1
|
Anderson KD, Beckmann C, Heermant S, Ko FC, Dulion B, Tarhoni I, Borgia JA, Virdi AS, Wimmer MA, Sumner DR, Ross RD. Zucker Diabetic-Sprague Dawley Rats Have Impaired Peri-Implant Bone Formation, Matrix Composition, and Implant Fixation Strength. JBMR Plus 2023; 7:e10819. [PMID: 38025036 PMCID: PMC10652173 DOI: 10.1002/jbm4.10819] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 08/14/2023] [Accepted: 08/31/2023] [Indexed: 12/01/2023] Open
Abstract
An increasing number of patients with type 2 diabetes (T2DM) will require total joint replacement (TJR) in the next decade. T2DM patients are at increased risk for TJR failure, but the mechanisms are not well understood. The current study used the Zucker Diabetic-Sprague Dawley (ZDSD) rat model of T2DM with Sprague Dawley (SPD) controls to investigate the effects of intramedullary implant placement on osseointegration, peri-implant bone structure and matrix composition, and fixation strength at 2 and 10 weeks post-implant placement. Postoperative inflammation was assessed with circulating MCP-1 and IL-10 2 days post-implant placement. In addition to comparing the two groups, stepwise linear regression modeling was performed to determine the relative contribution of glucose, cytokines, bone formation, bone structure, and bone matrix composition on osseointegration and implant fixation strength. ZDSD rats had decreased peri-implant bone formation and reduced trabecular bone volume per total volume compared with SPD controls. The osseointegrated bone matrix of ZDSD rats had decreased mineral-to-matrix and increased crystallinity compared with SPD controls. Osseointegrated bone volume per total volume was not different between the groups, whereas implant fixation was significantly decreased in ZDSD at 2 weeks but not at 10 weeks. A combination of trabecular mineral apposition rate and postoperative MCP-1 levels explained 55.6% of the variance in osseointegration, whereas cortical thickness, osseointegration mineral apposition rate, and matrix compositional parameters explained 69.2% of the variance in implant fixation strength. The results support the growing recognition that both peri-implant structure and matrix composition affect implant fixation and suggest that postoperative inflammation may contribute to poor outcomes after TJR surgeries in T2DM patients. © 2023 The Authors. JBMR Plus published by Wiley Periodicals LLC on behalf of American Society for Bone and Mineral Research.
Collapse
Affiliation(s)
- Kyle D Anderson
- Department of Anatomy and Cell BiologyRush University Medical CenterChicagoILUSA
| | - Christian Beckmann
- Department of Orthopedic SurgeryRush University Medical CenterChicagoILUSA
| | - Saskia Heermant
- Department of Orthopedic SurgeryRush University Medical CenterChicagoILUSA
| | - Frank C Ko
- Department of Anatomy and Cell BiologyRush University Medical CenterChicagoILUSA
- Department of Orthopedic SurgeryRush University Medical CenterChicagoILUSA
| | - Bryan Dulion
- Department of Anatomy and Cell BiologyRush University Medical CenterChicagoILUSA
| | - Imad Tarhoni
- Department of Anatomy and Cell BiologyRush University Medical CenterChicagoILUSA
| | - Jeffrey A Borgia
- Department of Anatomy and Cell BiologyRush University Medical CenterChicagoILUSA
| | - Amarjit S Virdi
- Department of Anatomy and Cell BiologyRush University Medical CenterChicagoILUSA
- Department of Orthopedic SurgeryRush University Medical CenterChicagoILUSA
| | - Markus A Wimmer
- Department of Orthopedic SurgeryRush University Medical CenterChicagoILUSA
| | - D Rick Sumner
- Department of Anatomy and Cell BiologyRush University Medical CenterChicagoILUSA
- Department of Orthopedic SurgeryRush University Medical CenterChicagoILUSA
| | - Ryan D Ross
- Department of Anatomy and Cell BiologyRush University Medical CenterChicagoILUSA
- Department of Orthopedic SurgeryRush University Medical CenterChicagoILUSA
- Department of Microbial Pathogens and ImmunityRush University Medical CenterChicagoILUSA
| |
Collapse
|
2
|
Yamada C, Ho A, Akkaoui J, Garcia C, Duarte C, Movila A. Glycyrrhizin mitigates inflammatory bone loss and promotes expression of senescence-protective sirtuins in an aging mouse model of periprosthetic osteolysis. Biomed Pharmacother 2021; 138:111503. [PMID: 33770668 PMCID: PMC8653540 DOI: 10.1016/j.biopha.2021.111503] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2020] [Revised: 03/08/2021] [Accepted: 03/11/2021] [Indexed: 01/02/2023] Open
Abstract
Although periprosthetic osteolysis induced by wear debris particles is significantly elevated in senior (65+ years old) patients, most of the published pre-clinical studies were performed using young (less than three-month old) mice indicating the critical need to employ experimental models of particle-induced osteolysis involving mice with advanced age. Emerging evidence indicates that currently available antiresorptive bone therapies have serious age-dependent side effects. However, a resurgence of healthcare interest has occurred in glycyrrhizin (GLY), a natural extract from the licorice roots, as alternative sources of drugs for treating inflammatory bone lytic diseases and prevention of cellular senescence. This study investigated the effects of GLY on inflammatory bone loss as well as expression patterns of senescence-associated secretory phenotype and senescence-protective markers using an experimental calvarium osteolytic model induced in aged (twenty-four-month-old) mice by polymethylmethacrylate (PMMA) particles. Our results indicate that local treatment with GLY significantly diminished the size of inflammatory osteolytic lesions in aged mice via the number of CXCR4+OCPs and Tartrate-resistant acid phosphatase positive (TRAP+) osteoclasts. Furthermore, GLY dramatically decreased the amounts of senescence-associated secretory phenotype markers, including pro-inflammatory macrophage migration inhibitory factor (MIF) chemokine, and cathepsins B and K in the bone lesions of aged mice. By contrast, GLY significantly elevated expression patterns of senescence-protective markers, including homeostatic stromal derived factor-1 (SDF-1) chemokine, and sirtuin-1, and sirtuin-6, in the PMMA particle-induced calvarial lesions of aged mice. Collectively, these data suggest that GLY can be used for the development of novel therapies to control bone loss and tissue aging in senior patients with periprosthetic osteolysis.
