1
|
Impact of interdisciplinary counselling for parental decision-making in cases of pregnancies with prenatally diagnosed CHD. Cardiol Young 2023; 33:1172-1176. [PMID: 35915979 DOI: 10.1017/s104795112200213x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
INTRODUCTION Parental counselling after antenatal diagnosis of a congenital heart defect requires a high degree of professional and emotional competence and ultimately a sense of responsibility on the part of the consulting physicians. However, little is known about parents` perceptions and evaluation of these consultations. MATERIAL/METHODS Survey on 425 women who received interdisciplinary counselling after antenatal diagnosis of a complex fetal congenital heart defect in a specialized prenatal outpatient clinic with an affiliated paediatric heart centre. Two questionnaires were used to retrospectively evaluate the parental perception and impact on counselling, particularly on decision-making. Questionnaires differed between women conceiving the child and women who terminated the pregnancy. RESULTS 400 women continued, 25 women terminated the pregnancy after diagnosis and counselling. Good quality of life was reported for 68% of the children, 15% died postnatally in the further course. 95% rated the counselling as good or very good regardless of the child´s outcome. 73% described the counselling as highly important for their subsequent decision. The possibility of termination of pregnancy was discussed with 37% of the respondents, 22% of them found it outrageous or very distressing. Of all respondents, one woman would have made a different decision regarding continuation of the pregnancy in retrospect. CONCLUSION Retrospectively, parents rate prenatal counselling extremely positively, irrespective of the severity of the child´s heart defect. It can be assumed that the consistent joint interdisciplinary consultation and the high reputation of the cooperating heart centre have had an influence on the below-average rate of termination of pregnancy.
Collapse
|
2
|
Early Detection of Isolated Severe Congenital Heart Defects Is Associated with a Lower Threshold to Terminate the Pregnancy. Fetal Diagn Ther 2023; 50:248-258. [PMID: 37331329 PMCID: PMC10614269 DOI: 10.1159/000531583] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Accepted: 06/09/2023] [Indexed: 06/20/2023]
Abstract
INTRODUCTION Early detection of isolated severe congenital heart defects (CHDs) allows extra time for chromosomal analysis and informed decision making, resulting in improved perinatal management and patient satisfaction. Therefore, the aim of this study was to assess the value of an additional first-trimester screening scan compared to only a second-trimester scan in fetuses diagnosed with isolated severe CHDs. Prenatal detection rate, time of prenatal diagnosis, and pregnancy outcome were evaluated in the Netherlands after implementation of a national screening program. MATERIALS AND METHODS We performed a retrospective geographical cohort study and included 264 pre- and postnatally diagnosed isolated severe CHD cases between January 1, 2007, and December 31, 2015, in the Amsterdam region. Severe CHD was defined as potentially life threatening if intervention within the first year of life was required. Two groups were defined: those with a first- and second-trimester anomaly scan (group 1) and those with a second-trimester anomaly scan only (group 2). A first-trimester scan was defined as a scan between 11 + 0 and 13 + 6 weeks of gestation. RESULTS Overall, the prenatal detection rate for isolated severe CHDs was 65%; 63% were detected before 24 weeks of gestation (97% of all prenatally detected CHDs). Prenatal detection rate was 70.2% in the group with a first- and second-trimester scan (group 1) and 58% in the group with a second-trimester scan only (group 2) (p < 0.05). Median gestational age at detection was 19 + 6 (interquartile range [IQR] 15 + 4 - 20 + 5) in group 1 versus 20 + 3 (IQR: 20 + 0 - 21 + 1) in group 2 (p < 0.001). In group 1, 22% were diagnosed before 18 weeks of gestation. Termination of pregnancy rate in group 1 and group 2 were 48% and 27%, respectively (p < 0.01). Median gestational age at termination did not differ between the two groups. CONCLUSION Prenatal detection rate of isolated severe CHDs and termination of pregnancy rate was higher in the group with both a first- and second-trimester scan. We found no differences between timing of terminations. The additional time after diagnosis allows for additional genetic testing and optimal counseling of expectant parents regarding prognosis and perinatal management, so that well-informed decisions can be made.
