1
|
Nemati SS, Dehghan G, Soleymani J, Jouyban A. Advances in electrochemical sensors for naproxen detection: Mechanisms, performance factors, and emerging challenges. Heliyon 2025; 11:e40906. [PMID: 39758385 PMCID: PMC11699440 DOI: 10.1016/j.heliyon.2024.e40906] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2024] [Revised: 12/03/2024] [Accepted: 12/03/2024] [Indexed: 01/07/2025] Open
Abstract
Naproxen (NAP), a nonsteroidal anti-inflammatory, analgesic, and antipyretic drug, has fewer side effects than similar drugs due to its aryl acetic acid structure. For this reason, it is widely prescribed to manage fever, short-term and long-term pain, and musculoskeletal disorders. However, its use has complications such as changes in kidney function, severe gastrointestinal lesions, and increased bleeding after surgery. In addition, the toxicity of NAP or its metabolites affects the organisms in the ecosystem. Therefore, it is necessary to determine the pharmaceutical quality of produced NAP and measure its amount in living organisms and the environment. Spectroscopy, chromatography, and electrochemical methods have been used to determine NAP. Electrochemical methods have attracted more attention due to their low cost, easy sample preparation, availability, sensitivity, and acceptable results. In addition, using nanomaterials for NAP oxidation results in high surface-to-volume, high available active sites, low cost, and long-term usability with high sensitivity. In this review, electrochemical-based methods for NAP analysis and sensing have been reviewed. Also, the influential factors in NAP identification and evaluation, and their oxidation mechanism have been discussed.
Collapse
Affiliation(s)
- Seyed Saman Nemati
- Laboratory of Biochemistry and Molecular Biology, Department of Biology, Faculty of Natural Sciences, University of Tabriz, 51666-16471, Tabriz, Iran
| | - Gholamreza Dehghan
- Laboratory of Biochemistry and Molecular Biology, Department of Biology, Faculty of Natural Sciences, University of Tabriz, 51666-16471, Tabriz, Iran
| | - Jafar Soleymani
- Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Abolghasem Jouyban
- Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
- Faculty of Pharmacy, Near East University, PO BOX: 99138 Nicosia, North Cyprus, Mersin, 10, Turkey
| |
Collapse
|
2
|
Wang R, He B, Wang Y, Liu Y, Liang Z, Jin H, Wei M, Ren W, Suo Z, Xu Y. A novel electrochemical aptasensor based on AgPdNPs/PEI-GO and hollow nanobox-like Pt@Ni-CoHNBs for procymidone detection. Bioelectrochemistry 2024; 158:108728. [PMID: 38733721 DOI: 10.1016/j.bioelechem.2024.108728] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2024] [Revised: 05/06/2024] [Accepted: 05/07/2024] [Indexed: 05/13/2024]
Abstract
Herein, an aptasensor based on a signal amplification strategy was developed for the sensitive detection of procymidone (PCM). AgPd nanoparticles/Polenimine Graphite oxide (AgPdNPs/PEI-GO) was weaned as electrode modification material to facilitate electron transport and increase the active sites on the electrode surface. Besides, Pt@Ni-Co nanoboxes (Pt@Ni-CoHNBs) were utilized to be carriers for signaling tags, after hollowing ZIF-67 and growing Pt, the resulting Pt@Ni-CoHNBs has a tremendous amounts of folds occurred on the surface, enables it to carry a larger quantity of thionine, thus amplify the detectable electrochemical signal. In the presence of PCM, the binding of PCM to the signal probe would trigger a change in electrical signal. The aptasensor was demonstrated with excellent sensitivity and a low detection limit of 0.98 pg·mL-1, along with a wide linear range of 1 μg·mL-1 to 1 pg·mL-1. Meanwhile, the specificity, stability and reproducibility of the constructed aptasensor were proved to be satisfactory.
Collapse
Affiliation(s)
- Ruonan Wang
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, PR China
| | - Baoshan He
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, PR China.
| | - Yuling Wang
- School of Natural Sciences, Macquarie University, Sydney, NSW 2109, Australia
| | - Yao Liu
- Henan Scientific Research Platform Service Center, Zhengzhou, Henan 450003, PR China
| | - Zhengyong Liang
- School of Chemical Engineering, Zhengzhou University, Zhengzhou, Henan 450001, PR China
| | - Huali Jin
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, PR China
| | - Min Wei
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, PR China
| | - Wenjie Ren
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, PR China
| | - Zhiguang Suo
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, PR China
| | - Yiwei Xu
- School of Food Science and Technology, Henan University of Technology, Zhengzhou, Henan 450001, PR China
| |
Collapse
|
3
|
Robby AI, Jiang S, Jin EJ, Park SY. Coenzyme-A-Responsive Nanogel-Coated Electrochemical Sensor for Osteoarthritis-Detection-Based Genetic Models. Gels 2024; 10:451. [PMID: 39057474 PMCID: PMC11276253 DOI: 10.3390/gels10070451] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2024] [Revised: 07/01/2024] [Accepted: 07/08/2024] [Indexed: 07/28/2024] Open
Abstract
An electrochemical sensor sensitive to coenzyme A (CoA) was designed using a CoA-responsive polyallylamine-manganese oxide-polymer dot nanogel coated on the electrode surface to detect various genetic models of osteoarthritis (OA). The CoA-responsive nanogel sensor responded to the abundance of CoA in OA, causing the breakage of MnO2 in the nanogel, thereby changing the electroconductivity and fluorescence of the sensor. The CoA-responsive nanogel sensor was capable of detecting CoA depending on the treatment time and distinguishing the response towards different OA genetic models that contained different levels of CoA (wild type/WT, NudT7 knockout/N7KO, and Acot12 knockout/A12KO). The WT, N7KO, and A12KO had distinct resistances, which further increased as the incubation time were changed from 12 h (R12h = 2.11, 2.40, and 2.68 MΩ, respectively) to 24 h (R24h = 2.27, 2.59, and 2.92 MΩ, respectively) compared to the sensor without treatment (Rcontrol = 1.63 MΩ). To simplify its application, the nanogel sensor was combined with a wireless monitoring device to allow the sensing data to be directly transmitted to a smartphone. Furthermore, OA-indicated anabolic (Acan) and catabolic (Adamts5) factor transcription levels in chondrocytes provided evidence regarding CoA and nanogel interactions. Thus, this sensor offers potential usage in simple and sensitive OA diagnostics.
Collapse
Affiliation(s)
- Akhmad Irhas Robby
- Chemical Industry Institute, Korea National University of Transportation, Chungju 27469, Chungcheongbuk-do, Republic of Korea;
- Department of Chemical & Biological Engineering, Korea National University of Transportation, Chungju 27469, Chungcheongbuk-do, Republic of Korea
| | - Songling Jiang
- Integrated Omics Institute, Wonkwang University, Iksan 54538, Jeonbuk, Republic of Korea;
| | - Eun-Jung Jin
- Integrated Omics Institute, Wonkwang University, Iksan 54538, Jeonbuk, Republic of Korea;
- Department of Biological Sciences, College of Health Sciences, Wonkwang University, Iksan 54538, Jeonbuk, Republic of Korea
| | - Sung Young Park
- Chemical Industry Institute, Korea National University of Transportation, Chungju 27469, Chungcheongbuk-do, Republic of Korea;
- Department of Chemical & Biological Engineering, Korea National University of Transportation, Chungju 27469, Chungcheongbuk-do, Republic of Korea
| |
Collapse
|
4
|
Ahsani MK, Ahour F, Asghari E. Development of isoniazid electrochemical sensor using nickel ferrite - nitrogen and sulfur co-doped graphene quantum dot nanocomposite as a new electrode modifier. Sci Rep 2024; 14:14228. [PMID: 38902392 PMCID: PMC11189936 DOI: 10.1038/s41598-024-64797-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2024] [Accepted: 06/13/2024] [Indexed: 06/22/2024] Open
Abstract
This work reports the synthesis of nickel ferrite decorated nitrogen and sulfur co-doped graphene quantum dot (NF@N, S:GQD) and its use as an electrode modifier. The developed NF@N, S:GQD modified glassy carbon electrode (NF@N, S:GQD/GCE) was applied to assess isoniazid (INZ) concentration based on its oxidation at the surface of the proposed electrode. Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) were used as appropriate electrochemical techniques to study the electrochemical behavior of INZ and determine it. Based on combined evidence from surveys, research, and personal results, it is thought that the combination of nickel ferrite and doped graphene quantum dots can synergistically affect results, leading to increased sensitivity and reduced detection limits. This is probably mainly due to the high electrical conductivity of N, S-GQD structure, the electrocatalytic effect of nickel ferrite, and increased surface area resulting from the nano size of the modifier. The optimum conditions for preparing of the modified electrode and determination of INZ are selected by performing electrochemical experiments. The voltammetric response of the sensor is linear from 0.3 to 40 nM INZ under optimal conditions and the detection limit of the sensor is 0.1 nM. The validity and performance of the prepared sensor were confirmed by determining the amount of INZ in the drug and urine as real samples. The composite of doped nanoparticles and nickel ferrite is an innovative modification material to create electrochemical sensors with high sensitivity and selectivity that can be used in pharmaceutical applications.
Collapse
Affiliation(s)
- Mohammad Kazem Ahsani
- Department of Physical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
| | - Fatemeh Ahour
- Nanotechnology Research Group, Faculty of Chemistry, Urmia University, Urmia, Iran.
- Department of Nanochemistry, Nanotechnology Research Center, Urmia University, Urmia, Iran.
| | - Elnaz Asghari
- Department of Physical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
| |
Collapse
|
5
|
Svigelj R, Toniolo R, Bertoni C, Fraleoni-Morgera A. Synergistic Applications of Graphene-Based Materials and Deep Eutectic Solvents in Sustainable Sensing: A Comprehensive Review. SENSORS (BASEL, SWITZERLAND) 2024; 24:2403. [PMID: 38676019 PMCID: PMC11054382 DOI: 10.3390/s24082403] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 03/19/2024] [Accepted: 04/04/2024] [Indexed: 04/28/2024]
Abstract
The recently explored synergistic combination of graphene-based materials and deep eutectic solvents (DESs) is opening novel and effective avenues for developing sensing devices with optimized features. In more detail, remarkable potential in terms of simplicity, sustainability, and cost-effectiveness of this combination have been demonstrated for sensors, resulting in the creation of hybrid devices with enhanced signal-to-noise ratios, linearities, and selectivity. Therefore, this review aims to provide a comprehensive overview of the currently available scientific literature discussing investigations and applications of sensors that integrate graphene-based materials and deep eutectic solvents, with an outlook for the most promising developments of this approach.
Collapse
Affiliation(s)
- Rossella Svigelj
- Department of Agrifood, Environmental and Animal Sciences, University of Udine, 33100 Udine, Italy
| | - Rosanna Toniolo
- Department of Agrifood, Environmental and Animal Sciences, University of Udine, 33100 Udine, Italy
| | | | | |
Collapse
|
6
|
Alamro FS, Hefnawy MA, Nafee SS, Al-Kadhi NS, Pashameah RA, Ahmed HA, Medany SS. Chitosan Supports Boosting NiCo 2O 4 for Catalyzed Urea Electrochemical Removal Application. Polymers (Basel) 2023; 15:3058. [PMID: 37514447 PMCID: PMC10384518 DOI: 10.3390/polym15143058] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Revised: 07/05/2023] [Accepted: 07/12/2023] [Indexed: 07/30/2023] Open
Abstract
Currently, wastewater containing high urea levels poses a significant risk to human health. Else, electrocatalytic methodologies have the potential to transform urea present in urea-rich wastewater into hydrogen, thereby contributing towards environmental conservation and facilitating the production of sustainable energy. The characterization of the NiCo2O4@chitosan catalyst was performed by various analytical techniques, including scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). Furthermore, the activity of electrodes toward urea removal was investigated by several electrochemical techniques. As a function of current density, the performance of the modified NiCo2O4@chitosan surface was employed to remove urea using electrochemical oxidation. Consequently, the current density measurement was 43 mA cm-2 in a solution of 1.0 M urea and 1.0 M KOH. Different kinetic characteristics were investigated, including charge transfer coefficient (α), Tafel slope (29 mV dec-1), diffusion coefficient (1.87 × 10-5 cm2 s-1), and surface coverage 4.29 × 10-9 mol cm-2. The electrode showed high stability whereas it lost 10.4% of its initial current after 5 h of urea oxidation.