Collapse
Affiliation(s)
- Chiaki Yamada
- Department of Oral Science and Translational Research, College of Dental Medicine, Nova Southeastern University, Fort Lauderdale, FL 33314, United States
| | - Anny Ho
- Department of Oral Science and Translational Research, College of Dental Medicine, Nova Southeastern University, Fort Lauderdale, FL 33314, United States
| | - Juliet Akkaoui
- Department of Oral Science and Translational Research, College of Dental Medicine, Nova Southeastern University, Fort Lauderdale, FL 33314, United States
| | - Christopher Garcia
- Department of Oral Science and Translational Research, College of Dental Medicine, Nova Southeastern University, Fort Lauderdale, FL 33314, United States
| | - Carolina Duarte
- Department of Oral Science and Translational Research, College of Dental Medicine, Nova Southeastern University, Fort Lauderdale, FL 33314, United States
| | - Alexandru Movila
- Department of Oral Science and Translational Research, College of Dental Medicine, Nova Southeastern University, Fort Lauderdale, FL 33314, United States.
| |
Collapse
|
3
|
Wear of hip prostheses increases serum IGFBP-1 levels in patients with aseptic loosening. Sci Rep 2021; 11:576. [PMID: 33436773 PMCID: PMC7804331 DOI: 10.1038/s41598-020-79813-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Accepted: 12/01/2020] [Indexed: 11/19/2022] Open
Abstract
The biological mechanisms involved in aseptic loosening include inflammation-associated and bone resorption-associated processes. Coordinated cellular actions result in biochemical imbalances with devastating consequences for the joint. Given that this condition is not known for showing systemic signs, we investigated whether circulating levels of inflammation-related proteins are altered in patients with aseptic loosening. Our study included 37 patients who underwent revision surgery due to hip osteolysis and aseptic loosening and 31 patients who underwent primary total hip arthroplasty. Using antibody arrays, we evaluated the serum levels of 320 proteins in four patients from each group. The results showed differences in insulin-like growth factor-binding protein 1 (IGFBP-1) concentrations, which we then quantified using enzyme-linked immunosorbent assay tests in all study patients. The results confirmed that serum IGFBP-1 concentrations were higher in the revision surgery patients than in the hip arthroplasty patients. In vitro studies showed that exposure of human osteoblasts to titanium particles induced an IGFBP-1 release that further increased when exposure to particles was performed in media conditioned by human M1 macrophages. These findings suggest that elevated serum IGFBP-1 levels in patients with aseptic loosening can arise from increased local IGFBP-1 production in the inflammatory environment of the periprosthetic bed.
Collapse
|
4
|
Moran MM, Wilson BM, Li J, Engen PA, Naqib A, Green SJ, Virdi AS, Plaas A, Forsyth CB, Keshavarzian A, Sumner DR. The gut microbiota may be a novel pathogenic mechanism in loosening of orthopedic implants in rats. FASEB J 2020; 34:14302-14317. [PMID: 32931052 DOI: 10.1096/fj.202001364r] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2020] [Revised: 07/29/2020] [Accepted: 08/07/2020] [Indexed: 01/08/2023]
Abstract
Particles released from implants cause inflammatory bone loss, which is a key factor in aseptic loosening, the most common reason for joint replacement failure. With the anticipated increased incidence of total joint replacement in the next decade, implant failure will continue to burden patients. The gut microbiome is increasingly recognized as an important factor in bone physiology, however, its role in implant loosening is currently unknown. We tested the hypothesis that implant loosening is associated with changes in the gut microbiota in a preclinical model. When the particle challenge caused local joint inflammation, decreased peri-implant bone volume, and decreased implant fixation, the gut microbiota was affected. When the particle challenge did not cause this triad of local effects, the gut microbiota was not affected. Our results suggest that cross-talk between these compartments is a previously unrecognized mechanism of failure following total joint replacement.
