1
|
Piuzzi NS, Klika AK, Lu Q, Higuera-Rueda CA, Stappenbeck T, Visperas A. Periprosthetic joint infection and immunity: Current understanding of host-microbe interplay. J Orthop Res 2024; 42:7-20. [PMID: 37874328 DOI: 10.1002/jor.25723] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 09/19/2023] [Accepted: 10/17/2023] [Indexed: 10/25/2023]
Abstract
Periprosthetic joint infection (PJI) is a major complication of total joint arthroplasty. Even with current treatments, failure rates are unacceptably high with a 5-year mortality rate of 26%. Majority of the literature in the field has focused on development of better biomarkers for diagnostics and treatment strategies including innovate antibiotic delivery systems, antibiofilm agents, and bacteriophages. Nevertheless, the role of the immune system, our first line of defense during PJI, is not well understood. Evidence of infection in PJI patients is found within circulation, synovial fluid, and tissue and include numerous cytokines, metabolites, antimicrobial peptides, and soluble receptors that are part of the PJI diagnosis workup. Macrophages, neutrophils, and myeloid-derived suppressor cells (MDSCs) are initially recruited into the joint by chemokines and cytokines produced by immune cells and bacteria and are activated by pathogen-associated molecular patterns. While these cells are efficient killers of planktonic bacteria by phagocytosis, opsonization, degranulation, and recruitment of adaptive immune cells, biofilm-associated bacteria are troublesome. Biofilm is not only a physical barrier for the immune system but also elicits effector functions. Additionally, bacteria have developed mechanisms to evade the immune system by inactivating effector molecules, promoting killing or anti-inflammatory effector cell phenotypes, and intracellular persistence and dissemination. Understanding these shortcomings and the mechanisms by which bacteria can subvert the immune system may open new approaches to better prepare our own immune system to combat PJI. Furthermore, preoperative immune system assessment and screening for dysregulation may aid in developing preventative interventions to decrease PJI incidence.
Collapse
Affiliation(s)
- Nicolas S Piuzzi
- Department of Orthopaedic Surgery, Cleveland Clinic Adult Reconstruction Research (CCARR), Cleveland Clinic, Cleveland, Ohio, USA
- Department of Biomedical Engineering, Cleveland Clinic, Cleveland, Ohio, USA
| | - Alison K Klika
- Department of Orthopaedic Surgery, Cleveland Clinic Adult Reconstruction Research (CCARR), Cleveland Clinic, Cleveland, Ohio, USA
| | - Qiuhe Lu
- Department of Inflammation and Immunity, Cleveland Clinic, Cleveland, Ohio, USA
| | | | | | - Anabelle Visperas
- Department of Orthopaedic Surgery, Cleveland Clinic Adult Reconstruction Research (CCARR), Cleveland Clinic, Cleveland, Ohio, USA
| |
Collapse
|
2
|
Ganesan N, Ronsmans S, Hoet P. Differential immunological effects of silica nanoparticles on peripheral blood mononuclear cells of silicosis patients and controls. Front Immunol 2022; 13:1025028. [PMID: 36311760 PMCID: PMC9606771 DOI: 10.3389/fimmu.2022.1025028] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Accepted: 09/21/2022] [Indexed: 11/29/2022] Open
Abstract
Silicosis is a fibrotic disease caused by the inhalation of respirable silica particles, which are typically engulfed by alveolar macrophages and subsequently induce the release of inflammatory cytokines. Various animal experimental and human studies have focused on modeling silicosis, to assess the interactions of macrophages and other cell types with silica particles. There is still, however, limited knowledge on the differential response upon silica-exposure between silicosis patients and controls. We focused on studying the responsiveness of peripheral blood mononuclear cells (PBMCs) to silica nanoparticles (SiNPs) - Ludox and NM-200 - of silicosis patients and controls. The proliferative capacity of T- CD3+ and B- CD19+ cells, were evaluated via Carboxyfluorescein succinimidyl ester (CFSE) assay. The activation status of lymphocyte subsets and response to silica were also evaluated by comparing the extent of micro-granuloma or aggregate formation with the cytokine secretion profiles between both groups of individuals. The proliferative capacity of CD19+ cells was elevated in silicotic patients as opposed to controls. Subsets of regulatory T cells (CD4+ CD25+ and CD8+ CD25+) and immunoglobulins IgM and IgG were also significantly increased in patients. The number and the size of aggregates formed were higher with SiNPs stimulation in patients compared to controls. Multivariable analysis also elucidated the role of key cytokines like interleukin-1β (IL-1β), IL-6 and interferon-gamma (IFN-γ), which were upregulated in SiNP-stimulated PBMCs of patients compared to controls. Our ex vivo model thus has potential to provide insights into the immunological effects of silica particles in lymphocytes of silicosis patients and controls.
