO/ZnO-DSDSHNM/GCE shows that both the material synthesis and the sensor fabrication methods have been promising and they can be used in future researches.
Collapse
|
23
|
Fang L, Cai Y, Huang B, Cao Q, Zhu Q, Tu T, Ye X, Liang B. A highly sensitive nonenzymatic glucose sensor based on Cu/Cu2O composite nanoparticles decorated single carbon fiber. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2020.114888] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
|
24
|
Functional nanostructured metal oxides and its hybrid electrodes – Recent advancements in electrochemical biosensing applications. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105522] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
25
|
Highly Sensitive Non-Enzymatic Detection of Glucose at MWCNT-CuBTC Composite Electrode. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10238419] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
A novel electrochemical glucose sensor was developed, based on a multiwall carbon nanotubes (MWCNTs)-copper-1,3,5-benzenetricarboxylic acid (CuBTC)-epoxy composite electrode, named MWCNT-CuBTC. The electrode nanocomposite was prepared by a two-roll mill procedure and characterized morphostructurally by scanning electron microscopy (SEM). The CuBTC formed defined crystals with a wide size distribution, which were well dispersed and embedded in the MWCNTs. Its electrical conductivity was determined by four-point probe contact (DC) conductivity measurements. The electroactive surface area, determined using cyclic voltammetry (CV), was found to be 6.9 times higher than the geometrical one. The results of the electrochemical measurements using CV, linear sweep voltammetry (LSV), differential pulse voltammetry (DPV), chronoamperometry (CA) and multiple pulse amperometry (MPA) showed that the MWCNT-CuBTC composite electrode displayed high electrocatalytic activity toward the oxidation of glucose and, as a consequence, very high sensitivity. The best sensitivity of 14,949 µAmM−1cm−1 was reached using MPA at the potential value of 0.6 V/SCE, which was much higher in comparison with other copper-based electrodes reported in the literature. The good analytical performance, low cost and simple preparation method make this novel electrode material promising for the development of an effective glucose sensor.
Collapse
|
26
|
Chandrasekaran N, Matheswaran M. Unique Nonenzymatic Glucose Sensor Using a Hollow-Shelled Triple Oxide Mn-Cu-Al Nanocomposite. ACS OMEGA 2020; 5:23502-23509. [PMID: 32984668 PMCID: PMC7512457 DOI: 10.1021/acsomega.0c00417] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Accepted: 04/14/2020] [Indexed: 06/11/2023]
Abstract
Glucose monitoring devices for diabetes mellitus, which is a worldwide significant health issue, have attracted attention of many researchers. Herein, we report a hollow Mn-Cu-Al oxide nanocomposite (HMCA) by a microwave-assisted technique showing excellent sensing abilities toward glucose. Also, it possesses a superb supercapacitor activity described in our previous paper. The sensitivity value of the nanocomposite is 2.194 mA mM-1 cm-2 with a low detection limit of 0.43 μM (S/N = 3). The high sensitivity and low detection limit were the results of the large surface area of the nanocomposite and the redox nature of CuO and MnO2. It shows a selective detection of glucose levels in blood serum. The hollow nanocomposite has been useful for monitoring the glucose level in blood serum and holds great potential for diabetes mellitus and clinical diagnosis.
