1
|
Impact of intestinal ultrasound on the management of patients with inflammatory bowel disease: how to apply scientific evidence to clinical practice. Dig Liver Dis 2020; 52:9-18. [PMID: 31732443 DOI: 10.1016/j.dld.2019.10.004] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/06/2019] [Revised: 09/27/2019] [Accepted: 10/08/2019] [Indexed: 12/11/2022]
Abstract
Technological improvements and growing sonographers' expertise boost the role of intestinal ultrasound (IUS) in assessing patients with inflammatory bowel diseases (IBD). Non-invasiveness, low cost and good reproducibility make IUS attractive. Leveraging on the Authors' long-term field experience, this review focuses on the IUS role in IBD patients' clinical management. For detecting IBD, particularly Crohn's disease, the IUS parameters - above all the evidence of a thickened bowel wall (BWT) - show very good diagnostic accuracy similar to that of MRI or CT scan. The standard IUS parameters are not accurate enough to detect inflammatory activity, but intravenous contrast-enhanced US (CEUS) is highly accurate in ruling active inflammation out. However, its routinely use remains limited in clinical practice and its parameters need standardization. IUS is accurate in detecting IBD main complications: in particular, fistulae and abscesses. As to stenosis the recent introduction of IUS-based elastographic techniques allows to differentiate prevalently inflammatory from highly fibrotic strictures. IUS proves valid also for monitoring IBD patients. In particular, the evidence of transmural healing, defined as BWT normalization, has got an important prognostic meaning, as associated with better long-term clinical outcomes. Post-surgery CD recurrence can be suggested by early IUS assessment.
Collapse
|
2
|
Role of Bowel Ultrasound in the Diagnosis and Follow-up of Patients with Crohn's Disease. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:725-734. [PMID: 28185694 DOI: 10.1016/j.ultrasmedbio.2016.12.014] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/13/2016] [Revised: 11/18/2016] [Accepted: 12/20/2016] [Indexed: 06/06/2023]
Abstract
Crohn's disease (CD) is an inflammatory chronic bowel disorder; it can involve the whole gastrointestinal tract, but its localization in the ileum or colon is most common. The reference standard for the diagnosis of CD is ileocolonoscopy with histologic assessment. The reference standard for the detection of any complications is surgery. However, imaging techniques have an important role both in the detection/localization of CD and in the follow-up of CD patients. In the last few years, the technical development of ultrasound equipment, the advent of new technologies such as elastography and mostly the increased expertise of sonographers have boosted the role of bowel ultrasound in assessment of the gastrointestinal tract. In fact, bowel ultrasound is particularly attractive thanks to its widespread availability, non-invasiveness, low cost and good reproducibility, as it can be easily repeated during follow-up. The aim of this article is to provide an extensive overview of the actual role of bowel ultrasound in the detection and follow-up of patients with CD.
Collapse
|
3
|
Bowel Ultrasonography in the Management of Crohn's Disease. A Review with Recommendations of an International Panel of Experts. Inflamm Bowel Dis 2016; 22:1168-83. [PMID: 26958988 DOI: 10.1097/mib.0000000000000706] [Citation(s) in RCA: 111] [Impact Index Per Article: 13.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
BACKGROUND Bowel ultrasonography (US) is considered a useful technique for assessing mural inflammation and complications in Crohn's disease (CD). The aim of this review is to appraise the evidence on the accuracy of bowel US for CD. In addition, we aim to provide recommendations for its optimal use. METHODS Publications were identified by literature search from 1992 to 2014 and selected based on predefined criteria: 15 or more patients; bowel US for diagnosing CD, complications, postoperative recurrence, activity; adequate reference standards; prospective study design; data reported to allow calculation of sensitivity, specificity, agreement, or correlation values; articles published in English. RESULTS The search yielded 655 articles, of which 63 were found to be eligible and retrieved as full-text articles for analysis. Bowel US showed 79.7% sensitivity and 96.7% specificity for the diagnosis of suspected CD, and 89% sensitivity and 94.3% specificity for initial assessment in established patients with CD. Bowel US identified ileal CD with 92.7% sensitivity, 88.2% specificity, and colon CD with 81.8% sensitivity, 95.3% specificity, with lower accuracy for detecting proximal lesions. The oral contrast agent improves the sensitivity and specificity in determining CD lesions and in assessing sites and extent. CONCLUSIONS Bowel US is a tool for evaluation of CD lesions in terms of complications, postoperative recurrence, and monitoring response to medical therapy; it reliably detects postoperative recurrence and complications, as well as offers the possibility of monitoring disease progression.
Collapse
|
4
|
Failure of gastroenterologists to apply intestinal ultrasound in inflammatory bowel disease in the Asia-Pacific: a need for action. J Gastroenterol Hepatol 2015; 30:446-52. [PMID: 25529767 DOI: 10.1111/jgh.12871] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 12/16/2014] [Indexed: 12/14/2022]
Abstract
Intestinal ultrasound (IUS) is a cheap, noninvasive, risk-free procedure that is significantly underutilized in the diagnosis and management of patients with inflammatory bowel disease (IBD) in the Asia-Pacific region. More cost-effective methods of monitoring disease activity are required in light of the increasing global burden of IBD (especially in Asia), the advent of personalized medicine, and the rising cost of healthcare. IUS is a prime example of a technique that meets these needs. Its common clinical applications include assessing the activity and complications of IBD. In continental Europe, countries such as Germany and Italy use this imaging tool as the standard of care and have integrated it into management protocols. There are formal training programs in these countries to train gastroenterologists in IUS, and it is used in an outpatient setting during patient consultations. Barriers to its use in the Asia-Pacific region include lack of experience and research data, and there are few established centers with active training programs. These concerns can be addressed by investing more in IUS service provision and by increasing allocation of resources toward local research and training. Increased uptake of IUS will ultimately benefit patients with IBD.
Collapse
|
5
|
Bowel ultrasonography as an aid for diagnosis of intestinal acute graft-versus-host-disease after allogeneic haematopoietic stem cell transplantation. Dig Liver Dis 2013; 45:899-904. [PMID: 23680035 DOI: 10.1016/j.dld.2013.04.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/05/2012] [Revised: 04/01/2013] [Accepted: 04/10/2013] [Indexed: 12/11/2022]
Abstract
OBJECTIVE Aim of our prospective study was to investigate accuracy of bowel ultrasonography in detecting gastrointestinal acute graft versus host disease (GVHD), when using clinical assessment as gold standard. In a subgroup of patients, bowel ultrasonography was compared with colonoscopy and histology in diagnosing of gastrointestinal acute GVHD. METHODS Fifty-two patients underwent allogeneic hematopoietic stem cell transplantation and developed gastrointestinal symptoms. RESULTS Clinical assessment lead to a diagnosis of gastrointestinal acute GVHD in 17/52 patients, no gastrointestinal acute GVHD was detected in 20/52 patients, while 15 patients were not able to complete the study. Bowel ultrasonography detected either bowel wall thickness of the ileum and the colon or dilation in 16/17 patients and showed 94% sensitivity (95% CI 0.69-0.99), 95% specificity (95% CI 0.73-0.99), and 94.5% accuracy. Colonoscopy was performed in 13/52 patients, showing gastrointestinal acute GVHD in 11/13. In these 11 patients, histology confirmed the diagnosis of gastrointestinal acute GVHD, and bowel ultrasonography detected findings compatible with gastrointestinal acute GVHD in all 11 patients, and was negative in the 2 patients with no gastrointestinal acute GVHD. CONCLUSION Bowel ultrasonography can be considered a valuable tool to add to clinical assessment for patients with suspected gastrointestinal acute GVHD for addressing a prompt and appropriate treatment.
