1
|
Shen Q, Wu W, Chiew M, Ji Y, Woods JG, Okell TW. Ultra-high temporal resolution 4D angiography using arterial spin labeling with subspace reconstruction. Magn Reson Med 2025; 93:1924-1941. [PMID: 40063716 PMCID: PMC11893029 DOI: 10.1002/mrm.30407] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2024] [Revised: 10/23/2024] [Accepted: 12/04/2024] [Indexed: 03/14/2025]
Abstract
PURPOSE To achieve ultra-high temporal resolution non-contrast 4D angiography with improved spatiotemporal fidelity. METHODS Continuous data acquisition using 3D golden-angle sampling following an arterial spin labeling preparation allows for flexibly reconstructing 4D dynamic angiograms at arbitrary temporal resolutions. However, k-space data is often temporally "binned" before image reconstruction, negatively affecting spatiotemporal fidelity and limiting temporal resolution. In this work, a subspace was extracted by linearly compressing a dictionary constructed from simulated curves of an angiographic kinetic model. The subspace was used to represent and reconstruct the voxelwise signal timecourse at the same temporal resolution as the data acquisition without temporal binning. Physiological parameters were estimated from the resulting images using a Bayesian fitting approach. A group of eight healthy subjects were scanned and the in vivo results reconstructed by different methods were compared. Because of the difficulty of obtaining ground truth 4D angiograms with ultra-high temporal resolution, the in vivo results were cross-validated with numerical simulations. RESULTS The proposed method enables 4D time-resolved angiography with much higher temporal resolution (14.7 ms) than previously reported (˜50 ms) while maintaining high spatial resolution (1.1 mm isotropic). Blood flow dynamics were depicted in greater detail, thin vessel visibility was improved, and the estimated physiological parameters also exhibited more realistic spatial patterns with the proposed method. CONCLUSION Incorporating a subspace compressed kinetic model into the reconstruction of 4D ASL angiograms notably improved the temporal resolution and spatiotemporal fidelity, which was subsequently beneficial for accurate physiological modeling.
Collapse
Affiliation(s)
- Qijia Shen
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical NeurosciencesUniversity of Oxford
OxfordUK
| | - Wenchuan Wu
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical NeurosciencesUniversity of Oxford
OxfordUK
| | - Mark Chiew
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical NeurosciencesUniversity of Oxford
OxfordUK
- Physical SciencesSunnybrook Research InstituteTorontoOntarioCanada
- Department of Medical BiophysicsUniversity of TorontoTorontoOntarioCanada
| | - Yang Ji
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical NeurosciencesUniversity of Oxford
OxfordUK
| | - Joseph G. Woods
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical NeurosciencesUniversity of Oxford
OxfordUK
| | - Thomas W. Okell
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical NeurosciencesUniversity of Oxford
OxfordUK
| |
Collapse
|
2
|
Rastegar Jooybari F, Huynh C, Portnoy S, Voutsas J, Balmer-Minnes D, Saprungruang A, Yoo SJ, Lam CZ, Macgowan CK. Highly accelerated 4D flow MRI with respiratory compensation and cardiac view sharing: a cross-sectional study of flow in the great vessels of pediatric congenital heart disease. Pediatr Radiol 2025:10.1007/s00247-025-06226-1. [PMID: 40186653 DOI: 10.1007/s00247-025-06226-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2024] [Revised: 03/12/2025] [Accepted: 03/15/2025] [Indexed: 04/07/2025]
Abstract
BACKGROUND Conventional four-dimensional (4D) flow magnetic resonance imaging (MRI) is limited by long scan times, particularly in pediatric congenital heart disease (CHD) patients. OBJECTIVE This study evaluates accelerated 4D flow MRI incorporating respiratory compensation and cardiac view sharing in healthy adults and pediatric CHD patients. MATERIALS AND METHODS Subjects underwent 5-min free-breathing protocol with a three-dimensional (3D) radial trajectory and compressed sensing reconstruction. The 4D flow MRI reconstruction pipeline was improved by respiratory soft-gating and cardiac view sharing. Flow in major thoracic vessels was compared with two-dimensional (2D) phase contrast MRI, the reference standard. RESULTS Fourteen pediatric CHD patients (median age: 13 years (interquartile range (IQR): 5)) and four healthy adult volunteers (median age: 26 years (IQR: 3)) were recruited. Soft-gating improved diaphragm sharpness and reduced respiratory-induced blur (image quality scores: healthy: 46.1 soft-gated vs. 47.2 non-gated; CHD: 47.8 soft-gated vs. 48.2 non-gated). View sharing reduced undersampling artifacts and enhanced the signal-to-noise ratio (SNR, healthy: +9.9%; CHD: +3.8%). In healthy adults, correlations with 2D phase contrast MRI were strong for mean flow (R2=0.94, slope=0.94±0.12, root mean square error (RMSE)=6.4 ml/s; bias=1.1±6.4 ml/s, P=0.45) and peak flow (R2=0.9, slope=0.86±0.13, RMSE=40.9 ml/s; bias=21.3±44.7 ml/s, P=0.04). Similarly, CHD patients showed a strong correlation for mean flow (R2=0.88, slope=0.93±0.09, RMSE=8.3 ml/s) and peak flow (R2=0.97, slope=0.98±0.03, RMSE=25.9 ml/s). Internal consistency for 4D flow MRI in CHD cases showed mean percent differences of 6.1% Main pulmonary artery=Left pulmonary artery+Right pulmonary artery and 6.5% Ascending aorta=Descending aorta+Superior vena cava. CONCLUSION The accelerated 4D flow MRI method provides robust flow quantification and visualization in pediatric CHD patients, strongly correlating with 2D phase contrast MRI and completing scans in 5 min for clinical use.
Collapse
Affiliation(s)
- Fatemeh Rastegar Jooybari
- University of Toronto, 27 King's College Cir, Toronto, ON, M5S 1A1, Canada.
- Hospital for Sick Children, Toronto, Canada.
| | | | | | | | | | | | | | | | - Christopher K Macgowan
- University of Toronto, 27 King's College Cir, Toronto, ON, M5S 1A1, Canada
- Hospital for Sick Children, Toronto, Canada
| |
Collapse
|
3
|
Shen Q, Wu W, Chiew M, Ji Y, Woods JG, Okell TW. Efficient 3D cone trajectory design for improved combined angiographic and perfusion imaging using arterial spin labeling. Magn Reson Med 2024; 92:1568-1583. [PMID: 38767321 DOI: 10.1002/mrm.30149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Revised: 03/25/2024] [Accepted: 04/22/2024] [Indexed: 05/22/2024]
Abstract
PURPOSE To improve the spatial resolution and repeatability of a non-contrast MRI technique for simultaneous time resolved 3D angiography and perfusion imaging by developing an efficient 3D cone trajectory design. METHODS A novel parameterized 3D cone trajectory design incorporating the 3D golden angle was integrated into 4D combined angiography and perfusion using radial imaging and arterial spin labeling (CAPRIA) to achieve higher spatial resolution and sampling efficiency for both dynamic angiography and perfusion imaging with flexible spatiotemporal resolution. Numerical simulations and physical phantom scanning were used to optimize the cone design. Eight healthy volunteers were scanned to compare the original radial trajectory in 4D CAPRIA with our newly designed cone trajectory. A locally low rank reconstruction method was used to leverage the complementary k-space sampling across time. RESULTS The improved sampling in the periphery of k-space obtained with the optimized 3D cone trajectory resulted in improved spatial resolution compared with the radial trajectory in phantom scans. Improved vessel sharpness and perfusion visualization were also achieved in vivo. Less dephasing was observed in the angiograms because of the short TE of our cone trajectory and the improved k-space sampling efficiency also resulted in higher repeatability compared to the original radial approach. CONCLUSION The proposed 3D cone trajectory combined with 3D golden angle ordering resulted in improved spatial resolution and image quality for both angiography and perfusion imaging and could potentially benefit other applications that require an efficient sampling scheme with flexible spatial and temporal resolution.
Collapse
Affiliation(s)
- Qijia Shen
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
| | - Wenchuan Wu
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
| | - Mark Chiew
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
- Physical Sciences, Sunnybrook Research Institute, Toronto, Ontario, Canada
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario, Canada
| | - Yang Ji
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
| | - Joseph G Woods
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
| | - Thomas W Okell
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
| |
Collapse
|
4
|
Lee S, Schmit BD, Kurpad SN, Budde MD. Cervical spinal cord angiography and vessel-selective perfusion imaging in the rat. NMR IN BIOMEDICINE 2024; 37:e5115. [PMID: 38355219 PMCID: PMC11078600 DOI: 10.1002/nbm.5115] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 01/04/2024] [Accepted: 01/15/2024] [Indexed: 02/16/2024]
Abstract
Arterial spin labeling (ASL) has been widely used to evaluate arterial blood and perfusion dynamics, particularly in the brain, but its application to the spinal cord has been limited. The purpose of this study was to optimize vessel-selective pseudocontinuous arterial spin labeling (pCASL) for angiographic and perfusion imaging of the rat cervical spinal cord. A pCASL preparation module was combined with a train of gradient echoes for dynamic angiography. The effects of the echo train flip angle, label duration, and a Cartesian or radial readout were compared to examine their effects on visualizing the segmental arteries and anterior spinal artery (ASA) that supply the spinal cord. Lastly, vessel-selective encoding with either vessel-encoded pCASL (VE-pCASL) or super-selective pCASL (SS-pCASL) were compared. Vascular territory maps were obtained with VE-pCASL perfusion imaging of the spinal cord, and the interanimal variability was evaluated. The results demonstrated that longer label durations (200 ms) resulted in greater signal-to-noise ratio in the vertebral arteries, improved the conspicuity of the ASA, and produced better quality maps of blood arrival times. Cartesian and radial readouts demonstrated similar image quality. Both VE-pCASL and SS-pCASL adequately labeled the right or left vertebral arteries, which revealed the interanimal variability in the segmental artery with variations in their location, number, and laterality. VE-pCASL also demonstrated unique interanimal variations in spinal cord perfusion with a right-sided dominance across the six animals. Vessel-selective pCASL successfully achieved visualization of the arterial inflow dynamics and corresponding perfusion territories of the spinal cord. These methodological developments provide unique insights into the interanimal variations in the arterial anatomy and dynamics of spinal cord perfusion.
