1
|
Selby NM, Francis ST. Assessment of Acute Kidney Injury using MRI. J Magn Reson Imaging 2025; 61:25-41. [PMID: 38334370 PMCID: PMC11645494 DOI: 10.1002/jmri.29281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 01/19/2024] [Accepted: 01/23/2024] [Indexed: 02/10/2024] Open
Abstract
There has been growing interest in using quantitative magnetic resonance imaging (MRI) to describe and understand the pathophysiology of acute kidney injury (AKI). The ability to assess kidney blood flow, perfusion, oxygenation, and changes in tissue microstructure at repeated timepoints is hugely appealing, as this offers new possibilities to describe nature and severity of AKI, track the time-course to recovery or progression to chronic kidney disease (CKD), and may ultimately provide a method to noninvasively assess response to new therapies. This could have significant clinical implications considering that AKI is common (affecting more than 13 million people globally every year), harmful (associated with short and long-term morbidity and mortality), and currently lacks specific treatments. However, this is also a challenging area to study. After the kidney has been affected by an initial insult that leads to AKI, complex coexisting processes ensue, which may recover or can progress to CKD. There are various preclinical models of AKI (from which most of our current understanding derives), and these differ from each other but more importantly from clinical AKI. These aspects are fundamental to interpreting the results of the different AKI studies in which renal MRI has been used, which encompass different settings of AKI and a variety of MRI measures acquired at different timepoints. This review aims to provide a comprehensive description and interpretation of current studies (both preclinical and clinical) in which MRI has been used to assess AKI, and discuss future directions in the field. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 3.
Collapse
Affiliation(s)
- Nicholas M Selby
- Centre for Kidney Research and Innovation, Academic Unit for Translational Medical Sciences, School of Medicine, University of Nottingham, Nottingham, UK
- Department of Renal Medicine, University Hospitals of Derby and Burton NHS Foundation Trust, Derby, UK
| | - Susan T Francis
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
- NIHR Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust and The University of Nottingham, Nottingham, UK
| |
Collapse
|
2
|
Klinkhammer BM, Ay I, Caravan P, Caroli A, Boor P. Advances in Molecular Imaging of Kidney Diseases. Nephron Clin Pract 2024; 149:149-159. [PMID: 39496240 DOI: 10.1159/000542412] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2024] [Accepted: 10/20/2024] [Indexed: 11/06/2024] Open
Abstract
BACKGROUND Diagnosing and monitoring kidney diseases traditionally rely on blood and urine analyses and invasive procedures such as kidney biopsies, the latter offering limited possibilities for longitudinal monitoring and a comprehensive understanding of disease dynamics. Current noninvasive methods lack specificity in capturing intrarenal molecular processes, hindering patient stratification and patient monitoring in clinical practice and clinical trials. SUMMARY Molecular imaging enables noninvasive and quantitative assessment of physiological and pathological molecular processes. By using specific molecular probes and imaging technologies, e.g., magnetic resonance imaging, positron emission tomography, single-photon emission computed tomography, or ultrasound, molecular imaging allows the detection and longitudinal monitoring of disease activity with spatial and temporal resolution of different kidney diseases and disease-specific pathways. Several approaches have already shown promising results in kidneys and exploratory clinical studies, and validation is needed before implementation in clinical practice. KEY MESSAGES Molecular imaging offers a noninvasive assessment of intrarenal molecular processes, overcoming the limitations of current diagnostic methods. It has the potential to serve as companion diagnostics, not only in clinical trials, aiding in patient stratification and treatment response assessment. By guiding therapeutic interventions, molecular imaging might contribute to the development of targeted therapies for kidney diseases.
