1
|
Concannon J, Máirtín EÓ, FitzGibbon B, Hynes N, Sultan S, McGarry JP. On the Importance of Including Cohesive Zone Models in Modelling Mixed-Mode Aneurysm Rupture. Cardiovasc Eng Technol 2024; 15:633-646. [PMID: 38987509 PMCID: PMC11582104 DOI: 10.1007/s13239-024-00740-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Accepted: 06/21/2024] [Indexed: 07/12/2024]
Abstract
INTRODUCTION The precise mechanism of rupture in abdominal aortic aneurysms (AAAs) has not yet been uncovered. The phenomenological failure criterion of the coefficient of proportionality between von Mises stress and tissue strength does not account for any mechanistic foundation of tissue fracture. Experimental studies have shown that arterial failure is a stepwise process of fibrous delamination (mode II) and kinking (mode I) between layers. Such a mechanism has not previously been considered for AAA rupture. METHODS In the current study we consider both von Mises stress in the wall, in addition to interlayer tractions and delamination using cohesive zone models. Firstly, we present a parametric investigation of the influence of a range of AAA anatomical features on the likelihood of elevated interlayer traction and delamination. RESULTS We observe in several cases that the location of peak von Mises stress and tangential traction coincide. Our simulations also reveal however, that peak von Mises and intramural tractions are not coincident for aneurysms with Length/Radius less than 2 (short high-curvature aneurysms) and for aneurysms with symmetric intraluminal thrombus (ILT). For an aneurysm with (L/R = 2.0), the peak σ vm moves slightly towards the origin while the peak T t is near the peak bulge with a separation distance of ~ 17 mm. Additionally, we present three patient-specific AAA models derived directly from CT scans, which also illustrate that the location of von Mises stress does not correlate with the point of interlayer delamination. CONCLUSION This study suggests that incorporating cohesive zone models into clinical based FE analyses may capture a greater proportion of ruptures in-silico.
Collapse
Affiliation(s)
- J Concannon
- Biomedical Engineering, University of Galway, Galway, Ireland.
| | - E Ó Máirtín
- Biomedical Engineering, University of Galway, Galway, Ireland
| | - B FitzGibbon
- Biomedical Engineering, University of Galway, Galway, Ireland
| | - N Hynes
- Department of Vascular and Endovascular Surgery, Galway University Hospitals, Galway, Ireland
| | - S Sultan
- Department of Vascular and Endovascular Surgery, Galway University Hospitals, Galway, Ireland
| | - J P McGarry
- Biomedical Engineering, University of Galway, Galway, Ireland
| |
Collapse
|
2
|
Riazi G, Brizais C, Garali I, Al-rifai R, Quelquejay H, Monceau V, Vares G, Ould-Boukhitine L, Aubeleau D, Gilain F, Gloaguen C, Dos Santos M, Ait-Oufella H, Ebrahimian T. Effects of moderate doses of ionizing radiation on experimental abdominal aortic aneurysm. PLoS One 2024; 19:e0308273. [PMID: 39088551 PMCID: PMC11293671 DOI: 10.1371/journal.pone.0308273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2024] [Accepted: 07/18/2024] [Indexed: 08/03/2024] Open
Abstract
BACKGROUND Exposure to ionizing radiation has been linked to cardiovascular diseases. However, the impact of moderate doses of radiation on abdominal aortic aneurysm (AAA) remains unknown. METHODS Angiotensin II-infused Apoe-/- mice were irradiated (acute, 1 Gray) either 3 days before (Day-3) or 1 day after (Day+1) pomp implantation. Isolated primary aortic vascular smooth muscle cells (VSMCs) were irradiated (acute 1 Gray) for mechanistic studies and functional testing in vitro. RESULTS Day-3 and Day+1 irradiation resulted in a significant reduction in aorta dilation (Control: 1.39+/-0.12; Day-3: 1.12+/-0.11; Day+1: 1.15+/-0.08 mm, P<0.001) and AAA incidence (Control: 81.0%; Day-3: 33.3%, Day+1: 53.3%) compared to the non-irradiated group. Day-3 and Day+1 irradiation led to an increase in collagen content in the adventitia (Thickness control: 23.64+/-2.9; Day-3: 54.39+/-15.5; Day+1 37.55+/-10.8 mm, P = 0.006). However, the underlying protective mechanisms were different between Day-3 and Day+1 groups. Irradiation before Angiotensin II (AngII) infusion mainly modulated vascular smooth muscle cell (VSMC) phenotype with a decrease in contractile profile and enhanced proliferative and migratory activity. Irradiation after AngII infusion led to an increase in macrophage content with a local anti-inflammatory phenotype characterized by the upregulation of M2-like gene and IL-10 expression. CONCLUSION Moderate doses of ionizing radiation mitigate AAA either through VSCM phenotype or inflammation modulation, depending on the time of irradiation.
Collapse
MESH Headings
- Animals
- Aortic Aneurysm, Abdominal/pathology
- Aortic Aneurysm, Abdominal/metabolism
- Aortic Aneurysm, Abdominal/etiology
- Mice
- Muscle, Smooth, Vascular/metabolism
- Muscle, Smooth, Vascular/radiation effects
- Muscle, Smooth, Vascular/pathology
- Radiation, Ionizing
- Angiotensin II/pharmacology
- Myocytes, Smooth Muscle/metabolism
- Myocytes, Smooth Muscle/radiation effects
- Myocytes, Smooth Muscle/pathology
- Male
- Disease Models, Animal
- Interleukin-10/metabolism
- Interleukin-10/genetics
- Collagen/metabolism
- Cell Proliferation/radiation effects
Collapse
Affiliation(s)
- Goran Riazi
- Experimental Radiotoxicology and Radiobiology Laboratory (LRTOX), Institute for Radiobiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
| | - Chloe Brizais
- Experimental Radiotoxicology and Radiobiology Laboratory (LRTOX), Institute for Radiobiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
| | - Imene Garali
- Experimental Radiotoxicology and Radiobiology Laboratory (LRTOX), Institute for Radiobiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
| | - Rida Al-rifai
- Université de Paris, Inserm U970, Paris-Cardiovascular Research Center, Paris, France
| | - Helene Quelquejay
- Experimental Radiotoxicology and Radiobiology Laboratory (LRTOX), Institute for Radiobiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
| | - Virginie Monceau
- Experimental Radiotoxicology and Radiobiology Laboratory (LRTOX), Institute for Radiobiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
| | - Guillaume Vares
- Experimental Radiotoxicology and Radiobiology Laboratory (LRTOX), Institute for Radiobiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
| | - Lea Ould-Boukhitine
- Experimental Radiotoxicology and Radiobiology Laboratory (LRTOX), Institute for Radiobiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
| | - Damien Aubeleau
- Experimental Radiotoxicology and Radiobiology Laboratory (LRTOX), Institute for Radiobiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
| | - Florian Gilain
- Experimental Radiotoxicology and Radiobiology Laboratory (LRTOX), Institute for Radiobiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
| | - Celine Gloaguen
- Experimental Radiotoxicology and Radiobiology Laboratory (LRTOX), Institute for Radiobiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
| | - Morgane Dos Santos
- Accidental Exposure Radiobiology Laboratory (LRACC), Institute for Radiobiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
| | - Hafid Ait-Oufella
- Université de Paris, Inserm U970, Paris-Cardiovascular Research Center, Paris, France
- Medical Intensive Care Unit, Hôpital Saint-Antoine, AP-HP, Sorbonne Université, Paris, France
| | - Teni Ebrahimian
- Experimental Radiotoxicology and Radiobiology Laboratory (LRTOX), Institute for Radiobiological Protection and Nuclear Safety (IRSN), Fontenay-aux-Roses, France
| |
Collapse
|
3
|
Dong H, Leach JR, Kao E, Zhou A, Chitiboi T, Zhu C, Ballweber M, Jiang F, Lee YJ, Iannuzzi J, Gasper W, Saloner D, Hope MD, Mitsouras D. Measurement of Abdominal Aortic Aneurysm Strain Using MR Deformable Image Registration: Accuracy and Relationship to Recent Aneurysm Progression. Invest Radiol 2024; 59:425-432. [PMID: 37855728 PMCID: PMC11026303 DOI: 10.1097/rli.0000000000001035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2023]
Abstract
BACKGROUND Management of asymptomatic abdominal aortic aneurysm (AAA) based on maximum aneurysm diameter and growth rate fails to preempt many ruptures. Assessment of aortic wall biomechanical properties may improve assessment of progression and rupture risk. This study aimed to assess the accuracy of AAA wall strain measured by cine magnetic resonance imaging (MRI) deformable image registration (MR strain) and investigate its relationship with recent AAA progression. METHODS The MR strain accuracy was evaluated in silico against ground truth strain in 54 synthetic MRIs generated from a finite element model simulation of an AAA patient's abdomen for different aortic pulse pressures, tissue motions, signal intensity variations, and image noise. Evaluation included bias with 95% confidence interval (CI) and correlation analysis. Association of MR strain with AAA growth rate was assessed in 25 consecutive patients with >6 months of prior surveillance, for whom cine balanced steady-state free-precession imaging was acquired at the level of the AAA as well as the proximal, normal-caliber aorta. Univariate and multivariate regressions were used to associate growth rate with clinical variables, maximum AAA diameter (D max ), and peak circumferential MR strain through the cardiac cycle. The MR strain interoperator variability was assessed using bias with 95% CI, intraclass correlation coefficient, and coefficient of variation. RESULTS In silico experiments revealed an MR strain bias of 0.48% ± 0.42% and a slope of correlation to ground truth strain of 0.963. In vivo, AAA MR strain (1.2% ± 0.6%) was highly reproducible (bias ± 95% CI, 0.03% ± 0.31%; intraclass correlation coefficient, 97.8%; coefficient of variation, 7.14%) and was lower than in the nonaneurysmal aorta (2.4% ± 1.7%). D max ( β = 0.087) and MR strain ( β = -1.563) were both associated with AAA growth rate. The MR strain remained an independent factor associated with growth rate ( β = -0.904) after controlling for D max . CONCLUSIONS Deformable image registration analysis can accurately measure the circumferential strain of the AAA wall from standard cine MRI and may offer patient-specific insight regarding AAA progression.
Collapse
Affiliation(s)
- Huiming Dong
- From the Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (H.D., J.L., E.K., A.Z., C.Z., M.B., Y.J.L., D.S., M.H., D.M.); Vascular Imaging Research Center, San Francisco Veteran Affairs Medical Center, San Francisco, CA (H.D., J.L., E.K., A.Z., C.Z., M.B., D.S., M.H., D.M.); Siemens Healthineers (T.C.); Department of Radiology, University of Washington, Seattle, WA (C.Z.); Department of Epidemiology and Biostatistics, University of California, San Francisco, San Francisco, CA (F.J.); Department of Surgery, University of California, San Francisco, San Francisco, CA (J.I., W. G.); and Department of Vascular Surgery, San Francisco Veteran Affairs Medical Center, San Francisco, CA (J.I., W.G.)