Collapse
Affiliation(s)
- Seongtaek Lee
- Joint Department of Biomedical Engineering, Marquette University & Medical College of Wisconsin, Milwaukee, WI
- Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, WI
| | - Brian D Schmit
- Joint Department of Biomedical Engineering, Marquette University & Medical College of Wisconsin, Milwaukee, WI
| | - Shekar N Kurpad
- Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, WI
- Clement J. Zablocki Veterans Affairs Medical Center, Milwaukee, WI
| | - Matthew D Budde
- Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, WI
- Clement J. Zablocki Veterans Affairs Medical Center, Milwaukee, WI
| |
Collapse
|
5
|
Jagadeesan B, Tariq F, Nada A, Bhatti IA, Masood K, Siddiq F. Principles Behind 4D Time-Resolved MRA/Dynamic MRA in Neurovascular Imaging. Semin Roentgenol 2024; 59:191-202. [PMID: 38880517 DOI: 10.1053/j.ro.2024.02.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2024] [Accepted: 02/28/2024] [Indexed: 06/18/2024]
Affiliation(s)
- Bharathi Jagadeesan
- Departments of Radiology, Neurology and Neurosurgery, University of Minnesota, Minneapolis, MN.
| | - Farzana Tariq
- Departments of Neurosurgery and Radiology, University of Missouri, Columbia, MO
| | - Ayman Nada
- Departments of Neurosurgery and Radiology, University of Missouri, Columbia, MO
| | - Ibrahim A Bhatti
- Departments of Neurosurgery and Radiology, University of Missouri, Columbia, MO
| | - Kamran Masood
- Departments of Radiology, Neurology and Neurosurgery, University of Minnesota, Minneapolis, MN
| | - Farhan Siddiq
- Departments of Neurosurgery and Radiology, University of Missouri, Columbia, MO
| |
Collapse
|
6
|
Okell TW, Chiew M. Optimization of 4D combined angiography and perfusion using radial imaging and arterial spin labeling. Magn Reson Med 2023; 89:1853-1870. [PMID: 36533868 PMCID: PMC10952652 DOI: 10.1002/mrm.29558] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Revised: 11/27/2022] [Accepted: 11/28/2022] [Indexed: 12/23/2022]
Abstract
PURPOSE To extend and optimize a non-contrast MRI technique to obtain whole head 4D (time-resolved 3D) qualitative angiographic and perfusion images from a single scan. METHODS 4D combined angiography and perfusion using radial imaging and arterial spin labeling (CAPRIA) uses pseudocontinuous labeling with a 3D golden ratio ("koosh ball") readout to continuously image the blood water as it travels through the arterial system and exchanges into the tissue. High spatial/temporal resolution angiograms and low spatial/temporal resolution perfusion images can be flexibly reconstructed from the same raw k-space data. Constant and variable flip angle (CFA and VFA, respectively) excitation schedules were optimized through simulations and tested in healthy volunteers. A conventional sensitivity encoding (SENSE) reconstruction was compared against a locally low rank (LLR) reconstruction, which leverages spatiotemporal correlations. Comparison was also made with time-matched time-of-flight angiography and multi-delay EPI perfusion images. Differences in image quality were assessed through split-scan repeatability. RESULTS The optimized VFA schedule (2-9°) resulted in a significant (p < 0.001) improvement in image quality (up to 84% vs. CFA), particularly for the lower SNR perfusion images. The LLR reconstruction provided effective denoising without biasing the signal timecourses, significantly improving angiographic and perfusion image quality and repeatability (up to 143%, p < 0.001). 4D CAPRIA performed well compared with time-of-flight angiography and had better perfusion signal repeatability than the EPI-based approach (p < 0.001). CONCLUSION 4D CAPRIA optimized using a VFA schedule and LLR reconstruction can yield high quality whole head 4D angiograms and perfusion images from a single scan.
Collapse
Affiliation(s)
- Thomas W. Okell
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical NeurosciencesUniversity of Oxford
OxfordUK
| | - Mark Chiew
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical NeurosciencesUniversity of Oxford
OxfordUK
| |
Collapse
|
7
|
Hong SW, Song HN, Choi JU, Cho HH, Baek IY, Lee JE, Kim YC, Chung D, Chung JW, Bang OY, Kim GM, Park HJ, Liebeskind DS, Seo WK. Automated in-depth cerebral arterial labelling using cerebrovascular vasculature reframing and deep neural networks. Sci Rep 2023; 13:3255. [PMID: 36828857 PMCID: PMC9957982 DOI: 10.1038/s41598-023-30234-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2022] [Accepted: 02/20/2023] [Indexed: 02/26/2023] Open
Abstract
Identifying the cerebral arterial branches is essential for undertaking a computational approach to cerebrovascular imaging. However, the complexity and inter-individual differences involved in this process have not been thoroughly studied. We used machine learning to examine the anatomical profile of the cerebral arterial tree. The method is less sensitive to inter-subject and cohort-wise anatomical variations and exhibits robust performance with an unprecedented in-depth vessel range. We applied machine learning algorithms to disease-free healthy control subjects (n = 42), patients with stroke with intracranial atherosclerosis (ICAS) (n = 46), and patients with stroke mixed with the existing controls (n = 69). We trained and tested 70% and 30% of each study cohort, respectively, incorporating spatial coordinates and geometric vessel feature vectors. Cerebral arterial images were analyzed based on the 'segmentation-stacking' method using magnetic resonance angiography. We precisely classified the cerebral arteries across the exhaustive scope of vessel components using advanced geometric characterization, redefinition of vessel unit conception, and post-processing algorithms. We verified that the neural network ensemble, with multiple joint models as the combined predictor, classified all vessel component types independent of inter-subject variations in cerebral arterial anatomy. The validity of the categorization performance of the model was tested, considering the control, ICAS, and control-blended stroke cohorts, using the area under the receiver operating characteristic (ROC) curve and precision-recall curve. The classification accuracy rarely fell outside each image's 90-99% scope, independent of cohort-dependent cerebrovascular structural variations. The classification ensemble was calibrated with high overall area rates under the ROC curve of 0.99-1.00 [0.97-1.00] in the test set across various study cohorts. Identifying an all-inclusive range of vessel components across controls, ICAS, and stroke patients, the accuracy rates of the prediction were: internal carotid arteries, 91-100%; middle cerebral arteries, 82-98%; anterior cerebral arteries, 88-100%; posterior cerebral arteries, 87-100%; and collections of superior, anterior inferior, and posterior inferior cerebellar arteries, 90-99% in the chunk-level classification. Using a voting algorithm on the queued classified vessel factors and anatomically post-processing the automatically classified results intensified quantitative prediction performance. We employed stochastic clustering and deep neural network ensembles. Ma-chine intelligence-assisted prediction of vessel structure allowed us to personalize quantitative predictions of various types of cerebral arterial structures, contributing to precise and efficient decisions regarding the cerebrovascular disease.
Collapse
Affiliation(s)
- Suk-Woo Hong
- Department of Neurology and Stroke Center, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, 06351, Korea
- Program in Brain Science, College of Natural Sciences, Seoul National University, Seoul, 08826, Korea
| | - Ha-Na Song
- Department of Neurology and Stroke Center, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, 06351, Korea
| | - Jong-Un Choi
- Department of Neurology and Stroke Center, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, 06351, Korea
- Department of Digital Health, Samsung Advanced Institute for Health Sciences and Technology, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Irwon-dong, Gangnam-gu, Seoul, 06351, Korea
| | - Hwan-Ho Cho
- Department of Medical Artificial Intelligence, Konyang University, Daejeon, Korea
| | - In-Young Baek
- Department of Neurology and Stroke Center, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, 06351, Korea
| | - Ji-Eun Lee
- Department of Neurology and Stroke Center, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, 06351, Korea
| | - Yoon-Chul Kim
- Division of Digital Healthcare, Yonsei University Mirae Campus, Wonju, 26493, Korea
| | - Darda Chung
- Department of Neurology and Stroke Center, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, 06351, Korea
| | - Jong-Won Chung
- Department of Neurology and Stroke Center, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, 06351, Korea
| | - Oh-Young Bang
- Department of Neurology and Stroke Center, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, 06351, Korea
| | - Gyeong-Moon Kim
- Department of Neurology and Stroke Center, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, 06351, Korea
| | - Hyun-Jin Park
- Department of Electronic Electrical and Computer Engineering, Sungkyunkwan University, Suwon, 16419, Korea
- Center for Neuroscience Imaging Research, Institute for Basic Science (IBS), Suwon, 16419, Korea
| | - David S Liebeskind
- Department of Neurology and Comprehensive Stroke Center, UCLA, Los Angeles, CA, USA
| | - Woo-Keun Seo
- Department of Neurology and Stroke Center, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, 06351, Korea.
- Department of Digital Health, Samsung Advanced Institute for Health Sciences and Technology, Sungkyunkwan University School of Medicine, 81 Irwon-ro, Irwon-dong, Gangnam-gu, Seoul, 06351, Korea.
| |
Collapse
|
8
|
Hernandez‐Garcia L, Aramendía‐Vidaurreta V, Bolar DS, Dai W, Fernández‐Seara MA, Guo J, Madhuranthakam AJ, Mutsaerts H, Petr J, Qin Q, Schollenberger J, Suzuki Y, Taso M, Thomas DL, van Osch MJP, Woods J, Zhao MY, Yan L, Wang Z, Zhao L, Okell TW. Recent Technical Developments in ASL: A Review of the State of the Art. Magn Reson Med 2022; 88:2021-2042. [PMID: 35983963 PMCID: PMC9420802 DOI: 10.1002/mrm.29381] [Citation(s) in RCA: 41] [Impact Index Per Article: 13.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2022] [Revised: 05/31/2022] [Accepted: 06/18/2022] [Indexed: 12/11/2022]
Abstract
This review article provides an overview of a range of recent technical developments in advanced arterial spin labeling (ASL) methods that have been developed or adopted by the community since the publication of a previous ASL consensus paper by Alsop et al. It is part of a series of review/recommendation papers from the International Society for Magnetic Resonance in Medicine Perfusion Study Group. Here, we focus on advancements in readouts and trajectories, image reconstruction, noise reduction, partial volume correction, quantification of nonperfusion parameters, fMRI, fingerprinting, vessel selective ASL, angiography, deep learning, and ultrahigh field ASL. We aim to provide a high level of understanding of these new approaches and some guidance for their implementation, with the goal of facilitating the adoption of such advances by research groups and by MRI vendors. Topics outside the scope of this article that are reviewed at length in separate articles include velocity selective ASL, multiple-timepoint ASL, body ASL, and clinical ASL recommendations.
