1
|
Guo Y, Zhang X, Zhang H, Liu Y, Shi J, Meng H, Chen X, Lan Q, Zhu B. Application of microfluidic technologies in forensic analysis. Electrophoresis 2023; 44:1725-1743. [PMID: 37857551 DOI: 10.1002/elps.202200268] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 08/17/2023] [Accepted: 08/28/2023] [Indexed: 10/21/2023]
Abstract
The application of microfluidic technology in forensic medicine has steadily expanded over the last two decades due to the favorable features of low cost, rapidity, high throughput, user-friendliness, contamination-free, and minimum sample and reagent consumption. In this context, bibliometric methods were adopted to visualize the literature information contained in the Science Citation Index Expanded from 1989 to 2022, focusing on the co-occurrence analysis of forensic and microfluidic topics. A deep interpretation of the literature was conducted based on co-occurrence results, in which microfluidic technologies and their applications in forensic medicine, particularly forensic genetics, were elaborated. The purpose of this review is to provide an impartial evaluation of the utilization of microfluidic technology in forensic medicine. Additionally, the challenges and future trends of implementing microfluidic technology in forensic genetics are also addressed.
Collapse
Affiliation(s)
- Yuxin Guo
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
- Clinical Research Center of Shaanxi Province for Dental and Maxillofacial Diseases, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
| | - Xingru Zhang
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
- Clinical Research Center of Shaanxi Province for Dental and Maxillofacial Diseases, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
- Guangzhou Key Laboratory of Forensic Multi-Omics for Precision Identification, School of Forensic Medicine, Southern Medical University, Guangzhou, Guangdong, P. R. China
- College of Forensic Medicine, Xi'an Jiaotong University Health Science Center, Xi'an, Shaanxi, P. R. China
| | - Haoqing Zhang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
| | - Yaoshun Liu
- Ankang Hospital of Traditional Chinese Medicine, Ankang, Shaanxi, P. R. China
| | - Jianfeng Shi
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
- Clinical Research Center of Shaanxi Province for Dental and Maxillofacial Diseases, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
| | - Haotian Meng
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
- Clinical Research Center of Shaanxi Province for Dental and Maxillofacial Diseases, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
| | - Xin Chen
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
- Clinical Research Center of Shaanxi Province for Dental and Maxillofacial Diseases, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
| | - Qiong Lan
- Guangzhou Key Laboratory of Forensic Multi-Omics for Precision Identification, School of Forensic Medicine, Southern Medical University, Guangzhou, Guangdong, P. R. China
- Microbiome Medicine Center, Department of Laboratory Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, P. R. China
| | - Bofeng Zhu
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi'an Jiaotong University, Xi'an, Shaanxi, P. R. China
- Guangzhou Key Laboratory of Forensic Multi-Omics for Precision Identification, School of Forensic Medicine, Southern Medical University, Guangzhou, Guangdong, P. R. China
- Microbiome Medicine Center, Department of Laboratory Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, Guangdong, P. R. China
| |
Collapse
|
2
|
Bruijns B, Knotter J, Tiggelaar R. A Systematic Review on Commercially Available Integrated Systems for Forensic DNA Analysis. SENSORS (BASEL, SWITZERLAND) 2023; 23:1075. [PMID: 36772114 PMCID: PMC9919030 DOI: 10.3390/s23031075] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 01/11/2023] [Accepted: 01/12/2023] [Indexed: 06/18/2023]
Abstract
This systematic review describes and discusses three commercially available integrated systems for forensic DNA analysis, i.e., ParaDNA, RapidHIT, and ANDE. A variety of aspects, such as performance, time-to-result, ease-of-use, portability, and costs (per analysis run) of these three (modified) rapid DNA analysis systems, are considered. Despite their advantages and developmental progress, major steps still have to be made before rapid systems can be broadly applied at crime scenes for full DNA profiling. Aspects in particular that need (further) improvement are portability, performance, the possibility to analyze a (wider) variety of (complex) forensic samples, and (cartridge) costs. Moreover, steps forward regarding ease-of-use and time-to-result will benefit the broader use of commercial rapid DNA systems. In fact, it would be a profit if rapid DNA systems could be used for full DNA profile generation as well as indicative analyses that can give direction to forensic investigators which will speed up investigations.