Collapse
|
6
|
Ultrasound as a diagnostic tool in detecting active Crohn's disease: a meta-analysis of prospective studies. Eur Radiol 2013; 24:26-33. [PMID: 23921767 DOI: 10.1007/s00330-013-2973-0] [Citation(s) in RCA: 72] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2013] [Revised: 06/20/2013] [Accepted: 07/09/2013] [Indexed: 12/22/2022]
Abstract
OBJECTIVES To evaluate the diagnostic accuracy of ultrasound in assessing active Crohn's disease (CD) in adults. METHODS We systematically searched PubMed, EMBASE, Web of Science and the Cochrane Library for prospective studies in which ultrasound was performed to evaluate active CD in adults from January 1993 to April 2013. Pooled sensitivity, specificity, positive and negative likelihood ratios (LR+ and LR-) and diagnostic odds ratios (DORs) in a per-patient-based analysis were estimated. Additionally, the area under the receiver-operating characteristic (ROC) curve was calculated to measure the diagnostic accuracy of ultrasound in patients with known or suspected CD. RESULTS Fifteen studies involving 1,558 patients were included in this meta-analysis. Overall, the pooled sensitivity (0.88) and LR- (0.14) were not heterogeneous, whereas the pooled specificity (0.97, I(2) = 72.9 %) and LR + (15.10, I(2) = 71.8 %) were. The DOR of ultrasound for assessing active CD was 121.70, with significant heterogeneity (I(2) = 63.3 %). A symmetrical summary ROC curve was plotted showing that the area under the curve was 0.94, indicating good diagnostic accuracy. Meta-regression and subgroup analysis showed that the disease location may be a major cause of heterogeneity. CONCLUSIONS This meta-analysis suggests that ultrasound has high diagnostic accuracy in detecting active CD in adults, especially for small bowel CD. KEY POINTS • Ultrasound can detect active Crohn's disease (CD). • A meta-analysis of ultrasound for detecting active CD was carried out. • This revealed that ultrasound has high diagnostic accuracy for detecting CD.
Collapse
|
7
|
Ultrasound of the small bowel in Crohn's disease. Int J Inflam 2012; 2012:964720. [PMID: 22518346 PMCID: PMC3299330 DOI: 10.1155/2012/964720] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2011] [Revised: 11/24/2011] [Accepted: 12/09/2011] [Indexed: 02/01/2023] Open
Abstract
Several radiological and endoscopic techniques are now available for the study of inflammatory bowel diseases. In everyday practice, the choice of the technique to be used depends upon its availability and a careful evaluation of diagnostic accuracy, clinical usefulness, safety, and cost. The recent development of innovative and noninvasive imaging techniques has led to a new and exciting area in the exploration of the gastrointestinal tract, especially in Crohn's disease patients by using ultrasound with oral or intravenous contrast.
Collapse
|
8
|
Noninvasive imaging of the small bowel in Crohn's disease: the final frontier. Inflamm Bowel Dis 2011; 17:1987-99. [PMID: 21287661 DOI: 10.1002/ibd.21598] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/03/2010] [Accepted: 11/03/2010] [Indexed: 02/06/2023]
Abstract
The substantial morbidity and mortality associated with Crohn's disease underlines the importance of accurate assessment at presentation, during follow-up, when investigating complications, and when evaluating the response to therapeutic interventions. Accurate methods are required to quantify the severity and extent of disease.
Collapse
|
9
|
Abstract
The evaluation of inflammatory activity in Crohn's disease (CD), a crucial aspect of treatment planning and monitoring, is currently based on a sum of clinical data and imaging findings. Among the contrast enhanced cross-sectional imaging techniques (CE-US, CE-CT, CE-MR), CE-US is less invasive, more comfortable for the patient, and has significant diagnostic accuracy. In addition, it is a portable, easily repeatable, well tolerated, and ionizing radiation-free imaging modality. CE-US has been introduced as effective method in the quantitative and qualitative evaluation of CD inflammatory activity. CE-US might help in characterizing bowel-wall thickening by differentiating inflammatory neovascularisation, edema, and fibrosis. The recent chance to evaluate the bowel-wall stiffness by US elastography imaging could allow further assessment of fibrosis that characterizes the evolution of the inflammatory activity.
Collapse
|
10
|
Abstract
Transabdominal bowel sonography is a fast, efficient, and cheap way of examining the intestines. It is also virtually hazard-free and well accepted by patients. During the last 20 years, it has been established as a procedure for detecting bowel disease early in the diagnostic workup. Although rather unspecific, the method is sensitive for detection of bowel disease and can be applied to find the extent and location of inflammatory bowel disease. In patients with known ulcerative colitis and Crohn disease, it can also be used for follow-up because it is easily repeatable and radiation-free. Because it can be applied to find both intraluminal and peri-intestinal pathological features, it is a particularly valuable tool for the detection of complications of Crohn disease as stenosis, fistulas, and abscesses. Neither B-mode nor Doppler techniques have been proven obviously useful in categorizing disease activity, but new techniques using intravenous contrast might come closer to solving this question. Finally, recent longitudinal studies using transabdominal bowel sonography show that it can also give important prognostic information and be used for monitoring the effect of therapy.
Collapse
|
11
|
Contrast-enhanced ultrasonographic evaluation of inflammatory activity in Crohn's disease. Gastroenterology 2009; 137:43-52. [PMID: 19422826 DOI: 10.1053/j.gastro.2009.03.062] [Citation(s) in RCA: 160] [Impact Index Per Article: 10.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2008] [Revised: 01/20/2009] [Accepted: 03/10/2009] [Indexed: 01/03/2023]
Abstract
BACKGROUND & AIMS We sought to test the diagnostic accuracy of ultrasound (US), color Doppler US (CD-US), and contrast-enhanced US (CE-US) in the evaluation of inflammatory activity in patients with Crohn's disease (CD), and to correlate the findings of these sonographic studies with inflammatory activity, as scored by the CD activity index (CDAI). METHODS Patients with CD were enrolled in the study. Radiologists performing the scans were blinded to clinical status. Baseline US, CD-US, and CE-US examinations were conducted with high-frequency probes (8-14 and 5-7 MHz) before and after injection of sulfur hexafluoride-filled microbubbles. The diagnostic accuracy of baseline US, CD-US, and CE-US were calculated by using the endoscopic and histologic findings as reference standards and correlated with the CDAIs by using the Pearson linear correlation coefficient. RESULTS Forty-seven patients (20 men; 27 women; mean age +/- SD, 38 +/- 14 years) with a CDAI > 150 (n = 30) or < 150 (n = 17), were recruited. CE-US showed the highest performance, with 93.5% sensitivity, 93.7% specificity, and 93.6% overall accuracy. CE-US revealed 3 bowel wall perfusion patterns after microbubble injection: submucosal enhancement and inward and outward transparietal enhancement. The linear correlation coefficient for CE-US versus CDAI was 0.74 (P < .0001); for baseline US (assessing thickness, length, and multilayer appearance of the diseased bowel) versus the CDAI, the coefficients were 0.68 (P < .0001), 0.47 (P = .0009), and 0.60 (P < .0001), respectively; and for CD-US versus CDAI the coefficient was 0.73 (P < .0001). CONCLUSIONS CE-US has a high sensitivity and specificity in detecting inflammatory activity and a strong correlation with the CDAI.