Collapse
Affiliation(s)
| | - Ilknur Ay
- Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Peter Caravan
- Institute for Innovation in Imaging, Department of Radiology, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Anna Caroli
- Bioengineering Department, Istituto di Ricerche Farmacologiche Mario Negri IRCCS, Milan, Italy
| | - Peter Boor
- Institute for Pathology, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
3
|
Tao Q, Zhang Q, An Z, Chen Z, Feng Y. Multi-Parametric MRI for Evaluating Variations in Renal Structure, Function, and Endogenous Metabolites in an Animal Model With Acute Kidney Injury Induced by Ischemia Reperfusion. J Magn Reson Imaging 2024; 60:245-255. [PMID: 37881827 DOI: 10.1002/jmri.29094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2023] [Revised: 10/12/2023] [Accepted: 10/12/2023] [Indexed: 10/27/2023] Open
Abstract
BACKGROUND Ischemia reperfusion injury (IRI)-induced acute kidney injury (AKI) may occur after renal ischemic injury. There is a lack of an accurate and comprehensive detection technique for IRI-AKI. PURPOSE To longitudinally evaluate IRI-AKI in rats by renal structure, function, and metabolites using multi-parametric MRI (mpMRI). STUDY TYPE Prospective. ANIMAL MODEL Forty-eight rats undergoing IRI-AKI. FIELD STRENGTH/SEQUENCE 7-T, T1 mapping, and arterial spin labeling (ASL): echo planar imaging (EPI) sequence; blood oxygen level-dependent (BOLD): gradient recalled echo (GRE) sequence; T2 mapping, quantitative magnetization transfer (qMT), and chemical exchange saturation transfer (CEST): rapid acquisition with relaxation enhancement (RARE) sequence. ASSESSMENT The mpMRI for IRI-AKI was conducted at 0 (control), 1, 3, 7, 14, and 28 days, all included eight rats. The longitudinal mpMRI signal of manually outlined cortex, outer stripe of the outer medulla (OSOM), inner stripe of the outer medulla, and medulla plus pelvis were calculated and compared, their diagnosis performance for IRI-AKI also been evaluated. STATISTICAL TESTS Pearson correlations analysis for correlation between mpMRI signal and renal injury, unpaired t-tests for comparing the signal changes, and receiver operating characteristics (ROC) analysis was used to identify most sensitive indicator of mpMRI. A P-value <0.05 was considered statistically significant. RESULTS Compared with control kidneys, the T1 and T2 values of the cortex and medulla in IRI kidneys increased and reached their highest values on day 14, and the kidneys also showed the most severe edema and segments blurred. The RBF in the cortex and OSOM showed a significant decline after day 3. The BOLD signal in the OSOM largest increased on day 28. The cortical PSR and the amine-CEST both decreased with IRI-AKI progression, and amine-CEST achieved the highest AUC for the diagnosis (0.899). DATA CONCLUSION Multi-parametric MRI may show comprehensive variations in IRI-AKI, and amine-CEST may exhibit the highest accuracy for diagnosis of IRI-AKI. LEVEL OF EVIDENCE 1 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Quan Tao
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China
- Guangdong Provincial Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
| | - Qianqian Zhang
- Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China
- Guangdong Provincial Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China
| | - Ziqi An
- Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China
- Guangdong Provincial Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China
| | - Zelong Chen
- Medical Imaging Center, Nanfang Hospital, Southern Medical University, Guangzhou, China
| | - Yanqiu Feng
- Department of Rehabilitation Medicine, Zhujiang Hospital, Southern Medical University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Medical Image Processing, Southern Medical University, Guangzhou, China
- Guangdong Provincial Engineering Laboratory for Medical Imaging and Diagnostic Technology, Southern Medical University, Guangzhou, China
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China
| |
Collapse
|
4
|
Zhao D, Wang W, Niu YY, Ren XH, Shen AJ, Xiang YS, Xie HY, Wu LH, Yu C, Zhang YY. Amide Proton Transfer-Weighted Magnetic Resonance Imaging for Application in Renal Fibrosis: A Radiological-Pathological-Based Analysis. Am J Nephrol 2024; 55:334-344. [PMID: 38228096 DOI: 10.1159/000536232] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2023] [Accepted: 01/04/2024] [Indexed: 01/18/2024]
Abstract
INTRODUCTION Renal fibrosis (RF), being the most important pathological change in the progression of CKD, is currently assessed by the evaluation of a biopsy. This present study aimed to apply a novel functional MRI (fMRI) protocol named amide proton transfer (APT) weighting to evaluate RF noninvasively. METHODS Male Sprague-Dawley (SD) rats were initially subjected to bilateral kidney ischemia/reperfusion injury (IRI), unilateral ureteral obstruction, and sham operation, respectively. All rats underwent APT mapping on the 7th and 14th days after operation. Besides, 26 patients underwent renal biopsy at the Nephrology Department of Shanghai Tongji Hospital between July 2022 and May 2023. Patients underwent APT and apparent diffusion coefficient (ADC) mappings within 1 week before biopsy. MRI results of both patients and rats were calculated by comparing with gold standard histology for fibrosis assessment. RESULTS In animal models, the cortical APT (cAPT) and medullary APT (mAPT) values were positively correlated with the degree of RF. Compared to the sham group, IRI group showed significantly increased cAPT and mAPT values on the 7th and 14th days after surgery, but no group differences were found in ADC values. Similar results were found in human patients. Cortical/medullary APT values were significantly increased in patients with moderate-to-severe fibrosis than in patients with mild fibrosis. ROC curve analysis indicated that APT value displayed a better diagnostic value for RF. Furthermore, combination of cADC and cAPT improved fibrosis detection by imaging variables alone (p < 0.1). CONCLUSION APT values had better diagnostic capability at early stage of RF compared to ADC values, and the addition of APT imaging to conventional ADC will significantly improve the diagnostic performance for predicting kidney fibrosis.