Collapse
Affiliation(s)
- Brigitte Bruijns
- Technologies for Criminal Investigations, Saxion University of Applied Sciences, M.H. Tromplaan 28, 7513 AB Enschede, The Netherlands
- Politieacademie, Arnhemseweg 348, 7334 AC Apeldoorn, The Netherlands
| | - Jaap Knotter
- Technologies for Criminal Investigations, Saxion University of Applied Sciences, M.H. Tromplaan 28, 7513 AB Enschede, The Netherlands
- Politieacademie, Arnhemseweg 348, 7334 AC Apeldoorn, The Netherlands
| | - Roald Tiggelaar
- NanoLab Cleanroom, MESA+ Institute, University of Twente, Drienerlolaan 5, 7500 AE Enschede, The Netherlands
| |
Collapse
|
3
|
Rapid DNA from a Disaster Victim Identification Perspective: is it a game changer? Forensic Sci Int Genet 2022; 58:102684. [DOI: 10.1016/j.fsigen.2022.102684] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2021] [Revised: 02/03/2022] [Accepted: 03/03/2022] [Indexed: 11/18/2022]
|
4
|
Yang J, Hurth C, Nordquist A, Smith S, Zenhausern F. Integrated Microfluidic System for Rapid DNA Fingerprint Analysis: A Miniaturized Integrated DNA Analysis System (MiDAS)-Swab Sample-In to DNA Profile-Out. Methods Mol Biol 2019; 1906:207-224. [PMID: 30488395 DOI: 10.1007/978-1-4939-8964-5_14] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
A fully automated rapid DNA analysis system requires integrating several operational elements performing multiple steps onto one single microfluidic platform. The functions to include on the microfluidic platform consist of substrate lysis, lysate DNA extraction, single or multiplexed PCR amplification, amplicon separation, and product readout. Here we describe a fully automated integrated system for forensic short tandem repeat (STR) analysis of reference samples, achieving buccal swab-in and DNA profile-out.
Collapse
Affiliation(s)
- Jianing Yang
- Center for Applied NanoBioscience and Medicine, University of Arizona College of Medicine-Phoenix, Phoenix, AZ, USA.
| | - Cedric Hurth
- Center for Applied NanoBioscience and Medicine, University of Arizona College of Medicine-Phoenix, Phoenix, AZ, USA
| | - Alan Nordquist
- Center for Applied NanoBioscience and Medicine, University of Arizona College of Medicine-Phoenix, Phoenix, AZ, USA
| | - Stan Smith
- Center for Applied NanoBioscience and Medicine, University of Arizona College of Medicine-Phoenix, Phoenix, AZ, USA
| | - Frederic Zenhausern
- Center for Applied NanoBioscience and Medicine, University of Arizona College of Medicine-Phoenix, Phoenix, AZ, USA
| |
Collapse
|
5
|
Han J, Gan W, Zhuang B, Sun J, Zhao L, Ye J, Liu Y, Li CX, Liu P. A fully integrated microchip system for automated forensic short tandem repeat analysis. Analyst 2018; 142:2004-2012. [PMID: 28513665 DOI: 10.1039/c7an00295e] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We have successfully developed an integrated microsystem that combines two plastic microchips for DNA extraction and PCR amplification with a glass capillary array electrophoresis chip together in a compact control and detection instrument for automated forensic short tandem repeat (STR) analysis. DNA extraction followed by an "in situ PCR" was conducted in a single reaction chamber of the microchip based on a filter paper-based extraction methodology. PCR products were then mixed with sizing standards by an injection electrode and injected into the electrophoresis chip for four-color confocal fluorescence detection. The entire STR analysis can be completed in about two hours without any human intervention. Since the 15-plex STR system has a more stringent requirement for PCR efficiency, we optimized the structure of the plastic DNA extraction and amplification chip, in which the reaction chamber was formed by sandwiching a hollow structure layer with two blank cover layers, to reduce the adsorption of PCR reagents to the surfaces. In addition, PCR additives, bovine serum albumin, poly(ethylene glycol), and more magnesium chloride were included into the on-chip multiplex STR system. The limit-of-detection study demonstrated that our microsystem was able to produce full 15-plex STR profiles from 3.75 ng standard K562 DNA. Buccal swab and whole blood samples were also successfully typed by our system, validating the feasibility of performing rapid DNA typing in a "sample-in-answer-out" manner for on-site forensic human identification.