Collapse
Affiliation(s)
- Nirosha Ganesan
- Laboratory of Toxicology, Unit of Environment & Health, Department of Public Health and Primary Care, KU Leuven, Leuven, Belgium
- Laboratory of Respiratory Diseases and Thoracic Surgery (BREATHE), KU Leuven, Leuven, Belgium
| | - Steven Ronsmans
- Laboratory of Toxicology, Unit of Environment & Health, Department of Public Health and Primary Care, KU Leuven, Leuven, Belgium
- Clinic for Occupational and Environmental Medicine, Department of Respiratory Diseases, University Hospitals Leuven, Leuven, Belgium
| | - Peter Hoet
- Laboratory of Toxicology, Unit of Environment & Health, Department of Public Health and Primary Care, KU Leuven, Leuven, Belgium
- Laboratory of Respiratory Diseases and Thoracic Surgery (BREATHE), KU Leuven, Leuven, Belgium
- *Correspondence: Peter Hoet,
| |
Collapse
|
3
|
Samelko L, Caicedo M, McAllister K, Jacobs J, Hallab NJ. Metal-induced delayed type hypersensitivity responses potentiate particle induced osteolysis in a sex and age dependent manner. PLoS One 2021; 16:e0251885. [PMID: 34003868 PMCID: PMC8130946 DOI: 10.1371/journal.pone.0251885] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Accepted: 05/04/2021] [Indexed: 12/20/2022] Open
Abstract
It is widely recognized that innate macrophage immune reactions to implant debris are central to the inflammatory responses that drive biologic implant failure over the long term. Less common, adaptive lymphocyte immune reactions to implant debris, such as delayed type hypersensitivity (DTH), can also affect implant performance. It is unknown which key patient factors, if any, mediate these adaptive immune responses that potentiate particle/macrophage mediated osteolysis. The objective of this investigation was to determine to what degree known adaptive immune responses to metal implant debris can affect particle-induced osteolysis (PIO); and if this pathomechanism is dependent on: 1) innate immune danger signaling, i.e., NLRP3 inflammasome activity, 2) sex, and/or 3) age. We used an established murine calvaria model of PIO using male and female wild-type C57BL/6 vs. Caspase-1 deficient mice as well as young (12–16 weeks old) vs. aged (18–24 months old) female and male C57BL/6 mice. After induction of metal-DTH, and Cobalt-alloy particle (ASTM F-75, 0.4um median diameter) calvaria challenge, bone resorption was assessed using quantitative micro-computed tomography (micro-CT) analysis and immune responses were assessed by measuring paw inflammation, lymphocyte transformation test (LTT) reactivity and adaptive immune cytokines IFN-gamma and IL-17 (ELISA). Younger aged C57BL/6 female mice exhibited the highest rate and severity of metal sensitivity lymphocyte responses that also translated into higher PIO compared to any other experimental group. The absence of inflammasome/caspase-1 activity significantly suppressed DTH metal-reactivity and osteolysis in both male and female Caspase-1 deficient mice. These murine model results indicate that young female mice are more predisposed to metal-DTH augmented inflammatory responses to wear debris, which is highly influenced by active NLRP3 inflammasome/caspase-1 danger signaling. If these results are clinically meaningful for orthopedic patients, then younger female individuals should be appropriately assessed and followed for DTH derived peri-implant complications.
Collapse
Affiliation(s)
- Lauryn Samelko
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, United States of America
| | - Marco Caicedo
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, United States of America
| | - Kyron McAllister
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, United States of America
| | - Joshua Jacobs
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, United States of America
| | - Nadim James Hallab
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, United States of America
- * E-mail:
| |
Collapse
|
4
|
A Clinical Case Report of a Potential Acute Allergic Reaction with Titanium Dental Implant. Case Rep Dent 2021; 2021:5592934. [PMID: 33953988 PMCID: PMC8057912 DOI: 10.1155/2021/5592934] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 03/20/2021] [Accepted: 03/30/2021] [Indexed: 11/18/2022] Open
Abstract
Titanium hypersensitivity is rare, but it may exist among patients who need dental implant treatment. It could contribute to mild or severe peri-implant tissue hypersensitivity reactions and affect patients' oral and general health according to some clinical reports. In extreme cases, it may lead to implant failure or extraction. In this case report, a 64-year-old Caucasian female patient received a titanium implant placement on #5. Right after the implant placement, she reported the symptoms of pain, eczema, and slight extraoral swelling, along with significant burning sensation occurring intra- and extraorally. The symptoms were not released after the systemic intervention of antibiotics for six days. On retrieving her medical history, the patient reported a previous allergic reaction to jewelry-like earrings in her childhood. The diagnosis of titanium hypersensitivity was made based on the rapid onset of symptoms and her metal allergy history. Therefore, the dental implant was removed after diagnosis, and a bone allograft was used to preserve the alveolar bone volume. Immediately after implant extraction, the swelling and burning sensation were receded. A complete recovery was achieved three weeks later. The dimension of the alveolar ridge bone was found well maintained in 10 weeks follow-up visit. Conclusion. Rapid onset of peri-implant gingival swelling may indicate a hypersensitivity to titanium implant in the clinic. For patients with a history of allergy to jewelry, the hypersensitivity tests to titanium alloy such as patch test or lymphocyte transformation test should be recommended as part of the dental implant treatment plan.
Collapse
|
5
|
Wu K, Li B, Guo JJ. Fatigue Crack Growth and Fracture of Internal Fixation Materials in In Vivo Environments-A Review. MATERIALS (BASEL, SWITZERLAND) 2021; 14:E176. [PMID: 33401437 PMCID: PMC7795221 DOI: 10.3390/ma14010176] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/16/2020] [Revised: 12/22/2020] [Accepted: 12/28/2020] [Indexed: 11/17/2022]
Abstract
The development of crack patterns is a serious problem affecting the durability of orthopedic implants and the prognosis of patients. This issue has gained considerable attention in the medical community in recent years. This literature focuses on the five primary aspects relevant to the evaluation of the surface cracking patterns, i.e., inappropriate use, design flaws, inconsistent elastic modulus, allergic reaction, poor compatibility, and anti-corrosiveness. The hope is that increased understanding will open doors to optimize fabrication for biomedical applications. The latest technological issues and potential capabilities of implants that combine absorbable materials and shape memory alloys are also discussed. This article will act as a roadmap to be employed in the realm of orthopedic. Fatigue crack growth and the challenges associated with materials must be recognized to help make new implant technologies viable for wider clinical adoption. This review presents a summary of recent findings on the fatigue mechanisms and fracture of implant in the initial period after surgery. We propose solutions to common problems. The recognition of essential complications and technical problems related to various approaches and material choices while satisfying clinical requirements is crucial. Additional investigation will be needed to surmount these challenges and reduce the likelihood of fatigue crack growth after implantation.
Collapse
Affiliation(s)
- Kailun Wu
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, Suzhou 215000, China; (K.W.); (B.L.)
- Department of Orthopedics, Suzhou Dushuhu Public Hospital (Dushuhu Public Hospital Affiliated to Soochow University), Suzhou 215000, China
| | - Bin Li
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, Suzhou 215000, China; (K.W.); (B.L.)
