1
|
Huang L, Zhou Y, Hu X, Yang Z. Emerging Combination of Hydrogel and Electrochemical Biosensors. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2025; 21:e2409711. [PMID: 39679847 DOI: 10.1002/smll.202409711] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2024] [Revised: 12/05/2024] [Indexed: 12/17/2024]
Abstract
Electrochemical sensors are among the most promising technologies for biomarker research, with outstanding sensitivity, selectivity, and rapid response capabilities that make them important in medical diagnostics and prognosis. Recently, hydrogels have gained attention in the domain of electrochemical biosensors because of their superior biocompatibility, excellent adhesion, and ability to form conformal contact with diverse surfaces. These features provide distinct advantages, particularly in the advancement of wearable biosensors. This review examines the contemporary utilization of hydrogels in electrochemical sensing, explores strategies for optimization and prospective development trajectories, and highlights their distinctive advantages. The objective is to provide an exhaustive overview of the foundational principles of electrochemical sensing systems, analyze the compatibility of hydrogel properties with electrochemical methodologies, and propose potential healthcare applications to further illustrate their applicability. Despite significant advances in the development of hydrogel-based electrochemical biosensors, challenges persist, such as improving material fatigue resistance, interfacial adhesion, and maintaining balanced water content across various environments. Overall, hydrogels have immense potential in flexible biosensors and provide exciting opportunities. However, resolving the current obstacles will necessitate additional research and development efforts.
Collapse
Affiliation(s)
- Lingting Huang
- Strait Institute of Flexible Electronics (SIFE, Future Technologies), Fujian Key Laboratory of Flexible Electronics, Fujian Normal University and Strait Laboratory of Flexible Electronics (SLoFE), Fuzhou, 350117, China
| | - Yuyang Zhou
- Strait Institute of Flexible Electronics (SIFE, Future Technologies), Fujian Key Laboratory of Flexible Electronics, Fujian Normal University and Strait Laboratory of Flexible Electronics (SLoFE), Fuzhou, 350117, China
| | - Xiaoming Hu
- Strait Institute of Flexible Electronics (SIFE, Future Technologies), Fujian Key Laboratory of Flexible Electronics, Fujian Normal University and Strait Laboratory of Flexible Electronics (SLoFE), Fuzhou, 350117, China
- School of Materials Science and Engineering, East China Jiaotong University, Nanchang, 330013, China
| | - Zhen Yang
- Strait Institute of Flexible Electronics (SIFE, Future Technologies), Fujian Key Laboratory of Flexible Electronics, Fujian Normal University and Strait Laboratory of Flexible Electronics (SLoFE), Fuzhou, 350117, China
| |
Collapse
|
2
|
Zhang Y, Zhu J, Zhao J, Wang X, Wei T, Gao T. A single-microbe living bioelectronic sensor for intracellular amperometric analysis. Biosens Bioelectron 2024; 265:116648. [PMID: 39178718 DOI: 10.1016/j.bios.2024.116648] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2024] [Revised: 07/26/2024] [Accepted: 08/07/2024] [Indexed: 08/26/2024]
Abstract
Subcellularly amperometric analysis in situ is crucial for understanding intracellular redox biochemistry and subcellular heterogeneity. Unfortunately, the ultra-small size and complex microenvironment inside the cell pose a great challenge to achieve this goal. To address the challenge, a minimized living microbial sensor has been fabricated in this work for amperometric analysis. Here, by fabricating the dimidiate microelectrode as the working electrode, while fitting a living electroactive bacterium (EAB) as the transducer, outward extracellular electron transfer (EET) of the sensory EAB is correlated with the concentration of lactic acid, which is electrochemically recorded and thus displays an electrical signal output for detection. In specific, the S. oneidensis modified dimidiate microelectrode (S.O.@GNE-NPE) acts as an integrated electroanalytical device to generate the electrical signal in situ. The established microcircuit provides unprecedented precision and sensitivity, contributing to subcellular amperometric measurement. The microbial sensor shows a linear response in the concentration range of 0-60 mM, with a limit of detection (LOD) at 0.3 mM. The microsensor also demonstrates good selectivity against interferences. Additionally, intracellular analysis of lactic acid provides direct evidence of enhanced lactic metabolism in cancer cells as a result of "Warburg Effect". This work shows an example of nano-, bio- and electric technologies that have been integrated on the EAB-modified dimidiate microelectrode, and achieves intracellular biosensing application through such integration. It may give a new strategy on the combination of micro/nanotechnologies with sensory EAB for the necessary development of bioelectronic devices.