Collapse
Affiliation(s)
- Junping Han
- Department of Biomedical Engineering, School of Medicine, Collaborative Innovation Center for Diagnosis and Treatment of Infectious Diseases, Tsinghua University, Beijing, 100084, China.
| | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Han JP, Sun J, Wang L, Liu P, Zhuang B, Zhao L, Liu Y, Li CX. The Optimization of Electrophoresis on a Glass Microfluidic Chip and its Application in Forensic Science. J Forensic Sci 2017; 62:1603-1612. [PMID: 28168694 DOI: 10.1111/1556-4029.13408] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2016] [Revised: 10/23/2016] [Accepted: 11/29/2016] [Indexed: 11/29/2022]
Abstract
Microfluidic chips offer significant speed, cost, and sensitivity advantages, but numerous parameters must be optimized to provide microchip electrophoresis detection. Experiments were conducted to study the factors, including sieving matrices (the concentration and type), surface modification, analysis temperature, and electric field strengths, which all impact the effectiveness of microchip electrophoresis detection of DNA samples. Our results showed that the best resolution for ssDNA was observed using 4.5% w/v (7 M urea) lab-fabricated LPA gel, dynamic wall coating of the microchannel, electrophoresis temperatures between 55 and 60°C, and electrical fields between 350 and 450 V/cm on the microchip-based capillary electrophoresis (μCE) system. One base-pair resolution could be achieved in the 19-cm-length microchannel. Furthermore, both 9947A standard genomic DNA and DNA extracted from blood spots were demonstrated to be successfully separated with well-resolved DNA peaks in 8 min. Therefore, the microchip electrophoresis system demonstrated good potential for rapid forensic DNA analysis.
Collapse
Affiliation(s)
- Jun P Han
- Key Laboratory of Forensic Genetics, Beijing Engineering Research Center of Crime Scene Evidence Examination, Institute of Forensic Science, Ministry of Public Security, Beijing, 100038, China.,Forensic Science and Technology Department of Chaoyang Sub-bureau, Beijing Public Security Bureau, Beijing, 100102, China
| | - Jing Sun
- Key Laboratory of Forensic Genetics, Beijing Engineering Research Center of Crime Scene Evidence Examination, Institute of Forensic Science, Ministry of Public Security, Beijing, 100038, China
| | - Le Wang
- Key Laboratory of Forensic Genetics, Beijing Engineering Research Center of Crime Scene Evidence Examination, Institute of Forensic Science, Ministry of Public Security, Beijing, 100038, China
| | - Peng Liu
- Tsinghua University, Beijing, 100084, China
| | - Bin Zhuang
- Tsinghua University, Beijing, 100084, China
| | - Lei Zhao
- Key Laboratory of Forensic Genetics, Beijing Engineering Research Center of Crime Scene Evidence Examination, Institute of Forensic Science, Ministry of Public Security, Beijing, 100038, China
| | - Yao Liu
- Key Laboratory of Forensic Genetics, Beijing Engineering Research Center of Crime Scene Evidence Examination, Institute of Forensic Science, Ministry of Public Security, Beijing, 100038, China
| | - Cai X Li
- Key Laboratory of Forensic Genetics, Beijing Engineering Research Center of Crime Scene Evidence Examination, Institute of Forensic Science, Ministry of Public Security, Beijing, 100038, China
| |
Collapse
|
7
|
Yang M, Yin C, Lv Y, Yang Y, Chen J, Yu Z, Liu X, Xu M, Chen F, Wu H, Yan J. Development of a rapid 21-plex autosomal STR typing system for forensic applications. Electrophoresis 2016; 37:2789-2799. [PMID: 27066765 DOI: 10.1002/elps.201500498] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2015] [Revised: 03/03/2016] [Accepted: 03/24/2016] [Indexed: 11/11/2022]
Abstract
DNA-STR genotyping technology has been widely used in forensic investigations. Even with such success, there is a great need to reduce the analysis time. In this study, we established a new rapid 21-plex STR typing system, including 13 CODIS loci, Penta D, Penta E, D12S391, D2S1338, D6S1043, D19S433, D2S441 and Amelogenin loci. This system could shorten the amplification time to a minimum of 90 min and does not require DNA extraction from the samples. Validation of the typing system complied with the Scientific Working Group on DNA Analysis Methods (SWGDAM) and the Chinese National Standard (GA/T815-2009) guidelines. The results demonstrated that this 21-plex STR typing system was a valuable tool for rapid criminal investigation.
