1
|
Ito D, Numano T, Habe T, Okuda S, Nozaki T, Jinzaki M. Fast abdominal magnetic resonance elastography with simultaneous encoding of three-dimensional displacements. Magn Reson Imaging 2024; 108:138-145. [PMID: 38360120 DOI: 10.1016/j.mri.2024.02.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Revised: 02/07/2024] [Accepted: 02/11/2024] [Indexed: 02/17/2024]
Abstract
Three-dimensional (3D) magnetic resonance elastography (MRE) is more accurate than two-dimensional (2D) MRE; however, it requires long-term acquisition. This study aimed to reduce the acquisition time of abdominal 3D MRE using a new sample interval modulation (short-SLIM) approach that can acquire all three motions faster while reducing the prolongation of echo time and flow compensation. To this end, two types of phantom studies and an in vivo test of the liver in three healthy volunteers were performed to compare the performances of conventional spin-echo echo-planar (SE-EPI) MRE, conventional SLIM and short-SLIM. One phantom study measured the mean amplitude and shear modulus within the overall region of a homogeneous phantom by changing the mechanical vibration power to assess the robustness to the lowered phase-to-noise ratio in short-SLIM. The other measured the mean shear modulus in the stiff and background materials of a phantom with an embedded stiffer rod to assess the performance of short-SLIM for complex wave patterns with wave interference. The Spearman's rank correlation coefficient was used to assess similarity of elastograms in the rod-embedded phantom and liver between methods. The results of the phantom study changing the vibration power indicated that there was little difference between conventional MRE and short-SLIM. Moreover, the elastogram pattern and the mean shear modulus in the rod-embedded phantom in conventional SLIM and short-SLIM did not change for conventional MRE; the liver test also showed a small difference between the acquisition techniques. This study demonstrates that short-SLIM can provide MRE results comparable to those of conventional MRE. Short-SLIM can reduce the total acquisition time by a factor of 2.25 compared to conventional 3D MRE time, leading to an improvement in the accuracy of shear modulus estimation by suppressing the patient movements.
Collapse
Affiliation(s)
- Daiki Ito
- Office of Radiation Technology, Keio University Hospital, 35, Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan; Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, 7-2-10, Higashiogu, Arakawa-ku, Tokyo 116-8551, Japan.
| | - Tomokazu Numano
- Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, 7-2-10, Higashiogu, Arakawa-ku, Tokyo 116-8551, Japan; Health Research Institute, National Institute of Advanced Industrial Science and Technology, 1-2-1, Namiki, Tsukuba-shi, Ibaraki 305-8564, Japan
| | - Tetsushi Habe
- Office of Radiation Technology, Keio University Hospital, 35, Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
| | - Shigeo Okuda
- Department of Diagnostic Radiology, National Tokyo Medical Center, 2-5-1, Higashigaoka, Meguro-ku, Tokyo 152-8902, Japan; Department of Radiology, Keio University School of Medicine, 35, Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
| | - Taiki Nozaki
- Department of Radiology, Keio University School of Medicine, 35, Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
| | - Masahiro Jinzaki
- Department of Radiology, Keio University School of Medicine, 35, Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
| |
Collapse
|
2
|
Wang ZH, Zhu L, Xue HD, Jin ZY. Quantitative MR imaging biomarkers for distinguishing inflammatory pancreatic mass and pancreatic cancer-a systematic review and meta-analysis. Eur Radiol 2024:10.1007/s00330-024-10720-9. [PMID: 38639911 DOI: 10.1007/s00330-024-10720-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2023] [Revised: 02/09/2024] [Accepted: 03/14/2024] [Indexed: 04/20/2024]
Abstract
OBJECTIVES To evaluate the diagnostic performance of quantitative magnetic resonance (MR) imaging biomarkers in distinguishing between inflammatory pancreatic masses (IPM) and pancreatic cancer (PC). METHODS A literature search was conducted using PubMed, Embase, the Cochrane Library, and Web of Science through August 2023. Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) was used to evaluate the risk of bias and applicability of the studies. The pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were calculated using the DerSimonian-Laird method. Univariate meta-regression analysis was used to identify the potential factors of heterogeneity. RESULTS Twenty-four studies were included in this meta-analysis. The two main types of IPM, mass-forming pancreatitis (MFP) and autoimmune pancreatitis (AIP), differ in their apparent diffusion coefficient (ADC) values. Compared with PC, the ADC value was higher in MFP but lower in AIP. The pooled sensitivity/specificity of ADC were 0.80/0.85 for distinguishing MFP from PC and 0.82/0.84 for distinguishing AIP from PC. The pooled sensitivity/specificity for the maximal diameter of the upstream main pancreatic duct (dMPD) was 0.86/0.74, with a cutoff of dMPD ≤ 4 mm, and 0.97/0.52, with a cutoff of dMPD ≤ 5 mm. The pooled sensitivity/specificity for perfusion fraction (f) was 0.82/0.68, and 0.82/0.77 for mass stiffness values. CONCLUSIONS Quantitative MR imaging biomarkers are useful in distinguishing between IPM and PC. ADC values differ between MFP and AIP, and they should be separated for consideration in future studies. CLINICAL RELEVANCE STATEMENT Quantitative MR parameters could serve as non-invasive imaging biomarkers for differentiating malignant pancreatic neoplasms from inflammatory masses of the pancreas, and hence help to avoid unnecessary surgery. KEY POINTS • Several quantitative MR imaging biomarkers performed well in differential diagnosis between inflammatory pancreatic mass and pancreatic cancer. • The ADC value could discern pancreatic cancer from mass-forming pancreatitis or autoimmune pancreatitis, if the two inflammatory mass types are not combined. • The diameter of main pancreatic duct had the highest specificity for differentiating autoimmune pancreatitis from pancreatic cancer.
Collapse
Affiliation(s)
- Zi-He Wang
- School of Medicine, Anhui Medical University, Hefei, China
| | - Liang Zhu
- Department of Radiology, Peking Union Medical College Hospital, Shuaifuyuan No. 1, Dongcheng District, Beijing, 100730, China.
| | - Hua-Dan Xue
- Department of Radiology, Peking Union Medical College Hospital, Shuaifuyuan No. 1, Dongcheng District, Beijing, 100730, China.
| | - Zheng-Yu Jin
- Department of Radiology, Peking Union Medical College Hospital, Shuaifuyuan No. 1, Dongcheng District, Beijing, 100730, China
| |
Collapse
|
3
|
Parmar A, Singh K. Motion-artifact-free single shot two-beam optical coherence elastography system. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:025003. [PMID: 38390309 PMCID: PMC10883076 DOI: 10.1117/1.jbo.29.2.025003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2023] [Revised: 01/31/2024] [Accepted: 02/05/2024] [Indexed: 02/24/2024]
Abstract
Significance The assessment of the biomechanical properties of the skin using various imaging techniques has been used as a diagnostic tool in dermatology. Optical coherence elastography (OCE) is one of the techniques that allows for the measurement of elastic properties. OCE relies on measuring tissue displacements induced by external sources. Measuring the tissue's mechanical properties in vivo using OCE is often challenging due to bulk tissue movement. Aim This study aimed to develop an OCE system that allows for minimizing the effects of bulk tissue movements. To achieve this, we designed a two-beam OCE system that simultaneously measures the tissue displacement at two locations on the sample. This allows for cancelling the effect of the tissue bulk movement, which is common to both measurement points. Approach We used a piezoelectric transducer to generate surface acoustic waves (SAW) in the sample. The velocity of the excited waves, which is proportional to the rigidity of the sample, was measured by calculating the phase delay of the SAW at two locations on the sample. Simultaneous measurement at two locations was achieved by dividing a single light beam into two by focusing on the sample at two different locations. The two beams travel different optical path lengths, and the reflected signals were depth encoded in a single optical coherence tomography scan using a single reference beam. Results The system was characterized using different tissue-mimicking phantoms and the skin of healthy volunteers at the wrist and the palm. We achieved an approximately 50-fold increase in phase sensitivity measurement. Conclusions We designed a simple two-beam OCE system that effectively minimizes the effect of tissue movement. We believe that the presented system will find immediate applications in the clinic to monitor the progression of systemic sclerosis disease.
Collapse
Affiliation(s)
- Asha Parmar
- Max-Planck-Institute for the Science of Light, Erlangen, Germany
- Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany
- Friedrich-Alexander-Universität Erlangen-Nürnberg, Department of Experimental Physics, Erlangen, Germany
| | - Kanwarpal Singh
- Max-Planck-Institute for the Science of Light, Erlangen, Germany
- Max-Planck-Zentrum für Physik und Medizin, Erlangen, Germany
- Friedrich-Alexander-Universität Erlangen-Nürnberg, Department of Experimental Physics, Erlangen, Germany
- McMaster University, Department of Electrical and Computer Engineering, Hamilton, Ontario, Canada
| |
Collapse
|
4
|
Burman Ingeberg M, Van Houten E, Zwanenburg JJM. Estimating the viscoelastic properties of the human brain at 7 T MRI using intrinsic MRE and nonlinear inversion. Hum Brain Mapp 2023; 44:6575-6591. [PMID: 37909395 PMCID: PMC10681656 DOI: 10.1002/hbm.26524] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Revised: 10/04/2023] [Accepted: 10/09/2023] [Indexed: 11/03/2023] Open
Abstract
Intrinsic actuation magnetic resonance elastography (MRE) is a phase-contrast MRI technique that allows for in vivo quantification of mechanical properties of the brain by exploiting brain motion that arise naturally due to the cardiac pulse. The mechanical properties of the brain reflect its tissue microstructure, making it a potentially valuable parameter in studying brain disease. The main purpose of this study was to assess the feasibility of reconstructing the viscoelastic properties of the brain using high-quality 7 T MRI displacement measurements, obtained using displacement encoding with stimulated echoes (DENSE) and intrinsic actuation. The repeatability and sensitivity of the method for detecting normal regional variation in brain tissue properties was assessed as secondary goal. The displacement measurements used in this analysis were previously acquired for a separate study, where eight healthy subjects (27 ± 7 years) were imaged with repeated scans (spatial resolution approx. 2 mm isotropic, temporal resolution 75 ms, motion sensitivity 0.35 mm/2π for displacements in anterior-posterior and left-right directions, and 0.7 mm/2π for feet-head displacements). The viscoelastic properties of the brain were estimated using a subzone based non-linear inversion scheme. The results show comparable consistency to that of extrinsic MRE between the viscoelastic property maps obtained from repeated displacement measurements. The shear stiffness maps showed fairly consistent spatial patterns. The whole-brain repeatability coefficient (RC) for shear stiffness was (mean ± standard deviation) 8 ± 8% relative to the mean whole-brain stiffness, and the damping ratio RC was 28 ± 17% relative to the whole-brain damping ratio. The shear stiffness maps showed similar statistically significant regional trends as demonstrated in a publicly available atlas of viscoelastic properties obtained with extrinsic actuation MRE at 50 Hz. The damping ratio maps showed less consistency, likely due to data-model mismatch of describing the brain as a viscoelastic material under low frequencies. While artifacts induced by fluid flow within the brain remain a limitation of the technique in its current state, intrinsic actuation based MRE allow for consistent and repeatable estimation of the mechanical properties of the brain. The method provides enough sensitivity to investigate regional variation in such properties in the normal brain, which is likely sufficient to also investigate pathological changes.
Collapse
|
5
|
Khair AM, McIlvain G, McGarry MDJ, Kandula V, Yue X, Kaur G, Averill LW, Choudhary AK, Johnson CL, Nikam RM. Clinical application of magnetic resonance elastography in pediatric neurological disorders. Pediatr Radiol 2023; 53:2712-2722. [PMID: 37794174 PMCID: PMC11086054 DOI: 10.1007/s00247-023-05779-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2022] [Revised: 09/15/2023] [Accepted: 09/18/2023] [Indexed: 10/06/2023]
Abstract
Magnetic resonance elastography is a relatively new, rapidly evolving quantitative magnetic resonance imaging technique which can be used for mapping the viscoelastic mechanical properties of soft tissues. MR elastography measurements are akin to manual palpation but with the advantages of both being quantitative and being useful for regions which are not available for palpation, such as the human brain. MR elastography is noninvasive, well tolerated, and complements standard radiological and histopathological studies by providing in vivo measurements that reflect tissue microstructural integrity. While brain MR elastography studies in adults are becoming frequent, published studies on the utility of MR elastography in children are sparse. In this review, we have summarized the major scientific principles and recent clinical applications of brain MR elastography in diagnostic neuroscience and discuss avenues for impact in assessing the pediatric brain.
Collapse
Affiliation(s)
| | - Grace McIlvain
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA
| | | | - Vinay Kandula
- Department of Radiology, Nemours Children's Hospital, Wilmington, DE, USA
| | - Xuyi Yue
- Department of Radiology, Nemours Children's Hospital, Wilmington, DE, USA
- Department of Biomedical Research, Nemours Children's Hospital, Wilmington, DE, USA
| | - Gurcharanjeet Kaur
- Department of Neurology, New York-Presbyterian / Columbia University Irving Medical Center, New York, NY, USA
| | - Lauren W Averill
- Department of Radiology, Nemours Children's Hospital, Wilmington, DE, USA
| | - Arabinda K Choudhary
- Department of Radiology, University of Arkansas for Medical Sciences, Little Rock, AR, USA
| | - Curtis L Johnson
- Department of Biomedical Engineering, University of Delaware, Newark, DE, USA
- Department of Biomedical Research, Nemours Children's Hospital, Wilmington, DE, USA
| | - Rahul M Nikam
- Department of Radiology, Nemours Children's Hospital, Wilmington, DE, USA.
| |
Collapse
|
6
|
Gao S, Sun W, Zhang Y, Wang F, Jin K, Qian X, Han J, Wang X, Dai Y, Sheng R, Zeng M. Correlation analysis of MR elastography and Ki-67 expression in intrahepatic cholangiocarcinoma. Insights Imaging 2023; 14:204. [PMID: 38001349 PMCID: PMC10673794 DOI: 10.1186/s13244-023-01559-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Accepted: 11/01/2023] [Indexed: 11/26/2023] Open
Abstract
BACKGROUND Intrahepatic cholangiocarcinoma (iCCA) is an aggressive primary liver cancer with dismal outcome, high Ki-67 expression is associated with active progression and poor prognosis of iCCA, the application of MRE in the prediction of iCCA Ki-67 expression has not yet been investigated until now. We aimed to evaluate the value of magnetic resonance elastography (MRE) in assessing Ki-67 expression for iCCA. RESULTS In the whole cohort, 97 patients (57 high Ki-67 and 40 low Ki-67; 58 males, 39 females; mean age, 58.89 years, ranges 36-70 years) were included. At the multivariate analysis, tumor stiffness (odds ratio (OR) = 1.669 [95% CI: 1.307-2.131], p < 0.001) and tumor apparent diffusion coefficient (ADC) (OR = 0.030 [95% CI: 0.002, 0.476], p = 0.013) were independent significant variables associated with Ki-67. Areas under the curve of tumor stiffness for the identification of high Ki-67 were 0.796 (95% CI 0.702, 0.871). Tumor stiffness was moderately correlated with Ki-67 level (r = 0.593, p < 0.001). When both predictive variables of tumor stiffness and ADC were integrated, the best performance was achieved with area under the curve values of 0.864 (95% CI 0.780-0.926). CONCLUSION MRE-based tumor stiffness correlated with Ki-67 in iCCA and could be investigated as a potential prognostic biomarker. The combined model incorporating both tumor stiffness and ADC increased the predictive performance. CRITICAL RELEVANCE STATEMENT MRE-based tumor stiffness might be a surrogate imaging biomarker to predict Ki-67 expression in intrahepatic cholangiocarcinoma patients, reflecting tumor cellular proliferation. The combined model incorporating both tumor stiffness and apparent diffusion coefficient increased the predictive performance. KEY POINTS • MRE-based tumor stiffness shows a significant correlation with Ki-67. • The combined model incorporating tumor stiffness and apparent diffusion coefficient demonstrated an optimized predictive performance for Ki-67 expression. • MRE-based tumor stiffness could be investigated as a potential prognostic biomarker for intrahepatic cholangiocarcinoma.