Collapse
Affiliation(s)
- Meghan M Moran
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL, USA
| | - Brittany M Wilson
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL, USA
| | - Jun Li
- Department of Internal Medicine, Division of Rheumatology, Rush Medical College, Rush University Medical Center, Chicago, IL, USA
| | - Phillip A Engen
- Department of Internal Medicine, Division of Digestive Diseases and Nutrition, Rush Medical College, Chicago, IL, USA
| | - Ankur Naqib
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL, USA.,Department of Internal Medicine, Division of Digestive Diseases and Nutrition, Rush Medical College, Chicago, IL, USA
| | - Stefan J Green
- Genome Research Core, Research Resources Center, University of Illinois-Chicago, Chicago, IL, USA
| | - Amarjit S Virdi
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL, USA
| | - Anna Plaas
- Department of Internal Medicine, Division of Rheumatology, Rush Medical College, Rush University Medical Center, Chicago, IL, USA
| | - Christopher B Forsyth
- Department of Internal Medicine, Division of Digestive Diseases and Nutrition, Rush Medical College, Chicago, IL, USA
| | - Ali Keshavarzian
- Department of Internal Medicine, Division of Digestive Diseases and Nutrition, Rush Medical College, Chicago, IL, USA
| | - Dale R Sumner
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL, USA
| |
Collapse
|
5
|
Wilson BM, Moran MM, Meagher MJ, Ross RD, Mashiatulla M, Virdi AS, Sumner DR. Early changes in serum osteocalcin and body weight are predictive of implant fixation in a rat model of implant loosening. J Orthop Res 2020; 38:1216-1227. [PMID: 31825107 PMCID: PMC7225033 DOI: 10.1002/jor.24563] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2019] [Accepted: 11/30/2019] [Indexed: 02/04/2023]
Abstract
Biomarkers are of interest to identify patients at risk for peri-implant osteolysis and aseptic loosening. We used a rat model of particle-induced peri-implant osteolysis to investigate if early changes in biomarkers were associated with subsequent implant fixation strength. Implants were placed in rat femora, which were then challenged with intra-articular knee injections of either clean polyethylene, lipopolysaccharide-doped polyethylene, or cobalt-chromium alloy particles, with particle-free vehicle serving as control (n ≥ 8 per group). Rats were weighed weekly, blood was collected at weeks 0, 3, 5, and 6, and locomotor behavior was assessed 4 days before study conclusion. Rats were euthanized 6 weeks post surgery. Week 6 serum was analyzed for five bone remodeling markers, while longitudinal serum was assessed for osteocalcin. Bone-implant contact, peri-implant trabecular architecture, and implant fixation strength were measured. Rats challenged with cobalt-chromium particles had a significant reduction in implant fixation strength compared with the vehicle-control group (P = .034). This group also had elevated serum osteocalcin (P = .005), depressed weight gain (P = .001) and less frequent rearing behavior (P = .029). Regardless of group, change in serum osteocalcin at week 3 (r = -.368; P = .046), change in weight at week 2 (r = .586; P < .001), as well as weight change at all other time intervals were associated with fixation strength. The finding that early alterations in serum osteocalcin and body weight were predictive of subsequent implant fixation strength supports continued investigation of biomarkers for early detection of peri-implant osteolysis and implant loosening. Further, change in biomarker levels was found to be more indicative of implant fixation status than any single measurement.
Collapse
Affiliation(s)
- Brittany M. Wilson
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL
| | - Meghan M. Moran
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL.,Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| | - Matthew J. Meagher
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL
| | - Ryan D. Ross
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL.,Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| | - Maleeha Mashiatulla
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL
| | - Amarjit S. Virdi
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL.,Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| | - D. Rick Sumner
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL.,Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL
| |
Collapse
|
6
|
Ross RD, Deng Y, Fang R, Frisch NB, Jacobs JJ, Sumner DR. Discovery of biomarkers to identify peri-implant osteolysis before radiographic diagnosis. J Orthop Res 2018; 36:2754-2761. [PMID: 29873110 PMCID: PMC6482967 DOI: 10.1002/jor.24044] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2018] [Accepted: 05/07/2018] [Indexed: 02/04/2023]
Abstract
Peri-implant osteolysis is commonly diagnosed after substantial bone loss has occurred, making revision surgery more challenging. The goal of the current study was to identify urinary biomarkers that differentiate total hip replacement patients who eventually develop osteolysis from patients who do not. We used a repository of 24-h urine samples collected prior to surgery and annually thereafter in 26 patients, 16 who developed osteolysis, and 10 who did not. We examined the markers at radiographic diagnosis, annually for 6 years preceding diagnosis, at the first post-operative sampling point, and pre-operatively. Patients in the osteolysis and non-osteolysis groups were matched according to time post-surgery and did not differ in the male:female ratio or age at surgery. Seven candidate biomarkers were measured, including free deoxypyridinoline (DPD), cross-linked N-telopeptides (NTX), interleukin-6 (IL-6), interleukin-8 (IL-8), osteoprotegerin (OPG), α-crosslaps (α-CTX), and β-crosslaps (β-CTX). As an individual biomarker, DPD demonstrated the highest ability to predict osteolysis, with an area under the curve (AUC) in Receiver Operating Characteristic (ROC) analyses of 0.844 at 6 years prior to diagnosis. A panel of α-CTX and IL-6 was able to identify at-risk patients with an AUC of 0.941 or greater at all post-operative time points and an AUC of 1.000 pre-operatively. The results demonstrate the potential of using non-invasive biomarkers to identify patients at risk for peri-implant osteolysis long before the emergence of radiographic signs. Further, the high accuracy of the pre-operative biomarker levels demonstrates the potential importance of pre-existing, patient-specific factors driving subsequent osteolysis. Study Design © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:2754-2761, 2018.