Collapse
Affiliation(s)
| | | | - Divya S. Bolar
- Center for Functional Magnetic Resonance Imaging, Department of RadiologyUniversity of California at San DiegoSan DiegoCaliforniaUSA
| | - Weiying Dai
- Department of Computer ScienceState University of New York at BinghamtonBinghamtonNYUSA
| | | | - Jia Guo
- Department of BioengineeringUniversity of California RiversideRiversideCaliforniaUSA
| | | | - Henk Mutsaerts
- Department of Radiology & Nuclear MedicineAmsterdam University Medical Center, Amsterdam NeuroscienceAmsterdamThe Netherlands
| | - Jan Petr
- Helmholtz‐Zentrum Dresden‐RossendorfInstitute of Radiopharmaceutical Cancer ResearchDresdenGermany
| | - Qin Qin
- The Russell H. Morgan Department of Radiology and Radiological ScienceJohns Hopkins UniversityBaltimoreMarylandUSA
| | | | - Yuriko Suzuki
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical NeurosciencesUniversity of OxfordOxfordUnited Kingdom
| | - Manuel Taso
- Division of MRI research, RadiologyBeth Israel Deaconess Medical Center and Harvard Medical SchoolBostonMassachusettsUSA
| | - David L. Thomas
- Department of Brain Repair and RehabilitationUCL Queen Square Institute of NeurologyLondonUnited Kingdom
| | - Matthias J. P. van Osch
- C.J. Gorter Center for high field MRI, Department of RadiologyLeiden University Medical CenterLeidenThe Netherlands
| | - Joseph Woods
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical NeurosciencesUniversity of OxfordOxfordUnited Kingdom
- Department of RadiologyUniversity of CaliforniaLa JollaCaliforniaUSA
| | - Moss Y. Zhao
- Department of RadiologyStanford UniversityStanfordCaliforniaUSA
| | - Lirong Yan
- Department of Radiology, Feinberg School of MedicineNorthwestern UniversityChicagoIllinoisUSA
| | - Ze Wang
- Department of Diagnostic Radiology and Nuclear MedicineUniversity of Maryland School of MedicineBaltimoreMarylandUSA
| | - Li Zhao
- Key Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering & Instrument ScienceZhejiang UniversityZhejiangPeople's Republic of China
| | - Thomas W. Okell
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical NeurosciencesUniversity of OxfordOxfordUnited Kingdom
| |
Collapse
|
9
|
Feng L, Liu F, Soultanidis G, Liu C, Benkert T, Block KT, Fayad ZA, Yang Y. Magnetization-prepared GRASP MRI for rapid 3D T1 mapping and fat/water-separated T1 mapping. Magn Reson Med 2021; 86:97-114. [PMID: 33580909 PMCID: PMC8197608 DOI: 10.1002/mrm.28679] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Revised: 12/18/2020] [Accepted: 12/22/2020] [Indexed: 12/22/2022]
Abstract
PURPOSE This study aimed to (i) develop Magnetization-Prepared Golden-angle RAdial Sparse Parallel (MP-GRASP) MRI using a stack-of-stars trajectory for rapid free-breathing T1 mapping and (ii) extend MP-GRASP to multi-echo acquisition (MP-Dixon-GRASP) for fat/water-separated (water-specific) T1 mapping. METHODS An adiabatic non-selective 180° inversion-recovery pulse was added to a gradient-echo-based golden-angle stack-of-stars sequence for magnetization-prepared 3D single-echo or 3D multi-echo acquisition. In combination with subspace-based GRASP-Pro reconstruction, the sequence allows for standard T1 mapping (MP-GRASP) or fat/water-separated T1 mapping (MP-Dixon-GRASP), respectively. The accuracy of T1 mapping using MP-GRASP was evaluated in a phantom and volunteers (brain and liver) against clinically accepted reference methods. The repeatability of T1 estimation was also assessed in the phantom and volunteers. The performance of MP-Dixon-GRASP for water-specific T1 mapping was evaluated in a fat/water phantom and volunteers (brain and liver). RESULTS ROI-based mean T1 values are correlated between the references and MP-GRASP in the phantom (R2 = 1.0), brain (R2 = 0.96), and liver (R2 = 0.73). MP-GRASP achieved good repeatability of T1 estimation in the phantom (R2 = 1.0), brain (R2 = 0.99), and liver (R2 = 0.82). Water-specific T1 is different from in-phase and out-of-phase composite T1 (composite T1 when fat and water signal are mixed in phase or out of phase) both in the phantom and volunteers. CONCLUSION This work demonstrated the initial performance of MP-GRASP and MP-Dixon-GRASP MRI for rapid 3D T1 mapping and 3D fat/water-separated T1 mapping in the brain (without motion) and in the liver (during free breathing). With fat/water-separated T1 estimation, MP-Dixon-GRASP could be potentially useful for imaging patients with fatty-liver diseases.
Collapse
Affiliation(s)
- Li Feng
- Biomedical Engineering and Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Fang Liu
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Georgios Soultanidis
- Biomedical Engineering and Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Chenyu Liu
- Biomedical Engineering and Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Thomas Benkert
- MR Application Development, Siemens Healthcare GmbH, Erlangen, Germany
| | - Kai Tobias Block
- MR Application Development, Siemens Healthcare GmbH, Erlangen, Germany
- Center for Advanced Imaging Innovation and Research (CAIR), New York University School of Medicine, New York, NY, USA
| | - Zahi A. Fayad
- Biomedical Engineering and Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Yang Yang
- Biomedical Engineering and Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| |
Collapse
|
10
|
van der Plas MCE, Schmid S, Versluis MJ, Okell TW, van Osch MJP. Time-encoded golden angle radial arterial spin labeling: Simultaneous acquisition of angiography and perfusion data. NMR IN BIOMEDICINE 2021; 34:e4519. [PMID: 33939218 PMCID: PMC8243971 DOI: 10.1002/nbm.4519] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Revised: 02/27/2021] [Accepted: 03/16/2021] [Indexed: 06/12/2023]
Abstract
The objective of the current study was to combine a time-encoded pseudocontinuous arterial spin labeling (te-pCASL) scheme with a golden angle radial readout for simultaneous acquisition of angiography and perfusion images from one single dataset, both in a highly flexible single-slice approach as well as within a multislice setting. A te-pCASL preparation and the golden angle radial readout were both used as a temporal resolution tool to retrospectively choose the temporal window for the reconstruction of both angiography and perfusion images from a single-slice dataset. The temporal window could be chosen retrospectively and adjusted to the hemodynamics of the volunteer on the scanner for the single-slice dataset. Angiographic images were reconstructed at a minimum temporal resolution of 69 ms. For the perfusion phase, only the densely sampled center of k-space was included in the reconstruction. For a multislice acquisition, the golden angle radial readout allowed reconstruction of images with different spatial resolutions to provide angiographic and perfusion information over 10 slices. The te-pCASL preparation was used as the only source for dynamic information. The multislice acquisition shows the ability of the golden angle radial readout to display the inflow of the labeled blood into the arteries as well as the perfusion in the tissue with full brain coverage. By combining a te-pCASL preparation with a golden angle radial readout, single-slice high temporal resolution angiography and good quality perfusion images were reconstructed in a flexible manner from a single dataset. Optimizing the golden angle radial readout for reconstructions at multiple spatial resolutions allows for multislice acquisition.
Collapse
Affiliation(s)
- Merlijn C. E. van der Plas
- C. J. Gorter Center for High Field MRI, Department of RadiologyLeiden University Medical CenterLeidenthe Netherlands
- Leiden Institute of Brain and Cognition (LIBC)Leiden University Medical CenterLeidenthe Netherlands
| | - Sophie Schmid
- C. J. Gorter Center for High Field MRI, Department of RadiologyLeiden University Medical CenterLeidenthe Netherlands
- Leiden Institute of Brain and Cognition (LIBC)Leiden University Medical CenterLeidenthe Netherlands
| | | | - Thomas W. Okell
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical NeurosciencesUniversity of OxfordOxfordUK
| | - Matthias J. P. van Osch
- C. J. Gorter Center for High Field MRI, Department of RadiologyLeiden University Medical CenterLeidenthe Netherlands
- Leiden Institute of Brain and Cognition (LIBC)Leiden University Medical CenterLeidenthe Netherlands
| |
Collapse
|
11
|
Shao X, Yan L, Ma SJ, Wang K, Wang DJJ. High-Resolution Neurovascular Imaging at 7T: Arterial Spin Labeling Perfusion, 4-Dimensional MR Angiography, and Black Blood MR Imaging. Magn Reson Imaging Clin N Am 2021; 29:53-65. [PMID: 33237015 PMCID: PMC7694883 DOI: 10.1016/j.mric.2020.09.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
Ultrahigh field offers increased resolution and contrast for neurovascular imaging. Arterial spin labeling methods benefit from an increased intrinsic signal-to-noise ratio of MR imaging signal and a prolonged tracer half-life at ultrahigh field, allowing the visualization of layer-dependent microvascular perfusion. Arterial spin labeling-based time-resolved 4-dimensional MR angiography at 7T provides a detailed depiction of the vascular architecture and dynamic blood flow pattern with high spatial and temporal resolutions. High-resolution black blood MR imaging at 7T allows detailed characterization of small perforating arteries such as lenticulostriate arteries. All techniques benefit from advances in parallel radiofrequency transmission technologies at ultrahigh field.