Collapse
Affiliation(s)
- Shanshan Gao
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Wei Sun
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Yunfei Zhang
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Central Research Institute, United Imaging Healthcare, Shanghai, 201800, China
| | - Feihang Wang
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Department of Interventional Radiology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Kaipu Jin
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Xianling Qian
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
| | - Jing Han
- Department of Pathology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Xiaolin Wang
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China
- Department of Interventional Radiology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China
| | - Yongming Dai
- Central Research Institute, United Imaging Healthcare, Shanghai, 201800, China
| | - Ruofan Sheng
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China.
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China.
- Department of Radiology, Zhongshan Hospital (Xiamen), Fudan University, Fujian, 361006, China.
| | - Mengsu Zeng
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai, 200032, China.
- Shanghai Institute of Medical Imaging, Shanghai, 200032, China.
- Department of Cancer Center, Zhongshan Hospital, Fudan University, Shanghai, 200032, China.
| |
Collapse
|
7
|
Bhuiyan EH, Ozkaya E, Kennedy P, Del Hoyo JL, Achkar BE, Thung S, Lewis S, Bane O, Taouli B. Magnetic resonance elastography for noninvasive detection of liver fibrosis: is there an added value of 3D acquisition? Abdom Radiol (NY) 2023; 48:3420-3429. [PMID: 37700185 DOI: 10.1007/s00261-023-04036-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Revised: 08/22/2023] [Accepted: 08/24/2023] [Indexed: 09/14/2023]
Abstract
PURPOSE (1) Assess the diagnostic performance of liver 3D magnetic resonance elastography (MRE) parameters (including stiffness, storage/loss modulus and damping ratio) compared to liver stiffness measured with 2D MRE for noninvasive detection of advanced liver fibrosis (F3-F4) and cirrhosis (F4) in patients with chronic liver disease. (2) Assess the value of serum markers (FIB-4) in detecting advanced liver fibrosis and cirrhosis in the same patients. METHODS This was a single center, prospective IRB-approved cross-sectional study that included 49 patients (M/F: 23/26, mean age 50.8 y) with chronic liver disease and concomitant liver biopsy. MRE was acquired at 1.5T using a spin echo-EPI sequence. The following parameters were measured: liver stiffness using 2D MRE (LS-2D) and 3D MRE parameters (LS-3D, liver storage, loss modulus and damping ratio). The Mann-Whitney U test, ROC curve analysis, Spearman correlation and logistic regression were performed to evaluate diagnostic performance of MRE parameters and FIB-4. RESULTS LS-2D and LS-3D had similar diagnostic performance for diagnosis of F3-F4, with AUCs of 0.87 and 0.88, sensitivity of 0.71 and 0.81, specificity of 0.89 for both. For diagnosis of F4, LS-2D and LS-3D had similar performance with AUCs of 0.81 for both, sensitivity of 0.75 and 0.83, and specificity of 0.84 and 0.73, respectively. Additional 3D parameters (storage modulus, loss modulus, damping ratio) had variable performance, with AUC range of 0.59-0.78 for F3-F4; and 0.52-0.70 for F4. FIB-4 had lower diagnostic performance, with AUCs of 0.66 for F3-F4, and 0.68 for F4. CONCLUSION Our study shows no added value of 3D MRE compared to 2D MRE for detection of advanced fibrosis and cirrhosis, while FIB-4 had lower diagnostic performance.
Collapse
Affiliation(s)
- Enamul H Bhuiyan
- BioMedical Engineering and Imaging Institute (BMEII), Icahn School of Medicine at Mount Sinai, New York, NY, USA
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Efe Ozkaya
- BioMedical Engineering and Imaging Institute (BMEII), Icahn School of Medicine at Mount Sinai, New York, NY, USA
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Paul Kennedy
- BioMedical Engineering and Imaging Institute (BMEII), Icahn School of Medicine at Mount Sinai, New York, NY, USA
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Juan Lloret Del Hoyo
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
- Department of Radiology, NYU Grossman School of Medicine, New York, NY, USA
| | - Bassam El Achkar
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Swan Thung
- Department of Pathology, Molecular and Cell-Based Medicine, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Sara Lewis
- BioMedical Engineering and Imaging Institute (BMEII), Icahn School of Medicine at Mount Sinai, New York, NY, USA
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Octavia Bane
- BioMedical Engineering and Imaging Institute (BMEII), Icahn School of Medicine at Mount Sinai, New York, NY, USA
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Bachir Taouli
- BioMedical Engineering and Imaging Institute (BMEII), Icahn School of Medicine at Mount Sinai, New York, NY, USA.
- Department of Diagnostic, Molecular and Interventional Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA.
| |
Collapse
|
8
|
van Schelt AS, Beek KJ, Wassenaar NPM, Schrauben EM, Runge JH, Gecse KB, van der Bilt JDW, Neefjes-Borst EA, Buskens CJ, Nederveen AJ, Stoker J. Viscoelastic properties of small bowel mesentery at MR elastography in Crohn's disease: a prospective cross-sectional exploratory study. Eur Radiol Exp 2023; 7:53. [PMID: 37718360 PMCID: PMC10505604 DOI: 10.1186/s41747-023-00366-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Accepted: 06/22/2023] [Indexed: 09/19/2023] Open
Abstract
BACKGROUND Creeping fat is a pathological feature of small bowel Crohn's disease (CD), with literature suggesting that bowel resection with extended mesenteric resection is related to less postoperative recurrences. Conventional imaging is unable to accurately quantify the disease involvement (i.e., fibrosis) of creeping fat. Quantification of disease involvement could be useful in decision-making for additional extended mesenteric resection. We investigated the feasibility of magnetic resonance elastography (MRE) of the mesentery and if MRE is capable to detect fibrotic disease involvement of mesentery in active CD. METHODS Multifrequency MRE yielded spatial stiffness (shear wave speed, SWS, |G*|) and fluidity maps (φ). Viscoelastic properties of seven CD patients' mesentery were compared to age- and sex-matched healthy volunteers (HV) (Mann-Whitney U-test). Within CD patients, the affected and "presumably" unaffected mesentery were compared (Wilcoxon-signed rank test). Repeatability was tested in 15 HVs (Bland-Altman analysis, coefficient of variation [CoV]). Spearman rank correlations were used to investigate the relation between microscopically scored amount of mesenteric fibrosis and viscoelastic parameters. RESULTS SWS, |G*|, and φ of affected mesentery in CD were higher compared to HV (p = 0.017, p = 0.001, p = 0.017). Strong correlations were found between percentage of area of mesenteric fibrosis and SWS and |G*| (p < 0.010). No differences were found within CD between affected and presumably unaffected mesentery. Repeatability of SWS showed 95% limits of agreement of (-0.09, 0.13 m/s) and within-subject CoV of 5.3%. CONCLUSION MRE may have the potential to measure fibrotic disease involvement of the mesentery in CD, possibly guiding clinical decision-making with respect to extended mesenteric resection. TRIAL REGISTRATION Dutch trial register, NL9105 , registered 7 December 2020. RELEVANCE STATEMENT MRE may have the potential to measure the amount of mesenteric fibrosis of the affected mesenteric fat in active Crohn's disease, giving more insight into disease progression and could potentially play a role in clinical decision-making for extended mesenteric resection. KEY POINTS • MRE of the mesentery in patients with active CD is feasible. • Fluidity and stiffness of the mesentery increase in active CD, while stiffness correlates with the histopathological amount of mesenteric fibrosis. • MRE provides biomarkers to quantify mesenteric disease activity in active CD.
Collapse
Affiliation(s)
- Anne-Sophie van Schelt
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
- Cancer Center Amsterdam, Imaging and Biomarkers, Amsterdam, The Netherlands
| | - Kim Johanna Beek
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands.
- Amsterdam Gastroenterology, Endocrinology, Metabolism, Amsterdam, The Netherlands.
| | - Nienke Petronella Maria Wassenaar
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
- Cancer Center Amsterdam, Imaging and Biomarkers, Amsterdam, The Netherlands
| | - Eric M Schrauben
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Jurgen H Runge
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
- Department of Radiology, Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Krisztina Barbara Gecse
- Amsterdam Gastroenterology, Endocrinology, Metabolism, Amsterdam, The Netherlands
- Department of Gastroenterology and Hepatology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Jarmila D W van der Bilt
- Amsterdam Gastroenterology, Endocrinology, Metabolism, Amsterdam, The Netherlands
- Department of Surgery, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - E Andra Neefjes-Borst
- Amsterdam Gastroenterology, Endocrinology, Metabolism, Amsterdam, The Netherlands
- Department of Pathology, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Christianne Johanna Buskens
- Amsterdam Gastroenterology, Endocrinology, Metabolism, Amsterdam, The Netherlands
- Department of Surgery, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Aart J Nederveen
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Jaap Stoker
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
- Cancer Center Amsterdam, Imaging and Biomarkers, Amsterdam, The Netherlands
- Amsterdam Gastroenterology, Endocrinology, Metabolism, Amsterdam, The Netherlands
| |
Collapse
|
9
|
Hashemi HS, Mohammed SK, Zeng Q, Azar RZ, Rohling RN, Salcudean SE. 3-D Ultrafast Shear Wave Absolute Vibro-Elastography Using a Matrix Array Transducer. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2023; 70:1039-1053. [PMID: 37235463 DOI: 10.1109/tuffc.2023.3280450] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Real-time ultrasound imaging plays an important role in ultrasound-guided interventions. The 3-D imaging provides more spatial information compared to conventional 2-D frames by considering the volumes of data. One of the main bottlenecks of 3-D imaging is the long data acquisition time, which reduces practicality and can introduce artifacts from unwanted patient or sonographer motion. This article introduces the first shear wave absolute vibro-elastography (S-WAVE) method with real-time volumetric acquisition using a matrix array transducer. In S-WAVE, an external vibration source generates mechanical vibrations inside the tissue. The tissue motion is then estimated and used in solving a wave equation inverse problem to provide the tissue elasticity. A matrix array transducer is used with a Verasonics ultrasound machine and a frame rate of 2000 volumes/s to acquire 100 radio frequency (RF) volumes in 0.05 s. Using plane wave (PW) and compounded diverging wave (CDW) imaging methods, we estimate axial, lateral, and elevational displacements over 3-D volumes. The curl of the displacements is used with local frequency estimation to estimate elasticity in the acquired volumes. Ultrafast acquisition extends substantially the possible S-WAVE excitation frequency range, now up to 800 Hz, enabling new tissue modeling and characterization. The method was validated on three homogeneous liver fibrosis phantoms and on four different inclusions within a heterogeneous phantom. The homogeneous phantom results show less than 8% (PW) and 5% (CDW) difference between the manufacturer values and the corresponding estimated values over a frequency range of 80-800 Hz. The estimated elasticity values for the heterogeneous phantom at 400-Hz excitation frequency show the average errors of 9% (PW) and 6% (CDW) compared to the provided average values by magnetic resonance elastography (MRE). Furthermore, both imaging methods were able to detect the inclusions within the elasticity volumes. An ex vivo study on a bovine liver sample shows less than 11% (PW) and 9% (CDW) difference between the estimated elasticity ranges by the proposed method and the elasticity ranges provided by MRE and acoustic radiation force impulse (ARFI).
Collapse
|
10
|
Leartprapun N, Zeng Z, Hajjarian Z, Bossuyt V, Nadkarni SK. Speckle rheological spectroscopy reveals wideband viscoelastic spectra of biological tissues. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.06.08.544037. [PMID: 37333220 PMCID: PMC10274797 DOI: 10.1101/2023.06.08.544037] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/20/2023]
Abstract
Mechanical transformation of tissue is not merely a symptom but a decisive driver in pathological processes. Comprising intricate network of cells, fibrillar proteins, and interstitial fluid, tissues exhibit distinct solid-(elastic) and liquid-like (viscous) behaviours that span a wide band of frequencies. Yet, characterization of wideband viscoelastic behaviour in whole tissue has not been investigated, leaving a vast knowledge gap in the higher frequency range that is linked to fundamental intracellular processes and microstructural dynamics. Here, we present wideband Speckle rHEologicAl spectRoScopy (SHEARS) to address this need. We demonstrate, for the first time, analysis of frequency-dependent elastic and viscous moduli up to the sub-MHz regime in biomimetic scaffolds and tissue specimens of blood clots, breast tumours, and bone. By capturing previously inaccessible viscoelastic behaviour across the wide frequency spectrum, our approach provides distinct and comprehensive mechanical signatures of tissues that may provide new mechanobiological insights and inform novel disease prognostication.
Collapse
Affiliation(s)
- Nichaluk Leartprapun
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114 USA
| | - Ziqian Zeng
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114 USA
| | - Zeinab Hajjarian
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114 USA
| | - Veerle Bossuyt
- Department of Pathology, Massachusetts General Hospital, Boston, MA 02114 USA
| | - Seemantini K. Nadkarni
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114 USA
| |
Collapse
|
11
|
Darwish OI, Gharib AM, Jeljeli S, Metwalli NS, Feeley J, Rotman Y, Brown RJ, Ouwerkerk R, Kleiner DE, Stäb D, Speier P, Sinkus R, Neji R. Single Breath-Hold 3-Dimensional Magnetic Resonance Elastography Depicts Liver Fibrosis and Inflammation in Obese Patients. Invest Radiol 2023; 58:413-419. [PMID: 36719974 PMCID: PMC10735168 DOI: 10.1097/rli.0000000000000952] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
OBJECTIVES Three-dimensional (3D) magnetic resonance elastography (MRE) measures liver fibrosis and inflammation but requires several breath-holds that hamper clinical acceptance. The aim of this study was to evaluate the technical and clinical feasibility of a single breath-hold 3D MRE sequence as a means of measuring liver fibrosis and inflammation in obese patients. METHODS From November 2020 to December 2021, subjects were prospectively enrolled and divided into 2 groups. Group 1 included healthy volunteers (n = 10) who served as controls to compare the single breath-hold 3D MRE sequence with a multiple-breath-hold 3D MRE sequence. Group 2 included liver patients (n = 10) who served as participants to evaluate the clinical feasibility of the single breath-hold 3D MRE sequence in measuring liver fibrosis and inflammation. Controls and participants were scanned at 60 Hz mechanical excitation with the single breath-hold 3D MRE sequence to retrieve the magnitude of the complex-valued shear modulus (|G*| [kPa]), the shear wave speed (Cs [m/s]), and the loss modulus (G" [kPa]). The controls were also scanned with a multiple-breath-hold 3D MRE sequence for comparison, and the participants had histopathology (Ishak scores) for correlation with Cs and G". RESULTS For the 10 controls, 5 were female, and the mean age and body mass index were 33.1 ± 9.5 years and 23.0 ± 2.1 kg/m 2 , respectively. For the 10 participants, 8 were female, and the mean age and body mass index were 45.1 ± 16.5 years and 33.1 ± 4.0 kg/m 2 (obese range), respectively. All participants were suspected of having nonalcoholic fatty liver disease. Bland-Altman analysis of the comparison in controls shows there are nonsignificant differences in |G*|, Cs, and G" below 6.5%, suggesting good consensus between the 2 sequences. For the participants, Cs and G" correlated significantly with Ishak fibrosis and inflammation grades, respectively ( ρ = 0.95, P < 0.001, and ρ = 0.84, P = 0.002). CONCLUSION The single breath-hold 3D MRE sequence may be effective in measuring liver fibrosis and inflammation in obese patients.