Collapse
Affiliation(s)
- Ryan D. Ross
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL 60612,Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL 60612
| | - Youping Deng
- Department of Complementary & Integrative Medicine, University of Hawaii John A. Burns School of Medicine, Honolulu, Hawaii 96813, USA
| | - Rui Fang
- Department of Complementary & Integrative Medicine, University of Hawaii John A. Burns School of Medicine, Honolulu, Hawaii 96813, USA
| | - Nicholas B. Frisch
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL 60612
| | - Joshua J. Jacobs
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL 60612
| | - D. Rick Sumner
- Department of Cell & Molecular Medicine, Rush University Medical Center, Chicago, IL 60612,Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL 60612
| |
Collapse
|
7
|
Gilbert TJ, Anoushiravani AA, Sayeed Z, Chambers MC, El-Othmani MM, Saleh KJ. Osteolysis Complicating Total Knee Arthroplasty. JBJS Rev 2018; 4:01874474-201607000-00001. [PMID: 27509327 DOI: 10.2106/jbjs.rvw.15.00081] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
Osteolysis is a process mounted by the host immune system that relies on several variables, including patient-related factors, type of insert material, modes of wear, and implant design. Imaging techniques such as radiography, computed tomography (CT) scans, magnetic resonance imaging (MRI), and tomosynthesis aid in diagnosing osteolysis. Surgical options for the treatment of osteolysis include the insertion of bone grafts, bone cement, and prosthetic augmentation. Although no approved pharmacological therapies for the specific treatment of osteolysis exist, the use of bisphosphonates and statins decreases the risk of osteolysis.
Collapse
Affiliation(s)
- Theodore J Gilbert
- Division of Orthopaedics and Rehabilitation, Department of Surgery, Southern Illinois University School of Medicine, Springfield, Illinois
| | | | | | | | | | | |
Collapse
|
8
|
Polyethylene particles inserted over calvarium induce cancellous bone loss in femur in female mice. Bone Rep 2018; 9:84-92. [PMID: 30094298 PMCID: PMC6073052 DOI: 10.1016/j.bonr.2018.07.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/22/2018] [Revised: 06/13/2018] [Accepted: 07/02/2018] [Indexed: 12/29/2022] Open
Abstract
Focal bone resorption (osteolysis) induced by wear particles contributes to long-term orthopedic joint failure. However, the impact of focal osteolysis on remote skeletal sites has received less attention. The goal of this study was to determine the effects of polyethylene particles placed over calvaria on representative axial and appendicular skeletal sites in female mice. Because recent work has identified housing temperature as an important biological variable in mice, response to particle treatment was measured in animals housed at room (22 °C) and thermoneutral (32 °C) temperature. Osteolysis was evident in skeletal tissue adjacent to particle insertion. In addition, cancellous bone loss was observed in distal femur metaphysis. The bone loss was associated with lower osteoblast-lined perimeter and lower mineralizing perimeter in distal femur, lower osteocalcin gene expression in tibia, and lower serum osteocalcin, suggesting the response was due, at least in part, to reduced bone formation. Mild cold stress induced by sub-thermoneutral housing resulted in cancellous bone loss in distal femur and lumbar vertebra but did not influence skeletal response to particles. In summary, the results indicate that focal inflammation induced by polyethylene particles has the potential to result in systemic bone loss. This is significant because bone loss is a risk factor for fracture. Wear particles contribute to orthopedic joint failure by promoting focal inflammation- mediated osteolysis. Here we investigated effects of polyethylene particles placed over calvaria on remote skeletal sites in female mice. Particles placed over calvaria resulted in focal inflammation and cancellous bone loss in distal femur metaphysis. Lower osteoblast-lined perimeter suggests reduced bone formation contributed to bone loss in distal femur. Our results suggest focal inflammation induced by polyethylene particles has the potential to result in systemic bone loss.
Collapse
|
9
|
Jin Y, Chen S, Li N, Liu Y, Cheng G, Zhang C, Wang S, Zhang J. Defect-related luminescent bur-like hydroxyapatite microspheres induced apoptosis of MC3T3-E1 cells by lysosomal and mitochondrial pathways. SCIENCE CHINA-LIFE SCIENCES 2018; 61:464-475. [PMID: 29623549 DOI: 10.1007/s11427-017-9258-3] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2017] [Accepted: 12/20/2017] [Indexed: 12/27/2022]
Abstract
When orthopedic joints coated by hydroxyapatite (HA) were implanted in the human body, they release wear debris into the surrounding tissues. The generation and accumulation of wear particles will induce aseptic loosening. However, the potential bioeffect and mechanism of HA-coated orthopedic implants on bone cells are poorly understood. In this study, defect-related luminescent bur-like hydroxyapatite (BHA) microspheres with the average diameter of 7-9 μm which are comparable to that of the wear-debris particles from aseptically loosened HA implants or HA debris have been synthesized by hydrothermal synthesis and the MC3T3-E1 cells were set as a cells model to study the potential bioeffect and mechanism of BHA microspheres. The studies demonstrated that BHA microspheres could be taken into MC3T3-E1 cells via endocytosis involved in micropinocytosis- and clathrin-mediated endocytosis process, and exert cytotoxicity effect. BHA microspheres could induce the cell apoptosis by intracellular production of reactive oxygen species (ROS), which led to not only an increase in the permeability of lysosome and release of cathepsins B, but also mitochondrial dysfunction and DNA damage. Our results provide novel evidence to elucidate their toxicity mechanisms and might be helpful for more reasonable applications of HA-based orthopaedic implants in the future.
