1
|
Diepeveen-de Bruin M, Maho W, Buso MEC, Naomi ND, Brouwer-Brolsma EM, Feskens EJM, Balvers MGJ. Development and validation of a UPLC-MS/MS method for the quantification of sugars and non-nutritive sweeteners in human urine. J Chromatogr B Analyt Technol Biomed Life Sci 2023; 1225:123741. [PMID: 37236072 DOI: 10.1016/j.jchromb.2023.123741] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 05/04/2023] [Accepted: 05/06/2023] [Indexed: 05/28/2023]
Abstract
High-intensity sweeteners ('sweeteners'), such as sucralose, saccharine, acesulfame, cyclamate and steviol, are replacing sugars in many food products, but biomarker-based data on their population-wide exposure, as well as analytical methods that can quantify urinary concentrations of sugars and sweeteners simultaneously, are lacking. Here, we developed and validated an ultra-pressure liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) method to quantify glucose, sucrose, fructose, sucralose, saccharine, acesulfame, cyclamate and steviol glucuronide in human urine. Urine samples were prepared by a simple dilution step containing the internal standards in water and methanol. Separation was achieved on a Shodex Asahipak NH2P-40 hydrophilic interaction liquid chromatography (HILIC) column using gradient elution. The analytes were detected using electrospray ionization in negative ion mode, and selective reaction monitoring was optimized using the [M-H]- ions. Calibration curves ranged between 34 and 19,230 ng/mL for glucose and fructose, and 1.8 to 1,026 ng/mL for sucrose and the sweeteners. The method has acceptable accuracy and precision, which depends on the application of appropriate internal standards. Storage of urine samples in lithium monophosphate gives the best overall analytical performance, and storage at room temperature without any preservatives should be avoided since this leads to reduced glucose and fructose concentrations. With the exception of fructose, all analytes were stable throughout 3 freeze-thaw cycles. The validated method was applied to human urine samples, demonstrating quantifiable concentrations of the analytes which were in the expected range. It is concluded that the method has acceptable performance to quantitatively determine dietary sugars and sweeteners in human urine.
Collapse
Affiliation(s)
- Marlies Diepeveen-de Bruin
- Division of Human Nutrition and Health, Wageningen University & Research, P.O. Box 17, 6700 AA Wageningen, the Netherlands.
| | - Walid Maho
- Division of Human Nutrition and Health, Wageningen University & Research, P.O. Box 17, 6700 AA Wageningen, the Netherlands.
| | - Marion E C Buso
- Division of Human Nutrition and Health, Wageningen University & Research, P.O. Box 17, 6700 AA Wageningen, the Netherlands.
| | - Novita D Naomi
- Division of Human Nutrition and Health, Wageningen University & Research, P.O. Box 17, 6700 AA Wageningen, the Netherlands.
| | - Elske M Brouwer-Brolsma
- Division of Human Nutrition and Health, Wageningen University & Research, P.O. Box 17, 6700 AA Wageningen, the Netherlands.
| | - Edith J M Feskens
- Division of Human Nutrition and Health, Wageningen University & Research, P.O. Box 17, 6700 AA Wageningen, the Netherlands.
| | - Michiel G J Balvers
- Division of Human Nutrition and Health, Wageningen University & Research, P.O. Box 17, 6700 AA Wageningen, the Netherlands.
| |
Collapse
|
2
|
Li F, Xing G, Cousineau C, Clemens S, Mofikoya M, Kim MY, Zhang JY, Zhang Y, Raha N. Development and validation of a HILIC-MS/MS method for the quantitation of fructose in human urine in support of clinical programs. J Pharm Biomed Anal 2022; 208:114462. [PMID: 34798390 DOI: 10.1016/j.jpba.2021.114462] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Revised: 10/20/2021] [Accepted: 11/02/2021] [Indexed: 10/19/2022]
Abstract
In a previous publication [1], a 20-minute UPLC®-MS/MS method, employing a surrogate analyte approach, was developed and validated to measure fructose and sorbitol, as mechanistic biomarkers, in human plasma to support first-in-human (FIH) studies. Different from plasma which maintains its homeostasis, urine has no such homeostasis mechanisms [2], therefore it is expected to be able to accommodate more changes. Here we describe the development and validation of a LC-MS/MS method for the quantiation of fructose in human urine to support clinical trials. A hydrophilic interaction chromatography (HILIC) method using an Asahipak NH2P-50 column (Shodex, 4.6 × 250 mm, 5 µm) was developed. Acetone precipitation was utilized to extract fructose from urine. For validation, stable isotope-labeled 13C6-fructose was used as the surrogate analyte for fructose in the preparation of calibration curves. QCs were prepared using both the surrogate analyte (13C6-fructose) and the authentic analyte (fructose). Difficulties were encountered for post-extraction stability experiments especially for authentic fructose QCs at low concentrations. Extensive troubleshooting revealed that fructose's chromatography improved as the column aged. As a result, the response factor of fructose increased over time for low concentration samples, leading to failed post-extraction stability experiments. A column cleaning procedure was implemented to ensure consistency in chromatography performance. The HILIC-MS/MS method was successfully validated and applied to analyze clinical samples with a 91% overall run passing rate.
Collapse
Affiliation(s)
- Fumin Li
- PPD Lab, 3230 Deming Way, Middleton, WI 53562, USA
| | - Gang Xing
- Internal Medicine Research Unit Pfizer, Inc, 610 Main Street, Cambridge, MA 02139, USA
| | | | - Sara Clemens
- PPD Lab, 3230 Deming Way, Middleton, WI 53562, USA
| | | | | | - Jenny Yanhua Zhang
- Clinical Biomarker Sciences Group Precision Medicine Early Clinical Development Pfizer Inc, 610 Main Street, Cambridge, MA 02139, USA
| | - Yizhong Zhang
- Clinical Assay Group Clinical Pharmacology Global Product Development Pfizer, Inc, 445 Eastern Point Road, Groton, CT 06340, USA
| | - Nancy Raha
- Clinical Assay Group Clinical Pharmacology Global Product Development Pfizer, Inc, 445 Eastern Point Road, Groton, CT 06340, USA.
| |
Collapse
|
3
|
Venkataseetharaman A, Mishra G, Ghosh MK, Das GK. Role of Glycerol Oxidation Pathways in the Reductive Acid Leaching Kinetics of Manganese Nodules Using Glycerol. ACS OMEGA 2021; 6:14903-14910. [PMID: 34151072 PMCID: PMC8209816 DOI: 10.1021/acsomega.1c00730] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Accepted: 05/28/2021] [Indexed: 06/13/2023]
Abstract
Manganese nodules from ocean bed are potential resources of Cu, Ni, and Co for which land-based deposits are scarce in India. The present work describes a novel approach of using glycerol, a nontoxic biomass-derived reductant, for the reductive acid leaching of manganese nodules. Parameters such as acid concentration, time, temperature, and pulp density were optimized for leaching. The optimal leaching conditions were found to be 10% (w/v) pulp density and 10% (v/v) H2SO4 at 80 °C with 1% (v/v) glycerol yielding >95% of Ni and >98% Cu, Co, and Mn extraction within an hour. Kinetic analysis of the data based on the initial rate method showed that the leaching process was chemical reaction-controlled with an apparent activation energy of 55.47 kJ/mol. Various oxidation intermediates of glycerol formed during leaching were identified using mass spectrometry and Raman spectroscopy, and a probable oxidation pathway of glycerol during the leaching process has been elucidated based on the analysis. Glycerol was oxidized to glyceraldehyde, glyceric acid, tartronic acid, dihydroxyacetone, hydroxy pyruvic acid, glyoxalic acid, oxalic acid, and finally converted to CO2 during leaching. The fast reaction kinetics, near-complete dissolution of manganese, and other associated metals in the nodule can be attributed to the participation of all intermediate products of glycerol oxidation in redox reactions with MnO2, enhancing the overall reduction leaching efficiency.
Collapse
Affiliation(s)
- Aishvarya Venkataseetharaman
- Academy
of Scientific and Innovative Research (AcSIR), CSIR-Institute of Minerals and Materials Technology Campus, Bhubaneswar 751013, India
- Hydro
& Electrometallurgy Department, CSIR-Institute
of Minerals and Materials Technology, Bhubaneswar 751013, India
| | - Geetanjali Mishra
- Hydro
& Electrometallurgy Department, CSIR-Institute
of Minerals and Materials Technology, Bhubaneswar 751013, India
| | - Malay Kumar Ghosh
- Academy
of Scientific and Innovative Research (AcSIR), CSIR-Institute of Minerals and Materials Technology Campus, Bhubaneswar 751013, India
- Hydro
& Electrometallurgy Department, CSIR-Institute
of Minerals and Materials Technology, Bhubaneswar 751013, India
| | - Goutam Kumar Das
- CSIRO
Mineral Resources, 7 Conlon Street, Waterford, Western Australia 6152, Australia
| |
Collapse
|
4
|
Makino Y, Urano Y, Kaneko K. Trial analysis of drug profiling by liquid chromatography/mass spectrometry and inductively coupled plasma mass spectrometry to establish the origin of ephedrines used as precursors for illicit production of methamphetamine. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2019; 33:995-1005. [PMID: 30849207 DOI: 10.1002/rcm.8429] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2018] [Revised: 03/01/2019] [Accepted: 03/02/2019] [Indexed: 06/09/2023]
Abstract
RATIONALE We investigated whether chemical information on the origin of ephedrine and pseudoephedrine (ephedrines) can be acquired by liquid chromatography/mass spectrometry (LC/MS) as a substitute method for stable isotope ratio mass spectrometry (IRMS), which is not routinely available in forensic laboratories. We examined the characteristic inorganic elemental contaminants of ephedrines as a preliminary study. METHODS The stable isotope ratios measured by IRMS analysis are expressed relative to the stable isotope ratios of conventional standards. Referring to the method using validated standard samples in IRMS, we selected a standard sample for acquiring stable isotopic ratio by LC/MS. The abundance ratio of the [M + 2H]+ ion to the [M + H]+ ion was measured by means of selected ion monitoring. We carried out qualitative analysis of inorganic elements contained in ephedrines produced by different manufacturing methods with ICPMS. RESULTS We found that the ratio of stable isotope ion to molecular ion (stable isotope ratio) of ephedrines could be measured with LC/MS. The stable isotope ratio of ephedrines determined by LC/MS were confirmed to show relatively good correlations with the carbon and hydrogen stable isotope ratios found by IR-MS. We identified strontium as a characteristic inorganic element contained in ephedrines prepared by the semisynthetic method from molasses, or in the biosynthetic method from ephedra plants. CONCLUSIONS Our results suggest that useful chemical information can be obtained by LC/MS, which is easy to carry out, and is generally available in forensic laboratories. It would be worthwhile to investigate the usefulness of stable isotope ratio measurements of Sr in the future.