Collapse
Affiliation(s)
- Omar Isam Darwish
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
- INSERM U1148, LVTS, University Paris Diderot, Paris, France
- MR Research Collaborations, Siemens Healthcare Limited, Frimley, United Kingdom
| | - Ahmed M. Gharib
- National Institute of Diabetes and Digestive and Kidney Diseases, Bethesda, MD
| | - Sami Jeljeli
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
| | - Nader S. Metwalli
- National Institute of Diabetes and Digestive and Kidney Diseases, Bethesda, MD
| | - Jenna Feeley
- National Institute of Diabetes and Digestive and Kidney Diseases, Bethesda, MD
| | - Yaron Rotman
- National Institute of Diabetes and Digestive and Kidney Diseases, Bethesda, MD
| | - Rebecca J. Brown
- National Institute of Diabetes and Digestive and Kidney Diseases, Bethesda, MD
| | - Ronald Ouwerkerk
- National Institute of Diabetes and Digestive and Kidney Diseases, Bethesda, MD
| | | | - Daniel Stäb
- MR Research Collaborations, Siemens Healthcare Limited, Melbourne, Australia
| | - Peter Speier
- MR Application Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany
| | - Ralph Sinkus
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
- INSERM U1148, LVTS, University Paris Diderot, Paris, France
| | - Radhouene Neji
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
- MR Research Collaborations, Siemens Healthcare Limited, Frimley, United Kingdom
| |
Collapse
|
12
|
Long L, Liu M, Deng X, Cao M, Zhang J, Lan X, Zhang J. 3D multifrequency magnetic resonance elastography in distinguishing endometrial and cervical adenocarcinoma. Magn Reson Imaging 2023; 102:62-68. [PMID: 37146780 DOI: 10.1016/j.mri.2023.05.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2023] [Revised: 04/25/2023] [Accepted: 05/02/2023] [Indexed: 05/07/2023]
Abstract
OBJECTIVES To prospectively evaluate the value of tomoelastography in determining the underlying origins of uterine adenocarcinoma. METHODS This prospective work was approved by our institutional review board, and all patients provided informed consent. 64 patients with histopathologically confirmed adenocarcinomas originated either from the cervix (CAC: cervical adenocarcinoma) or endometrium (EAC: endometrial adenocarcinoma) underwent MRI and tomoelastography examination on a 3.0 T MR scanner. To biomechanically characterize the adenocarcinoma, two MRE-derived parameters maps were provided in the tomoelastography, namely shear wave speed (c, m/s) and loss angle (φ, radian), which represented the stiffness and fluidity, respectively. The MRE-derived parameters were compared by using a two-tailed independent-sample t-test or Mann-Whitney U test. Five morphologic features were also analyzed by using the χ2 test. Logistic regression analysis was used to develop diagnosis models. Delong test was used to compare the receiver operating characteristic curves whith different diagnostic models and evaluate the diagnostic efficiency. RESULTS CAC were significantly stiffer and behaved more fluid like than EAC (c: 2.58 ± 0.62 m/s vs.2.17 ± 0.72 m/s, p = 0.029, φ, 0.97 ± 0.19 rad vs.0.73 ± 0.26 rad, p < 0.0001). The diagnostic performance for distinguishing CAC from EAC was similar for c (AUC = 0.71) and for φ (AUC = 0.75). For distinguishing CAC from EAC, the AUC of tumor location was the higher than c and φ (AUC = 0.80). A cmobined model consisting of tumor location, c, and φ achieved the best diagnostic performance, with an AUC of 0.88 (77.27% sensitivity and 85.71% specificity). CONCLUSIONS CAC and EAC displayed their unique biomechanical features. 3D multifrequency MRE provided added value to the conventional morphologic features in distinguishing the two types of diseases.
Collapse
Affiliation(s)
- Ling Long
- Department of Radiology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, Chongqing 400030, PR China
| | - Meiling Liu
- Department of Radiology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, Chongqing 400030, PR China
| | - Xijia Deng
- Department of Radiology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, Chongqing 400030, PR China
| | - Meimei Cao
- Department of Radiology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, Chongqing 400030, PR China
| | - Jing Zhang
- Department of Radiology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, Chongqing 400030, PR China
| | - Xiaosong Lan
- Department of Radiology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, Chongqing 400030, PR China
| | - Jiuquan Zhang
- Department of Radiology, Chongqing University Cancer Hospital & Chongqing Cancer Institute & Chongqing Cancer Hospital, Chongqing 400030, PR China.
| |
Collapse
|
13
|
Rebelo R, Xavier CPR, Giovannetti E, Vasconcelos MH. Fibroblasts in pancreatic cancer: molecular and clinical perspectives. Trends Mol Med 2023; 29:439-453. [PMID: 37100646 DOI: 10.1016/j.molmed.2023.03.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 03/14/2023] [Accepted: 03/16/2023] [Indexed: 04/28/2023]
Abstract
Pancreatic stellate cells (PSCs) and cancer-associated fibroblasts (CAFs) are highly abundant cells in the pancreatic tumor microenvironment (TME) that modulate desmoplasia. The formation of a dense stroma leads to immunosuppression and therapy resistance that are major causes of treatment failure in pancreatic ductal adenocarcinoma (PDAC). Recent evidence suggests that several subpopulations of CAFs in the TME can interconvert, explaining the dual roles (antitumorigenic and protumorigenic) of CAFs in PDAC and the contradictory results of CAF-targeted therapies in clinical trials. This highlights the need to clarify CAF heterogeneity and their interactions with PDAC cells. This review focuses on the communication between activated PSCs/CAFs and PDAC cells, as well as on the mechanisms underlying this crosstalk. CAF-focused therapies and emerging biomarkers are also outlined.
Collapse
Affiliation(s)
- Rita Rebelo
- Instituto de Investigação e Inovação em Saúde (i3S), University of Porto, 4200-135 Porto, Portugal; Cancer Drug Resistance Group, Institute of Molecular Pathology and Immunology (IPATIMUP), University of Porto, 4200-135 Porto, Portugal; Department of Biological Sciences, Faculty of Pharmacy of the University of Porto (FFUP), Porto, Portugal
| | - Cristina P R Xavier
- Instituto de Investigação e Inovação em Saúde (i3S), University of Porto, 4200-135 Porto, Portugal; Cancer Drug Resistance Group, Institute of Molecular Pathology and Immunology (IPATIMUP), University of Porto, 4200-135 Porto, Portugal
| | - Elisa Giovannetti
- Department of Medical Oncology, Cancer Center Amsterdam, Amsterdam University Medical Center (UMC), Vrije Universiteit Amsterdam, Amsterdam, The Netherlands; Fondazione Pisana per La Scienza, Pisa, Italy
| | - M Helena Vasconcelos
- Instituto de Investigação e Inovação em Saúde (i3S), University of Porto, 4200-135 Porto, Portugal; Cancer Drug Resistance Group, Institute of Molecular Pathology and Immunology (IPATIMUP), University of Porto, 4200-135 Porto, Portugal; Department of Biological Sciences, Faculty of Pharmacy of the University of Porto (FFUP), Porto, Portugal.
| |
Collapse
|
14
|
Multi-frequency shear modulus measurements discriminate tumorous from healthy tissues. J Mech Behav Biomed Mater 2023; 140:105721. [PMID: 36791572 DOI: 10.1016/j.jmbbm.2023.105721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Revised: 02/07/2023] [Accepted: 02/08/2023] [Indexed: 02/11/2023]
Abstract
As far as their mechanical properties are concerned, cancerous lesions can be confused with healthy surrounding tissues in elastography protocols if only the magnitude of moduli is considered. We show that the frequency dependence of the tissue's mechanical properties allows for discriminating the tumor from other tissues, obtaining a good contrast even when healthy and tumor tissues have shear moduli of comparable magnitude. We measured the shear modulus G*(ω) of xenograft subcutaneous tumors developed in mice using breast human cancer cells, compared with that of fat, skin and muscle harvested from the same mice. As the absolute shear modulus |G*(ω)| of tumors increases by 42% (from 5.2 to 7.4 kPa) between 0.25 and 63 Hz, it varies over the same frequency range by 77% (from 0.53 to 0.94 kPa) for the fat, by 103% (from 3.4 to 6.9 kPa) for the skin and by 120% (from 4.4 to 9.7 kPa) for the muscle. These measurements fit well to the fractional model G*(ω)=K(iω)n, yielding a coefficient K and a power-law exponent n for each sample. Tumor, skin and muscle have comparable K parameter values, that of fat being significantly lower; the p-values given by a Mann-Whitney test are above 0.14 when comparing tumor, skin and muscle between themselves, but below 0.001 when comparing fat with tumor, skin or muscle. With regards the n parameter, tumor and fat are comparable, with p-values above 0.43, whereas tumor differs from both skin and muscle, with p-values below 0.001. Tumor tissues thus significantly differs from fat, skin and muscle on account of either the K or the n parameter, i.e. of either the magnitude or the frequency-dependence of the shear modulus.
Collapse
|
15
|
Ogino Y, Wakui N, Nagai H, Matsuda T. Comparison of strain elastography and shear wave elastography in diagnosis of fibrosis in nonalcoholic fatty liver disease. J Med Ultrason (2001) 2023; 50:187-195. [PMID: 36801991 DOI: 10.1007/s10396-023-01293-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Accepted: 01/12/2023] [Indexed: 02/21/2023]
Abstract
PURPOSE To reveal the ability of S-Map strain elastography to diagnose fibrosis in nonalcoholic fatty liver disease (NAFLD) and to compare its diagnostic ability with that of shear wave elastography (SWE). METHODS Participants were patients with NAFLD who were scheduled to undergo liver biopsy at our institution between 2015 and 2019. A GE Healthcare LOGIQ E9 ultrasound system was used. For S-Map, the right lobe of the liver was visualized in the section where the heartbeat was detected by right intercostal scanning, a 4 × 2-cm region of interest (ROI) was defined at 5 cm from the liver surface, and ROI strain images were acquired. Measurements were repeated six times, with the average taken as the S-Map value. Correlations of S-Map and SWE values with fibrosis stage determined by liver biopsy were analyzed using multiple comparisons. The diagnostic performance of S-Map for fibrosis staging was assessed using receiver operating characteristic curves. RESULTS In total, 107 patients (65 men, 42 women; mean age 51 ± 14 years) were analyzed. The S-Map value by fibrosis stage was 34.4 ± 10.9 for F0, 32.9 ± 9.1 for F1, 29.5 ± 5.6 for F2, 26.7 ± 6.0 for F3, and 22.8 ± 4.19 for F4. By fibrosis stage, the SWE value was 1.27 ± 0.25 for F0, 1.39 ± 0.20 for F1, 1.59 ± 0.20 for F2, 1.64 ± 0.17 for F3, and 1.88 ± 0.19 for F4. The diagnostic performance of S-Map (measured by area under the curve) was 0.75 for F2, 0.80 for F3, and 0.85 for F4. The diagnostic performance of SWE (measured by area under the curve) was 0.88 for F2, 0.87 for F3, and 0.92 for F4. CONCLUSION S-Map strain elastography was inferior to SWE in terms of ability to diagnose fibrosis in NAFLD.
Collapse
Affiliation(s)
- Yu Ogino
- Division of Gastroenterology and Hepatology, Department of Internal Medicine (Omori), School of Medicine, Faculty of Medicine, Toho University, 6-11-1 Omori-Nishi, Ota-Ku, Tokyo, 143-8541, Japan
| | - Noritaka Wakui
- Division of Gastroenterology and Hepatology, Department of Internal Medicine (Omori), School of Medicine, Faculty of Medicine, Toho University, 6-11-1 Omori-Nishi, Ota-Ku, Tokyo, 143-8541, Japan.
| | - Hidenari Nagai
- Division of Gastroenterology and Hepatology, Department of Internal Medicine (Omori), School of Medicine, Faculty of Medicine, Toho University, 6-11-1 Omori-Nishi, Ota-Ku, Tokyo, 143-8541, Japan
| | - Takahisa Matsuda
- Division of Gastroenterology and Hepatology, Department of Internal Medicine (Omori), School of Medicine, Faculty of Medicine, Toho University, 6-11-1 Omori-Nishi, Ota-Ku, Tokyo, 143-8541, Japan
| |
Collapse
|
16
|
Kaplan JM, Alexis J, Grimaldi G, Islam M, Izard SM, Lee TP. A comparison of magnetic resonance elastography (MRE) to biomarker testing for staging fibrosis in non-alcoholic fatty liver disease (NAFLD). Transl Gastroenterol Hepatol 2023; 8:7. [PMID: 36704653 PMCID: PMC9813653 DOI: 10.21037/tgh-22-27] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Accepted: 07/29/2022] [Indexed: 01/29/2023] Open
Abstract
Background Non-alcoholic fatty liver disease (NAFLD) is the world's most prevalent chronic liver disease. In advanced stages, it is associated with significant morbidity and mortality. Magnetic resonance elastography (MRE) and scoring panels Fibrosis-4 (FIB-4) and NAFLD Fibrosis Score (NFS) are useful noninvasive alternatives to liver biopsy for fibrosis staging. Our study aimed to determine how well MRE corresponds with both FIB-4 and NFS at different stages of fibrosis. Methods We performed a retrospective chart review of patients age ≥18 with NAFLD as their only known liver disease who underwent MRE within six months of a lab draw. MRE stratified patients into fibrosis stages using kPa values. FIB-4 categorized patients as Advanced Fibrosis Excluded, Further Investigation Needed or Advanced Fibrosis Likely. NFS categorized them as F0-2, Indeterminate or F3-4. MRE fibrosis staging was compared to FIB-4 and NFS for both ruling out advanced fibrosis and identifying advanced fibrosis/cirrhosis. Results Overall, 193 patients met inclusion criteria. Our statistical analysis included calculating positive predictive values (PPVs) and negative predictive values (NPVs), which are the proportions of positive and negative fibrosis screening results that correspond to positive and negative MRE results respectively. NPV for FIB-4 (0.84) and NFS (0.89) in the 'rule out advanced fibrosis' category signify that 84% and 89% of respective biomarker scores correspond to MRE in early stage disease. The PPV for FIB-4 and NFS in the 'identify advanced fibrosis/cirrhosis' category signify 63% and 72% of respective biomarker scores correspond to MRE in late stage disease. Conclusions FIB-4 and NFS scores indicating little to no fibrosis correspond extremely well with MRE, while scores suggesting advanced fibrosis/cirrhosis correspond less convincingly. MRE shows promise as an effective alternative to liver biopsy, however our study suggests FIB-4 and NFS alone may be sufficient for fibrosis staging, particularly in early stage NAFLD.