Collapse
Affiliation(s)
- Yi Jin
- College of Chemistry & Environmental Science, Chemical Biology Key Laboratory of Hebei Province, Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of the Ministry of Education, Hebei University, Baoding, 071002, China
- Medical College of Hebei University, Baoding, 071000, China
| | - Shizhu Chen
- College of Chemistry & Environmental Science, Chemical Biology Key Laboratory of Hebei Province, Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of the Ministry of Education, Hebei University, Baoding, 071002, China
| | - Nan Li
- College of Chemistry & Environmental Science, Chemical Biology Key Laboratory of Hebei Province, Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of the Ministry of Education, Hebei University, Baoding, 071002, China
| | - Yajing Liu
- College of Chemistry & Environmental Science, Chemical Biology Key Laboratory of Hebei Province, Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of the Ministry of Education, Hebei University, Baoding, 071002, China
| | - Gong Cheng
- College of Chemistry & Environmental Science, Chemical Biology Key Laboratory of Hebei Province, Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of the Ministry of Education, Hebei University, Baoding, 071002, China
| | - Cuimiao Zhang
- College of Chemistry & Environmental Science, Chemical Biology Key Laboratory of Hebei Province, Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of the Ministry of Education, Hebei University, Baoding, 071002, China
| | - Shuxiang Wang
- College of Chemistry & Environmental Science, Chemical Biology Key Laboratory of Hebei Province, Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of the Ministry of Education, Hebei University, Baoding, 071002, China.
| | - Jinchao Zhang
- College of Chemistry & Environmental Science, Chemical Biology Key Laboratory of Hebei Province, Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of the Ministry of Education, Hebei University, Baoding, 071002, China.
| |
Collapse
|
10
|
Moran MM, Wilson BM, Ross RD, Virdi AS, Sumner DR. Arthrotomy-based preclinical models of particle-induced osteolysis: A systematic review. J Orthop Res 2017; 35:2595-2605. [PMID: 28548682 PMCID: PMC5702596 DOI: 10.1002/jor.23619] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/16/2016] [Accepted: 05/24/2017] [Indexed: 02/04/2023]
Abstract
We completed a systematic literature review of in vivo animal models that use arthrotomy-based methods to study particle-induced peri-implant osteolysis. The purpose of the review was to characterize the models developed to date, to determine the questions addressed, to assess scientific rigor and transparency, and to identify gaps in knowledge. We probed three literature databases (Medline, Embase, and Scopus) and found 77 manuscripts that fit the search parameters. In the most recent 10 years, researchers mainly used rat and mouse models, whereas in the previous 20 years, large animal, canine, and rabbit models were more common. The studies have demonstrated several pathophysiology pathways, including macrophage migration, particle phagocytosis, increased local production of cytokines and lysosomal enzymes, elevated bone resorption, and suppressed bone formation. The effect of variation in particle characteristics and concentration received limited attention with somewhat mixed findings. Particle contamination by endotoxin was shown to exacerbate peri-implant osteolysis. The possibility of early diagnosis was demonstrated through imaging and biomarker approaches. Several studies showed that both local and systemic delivery of bisphosphonates inhibits the development of particle-induced osteolysis. Other methods of inhibiting osteolysis include the use of anabolic agents and altering the implant design. Few studies examined non-surgical rescue of loosened implants, with conflicting results with alendronate. We found that the manuscripts often lacked the methodological detail now advocated by the ARRIVE guidelines, suggesting that improvement in reporting would be useful to maximize rigor and transparency. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2595-2605, 2017.
Collapse
Affiliation(s)
- Meghan M. Moran
- Department of Anatomy and Cell Biology, Rush University Medical Center
| | | | - Ryan D. Ross
- Department of Anatomy and Cell Biology, Rush University Medical Center
| | - Amarjit S. Virdi
- Department of Anatomy and Cell Biology, Rush University Medical Center
| | | |
Collapse
|
11
|
PTH[1-34] improves the effects of core decompression in early-stage steroid-associated osteonecrosis model by enhancing bone repair and revascularization. PLoS One 2017; 12:e0178781. [PMID: 28562696 PMCID: PMC5451136 DOI: 10.1371/journal.pone.0178781] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2016] [Accepted: 05/18/2017] [Indexed: 12/31/2022] Open
Abstract
Steroid-associated osteonecrosis (SAON) might induce bone collapse and subsequently lead to joint arthroplasty. Core decompression (CD) is regarded as an effective therapy for early-stage SAON, but the prognosis is unsatisfactory due to incomplete bone repair. Parathyroid hormone[1–34] (PTH[1–34]) has demonstrated positive efficacy in promoting bone formation. We therefore evaluated the effects of PTH on improving the effects of CD in Early-Stage SAON. Distal femoral CD was performed two weeks after osteonecrosis induction or vehicle injection, with ten of the ON-induced rabbits being subjected to six-week PTH[1–34] treatment and the others, including ON-induced and non-induced rabbits, being treated with vehicle. MRI confirmed that intermittent PTH administration improved SAON after CD therapy. Micro-CT showed increased bone formation within the tunnel. Bone repair was enhanced with decreased empty osteocyte lacunae and necrosis foci area, resulting in enhanced peak load and stiffness of the tunnel. Additionally, PTH enlarged the mean diameter of vessels in the marrow and increased the number of vessels within the tunnels, as well as elevated the expression of BMP-2, RUNX2, IGF-1, bFGF and VEGF, together with serum OCN and VEGF levels. Therefore, PTH[1–34] enhances the efficacy of CD on osteogenesis and neovascularization, thus promoting bone and blood vessels repair in the SAON model.