Collapse
Affiliation(s)
- Yukiko Makino
- Graduate School of Pharmaceutical Sciences, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Yasuteru Urano
- Graduate School of Pharmaceutical Sciences, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-0033, Japan
| | - Kiyoko Kaneko
- Faculty of Pharma-Science, Teikyo University, 2-11-1 Kaga, Itabashi-ku, Tokyo, 173-8605, Japan
| |
Collapse
|
5
|
Freudenheim JL, Shields PG, Song MA, Smiraglia D. DNA Methylation and Smoking: Implications for Understanding Effects of Electronic Cigarettes. CURR EPIDEMIOL REP 2019. [DOI: 10.1007/s40471-019-00191-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
6
|
Lee SY, Kim K, Kwon HS, Kim YE, Kim KY, Jeong J, Oh HB, Kim TY, Hong J, Kang D. Development of Triglyceride Certified Reference Materials in Human Frozen Serum Using Isotope Dilution‐Liquid Chromatography–Tandem Mass Spectrometry. B KOREAN CHEM SOC 2019. [DOI: 10.1002/bkcs.11703] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Affiliation(s)
- Sun Young Lee
- College of PharmacyKyung Hee University Seoul 02447 Republic of Korea
| | - Kwonseong Kim
- Department of ChemistrySogang University Seoul 04107 Republic of Korea
| | - Hyun Soo Kwon
- School of Earth Science and Environment EngineeringGwangju Institute of Science and Technology Gwangju 61005 Republic of Korea
| | - Young Eun Kim
- Therapeutics & Biotechnology DivisionKorea Research Institute of Chemical Technology Daejeon 305‐600 Republic of Korea
| | - Ki Young Kim
- Therapeutics & Biotechnology DivisionKorea Research Institute of Chemical Technology Daejeon 305‐600 Republic of Korea
| | - Ji‐Seon Jeong
- Center for Bioanalysis, Division of Chemical and Medical MetrologyKorea Research Institute of Standards and Science Daejeon 34113 Republic of Korea
| | - Han Bin Oh
- Department of ChemistrySogang University Seoul 04107 Republic of Korea
| | - Tae Young Kim
- School of Earth Science and Environment EngineeringGwangju Institute of Science and Technology Gwangju 61005 Republic of Korea
| | - Jongki Hong
- College of PharmacyKyung Hee University Seoul 02447 Republic of Korea
| | - Dukjin Kang
- Center for Bioanalysis, Division of Chemical and Medical MetrologyKorea Research Institute of Standards and Science Daejeon 34113 Republic of Korea
| |
Collapse
|
7
|
Fast LC-MS quantitation of glucose and glycerol via enzymatic derivatization. Anal Biochem 2019; 575:40-43. [PMID: 30940446 DOI: 10.1016/j.ab.2019.03.020] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Revised: 03/26/2019] [Accepted: 03/27/2019] [Indexed: 11/21/2022]
Abstract
Glucose and glycerol are important circulating metabolites. Due to poor ionization and/or ion suppression, the liquid chromatography-mass spectrometry (LC-MS) detection of glucose and glycerol presents challenges. Here, we propose an efficient LC-MS method of quantitative glucose and glycerol detection via enzymatic derivatization to glucose-6-phosphate and sn-glycerol-3-phosphate, respectively. This derivatization protocol can be used to measure the concentrations of glucose production in a plethora of sample types for metabolic analysis and is compatible with the general metabolomics workflow. This novel approach allows us to quantitatively study glucose and glycerol metabolism using stable isotope tracers in vivo.
Collapse
|
8
|
Thacker JB, Schug KA. Use of a Continuous Stirred Tank Reactor for the Determination of Electrospray Response Factors and Its Application to Underivatized Sugars Under Various Solvent Parameters. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2019; 30:439-447. [PMID: 30560542 DOI: 10.1007/s13361-018-2112-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/22/2018] [Accepted: 11/16/2018] [Indexed: 06/09/2023]
Abstract
The relationship between the electrospray ionization (ESI)-mass spectrometric (MS) response of an analyte and its concentration has been well studied for permanently charged and basic analytes in the positive ionization mode, but there has been a lack of research effort for other analytes, and for the negative ionization mode, in general. In this study, this relationship was investigated for various adducts and deprotonated species of glucose, sucrose, and raffinose using a continuous stirred tank reactor (CSTR) coupled with ESI-tandem MS to obtain a continuum of response factors across a wide concentration range in both the positive and negative ionization modes with a single injection under 18 different combinations of solvents and additives. Profiles of response factors vs. concentrations varied widely and were dependent upon the analyte and solvent parameters. The use of ammonium trifluoroacetate resulted in the highest response factors for methanol-based and acetonitrile-based solvents in the positive and negative ionization modes, respectively. Ammonium acetate, ammonium formate, and sodium chloride in 80:20 acetonitrile:water in the negative ionization mode resulted in good linearities, useful for quantitative analysis. In the positive ionization mode, response factors tended to increase with an increase in the molecular weight of the analyte, and acetonitrile was generally found to decrease response factors. We have also demonstrated the ability of CSTR-ESI-MS to visualize ionization suppression in the presence of co-analytes. These data should be useful for liquid chromatography-ESI-MS method development for sugar analysis, to help guide the choice of mobile phase that will result in high sensitivity and linearity. Graphical Abstract.
Collapse
Affiliation(s)
- Jonathan B Thacker
- Department of Chemistry and Biochemistry, The University of Texas at Arlington, 700 Planetarium Pl., Box 19065, Arlington, TX, 76019-0065, USA
| | - Kevin A Schug
- Department of Chemistry and Biochemistry, The University of Texas at Arlington, 700 Planetarium Pl., Box 19065, Arlington, TX, 76019-0065, USA.
| |
Collapse
|
9
|
Khamis MM, Adamko DJ, Purves RW, El-Aneed A. Quantitative determination of potential urine biomarkers of respiratory illnesses using new targeted metabolomic approach. Anal Chim Acta 2018; 1047:81-92. [PMID: 30567667 DOI: 10.1016/j.aca.2018.09.035] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2018] [Revised: 09/12/2018] [Accepted: 09/16/2018] [Indexed: 11/16/2022]
Abstract
The diagnosis of asthma and chronic obstructive pulmonary disease (COPD) can be challenging due to the overlap in their clinical presentations in some patients. There is a need for a more objective clinical test that can be routinely used in primary care settings. Through an untargeted 1H NMR urine metabolomic approach, we identified a set of endogenous metabolites as potential biomarkers for the differentiation of asthma and COPD. A subset of these potential biomarkers contains 7 highly polar metabolites of diverse physicochemical properties. To the best of our knowledge, there is no liquid chromatography-tandem mass spectrometry (LC-MS/MS) method that evaluated more than two of the target metabolites in a single analytical run. The target metabolites belong to the families of monosaccharides, organic acids, amino acids, quaternary ammonium compounds and nucleic acids, rendering hydrophilic interaction liquid chromatography (HILIC) an ideal technology for their quantification. Since a clinical decision is to be made from patients data, a fully validated analytical method is required for biomarker validation. Method validation for endogenous metabolites is a daunting task since current guidelines were designed for exogenous compounds. As such, innovative approaches were adopted to meet the validation requirements. Herein, we describe a sensitive HILIC-MS/MS method for the quantification of the 7 endogenous urinary metabolites. Detection was achieved in the multiple reaction monitoring (MRM) mode with polarity switching, using quadrupole-linear ion trap instrument (QTRAP 6500) as well as single ion monitoring in the negative-ion mode. The method was fully validated according to the regulatory guidelines. Linearity was established between 6 and 21000 ng/mL and quality control samples demonstrated acceptable intra- and inter-day accuracy (85.7%-112%), intra- and inter-day precision (CV% <11.5%) as well as stability under various storage and sample processing conditions. To illustrate the method's applicability, the validated method was applied to the analysis of a small set of urine samples collected from asthma and COPD patients. Preliminary modelling of separation was generated using partial least square discriminant analysis (R2 0.752 and Q2 0.57). The adequate separation between patient samples confirms the diagnostic potential of these target metabolites as a proof-of-concept for the differentiation between asthma and COPD. However, more patient urine samples are needed in order to increase the statistical power of the analytical model.
Collapse
Affiliation(s)
- Mona M Khamis
- College of Pharmacy and Nutrition, University of Saskatchewan, Saskatoon, SK, Canada
| | - Darryl J Adamko
- Department of Pediatrics, College of Medicine, University of Saskatchewan, Saskatoon, SK, Canada
| | - Randy W Purves
- Canadian Food Inspection Agency (CFIA), Saskatoon, SK, Canada
| | - Anas El-Aneed
- College of Pharmacy and Nutrition, University of Saskatchewan, Saskatoon, SK, Canada.
| |
Collapse
|
10
|
Huang YL, Jhou BY, Chen SF, Khoo KH. Identifying Specific and Differentially Linked Glycosyl Residues in Mammalian Glycans by Targeted LC-MS Analysis. ANAL SCI 2018; 34:1049-1054. [PMID: 30146545 DOI: 10.2116/analsci.18scp01] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Glycans, which are widespread in nature, consist of a large number of monosaccharides linked via glycosidic bonds. Due to the complex nature of glycan structures on glycoproteins, assessing the configuration and positions of the glycosidic linkages of a glycan is a subject of considerable interest. In this study, a method for accomplishing this using partially O-methylated alditols (PMAs) from glycans combined with LC-MS analysis is reported. N-Glycans were first per-methylated with methyl iodide, and the levels of methylation were further confirmed by MALDI-TOF. PMAs were then produced via complete hydrolysis and reduction. PMAs derived from Fetuin N-glycan and Lewisa antigen carbohydrates were successfully detected by LC-MS analysis. This analysis can be performed without the need for an additional derivatization step for GC analysis, and should be suitable for use in conjunction with a LC-MS-based analysis platform.