Collapse
Affiliation(s)
- Fowzia S. Alamro
- Department of Chemistry, College of Science, Princess Nourah Bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia
| | - Mahmoud A. Hefnawy
- Chemistry Department, Faculty of Science, Cairo University, Giza 12613, Egypt
| | - Sherif S. Nafee
- Physics Department, Faculty of Science, King Abdulaziz University, Jeddah 21589, Saudi Arabia
| | - Nada S. Al-Kadhi
- Department of Chemistry, College of Science, Princess Nourah Bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia
| | - Rami Adel Pashameah
- Department of Chemistry, Faculty of Applied Science, Umm Al-Qura University, Makkah 24230, Saudi Arabia
| | - Hoda A. Ahmed
- Chemistry Department, Faculty of Science, Cairo University, Giza 12613, Egypt
- Chemistry Department, College of Sciences, Taibah University, Yanbu 30799, Saudi Arabia
| | - Shymaa S. Medany
- Chemistry Department, Faculty of Science, Cairo University, Giza 12613, Egypt
| |
Collapse
|
7
|
Saleh HM, Hassan AI. Synthesis and Characterization of Nanomaterials for Application in Cost-Effective Electrochemical Devices. SUSTAINABILITY 2023; 15:10891. [DOI: 10.3390/su151410891] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/10/2025]
Abstract
Nanomaterials have gained significant attention as a remarkable class of materials due to their unique properties and the fact that they encompass a wide range of samples with at least one dimension ranging from 1 to 100 nm. The deliberate design of nanoparticles enables the achievement of extremely large surface areas. In the field of cost-effective electrochemical devices for energy storage and conversion applications, nanomaterials have emerged as a key area of research. Their exceptional physical and chemical properties have led to extensive investigations aimed at improving the performance and cost-effectiveness of electrochemical devices, including batteries, supercapacitors, and fuel cells. The continuous development and enhancement of these high-performance materials are driven by the demand for enhanced productivity, connectivity, and sustainability at a reduced cost. This review focuses on the electrochemical performance of electrodes, energy storage, and electrochemical sensors (ES) based on nanotechnology. It discusses the application of nanotechnology in electrochemistry for water purification and the fate of substances in water, while also introducing green nanotechnology and cost-effective, high-fidelity product creation through electrochemical methods. The study emphasizes the synthesis of novel nanomaterials, such as metal–organic frameworks (MOFs), covalent organic frameworks (COFs), and MXenes, with applications in electrochemical devices. Furthermore, it explores the integration of nanostructures with electrochemical systems in economically significant and future applications, along with the challenges faced by nanotechnology-based industries. The paper also explores the interplay between nanomaterials and biosensors, which play a vital role in electrochemical devices. Overall, this review provides a comprehensive overview of the significance of nanomaterials in the development of cost-effective electrochemical devices for energy storage and conversion. It highlights the need for further research in this rapidly evolving field and serves as a valuable resource for researchers and engineers interested in the latest advancements in nanomaterials for electrochemical devices.
Collapse
Affiliation(s)
- Hosam M. Saleh
- Radioisotope Department, Nuclear Research Center, Egyptian Atomic Energy Authority, Cairo 11787, Egypt
| | - Amal I. Hassan
- Radioisotope Department, Nuclear Research Center, Egyptian Atomic Energy Authority, Cairo 11787, Egypt
| |
Collapse
|
8
|
Karishma BR, Manasa G, Bhakta AK, Maiyalagan T, Mascarenhas RJ, Shetti NP. Electrocatalytic barium-oxide decorated MWCNT amperometric sensor for the quantification of anesthetic drug Procaine. Colloids Surf B Biointerfaces 2023; 227:113363. [PMID: 37269576 DOI: 10.1016/j.colsurfb.2023.113363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2023] [Revised: 05/14/2023] [Accepted: 05/21/2023] [Indexed: 06/05/2023]
Abstract
Procaine hydrochloride (P.HCl) is one of the earliest and most well-established local anesthetic drugs used in medicine. Though it is employed frequently for effective clinical nerve blocks during surgeries, its immoderate administration has often shown reports of systemic toxicity. To prevent such repercussions, developing a sensor for the drug is crucial to enable real-time monitoring of the drug and assist in quality control procedures during its industrial preparations. Thus, in this work, we have fabricated a simple yet highly selective and sensitive amperometric sensor for P.HCl detection based on a Barium-oxide multi-wall carbon nanotube-modified carbon paste electrode (BaO-MWCNT/CPE). Herein, we have adopted a novel approach devoid of sophisticated procedures and pretreatments for rapidly determining P.HCl. Furthermore, experimental conditions, including supporting electrolytes, pH, and scan rate, were optimized to achieve a well-defined P.HCl anodic peak current at 631 mV, which is lower than the previously reported peak potentials, indicating an advantage of reduced overpotential. Besides, a striking 66-fold rise in current responsiveness to P.HCl was achieved upon modification with BaO-MWCNT. Such an intense signal enhancement upon electrode modification compared to bare CPE was due to the strong electrocatalytic feature of BaO-MWCNT, which was verified using surface morphology studies with scanning electron microscopy (FESEM) and transmission electron microscopy (TEM). Additionally, the charge transfer kinetics analyzed via electrochemical impedance spectroscopy (EIS) justified the enhancement of electrocatalytic activity upon electrode modification. The developed sensor exhibited a remarkable analytical performance over a wide linear dynamic range of 2.0-100.0 µM with a detection limit of 0.14 µM. Moreover, a significant merit of this sensor is its excellent selectivity towards P.HCl even in the presence of various common interferants. Finally, the versatility of the sensor was further validated by implementing it for the trace analysis of urine and blood serum real samples.
Collapse
Affiliation(s)
- B R Karishma
- Electrochemistry Research Group, St. Joseph's University, Lalbagh Road, Bengaluru 560027, Karnataka, India
| | - G Manasa
- Electrochemistry Research Group, St. Joseph's University, Lalbagh Road, Bengaluru 560027, Karnataka, India
| | - Arvind K Bhakta
- Electrochemistry Research Group, St. Joseph's University, Lalbagh Road, Bengaluru 560027, Karnataka, India
| | - T Maiyalagan
- Electrochemical Energy Laboratory, Department of Chemistry, SRM Institute of Science and Technology, Kattankulathur 603203, Tamil Nadu, India
| | - Ronald J Mascarenhas
- Electrochemistry Research Group, St. Joseph's University, Lalbagh Road, Bengaluru 560027, Karnataka, India.
| | - Nagaraj P Shetti
- Center for Energy and Environment, School of Advanced Sciences, KLE Technological University, Vidyanagar, Hubballi 580031, Karnataka, India; University Center for Research & Development (UCRD), Chandigarh University, Gharuan, Mohali 140413, Punjab, India.
| |
Collapse
|
9
|
Bonart H, Gebhard F, Hecht L, Roy T, Liebchen B, Hardt S. Detecting Isotachophoresis Zones Hidden in Noise Using Signal Processing. Anal Chem 2023; 95:7575-7583. [PMID: 37133530 DOI: 10.1021/acs.analchem.3c00321] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Lowering the limit of detection in chemical or biochemical analysis is key to extending the application scope of sensing schemes. Usually, this is related to an increased instrumentation effort, which in turn precludes many commercial applications. We demonstrate that the signal-to-noise ratio of isotachophoresis-based microfluidic sensing schemes can be substantially increased merely by postprocessing of recorded signals. This becomes possible by exploiting knowledge about the physics of the underlying measurement process. The implementation of our method is based on microfluidic isotachophoresis and fluorescence detection, for which we take advantage of the physics of electrophoretic sample transport and the structure of noise in the imaging process. We demonstrate that by processing only 200 images, the detectable concentration, compared to the detection from a single image, is already lowered by 2 orders of magnitude without any additional instrumentation effort. Furthermore, we show that the signal-to-noise ratio is proportional to the square root of the number of fluorescence images, which leaves room for further lowering of the detection limit. In the future, our results could be relevant for various applications where the detection of minute sample amounts plays a role.
Collapse
Affiliation(s)
- Henning Bonart
- Technische Universität Darmstadt, Department of Mechanical Engineering, Institute for Nano- and Microfluidics, Alarich-Weiss-Straße 10, 64287 Darmstadt, Germany
- Technische Universität Darmstadt, Center for Computational Engineering, Dolivostraße 15, 64293 Darmstadt, Germany
| | - Florian Gebhard
- Technische Universität Darmstadt, Department of Mechanical Engineering, Institute for Nano- and Microfluidics, Alarich-Weiss-Straße 10, 64287 Darmstadt, Germany
| | - Lukas Hecht
- Technische Universität Darmstadt, Department of Physics, Institute for Condensed Matter Physics, Hochschulstraße 8, 64289 Darmstadt, Germany
| | - Tamal Roy
- Technische Universität Darmstadt, Department of Mechanical Engineering, Institute for Nano- and Microfluidics, Alarich-Weiss-Straße 10, 64287 Darmstadt, Germany
- Eidgenössische Technische Hochschule Zürich, Department of Mechanical and Process Engineering, Sonneggstrasse 3, Zurich 8092, Switzerland
| | - Benno Liebchen
- Technische Universität Darmstadt, Department of Physics, Institute for Condensed Matter Physics, Hochschulstraße 8, 64289 Darmstadt, Germany
| | - Steffen Hardt
- Technische Universität Darmstadt, Department of Mechanical Engineering, Institute for Nano- and Microfluidics, Alarich-Weiss-Straße 10, 64287 Darmstadt, Germany
| |
Collapse
|
10
|
Manaf BAA, Hong SP, Rizwan M, Arshad F, Gwenin C, Ahmed MU. Recent advancement in sensitive detection of carcinoembryonic antigen using nanomaterials based immunosensors. SURFACES AND INTERFACES 2023; 36:102596. [DOI: 10.1016/j.surfin.2022.102596] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|
11
|
Truong PL, Yin Y, Lee D, Ko SH. Advancement in COVID-19 detection using nanomaterial-based biosensors. EXPLORATION (BEIJING, CHINA) 2023; 3:20210232. [PMID: 37323622 PMCID: PMC10191025 DOI: 10.1002/exp.20210232] [Citation(s) in RCA: 20] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/06/2021] [Accepted: 05/11/2022] [Indexed: 06/17/2023]
Abstract
Coronavirus disease 2019 (COVID-19) pandemic has exemplified how viral growth and transmission are a significant threat to global biosecurity. The early detection and treatment of viral infections is the top priority to prevent fresh waves and control the pandemic. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been identified through several conventional molecular methodologies that are time-consuming and require high-skill labor, apparatus, and biochemical reagents but have a low detection accuracy. These bottlenecks hamper conventional methods from resolving the COVID-19 emergency. However, interdisciplinary advances in nanomaterials and biotechnology, such as nanomaterials-based biosensors, have opened new avenues for rapid and ultrasensitive detection of pathogens in the field of healthcare. Many updated nanomaterials-based biosensors, namely electrochemical, field-effect transistor, plasmonic, and colorimetric biosensors, employ nucleic acid and antigen-antibody interactions for SARS-CoV-2 detection in a highly efficient, reliable, sensitive, and rapid manner. This systematic review summarizes the mechanisms and characteristics of nanomaterials-based biosensors for SARS-CoV-2 detection. Moreover, continuing challenges and emerging trends in biosensor development are also discussed.