Collapse
Affiliation(s)
- Joseph M. Kaplan
- Department of Medicine, University of Pittsburgh Medical Center, Pittsburgh, PA, USA
| | - Jamil Alexis
- Department of Gastroenterology, Yale New Haven Health Bridgeport Hospital, Bridgeport, CT, USA
| | - Gregory Grimaldi
- Department of Radiology, Hofstra School of Medicine/Northwell Health, Manhasset, NY, USA
| | - Mohammed Islam
- Department of Medicine, Hofstra School of Medicine/Northwell Health, Manhasset, NY, USA
| | - Stephanie M. Izard
- Department of Medicine, Northwell Health Center for Health Innovations and Outcomes Research, Manhasset, NY, USA
| | - Tai-Ping Lee
- Division of Hepatology, Hofstra School of Medicine/Northwell Health, Manhasset, NY, USA
| |
Collapse
|
17
|
Ghafarinatanzi M, Perie D. Estimation of anisotropic properties of CMR patient-specific left ventricle using the virtual field method. Biomech Model Mechanobiol 2023; 22:695-710. [PMID: 36692846 DOI: 10.1007/s10237-022-01675-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2022] [Accepted: 12/08/2022] [Indexed: 01/25/2023]
Abstract
Left ventricle (LV) myocardial dysfunction has been recently investigated using the estimation of isotropic myocardial stiffness from magnetic resonance imaging (MRI). However, Myocardium is known to have a 3D complex geometry with anisotropic stiffness. The assessment of the anisotropy properties characterizes structural changes in myocardium as a consequence of heart failure (HF). From image data, the virtual field method (VFM) can determine material stiffness in a non-invasive manner. In the present work, the objective is to compare two inverse identification methods, given the isotropic and anisotropic models in the characterization of properties of myocardium in acute lymphoblastic leukemia (ALL) survivors using VFM and MRI. Two types of VFM approach are presented. Using the first, the virtual displacements (VFs) allow whole-field LV to be imposed into VFM formulation and caused to directly estimate two independent parameters from isotropic constitutive relation. With the second, anisotropic parameters are estimated using piece-wise (Finite element-based) VFM. The resulting values showed significant differences between the subjects in comparative study of leukemia survivors, and variance in estimated parameters by two different VFM approach. This approach would be an efficient tool to characterize early cardiac dysfunction. This work elucidates the benefits and shortcomings of using VFM to determine anisotropic parameters of LV myocardium in linear elastic and of using the FEM application to generate meshes of patient-specific LVs from MRI images.
Collapse
Affiliation(s)
- Mehdi Ghafarinatanzi
- Department of Mechanical Engineering, Polytechnique Montreal, Station Centre-Ville, P.O. Box 6079, Montréal, QC, H3C 3A7, Canada. .,Sainte-Justine University Health Center, Research Center, Montreal, Canada.
| | - Delphine Perie
- Department of Mechanical Engineering, Polytechnique Montreal, Station Centre-Ville, P.O. Box 6079, Montréal, QC, H3C 3A7, Canada.,Sainte-Justine University Health Center, Research Center, Montreal, Canada
| |
Collapse
|
18
|
Leartprapun N, Adie SG. Recent advances in optical elastography and emerging opportunities in the basic sciences and translational medicine [Invited]. BIOMEDICAL OPTICS EXPRESS 2023; 14:208-248. [PMID: 36698669 PMCID: PMC9842001 DOI: 10.1364/boe.468932] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 11/29/2022] [Accepted: 11/29/2022] [Indexed: 05/28/2023]
Abstract
Optical elastography offers a rich body of imaging capabilities that can serve as a bridge between organ-level medical elastography and single-molecule biophysics. We review the methodologies and recent developments in optical coherence elastography, Brillouin microscopy, optical microrheology, and photoacoustic elastography. With an outlook toward maximizing the basic science and translational clinical impact of optical elastography technologies, we discuss potential ways that these techniques can integrate not only with each other, but also with supporting technologies and capabilities in other biomedical fields. By embracing cross-modality and cross-disciplinary interactions with these parallel fields, optical elastography can greatly increase its potential to drive new discoveries in the biomedical sciences as well as the development of novel biomechanics-based clinical diagnostics and therapeutics.
Collapse
Affiliation(s)
- Nichaluk Leartprapun
- Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York 14853, USA
- Present affiliation: Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
| | - Steven G. Adie
- Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, New York 14853, USA
| |
Collapse
|
19
|
Li Y, Gao Q, Chen N, Zhang Y, Wang J, Li C, He X, Jiao Y, Zhang Z. Clinical studies of magnetic resonance elastography from 1995 to 2021: Scientometric and visualization analysis based on CiteSpace. Quant Imaging Med Surg 2022; 12:5080-5100. [PMID: 36330182 PMCID: PMC9622435 DOI: 10.21037/qims-22-207] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2022] [Accepted: 08/11/2022] [Indexed: 02/05/2023]
Abstract
BACKGROUND To assess the knowledge framework around magnetic resonance elastography (MRE) and to explore MRE research hotspots and emerging trends. METHODS The Science Citation Index Expanded of the Web of Science Core Collection was searched on 22 October 2021 for MRE-related studies published between 1995 and 2021. Excel 2016 and CiteSpace V (version 5.8.R3) were used to analyze the downloaded data. RESULTS In all, 1,236 articles published by 726 authors from 540 institutions in 40 countries were included in this study. The top 10 authors published 57.6% of all included articles. The 3 most productive countries were the USA (n=631), Germany (n=202), and France (n=134), and the 3 most productive institutions were the Mayo Clinic (n=240), Charité (n=131), and the University of Illinois (n=56). The USA and the Mayo Clinic had the highest betweenness centrality among countries and institutions, respectively, and played an important role in the field of MRE. In this study, the 24,347 distinct references were clustered into 48 categories via reasonable clustering using specific keywords, forming the knowledge framework. Among the 294 co-occurring keywords, "hepatic fibrosis", "stiffness", "skeletal muscle", "acoustic strain wave", "in vivo", and "non-invasive assessment" were research hotspots. "Diagnostic performance", "diagnostic accuracy", "hepatic steatosis", "chronic hepatitis B", "radiation force impulse", "children", and "echo" were frontier topics. CONCLUSIONS Scientometric and visualized analysis of MRE can provide information regarding the knowledge framework, research hotspots, frontier areas, and emerging trends in this field.
Collapse
Affiliation(s)
- Youwei Li
- Department of Radiology, Beijing Rehabilitation Hospital, Capital Medical University, Beijing, China
| | - Qiang Gao
- Department of Gastroenterology and Hepatology, Beijing Rehabilitation Hospital, Capital Medical University, Beijing, China
| | - Na Chen
- Department of Otorhinolaryngology, Beijing Rehabilitation Hospital, Capital Medical University, Beijing, China
| | - Yuanfang Zhang
- Department of Radiology, Beijing Rehabilitation Hospital, Capital Medical University, Beijing, China
| | - Juan Wang
- Department of Radiology, Beijing Rehabilitation Hospital, Capital Medical University, Beijing, China
| | - Chang Li
- Department of Radiology, Beijing Rehabilitation Hospital, Capital Medical University, Beijing, China
| | - Xuan He
- Department of Radiology, Beijing Rehabilitation Hospital, Capital Medical University, Beijing, China
| | - Yang Jiao
- Department of Rehabilitation Psychology, Beijing Rehabilitation Hospital, Capital Medical University, Beijing, China
| | - Zongming Zhang
- Department of General Surgery, Beijing Electric Power Hospital, State Grid Corporation of China, Capital Medical University, Beijing, China
| |
Collapse
|
20
|
Hermes D, Wu H, Kerr AB, Wandell BA. Measuring brain beats: Cardiac-aligned fast functional magnetic resonance imaging signals. Hum Brain Mapp 2022; 44:280-294. [PMID: 36308417 PMCID: PMC9783469 DOI: 10.1002/hbm.26128] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 09/17/2022] [Accepted: 09/26/2022] [Indexed: 02/05/2023] Open
Abstract
Blood and cerebrospinal fluid (CSF) pulse and flow throughout the brain, driven by the cardiac cycle. These fluid dynamics, which are essential to healthy brain function, are characterized by several noninvasive magnetic resonance imaging (MRI) methods. Recent developments in fast MRI, specifically simultaneous multislice acquisition methods, provide a new opportunity to rapidly and broadly assess cardiac-driven flow, including CSF spaces, surface vessels and parenchymal vessels. We use these techniques to assess blood and CSF flow dynamics in brief (3.5 min) scans on a conventional 3 T MRI scanner in five subjects. Cardiac pulses are measured with a photoplethysmography (PPG) on the index finger, along with functional MRI (fMRI) signals in the brain. We, retrospectively, align the fMRI signals to the heartbeat. Highly reliable cardiac-gated fMRI temporal signals are observed in CSF and blood on the timescale of one heartbeat (test-retest reliability within subjects R2 > 50%). In blood vessels, a local minimum is observed following systole. In CSF spaces, the ventricles and subarachnoid spaces have a local maximum following systole instead. Slower resting-state scans with slice timing, retrospectively, aligned to the cardiac pulse, reveal similar cardiac-gated responses. The cardiac-gated measurements estimate the amplitude and phase of fMRI pulsations in the CSF relative to those in the arteries, an estimate of the local intracranial impedance. Cardiac aligned fMRI signals can provide new insights about fluid dynamics or diagnostics for diseases where these dynamics are important.
Collapse
Affiliation(s)
- Dora Hermes
- Department of Physiology and Biomedical EngineeringMayo ClinicRochesterMinnesotaUSA,Department of PsychologyStanford UniversityStanfordCaliforniaUSA
| | - Hua Wu
- Center for Cognitive and Neurobiological ImagingStanford UniversityStanfordCaliforniaUSA
| | - Adam B. Kerr
- Center for Cognitive and Neurobiological ImagingStanford UniversityStanfordCaliforniaUSA,Department of Electrical EngineeringStanford UniversityStanfordCaliforniaUSA
| | - Brian A. Wandell
- Department of PsychologyStanford UniversityStanfordCaliforniaUSA
| |
Collapse
|
21
|
Hirano R, Rogalla P, Farrell C, Hoppel B, Fujisawa Y, Ohyu S, Hattori C, Sakaguchi T. Development of a classification method for mild liver fibrosis using non-contrast CT image. Int J Comput Assist Radiol Surg 2022; 17:2041-2049. [PMID: 35930131 DOI: 10.1007/s11548-022-02724-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Accepted: 07/19/2022] [Indexed: 11/24/2022]
Abstract
PURPOSE Detection of early-stage liver fibrosis has direct clinical implications on patient management and treatment. The aim of this paper is to develop a non-invasive, cost-effective method for classifying liver disease between "non-fibrosis" (F0) and "fibrosis" (F1-F4), and to evaluate the classification performance quantitatively. METHODS Image data from 75 patients who underwent a simultaneous liver biopsy and non-contrast CT examination were used for this study. Non-contrast CT image texture features such as wavelet-based features, standard deviation of variance filter, and mean CT number were calculated in volumes of interest (VOIs) positioned within the liver parenchyma. In addition, a combined feature was calculated using logistic regression with L2-norm regularization to further improve fibrosis detection. Based on the final pathology from the liver biopsy, the patients were labelled either as "non-fibrosis" or "fibrosis". Receiver-operating characteristic (ROC) curve, area under the ROC curve (AUROC), specificity, sensitivity, and accuracy were determined for the algorithm to differentiate between "non-fibrosis" and "fibrosis". RESULTS The combined feature showed the highest classification performance with an AUROC of 0.86, compared to the wavelet-based feature (AUROC, 0.76), the standard deviation of variance filter (AUROC, 0.65), and mean CT number (AUROC, 0.84). The combined feature's specificity, sensitivity, and accuracy were 0.66, 0.88, and 0.76, respectively, showing the most promising results. CONCLUSION A new non-invasive and cost-effective method was developed to classify liver diseases between "non-fibrosis" (F0) and "fibrosis" (F1-F4). The proposed method makes it possible to detect liver fibrosis in asymptomatic patients using non-contrast CT images for better patient management and treatment.
Collapse
Affiliation(s)
- Ryo Hirano
- Research and Development Center, Canon Medical Systems Corporation, Otawara, Japan.
| | - Patrik Rogalla
- Joint Department of Medical Imaging, University of Toronto, Toronto, Canada
| | | | | | - Yasuko Fujisawa
- Research and Development Center, Canon Medical Systems Corporation, Otawara, Japan
| | - Shigeharu Ohyu
- Research and Development Center, Canon Medical Systems Corporation, Otawara, Japan
| | - Chihiro Hattori
- Research and Development Center, Canon Medical Systems Corporation, Otawara, Japan
| | - Takuya Sakaguchi
- Research and Development Center, Canon Medical Systems Corporation, Otawara, Japan
| |
Collapse
|
22
|
Patel BK, Pepin K, Brandt KR, Mazza GL, Pockaj BA, Chen J, Zhou Y, Northfelt DW, Anderson K, Kling JM, Vachon CM, Swanson KR, Nikkhah M, Ehman R. Association of breast cancer risk, density, and stiffness: global tissue stiffness on breast MR elastography (MRE). Breast Cancer Res Treat 2022; 194:79-89. [PMID: 35501423 PMCID: PMC9538705 DOI: 10.1007/s10549-022-06607-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Accepted: 04/05/2022] [Indexed: 11/25/2022]
Abstract
PURPOSE Quantify in vivo biomechanical tissue properties in various breast densities and in average risk and high-risk women using Magnetic Resonance Imaging (MRI)/MRE and examine the association between breast biomechanical properties and cancer risk based on patient demographics and clinical data. METHODS Patients with average risk or high-risk of breast cancer underwent 3.0 T breast MR imaging and elastography. Breast parenchymal enhancement (BPE), density (from most recent mammogram), stiffness, elasticity, and viscosity were recorded. Within each breast density group (non-dense versus dense), stiffness, elasticity, and viscosity were compared across risk groups (average versus high). Separately for stiffness, elasticity, and viscosity, a multivariable logistic regression model was used to evaluate whether the MRE parameter predicted risk status after controlling for clinical factors. RESULTS 50 average risk and 86 high-risk patients were included. Risk groups were similar in age, density, and menopausal status. Among patients with dense breasts, mean stiffness, elasticity, and viscosity were significantly higher in high-risk patients (N = 55) compared to average risk patients (N = 34; all p < 0.001). Stiffness remained a significant predictor of risk status (OR = 4.26, 95% CI [1.96, 9.25]) even after controlling for breast density, BPE, age, and menopausal status. Similar results were seen for elasticity and viscosity. CONCLUSION A structurally based, quantitative biomarker of tissue stiffness obtained from MRE is associated with differences in breast cancer risk in dense breasts. Tissue stiffness could provide a novel prognostic marker to help identify high-risk women with dense breasts who would benefit from increased surveillance and/or risk reduction measures.