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Ren S, Guidoin R, Xu Z, Deng X, Fan Y, Chen Z, Sun A. Narrative Review of Risk Assessment of Abdominal Aortic Aneurysm Rupture Based on Biomechanics-Related Morphology. J Endovasc Ther 2024; 31:178-190. [PMID: 36052406 DOI: 10.1177/15266028221119309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
CLINICAL IMPACT Studies have shown that the biomechanical indicators based on multi-scale models are more effective in accurately assessing the rupture risk of AAA. To meet the need for clinical monitoring and rapid decision making, the typical morphological parameters associated with AAA rupture and their relationships with the mechanical environment have been summarized, which provide a reference for clinical preoperative risk assessment of AAA.
Collapse
Affiliation(s)
- Shuqi Ren
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Robert Guidoin
- Department of Surgery, Faculty of Medicine, Université Laval and CHU de Québec Research Centre, Quebec, QC, Canada
| | - Zaipin Xu
- College of Animal Science, Guizhou University, Guiyang, China
| | - Xiaoyan Deng
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Yubo Fan
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Zengsheng Chen
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Anqiang Sun
- Key Laboratory for Biomechanics and Mechanobiology of Ministry of Education, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| |
Collapse
|
5
|
Mutlu O, Salman HE, Al-Thani H, El-Menyar A, Qidwai UA, Yalcin HC. How does hemodynamics affect rupture tissue mechanics in abdominal aortic aneurysm: Focus on wall shear stress derived parameters, time-averaged wall shear stress, oscillatory shear index, endothelial cell activation potential, and relative residence time. Comput Biol Med 2023; 154:106609. [PMID: 36724610 DOI: 10.1016/j.compbiomed.2023.106609] [Citation(s) in RCA: 38] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Revised: 01/19/2023] [Accepted: 01/22/2023] [Indexed: 01/24/2023]
Abstract
An abdominal aortic aneurysm (AAA) is a critical health condition with a risk of rupture, where the diameter of the aorta enlarges more than 50% of its normal diameter. The incidence rate of AAA has increased worldwide. Currently, about three out of every 100,000 people have aortic diseases. The diameter and geometry of AAAs influence the hemodynamic forces exerted on the arterial wall. Therefore, a reliable assessment of hemodynamics is crucial for predicting the rupture risk. Wall shear stress (WSS) is an important metric to define the level of the frictional force on the AAA wall. Excessive levels of WSS deteriorate the remodeling mechanism of the arteries and lead to abnormal conditions. At this point, WSS-related hemodynamic parameters, such as time-averaged WSS (TAWSS), oscillatory shear index (OSI), endothelial cell activation potential (ECAP), and relative residence time (RRT) provide important information to evaluate the shear environment on the AAA wall in detail. Calculation of these parameters is not straightforward and requires a physical understanding of what they represent. In addition, computational fluid dynamics (CFD) solvers do not readily calculate these parameters when hemodynamics is simulated. This review aims to explain the WSS-derived parameters focusing on how these represent different characteristics of disturbed hemodynamics. A representative case is presented for spatial and temporal formulation that would be useful for interested researchers for practical calculations. Finally, recent hemodynamics investigations relating WSS-related parameters with AAA rupture risk assessment are presented. This review will be useful to understand the physical representation of WSS-related parameters in cardiovascular flows and how they can be calculated practically for AAA investigations.
Collapse
Affiliation(s)
- Onur Mutlu
- Biomedical Research Center, Qatar University, Doha, Qatar
| | - Huseyin Enes Salman
- Department of Mechanical Engineering, TOBB University of Economics and Technology, Ankara, Turkey
| | - Hassan Al-Thani
- Department of Surgery, Trauma and Vascular Surgery, Hamad General Hospital, Hamad Medical Corporation, P.O. Box 3050, Doha, Qatar
| | - Ayman El-Menyar
- Department of Surgery, Trauma and Vascular Surgery, Hamad General Hospital, Hamad Medical Corporation, P.O. Box 3050, Doha, Qatar; Clinical Medicine, Weill Cornell Medical College, Doha, Qatar
| | - Uvais Ahmed Qidwai
- Department of Computer Science Engineering, Qatar University, Doha, Qatar
| | | |
Collapse
|
6
|
Bellamkonda KS, Zogg C, Nassiri N, Sadeghi MM, Zhang Y, Guzman RJ, Ochoa Chaar CI. Characteristics and One-year Outcomes of Patients with Rupture of Small Abdominal Aortic Aneurysms. J Vasc Surg 2023; 77:1649-1657. [PMID: 36796595 DOI: 10.1016/j.jvs.2023.02.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 02/05/2023] [Accepted: 02/06/2023] [Indexed: 02/16/2023]
Abstract
OBJECTIVES Rupture of abdominal aortic aneurysms (rAAA) is typically associated with large sac diameter, however some patients experience rupture before reaching operative thresholds for elective repair. We aim to investigate the characteristics and outcomes of patients who experience small rAAA. METHODS The Vascular Quality Initiative database for open AAA repair and endovascular aneurysm repair (EVAR) from 2003-2020 were reviewed for all rAAA cases. Based on the 2018 Society for Vascular Surgery guidelines on operative size thresholds for elective repair, patients with infrarenal aneurysms <5.0cm in women or <5.5cm in men were categorized as "small rAAA." Patients who met operative thresholds or had a concomitant iliac diameter ≥3.5cm were categorized as "large rAAA.". Patient characteristics and perioperative as well as long-term outcomes were compared via univariate regression. Inverse probability of treatment weighting (IPTW) using propensity scores was employed to examine the relationship between rAAA size and adverse outcomes. RESULTS There were 3,962 cases that met inclusion criteria, with 12.2% small rAAA. The mean aneurysm diameter was 42.3mm and 78.5mm in the small and large rAAA groups, respectively. Patients in the small rAAA group were significantly more likely to be younger, African American, have lower BMI, and had significantly higher rates of hypertension. Small rAAA were more likely to be repaired via EVAR (p=0.001). Hypotension was significantly less likely in patients with small rAAA (p<0.001). Rates of perioperative myocardial infarction (p<0.001), total morbidity (p<0.004) and mortality (p<0.001) were significantly higher for large rAAA cases. After propensity matching, there was no significant difference in mortality between the 2 groups, but smaller rAAA was associated with lower rates of MI (OR=0.50[0.31-0.82]). On long-term follow up, no difference in mortality was noted between the two groups. CONCLUSIONS Patients presenting with small rAAA represent 12.2% of all rAAA and are more likely to be African American. Small rAAA is associated with similar risk of perioperative and long-term mortality compared to rupture at larger size after risk adjustment.
Collapse
Affiliation(s)
| | - Cheryl Zogg
- Yale School of Medicine, New Haven, Connecticut
| | - Naiem Nassiri
- Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, Yale School of Medicine, New Haven, Connecticut
| | - Mehran M Sadeghi
- Cardiovascular Molecular Imaging Laboratory, Section of Cardiovascular Medicine and Yale Cardiovascular Research Center, Yale University School of Medicine, New Haven, Connecticut; Veterans Affairs Connecticut Healthcare System, West Haven, Connecticut
| | - Yawei Zhang
- Yale School of Public Health, New Haven, Connecticut
| | - Raul J Guzman
- Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, Yale School of Medicine, New Haven, Connecticut
| | - Cassius Iyad Ochoa Chaar
- Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, Yale School of Medicine, New Haven, Connecticut
| |
Collapse
|
7
|
Lowis C, Ramara Winaya A, Kumari P, Rivera CF, Vlahos J, Hermantara R, Pratama MY, Ramkhelawon B. Mechanosignals in abdominal aortic aneurysms. Front Cardiovasc Med 2023; 9:1021934. [PMID: 36698932 PMCID: PMC9868277 DOI: 10.3389/fcvm.2022.1021934] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Accepted: 11/29/2022] [Indexed: 01/11/2023] Open
Abstract
Cumulative evidence has shown that mechanical and frictional forces exert distinct effects in the multi-cellular aortic layers and play a significant role in the development of abdominal aortic aneurysms (AAA). These mechanical cues collectively trigger signaling cascades relying on mechanosensory cellular hubs that regulate vascular remodeling programs leading to the exaggerated degradation of the extracellular matrix (ECM), culminating in lethal aortic rupture. In this review, we provide an update and summarize the current understanding of the mechanotransduction networks in different cell types during AAA development. We focus on different mechanosensors and stressors that accumulate in the AAA sac and the mechanotransduction cascades that contribute to inflammation, oxidative stress, remodeling, and ECM degradation. We provide perspectives on manipulating this mechano-machinery as a new direction for future research in AAA.
Collapse
Affiliation(s)
- Christiana Lowis
- Division of Vascular and Endovascular Surgery, Department of Surgery, New York University Langone Medical Center, New York, NY, United States
- Department of Biomedicine, Indonesia International Institute for Life-Sciences, Jakarta, Indonesia
| | - Aurellia Ramara Winaya
- Division of Vascular and Endovascular Surgery, Department of Surgery, New York University Langone Medical Center, New York, NY, United States
- Department of Biomedicine, Indonesia International Institute for Life-Sciences, Jakarta, Indonesia
| | - Puja Kumari
- Division of Vascular and Endovascular Surgery, Department of Surgery, New York University Langone Medical Center, New York, NY, United States
- Department of Cell Biology, New York University Langone Medical Center, New York, NY, United States
| | - Cristobal F. Rivera
- Division of Vascular and Endovascular Surgery, Department of Surgery, New York University Langone Medical Center, New York, NY, United States
- Department of Cell Biology, New York University Langone Medical Center, New York, NY, United States
| | - John Vlahos
- Division of Vascular and Endovascular Surgery, Department of Surgery, New York University Langone Medical Center, New York, NY, United States
- Department of Cell Biology, New York University Langone Medical Center, New York, NY, United States
| | - Rio Hermantara
- Department of Biomedicine, Indonesia International Institute for Life-Sciences, Jakarta, Indonesia
| | - Muhammad Yogi Pratama
- Division of Vascular and Endovascular Surgery, Department of Surgery, New York University Langone Medical Center, New York, NY, United States
- Department of Cell Biology, New York University Langone Medical Center, New York, NY, United States
| | - Bhama Ramkhelawon
- Division of Vascular and Endovascular Surgery, Department of Surgery, New York University Langone Medical Center, New York, NY, United States
- Department of Cell Biology, New York University Langone Medical Center, New York, NY, United States
| |
Collapse
|
8
|
Abstract
Abdominal aortic aneurysm is a potentially lethal condition that is decreasing in frequency as tobacco use declines. The exact etiology remains unknown, but smoking and other perturbations seem to trigger an inflammatory state in the tunica media. Male sex and advanced age are clear demographic risk factors for the development of abdominal aortic aneurysms. The natural history of this disease varies, but screening remains vital as it is rarely diagnosed on physical examination, and elective repair (most commonly done endovascularly) offers significant morbidity and mortality advantages over emergent intervention for aortic rupture.