Collapse
Affiliation(s)
- Yi-Li Huang
- Department of Chemistry, National Taiwan Normal University
| | - Bing-Yi Jhou
- Department of Chemistry, National Taiwan Normal University
| | - Sung-Fang Chen
- Department of Chemistry, National Taiwan Normal University
| | | |
Collapse
|
11
|
Monitoring glucose, calcium, and magnesium levels in saliva as a non-invasive analysis by sequential injection multi-parametric determination. Talanta 2018; 186:192-199. [DOI: 10.1016/j.talanta.2018.04.055] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Revised: 03/30/2018] [Accepted: 04/19/2018] [Indexed: 11/22/2022]
|
12
|
Yu L, Wen C, Li X, Fang S, Yang L, Wang T, Hu K. Simultaneous quantification of endogenous and exogenous plasma glucose by isotope dilution LC-MS/MS with indirect MRM of the derivative tag. Anal Bioanal Chem 2018; 410:2011-2018. [DOI: 10.1007/s00216-018-0872-6] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2017] [Revised: 12/23/2017] [Accepted: 01/11/2018] [Indexed: 11/29/2022]
|
13
|
Wang Q, Yu L, Qi CB, Ding J, He XM, Wang RQ, Feng YQ. Rapid and sensitive serum glucose determination using chemical labeling coupled with black phosphorus-assisted laser desorption/ionization time-of-flight mass spectrometry. Talanta 2018; 176:344-349. [DOI: 10.1016/j.talanta.2017.08.055] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2017] [Revised: 08/11/2017] [Accepted: 08/15/2017] [Indexed: 11/16/2022]
|
14
|
Trötzmüller M, Triebl A, Ajsic A, Hartler J, Köfeler H, Regittnig W. Determination of the Isotopic Enrichment of 13C- and 2H-Labeled Tracers of Glucose Using High-Resolution Mass Spectrometry: Application to Dual- and Triple-Tracer Studies. Anal Chem 2017; 89:12252-12260. [DOI: 10.1021/acs.analchem.7b03134] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Affiliation(s)
- Martin Trötzmüller
- Omics Center Graz, BioTechMed-Graz, Stiftingtalstrasse
24, 8010 Graz, Austria
| | | | | | - Jürgen Hartler
- Omics Center Graz, BioTechMed-Graz, Stiftingtalstrasse
24, 8010 Graz, Austria
- Institute of Computational
Biotechnology, Graz University of Technology, Petersgasse 14, A-8010 Graz, Austria
| | - Harald Köfeler
- Omics Center Graz, BioTechMed-Graz, Stiftingtalstrasse
24, 8010 Graz, Austria
| | | |
Collapse
|
15
|
Shields PG, Berman M, Brasky TM, Freudenheim JL, Mathe E, McElroy JP, Song MA, Wewers MD. A Review of Pulmonary Toxicity of Electronic Cigarettes in the Context of Smoking: A Focus on Inflammation. Cancer Epidemiol Biomarkers Prev 2017; 26:1175-1191. [PMID: 28642230 PMCID: PMC5614602 DOI: 10.1158/1055-9965.epi-17-0358] [Citation(s) in RCA: 85] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2017] [Revised: 05/22/2017] [Accepted: 05/24/2017] [Indexed: 12/30/2022] Open
Abstract
The use of electronic cigarettes (e-cigs) is increasing rapidly, but their effects on lung toxicity are largely unknown. Smoking is a well-established cause of lung cancer and respiratory disease, in part through inflammation. It is plausible that e-cig use might affect similar inflammatory pathways. E-cigs are used by some smokers as an aid for quitting or smoking reduction, and by never smokers (e.g., adolescents and young adults). The relative effects for impacting disease risk may differ for these groups. Cell culture and experimental animal data indicate that e-cigs have the potential for inducing inflammation, albeit much less than smoking. Human studies show that e-cig use in smokers is associated with substantial reductions in blood or urinary biomarkers of tobacco toxicants when completely switching and somewhat for dual use. However, the extent to which these biomarkers are surrogates for potential lung toxicity remains unclear. The FDA now has regulatory authority over e-cigs and can regulate product and e-liquid design features, such as nicotine content and delivery, voltage, e-liquid formulations, and flavors. All of these factors may impact pulmonary toxicity. This review summarizes current data on pulmonary inflammation related to both smoking and e-cig use, with a focus on human lung biomarkers. Cancer Epidemiol Biomarkers Prev; 26(8); 1175-91. ©2017 AACR.
Collapse
Affiliation(s)
- Peter G Shields
- Comprehensive Cancer Center, The Ohio State University and James Cancer Hospital, and College of Medicine, Columbus, Ohio.
| | - Micah Berman
- Comprehensive Cancer Center, The Ohio State University and James Cancer Hospital, and College of Public Health, Ohio
| | - Theodore M Brasky
- Comprehensive Cancer Center, The Ohio State University and James Cancer Hospital, and College of Medicine, Columbus, Ohio
| | - Jo L Freudenheim
- Department of Epidemiology and Environmental Health, School of Public Health and Health Professions, University at Buffalo, Buffalo, New York
| | - Ewy Mathe
- Department of Biomedical Informatics, The Ohio State University, Columbus, Ohio
| | - Joseph P McElroy
- Center for Biostatistics, Department of Biomedical Informatics, The Ohio State University, Columbus, Ohio
| | - Min-Ae Song
- Comprehensive Cancer Center, The Ohio State University and James Cancer Hospital, and College of Medicine, Columbus, Ohio
| | - Mark D Wewers
- Department of Internal Medicine, The Ohio State University, Columbus, Ohio
| |
Collapse
|
16
|
Arts M, Soons Z, Ellis SR, Pierzchalski KA, Balluff B, Eijkel GB, Dubois LJ, Lieuwes NG, Agten SM, Hackeng TM, van Loon LJC, Heeren RMA, Olde Damink SWM. Detection of Localized Hepatocellular Amino Acid Kinetics by using Mass Spectrometry Imaging of Stable Isotopes. Angew Chem Int Ed Engl 2017. [DOI: 10.1002/ange.201702669] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Martijn Arts
- Department of General Surgery (NUTRIM); Maastricht University; Postbus 616 6200 MD Maastricht The Netherlands
| | - Zita Soons
- Department of General Surgery (NUTRIM); Maastricht University; Postbus 616 6200 MD Maastricht The Netherlands
| | - Shane R. Ellis
- Maastricht MultiModal Imaging Institute (M4I); Division of Imaging Mass Spectrometry; Maastricht University; Postbus 616 6200 MD Maastricht The Netherlands
| | - Keely A. Pierzchalski
- Maastricht MultiModal Imaging Institute (M4I); Division of Imaging Mass Spectrometry; Maastricht University; Postbus 616 6200 MD Maastricht The Netherlands
| | - Benjamin Balluff
- Maastricht MultiModal Imaging Institute (M4I); Division of Imaging Mass Spectrometry; Maastricht University; Postbus 616 6200 MD Maastricht The Netherlands
| | - Gert B. Eijkel
- Maastricht MultiModal Imaging Institute (M4I); Division of Imaging Mass Spectrometry; Maastricht University; Postbus 616 6200 MD Maastricht The Netherlands
| | - Ludwig J. Dubois
- Department of Radiation Oncology (MAASTRO, GROW); Maastricht University; Postbus 616 6200 MD Maastricht The Netherlands
| | - Natasja G. Lieuwes
- Department of Radiation Oncology (MAASTRO, GROW); Maastricht University; Postbus 616 6200 MD Maastricht The Netherlands
| | - Stijn M. Agten
- Department of Biochemistry (CARIM); Maastricht University; Postbus 616 6200 MD Maastricht The Netherlands
| | - Tilman M. Hackeng
- Department of Biochemistry (CARIM); Maastricht University; Postbus 616 6200 MD Maastricht The Netherlands
| | - Luc J. C. van Loon
- Department of Human Biology and Movement Sciences (NUTRIM); Maastricht University; Postbus 616 6200 MD Maastricht The Netherlands
| | - Ron M. A. Heeren
- Maastricht MultiModal Imaging Institute (M4I); Division of Imaging Mass Spectrometry; Maastricht University; Postbus 616 6200 MD Maastricht The Netherlands
| | - Steven W. M. Olde Damink
- Department of General Surgery (NUTRIM); Maastricht University; Postbus 616 6200 MD Maastricht The Netherlands
- Department of General, Visceral and Transplantation Surgery; University Hospital RWTH Aachen; 52075 Aachen Germany
| |
Collapse
|
17
|
Arts M, Soons Z, Ellis SR, Pierzchalski KA, Balluff B, Eijkel GB, Dubois LJ, Lieuwes NG, Agten SM, Hackeng TM, van Loon LJC, Heeren RMA, Olde Damink SWM. Detection of Localized Hepatocellular Amino Acid Kinetics by using Mass Spectrometry Imaging of Stable Isotopes. Angew Chem Int Ed Engl 2017; 56:7146-7150. [PMID: 28493648 PMCID: PMC6099435 DOI: 10.1002/anie.201702669] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/14/2017] [Revised: 04/21/2017] [Indexed: 11/09/2022]
Abstract
Mass spectrometry imaging (MSI) simultaneously detects and identifies the spatial distribution of numerous molecules throughout tissues. Currently, MSI is limited to providing a static and ex vivo snapshot of highly dynamic systems in which molecules are constantly synthesized and consumed. Herein, we demonstrate an innovative MSI methodology to study dynamic molecular changes of amino acids within biological tissues by measuring the dilution and conversion of stable isotopes in a mouse model. We evaluate the method specifically on hepatocellular metabolism of the essential amino acid l-phenylalanine, associated with liver diseases. Crucially, the method reveals the localized dynamics of l-phenylalanine metabolism, including its in vivo hydroxylation to l-tyrosine and co-localization with other liver metabolites in a time course of samples from different animals. This method thus enables the dynamics of localized biochemical synthesis to be studied directly from biological tissues.