Collapse
Affiliation(s)
- Xingfeng Shao
- Laboratory of FMRI Technology (LOFT), USC Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, 2025 Zonal Avenue, Los Angeles, CA 90033, USA
| | - Lirong Yan
- Laboratory of FMRI Technology (LOFT), USC Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, 2025 Zonal Avenue, Los Angeles, CA 90033, USA; Department of Neurology, Keck School of Medicine, University of Southern California, 2025 Zonal Avenue, Los Angeles, CA 90033, USA
| | - Samantha J Ma
- Laboratory of FMRI Technology (LOFT), USC Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, 2025 Zonal Avenue, Los Angeles, CA 90033, USA; Siemens Healthcare, Los Angeles, CA, USA
| | - Kai Wang
- Laboratory of FMRI Technology (LOFT), USC Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, 2025 Zonal Avenue, Los Angeles, CA 90033, USA
| | - Danny J J Wang
- Laboratory of FMRI Technology (LOFT), USC Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, 2025 Zonal Avenue, Los Angeles, CA 90033, USA; Department of Neurology, Keck School of Medicine, University of Southern California, 2025 Zonal Avenue, Los Angeles, CA 90033, USA.
| |
Collapse
|
12
|
Heidari Pahlavian S, Geri O, Russin J, Ma SJ, Amar A, Wang DJJ, Ben Bashat D, Yan L. Semiautomatic cerebrovascular territory mapping based on dynamic ASL MR angiography without vessel-encoded labeling. Magn Reson Med 2020; 85:2735-2746. [PMID: 33347641 DOI: 10.1002/mrm.28623] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Revised: 11/07/2020] [Accepted: 11/09/2020] [Indexed: 11/11/2022]
Abstract
PURPOSE Characterizing vessel territories can provide crucial information for evaluation of cerebrovascular disorders. In this study, we present a novel postprocessing pipeline for vascular territorial imaging of cerebral arteries based on a noncontrast enhanced time-resolved 4D magnetic resonance angiography (MRA). METHODS Eight healthy participants, 1 Moyamoya patient, and 1 arteriovenous malformations patient were recruited. Territorial segmentation and relative blood flow rate calculations of cerebral arteries including left and right middle cerebral arteries and left and right posterior cerebral arteries were carried out based on the 4D MRA-derived arterial arrival time maps of intracranial vessels. RESULTS Among healthy young subjects, the average relative blood flow rate values corresponding to left and right middle cerebral arteries and left and right posterior cerebral arteries were 35.9 ± 5.9%, 32.9 ± 7.5%, 15.4 ± 3.8%, and 15.9 ± 2.5%, respectively. Excellent agreement was observed between relative blood flow rate values obtained from the proposed 4D MRA-based method and reference 2D phase contrast MRI. Abnormal cerebral circulations were visualized and quantified on both patients using the developed technique. CONCLUSION The vascular territorial imaging technique developed in this study allowed for the generation of territorial maps with user-defined level of details within a clinically feasible scan time, and as such may provide useful information to assess cerebral circulation balance in different pathologies.
Collapse
Affiliation(s)
- Soroush Heidari Pahlavian
- USC Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA.,Department of Neurology, University of Southern California, Los Angeles, CA, USA
| | | | - Jonathan Russin
- Department of Neurosurgery, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Samantha J Ma
- USC Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA.,Department of Neurology, University of Southern California, Los Angeles, CA, USA
| | - Arun Amar
- Department of Neurosurgery, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA
| | - Danny J J Wang
- USC Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA.,Department of Neurology, University of Southern California, Los Angeles, CA, USA
| | - Dafna Ben Bashat
- Sagol Brain Institute, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine & Sagol School of Neuroscience, Tel Aviv University, Tel Aviv, Israel
| | - Lirong Yan
- USC Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, CA, USA.,Department of Neurology, University of Southern California, Los Angeles, CA, USA
| |
Collapse
|
13
|
Chen Z, Zhou Z, Qi H, Chen H, Chu B, Hatsukami TS, Yuan C, Balu N. A novel sequence for simultaneous measurement of whole-brain static and dynamic MRA, intracranial vessel wall image, and T 1 -weighted structural brain MRI. Magn Reson Med 2020; 85:316-325. [PMID: 32738091 DOI: 10.1002/mrm.28431] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2020] [Revised: 06/08/2020] [Accepted: 06/23/2020] [Indexed: 11/08/2022]
Abstract
PURPOSE To propose a highly time-efficient imaging technique named improved simultaneous noncontrast angiography and intraplaque hemorrhage (iSNAP) for simultaneous assessment of lumen, vessel wall, and blood flow in intracranial arteries. METHODS iSNAP consists of pulsed arterial spin labeling preparations and 3D golden angle radial acquisition. Images were reconstructed by k-space weighted image contrast (KWIC) method with optimized data-sharing strategies. Dynamic MRA for blood flow assessment was obtained from iSNAP by reconstruction at multiple inversion times and image subtraction, static MRA by both image subtraction approach and phase-sensitive inversion recovery technique, and vessel wall images by both reconstruction at zero-crossing time-point of blood and phase-sensitive inversion recovery. A T1 -weighted brain MRI was also reconstructed from iSNAP. Preliminary comparison of iSNAP against the dedicated dynamic MRA sequence 4D-TRANCE, MRA/vessel wall imaging sequence SNAP, and vessel wall imaging sequence T1 -weighted VISTA was performed in healthy volunteers and patients. RESULTS iSNAP has whole-brain coverage and takes ~6.5 min. The dedicated reconstruction strategies are feasible for each iSNAP image contrast and beneficial for image SNR. iSNAP-dynamic MRA yields similar dynamic flow information as 4D-TRANCE and allows more flexible temporal resolution. The 2 types of iSNAP static MRA images complement each other in characterizing both proximal large arteries and distal small arteries. Depiction of vessel wall lesions in iSNAP vessel wall images is better than SNAP and may be similar to T1 -weighted VISTA, although the images are slightly blurred. CONCLUSION iSNAP provides a time-efficient evaluation of intracranial arteries and may have great potential for comprehensive assessment of intracranial vascular conditions using a single sequence.
Collapse
Affiliation(s)
- Zhensen Chen
- Vascular Imaging Lab and BioMolecular Imaging Center, Department of Radiology, University of Washington, Seattle, Washington, USA
| | - Zechen Zhou
- Philips Research North America, Cambridge, Massachusetts, USA
| | - Haikun Qi
- School of Biomedical Engineering & Imaging Science, King's College London, London, United Kingdom
| | - Huijun Chen
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, Tsinghua University School of Medicine, Beijing, People's Republic of China
| | - Baocheng Chu
- Vascular Imaging Lab and BioMolecular Imaging Center, Department of Radiology, University of Washington, Seattle, Washington, USA
| | - Thomas S Hatsukami
- Department of Surgery, University of Washington, Seattle, Washington, USA
| | - Chun Yuan
- Vascular Imaging Lab and BioMolecular Imaging Center, Department of Radiology, University of Washington, Seattle, Washington, USA
| | - Niranjan Balu
- Vascular Imaging Lab and BioMolecular Imaging Center, Department of Radiology, University of Washington, Seattle, Washington, USA
| |
Collapse
|
14
|
Kitoh Y, Miyati T, Tamaru N, Fujinaga Y. [Examination of Gd-EOB-DTPA Liver Dynamic Contrast-enhanced MRI Using Radial VIBE with k-space Weighted Image Contrast Method]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2020; 76:270-277. [PMID: 32201417 DOI: 10.6009/jjrt.2020_jsrt_76.3.270] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Dynamic contrast-enhanced magnetic imaging (DCE-MRI) is a useful method for detection and diagnosis of liver lesions. However, DCE-MRI using Gd-EOB-DTPA has some problems with arterial phase images. Radial volumetric imaging breath-holding examination (r-VIBE) with k-space weighted image contrast reconstruction (KWIC), which is a modification of Cartesian VIBE (c-VIBE), is a new 3D-gradient echo sequence with a number of advantages compared with c-VIBE, including lower motion sensitivity. This study was performed to evaluate image contrast, blurring, and temporal phase division effects of r-VIBE in comparison with c-VIBE. Image contrast using diluted Gd-EOB-DTPA aqueous solution showed no significant difference between r-VIBE and c-VIBE. Imaging was performed with r-VIBE and c-VIBE during injection of a Gd-EOB-DTPA solution into a serpentine tube. r-VIBE showed a smaller half-width of the signal intensity profile of the tube and less image artifacts by blurring when compared to c-VIBE. The arrival times and durations of the maximum signal strengths of r-VIBE and c-VIBE images during injection of Gd-EOB-DTPA solution into the tube were almost identical. r-VIBE improved the temporal resolution without degradation of liver DCE-MRI using Gd-EOB-DTPA.
Collapse
Affiliation(s)
| | - Tosiaki Miyati
- Division of Health Sciences, Graduate School of Medical Sciences, Kanazawa University
| | | | - Yasunari Fujinaga
- Radiology Division, Shinshu University Hospital
- Department of Radiology, Shinshu University School of Medicine
| |
Collapse
|
15
|
Suzuki Y, Fujima N, van Osch MJP. Intracranial 3D and 4D MR Angiography Using Arterial Spin Labeling: Technical Considerations. Magn Reson Med Sci 2019; 19:294-309. [PMID: 31761840 PMCID: PMC7809141 DOI: 10.2463/mrms.rev.2019-0096] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
In the 1980’s some of the earliest studies of arterial spin labeling (ASL) MRI have demonstrated its ability to generate MR angiography (MRA) images. Thanks to many technical improvements, ASL has been successfully moving its position from the realm of research into the clinical area, albeit more known as perfusion imaging than as MRA. For MRA imaging, other techniques such as time-of-flight, phase contrast MRA and contrast-enhanced (CE) MRA are more popular choices for clinical applications. In the last decade, however, ASL-MRA has been experiencing a remarkable revival, especially because of its non-invasive nature, i.e. the fact that it does not rely on the use of contrast agent. Very importantly, there are additional benefits of using ASL for MRA. For example, its higher flexibility to achieve both high spatial and temporal resolution than CE dynamic MRA, and the capability of vessel specific visualization, in which the vascular tree arising from a selected artery can be exclusively visualized. In this article, the implementation and recent developments of ASL-based MRA are discussed; not only focusing on the basic sequences based upon pulsed ASL or pseudo-continuous ASL, but also including more recent labeling approaches, such as vessel-selective labeling, velocity-selective ASL, vessel-encoded ASL and time-encoded ASL. Although these ASL techniques have been already utilized in perfusion imaging and their usefulness has been suggested by many studies, some additional considerations should be made when employing them for MRA, since there is something more than the difference of the spatial resolution of the readout sequence. Moreover, extensive discussion is included on what readout sequence to use, especially by highlighting how to achieve high spatial resolution while keeping scan-time reasonable such that the ASL-MRA sequence can easily be included into a clinical examination.