- Orthopedic Research Unit, Soochow University, Suzhou 215006, China
| | - Jiong Jiong Guo
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, Suzhou 215000, China; (K.W.); (B.L.)
| |
Collapse
|
6
|
Avila JD, Isik M, Bandyopadhyay A. Titanium-Silicon on CoCr Alloy for Load-Bearing Implants Using Directed Energy Deposition-Based Additive Manufacturing. ACS APPLIED MATERIALS & INTERFACES 2020; 12:51263-51272. [PMID: 33167622 DOI: 10.1021/acsami.0c15279] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Cobalt-chromium (CoCr) alloys offer outstanding wear resistance when compared to other biocompatible metallic materials and are extensively used in articulating surfaces of total hip and knee arthroplasty. However, CoCr alloys' biocompatibility is known to be inferior to titanium (Ti). Wear- and corrosion-induced metal-ion release from CoCr alloys has been reported to cause cancer and negative physiological impacts. In this study, CoCr alloy was coated with commercially pure Ti (CpTi) and CpTi-Silicon (CoCrTi-Si) with the specific objective of reducing Co and Cr ion release during articulation, without degrading the excellent wear resistance of the CoCr alloy. Directed energy deposition (DED), a blown powder-based laser additive manufacturing technique, was utilized to process CpTi- and CpTi-Si-based coatings on Stellite 6B commercial CoCr alloy. Scanning electron microscopy (SEM), X-ray diffraction (XRD) analyses, and hardness testing found that refined carbides and titanium silicides increased the hardness from 321 ± 13 to 758 ± 48 HV0.5. Tribological studies determined a comparable wear rate between Stellite 6B alloy and CoCrTi-Si in DI water but a statistically significant reduction in Dulbecco's Modified Eagle Medium (DMEM). The wear rates for Stellite 6B were 8.5 ± 0.8 × 10-5 and 12.9 ± 0.4 × 10-5 mm3/Nm in DI water and DMEM, respectively. While the wear rates for CoCrTi-Si were 9.1 ± 0.5 × 10-5 and 8.9 ± 0.8 × 10-5 mm3/Nm in DI water and DMEM, respectively. Contact resistance acquisition displayed the presence of a passive film formation during tribological testing. ICP-MS results for Stellite 6B and CoCrTi-Si concluded a reduction of Co ions release in DI water from 149.8 ± 66.7 to 17.5 ± 0.7 ppb and a reduction in Cr ions release from 66.7 ± 32.4 to 18.0 ± 0.5 ppb, respectively. In DMEM media, Co ion release for Stellite 6B and CoCrTi-Si reduced from 10.1 ± 1.4 to 4.1 ± 0.2 ppb and Cr ion release for Stellite 6B and CoCrTi-Si reduced from 8.7 ± 0.2 to 5.0 ± 0.7 ppb, respectively. The current study revealed a new mode of manufacturing for CoCr alloy-based load-bearing implants that can reduce toxic metal ions release due to wear- and corrosion-induced damages.
Collapse
Affiliation(s)
- Jose D Avila
- W. M. Keck Biomedical Materials Research Lab, School of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States
| | - Murat Isik
- W. M. Keck Biomedical Materials Research Lab, School of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States
| | - Amit Bandyopadhyay
- W. M. Keck Biomedical Materials Research Lab, School of Mechanical and Materials Engineering, Washington State University, Pullman, Washington 99164, United States
| |
Collapse
|
7
|
Transition from metal-DTH resistance to susceptibility is facilitated by NLRP3 inflammasome signaling induced Th17 reactivity: Implications for orthopedic implants. PLoS One 2019; 14:e0210336. [PMID: 30653583 PMCID: PMC6336398 DOI: 10.1371/journal.pone.0210336] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Accepted: 12/20/2018] [Indexed: 12/13/2022] Open
Abstract
Metal hypersensitivity has been recognized as an adverse biologic reaction that can compromise total joint arthroplasty (TJA) performance. However, the etiology of metal hypersensitivity responses in TJAs remains unclear. Metal implant debris is known to act as a danger signal that drives NLRP3 inflammasome activation. It remains unknown if implant debris induced inflammasome activation regulates T cell lineage in TJA metal hypersensitivity responses. In this study, we show both in vivo and in vitro that the pathogenesis of metal hypersensitivity responses to implant debris are largely dependent on activation of the inflammasome/caspase-1 pathway and subsequent production of IL-17A/F by CD4+ T cells. Inhibiting either the inflammasome pathway or IL-17A bioactivity in vivo and in vitro (in vivo using NLRP3 and Caspase-1 deficient mice or in vitro using blocking agents such as Capase-1 inhibitor, IL-1Ra and anti-IL-17A), significantly (p<0.05) mitigated metal-DTH paw inflammation as well as lymphocyte cytokine (IFN-γ and IL-17) and proliferation responses in metal-sensitized mice and primary human PBMCs. This study provides mechanistic insight into how in vivo exposure to orthopedic implant debris, and metals in general, elicits NLRP3 inflammasome activation that mediates the generation of IL-17A/F producing CD4+ T cells, leading to metal-delayed type hypersensitivity reactions.