Collapse
Affiliation(s)
- Michael P Calgi
- University of Virginia School of Medicine, 200 Jeanette Lancaster Way, Charlottesville, VA 22903, USA
| | - John S McNeil
- Department of Anesthesiology, University of Virginia School of Medicine, PO Box 800710, Charlottesville, VA 22908-0710, USA.
| |
Collapse
|
9
|
Arbănași EM, Mureșan AV, Coșarcă CM, Arbănași EM, Niculescu R, Voidăzan ST, Ivănescu AD, Hălmaciu I, Filep RC, Mărginean L, Suzuki S, Chirilă TV, Kaller R, Russu E. Computed Tomography Angiography Markers and Intraluminal Thrombus Morphology as Predictors of Abdominal Aortic Aneurysm Rupture. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:15961. [PMID: 36498041 PMCID: PMC9741090 DOI: 10.3390/ijerph192315961] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Revised: 11/26/2022] [Accepted: 11/28/2022] [Indexed: 06/17/2023]
Abstract
Background: Abdominal aortic aneurysm (AAA) is a complex vascular disease characterized by progressive and irreversible local dilatation of the aortic wall. Currently, the indication for repair is linked to the transverse diameter of the abdominal aorta, using computed tomography angiography imagery, which is one of the most used markers for aneurysmal growth. This study aims to verify the predictive role of imaging markers and underlying risk factors in AAA rupture. Methods: The present study was designed as an observational, analytical, retrospective cohort study and included 220 patients over 18 years of age with a diagnosis of AAA, confirmed by computed tomography angiography (CTA), admitted to Vascular Surgery Clinic of Mures County Emergency Hospital in Targu Mures, Romania, between January 2018 and September 2022. Results: Patients with a ruptured AAA had higher incidences of AH (p = 0.006), IHD (p = 0.001), AF (p < 0.0001), and MI (p < 0.0001), and higher incidences of all risk factors (tobacco (p = 0.001), obesity (p = 0.02), and dyslipidemia (p < 0.0001)). Multivariate analysis showed that a high baseline value of all imaging ratios markers was a strong independent predictor of AAA rupture (for all p < 0.0001). Moreover, a higher baseline value of DAmax (OR:3.91; p = 0.001), SAmax (OR:7.21; p < 0.001), and SLumenmax (OR:34.61; p < 0.001), as well as lower baseline values of DArenal (OR:7.09; p < 0.001), DACT (OR:12.71; p < 0.001), DAfemoral (OR:2.56; p = 0.005), SArenal (OR:4.56; p < 0.001), SACT (OR:3.81; p < 0.001), and SThrombusmax (OR:5.27; p < 0.001) were independent predictors of AAA rupture. In addition, AH (OR:3.33; p = 0.02), MI (OR:3.06; p = 0.002), and PAD (OR:2.71; p = 0.004) were all independent predictors of AAA rupture. In contrast, higher baseline values of SAmax/Lumenmax (OR:0.13; p < 0.001) and ezetimibe (OR:0.45; p = 0.03) were protective factors against AAA rupture. Conclusions: According to our findings, a higher baseline value of all imaging markers ratios at CTA strongly predicts AAA rupture and AH, MI, and PAD highly predicted the risk of rupture in AAA patients. Furthermore, the diameter of the abdominal aorta at different levels has better accuracy and a higher predictive role of rupture than the maximal diameter of AAA.
Collapse
Affiliation(s)
- Emil Marian Arbănași
- Doctoral School of Medicine and Pharmacy, George Emil Palade University of Medicine, Pharmacy, Sciences and Technology of Targu Mures, 540142 Targu Mures, Romania
- Clinic of Vascular Surgery, Mures County Emergency Hospital, 540136 Targu Mures, Romania
| | - Adrian Vasile Mureșan
- Clinic of Vascular Surgery, Mures County Emergency Hospital, 540136 Targu Mures, Romania
- Department of Surgery, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 540139 Targu Mures, Romania
| | - Cătălin Mircea Coșarcă
- Clinic of Vascular Surgery, Mures County Emergency Hospital, 540136 Targu Mures, Romania
| | - Eliza Mihaela Arbănași
- Faculty of Pharmacy, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 540139 Targu Mures, Romania
| | - Raluca Niculescu
- Department of Pathophysiology, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 540139 Targu Mures, Romania
| | - Septimiu Toader Voidăzan
- Department of Epidemiology, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 540139 Targu Mures, Romania
| | - Adrian Dumitru Ivănescu
- Department of Anatomy, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 540139 Targu Mures, Romania
| | - Ioana Hălmaciu
- Department of Anatomy, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 540139 Targu Mures, Romania
| | - Rareș Cristian Filep
- Department of Radiology, Mures County Emergency Hospital, 540136 Targu Mures, Romania
| | - Lucian Mărginean
- Department of Radiology, Mures County Emergency Hospital, 540136 Targu Mures, Romania
| | - Shuko Suzuki
- Queensland Eye Institute, South Brisbane, QLD 4101, Australia
| | - Traian V. Chirilă
- Queensland Eye Institute, South Brisbane, QLD 4101, Australia
- School of Chemistry & Physics, Queensland University of Technology, Brisbane, QLD 4001, Australia
- Australian Institute of Bioengineering & Nanotechnology (AIBN), University of Queensland, St. Lucia, QLD 4072, Australia
- Faculty of Medicine, University of Queensland, Herston, QLD 4006, Australia
- School of Molecular Sciences, University of Western Australia, Crawley, WA 6009, Australia
- Faculty of Medicine, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 540139 Targu Mures, Romania
| | - Réka Kaller
- Doctoral School of Medicine and Pharmacy, George Emil Palade University of Medicine, Pharmacy, Sciences and Technology of Targu Mures, 540142 Targu Mures, Romania
- Clinic of Vascular Surgery, Mures County Emergency Hospital, 540136 Targu Mures, Romania
| | - Eliza Russu
- Clinic of Vascular Surgery, Mures County Emergency Hospital, 540136 Targu Mures, Romania
- Department of Surgery, George Emil Palade University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 540139 Targu Mures, Romania
| |
Collapse
|
10
|
Dong H, Raterman B, White RD, Starr J, Vaccaro P, Haurani M, Go M, Eisner M, Brock G, Kolipaka A. MR Elastography of Abdominal Aortic Aneurysms: Relationship to Aneurysm Events. Radiology 2022; 304:721-729. [PMID: 35638926 PMCID: PMC9434816 DOI: 10.1148/radiol.212323] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2021] [Revised: 03/26/2022] [Accepted: 04/07/2022] [Indexed: 11/11/2022]
Abstract
Background Abdominal aortic aneurysm (AAA) diameter remains the standard clinical parameter to predict growth and rupture. Studies suggest that using solely AAA diameter for risk stratification is insufficient. Purpose To evaluate the use of aortic MR elastography (MRE)-derived AAA stiffness and stiffness ratio at baseline to identify the potential for future aneurysm rupture or need for surgical repair. Materials and Methods Between August 2013 and March 2019, 72 participants with AAA and 56 healthy participants were enrolled in this prospective study. MRE examinations were performed to estimate AAA stiffness and the stiffness ratio between AAA and its adjacent remote normal aorta. Two Cox proportional hazards models were used to assess AAA stiffness and stiffness ratio for predicting aneurysmal events (subsequent repair, rupture, or diameter >5.0 cm). Log-rank tests were performed to determine a critical stiffness ratio suggesting high-risk AAAs. Baseline AAA stiffness and stiffness ratio were studied using Wilcoxon rank-sum tests between participants with and without aneurysmal events. Spearman correlation was used to investigate the relationship between stiffness and other potential imaging markers. Results Seventy-two participants with AAA (mean age, 71 years ± 9 [SD]; 56 men and 16 women) and 56 healthy participants (mean age, 42 years ± 16; 27 men and 29 women) were evaluated. In healthy participants, aortic stiffness positively correlated with age (ρ = 0.44; P < .001). AAA stiffness (event group [n = 21], 50.3 kPa ± 26.5 [SD]; no-event group [n = 21], 86.9 kPa ± 52.6; P = .01) and the stiffness ratio (event group, 0.7 ± 0.4; no-event group, 2.0 ± 1.4; P < .001) were lower in the event group than the no-event group at a mean follow-up of 449 days. AAA stiffness did not correlate with diameter in the event group (ρ = -0.06; P = .68) or the no-event group (ρ = -0.13; P = .32). AAA stiffness was inversely correlated with intraluminal thrombus area (ρ = -0.50; P = .01). Conclusion Lower abdominal aortic aneurysm stiffness and stiffness ratio measured with use of MR elastography was associated with aneurysmal events at a 15-month follow-up. © RSNA, 2022 See also the editorial by Sakuma in this issue.
Collapse
Affiliation(s)
- Huiming Dong
- From the Department of Radiology (H.D., B.R., R.D.W., A.K.), Department of Internal Medicine, Division of Cardiovascular Medicine (R.D.W., A.K.), Department of Surgery (J.S., P.V., M.H., M.G.), and Department of Biomedical Informatics and Center for Biostatistics (M.E., G.B.), College of Medicine, The Ohio State University Wexner Medical Center, 395 W 12th Ave, 4th Floor, Columbus, OH 43210; Department of Biomedical Engineering, College of Engineering, The Ohio State University, Columbus, Ohio (H.D., A.K.); and Department of Radiology, Mayo Clinic, Jacksonville, Fla (R.D.W.)
| | - Brian Raterman
- From the Department of Radiology (H.D., B.R., R.D.W., A.K.), Department of Internal Medicine, Division of Cardiovascular Medicine (R.D.W., A.K.), Department of Surgery (J.S., P.V., M.H., M.G.), and Department of Biomedical Informatics and Center for Biostatistics (M.E., G.B.), College of Medicine, The Ohio State University Wexner Medical Center, 395 W 12th Ave, 4th Floor, Columbus, OH 43210; Department of Biomedical Engineering, College of Engineering, The Ohio State University, Columbus, Ohio (H.D., A.K.); and Department of Radiology, Mayo Clinic, Jacksonville, Fla (R.D.W.)
| | - Richard D. White
- From the Department of Radiology (H.D., B.R., R.D.W., A.K.), Department of Internal Medicine, Division of Cardiovascular Medicine (R.D.W., A.K.), Department of Surgery (J.S., P.V., M.H., M.G.), and Department of Biomedical Informatics and Center for Biostatistics (M.E., G.B.), College of Medicine, The Ohio State University Wexner Medical Center, 395 W 12th Ave, 4th Floor, Columbus, OH 43210; Department of Biomedical Engineering, College of Engineering, The Ohio State University, Columbus, Ohio (H.D., A.K.); and Department of Radiology, Mayo Clinic, Jacksonville, Fla (R.D.W.)
| | - Jean Starr
- From the Department of Radiology (H.D., B.R., R.D.W., A.K.), Department of Internal Medicine, Division of Cardiovascular Medicine (R.D.W., A.K.), Department of Surgery (J.S., P.V., M.H., M.G.), and Department of Biomedical Informatics and Center for Biostatistics (M.E., G.B.), College of Medicine, The Ohio State University Wexner Medical Center, 395 W 12th Ave, 4th Floor, Columbus, OH 43210; Department of Biomedical Engineering, College of Engineering, The Ohio State University, Columbus, Ohio (H.D., A.K.); and Department of Radiology, Mayo Clinic, Jacksonville, Fla (R.D.W.)