Collapse
Affiliation(s)
- Yuriko Suzuki
- Institute of Biomedical Engineering, University of Oxford
| | - Noriyuki Fujima
- Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital
| | | |
Collapse
|
16
|
The advantages of radial trajectories for vessel-selective dynamic angiography with arterial spin labeling. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2019; 32:643-653. [PMID: 31422519 PMCID: PMC6825642 DOI: 10.1007/s10334-019-00771-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Revised: 07/10/2019] [Accepted: 07/27/2019] [Indexed: 10/31/2022]
Abstract
OBJECTIVES To demonstrate the advantages of radial k-space trajectories over conventional Cartesian approaches for accelerating the acquisition of vessel-selective arterial spin labeling (ASL) dynamic angiograms, which are conventionally time consuming to acquire. MATERIALS AND METHODS Vessel-encoded pseudocontinuous ASL was combined with time-resolved balanced steady-state free precession (bSSFP) and spoiled gradient echo (SPGR) readouts to obtain dynamic vessel-selective angiograms arising from the four main brain-feeding arteries. Dynamic 2D protocols with acquisition times of one minute or less were achieved through radial undersampling or a Cartesian parallel imaging approach. For whole-brain dynamic 3D imaging, magnetic field inhomogeneity and the high acceleration factors required rule out the use of bSSFP and Cartesian trajectories, so the feasibility of acquiring 3D radial SPGR angiograms was tested. RESULTS The improved SNR efficiency of bSSFP over SPGR was confirmed for 2D dynamic imaging. Radial trajectories had considerable advantages over a Cartesian approach, including a factor of two improvements in the measured SNR (p < 0.00001, N = 6), improved distal vessel delineation and the lack of a need for calibration data. The 3D radial approach produced good quality angiograms with negligible artifacts despite the high acceleration factor (R = 13). CONCLUSION Radial trajectories outperform conventional Cartesian techniques for accelerated vessel-selective ASL dynamic angiography.
Collapse
|
17
|
Xiong Y, Zhang Z, He L, Ma Y, Han H, Zhao X, Guo H. Intracranial simultaneous noncontrast angiography and intraplaque hemorrhage (SNAP) MRA: Analyzation, optimization, and extension for dynamic MRA. Magn Reson Med 2019; 82:1646-1659. [DOI: 10.1002/mrm.27855] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2019] [Revised: 05/20/2019] [Accepted: 05/20/2019] [Indexed: 01/15/2023]
Affiliation(s)
- Yuhui Xiong
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine Tsinghua University Beijing People's Republic of China
| | - Zhe Zhang
- China National Clinical Research Center for Neurological Diseases Beijing Tiantan Hospital, Capital Medical University Beijing People's Republic of China
| | - Le He
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine Tsinghua University Beijing People's Republic of China
| | - Yu Ma
- Tsinghua University Yuquan Hospital Beijing People's Republic of China
| | - Hualu Han
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine Tsinghua University Beijing People's Republic of China
| | - Xihai Zhao
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine Tsinghua University Beijing People's Republic of China
| | - Hua Guo
- Center for Biomedical Imaging Research, Department of Biomedical Engineering, School of Medicine Tsinghua University Beijing People's Republic of China
| |
Collapse
|
18
|
Shao X, Zhao Z, Russin J, Amar A, Sanossian N, Wang DJ, Yan L. Quantification of intracranial arterial blood flow using noncontrast enhanced 4D dynamic MR angiography. Magn Reson Med 2019; 82:449-459. [PMID: 30847971 DOI: 10.1002/mrm.27712] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2018] [Revised: 01/16/2019] [Accepted: 02/05/2019] [Indexed: 01/27/2023]
Abstract
PURPOSE Noncontrast enhanced dynamic magnetic resonance angiography delineates the pattern of dynamic blood flow of the cerebral vasculature. A model-free solution was proposed to quantify arterial blood flow (aBF) by using the monotonic property of the residual function. THEORY AND METHODS Analytical simulations and in-vivo studies were performed to evaluate the performance of the proposed method by comparing the aBF values generated from the proposed and conventional singular value decomposition methods. The aBF values were compared with blood flow velocity measured by 2D phase contrast MRI, and compared between balanced steady-state free precession-based radial and spoiled GRE-based Cartesian acquisitions. Hemodynamic parametric maps were generated in 1 patient with arteriovenous malformation. RESULTS The proposed method generates reliable aBF measurement at different signal-to-noise ratio levels, whereas overestimation/underestimation of aBF was observed when a high/low threshold was applied in the singular value decomposition method. Average aBF in large vascular branches was 214.4 and 214.5 mL/mL/min with radial and Cartesian acquisitions, respectively. Significant correlations were found between aBF and blood flow velocity measured by phase contrast MRI (P = 0.0008), and between Cartesian and radial acquisitions (P < 0.0001). Altered hemodynamics were observed at the lesion site of the arteriovenous malformation patient. CONCLUSION A robust analytical solution was proposed for quantifying aBF. This model-free method is robust to noise, and its clinical value in the diagnosis of cerebrovascular disorders awaits further evaluation.
Collapse
Affiliation(s)
- Xingfeng Shao
- Laboratory of FMRI Technology (LOFT), Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, California
| | - Ziwei Zhao
- Laboratory of FMRI Technology (LOFT), Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, California
| | - Jonathan Russin
- Center for Neurorestoration, Department of Neurological Surgery, Keck School of Medicine, University of Southern California, Los Angeles, California
| | - Arun Amar
- Center for Neurorestoration, Department of Neurological Surgery, Keck School of Medicine, University of Southern California, Los Angeles, California
| | - Nerses Sanossian
- Department of Neurology, Keck School of Medicine, University of Southern California, Los Angeles, California
| | - Danny Jj Wang
- Laboratory of FMRI Technology (LOFT), Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, California.,Department of Neurology, Keck School of Medicine, University of Southern California, Los Angeles, California
| | - Lirong Yan
- Laboratory of FMRI Technology (LOFT), Mark & Mary Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, California.,Department of Neurology, Keck School of Medicine, University of Southern California, Los Angeles, California
| |
Collapse
|
19
|
Okell TW. Combined angiography and perfusion using radial imaging and arterial spin labeling. Magn Reson Med 2019; 81:182-194. [PMID: 30024066 PMCID: PMC6282709 DOI: 10.1002/mrm.27366] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2017] [Revised: 03/28/2018] [Accepted: 04/25/2018] [Indexed: 11/24/2022]
Abstract
PURPOSE To demonstrate the feasibility of a novel noninvasive MRI technique for the comprehensive evaluation of blood flow to the brain: combined angiography and perfusion using radial imaging and arterial spin labeling (CAPRIA). METHODS In the CAPRIA pulse sequence, blood labeled with a pseudocontinuous arterial spin labeling pulse train is continuously imaged as it flows through the arterial tree and into the brain tissue using a golden ratio radial readout. From a single raw data set, this flexible imaging approach allows the reconstruction of both high spatial/temporal resolution angiographic images with a high undersampling factor and low spatial/temporal resolution perfusion images with a low undersampling factor. The sparse and high SNR nature of angiographic images ensures that radial undersampling artifacts are relatively benign, even when using a simple regridding image reconstruction. Pulse sequence parameters were optimized through sampling efficiency calculations and the numerical evaluation of modified pseudocontinuous arterial spin labeling signal models. A comparison was made against conventional pseudocontinuous arterial spin labeling angiographic and perfusion acquisitions. RESULTS 2D CAPRIA data in healthy volunteers demonstrated the feasibility of this approach, with good vessel visualization in the angiographic images and clear tissue perfusion signal when reconstructed at 108-ms and 252-ms temporal resolution, respectively. Images were qualitatively similar to those from conventional acquisitions, but CAPRIA had significantly higher SNR efficiency (48% improvement on average, P = 0.02). CONCLUSION The CAPRIA technique shows potential for the efficient evaluation of both macrovascular blood flow and tissue perfusion within a single scan, with potential applications in a range of cerebrovascular diseases.
Collapse
Affiliation(s)
- Thomas W. Okell
- Wellcome Centre for Integrative Neuroimaging, FMRIB, Nuffield Department of Clinical NeurosciencesUniversity of OxfordOxfordUnited Kingdom
| |
Collapse
|
20
|
Zhang J, Feng L, Otazo R, Kim SG. Rapid dynamic contrast-enhanced MRI for small animals at 7T using 3D ultra-short echo time and golden-angle radial sparse parallel MRI. Magn Reson Med 2019; 81:140-152. [PMID: 30058079 PMCID: PMC6258350 DOI: 10.1002/mrm.27357] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2018] [Revised: 04/02/2018] [Accepted: 04/22/2018] [Indexed: 01/18/2023]
Abstract
PURPOSE To develop a rapid dynamic contrast-enhanced MRI method with high spatial and temporal resolution for small-animal imaging at 7 Tesla. METHODS An ultra-short echo time (UTE) pulse sequence using a 3D golden-angle radial sampling was implemented to achieve isotropic spatial resolution with flexible temporal resolution. Continuously acquired radial spokes were grouped into subsets for image reconstruction using a multicoil compressed sensing approach (Golden-angle RAdial Sparse Parallel; GRASP). The proposed 3D-UTE-GRASP method with high temporal and spatial resolutions was tested using 7 mice with GL261 intracranial glioma models. RESULTS Iterative reconstruction with different temporal resolutions and regularization factors λ showed that, in all cases, the cost function decreased to less than 2.5% of its starting value within 20 iterations. The difference between the time-intensity curves of 3D-UTE-GRASP and nonuniform fast Fourier transform (NUFFT) images was minimal when λ was 1% of the maximum signal intensity of the initial NUFFT images. The 3D isotropic images were used to generate pharmacokinetic parameter maps to show the detailed images of the tumor characteristics in 3D and also to show longitudinal changes during tumor growth. CONCLUSION This feasibility study demonstrated that the proposed 3D-UTE-GRASP method can be used for effective measurement of the 3D spatial heterogeneity of tumor pharmacokinetic parameters.