Collapse
|
3
|
Decrease in perinatal mortality after closure of obstetric services in a community hospital in Amsterdam, The Netherlands. A retrospective cohort study. Eur J Obstet Gynecol Reprod Biol 2023; 284:189-199. [PMID: 37028203 DOI: 10.1016/j.ejogrb.2023.03.034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2023] [Revised: 03/08/2023] [Accepted: 03/28/2023] [Indexed: 03/31/2023]
Abstract
OBJECTIVE To assess differences in adverse maternal and neonatal outcomes before and after closure of a secondary obstetric care unit of a community hospital in an urban district. STUDY DESIGN Retrospective cohort study using aggregated data from National Perinatal Registry of the Netherlands (PERINED) in the very urban region of Amsterdam, consisting of data of five secondary and two tertiary hospitals. We assessed maternal and neonatal outcomes in singleton hospital births between 24+0 weeks of gestational age (GA) up to 42+6 weeks. Data of 78.613 births were stratified in two groups: before closure (years 2012-2015) and after closure (2016-2019). RESULTS Perinatal mortality decreased significantly from 0.84 % to 0.63 % (p = 0.0009). The adjusted odds ratio (aOR) of the closure on perinatal mortality was 0.73 (95 % CI 0.62-0.87). Both antepartum death (0.46 % vs 0.36 %, p = 0.02) and early neonatal death (0.38 % vs 0.28 %, p = 0.015) declined after closure of the hospital. The number of preterm births decreased significantly (8.7 % vs 8.1 %, p=<0.007) as well as number of neonates with congenital abnormalities (3.2 % vs2.2 %, p=<0.0001). APGAR < 7 after 5 min increased (2.3 % vs 2.5 %, p = 0.04). There was no significant difference in SGA or NICU admission. Postpartum hemorrhage increased significantly from 7.7 % to 8.2 % (p=<0.003). Perinatal mortality from 32 weeks onwards was not significantly different after closure 0.29 % to 0.27 %. CONCLUSIONS After closure of an obstetric unit in a community hospital in Amsterdam, there was a significant decrease in perinatal, intrapartum and early neonatal mortality in neonates born from 24+0 onwards. The mortality decrease coincides with a reduction of preterm deliveries. The increasing trend in asphyxia and postpartum hemorrhage is of concern.. Centralization of care and increasing birth volume per hospital may lead to improvement of quality of care. A broad integrated, multidisciplinary maternity healthcare system linked with the social domain can achieve health gains in maternity care for all women.
Collapse
|
4
|
Gestational age-specific neonatal mortality in Hong Kong: a population-based retrospective study. World J Pediatr 2023; 19:158-169. [PMID: 36409452 DOI: 10.1007/s12519-022-00633-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Accepted: 10/05/2022] [Indexed: 11/22/2022]
Abstract
BACKGROUND The neonatal period is the most vulnerable period during childhood, with the risk of death being the highest even in developed countries/regions. Hong Kong's neonatal mortality (1‰) is among the world's lowest and has remained similar for 15 years. This study aimed to explore neonatal deaths in Hong Kong in detail and determine whether neonatal mortality is reducible at such a low level. METHODS Live births in public hospitals in Hong Kong during 01 Jan 2006-31 Dec 2017 were included. Relevant data were extracted from the electronic medical records. Gestational age-specific mortality was calculated, and the trends were analyzed using the Cochran-Armitage trend test. Causes of death were summarized, and risk factors were identified in multivariate logistic regression analysis. RESULTS In 490,034 live births, 755 cases (1.54‰) died during the neonatal period, and 293 (0.6‰) died during the post-neonatal period. The neonatal mortality remained similar overall (P = 0.17) and among infants born at 24-29 weeks' gestation (P = 0.4), while it decreased in those born at 23 (P = 0.04), 30-36 (P < 0.001) and ≥ 37 (P < 0.001) weeks' gestation. Neonates born at < 27 weeks' gestation accounted for a significantly increased proportion among cases who died (27.6% to 51.9%), with hemorrhagic conditions (24%) being the leading cause of death. Congenital anomalies were the leading cause of death in neonates born ≥ 27 weeks' gestation (52%), but its cause-specific mortality decreased (P = 0.002, 0.6‰ to 0.41‰), with most of the decrease attributed to trisomy 13/18 and multiple anomalies. CONCLUSION Reduction of neonatal mortality in developed regions may heavily rely on improved quality of perinatal and neonatal care among extremely preterm infants.