Collapse
Affiliation(s)
- Martijn Arts
- Department of General Surgery (NUTRIM), Maastricht University, Postbus 616, 6200 MD, Maastricht, The Netherlands
| | - Zita Soons
- Department of General Surgery (NUTRIM), Maastricht University, Postbus 616, 6200 MD, Maastricht, The Netherlands
| | - Shane R Ellis
- Maastricht MultiModal Imaging Institute (M4I), Division of Imaging Mass Spectrometry, Maastricht University, Postbus 616, 6200 MD, Maastricht, The Netherlands
| | - Keely A Pierzchalski
- Maastricht MultiModal Imaging Institute (M4I), Division of Imaging Mass Spectrometry, Maastricht University, Postbus 616, 6200 MD, Maastricht, The Netherlands
| | - Benjamin Balluff
- Maastricht MultiModal Imaging Institute (M4I), Division of Imaging Mass Spectrometry, Maastricht University, Postbus 616, 6200 MD, Maastricht, The Netherlands
| | - Gert B Eijkel
- Maastricht MultiModal Imaging Institute (M4I), Division of Imaging Mass Spectrometry, Maastricht University, Postbus 616, 6200 MD, Maastricht, The Netherlands
| | - Ludwig J Dubois
- Department of Radiation Oncology (MAASTRO, GROW), Maastricht University, Postbus 616, 6200 MD, Maastricht, The Netherlands
| | - Natasja G Lieuwes
- Department of Radiation Oncology (MAASTRO, GROW), Maastricht University, Postbus 616, 6200 MD, Maastricht, The Netherlands
| | - Stijn M Agten
- Department of Biochemistry (CARIM), Maastricht University, Postbus 616, 6200 MD, Maastricht, The Netherlands
| | - Tilman M Hackeng
- Department of Biochemistry (CARIM), Maastricht University, Postbus 616, 6200 MD, Maastricht, The Netherlands
| | - Luc J C van Loon
- Department of Human Biology and Movement Sciences (NUTRIM), Maastricht University, Postbus 616, 6200 MD, Maastricht, The Netherlands
| | - Ron M A Heeren
- Maastricht MultiModal Imaging Institute (M4I), Division of Imaging Mass Spectrometry, Maastricht University, Postbus 616, 6200 MD, Maastricht, The Netherlands
| | - Steven W M Olde Damink
- Department of General Surgery (NUTRIM), Maastricht University, Postbus 616, 6200 MD, Maastricht, The Netherlands.,Department of General, Visceral and Transplantation Surgery, University Hospital RWTH Aachen, 52075, Aachen, Germany
| |
Collapse
|
18
|
Nakamura M, Iso H, Kitamura A, Imano H, Noda H, Kiyama M, Sato S, Yamagishi K, Nishimura K, Nakai M, Vesper HW, Teramoto T, Miyamoto Y. Comparison between the triglycerides standardization of routine methods used in Japan and the chromotropic acid reference measurement procedure used by the CDC Lipid Standardization Programme. Ann Clin Biochem 2016; 53:632-639. [PMID: 26680645 DOI: 10.1177/0004563215624461] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background The US Centers for Disease Control and Prevention ensured adequate performance of the routine triglycerides methods used in Japan by a chromotropic acid reference measurement procedure used by the Centers for Disease Control and Prevention lipid standardization programme as a reference point. We examined standardized data to clarify the performance of routine triglycerides methods. Methods The two routine triglycerides methods were the fluorometric method of Kessler and Lederer and the enzymatic method. The methods were standardized using 495 Centers for Disease Control and Prevention reference pools with 98 different concentrations ranging between 0.37 and 5.15 mmol/L in 141 survey runs. The triglycerides criteria for laboratories which perform triglycerides analyses are used: accuracy, as bias ≤5% from the Centers for Disease Control and Prevention reference value and precision, as measured by CV, ≤5%. Results The correlation of the bias of both methods to the Centers for Disease Control and Prevention reference method was: y (%bias) = 0.516 × (Centers for Disease Control and Prevention reference value) -1.292 ( n = 495, R2 = 0.018). Triglycerides bias at medical decision points of 1.13, 1.69 and 2.26 mmol/L was -0.71%, -0.42% and -0.13%, respectively. For the combined precision, the equation y (CV) = -0.398 × (triglycerides value) + 1.797 ( n = 495, R2 = 0.081) was used. Precision was 1.35%, 1.12% and 0.90%, respectively. It was shown that triglycerides measurements at Osaka were stable for 36 years. Conclusions The epidemiologic laboratory in Japan met acceptable accuracy goals for 88.7% of all samples, and met acceptable precision goals for 97.8% of all samples measured through the Centers for Disease Control and Prevention lipid standardization programme and demonstrated stable results for an extended period of time.
Collapse
Affiliation(s)
- Masakazu Nakamura
- 1 Lipid Reference Laboratory, Department of Preventive Cardiology, National Cerebral and Cardiovascular Center, Osaka, Japan
| | - Hiroyasu Iso
- 2 Public Health, Department of Social Medicine, Graduate School of Medicine, Osaka University, Osaka, Japan
| | - Akihiko Kitamura
- 2 Public Health, Department of Social Medicine, Graduate School of Medicine, Osaka University, Osaka, Japan
| | - Hironori Imano
- 2 Public Health, Department of Social Medicine, Graduate School of Medicine, Osaka University, Osaka, Japan
| | - Hiroyuki Noda
- 2 Public Health, Department of Social Medicine, Graduate School of Medicine, Osaka University, Osaka, Japan
| | - Masahiko Kiyama
- 3 Osaka Center for Cancer and Cardiovascular Disease Prevention, Osaka, Japan
| | - Shinichi Sato
- 4 Chiba Prefectural Institute of Public Health/Osaka Prefecture University, Institution of Public Nutrition Practice, Chiba, Japan
| | - Kazumasa Yamagishi
- 5 Department of Public Health Medicine, Faculty of Medicine, University of Tsukuba, Ibaraki, Japan
| | - Kunihiro Nishimura
- 6 Department of Statistics and Data Analysis, Center for Cerebral and Cardiovascular Disease Information, National Cerebral and Cardiovascular Center, Osaka, Japan
| | - Michikazu Nakai
- 6 Department of Statistics and Data Analysis, Center for Cerebral and Cardiovascular Disease Information, National Cerebral and Cardiovascular Center, Osaka, Japan
| | - Hubert W Vesper
- 7 Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA, USA
| | - Tamio Teramoto
- 8 Teikyo Academic Research Center, Teikyo University, Tokyo, Japan
| | - Yoshihiro Miyamoto
- 9 Department of Preventive Cardiology, National Cerebral and Cardiovascular Center, Osaka, Japan
| |
Collapse
|
19
|
Deventer K, Van Eenoo P. Screening and confirmation of a glycerol-positive case. Drug Test Anal 2016; 7:1009-13. [PMID: 26695488 DOI: 10.1002/dta.1913] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2015] [Revised: 09/28/2015] [Accepted: 10/01/2015] [Indexed: 11/09/2022]
Affiliation(s)
- Koen Deventer
- Doping Control Laboratory (DoCoLab), Department of Clinical Chemistry, Microbiology and Immunology, Ghent University (UGent), Technologiepark 30, B-9052, Zwijnaarde, Belgium
| | - Peter Van Eenoo
- Doping Control Laboratory (DoCoLab), Department of Clinical Chemistry, Microbiology and Immunology, Ghent University (UGent), Technologiepark 30, B-9052, Zwijnaarde, Belgium
| |
Collapse
|
20
|
Concord and Niagara Grape Juice and Their Phenolics Modify Intestinal Glucose Transport in a Coupled in Vitro Digestion/Caco-2 Human Intestinal Model. Nutrients 2016; 8:nu8070414. [PMID: 27399765 PMCID: PMC4963890 DOI: 10.3390/nu8070414] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2016] [Revised: 05/18/2016] [Accepted: 06/30/2016] [Indexed: 01/23/2023] Open
Abstract
While the potential of dietary phenolics to mitigate glycemic response has been proposed, the translation of these effects to phenolic rich foods such as 100% grape juice (GJ) remains unclear. Initial in vitro screening of GJ phenolic extracts from American grape varieties (V. labrusca; Niagara and Concord) suggested limited inhibitory capacity for amylase and α-glucosidase (6.2%-11.5% inhibition; p < 0.05). Separately, all GJ extracts (10-100 µM total phenolics) did reduce intestinal trans-epithelial transport of deuterated glucose (d7-glu) and fructose (d7-fru) by Caco-2 monolayers in a dose-dependent fashion, with 60 min d7-glu/d7-fru transport reduced 10%-38% by GJ extracts compared to control. To expand on these findings by assessing the ability of 100% GJ to modify starch digestion and glucose transport from a model starch-rich meal, 100% Niagara and Concord GJ samples were combined with a starch rich model meal (1:1 and 1:2 wt:wt) and glucose release and transport were assessed in a coupled in vitro digestion/Caco-2 cell model. Digestive release of glucose from the starch model meal was decreased when digested in the presence of GJs (5.9%-15% relative to sugar matched control). Furthermore, transport of d7-glu was reduced 10%-38% by digesta containing bioaccessible phenolics from Concord and Niagara GJ compared to control. These data suggest that phenolics present in 100% GJ may alter absorption of monosaccharides naturally present in 100% GJ and may potentially alter glycemic response if consumed with a starch rich meal.
Collapse
|
21
|
Sensing of Salivary Glucose Using Nano-Structured Biosensors. BIOSENSORS-BASEL 2016; 6:bios6010010. [PMID: 26999233 PMCID: PMC4810402 DOI: 10.3390/bios6010010] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/12/2016] [Revised: 03/05/2016] [Accepted: 03/14/2016] [Indexed: 11/22/2022]
Abstract
The anxiety and pain associated with frequent finger pricking has always been troublesome for diabetics measuring blood glucose (BG) in their daily lives. For this reason, a reliable glucose monitoring system that allows noninvasive measurements is highly desirable. Our main objective is to develop a biosensor that can detect low-level glucose in saliva (physiological range 0.5–20 mg/dL). Salivary glucose (SG) sensors were built using a layer-by-layer self-assembly of single-walled carbon nanotubes, chitosan, gold nanoparticles, and glucose oxidase onto a screen-printed platinum electrode. An electrochemical method was utilized for the quantitative detection of glucose in both buffer solution and saliva samples. A standard spectrophotometric technique was used as a reference method to validate the glucose content of each sample. The disposable glucose sensors have a detection limit of 0.41 mg/dL, a sensitivity of 0.24 μA·s·dL·mg−1, a linear range of 0.5–20 mg/dL in buffer solution, and a response time of 30 s. A study of 10 healthy subjects was conducted, and SG levels between 1.1 to 10.1 mg/dL were successfully detected. The results revealed that the noninvasive SG monitoring could be an alternative for diabetes self-management at home. This paper is not intended to replace regular BG tests, but to study SG itself as an indicator for the quality of diabetes care. It can potentially help patients control and monitor their health conditions, enabling them to comply with prescribed treatments for diabetes.