Collapse
Affiliation(s)
- Bhavika K Patel
- Diagnostic Radiology, Mayo Clinic, 5777 E. Mayo Blvd., Phoenix, AZ, 85054, USA.
| | - Kay Pepin
- Diagnostic Radiology, Mayo Clinic, Rochester, MN, USA
| | | | - Gina L Mazza
- Department of Biostatistics, Mayo Clinic, Phoenix, AZ, USA
| | | | - Jun Chen
- Diagnostic Radiology, Mayo Clinic, Rochester, MN, USA
| | - Yuxiang Zhou
- Diagnostic Radiology, Mayo Clinic, 5777 E. Mayo Blvd., Phoenix, AZ, 85054, USA
| | | | | | - Juliana M Kling
- Department of Internal Medicine, Mayo Clinic, Phoenix, AZ, USA
| | | | | | - Mehdi Nikkhah
- School of Biological and Health Systems Engineering, Arizona State University, Phoenix, AZ, USA
- Biodesign Virginia G. Piper Center for Personalized Diagnostics, Arizona State University, Tempe, AZ, USA
| | - Richard Ehman
- Diagnostic Radiology, Mayo Clinic, Rochester, MN, USA
| |
Collapse
|
23
|
Guo T, He C, Venado A, Zhou Y. Extracellular Matrix Stiffness in Lung Health and Disease. Compr Physiol 2022; 12:3523-3558. [PMID: 35766837 PMCID: PMC10088466 DOI: 10.1002/cphy.c210032] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The extracellular matrix (ECM) provides structural support and imparts a wide variety of environmental cues to cells. In the past decade, a growing body of work revealed that the mechanical properties of the ECM, commonly known as matrix stiffness, regulate the fundamental cellular processes of the lung. There is growing appreciation that mechanical interplays between cells and associated ECM are essential to maintain lung homeostasis. Dysregulation of ECM-derived mechanical signaling via altered mechanosensing and mechanotransduction pathways is associated with many common lung diseases. Matrix stiffening is a hallmark of lung fibrosis. The stiffened ECM is not merely a sequelae of lung fibrosis but can actively drive the progression of fibrotic lung disease. In this article, we provide a comprehensive view on the role of matrix stiffness in lung health and disease. We begin by summarizing the effects of matrix stiffness on the function and behavior of various lung cell types and on regulation of biomolecule activity and key physiological processes, including host immune response and cellular metabolism. We discuss the potential mechanisms by which cells probe matrix stiffness and convert mechanical signals to regulate gene expression. We highlight the factors that govern matrix stiffness and outline the role of matrix stiffness in lung development and the pathogenesis of pulmonary fibrosis, pulmonary hypertension, asthma, chronic obstructive pulmonary disease (COPD), and lung cancer. We envision targeting of deleterious matrix mechanical cues for treatment of fibrotic lung disease. Advances in technologies for matrix stiffness measurements and design of stiffness-tunable matrix substrates are also explored. © 2022 American Physiological Society. Compr Physiol 12:3523-3558, 2022.
Collapse
Affiliation(s)
- Ting Guo
- Division of Pulmonary, Allergy and Critical Care Medicine, Department of Medicine, University of Alabama at Birmingham, Alabama, USA.,Department of Respiratory Medicine, the Second Xiangya Hospital, Central-South University, Changsha, Hunan, China
| | - Chao He
- Division of Pulmonary, Allergy and Critical Care Medicine, Department of Medicine, University of Alabama at Birmingham, Alabama, USA
| | - Aida Venado
- Pulmonary, Critical Care, Allergy and Sleep Medicine, Department of Medicine, University of California San Francisco, San Francisco, California, USA
| | - Yong Zhou
- Division of Pulmonary, Allergy and Critical Care Medicine, Department of Medicine, University of Alabama at Birmingham, Alabama, USA
| |
Collapse
|
24
|
Du Q, Bel-Brunon A, Lambert SA, Hamila N. Numerical simulation of wave propagation through interfaces using the extended finite element method for magnetic resonance elastography. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 151:3481. [PMID: 35649898 PMCID: PMC9381142 DOI: 10.1121/10.0011392] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/03/2023]
Abstract
Magnetic resonance elastography (MRE) is an elasticity imaging technique for quantitatively assessing the stiffness of human tissues. In MRE, finite element method (FEM) is widely used for modeling wave propagation and stiffness reconstruction. However, in front of inclusions with complex interfaces, FEM can become burdensome in terms of the model partition and computationally expensive. In this work, we implement a formulation of FEM, known as the eXtended finite element method (XFEM), which is a method used for modeling discontinuity like crack and heterogeneity. Using a level-set method, it makes the interface independent of the mesh, thus relieving the meshing efforts. We investigate this method in two studies: wave propagation across an oblique linear interface and stiffness reconstruction of a random-shape inclusion. In the first study, numerical results by XFEM and FEM models revealing the wave conversion rules at linear interface are presented and successfully compared to the theoretical predictions. The second study, investigated in a pseudo-practical application, demonstrates further the applicability of XFEM in MRE and the convenience, accuracy, and speed of XFEM with respect to FEM. XFEM can be regarded as a promising alternative to FEM for inclusion modeling in MRE.
Collapse
Affiliation(s)
- Quanshangze Du
- Univ Lyon, INSA Lyon, CNRS, LaMCoS, UMR5259, 69621 Villeurbanne, France
| | - Aline Bel-Brunon
- Univ Lyon, INSA Lyon, CNRS, LaMCoS, UMR5259, 69621 Villeurbanne, France
- Electronic mail:
| | - Simon Auguste Lambert
- Université de Lyon, INSA Lyon, Université Claude Bernard Lyon 1, Ecole Centrale de Lyon, CNRS, Ampère UMR5005, Villeurbanne, France
| | | |
Collapse
|
25
|
Zhang J, Fan F, Zhu L, Wang C, Chen X, Xinxiao G, Zhu J. Elasticity measurements of ocular anterior and posterior segments using optical coherence elastography. OPTICS EXPRESS 2022; 30:14311-14318. [PMID: 35473177 DOI: 10.1364/oe.456065] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Accepted: 04/01/2022] [Indexed: 06/14/2023]
Abstract
The changes of biomechanical properties, especially the elasticity of the ocular tissues, are closely related to some ophthalmic diseases. Currently, the ophthalmic optical coherence elastography (OCE) systems are dedicated either to the anterior segment or to the retina. The elasticity measurements of the whole eye remain challenging. Here we demonstrated an acoustic radiation force optical coherence elastography (ARF-OCE) method to quantify the elasticity of the cornea and the retina. The experiment results show that the Young's moduli of the cornea and the retina were 16.66 ± 6.51 kPa and 207.96 ± 4.75 kPa, respectively. Our method can measure the elasticity of the anterior segment and the posterior segment, and provides a powerful tool to enhance ophthalmology research.
Collapse
|
26
|
Subhan MA, Muzibur Rahman M. Recent Development in Metallic Nanoparticles for Breast Cancer Therapy and Diagnosis. CHEM REC 2022; 22:e202100331. [PMID: 35146897 DOI: 10.1002/tcr.202100331] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 01/30/2022] [Indexed: 12/25/2022]
Abstract
Metal-based nanoparticles are very promising for their applications in cancer diagnosis, drug delivery and therapy. Breast cancer is the major reason of death in woman especially in developed countries including EU and USA. Due to the heterogeneity of cancer cells, nanoparticles are effective as therapeutics and diagnostics. Anti-cancer therapy of breast tumors is challenging because of highly metastatic progression of the disease to brain, bone, lung, and liver. Magnetic nanoparticles are crucial for metastatic breast cancer detection and protection. This review comprehensively discusses the application of nanomaterials as breast cancer therapy, therapeutics, and diagnostics.
Collapse
Affiliation(s)
- Md Abdus Subhan
- Department of Chemistry, School of Physical Sciences, Shah Jalal University of Science and Technology, 3114, Sylhet, Bangladesh
| | - Mohammed Muzibur Rahman
- Center of Excellence for Advanced Materials Research (CEAMR) & Department of Chemistry, Faculty of Science, King Abdulaziz University, P.O. Box 80203, 21589, Jeddah, Saudi Arabia
| |
Collapse
|
27
|
Zvietcovich F, Larin KV. Wave-based optical coherence elastography: The 10-year perspective. PROGRESS IN BIOMEDICAL ENGINEERING (BRISTOL, ENGLAND) 2022; 4:012007. [PMID: 35187403 PMCID: PMC8856668 DOI: 10.1088/2516-1091/ac4512] [Citation(s) in RCA: 27] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
After 10 years of progress and innovation, optical coherence elastography (OCE) based on the propagation of mechanical waves has become one of the major and the most studied OCE branches, producing a fundamental impact in the quantitative and nondestructive biomechanical characterization of tissues. Preceding previous progress made in ultrasound and magnetic resonance elastography; wave-based OCE has pushed to the limit the advance of three major pillars: (1) implementation of novel wave excitation methods in tissues, (2) understanding new types of mechanical waves in complex boundary conditions by proposing advance analytical and numerical models, and (3) the development of novel estimators capable of retrieving quantitative 2D/3D biomechanical information of tissues. This remarkable progress promoted a major advance in answering basic science questions and the improvement of medical disease diagnosis and treatment monitoring in several types of tissues leading, ultimately, to the first attempts of clinical trials and translational research aiming to have wave-based OCE working in clinical environments. This paper summarizes the fundamental up-to-date principles and categories of wave-based OCE, revises the timeline and the state-of-the-art techniques and applications lying in those categories, and concludes with a discussion on the current challenges and future directions, including clinical translation research.
Collapse
Affiliation(s)
- Fernando Zvietcovich
- University of Houston, Biomedical Engineering, Houston, TX, United States, 77204
| | - Kirill V. Larin
- University of Houston, Biomedical Engineering, Houston, TX, United States, 77204,
| |
Collapse
|
28
|
Han X, Zhang Y, Zhu Y, Zhao Y, Yang H, Liu G, Ai S, Wang Y, Xie C, Shi J, Zhang T, Huang G, He X. Quantification of biomechanical properties of human corneal scar using acoustic radiation force optical coherence elastography. Exp Biol Med (Maywood) 2021; 247:462-469. [PMID: 34861122 PMCID: PMC8943333 DOI: 10.1177/15353702211061881] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
Biomechanical properties of corneal scar are strongly correlated with many corneal diseases and some types of corneal surgery, however, there is no elasticity information available about corneal scar to date. Here, we proposed an acoustic radiation force optical coherence elastography system to evaluate corneal scar elasticity. Elasticity quantification was first conducted on ex vivo rabbit corneas, and the results validate the efficacy of our system. Then, experiments were performed on an ex vivo human scarred cornea, where the structural features, the elastic wave propagations, and the corresponding Young's modulus of both the scarred region and the normal region were achieved and based on this, 2D spatial distribution of Young's modulus of the scarred cornea was depicted. Up to our knowledge, we realized the first elasticity quantification of corneal scar, which may provide a potent tool to promote clinical research on the disorders and surgery of the cornea.
Collapse
Affiliation(s)
- Xiao Han
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang 330063, P. R. China
| | - Yubao Zhang
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang 330063, P. R. China
| | - Yirui Zhu
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang 330063, P. R. China
| | - Yanzhi Zhao
- The Third Affiliated Hospital of Nanchang University, Nanchang 330008, P. R. China
| | - Hongwei Yang
- The Third Affiliated Hospital of Nanchang University, Nanchang 330008, P. R. China
| | - Guo Liu
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang 330063, P. R. China
| | - Sizhu Ai
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang 330063, P. R. China
| | - Yidi Wang
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang 330063, P. R. China
| | - Chengfeng Xie
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang 330063, P. R. China
| | - Jiulin Shi
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang 330063, P. R. China
| | - Tianyu Zhang
- Key Laboratory of Geophysical Exploration Equipment, Ministry of Education, College of Instrumentation & Electrical Engineering, 12510Jilin University, Changchun 130012, P. R. China
| | - Guofu Huang
- The Third Affiliated Hospital of Nanchang University, Nanchang 330008, P. R. China
| | - Xingdao He
- Key Laboratory of Opto-Electronic Information Science and Technology of Jiangxi Province and Jiangxi Engineering Laboratory for Optoelectronics Testing Technology, Nanchang Hangkong University, Nanchang 330063, P. R. China
| |
Collapse
|
29
|
Tavakoli J, Geargeflia S, Tipper JL, Diwan AD. Magnetic resonance elastography: A non-invasive biomarker for low back pain studies. BIOMEDICAL ENGINEERING ADVANCES 2021. [DOI: 10.1016/j.bea.2021.100014] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
|
30
|
Kim J, Ryu JA, Lee J. Quantification of the Elastic Property of Normal Thigh Muscles Using MR Elastography: Our Initial Experience. TAEHAN YONGSANG UIHAKHOE CHI 2021; 82:1556-1564. [PMID: 36238872 PMCID: PMC9431979 DOI: 10.3348/jksr.2020.0133] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Revised: 12/20/2020] [Accepted: 04/02/2021] [Indexed: 11/19/2022]
Abstract
Purpose This study aimed to apply MR elastography (MRE) to achieve in vivo evaluation of the elastic properties of thigh muscles and validate the feasibility of quantifying the elasticity of normal thigh muscles using MRE. Materials and Methods This prospective study included 10 volunteer subjects [mean age, 32.5 years, (range, 23-45 years)] who reported normal activities of daily living and underwent both T2-weighted axial images and MRE of thigh muscles on the same day. A sequence with a motion-encoding gradient was used in the MRE to map the propagating shear waves in the muscle. Elastic properties were quantified as the shear modulus of the following four thigh muscles at rest; the vastus medialis, vastus lateralis, adductor magnus, and biceps femoris. Results The mean shear modulus was 0.98 ± 0.32 kPa and 1.00 ± 0.33 kPa for the vastus medialis, 1.10 ± 0.46 kPa and 1.07 ± 0.43 kPa for the vastus lateralis, 0.91 ± 0.41 kPa and 0.93 ± 0.47 kPa for the adductor magnus, and 0.99 ± 0.37 kPa and 0.94 ± 0.32 kPa for the biceps femoris, with reader 1 and 2, respectively. No significant difference was observed in the shear modulus based on sex (p < 0.05). Aging consistently showed a statistically significant negative correlation (p < 0.05) with the shear modulus of the thigh muscles, except for the vastus medialis (p = 0.194 for reader 1 and p = 0.355 for reader 2). Conclusion MRE is a quantitative technique used to measure the elastic properties of individual muscles with excellent inter-observer agreement. Age was consistently significantly negatively correlated with the shear stiffness of muscles, except for the vastus medialis.
Collapse
|
31
|
Ballard DH, Ludwig DR, Fraum TJ, Salter A, Narra VR, Shetty AS. Quality Control of Magnetic Resonance Elastography Using Percent Measurable Liver Volume Estimation. J Magn Reson Imaging 2021; 55:1890-1899. [PMID: 34704644 DOI: 10.1002/jmri.27976] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 10/17/2021] [Accepted: 10/19/2021] [Indexed: 12/28/2022] Open
Abstract
BACKGROUND Although studies have described factors associated with failed magnetic resonance elastography (MRE), little is known about what factors influence usable elastography data. PURPOSE To identify factors that have a negative impact on percent measurable liver volume (pMLV), defined as the proportion of usable liver elastography data relative to the volume of imaged liver in patients undergoing MRE. STUDY TYPE Retrospective. SUBJECTS A total of 264 patients (n = 132 males, n = 132 females; mean age = 57 years) with suspected or known chronic liver disease underwent MRE paired with a liver protocol MRI. FIELD STRENGTH/SEQUENCE MRE was performed on a single 1.5 T scanner using a two-dimensional gradient-recalled echo phase-contrast sequence with a passive acoustic driver overlying the right hemiliver. ASSESSMENT Stiffness maps (usable data at 95% confidence) and liver contours on magnitude images of the MRE acquisition were manually traced and used to assess mean stiffness and pMLV. Hepatic fat fraction and R2 * values were also calculated. The distance from the acoustic wave generator on the skin surface to the liver edge was measured. Two radiologists performed the MR analyses with 50 overlapping cases for inter-reader analysis. STATISTICAL TESTS Linear regression was performed to identify factors significantly associated with pMLV. Intraclass correlation was performed for inter-reader reliability. RESULTS pMLV was 31% ± 20% (range 0%-86%). Complete MRE failure (i.e. pMLV = 0%) occurred in 10 patients (4%). Multivariate linear regression identified higher hepatic fat fraction, R2 *, BMI, and driver-to-liver surface distance; male sex; and lower mean liver stiffness was significantly independently associated with lower pMLV. Intraclass correlation for pMLV was 0.96, suggestive of excellent reliability. DATA CONCLUSION Higher fat fraction, R2 *, BMI, driver-to-liver surface distance, male sex, and lower mean liver stiffness were associated with lower pMLV. Optimization of image acquisition parameters and driver placement may improve MRE quality, and pMLV likely serves as a diagnostic utility quality control metric. LEVEL OF EVIDENCE 3 TECHNICAL EFFICACY STAGE: 2.