Collapse
|
5
|
Prenatal detection of aortic coarctation in a well-organized screening setting: Are we there yet? Prenat Diagn 2022; 43:620-628. [PMID: 36549919 DOI: 10.1002/pd.6291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2022] [Revised: 11/05/2022] [Accepted: 12/17/2022] [Indexed: 12/24/2022]
Abstract
OBJECTIVE We aimed to assess current prenatal detection rate (DR) of aortic coarctation (CoA) and its impact on neonatal outcome in the Netherlands to evaluate the efficacy of the Dutch screening protocol in which the cardiac four-chamber view, outflow tracts and three-vessel view are compulsory. METHODS All prenatally and postnatally diagnosed CoA cases between 2012 and 2021 were extracted from our PRECOR-registry. Annual DRs were calculated with a focus on the trend over time and attributing factors for detection. Postnatal outcome was compared between prenatally detected and undetected cases. RESULTS 49/116 cases (42.2%) were detected prenatally. A higher chance of detection was found for cases with extracardiac malformations (71.4%; p = 0.001) and the more severe cases with an aortic arch hypoplasia and/or ventricular septal defect (63.2%; p = 0.001). Time-trend analysis showed no improvement in DR over time (p = 0.33). Undetected cases presented with acute circulatory shock in 20.9% and were more likely to have severe lactic acidosis (p = 0.02) and impaired cardiac function (p < 0.001) before surgery. CONCLUSION Even in a well-organized screening program, the DR of CoA still requires improvement, especially in isolated cases. The increased risk of severe lactic acidosis in undetected cases stresses the need for urgent additions to the current screening program, such as implementation of the three-vessel trachea view and measurement of outflow tracts.
Collapse
|
6
|
Stillbirth in term and late term gestations in Stockholm during a 20-year period, incidence and causes. PLoS One 2021; 16:e0251965. [PMID: 34033674 PMCID: PMC8148351 DOI: 10.1371/journal.pone.0251965] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2021] [Accepted: 05/06/2021] [Indexed: 11/26/2022] Open
Abstract
Introduction The incidence of stillbirth has decreased marginally or remained stable during the past decades in high income countries. A recent report has shown Stockholm to have a lower incidence of stillbirth at term than other parts of Sweden. The risk of antepartum stillbirth increases in late term and postterm pregnancies which is one of the factors contributing to the current discussion regarding the optimal time of induction of labor due to postterm pregnancy. Material and methods This is a cohort study based on the Stockholm Stillbirth Database which contains all cases of stillbirth from 1998-2018 in Stockholm County. All cases were reviewed systematically and the cause of death was evaluated according to the Stockholm Stillbirth Classification. Stillbirths diagnosed between gestational week (GW) 37+0 and 40+6 n = 605 were compared to stillbirths diagnosed from GW 41+0 and onwards n = 157, according to the cause of stillbirth and pregnancy and maternal characteristics. The aim was to evaluate the incidence of stillbirth over time and the incidence of stillbirth diagnosed from GW 41+0. Results In Stockholm County the overall incidence of stillbirth has decreased from 4.6/1000 births during the period 1998-2004 to 3.4/1000 births during the period 2014-2018, p-value <0.001. When comparing the same time periods, the incidence of stillbirth diagnosed from GW 41+0 and onwards has decreased from 0.5/1000 births to 0.15/1000 births, p-value <0.001. Among women still pregnant at GW 41+0 the incidence of stillbirth has decreased from 1.8/ 1000 to 0.5/ 1000. When comparing stillbirths diagnosed at GW 37+0-40+6 with stillbirths diagnosed from GW 41+0 and onwards infection was a more common cause of stillbirth in the latter group. Conclusion In Stockholm County there was a decreasing incidence of stillbirth overall and in stillbirths diagnosed from 41+0 weeks of gestation and onwards during the period 1998-2018. In stillbirths diagnosed from GW 41+0 and onwards infection was a more common cause of death compared to stillbirths diagnosed between GW 37+0 and 40+6.