Collapse
Affiliation(s)
- Dan Zhao
- Department of Nephrology, Shanghai Tongji Hospital, Tongji University School of Medicine, Shanghai, China,
| | - Wei Wang
- Department of Radiology, Shanghai Tongji Hospital, Tongji University School of Medicine, Shanghai, China
| | - Yang-Yang Niu
- Department of Nephrology, Shanghai Tongji Hospital, Tongji University School of Medicine, Shanghai, China
| | - Xi-Hui Ren
- Department of Radiology, Shanghai Tongji Hospital, Tongji University School of Medicine, Shanghai, China
| | - Ai-Jun Shen
- Department of Radiology, Shanghai Tongji Hospital, Tongji University School of Medicine, Shanghai, China
| | - Yong-Sheng Xiang
- Department of Radiology, Shanghai Tongji Hospital, Tongji University School of Medicine, Shanghai, China
| | - Hong-Yan Xie
- Department of Nephrology, Shanghai Tongji Hospital, Tongji University School of Medicine, Shanghai, China
| | - Le-Hao Wu
- Department of Nephrology, Shanghai Tongji Hospital, Tongji University School of Medicine, Shanghai, China
| | - Chen Yu
- Department of Nephrology, Shanghai Tongji Hospital, Tongji University School of Medicine, Shanghai, China
| | - Ying-Ying Zhang
- Department of Nephrology, Shanghai Tongji Hospital, Tongji University School of Medicine, Shanghai, China
| |
Collapse
|
5
|
Wang B, Wang Y, Wang J, Jin C, Zhou R, Guo J, Zhang H, Wang M. Multiparametric Magnetic Resonance Investigations on Acute and Long-Term Kidney Injury. J Magn Reson Imaging 2024; 59:43-57. [PMID: 37246343 DOI: 10.1002/jmri.28784] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2022] [Revised: 04/29/2023] [Accepted: 05/01/2023] [Indexed: 05/30/2023] Open
Abstract
Acute kidney injury (AKI) is a frequent complication of critical illness and carries a significant risk of short- and long-term mortality. The prediction of the progression of AKI to long-term injury has been difficult for renal disease treatment. Radiologists are keen for the early detection of transition from AKI to long-term kidney injury, which would help in the preventive measures. The lack of established methods for early detection of long-term kidney injury underscores the pressing needs of advanced imaging technology that reveals microscopic tissue alterations during the progression of AKI. Fueled by recent advances in data acquisition and post-processing methods of magnetic resonance imaging (MRI), multiparametric MRI is showing great potential as a diagnostic tool for many kidney diseases. Multiparametric MRI studies offer a precious opportunity for real-time noninvasive monitoring of pathological development and progression of AKI to long-term injury. It provides insight into renal vasculature and function (arterial spin labeling, intravoxel incoherent motion), tissue oxygenation (blood oxygen level-dependent), tissue injury and fibrosis (diffusion tensor imaging, diffusion kurtosis imaging, T1 and T2 mapping, quantitative susceptibility mapping). The multiparametric MRI approach is highly promising but the longitudinal investigation on the transition of AKI to irreversible long-term impairment is largely ignored. Further optimization and implementation of renal MR methods in clinical practice will enhance our comprehension of not only AKI but chronic kidney diseases. Novel imaging biomarkers for microscopic renal tissue alterations could be discovered and benefit the preventative interventions. This review explores recent MRI applications on acute and long-term kidney injury while addressing lingering challenges, with emphasis on the potential value of the development of multiparametric MRI for renal imaging on clinical systems. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Bin Wang
- Department of Medical Imaging, First Hospital of Shanxi Medical University, Taiyuan, Shanxi, China
- Department of Medical Imaging, Shanxi Medical University, Taiyuan, Shanxi, China
| | - Yongfang Wang
- Department of Medical Imaging, First Hospital of Shanxi Medical University, Taiyuan, Shanxi, China
| | - Jing Wang
- Department of Nuclear Medicine and PET Center, The Second Hospital of Zhejiang University School of Medicine, Hangzhou, China
- Key Laboratory of Medical Molecular Imaging of Zhejiang Province, Hangzhou, China
| | - Chentao Jin
- Department of Nuclear Medicine and PET Center, The Second Hospital of Zhejiang University School of Medicine, Hangzhou, China
- Key Laboratory of Medical Molecular Imaging of Zhejiang Province, Hangzhou, China
| | - Rui Zhou
- Department of Nuclear Medicine and PET Center, The Second Hospital of Zhejiang University School of Medicine, Hangzhou, China
- Key Laboratory of Medical Molecular Imaging of Zhejiang Province, Hangzhou, China
| | - Jinxia Guo
- GE Healthcare, MR Research China, Beijing, China
| | - Hong Zhang
- Department of Nuclear Medicine and PET Center, The Second Hospital of Zhejiang University School of Medicine, Hangzhou, China