Collapse
|
12
|
The diagnostic value of small bowel wall vascularity after sulfur hexafluoride-filled microbubble injection in patients with Crohn's disease. Correlation with the therapeutic effectiveness of specific anti-inflammatory treatment. Eur J Radiol 2008; 69:438-44. [PMID: 19070446 DOI: 10.1016/j.ejrad.2008.10.029] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2008] [Accepted: 10/24/2008] [Indexed: 12/21/2022]
Abstract
PURPOSE To assess the value of small bowel wall vascularity after microbubble contrast agent injection in evaluating the therapeutic effectiveness of specific anti-inflammatory treatment in patients with Crohn's disease. MATERIALS AND METHODS Fifteen patients (7 male and 8 female; mean age+/-SD, 40 years+/-6) with a biopsy-proven diagnosis of Crohn's disease--Crohn's disease activity index (CDAI)>150 (n=12 patients) or <150 (n=3)--involving the terminal loop of the small bowel (wall thickness>5 mm) were included. In each patient the terminal loop was scanned by contrast-enhanced ultrasound (CEUS) after sulfur hexafluoride-filled microbubble injection before and after 6-month anti-inflammatory treatment. The vascularity of the terminal loop was quantified in gray-scale levels (0-255) by a manually drawn ROI encompassing the thickened bowel wall and it was correlated with CDAI. RESULT Before the beginning of the specific treatment all patients revealed diffuse transparietal contrast enhancement after microbubble injection, except for 3 patients who revealed contrast enhancement limited to the submucosa. In 13 patients the slope of the first ascending tract and the area under the enhancement curve were significantly lower after anti-inflammatory treatment (P<0.05; Wilcoxon test) with a significant correlation with the CDAI score (rho=0.85, P<0.05). In 2 patients no significant vascularity changes were found even though a mild reduction of CDAI score was identified (from 200 to 150 gray-scale levels). CONCLUSION CEUS is a useful method to assess the therapeutic effectiveness of specific medical anti-inflammatory treatment in patients with Crohn's disease.
Collapse
|
13
|
Reproducibility of bowel ultrasonography in the evaluation of Crohn's disease. Dig Liver Dis 2008; 40:860-6. [PMID: 18583205 DOI: 10.1016/j.dld.2008.04.006] [Citation(s) in RCA: 92] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/17/2007] [Revised: 04/15/2008] [Accepted: 04/18/2008] [Indexed: 12/11/2022]
Abstract
BACKGROUND Bowel ultrasonography is increasingly used in the detection and follow-up of patients with Crohn's disease, but a limitation to its further diffusion is the lack of standardisation of ultrasonography parameters. AIMS This study aimed to standardise the most common bowel ultrasonography parameters in order to develop an unequivocal imaging interpretation and to assess bowel ultrasonography reproducibility. PATIENTS Twenty patients with Crohn's disease were examined. METHODS Six ultrasonographers (mean bowel ultrasonography experience=16 years) performed the study. They chose and discussed a common assessment methodology concerning eight ultrasonography parameters: bowel wall thickness, bowel wall pattern, bowel wall blood flow, enlarged mesenteric lymph nodes, mesenteric hypertrophy, abdominal free fluid, and stenosis or fistulae at four preliminary meetings. The day of the study operators were randomised to two rooms where they independently and in turn performed ultrasonography scans. Interobserver agreement was scored by kappa statistics. RESULTS Excellent k values were observed for bowel wall thickness (0.72-1). k Values were poor for bowel wall pattern (-0.22-0.85) and good for bowel wall blood flow (0.53-0.89). The presence of lymph nodes was reproducible (0.56-0.90) except in one case (0.25). Concordance on free fluid was excellent (0.85-1), whereas that on mesenteric hypertrophy was generally poor (0.14-0.69). Agreement was excellent for stenosis (0.81-1) whereas that for fistula was fair in room abscesses (0.31-0.48) and very good in room B (0.87-1). CONCLUSION Bowel ultrasonography signs used in Crohn's disease can be standardised as most of them showed a fair to good reproducibility. In particular, bowel wall thickness, the most relevant parameter for Crohn's disease detection, showed an excellent reproducibility.
Collapse
|
14
|
Abstract
Improvements in the ultrasound examination of bowel disease have registered in the last years the introduction of new technologies regarding high frequency probes (US), highly sensitive color or power Doppler units (CD-US), and the development of new non-linear technologies that optimize detection of contrast agents. Contrast-enhanced ultrasound (CE-US) most importantly increases the results in sonographic evaluation of Crohn disease inflammatory activity. CE-US has become an imaging modality routinely employed in the clinical practice for the evaluation of parenchymal organs due to the introduction of new generation microbubble contrast agents which persist in the bloodstream for several minutes after intravenous injection. The availability of high frequency dedicated contrast-specific US techniques provide accurate depiction of small bowel wall perfusion due to the extremely high sensitivity of non-linear signals produced by microbubble insonation. In Crohn's disease, CE-US may characterize the bowel wall thickness by differentiating fibrosis from edema and may grade the inflammatory disease activity by assessing the presence and distribution of vascularity within the layers of the bowel wall (submucosa alone or the entire bowel wall). Peri-intestinal inflammatory involvement can be also characterized. CE-US can provide prognostic data concerning clinical recurrence of the inflammatory disease and evaluate the efficacy of drugs treatments.