Collapse
Affiliation(s)
- Jin Zhang
- Center for Biomedical Imaging (CBI), Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University School of Medicine, New York, NY, United States
| | - Li Feng
- Center for Biomedical Imaging (CBI), Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University School of Medicine, New York, NY, United States
| | - Ricardo Otazo
- Center for Biomedical Imaging (CBI), Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University School of Medicine, New York, NY, United States
| | - Sungheon Gene Kim
- Center for Biomedical Imaging (CBI), Center for Advanced Imaging Innovation and Research (CAIR), Department of Radiology, New York University School of Medicine, New York, NY, United States
| |
Collapse
|
21
|
Cruz G, Schneider T, Bruijnen T, Gaspar AS, Botnar RM, Prieto C. Accelerated magnetic resonance fingerprinting using soft-weighted key-hole (MRF-SOHO). PLoS One 2018; 13:e0201808. [PMID: 30092033 PMCID: PMC6084944 DOI: 10.1371/journal.pone.0201808] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2018] [Accepted: 07/23/2018] [Indexed: 11/28/2022] Open
Abstract
Object To develop a novel approach for highly accelerated Magnetic Resonance Fingerprinting (MRF) acquisition. Materials and methods The proposed method combines parallel imaging, soft-gating and key-hole approaches to highly accelerate MRF acquisition. Slowly varying flip angles (FA), commonly used during MRF acquisition, lead to a smooth change in the signal contrast of consecutive time-point images. This assumption enables sharing of high frequency data between different time-points, similar to what is done in some dynamic MR imaging methods such as key-hole. The proposed approach exploits this information using a SOft-weighted key-HOle (MRF-SOHO) reconstruction to achieve high acceleration factors and/or increased resolution without compromising image quality or increasing scan time. MRF-SOHO was validated on a standard T1/T2 phantom and in in-vivo brain acquisitions reconstructing T1, T2 and proton density parametric maps. Results Accelerated MRF-SOHO using less data per time-point and less time-point images enabled a considerable reduction in scan time (up to 4.6x), while obtaining similar T1 and T2 accuracy and precision when compared to zero-filled MRF reconstruction. For the same number of spokes and time-points, the proposed method yielded an enhanced performance in quantifying parameters than the zero-filled MRF reconstruction, which was verified with 2, 1 and 0.7 (sub-millimetre) resolutions. Conclusion The proposed MRF-SOHO enabled a 4.6x scan time reduction for an in-plane spatial resolution of 2x2 mm2 when compared to zero-filled MRF and enabled sub-millimetric (0.7x0.7 mm2) resolution MRF.
Collapse
Affiliation(s)
- Gastao Cruz
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
- * E-mail:
| | | | - Tom Bruijnen
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Andreia S. Gaspar
- Institute for Systems and Robotics / Department of Bioengineering, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal
| | - René M. Botnar
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
- Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Claudia Prieto
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom
- Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile
| |
Collapse
|
22
|
Darçot E, Yerly J, Colotti R, Masci PG, Chaptinel J, Feliciano H, Bianchi V, van Heeswijk RB. Accelerated and high-resolution cardiac T 2 mapping through peripheral k-space sharing. Magn Reson Med 2018; 81:220-233. [PMID: 30058085 DOI: 10.1002/mrm.27374] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2017] [Revised: 04/26/2018] [Accepted: 05/01/2018] [Indexed: 12/15/2022]
Abstract
PURPOSE To develop high-spatial-resolution cardiac T2 mapping that allows for a reduced acquisition time while maintaining its precision. We implemented and optimized a new golden-angle radial T2 mapping technique named SKRATCH (Shared k-space Radial T2 Characterization of the Heart) that shares k-space peripheries of T2 -weighted images while preserving their contrasts. METHODS Six SKRATCH variants (gradient-recalled echo and balanced SSFP, free-breathing and breath-held, with and without a saturation preparation) were implemented, and their precision was compared with a navigator-gated reference technique in phantoms and 22 healthy volunteers at 3 T. The optimal breath-held SKRATCH technique was applied in a small cohort of patients with subacute myocardial infarction. RESULTS The faster free-breathing SKRATCH technique reduced the acquisition time by 52.4%, while maintaining the precision and spatial resolution of the reference technique. Similarly, the most precise and robust breath-held SKRATCH technique demonstrated homogenous T2 values that did not significantly differ from the navigator-gated reference (T2 = 39.9 ± 3.4 ms versus 39.5 ± 3.4 ms, P > .20, respectively). All infarct patients demonstrated a large T2 elevation in the ischemic regions of the myocardium. CONCLUSION The optimized SKRATCH technique enabled the accelerated acquisition of high-spatial-resolution T2 maps, was validated in healthy adult volunteers, and was successfully applied to a small initial group of patients.
Collapse
Affiliation(s)
- Emeline Darçot
- Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Jérôme Yerly
- Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland.,Center for Biomedical Imaging, Lausanne and Geneva, Switzerland
| | - Roberto Colotti
- Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Pier Giorgio Masci
- Center for Cardiac Magnetic Resonance, Cardiology Service, Lausanne University Hospital, Lausanne, Switzerland
| | - Jerome Chaptinel
- Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Helene Feliciano
- Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Veronica Bianchi
- Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Ruud B van Heeswijk
- Department of Radiology, University Hospital and University of Lausanne, Lausanne, Switzerland.,Center for Biomedical Imaging, Lausanne and Geneva, Switzerland
| |
Collapse
|
23
|
Jezzard P, Chappell MA, Okell TW. Arterial spin labeling for the measurement of cerebral perfusion and angiography. J Cereb Blood Flow Metab 2018; 38:603-626. [PMID: 29168667 PMCID: PMC5888859 DOI: 10.1177/0271678x17743240] [Citation(s) in RCA: 73] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/28/2022]
Abstract
Arterial spin labeling (ASL) is an MRI technique that was first proposed a quarter of a century ago. It offers the prospect of non-invasive quantitative measurement of cerebral perfusion, making it potentially very useful for research and clinical studies, particularly where multiple longitudinal measurements are required. However, it has suffered from a number of challenges, including a relatively low signal-to-noise ratio, and a confusing number of sequence variants, thus hindering its clinical uptake. Recently, however, there has been a consensus adoption of an accepted acquisition and analysis framework for ASL, and thus a better penetration onto clinical MRI scanners. Here, we review the basic concepts in ASL and describe the current state-of-the-art acquisition and analysis approaches, and the versatility of the method to perform both quantitative cerebral perfusion measurement, along with quantitative cerebral angiographic measurement.
Collapse
Affiliation(s)
- Peter Jezzard
- 1 Wellcome Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| | | | - Thomas W Okell
- 1 Wellcome Centre for Integrative Neuroimaging, FMRIB Division, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK
| |
Collapse
|
24
|
Cong F, Zhuo Y, Yu S, Zhang X, Miao X, An J, Wang S, Cao Y, Zhang Y, Song HK, Wang DJ, Yan L. Noncontrast-enhanced time-resolved 4D dynamic intracranial MR angiography at 7T: A feasibility study. J Magn Reson Imaging 2017; 48:111-120. [PMID: 29232026 DOI: 10.1002/jmri.25923] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2017] [Accepted: 11/28/2017] [Indexed: 11/05/2022] Open
Abstract
BACKGROUND Arterial spin labeling (ASL) based-noncontrast-enhanced 4D MR angiography (NCE 4D MRA) shows potential in characterizing cerebrovascular hemodynamics in cerebrovascular disorders. Ultrahigh-field theoretically benefits ASL signal with increased inherent signal-to-noise ratio (SNR) and prolonged blood T1 , which may provide improved delineation of vasculature in 4D MRA. PURPOSE To investigate the feasibility of NCE 4D MRA using 3D Cartesian trajectory and stack-of-stars (SOS) golden angle radial trajectory at 7T. STUDY TYPE A prospective study. SUBJECTS Six normal volunteers and eight patients with arteriovenous malformation (AVM). FIELD STRENGTH/SEQUENCE NCE 4D MRA with Cartesian and radial trajectories were performed at 3T and 7T. ASSESSMENT Subjective image quality of 4D MRA was evaluated using a 4-point scale by two experienced neuroradiologists. The characterization of AVM components with 4D MRA and DSA was also graded using the Spetzler-Martin grading scale. STATISTICAL TESTS Cohen's kappa coefficient was calculated to evaluate the agreement between two readers within each 4D MRA technique (Cartesian and Radial). A Wilcoxon signed-rank test was performed to compare the subjective image quality scores of 4D MRA between Cartesian and radial trajectories, and between 7T and 3T, respectively. RESULTS Good-to-excellent image quality was achieved in 4D MRA with both Cartesian (3.83 ± 0.41) and radial (3.42 ± 0.49) acquisitions in healthy volunteers at 7T. However, markedly reduced scan time was needed with radial acquisition. 4D MRA at 7T (3.31 ± 0.59) shows better delineation of AVM lesion features, especially the vein drainage, compared with that of 3T (2.83 ± 0.75), although no statistical significance was achieved (P = 0.180). DATA CONCLUSION The feasibility of ASL based 4D MRA at 7T with Cartesian and SOS golden angle radial acquisition was demonstrated. The clinical evaluation of 4D MRA in AVMs between 3T and 7T suggested 7T 4D MRA images acquired with radial acquisition demonstrate excellent delineation of AVM features, especially the draining veins. LEVEL OF EVIDENCE 2 Technical Efficacy Stage 2 J. Magn. Reson. Imaging 2017.