Collapse
|
22
|
O'Neill H, Shah R, Evans BR, He J, Pingali SV, Chundawat SPS, Jones AD, Langan P, Davison BH, Urban V. Production of bacterial cellulose with controlled deuterium-hydrogen substitution for neutron scattering studies. Methods Enzymol 2015; 565:123-46. [PMID: 26577730 DOI: 10.1016/bs.mie.2015.08.031] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Isotopic enrichment of biomacromolecules is a widely used technique that enables the investigation of the structural and dynamic properties to provide information not accessible with natural abundance isotopic composition. This study reports an approach for deuterium incorporation into bacterial cellulose. A media formulation for growth of Acetobacter xylinus subsp. sucrofermentans and Gluconacetobacter hansenii was formulated that supports cellulose production in deuterium (D) oxide. The level of D incorporation can be varied by altering the ratio of deuterated and protiated glycerol used during cell growth in the D2O-based growth medium. Spectroscopic analysis and mass spectrometry show that the level of deuterium incorporation is high (>90%) for the perdeuterated form of bacterial cellulose. The small-angle neutron scattering profiles of the cellulose with different amounts of D incorporation are all similar indicating that there are no structural changes in the cellulose due to substitution of deuterium for hydrogen. In addition, by varying the amount of deuterated glycerol in the media it was possible to vary the scattering length density of the deuterated cellulose. The ability to control deuterium content of cellulose extends the range of experiments using techniques such as neutron scattering to reveal information about the structure and dynamics of cellulose, and its interactions with other biomacromolecules as well as synthetic polymers used for development of composite materials.
Collapse
Affiliation(s)
- Hugh O'Neill
- Biology and Soft Matter Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee, USA.
| | - Riddhi Shah
- Biology and Soft Matter Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee, USA; Bredesen Center for Interdisciplinary Research and Graduate Education, University of Tennessee, Knoxville, Tennessee, USA
| | - Barbara R Evans
- Chemical Sciences Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee, USA
| | - Junhong He
- Biology and Soft Matter Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee, USA
| | - Sai Venkatesh Pingali
- Biology and Soft Matter Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee, USA
| | - Shishir P S Chundawat
- Department of Chemical and Biochemical Engineering, Rutgers University, Piscataway, New Jersey, USA
| | - A Daniel Jones
- Department of Biochemistry and Molecular Biology, Michigan State University, East Lansing, Michigan, USA; Department of Chemistry, Michigan State University, East Lansing, Michigan, USA
| | - Paul Langan
- Biology and Soft Matter Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee, USA
| | - Brian H Davison
- Biosciences Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee, USA
| | - Volker Urban
- Biology and Soft Matter Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee, USA
| |
Collapse
|
23
|
Tsao CW, Yang ZJ. High Sensitivity and High Detection Specificity of Gold-Nanoparticle-Grafted Nanostructured Silicon Mass Spectrometry for Glucose Analysis. ACS APPLIED MATERIALS & INTERFACES 2015; 7:22630-22637. [PMID: 26393877 DOI: 10.1021/acsami.5b07395] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Desorption/ionization on silicon (DIOS) is a high-performance matrix-free mass spectrometry (MS) analysis method that involves using silicon nanostructures as a matrix for MS desorption/ionization. In this study, gold nanoparticles grafted onto a nanostructured silicon (AuNPs-nSi) surface were demonstrated as a DIOS-MS analysis approach with high sensitivity and high detection specificity for glucose detection. A glucose sample deposited on the AuNPs-nSi surface was directly catalyzed to negatively charged gluconic acid molecules on a single AuNPs-nSi chip for MS analysis. The AuNPs-nSi surface was fabricated using two electroless deposition steps and one electroless etching step. The effects of the electroless fabrication parameters on the glucose detection efficiency were evaluated. Practical application of AuNPs-nSi MS glucose analysis in urine samples was also demonstrated in this study.
Collapse
Affiliation(s)
- Chia-Wen Tsao
- Department of Mechanical Engineering, National Central University , Taoyuan City 32001, Taiwan
| | - Zhi-Jie Yang
- Department of Mechanical Engineering, National Central University , Taoyuan City 32001, Taiwan
| |
Collapse
|
24
|
Simultaneous quantification of labeled (2)H5-glycerol, (13)C6-glucose, and endogenous D-glucose in mouse plasma using liquid chromatography tandem mass spectrometry. Anal Bioanal Chem 2015; 407:8617-22. [PMID: 26362155 DOI: 10.1007/s00216-015-9015-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2015] [Revised: 08/07/2015] [Accepted: 08/27/2015] [Indexed: 10/23/2022]
Abstract
Monitoring the level of glucose and glycerol or their labeled derivatives in biological fluid for kinetic studies has always been challenging, especially in mice, because of the limited volume in addition to the complexity of plasma. For such application, we developed a simple, fast, and sensitive method for the simultaneous measurement of absolute concentrations of labeled (2)H5-glycerol and (13)C6-glucose as well as endogenous D-glucose using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). In our study, 15.0 μL of mouse plasma was processed by a one-step protein precipitation, followed by LC-MS/MS analysis. The quantification of the analytes was carried out by monitoring the product ion scan of their corresponding deprotonated molecular ions and constructing the extracted ion fragmentogram by choosing a specific product ion for each analyte (equivalent to precursor ion to product ion transitions). The limit of detection (LOD) was evaluated to be 1.0 μM for both (2)H5-glycerol and (13)C6-glucose, and the limit of quantitation (LOQ) was observed to be 5.0 μM for both (2)H5-glycerol and (13)C6-glucose in diluted mice plasma that corresponds to 50 μM in plasma or 4.60 and 9.01 mg/dL of glycerol and glucose in plasma, respectively. The extraction recoveries are 81.9 % (CV = 8.1 %) for (2)H5-glycerol and 26.2 % (CV = 13.6 %) for (13)C6-glucose.
Collapse
|
25
|
Chen Y, Teo HL, Liu Q, Lee TK. Developing a reference measurement procedure for free glycerol in human serum by two-step gas chromatography–isotope dilution mass spectrometry. Clin Biochem 2015; 48:897-903. [DOI: 10.1016/j.clinbiochem.2015.05.022] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2015] [Revised: 05/25/2015] [Accepted: 05/29/2015] [Indexed: 11/26/2022]
|
26
|
Mechri B, Tekaya M, Cheheb H, Hammami M. Determination of Mannitol Sorbitol and Myo-Inositol in Olive Tree Roots and Rhizospheric Soil by Gas Chromatography and Effect of Severe Drought Conditions on Their Profiles. J Chromatogr Sci 2015; 53:1631-8. [DOI: 10.1093/chromsci/bmv066] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2014] [Indexed: 11/13/2022]
|
27
|
Matsunami RK, Angelides K, Engler DA. Development and Validation of a Rapid (13)C6-Glucose Isotope Dilution UPLC-MRM Mass Spectrometry Method for Use in Determining System Accuracy and Performance of Blood Glucose Monitoring Devices. J Diabetes Sci Technol 2015; 9:1051-60. [PMID: 25986627 PMCID: PMC4667352 DOI: 10.1177/1932296815586015] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND There is currently considerable discussion about the accuracy of blood glucose concentrations determined by personal blood glucose monitoring systems (BGMS). To date, the FDA has allowed new BGMS to demonstrate accuracy in reference to other glucose measurement systems that use the same or similar enzymatic-based methods to determine glucose concentration. These types of reference measurement procedures are only comparative in nature and are subject to the same potential sources of error in measurement and system perturbations as the device under evaluation. It would be ideal to have a completely orthogonal primary method that could serve as a true standard reference measurement procedure for establishing the accuracy of new BGMS. METHODS An isotope-dilution liquid chromatography/mass spectrometry (ID-UPLC-MRM) assay was developed using (13)C6-glucose as a stable isotope analogue to specifically measure glucose concentration in human plasma, and validated for use against NIST standard reference materials, and against fresh isolates of whole blood and plasma into which exogenous glucose had been spiked. Assay performance was quantified to NIST-traceable dry weight measures for both glucose and (13)C6-glucose. RESULTS The newly developed assay method was shown to be rapid, highly specific, sensitive, accurate, and precise for measuring plasma glucose levels. The assay displayed sufficient dynamic range and linearity to measure across the range of both normal and diabetic blood glucose levels. Assay performance was measured to within the same uncertainty levels (<1%) as the NIST definitive method for glucose measurement in human serum. CONCLUSIONS The newly developed ID UPLC-MRM assay can serve as a validated reference measurement procedure to which new BGMS can be assessed for glucose measurement performance.