| | - Patrick Vaccaro
- From the Department of Radiology (H.D., B.R., R.D.W., A.K.), Department of Internal Medicine, Division of Cardiovascular Medicine (R.D.W., A.K.), Department of Surgery (J.S., P.V., M.H., M.G.), and Department of Biomedical Informatics and Center for Biostatistics (M.E., G.B.), College of Medicine, The Ohio State University Wexner Medical Center, 395 W 12th Ave, 4th Floor, Columbus, OH 43210; Department of Biomedical Engineering, College of Engineering, The Ohio State University, Columbus, Ohio (H.D., A.K.); and Department of Radiology, Mayo Clinic, Jacksonville, Fla (R.D.W.)
| | - Mounir Haurani
- From the Department of Radiology (H.D., B.R., R.D.W., A.K.), Department of Internal Medicine, Division of Cardiovascular Medicine (R.D.W., A.K.), Department of Surgery (J.S., P.V., M.H., M.G.), and Department of Biomedical Informatics and Center for Biostatistics (M.E., G.B.), College of Medicine, The Ohio State University Wexner Medical Center, 395 W 12th Ave, 4th Floor, Columbus, OH 43210; Department of Biomedical Engineering, College of Engineering, The Ohio State University, Columbus, Ohio (H.D., A.K.); and Department of Radiology, Mayo Clinic, Jacksonville, Fla (R.D.W.)
| | - Michael Go
- From the Department of Radiology (H.D., B.R., R.D.W., A.K.), Department of Internal Medicine, Division of Cardiovascular Medicine (R.D.W., A.K.), Department of Surgery (J.S., P.V., M.H., M.G.), and Department of Biomedical Informatics and Center for Biostatistics (M.E., G.B.), College of Medicine, The Ohio State University Wexner Medical Center, 395 W 12th Ave, 4th Floor, Columbus, OH 43210; Department of Biomedical Engineering, College of Engineering, The Ohio State University, Columbus, Ohio (H.D., A.K.); and Department of Radiology, Mayo Clinic, Jacksonville, Fla (R.D.W.)
| | - Mariah Eisner
- From the Department of Radiology (H.D., B.R., R.D.W., A.K.), Department of Internal Medicine, Division of Cardiovascular Medicine (R.D.W., A.K.), Department of Surgery (J.S., P.V., M.H., M.G.), and Department of Biomedical Informatics and Center for Biostatistics (M.E., G.B.), College of Medicine, The Ohio State University Wexner Medical Center, 395 W 12th Ave, 4th Floor, Columbus, OH 43210; Department of Biomedical Engineering, College of Engineering, The Ohio State University, Columbus, Ohio (H.D., A.K.); and Department of Radiology, Mayo Clinic, Jacksonville, Fla (R.D.W.)
| | - Guy Brock
- From the Department of Radiology (H.D., B.R., R.D.W., A.K.), Department of Internal Medicine, Division of Cardiovascular Medicine (R.D.W., A.K.), Department of Surgery (J.S., P.V., M.H., M.G.), and Department of Biomedical Informatics and Center for Biostatistics (M.E., G.B.), College of Medicine, The Ohio State University Wexner Medical Center, 395 W 12th Ave, 4th Floor, Columbus, OH 43210; Department of Biomedical Engineering, College of Engineering, The Ohio State University, Columbus, Ohio (H.D., A.K.); and Department of Radiology, Mayo Clinic, Jacksonville, Fla (R.D.W.)
| | - Arunark Kolipaka
- From the Department of Radiology (H.D., B.R., R.D.W., A.K.), Department of Internal Medicine, Division of Cardiovascular Medicine (R.D.W., A.K.), Department of Surgery (J.S., P.V., M.H., M.G.), and Department of Biomedical Informatics and Center for Biostatistics (M.E., G.B.), College of Medicine, The Ohio State University Wexner Medical Center, 395 W 12th Ave, 4th Floor, Columbus, OH 43210; Department of Biomedical Engineering, College of Engineering, The Ohio State University, Columbus, Ohio (H.D., A.K.); and Department of Radiology, Mayo Clinic, Jacksonville, Fla (R.D.W.)
| |
Collapse
|
11
|
Arun D, Munir W, Schmitt LV, Vyas R, Ravindran JI, Bashir M, Williams IM, Velayudhan B, Idhrees M. Exploring the Correlation and Protective Role of Diabetes Mellitus in Aortic Aneurysm Disease. Front Cardiovasc Med 2021; 8:769343. [PMID: 34820431 PMCID: PMC8606667 DOI: 10.3389/fcvm.2021.769343] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Accepted: 10/11/2021] [Indexed: 01/04/2023] Open
Abstract
Introduction: Diabetes mellitus is recognised as a significant risk factor for cardiovascular and peripheral vascular disease, as the abnormal metabolic state increases the risk for atherosclerosis, occlusive arterial disease and vascular dysfunction. There have been reports of potential association across the literature that illustrates a link between diabetes mellitus and aortic aneurysm, with the former having a protective role on the development of the latter. Methods: A thorough literature search was performed through electronic databases, to provide a comprehensive review of the study's reporting on the association of diabetes mellitus and aortic aneurysm, discussing the mechanisms that have been reported; furthemore, we reviewed the reports of the impact of oral hypoglycameic agents on aortic aneurysms. Results: Various proposed mechanisms are involved in this protective process including endothelial dysfunction, chronic hyperglycemia and insulin resistance. The evidence suggests a negative association between these disease process, with prevelance of diabetes mellitus resulting in lower rates of aortic aneurysm, via its protective mechanistic action. The increase in advanced glycation end products, increased arterial stiffness and vascular remodelling seen in diabetes, was found to have a profound impact on aneurysm development, its slow progression and lower rupture rate in these individuals. This review has also highlighted the role of oral hypoglycaemic agents having a protective effect against AA disease. Conclusion: A decrease in development, progression and mortality from aortic aneurysms as well as reduced rates of dissection, have been observed in those with diabetes. This review has provided a comprehensive insight on the effect of diabetes and its physiological processes, and elements of its con-committant treatment, having a protective role against these aortic diseases.
Collapse
Affiliation(s)
- Divyatha Arun
- Department of Endocrinology, Columbia Asia Referral Hospital, A Unit of Manipal Hospital, Yeshwanthpur, Bengaluru, India
| | - Wahaj Munir
- Barts and the London School of Medicine and Dentistry, Queen Mary University of London, London, United Kingdom
| | - Lara Victoria Schmitt
- Barts and the London School of Medicine and Dentistry, Queen Mary University of London, London, United Kingdom
| | - Rohan Vyas
- Barts and the London School of Medicine and Dentistry, Queen Mary University of London, London, United Kingdom
| | - Jeuela Iris Ravindran
- Barts and the London School of Medicine and Dentistry, Queen Mary University of London, London, United Kingdom
| | - Mohamad Bashir
- Institue of Cardiac and Aortic Disorders, SRM Institutes for Medical Science (SIMS Hospitals), Chennai, India
| | | | - Bashi Velayudhan
- Institue of Cardiac and Aortic Disorders, SRM Institutes for Medical Science (SIMS Hospitals), Chennai, India
| | - Mohammed Idhrees
- Institue of Cardiac and Aortic Disorders, SRM Institutes for Medical Science (SIMS Hospitals), Chennai, India
| |
Collapse
|
12
|
Vascular Deformation Mapping of Abdominal Aortic Aneurysm. ACTA ACUST UNITED AC 2021; 7:189-201. [PMID: 34067962 PMCID: PMC8162544 DOI: 10.3390/tomography7020017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Revised: 04/23/2021] [Accepted: 05/10/2021] [Indexed: 12/01/2022]
Abstract
Abdominal aortic aneurysm (AAA) is a complex disease that requires regular imaging surveillance to monitor for aneurysm stability. Current imaging surveillance techniques use maximum diameter, often assessed by computed tomography angiography (CTA), to assess risk of rupture and determine candidacy for operative repair. However, maximum diameter measurements can be variable, do not reliably predict rupture risk and future AAA growth, and may be an oversimplification of complex AAA anatomy. Vascular deformation mapping (VDM) is a recently described technique that uses deformable image registration to quantify three-dimensional changes in aortic wall geometry, which has been previously used to quantify three-dimensional (3D) growth in thoracic aortic aneurysms, but the feasibility of the VDM technique for measuring 3D growth in AAA has not yet been studied. Seven patients with infra-renal AAAs were identified and VDM was used to identify three-dimensional maps of AAA growth. In the present study, we demonstrate that VDM is able to successfully identify and quantify 3D growth (and the lack thereof) in AAAs that is not apparent from maximum diameter. Furthermore, VDM can be used to quantify growth of the excluded aneurysm sac after endovascular aneurysm repair (EVAR). VDM may be a useful adjunct for surgical planning and appears to be a sensitive modality for detecting regional growth of AAAs.
Collapse
|
13
|
In Vivo Aortic Magnetic Resonance Elastography in Abdominal Aortic Aneurysm: A Validation in an Animal Model. Invest Radiol 2021; 55:463-472. [PMID: 32520516 DOI: 10.1097/rli.0000000000000660] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
OBJECTIVES Using maximum diameter of an abdominal aortic aneurysm (AAA) alone for management can lead to delayed interventions or unnecessary urgent repairs. Abdominal aortic aneurysm stiffness plays an important role in its expansion and rupture. In vivo aortic magnetic resonance elastography (MRE) was developed to spatially measure AAA stiffness in previous pilot studies and has not been thoroughly validated and evaluated for its potential clinical value. This study aims to evaluate noninvasive in vivo aortic MRE-derived stiffness in an AAA porcine model and investigate the relationships between MRE-derived AAA stiffness and (1) histopathology, (2) uniaxial tensile test, and (3) burst testing for assessing MRE's potential in evaluating AAA rupture risk. MATERIALS AND METHODS Abdominal aortic aneurysm was induced in 31 Yorkshire pigs (n = 226 stiffness measurements). Animals were randomly divided into 3 cohorts: 2-week, 4-week, and 4-week-burst. Aortic MRE was sequentially performed. Histopathologic analyses were performed to quantify elastin, collagen, and mineral densities. Uniaxial tensile test and burst testing were conducted to measure peak stress and burst pressure for assessing the ultimate wall strength. RESULTS Magnetic resonance elastography-derived AAA stiffness was significantly higher than the normal aorta. Significant reduction in elastin and collagen densities as well as increased mineralization was observed in AAAs. Uniaxial tensile test and burst testing revealed reduced ultimate wall strength. Magnetic resonance elastography-derived aortic stiffness correlated to elastin density (ρ = -0.68; P < 0.0001; n = 60) and mineralization (ρ = 0.59; P < 0.0001; n = 60). Inverse correlations were observed between aortic stiffness and peak stress (ρ = -0.32; P = 0.0495; n = 38) as well as burst pressure (ρ = -0.55; P = 0.0116; n = 20). CONCLUSIONS Noninvasive in vivo aortic MRE successfully detected aortic wall stiffening, confirming the extracellular matrix remodeling observed in the histopathologic analyses. These mural changes diminished wall strength. Inverse correlation between MRE-derived aortic stiffness and aortic wall strength suggests that MRE-derived stiffness can be a potential biomarker for clinically assessing AAA wall status and rupture potential.