Collapse
|
8
|
Kilb BKJ, Kurmis AP, Parry M, Sherwood K, Keown P, Masri BA, Duncan CP, Garbuz DS. Frank Stinchfield Award: Identification of the At-risk Genotype for Development of Pseudotumors Around Metal-on-metal THAs. Clin Orthop Relat Res 2018; 476. [PMID: 29529651 PMCID: PMC6259707 DOI: 10.1007/s11999.0000000000000028] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Once touted as the future of hip arthroplasty, metal-on-metal (MoM) bearing surfaces have fallen sharply from favor with the emergence of a strong body of evidence demonstrating unacceptably high premature implant failure rates. The previously unpredictable development of adverse local tissue reactions (ALTRs) has been a substantive contributor to this. Although the underlying pathophysiology of these so-called "pseudotumors" is now well understood, the fundamental predisposing patient risk factors have remained elusive. QUESTIONS/PURPOSES The aim of this research, as a clinical-genotype correlation analysis, was to identify specific alleles (genes) associated with the development of ALTRs in patients with in situ MoM THAs. METHODS A case-control study of patients who received a large-head, primary MoM THA between 2005 and 2008 was performed with a minimum followup of 5 years. Twenty-six patients who had undergone revision of a primary MoM THA secondary to symptomatic ALTRs were recruited. The mean timeframe from primary MoM THA to symptomatic revision was 5.5 years (range, 1-10 years). Twenty-eight control subjects were randomly selected asymptomatic patients with no evidence of ALTRs on protocol-specific screening. Baseline demographics and high-resolution genotype (human leukocyte antigen [HLA] Class II) were collected for all patients. Cohorts were similar with respect to age at the time of primary MoM THA (mean, 54.8 versus 54.9 years, p = 0.95) and serum cobalt (mean, 5.5 versus 8.5 μg/L, p = 0.09) and chromium concentrations (mean, 2.9 versus 4.2 μg/L, p = 0.27). The association between genotype and revision surgery secondary to ALTRs was determined with gender as a covariate. RESULTS The prevalence of the risk genotype was 30% (16 of 54) among the entire cohort. Adjusting for sex, the odds of revision were 6.1 times greater among patients with the risk genotype present than among patients without (95% confidence interval [CI], 1.5-25.4; p = 0.01). Among females, the specificity of the risk genotype was 1.0 (95% CIexact, 0.5-1.0; pexact = 0.03), and for males, it was 0.8 (95% CIexact, 0.6-0.9; pexact < 0.01). CONCLUSIONS The findings of this study suggest that, among patients with a primary MoM THA, allelic variation within the HLA Class II loci may be a strong, independent risk factor associated with the need for subsequent revision surgery secondary to pseudotumor formation. CLINICAL RELEVANCE Given the hypothesis-generating nature of this novel undertaking, confirmatory prospective clinical studies are required to further elucidate this correlation and to explore the clinical utility of targeted genetic screening in this specific population. This research may, however, represent a key missing piece in the puzzle that is metal ion-induced pseudotumor formation.
Collapse
Affiliation(s)
- Brett K J Kilb
- B. K. J. Kilb, A. P. Kurmis, M. Parry, B. A. Masri, C. P. Duncan, D. S., Garbuz Department of Orthopaedics, University of British Columbia, Vancouver, British Columbia, Canada K. Sherwood, P. Keown Department of Pathology (&) Laboratory Medicine, University of British Columbia, Vancouver, British Columbia, Canada P. Keown, Department of Medicine, University of British Columbia, Vancouver, British Columbia, Canada A. P. Kurmis, Discipline of Medical Specialties, University of Adelaide, Adelaide, SA, Australia
| | | | | | | | | | | | | | | |
Collapse
|
9
|
Effects of wear particles of polyether-ether-ketone and cobalt-chromium-molybdenum on CD4- and CD8-T-cell responses. Oncotarget 2017. [PMID: 29541407 PMCID: PMC5834256 DOI: 10.18632/oncotarget.23757] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
T-cells, second only to macrophages, are often considered as the potential cells involved in debris-related failure of arthroplasty. Here, we assessed the effects of particulate wear debris on T-cells and inflammatory reactions. Blood samples from 25 donors were incubated with polyether-ether-ketone (PEEK) and cobalt-chromium-molybdenum (CoCrMo) particles generated by custom cryo-milling and pulverization. The T-cell phenotypes were assessed using immunostaining and flow cytometry. For the in vivo study, 0.1 mL of each particle suspension (approximately 1.0 × 108 wear particles) was injected into murine knee joints; the synovium and spleen were collected one week after the operation for histological examination and immunofluorescence staining. The T-cell responses observed included low-level activation of Th1, Th2, Th17, and CD8+ pathways after 72 h of co-culture of the particles with peripheral blood mononuclear cells. Obvious CD8+ T-cell responses were observed in local synovium and peripheral spleen, with higher inflammatory cytokine expression in the CoCrMo group. Relatively minor cytotoxic and immunological reactions were observed in vitro, with PEEK and CoCrMo particle-induced immune responses being primarily mediated by CD8+ T-cells, rather than CD4+ T-cells, in vivo. Overall, PEEK wear particles induced fewer inflammatory reactions than CoCrMo particles. This study verified that PEEK was suitable as a potential alternative for metals in total knee replacements in terms of the immunological reaction to PEEK particles, and shed light on the effects of wear particles from polymer and metal-based implants on immune responses.