Collapse
Affiliation(s)
- Meng Yang
- CAS Key Laboratory of Genome Sciences and Information, Beijing Institute of Genomics, Chinese Academy of Sciences, Beijing, P. R. China
| | - Caiyong Yin
- Department of Forensic Medicine, Nanjing Medical University, Nanjing, Jiangsu, P. R. China
| | - Yuexin Lv
- Beijing Microread Genetics Co., Ltd, Beijing, P. R. China
| | - Yaran Yang
- CAS Key Laboratory of Genome Sciences and Information, Beijing Institute of Genomics, Chinese Academy of Sciences, Beijing, P. R. China
| | - Jing Chen
- CAS Key Laboratory of Genome Sciences and Information, Beijing Institute of Genomics, Chinese Academy of Sciences, Beijing, P. R. China
| | - Zailiang Yu
- Beijing Microread Genetics Co., Ltd, Beijing, P. R. China
| | - Xu Liu
- Beijing Center for Physical and Chemical Analysis, Beijing, P. R. China.,Beijing Engineering Technology Research Centre of Gene Sequencing and Gene Function Analysis, Beijing, P. R. China
| | - Meibo Xu
- Beijing Microread Genetics Co., Ltd, Beijing, P. R. China
| | - Feng Chen
- Department of Forensic Medicine, Nanjing Medical University, Nanjing, Jiangsu, P. R. China
| | - Huijuan Wu
- Beijing Center for Physical and Chemical Analysis, Beijing, P. R. China. .,Beijing Engineering Technology Research Centre of Gene Sequencing and Gene Function Analysis, Beijing, P. R. China.
| | - Jiangwei Yan
- CAS Key Laboratory of Genome Sciences and Information, Beijing Institute of Genomics, Chinese Academy of Sciences, Beijing, P. R. China.
| |
Collapse
|
8
|
Total integrated slidable and valveless solid phase extraction-polymerase chain reaction-capillary electrophoresis microdevice for mini Y chromosome short tandem repeat genotyping. Biosens Bioelectron 2016; 78:489-496. [DOI: 10.1016/j.bios.2015.11.079] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2015] [Revised: 11/17/2015] [Accepted: 11/26/2015] [Indexed: 11/21/2022]
|
9
|
A Genome-Wide Scan of DNA Methylation Markers for Distinguishing Monozygotic Twins. Twin Res Hum Genet 2015; 18:670-9. [PMID: 26500037 DOI: 10.1017/thg.2015.73] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Identification of individuals within pairs of monozygotic (MZ) twins remains unresolved using common forensic DNA typing technology. For some criminal cases involving MZ twins as suspects, the twins had to be released due to inability to identify which of the pair was the perpetrator. In this study, we performed a genome-wide scan on whole blood-derived DNA from four pairs of healthy phenotypically concordant MZ twins using the methylated DNA immunoprecipitation sequencing technology to identify candidate DNA methylation markers with capacity to distinguish MZ twins within a pair. We identified 38 differential methylation regions showing within-pair methylation differences in all four MZ pairs. These are all located in CpG islands, 17 of which are promoter-associated, 17 are intergenic islands, and four are intragenic islands. Genes associated with these markers are related with cell proliferation, differentiation, and growth and development, including zinc finger proteins, PRRX2, RBBP9, or are involved in G-protein signaling, such as the regulator of G-protein signaling 16. Further validation studies on additional MZ twins are now required to evaluate the broader utility of these 38 markers for forensic use.