Collapse
Affiliation(s)
- Yixin Zhang
- Jiangsu Key Laboratory for Molecular and Medical Biotechnology, College of Life Sciences, Nanjing Normal University, Nanjing, 210023, China
| | - Jin Zhu
- Jiangsu Key Laboratory for Molecular and Medical Biotechnology, College of Life Sciences, Nanjing Normal University, Nanjing, 210023, China
| | - Jinming Zhao
- Jiangsu Key Laboratory for Molecular and Medical Biotechnology, College of Life Sciences, Nanjing Normal University, Nanjing, 210023, China
| | - Xiaojun Wang
- Jiangsu Key Laboratory for Molecular and Medical Biotechnology, College of Life Sciences, Nanjing Normal University, Nanjing, 210023, China
| | - Tianxiang Wei
- School of Environment, Nanjing Normal University, Nanjing, 210023, China
| | - Tao Gao
- Jiangsu Key Laboratory for Molecular and Medical Biotechnology, College of Life Sciences, Nanjing Normal University, Nanjing, 210023, China.
| |
Collapse
|
3
|
Plekhanova YV, Reshetilov AN. Microbial Biosensors for the Determination of Pesticides. JOURNAL OF ANALYTICAL CHEMISTRY 2019. [DOI: 10.1134/s1061934819120098] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
4
|
Antonacci A, Scognamiglio V. Biotechnological Advances in the Design of Algae-Based Biosensors. Trends Biotechnol 2019; 38:334-347. [PMID: 31706693 DOI: 10.1016/j.tibtech.2019.10.005] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2019] [Revised: 09/25/2019] [Accepted: 10/09/2019] [Indexed: 01/14/2023]
Abstract
In addition to their use in biomass production and bioremediation, algae have been extensively exploited in biosensing applications. Algae-based biosensors have demonstrated potential for sensitive, sustainable, and multiplexed detection of analytes of agroenvironmental and security interest. Their advantages include the availability of different algal bioreceptors including whole cells and their photosynthetic subcomponents, their potential to be integrated into dual transduction miniaturized devices, and the opportunity for continuous environmental monitoring. Despite obstacles including limited stability and selectivity, algae-based biosensing is a realistic prospect that has some recent effective applications. Strategic exploitation of cutting-edge technologies including materials science, nanotechnology, microfluidics, and genome editing will help to achieve the full potential of algae-based sensors.
Collapse
Affiliation(s)
- Amina Antonacci
- Institute of Crystallography (IC-CNR), Department of Chemical Sciences and Materials Technologies, Via Salaria km 29.300, 00015 Monterotondo, Italy.
| | - Viviana Scognamiglio
- Institute of Crystallography (IC-CNR), Department of Chemical Sciences and Materials Technologies, Via Salaria km 29.300, 00015 Monterotondo, Italy.
| |
Collapse
|
5
|
Balbaied T, Moore E. Overview of Optical and Electrochemical Alkaline Phosphatase (ALP) Biosensors: Recent Approaches in Cells Culture Techniques. BIOSENSORS 2019; 9:E102. [PMID: 31450819 PMCID: PMC6784369 DOI: 10.3390/bios9030102] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Revised: 08/15/2019] [Accepted: 08/19/2019] [Indexed: 12/12/2022]
Abstract
Alkaline phosphatase (ALP), which catalyzes the dephosphorylation process of proteins, nucleic acids, and small molecules, can be found in a variety of tissues (intestine, liver, bone, kidney, and placenta) of almost all living organisms. This enzyme has been extensively used as a biomarker in enzyme immunoassays and molecular biology. ALP is also one of the most commonly assayed enzymes in routine clinical practice. Due to its close relation to a variety of pathological processes, ALP's abnormal level is an important diagnostic biomarker of many human diseases, such as liver dysfunction, bone diseases, kidney acute injury, and cancer. Therefore, the development of convenient and reliable assay methods for monitoring ALP activity/level is extremely important and valuable, not only for clinical diagnoses but also in the area of biomedical research. This paper comprehensively reviews the strategies of optical and electrochemical detection of ALP and discusses the electrochemical techniques that have been addressed to make them suitable for ALP analysis in cell culture.