Collapse
Affiliation(s)
- Phuoc Loc Truong
- Laser and Thermal Engineering LabDepartment of Mechanical EngineeringGachon UniversitySeongnamKorea
| | - Yiming Yin
- New Materials InstituteDepartment of MechanicalMaterials and Manufacturing EngineeringUniversity of Nottingham Ningbo ChinaNingboChina
- Applied Nano and Thermal Science LabDepartment of Mechanical EngineeringSeoul National UniversityGwanak‐guSeoulKorea
| | - Daeho Lee
- Laser and Thermal Engineering LabDepartment of Mechanical EngineeringGachon UniversitySeongnamKorea
| | - Seung Hwan Ko
- Applied Nano and Thermal Science LabDepartment of Mechanical EngineeringSeoul National UniversityGwanak‐guSeoulKorea
- Institute of Advanced Machinery and Design (SNU‐IAMD)/Institute of Engineering ResearchSeoul National UniversityGwanak‐guSeoulKorea
| |
Collapse
|
12
|
Engineered Nanomaterial based Implantable MicroNanoelectrode for in vivo Analysis: Technological Advancement and Commercial Aspects. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
13
|
Kavacık M, Kilic MS. Square wave voltammetric detection of cholesterol with biosensor based on poly(styrene--ε-caprolactone)/MWCNTs composite. Biotechnol Appl Biochem 2022. [PMID: 36585847 DOI: 10.1002/bab.2427] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2022] [Accepted: 12/03/2022] [Indexed: 01/01/2023]
Abstract
A novel poly(styrene--ε-caprolactone)/multiwalled carbon nanotubes/cholesterol oxidase film-coated glassy carbon electrode was designed for cholesterol detection by square wave voltammetry (SWV). The biosensor responded to cholesterol with a measurement concentration range between 1 and 130 μM, a relative standard deviation of only 0.095% and accuracy of 100.42% ±2.85 with the SWV technique in the potential range from -0.6 to +0.6 V. The limit of detection was calculated to be 0.63 μM. The biosensor was preserved 91 and 84% of its initial response at the end of the 9st and 25st days, respectively. Human serum from human male AB plasma was analyzed without pretreatment except for dilution to investigate the performance of the biosensor in a complex medium.
Collapse
Affiliation(s)
- Mehmet Kavacık
- Department of Biomedical Engineering, Zonguldak Bülent Ecevit University, Zonguldak, Turkey
| | - Muhammet Samet Kilic
- Department of Biomedical Engineering, Zonguldak Bülent Ecevit University, Zonguldak, Turkey
| |
Collapse
|
14
|
Kanjwal MA, Ghaferi AA. Graphene Incorporated Electrospun Nanofiber for Electrochemical Sensing and Biomedical Applications: A Critical Review. SENSORS (BASEL, SWITZERLAND) 2022; 22:8661. [PMID: 36433257 PMCID: PMC9697565 DOI: 10.3390/s22228661] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Revised: 10/27/2022] [Accepted: 11/03/2022] [Indexed: 06/16/2023]
Abstract
The extraordinary material graphene arrived in the fields of engineering and science to instigate a material revolution in 2004. Graphene has promptly risen as the super star due to its outstanding properties. Graphene is an allotrope of carbon and is made up of sp2-bonded carbon atoms placed in a two-dimensional honeycomb lattice. Graphite consists of stacked layers of graphene. Due to the distinctive structural features as well as excellent physico-chemical and electrical conductivity, graphene allows remarkable improvement in the performance of electrospun nanofibers (NFs), which results in the enhancement of promising applications in NF-based sensor and biomedical technologies. Electrospinning is an easy, economical, and versatile technology depending on electrostatic repulsion between the surface charges to generate fibers from the extensive list of polymeric and ceramic materials with diameters down to a few nanometers. NFs have emerged as important and attractive platform with outstanding properties for biosensing and biomedical applications, because of their excellent functional features, that include high porosity, high surface area to volume ratio, high catalytic and charge transfer, much better electrical conductivity, controllable nanofiber mat configuration, biocompatibility, and bioresorbability. The inclusion of graphene nanomaterials (GNMs) into NFs is highly desirable. Pre-processing techniques and post-processing techniques to incorporate GNMs into electrospun polymer NFs are precisely discussed. The accomplishment and the utilization of NFs containing GNMs in the electrochemical biosensing pathway for the detection of a broad range biological analytes are discussed. Graphene oxide (GO) has great importance and potential in the biomedical field and can imitate the composition of the extracellular matrix. The oxygen-rich GO is hydrophilic in nature and easily disperses in water, and assists in cell growth, drug delivery, and antimicrobial properties of electrospun nanofiber matrices. NFs containing GO for tissue engineering, drug and gene delivery, wound healing applications, and medical equipment are discussed. NFs containing GO have importance in biomedical applications, which include engineered cardiac patches, instrument coatings, and triboelectric nanogenerators (TENGs) for motion sensing applications. This review deals with graphene-based nanomaterials (GNMs) such as GO incorporated electrospun polymeric NFs for biosensing and biomedical applications, that can bridge the gap between the laboratory facility and industry.
Collapse
|
15
|
Sawkar RR, Shanbhag MM, Tuwar SM, Mondal K, Shetti NP. Sodium Dodecyl Sulfate-Mediated Graphene Sensor for Electrochemical Detection of the Antibiotic Drug: Ciprofloxacin. MATERIALS (BASEL, SWITZERLAND) 2022; 15:7872. [PMID: 36431357 PMCID: PMC9696905 DOI: 10.3390/ma15227872] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/18/2022] [Revised: 10/28/2022] [Accepted: 11/02/2022] [Indexed: 06/16/2023]
Abstract
The present study involves detecting and determining CIP by a new electrochemical sensor based on graphene (Gr) in the presence of sodium dodecyl sulfate (SDS) employing voltammetric techniques. Surface morphology studies of the sensing material were analyzed using a scanning electron microscope (SEM) and atomic force microscope (AFM). In the electroanalysis of CIP at the developed electrode, an enhanced anodic peak response was recorded, suggesting the electro-oxidation of CIP at the electrode surface. Furthermore, we evaluated the impact of the electrolytic solution, scan rate, accumulation time, and concentration variation on the electrochemical behavior of CIP. The possible electrode mechanism was proposed based on the acquired experimental information. A concentration variation study was performed using differential pulse voltammetry (DPV) in the lower concentration range, and the fabricated electrode achieved a detection limit of 2.9 × 10-8 M. The proposed sensor detected CIP in pharmaceutical and biological samples. The findings displayed good recovery, with 93.8% for tablet analysis and 93.3% to 98.7% for urine analysis. The stability of a developed electrode was tested by inter- and intraday analysis.
Collapse
Affiliation(s)
- Rakesh R. Sawkar
- Department of Chemistry, Karnatak Science College, Dharwad 580001, Karnataka, India
| | - Mahesh M. Shanbhag
- Department of Chemistry, K.L.E. Institute of Technology, Hubballi 580027, Karnataka, India
| | - Suresh M. Tuwar
- Department of Chemistry, Karnatak Science College, Dharwad 580001, Karnataka, India
| | - Kunal Mondal
- Idaho National Laboratory, Idaho Falls, ID 83415, USA
- Department of Civil & Environmental Engineering, Idaho State University, Pocatello, ID 83209, USA
| | - Nagaraj P. Shetti
- Department of Chemistry, School of Advanced Sciences, KLE Technological University, Vidyanagar, Hubballi 580031, Karnataka, India
- University Center for Research & Development (UCRD), Chandigarh University, Gharuan, Mohali 140413, Punjab, India
| |
Collapse
|
16
|
Karimian R, Afshar V. Electrochemical determination of purine and pyrimidine bases using a 1,10-phenanthroline-Fe 3O 4 nanoparticles-graphene oxide-chitosan nanocomposite. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:3790-3797. [PMID: 36124906 DOI: 10.1039/d2ay01069k] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
A 1,10-phenanthroline-Fe3O4 nanoparticles-graphene oxide-chitosan nanocomposite (Phen-Fe3O4 NPs-GO-Chi) was fabricated and used to modify a glassy carbon (GC) electrode. The modified surface of the electrode was characterized by field emission-scanning electrochemical microscopy. Then, the prepared electrode was used as a sensor for simultaneous determination of purine and pyrimidine bases in DNA. The Phen-Fe3O4 NPs-GO-Chi composite modified electrode showed excellent response toward guanine (G), adenine (A), thymine (T) and cytosine (C). The sensor displayed higher effective surface, an appropriate peak-to-peak separation, and a larger peak current compared to the bare electrode. The evaluated detection limits of G, A, T, and C concentrations are 12, 4, 22, and 9 μM over the concentration range of 15-500, 15-400, 40-1000 and 40-1400 μM, respectively. In addition, the results show that the modified electrode is stable for 7 days and has good repeatability and interfering molecules and ions have no significant effect on peak current. The proposed method was successfully applied for the determination of purine and pyrimidine bases in a fish DNA sperm sample as a real sample.
Collapse
Affiliation(s)
- Ramin Karimian
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran.
| | - Vahid Afshar
- Chemical Injuries Research Center, Systems Biology and Poisonings Institute, Baqiyatallah University of Medical Sciences, Tehran, Iran.
| |
Collapse
|
17
|
Abstract
Zileuton (ZLT) is an active oral inhibitor of enzyme 5-lipoxygenase, and long-term intake and overdose of ZLT cause adverse effects, leading to critical conditions in patients. This is a well-recognized issue that necessitates a better approach for ZLT sensing. Given the increasing interest in ZLT sensing and the limitations of previous techniques, there is a need for a highly sensitive, robust, and fast operation method that is inexpensive and easy to use. Thus, for the sensitive detection and determination of ZLT, an electrochemical sensor based on graphene was fabricated. Graphene has excellent properties, such as high surface area, low toxicity, conductivity, and electroactive conjugation with biomolecules, making it suitable for sensing. The electrocatalytic property of graphene promotes the redox-coupled reaction of ZLT. Electrochemical investigation of the modifier was carried out by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). An optimization and analysis of the influence of different parameters on the electrochemical behavior of ZLT were carried out using the CV approach. The scan rate study aided in exploring the physicochemical properties of the electrode process, and two electrons with two protons were found to be involved in the electrooxidation of ZLT. The fabricated sensor showed a wide range of linearity with ZLT, from 0.3 µM to 100.0 µM, and the detection limit was evaluated as 0.03 µM under optimized conditions. The analysis of spiked urine samples, with good recovery values for percent RSD, provided support for the efficiency and applicability of the developed electrode.
Collapse
|
18
|
Shanbhag YM, Shanbhag MM, Malode SJ, Dhanalakshmi S, Mondal K, Shetti NP. Direct and Sensitive Electrochemical Evaluation of Pramipexole Using Graphitic Carbon Nitride (gCN) Sensor. BIOSENSORS 2022; 12:bios12080552. [PMID: 35892449 PMCID: PMC9394362 DOI: 10.3390/bios12080552] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 07/19/2022] [Accepted: 07/19/2022] [Indexed: 12/31/2022]
Abstract
Pramipexole (PMXL) belongs to the benzothiazole class of aromatic compounds and is used in treating Parkinson’s disease; however, overdosage leads to some abnormal effects that could trigger severe side effects. Therefore, it demands a sensitive analytical tool for trace level detection. In this work, we successfully developed an electrochemical sensor for the trace level detection of PMXL, using the voltammetric method. For the analysis, graphitic carbon nitride (gCN) was opted and synthesized by using a high-temperature thermal condensation method. The synthesized nanoparticles were employed for surface characterization, using transmission electron microscopy (TEM), X-ray diffraction (XRD), and atomic force microscopy (AFM) techniques. The electrochemical characterization of the material was evaluated by using the electrochemical impedance spectroscopy (EIS) technique to evaluate the solution–electrode interface property. The cyclic voltammetry (CV) behavior of PMXL displayed an anodic peak in the forward scan, indicating that PMXL underwent electrooxidation, and an enhanced detection peak with lower detection potential was achieved for gCN-modified carbon paste electrode (gCN·CPE). The influence of different parameters on the electrochemical behavior was analyzed, revealing the diffusion governing the electrode process with an equal number of hydronium ions and electron involvement. For the fabricated gCN·CPE, good linearity range was noticed from 0.05 to 500 µM, and a lower detection limit (LD) of 0.012 µM was achieved for the selected concentration range (0.5 to 30 µM). Selectivity of the electrode in PMXL detection was investigated by conducting an interference study, while the tablet sample analysis demonstrates the sensitive and real-time application of the electrode. The good recovery values for the analysis illustrate the efficiency of the electrode for PMXL analysis.