Collapse
Affiliation(s)
| | - Manickam Matheswaran
- Department
of Chemical Engineering, National Institute
of Technology Tiruchirappalli, Tiruchirappalli 620015, India
| |
Collapse
|
27
|
Haghparas Z, Kordrostami Z, Sorouri M, Rajabzadeh M, Khalifeh R. Fabrication of Non-enzymatic Electrochemical Glucose Sensor Based on Nano-copper Oxide Micro Hollow-spheres. BIOTECHNOL BIOPROC E 2020. [DOI: 10.1007/s12257-020-0058-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
28
|
Taşaltın N, Taşaltın C, Karakuş S, Kilislioğlu A. Cu core shell nanosphere based electrochemical non-enzymatic sensing of glucose. INORG CHEM COMMUN 2020. [DOI: 10.1016/j.inoche.2020.107991] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
29
|
Mishra AK, Jarwal DK, Mukherjee B, Kumar A, Ratan S, Tripathy MR, Jit S. Au nanoparticles modified CuO nanowireelectrode based non-enzymatic glucose detection with improved linearity. Sci Rep 2020; 10:11451. [PMID: 32651423 PMCID: PMC7351779 DOI: 10.1038/s41598-020-67986-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2020] [Accepted: 06/01/2020] [Indexed: 11/18/2022] Open
Abstract
This paper explores gold nanoparticle (GNP) modified copper oxide nanowires(CuO NWs)based electrode grown on copper foil for non-enzymatic glucose detection in a wide linear ranging up to 31.06 mM, and 44.36 mM at 0.5 M NaOH and 1 M NaOH concentrations. The proposed electrode can be used to detect a very low glucose concentration of 0.3 µM with a high linearity range of 44.36mM and sensitivity of 1591.44 µA mM-1 cm-2. The electrode is fabricated by first synthesizing Cu (OH)2 NWs on a copper foil by chemical etching method and then heat treatment is performed to convert Cu (OH)2 NWs into CuO NWs. The GNPs are deposited on CuO NWs to enhance the effective surface-to-volume ratio of the electrode with improved catalytic activity. The surface morphology has been investigated by XRD, XPS, FE-SEM and HR-TEM analysis. The proposed sensor is expected to detect low-level of glucose in urine, and saliva. At the same time, it can also be used to measure extremely high sugar levels (i.e. hyperglycemia) of ~ 806.5454 mg/dl. The proposed sensor is also capable of detecting glucose after multiple bending of the GNP modified CuO NWs electrode. The proposed device is also used to detect the blood sugar level in human being and it is found that this sensor's result is highly accurate and reliable.
Collapse
Affiliation(s)
- Ashwini Kumar Mishra
- Department of Electronics Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, 221005, India
| | - Deepak Kumar Jarwal
- Department of Electronics Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, 221005, India
| | - Bratindranath Mukherjee
- Department of Metallurgical Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, India
| | - Amit Kumar
- Department of Electronics Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, 221005, India
| | - Smrity Ratan
- Department of Electronics Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, 221005, India
| | - Manas Ranjan Tripathy
- Department of Electronics Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, 221005, India
| | - Satyabrata Jit
- Department of Electronics Engineering, Indian Institute of Technology (BHU) Varanasi, Varanasi, 221005, India.
| |
Collapse
|
30
|
Ayaz S, Karakaya S, Emir G, Dilgin DG, Dilgin Y. A novel enzyme-free FI-amperometric glucose biosensor at Cu nanoparticles modified graphite pencil electrode. Microchem J 2020. [DOI: 10.1016/j.microc.2019.104586] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
31
|
CeO2-based heterostructure nanocomposite for electrochemical determination of l-cysteine biomolecule. INORG CHEM COMMUN 2020. [DOI: 10.1016/j.inoche.2020.107793] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
|
32
|
Ultrathin CuxO nanoflakes anchored Cu2O nanoarray for high-performance non-enzymatic glucose sensor. J Solid State Electrochem 2020. [DOI: 10.1007/s10008-019-04472-6] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
33
|
Gold-nanourchin seeded single-walled carbon nanotube on voltammetry sensor for diagnosing neurogenerative Parkinson’s disease. Anal Chim Acta 2020; 1094:142-150. [DOI: 10.1016/j.aca.2019.10.012] [Citation(s) in RCA: 41] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2019] [Revised: 10/04/2019] [Accepted: 10/08/2019] [Indexed: 01/02/2023]
|
34
|
Cu(I) Coordination Complex Precursor for Randomized CuO x Microarray Loaded on Carbon Nanofiber with Excellent Electrocatalytic Performance for Electrochemical Glucose Detection. SENSORS 2019; 19:s19245353. [PMID: 31817245 PMCID: PMC6960723 DOI: 10.3390/s19245353] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/29/2019] [Revised: 11/29/2019] [Accepted: 12/01/2019] [Indexed: 12/21/2022]
Abstract
A homoleptic ionic Cu(I) coordination complex that was based on 2,2′-biquinoline ligand functionalized with long alkyl chains (Cu(I)–C18) was used as a precursor to modify a carbon nanofiber paste electrode (Cu–C18/CNF). Randomized copper oxide microelectrode arrays dispersed within carbon nanofiber paste (CuOx/CNF) were obtained by electrochemical treatment of Cu–C18/CNF while using cyclic voltammetry (CV). The CuOx/CNF exhibited high electrocatalytic activity towards glucose oxidation at +0.6 V and +1.2 V vs. Ag/AgCl. Infrared Spectroscopy (FTIR) and scanning electron microscopy (SEM) characterized the electrodes composition. Cyclic voltammetry (CV), square wave-voltammetry (SWV), and multiple-pulsed amperometry (MPA) techniques provided optimized conditions for glucose oxidation and detection. A preconcentration step that involved 10 minutes accumulation at open circuit potential before SWV running led to the lowest limit of detection and the highest sensitivity for glucose detection (5419.77 µA·mM−1·cm−2 at + 1.1 V vs. Ag/AgCl) vs. Cu-based electrodes reported to date in literature.