Collapse
|
14
|
Chong MY, Gu B, Chan BT, Ong ZC, Xu XY, Lim E. Effect of intimal flap motion on flow in acute type B aortic dissection by using fluid-structure interaction. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2020; 36:e3399. [PMID: 32862487 DOI: 10.1002/cnm.3399] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2020] [Revised: 08/18/2020] [Accepted: 08/25/2020] [Indexed: 06/11/2023]
Abstract
A monolithic, fully coupled fluid-structure interaction (FSI) computational framework was developed to account for dissection flap motion in acute type B aortic dissection (TBAD). Analysis of results included wall deformation, pressure, flow, wall shear stress (WSS), von Mises stress and comparison of hemodynamics between rigid wall and FSI models. Our FSI model mimicked realistic wall deformation that resulted in maximum compression of the distal true lumen (TL) by 21.4%. The substantial movement of intimal flap mostly affected flow conditions in the false lumen (FL). Flap motion facilitated more flow entering the FL at peak systole, with the TL to FL flow split changing from 88:12 in the rigid model to 83:17 in the FSI model. There was more disturbed flow in the FL during systole (5.8% FSI vs 5.2% rigid) and diastole (13.5% FSI vs 9.8% rigid), via a λ2 -criterion. The flap-induced disturbed flow near the tears in the FSI model caused an increase of local WSS by up to 70.0% during diastole. This resulted in a significant reduction in the size of low time-averaged WSS (TAWSS) regions in the FL (113.11 cm2 FSI vs 177.44 cm2 rigid). Moreover, the FSI model predicted lower systolic pressure, higher diastolic pressure, and hence lower pulse pressure. Our results provided new insights into the possible impact of flap motion on flow in aortic dissections, which are particularly important when evaluating hemodynamics of acute TBAD. NOVELTY STATEMENT: Our monolithic fully coupled FSI computational framework is able to reproduce experimentally measured range of flap deformation in aortic dissection, thereby providing novel insights into the influence of physiological flap motion on the flow and pressure distributions. The drastic flap movement increases the flow resistance in the true lumen and causes more disturbed flow in the false lumen, as visualized through the λ2 criterion. The flap-induced luminal pressure is dampened, thereby affecting pressure measures, which may serve as potential prognostic indicators for late complications in acute uncomplicated TBAD patients.
Collapse
Affiliation(s)
- Mei Yan Chong
- Department of Biomedical Engineering, University of Malaya, Kuala Lumpur, Malaysia
- Department of Chemical Engineering, Imperial College London, London, UK
| | - Boram Gu
- Department of Chemical Engineering, Imperial College London, London, UK
| | - Bee Ting Chan
- Department of Mechanical, Materials and Manufacturing Engineering, University of Nottingham, Nottingham, UK
| | - Zhi Chao Ong
- Department of Mechanical Engineering, University of Malaya, Kuala Lumpur, Malaysia
| | - Xiao Yun Xu
- Department of Chemical Engineering, Imperial College London, London, UK
| | - Einly Lim
- Department of Biomedical Engineering, University of Malaya, Kuala Lumpur, Malaysia
| |
Collapse
|
15
|
Lane BA, Wang X, Lessner SM, Vyavahare NR, Eberth JF. Targeted Gold Nanoparticles as an Indicator of Mechanical Damage in an Elastase Model of Aortic Aneurysm. Ann Biomed Eng 2020; 48:2268-2278. [PMID: 32240423 DOI: 10.1007/s10439-020-02500-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2019] [Accepted: 03/27/2020] [Indexed: 12/23/2022]
Abstract
Elastin is a key structural protein and its pathological degradation deterministic in aortic aneurysm (AA) outcomes. Unfortunately, using current diagnostic and clinical surveillance techniques the integrity of the elastic fiber network can only be assessed invasively. To address this, we employed fragmented elastin-targeting gold nanoparticles (EL-AuNPs) as a diagnostic tool for the evaluation of unruptured AAs. Electron dense EL-AuNPs were visualized within AAs using micro-computed tomography (micro-CT) and the corresponding Gold-to-Tissue volume ratios quantified. The Gold-to-Tissue volume ratios correlated strongly with the concentration (0, 0.5, or 10 U/mL) of infused porcine pancreatic elastase and therefore the degree of elastin damage. Hyperspectral mapping confirmed the spatial targeting of the EL-AuNPs to the sites of damaged elastin. Nonparametric Spearman's rank correlation indicated that the micro-CT-based Gold-to-Tissue volume ratios had a strong correlation with loaded (ρ = 0.867, p-val = 0.015) and unloaded (ρ = 0.830, p-val = 0.005) vessel diameter, percent dilation (ρ = 0.976, p-val = 0.015), circumferential stress (ρ = 0.673, p-val = 0.007), loaded (ρ = - 0.673, p-val = 0.017) and unloaded (ρ = - 0.697, p-val = 0.031) wall thicknesses, circumferential stretch (ρ = - 0.7234, p-val = 0.018), and lumen area compliance (ρ = - 0.831, p-val = 0.003). Likewise, in terms of axial force and axial stress vs. stretch, the post-elastase vessels were stiffer. Collectively, these findings suggest that, when combined with CT imaging, EL-AuNPs can be used as a powerful tool in the non-destructive estimation of mechanical and geometric features of AAs.
Collapse
Affiliation(s)
- Brooks A Lane
- Biomedical Engineering Program, University of South Carolina, Columbia, SC, 29208, USA
| | - Xiaoying Wang
- Bioengineering Department, Clemson University, Clemson, SC, USA
| | - Susan M Lessner
- Biomedical Engineering Program, University of South Carolina, Columbia, SC, 29208, USA.,Cell Biology and Anatomy Department, University of South Carolina, Columbia, SC, USA
| | | | - John F Eberth
- Biomedical Engineering Program, University of South Carolina, Columbia, SC, 29208, USA. .,Cell Biology and Anatomy Department, University of South Carolina, Columbia, SC, USA.
| |
Collapse
|
16
|
Romary DJ, Berman AG, Goergen CJ. High-frequency murine ultrasound provides enhanced metrics of BAPN-induced AAA growth. Am J Physiol Heart Circ Physiol 2019; 317:H981-H990. [PMID: 31559828 PMCID: PMC6879923 DOI: 10.1152/ajpheart.00300.2019] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/22/2019] [Revised: 09/11/2019] [Accepted: 09/18/2019] [Indexed: 12/12/2022]
Abstract
An abdominal aortic aneurysm (AAA), defined as a pathological expansion of the largest artery in the abdomen, is a common vascular disease that frequently leads to death if rupture occurs. Once diagnosed, clinicians typically evaluate the rupture risk based on maximum diameter of the aneurysm, a limited metric that is not accurate for all patients. In this study, we worked to evaluate additional distinguishing factors between growing and stable murine aneurysms toward the aim of eventually improving clinical rupture risk assessment. With the use of a relatively new mouse model that combines surgical application of topical elastase to cause initial aortic expansion and a lysyl oxidase inhibitor, β-aminopropionitrile (BAPN), in the drinking water, we were able to create large AAAs that expanded over 28 days. We further sought to develop and demonstrate applications of advanced imaging approaches, including four-dimensional ultrasound (4DUS), to evaluate alternative geometric and biomechanical parameters between 1) growing AAAs, 2) stable AAAs, and 3) nonaneurysmal control mice. Our study confirmed the reproducibility of this murine model and found reduced circumferential strain values, greater tortuosity, and increased elastin degradation in mice with aneurysms. We also found that expanding murine AAAs had increased peak wall stress and surface area per length compared with stable aneurysms. The results from this work provide clear growth patterns associated with BAPN-elastase murine aneurysms and demonstrate the capabilities of high-frequency ultrasound. These data could help lay the groundwork for improving insight into clinical prediction of AAA expansion.NEW & NOTEWORTHY This work characterizes a relatively new murine model of abdominal aortic aneurysms (AAAs) by quantifying vascular strain, stress, and geometry. Furthermore, Green-Lagrange strain was calculated with a novel mapping approach using four-dimensional ultrasound. We also compared growing and stable AAAs, finding peak wall stress and surface area per length to be most indicative of growth. In all AAAs, strain and elastin health declined, whereas tortuosity increased.
Collapse
MESH Headings
- Aminopropionitrile
- Animals
- Aorta, Abdominal/diagnostic imaging
- Aorta, Abdominal/pathology
- Aorta, Abdominal/physiopathology
- Aortic Aneurysm, Abdominal/chemically induced
- Aortic Aneurysm, Abdominal/diagnostic imaging
- Aortic Aneurysm, Abdominal/pathology
- Aortic Aneurysm, Abdominal/physiopathology
- Biomechanical Phenomena
- Dilatation, Pathologic
- Disease Models, Animal
- Disease Progression
- Hemodynamics
- Male
- Mice, Inbred C57BL
- Pancreatic Elastase
- Predictive Value of Tests
- Stress, Mechanical
- Time Factors
- Ultrasonography
- Vascular Remodeling
Collapse
Affiliation(s)
- Daniel J Romary
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana
| | - Alycia G Berman
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana
| | - Craig J Goergen
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana
- Purdue Center for Cancer Research, Purdue University, West Lafayette, Indiana
| |
Collapse
|
17
|
Sahutoglu T, Artim Esen B, Aksoy M, Kurtoglu M, Poyanli A, Gul A. Clinical course of abdominal aortic aneurysms in Behçet disease: a retrospective analysis. Rheumatol Int 2019; 39:1061-1067. [PMID: 30888471 DOI: 10.1007/s00296-019-04283-y] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Accepted: 03/13/2019] [Indexed: 12/29/2022]
Abstract
Arterial aneurysms are rare manifestations of Behçet Disease (BD) with high morbidity and mortality. This study aimed to investigate the clinical course of BD patients with abdominal aortic aneurysms (AAA). We retrospectively searched charts of BD patients, followed up between 1988 and 2011, to identify those with AAA with at least 6-month clinical and radiological follow-up data. Chart review revealed 12 patients (11 males) with AAA amongst 1224 patients; follow-up data from 11 patients were available. The most common symptoms were lower back and abdominal pain. The only pre-treatment complication was a spontaneous rupture. All but one patient received corticosteroid and cyclophosphamide pulses for the induction, and corticosteroid and azathioprine for the maintenance treatment; one patient received only the maintenance treatment. Two patients had surgical graft interposition, without postoperative complications. Seven patients had endovascular stenting; five of them (71.4%) showed radiological regression after 32.5 (13.4-53.8) months, while four (57%) had clinical improvement after 11.8 (0.2-29.4) months. However, one non-responsive patient developed stent infection and exsanguinated during percutaneous drainage, and one patient developed femoral artery pseudo-aneurysm at the catheter insertion site. Another patient developed a new aneurysm under the maintenance treatment. Medical treatment alone yielded radiological regression in one of two patients. Current immunosuppressive, surgical or endovascular approaches can provide clinical and radiological improvements lately in BD patients with AAA. Furthermore, complication rates seem to be high with interventional approaches. These findings suggest an unmet need for safer alternative treatments.