Collapse
Affiliation(s)
- David H Ballard
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri, USA
| | - Daniel R Ludwig
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri, USA
| | - Tyler J Fraum
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri, USA
| | - Amber Salter
- Division of Biostatistics, Washington University School of Medicine, St. Louis, Missouri, USA
| | - Vamsi R Narra
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri, USA
| | - Anup S Shetty
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, St. Louis, Missouri, USA
| |
Collapse
|
32
|
A novel technique for automating stiffness measurement and emphasizing the main wave: Coherent-wave auto-selection (CHASE). Magn Reson Imaging 2021; 85:133-140. [PMID: 34687851 DOI: 10.1016/j.mri.2021.10.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2021] [Revised: 05/17/2021] [Accepted: 10/17/2021] [Indexed: 11/20/2022]
Abstract
This study aims to develop and assess a new automated processing technique in MR elastography (MRE), namely coherent-wave auto-selection (CHASE). CHASE enables automatic selection of the region of interest (ROI) for stiffness measurement by extraction of the coherent wave region (CHASE ROI), and it improves the reconstruction of stiffness by a directional filter oriented along the main wave in each pixel (CHASE filtering). In this study, MRE of a phantom and of the liver of four healthy volunteers was performed. To investigate the potential of CHASE, this study assessed the CHASE according to three indices through the phantom study: 1) agreement on the ROI settings between CHASE and expert observers, 2) noise dependency, and 3) effect of the CHASE on stiffness variability within the CHASE ROI. The agreements on the ROI settings were analyzed by Cohen's kappa coefficient (κ). The noise dependency was analyzed by the mean absolute percentage errors (MAPEs) within the ROI between low (20%-80% amplitudes) and high vibration amplitudes (100% amplitude). The stiffness variability was assessed by standard deviation (SD) within the ROI. In the volunteer study, agreements on the ROI settings (or stiffness value) and stiffness variability within the CHASE ROI were assessed using κ-value (or intraclass correlation coefficient: ICC) and coefficient of variation, respectively. The results showed close agreement on the ROI settings and stiffness (κ-value: greater than 0.61 in both the phantom and volunteer studies, ICC: 0.97 in the volunteer study). The MAPEs within the CHASE ROI were much smaller than those in the whole region of the phantom (CHASE ROI vs. the whole region at 20% amplitude: 10.3% vs. 50.8%). Moreover, in both the phantom and volunteer studies, the stiffness variation within the CHASE ROI was smaller in the elastogram processed with CHASE filtering than in the unprocessed one. Our results demonstrated that the CHASE has high robustness against noise and the potential to provide ROI settings for stiffness measurement comparable to expert observers, as well as improve the reconstruction of stiffness.
Collapse
|
33
|
Liu W, Rong D, Zhu J, Xiao Y, Zhang L, Deng Y, Chen J, Yin M, Venkatesh SK, Ehman RL, Wang J. Diagnostic accuracy of 3D magnetic resonance elastography for assessing histologic grade of hepatocellular carcinoma: comparison of three methods for positioning region of interest. Abdom Radiol (NY) 2021; 46:4601-4609. [PMID: 34085091 DOI: 10.1007/s00261-021-03150-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 05/23/2021] [Accepted: 05/24/2021] [Indexed: 12/11/2022]
Abstract
PURPOSE To assess the influence of region of interest (ROI) placement on the predictive value of 3D MRE in differentiating the histologic grade of HCC. METHODS 85 patients with pathologically confirmed HCCs were analyzed using 3D MRE imaging, two radiologists measured the tumor stiffness with three different ROI positioning methods. Intraclass correlation coefficient (ICC) was expressed in terms of inter- and intra-observer agreements. Kruskal-Wallis rank test or one-way ANOVA was used to compare the difference in MRE stiffness across the three-ROI positioning methods. Receiver operating characteristic curve analysis (ROC) was performed, and the area under curve (AUC) was measured to evaluate the diagnostic performance. RESULTS There were 64 (75%) well-or-moderately differentiated HCCs and 21(25%) poorly differentiated HCCs included finally. Almost excellent inter- and intra-observer agreements (all ICC > 0.82) were observed for all three-ROI methods, the volumetric method has the highest values (inter-observer ICC 0.967, intra-observer ICC 0.919, 0.926, respectively). The mean stiffnesses of poorly differentiated HCC obtained by two readers were significantly higher than well-or-moderately differentiated HCC with volumetric method (7.07 ± 1.57 Kpa, 5.00 ± 1.49 Kpa, and 6.85 ± 1.49 Kpa, 4.94 ± 1.48 Kpa, respectively) and three-ROI method (6.14 ± 1.71 Kpa, 4.91 ± 1.56 Kpa and 5.94 ± 1.61 Kpa, 4.84 ± 1.54 Kpa, respectively) but not on single-ROI method (p > 0.005), for the diagnostic performance, the highest area under the curve (AUC) with a value of 0.837, 0.812 by using the volumetric method, followed by the three-ROI method (0.713, 0.754) and single-ROI method. CONCLUSION Different ROI positioning methods significantly affect HCC tumor stiffness measurements. The whole tumor volumetric analysis is superior to ROI-based methods for predicting the grade of HCC.
Collapse
Affiliation(s)
- Weimin Liu
- Department of Radiology, The Third Affiliated Hospital, Sun Yat-Sen University (SYSU), Tianhe Road, No 600, Guangzhou, Guangdong, 510630, People's Republic Of China
| | - Dailin Rong
- Department of Radiology, The Third Affiliated Hospital, Sun Yat-Sen University (SYSU), Tianhe Road, No 600, Guangzhou, Guangdong, 510630, People's Republic Of China
| | - Jie Zhu
- Department of Radiology, The Third Affiliated Hospital, Sun Yat-Sen University (SYSU), Tianhe Road, No 600, Guangzhou, Guangdong, 510630, People's Republic Of China
| | - Yuanqiang Xiao
- Department of Radiology, The Third Affiliated Hospital, Sun Yat-Sen University (SYSU), Tianhe Road, No 600, Guangzhou, Guangdong, 510630, People's Republic Of China
| | - Linqi Zhang
- Department of Radiology, The Third Affiliated Hospital, Sun Yat-Sen University (SYSU), Tianhe Road, No 600, Guangzhou, Guangdong, 510630, People's Republic Of China
| | - Ying Deng
- Department of Radiology, The Third Affiliated Hospital, Sun Yat-Sen University (SYSU), Tianhe Road, No 600, Guangzhou, Guangdong, 510630, People's Republic Of China
| | - Jun Chen
- Department of Radiology, Mayo Clinic College of Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Meng Yin
- Department of Radiology, Mayo Clinic College of Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Sudhakar K Venkatesh
- Department of Radiology, Mayo Clinic College of Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Richard L Ehman
- Department of Radiology, Mayo Clinic College of Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA
| | - Jin Wang
- Department of Radiology, The Third Affiliated Hospital, Sun Yat-Sen University (SYSU), Tianhe Road, No 600, Guangzhou, Guangdong, 510630, People's Republic Of China.
| |
Collapse
|
34
|
Reye G, Huang X, Haupt LM, Murphy RJ, Northey JJ, Thompson EW, Momot KI, Hugo HJ. Mechanical Pressure Driving Proteoglycan Expression in Mammographic Density: a Self-perpetuating Cycle? J Mammary Gland Biol Neoplasia 2021; 26:277-296. [PMID: 34449016 PMCID: PMC8566410 DOI: 10.1007/s10911-021-09494-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2021] [Accepted: 07/05/2021] [Indexed: 12/23/2022] Open
Abstract
Regions of high mammographic density (MD) in the breast are characterised by a proteoglycan (PG)-rich fibrous stroma, where PGs mediate aligned collagen fibrils to control tissue stiffness and hence the response to mechanical forces. Literature is accumulating to support the notion that mechanical stiffness may drive PG synthesis in the breast contributing to MD. We review emerging patterns in MD and other biological settings, of a positive feedback cycle of force promoting PG synthesis, such as in articular cartilage, due to increased pressure on weight bearing joints. Furthermore, we present evidence to suggest a pro-tumorigenic effect of increased mechanical force on epithelial cells in contexts where PG-mediated, aligned collagen fibrous tissue abounds, with implications for breast cancer development attributable to high MD. Finally, we summarise means through which this positive feedback mechanism of PG synthesis may be intercepted to reduce mechanical force within tissues and thus reduce disease burden.
Collapse
Affiliation(s)
- Gina Reye
- School of Biomedical Sciences, Gardens Point, Queensland University of Technology (QUT), Kelvin Grove, QLD, 4059, Australia
- Translational Research Institute, Woolloongabba, QLD, Australia
| | - Xuan Huang
- School of Biomedical Sciences, Gardens Point, Queensland University of Technology (QUT), Kelvin Grove, QLD, 4059, Australia
- Translational Research Institute, Woolloongabba, QLD, Australia
| | - Larisa M Haupt
- Centre for Genomics and Personalised Health, Genomics Research Centre, School of Biomedical Sciences, Faculty of Health, Institute of Health and Biomedical Innovation, Queensland University of Technology (QUT), 60 Musk Ave, Kelvin Grove, QLD, 4059, Australia
| | - Ryan J Murphy
- School of Mathematical Sciences, Gardens Point, Queensland University of Technology (QUT), Kelvin Grove, QLD, Australia
| | - Jason J Northey
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, 19104, USA
| | - Erik W Thompson
- School of Biomedical Sciences, Gardens Point, Queensland University of Technology (QUT), Kelvin Grove, QLD, 4059, Australia
- Translational Research Institute, Woolloongabba, QLD, Australia
| | - Konstantin I Momot
- School of Chemistry and Physics, Queensland University of Technology (QUT), Brisbane, QLD, Australia
| | - Honor J Hugo
- School of Biomedical Sciences, Gardens Point, Queensland University of Technology (QUT), Kelvin Grove, QLD, 4059, Australia.
- Translational Research Institute, Woolloongabba, QLD, Australia.
| |
Collapse
|
35
|
Comparison of the diagnostic performance of 2D and 3D MR elastography in staging liver fibrosis. Eur Radiol 2021; 31:9468-9478. [PMID: 34023968 DOI: 10.1007/s00330-021-08053-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Revised: 04/16/2021] [Accepted: 05/06/2021] [Indexed: 12/12/2022]
Abstract
OBJECTIVES To compare the diagnostic performance and image quality of state-of-the-art 2D MR elastography (MRE) and 3D MRE in the basic application of liver fibrosis staging. METHODS This retrospective study assessed data from 293 patients who underwent 2D and 3D MRE examinations. MRE image quality was assessed with a qualitative 2-point grading system by evaluating artifacts. Two experienced analysts independently measured mean liver stiffness values. The interobserver agreement of liver stiffness measurement was assessed by the intraclass correlation coefficient (ICC). The area under the receiver operating characteristic curve (AUC) was used to assess the diagnostic performance of 2D and 3D MRE and blood-based markers for fibrosis staging using the pathology-proven liver fibrosis stage as the gold standard. RESULTS The image quality provided by 3D MRE was graded as significantly higher than that obtained with the 2D MRE method (p < 0.01). Interobserver agreement in liver stiffness measurements was higher for 3D MRE (ICC: 3D 0.979 vs 2D 0.955). The AUC values for discriminating ≥ F1, ≥ F2, ≥ F3, and F4 fibrosis for 3D MRE (0.89, 0.92, 0.95, and 0.93) were similar to those for 2D MRE (0.89, 0.91, 0.94, and 0.92). Both the 2D and 3D MRE methods provided superior accuracy to the blood-based biomarkers, including APRI, FIB-4, and Forns index, especially for ≥ F2, ≥ F3, and F4 fibrosis stages (all p < 0.01). CONCLUSIONS While 3D MRE offers certain advantages and opportunities for new applications of MRE, current widely deployed 2D MRE technology has comparable performance in the basic application of detecting and staging liver fibrosis. KEY POINTS • 2D MRE and 3D MRE have comparable diagnostic performance in detecting and staging liver fibrosis. • 3D MRE has superior image quality and interobserver agreement compared to 2D MRE.
Collapse
|
36
|
Zampini MA, Guidetti M, Royston TJ, Klatt D. Measuring viscoelastic parameters in Magnetic Resonance Elastography: a comparison at high and low magnetic field intensity. J Mech Behav Biomed Mater 2021; 120:104587. [PMID: 34034077 DOI: 10.1016/j.jmbbm.2021.104587] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2020] [Revised: 04/21/2021] [Accepted: 05/08/2021] [Indexed: 12/21/2022]
Abstract
Magnetic Resonance Elastography (MRE) is a non-invasive imaging technique which involves motion-encoding MRI for the estimation of the shear viscoelastic properties of soft tissues through the study of shear wave propagation. The technique has been found informative for disease diagnosis, as well as for monitoring of the effects of therapies. The development of MRE and its validation have been supported by the use of tissue-mimicking phantoms. In this paper we present our new MRE protocol using a low magnetic field tabletop MRI device at 0.5 T and sinusoidal uniaxial excitation in a geometrical focusing condition. Results obtained for gelatin are compared to those previously obtained using high magnetic field MRE at 11.7 T. A multi-frequency investigation is also provided via a comparison of commonly used rheological models: Maxwell, Springpot, Voigt, Zener, Jeffrey, fractional Voigt and fractional Zener. Complex shear modulus values were comparable when processed from images acquired with the tabletop low field scanner and the high field scanner. This study serves as a validation of the presented tabletop MRE protocol and paves the way for MRE experiments on ex-vivo tissue samples in both normal and pathological conditions.
Collapse
Affiliation(s)
- Marco Andrea Zampini
- University of Illinois at Chicago, Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, 60607, USA; MR Solutions Ltd, Ashbourne House, Old Portsmouth Rd, Guildford, United Kingdom; Bio-Imaging Lab, Department of Biomedical Sciences, University of Antwerp, Universiteitsplein 1, Wilrijk, Belgium.
| | - Martina Guidetti
- University of Illinois at Chicago, Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, 60607, USA
| | - Thomas J Royston
- University of Illinois at Chicago, Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, 60607, USA
| | - Dieter Klatt
- University of Illinois at Chicago, Department of Bioengineering, University of Illinois at Chicago, Chicago, IL, 60607, USA
| |
Collapse
|
37
|
Bhushan A, Gonsalves A, Menon JU. Current State of Breast Cancer Diagnosis, Treatment, and Theranostics. Pharmaceutics 2021; 13:723. [PMID: 34069059 PMCID: PMC8156889 DOI: 10.3390/pharmaceutics13050723] [Citation(s) in RCA: 44] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2021] [Revised: 05/07/2021] [Accepted: 05/10/2021] [Indexed: 12/11/2022] Open
Abstract
Breast cancer is one of the leading causes of cancer-related morbidity and mortality in women worldwide. Early diagnosis and effective treatment of all types of cancers are crucial for a positive prognosis. Patients with small tumor sizes at the time of their diagnosis have a significantly higher survival rate and a significantly reduced probability of the cancer being fatal. Therefore, many novel technologies are being developed for early detection of primary tumors, as well as distant metastases and recurrent disease, for effective breast cancer management. Theranostics has emerged as a new paradigm for the simultaneous diagnosis, imaging, and treatment of cancers. It has the potential to provide timely and improved patient care via personalized therapy. In nanotheranostics, cell-specific targeting moieties, imaging agents, and therapeutic agents can be embedded within a single formulation for effective treatment. In this review, we will highlight the different diagnosis techniques and treatment strategies for breast cancer management and explore recent advances in breast cancer theranostics. Our main focus will be to summarize recent trends and technologies in breast cancer diagnosis and treatment as reported in recent research papers and patents and discuss future perspectives for effective breast cancer therapy.