Collapse
|
35
|
Zheng S, Zhang H, Lakshmipriya T, Gopinath SCB, Yang N. Gold Nanorod Integrated Electrochemical Sensing for Hyperglycaemia on Interdigitated Electrode. BIOMED RESEARCH INTERNATIONAL 2019; 2019:9726967. [PMID: 31380444 PMCID: PMC6662476 DOI: 10.1155/2019/9726967] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2019] [Revised: 06/30/2019] [Accepted: 07/03/2019] [Indexed: 11/17/2022]
Abstract
Gestational diabetes (hyperglycaemia) is an elevated blood sugar level diagnosed during the period of pregnancy and affects the baby's health. Hyperglycaemia has been found within the gestational weeks between 24 and 28, and the foetus has also the possibility of getting out prior to this test frame; it causes excessive birth weight, early birth, low-blood sugar level, respiratory distress syndrome, and type-2 diabetes to the mother. It creates a mandatory situation to identify the hyperglycaemia at least during the pregnancy weeks from 18 to 20. Further, a continuous monitoring of the level of glucose is necessary for the proper delivery. In this work, a method is introduced for glucose detection at 0.06 mg/mL, assisted by gold nanorod (GNR)-conjugated glucose oxidase (GOx) on interdigitated electrode sensor. In the absence of GNR, GOx shows the limit of glucose detection to be 0.25 mg/mL. Moreover, with GOx-GNR the reactions of all the glucose concentrations have recorded higher levels of the current from the baseline. With the specificity analysis, it was found that the glucose only reacts with GOx-GNR and discriminates other sugars efficiently. This method of detection is useful to diagnose and continuously monitor the glucose level during the pregnancy period.
Collapse
Affiliation(s)
- Shumin Zheng
- Department of Obstetrics, Dezhou People's Hospital, No. 1166 Dongfanghong West Road, Dezhou, Shandong Province, 253014, China
| | - Hong Zhang
- Department of Obstetrics, Dezhou People's Hospital, No. 1166 Dongfanghong West Road, Dezhou, Shandong Province, 253014, China
| | - Thangavel Lakshmipriya
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia
| | - Subash C. B. Gopinath
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis, 01000 Kangar, Perlis, Malaysia
- School of Bioprocess Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia
| | - Na Yang
- Department of Obstetrics, Dezhou People's Hospital, No. 1166 Dongfanghong West Road, Dezhou, Shandong Province, 253014, China
| |
Collapse
|
36
|
In Situ Oxidation of Cu 2O Crystal for Electrochemical Detection of Glucose. SENSORS 2019; 19:s19132926. [PMID: 31269709 PMCID: PMC6651079 DOI: 10.3390/s19132926] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/12/2019] [Revised: 06/13/2019] [Accepted: 06/20/2019] [Indexed: 02/01/2023]
Abstract
The development of a sensitive, quick-responding, and robust glucose sensor is consistently pursued for use in numerous applications. Here, we propose a new method for preparing a Cu2O electrode for the electrochemical detection of glucose concentration. The Cu2O glucose electrode was prepared by in situ electrical oxidation in an alkaline solution, in which Cu2O nanoparticles were deposited on the electrode surface to form a thin film, followed by the growth of Cu(OH)2 nanorods or nanotubes. The morphology and electrocatalytic activity of a Cu2O glucose electrode can be tuned by the current density, reaction time, and NaOH concentration. The results from XRD, SEM, and a Raman spectrum show that the electrode surface was coated with cubic Cu2O nanoparticles with diameters ranging from 50 to 150 nm. The electrode exhibited a detection limit of 0.0275 mM, a peak sensitivity of 2524.9 μA·cm−2·mM−1, and a linear response range from 0.1 to 1 mM. The presence of high concentrations of ascorbic acid, uric acid, dopamine and lactose appeared to have no effects on the detection of glucose, indicating a high specificity and robustness of this electrode.