Collapse
|
7
|
Why are congenital heart defects being missed? ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2020; 55:747-757. [PMID: 31131945 PMCID: PMC7317409 DOI: 10.1002/uog.20358] [Citation(s) in RCA: 54] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2019] [Revised: 05/14/2019] [Accepted: 05/20/2019] [Indexed: 05/10/2023]
Abstract
OBJECTIVE Congenital heart defects (CHD) are still missed frequently in prenatal screening programs, which can result in severe morbidity or even death. The aim of this study was to evaluate the quality of fetal heart images, obtained during the second-trimester standard anomaly scan (SAS) in cases of CHD, to explore factors associated with a missed prenatal diagnosis. METHODS In this case-control study, all cases of a fetus born with isolated severe CHD in the Northwestern region of The Netherlands, between 2015 and 2016, were extracted from the PRECOR registry. Severe CHD was defined as need for surgical repair in the first year postpartum. Each cardiac view (four-chamber view (4CV), three-vessel (3V) view and left and right ventricular outflow tract (LVOT, RVOT) views) obtained during the SAS was scored for technical correctness on a scale of 0 to 5 by two fetal echocardiography experts, blinded to the diagnosis of CHD and whether it was detected prenatally. Quality parameters of the cardiac examination were compared between cases in which CHD was detected and those in which it was missed on the SAS. Regression analysis was used to assess the association of sonographer experience and of screening-center experience with the cardiac examination quality score. RESULTS A total of 114 cases of isolated severe CHD at birth were analyzed, of which 58 (50.9%) were missed and 56 (49.1%) were detected on the SAS. The defects comprised transposition of the great arteries (17%), aortic coarctation (16%), tetralogy of Fallot (10%), atrioventricular septal defect (6%), aortic valve stenosis (5%), ventricular septal defect (18%) and other defects (28%). No differences were found in fetal position, obstetric history, maternal age or body mass index (BMI) or gestational age at examination between missed and detected cases. Ninety-two cases had available cardiac images from the SAS. Compared with the detected group, the missed group had significantly lower cardiac examination quality scores (adequate score (≥ 12) in 32% vs 64%; P = 0.002), rate of proper use of magnification (58% vs 84%; P = 0.01) and quality scores for each individual cardiac plane (4CV (2.7 vs 3.9; P < 0.001), 3V view (3.0 vs 3.8; P = 0.02), LVOT view (1.9 vs 3.3; P < 0.001) and RVOT view (1.9 vs 3.3; P < 0.001)). In 49% of missed cases, the lack of detection was due to poor adaptational skills resulting in inadequate images in which the CHD was not clearly visible; in 31%, the images showed an abnormality (mainly septal defects and aortic arch anomalies) which had not been recognized at the time of the scan; and, in 20%, the cardiac planes had been obtained properly but showed normal anatomy. Multivariate regression analysis showed that the volume of SAS performed per year by each sonographer was associated significantly with quality score of the cardiac examination. CONCLUSIONS A lack of adaptational skills when performing the SAS, as opposed to circumstantial factors such as BMI or fetal position, appears to play an important role in failure to detect CHD prenatally. The quality of the cardiac views was inadequate significantly more often in undetected compared with detected cases. Despite adequate quality of the images, CHD was not recognized in 31% of cases. A high volume of SAS performed by each sonographer in a large ultrasound center contributes significantly to prenatal detection. In 20% of undetected cases, CHD was not visible even though the quality of the images was good. © 2019 Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
Collapse
|
8
|
From sub-microscopic variants to the resolution of a single base pair: Exome sequencing in prenatal diagnosis. Eur J Med Genet 2019; 63:103779. [PMID: 31586466 DOI: 10.1016/j.ejmg.2019.103779] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2019] [Revised: 09/30/2019] [Accepted: 10/01/2019] [Indexed: 10/25/2022]
|
9
|
Abstract