Collapse
Affiliation(s)
- Risë K Matsunami
- Proteomics Programmatic Core Laboratory, Houston Methodist Hospital Research Institute, Houston, TX, USA
| | | | - David A Engler
- Proteomics Programmatic Core Laboratory, Houston Methodist Hospital Research Institute, Houston, TX, USA
| |
Collapse
|
28
|
Electrochemical biosensor based on glucose oxidase encapsulated within enzymatically synthesized poly(1,10-phenanthroline-5,6-dione). Colloids Surf B Biointerfaces 2014; 123:685-91. [DOI: 10.1016/j.colsurfb.2014.10.032] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2013] [Revised: 06/13/2014] [Accepted: 10/05/2014] [Indexed: 11/18/2022]
|
29
|
Bornø A, Foged L, van Hall G. Glucose and glycerol concentrations and their tracer enrichment measurements using liquid chromatography tandem mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2014; 49:980-988. [PMID: 25303387 DOI: 10.1002/jms.3407] [Citation(s) in RCA: 40] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2014] [Revised: 05/26/2014] [Accepted: 06/01/2014] [Indexed: 06/04/2023]
Abstract
The present study describes a new liquid chromatography tandem mass spectrometry method for high-throughput quantification of glucose and glycerol in human plasma using stable isotopically labeled internal standards and is suitable for simultaneous measurements of glucose and glycerol enrichments in connection to in vivo metabolic studies investigating glucose turnover and lipolytic rate. Moreover, in order to keep up with this new fast analysis, simple derivatization procedures have been developed. Prior to analysis, glucose and glycerol were derivatized using benzoyl chloride in order to form benzoylated derivatives via new simplified fast procedures. For glucose, two internal standards were evaluated, [U-(13) C(6)]glucose and [U-(13) C(6), D(7)]glucose, and for glycerol, [U-(13) C(3), D(8)]glycerol was used. The method was validated by means of calibration curves, quality control samples, and plasma samples spiked with [6,6-D(2)]glucose, [U-(13) C(6)]glucose, and [1,1,2,3,3-D(5)]glycerol in order to test accuracy, precision, and recovery of the method. Moreover, post preparative and freeze-thaw sample stability were tested. The correlation of calibration curves for the glucose concentration were r(2) = 0.9998 for [U-(13) C(6)]glucose and r(2) = 0.9996 for [U-(13) C(6), D(7)]glucose, and r(2) = 0.9995 for the glycerol concentration. Interday accuracy for glucose using [U-(13) C(6)]glucose and glycerol determined in spiked plasma were respectively 103.5% and 106.0%, and the coefficients of variation were 2.0% and 9.7%, respectively. After derivatization, plasma samples were stable for at least 14 days. In conclusion, we have developed and validated a novel, accurate, and sensitive high-throughput liquid chromatography tandem mass spectrometry method for simultaneous determination of glucose and glycerol concentrations and enrichment of infused tracers most commonly used in human metabolic kinetic studies.
Collapse
Affiliation(s)
- Andreas Bornø
- Clinical Metabolomics Core Facility (CMCF), Rigshospitalet, section 7652, Ole Maaløesvej 26, 2100, Copenhagen Ø, Denmark
| | | | | |
Collapse
|
30
|
Dong Y, Ma Y, Yan K, Shen L, Wang X, Xu Y, He G, Wu Y, Lu J, Yang Z, Feng F. Quantitative analysis of glycerol levels in human urine by liquid chromatography–tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2014; 957:30-5. [DOI: 10.1016/j.jchromb.2014.02.054] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2013] [Revised: 02/12/2014] [Accepted: 02/16/2014] [Indexed: 10/25/2022]
|
31
|
Shen Y, Xu Z. An improved GC–MS method in determining glycerol in different types of biological samples. J Chromatogr B Analyt Technol Biomed Life Sci 2013; 930:36-40. [DOI: 10.1016/j.jchromb.2013.04.034] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2013] [Revised: 04/23/2013] [Accepted: 04/24/2013] [Indexed: 11/28/2022]
|
32
|
Lee HS, Lee JM, Park SR, Lee JH, Kim YG. Development and Validation of Primary Method for the Determination of Glucose in Human Serum by Isotope Dilution Liquid Chromatography Tandem Mass Spectrometry and Comparison with Field Methods. B KOREAN CHEM SOC 2013. [DOI: 10.5012/bkcs.2013.34.6.1698] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
33
|
Previs SF, McLaren DG, Wang SP, Stout SJ, Zhou H, Herath K, Shah V, Miller PL, Wilsie L, Castro-Perez J, Johns DG, Cleary MA, Roddy TP. New methodologies for studying lipid synthesis and turnover: looking backwards to enable moving forwards. Biochim Biophys Acta Mol Basis Dis 2013; 1842:402-13. [PMID: 23707557 DOI: 10.1016/j.bbadis.2013.05.019] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2013] [Revised: 05/11/2013] [Accepted: 05/13/2013] [Indexed: 12/26/2022]
Abstract
Our ability to understand the pathogenesis of problems surrounding lipid accretion requires attention towards quantifying lipid kinetics. In addition, studies of metabolic flux should also help unravel mechanisms that lead to imbalances in inter-organ lipid trafficking which contribute to dyslipidemia and/or peripheral lipid accumulation (e.g. hepatic fat deposits). This review aims to outline the development and use of novel methods for studying lipid kinetics in vivo. Although our focus is directed towards some of the approaches that are currently reported in the literature, we include a discussion of the older literature in order to put "new" methods in better perspective and inform readers of valuable historical research. Presumably, future advances in understanding lipid dynamics will benefit from a careful consideration of the past efforts, where possible we have tried to identify seminal papers or those that provide clear data to emphasize essential points. This article is part of a Special Issue entitled: Modulation of Adipose Tissue in Health and Disease.
Collapse
Affiliation(s)
- Stephen F Previs
- Molecular Biomarkers, Merck, 2015 Galloping Hill Road, Kenilworth, NJ 07033, USA.
| | - David G McLaren
- Molecular Biomarkers, Merck, 2015 Galloping Hill Road, Kenilworth, NJ 07033, USA
| | - Sheng-Ping Wang
- Molecular Biomarkers, Merck, 2015 Galloping Hill Road, Kenilworth, NJ 07033, USA
| | - Steven J Stout
- Molecular Biomarkers, Merck, 2015 Galloping Hill Road, Kenilworth, NJ 07033, USA
| | - Haihong Zhou
- Molecular Biomarkers, Merck, 2015 Galloping Hill Road, Kenilworth, NJ 07033, USA
| | - Kithsiri Herath
- Molecular Biomarkers, Merck, 2015 Galloping Hill Road, Kenilworth, NJ 07033, USA
| | - Vinit Shah
- Molecular Biomarkers, Merck, 2015 Galloping Hill Road, Kenilworth, NJ 07033, USA
| | - Paul L Miller
- Molecular Biomarkers, Merck, 2015 Galloping Hill Road, Kenilworth, NJ 07033, USA
| | - Larissa Wilsie
- Molecular Biomarkers, Merck, 2015 Galloping Hill Road, Kenilworth, NJ 07033, USA
| | - Jose Castro-Perez
- Molecular Biomarkers, Merck, 2015 Galloping Hill Road, Kenilworth, NJ 07033, USA
| | - Douglas G Johns
- Molecular Biomarkers, Merck, 2015 Galloping Hill Road, Kenilworth, NJ 07033, USA
| | - Michele A Cleary
- Molecular Biomarkers, Merck, 2015 Galloping Hill Road, Kenilworth, NJ 07033, USA
| | - Thomas P Roddy
- Molecular Biomarkers, Merck, 2015 Galloping Hill Road, Kenilworth, NJ 07033, USA
| |
Collapse
|
34
|
Nguyen DT, Yu J, Mho SI, Lee HL, Lee W, Yee ST, Lee G, Paik MJ. Method Optimization for Rapid Measurement of Carbohydrates in Plasma by Liquid Chromatography Tandem Mass Spectrometry. B KOREAN CHEM SOC 2013. [DOI: 10.5012/bkcs.2013.34.5.1571] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
35
|
Quantification of total hexose on dry blood spot by tandem mass spectrometry. Clin Biochem 2012; 45:1673-7. [PMID: 22975641 DOI: 10.1016/j.clinbiochem.2012.08.023] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2012] [Revised: 07/18/2012] [Accepted: 08/29/2012] [Indexed: 11/21/2022]
Abstract
BACKGROUND Because hypoglycemia and hyperglycemia are harmful and not always associated with overt clinical signs, it is necessary to have methods available to screen for glucose levels to detect hypoglycemia and diabetes as early as possible. A new method for such screening and the clinical determination of blood total hexose on a dry blood spot (DBS) using tandem mass spectrometry (MS/MS) was developed. METHODS The serum glucose controls and blood were prepared as DBS and then extracted into a methanol solution containing isotope-labeled internal standards. The methanolic extraction was subjected to HPLC, followed by MS/MS in positive ion mode. Multiple-reaction monitoring of m/z 203.1→23 was used to detect hexose, and m/z 209.0→23 was used for 13C6-D-glucose. RESULTS The recoveries of blood glucose by MS/MS were 90%-102% with an R(2) value of 0.999 after linear regression (p<0.001). The controls were within an acceptable range, and the coefficients of variation were less than 10%. The blood total hexose in neonates aged 3-7 days (6.41±1.46 mmol/L) was lower than that in neonates aged 8-30 days (6.66±1.38 mmol/L), and it was lower in neonates than in children aged 1-72 months (7.19±1.87 mmol/L). CONCLUSION Quantification of total hexose on a dry blood spot by MS/MS is accurate, reliable and feasible for screening and clinical tests.
Collapse
|
36
|
Russo A, Migliorini M, Cecchi L, Cherubini C, Giusti M, Zanoni B, Perri E, Nardi M, Sindona G. Identification and assay of carbohydrates in olive drupes by cesium attachment electrospray tandem mass spectrometry (ESI-MS/MS). JOURNAL OF MASS SPECTROMETRY : JMS 2012; 47:1242-1246. [PMID: 22972792 DOI: 10.1002/jms.3091] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Identification and assay of sugars in olive drupes during their ripening phase is evaluated by tandem mass spectrometry. Recent achievements have shown that the quality of an extra virgin olive oil can be directly correlated to the ripening degree of the drupes that is likely linked to their saccharides content. An innovation in this peculiar food chain is now proposed that considers a high throughput assessment of the carbohydrate content by a recently introduced protocol based on the gas-phase chemistry of sugar-cesium adducts by ESI-MS/MS.
Collapse
Affiliation(s)
- A Russo
- CRA-OLI-Centro di Ricerca per l'Olivicoltura e l'Industria Olearia, Rende, Cosenza, Italy
| | | | | | | | | | | | | | | | | |
Collapse
|
37
|
Chen Y, Liu Q, Yong S, Lee TK. High accuracy analysis of glucose in human serum by isotope dilution liquid chromatography-tandem mass spectrometry. Clin Chim Acta 2012; 413:808-13. [DOI: 10.1016/j.cca.2012.01.025] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2011] [Revised: 01/20/2012] [Accepted: 01/23/2012] [Indexed: 11/30/2022]
|
38
|
Edwards SH, Stribling SL, Pyatt SD, Kimberly MM. Reference Measurement Procedure for Total Glycerides by Isotope Dilution GC-MS. Clin Chem 2012; 58:768-76. [DOI: 10.1373/clinchem.2011.177063] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Abstract
BACKGROUND
The CDC's Lipid Standardization Program established the chromotropic acid (CA) reference measurement procedure (RMP) as the accuracy base for standardization and metrological traceability for triglyceride testing. The CA RMP has several disadvantages, including lack of ruggedness. It uses obsolete instrumentation and hazardous reagents. To overcome these problems the CDC developed an isotope dilution GC-MS (ID-GC-MS) RMP for total glycerides in serum.