Collapse
|
37
|
Dakshayini B, Reddy KR, Mishra A, Shetti NP, Malode SJ, Basu S, Naveen S, Raghu AV. Role of conducting polymer and metal oxide-based hybrids for applications in ampereometric sensors and biosensors. Microchem J 2019. [DOI: 10.1016/j.microc.2019.02.061] [Citation(s) in RCA: 134] [Impact Index Per Article: 22.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
38
|
3D porous structured polyaniline/reduced graphene oxide/copper oxide decorated electrode for high performance nonenzymatic glucose detection. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.04.032] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
39
|
Gao Y, Yu Q, Du Y, Yang M, Gao L, Rao S, Yang Z, Lan Q, Yang Z. Synthesis of Co3O4-NiO nano-needles for amperometric sensing of glucose. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.02.049] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
40
|
Jagadeesan M, Movlaee K, Krishnakumar T, Leonardi S, Neri G. One-step microwave-assisted synthesis and characterization of novel CuO nanodisks for non-enzymatic glucose sensing. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.01.024] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
41
|
Uniform and dense copper nanoparticles directly modified indium tin oxide electrode for non-enzymatic glucose sensing. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.01.045] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
42
|
Synthesis of the crystalline porous copper oxide architectures derived from metal-organic framework for electrocatalytic oxidation and sensitive detection of glucose. J IND ENG CHEM 2019. [DOI: 10.1016/j.jiec.2018.10.033] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
43
|
Mishra AK, Mukherjee B, Kumar A, Jarwal DK, Ratan S, Kumar C, Jit S. Superficial fabrication of gold nanoparticles modified CuO nanowires electrode for non-enzymatic glucose detection. RSC Adv 2019; 9:1772-1781. [PMID: 35516144 PMCID: PMC9059820 DOI: 10.1039/c8ra07516f] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2018] [Accepted: 12/23/2018] [Indexed: 11/28/2022] Open
Abstract
This paper describes a low-cost facile method to construct gold (Au) nanoparticles (NPs) modified copper oxide (CuO) nanowires (NWs) electrode on copper foil for the detection of glucose. Copper foil has been converted to aligned CuO NWs arrays by sequential formation of Cu(OH)2 followed by heat treatment induced phase transformation to CuO. Au NPs are deposited on CuO NWs via simple reductive solution chemistry to impart high surface to volume ratio and enhanced catalytic activity of the resulting electrode. Structure, microstructure and morphology of Cu, Cu(OH)2 NWs, CuO NWs, and Au NPs modified CuO NWs are investigated by X-ray diffraction (XRD) and scanning electron microscopy (SEM). The homogeneous distribution of Au NPs (average diameter ∼12 nm) on CuO NWs (average diameter 100 nm and aspect ratio ∼20) is confirmed by high-resolution transmission electron microscopy (HRTEM), scanning transmission electron microscopy (STEM) and elemental mapping. This CuO based glucose detection method gives the highest sensitivity along with the maximum linearity range. This non-enzymatic glucose sensor based on Au modified CuO NWs electrode gives broad linearity range from 0.5 μM to 5.9 mM. The sensor exhibits sensitivity of 4398.8 μA mM-1 cm-2, lower detection limit of 0.5 μM, and very fast response time of ∼5 s. Properties of the proposed glucose sensor are also investigated in human blood and it is found that the sensor is highly accurate and reliable. In addition, higher sensitivity and lower detection limit confirm that this device is suitable for invasive detection in saliva and urine.