Collapse
|
15
|
Oral contrast-enhanced sonography for the diagnosis and grading of postsurgical recurrence of Crohn's disease. Inflamm Bowel Dis 2008; 14:1240-5. [PMID: 18398896 DOI: 10.1002/ibd.20469] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
BACKGROUND Postsurgical recurrence (PSR) is very common in patients with Crohn's disease (CD) and previous surgery. Endoscopy is crucial for the diagnosis of PSR, also showing high prognostic value. Bowel sonography (BS) with or without oral contrast enhancement (OCBS) is accurate for CD diagnosis but its role in PSR detection and grading is poorly investigated. The aim was to evaluate the diagnostic accuracy of BS and OCBS for PSR compared to the endoscopical Rutgeerts's grading system. METHODS We prospectively performed endoscopy, BS, and OCBS in 40 CD patients with previous bowel resection to provide evidence of possible PSR. Endoscopy, BS, and OCBS were executed 1 year after surgery, with PSR diagnosis and grading made in accordance with Rutgeerts. BS and OCBS were considered suggestive for PSR in the presence of bowel wall thickness (BWT) >3 mm. OCBS was performed after ingestion of 750 mL of polyethylene glycol (PEG). Also, a receiver operating characteristic (ROC) curve was constructed in order to define the best cutoff of BWT to discriminate mild from severe PSR (grade 0-2 versus 3-4 of Rutgeerts) for both BS and OCBS. RESULTS In all, 22 out of the 40 CD showed an endoscopic evidence of PSR (55%). A severe PSR was present in 14 patients (64%). Sensitivity, specificity, and positive and negative predictive values were 77%, 94%, 93%, and 80% for BS, and 82%, 94%, 93%, and 84% for OCBS. On the ROC curve a BWT >5 mm showed sensitivity, specificity, and positive and negative predictive values of 93%, 96%, 88%, and 97% for the diagnosis of severe PSR at BS, while a BWT >4 mm was the best cutoff differentiating the mild from the severe CD recurrence for OCBS, with a sensitivity, specificity, and positive and negative predictive values of 86%, 96%, 97%, and 79%, respectively. CONCLUSIONS Both BS and OCBS show good sensitivity and high specificity for the diagnosis of PSR in CD, with a BWT >5 mm for BS and BWT >4 mm for OCBS strongly indicative of severe endoscopic PSR. Accordingly, these techniques could replace endoscopy for the diagnosis and grading of PSR in many cases.
Collapse
|
16
|
Inflammatory bowel disease diagnosed with US, MR, scintigraphy, and CT: meta-analysis of prospective studies. Radiology 2008; 247:64-79. [PMID: 18372465 DOI: 10.1148/radiol.2471070611] [Citation(s) in RCA: 402] [Impact Index Per Article: 25.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
PURPOSE To compare, by performing a meta-analysis, the accuracies of ultrasonography (US), magnetic resonance (MR) imaging, scintigraphy, computed tomography (CT), and positron emission tomography (PET) in the diagnosis of inflammatory bowel disease (IBD). MATERIALS AND METHODS MEDLINE, EMBASE, CINAHL, and Cochrane databases were searched for studies on the accuracy of US, MR imaging, scintigraphy, CT, and PET, as compared with a predefined reference standard, in the diagnosis of IBD. Sensitivity and specificity estimates were calculated on per-patient and per-bowel-segment bases by using a bivariate random-effects model. RESULTS Thirty-three studies, from a search that yielded 1406 articles, were included in the final analysis. Mean sensitivity estimates for the diagnosis of IBD on a per-patient basis were high and not significantly different among the imaging modalities (89.7%, 93.0%, 87.8%, and 84.3% for US, MR imaging, scintigraphy, and CT, respectively). Mean per-patient specificity estimates were 95.6% for US, 92.8% for MR imaging, 84.5% for scintigraphy, and 95.1% for CT; the only significant difference in values was that between scintigraphy and US (P = .009). Mean per-bowel-segment sensitivity estimates were lower: 73.5% for US, 70.4% for MR imaging, 77.3% for scintigraphy, and 67.4% for CT. Mean per-bowel-segment specificity estimates were 92.9% for US, 94.0% for MR imaging, 90.3% for scintigraphy, and 90.2% for CT. CT proved to be significantly less sensitive and specific compared with scintigraphy (P = .006) and MR imaging (P = .037) CONCLUSION No significant differences in diagnostic accuracy among the imaging techniques were observed. Because patients with IBD often need frequent reevaluation of disease status, use of a diagnostic modality that does not involve the use of ionizing radiation is preferable.
Collapse
|
17
|
Abstract
The investigation of small bowel morphology is often mandatory in many patients with Crohn’s disease. Traditional radiological techniques (small bowel enteroclysis and small bowel follow-through) have long been the only suitable methods for this purpose. In recent years, several alternative imaging techniques have been proposed. To review the most recent advances in imaging studies of the small bowel, with particular reference to their possible application in Crohn’s disease, we conducted a complete review of the most important studies in which traditional and newer imaging methods were performed and compared in patients with Crohn’s disease. Several radiological and endoscopic techniques are now available for the study of the small bowel; each of them is characterized by a distinct profile of favourable and unfavourable features. In some cases, they may also be used as complementary rather than alternative techniques. In everyday practice, the choice of the technique to be used stands upon its availability and a careful evaluation of diagnostic accuracy, clinical usefulness, safety and cost. The recent development of innovative imaging techniques has opened a new and exciting area in the exploration of the small bowel in Crohn’s disease patients.
Collapse
|
18
|
Abstract
BACKGROUND AND AIMS Postsurgical recurrence (PSR) is common in patients with Crohn's disease (CD) who have undergone surgery. Endoscopy is crucial for the diagnosis of PSR, showing also high prognostic value. Bowel sonography (BS) is accurate for CD diagnosis, but its role in PSR detection and grading has been poorly investigated. The aim of this study was to evaluate the diagnostic accuracy of BS compared to endoscopy in the detection of PSR. MATERIALS AND METHODS Between March 2002 and October 2005, to gain evidence of possible PSR, we prospectively performed endoscopy and BS in 45 CD patients who had undergone previous bowel resection. Endoscopy and BS were carried out 1 year after surgery, with diagnosis and grading of PSR made in accordance with Rutgeerts. BS was considered suggestive for PSR in the presence of bowel wall thickness (BWT)>3 mm. Also, an ROC curve was constructed to define the best cutoff value for BWT to differentiate mild from severe PSR (grade 1-2 vs 3-4 of Rutgeerts). RESULTS Of the 45 patients with CD, 24 showed endoscopic evidence of PSR (53%). Severe endoscopic PSR was present in 16 patients (66%). Sensitivity, specificity, and positive and negative predictive values of BS were 79%, 95%, 95%, and 80%, respectively, with a sensitivity of 93% for severe PSR. On the ROC curve, a BWT>5 mm showed sensitivity, specificity, and positive and negative predictive values of 94%, 100%, 100%, and 96%, respectively, in differentiating mild from severe PSR, in remarkable agreement with endoscopy (kappa=0.90). CONCLUSIONS BS shows good sensitivity and high specificity for the diagnosis of PSR in CD, with a BWT>5 mm being strongly indicative of severe endoscopic PSR. Hence, BS could replace endoscopy for the diagnosis and grading of PSR in patients who comply poorly with the endoscopic examination.