METHODS
We diluted serum samples with Tris-HCl buffer solution and spiked 200-μL aliquots with [13C3]-glycerol. These samples were incubated and hydrolyzed under basic conditions. The samples were dried, derivatized with acetic anhydride and pyridine, extracted with ethyl acetate, and analyzed by ID-GC-MS. Linearity, imprecision, and accuracy were evaluated by analyzing calibrator solutions, 10 serum pools, and a standard reference material (SRM 1951b).
RESULTS
The calibration response was linear for the range of calibrator concentrations examined (0–1.24 mmol/L) with a slope and intercept of 0.717 (95% CI, 0.7123–0.7225) and 0.3122 (95% CI, 0.3096–0.3140), respectively. The limit of detection was 14.8 μmol/L. The mean %CV for the sample set (serum pools and SRM) was 1.2%. The mean %bias from NIST isotope dilution MS values for SRM 1951b was 0.7%.
CONCLUSIONS
This ID-GC-MS RMP has the specificity and ruggedness to accurately quantify total glycerides in the serum pools used in the CDC's Lipid Standardization Program and demonstrates sufficiently acceptable agreement with the NIST primary RMP for total glyceride measurement.
Collapse
Affiliation(s)
- Selvin H Edwards
- Centers for Disease Control and Prevention, National Center for Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, Atlanta, GA
| | | | - Susan D Pyatt
- Centers for Disease Control and Prevention, National Center for Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, Atlanta, GA
| | - Mary M Kimberly
- Centers for Disease Control and Prevention, National Center for Environmental Health, Division of Laboratory Sciences, Clinical Chemistry Branch, Atlanta, GA
| |
Collapse
|
39
|
Nagaraja P, Honnur Krishna, Shivakumar A, Shrestha AK. Development of quantitative enzymatic method and its validation for the assay of glucose in human serum. Clin Biochem 2012; 45:139-43. [DOI: 10.1016/j.clinbiochem.2011.11.007] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2011] [Revised: 11/13/2011] [Accepted: 11/19/2011] [Indexed: 10/14/2022]
|
40
|
Kotnik D, Šmidovnik A, Jazbec-Križman P, Križman M, Prošek M. Direct analysis of carbohydrates in animal plasma by ion chromatography coupled with mass spectrometry and pulsed amperometric detection for use as a non-invasive diagnostic tool. J Chromatogr B Analyt Technol Biomed Life Sci 2011; 879:3700-6. [DOI: 10.1016/j.jchromb.2011.10.010] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2011] [Revised: 10/04/2011] [Accepted: 10/06/2011] [Indexed: 11/25/2022]
|
41
|
van Wijck K, van Eijk HMH, Buurman WA, Dejong CHC, Lenaerts K. Novel analytical approach to a multi-sugar whole gut permeability assay. J Chromatogr B Analyt Technol Biomed Life Sci 2011; 879:2794-801. [PMID: 21862422 DOI: 10.1016/j.jchromb.2011.08.002] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2011] [Revised: 08/01/2011] [Accepted: 08/02/2011] [Indexed: 12/17/2022]
Abstract
Many pathophysiological conditions are associated with increased gastrointestinal permeability, reflecting an elevated risk of endotoxaemia, inflammation, and sepsis. Permeability tests are increasingly used in clinical practice to obtain information on gastrointestinal functioning, but tests are often restricted to the small intestine, and require large oral sugar doses. Therefore, a novel multi-sugar assay was developed, allowing assessment of whole gut permeability changes in urinary and plasma samples collected at regular intervals from 10 healthy volunteers at baseline and after intake of monosaccharides (rhamnose and erythritol) and disaccharides (sucrose, lactulose, and sucralose). Samples were analyzed by isocratic cation-exchange LC-MS. Sample preparation and detection conditions were optimized. After centrifugation, chromatographic separation was achieved on an IOA-1000 column set at 30°C. Column effluent was mixed with ammonia for sugar-ammonium adduct formation. The lower limit of detection was 0.05 μmol/L for disaccharides and 0.1 μmol/L for monosaccharides. Linearity for each probe was between 1 and 1000 μmol/L (R(2): 0.9987-0.9999). Coefficients of variation were <5% in urine, and <9% in plasma. Recovery data were within the 90% to 110% range at all spiked concentrations. This highly sensitive novel LC-MS approach resulted in a significant decrease of the detection limit for all sugar probes, allowing a 5-fold reduction of the commonly used lactulose dose and the addition of sugar probes to also assess the gastroduodenal and colon permeability. In combination with its extended application in plasma, these features make the novel assay a promising tool in the assessment of site-specific changes in gastrointestinal permeability in clinical practice.
Collapse
Affiliation(s)
- Kim van Wijck
- Top Institute Food and Nutrition, Wageningen, The Netherlands
| | | | | | | | | |
Collapse
|
42
|
Ullah S, Wahren J, Beck O. Precise determination of glucose-d2/glucose ratio in human serum and plasma by APCI LC-MS/MS. Scandinavian Journal of Clinical and Laboratory Investigation 2009; 69:837-42. [DOI: 10.3109/00365510903307954] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
43
|
Verardo G, Duse I, Callea A. Analysis of underivatized oligosaccharides by liquid chromatography/electrospray ionization tandem mass spectrometry with post-column addition of formic acid. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2009; 23:1607-1618. [PMID: 19408275 DOI: 10.1002/rcm.4047] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Underivatized oligosaccharides were analyzed by electrospray ionization (ESI) using a linear ion trap mass spectrometer in the negative ion mode with post-column addition of an aqueous solution of formic acid. Under these conditions all oligosaccharides showed the presence of the corresponding formate adduct [M + HCOO](-) with high intensity and easy subsequent low-energy collision-induced dissociation (CID) fragmentation using successive MS(n) experiments. A careful examination of the mass spectra obtained from these MS(n) experiments pointed out some significant differences useful to identify and quantify the single components in mixtures of coeluted disaccharides. This new sensitive and rapid method was successfully applied to the quantification of oligosaccharides in some juices minimizing sample handling.
Collapse
Affiliation(s)
- Giancarlo Verardo
- Department of Chemical Sciences and Technology, University of Udine, I-33100 Udine, Italy.
| | | | | |
Collapse
|
44
|
Hammad LA, Saleh MM, Novotny MV, Mechref Y. Multiple-reaction monitoring liquid chromatography mass spectrometry for monosaccharide compositional analysis of glycoproteins. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2009; 20:1224-1234. [PMID: 19318280 DOI: 10.1016/j.jasms.2009.02.022] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/25/2008] [Revised: 02/10/2009] [Accepted: 02/10/2009] [Indexed: 05/27/2023]
Abstract
A simple, sensitive, and rapid quantitative LC-MS/MS assay was designed for the simultaneous quantification of free and glycoprotein bound monosaccharides using a multiple reaction monitoring (MRM) approach. This study represents the first example of using LC-MS/MS methods to simultaneously quantify all common glycoprotein monosaccharides, including neutral and acidic monosaccharides. Sialic acids and reduced forms of neutral monosaccharides are efficiently separated using a porous graphitized carbon column. Neutral monosaccharide molecules are detected as their alditol acetate anion adducts [M + CH(3)CO(2)](-) using electrospray ionization in negative ion MRM mode, while sialic acids are detected as deprotonated ions [M - H](-). The new method exhibits very high sensitivity to carbohydrates with limits of detection as low as 1 pg for glucose, galactose, and mannose, and below 10 pg for other monosaccharides. The linearity of the described approach spans over three orders of magnitudes (pg to ng). The method effectively quantified monosaccharides originating from as little as 1 microg of fetuin, ribonuclease B, peroxidase, and alpha(1)-acid glycoprotein human (AGP) with results consistent with literature values and with independent CE-LIF measurements. The method is robust, rapid, and highly sensitive. It does not require derivatization or postcolumn addition of reagents.
Collapse
Affiliation(s)
- Loubna A Hammad
- METACyt Biochemical Analysis Center, Department of Chemistry, Indiana University, Bloomington, Indiana 47405, USA
| | | | | | | |
Collapse
|
45
|
Lian LY, Al-Helal M, Roslaini AM, Fisher N, Bray PG, Ward SA, Biagini GA. Glycerol: an unexpected major metabolite of energy metabolism by the human malaria parasite. Malar J 2009; 8:38. [PMID: 19267910 PMCID: PMC2660357 DOI: 10.1186/1475-2875-8-38] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2009] [Accepted: 03/06/2009] [Indexed: 11/28/2022] Open
Abstract
Background Malaria is a global health emergency, and yet our understanding of the energy metabolism of the principle causative agent of this devastating disease, Plasmodium falciparum, remains rather basic. Glucose was shown to be an essential nutritional requirement nearly 100 years ago and since this original observation, much of the current knowledge of Plasmodium energy metabolism is based on early biochemical work, performed using basic analytical techniques (e.g. paper chromatography), carried out almost exclusively on avian and rodent malaria. Data derived from malaria parasite genome and transcriptome studies suggest that the energy metabolism of the parasite may be more complex than hitherto anticipated. This study was undertaken in order to further characterize the fate of glucose catabolism in the human malaria parasite, P. falciparum. Methods Products of glucose catabolism were determined by incubating erythrocyte-freed parasites with D-[1-13C] glucose under controlled conditions and metabolites were identified using 13C-NMR spectroscopy. Results Following a 2 h incubation of freed-P. falciparum parasites with 25 mM D-[1-13C] glucose (n = 4), the major metabolites identified included; [3-13C] lactate, [1,3-13C] glycerol, [3-13C] pyruvate, [3-13C] alanine and [3-13C] glycerol-3-phosphate. Control experiments performed with uninfected erythrocytes incubated under identical conditions did not show any metabolism of D-[1-13C] glucose to glycerol or glycerol-3-phosphate. Discussion The identification of glycerol as a major glucose metabolite confirms the view that energy metabolism in this parasite is more complex than previously proposed. It is hypothesized here that glycerol production by the malaria parasite is the result of a metabolic adaptation to growth in O2-limited (and CO2 elevated) conditions by the operation of a glycerol-3-phosphate shuttle for the re-oxidation of assimilatory NADH. Similar metabolic adaptations have been reported previously for other microaerobic/anaerobic organisms, such as yeast, rumen protozoa and human parasitic protozoa. Conclusion These data highlight the need to re-evaluate the carbon and redox balance of this important human pathogen, ultimately leading to a better understanding of how the parasite is able to adapt to the variable environments encountered during parasite development and disease progression.