Collapse
Affiliation(s)
- Ashwini Kumar Mishra
- Department of Electronics Engineering, Indian Institute of Technology (BHU) Varanasi-221005 India
| | - Bratindranath Mukherjee
- Department of Metallurgical Engineering, Indian Institute of Technology (BHU) Varanasi-221005 India
| | - Amit Kumar
- Department of Electronics Engineering, Indian Institute of Technology (BHU) Varanasi-221005 India
| | - Deepak Kumar Jarwal
- Department of Electronics Engineering, Indian Institute of Technology (BHU) Varanasi-221005 India
| | - Smrity Ratan
- Department of Electronics Engineering, Indian Institute of Technology (BHU) Varanasi-221005 India
| | - Chandan Kumar
- Department of Electronics Engineering, Indian Institute of Technology (BHU) Varanasi-221005 India
| | - Satyabrata Jit
- Department of Electronics Engineering, Indian Institute of Technology (BHU) Varanasi-221005 India
| |
Collapse
|
44
|
Yang D, Afroosheh S, Lee JO, Cho H, Kumar S, Siddique RH, Narasimhan V, Yoon YZ, Zayak AT, Choo H. Glucose Sensing Using Surface-Enhanced Raman-Mode Constraining. Anal Chem 2018; 90:14269-14278. [PMID: 30369240 DOI: 10.1021/acs.analchem.8b03420] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Diabetes mellitus is a chronic disease, and its management focuses on monitoring and lowering a patient's glucose level to prevent further complications. By tracking the glucose-induced shift in the surface-enhanced Raman-scattering (SERS) emission of mercaptophenylboronic acid (MPBA), we have demonstrated fast and continuous glucose sensing in the physiologically relevant range from 0.1 to 30 mM and verified the underlying mechanism using numerical simulations. Bonding of glucose to MPBA suppresses the "breathing" mode of MPBA at 1071 cm-1 and energizes the constrained-bending mode at 1084 cm-1, causing the dominant peak to shift from 1071 to 1084 cm-1. MPBA-glucose bonding is also reversible, allowing continuous tracking of ambient glucose concentrations, and the MPBA-coated substrates showed very stable performance over a 30 day period, making the approach promising for long-term continuous glucose monitoring. Using Raman-mode-constrained, miniaturized SERS implants, we also successfully demonstrated intraocular glucose measurements in six ex vivo rabbit eyes within ±0.5 mM of readings obtained using a commercial glucose sensor.
Collapse
Affiliation(s)
- Daejong Yang
- Department of Medical Engineering , California Institute of Technology , Pasadena , California 91125 , United States.,Department of Mechanical & Automotive Engineering , Kongju National University , Cheonan 31080 , Republic of Korea
| | - Sajjad Afroosheh
- Department of Physics & Astronomy, Center for Photochemical Sciences , Bowling Green State University , Bowling Green , Ohio 43403 , United States
| | - Jeong Oen Lee
- Department of Electrical Engineering , California Institute of Technology , Pasadena , California 91125 , United States
| | - Hyunjun Cho
- Department of Electrical Engineering , California Institute of Technology , Pasadena , California 91125 , United States
| | - Shailabh Kumar
- Department of Medical Engineering , California Institute of Technology , Pasadena , California 91125 , United States
| | - Radwanul H Siddique
- Department of Medical Engineering , California Institute of Technology , Pasadena , California 91125 , United States
| | - Vinayak Narasimhan
- Department of Medical Engineering , California Institute of Technology , Pasadena , California 91125 , United States
| | - Young-Zoon Yoon
- Device Lab, Device & System Research Center , Samsung Advanced Institute of Technology (SAIT) , Suwon 16678 , Republic of Korea
| | - Alexey T Zayak
- Department of Physics & Astronomy, Center for Photochemical Sciences , Bowling Green State University , Bowling Green , Ohio 43403 , United States
| | - Hyuck Choo
- Department of Medical Engineering , California Institute of Technology , Pasadena , California 91125 , United States.,Department of Electrical Engineering , California Institute of Technology , Pasadena , California 91125 , United States.,Device Lab, Device & System Research Center , Samsung Advanced Institute of Technology (SAIT) , Suwon 16678 , Republic of Korea
| |
Collapse
|
45
|