Collapse
Affiliation(s)
- Yogesh M. Shanbhag
- Department of Chemistry, School of Advanced Sciences, KLE Technological University, Vidyanagar, Hubballi 580 031, Karnataka, India; (Y.M.S.); (S.J.M.); (S.D.)
| | - Mahesh M. Shanbhag
- Department of Chemistry, K.L.E. Institute of Technology, Hubballi 580 027, Karnataka, India;
| | - Shweta J. Malode
- Department of Chemistry, School of Advanced Sciences, KLE Technological University, Vidyanagar, Hubballi 580 031, Karnataka, India; (Y.M.S.); (S.J.M.); (S.D.)
| | - S. Dhanalakshmi
- Department of Chemistry, School of Advanced Sciences, KLE Technological University, Vidyanagar, Hubballi 580 031, Karnataka, India; (Y.M.S.); (S.J.M.); (S.D.)
| | - Kunal Mondal
- Idaho National Laboratory, Idaho Falls, ID 83415, USA
- Correspondence: (K.M.); (N.P.S.)
| | - Nagaraj P. Shetti
- Department of Chemistry, School of Advanced Sciences, KLE Technological University, Vidyanagar, Hubballi 580 031, Karnataka, India; (Y.M.S.); (S.J.M.); (S.D.)
- Correspondence: (K.M.); (N.P.S.)
| |
Collapse
|
19
|
Norizan MN, Abdullah N, Halim NA, Demon SZN, Mohamad IS. Heterojunctions of rGO/Metal Oxide Nanocomposites as Promising Gas-Sensing Materials-A Review. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:2278. [PMID: 35808113 PMCID: PMC9268638 DOI: 10.3390/nano12132278] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 06/21/2022] [Accepted: 06/25/2022] [Indexed: 01/25/2023]
Abstract
Monitoring environmental hazards and pollution control is vital for the detection of harmful toxic gases from industrial activities and natural processes in the environment, such as nitrogen dioxide (NO2), ammonia (NH3), hydrogen (H2), hydrogen sulfide (H2S), carbon dioxide (CO2), and sulfur dioxide (SO2). This is to ensure the preservation of public health and promote workplace safety. Graphene and its derivatives, especially reduced graphene oxide (rGO), have been designated as ideal materials in gas-sensing devices as their electronic properties highly influence the potential to adsorb specified toxic gas molecules. Despite its exceptional sensitivity at low gas concentrations, the sensor selectivity of pristine graphene is relatively weak, which limits its utility in many practical gas sensor applications. In view of this, the hybridization technique through heterojunction configurations of rGO with metal oxides has been explored, which showed promising improvement and a synergistic effect on the gas-sensing capacity, particularly at room temperature sensitivity and selectivity, even at low concentrations of the target gas. The unique features of graphene as a preferential gas sensor material are first highlighted, followed by a brief discussion on the basic working mechanism, fabrication, and performance of hybridized rGO/metal oxide-based gas sensors for various toxic gases, including NO2, NH3, H2, H2S, CO2, and SO2. The challenges and prospects of the graphene/metal oxide-based based gas sensors are presented at the end of the review.
Collapse
Affiliation(s)
- Mohd Nurazzi Norizan
- Centre for Defence Foundation Studies, National Defence University of Malaysia, Kem Sungai Besi, Kuala Lumpur 57000, Malaysia; (M.N.N.); (N.A.H.); (S.Z.N.D.)
| | - Norli Abdullah
- Centre for Defence Foundation Studies, National Defence University of Malaysia, Kem Sungai Besi, Kuala Lumpur 57000, Malaysia; (M.N.N.); (N.A.H.); (S.Z.N.D.)
| | - Norhana Abdul Halim
- Centre for Defence Foundation Studies, National Defence University of Malaysia, Kem Sungai Besi, Kuala Lumpur 57000, Malaysia; (M.N.N.); (N.A.H.); (S.Z.N.D.)
| | - Siti Zulaikha Ngah Demon
- Centre for Defence Foundation Studies, National Defence University of Malaysia, Kem Sungai Besi, Kuala Lumpur 57000, Malaysia; (M.N.N.); (N.A.H.); (S.Z.N.D.)
| | - Imran Syakir Mohamad
- Faculty of Mechanical Engineering, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, Durian Tunggal, Melaka 76100, Malaysia;
| |
Collapse
|
20
|
Manasa G, Mascarenhas RJ, Shetti NP, Malode SJ, Aminabhavi TM. Biomarkers for Early Diagnosis of Ovarian Carcinoma. ACS Biomater Sci Eng 2022; 8:2726-2746. [PMID: 35762531 DOI: 10.1021/acsbiomaterials.2c00390] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The leading cause of gynecological cancer-related morbidity and mortality is ovarian cancer (OC), which is dubbed a silent killer. Currently, OC is a target of intense biomarker research, because it is often not discovered until the disease is advanced. The goal of OC research is to develop effective tests using biomarkers that can detect the disease at the earliest stages, which would eventually decrease the mortality, thereby preventing recurrence. Therefore, there is a pressing need to revisit the existing biomarkers to recognize the potential biomarkers that can lead to efficient predictors for the OC diagnosis. This Perspective covers an update on the currently available biomarkers used in the triaging of OC to gain certain insights into the potential role of these biomarkers and their estimation that are crucial to the understanding of neoplasm progression, diagnostics, and therapy.
Collapse
Affiliation(s)
- G Manasa
- Electrochemistry Research Group, St. Joseph's College, Lalbagh Road, Bangalore - 560027, Karnataka, India
| | - Ronald J Mascarenhas
- Electrochemistry Research Group, St. Joseph's College, Lalbagh Road, Bangalore - 560027, Karnataka, India
| | - Nagaraj P Shetti
- Department of Chemistry, School of Advanced Sciences, KLE Technological University, Vidhyanagar, Hubballi - 580031, Karnataka, India
| | - Shweta J Malode
- Department of Chemistry, School of Advanced Sciences, KLE Technological University, Vidhyanagar, Hubballi - 580031, Karnataka, India
| | - Tejraj M Aminabhavi
- Department of Chemistry, School of Advanced Sciences, KLE Technological University, Vidhyanagar, Hubballi - 580031, Karnataka, India
| |
Collapse
|
21
|
Fu L, Mao S, Chen F, Zhao S, Su W, Lai G, Yu A, Lin CT. Graphene-based electrochemical sensors for antibiotic detection in water, food and soil: A scientometric analysis in CiteSpace (2011-2021). CHEMOSPHERE 2022; 297:134127. [PMID: 35240147 DOI: 10.1016/j.chemosphere.2022.134127] [Citation(s) in RCA: 44] [Impact Index Per Article: 14.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2022] [Revised: 02/11/2022] [Accepted: 02/24/2022] [Indexed: 05/25/2023]
Abstract
The residues of antibiotics in the environment pose a potential health hazard, so highly sensitive detection of antibiotics has always appealed to analytical chemists. With the widespread use of new low-dimensional materials, graphene-modified electrochemical sensors have emerged as an excellent candidate for highly sensitive detection of antibiotics. Graphene, its derivatives and its composites have been used in this field of exploration in the last decade. In this review, we have not only described the field using traditional summaries, but also used bibliometrics to quantify the development of the field. The literature between 2011 and 2021 was included in the analysis. Also, the sensing performance and detection targets of different sensors were compared. We were able to trace not only the flow of research themes, but also the future areas of development. Graphene is a material that has a high potential to be used on a large scale in the preparation of electrochemical sensors. How to design a sensor with selectivity and low cost is the key to bring this material from the laboratory to practical applications.
Collapse
Affiliation(s)
- Li Fu
- Key Laboratory of Novel Materials for Sensor of Zhejiang Province, College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018, China.
| | - Shuduan Mao
- Key Laboratory of Pollution Exposure and Health Intervention of Zhejiang Province, Interdisciplinary Research Academy, Zhejiang Shuren University, Hangzhou 310021, China.
| | - Fei Chen
- Key Laboratory of Novel Materials for Sensor of Zhejiang Province, College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018, China
| | - Shichao Zhao
- Key Laboratory of Novel Materials for Sensor of Zhejiang Province, College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018, China
| | - Weitao Su
- School of Sciences, Hangzhou Dianzi University, Hangzhou, 310018, China
| | - Guosong Lai
- Hubei Key Laboratory of Pollutant Analysis & Reuse Technology, College of Chemistry and Chemical Engineering, Hubei Normal University, Huangshi 435002, China
| | - Aimin Yu
- Department of Chemistry and Biotechnology, Faculty of Science, Engineering and Technology, Swinburne University of Technology, Hawthorn, VIC, 3122, Australia
| | - Cheng-Te Lin
- Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China
| |
Collapse
|
22
|
Karimi-Maleh H, Beitollahi H, Senthil Kumar P, Tajik S, Jahani PM, Karimi F, Karaman C, Vasseghian Y, Baghayeri M, Rouhi J, Show PL, Rajendran S, Fu L, Zare N. Recent advances in carbon nanomaterials-based electrochemical sensors for food azo dyes detection. Food Chem Toxicol 2022; 164:112961. [PMID: 35395340 DOI: 10.1016/j.fct.2022.112961] [Citation(s) in RCA: 163] [Impact Index Per Article: 54.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Revised: 03/17/2022] [Accepted: 03/22/2022] [Indexed: 01/24/2023]
Abstract
Azo dyes as widely applied food colorants are popular for their stability and affordability. On the other hand, many of these dyes can have harmful impacts on living organs, which underscores the need to control the content of this group of dyes in food. Among the various analytical approaches for detecting the azo dyes, special attention has been paid to electro-analytical techniques for reasons such as admirable sensitivity, excellent selectivity, reproducibility, miniaturization, green nature, low cost, less time to prepare and detect of specimens and the ability to modify the electrode. Satisfactory results have been obtained so far for carbon-based nanomaterials in the fabrication of electrochemical sensing systems in detecting the levels of these materials in various specimens. The purpose of this review article is to investigate carbon nanomaterial-supported techniques for electrochemical sensing systems on the analysis of azo dyes in food samples in terms of carbon nanomaterials used, like carbon nanotubes (CNT) and grapheme (Gr).
Collapse
Affiliation(s)
- Hassan Karimi-Maleh
- School of Resources and Environment, University of Electronic Science and Technology of China, P.O. Box 611731, Xiyuan Ave, Chengdu, PR China; Department of Chemical Engineering, Quchan University of Technology, Quchan, 9477177870, Iran.
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran.
| | - P Senthil Kumar
- Department of Chemical Engineering, Sri Sivasubramaniya Nadar College of Engineering, Kalavakkam, Chennai, 603110, India.
| | - Somayeh Tajik
- Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman, Iran
| | | | - Fatemeh Karimi
- Department of Chemical Engineering, Quchan University of Technology, Quchan, 9477177870, Iran.
| | - Ceren Karaman
- Department of Electricity and Energy, Akdeniz University, Antalya, 07070, Turkey
| | - Yasser Vasseghian
- Department of Chemistry, Soongsil University, Seoul, 06978, South Korea
| | - Mehdi Baghayeri
- Department of Chemistry, Faculty of Science, Hakim Sabzevari University, P.O. Box 397, Sabzevar, Iran
| | - Jalal Rouhi
- Faculty of Physics, University of Tabriz, Tabriz, 51566, Iran
| | - Pau-Loke Show
- Department of Chemical and Environmental Engineering, Faculty of Science and Engineering, University of Nottingham Malaysia, Jalan Broga, Semenyih, 43500, Selangor Darul Ehsan, Malaysia
| | - Saravanan Rajendran
- Faculty of Engineering, Department of Mechanical Engineering, University of Tarapaca, 1775, Arica, Chile
| | - Li Fu
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou, 310018, PR China
| | - Najmeh Zare
- Department of Chemical Engineering, Quchan University of Technology, Quchan, 9477177870, Iran
| |
Collapse
|
23
|
He S, Zhang Y, Gao J, Nag A, Rahaman A. Integration of Different Graphene Nanostructures with PDMS to Form Wearable Sensors. NANOMATERIALS (BASEL, SWITZERLAND) 2022; 12:950. [PMID: 35335764 PMCID: PMC8949288 DOI: 10.3390/nano12060950] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/19/2022] [Revised: 03/09/2022] [Accepted: 03/11/2022] [Indexed: 02/07/2023]
Abstract
This paper presents a substantial review of the fabrication and implementation of graphene-PDMS-based composites for wearable sensing applications. Graphene is a pivotal nanomaterial which is increasingly being used to develop multifunctional sensors due to their enhanced electrical, mechanical, and thermal characteristics. It has been able to generate devices with excellent performances in terms of sensitivity and longevity. Among the polymers, polydimethylsiloxane (PDMS) has been one of the most common ones that has been used in biomedical applications. Certain attributes, such as biocompatibility and the hydrophobic nature of PDMS, have led the researchers to conjugate it in graphene sensors as substrates or a polymer matrix. The use of these graphene/PDMS-based sensors for wearable sensing applications has been highlighted here. Different kinds of electrochemical and strain-sensing applications have been carried out to detect the physiological signals and parameters of the human body. These prototypes have been classified based on the physical nature of graphene used to formulate the sensors. Finally, the current challenges and future perspectives of these graphene/PDMS-based wearable sensors are explained in the final part of the paper.