Collapse
Affiliation(s)
- Fei Cong
- State Key Laboratory of Brain and Cognitive Science, Beijing MR Center for Brain Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, China.,University of Chinese Academy of Sciences, Beijing, China
| | - Yan Zhuo
- State Key Laboratory of Brain and Cognitive Science, Beijing MR Center for Brain Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, China
| | - Songlin Yu
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Xianchang Zhang
- State Key Laboratory of Brain and Cognitive Science, Beijing MR Center for Brain Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, China.,University of Chinese Academy of Sciences, Beijing, China
| | - Xinyuan Miao
- State Key Laboratory of Brain and Cognitive Science, Beijing MR Center for Brain Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, China
| | - Jing An
- Siemens Shenzhen Magnetic Resonance Ltd., Siemens MRI Center, Shenzhen, Guangdong, China
| | - Shuo Wang
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Yong Cao
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Yan Zhang
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Hee Kwon Song
- Department of Radiology, University of Pennsylvania Medical Center, Philadelphia, Pennsylvania, USA
| | - Danny Jj Wang
- Laboratory of Functional MRI Technology (LOFT), Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, California, USA
| | - Lirong Yan
- Laboratory of Functional MRI Technology (LOFT), Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, California, USA
| |
Collapse
|
25
|
Martin T, Hoffman J, Alger JR, McNitt-Gray M, Wang DJ. Low-dose CT perfusion with projection view sharing. Med Phys 2017; 45:101-113. [PMID: 29080274 DOI: 10.1002/mp.12640] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2017] [Revised: 10/13/2017] [Accepted: 10/19/2017] [Indexed: 12/25/2022] Open
Abstract
PURPOSE CT Perfusion (CTP) is a widely used clinical imaging modality. However, CTP typically involves the use of substantial radiation dose (CTDIvol ≥~200 mGy). The purpose of this study is to present a low-dose CTP technique using a projection view-sharing reconstruction algorithm originally developed for dynamic MRI - "K-space Weighted Image Contrast" (KWIC). METHODS The KWIC reconstruction is based on an angle-bisection scheme. In KWIC, a Fourier transform was performed along each projection to form a "k-space"-like CT data space, based on the central-slice theorem. As a projection view-sharing technique, KWIC preserves the spatiotemporal resolution of undersampled CTP data by progressively increasing the number of projection views shared for more distant regions of "k-space". KWIC reconstruction was evaluated on a digital FORBILD head phantom with numerically simulated time-varying objects. The numerically simulated scans were undersampled using the angle-bisection scheme to achieve 50%, 25%, and 12.5% of the original dose (288, 144, and 72 projections, respectively). The area-under-the-curve (AUC), time-to-peak (TTP), and full width half maximum (FWHM) were measured in KWIC recons and compared to fully sampled filtered back projection (FBP) reconstructions. KWIC reconstruction and dose reduction was also implemented for three clinical CTP cases (45 s, 1156 projections per turn, 1 s/turn, CTDIvol 217 mGy). Quantitative perfusion metrics were computed and compared between KWIC reconstructed CTP data and those of standard FBP reconstruction. RESULTS The AUC, TTP, and FWHM in the numerical simzulations were unaffected by the undersampling/dose reduction (down to 12.5% dose) with KWIC reconstruction compared to the fully sampled FBP reconstruction. The normalized root-mean-square-error (NRMSE) of the AUC in the FORBILD head phantom is 0.04, 0.05, and 0.07 for 50%, 25%, and 12.5% KWIC, respectively, as compared to FBP reconstruction. The cerebral blood flow (CBF) and cerebral blood volume had no significant difference between FBP and 50%, 25%, and 12.5% KWIC reconstructions (P > 0.05). CONCLUSIONS This study demonstrates that KWIC preserves perfusion metrics for CTP with substantially reduced dose. Clinical implementation will require further investigation into methods of rapid switching of a CT x-ray source.
Collapse
Affiliation(s)
- Thomas Martin
- Department of Neurology, University of California Los Angeles, Los Angeles, CA, USA
| | - John Hoffman
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, CA, USA
| | - Jeff R Alger
- Department of Neurology, University of California Los Angeles, Los Angeles, CA, USA
| | - Michael McNitt-Gray
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, CA, USA
| | - Danny Jj Wang
- Department of Neurology, University of California Los Angeles, Los Angeles, CA, USA.,Laboratory of FMRI Technology (LOFT), Stevens Neuroimaging and Informatics Institute, University of Southern California, Los Angeles, CA, USA
| |
Collapse
|
26
|
Geri O, Shiran SI, Roth J, Artzi M, Ben-Sira L, Ben Bashat D. Vascular territorial segmentation and volumetric blood flow measurement using dynamic contrast enhanced magnetic resonance angiography of the brain. J Cereb Blood Flow Metab 2017; 37:3446-3456. [PMID: 28393638 PMCID: PMC5624396 DOI: 10.1177/0271678x17702394] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
This study proposes a method for territorial segmentation and volumetric flow rate (VFR) distribution measurement of cerebral territories based on time-resolved contrast enhanced magnetic-resonance-angiography (MRA). The method uses an iterative region-growing algorithm based on bolus-arrival-time with increased temporal resolution. Eight territories were segmented: (1) right and (2) left internal carotid arteries, including the middle cerebral artery (ICA+MCA), excluding the anterior cerebral arteries (ACA); (3) right and left ACA (R+L-ACA); (4) right and (5) left external carotid arteries (ECA); (6) right and (7) left posterior cerebral arteries (PCA); and (8) vertebrobasilar territory. VFR percentage, relative to the entire brain (rVFR), was measured based on territorial volume as a function of time. Mean rVFR values of fifteen healthy subjects were: ICA+MCA = 23 ± 2%, R + L-ACA = 17 ± 3%, ECA = 4 ± 2%, PCA = 12 ± 2%, and vertebrobasilar territory = 31 ± 4%. Excluding the ECA-rVFR, which is underestimated, these values are comparable to previously reported values. Six subjects were scanned twice, demonstrating comparable and even higher reproducibility than previously reported using phase-contrast, yet with faster scan time (∼1 min). This method was implemented in one patient with MCA occlusion and one with Moyamoya syndrome scanned before and after bypass surgery, demonstrating its clinical potential for quantitative assessment of the degree of occlusion and the effect of surgery.
Collapse
Affiliation(s)
- Oren Geri
- 1 Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.,2 Sagol School of Neuroscience, Tel Aviv University, Tel Aviv, Israel
| | - Shelly I Shiran
- 3 Department of Radiology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
| | - Jonathan Roth
- 4 Department of NeuroSurgery, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
| | - Moran Artzi
- 1 Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.,5 Sackler Faculty of Medicine, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
| | - Liat Ben-Sira
- 3 Department of Radiology, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.,5 Sackler Faculty of Medicine, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
| | - Dafna Ben Bashat
- 1 Functional Brain Center, The Wohl Institute for Advanced Imaging, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel.,2 Sagol School of Neuroscience, Tel Aviv University, Tel Aviv, Israel.,5 Sackler Faculty of Medicine, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
| |
Collapse
|
27
|
Zhou Z, Han F, Yu S, Yu D, Rapacchi S, Song HK, Wang DJJ, Hu P, Yan L. Accelerated noncontrast-enhanced 4-dimensional intracranial MR angiography using golden-angle stack-of-stars trajectory and compressed sensing with magnitude subtraction. Magn Reson Med 2017; 79:867-878. [PMID: 28480537 DOI: 10.1002/mrm.26747] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2017] [Revised: 04/12/2017] [Accepted: 04/14/2017] [Indexed: 11/10/2022]
Abstract
PURPOSE To evaluate the feasibility and performance of compressed sensing (CS) with magnitude subtraction regularization in accelerating non-contrast-enhanced dynamic intracranial MR angiography (NCE-dMRA). METHODS A CS algorithm was introduced in NCE-dMRA by exploiting the sparsity of the magnitude difference of the control and label images. The NCE-dMRA data were acquired using golden-angle stack-of-stars trajectory on six healthy volunteers and one patient with arteriovenous fistula. Images were reconstructed using (i) the proposed magnitude-subtraction CS (MS-CS); (ii) complex-subtraction CS; (iii) independent CS; and (iv) view-sharing with k-space weighted image contrast (KWIC). The dMRA image quality was compared across the four reconstruction strategies. The proposed MS-CS method was further compared with KWIC for temporal fidelity of depicting dynamic flow. RESULTS The proposed MS-CS method was able to reconstruct NCE-dMRA images with detailed vascular structures and clean background. It provided better subjective image quality than the other two CS strategies (P < 0.05). Compared with KWIC, MS-CS showed similar image quality, but reduced temporal blurring in delineating the fine distal arteries. CONCLUSIONS The MS-CS method is a promising CS technique for accelerating NCE-dMRA acquisition without compromising image quality and temporal fidelity. Magn Reson Med 79:867-878, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Ziwu Zhou
- Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, California, USA.,Department of Bioengineering, University of California, Los Angeles, California, USA
| | - Fei Han
- Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, California, USA.,Department of Bioengineering, University of California, Los Angeles, California, USA
| | - Songlin Yu
- Department of Neurology, University of California, Los Angeles, California, USA.,Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, China
| | - Dandan Yu
- Department of Neurology, University of California, Los Angeles, California, USA
| | - Stanislas Rapacchi
- Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, California, USA
| | - Hee Kwon Song
- Department of Radiology, University of Pennsylvania Medical Center, Philadelphia, Pennsylvania, USA
| | - Danny J J Wang
- Laboratory of Functional MRI Technology, Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, California, USA
| | - Peng Hu
- Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, California, USA.,Department of Bioengineering, University of California, Los Angeles, California, USA
| | - Lirong Yan
- Laboratory of Functional MRI Technology, Stevens Neuroimaging and Informatics Institute, Keck School of Medicine, University of Southern California, Los Angeles, California, USA
| |
Collapse
|
28
|
Liu Y, Zhang Y, Wu C, Zhu J, Wang C, Tomko N, Linetsky MD, Salomon RG, Ramos-Estebanez C, Wang Y, Yu X. High-resolution dynamic oxygen-17 MR imaging of mouse brain with golden-ratio-based radial sampling and k-space-weighted image reconstruction. Magn Reson Med 2017; 79:256-263. [PMID: 28295552 DOI: 10.1002/mrm.26669] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2016] [Revised: 02/07/2017] [Accepted: 02/14/2017] [Indexed: 12/20/2022]
Abstract
PURPOSE The current study aimed to develop a three-dimensional (3D) dynamic oxygen-17 (17 O) MR imaging method with high temporal and spatial resolution to delineate the kinetics of 17 O water uptake and washout in the brains of mice with glioblastoma (GBM). METHODS A 3D imaging method with a stack-of-stars golden-ratio-based radial sampling scheme was employed to acquire 17 O signal in vivo. A k-space-weighted image reconstruction method was used to improve the temporal resolution while preserving spatial resolution. Simulation studies were performed to validate the method. Using this method, the kinetics of 17 O water uptake and washout in the brains of mice with GBM were delineated after an intravenous bolus injection of 17 O water. RESULTS The proposed 17 O imaging method achieved an effective temporal resolution of 7.56 s with a nominal voxel size of 5.625 μL in the mouse brain at 9.4 T. Reduced uptake and prolonged washout of 17 O water were observed in tumor tissue, suggesting compromised cerebral perfusion. CONCLUSION This study demonstrated a promising dynamic 17 O imaging approach that can delineate 17 O water kinetics in vivo with high temporal and spatial resolution. It can also be used to image cerebral oxygen consumption rate in oxygen-17 inhalation studies. Magn Reson Med 79:256-263, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Yuchi Liu