Collapse
|
10
|
Romsos EL, Vallone PM. Rapid PCR of STR markers: Applications to human identification. Forensic Sci Int Genet 2015; 18:90-9. [DOI: 10.1016/j.fsigen.2015.04.008] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2015] [Revised: 04/03/2015] [Accepted: 04/21/2015] [Indexed: 10/23/2022]
|
11
|
A miniature quantitative PCR device for directly monitoring a sample processing on a microfluidic rapid DNA system. Biomed Microdevices 2015; 16:905-14. [PMID: 25106501 DOI: 10.1007/s10544-014-9895-8] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
We report a microfluidic device and measurement method to perform real-time PCR (or qPCR) in a miniaturized configuration for on-chip implementation using reaction volumes of less than 20 μL. The qPCR bioreactor is designed as a module to be embedded in an automated sample-in/profile-out system for rapid DNA biometrics or human identification. The PCR mixture is excited with a 505 nm diode-pumped solid-state laser (DPSSL) and the fluorescence build-up is measured using optical fibers directly embedded to the sidewalls of the microfluidic qPCR bioreactor. We discuss manufacturing and operating parameters necessary to adjust the internal surface conditions and temperature profiles of the bioreactor and to optimize the yield and quality of the PCR reaction for the amplification of 62 bp hTERT intron fragments using the commercial Quantifiler® kit (Life Technologies, Carlsbad, CA) commonly accepted for genotyping analysis. We designed a microfluidic device suitable for continuously processing a specimen by efficiently mixing the reagents from the kit to a set volume of DNA template on chip. Our approach relies on a calibration curve for the specific device using control DNA. We successfully applied this method to determine the concentration of genomic DNA extracted from a buccal swab on separate microfluidic devices which are operated upstream the qPCR device and perform buccal swab lysis and buccal DNA extraction. A precise correlation between the amount determined on chip and that obtained using a commercial cycler is demonstrated.
Collapse
|
12
|
Bartsch MS, Edwards HS, Lee D, Moseley CE, Tew KE, Renzi RF, Van de Vreugde JL, Kim H, Knight DL, Sinha A, Branda SS, Patel KD. The rotary zone thermal cycler: a low-power system enabling automated rapid PCR. PLoS One 2015; 10:e0118182. [PMID: 25826708 PMCID: PMC4380418 DOI: 10.1371/journal.pone.0118182] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2014] [Accepted: 01/09/2015] [Indexed: 12/17/2022] Open
Abstract
Advances in molecular biology, microfluidics, and laboratory automation continue to expand the accessibility and applicability of these methods beyond the confines of conventional, centralized laboratory facilities and into point of use roles in clinical, military, forensic, and field-deployed applications. As a result, there is a growing need to adapt the unit operations of molecular biology (e.g., aliquoting, centrifuging, mixing, and thermal cycling) to compact, portable, low-power, and automation-ready formats. Here we present one such adaptation, the rotary zone thermal cycler (RZTC), a novel wheel-based device capable of cycling up to four different fixed-temperature blocks into contact with a stationary 4-microliter capillary-bound sample to realize 1-3 second transitions with steady state heater power of less than 10 W. We demonstrate the utility of the RZTC for DNA amplification as part of a highly integrated rotary zone PCR (rzPCR) system that uses low-volume valves and syringe-based fluid handling to automate sample loading and unloading, thermal cycling, and between-run cleaning functionalities in a compact, modular form factor. In addition to characterizing the performance of the RZTC and the efficacy of different online cleaning protocols, we present preliminary results for rapid single-plex PCR, multiplex short tandem repeat (STR) amplification, and second strand cDNA synthesis.