Collapse
Affiliation(s)
- Thanih Balbaied
- University College Cork, Sensing & Separation Group, School of Chemistry and life Science Interface, Tyndall National Institute, T12R5CP Cork, Ireland
| | - Eric Moore
- University College Cork, Sensing & Separation Group, School of Chemistry and life Science Interface, Tyndall National Institute, T12R5CP Cork, Ireland.
| |
Collapse
|
6
|
Gosset A, Durrieu C, Barbe P, Bazin C, Bayard R. Microalgal whole-cell biomarkers as sensitive tools for fast toxicity and pollution monitoring of urban wet weather discharges. CHEMOSPHERE 2019; 217:522-533. [PMID: 30445397 DOI: 10.1016/j.chemosphere.2018.11.033] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/15/2018] [Revised: 11/02/2018] [Accepted: 11/03/2018] [Indexed: 06/09/2023]
Abstract
Urban wet weather discharge (UWWD) management is an important issue. UWWD often represents a significant source of pollution in all aquatic bodies. The occurrence of this pollution is difficult to predict due to the variability of storm events and the unknown contents of urban watershed leached out by rain. Previous studies have tried to demonstrate the ecotoxic impact of UWWD. However, most of them merely highlight the limitations of classic monospecific bioassays, given the high dilution of micropollutants or the presence of nutrients masking toxic effects. Overcoming this problem is therefore of great interest. In this study, we demonstrated the utility of a battery of biomarkers (e.g. membrane permeability, chlorophyll fluorescence, esterase and alkaline phosphatase activities) on the microalgae Chlorella vulgaris to detect the toxic effects of 7 UWWD samples after short exposures (2 and 24 h). These biomarkers are linked to microalgal life traits. Complementarily, monospecific bioassays were carried on Pseudokirchneriella subcapitata, Chlorella vulgaris, Daphnia magna and Heterocypris incongruens to compare their sensitivity to the UWWD samples. No toxic effect was detected in any of the bioassays. Yet, algal biomarkers indicated a disturbance in microalgae physiology, and particularly a perturbation of chlorophyll fluorescence, which was observed in all of the samples tested. While algal membrane permeability was affected by only one UWWD, these two enzymatic activities were stimulated or inhibited depending on the sample. Finally, this study demonstrates the sensitivity of algal biomarkers and the need to develop new, fruitful approaches to characterizing UWWD toxicity.
Collapse
Affiliation(s)
- Antoine Gosset
- Université de Lyon, ENTPE, CNRS, UMR 5023 LEHNA, 2 Rue Maurice Audin, 69518 Vaulx-en-Velin, France; Université de Lyon, INSA-Lyon, DEEP - EA 7429, 9 rue de la Physique, F69621 Villeurbanne Cedex, France.
| | - Claude Durrieu
- Université de Lyon, ENTPE, CNRS, UMR 5023 LEHNA, 2 Rue Maurice Audin, 69518 Vaulx-en-Velin, France
| | - Pauline Barbe
- Université de Lyon, ENTPE, CNRS, UMR 5023 LEHNA, 2 Rue Maurice Audin, 69518 Vaulx-en-Velin, France
| | - Christine Bazin
- PROVADEMSE, Boulevard Niels Bohr, CS 52132, 69603 Villeurbanne Cedex, France
| | - Rémy Bayard
- Université de Lyon, INSA-Lyon, DEEP - EA 7429, 9 rue de la Physique, F69621 Villeurbanne Cedex, France
| |
Collapse
|
7
|
Specific Immobilization of Escherichia coli Expressing Recombinant Glycerol Dehydrogenase on Mannose-Functionalized Magnetic Nanoparticles. Catalysts 2018. [DOI: 10.3390/catal9010007] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
Mannose-functionalized magnetic nanoparticles were prepared for the immobilization of Escherichia coli cells harboring the recombinant glycerol dehydrogenase gene. Immobilization of whole E. coli cells on the carrier was carried out through specific binding between mannose on the nanoparticles and the FimH lectin on the E. coli cell surface via hydrogen bonds and hydrophobic interactions. The effects of various factors including cell concentration, pH, temperature, and buffer concentration were investigated. High degrees of immobilization (84%) and recovery of activity (82%) were obtained under the following conditions: cell/support 1.3 mg/mL, immobilization time 2 h, pH 8.0, temperature 4°C, and buffer concentration 50 mM. Compared with the free cells, the thermostability of the immobilized cells was improved 2.56-fold at 37 °C. More than 50% of the initial activity of the immobilized cells remained after 10 cycles. The immobilized cells were evaluated functionally by monitoring the catalytic conversion of glycerol to 1,3-dihydroxyacetone (DHA). After a 12 h reaction, the DHA produced by the immobilized cells was two-fold higher than that produced by the free cells. These results indicate that mannose-functionalized magnetic nanoparticles can be used for the specific recognition of gram-negative bacteria, which gives them great potential in applications such as the preparation of biocatalysts and biosensors and clinical diagnosis.