Collapse
|
12
|
Ye C, Zhang W, Jiang S, Yu Y, Zhou X, Zhu L, Xue D, He R. Platelet-derived growth factor-BB attenuates titanium-particle-induced osteolysis in vivo. Growth Factors 2016; 34:177-186. [PMID: 27776448 DOI: 10.1080/08977194.2016.1240680] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
Inflammation and osteoclastogenesis play critical roles in wear-particle-induced periprosthetic osteolysis (WPO). Platelet-derived growth factor-BB (PDGF-BB) could promote osteogenesis and inhibit inflammatory response. The aim of this study was to investigate the impact of PDGF-BB on WPO. Mice were divided into four groups, namely, sham, vehicle, low-, and high-dose PDGF-BB groups. Mice in the rhPDGF-BB groups were treated with PDGF-BB at 0.25 or 1 mg/ml/kg/day. Mice in the sham and vehicle groups received PBS daily. Two weeks after surgery, calvariae were harvested. Immunohistochemical analysis and μ-CT showed that PDGF-BB significantly reduced osteoclast formation and bone resorption. ELISA showed that rhPDGF-BB decreased the secretion of TNF-α, IL-1β, and IL-6. Western blotting revealed that rhPDGF-BB stimulated the expression of osteocalcin and osteoprotegerin. Furthermore, more VEGF and CD31 proteins were observed due to PDGF-BB by immunofluorescence. In conclusion, these findings suggest that rhPDGF-BB represents a potential treatment for WPO.
Collapse
Affiliation(s)
- Chenyi Ye
- a Department of Orthopedic Surgery , the Second Affiliated Hospital, School of Medicine, Zhejiang University , Hangzhou , Zhejiang , China
| | - Wei Zhang
- a Department of Orthopedic Surgery , the Second Affiliated Hospital, School of Medicine, Zhejiang University , Hangzhou , Zhejiang , China
| | - Shuai Jiang
- a Department of Orthopedic Surgery , the Second Affiliated Hospital, School of Medicine, Zhejiang University , Hangzhou , Zhejiang , China
| | - Yuanbin Yu
- a Department of Orthopedic Surgery , the Second Affiliated Hospital, School of Medicine, Zhejiang University , Hangzhou , Zhejiang , China
| | - Xiaoyu Zhou
- a Department of Orthopedic Surgery , the Second Affiliated Hospital, School of Medicine, Zhejiang University , Hangzhou , Zhejiang , China
| | - Ling Zhu
- a Department of Orthopedic Surgery , the Second Affiliated Hospital, School of Medicine, Zhejiang University , Hangzhou , Zhejiang , China
| | - Deting Xue
- a Department of Orthopedic Surgery , the Second Affiliated Hospital, School of Medicine, Zhejiang University , Hangzhou , Zhejiang , China
| | - Rongxin He
- a Department of Orthopedic Surgery , the Second Affiliated Hospital, School of Medicine, Zhejiang University , Hangzhou , Zhejiang , China
| |
Collapse
|
13
|
Intramembranous bone regeneration and implant placement using mechanical femoral marrow ablation: rodent models. BONEKEY REPORTS 2016; 5:837. [PMID: 27648259 DOI: 10.1038/bonekey.2016.61] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2016] [Accepted: 07/19/2016] [Indexed: 12/16/2022]
Abstract
In this paper, we provide a detailed protocol for a model of long bone mechanical marrow ablation in the rodent, including surgical procedure, anesthesia, and pre- and post-operative care. In addition, frequently used experimental end points are briefly discussed. This model was developed to study intramembranous bone regeneration following surgical disruption of the marrow contents of long bones. In this model, the timing of the appearance of bone formation and remodeling is well-characterized and therefore the model is well-suited to evaluate the in vivo effects of various agents which influence these processes. When biomaterials such as tissue engineering scaffolds or metal implants are placed in the medullary cavity after marrow ablation, end points relevant to tissue engineering and implant fixation can also be analyzed. By sharing a detailed protocol, we hope to improve inter-laboratory reproducibility.