OBJECTIVES To assess international trends and patterns of prenatal diagnosis of critical congenital heart defects (CCHDs) and their relation to total and live birth CCHD prevalence and mortality. SETTING Fifteen birth defect surveillance programmes that participate in the International Clearinghouse for Birth Defects Surveillance and Research from 12 countries in Europe, North and South America and Asia. PARTICIPANTS Live births, stillbirths and elective terminations of pregnancy for fetal anomaly diagnosed with 1 of 12 selected CCHD, ascertained by the 15 programmes for delivery years 2000 to 2014. RESULTS 18 243 CCHD cases were reported among 8 847 081 births. The median total prevalence was 19.1 per 10 000 births but varied threefold between programmes from 10.1 to 31.0 per 10 000. CCHD were prenatally detected for at least 50% of the cases in one-third of the programmes. However, prenatal detection varied from 13% in Slovak Republic to 87% in some areas in France. Prenatal detection was consistently high for hypoplastic left heart syndrome (64% overall) and was lowest for total anomalous pulmonary venous return (28% overall). Surveillance programmes in countries that do not legally permit terminations of pregnancy tended to have higher live birth prevalence of CCHD. Most programmes showed an increasing trend in prenatally diagnosed CCHD cases. DISCUSSION AND CONCLUSIONS Prenatal detection already accounts for 50% or more of CCHD detected in many programmes and is increasing. Local policies and access likely account for the wide variability of reported occurrence and prenatal diagnosis. Detection rates are high especially for CCHD that are more easily diagnosed on a standard obstetric four-chamber ultrasound or for fetuses that have extracardiac anomalies. These ongoing trends in prenatal diagnosis, potentially in combination with newborn pulse oximetry, are likely to modify the epidemiology and clinical outcomes of CCHD in the near future.
Collapse
|
10
|
|
11
|
The effect of the introduction of the three-vessel view on the detection rate of transposition of the great arteries and tetralogy of Fallot. Prenat Diagn 2018; 38:951-957. [PMID: 30132937 DOI: 10.1002/pd.5347] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2018] [Revised: 08/08/2018] [Accepted: 08/12/2018] [Indexed: 12/19/2022]
Abstract
OBJECTIVES The aim of this study was to analyze the annual detection rate (DR) of transposition of the great arteries (TGA) and tetrology of Fallot (ToF), after the introduction of the three-vessel view as a mandatory plane in 2012. METHODS All registered TGA and ToF cases were retrospectively extracted from our registry between 2007 and 2016. We compared the DR in a 10-year period, before 2011, with the DR of TGA and ToF after 2012. RESULTS In the period before 2012, 23 of the 52 TGA cases were prenatally detected (44.2%), compared with 42 of the 51 cases (82.4%) after 2012. For ToF, the DRs increased from 28 of 64 cases (43.8%) to 42 of 62 cases (67.7%) in the aforementioned periods. The increase in DRs for both defects was statistically significant (P ≤ 0.001 and P ≤ 0.05). CONCLUSIONS In this nationally organized prenatal screening program with a quality monitoring system and a uniform protocol, DRs of 82.4% for TGA and 67.7% for ToF were reached after the introduction of the three-vessel view as a mandatory item. The three-vessel view significantly contributes to the detection of these conotruncal anomalies.
Collapse
|
12
|
Abstract
Fetal structural anomalies are found in up to 3% of all pregnancies and ultrasound-based screening has been an integral part of routine prenatal care for decades. The prenatal detection of fetal anomalies allows for optimal perinatal management, providing expectant parents with opportunities for additional imaging, genetic testing, and the provision of information regarding prognosis and management options. Approximately one-half of all major structural anomalies can now be detected in the first trimester, including acrania/anencephaly, abdominal wall defects, holoprosencephaly and cystic hygromata. Due to the ongoing development of some organ systems however, some anomalies will not be evident until later in the pregnancy. To this extent, the second trimester anatomy is recommended by professional societies as the standard investigation for the detection of fetal structural anomalies. The reported detection rates of structural anomalies vary according to the organ system being examined, and are also dependent upon factors such as the equipment settings and sonographer experience. Technological advances over the past two decades continue to support the role of ultrasound as the primary imaging modality in pregnancy, and the safety of ultrasound for the developing fetus is well established. With increasing capabilities and experience, detailed examination of the central nervous system and cardiovascular system is possible, with dedicated examinations such as the fetal neurosonogram and the fetal echocardiogram now widely performed in tertiary centers. Magnetic resonance imaging (MRI) is well recognized for its role in the assessment of fetal brain anomalies; other potential indications for fetal MRI include lung volume measurement (in cases of congenital diaphragmatic hernia), and pre-surgical planning prior to fetal spina bifida repair. When a major structural abnormality is detected prenatally, genetic testing with chromosomal microarray is recommended over routine karyotype due to its higher genomic resolution.