Collapse
Affiliation(s)
- Michael S. Bartsch
- Sandia National Laboratories, Livermore, CA, United States of America
- * E-mail:
| | | | - Daniel Lee
- Sandia National Laboratories, Livermore, CA, United States of America
| | | | - Karen E. Tew
- Sandia National Laboratories, Livermore, CA, United States of America
| | - Ronald F. Renzi
- Sandia National Laboratories, Livermore, CA, United States of America
| | | | - Hanyoup Kim
- Sandia National Laboratories, Livermore, CA, United States of America
| | | | - Anupama Sinha
- Sandia National Laboratories, Livermore, CA, United States of America
| | - Steven S. Branda
- Sandia National Laboratories, Livermore, CA, United States of America
| | - Kamlesh D. Patel
- Sandia National Laboratories, Livermore, CA, United States of America
| |
Collapse
|
13
|
An evaluation of the RapidHIT® system for reliably genotyping reference samples. Forensic Sci Int Genet 2014; 13:104-11. [DOI: 10.1016/j.fsigen.2014.06.012] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2014] [Revised: 04/23/2014] [Accepted: 06/16/2014] [Indexed: 11/21/2022]
|
14
|
Yang J, Brooks C, Estes MD, Hurth CM, Zenhausern F. An integratable microfluidic cartridge for forensic swab samples lysis. Forensic Sci Int Genet 2013; 8:147-58. [PMID: 24315603 DOI: 10.1016/j.fsigen.2013.08.012] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2012] [Revised: 08/13/2013] [Accepted: 08/28/2013] [Indexed: 11/19/2022]
Abstract
Fully automated rapid forensic DNA analysis requires integrating several multistep processes onto a single microfluidic platform, including substrate lysis, extraction of DNA from the released lysate solution, multiplexed PCR amplification of STR loci, separation of PCR products by capillary electrophoresis, and analysis for allelic peak calling. Over the past several years, most of the rapid DNA analysis systems developed started with the reference swab sample lysate and involved an off-chip lysis of collected substrates. As a result of advancement in technology and chemistry, addition of a microfluidic module for swab sample lysis has been achieved in a few of the rapid DNA analysis systems. However, recent reports on integrated rapid DNA analysis systems with swab-in and answer-out capability lack any quantitative and qualitative characterization of the swab-in sample lysis module, which is important for downstream forensic sample processing. Maximal collection and subsequent recovery of the biological material from the crime scene is one of the first and critical steps in forensic DNA technology. Herein we present the design, fabrication and characterization of an integratable swab lysis cartridge module and the test results obtained from different types of commonly used forensic swab samples, including buccal, saliva, and blood swab samples, demonstrating the compatibility with different downstream DNA extraction chemistries. This swab lysis cartridge module is easy to operate, compatible with both forensic and microfluidic requirements, and ready to be integrated with our existing automated rapid forensic DNA analysis system. Following the characterization of the swab lysis module, an integrated run from buccal swab sample-in to the microchip CE electropherogram-out was demonstrated on the integrated prototype instrument. Therefore, in this study, we demonstrate that this swab lysis cartridge module is: (1) functionally, comparable with routine benchtop lysis, (2) compatible with various types of swab samples and chemistries, and (3) integratable to achieve a micro total analysis system (μTAS) for rapid DNA analysis.
Collapse
Affiliation(s)
- Jianing Yang
- Center for Applied NanoBioscience and Medicine, The University of Arizona College of Medicine, 425 N. 5th Street, Phoenix, AZ 85004 USA.
| | | | | | | | | |
Collapse
|
15
|
Estes MD, Hurth C, Barrett M, Zenhausern F. A tuneable array of unique steady-state microfluidic gradients. Phys Chem Chem Phys 2013; 15:12805-14. [DOI: 10.1039/c3cp44640a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
16
|
Hurth C, Gu J, Aboud M, Estes MD, Nordquist AR, McCord B, Zenhausern F. Direct loading of polymer matrices in plastic microchips for rapid DNA analysis: a comparative study. Electrophoresis 2012; 33:2604-11. [PMID: 22899270 DOI: 10.1002/elps.201200148] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
We report the design and performance validation of microfluidic separation technologies for human identification using a disposable plastic device suitable for integration into an automated rapid DNA analysis system. A fabrication process for a 15-cm long hot-embossed plastic microfluidic devices with a smooth semielliptical cross section out of cyclic olefin copolymer is presented. We propose a mixed polymer solution of 95% w/v hydroxyethylcellulose and 5% w/v polyvinylpyrrolidone for a final polymer concentration of 2.5 or 3.0% to be used as coating and sieving matrix for DNA separation. This formulation allows preparing the microchip without pretreatment in a single-loading step and provides high-resolution separation (≈1.2 bp for fragments <200 bp), which is superior to existing commercial matrices under the same conditions. The hot-embossed device performance is characterized and compared to injection-molded devices made out of cyclic olefin copolymer based on their respective injector geometry, channel shape, and surface charges. Each device design is assessed by fluorescence videomicroscopy to evaluate the formation of injection plugs, then by comparing electropherograms for the separation of a DNA size standard relevant to human identification.