Collapse
Affiliation(s)
- Shan He
- School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (S.H.); (Y.Z.)
- Institute for NanoScale Science and Technology, College of Science and Engineering, Flinders University, Bedford Park 5042, Australia
| | - Yang Zhang
- School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (S.H.); (Y.Z.)
| | - Jingrong Gao
- School of Chemistry and Chemical Engineering, Guangzhou University, Guangzhou 510006, China; (S.H.); (Y.Z.)
- School of Food Science and Engineering, South China University of Technology, Guangzhou 510640, China
| | - Anindya Nag
- Faculty of Electrical and Computer Engineering, Technische Universität Dresden, 01062 Dresden, Germany
- Centre for Tactile Internet with Human-in-the-Loop (CeTI), Technische Universität Dresden, 01069 Dresden, Germany
| | - Abdul Rahaman
- School of Food Science and Engineering, South China University of Technology, Guangzhou 510640, China
| |
Collapse
|
24
|
Manimekala T, Sivasubramanian R, Dharmalingam G. Nanomaterial-Based Biosensors using Field-Effect Transistors: A Review. JOURNAL OF ELECTRONIC MATERIALS 2022; 51:1950-1973. [PMID: 35250154 PMCID: PMC8881998 DOI: 10.1007/s11664-022-09492-z] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Accepted: 02/01/2022] [Indexed: 05/05/2023]
Abstract
Field-effect transistor biosensors (Bio-FET) have attracted great interest in recent years owing to their distinctive properties like high sensitivity, good selectivity, and easy integration into portable and wearable electronic devices. Bio-FET performance mainly relies on the constituent components such as the bio-recognition layer and the transducer, which ensures device stability, sensitivity, and lifetime. Nanomaterial-based Bio-FETs are excellent candidates for biosensing applications. This review discusses the basic concepts, function, and working principles of Bio-FETs, and focuses on the progress of recent research in Bio-FETs in the sensing of neurotransmitters, glucose, nucleic acids, proteins, viruses, and cancer biomarkers using nanomaterials. Finally, challenges in the development of Bio-FETs, as well as an outlook on the prospects of nano Bio-FET-based sensing in various fields, are discussed.
Collapse
Affiliation(s)
- T. Manimekala
- Plasmonic Nanomaterials Laboratory, PSG Institute of Advanced Studies, Peelamedu, Coimbatore, Tamilnadu 641004 India
- Electrochemical Sensors and Energy Materials Laboratory, PSG Institute of Advanced Studies, Peelamedu, Coimbatore, Tamilnadu 641004 India
| | - R. Sivasubramanian
- Electrochemical Sensors and Energy Materials Laboratory, PSG Institute of Advanced Studies, Peelamedu, Coimbatore, Tamilnadu 641004 India
| | - Gnanaprakash Dharmalingam
- Plasmonic Nanomaterials Laboratory, PSG Institute of Advanced Studies, Peelamedu, Coimbatore, Tamilnadu 641004 India
| |
Collapse
|
25
|
The Construct CoSe 2 on Carbon Nanosheets as High Sensitivity Catalysts for Electro-Catalytic Oxidation of Glucose. NANOMATERIALS 2022; 12:nano12030572. [PMID: 35159917 PMCID: PMC8838914 DOI: 10.3390/nano12030572] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Revised: 02/05/2022] [Accepted: 02/05/2022] [Indexed: 12/01/2022]
Abstract
Seeking an efficient, sensitive, and stable catalyst is crucial for no-enzyme glucose sen-sors to detect glucose content accurately. Herein, we constructed a catalyst of selenide cobalt (CoSe2) on carbon nanomaterials by auxiliary pyrolysis of sodium chloride. The CoSe2 on carbon nanosheets possesses good selectivity and a wide linear range up to 5 mM. Based on its good detection per-formance, the CoSe2 nanomaterial is expected to be an emerging catalyst for no-enzyme sensors.
Collapse
|
26
|
Malathi S, Pakrudheen I, Kalkura SN, Webster T, Balasubramanian S. Disposable biosensors based on metal nanoparticles. SENSORS INTERNATIONAL 2022; 3:100169. [PMID: 35252890 PMCID: PMC8889882 DOI: 10.1016/j.sintl.2022.100169] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 02/28/2022] [Accepted: 03/01/2022] [Indexed: 02/06/2023] Open
Abstract
The coronavirus disease2019 (COVID-19) pandemic has highlighted the need for disposable biosensors that can detect viruses in infected patients quickly due to fast response and also at a low cost.The present review provides an overview of the applications of disposable biosensors based on metal nanoparticles in enzymatic and non-enzymatic sensors with special reference to glucose and H2O2, immunosensors as well as genosensors (DNA biosensors in which the recognized event consists of the hybridization reaction)for point-of-care diagnostics. The disposable biosensors for COVID19 have also been discussed.
Collapse
Affiliation(s)
- S. Malathi
- Crystal Growth Centre, Anna University, Guindy, Chennai, 600025, India
| | - I. Pakrudheen
- Department of Chemistry, CMR Institute of Technology, Bengaluru, 560037, Karnataka, India
| | | | - T.J. Webster
- Department of Chemical Engineering, Northeastern University, Boston, MA, 02115, USA
| | - S. Balasubramanian
- Department of Inorganic Chemistry, University of Madras, Guindy, Chennai, 600025, India,Corresponding author
| |
Collapse
|
27
|
Alizadeh M, Nodehi M, Salmanpour S, Karimi F, Sanati AL, Malekmohammadi S, Zakariae N, Esmaeili R, Jafari H. Properties and Recent Advantages of N,N’-dialkylimidazolium-ion Liquids
Application in Electrochemistry. CURR ANAL CHEM 2022. [DOI: 10.2174/1573411016999201022141930] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
:
N,Nʹ-dialkylimidazolium-ion liquids is one of the important ionic liquids with a wide range of application as
conductive electrolyte and in electrochemistry. The modified electrodes create a new view in fabrication of
electroanalytical sensors. Many modifiers have beeen suggested for modification of electroanalytical sensor since many
years ago. Over these years, ionic liquids and especially room temperature ionic liquids have attracted more attention due
to their wide range of electrochemical windows and high electrical conductivity. N,Nʹ-dialkylimidazolium-ion liquids are
one of the main important ionic liquids suggested for modification of bare electrodes and especially carbon paste
electrodes. Although many review articles have reported onthe use of ionic liquids in electrochemical sensors, no review
article has been specifically introduced so far on the review of the advantages of N,Nʹ-dialkylimidazolium ionic liquid.
Therefore, in this review paper we focused on the introduction of recent advantages of N,Nʹ-dialkyl imidazolium ionic
liquid in electrochemistry.
Collapse
Affiliation(s)
- Marzieh Alizadeh
- Laboratory of Basic Sciences, Mohammad Rasul Allah Research Tower, Shiraz University of Medical Sciences, Shiraz,
PO Box: 71348-14336, Iran
| | - Marzieh Nodehi
- Department of Chemistry, Faculty of Science, Hakim Sabzevari University, PO. Box 397, Sabzevar,Iran
| | - Sadegh Salmanpour
- Department of Chemistry, Sari Branch, Islamic Azad University, Sari,Iran
| | - Fatemeh Karimi
- Nanostructure Based Biosensors Research Group, Ton Duc Thang University, Ho Chi Minh City,Vietnam
| | - Afsaneh L. Sanati
- Department of Chemical Engineering, Laboratory of Nanotechnology, Quchan University of Technology, Quchan,Iran
| | - Samira Malekmohammadi
- Department of Chemical Engineering, Laboratory of Nanotechnology, Quchan University of Technology, Quchan,Iran
| | - Nilofar Zakariae
- Nursing Medical-Surgical Group, Shahid Beheshti University of Medical Science, Tehran,Iran
| | - Roghayeh Esmaeili
- Nursing Medical-Surgical Group, Shahid Beheshti University of Medical Science, Tehran,Iran
| | - Hedayat Jafari
- Traditional and Complementary Medicine Research Center, Addiction Institute, Mazandaran University of Medical Sciences, Sari,Iran
| |
Collapse
|
28
|
Miao Y, Wang X, Liu Y, Liu Z, Chen W. Preparation of Graphene Oxide/Cellulose Composites with Microcrystalline Cellulose Acid Hydrolysis Using the Waste Acids Generated by the Hummers Method of Graphene Oxide Synthesis. Polymers (Basel) 2021; 13:polym13244453. [PMID: 34961004 PMCID: PMC8706496 DOI: 10.3390/polym13244453] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 11/30/2021] [Accepted: 12/15/2021] [Indexed: 11/27/2022] Open
Abstract
The Hummers method is the most commonly used method to prepare graphene oxide (GO). However, many waste acids remain in the raw reaction mixture after the completion of this reaction. The aim of this study was to reuse these waste acids efficiently. In this study, microcrystalline cellulose (MCC) was directly dissolved in the mixture after the high-temperature reaction of the Hummers method. The residual acid was used to hydrolyze MCC, and the graphene oxide/microcrystalline cellulose (GO/MCC) composites were prepared, while the acid was reused. The effects of MCC addition (0.5 g, 1.0 g, and 1.5 g in 20 mL) on the properties of the composites were discussed. The structure, composition, thermal stability, and hydrophobicity of GO/MCC composites were characterized and tested by SEM, XRD, FTIR, TG, and contact angle tests. The results showed that MCC could be acid hydrolyzed into micron and nano-scale cellulose by using the strong acidity of waste liquid after GO preparation, and it interacted with the prepared GO to form GO/MCC composites. When the addition amount of MCC was 1 g, the thermal stability of the composite was the highest due to the interaction between acid-hydrolyzed MCC and GO sheets. At the same time, the hydrophobic property of the GO/MCC composite is better than that of the GO film. The freeze-dried GO/MCC composites are more easily dispersed in water and have stronger stability.
Collapse
Affiliation(s)
| | | | | | - Zhenbo Liu
- Correspondence: (Z.L.); (W.C.); Tel.: +86-13-(94)-5697965 (Z.L.)
| | - Wenshuai Chen
- Correspondence: (Z.L.); (W.C.); Tel.: +86-13-(94)-5697965 (Z.L.)
| |
Collapse
|
29
|
Sharafeldin M, James T, Davis JJ. Open Circuit Potential as a Tool for the Assessment of Binding Kinetics and Reagentless Protein Quantitation. Anal Chem 2021; 93:14748-14754. [PMID: 34699180 DOI: 10.1021/acs.analchem.1c03292] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
A microfluidic open circuit potential label-free protein assay was developed for the reagentless quantification of C-reactive protein (CRP), a model protein target, and further utilized to assess target-receptor binding kinetics. Generated sensors have very high baseline stabilities (<1% change in 100 min) and high levels of selectivity in complex media. Real-time assays are fast (<20 min), of high sensitivity (1 ng/mL limit of detection for CRP in serum), and resolve kinetic and thermodynamic characteristics that correlate well with those resolved optically. The assay shows excellent correlation with an enzyme-linked immunosorbent assay analysis of patient samples. The methodology has value in potentially underpinning a low-cost, rapid, and sensitive single-step biomarker quantification.