Collapse
Affiliation(s)
- Arya Bhushan
- Ladue Horton Watkins High School, St. Louis, MO 63124, USA;
- Department of Biomedical and Pharmaceutical Sciences, College of Pharmacy, University of Rhode Island, Kingston, RI 02881, USA;
| | - Andrea Gonsalves
- Department of Biomedical and Pharmaceutical Sciences, College of Pharmacy, University of Rhode Island, Kingston, RI 02881, USA;
| | - Jyothi U. Menon
- Department of Biomedical and Pharmaceutical Sciences, College of Pharmacy, University of Rhode Island, Kingston, RI 02881, USA;
| |
Collapse
|
38
|
Abstract
Magnetic resonance (MR) imaging is a crucial tool for evaluation of the skull base, enabling characterization of complex anatomy by utilizing multiple image contrasts. Recent technical MR advances have greatly enhanced radiologists' capability to diagnose skull base pathology and help direct management. In this paper, we will summarize cutting-edge clinical and emerging research MR techniques for the skull base, including high-resolution, phase-contrast, diffusion, perfusion, vascular, zero echo-time, elastography, spectroscopy, chemical exchange saturation transfer, PET/MR, ultra-high-field, and 3D visualization. For each imaging technique, we provide a high-level summary of underlying technical principles accompanied by relevant literature review and clinical imaging examples.
Collapse
Affiliation(s)
- Claudia F Kirsch
- Division Chief, Neuroradiology, Professor of Neuroradiology and Otolaryngology, Department of Radiology, Northwell Health, Zucker Hofstra School of Medicine at Northwell, North Shore University Hospital, Manhasset, NY
| | - Mai-Lan Ho
- Associate Professor of Radiology, Director of Research, Department of Radiology, Director, Advanced Neuroimaging Core, Chair, Asian Pacific American Network, Secretary, Association for Staff and Faculty Women, Nationwide Children's Hospital and The Ohio State University, Columbus, OH; Division Chief, Neuroradiology, Professor of Neuroradiology and Otolaryngology, Department of Radiology, Northwell Health, Zucker Hofstra School of Medicine at Northwell, North Shore University Hospital, Manhasset, NY.
| |
Collapse
|
39
|
Garcés Iñigo E, Llorens Salvador R, Escrig R, Hervás D, Vento M, Martí-Bonmatí L. Quantitative Evaluation of Neonatal Brain Elasticity Using Shear Wave Elastography. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2021; 40:795-804. [PMID: 32876366 DOI: 10.1002/jum.15464] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Revised: 07/09/2020] [Accepted: 07/12/2020] [Indexed: 06/11/2023]
Abstract
OBJECTIVES To demonstrate the feasibility of 2-dimensional brain ultrasound shear wave elastography (SWE) and to define the average elasticity values of the gray and white matter in term neonates. METHODS This work was a prospective observational single-center study including 55 healthy term neonates consecutively recruited in the maternity ward between the second and third postnatal days. All were successfully evaluated with a cerebral SWE examination performed with a multifrequency 4-9-MHz transducer. Bilateral sagittal planes of the thalamus and corona radiata were used to measure stiffness using a quantitative SWE method. Several elastograms with 5 to 15 nonoverlapping areas were obtained from the 2 different anatomic locations. The 5 most central measurements were averaged as representative values. RESULTS The 55 neonates ranged from 37 to 40 weeks' gestation. The estimated mean velocity values of the thalamus (1.17 m/s; 95% confidence interval, 1.13, 1.22 m/s) and corona radiata (1.60 m/s; 95% confidence interval, 1.57, 1.64 m/s) were statistically different (P < .001). There was no significant influence of laterality, gestational age, cephalic perimeter, sex, length, or type of delivery on the stiffness measurements. CONCLUSIONS Brain ultrasound SWE is feasible and allows measurements of neonatal brain elasticity. The elasticity of the thalamus and corona radiata at the frontal white matter in healthy term neonates is different. The knowledge of normal SWE ranges in term neonates allows comparative studies under pathologic conditions.
Collapse
Affiliation(s)
| | | | - Raquel Escrig
- Department of Pediatrics, Neonatal Research Unit, Hospital Universitario y Politécnico La Fe, Valencia, Spain
| | - David Hervás
- Data Science, Biostatistics, and Bioinformatics Platform, Instituto de Investigación Sanitaria La Fe, Valencia, Spain
| | - Máximo Vento
- Department of Pediatrics, Neonatal Research Unit, Hospital Universitario y Politécnico La Fe, Valencia, Spain
| | - Luis Martí-Bonmatí
- Department of Radiology, Hospital Universitario y Politécnico La Fe, Valencia, Spain
- Research Group on Biomedical Imaging, Instituto de Investigación Sanitaria La Fe, Valencia, Spain
| |
Collapse
|
40
|
Arani A, Manduca A, Ehman RL, Huston Iii J. Harnessing brain waves: a review of brain magnetic resonance elastography for clinicians and scientists entering the field. Br J Radiol 2021; 94:20200265. [PMID: 33605783 PMCID: PMC8011257 DOI: 10.1259/bjr.20200265] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
Abstract
Brain magnetic resonance elastography (MRE) is an imaging technique capable of accurately and non-invasively measuring the mechanical properties of the living human brain. Recent studies have shown that MRE has potential to provide clinically useful information in patients with intracranial tumors, demyelinating disease, neurodegenerative disease, elevated intracranial pressure, and altered functional states. The objectives of this review are: (1) to give a general overview of the types of measurements that have been obtained with brain MRE in patient populations, (2) to survey the tools currently being used to make these measurements possible, and (3) to highlight brain MRE-based quantitative biomarkers that have the highest potential of being adopted into clinical use within the next 5 to 10 years. The specifics of MRE methodology strategies are described, from wave generation to material parameter estimations. The potential clinical role of MRE for characterizing and planning surgical resection of intracranial tumors and assessing diffuse changes in brain stiffness resulting from diffuse neurological diseases and altered intracranial pressure are described. In addition, the emerging technique of functional MRE, the role of artificial intelligence in MRE, and promising applications of MRE in general neuroscience research are presented.
Collapse
Affiliation(s)
- Arvin Arani
- Department of Radiology, Mayo Clinic, Rochester, MN, USA
| | - Armando Manduca
- Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA
| | | | | |
Collapse
|
41
|
Wymer DT, Patel KP, Burke WF, Bhatia VK. Phase-Contrast MRI: Physics, Techniques, and Clinical Applications. Radiographics 2021; 40:122-140. [PMID: 31917664 DOI: 10.1148/rg.2020190039] [Citation(s) in RCA: 61] [Impact Index Per Article: 20.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
With phase-contrast imaging, the MRI signal is used to visualize and quantify velocity. This imaging modality relies on phase data, which are intrinsic to all MRI signals. With use of bipolar gradients, degrees of phase shift are encoded and in turn correlated directly with the velocity of protons. The acquisition of diagnostic-quality images requires selection of the correct imaging plane to ensure accurate measurement and selection of the encoding velocity and thus prevent aliasing and achieve the highest signal-to-noise ratio. Multiple applications of phase-contrast imaging are actively used in clinical practice. One of the most common clinical uses is in cardiac valvular flow imaging, at which the data are used to assess the severity of valvular disease and quantify the shunt fraction. In neurologic imaging, phase-contrast imaging can be used to measure the flow of cerebrospinal fluid. This measurement can aid in the diagnosis and direct management of normal pressure hydrocephalus or be used to evaluate the severity of stenosis, such as that in Chiari I malformations. At vascular analysis, phase-contrast imaging can be used to visualize arterial and venous flow, and this application is used most commonly in the brain. Three-dimensional imaging can yield highly detailed flow data in a technique referred to as four-dimensional flow. A more recently identified application is in MR elastography. Shear waves created by using an impulse device can be velocity encoded, and this velocity is directly proportional to the stiffness of the organ, or the shear modulus. This imaging modality is most commonly used in the liver for evaluation of cirrhosis and steatosis, although research on the assessment of other organs is being performed. Phase-contrast imaging is an important tool in the arsenal of MRI examinations and has many applications. Proper use of phase-contrast imaging requires an understanding of the many practical and technical factors and unique physics principles underlying the technique.©RSNA, 2020.
Collapse
Affiliation(s)
- David T Wymer
- From the Department of Diagnostic Radiology, Mount Sinai Medical Center, 4300 Alton Rd, Miami Beach, FL 33140
| | - Kunal P Patel
- From the Department of Diagnostic Radiology, Mount Sinai Medical Center, 4300 Alton Rd, Miami Beach, FL 33140
| | - William F Burke
- From the Department of Diagnostic Radiology, Mount Sinai Medical Center, 4300 Alton Rd, Miami Beach, FL 33140
| | - Vinay K Bhatia
- From the Department of Diagnostic Radiology, Mount Sinai Medical Center, 4300 Alton Rd, Miami Beach, FL 33140
| |
Collapse
|
42
|
Sango Solanas P, Tse Ve Koon K, Ratiney H, Millioz F, Caussy C, Beuf O. Harmonic wideband simultaneous dual-frequency MR Elastography. NMR IN BIOMEDICINE 2021; 34:e4442. [PMID: 33179393 DOI: 10.1002/nbm.4442] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Revised: 10/21/2020] [Accepted: 10/21/2020] [Indexed: 06/11/2023]
Abstract
Magnetic resonance elastography (MRE) is used to non-invasively quantify viscoelastic properties of tissues based on the measurement of propagation characteristics of shear waves. Because some of these viscoelastic parameters show a frequency dependence, multifrequency analysis allows us to measure the wave propagation dispersion, leading to a better characterization of tissue properties. Conventionally, motion encoding gradients (MEGs) oscillating at the same frequency as the mechanical excitation encode motion. Hence, multifrequency data is usually obtained by sequentially repeating monochromatic wave excitations experiments at different frequencies. The result is that the total acquisition time is multiplied by a factor corresponding to the number of repetitions of monofrequency experiments, which is a major limitation of multifrequency MRE. In order to make it more accessible, a novel single-shot harmonic wideband dual-frequency MRE method is proposed. Two superposed shear waves of different frequencies are simultaneously generated and propagate in a sample. Trapezoidal oscillating MEGs are used to encode mechanical vibrations having frequencies that are an odd multiple of the MEG frequency. The number of phase offsets is optimized to reduce the acquisition time. For this purpose, a sampling method not respecting the Shannon theorem is used to produce a controlled temporal aliasing that allows us to encode both frequencies without any additional examination time. Phantom experiments were run to compare conventional monofrequency MRE with the single-shot dual-frequency MRE method and showed excellent agreement between the reconstructed shear storage moduli G'. In addition, dual-frequency MRE yielded an increased signal-to-noise ratio compared with conventional monofrequency MRE acquisitions when encoding the high frequency component. The novel proposed multifrequency MRE method could be applied to simultaneously acquire more than two frequency components, reducing examination time. Further studies are needed to confirm its applicability in preclinical and clinical models.
Collapse
Affiliation(s)
- Pilar Sango Solanas
- Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| | - Kevin Tse Ve Koon
- Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| | - Helene Ratiney
- Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| | - Fabien Millioz
- Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| | - Cyrielle Caussy
- Univ Lyon, CarMen Laboratory, INSERM, INRA, INSA Lyon, Université Claude Bernard Lyon 1, Pierre-Bénite, France
- Hospices Civils de Lyon, Département Endocrinologie, Diabète et Nutrition, Hôpital Lyon Sud, Pierre-Bénite, France
| | - Olivier Beuf
- Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, France
| |
Collapse
|
43
|
Zeng Q, Honarvar M, Schneider C, Mohammad SK, Lobo J, Pang EHT, Lau KT, Hu C, Jago J, Erb SR, Rohling R, Salcudean SE. Three-Dimensional Multi-Frequency Shear Wave Absolute Vibro-Elastography (3D S-WAVE) With a Matrix Array Transducer: Implementation and Preliminary In Vivo Study of the Liver. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:648-660. [PMID: 33108283 DOI: 10.1109/tmi.2020.3034065] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Magnetic resonance elastography (MRE) is commonly regarded as the imaging-based gold-standard for liver fibrosis staging, comparable to biopsy. While ultrasound-based elastography methods for liver fibrosis staging have been developed, they are confined to a 1D or a 2D region of interest and to a limited depth. 3D Shear Wave Absolute Vibro-Elastography (S-WAVE) is a steady-state, external excitation, volumetric elastography technique that is similar to MRE, but has the additional advantage of multi-frequency excitation. We present a novel ultrasound matrix array implementation of S-WAVE that takes advantage of 3D imaging. We use a matrix array transducer to sample axial multi-frequency steady-state tissue motion over a volume, using a Color Power Angiography sequence. Tissue motion with the frequency components {40,50,60} and {45,55,65} Hz are acquired over a (90° lateral) × (40° elevational) × (16 cm depth) sector with an acquisition time of 12 seconds. We compute the elasticity map in 3D using local spatial frequency estimation. We characterize this new approach in tissue phantoms against measurements obtained with transient elastography and MRE. Six healthy volunteers and eight patients with chronic liver disease were imaged. Their MRE and S-WAVE volumes were aligned using T1 to B-mode registration for direct comparison in common regions of interest. S-WAVE and MRE results are correlated with R2 = 0.92, while MRE and TE results are correlated with R2 = 0.71. Our findings show that S-WAVE with matrix array has the potential to deliver a similar assessment of liver fibrosis as MRE in a more accessible, inexpensive way, to a broader set of patients.