Collapse
|
8
|
Chawla P, Kaushik R, Shiva Swaraj V, Kumar N. Organophosphorus pesticides residues in food and their colorimetric detection. ACTA ACUST UNITED AC 2018. [DOI: 10.1016/j.enmm.2018.07.013] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
9
|
Detection of AFB1 via TiO2 Nanotubes/Au Nanoparticles/Enzyme Photoelectrochemical Biosensor. COATINGS 2018. [DOI: 10.3390/coatings8030090] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
|
10
|
Sharifian S, Homaei A, Kim SK, Satari M. Production of newfound alkaline phosphatases from marine organisms with potential functions and industrial applications. Process Biochem 2018. [DOI: 10.1016/j.procbio.2017.10.005] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
11
|
Zhuang MY, Wang C, Xu MQ, Ling XM, Shen JJ, Zhang YW. Using concanavalinA as a spacer for immobilization of E. coli onto magnetic nanoparticles. Int J Biol Macromol 2017; 104:63-69. [DOI: 10.1016/j.ijbiomac.2017.05.150] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2017] [Revised: 05/23/2017] [Accepted: 05/24/2017] [Indexed: 01/07/2023]
|
12
|
Gosset A, Ferro Y, Durrieu C. Methods for evaluating the pollution impact of urban wet weather discharges on biocenosis: A review. WATER RESEARCH 2016; 89:330-354. [PMID: 26720196 DOI: 10.1016/j.watres.2015.11.020] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2015] [Revised: 11/02/2015] [Accepted: 11/07/2015] [Indexed: 06/05/2023]
Abstract
Rainwater becomes loaded with a large number of pollutants when in contact with the atmosphere and urban surfaces. These pollutants (such as metals, pesticides, PAHs, PCBs) reduce the quality of water bodies. As it is now acknowledged that physico-chemical analyses alone are insufficient for identifying an ecological impact, these analyses are frequently completed or replaced by impact studies communities living in freshwater ecosystems (requiring biological indices), ecotoxicological studies, etc. Thus, different monitoring strategies have been developed over recent decades aimed at evaluating the impact of the pollution brought by urban wet weather discharges on the biocenosis of receiving aquatic ecosystems. The purpose of this review is to establish a synthetic and critical view of these different methods used, to define their advantages and disadvantages, and to provide recommendations for futures researches. Although studies on aquatic communities are used efficiently, notably on benthic macroinvertebrates, they are difficult to interpret. In addition, despite the fact that certain bioassays lack representativeness, the literature at present appears meagre regarding ecotoxicological studies conducted in situ. However, new tools for studying urban wet weather discharges have emerged, namely biosensors. The advantages of biosensors are that they allow monitoring the impact of discharges in situ and continuously. However, only one study on this subject has been identified so far, making it necessary to perform further research in this direction.
Collapse
Affiliation(s)
- Antoine Gosset
- Université de Lyon, ENTPE, CNRS, UMR 5023 LEHNA, 3 Rue Maurice Audin, 69518 Vaulx-en-Velin, France.
| | - Yannis Ferro
- Université de Lyon, ENTPE, CNRS, UMR 5023 LEHNA, 3 Rue Maurice Audin, 69518 Vaulx-en-Velin, France
| | - Claude Durrieu
- Université de Lyon, ENTPE, CNRS, UMR 5023 LEHNA, 3 Rue Maurice Audin, 69518 Vaulx-en-Velin, France
| |
Collapse
|
13
|
Siebman C, Velev OD, Slaveykova VI. Two-Dimensional Algal Collection and Assembly by Combining AC-Dielectrophoresis with Fluorescence Detection for Contaminant-Induced Oxidative Stress Sensing. BIOSENSORS 2015; 5:319-36. [PMID: 26083806 PMCID: PMC4493552 DOI: 10.3390/bios5020319] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/13/2015] [Revised: 05/31/2015] [Accepted: 06/05/2015] [Indexed: 12/23/2022]
Abstract
An alternative current (AC) dielectrophoretic lab-on-chip setup was evaluated as a rapid tool of capture and assembly of microalga Chlamydomonas reinhardtii in two-dimensional (2D) close-packed arrays. An electric field of 100 V·cm⁻¹, 100 Hz applied for 30 min was found optimal to collect and assemble the algae into single-layer structures of closely packed cells without inducing cellular oxidative stress. Combined with oxidative stress specific staining and fluorescence microscopy detection, the capability of using the 2D whole-cell assembly on-chip to follow the reactive oxygen species (ROS) production and oxidative stress during short-term exposure to several environmental contaminants, including mercury, methylmercury, copper, copper oxide nanoparticles (CuO-NPs), and diuron was explored. The results showed significant increase of the cellular ROS when C. reinhardtii was exposed to high concentrations of methylmercury, CuO-NPs, and 10⁻⁵ M Cu. Overall, this study demonstrates the potential of combining AC-dielectrophoretically assembled two-dimensional algal structures with cell metabolic analysis using fluorescence staining, as a rapid analytical tool for probing the effect of contaminants in highly impacted environment.