- Key Laboratory of Medical Molecular Imaging of Zhejiang Province, Hangzhou, China
- Key Laboratory for Biomedical Engineering of Ministry of Education, Zhejiang University, Hangzhou, China
- College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, China
| | - Min Wang
- Key Laboratory for Biomedical Engineering of Ministry of Education, Zhejiang University, Hangzhou, China
- College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, China
| |
Collapse
|
6
|
Longo DL, Carella A, Corrado A, Pirotta E, Mohanta Z, Singh A, Stabinska J, Liu G, McMahon MT. A snapshot of the vast array of diamagnetic CEST MRI contrast agents. NMR IN BIOMEDICINE 2023; 36:e4715. [PMID: 35187749 PMCID: PMC9724179 DOI: 10.1002/nbm.4715] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/03/2021] [Revised: 02/17/2022] [Accepted: 02/18/2022] [Indexed: 05/11/2023]
Abstract
Since the inception of CEST MRI in the 1990s, a number of compounds have been identified as suitable for generating contrast, including paramagnetic lanthanide complexes, hyperpolarized atom cages and, most interesting, diamagnetic compounds. In the past two decades, there has been a major emphasis in this field on the identification and application of diamagnetic compounds that have suitable biosafety profiles for usage in medical applications. Even in the past five years there has been a tremendous growth in their numbers, with more and more emphasis being placed on finding those that can be ultimately used for patient studies on clinical 3 T scanners. At this point, a number of endogenous compounds present in tissue have been identified, and also natural and synthetic organic compounds that can be administered to highlight pathology via CEST imaging. Here we will provide a very extensive snapshot of the types of diamagnetic compound that can generate CEST MRI contrast, together with guidance on their utility on typical preclinical and clinical scanners and a review of the applications that might benefit the most from this new technology.
Collapse
Affiliation(s)
- Dario Livio Longo
- Institute of Biostructures and Bioimaging (IBB), National Research Council of Italy (CNR), Turin, Italy
| | - Antonella Carella
- Institute of Biostructures and Bioimaging (IBB), National Research Council of Italy (CNR), Turin, Italy
| | - Alessia Corrado
- Institute of Biostructures and Bioimaging (IBB), National Research Council of Italy (CNR), Turin, Italy
| | - Elisa Pirotta
- Institute of Biostructures and Bioimaging (IBB), National Research Council of Italy (CNR), Turin, Italy
| | - Zinia Mohanta
- F.M. Kirby Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Aruna Singh
- F.M. Kirby Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Julia Stabinska
- F.M. Kirby Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Guanshu Liu
- F.M. Kirby Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| | - Michael T. McMahon
- F.M. Kirby Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA
- Department of Radiology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA
| |
Collapse
|
7
|
Bo S, Zhang D, Ma M, Mo X, Stabinska J, McMahon MT, Shi C, Luo L. Acyl Hydrazides and Acyl Hydrazones as High-Performance Chemical Exchange Saturation Transfer MRI Contrast Agents. Pharmaceuticals (Basel) 2023; 16:ph16050639. [PMID: 37242423 DOI: 10.3390/ph16050639] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 04/17/2023] [Accepted: 04/20/2023] [Indexed: 05/28/2023] Open
Abstract
Chemical exchange saturation transfer (CEST) MRI is a versatile molecular imaging approach that holds great promise for clinical translation. A number of compounds have been identified as suitable for performing CEST MRI, including paramagnetic CEST (paraCEST) agents and diamagnetic CEST (diaCEST) agents. DiaCEST agents are very attractive because of their excellent biocompatibility and potential for biodegradation, such as glucose, glycogen, glutamate, creatine, nucleic acids, et al. However, the sensitivity of most diaCEST agents is limited because of small chemical shifts (1.0-4.0 ppm) from water. To expand the catalog of diaCEST agents with larger chemical shifts, herein, we have systematically investigated the CEST properties of acyl hydrazides with different substitutions, including aromatic and aliphatic substituents. We have tuned the labile proton chemical shifts from 2.8-5.0 ppm from water while exchange rates varied from ~680 to 2340 s-1 at pH 7.2, which allows strong CEST contrast on scanners down to B0 = 3 T. One acyl hydrazide, adipic acid dihydrazide (ADH), was tested on a mouse model of breast cancer and showed nice contrast in the tumor region. We also prepared a derivative, acyl hydrazone, which showed the furthest shifted labile proton (6.4 ppm from water) and excellent contrast properties. Overall, our study expands the catalog of diaCEST agents and their application in cancer diagnosis.