Collapse
|
19
|
Abstract
Most published studies have found bowel ultrasound to be a useful tool in the management of Crohn's disease. Indeed, it has been successfully used as the imaging technique of choice in screening patients with clinically suspected Crohn's disease. In these patients, bowel ultrasound, which is well accepted by patients, non-invasive and of low cost, may be the first diagnostic tool employed for young patients and can be used in the preliminary diagnostic work-up prior to further invasive tests. The most important application of bowel ultrasound is, however, in the follow-up of patients already diagnosed with Crohn's disease, in whom it may be useful to assess the site and extent of the lesions and to ensure the early detection of intra-abdominal complications, particularly abscesses and strictures. In this regard, improving the ultrasound assessment of intramural blood flow by means of colour power-Doppler ultrasonography and intravenous contrast agents may help to differentiate fibrotic and inflammatory strictures, and to discriminate inflammatory masses from intra-abdominal abscesses. Despite several attempts to correlate ultrasound findings with clinical and biochemical activity, there are as yet no convincing data on the usefulness of ultrasound in assessing the activity of Crohn's disease. In contrast, preliminary results are in agreement regarding the usefulness of ultrasound in the assessment of postoperative recurrence and in monitoring the outcome of the disease following surgery. In fact, the persistence of a thickened bowel wall or increased high bowel wall thickening at ultrasound following surgery has been identified as an index of early surgical recurrence. How these data may be usefully employed in the management of individuals with Crohn's disease needs to be investigated in further studies.
Collapse
|
20
|
Targeting mucosal addressin cellular adhesion molecule (MAdCAM)-1 to noninvasively image experimental Crohn's disease. Gastroenterology 2006; 130:8-16. [PMID: 16401463 DOI: 10.1053/j.gastro.2005.11.009] [Citation(s) in RCA: 93] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/18/2005] [Accepted: 11/02/2005] [Indexed: 12/20/2022]
Abstract
BACKGROUND & AIMS Inflammatory bowel disease (IBD) is the second most common chronic inflammatory disorder worldwide; however, a noninvasive means of accurately assessing the severity and extent of intestinal inflammation is currently not available. The aim of the present study was to develop a noninvasive imaging modality to detect and evaluate ileitis in SAMP1/YitFc (SAMP) mice. METHODS An image-enhancing ultrasound (US) contrast agent, consisting of encapsulated gaseous microbubbles (MB), was developed specifically to bind mucosal addressin cellular adhesion molecule-1 (MAdCAM-1), a mucosal-restricted addressin up-regulated during gut inflammation. MAdCAM-1-targeted MB (MB(M)) were tested for binding specificity on MAdCAM-1 protein and tumor necrosis factor (TNF)-stimulated SVEC4-10 endothelial cells using an in vitro flow chamber assay and for their ability to detect and quantify ileitis by intravital microscopy and transabdominal US. RESULTS Under in vitro flow conditions, a 100-fold increase in MB(M) binding was observed on MAdCAM-1 protein compared with nonspecific MB (P < .001). TNF-stimulated endothelial cells bound significantly more MB(M) vs nonspecific MB (P < .001), which was abrogated after preincubation with anti-MAdCAM-1 antibodies (P < .001). In vivo, MB(M) specifically accumulated in focal areas of ileal inflammation and produced stronger acoustic echoes, measured by average video intensity, in SAMP vs uninflamed AKR mice (P < .001) or SAMP given nonspecific MB (P < .001). MB(M)-specific video intensity showed a strong positive correlation with total ileal inflammatory scores (R2 = 0.92). CONCLUSIONS We have developed a novel intravascular US contrast agent targeting MAdCAM-1 that specifically detects and quantifies intestinal inflammation in experimental ileitis, providing the potential for a reliable, noninvasive means to diagnose and monitor disease in patients with IBD.
Collapse
|
21
|
Abstract
PURPOSE To evaluate the accuracy of ultrasonography (US) in the detection of Crohn disease in adults by systematically reviewing both cohort studies (those including patients whose clinical characteristics were consistent with those caused by an inflammatory bowel disease) and case-control studies (those in which patients with Crohn disease were compared with patients with other bowel diseases or healthy control subjects). MATERIALS AND METHODS The MEDLINE, EMBASE, and Cochrane Library databases were used to retrieve all the cross-sectional studies that assessed the diagnostic accuracy of US against that of one of several predefined reference standards (ie, radiologic, endoscopic, or histologic findings). The studies that fulfilled the inclusion criteria were identified, and their methodological quality was evaluated. Of the 2860 primary studies identified, two case-control and five cohort series fulfilled the inclusion criteria. Statistical analysis was performed by using the summary receiver operating characteristic (SROC) model. RESULTS The ranges of US sensitivity and specificity for the diagnosis of Crohn disease reported for the included series were 75%-94% and 67%-100%, respectively; the heterogeneity of these values prevented the calculation of a cumulative value. The SROC curve revealed a clear cutoff effect that depended on the chosen bowel wall thickness threshold. Sensitivity and specificity of 88% and 93%, respectively, were achieved when a bowel wall thickness threshold greater than 3 mm was used, and sensitivity and specificity of 75% and 97%, respectively, were achieved when a threshold greater than 4 mm was used. CONCLUSION US examination seems appropriate for confirming or excluding Crohn disease as a diagnosis in a clinical context characterized by a pretest probability of Crohn disease that ranges from 12% to about 60%. In particular, for Crohn disease limited to the ileum, US may represent a valid alternative to the small-bowel series, while for colonic involvement US may be useful in ruling out the diagnosis.
Collapse
|
22
|
Noninvasive diagnosis of small bowel Crohn's disease: combined use of bowel sonography and Tc-99m-HMPAO leukocyte scintigraphy. Inflamm Bowel Dis 2005; 11:376-82. [PMID: 15803028 DOI: 10.1097/01.mib.0000164020.65106.84] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/09/2022]
Abstract
BACKGROUND Crohn's disease (CD) is frequently localized in the small bowel, with the diagnosis of disease and the assessment of its extension made by ileo-colonoscopy (IC) and small bowel enteroclysis (SBE). Transabdominal bowel sonography (BS) and Tc-99m-HMPAO leukocyte scintigraphy (LS) are increasingly used for the diagnosis of CD because of their minimal invasiveness, reproducibility, and acceptable costs. METHODS From March 2000 to July 2003, we performed IC, SBE, BS, and LS in 84 patients with either suspected or known small bowel CD. RESULTS Small bowel CD was present in 50 patients, whereas the other 34 patients received a different diagnosis. Sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy were, respectively, 98%, 97%, 98%, 97%, and 0.97 for SBE; 92%, 97%, 98%, 88%, and 0.94 for BS; and 90%, 93%, 96%, 85%, and 0.92 for LS. In addition, the combined use of BS and LS led to overall sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy of 100%, 93%, 96%, 100%, and 0.97, respectively. BS showed a fair concordance with SBE in terms of location (k = 0.71) and a correlation with the extension of the disease (r = 0.67, P < 0.001). LS showed a concordance with SBE with regard to location in about one-half the population (k = 0.54), whereas it was less effective than SBE in defining disease extension. CONCLUSIONS BS and LS are 2 accurate techniques for the diagnosis of small bowel CD, and their combined use can be recommended as an early diagnostic approach to patients in which the disease is suspected. SBE remains the best procedure for the definition of the location and extension of the disease.