Collapse
Affiliation(s)
- Coralie Siebman
- Environmental Biogeochemistry and Ecotoxicology, Institute F.-A. Forel, Earth and Environmental Science, Faculty of Sciences, University of Geneva, 10 route de Suisse, Versoix CH-1290, Switzerland.
| | - Orlin D Velev
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, NC 27695, USA.
| | - Vera I Slaveykova
- Environmental Biogeochemistry and Ecotoxicology, Institute F.-A. Forel, Earth and Environmental Science, Faculty of Sciences, University of Geneva, 10 route de Suisse, Versoix CH-1290, Switzerland.
| |
Collapse
|
14
|
Lim JW, Ha D, Lee J, Lee SK, Kim T. Review of micro/nanotechnologies for microbial biosensors. Front Bioeng Biotechnol 2015; 3:61. [PMID: 26029689 PMCID: PMC4426784 DOI: 10.3389/fbioe.2015.00061] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2015] [Accepted: 04/20/2015] [Indexed: 01/28/2023] Open
Abstract
A microbial biosensor is an analytical device with a biologically integrated transducer that generates a measurable signal indicating the analyte concentration. This method is ideally suited for the analysis of extracellular chemicals and the environment, and for metabolic sensory regulation. Although microbial biosensors show promise for application in various detection fields, some limitations still remain such as poor selectivity, low sensitivity, and impractical portability. To overcome such limitations, microbial biosensors have been integrated with many recently developed micro/nanotechnologies and applied to a wide range of detection purposes. This review article discusses micro/nanotechnologies that have been integrated with microbial biosensors and summarizes recent advances and the applications achieved through such novel integration. Future perspectives on the combination of micro/nanotechnologies and microbial biosensors will be discussed, and the necessary developments and improvements will be strategically deliberated.
Collapse
Affiliation(s)
- Ji Won Lim
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea
| | - Dogyeong Ha
- Department of Mechanical Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea
| | - Jongwan Lee
- Department of Mechanical Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea
| | - Sung Kuk Lee
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea
- Department of Chemical Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea
| | - Taesung Kim
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea
- Department of Mechanical Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea
| |
Collapse
|
15
|
March G, Nguyen TD, Piro B. Modified electrodes used for electrochemical detection of metal ions in environmental analysis. BIOSENSORS-BASEL 2015; 5:241-75. [PMID: 25938789 PMCID: PMC4493548 DOI: 10.3390/bios5020241] [Citation(s) in RCA: 148] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/30/2014] [Revised: 04/14/2015] [Accepted: 04/22/2015] [Indexed: 01/16/2023]
Abstract
Heavy metal pollution is one of the most serious environmental problems, and regulations are becoming stricter. Many efforts have been made to develop sensors for monitoring heavy metals in the environment. This review aims at presenting the different label-free strategies used to develop electrochemical sensors for the detection of heavy metals such as lead, cadmium, mercury, arsenic etc. The first part of this review will be dedicated to stripping voltammetry techniques, on unmodified electrodes (mercury, bismuth or noble metals in the bulk form), or electrodes modified at their surface by nanoparticles, nanostructures (CNT, graphene) or other innovative materials such as boron-doped diamond. The second part will be dedicated to chemically modified electrodes especially those with conducting polymers. The last part of this review will focus on bio-modified electrodes. Special attention will be paid to strategies using biomolecules (DNA, peptide or proteins), enzymes or whole cells.