Collapse
|
10
|
Innocenti M, Vieri B, Melani T, Paoli T, Carulli C. Metal hypersensitivity after knee arthroplasty: fact or fiction? ACTA BIO-MEDICA : ATENEI PARMENSIS 2017. [PMID: 28657568 PMCID: PMC6178998 DOI: 10.23750/abm.v88i2-s.6517] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Background and aim of the work: Hypersensitivity to metals in the general population has an incidence of about 15%, and in rising also for the higher number of joint replacements in the last decades. Total Knee Arthroplasty (TKA) represents the most performed orthopaedic procedure during last years, and it seems to be particularly associated with sensitization after surgery. On the other hand, there is a rising amount of patients with painful but well implanted and functioning TKAs: in certain cases, after the exclusion of the most frequent causes of failure, a condition of hypersensitivity may be found, and a revision with anallergic implants is mandatory. The present study is a review of the potential problems related to hypersensitivity in TKA, its possible diagnostic procedures, and the surgical options to date available. Methods: Medical history, patch testing, and other specific laboratory assays are useful to assess a status of metals hypersensitivity before surgery in subjects undergoing a knee replacement, or even after TKA in patients complaining pain in otherwise well implanted and aligned prostheses. However, few groups worlwide deal with such condition, and all proposed diagnostic protocols may be considered still today conjectural. On the other hand, these represent the most updated knowledge of this condition, and may be useful for both the patient and the orthopaedic surgeon. Once assessed a possible or ascertained allergy to metals, several options are available for primary andr revision knee surgery, in order to avoid the risk of hypersensitivity. Results: A review of the recent publications on this topic and an overview of the related aspects has been made to understand a condition to date considered negligible. Conclusions: Hypersensitivity to metals has not to be nowadays considered a “fiction”, but rather a possible preoperative risk or a postoperative cause of failure of TKA. Crucial is the information of patients and the medical history, associated in suspect cases to laboratory testings. Today in the market several knee implants are available and safe for allergic patients undergoing TKA. (www.actabiomedica.it)
Collapse
|
11
|
Innocenti M, Vieri B, Melani T, Paoli T, Carulli C. Metal hypersensitivity after knee arthroplasty: fact or fiction? ACTA BIO-MEDICA : ATENEI PARMENSIS 2017; 88:78-83. [PMID: 28657568 DOI: 10.23750/abm.v88i2 -s.6517] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 06/01/2017] [Accepted: 06/01/2017] [Indexed: 01/23/2023]
Abstract
BACKGROUND AND AIM OF THE WORK Hypersensitivity to metals in the general population has an incidence of about 15%, and in rising also for the higher number of joint replacements in the last decades. Total Knee Arthroplasty (TKA) represents the most performed orthopaedic procedure during last years, and it seems to be particularly associated with sensitization after surgery. On the other hand, there is a rising amount of patients with painful but well implanted and functioning TKAs: in certain cases, after the exclusion of the most frequent causes of failure, a condition of hypersensitivity may be found, and a revision with anallergic implants is mandatory. The present study is a review of the potential problems related to hypersensitivity in TKA, its possible diagnostic procedures, and the surgical options to date available. METHODS Medical history, patch testing, and other specific laboratory assays are useful to assess a status of metals hypersensitivity before surgery in subjects undergoing a knee replacement, or even after TKA in patients complaining pain in otherwise well implanted and aligned prostheses. However, few groups worlwide deal with such condition, and all proposed diagnostic protocols may be considered still today conjectural. On the other hand, these represent the most updated knowledge of this condition, and may be useful for both the patient and the orthopaedic surgeon. Once assessed a possible or ascertained allergy to metals, several options are available for primary andr revision knee surgery, in order to avoid the risk of hypersensitivity. RESULTS A review of the recent publications on this topic and an overview of the related aspects has been made to understand a condition to date considered negligible. CONCLUSIONS Hypersensitivity to metals has not to be nowadays considered a "fiction", but rather a possible preoperative risk or a postoperative cause of failure of TKA. Crucial is the information of patients and the medical history, associated in suspect cases to laboratory testings. Today in the market several knee implants are available and safe for allergic patients undergoing TKA.
Collapse
|
12
|
Abstract
BACKGROUND Precision medicine has been adopted in a range of clinical settings where omics data have led to greater characterisation of disease and stratification of patients into subcategories of phenotypes and pathologies. However, in orthopaedics, precision medicine lags behind other disciplines such as cancer. Joint registries have now amassed a huge body of data pertaining to implant performance which can be broken down into performance statistics for different material types in different cohorts of patients. The National Joint Registry of England, Wales and Northern Ireland (NJR) is now one of the largest datasets available. Other registries such as those from Sweden and Australia however contain longer follow-up. Together, these registries can provide a wealth of informative for the orthopaedics community when considering which implant to give to any particular patient. QUESTIONS/PURPOSES We aim to explore the benefits of combining multiple large data streams including joint registries, published data on osteoarthritis (OA) pathogenesis and pathology and data concerning performance of each implant material combination in terms of biocompatibility. We believe that this analysis will provide a comprehensive overview of implant performance hopefully aiding surgeons in making more informed choices about which implant should be used in which patient. METHODS Data from three joint registries were combined with established literature to highlight the heterogeneity of OA disease and the different clinical outcomes following arthroplasty with a range of material types. RESULTS This review confirms that joint registries are unable to consider differences in arthritis presentation or underlying drivers of pathology. OA is now recognised to present with varying pathology with differing morbidity in different patient populations. Equally, just as OA is a heterogeneous disease, there are disparate responses to wear debris from different material combinations used in joint replacement surgery. This has been highlighted by recent high-profile scrutiny of early failure of metal-on-metal total hip replacement (THR) implants. CONCLUSIONS Bringing together data from joint registries, biomarker analysis, phenotyping of OA patients and knowledge of how different patients respond to implant debris will lead to a truly personalised approach to treating OA patients, ensuring that the correct implant is given to the correct patient at the correct time.
Collapse
|
13
|
Carossino AM, Carulli C, Ciuffi S, Carossino R, Zappoli Thyrion GD, Zonefrati R, Innocenti M, Brandi ML. Hypersensitivity reactions to metal implants: laboratory options. BMC Musculoskelet Disord 2016; 17:486. [PMID: 27881114 PMCID: PMC5120482 DOI: 10.1186/s12891-016-1342-y] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/27/2016] [Accepted: 11/14/2016] [Indexed: 11/30/2022] Open
Abstract
Background All implant compounds undergo an electrochemical process when in contact with biological fluids, as well as mechanical corrosion due to abrasive wear, with production of metal debris that may inhibit repair processes. None of the commonly-used methods can diagnose implant allergies when used singly, therefore a panel of tests should be performed on allergic patients as pre-operative screening, or when a postoperative metal sensitisation is suspected. Methods We analysed patients with painful prostheses and subjects prone to allergies using the Patch Test in comparison with the Lymphocyte Transformation Test. Cytokine production was evaluated to identify prognostic markers for early diagnosis of aseptic loosening. Metal debris endocytosis and cytoskeletal rearrangement was visualised by confocal microscopy. Results Our results demonstrate that the Lymphocyte Transformation Test can identify patients who have a predisposition to develop allergic reactions and can confirm the diagnosis of hypersensitivity in patients with painful prostheses. The prevalence of a Th2-cytokine pattern may be used to identify predisposition to the development of allergic diseases, while the selective presence of osteoclastogenic cytokines may be used as predictor of a negative outcome in patients with painful prosthesis. The hypothesis of the prognostic value of these cytokines as early markers of aseptic loosening is attractive, but its confirmation would require extensive testing. Conclusions The Lymphocyte Transformation Test is the most suitable method for testing systemic allergies. We suggest that the combined use of the Patch Test and the Lymphocyte Transformation Test, associated with cytokine detection in selected patients, could provide a useful tool for preventive evaluation of immune reactivity in patients undergoing primary joint replacement surgery, and for clinical monitoring of the possible onset of a metal sensitization in patients with implanted devices.