Collapse
Affiliation(s)
- Tuncay Sahutoglu
- Division of Rheumatology, Department of Internal Medicine, Istanbul Faculty of Medicine, Istanbul University, Fatih, 34093, Istanbul, Turkey
- Department of Nephrology, Sanliurfa Mehmet Akif Inan Training and Research Hospital, Health Sciences University, Urfa, Turkey
| | - Bahar Artim Esen
- Division of Rheumatology, Department of Internal Medicine, Istanbul Faculty of Medicine, Istanbul University, Fatih, 34093, Istanbul, Turkey
| | - Murat Aksoy
- Division of Vascular Surgery, Department of Surgery, Istanbul University, Istanbul, Turkey
| | - Mehmet Kurtoglu
- Division of Vascular Surgery, Department of Surgery, Istanbul University, Istanbul, Turkey
| | - Arzu Poyanli
- Department of Radiology, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey
| | - Ahmet Gul
- Division of Rheumatology, Department of Internal Medicine, Istanbul Faculty of Medicine, Istanbul University, Fatih, 34093, Istanbul, Turkey.
| |
Collapse
|
18
|
Helthuis JHG, Bhat S, van Doormaal TPC, Kumar RK, van der Zwan A. Proximal and Distal Occlusion of Complex Cerebral Aneurysms-Implications of Flow Modeling by Fluid-Structure Interaction Analysis. Oper Neurosurg (Hagerstown) 2018; 15:217-230. [PMID: 29281095 DOI: 10.1093/ons/opx236] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2017] [Accepted: 10/10/2017] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND In complex cerebral aneurysms, adequate treatment by complete occlusion is not always possible. Partial occlusion by either proximal or distal occlusion is an alternative. However, the hemodynamic consequences of these partial occlusion options are often not easily predictable. OBJECTIVE To assess the feasibility of fluid-structure interaction (FSI) analysis to investigate the hemodynamic changes after partial occlusion in cerebral aneurysms. METHODS Two patients were analyzed. One was treated by proximal occlusion and 1 by distal occlusion. In both, flow replacement bypass surgery was performed. Three-dimensional models were constructed from magnetic resonance angiography (MRA) scans and used for FSI analysis. A comparative study was done for pre- and postoperative conditions. Postoperative thrombosis was modeled and analyzed for the distal occlusion. FSI results were compared to postoperative angiograms and computed tomography (CT)-scans. RESULTS Proximal occlusion resulted in reduction of velocity, wall shear stresses, and disappearance of helical flow patterns in the complete aneurysm. Distal occlusion showed a decrease of velocity and wall shear stress in the dome of the aneurysm. Results were validated against postoperative CT-scans and angiograms at 1-, 7-, and 9-mo follow-up. Addition of thrombus to the distal occlusion model showed no change in velocities and luminal pressure but resulted in decrease in wall tension. CONCLUSION This pilot study showed hemodynamic changes in 2 patients with proximal and distal occlusion of complex cerebral aneurysms. The FSI results were in line with the follow-up CT scans and angiograms and indicate the potential of FSI as a tool in patient-specific surgical interventions.
Collapse
Affiliation(s)
- Jasper H G Helthuis
- Department of Neurology and Neuro-surgery, Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, The Netherlands.,Brain Technology Institute, Utrecht, The Netherlands
| | - Sindhoor Bhat
- Department of Engineering Design, Indian Institute of Technology Madras, Chennai, India
| | - Tristan P C van Doormaal
- Department of Neurology and Neuro-surgery, Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, The Netherlands.,Brain Technology Institute, Utrecht, The Netherlands
| | | | - Albert van der Zwan
- Department of Neurology and Neuro-surgery, Brain Center Rudolf Magnus, University Medical Center Utrecht, Utrecht, The Netherlands.,Brain Technology Institute, Utrecht, The Netherlands
| |
Collapse
|
19
|
Seto SW, Chang D, Kiat H, Wang N, Bensoussan A. Chinese Herbal Medicine as a Potential Treatment of Abdominal Aortic Aneurysm. Front Cardiovasc Med 2018; 5:33. [PMID: 29732374 PMCID: PMC5919947 DOI: 10.3389/fcvm.2018.00033] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2017] [Accepted: 03/20/2018] [Indexed: 12/19/2022] Open
Abstract
Abdominal aortic aneurysm (AAA) is an irreversible condition where the abdominal aorta is dilated leading to potentially fatal consequence of aortic rupture. Multiple mechanisms are involved in the development and progression of AAA, including chronic inflammation, oxidative stress, vascular smooth muscle (VSMC) apoptosis, immune cell infiltration and extracellular matrix (ECM) degradation. Currently surgical therapies, including minimally invasive endovascular aneurysm repair (EVAR), are the only viable interventions for AAAs. However, these treatments are not appropriate for the majority of AAAs, which measure <50 mm. Substantial effort has been invested to identify and develop pharmaceutical treatments such as statins and doxycycline for this potentially lethal condition but these interventions failed to offer a cure or to retard the progression of AAA. Chinese herbal medicine (CHM) has been used for the management of cardiovascular diseases for thousands of years in China and other Asian countries. The unique multi-component and multi-target property of CHMs makes it a potentially ideal therapy for multifactorial diseases such as AAA. In this review, we review the current scientific evidence to support the use of CHMs for the treatment of AAA. Mechanisms of action underlying the effects of CHMs on AAA are also discussed.
Collapse
Affiliation(s)
- Sai Wang Seto
- NICM Health Research Institute, Western Sydney University, Penrith, Australia
| | - Dennis Chang
- NICM Health Research Institute, Western Sydney University, Penrith, Australia
| | - Hosen Kiat
- Faculty of Medicine, University of New South Wales, Sydney, Australia.,School of Medicine, Western Sydney University, Penrith, Australia.,Faculty of Medicine and Health Sciences, Macquarie University, Sydney, Australia
| | - Ning Wang
- NICM Health Research Institute, Western Sydney University, Penrith, Australia.,Key Laboratory of Xin'an Medicine, Ministry of Education, Hefei, China.,College of Pharmacy, Anhui University of Chinese Medicine, Hefei, China.,Institute for Pharmacodynamics and Safety Evaluation of Chinese Medicine, Anhui University of Chinese Medicine, Hefei, China
| | - Alan Bensoussan
- NICM Health Research Institute, Western Sydney University, Penrith, Australia
| |
Collapse
|
20
|
Haslach HW, Siddiqui A, Weerasooriya A, Nguyen R, Roshgadol J, Monforte N, McMahon E. Fracture mechanics of shear crack propagation and dissection in the healthy bovine descending aortic media. Acta Biomater 2018; 68:53-66. [PMID: 29292167 DOI: 10.1016/j.actbio.2017.12.027] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2017] [Revised: 12/06/2017] [Accepted: 12/19/2017] [Indexed: 11/24/2022]
Abstract
This experimental study adopts a fracture mechanics strategy to investigate the mechanical cause of aortic dissection. Inflation of excised healthy bovine aortic rings with a cut longitudinal notch that extends into the media from the intima suggests that an intimal tear may propagate a nearly circumferential-longitudinal rupture surface that is similar to the delamination that occurs in aortic dissection. Radial and 45°-from-radial cut notch orientations, as seen in the thickness surface, produce similar circumferential crack propagation morphologies. Partial cut notches, whose longitudinal length is half the width of the ring, measure the influence of longitudinal material on crack propagation. Such specimens also produce circumferential cracks from the notch root that are visible in the thickness circumferential-radial plane, and often propagate a secondary crack from the base of the notch, visible in the intimal circumferential-longitudinal plane. Inflation of rings with pairs of cut notches demonstrates that a second notch modifies the propagation created in a specimen with a single notch. The circumferential crack propagation is likely a consequence of the laminar medial structure. These fracture surfaces are probably due to non-uniform circumferential shear deformation in the heterogeneous media as the aortic wall expands. The qualitative deformation morphology around the root of the cut notch during inflation is evidence for such shear deformation. The shear apparently results from relative slip in the circumferential direction of collagen fibers. The slip may produce shear in the longitudinal-circumferential plane between medial layers or in the radial-circumferential plane within a medial lamina in an idealized model. Circumferential crack propagation in the media is then a shear mechanical process that might be facilitated by disease of the tissue. STATEMENT OF SIGNIFICANCE An intimal tear of an apparently healthy aortic wall near the aortic arch is life-threatening because it may lead to full rupture or to wall dissection in which delamination of the medial layer extends around most of the aortic circumference. The mechanical events underlying dissection are not definitively established. This experimental fracture mechanics study provides evidence that shear rupture is the main mechanical process underlying aortic dissection. The commonly performed tensile strength tests of aortic tissue are not clinically useful to predict or describe aortic dissection. One implication of the study is that shear tests might produce more fruitful simple assessments of the aortic wall strength. A clinical implication is that when presented with an intimal tear, those who guide care might recommend steps to reduce the shear load on the aorta.
Collapse
|
21
|
The Society for Vascular Surgery practice guidelines on the care of patients with an abdominal aortic aneurysm. J Vasc Surg 2018; 67:2-77.e2. [DOI: 10.1016/j.jvs.2017.10.044] [Citation(s) in RCA: 1765] [Impact Index Per Article: 252.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
22
|
Kemmerling EMC, Peattie RA. Abdominal Aortic Aneurysm Pathomechanics: Current Understanding and Future Directions. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2018; 1097:157-179. [DOI: 10.1007/978-3-319-96445-4_8] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
23
|
Lin JM, Patterson AJ, Chao TC, Zhu C, Chang HC, Mendes J, Chung HW, Gillard JH, Graves MJ. Free-breathing black-blood CINE fast-spin echo imaging for measuring abdominal aortic wall distensibility: a feasibility study. Phys Med Biol 2017; 62:N204-N218. [PMID: 28327475 DOI: 10.1088/1361-6560/aa685a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
The paper reports a free-breathing black-blood CINE fast-spin echo (FSE) technique for measuring abdominal aortic wall motion. The free-breathing CINE FSE includes the following MR techniques: (1) variable-density sampling with fast iterative reconstruction; (2) inner-volume imaging; and (3) a blood-suppression preparation pulse. The proposed technique was evaluated in eight healthy subjects. The inner-volume imaging significantly reduced the intraluminal artifacts of respiratory motion (p = 0.015). The quantitative measurements were a diameter of 16.3 ± 2.8 mm and wall distensibility of 2.0 ± 0.4 mm (12.5 ± 3.4%) and 0.7 ± 0.3 mm (4.1 ± 1.0%) for the anterior and posterior walls, respectively. The cyclic cross-sectional distensibility was 35 ± 15% greater in the systolic phase than in the diastolic phase. In conclusion, we developed a feasible CINE FSE method to measure the motion of the abdominal aortic wall, which will enable clinical scientists to study the elasticity of the abdominal aorta.