Collapse
|
14
|
Wang J, Tao Y, Ping Z, Zhang W, Hu X, Wang Y, Wang L, Shi J, Wu X, Yang H, Xu Y, Geng D. Icariin attenuates titanium-particle inhibition of bone formation by activating the Wnt/β-catenin signaling pathway in vivo and in vitro. Sci Rep 2016; 6:23827. [PMID: 27029606 PMCID: PMC4814911 DOI: 10.1038/srep23827] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2016] [Accepted: 03/14/2016] [Indexed: 12/20/2022] Open
Abstract
Wear-debris-induced periprosthetic osteolysis (PIO) is a common clinical condition following total joint arthroplasty, which can cause implant instability and failure. The host response to wear debris promotes bone resorption and impairs bone formation. We previously demonstrated that icariin suppressed wear-debris-induced osteoclastogenesis and attenuated particle-induced osteolysis in vivo. Whether icariin promotes bone formation in a wear-debris-induced osteolytic site remains unclear. Here, we demonstrated that icariin significantly attenuated titanium-particle inhibition of osteogenic differentiation of mesenchymal stem cells (MSCs). Additionally, icariin increased bone mass and decreased bone loss in titanium-particle-induced osteolytic sites. Mechanistically, icariin inhibited decreased β-catenin stability induced by titanium particles in vivo and in vitro. To confirm icariin mediated its bone-protective effects via the Wnt/β-catenin signaling pathway, we demonstrated that ICG-001, a selective Wnt/β-catenin inhibitor, attenuated the effects of icariin on MSC mineralization in vitro and bone formation in vivo. Therefore, icariin could induce osteogenic differentiation of MSCs and promote new bone formation at a titanium-particle-induced osteolytic site via activation of the Wnt/β-catenin signaling pathway. These results further support the protective effects of icariin on particle-induced bone loss and provide novel mechanistic insights into the recognized bone-anabolic effects of icariin and an evidence-based rationale for its use in PIO treatment.
Collapse
Affiliation(s)
- Junhua Wang
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, 188, shi zi Road, Suzhou, 215006, China
| | - Yunxia Tao
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, 188, shi zi Road, Suzhou, 215006, China
| | - Zichuan Ping
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, 188, shi zi Road, Suzhou, 215006, China
| | - Wen Zhang
- Orthopedic Institute, Soochow University, 708, ren min Road, Suzhou, 215006, China
| | - Xuanyang Hu
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, 188, shi zi Road, Suzhou, 215006, China
| | - Yijun Wang
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, 188, shi zi Road, Suzhou, 215006, China
| | - Liangliang Wang
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, 188, shi zi Road, Suzhou, 215006, China
| | - Jiawei Shi
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, 188, shi zi Road, Suzhou, 215006, China
| | - Xiexing Wu
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, 188, shi zi Road, Suzhou, 215006, China
| | - Huilin Yang
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, 188, shi zi Road, Suzhou, 215006, China
| | - Yaozeng Xu
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, 188, shi zi Road, Suzhou, 215006, China
| | - Dechun Geng
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, 188, shi zi Road, Suzhou, 215006, China
| |
Collapse
|
15
|
Kolatat K, Perino G, Wilner G, Kaplowitz E, Ricciardi BF, Boettner F, Westrich GH, Jerabek SA, Goldring SR, Purdue PE. Adverse local tissue reaction (ALTR) associated with corrosion products in metal-on-metal and dual modular neck total hip replacements is associated with upregulation of interferon gamma-mediated chemokine signaling. J Orthop Res 2015; 33:1487-97. [PMID: 25940887 DOI: 10.1002/jor.22916] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/14/2015] [Accepted: 03/27/2015] [Indexed: 02/04/2023]
Abstract
Adverse local tissue reactions (ALTR) associated with tribocorrosion following total hip arthroplasty (THA) have become a significant clinical concern in recent years. In particular, implants featuring metal-on-metal bearing surfaces and modular femoral stems have been reported to result in elevated rates of ALTR. These tribocorrosion-related tissue reactions are characterized by marked necrosis and lymphocytic infiltration, which contrasts sharply with the macrophagic and foreign body giant cell inflammation associated with polyethylene wear particle induced peri-implant osteolysis. In this study, we characterize tribocorrosion-associated ALTR at a molecular level. Gene expression profiling of peri-implant tissue around failing implants identifies upregulation of numerous inflammatory mediators in ALTR, including several interferon gamma inducible factors, most notably the chemokines MIG/CXCL9 and IP-10/CXCL10. This expression profile is distinct from that associated with polyethylene wear induced osteolysis, which is characterized by induction of markers of alternative macrophage activation, such as chitotriosidase (CHIT-1). Importantly, MIG/CXCL9 and IP-10/CXCL10 are also elevated at the protein level in the synovial fluid and, albeit more moderately, the serum, of ALTR patients, raising the possibility that these factors may serve as circulating biomarkers for the early detection of ALTR in at-risk patients.