Collapse
Affiliation(s)
- Mohamed Sharafeldin
- Department of Chemistry, University of Oxford, South Parks Road, Oxford OX1 3QZ, U.K
| | - Timothy James
- Department of Clinical Biochemistry, Oxford University Hospitals NHS Trust, Oxford OX3 9DU, U.K
| | - Jason J Davis
- Department of Chemistry, University of Oxford, South Parks Road, Oxford OX1 3QZ, U.K
| |
Collapse
|
30
|
Bukkitgar SD, Shetti NP, Aminabhavi TM. Electrochemical investigations for COVID-19 detection-A comparison with other viral detection methods. CHEMICAL ENGINEERING JOURNAL (LAUSANNE, SWITZERLAND : 1996) 2021; 420:127575. [PMID: 33162783 PMCID: PMC7605744 DOI: 10.1016/j.cej.2020.127575] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2020] [Revised: 10/07/2020] [Accepted: 10/26/2020] [Indexed: 05/02/2023]
Abstract
Virus-induced infection such as SARS-CoV-2 is a serious threat to human health and the economic setback of the world. Continued advances in the development of technologies are required before the viruses undergo mutation. The low concentration of viruses in environmental samples makes the detection extremely challenging; simple, accurate and rapid detection methods are in urgent need. Of all the analytical techniques, electrochemical methods have the established capabilities to address the issues. Particularly, the integration of nanotechnology would allow miniature devices to be made available at the point-of-care. This review outlines the capabilities of electrochemical methods in conjunction with nanotechnology for the detection of SARS-CoV-2. Future directions and challenges of the electrochemical biosensors for pathogen detection are covered including wearable and conformal biosensors, detection of plant pathogens, multiplexed detection, and reusable biosensors for on-site monitoring, thereby providing low-cost and disposable biosensors.
Collapse
Key Words
- AIV H5N1, Avian influenza
- AIV, Avian influenza virus
- ASFV, African swine fever virus
- BVDV, Bovine viral diarrhea virus
- CGV, Chikungunya viruses
- CMV, Cucumber mosaic virus
- COVID-19
- CSFV, Classic swine fever virus
- CV, Cyclic voltammetry
- DAstV-1, Duck astrovirus 1
- DAstV-2, Duck astrovirus 2
- DENV, Dengue virus
- DEV, Duck enteritis virus
- DHAV-1, Duck hepatitis A virus 1
- DHAV-3, Duck hepatitis A virus 3
- DPV, Differential pulse voltammetry
- DRV-1, Duck reovirus 1
- DRV-2, Duck reovirus 2
- Detection
- EBV, Epstein-Barr virus
- EIS, Electric impedance spectroscopy
- EPC, External positive controls
- EV, Human enterovirus
- EV71, Human enterovirus 71
- Electrochemical sensor
- FMI SMOF, Fluorescence molecularly imprinted sensor based on a metal–organic framework
- GCE, Glassy carbon electrode
- GCFaV-1, Ginger chlorotic fleck associated virus 1
- GCFaV-2, Ginger chlorotic fleck-associated virus 2
- GEV VN-96, Gastroenteritis virus VN-96
- GPV, Goose parvovirus
- HHV, Human herpes virus 6
- HIAV, Human influenza A viruses
- HPB19, Human parvovirus B19
- HSV, Herpes simplex
- IAV, influenza A virus
- IEA, Interdigitated electrode array
- IMA, Interdigitated microelectrode array
- INAA, Isothermal nucleic acid amplification-based
- JEV, Japanese encephalitis virus
- LAMP, Loop-Mediated Isothermal Amplification
- LSV, Linear sweep voltammetry
- MERS, Middle East respiratory syndrome
- MIEC, Molecularly imprinted electrochemiluminescence
- MNV, Murine norovirus
- MeV, Measles virus
- NNV, Nervous necrosis virus
- Nanotechnology
- PBoV, Porcine bocavirus
- PCNAME, Pt-coated nanostructured alumina membrane electrode
- PCR
- PCRLFS, Polymerase Chain Reaction with a lateral flow strip with a lateral flow strip
- PCV, Porcine circovirus 3
- PEDV, Porcine epidemic diarrhoea virus
- PRRSV, porcine reproductive and respiratory syndrome virus
- PSV, Pseudorabies virus
- RCA, Rolling circle amplification
- RGO, Reduced graphene oxide
- RT-LAMP-VF, RT-LAMP and a vertical flow visualization strip
- RV, Rubella virus
- SARS, Severe acute respiratory syndrome
- SIVH1N1, Swine influenza virus
- SWV, Square wave voltammetry
- TGEV, transmissible gastroenteritis coronavirus
- TMUV, Tembusu virus
- USEGFET, Ultra-sensitive electrolyte-gated field-effect transistor
- VZV, Varicella-zoster virus
- VZV, varicella-Zoster virus
- Viruses
- ZV, Zika virus
Collapse
Affiliation(s)
- Shikandar D Bukkitgar
- Centre for Electrochemical Science and Materials, Department of Chemistry, K.L.E. Institute of Technology, Gokul, Hubballi 580030, Karnataka, India
| | - Nagaraj P Shetti
- Centre for Electrochemical Science and Materials, Department of Chemistry, K.L.E. Institute of Technology, Gokul, Hubballi 580030, Karnataka, India
| | - Tejraj M Aminabhavi
- Pharmaceutical Engineering, Soniya College of Pharmacy, Dharwad 580-007, India
| |
Collapse
|
31
|
Cerium oxide nanofiber–based electrochemical immunosensor for detection of sepsis in biological fluid. J Solid State Electrochem 2021. [DOI: 10.1007/s10008-021-05042-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
32
|
Abstract
This paper presents an accurate and fast electrochemical method for atorvastatin determination in pharmaceutical products. Two screen-printed sensors, one—carbon based (SPCE) and one based on carbon nanotubes and gold nanoparticles (AuNP-CNT/SPCE) were used during the electrochemical analyses. At all experimental stages, cyclic voltammetry was employed, both for the characterization of the sensors and their electrochemical behavior, and for quantitative determinations. AuNP-CNT/SPCE has showed an extended active area, higher intensity peaks, better reversibility and lower background current than the unmodified sensor. For atorvastatin quantification, a calibration curve has been developed within the 1.2–606.25 µM concentration range. A linearity relation between the current of the anodic peak and concentration has been obtained in the range 1.2–53.33 µMfor both sensors. With the AuNP-CNT/SPCE sensor, low values of limit of detection, LOD (1.92 × 10−7 M) and limit of quantification, LOQ (6.39 × 10−7 M) have been obtained, which demonstrates the feasibility of the method of determining atorvastatin from real samples. Atorvastatin amount has been successfully determined from pharmaceutical products using AuNP-CNT/SPCE. The results were similar to the manufacturer’s specifications regarding the dosage per tablet and to the concentrations obtained by applying the FTIR spectrometric method.
Collapse
|
33
|
Efficient Electrochemical Determination of Catechol with Hydroquinone at Poly (L‐Serine) Layered Carbon Paste Electrode. ChemistrySelect 2021. [DOI: 10.1002/slct.202101809] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
34
|
Banitaba SN, Ehrmann A. Application of Electrospun Nanofibers for Fabrication of Versatile and Highly Efficient Electrochemical Devices: A Review. Polymers (Basel) 2021; 13:1741. [PMID: 34073391 PMCID: PMC8197972 DOI: 10.3390/polym13111741] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Revised: 05/23/2021] [Accepted: 05/24/2021] [Indexed: 02/06/2023] Open
Abstract
Electrochemical devices convert chemical reactions into electrical energy or, vice versa, electricity into a chemical reaction. While batteries, fuel cells, supercapacitors, solar cells, and sensors belong to the galvanic cells based on the first reaction, electrolytic cells are based on the reversed process and used to decompose chemical compounds by electrolysis. Especially fuel cells, using an electrochemical reaction of hydrogen with an oxidizing agent to produce electricity, and electrolytic cells, e.g., used to split water into hydrogen and oxygen, are of high interest in the ongoing search for production and storage of renewable energies. This review sheds light on recent developments in the area of electrospun electrochemical devices, new materials, techniques, and applications. Starting with a brief introduction into electrospinning, recent research dealing with electrolytic cells, batteries, fuel cells, supercapacitors, electrochemical solar cells, and electrochemical sensors is presented. The paper concentrates on the advantages of electrospun nanofiber mats for these applications which are mostly based on their high specific surface area and the possibility to tailor morphology and material properties during the spinning and post-treatment processes. It is shown that several research areas dealing with electrospun parts of electrochemical devices have already reached a broad state-of-the-art, while other research areas have large space for future investigations.
Collapse
Affiliation(s)
| | - Andrea Ehrmann
- Faculty of Engineering and Mathematics, Bielefeld University of Applied Sciences, 33619 Bielefeld, Germany
| |
Collapse
|
35
|
A New Method for Dispersing Pristine Carbon Nanotubes Using Regularly Arranged S-Layer Proteins. NANOMATERIALS 2021; 11:nano11051346. [PMID: 34065322 PMCID: PMC8161383 DOI: 10.3390/nano11051346] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Revised: 05/14/2021] [Accepted: 05/18/2021] [Indexed: 01/25/2023]
Abstract
Homogeneous and stable dispersions of functionalized carbon nanotubes (CNTs) in aqueous solutions are imperative for a wide range of applications, especially in life and medical sciences. Various covalent and non-covalent approaches were published to separate the bundles into individual tubes. In this context, this work demonstrates the non-covalent modification and dispersion of pristine multi-walled carbon nanotubes (MWNTs) using two S-layer proteins, namely, SbpA from Lysinibacillus sphaericus CCM2177 and SbsB from Geobacillus stearothermophilus PV72/p2. Both the S-layer proteins coated the MWNTs completely. Furthermore, it was shown that SbpA can form caps at the ends of MWNTs. Reassembly experiments involving a mixture of both S-layer proteins in the same solution showed that the MWNTs were primarily coated with SbsB, whereas SbpA formed self-assembled layers. The dispersibility of the pristine nanotubes coated with SbpA was determined by zeta potential measurements (−24.4 +/− 0.6 mV, pH = 7). Finally, the SbpA-coated MWNTs were silicified with tetramethoxysilane (TMOS) using a mild biogenic approach. As expected, the thickness of the silica layer could be controlled by the reaction time and was 6.3 +/− 1.25 nm after 5 min and 25.0 +/− 5.9 nm after 15 min. Since S-layer proteins have already demonstrated their capability to bind (bio)molecules in dense packing or to act as catalytic sites in biomineralization processes, the successful coating of pristine MWNTs has great potential in the development of new materials, such as biosensor architectures.
Collapse
|
36
|
Wu Z, Liu J, Liang M, Zheng H, Zhu C, Wang Y. Detection of Imatinib Based on Electrochemical Sensor Constructed Using Biosynthesized Graphene-Silver Nanocomposite. Front Chem 2021; 9:670074. [PMID: 33968906 PMCID: PMC8100453 DOI: 10.3389/fchem.2021.670074] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2021] [Accepted: 03/19/2021] [Indexed: 11/13/2022] Open
Abstract
The establishment of a monitoring technique for imatinib is necessary in clinical and environmental toxicology. Leaf extracts of Lycoris longituba were used as reducing agent for the one-step synthesis of reduced graphene oxide-Ag nanocomposites. This nanocomposite was characterized by TEM, FTIR, XRD, and other instruments. Then, the graphene/Ag nanocomposite was used as a modifier to be cemented on the surface of the glassy carbon electrode. This electrode exhibited excellent electrochemical sensing performance. Under the optimal conditions, the proposed electrode could detect imatinib at 10 nM−0.28 mM with a low limit of detection. This electrochemical sensor also has excellent anti-interference performance and reproducibility.