Collapse
|
13
|
Use of hierarchical models to analyze European trends in congenital anomaly prevalence. ACTA ACUST UNITED AC 2017; 106:480-8. [PMID: 27301561 DOI: 10.1002/bdra.23515] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2016] [Accepted: 03/23/2016] [Indexed: 11/11/2022]
Abstract
BACKGROUND Surveillance of congenital anomalies is important to identify potential teratogens. Despite known associations between different anomalies, current surveillance methods examine trends within each subgroup separately. We aimed to evaluate whether hierarchical statistical methods that combine information from several subgroups simultaneously would enhance current surveillance methods using data collected by EUROCAT, a European network of population-based congenital anomaly registries. METHODS Ten-year trends (2003 to 2012) in 18 EUROCAT registries over 11 countries were analyzed for the following groups of anomalies: neural tube defects, congenital heart defects, digestive system, and chromosomal anomalies. Hierarchical Poisson regression models that combined related subgroups together according to EUROCAT's hierarchy of subgroup coding were applied. Results from hierarchical models were compared with those from Poisson models that consider each congenital anomaly separately. RESULTS Hierarchical models gave similar results as those obtained when considering each anomaly subgroup in a separate analysis. Hierarchical models that included only around three subgroups showed poor convergence and were generally found to be over-parameterized. Larger sets of anomaly subgroups were found to be too heterogeneous to group together in this way. CONCLUSION There were no substantial differences between independent analyses of each subgroup and hierarchical models when using the EUROCAT anomaly subgroups. Considering each anomaly separately, therefore, remains an appropriate method for the detection of potential changes in prevalence by surveillance systems. Hierarchical models do, however, remain an interesting alternative method of analysis when considering the risks of specific exposures in relation to the prevalence of congenital anomalies, which could be investigated in other studies. Birth Defects Research (Part A) 106:480-10, 2016. © 2016 Wiley Periodicals, Inc.
Collapse
|
14
|
The Outcome of Prenatally Diagnosed Isolated Fetal Ventricular Septal Defect. J Med Ultrasound 2017; 25:71-75. [PMID: 30065463 PMCID: PMC6029313 DOI: 10.1016/j.jmu.2017.05.005] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2017] [Accepted: 05/15/2017] [Indexed: 12/13/2022] Open
|
15
|
An Audit of Second-Trimester Fetal Anomaly Scans Based on a Novel Image-Scoring Method in the Southwest Region of the Netherlands. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2017; 36:1171-1179. [PMID: 28299806 DOI: 10.7863/ultra.16.06055] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2016] [Accepted: 09/06/2016] [Indexed: 06/06/2023]
Abstract
OBJECTIVES Since 2007 the second-trimester fetal anomaly scan is offered to all pregnant women as part of the national prenatal screening program in the Netherlands. Dutch population-based screening programs generally have a well-described system to achieve quality assurance. Because of the absence of a uniform system to monitor the actual performance of the fetal anomaly scan in 2012, we developed a standardized image-scoring method. The aim of this study was to evaluate the scanning performance of all sonographers in the southwestern region of the Netherlands using this image-scoring method. METHODS Each sonographer was requested to set up a digital portfolio. A portfolio consists of five logbooks from five different pregnant women, each containing 25 fetal anatomical structures and six biometric measures of randomly selected fetal anomaly scans. RESULTS During the study period, 425 logbooks of 85 sonographers were assessed as part of the audit process. Seventy-three out of 85 sonographers (86%) met the criteria in the primary audit, and 12 sonographers required individual hands-on training. A successful assessment was achieved for 11 sonographers in the re-audit and one sonographer ceased her contract. Moreover, 2.1% of the required images were not digitally stored and therefore could not be reviewed. CONCLUSIONS Quality assessment using the image-scoring method demonstrated that most of the sonographers met the expectations of the audit process, but those who had subpar performance met the expectations after retraining.