Collapse
Affiliation(s)
- Shaowei Bo
- Department of Medical Imaging, The Affiliated Guangdong Second Provincial General Hospital of Jinan University, Guangzhou 510317, China
| | - Dong Zhang
- Medical Imaging Center, The First Affiliated Hospital of Jinan University, Guangzhou 510632, China
| | - Mengjie Ma
- Medical Imaging Center, The First Affiliated Hospital of Jinan University, Guangzhou 510632, China
| | - Xukai Mo
- Medical Imaging Center, The First Affiliated Hospital of Jinan University, Guangzhou 510632, China
| | - Julia Stabinska
- The Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD 21287, USA
| | - Michael T McMahon
- The Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA
- F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, MD 21287, USA
| | - Changzheng Shi
- Medical Imaging Center, The First Affiliated Hospital of Jinan University, Guangzhou 510632, China
| | - Liangping Luo
- Department of Medical Imaging, The Affiliated Guangdong Second Provincial General Hospital of Jinan University, Guangzhou 510317, China
- Medical Imaging Center, The First Affiliated Hospital of Jinan University, Guangzhou 510632, China
| |
Collapse
|
8
|
Longo DL, Pirotta E, Gambino R, Romdhane F, Carella A, Corrado A. Tumor pH Imaging Using Chemical Exchange Saturation Transfer (CEST)-MRI. Methods Mol Biol 2023; 2614:287-311. [PMID: 36587132 DOI: 10.1007/978-1-0716-2914-7_18] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Magnetic resonance imaging (MRI) is a noninvasive imaging technique that allows for physiological and functional studies of the tumor microenvironment. Within MRI, the emerging field of chemical exchange saturation transfer (CEST) has been largely exploited for assessing a salient feature of all solid tumors, extracellular acidosis. Iopamidol-based tumor pH imaging has been demonstrated to provide accurate and high spatial resolution extracellular tumor pH maps to elucidate tumor aggressiveness and for assessing response to therapy, with a high potential for clinical translation. Here, we describe the overall setup and steps for measuring tumor extracellular pH of tumor models in mice by exploiting MRI-CEST pH imaging with a preclinical MRI scanner following the administration of iopamidol. We address issues of pH calibration curve setup, animal handling, pH-responsive contrast agent injection, acquisition protocol, and image processing for accurate quantification and visualization of tumor acidosis.
Collapse
Affiliation(s)
- Dario Livio Longo
- Institute of Biostructures and Bioimaging (IBB), Italian National Research Council (CNR), Torino, Italy.
| | - Elisa Pirotta
- Institute of Biostructures and Bioimaging (IBB), Italian National Research Council (CNR), Torino, Italy
| | - Riccardo Gambino
- Department of Molecular Biotechnology and Health Sciences, University of Torino, Torino, Italy
| | - Feriel Romdhane
- Institute of Biostructures and Bioimaging (IBB), Italian National Research Council (CNR), Torino, Italy
| | - Antonella Carella
- Institute of Biostructures and Bioimaging (IBB), Italian National Research Council (CNR), Torino, Italy
| | - Alessia Corrado
- Institute of Biostructures and Bioimaging (IBB), Italian National Research Council (CNR), Torino, Italy
| |
Collapse
|
9
|
Stabinska J, Singh A, Haney NM, Li Y, Sedaghat F, Kates M, McMahon MT. Noninvasive assessment of renal dynamics and
pH
in a unilateral ureter obstruction model using
DCE MR‐CEST
urography. Magn Reson Med 2022; 89:343-355. [PMID: 36089805 PMCID: PMC9753579 DOI: 10.1002/mrm.29436] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Revised: 06/29/2022] [Accepted: 08/10/2022] [Indexed: 11/10/2022]
Abstract
PURPOSE To assess the potential of DCE MR CEST urography for assessing renal function in mice with unilateral ureter obstruction (UUO) by simultaneous pH and renal uptake/clearance measurements following injection of iopamidol. METHODS The right ureter of nine mice was obstructed via suture ligation. The animals were imaged at day 1, 2, and 3 post-obstruction on an 11.7T MRI scanner. Ninety-six sets of saturated CEST images at 4.3 and 5.5 ppm were collected. Renal pH values were obtained by calculating the signal ratio for these two frequencies and using a pH calibration curve. Renal time activity curves were measured as a percentage change in the post-injection CEST signal at 4.3 ppm relative to the average pre-injection signal. RESULTS For the healthy mice, the time activity curves of both kidneys were nearly identical and displayed rapid excretion of contrast. For the UUO mice, the dynamic CEST curves for the obstructed kidneys displayed prolonged time to peak (TTP) values and delayed contrast excretion compared with the contralateral (CL) kidneys. Renal pH maps of the healthy animals showed similar acidic values for both kidneys (pH 6.65 ± 0.04 vs 6.67 ± 0.02), whereas in the obstructed kidneys there was a significant increase in pH values compared with the CL kidneys (pH 6.67 ± 0.08 vs 6.79 ± 0.11 in CL and UUO kidneys, respectively). CONCLUSION Our findings indicate that DCE-MR-CEST urography can detect changes in renal uptake/excretion and pH homeostasis and distinguish between obstructed and unobstructed kidney as early as 1 day after UUO.