Collapse
Affiliation(s)
- Anna Maria Carossino
- Department of Surgery and Translational Medicine, University of Florence, Viale Pieraccini 6, 50139, Florence, Italy
| | - Christian Carulli
- Department of Surgery and Translational Medicine, University of Florence, Viale Pieraccini 6, 50139, Florence, Italy
| | - Simone Ciuffi
- Department of Surgery and Translational Medicine, University of Florence, Viale Pieraccini 6, 50139, Florence, Italy
| | - Roberto Carossino
- Department of Surgery and Translational Medicine, University of Florence, Viale Pieraccini 6, 50139, Florence, Italy
| | | | - Roberto Zonefrati
- Department of Surgery and Translational Medicine, University of Florence, Viale Pieraccini 6, 50139, Florence, Italy
| | - Massimo Innocenti
- Department of Surgery and Translational Medicine, University of Florence, Viale Pieraccini 6, 50139, Florence, Italy
| | - Maria Luisa Brandi
- Department of Surgery and Translational Medicine, University of Florence, Viale Pieraccini 6, 50139, Florence, Italy.
| |
Collapse
|
14
|
Royhman D, Patel M, Runa MJ, Wimmer MA, Jacobs JJ, Hallab NJ, Mathew MT. Fretting-corrosion behavior in hip implant modular junctions: The influence of friction energy and pH variation. J Mech Behav Biomed Mater 2016; 62:570-587. [DOI: 10.1016/j.jmbbm.2016.05.024] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2015] [Revised: 02/24/2016] [Accepted: 05/18/2016] [Indexed: 11/30/2022]
|
15
|
Abstract
Osteolysis and aseptic loosening currently contribute 75 % of implant failures. Furthermore, with over four million joint replacements projected to be performed in the United States annually, osteolysis and aseptic loosening may continue to pose a significant morbidity. This paper reviews the osteolysis cascade leading to osteoclast activation and bone resorption at the biochemical level. Additionally, the metal ion release mechanism from metallic implants is elucidated. Even though metal ions are not the predominating initiator of osteolysis, they do increase the concentration of key inflammatory cytokines that stimulate osteoclasts and prove to be a contributor to osteolysis and aseptic loosening. Osteolysis is a competitive mechanism among a number of biological reactions, which includes debris release, macrophage and osteoclast activation, an inflammatory response as well as metal ion release. Pharmacological therapy for component loosening has also been reviewed. A non-surgical treatment of osteolysis has not been found in the literature and thus may become an area of future research. Even though this research is warranted, comprehensively understanding the immune response to orthopedic implants and their metallic ions, and thus, creating improved prostheses appears to be the most cost-effective approach to decrease the morbidity related to osteolysis and to design implants with greater longevity. The ionic forms, cytokines, toxicity, gene expression, biological effects, and hypersensitivity responses of metallic elements from metal implants are summarized as well.
Collapse
|
16
|
How has the introduction of new bearing surfaces altered the biological reactions to byproducts of wear and modularity? Clin Orthop Relat Res 2014; 472:3699-708. [PMID: 24942963 PMCID: PMC4397759 DOI: 10.1007/s11999-014-3725-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Biological responses to wear debris were largely elucidated in studies focused on conventional ultrahigh-molecular-weight polyethylene (UHMWPE) and some investigations of polymethymethacrylate cement and orthopaedic metals. However, newer bearing couples, in particular metal-on-metal but also ceramic-on-ceramic bearings, may induce different biological reactions. QUESTIONS/PURPOSES Does wear debris from the newer bearing surfaces result in different biological responses compared with the known responses observed with conventional metal-on-UHMWPE bearings? METHODS A Medline search of articles published after 1996 supplemented by a hand search of reference lists of included studies and relevant conference proceedings was conducted to identify the biological responses to orthopaedic wear debris with a focus on biological responses to wear generated from metal-on-highly crosslinked polyethylene, metal-on-metal, ceramic-on-ceramic, and ceramic-on-polyethylene bearings. Articles were selected using criteria designed to identify reports of wear debris particles and biological responses contributing to prosthesis failure. Case reports and articles focused on either clinical outcomes or tribology were excluded. A total of 83 papers met the criteria and were reviewed in detail. RESULTS Biological response to conventional UHMWPE is regulated by the innate immune response. It is clear that the physical properties of debris (size, shape, surface topography) influence biological responses in addition to the chemical composition of the biomaterials. Highly crosslinked UHMWPE particles have the potential to alter, rather than eliminate, the biological response to conventional UHMWPE. Metal wear debris can generate elevated plasma levels of cobalt and chromium ions. These entities can provoke responses that extend to the elicitation of an acquired immune response. Wear generated from ceramic devices is significantly reduced in volume and may provide the impression of an "inert" response, but clinically relevant biological reactions do occur, including granulomatous responses in periprosthetic tissues. CONCLUSIONS The material composition of the device, the physical form of the debris, and disease pathophysiology contribute to complex interactions that determine the outcome to all wear debris. Metal debris does appear to increase the complexity of the biological response with the addition of immunological responses (and possibly direct cellular cytotoxicity) to the inflammatory reaction provoked by wear debris in some patients. However, the introduction of highly crosslinked polyethylene and ceramic bearing surfaces shows promising signs of reducing key biological mechanisms in osteolysis.