Collapse
|
16
|
|
17
|
How to Acquire Cardiac Volumes for Sonographic Examination of the Fetal Heart: Part 2. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2016; 35:1043-66. [PMID: 27091912 PMCID: PMC8475629 DOI: 10.7863/ultra.16.01082] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2016] [Accepted: 03/13/2016] [Indexed: 05/04/2023]
Abstract
The effective performance of fetal cardiac examination using spatiotemporal image correlation (STIC) technology requires 2 essential steps: volume acquisition and postprocessing. An important prerequisite is training sonologists to acquire high-quality volume data sets so that when analyzed, such volumes are informative. This article is part 2 of a series on 4-dimensional sonography with STIC. Part 1 focused on STIC technology and its features, the importance of operator training/experience and acquisition of high-quality STIC volumes, factors that affect STIC volume acquisition rates, and general recommendations on performing 4D sonography with STIC. In part 2, we discuss a detailed and practical stepwise approach for STIC volume acquisition, along with methods to determine whether such volumes are appropriate for analysis.
Collapse
|
18
|
How to Acquire Cardiac Volumes for Sonographic Examination of the Fetal Heart: Part 1. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2016; 35:1021-42. [PMID: 27091914 PMCID: PMC8475630 DOI: 10.7863/ultra.16.01081] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2016] [Accepted: 02/29/2016] [Indexed: 05/13/2023]
Abstract
Four-dimensional sonography with spatiotemporal image correlation (STIC) technology allows acquisition of a fetal cardiac volume data set and displays a cine loop of a complete single cardiac cycle in motion. Part 1 of this 2-part article reviews STIC technology and its features, the importance of operator training/experience, and acquisition of high-quality STIC volumes, as well as factors that affect STIC volume acquisition rates. We also propose a detailed and practical stepwise approach to performing 4-dimensional sonography with STIC and begin herein by providing general recommendations. Part 2 will discuss specifics of the approach, along with how to determine whether such volumes are appropriate for analysis.
Collapse
|
19
|
Declines in stillbirth and neonatal mortality rates in Europe between 2004 and 2010: results from the Euro-Peristat project. J Epidemiol Community Health 2015; 70:609-15. [PMID: 26719590 PMCID: PMC4893141 DOI: 10.1136/jech-2015-207013] [Citation(s) in RCA: 59] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2015] [Accepted: 12/01/2015] [Indexed: 12/02/2022]
Abstract
Background Stillbirth and neonatal mortality rates declined in Europe between 2004 and 2010. We hypothesised that declines might be greater for countries with higher mortality in 2004 and disproportionally affect very preterm infants at highest risk. Methods Data about live births, stillbirths and neonatal deaths by gestational age (GA) were collected using a common protocol by the Euro-Peristat project in 2004 and 2010. We analysed stillbirths at ≥28 weeks GA in 22 countries and live births ≥24 weeks GA for neonatal mortality in 18 countries. Per cent changes over time were assessed by calculating risk ratios (RR) for stillbirth, neonatal mortality and preterm birth rates in 2010 vs 2004. We used meta-analysis techniques to derive pooled RR using random-effects models overall, by GA subgroups and by mortality level in 2004. Results Between 2004 and 2010, stillbirths declined by 17% (95% CI 10% to 23%), with a range from 1% to 39% by country. Neonatal mortality declined by 29% (95% CI 23% to 35%) with a range from 9% to 67%. Preterm birth rates did not change: 0% (95% CI −3% to 3%). Mortality declines were of a similar magnitude at all GA; mortality levels in 2004 were not associated with RRs. Conclusions Stillbirths and neonatal deaths declined at all gestational ages in countries with both high and low levels of mortality in 2004. These results raise questions about how low-mortality countries achieve continued declines and highlight the importance of improving care across the GA spectrum.
Collapse
|