Collapse
Affiliation(s)
- Julia Stabinska
- F.M. Kirby Research Center for Functional Brain Imaging Kennedy Krieger Institute Baltimore Maryland USA
- Russell H. Morgan Department of Radiology and Radiological Science Johns Hopkins University School of Medicine Baltimore Maryland USA
| | - Aruna Singh
- F.M. Kirby Research Center for Functional Brain Imaging Kennedy Krieger Institute Baltimore Maryland USA
- Russell H. Morgan Department of Radiology and Radiological Science Johns Hopkins University School of Medicine Baltimore Maryland USA
| | - Nora M. Haney
- James Buchanan Brady Urological Institute and Department of Urology Johns Hopkins University School of Medicine Baltimore Maryland USA
| | - Yuguo Li
- F.M. Kirby Research Center for Functional Brain Imaging Kennedy Krieger Institute Baltimore Maryland USA
- Russell H. Morgan Department of Radiology and Radiological Science Johns Hopkins University School of Medicine Baltimore Maryland USA
| | - Farzad Sedaghat
- Russell H. Morgan Department of Radiology and Radiological Science Johns Hopkins University School of Medicine Baltimore Maryland USA
| | - Max Kates
- James Buchanan Brady Urological Institute and Department of Urology Johns Hopkins University School of Medicine Baltimore Maryland USA
| | - Michael T. McMahon
- F.M. Kirby Research Center for Functional Brain Imaging Kennedy Krieger Institute Baltimore Maryland USA
- Russell H. Morgan Department of Radiology and Radiological Science Johns Hopkins University School of Medicine Baltimore Maryland USA
| |
Collapse
|
10
|
Brown M, Li J, Moraes C, Tabrizian M, Li-Jessen NY. Decellularized extracellular matrix: New promising and challenging biomaterials for regenerative medicine. Biomaterials 2022; 289:121786. [DOI: 10.1016/j.biomaterials.2022.121786] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Revised: 08/22/2022] [Accepted: 08/29/2022] [Indexed: 11/28/2022]
|
11
|
Klinkhammer BM, Lammers T, Mottaghy FM, Kiessling F, Floege J, Boor P. Non-invasive molecular imaging of kidney diseases. Nat Rev Nephrol 2021; 17:688-703. [PMID: 34188207 PMCID: PMC7612034 DOI: 10.1038/s41581-021-00440-4] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/10/2021] [Indexed: 02/05/2023]
Abstract
In nephrology, differential diagnosis or assessment of disease activity largely relies on the analysis of glomerular filtration rate, urinary sediment, proteinuria and tissue obtained through invasive kidney biopsies. However, currently available non-invasive functional parameters, and most serum and urine biomarkers, cannot capture intrarenal molecular disease processes specifically. Moreover, although histopathological analyses of kidney biopsy samples enable the visualization of pathological morphological and molecular alterations, they only provide information about a small part of the kidney and do not allow longitudinal monitoring. These limitations not only hinder understanding of the dynamics of specific disease processes in the kidney, but also limit the targeting of treatments to active phases of disease and the development of novel targeted therapies. Molecular imaging enables non-invasive and quantitative assessment of physiological or pathological processes by combining imaging technologies with specific molecular probes. Here, we discuss current preclinical and clinical molecular imaging approaches in nephrology. Non-invasive visualization of the kidneys through molecular imaging can be used to detect and longitudinally monitor disease activity and can therefore provide companion diagnostics to guide clinical trials, as well as the safe and effective use of drugs.
Collapse
Affiliation(s)
| | - Twan Lammers
- Institute for Experimental Molecular Imaging, RWTH Aachen University Hospital, Aachen, Germany
- Department of Pharmaceutics, Utrecht University, Utrecht, Netherlands
- Department of Targeted Therapeutics, University of Twente, Enschede, Netherlands
| | - Felix M Mottaghy
- Department of Nuclear Medicine, University Hospital RWTH, Aachen, Germany
- Department of Radiology and Nuclear Medicine, Maastricht University Medical Center, Maastricht, Netherlands
| | - Fabian Kiessling
- Institute for Experimental Molecular Imaging, RWTH Aachen University Hospital, Aachen, Germany
- Fraunhofer Institute for Digital Medicine MEVIS, Bremen, Germany
| | - Jürgen Floege
- Department of Nephrology and Immunology, RWTH Aachen University Hospital, Aachen, Germany
| | - Peter Boor
- Institute of Pathology, RWTH Aachen University Hospital, Aachen, Germany.