Collapse
Affiliation(s)
- Lu-Yun Lian
- School of Biological Sciences, University of Liverpool, Liverpool, UK.
| | | | | | | | | | | | | |
Collapse
|
46
|
Holtz KA, Stephens BR, Sharoff CG, Chipkin SR, Braun B. The effect of carbohydrate availability following exercise on whole-body insulin action. Appl Physiol Nutr Metab 2008; 33:946-56. [PMID: 18923570 DOI: 10.1139/h08-077] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
One bout of exercise enhances insulin-stimulated glucose uptake (insulin action), but the effect is blunted by consumption of carbohydrate-containing food after exercise. The independent roles of energy and carbohydrate in mediating post-exercise insulin action have not been systematically evaluated in humans. The purpose of this study was to determine if varying carbohydrate availability, with energy intake held constant, mediates post-exercise insulin action. Ten young (21 +/- 2 y, overweight (body fat 37% +/- 3%) men and women completed 3 conditions in random order: (i) no-exercise (BASE), (ii) exercise with energy balance but carbohydrate deficit (C-DEF), and (iii) exercise with energy and carbohydrate balance (C-BAL). In the exercise conditions, subjects expended 30% of total daily energy expenditure on a cycle ergometer at 70% VO2 peak. Following exercise, subjects consumed a meal that replaced expended energy (~3000 kJ) and was either balanced (intake = expenditure) or deficient (-100 g) in carbohydrate. Twelve hours later, insulin action was measured by continuous infusion of glucose with stable isotope tracer (CIG-SIT). Changes in insulin action were evaluated using a one-way ANOVA with repeated measures. During CIG-SIT, non-oxidative glucose disposal (i.e., glucose storage) was higher in C-DEF than in BASE (27.2 +/- 3.2 vs. 16.9 +/- 3.5 micromol.L-1.kg-1.min-1, p < 0.05). Conversely, glucose oxidation was lower in C-DEF (8.6 +/- 1.3 micromol.L-1.kg-1.min-1) compared with C-BAL (12.2 +/- 1.2 micromol.L-1.kg-1.min-1), and BASE (17.1 +/- 2.2 micromol.L-1.kg-1.min-1), p < 0.05). Fasting fat oxidation was higher in C-DEF than in BASE (109.8 +/- 10.5 vs. 80.7 +/- 9.6 mg.min-1, p < 0.05). In C-DEF, enhanced insulin action was correlated with the magnitude of the carbohydrate deficit (r = 0.82, p < 0.01). Following exercise, re-feeding expended energy, but not carbohydrate, increased fasting fat oxidation, and shifted insulin-mediated glucose disposal toward increased storage and away from oxidation.
Collapse
Affiliation(s)
- Kaila A Holtz
- Energy Metabolism Laboratory, Department of Kinesiology, University of Massachusetts, Amherst, MA 01003, USA
| | | | | | | | | |
Collapse
|
47
|
Detection and pharmacokinetics of alginate oligosaccharides in mouse plasma and urine after oral administration by a liquid chromatography/tandem mass spectrometry (LC-MS/MS) method. Biosci Biotechnol Biochem 2008; 72:2184-90. [PMID: 18685205 DOI: 10.1271/bbb.80270] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
A sensitive and simple liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed for the detection of alginate oligosaccharides (AOs) in mouse plasma and urine after oral administration. In an AO mixture, dimer, trimer, and tetramer were detected by LC-MS/MS equipped with an anion-exchange column with extremely high sensitivity. By this method, we detected certain levels of AOs in samples prepared from mouse plasma and urine after a single oral administration of the AO mixture. Based on a calibration curve made with an AO trimer peak area as a standard, the maximum plasma and urine concentrations of AOs were estimated to be 24.5 microg/ml at 5 min and 425.5 microg/ml at 30 min, respectively. These results suggest that the LC-MS/MS method is well suited to pharmacokinetic analysis of AOs in an in vivo system, and that some of orally administered AOs, at least from dimer to tetramer, are absorbed by digestive organs promptly, and that unaltered, these oligomers were excreted into an urine after a single oral administration to a mouse.
Collapse
|
48
|
Stephens BR, Sautter JM, Holtz KA, Sharoff CG, Chipkin SR, Braun B. Effect of timing of energy and carbohydrate replacement on post-exercise insulin action. Appl Physiol Nutr Metab 2008; 32:1139-47. [PMID: 18059588 DOI: 10.1139/h07-126] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The nutritional environment surrounding an exercise bout modulates post-exercise insulin action. The purpose of this study was to determine how timing energy and carbohydrate replacement proximate to an exercise bout influences exercise-enhanced insulin action. To create an appropriate baseline, sensitivity to insulin was reduced in 9 healthy young men (n=6) and women (n=3) by 2 days of energy surplus and detraining. Then, insulin action (glucose uptake per unit plasma insulin) was assessed by stable isotope dilution during a continuous glucose infusion 12 h after a standardized meal under 4 conditions. In 3 conditions, the meal replaced the energy and carbohydrate expended during an exercise bout (62.9+/-2.8 min cycle ergometry at 65% VO2 peak followed by ten 30 s sprints). The meal was given before (Pre), immediately after (ImmPost), or 3 h after exercise (Delay). The 4th condition was a no-exercise control (Control). Data were analyzed using linear mixed-effects models with planned contrasts. Relative to Control, insulin action increased by 22% in Pre (p=0.05), 44% in ImmPost (p<0.01), and 19% in Delay (p=0.09). Non-oxidative disposal was higher, and oxidative disposal was lower in ImmPost relative to Control and Pre (p<0.05). Hepatic glucose production was suppressed by the infusion to a greater extent in Pre and Delay (76.9%+/-8.8% and 81.2%+/-4.7%) compared with ImmPost (64.7%+/-10.0%). A bout of exercise enhances insulin action even when expended energy and carbohydrate are replaced. Further, timing of energy and carbohydrate consumption subtly modulates the effectiveness of exercise to enhance insulin action.
Collapse
Affiliation(s)
- Brooke R Stephens
- Energy Metabolism Laboratory, Department of Kinesiology, School of Public Health and Health Sciences, University of Massachusetts, Amherst, MA 01003, USA
| | | | | | | | | | | |
Collapse
|
49
|
Thevis M, Guddat S, Flenker U, Schänzer W. Quantitative analysis of urinary glycerol levels for doping control purposes using gas chromatography-mass spectrometry. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2008; 14:117-125. [PMID: 18708691 DOI: 10.1255/ejms.919] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
The administration of glycerol to endurance athletes results in an increased fluid retention and improved performance, particularly under hot and humid conditions. Consequently, glycerol is considered relevant for sports drug testing and methods for its detection in urine specimens are required. A major issue in this regard is the natural occurrence of trace amounts of glycerol in human urine, which necessitates a quantitative analysis and the determination of normal urinary glycerol levels under various sporting conditions. A quantitative method was established using a gas chromatography/isotope-dilution mass spectrometry-based approach that was validated with regard to lower limit of detection (0.3 microg mL(-1)), lower limit of quantification (0.9 microg mL(-1)), specificity, linearity (1.0-98.0 microg mL(-1)), intraday and interday precision (<20% at 2.4, 24.1 and 48.2 microg mL(-1)) as well as accuracy (92-110%). Sample aliquots of 20 microL were enriched with five-fold deuterated glycerol, dried and derivatised using N-methyl-trimethylsilyltrifluoroacetamide (MSTFA) before analysis. The established method was applied to a total of 1039 doping control samples covering various sport disciplines (349 endurance samples, 286 strength sport samples, 325 game sport samples and 79 other samples) in- and out-of-competition, which provided quantitative information about the glycerol content commonly observed in elite athletes' urine samples. About 85% of all specimens yielded glycerol concentrations < 20.0 microg mL(-1) and few reached values up to 132.6 microg mL(-1). One further sample, however, was found to contain 2690 microg mL(-1), which might indicate the misuse of glycerol, but no threshold for urinary glycerol concentrations has been established yet due to the lack of substantial data. Based on the results obtained from the studied reference population, a threshold for glycerol levels in urine set at 200 microg mL(-1) is suggested, which provides a tool to doping control laboratories to test for the misuse of this agent in elite and amateur sport.
Collapse
Affiliation(s)
- Mario Thevis
- Center for Preventive Doping Research, Institute of Biochemistry, German Sport University Cologne, Carl-Diem Weg 6, 50933 Cologne, Germany.
| | | | | | | |
Collapse
|
50
|
de Graaf AA, Venema K. Gaining insight into microbial physiology in the large intestine: a special role for stable isotopes. Adv Microb Physiol 2007; 53:73-168. [PMID: 17707144 DOI: 10.1016/s0065-2911(07)53002-x] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The importance of the human large intestine for nutrition, health, and disease, is becoming increasingly realized. There are numerous indications of a distinct role for the gut in such important issues as immune disorders and obesity-linked diseases. Research on this long-neglected organ, which is colonized by a myriad of bacteria, is a rapidly growing field that is currently providing fascinating new insights into the processes going on in the colon, and their relevance for the human host. This review aims to give an overview of studies dealing with the physiology of the intestinal microbiota as it functions within and in interaction with the host, with a special focus on approaches involving stable isotopes. We have included general aspects of gut microbial life as well as aspects specifically relating to genomic, proteomic, and metabolomic studies. A special emphasis is further laid on reviewing relevant methods and applications of stable isotope-aided metabolic flux analysis (MFA). We argue that linking MFA with the '-omics' technologies using innovative modeling approaches is the way to go to establish a truly integrative and interdisciplinary approach. Systems biology thus actualized will provide key insights into the metabolic regulations involved in microbe-host mutualism and their relevance for health and disease.
Collapse
Affiliation(s)
- Albert A de Graaf
- Wageningen Center for Food Sciences, PO Box 557, 6700 AN Wageningen, The Netherlands
| | | |
Collapse
|