Collapse
Affiliation(s)
| | - Tuan Dung Nguyen
- Institute for Tropical Technology, Vietnam Academy of Science and Technology, 18 Hoang Quoc Viet, Cau Giay District, Hanoi, Vietnam.
| | - Benoit Piro
- Chemistry Department, University Paris Diderot, Sorbonne Paris Cité, ITODYS, UMR 7086 CNRS, 15 rue J-A de Baïf, 75205 Paris Cedex 13, France.
| |
Collapse
|
16
|
Sarkar D, Shimizu K. An overview on biofuel and biochemical production by photosynthetic microorganisms with understanding of the metabolism and by metabolic engineering together with efficient cultivation and downstream processing. BIORESOUR BIOPROCESS 2015. [DOI: 10.1186/s40643-015-0045-9] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
|
17
|
Tekaya N, Saiapina O, Ouada HB, Lagarde F, Namour P, Ouada HB, Jaffrezic-Renault N. Bi-Enzymatic Conductometric Biosensor for Detection of Heavy Metal Ions and Pesticides in Water Samples Based on Enzymatic Inhibition in <i>Arthrospira platensis</i>. ACTA ACUST UNITED AC 2014. [DOI: 10.4236/jep.2014.55047] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
18
|
Tekaya N, Saiapina O, Ben Ouada H, Lagarde F, Ben Ouada H, Jaffrezic-Renault N. Ultra-sensitive conductometric detection of pesticides based on inhibition of esterase activity in Arthrospira platensis. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2013; 178:182-188. [PMID: 23583674 DOI: 10.1016/j.envpol.2013.03.013] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2012] [Revised: 03/02/2013] [Accepted: 03/04/2013] [Indexed: 06/02/2023]
Abstract
Enzymatic conductometric biosensor, using immobilized Arthrospira platensis cells on gold interdigitated electrodes, for the detection of pesticides in water, was elaborated. Cholinesterase activity (AChE) was inhibited by pesticides and a variation of the local conductivity was measured after addition of the substrate acetylthiocholine chloride (AChCl). The Michaelis-Menten constant (Km) was evaluated to be 1.8 mM through a calibration curve of AChCl. Inhibition of AChE was observed with paraoxon-methyl, parathion-methyl, triazine and diuron with a detection limit of 10(-18) M, 10(-20) M, 10(-20) M and 10(-12) M, respectively and the half maximal inhibitory concentration (IC50) was determined at 10(-16) M, 10(-20) M, 10(-18) M and 10(-06) M, respectively. An important decrease of response time τ90% was recorded for AChE response towards AChCl after 30 min cell exposure to pesticides. Scanning electron microscopy images revealed a degradation of the cell surface in presence of pesticides at 10(-06) M.
Collapse
Affiliation(s)
- Nadèje Tekaya
- University of Lyon, Institut des Sciences Analytiques, CNRS/ENS/UCBL UMR 5280, 69100 Villeurbanne, France.
| | | | | | | | | | | |
Collapse
|
19
|
Ultra-sensitive conductometric detection of heavy metals based on inhibition of alkaline phosphatase activity from Arthrospira platensis. Bioelectrochemistry 2013; 90:24-9. [DOI: 10.1016/j.bioelechem.2012.10.001] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2012] [Revised: 10/18/2012] [Accepted: 10/21/2012] [Indexed: 11/23/2022]
|
20
|
Schaap A, Rohrlack T, Bellouard Y. Lab on a chip technologies for algae detection: a review. JOURNAL OF BIOPHOTONICS 2012; 5:661-672. [PMID: 22693123 DOI: 10.1002/jbio.201200051] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2012] [Revised: 04/19/2012] [Accepted: 04/25/2012] [Indexed: 06/01/2023]
Abstract
Over the last few decades, lab on a chip technologies have emerged as powerful tools for high-accuracy diagnosis with minute quantities of liquid and as tools for exploring cell properties in general. In this paper, we present a review of the current status of this technology in the context of algae detection and monitoring. We start with an overview of the detection methods currently used for algae monitoring, followed by a review of lab on a chip devices for algae detection and classification, and then discuss a case study based on our own research activities. We conclude with a discussion on future challenges and motivations for algae-oriented lab on a chip technologies.