- Department of Nephrology and Immunology, RWTH Aachen University Hospital, Aachen, Germany.
- Electron Microscopy Facility, RWTH Aachen University Hospital, Aachen, Germany.
| |
Collapse
|
12
|
Song X, Zang Q, Zare RN. Hydrogen-Deuterium Exchange Desorption Electrospray Ionization Mass Spectrometry Visualizes an Acidic Tumor Microenvironment. Anal Chem 2021; 93:10411-10417. [PMID: 34279072 DOI: 10.1021/acs.analchem.1c02026] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
We report that microdroplet hydrogen-deuterium exchange (HDX) detected by desorption electrospray ionization mass spectrometry imaging (DESI-MSI) allows the measurement of the acidity of a tissue sample. The integration of HDX and DESI-MSI has been applied to visualize the acidic tumor microenvironment (TME). HDX-DESI-MSI enables the simultaneous collection of regional pH variation and its corresponding in-depth metabolomic changes. This technique is a cost-effective tool for providing insight into the pH-dependent tumor metabolism heterogeneity.
Collapse
Affiliation(s)
- Xiaowei Song
- Stanford University, Department of Chemistry, Stanford, California 94305, United States.,Department of Chemistry, Fudan University, Shanghai 200438, China
| | - Qingce Zang
- Institute of Materia Medica, Chinese Academy of Medical Science, Peking Union Medical College, Beijing 100050, China
| | - Richard N Zare
- Stanford University, Department of Chemistry, Stanford, California 94305, United States
| |
Collapse
|
13
|
Katagiri D, Wang F, Gore JC, Harris RC, Takahashi T. Clinical and experimental approaches for imaging of acute kidney injury. Clin Exp Nephrol 2021; 25:685-699. [PMID: 33835326 PMCID: PMC8154759 DOI: 10.1007/s10157-021-02055-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Accepted: 03/17/2021] [Indexed: 12/23/2022]
Abstract
Complex molecular cell dynamics in acute kidney injury and its heterogeneous etiologies in patient populations in clinical settings have revealed the potential advantages and disadvantages of emerging novel damage biomarkers. Imaging techniques have been developed over the past decade to further our understanding about diseased organs, including the kidneys. Understanding the compositional, structural, and functional changes in damaged kidneys via several imaging modalities would enable a more comprehensive analysis of acute kidney injury, including its risks, diagnosis, and prognosis. This review summarizes recent imaging studies for acute kidney injury and discusses their potential utility in clinical settings.
Collapse
Affiliation(s)
- Daisuke Katagiri
- Division of Nephrology and Hypertension, Vanderbilt University Medical Center, S-3223 MCN, Nashville, TN, 37232, USA.
- Department of Nephrology, National Center for Global Health and Medicine, 1-21-1 Toyama, Shinjuku-ku, Tokyo, 162-8655, Japan.
| | - Feng Wang
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
- Vanderbilt In Vivo Mouse Kidney Imaging Core, Vanderbilt University Medical Center, Nashville, TN, USA
| | - John C Gore
- Vanderbilt In Vivo Mouse Kidney Imaging Core, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Raymond C Harris
- Division of Nephrology and Hypertension, Vanderbilt University Medical Center, S-3223 MCN, Nashville, TN, 37232, USA
| | - Takamune Takahashi
- Division of Nephrology and Hypertension, Vanderbilt University Medical Center, S-3223 MCN, Nashville, TN, 37232, USA.
- Vanderbilt In Vivo Mouse Kidney Imaging Core, Vanderbilt University Medical Center, Nashville, TN, USA.