Biosynthesis of Copper Oxide (CuO) Nanowires and Their Use for the Electrochemical Sensing of Dopamine. NANOMATERIALS 2018; 8:nano8100823. [PMID: 30322069 PMCID: PMC6215139 DOI: 10.3390/nano8100823] [Citation(s) in RCA: 78] [Impact Index Per Article: 11.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/17/2018] [Revised: 10/04/2018] [Accepted: 10/09/2018] [Indexed: 11/17/2022]
Abstract
A facile one-step, eco-friendly, and cost-effective approach for the formation of copper oxide (CuO) nanowires by a green method using saponin-rich Sapindus mukorossi fruit extract (SMFE). The physio-chemical characteristics of the synthesized CuO nanowires have been characterized by X-ray Diffractometry (XRD), X-ray Photoelectron Spectroscopy (XPS), FT-IR (Fourier Transform Infrared Spectroscopy, FE-SEM (Scanning Electron Microscopy), and High-Resolution Transmission Electron Microscopy (HR-TEM). Further, the electrocatalytic activity of the CuO nanowires synthesized with SMFE has been investigated, and they have been used as dopamine (DA) sensors. Because of their unique properties, the CuO nanowires/GCE exhibited remarkable electrochemical response for the detection of DA with enhanced current response. The anodic current demonstrated that the CuO nanowires/GCE linearly detects the concentration of DA over the range of 0.1 µM to 0.105 mM of DA with a regression co-efficient of 0.9960. The obtained results illustrated that the synthesized CuO nanowires can easily stimulate the electron transfer reaction between DA and the nanowires modified electrode with the improvement of the conductivity and stability of the electrode. This remarkable electrocatalytic property of CuO nanowires makes it a unique electrochemical sensor for the detection of DA. Furthermore, the sensor is free from the interference of ascorbic acid, uric acid, and other interfering species. Moreover, the anti-interference performance also showed that the CuO nanowires/GCE could be employed for the determination of DA in real samples with good selectivity and sensitivity.
Collapse
|
46
|
A novel impedimetric glucose biosensor based on immobilized glucose oxidase on a CuO-Chitosan nanobiocomposite modified FTO electrode. Int J Biol Macromol 2018; 118:649-660. [DOI: 10.1016/j.ijbiomac.2018.05.228] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2018] [Revised: 05/30/2018] [Accepted: 05/30/2018] [Indexed: 12/11/2022]
|
47
|
Cheng X, Zhao H, Huang W, Chen J, Wang S, Dong J, Deng Y. Rational Design of Yolk-Shell CuO/Silicalite-1@mSiO 2 Composites for a High-Performance Nonenzymatic Glucose Biosensor. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2018; 34:7663-7672. [PMID: 29871483 DOI: 10.1021/acs.langmuir.8b01051] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
In this study, an interface coassembly strategy is employed to rationally synthesize a yolk-shell CuO/silicalite-1@void@mSiO2 composite consisting of silicalite-1 supported CuO nanoparticles confined in the hollow space of mesoporous silica, and the obtained composite materials were used as a novel nonenzymatic biosensor for highly sensitive and selective detecting glucose with excellent anti-interference ability. The synthesis of CuO/silicalite-1@mSiO2 includes four steps: coating silicalite-1 particles with resorcinol-formaldehyde polymer (RF), immobilization of copper species, interface deposition of a mesoporous silica layer, and final calcination in air to decompose RF and form CuO nanoparticles. The unique hierarchical porous structure with mesopores and micropores is beneficial to selectively enrich glucose for fast oxidation into gluconic acid. Besides, the mesopores in the silica shell can effectively inhibit the large interfering substances or biomacromolecules diffusing into the void as well as the loss of CuO nanoparticles. The hollow chamber inside serves as a nanoreactor for glucose oxidation catalyzed by the active CuO nanoparticles, which are spatially accessible for glucose molecules. The nonenzymatic glucose biosensors based on CuO/silicalite-1@mSiO2 materials show excellent electrocatalytic sensing performance with a wide linear range (5-500 μM), high sensitivity (5.5 μA·mM-1·cm-2), low detection limit (0.17 μM), and high selectivity against interfering species. Furthermore, the unique sensors even display a good capability in the determination of glucose in real blood serum samples.