Collapse
Affiliation(s)
- Allison Schaap
- Mechanical Engineering Department, Eindhoven University of Technology, The Netherlands
| | | | | |
Collapse
|
21
|
Lam MK, Lee KT. Microalgae biofuels: A critical review of issues, problems and the way forward. Biotechnol Adv 2012; 30:673-90. [DOI: 10.1016/j.biotechadv.2011.11.008] [Citation(s) in RCA: 513] [Impact Index Per Article: 39.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2011] [Revised: 11/16/2011] [Accepted: 11/25/2011] [Indexed: 01/22/2023]
|
22
|
Sassolas A, Prieto-Simón B, Marty JL. Biosensors for Pesticide Detection: New Trends. ACTA ACUST UNITED AC 2012. [DOI: 10.4236/ajac.2012.33030] [Citation(s) in RCA: 145] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
23
|
Durrieu C, Guedri H, Fremion F, Volatier L. Unicellular algae used as biosensors for chemical detection in Mediterranean lagoon and coastal waters. Res Microbiol 2011; 162:908-14. [PMID: 21810469 DOI: 10.1016/j.resmic.2011.07.002] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2010] [Accepted: 07/01/2011] [Indexed: 11/18/2022]
Abstract
Lagoons and coastal waters are contaminated by a large number of chemicals discharged directly or carried by rivers and runoff water that drain catchment areas in which agricultural activities take place. The inflow of these exogenous compounds constitutes a genuine risk for the health of ecosystems. It is therefore important to detect their presence in the natural environment before they cause irreversible damage. Here we present a study aimed at developing a tool for rapid detection of pesticides and other chemicals in environments liable to be contaminated, in order to propose an early warning system for decision-makers. The study carried out focuses on two herbicides commonly encountered in the environment, i.e. diuron and glyphosate, as well as several of their photodegradation products (DCPU, DCPMU, AMPA). The results presented contribute toward developing a biosensor based on measuring the metabolic activities of immobilized unicellular marine algae. The sensor's operation is based on measuring the esterase localized on the external membrane of the algae cells and chlorophyll fluorescence. The tests carried out show that the signal emitted by the sensor is disturbed by the presence of the two herbicides studied. The system proposed appears useful as a tool for controlling environments requiring monitoring.
Collapse
Affiliation(s)
- Claude Durrieu
- ENTPE, Université de Lyon, rue Maurice Audin, 69518 Vaulx-en-Velin cédex, France.
| | | | | | | |
Collapse
|
24
|
Micro-algal biosensors. Anal Bioanal Chem 2011; 401:581-97. [PMID: 21626188 DOI: 10.1007/s00216-011-5107-z] [Citation(s) in RCA: 61] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2011] [Revised: 05/04/2011] [Accepted: 05/13/2011] [Indexed: 10/18/2022]
Abstract
Fighting against water pollution requires the ability to detect pollutants for example herbicides or heavy metals. Micro-algae that live in marine and fresh water offer a versatile solution for the construction of novel biosensors. These photosynthetic microorganisms are very sensitive to changes in their environment, enabling the detection of traces of pollutants. Three groups of micro-algae are described in this paper: chlorophyta, cyanobacteria, and diatoms.
Collapse
|
25
|
Cell-based electrochemical biosensors for water quality assessment. Anal Bioanal Chem 2011; 400:947-64. [PMID: 21424523 DOI: 10.1007/s00216-011-4816-7] [Citation(s) in RCA: 71] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2010] [Revised: 02/11/2011] [Accepted: 02/16/2011] [Indexed: 12/19/2022]
Abstract
During recent decades, extensive industrialisation and farming associated with improper waste management policies have led to the release of a wide range of toxic compounds into aquatic ecosystems, causing a rapid decrease of world freshwater resources and thus requiring urgent implementation of suitable legislation to define water remediation and protection strategies. In Europe, the Water Framework Directive aims to restore good qualitative and quantitative status to all water bodies by 2015. To achieve that, extensive monitoring programmes will be required, calling for rapid, reliable and cost-effective analytical methods for monitoring and toxicological impact assessment of water pollutants. In this context, whole cell biosensors appear as excellent alternatives to or techniques complementary to conventional chemical methods. Cells are easy to cultivate and manipulate, host many enzymes able to catalyse a wide range of biological reactions and can be coupled to various types of transducers. In addition, they are able to provide information about the bioavailability and the toxicity of the pollutants towards eukaryotic or prokaryotic cells. In this article, we present an overview of the use of whole cells, mainly bacteria, yeasts and algae, as sensing elements in electrochemical biosensors with respect to their practical applications in water quality monitoring, with particular emphasis on new trends and future perspectives. In contrast to optical detection, electrochemical transduction is not sensitive to light, can be used for analysis of turbid samples and does not require labelling. In some cases, it is also possible to achieve higher selectivities, even without cell modification, by operating at specific potentials where interferences are limited.