Collapse
Affiliation(s)
- Zhen Wu
- Day Chemotherapy Unit, Qianfoshan Hospital, The First Affiliated Hospital of Shandong First Medical University, Jinan, China
| | - Jingjing Liu
- Hematology Department, Qianfoshan Hospital, The First Affiliated Hospital of Shandong First Medical University, Jinan, China
| | | | | | - Chuansheng Zhu
- Hematology Department, Qianfoshan Hospital, The First Affiliated Hospital of Shandong First Medical University, Jinan, China
| | - Yan Wang
- Hematology Department, Qianfoshan Hospital, The First Affiliated Hospital of Shandong First Medical University, Jinan, China
| |
Collapse
|
37
|
Aykaç A, Gergeroglu H, Beşli B, Akkaş EÖ, Yavaş A, Güler S, Güneş F, Erol M. An Overview on Recent Progress of Metal Oxide/Graphene/CNTs-Based Nanobiosensors. NANOSCALE RESEARCH LETTERS 2021; 16:65. [PMID: 33877478 PMCID: PMC8056378 DOI: 10.1186/s11671-021-03519-w] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/20/2021] [Accepted: 03/30/2021] [Indexed: 05/07/2023]
Abstract
Nanobiosensors are convenient, practical, and sensitive analyzers that detect chemical and biological agents and convert the results into meaningful data between a biologically active molecule and a recognition element immobilized on the surface of the signal transducer by a physicochemical detector. Due to their fast, accurate and reliable operating characteristics, nanobiosensors are widely used in clinical and nonclinical applications, bedside testing, medical textile industry, environmental monitoring, food safety, etc. They play an important role in such critical applications. Therefore, the design of the biosensing interface is essential in determining the performance of the nanobiosensor. The unique chemical and physical properties of nanomaterials have paved the way for new and improved sensing devices in biosensors. The growing demand for devices with improved sensing and selectivity capability, short response time, lower limit of detection, and low cost causes novel investigations on nanobiomaterials to be used as biosensor scaffolds. Among all other nanomaterials, studies on developing nanobiosensors based on metal oxide nanostructures, graphene and its derivatives, carbon nanotubes, and the widespread use of these nanomaterials as a hybrid structure have recently attracted attention. Nanohybrid structures created by combining these nanostructures will directly meet the future biosensors' needs with their high electrocatalytic activities. This review addressed the recent developments on these nanomaterials and their derivatives, and their use as biosensor scaffolds. We reviewed these popular nanomaterials by evaluating them with comparative studies, tables, and charts.
Collapse
Affiliation(s)
- Ahmet Aykaç
- Department of Engineering Sciences, Izmir Katip Çelebi University, 35620, Izmir, Turkey.
- Department of Nanoscience and Nanotechnology, Izmir Katip Çelebi University, 35620, Izmir, Turkey.
| | - Hazal Gergeroglu
- Department of Nanoscience and Nanoengineering, Dokuz Eylul University, 35390, Izmir, Turkey
| | - Büşra Beşli
- Department of Nanoscience and Nanotechnology, Izmir Katip Çelebi University, 35620, Izmir, Turkey
| | - Emine Özge Akkaş
- Department of Nanoscience and Nanotechnology, Izmir Katip Çelebi University, 35620, Izmir, Turkey
| | - Ahmet Yavaş
- Department of Material Science and Engineering, Izmir Katip Çelebi University, 35620, Izmir, Turkey
| | - Saadet Güler
- Department of Material Science and Engineering, Izmir Katip Çelebi University, 35620, Izmir, Turkey
| | - Fethullah Güneş
- Department of Material Science and Engineering, Izmir Katip Çelebi University, 35620, Izmir, Turkey
| | - Mustafa Erol
- Department of Metallurgical and Materials Engineering, Dokuz Eylul University, 35390, Izmir, Turkey
| |
Collapse
|
38
|
Menaa F, Fatemeh Y, Vashist SK, Iqbal H, Sharts ON, Menaa B. Graphene, an Interesting Nanocarbon Allotrope for Biosensing Applications: Advances, Insights, and Prospects. Biomed Eng Comput Biol 2021; 12:1179597220983821. [PMID: 33716517 PMCID: PMC7917420 DOI: 10.1177/1179597220983821] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Accepted: 12/07/2020] [Indexed: 12/27/2022] Open
Abstract
Graphene, a relatively new two-dimensional (2D) nanomaterial, possesses unique structure (e.g. lighter, harder, and more flexible than steel) and tunable physicochemical (e.g. electronical, optical) properties with potentially wide eco-friendly and cost-effective usage in biosensing. Furthermore, graphene-related nanomaterials (e.g. graphene oxide, doped graphene, carbon nanotubes) have inculcated tremendous interest among scientists and industrials for the development of innovative biosensing platforms, such as arrays, sequencers and other nanooptical/biophotonic sensing systems (e.g. FET, FRET, CRET, GERS). Indeed, combinatorial functionalization approaches are constantly improving the overall properties of graphene, such as its sensitivity, stability, specificity, selectivity, and response for potential bioanalytical applications. These include real-time multiplex detection, tracking, qualitative, and quantitative characterization of molecules (i.e. analytes [H2O2, urea, nitrite, ATP or NADH]; ions [Hg2+, Pb2+, or Cu2+]; biomolecules (DNA, iRNA, peptides, proteins, vitamins or glucose; disease biomarkers such as genetic alterations in BRCA1, p53) and cells (cancer cells, stem cells, bacteria, or viruses). However, there is still a paucity of comparative reports that critically evaluate the relative toxicity of carbon nanoallotropes in humans. This manuscript comprehensively reviews the biosensing applications of graphene and its derivatives (i.e. GO and rGO). Prospects and challenges are also introduced.
Collapse
Affiliation(s)
- Farid Menaa
- Department of Nanomedicine and Fluoro-Carbon Spectroscopy, Fluorotronics, Inc and California Innovations Corporation, San Diego, CA, USA
| | - Yazdian Fatemeh
- Department of Life Science Engineering, Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran
| | - Sandeep K Vashist
- Hahn-Schickard-Gesellschaft für Angewandte Forschung e.V. (HSG-IMIT), Freiburg, Germany.,College of Pharmaceutical Sciences, Soochow University, Suzhou, P.R. China
| | - Haroon Iqbal
- College of Pharmaceutical Sciences, Soochow University, Suzhou, P.R. China
| | - Olga N Sharts
- Department of Nanomedicine and Fluoro-Carbon Spectroscopy, Fluorotronics, Inc and California Innovations Corporation, San Diego, CA, USA
| | - Bouzid Menaa
- Department of Nanomedicine and Fluoro-Carbon Spectroscopy, Fluorotronics, Inc and California Innovations Corporation, San Diego, CA, USA
| |
Collapse
|
39
|
Graphene for Biosensing Applications in Point-of-Care Testing. Trends Biotechnol 2021; 39:1065-1077. [PMID: 33573848 DOI: 10.1016/j.tibtech.2021.01.005] [Citation(s) in RCA: 40] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Revised: 01/13/2021] [Accepted: 01/14/2021] [Indexed: 02/06/2023]
Abstract
Graphene and graphene-related materials (GRMs) exhibit a unique combination of electronic, optical, and electrochemical properties, which make them ideally suitable for ultrasensitive and selective point-of-care testing (POCT) devices. POCT device-based applications in diagnostics require test results to be readily accessible anywhere to produce results within a short analysis timeframe. This review article provides a summary of methods and latest developments in the field of graphene and GRM-based biosensing in POCT and an overview of the main applications of the latter in nucleic acids and enzymatic biosensing, cell detection, and immunosensing. For each application, we discuss scientific and technological advances along with the remaining challenges, outlining future directions for widespread use of this technology in biomedical applications.
Collapse
|
40
|
Palisoc ST, Vitto RIM, Noel MG, Palisoc KT, Natividad MT. Highly sensitive determination of heavy metals in water prior to and after remediation using Citrofortunella Microcarpa. Sci Rep 2021; 11:1394. [PMID: 33446740 PMCID: PMC7809489 DOI: 10.1038/s41598-020-80672-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2020] [Accepted: 12/24/2020] [Indexed: 11/29/2022] Open
Abstract
A highly sensitive bismuth/silver nanoparticles/Nafion-modified screen-printed graphene electrode was fabricated and was utilized for the detection of trace lead (Pb) concentrations in river water samples prior to and after remediation using calamansi (Citrofortunella Microcarpa) rinds in different forms viz., ground sun-dried, dry-ashed, food-grade pectin, fractionated pectin, and alcohol insoluble solids-extracted pectin. All these forms of pectin remediated Pb in the water samples. Hence, this novel method of using calamansi rinds in different forms is an effective method for the removal of lead in water. The electrode was characterized using scanning electron microscopy and energy dispersive x-ray spectrometry which confirmed the presence of the modifiers on the electrode surface. The limit of detection of 267.6 ppt and the strong linear relationship between the Pb concentration and the anodic current response (R2 = 0.999) were obtained under optimized experimental conditions and parameters.
Collapse
Affiliation(s)
- Shirley T Palisoc
- Condensed Matter Research Unit, CENSER, De La Salle University, 2401 Taft Ave, 922, Manila, Philippines
| | - Remuel Isaac M Vitto
- Physics Department, De La Salle University, 2401 Taft Ave, 922, Manila, Philippines
| | - Marissa G Noel
- Chemistry Department, De La Salle University, 2401 Taft Ave, 922, Manila, Philippines
| | - Katja T Palisoc
- Chemistry Department, De La Salle University, 2401 Taft Ave, 922, Manila, Philippines
| | - Michelle T Natividad
- Condensed Matter Research Unit, CENSER, De La Salle University, 2401 Taft Ave, 922, Manila, Philippines.
- Physics Department, De La Salle University, 2401 Taft Ave, 922, Manila, Philippines.
| |
Collapse
|
41
|
Tian J, Mu Z, Wang J, Zhou J, Yuan Y, Bai L. Electrochemical aptasensor for ultrasensitive detection of lipopolysaccharide using silver nanoparticles decorated titanium dioxide nanotube/functionalized reduced graphene oxide as a new redox nanoprobe. Mikrochim Acta 2021; 188:31. [PMID: 33415459 DOI: 10.1007/s00604-020-04695-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Accepted: 12/27/2020] [Indexed: 01/06/2023]
Abstract
A novel and relatively simple signal-off electrochemical aptasensor was constructed for highly sensitive detection of lipopolysaccharide (LPS). For the first time, silver nanoparticles (AgNPs) decorated titanium dioxide nanotube (TNT) was conjugated with polydiallyldimethylammonium chloride (PDDA) functionalized reduced graphene oxide (rGO) to form a new nanohybrid of Ag-TNT/P-rGO. This nanohybrid with a large specific surface area exhibited excellent electrochemical activity, which not only served as the sensing platform to immobilize LPS binding aptamer (LBA) but was also employed as the redox probe to monitor the change of the electrochemical signal. The electrochemical signal responses were measured by cyclic voltammetry (CV) in the potential range -0.3 to 0.5 V at a scan rate of 0.1 V/s. The proposed aptasensor exhibited acceptable stability, reproducibility, and specificity for LPS detection with a wide linear range from 17 fg/mL to 100 ng/mL. The limit of detection (LOD) was 5 fg/mL. Furthermore, the prepared aptasensor showed acceptable recovery ranging from 96% to 103%, and the RSD varied between 1.4% and 8.5% for determining LPS in real samples.Graphical abstract.
Collapse
Affiliation(s)
- Jiangman Tian
- Chongqing Research Center for Pharmaceutical Engineering, College of Pharmacy, Chongqing Medical University, Chongqing, 400016, People's Republic of China
| | - Zhaode Mu
- Research Center for Pharmacodynamic Evaluation Engineering Technology of Chongqing, College of Pharmacy, Chongqing Medical University, Chongqing, 400016, People's Republic of China
| | - Jie Wang
- Research Center for Pharmacodynamic Evaluation Engineering Technology of Chongqing, College of Pharmacy, Chongqing Medical University, Chongqing, 400016, People's Republic of China
| | - Jing Zhou
- Chongqing Research Center for Pharmaceutical Engineering, College of Pharmacy, Chongqing Medical University, Chongqing, 400016, People's Republic of China
| | - Yonghua Yuan
- Research Center for Pharmacodynamic Evaluation Engineering Technology of Chongqing, College of Pharmacy, Chongqing Medical University, Chongqing, 400016, People's Republic of China
| | - Lijuan Bai
- Chongqing Research Center for Pharmaceutical Engineering, College of Pharmacy, Chongqing Medical University, Chongqing, 400016, People's Republic of China.
| |
Collapse
|
42
|
Marinković Z, Gugliandolo G, Latino M, Campobello G, Crupi G, Donato N. Characterization and Neural Modeling of a Microwave Gas Sensor for Oxygen Detection Aimed at Healthcare Applications. SENSORS 2020; 20:s20247150. [PMID: 33322232 PMCID: PMC7764220 DOI: 10.3390/s20247150] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/11/2020] [Revised: 12/07/2020] [Accepted: 12/10/2020] [Indexed: 12/11/2022]
Abstract
The studied sensor consists of a microstrip interdigital capacitor covered by a gas sensing layer made of titanium dioxide (TiO2). To explore the gas sensing properties of the developed sensor, oxygen detection is considered as a case study. The sensor is electrically characterized using the complex scattering parameters measured with a vector network analyzer (VNA). The experimental investigation is performed over a frequency range of 1.5 GHz to 2.9 GHz by placing the sensor inside a polytetrafluoroethylene (PTFE) test chamber with a binary gas mixture composed of oxygen and nitrogen. The frequency-dependent response of the sensor is investigated in detail and further modelled using an artificial neural network (ANN) approach. The proposed modelling procedure allows mimicking the measured sensor performance over the whole range of oxygen concentration, going from 0% to 100%, and predicting the behavior of the resonant frequencies that can be used as sensing parameters.