Collapse
|
23
|
Abstract
BACKGROUND Radiology and transabdominal ultrasonography (TUS) are used in the evaluation of the small bowel; however, the former technique is limited by radiation exposure, and the latter by its inability to visualize the entire small bowel. AIM To evaluate the diagnostic accuracy of small intestine contrast ultrasonography (SICUS) to assess the presence, number, site, and extension of small bowel lesions. SUBJECTS AND METHODS TUS, SICUS, and small bowel follow-through (SBFT) were performed in 148 consecutive patients (78 women; age range, 12 to 89 yr), 91 with undiagnosed conditions, and 57 with previously diagnosed Crohn's disease (CD). RESULTS In the undiagnosed patients, the sensitivity and specificity of TUS and SICUS were 57% and 100%, and 94.3% and 98%, respectively. In the CD patients, the sensitivity of TUS and SICUS was 87.3% and 98%, respectively. In comparison with SBFT, the extension of lesions was correctly assessed with SICUS and greatly underestimated with TUS. The concordance index between SBFT and SICUS for the number and site of lesions was 1 and 1 (P < 0.001), respectively, in undiagnosed patients, and 0.81 and 0.83 (P < 0.001), respectively, in CD patients. Between SBFT and TUS, the concordance index was 0.28 and 0.27 (not significant), respectively, in undiagnosed patients, and 0.28 and 0.31 (not significant), respectively, in CD patients. CONCLUSIONS The diagnostic accuracy of SICUS is comparable to that of a radiologic examination, and is superior to that of TUS in detecting the presence, number, extension, and sites of small bowel lesions. These findings support the use of noninvasive SICUS for an initial investigation when small bowel disease is suspected and in the follow-up of CD patients.
Collapse
|
24
|
Abstract
OBJECTIVES Abdominal ultrasound can assess the extent and localization of Crohn's disease, and an increased bowel wall thickness is the most common finding. Our aim was to correlate bowel wall thickness at ultrasound, with the risk of short-term surgical outcome in patients with Crohn's disease. MATERIALS AND METHODS From 1997 to 2000 we performed ultrasound in 174 consecutive patients with Crohn's disease. Surgical operations were recorded over a 1-yr follow-up. Logistic regression analysis was performed to identify clinical and ultrasound risk factors for surgery. RESULTS Fifty-two patients underwent surgery within 1 yr. Indication for surgery was strictures in most of the cases. Median bowel wall thickness was higher in patients with surgery (8 mm) than those without surgery (6 mm) (p < 0.0001). A receiver operating characteristic (ROC) curve was constructed taking into account bowel wall thickness for selecting patients with a high risk of surgery. The optimized cut-off for equally important sensitivity and specificity was calculated at 7.008 mm. The binary regression analysis showed that CDAI > 150, absence of previous surgery, stricturing-penetrating pattern, the presence of intestinal complications, and intestinal wall thickness >7 mm were associated with an increased risk of surgery. Patients with intestinal wall thickness >7 mm at ultrasound had the highest risk (OR: 19.521, 95% CI: 5.362-71.065). CONCLUSIONS Data suggest that bowel wall thickness >7 mm at ultrasound is a risk factor for intestinal resection over a short period of time. Routine use of abdominal ultrasound during evaluation of patients with Crohn's disease may identify a subgroup that is at high risk for surgery. (Am J Gastroenterol 2004;99:1-7)
Collapse
|
25
|
Abstract
Technological advancement of ultrasound (US) equipments and understanding of bowel appearances with high resolution US during the last decade has led to consideration of this imaging procedure as an important tool for inflammatory bowel diseases assessment. In particular, Crohn's disease (CD) for its pathologic characteristics (that is, inflammatory infiltration of the entire bowel wall with possible extension to the surrounding mesentery) is the disease entity which has mainly taken advantage from this non-invasive, radiation-free technique. Beside correctly defining anatomic location and extension of CD lesions within the bowel in the majority of cases, US also shows perigut abnormalities and may demonstrate complications such as fistulas and abscesses. With the help of Power Doppler function, some additional information may be obtained about the local activity of the disease which is particularly useful in the presence of strictures. New US technologies (such as those using intravenous bolus contrast agents or oral nonabsorbable anechoic solutions) may further improve diagnostic capability of US in this context, thus probably revolutioning the diagnostic approach to this disease in the near future, particularly during follow-up in CD of the small bowel.
Collapse
|
26
|
Abstract
Recent advances of cross sectional imaging allow optimal evaluation of the small bowel. This chapter will detail technical considerations and emphasize the role of imaging in the evaluation of the most common diseases of the small bowel.
Collapse
|
27
|
Abstract
AIM Bowel wall thickening on transabdominal ultrasound scanning (USS) correlates well with Crohn's disease (CD) activity. However, the role of USS in the assessment of CD has not been fully defined. This study compared USS and barium follow-through (BaFT) in the assessment of CD. METHODS A retrospective case series was undertaken of 24 children with CD who underwent USS and BaFT during the same period of clinical disease activity. RESULTS For terminal ileum abnormality, all 13 cases with abnormal USS had abnormality on BaFT. USS did not detect five cases with affected terminal ileum and two cases with isolated proximal small-bowel CD. CONCLUSION BaFT is a more sensitive indicator of small-bowel CD than USS. USS has good positive predictive value of distal small-bowel CD, but BaFT should be performed in the presence of a normal USS where there is strong clinical evidence of CD.
Collapse
|
28
|
Detection of ileocecal Crohn's disease using ultrasound as the primary imaging modality. Eur Radiol 2004; 14:778-82. [PMID: 14760505 DOI: 10.1007/s00330-003-2204-1] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2003] [Revised: 07/31/2003] [Accepted: 12/01/2003] [Indexed: 12/15/2022]
Abstract
At our hospital ultrasound (US) is used as an initial screening procedure in all patients with abdominal symptoms. The purpose of this study was to assess the effect of this policy on the detection of ileocecal Crohn's disease. We retrospectively studied all patients with a new diagnosis of ileocecal Crohn's disease from our institute over the period 1990-2001. The final diagnosis was based on clinical follow-up and pathological, surgical, US, and other radiological findings. We noted who referred the patient to the radiology department, what the initial clinical presumption was, and what the first imaging study was. US diagnoses were determined from the initial US report and US findings were registered from the images. There were a total of 47 patients (20 men, 27 women) with a mean age of 30 years and a median age of 27 years (range 14-75 years). In all patients the initial imaging study was an abdominal US. Using US, a confident diagnosis of ileocecal Crohn's disease was made in 35 of the 47 patients, Crohn's disease was suggested among the differential diagnosis in 10, and an incorrect diagnosis was made in 2 patients. In 28 of 47 patients, the referring physician did not consider Crohn's disease when requesting the initial US examination. In eight patients with appendicitis-like symptoms, the US findings strongly influenced the decision to refrain from operation at that point in time. US, when used as a low-threshold diagnostic procedure, is a reliable and noninvasive means for making an early diagnosis of ileocecal Crohn's disease in patients who present with atypical symptoms. It may prevent both unnecessary therapeutic delay as well as unnecessary surgery.