Collapse
|
26
|
Su L, Jia W, Hou C, Lei Y. Microbial biosensors: A review. Biosens Bioelectron 2011; 26:1788-99. [DOI: 10.1016/j.bios.2010.09.005] [Citation(s) in RCA: 325] [Impact Index Per Article: 23.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2010] [Revised: 08/29/2010] [Accepted: 09/02/2010] [Indexed: 02/01/2023]
|
27
|
Hnaien M, Lagarde F, Bausells J, Errachid A, Jaffrezic-Renault N. A new bacterial biosensor for trichloroethylene detection based on a three-dimensional carbon nanotubes bioarchitecture. Anal Bioanal Chem 2010; 400:1083-92. [DOI: 10.1007/s00216-010-4336-x] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2010] [Revised: 10/07/2010] [Accepted: 10/12/2010] [Indexed: 12/25/2022]
|
28
|
Eltzov E, Marks RS. Whole-cell aquatic biosensors. Anal Bioanal Chem 2010; 400:895-913. [DOI: 10.1007/s00216-010-4084-y] [Citation(s) in RCA: 86] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2010] [Revised: 07/13/2010] [Accepted: 08/02/2010] [Indexed: 11/28/2022]
|
29
|
Highly sensitive electrochemical immunoassay for human IgG using double-encoded magnetic redox-active nanoparticles. Mikrochim Acta 2010. [DOI: 10.1007/s00604-010-0442-x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
30
|
Namour P, Lepot M, Jaffrezic-Renault N. Recent trends in monitoring of European water framework directive priority substances using micro-sensors: a 2007-2009 review. SENSORS 2010; 10:7947-78. [PMID: 22163635 PMCID: PMC3231208 DOI: 10.3390/s100907947] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 06/12/2010] [Revised: 07/21/2010] [Accepted: 08/09/2010] [Indexed: 11/16/2022]
Abstract
This review discusses from a critical perspective the development of new sensors for the measurement of priority pollutants targeted in the E.U. Water Framework Directive. Significant advances are reported in the paper and their advantages and limitations are also discussed. Future perspectives in this area are also pointed out in the conclusions. This review covers publications appeared since December 2006 (the publication date of the Swift report). Among priority substances, sensors for monitoring the four WFD metals represent 81% of published papers. None of analyzed publications present a micro-sensor totally validated in laboratory, ready for tests under real conditions in the field. The researches are mainly focused on the sensing part of the micro-sensors. Nevertheless, the main factor limiting micro-sensor applications in the environment is the ruggedness of the receptor towards environmental conditions. This point constitutes the first technological obstacle to be overcome for any long-term field tests.
Collapse
Affiliation(s)
- Philippe Namour
- Université de Lyon, Laboratory of Analytical Sciences, UMR CNRS 5180, 43 boulevard 11 novembre 1918, F-69622, Villeurbanne cedex, France; E-Mail: (N.J.-R)
- Cemagref, UR MALY, CP 220, F-69336, Lyon cedex 09, France
- Author to whom correspondence should be addressed; E-Mail: ; Tel.: +33-472448306; Fax: +33-472431206
| | - Mathieu Lepot
- Université de Lyon, INSA Lyon, LGCIE, 34 Avenue des arts, F-69621 Villeurbanne Cedex, France; E-Mail: (M.L.)
| | - Nicole Jaffrezic-Renault
- Université de Lyon, Laboratory of Analytical Sciences, UMR CNRS 5180, 43 boulevard 11 novembre 1918, F-69622, Villeurbanne cedex, France; E-Mail: (N.J.-R)
| |
Collapse
|
31
|
Isolation and characterization of Acidithiobacillus caldus from a sulfur-oxidizing bacterial biosensor and its role in detection of toxic chemicals. J Microbiol Methods 2010; 82:151-5. [DOI: 10.1016/j.mimet.2010.05.008] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2010] [Revised: 05/10/2010] [Accepted: 05/16/2010] [Indexed: 11/21/2022]
|
32
|
Wang X, Tao G, Meng Y. Nanogold hollow microsphere-based electrochemical immunosensor for the detection of ferritin in human serum. Mikrochim Acta 2009. [DOI: 10.1007/s00604-009-0225-4] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
33
|
Endo T, Tsuji K, Tanaka Y, Yanagida Y, Hatsuzawa T. Design and fabrication of cell alignment device based on electrolytically-generated air bubbles, and its practical realization using polystyrene microbeads. Mikrochim Acta 2008. [DOI: 10.1007/s00604-008-0102-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|