| |
Collapse
|
14
|
Caroli A, Remuzzi A, Lerman LO. Basic principles and new advances in kidney imaging. Kidney Int 2021; 100:1001-1011. [PMID: 33984338 DOI: 10.1016/j.kint.2021.04.032] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2021] [Revised: 04/21/2021] [Accepted: 04/22/2021] [Indexed: 12/12/2022]
Abstract
Over the past few years, clinical renal imaging has seen great advances, allowing assessments of kidney structure and morphology, perfusion, function and metabolism, and oxygenation, as well as microstructure and the interstitium. Medical imaging is becoming increasingly important in the evaluation of kidney physiology and pathophysiology, showing promise in management of patients with renal disease, in particular with regard to diagnosis, classification, and prediction of disease development and progression, monitoring response to therapy, detection of drug toxicity, and patient selection for clinical trials. A variety of imaging modalities, ranging from routine to advanced tools, are currently available to probe the kidney both spatially and temporally, particularly ultrasonography, computed tomography, positron emission tomography, renal scintigraphy, and multiparametric magnetic resonance imaging. Given that the range is broad and varied, kidney imaging techniques should be chosen based on the clinical question and the specific underlying pathologic mechanism, taking into account contraindications and possible adverse effects. Integration of various modalities providing complementary information will likely provide the greatest insight into renal pathophysiology. This review aims to highlight major recent advances in key tools that are currently available or potentially relevant for clinical kidney imaging, with a focus on non-oncological applications. The review also outlines the context of use, limitations, and advantages of various techniques, and highlights gaps to be filled with future development and clinical adoption.
Collapse
Affiliation(s)
- Anna Caroli
- Bioengineering Department, Istituto di Ricerche Farmacologiche Mario Negri IRCCS, Bergamo, Italy.
| | - Andrea Remuzzi
- Department of Management, Information and Production Engineering, University of Bergamo, Dalmine (Bergamo), Italy
| | - Lilach O Lerman
- Division of Nephrology and Hypertension, Mayo Clinic, Rochester, Minnesota, USA
| |
Collapse
|
15
|
Villano D, Romdhane F, Irrera P, Consolino L, Anemone A, Zaiss M, Dastrù W, Longo DL. A fast multislice sequence for 3D MRI-CEST pH imaging. Magn Reson Med 2020; 85:1335-1349. [PMID: 33031591 PMCID: PMC7756816 DOI: 10.1002/mrm.28516] [Citation(s) in RCA: 28] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Revised: 07/30/2020] [Accepted: 08/22/2020] [Indexed: 12/13/2022]
Abstract
Purpose Chemical exchange saturation transfer MRI can provide accurate pH images, but the slow scan time (due to long saturation periods and multiple offsets sampling) reduce both the volume coverage and spatial resolution capability, hence the possibility to interrogate the heterogeneity in tumors and organs. To overcome these limitations, we propose a fast multislice CEST‐MRI sequence with high pH accuracy and spatial resolution. Methods The sequence first uses a long saturation pulse to induce the steady‐state CEST contrast and a second short saturation pulse repeated after each image acquisition to compensate for signal losses based on an uneven irradiation scheme combined with a single‐shot rapid acquisition with refocusing echoes readout. Sequence sensitivity and accuracy in measuring pH was optimized by simulation and assessed by in vitro studies in pH‐varying phantoms. In vivo validation was performed in two applications by acquiring multislice pH images covering the whole tumors and kidneys after iopamidol injection. Results Simulated and in vivo data showed comparable contrast efficiency and pH responsiveness by reducing saturation time. The experimental data from a homogeneous, pH‐varying, iopamidol‐containing phantom show that the sequence produced a uniform CEST contrast across slices and accurate values across slices in less than 10 minutes. In vivo measurements allowed us to quantify the 3D pH gradients of tumors and kidneys, with pH ranges comparable with the literature. Conclusion The proposed fast multislice CEST‐MRI sequence allows volumetric acquisitions with good pH sensitivity, accuracy, and spatial resolution for several in vivo pH imaging applications.
Collapse
Affiliation(s)
- Daisy Villano
- Molecular Imaging Center, Department of Molecular Biotechnology and Health Sciences, University of Torino, Torino, Italy
| | - Feriel Romdhane
- Molecular Imaging Center, Department of Molecular Biotechnology and Health Sciences, University of Torino, Torino, Italy.,National Engineering School of Tunis (ENIT), University al Manar, Tunis, Tunisia
| | - Pietro Irrera
- Molecular Imaging Center, Department of Molecular Biotechnology and Health Sciences, University of Torino, Torino, Italy.,Institute of Biostructures and Bioimaging, University of Campania "Luigi Vanvitelli," Italian National Research Council, Napoli, Italy
| | - Lorena Consolino
- Molecular Imaging Center, Department of Molecular Biotechnology and Health Sciences, University of Torino, Torino, Italy
| | - Annasofia Anemone
- Molecular Imaging Center, Department of Molecular Biotechnology and Health Sciences, University of Torino, Torino, Italy
| | - Moritz Zaiss
- Department of Neuroradiology, Friedrich-Alexander Universität Erlangen-Nürnberg, University Hospital Erlangen, Erlangen, Germany
| | - Walter Dastrù
- Molecular Imaging Center, Department of Molecular Biotechnology and Health Sciences, University of Torino, Torino, Italy
| | - Dario Livio Longo
- Institute of Biostructures and Bioimaging, Italian National Research Council, Torino, Italy
| |
Collapse
|