Collapse
Affiliation(s)
- Jyh-Miin Lin
- Department of Radiology, University of Cambridge, Cambridge, CB2 0QQ, United Kingdom. Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan
| | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Fluid-Structure Interaction in Abdominal Aortic Aneurysm: Effect of Modeling Techniques. BIOMED RESEARCH INTERNATIONAL 2017; 2017:7023078. [PMID: 28321413 PMCID: PMC5340988 DOI: 10.1155/2017/7023078] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/10/2016] [Revised: 12/07/2016] [Accepted: 01/15/2017] [Indexed: 11/17/2022]
Abstract
In this work, the impact of modeling techniques on predicting the mechanical behaviors of abdominal aortic aneurysm (AAA) is systematically investigated. The fluid-structure interaction (FSI) model for simultaneously capturing the transient interaction between blood flow dynamics and wall mechanics was compared with its simplified techniques, that is, computational fluid dynamics (CFD) or computational solid stress (CSS) model. Results demonstrated that CFD exhibited relatively smaller vortexes and tends to overestimate the fluid wall shear stress, compared to FSI. On the contrary, the minimal differences in wall stresses and deformation were observed between FSI and CSS models. Furthermore, it was found that the accuracy of CSS prediction depends on the applied pressure profile for the aneurysm sac. A large pressure drop across AAA usually led to the underestimation of wall stresses and thus the AAA rupture. Moreover, the assumed isotropic AAA wall properties, compared to the anisotropic one, will aggravate the difference between the simplified models with the FSI approach. The present work demonstrated the importance of modeling techniques on predicting the blood flow dynamics and wall mechanics of the AAA, which could guide the selection of appropriate modeling technique for significant clinical implications.
Collapse
|
25
|
Understanding the Pathophysiology of Portosystemic Shunt by Simulation Using an Electric Circuit. BIOMED RESEARCH INTERNATIONAL 2016; 2016:2097363. [PMID: 27868061 PMCID: PMC5102704 DOI: 10.1155/2016/2097363] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/03/2016] [Revised: 10/04/2016] [Accepted: 10/13/2016] [Indexed: 12/12/2022]
Abstract
Portosystemic shunt (PSS) without a definable cause is a rare condition, and most of the studies on this topic are small series or based on case reports. Moreover, no firm agreement has been reached on the definition and classification of various forms of PSS, which makes it difficult to compare and analyze the management. The blood flow can be seen very similar to an electric current, governed by Ohm's law. The simulation of PSS using an electric circuit, combined with the interpretation of reported management results, can provide intuitive insights into the underlying mechanism of PSS development. In this article, we have built a model of PSS using electric circuit symbols and explained clinical manifestations as well as the possible mechanisms underlying a PSS formation.
Collapse
|
26
|
Giannoglou G, Giannakoulas G, Soulis J, Chatzizisis Y, Perdikides T, Melas N, Parcharidis G, Louridas G. Predicting the Risk of Rupture of Abdominal Aortic Aneurysms by Utilizing Various Geometrical Parameters: Revisiting the Diameter Criterion. Angiology 2016; 57:487-94. [PMID: 17022385 DOI: 10.1177/0003319706290741] [Citation(s) in RCA: 57] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The authors estimated noninvasively the wall stress distribution for actual abdominal aortic aneurysms (AAAs) in vivo on a patient-to-patient basis and correlated the peak wall stress (PWS) with various geometrical parameters. They studied 39 patients (37 men, mean age 73.7 ± 8.2 years) with an intact AAA (mean diameter 6.3 ± 1.7 cm) undergoing preoperative evaluation with spiral computed tomography (CT). Real 3-dimensional AAA geometry was obtained from image processing. Wall stress was determined by using a finite-element analysis. The aorta was considered isotropic with linear material properties and was loaded with a static pressure of 120.0 mm Hg. Various geometrical parameters were used to characterize the AAAs. PWS and each of the geometrical characteristics were correlated by use of Pearson's rank correlation coefficients. PWS varied from 10.2 to 65.8 N/cm2 (mean value 37.1 ± 9.9 N/cm2). Among the geometrical parameters, the PWS was well correlated with the mean centerline curvature, the maximum centerline curvature, and the maximum centerline torsion of the AAAs. The correlation of PWS with maximum diameter was nonsignificant. Multiple regression analysis revealed that the mean centerline curvature of the AAA was the only significant predictor of PWS and subsequent rupture risk. This noninvasive computational approach showed that geometrical parameters other than the maximum diameter are better indicators of AAA rupture.
Collapse
Affiliation(s)
- G Giannoglou
- Cardiovascular Engineering and Atherosclerosis Laboratory, 1st Cardiology Department, AHEPA University Hospital, Medical School, Aristotle University of Thessaloniki, 1 St. Kyriakidi Str, 54637, Thessaloniki, Greece.
| | | | | | | | | | | | | | | |
Collapse
|
27
|
Indrakusuma R, Jalalzadeh H, Planken RN, Marquering HA, Legemate DA, Koelemay MJW, Balm R. Biomechanical Imaging Markers as Predictors of Abdominal Aortic Aneurysm Growth or Rupture: A Systematic Review. Eur J Vasc Endovasc Surg 2016; 52:475-486. [PMID: 27558090 DOI: 10.1016/j.ejvs.2016.07.003] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2016] [Accepted: 07/01/2016] [Indexed: 11/20/2022]
Abstract
OBJECTIVES Biomechanical characteristics, such as wall stress, are important in the pathogenesis of abdominal aortic aneurysms (AAA) and can be visualised and quantified using imaging techniques. This systematic review aims to present an overview of all biomechanical imaging markers that have been studied in relation to AAA growth and rupture. METHODS This systematic review followed the PRISMA guidelines. A search in Medline, Embase, and the Cochrane Library identified 1503 potentially relevant articles. Studies were included if they assessed biomechanical imaging markers and their potential association with growth or rupture. RESULTS Twenty-seven articles comprising 1730 patients met the inclusion criteria. Eighteen studies performed wall stress analysis using finite element analysis (FEA), 13 of which used peak wall stress (PWS) to quantify wall stress. Ten of 13 case control FEA studies reported a significantly higher PWS for symptomatic or ruptured AAAs than for intact AAAs. However, in some studies there was confounding bias because of baseline differences in aneurysm diameter between groups. Clinical heterogeneity in methodology obstructed a meaningful meta-analysis of PWS. Three of five FEA studies reported a significant positive association between several wall stress markers, such as PWS and 99th percentile stress, and growth. One study reported a significant negative association and one other study reported no significant association. Studies assessing wall compliance, the augmentation index and wall stress analysis using Laplace's law, computational fluid dynamics and fluid structure interaction were also included in this systematic review. CONCLUSIONS Although PWS is significantly higher in symptomatic or ruptured AAAs in most FEA studies, confounding bias, clinical heterogeneity, and lack of standardisation limit the interpretation and generalisability of the results. Also, there is conflicting evidence on whether increased wall stress is associated with growth.
Collapse
Affiliation(s)
- R Indrakusuma
- Department of Surgery, Academic Medical Center, Amsterdam, The Netherlands
| | - H Jalalzadeh
- Department of Surgery, Academic Medical Center, Amsterdam, The Netherlands
| | - R N Planken
- Department of Radiology, Academic Medical Center, Amsterdam, The Netherlands
| | - H A Marquering
- Department of Radiology, Academic Medical Center, Amsterdam, The Netherlands; Department of Biomedical Engineering and Physics, Academic Medical Center, Amsterdam, The Netherlands
| | - D A Legemate
- Department of Surgery, Academic Medical Center, Amsterdam, The Netherlands
| | - M J W Koelemay
- Department of Surgery, Academic Medical Center, Amsterdam, The Netherlands
| | - R Balm
- Department of Surgery, Academic Medical Center, Amsterdam, The Netherlands.
| |
Collapse
|
28
|
Li H, Lin K, Shahmirzadi D. FSI Simulations of Pulse Wave Propagation in Human Abdominal Aortic Aneurysm: The Effects of Sac Geometry and Stiffness. Biomed Eng Comput Biol 2016; 7:25-36. [PMID: 27478394 PMCID: PMC4951115 DOI: 10.4137/becb.s40094] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2016] [Revised: 06/28/2016] [Accepted: 07/02/2016] [Indexed: 11/21/2022] Open
Abstract
This study aims to quantify the effects of geometry and stiffness of aneurysms on the pulse wave velocity (PWV) and propagation in fluid–solid interaction (FSI) simulations of arterial pulsatile flow. Spatiotemporal maps of both the wall displacement and fluid velocity were generated in order to obtain the pulse wave propagation through fluid and solid media, and to examine the interactions between the two waves. The results indicate that the presence of abdominal aortic aneurysm (AAA) sac and variations in the sac modulus affect the propagation of the pulse waves both qualitatively (eg, patterns of change of forward and reflective waves) and quantitatively (eg, decreasing of PWV within the sac and its increase beyond the sac as the sac stiffness increases). The sac region is particularly identified on the spatiotemporal maps with a region of disruption in the wave propagation with multiple short-traveling forward/reflected waves, which is caused by the change in boundary conditions within the saccular region. The change in sac stiffness, however, is more pronounced on the wall displacement spatiotemporal maps compared to those of fluid velocity. We conclude that the existence of the sac can be identified based on the solid and fluid pulse waves, while the sac properties can also be estimated. This study demonstrates the initial findings in numerical simulations of FSI dynamics during arterial pulsations that can be used as reference for experimental and in vivo studies. Future studies are needed to demonstrate the feasibility of the method in identifying very mild sacs, which cannot be detected from medical imaging, where the material property degradation exists under early disease initiation.