Collapse
|
44
|
McGarry MDJ, Campo A, Payen T, Han Y, Konofagou EE. An analytical model of full-field displacement and strain induced by amplitude-modulated focused ultrasound in harmonic motion imaging. Phys Med Biol 2021; 66. [PMID: 33472178 DOI: 10.1088/1361-6560/abddd1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Accepted: 01/20/2021] [Indexed: 11/12/2022]
Abstract
The majority of disease processes involves changes in the micro-structure of the affected tissue, which can translate to changes in the mechanical properties of the corresponding tissue. Harmonic motion imaging (HMI) is an elasticity imaging technique that allows the study of the mechanical parameters of tissue by detecting the tissue response by a harmonic motion field, which is generated by oscillatory acoustic radiation force (ARF). HMI has been demonstrated in tumor detection and characterization as well as monitoring of ablation procedures. In this study, an analytical HMI model is demonstrated and compared with a finite element model (FEM), allowing rapid and accurate computation of the displacement, strain, and shear wave velocity (SWV) at any location in a homogeneous linear elastic material. Average absolute differences between the analytical model and the FEM were respectively 1.2 % for the displacements and 0.5 % for the strains for 41940 force voxels at 0.22 seconds per displacement evaluation. A convergence study showed that the average difference could be further decreased to 1.0 % and 0.15 % for the displacements and strains, respectively, if force resolution is increased. SWV fields, as calculated with the FEM and the analytical model, have regional differences in velocities up to 0.57 m/s with an average absolute difference of 0.11±0.07 m/s, primarily due to imperfections in the non-reflecting FEM boundary conditions. The apparent SWV differed from the commonly used plane-wave approximation by up to 1.2 m/s due to near and intermediate field effects. Maximum displacement amplitudes for a model with an inclusion stabilize within 10 % of the homogeneous model at an inclusion radius of 10 mm while the maximum strain reacts faster, stabilizing at an inclusion radius of 3 mm. In conclusion, an analytical model for HMI stiffness estimation is presented in this paper. The analytical model has advantages over FEM as the full-field displacements do not need to be calculated to evaluate the model at a single measurement point. This advantage, together with the computational speed, makes the analytical model useful for real-time imaging applications. However, the analytical model was found to have restrictive assumptions on tissue homogeneity and infinite dimensions, while the FEM approaches were shown adaptable to variable geometry and non-homogeneous properties.
Collapse
Affiliation(s)
- Matthew D J McGarry
- Biomedical Engineering, Columbia University, New York, New York, 10027-6902, UNITED STATES
| | - Adriaan Campo
- Faculty of Science, Universiteit Antwerpen, Groenenborgerlaan 171, 2020 Antwerp, antwerpen, BELGIUM
| | - Thomas Payen
- Biomedical engineering, Columbia University, 630 w 168th street, New York, New York, 10032, UNITED STATES
| | - Yang Han
- Biomedical Engineering, Columbia Univerisity, 630 West 168th Street Physicians & Surgeons 19-418, New York, New York, 10032, UNITED STATES
| | - Elisa E Konofagou
- Department of Biomedical Engineering, Columbia University, MC 8904, 351 Engineering Terrace, 1210 Amsterdam Avenue, New York, NY 10027, USA, New York, New York, UNITED STATES
| |
Collapse
|
45
|
Troelstra MA, Runge JH, Burnhope E, Polcaro A, Guenthner C, Schneider T, Razavi R, Ismail TF, Martorell J, Sinkus R. Shear wave cardiovascular MR elastography using intrinsic cardiac motion for transducer-free non-invasive evaluation of myocardial shear wave velocity. Sci Rep 2021; 11:1403. [PMID: 33446701 PMCID: PMC7809276 DOI: 10.1038/s41598-020-79231-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Accepted: 11/30/2020] [Indexed: 01/29/2023] Open
Abstract
Changes in myocardial stiffness may represent a valuable biomarker for early tissue injury or adverse remodeling. In this study, we developed and validated a novel transducer-free magnetic resonance elastography (MRE) approach for quantifying myocardial biomechanics using aortic valve closure-induced shear waves. Using motion-sensitized two-dimensional pencil beams, septal shear waves were imaged at high temporal resolution. Shear wave speed was measured using time-of-flight of waves travelling between two pencil beams and corrected for geometrical biases. After validation in phantoms, results from twelve healthy volunteers and five cardiac patients (two left ventricular hypertrophy, two myocardial infarcts, and one without confirmed pathology) were obtained. Torsional shear wave speed in the phantom was 3.0 ± 0.1 m/s, corresponding with reference speeds of 2.8 ± 0.1 m/s. Geometrically-biased flexural shear wave speed was 1.9 ± 0.1 m/s, corresponding with simulation values of 2.0 m/s. Corrected septal shear wave speeds were significantly higher in patients than healthy volunteers [14.1 (11.0-15.8) m/s versus 3.6 (2.7-4.3) m/s, p = 0.001]. The interobserver 95%-limits-of-agreement in healthy volunteers were ± 1.3 m/s and interstudy 95%-limits-of-agreement - 0.7 to 1.2 m/s. In conclusion, myocardial shear wave speed can be measured using aortic valve closure-induced shear waves, with cardiac patients showing significantly higher shear wave speeds than healthy volunteers. This non-invasive measure may provide valuable insights into the pathophysiology of heart failure.
Collapse
Affiliation(s)
- Marian Amber Troelstra
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Jurgen Henk Runge
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, Amsterdam, The Netherlands
| | - Emma Burnhope
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Department of Cardiology, Guy's and St Thomas' NHS Foundation Trust, London, UK
| | - Alessandro Polcaro
- Department of Chemical Engineering and Material Sciences, IQS School of Engineering, Universitat Ramon Llull, Via Augusta 390, 08017, Barcelona, Spain
| | - Christian Guenthner
- Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland
- Philips Research, Hamburg, Germany
| | - Torben Schneider
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Philips, Guildford, UK
| | - Reza Razavi
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
| | - Tevfik F Ismail
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Department of Cardiology, Guy's and St Thomas' NHS Foundation Trust, London, UK
| | - Jordi Martorell
- Department of Chemical Engineering and Material Sciences, IQS School of Engineering, Universitat Ramon Llull, Via Augusta 390, 08017, Barcelona, Spain.
| | - Ralph Sinkus
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK
- Inserm U1148, LVTS, University Paris Diderot, University Paris 13, Paris, France
| |
Collapse
|
46
|
MR Elastography. Mol Imaging 2021. [DOI: 10.1016/b978-0-12-816386-3.00058-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
47
|
Kazerouni AS, Gadde M, Gardner A, Hormuth DA, Jarrett AM, Johnson KE, Lima EAF, Lorenzo G, Phillips C, Brock A, Yankeelov TE. Integrating Quantitative Assays with Biologically Based Mathematical Modeling for Predictive Oncology. iScience 2020; 23:101807. [PMID: 33299976 PMCID: PMC7704401 DOI: 10.1016/j.isci.2020.101807] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022] Open
Abstract
We provide an overview on the use of biological assays to calibrate and initialize mechanism-based models of cancer phenomena. Although artificial intelligence methods currently dominate the landscape in computational oncology, mathematical models that seek to explicitly incorporate biological mechanisms into their formalism are of increasing interest. These models can guide experimental design and provide insights into the underlying mechanisms of cancer progression. Historically, these models have included a myriad of parameters that have been difficult to quantify in biologically relevant systems, limiting their practical insights. Recently, however, there has been much interest calibrating biologically based models with the quantitative measurements available from (for example) RNA sequencing, time-resolved microscopy, and in vivo imaging. In this contribution, we summarize how a variety of experimental methods quantify tumor characteristics from the molecular to tissue scales and describe how such data can be directly integrated with mechanism-based models to improve predictions of tumor growth and treatment response.
Collapse
Affiliation(s)
- Anum S. Kazerouni
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX 78712, USA
| | - Manasa Gadde
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX 78712, USA
- Department of Diagnostic Medicine, The University of Texas at Austin, Austin, TX 78712, USA
| | - Andrea Gardner
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX 78712, USA
| | - David A. Hormuth
- Oden Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, TX 78712, USA
- Livestrong Cancer Institutes, The University of Texas at Austin, Austin, TX 78712, USA
| | - Angela M. Jarrett
- Oden Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, TX 78712, USA
- Livestrong Cancer Institutes, The University of Texas at Austin, Austin, TX 78712, USA
| | - Kaitlyn E. Johnson
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX 78712, USA
| | - Ernesto A.B. F. Lima
- Oden Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, TX 78712, USA
- Texas Advanced Computing Center, The University of Texas at Austin, Austin, TX 78712, USA
| | - Guillermo Lorenzo
- Oden Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, TX 78712, USA
| | - Caleb Phillips
- Oden Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, TX 78712, USA
| | - Amy Brock
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX 78712, USA
- Livestrong Cancer Institutes, The University of Texas at Austin, Austin, TX 78712, USA
| | - Thomas E. Yankeelov
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX 78712, USA
- Department of Diagnostic Medicine, The University of Texas at Austin, Austin, TX 78712, USA
- Department of Oncology, The University of Texas at Austin, Austin, TX 78712, USA
- Oden Institute for Computational Engineering and Sciences, The University of Texas at Austin, Austin, TX 78712, USA
- Livestrong Cancer Institutes, The University of Texas at Austin, Austin, TX 78712, USA
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX 77030, USA
| |
Collapse
|
48
|
Manduca A, Bayly PJ, Ehman RL, Kolipaka A, Royston TJ, Sack I, Sinkus R, Van Beers BE. MR elastography: Principles, guidelines, and terminology. Magn Reson Med 2020; 85:2377-2390. [PMID: 33296103 DOI: 10.1002/mrm.28627] [Citation(s) in RCA: 79] [Impact Index Per Article: 19.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 10/20/2020] [Accepted: 11/09/2020] [Indexed: 12/13/2022]
Abstract
Magnetic resonance elastography (MRE) is a phase contrast-based MRI technique that can measure displacement due to propagating mechanical waves, from which material properties such as shear modulus can be calculated. Magnetic resonance elastography can be thought of as quantitative, noninvasive palpation. It is increasing in clinical importance, has become widespread in the diagnosis and staging of liver fibrosis, and additional clinical applications are being explored. However, publications have reported MRE results using many different parameters, acquisition techniques, processing methods, and varied nomenclature. The diversity of terminology can lead to confusion (particularly among clinicians) about the meaning of and interpretation of MRE results. This paper was written by the MRE Guidelines Committee, a group formalized at the first meeting of the ISMRM MRE Study Group, to clarify and move toward standardization of MRE nomenclature. The purpose of this paper is to (1) explain MRE terminology and concepts to those not familiar with them, (2) define "good practices" for practitioners of MRE, and (3) identify opportunities to standardize terminology, to avoid confusion.
Collapse
Affiliation(s)
- Armando Manduca
- Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota, USA
| | - Philip J Bayly
- Mechanical Engineering and Materials Science, Washington University in St. Louis, St. Louis, Missouri, USA
| | - Richard L Ehman
- Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota, USA
| | - Arunark Kolipaka
- Department of Radiology, Ohio State University, Columbus, Ohio, USA
| | - Thomas J Royston
- Department of Bioengineering, University of Illinois at Chicago, Chicago, Illinois, USA
| | - Ingolf Sack
- Charité-Universitätsmedizin Berlin, Berlin, Germany
| | - Ralph Sinkus
- Imaging Sciences & Biomedical Engineering, Kings College London, London, United Kingdom
| | | |
Collapse
|
49
|
Plaikner M, Kremser C, Viveiros A, Zoller H, Henninger B. [Magnetic resonance elastography of the liver : Worth knowing for clinical routine]. Radiologe 2020; 60:966-978. [PMID: 32399783 DOI: 10.1007/s00117-020-00690-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND Magnetic resonance elastography (MRE) is a noninvasive, quantitative, MRI-based method to evaluate liver stiffness. Beside biopsy and ultrasound elastography, this imaging method plays in many places a significant role in the detection and additive characterization of chronic liver disease. OBJECTIVES, MATERIALS AND METHODS Based on the literature, a brief review of the underlying method and the commercially available products is given. Furthermore, the practical procedure, the analysis, and the interpretation of clinically relevant questions are illustrated and a comparison with ultrasound elastography is provided. RESULTS This relative "young" MRI method allows extensive evaluation of mechanical properties of the liver and is an important diagnostic tool especially in follow-up examinations. The MRE of the liver is with a maximum technical failure rate of 5.8% a robust technique with high accuracy and an excellent re-test reliability as well as intra- and interobserver reproducibility. There is a high diagnostic certainty within the framework of most important clinical indications, the quantification of fibrosis, and with a very good correlation with the "gold standard" biopsy. CONCLUSION Based on its rising clinical relevance and the broad usage, MRE of the liver is increasingly used in many centers and in routine liver protocols. Therefore, basic knowledge of this method is essential for every radiologist.
Collapse
Affiliation(s)
- Michaela Plaikner
- Radiologie, Medizinische Universität Innsbruck, Anichstraße 35, 6020, Innsbruck, Österreich.
| | - Christian Kremser
- Radiologie, Medizinische Universität Innsbruck, Anichstraße 35, 6020, Innsbruck, Österreich
| | - André Viveiros
- Innere Medizin I, Medizinische Universität Innsbruck, Anichstraße 35, 6020, Innsbruck, Österreich
| | - Heinz Zoller
- Innere Medizin I, Medizinische Universität Innsbruck, Anichstraße 35, 6020, Innsbruck, Österreich
| | - Benjamin Henninger
- Radiologie, Medizinische Universität Innsbruck, Anichstraße 35, 6020, Innsbruck, Österreich
| |
Collapse
|
50
|
Malattia C, Tolend M, Mazzoni M, Panwar J, Zlotnik M, Otobo T, Vidarsson L, Doria AS. Current status of MR imaging of juvenile idiopathic arthritis. Best Pract Res Clin Rheumatol 2020; 34:101629. [PMID: 33281052 DOI: 10.1016/j.berh.2020.101629] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Juvenile idiopathic arthritis (JIA) is the most common chronic arthropathy in the pediatric population. Although the diagnosis is essentially clinical for many affected joints, MR imaging has become an important tool for the assessment of joints that are difficult to evaluate clinically, such as temporomandibular and sacroiliac joints, and for screening of inflammatory changes in the entire body by whole body MRI (WBMRI) assessment. The utilization of MR imaging is challenging in the pediatric population given the need for discrimination between pathological and physiological changes in the growing skeleton. Several multicentric multidisciplinary organizations have made major efforts over the past decades to standardize, quantify, and validate scoring systems to measure joint changes both cross-sectionally and longitudinally according to rigorous methodological standards. In this paper, we (1) discuss current trends for the diagnosis and management of JIA, (2) review challenges for detecting real pathological changes in growing joints, (3) summarize the current status of standardization of MRI protocols for data acquisition and the quantification of joint pathology in JIA by means of scoring systems, and (4) outline novel MR imaging techniques for the evaluation of anatomy and function of joints in JIA. Optimizing the role of MRI as a robust biomarker and outcome measure remains a priority of future research in this field.
Collapse
Affiliation(s)
- Clara Malattia
- Clinica Pediatrica e Reumatologia, Istituto Giannina Gaslini, Genoa, Italy; Department of Neurosciences, Rehabilitation, Ophthalmology, Genetic and Maternal Infantile Sciences (DINOGMI), University of Genoa, Italy
| | - Mirkamal Tolend
- Department of Diagnostic Imaging, Research Institute, The Hospital for Sick Children, Toronto, ON, Canada
| | - Marta Mazzoni
- Clinica Pediatrica e Reumatologia, Istituto Giannina Gaslini, Genoa, Italy; Department of Neurosciences, Rehabilitation, Ophthalmology, Genetic and Maternal Infantile Sciences (DINOGMI), University of Genoa, Italy
| | - Jyoti Panwar
- Department of Radiology, Christian Medical College, Vellore, India
| | - Margalit Zlotnik
- Department of Diagnostic Imaging, Research Institute, The Hospital for Sick Children, Toronto, ON, Canada
| | - Tarimobo Otobo
- Department of Diagnostic Imaging, Research Institute, The Hospital for Sick Children, Toronto, ON, Canada
| | - Logi Vidarsson
- Department of Diagnostic Imaging, Research Institute, The Hospital for Sick Children, Toronto, ON, Canada
| | - Andrea S Doria
- Department of Diagnostic Imaging, Research Institute, The Hospital for Sick Children, Toronto, ON, Canada; Department of Medical Imaging, University of Toronto, Toronto, ON, Canada.
| |
Collapse
|