Collapse
|
17
|
Total knee arthroplasty in patients with hypersensitivity to metals. INTERNATIONAL ORTHOPAEDICS 2014; 38:329-33. [PMID: 24389947 DOI: 10.1007/s00264-013-2229-2] [Citation(s) in RCA: 45] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2013] [Accepted: 11/25/2013] [Indexed: 10/25/2022]
Abstract
PURPOSE We evaluated the risk of hypersensitivity to metals in a population of consecutive subjects undergoing a total knee arthroplasty (TKA). We also proposed a diagnostic pathway to address any sensitivity to metals. We finally presented the mid-term outcomes of a full non allergenic knee implant. METHODS We developed a protocol based on the medical history, patch testing, and on specific laboratory assays, in order to assess a sensitization to metals. Twenty-four patients (25 knees) with referred or suspected allergy to metals were found in more than 1,000 treated patients, with a mean age of 72.9 years. We proceeded to a radiologic study, a clinical evaluation by the visual analogic scale (VAS), and Knee Society rating system (KSS). In all cases a full anallergic cemented implant with an oxidized zirconium femoral component and an all-polyethylene tibial baseplate was chosen. RESULTS Four (16.6%) of the 24 patients were considered to be hypersensitive to metals. The mean follow-up was 79.2 months. No patient reported any reaction related to hypersensitivity or complications after TKA. The VAS improved from a mean preoperative value of 7.2 to 1.8 postoperatively; the KSS and the functional score increased from 38 to 91 points and from 39 to 88 points, respectively. CONCLUSIONS We consider careful research of medical history for metals hypersensitivity crucial, and we perform patch testing and lab assays in case of doubtful sensitization. The choice of a modern hypoallergenic implant may prevent any kind of potential reactions.
Collapse
|
18
|
Prospective analysis of human leukocyte functional tests reveals metal sensitivity in patients with hip implant. J Orthop Surg Res 2013; 8:12. [PMID: 23680415 PMCID: PMC3674931 DOI: 10.1186/1749-799x-8-12] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2012] [Accepted: 04/28/2013] [Indexed: 12/16/2022] Open
Abstract
Background The aim of the study was to examine the reactivity of peripheral human leukocytes to various metal ions prior and following hip replacement in order to investigate implant-induced metal sensitivity. Methods Three patient groups were set up: (1) individuals without implants and no history of metal allergy (7 cases), (2) individuals without implants and known history of metal allergy (7 cases), and (3) patients undergoing cementless hip replacement (40 cases). Blood samples were taken in groups 1 and 2 at three different occasions; in group 3, prior and 3, 6, 12, 24, and 36 months after surgery. Peripheral leukocytes were separated and left either untreated or challenged with Ti, NiCl2, CoCl2, CrCl3, and phytohemagglutinin. Cell proliferation, cytokine release, and leukocyte migration inhibition assays were performed. Metal-induced reactivity was considered when all three assays showed significant change. Skin patch tests were also carried out. Results Both skin patch tests and leukocyte functional tests were negative in group 1, and both were positive in group 2. In group 3, after 6 months, 12% of the patients showed reactivity to the tested metals except for NiCl2. Following the 36-month period, 18% of group three became sensitive to metals (including all the earlier 12%). In contrast, patch tests were negative at each time point in group 3. Conclusions Orthopedic implant material may induce metal reactivity after implantation in a manner where susceptibility is yet to be elucidated. Leukocyte triple assay technique might be a useful tool to test implant material-related sensitivity.
Collapse
|
19
|
Vasudevan A, DiCarlo EF, Wright T, Chen D, Figgie MP, Goldring SR, Mandl LA. Cellular response to prosthetic wear debris differs in patients with and without rheumatoid arthritis. ACTA ACUST UNITED AC 2011; 64:1005-14. [PMID: 22127818 DOI: 10.1002/art.33459] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
OBJECTIVE To examine whether patients with rheumatoid arthritis (RA) demonstrate patterns of prosthetic wear or cellular responses to implant wear debris different from those demonstrated by patients without inflammatory joint disease. METHODS Thirty-eight patients who had undergone a primary revision of a total elbow arthroplasty for aseptic loosening between 1996 and 2008 were identified. Twenty-five of these patients had RA, and 13 did not have inflammatory arthritis. Clinical data, gross wear patterns of the removed prostheses, and histopathologic analyses of peri-implant tissue were compared between the patients with RA and those without RA. RESULTS Evaluation of the retrieved prostheses showed that conformational change of the humeral polyethylene bushing was associated with the generation of polyethylene and metal particles. The amount and type of wear debris in periprosthetic tissues were similar in patients with and those without RA. Patients with RA who were not receiving anti-tumor necrosis factor (anti-TNF) therapy exhibited a histologic pattern of interstitial and sheet-like lymphocytic infiltrates associated with a high plasma cell composition, which was different from the predominantly perivascular infiltrates with few plasma cells seen in non-RA patients (P = 0.04). Patients with RA who were receiving anti-TNF therapy showed a mixed perivascular and interstitial pattern of infiltrates with variable cell composition. CONCLUSION Patients with RA exhibited a distinct cellular response to implant wear debris compared with patients without RA. This reaction was unrelated to differences in the type or amount of wear debris and was mitigated by anti-TNF therapy. These results suggest an intrinsic alteration in immunoregulation in RA and have implications for potential immunologic treatment of osteolysis in these patients.