Collapse
|
29
|
Role of early ultrasound in detecting inflammatory intestinal disorders and identifying their anatomical location within the bowel. Aliment Pharmacol Ther 2003; 18:1009-16. [PMID: 14616167 DOI: 10.1046/j.1365-2036.2003.01796.x] [Citation(s) in RCA: 125] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
BACKGROUND Although bowel ultrasound is a widely accepted diagnostic tool in bowel diseases, its value as the primary imaging procedure in patients with symptoms/signs suggestive of inflammatory bowel disorders is still unclear. AIM To investigate the accuracy of bowel ultrasound compared with barium X-ray studies, computed tomography, endoscopy and bowel surgery in the initial assessment of inflammatory bowel disorders. METHODS Four hundred and eighty-seven patients hospitalized consecutively for symptoms or signs suggestive of a bowel disorder between December 1999 and March 2002 were initially enrolled in the study. All patients underwent bowel ultrasound as the first imaging procedure within 36 h of admission; radiographic evaluations, endoscopy and/or surgery were then performed as appropriate and the results of these investigations were used as the gold standard. RESULTS Three hundred and thirty-six patients had pathological findings of the bowel detectable at ultrasound as the final diagnosis. The main organic disorders found were Crohn's disease (56%), ulcerative/indeterminate colitis (30%), bowel tumours (5%), appendicitis/diverticulitis (2%) and other inflammatory conditions (8%). The overall sensitivity and specificity of bowel ultrasound were 85% and 95%, respectively, whereas the positive and negative predictive values were 98% and 75%, respectively. Comparisons of ultrasound with X-ray or endoscopic results by disease localization showed that the diagnostic performance of ultrasound was higher for inflammatory conditions of the ileum and sigmoid/descending colon (sensitivity of 92% and 87%, respectively), whereas abnormalities localized in the rectum, duodenum and proximal jejunum were often missed by ultrasound. CONCLUSIONS In expert hands, bowel ultrasound is highly predictive of inflammatory disease localized in the ileum or colon, and may well be used as the primary imaging method when Crohn's disease or ulcerative colitis is suspected on a clinical basis.
Collapse
|
30
|
Abstract
GOALS AND BACKGROUND Fibrosing colonopathy causing severe thickening of the colon wall was recently described in cystic fibrosis (CF). Since it has been suspected that subclinical colon-wall thickening is a common feature in CF patients, bowel-wall thickness was measured in a series of patients and compared with controls. Additionally, possible clinical factors influencing wall thickness were investigated. STUDY In 83 CF patients and 31 controls transabdominal ultrasound was performed in the terminal ileum, cecum, ascending and descending colon. The relation of the measured wall thickness to age, sex, pancreatic enzyme intake, and intestinal diseases was analyzed. RESULTS In controls, mean wall thickness depending on gut region was 1.1 to 1.3 mm (SD 0.19-0.23). In CF patients, no evidence of severe thickening or stricture was found, but wall thickness was significantly higher than in controls in all measured regions (1.5-1.6 mm; SD 0.31-0.41). Patients with meconium ileus and distal intestinal obstruction syndrome had significantly increased thickness of the terminal ileum compared with patients without these complications. Neither the intake of high-strength enzymes nor enzyme dosage, age or sex were associated with wall thickness. CONCLUSIONS We found no evidence that a subclinical stage of fibrosing colonopathy is prevalent among the CF patients. Slightly thickened gut walls in CF can be interpreted as an expression of glandular dysfunction in the CF intestine.
Collapse
|
31
|
Ultrasonographic findings correspond to clinical, endoscopic, and histologic findings in inflammatory bowel disease and other enterocolitides. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2002; 21:375-382. [PMID: 11934094 DOI: 10.7863/jum.2002.21.4.375] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
OBJECTIVE To compare results obtained by abdominal ultrasonography with clinical findings, including endoscopic and histologic findings, to evaluate the location and activity of inflammatory bowel disease, including disease controls in children. METHODS Ninety-two ultrasonographic scans and 41 colonoscopic examinations with biopsies were performed in 78 patients (1 month to 17.8 years of age) with Crohn's disease (n = 26), ulcerative colitis (n = 21), inflammatory bowel disease of indeterminate type (n = 2), and disease controls (other intestinal disorders, including infectious and ischemic lesions; n = 29). Laboratory parameters for inflammatory bowel disease were determined, and disease activity was assessed by a combination of clinical and laboratory data. Bowel wall thickness and echo texture were recorded in a standardized way by ultrasonography and compared with endoscopic and histologic findings in a segment-by-segment comparison. RESULTS Sensitivity and specificity of ultrasonography in detecting patients with severe macroscopic lesions depicted on endoscopy were 77% and 83%, respectively. Sensitivity and specificity of ultrasonography in detecting patients with severe histologic inflammation were 75% and 82%. There was a statistically significant correlation between maximal bowel wall thickness and disease activity score (P < .01). CONCLUSIONS Abdominal ultrasonography may be helpful in evaluating the location, severity, and inflammatory activity of inflammatory bowel disease in children and young adults.
Collapse
|
32
|
Small intestine contrast ultrasonography (SICUS) in the diagnosis of small intestine lesions. ULTRASOUND IN MEDICINE & BIOLOGY 2001; 27:335-341. [PMID: 11369118 DOI: 10.1016/s0301-5629(00)00356-2] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
After the ingestion of iso-osmolar polyethylene glycol solution, the small bowel can be visualized on ultrasonography. The aim of this study was to assess sensitivity and specificity of SICUS in diagnosis of small bowel lesions. A total of 53 consecutive patients with suspected intestinal pathology underwent a diagnostic workup, including a small bowel follow-through and SICUS performed by independent operators. The sonologist was unaware of the clinical data. Diagnostic sensitivity and specificity were assessed using radiologic findings. Diagnostic sensitivity of SICUS was 100%, with a specificity of 97%. The concordance index was 0.956 (p < 0.003, kappa statistics) and the conformity between SICUS and radiology was 1. The diagnostic accuracy of SICUS to detect small bowel lesions is comparable to that of small bowel follow-through. Results of this study support the use of noninvasive, widely available, inexpensive, and nondemanding SICUS as an initial investigation in patients with suspected small bowel disease.
Collapse
|
33
|
Transabdominal ultrasonography of the small bowel after oral administration of a non-absorbable anechoic solution: comparison with barium enteroclysis. Clin Radiol 2001; 56:225-30. [PMID: 11247701 DOI: 10.1053/crad.2000.0625] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
AIM The aim of this study was to determine if oral administration of a non-absorbable anechoic solution conveys any benefit during abdominal ultrasound (US), with special reference to its accuracy. MATERIALS AND METHODS Fifty-three adult out-patients scheduled for small bowel barium enema (SBE) were included. The day before SBE all patients underwent abdominal US before and after oral administration of an isotonic non-absorbable electrolyte solution containing polyethylene glycol (PEG-ELS). Sensitivity and specificity were evaluated using SBE as a gold standard. RESULTS After ingestion of PEG-ELS satisfactory distension of the intestinal lumen was obtained (11-25 mm) with sequential visualization of jejunoileal loops in 30.9 +/- 17.3 min. In 15 out of 53 cases both US and SBE showed bowel changes characteristic of Crohn's disease. In three out of 53 cases both US and SBE showed neoplasms. In one out of 53 cases US was negative, SBE positive for local nodularity and ulcerations typical of Crohn's disease. In one out of 53 cases US was negative, SBE positive for macronodularity consistent with coeliac disease. In five out of 53 cases US was negative, while SBE was positive for mininodularity expressive of lymphoid hyperplasia. In 28 out of 53 cases both examinations were negative. CONCLUSION PEG-ELS administration allows a thorough US investigation of the small bowel, with fair sensitivity (72%) and excellent specificity (100%). False negative findings are mainly due to lymphoid hyperplasia, a feature of uncertain significance in adults.