Collapse
|
16
|
Geng D, Wu J, Shao H, Zhu S, Wang Y, Zhang W, Ping Z, Hu X, Zhu X, Xu Y, Yang H. Pharmaceutical inhibition of glycogen synthetase kinase 3 beta suppresses wear debris-induced osteolysis. Biomaterials 2015; 69:12-21. [PMID: 26275858 DOI: 10.1016/j.biomaterials.2015.07.061] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2015] [Revised: 07/30/2015] [Accepted: 07/31/2015] [Indexed: 11/19/2022]
Abstract
Aseptic loosening is associated with the development of wear debris-induced peri-implant osteolytic bone disease caused by an increased osteoclastic bone resorption and decreased osteoblastic bone formation. However, no effective measures for the prevention and treatment of peri-implant osteolysis currently exist. The aim of this study was to determine whether lithium chloride (LiCl), a selective inhibitor of glycogen synthetase kinase 3 beta (GSK-3β), mitigates wear debris-induced osteolysis in a murine calvarial model of osteolysis. GSK-3β is activated by titanium (Ti) particles, and implantation of Ti particles on the calvarial surface in C57BL/6 mice resulted in osteolysis caused by an increase in the number of osteoclasts and a decrease in the number of osteoblasts. Mice implanted with Ti particles were gavage-fed LiCl (50 or 200 mg kg(-1)d(-1)), 6 days per week for 2 weeks. The LiCl treatment significantly inhibited GSK-3β activity and increased β-catenin and axin-2 expression in a dose-dependent manner, dramatically mitigating the Ti particle-induced suppression of osteoblast numbers and the expression of bone formation markers. Finally, we demonstrated that inhibition of GSK-3β suppresses osteoclast differentiation and reduces the severity of Ti particle-induced osteolysis. The results of this study indicate that Ti particle-induced osteolysis is partly dependent on GSK-3β and, therefore, the canonical Wnt signaling pathway. This suggests that selective inhibitors of GSK-3β such as LiCl may help prevent and treat wear debris-induced osteolysis.
Collapse
Affiliation(s)
- Dechun Geng
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, People's Republic of China.
| | - Jian Wu
- Department of Rheumatology, The First Affiliated Hospital of Soochow University, People's Republic of China
| | - Hongguo Shao
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, People's Republic of China
| | - Shijun Zhu
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, People's Republic of China
| | - Yijun Wang
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, People's Republic of China
| | - Wen Zhang
- Orthopedic Institute, Soochow University, People's Republic of China
| | - Zichuan Ping
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, People's Republic of China
| | - Xuanyang Hu
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, People's Republic of China
| | - Xuesong Zhu
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, People's Republic of China
| | - Yaozeng Xu
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, People's Republic of China.
| | - Huilin Yang
- Department of Orthopedics, The First Affiliated Hospital of Soochow University, People's Republic of China.
| |
Collapse
|
17
|
Sumner DR, Ross R, Purdue E. Are there biological markers for wear or corrosion? A systematic review. Clin Orthop Relat Res 2014; 472:3728-39. [PMID: 24668073 PMCID: PMC4397751 DOI: 10.1007/s11999-014-3580-3] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
Abstract
BACKGROUND Identification of biomarkers associated with wear and tribocorrosion in joint arthroplasty would be helpful to enhance early detection of aseptic loosening and/or osteolysis and to improve understanding of disease progression. There have been several new reports since the last systematic review (which covered research through mid-2008) justifying a new assessment. QUESTIONS/PURPOSES We sought to determine which biomarkers have the most promise for early diagnosis and monitoring of aseptic loosening and/or osteolysis related to wear or corrosion in total joint arthroplasty. METHODS We performed a systematic review using MEDLINE and EMBASE databases, covering the period through December 2013, and identified 1050 articles. We restricted the definition of biomarker to biomolecules and imaging parameters useful for diagnosis and monitoring of disease progression, only including articles in English. We chose 65 articles for full review, including 44 from the original search and 21 from subsequent hand searches. We used the 22 articles in which patients with total joint arthroplasty who had aseptic loosening and/or periimplant osteolysis unrelated to sepsis had been compared with patients with total joint arthroplasty with stable implants. There were 90 comparisons of these two patient populations involving 35 different biomarkers. RESULTS Diagnostic accuracy was assessed in nine of the 90 comparisons with the highest accuracy found for tartrate-resistant acid phosphatase 5b (0.96), although a separate comparison for this biomarker found a lower accuracy (0.76). Accuracy of > 0.80 was also found for crosslinked n-telopeptide of type I collagen, osteoprotegerin, and deoxypyridinoline. The most studied markers, tumor necrosis factor-α and interleukin-1β, were found to differ in the affected and control groups in < 30% of the comparisons. Thirty of the 35 biomarkers were studied in four or fewer separate comparisons with nearly half of the biomarkers (17) studied in only one comparison. Many of the comparisons were not able to eliminate a number of confounding variables, and there was only one prospective study. CONCLUSIONS Currently, there are no validated biomarkers for early diagnosis and monitoring of the biological sequelae of wear or tribocorrosion, although there are some promising leads, including markers of bone turnover.
Collapse
Affiliation(s)
- D. Rick Sumner
- Department of Anatomy and Cell Biology, Rush University Medical Center, 600 South Paulina, Suite 507, Chicago, IL 60612 USA ,Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL USA
| | - Ryan Ross
- Department of Anatomy and Cell Biology, Rush University Medical Center, 600 South Paulina, Suite 507, Chicago, IL 60612 USA
| | - Ed Purdue
- Hospital for Special Surgery, New York, NY USA
| |
Collapse
|
18
|
Maier GS, Eberhardt C, Strauch M, Kafchitsas K, Kurth AA. Is tartrate-resistant acid phosphatase 5b a potent bio-marker for late stage aseptic implant loosening? INTERNATIONAL ORTHOPAEDICS 2014; 38:2597-600. [DOI: 10.1007/s00264-014-2471-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2014] [Accepted: 07/14/2014] [Indexed: 10/25/2022]
|