Collapse
Affiliation(s)
- Zlatica Marinković
- Faculty of Electronic Engineering, University of Niš, Aleksandra Medvedeva 14, 18000 Niš, Serbia;
| | - Giovanni Gugliandolo
- MIFT Department, University of Messina, Viale F. Stagno d’Alcontres 31, 98166 Messina, Italy; (G.G.); (M.L.)
| | - Mariangela Latino
- MIFT Department, University of Messina, Viale F. Stagno d’Alcontres 31, 98166 Messina, Italy; (G.G.); (M.L.)
| | - Giuseppe Campobello
- Department of Engineering, University of Messina, Contrada di Dio, S. Agata, 98166 Messina, Italy; (G.C.); (N.D.)
| | - Giovanni Crupi
- BIOMORF Department, University of Messina, Via Consolare Valeria, 98100 Messina, Italy
- Correspondence:
| | - Nicola Donato
- Department of Engineering, University of Messina, Contrada di Dio, S. Agata, 98166 Messina, Italy; (G.C.); (N.D.)
| |
Collapse
|
43
|
Vernekar PR, Shetti NP, Shanbhag MM, Malode SJ, Malladi RS, Reddy KR. Novel layered structured bentonite clay-based electrodes for electrochemical sensor applications. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105441] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
|
44
|
Functional nanostructured metal oxides and its hybrid electrodes – Recent advancements in electrochemical biosensing applications. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105522] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
45
|
Fekry AM, Abdel‐Gawad SA, Azab SM, Walcarius A. A Sensitive Electrochemical Sensor for Moxifloxacin Hydrochloride Based on Nafion/Graphene Oxide/Zeolite Modified Carbon Paste Electrode. ELECTROANAL 2020. [DOI: 10.1002/elan.202060355] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Affiliation(s)
- Amany M. Fekry
- Chemistry Department, Faculty of Science Cairo University Giza 12613 Egypt
- Laboratoire de Chimie Physique et Microbiologie pour les Matériaux et l'Environnement (LCPME), UMR 7564 CNRS – Université de Lorraine 405 rue de Vandoeuvre 54600 Villers-les-Nancy France
| | | | - Shereen M. Azab
- Pharmaceutical Chemistry Dept. National Organization for Drug Control and Research [NODCAR] 6 Abu Hazem Street, Pyramids Ave, 29 Giza postcode is missing Egypt
| | - Alain Walcarius
- Laboratoire de Chimie Physique et Microbiologie pour les Matériaux et l'Environnement (LCPME), UMR 7564 CNRS – Université de Lorraine 405 rue de Vandoeuvre 54600 Villers-les-Nancy France
| |
Collapse
|
46
|
Naseri A, Hormozi-Nezhad MR, Shahrokhian S, Asadian E. Silver nanowires immobilized on gold-modified glassy carbon electrode for electrochemical quantification of atorvastatin. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114540] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
|
47
|
Lee EY, Kim Y, Koo B, Noh GS, Lee H, Shin Y. A novel nucleic acid amplification system based on nano-gap embedded active disk resonators. SENSORS AND ACTUATORS. B, CHEMICAL 2020; 320:128351. [PMID: 32501366 DOI: 10.1016/j.snb.2020.128391] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Revised: 05/15/2020] [Accepted: 05/21/2020] [Indexed: 05/28/2023]
Abstract
Recent advances in nucleic acid based testing using bio-optical sensor approaches have been introduced but most are based on hybridization between the optical sensor and the bio-molecule and not on an amplification mechanism. Direct nucleic acid amplification on an optical sensor has several technical limitations, such as the sensitivity of the temperature sensor, instrument complexity, and high background signal. We here describe a novel nucleic acid amplification method based on a whispering gallery mode active resonator and discuss its potential molecular diagnostic application. By implanting nanoclusters as active compounds, this active resonator operates without tapered fiber coupling and emits a strong photoluminescence signal with low background in the wavelength of low absorption in an aqueous environment that is typical of biosensors. Our method also offers an extremely low detection threshold down to a single copy within 10 min due to the strong light-matter interaction in a nano-gap structure. We envision that this active resonator provides a high refractive index contrast for tight mode confinement with simple alignment as well as the possibility of reducing the device size so that a point-of-care system with low-cost, high-sensitivity and simplicity.
Collapse
Affiliation(s)
- Eun Yeong Lee
- Department of Convergence Medicine, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea
| | - Yeseul Kim
- Department of Physics, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea
| | - Bonhan Koo
- Department of Convergence Medicine, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea
| | - Geun Su Noh
- Department of Convergence Medicine, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea
| | - Hansuek Lee
- Department of Physics, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea
- Graduate School of Nanoscience and Technology, Korea Advanced Institute of Science and Technology, Daejeon, 34141, Republic of Korea
| | - Yong Shin
- Department of Convergence Medicine, Asan Medical Institute of Convergence Science and Technology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, 05505, Republic of Korea
| |
Collapse
|
48
|
Kim S, Lee SM, Yoon JP, Lee N, Chung J, Chung WJ, Shin DS. Robust Magnetized Graphene Oxide Platform for In Situ Peptide Synthesis and FRET-Based Protease Detection. SENSORS (BASEL, SWITZERLAND) 2020; 20:E5275. [PMID: 32942708 PMCID: PMC7570466 DOI: 10.3390/s20185275] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/18/2020] [Revised: 09/10/2020] [Accepted: 09/14/2020] [Indexed: 11/17/2022]
Abstract
Graphene oxide (GO)/peptide complexes as a promising disease biomarker analysis platform have been used to detect proteolytic activity by observing the turn-on signal of the quenched fluorescence upon the release of peptide fragments. However, the purification steps are often cumbersome during surface modification of nano-/micro-sized GO. In addition, it is still challenging to incorporate the specific peptides into GO with proper orientation using conventional immobilization methods based on pre-synthesized peptides. Here, we demonstrate a robust magnetic GO (MGO) fluorescence resonance energy transfer (FRET) platform based on in situ sequence-specific peptide synthesis of MGO. The magnetization of GO was achieved by co-precipitation of an iron precursor solution. Magnetic purification/isolation enabled efficient incorporation of amino-polyethylene glycol spacers and subsequent solid-phase peptide synthesis of MGO to ensure the oriented immobilization of the peptide, which was evaluated by mass spectrometry after photocleavage. The FRET peptide MGO responded to proteases such as trypsin, thrombin, and β-secretase in a concentration-dependent manner. Particularly, β-secretase, as an important Alzheimer's disease marker, was assayed down to 0.125 ng/mL. Overall, the MGO platform is applicable to the detection of other proteases by using various peptide substrates, with a potential to be used in an automated synthesis system operating in a high throughput configuration.
Collapse
Affiliation(s)
- Seongsoo Kim
- Division of Chemical and Bioengineering, Kangwon National University, Gangwon-do 24341, Korea; (S.K.); (S.-M.L.); (J.P.Y.); (N.L.)
| | - Sang-Myung Lee
- Division of Chemical and Bioengineering, Kangwon National University, Gangwon-do 24341, Korea; (S.K.); (S.-M.L.); (J.P.Y.); (N.L.)
- Department of Research and Development, Cantis Inc., Ansan-si, Gyeonggi-do 15588, Korea
| | - Je Pil Yoon
- Division of Chemical and Bioengineering, Kangwon National University, Gangwon-do 24341, Korea; (S.K.); (S.-M.L.); (J.P.Y.); (N.L.)
| | - Namhun Lee
- Division of Chemical and Bioengineering, Kangwon National University, Gangwon-do 24341, Korea; (S.K.); (S.-M.L.); (J.P.Y.); (N.L.)
| | - Jinhyo Chung
- Department of Integrative Biotechnology, Sungkyunkwan University, Suwon 16419, Korea;
| | - Woo-Jae Chung
- Department of Integrative Biotechnology, Sungkyunkwan University, Suwon 16419, Korea;
| | - Dong-Sik Shin
- Department of Chemical and Biological Engineering, Sookmyung Women’s University, Yongsan-gu, Seoul 04310, Korea
- Industry Collaboration Center, Sookmyung Women’s University, Yongsan-gu, Seoul 04310, Korea
| |
Collapse
|
49
|
Janekarn I, Hunt AJ, Ngernyen Y, Youngme S, Supanchaiyamat N. Graphitic mesoporous carbon-silica composites from low-value sugarcane by-products for the removal of toxic dyes from wastewaters. ROYAL SOCIETY OPEN SCIENCE 2020; 7:200438. [PMID: 33047018 PMCID: PMC7540760 DOI: 10.1098/rsos.200438] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Accepted: 08/10/2020] [Indexed: 05/04/2023]
Abstract
Highly porous carbon-silica composites (CSC) were prepared for the first time through a simple wet impregnation process and subsequent pyrolysis of low-value sugarcane by-products, namely molasses. These CSC materials demonstrate a distinct range of functionalities, which significantly differ from similar materials published in the literature. Importantly, the carbon-silica composites prepared at 800°C exhibited exceptional adsorption capacities for the azo-dye congo red (445 mg g-1), due to the graphitic carbon coating and unique functionality including C-O-C within the porous structure. Congo red adsorption capacity of the highly mesoporous graphitic carbon-silica composites significantly exceeds that of commercial activated carbon and silica, these carbon-silica composites therefore represent an effective step towards the development of porous bio-derived adsorbent for remediation of dye wastewaters. Both the porous properties (surface area and pore size distribution) and the functionality of the carbon coating were dependent on the temperature of preparation. The sustainable synthetic methods employed led to a versatile material that inherited the mesoporosity characteristics from the parent silica, demonstrating mesoporous volumes greater than 90% (as calculated from the total pore volume). Adsorption on the 800°C prepared carbon-silica composites demonstrated an excellent fit with the Langmuir isotherm and the pseudo-first-order kinetic model.
Collapse
Affiliation(s)
- Intuorn Janekarn
- Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Andrew J. Hunt
- Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Yuvarat Ngernyen
- Department of Chemical Engineering, Faculty of Engineering, Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Sujittra Youngme
- Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Nontipa Supanchaiyamat
- Materials Chemistry Research Center, Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Khon Kaen University, Khon Kaen, 40002, Thailand
| |
Collapse
|
50
|
Singhal C, Shukla SK, Jain A, Pundir C, Khanuja M, Narang J, Shetti NP. Electrochemical Multiplexed Paper Nanosensor for Specific Dengue Serotype Detection Predicting Pervasiveness of DHF/DSS. ACS Biomater Sci Eng 2020; 6:5886-5894. [DOI: 10.1021/acsbiomaterials.0c00976] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Chaitali Singhal
- Amity Institute of Nanotechnology, Amity University, Noida, Uttar Pradesh 201313, India
- Translational Health Sciences and Technology Institute, Faridabad, Haryana 121001, India
| | - Sudheesh K. Shukla
- School of Environmental Science and Engineering, Shandong University, Jimo, Qingdao 266237, P. R. China
| | - Akshay Jain
- Amity Institute of Nanotechnology, Amity University, Noida, Uttar Pradesh 201313, India
- Translational Health Sciences and Technology Institute, Faridabad, Haryana 121001, India
| | - Chandrashekhar Pundir
- Department of Biochemistry, Maharishi Dayanand University, Rohtak, Haryana 124001, India
| | - Manika Khanuja
- Centre for Nanoscience and Nanotechnology, Jamia Millia Islamia, New Delhi 110025, India
| | - Jagriti Narang
- Department of Biotechnology, School of Chemical and Life Sciences, Jamia Hamdard (Deemed to Be University), Hamdard Nagar, New Delhi 110062, India
| | - Nagaraj P. Shetti
- Center for Electrochemical Science & Materials, Department of Chemistry, K.L.E. Institute of Technology, Opposite to Airport, Hubballi, Karnataka 580027, India
| |
Collapse
|