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA.,Case Center for Imaging Research, Case Western Reserve University, Cleveland, Ohio, USA
| | - Yifan Zhang
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA.,Case Center for Imaging Research, Case Western Reserve University, Cleveland, Ohio, USA
| | - Chunying Wu
- Case Center for Imaging Research, Case Western Reserve University, Cleveland, Ohio, USA.,Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
| | - Junqing Zhu
- Case Center for Imaging Research, Case Western Reserve University, Cleveland, Ohio, USA.,Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
| | - Charlie Wang
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA.,Case Center for Imaging Research, Case Western Reserve University, Cleveland, Ohio, USA
| | - Nicholas Tomko
- Department of Chemistry, Case Western Reserve University, Cleveland, Ohio, USA
| | - Mikhail D Linetsky
- Department of Chemistry, Case Western Reserve University, Cleveland, Ohio, USA
| | - Robert G Salomon
- Department of Chemistry, Case Western Reserve University, Cleveland, Ohio, USA
| | | | - Yanming Wang
- Case Center for Imaging Research, Case Western Reserve University, Cleveland, Ohio, USA.,Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA
| | - Xin Yu
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio, USA.,Case Center for Imaging Research, Case Western Reserve University, Cleveland, Ohio, USA.,Department of Radiology, Case Western Reserve University, Cleveland, Ohio, USA.,Department of Physiology and Biophysics, Case Western Reserve University, Cleveland, Ohio, USA
| |
Collapse
|
29
|
Ozyurt O, Dincer A, Erdem Yildiz M, Peker S, Yilmaz M, Sengoz M, Ozturk C. Integration of arterial spin labeling into stereotactic radiosurgery planning of cerebral arteriovenous malformations. J Magn Reson Imaging 2017; 46:1718-1727. [DOI: 10.1002/jmri.25690] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2016] [Accepted: 02/13/2017] [Indexed: 11/06/2022] Open
Affiliation(s)
- Onur Ozyurt
- Bogazici University; Institute of Biomedical Engineering; Istanbul Turkey
- Acibadem University; Neuroradiology Research Center; Istanbul Turkey
| | - Alp Dincer
- Acibadem University; Neuroradiology Research Center; Istanbul Turkey
- Acibadem University; Department of Radiology, School of Medicine; Istanbul Turkey
| | - Mehmet Erdem Yildiz
- Acibadem University; Neuroradiology Research Center; Istanbul Turkey
- Acibadem University; Department of Radiology, School of Medicine; Istanbul Turkey
| | - Selcuk Peker
- Acibadem University; Department of Neurosurgery, School of Medicine; Istanbul Turkey
| | - Meltem Yilmaz
- Acibadem Kozyatagi Hospital; Department of Radiation Oncology, School of Medicine; Istanbul Turkey
| | - Meric Sengoz
- Acibadem Kozyatagi Hospital; Department of Radiation Oncology, School of Medicine; Istanbul Turkey
| | - Cengizhan Ozturk
- Bogazici University; Institute of Biomedical Engineering; Istanbul Turkey
- Bogazici University; Center for Life Sciences and Technologies; Istanbul Turkey
| |
Collapse
|
30
|
Zhou Z, Han F, Yan L, Wang DJJ, Hu P. Golden-ratio rotated stack-of-stars acquisition for improved volumetric MRI. Magn Reson Med 2017; 78:2290-2298. [PMID: 28168738 DOI: 10.1002/mrm.26625] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2016] [Revised: 12/22/2016] [Accepted: 01/09/2017] [Indexed: 11/06/2022]
Abstract
PURPOSE To develop and evaluate an improved stack-of-stars radial sampling strategy for reducing streaking artifacts. METHODS The conventional stack-of-stars sampling strategy collects the same radial angle for every partition (slice) encoding. In an undersampled acquisition, such an aligned acquisition generates coherent aliasing patterns and introduces strong streaking artifacts. We show that by rotating the radial spokes in a golden-angle manner along the partition-encoding direction, the aliasing pattern is modified, resulting in improved image quality for gridding and more advanced reconstruction methods. Computer simulations were performed and phantom as well as in vivo images for three different applications were acquired. RESULTS Simulation, phantom, and in vivo experiments confirmed that the proposed method was able to generate images with less streaking artifact and sharper structures based on undersampled acquisitions in comparison with the conventional aligned approach at the same acceleration factors. By combining parallel imaging and compressed sensing in the reconstruction, streaking artifacts were mostly removed with improved delineation of fine structures using the proposed strategy. CONCLUSIONS We present a simple method to reduce streaking artifacts and improve image quality in 3D stack-of-stars acquisitions by re-arranging the radial spoke angles in the 3D partition direction, which can be used for rapid volumetric imaging. Magn Reson Med 78:2290-2298, 2017. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Ziwu Zhou
- Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, California, USA.,Department of Bioengineering, University of California, Los Angeles, California, USA
| | - Fei Han
- Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, California, USA.,Department of Bioengineering, University of California, Los Angeles, California, USA
| | - Lirong Yan
- Laboratory of Functional MRI Technology (LOFT), Stevens Neuroimaging and Informatics Institute, Department of Neurology, University of Southern California, Los Angeles, California, USA
| | - Danny J J Wang
- Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, California, USA.,Laboratory of Functional MRI Technology (LOFT), Stevens Neuroimaging and Informatics Institute, Department of Neurology, University of Southern California, Los Angeles, California, USA
| | - Peng Hu
- Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, California, USA.,Biomedical Physics Interdepartmental Graduate Program, University of California, Los Angeles, California, USA
| |
Collapse
|
31
|
Okell TW, Schmitt P, Bi X, Chappell MA, Tijssen RHN, Sheerin F, Miller KL, Jezzard P. Optimization of 4D vessel-selective arterial spin labeling angiography using balanced steady-state free precession and vessel-encoding. NMR IN BIOMEDICINE 2016; 29:776-786. [PMID: 27074149 PMCID: PMC4879350 DOI: 10.1002/nbm.3515] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/25/2015] [Revised: 01/14/2016] [Accepted: 02/19/2016] [Indexed: 06/05/2023]
Abstract
Vessel-selective dynamic angiograms provide a wealth of useful information about the anatomical and functional status of arteries, including information about collateral flow and blood supply to lesions. Conventional x-ray techniques are invasive and carry some risks to the patient, so non-invasive alternatives are desirable. Previously, non-contrast dynamic MRI angiograms based on arterial spin labeling (ASL) have been demonstrated using both spoiled gradient echo (SPGR) and balanced steady-state free precession (bSSFP) readout modules, but no direct comparison has been made, and bSSFP optimization over a long readout period has not been fully explored. In this study bSSFP and SPGR are theoretically and experimentally compared for dynamic ASL angiography. Unlike SPGR, bSSFP was found to have a very low ASL signal attenuation rate, even when a relatively large flip angle and short repetition time were used, leading to a threefold improvement in the measured signal-to-noise ratio (SNR) efficiency compared with SPGR. For vessel-selective applications, SNR efficiency can be further improved over single-artery labeling methods by using a vessel-encoded pseudo-continuous ASL (VEPCASL) approach. The combination of a VEPCASL preparation with a time-resolved bSSFP readout allowed the generation of four-dimensional (4D; time-resolved three-dimensional, 3D) vessel-selective cerebral angiograms in healthy volunteers with 59 ms temporal resolution. Good quality 4D angiograms were obtained in all subjects, providing comparable structural information to 3D time-of-flight images, as well as dynamic information and vessel selectivity, which was shown to be high. A rapid 1.5 min dynamic two-dimensional version of the sequence yielded similar image features and would be suitable for a busy clinical protocol. Preliminary experiments with bSSFP that included the extracranial vessels showed signal loss in regions of poor magnetic field homogeneity. However, for intracranial vessel-selective angiography, the proposed bSSFP VEPCASL sequence is highly SNR efficient and could provide useful information in a range of cerebrovascular diseases. © 2016 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd.
Collapse
Affiliation(s)
- Thomas W. Okell
- FMRIB CentreNuffield Department of Clinical NeurosciencesUniversity of OxfordOxfordUK
| | - Peter Schmitt
- MR Application and Workflow DevelopmentSiemens AG, Healthcare SectorErlangenGermany
| | | | - Michael A. Chappell
- FMRIB CentreNuffield Department of Clinical NeurosciencesUniversity of OxfordOxfordUK
- Institute of Biomedical EngineeringUniversity of OxfordOxfordUK
| | - Rob H. N. Tijssen
- FMRIB CentreNuffield Department of Clinical NeurosciencesUniversity of OxfordOxfordUK
- Department of RadiotherapyUniversity Medical Center UtrechtUtrechtThe Netherlands
| | - Fintan Sheerin
- NeuroradiologyOxford University Hospitals NHS TrustOxfordUK
| | - Karla L. Miller
- FMRIB CentreNuffield Department of Clinical NeurosciencesUniversity of OxfordOxfordUK
| | - Peter Jezzard
- FMRIB CentreNuffield Department of Clinical NeurosciencesUniversity of OxfordOxfordUK
| |
Collapse
|
32
|
Whole heart coronary imaging with flexible acquisition window and trigger delay. PLoS One 2015; 10:e0112020. [PMID: 25719750 PMCID: PMC4342264 DOI: 10.1371/journal.pone.0112020] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2014] [Accepted: 08/27/2014] [Indexed: 11/18/2022] Open
Abstract
Coronary magnetic resonance imaging (MRI) requires a correctly timed trigger delay derived from a scout cine scan to synchronize k-space acquisition with the quiescent period of the cardiac cycle. However, heart rate changes between breath-held cine and free-breathing coronary imaging may result in inaccurate timing errors. Additionally, the determined trigger delay may not reflect the period of minimal motion for both left and right coronary arteries or different segments. In this work, we present a whole-heart coronary imaging approach that allows flexible selection of the trigger delay timings by performing k-space sampling over an enlarged acquisition window. Our approach addresses coronary motion in an interactive manner by allowing the operator to determine the temporal window with minimal cardiac motion for each artery region. An electrocardiogram-gated, k-space segmented 3D radial stack-of-stars sequence that employs a custom rotation angle is developed. An interactive reconstruction and visualization platform is then employed to determine the subset of the enlarged acquisition window for minimal coronary motion. Coronary MRI was acquired on eight healthy subjects (5 male, mean age = 37 ± 18 years), where an enlarged acquisition window of 166–220 ms was set 50 ms prior to the scout-derived trigger delay. Coronary visualization and sharpness scores were compared between the standard 120 ms window set at the trigger delay, and those reconstructed using a manually adjusted window. The proposed method using manual adjustment was able to recover delineation of five mid and distal right coronary artery regions that were otherwise not visible from the standard window, and the sharpness scores improved in all coronary regions using the proposed method. This paper demonstrates the feasibility of a whole-heart coronary imaging approach that allows interactive selection of any subset of the enlarged acquisition window for a tailored reconstruction for each branch region.
Collapse
|