Collapse
|
34
|
Abstract
OBJECTIVE The purpose of this work is to prospectively evaluate high resolution ultrasonography with graded compression in the ability to detect Crohn's disease of the small bowel (CDSB) together with its complications and activity signs, compared with enteroclysis, CT and immunoscintigraphy in the mirror of the final diagnosis. METHODS AND MATERIAL In a series of 73 consecutive patients, who were referred for enteroclysis with suspected Crohn's disease of the small bowel computed tomography (CT), ultrasound (US), immunoscintigraphy with 99mTc labeled monoclonal antigranulocyte antibody (AGAb) examinations were performed within 10 days from each other. For the final evaluation the diagnosis of CDSB was based on combination of clinical and enteroclysis findings (73 cases) and in 17 cases additional surgical and pathological data were available. The results of other modalities were blinded to the radiologists performing and reading out the exams. The diagnostic values of each modality was assessed also in those 18 patients, who had early Crohn's disease. In the group of 43 patients with proven CDSB who had all the four imaging modalities, the modalities were compared in their ability to demonstrate various pathological conditions related to CD. Increased (>500 ml/min) flow measured by Doppler US in the superior mesenteric artery and increased color signs in the gut wall seen by power Doppler sonography were compared to CDAI. RESULTS Of the 73 patients the combination of enteroclysis and clinical tests demonstrated CDSB in 47. The sensitivity, specificity and accuracy of ultrasound were 88.4, 93.3 and 90.4%, respectively. Enteroclysis was the most accurate method. CT was more sensitive than US, but less specific. The accuracy of US, CT and scintigraphy were similar. In the group of 18 patients, who had early CDSB, the sensitivity of US decreased to only 67%, CT and scintigraphy had higher values. Intra- and perimural abscesses, and sinus tracts were also more frequently visualized by US, especially if they were small. US was superior than CT in detecting stenoses and skip lesions, but inferior to enteroclysis. US and CT detected more fistulas, than enteroclysis. Compared to CT, US detected more cases with mesenteric lymphadenopathy, equal cases with abscesses and free peritoneal fluids. In detecting mesenteric inflammatory proliferation CT, and in detecting colonic involvement CT and immunoscintigraphy were slightly superior than graded compression US. Patterns of mural stratification detected by ultrasound correlated well with the enteroclysis severity stages. There was only 59% agreement between increased superior mesenteric artery flow detected by Doppler sonography and CDAI, and 60.5% agreement between increased number of Color pixels in the gut wall measured by power Doppler and increased CDAI. CONCLUSION High resolution graded compression sonography is a valuable tool for detecting small intestinal Crohn's disease. It has similar diagnostic values as CT. However in early disease the sensitivity substantially decreases. In known Crohn's disease for following disease course, evaluating relapses and extramural manifestations US is an excellent tool. Doppler and Power Doppler activity measurements do not correlate well with the more widespread clinical activity index.
Collapse
|
35
|
Abstract
The purpose of this review is to highlight new developments during the past year regarding diagnosis and clinical features of inflammatory bowel disease. Endoscopy remains the cornerstone for diagnosis and evaluation of ileocolonic inflammatory bowel disease. In ulcerative colitis, recent studies have challenged the concept of a continuous and homogeneous inflammatory process with constant rectal involvement: patchy inflammation and rectal sparing were reported in treated ulcerative colitis, and frequent cecum and appendiceal orifice skip lesions were confirmed. Cross-sectional imaging techniques usefully complement endoscopy by assessing whole-bowel thickness and detecting abscesses and fistulae. Furthermore, echo Doppler ultrasound is able to measure mesenteric blood flow, which is increased in active inflammatory bowel disease and seems to parallel inflammatory disease activity. Osteopenia, which affects approximately half of patients with inflammatory bowel disease, can be detected by dual-energy x-ray absorptiometry and prevented. Hyperhomocysteinemia, a predisposing factor for thrombosis, seems to be more frequent in inflammatory bowel disease, and can be corrected by folate supplementation. The concept of an aggressive, penetrating form of Crohn disease with early postoperative recurrence as opposed to a more indolent, nonpenetrating form of the disease, with later recurrence, was recently challenged. The most significant predictor of the risk of malignancy in inflammatory bowel disease remains the presence of dysplasia in colonic biopsy specimens. A dysplastic polypoid lesion or mass is a strong predictor of cancer but should be distinguished from the dysplasia inherent in a coincident sporadic adenoma.
Collapse
|
36
|
|
37
|
Abstract
OBJECTIVE Ultrasonography is a valid tool in the diagnosis of Crohn's disease, but its sensitivity, specificity, and overall accuracy in the diagnosis of postoperative recurrence are still not well established. The aim of this study was to evaluate the accuracy of ultrasonography compared with endoscopy in the diagnosis of postoperative recurrence of Crohn's disease. METHODS Forty-seven patients resected for Crohn's ileitis were studied by ultrasonography and colonoscopy to detect possible recurrence of the disease; 10 patients operated on for cancer of the right colon were used as controls. Six patients with Crohn's disease were excluded from the study because of failure to endoscopically reach the anastomosis; the remaining 41 patients had both ultrasonography and colonoscopy over a period of 14 days. Sonographic recurrence was defined as the presence of >5 mm thickness of the ileal wall. RESULTS Sensitivity, specificity, and overall accuracy of ultrasonography in diagnosis of postoperative recurrence were 81%, 86%, and 83% respectively. Positive predictive value was 96% and negative predictive value was 57%. CONCLUSION This study is the first to assess the role of ultrasonography in comparison with endoscopy in detecting Crohn's disease recurrence after surgery. Our data suggest that ultrasonography should be used first in the case of clinical suspicion of Crohn's disease recurrence, reserving ileocolonoscopy for negative or uncertain cases.
Collapse
|
38
|
Abstract
This chapter reviews the current state of imaging in Crohn's disease. Imaging plays an important role in the diagnosis and management of Crohn's disease. Imaging is complementary to the clinical assessment of the patient and other investigations including endoscopy. The choice of imaging modality depends on the clinical circumstances and local availability of resources and skills. Close co-operation between clinicians and radiologists is important. Barium radiology remains important. Magnetic resonance imaging (MRI) and ultrasound (US) should get special consideration because of the lack of ionizing radiation. MRI is particularly good at demonstrating the perianal complication of Crohn's disease. Computer tomography (CT) and US can be used for image-guided drainage of abscesses.
Collapse
|
39
|
|