Collapse
Affiliation(s)
- Anant Vasudevan
- Yale University School of Medicine, New Haven, Connecticut, USA
| | | | | | | | | | | | | |
Collapse
|
20
|
Carulli C, Villano M, Bucciarelli G, Martini C, Innocenti M. Painful knee arthroplasty: definition and overview. CLINICAL CASES IN MINERAL AND BONE METABOLISM : THE OFFICIAL JOURNAL OF THE ITALIAN SOCIETY OF OSTEOPOROSIS, MINERAL METABOLISM, AND SKELETAL DISEASES 2011; 8:23-25. [PMID: 22461811 PMCID: PMC3279080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Total Knee Arthroplasty (TKA) is one of the most successful procedures in Orthopaedic Surgery, with good clinical results and high survival rate in more than 90% of the cases at long-term follow-up. Since the increase of population's mean age, worsening of articular degenerative alterations, and articular sequelae related to previous fractures, there is a persistent growing of the number of knee arthroplasties in every country each year, with expected increase of complications rates. Painful TKA is considered an unusual complication, but several reports focus on this challenging clinical issue.Common causes of painful TKA may be divided as early or late, and in referred, periarticular or intra-articular. Among the early, we recall implant instability (related to surgical and technical mistakes) and problems of extensor mechanism (patella not resurfaced, malalignment of femoral, tibial, or patellar component, tendons failure or degeneration). Late causes of painful TKA are almost related to aseptic loosening and infection, but also, even if unusual, reflex sympathetic dystrophy, synovitis, and hypersensitivity to metal implants are represented.Hypersensitivity to metal is a clinical issue with significative increase, but to date without a specific characterization. The Authors report about incidence, clinical features, and diagnostic pathways of hypersensitivity to metal implants, focusing on the prevention of this challenging problem.
Collapse
Affiliation(s)
- Christian Carulli
- Address for correspondence: Christian Carulli, MD, First Orthopaedic Clinic, Orthopaedic Traumatologic Center, University of Florence, Largo P. Palagi 1 - 50139 Florence, Italy, Phone: + 39 055 7948287, Fax: + 39 055 432145, E-mail:
| | | | | | | | | |
Collapse
|
21
|
Hosman AH, van der Mei HC, Bulstra SK, Busscher HJ, Neut D. Effects of metal-on-metal wear on the host immune system and infection in hip arthroplasty. Acta Orthop 2010; 81:526-34. [PMID: 20860450 PMCID: PMC3214739 DOI: 10.3109/17453674.2010.519169] [Citation(s) in RCA: 44] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
BACKGROUND AND PURPOSE Joint replacement with metal-on-metal (MOM) bearings have gained popularity in the last decades in young and active patients. However, the possible effects of MOM wear debris and its corrosion products are still the subject of debate. Alongside the potential disadvantages such as toxicity, the influences of metal particles and metal ions on infection risk are unclear. METHODS We reviewed the available literature on the influence of degradation products of MOM bearings in total hip arthroplasties on infection risk. RESULTS Wear products were found to influence the risk of infection by hampering the immune system, by inhibiting or accelerating bacterial growth, and by a possible antibiotic resistance and heavy metal co-selection mechanism. INTERPRETATION Whether or not the combined effects of MOM wear products make MOM bearings less or more prone to infection requires investigation in the near future.
Collapse
Affiliation(s)
| | | | - Sjoerd K Bulstra
- Department of Orthopaedic Surgery, University Medical Center Groningen, Groningen, the Netherlands
| | | | | |
Collapse
|
22
|
Zustin J, Hahn M, Morlock MM, Rüther W, Amling M, Sauter G. Femoral component loosening after hip resurfacing arthroplasty. Skeletal Radiol 2010; 39:747-56. [PMID: 20108086 DOI: 10.1007/s00256-009-0862-z] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/10/2009] [Revised: 11/08/2009] [Accepted: 12/12/2009] [Indexed: 02/02/2023]
Abstract
OBJECTIVE Before the re-introduction of the current generation of total hip resurfacing arthroplasty, component loosening and osteolysis were of great concern to the orthopaedic community. Early, mid- and long-term clinical results are encouraging, but component loosening still exists. MATERIALS AND METHODS Macroscopic, contact radiographic and histopathological analyses after undecalcified preparation of bone tissue specimens were performed. To investigate the frequency and morphological patterns of the loosening of the femoral component, we analysed a series of 190 retrieved femoral remnants that were revised for aseptic failures. RESULTS Thirty-five (18.4%) hips were revised for clinical and/or radiographic loosening of the femoral component. Pseudoarthrosis (n = 17; median in situ time: 16 weeks, interquartile range [IQR]: 9 to 34), collapsed osteonecrosis (n = 5; median in situ time: 79 weeks, IQR: 63 to 97), cement-socket debonding (n = 3; median in situ time: 89 weeks, IQR: 54 to 97) and at later follow-up bone-cement loosening (n = 10; median in situ time: 175 weeks; IQR 112 to 198; p =0.005) were distinct patterns of the femoral remnant-implant loosening. Fibrocartilaginous metaplasia of interface bone trabeculae (n = 38; median in situ time: 61 weeks, IQR: 32 to 138) was strongly associated with femoral component loosening (p = 0.009). Both the trabecular hyperosteoidosis (n = 32; median in situ time: 71 weeks, IQR 50 to 129) and excessive intraosseous lymphocyte infiltration (n = 12; median in situ time: 75 weeks, IQR 51 to 98) at the bone-cement interface correlated strongly with fibrocartilaginous metaplasia (p = 0.001 and p = 0.016 respectively) and all three lesions were associated with the female gender (p = 0.021, p = 0.009, and p = 0.051). CONCLUSION Femoral component loosening at early follow-up was mostly caused by pathological changes of the femoral remnant bone tissue: pseudoarthrosis and collapsed osteonecrosis. Fibrocartilaginous metaplasia was frequently observed in hips with femoral component loosening. The potential role of interface hyperosteoidosis as a precursor lesion of bone-cement loosening and its possible association with delayed type hypersensitivity reaction are discussed.
Collapse
Affiliation(s)
- Jozef Zustin
- Institute of Pathology, University Medical Centre Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.
| | | | | | | | | | | |
Collapse
|