Collapse
Affiliation(s)
- Cedric Hurth
- Center for Applied Nanobioscience and Medicine, The University of Arizona College of Medicine, Phoenix, AZ 85004, USA.
| | | | | | | | | | | | | |
Collapse
|
17
|
Olasagasti F, Ruiz de Gordoa JC. Miniaturized technology for protein and nucleic acid point-of-care testing. Transl Res 2012; 160:332-45. [PMID: 22683416 PMCID: PMC7104926 DOI: 10.1016/j.trsl.2012.02.012] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/29/2011] [Revised: 02/22/2012] [Accepted: 02/24/2012] [Indexed: 01/26/2023]
Abstract
The field of point-of-care (POC) testing technology is developing quickly and producing instruments that are increasingly reliable, while their size is being gradually reduced. Proteins are a common target for POC analyses and the detection of protein markers typically involves immunoassays aimed at detecting different groups of proteins such as tumor markers, inflammation proteins, and cardiac markers; but other techniques can also be used to analyze plasma proteins. In the case of nucleic acids, hybridization and amplification strategies can be used to record electromagnetic or electric signals. These techniques allow for the identification of specific viral or bacterial infections as well as specific cancers. In this review, we consider some of the latest advances in the analysis of specific nucleic acid and protein biomarkers, taking into account their trend toward miniaturization and paying special attention to the technology that can be implemented in future applications, such as lab-on-a-chip instruments.
Collapse
Key Words
- poc, point-of-care
- lfi, lateral flow immunochromatography
- psa, prostate-specific antigen
- hcg, human chorionic gonadotropin
- tsh, thyroid-stimulating hormone
- seb, staphylococcal enterotixin b
- fret, förster resonance energy transfer
- mmp, matrix metalloproteinase 9
- bnp, b-type natriuretic peptide
- crp, c-reactive protein
- pdms, polydimethylsiloxane
- ig, immunoglobulin
- hb a1c, hemoglobin a1c
- ag, antigen
- ab, antibody
- tnfα, tumor necrosis factor α
- pct, procalcitonin
- il, interleukin
- pcr, polymerase chain reaction
- ca, cancer antigen
- cea, carcinoembryonic antigen
- nmp, nuclear matrix protein
- s100β, s100 calcium binding protein beta
- elisa, enzyme-linked immunosorbent assay
- vegf, vascular endothelial growth factor
- pmma, methyl methacrylate
- ctni, cardiac troponin i
- egf, epidermal growth factor
- ip, interferon-inducible
- mcp, monocyte chemoattractant protein
- timp-1, tissue inhibitor of matrix metalloproteinase-1
- rantes, regulated upon activation, normal t cell expressed and secreted
- mip-1 β, macrophage inflammatory protein-beta
- ctnt, cardiac troponin t
- hrp, horseradish peroxidase
- si-fet, silicon field-effect-transistor
- afp, alpha fetoprotein
- act, antichymotrypsin
- mia, magnetic immunoassay
- apc, allophycocyanin
- he4, human epididymis protein 4
- tmb, 3,3',5,5'-tetramethylbenzidine
- hp, hairpin
- lamp, loop-mediated isothermal amplification
- mrsa, methicillin resistant staphylococcus aureus
- fmdv, foot-and-mouth disease virus
- mμlamp, multiplex microfluidic lamp
- had, helicase-dependent amplification
- nasba, nucleic acid sequence based amplification
- lfm, lateral flow chromatography microarrays
- hsp, heat shock proteins
- spr, surface plasmon resonance
- mems, micro-electro-mechanical systems
- mimed, magnetic integrated microfluidic electrochemical detectors
Collapse
Affiliation(s)
- Felix Olasagasti
- Department of Biochemistry and Molecular Biology, Farmazia Fakultatea/Facultad de Farmacia, UPV-EHU, Gasteiz, Spain.
| | | |
Collapse
|
18
|
Estes MD, Yang J, Duane B, Smith S, Brooks C, Nordquist A, Zenhausern F. Optimization of multiplexed PCR on an integrated microfluidic forensic platform for rapid DNA analysis. Analyst 2012; 137:5510-9. [DOI: 10.1039/c2an35768b] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|