Collapse
Affiliation(s)
- Xiaowei Cheng
- Department of Chemistry, State Key Laboratory of Molecular Engineering of Polymers, Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials, iChEM (Collaborative Innovation Center of Chemistry for Energy Materials) , Fudan University , Shanghai 200433 , China
| | - Haochen Zhao
- College of Science , University of Shanghai for Science and Technology , Shanghai 200093 , China
| | - Wenfeng Huang
- School of Environmental and Chemical Engineering , Shanghai University , Shanghai 200444 , China
| | - Jinyang Chen
- School of Environmental and Chemical Engineering , Shanghai University , Shanghai 200444 , China
| | - Shixia Wang
- College of Science , University of Shanghai for Science and Technology , Shanghai 200093 , China
| | - Junping Dong
- Department of Chemistry, College of Science , Shanghai University , Shanghai 200444 , China
| | - Yonghui Deng
- Department of Chemistry, State Key Laboratory of Molecular Engineering of Polymers, Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials, iChEM (Collaborative Innovation Center of Chemistry for Energy Materials) , Fudan University , Shanghai 200433 , China
- State Key Lab of Transducer Technology, Shanghai Institute of Microsystem and Information Technology , Chinese Academy of Sciences , Shanghai 200050 , China
| |
Collapse
|
48
|
Zang G, Hao W, Li X, Huang S, Gan J, Luo Z, Zhang Y. Copper nanowires-MOFs-graphene oxide hybrid nanocomposite targeting glucose electro-oxidation in neutral medium. Electrochim Acta 2018. [DOI: 10.1016/j.electacta.2018.05.016] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
49
|
Zhu X, Ju Y, Chen J, Liu D, Liu H. Nonenzymatic Wearable Sensor for Electrochemical Analysis of Perspiration Glucose. ACS Sens 2018; 3:1135-1141. [PMID: 29767510 DOI: 10.1021/acssensors.8b00168] [Citation(s) in RCA: 69] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
We report a nonenzymatic wearable sensor for electrochemical analysis of perspiration glucose. Multipotential steps are applied on a Au electrode, including a high negative pretreatment potential step for proton reduction which produces a localized alkaline condition, a moderate potential step for electrocatalytic oxidation of glucose under the alkaline condition, and a positive potential step to clean and reactivate the electrode surface for the next detection. Fluorocarbon-based materials were coated on the Au electrode for improving the selectivity and robustness of the sensor. A fully integrated wristband is developed for continuous real-time monitoring of perspiration glucose during physical activities, and uploading the test result to a smartphone app via Bluetooth.
Collapse
Affiliation(s)
- Xiaofei Zhu
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Yinhui Ju
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Jian Chen
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Deye Liu
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| | - Hong Liu
- State Key Laboratory of Bioelectronics, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China
| |
Collapse
|
50
|
Nguyen TT, Huy BT, Hwang SY, Vuong NM, Pham QT, Nghia NN, Kirtland A, Lee YI. Preparing cuprous oxide nanomaterials by electrochemical method for non-enzymatic glucose biosensor. NANOTECHNOLOGY 2018; 29:205501. [PMID: 29480163 DOI: 10.1088/1361-6528/aab229] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Cuprous oxide (Cu2O) nanostructure has been synthesized using an electrochemical method with a two-electrode system. Cu foils were used as electrodes and NH2(OH) was utilized as the reducing agent. The effects of pH and applied voltages on the morphology of the product were investigated. The morphology and optical properties of Cu2O particles were characterized using scanning electron microscopy, x-ray diffraction, and diffuse reflectance spectra. The synthesized Cu2O nanostructures that formed in the vicinity of the anode at 2 V and pH = 11 showed high uniform distribution, small size, and good electrochemical sensing. These Cu2O nanoparticles were coated on an Indium tin oxide substrate and applied to detect non-enzyme glucose as excellent biosensors. The non-enzyme glucose biosensors exhibited good performance with high response, good selectivity, wide linear detection range, and a low detection limit at 0.4 μM. Synthesized Cu2O nanostructures are potential materials for a non-enzyme glucose biosensor.
Collapse
Affiliation(s)
- Thu-Thuy Nguyen
- Department of Chemistry, Changwon National University, Changwon 51140, Republic of Korea
| | | | | | | | | | | | | | | |
Collapse
|