Collapse
Affiliation(s)
- Han Li
- Department of Mechanical Engineering, Stevens Institute of Technology, Hoboken, NJ, USA
| | - Kexin Lin
- Department of Mechanical Engineering, Stevens Institute of Technology, Hoboken, NJ, USA
| | - Danial Shahmirzadi
- Department of Mechanical Engineering, Stevens Institute of Technology, Hoboken, NJ, USA
| |
Collapse
|
29
|
Lahoz C, Gracia CE, García LR, Montoya SB, Hernando ÁB, Heredero ÁF, Tembra MS, Velasco MB, Guijarro C, Ruiz EB, Pintó X, de Ceniga MV, Moñux Ducajú G. [Not Available]. CLINICA E INVESTIGACION EN ARTERIOSCLEROSIS : PUBLICACION OFICIAL DE LA SOCIEDAD ESPANOLA DE ARTERIOSCLEROSIS 2016; 28 Suppl 1:1-49. [PMID: 27107212 DOI: 10.1016/s0214-9168(16)30026-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Affiliation(s)
- Carlos Lahoz
- Unidad de Lípidos y Riesgo Vascular, Servicio de Medicina Interna, Hospital Carlos III, Madrid, España.
| | - Carlos Esteban Gracia
- Servicio de Angiología y Cirugía Vascular, Hospital Universitari Germans Trias i Pujol, Badalona, Barcelona, España
| | | | - Sergi Bellmunt Montoya
- Servicio de Angiología y Cirugía Vascular, Hospital de la Santa Creu i Sant Pau, Barcelona, España
| | - Ángel Brea Hernando
- Unidad de Lípidos, Servicio de Medicina Interna, Hospital San Pedro, Logroño, España
| | | | - Manuel Suárez Tembra
- Unidad de Lípidos y Riesgo Cardiovascular, Servicio de Medicina Interna, Hospital San Rafael, A Coruña, España
| | - Marta Botas Velasco
- Servicio de Angiología y Cirugía Vascular, Hospital de Cabueñes, Gijón, España
| | - Carlos Guijarro
- Consulta de Riesgo Vascular, Unidad de Medicina Interna, Hospital Universitario Fundación Alcorcón, Alcorcón, Madrid, España
| | - Esther Bravo Ruiz
- Servicio de Angiología y Cirugía Vascular, Hospital Universitario de Basurto, Bilbao, España
| | - Xavier Pintó
- Unidad de Riesgo Vascular, Servicio de Medicina Interna, Hospital Universitario de Bellvitge, L' Hospitalet de Llobregat, Barcelona, España
| | - Melina Vega de Ceniga
- Servicio de Angiología y Cirugía Vascular, Hospital de Galdakao-Usansolo, Vizcaya, España
| | | |
Collapse
|
30
|
Grant SW, Sperrin M, Carlson E, Chinai N, Ntais D, Hamilton M, Dunn G, Buchan I, Davies L, McCollum CN. Calculating when elective abdominal aortic aneurysm repair improves survival for individual patients: development of the Aneurysm Repair Decision Aid and economic evaluation. Health Technol Assess 2016; 19:1-154, v-vi. [PMID: 25924187 DOI: 10.3310/hta19320] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
BACKGROUND Abdominal aortic aneurysm (AAA) repair aims to prevent premature death from AAA rupture. Elective repair is currently recommended when AAA diameter reaches 5.5 cm (men) and 5.0 cm (women). Applying population-based indications may not be appropriate for individual patient decisions, as the optimal indication is likely to differ between patients based on age and comorbidities. OBJECTIVE To develop an Aneurysm Repair Decision Aid (ARDA) to indicate when elective AAA repair optimises survival for individual patients and to assess the cost-effectiveness and associated uncertainty of elective repair at the aneurysm diameter recommended by the ARDA compared with current practice. DATA SOURCES The UK Vascular Governance North West and National Vascular Database provided individual patient data to develop predictive models for perioperative mortality and survival. Data from published literature were used to model AAA growth and risk of rupture. The cost-effectiveness analysis used data from published literature and from local and national databases. METHODS A combination of systematic review methods and clinical registries were used to provide data to populate models and inform the structure of the ARDA. Discrete event simulation (DES) was used to model the patient journey from diagnosis to death and synthesised data were used to estimate patient outcomes and costs for elective repair at alternative aneurysm diameters. Eight patient clinical scenarios (vignettes) were used as exemplars. The DES structure was validated by clinical and statistical experts. The economic evaluation estimated costs, quality-adjusted life-years (QALYs) and incremental cost-effectiveness ratios (ICERs) from the NHS, social care provider and patient perspective over a lifetime horizon. Cost-effectiveness acceptability analyses and probabilistic sensitivity analyses explored uncertainty in the data and the value for money of ARDA-based decisions. The ARDA outcome measures include perioperative mortality risk, annual risk of rupture, 1-, 5- and 10-year survival, postoperative long-term survival, median life expectancy and predicted time to current threshold for aneurysm repair. The primary economic measure was the ICER using the QALY as the measure of health benefit. RESULTS The analysis demonstrated it is feasible to build and run a complex clinical decision aid using DES. The model results support current guidelines for most vignettes but suggest that earlier repair may be effective in younger, fitter patients and ongoing surveillance may be effective in elderly patients with comorbidities. The model adds information to support decisions for patients with aneurysms outside current indications. The economic evaluation suggests that using the ARDA compared with current guidelines could be cost-effective but there is a high level of uncertainty. LIMITATIONS Lack of high-quality long-term data to populate all sections of the model meant that there is high uncertainty about the long-term clinical and economic consequences of repair. Modelling assumptions were necessary and the developed survival models require external validation. CONCLUSIONS The ARDA provides detailed information on the potential consequences of AAA repair or a decision not to repair that may be helpful to vascular surgeons and their patients in reaching informed decisions. Further research is required to reduce uncertainty about key data, including reintervention following AAA repair, and assess the acceptability and feasibility of the ARDA for use in routine clinical practice. FUNDING The National Institute for Health Research Health Technology Assessment programme.
Collapse
Affiliation(s)
- Stuart W Grant
- Institute of Cardiovascular Sciences, University of Manchester, Manchester, UK
| | - Matthew Sperrin
- Institute of Population Health, University of Manchester, Manchester, UK
| | - Eric Carlson
- Institute of Cardiovascular Sciences, University of Manchester, Manchester, UK
| | - Natasha Chinai
- Institute of Cardiovascular Sciences, University of Manchester, Manchester, UK
| | - Dionysios Ntais
- Institute of Population Health, University of Manchester, Manchester, UK
| | - Matthew Hamilton
- Institute of Population Health, University of Manchester, Manchester, UK
| | - Graham Dunn
- Institute of Population Health, University of Manchester, Manchester, UK
| | - Iain Buchan
- Institute of Population Health, University of Manchester, Manchester, UK
| | - Linda Davies
- Institute of Population Health, University of Manchester, Manchester, UK
| | - Charles N McCollum
- Institute of Cardiovascular Sciences, University of Manchester, Manchester, UK
| |
Collapse
|
31
|
Effects of arterial blood flow on walls of the abdominal aorta: distributions of wall shear stress and oscillatory shear index determined by phase-contrast magnetic resonance imaging. Heart Vessels 2015; 31:1168-75. [PMID: 26481791 DOI: 10.1007/s00380-015-0758-x] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/24/2014] [Accepted: 10/02/2015] [Indexed: 01/07/2023]
Abstract
Although abdominal aortic aneurysms (AAAs) occur mostly inferior to the renal artery, the mechanism of the development of AAA in relation to its specific location is not yet clearly understood. The objective of this study was to evaluate the hypothesis that even healthy volunteers may manifest specific flow characteristics of blood flow and alter wall shear or oscillatory shear stress in the areas where AAAs commonly develop. Eight healthy male volunteers were enrolled in this prospective study, aged from 24 to 27. Phase-contrast magnetic resonance imaging (MRI) was performed with electrocardiographic triggering. Flow-sensitive four-dimensional MR imaging of the abdominal aorta, with three-directional velocity encoding, including simple morphological image acquisition, was performed. Information on specific locations on the aortic wall was applied to the flow encodes to calculate wall shear stress (WSS) and oscillatory shear index (OSI). While time-framed WSS showed the highest peak of 1.14 ± 0.25 Pa in the juxtaposition of the renal artery, the WSS plateaued to 0.61 Pa at the anterior wall of the abdominal aorta. The OSI peaked distal to the renal arteries at the posterior wall of the abdominal aorta of 0.249 ± 0.148, and was constantly elevated in the whole abdominal aorta at more than 0.14. All subjects were found to have elevated OSI in regions where AAAs commonly occur. These findings indicate that areas of constant peaked oscillatory shear stress in the infra-renal aorta may be one of the factors that lead to morphological changes over time, even in healthy individuals.
Collapse
|
32
|
Sultan S, Hynes N, Kavanagh EP, Diethrich EB. How does the multilayer flow modulator work? The science behind the technical innovation. J Endovasc Ther 2015; 21:814-21. [PMID: 25453884 DOI: 10.1583/14-4858.1] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Affiliation(s)
- Sherif Sultan
- 1 Western Vascular Institute and the Department of Vascular and Endovascular Surgery, University College Hospital Galway, Ireland
| | | | | | | |
Collapse
|
33
|
Teng Z, Feng J, Zhang Y, Huang Y, Sutcliffe MPF, Brown AJ, Jing Z, Gillard JH, Lu Q. Layer- and Direction-Specific Material Properties, Extreme Extensibility and Ultimate Material Strength of Human Abdominal Aorta and Aneurysm: A Uniaxial Extension Study. Ann Biomed Eng 2015; 43:2745-59. [PMID: 25905688 PMCID: PMC4611020 DOI: 10.1007/s10439-015-1323-6] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2014] [Accepted: 04/12/2015] [Indexed: 11/26/2022]
Abstract
Mechanical analysis has the potential to provide complementary information to aneurysm morphology in assessing its vulnerability. Reliable calculations require accurate material properties of individual aneurysmal components. Quantification of extreme extensibility and ultimate material strength of the tissue are important if rupture is to be modelled. Tissue pieces from 11 abdomen aortic aneurysm (AAA) from patients scheduled for elective surgery and from 8 normal aortic artery (NAA) from patients who scheduled for kidney/liver transplant were collected at surgery and banked in liquid nitrogen with the use of Cryoprotectant solution to minimize frozen damage. Prior to testing, specimen were thawed and longitudinal and circumferential tissue strips were cut from each piece and adventitia, media and thrombus if presented were isolated for the material test. The incremental Young’s modulus of adventitia of NAA was direction-dependent at low stretch levels, but not the media. Both adventitia and media had a similar extreme extensibility in the circumferential direction, but the adventitia was much stronger. For aneurysmal tissues, no significant differences were found when the incremental moduli of adventitia, media or thrombus in both directions were compared. Adventitia and media from AAA had similar extreme extensibility and ultimate strength in both directions and thrombus was the weakest material. Adventitia and media from AAA were less extensible compared with those of NAA, but the ultimate strength remained similar. The material properties, including extreme extensibility and ultimate strength, of both healthy aortic and aneurysmal tissues were layer-dependent, but not direction-dependent.
Collapse
Affiliation(s)
- Zhongzhao Teng
- Department of Radiology, School of Clinical Medicine, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK.
- Department of Engineering, University of Cambridge, Cambridge, UK.
| | - Jiaxuan Feng
- Department of Vascular Surgery, Changhai Hospital, 168 Changhai Rd., Shanghai, 200433, China
| | - Yongxue Zhang
- Department of Radiology, School of Clinical Medicine, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
- Department of Vascular Surgery, Changhai Hospital, 168 Changhai Rd., Shanghai, 200433, China
| | - Yuan Huang
- Department of Radiology, School of Clinical Medicine, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
| | | | - Adam J Brown
- Division of Cardiovascular Medicine, University of Cambridge, Cambridge, UK
| | - Zaiping Jing
- Department of Vascular Surgery, Changhai Hospital, 168 Changhai Rd., Shanghai, 200433, China
| | - Jonathan H Gillard
- Department of Radiology, School of Clinical Medicine, University of Cambridge, Cambridge Biomedical Campus, Box 218, Cambridge, CB2 0QQ, UK
| | - Qingsheng Lu
- Department of Vascular Surgery, Changhai Hospital, 168 Changhai Rd., Shanghai, 200433, China.
| |
Collapse
|
34
|
Incidence of small abdominal aortic aneurysms rupture, impact of comorbidities and our experience with rupture risk prediction based on wall stress assessment. COR ET VASA 2015. [DOI: 10.1016/j.crvasa.2015.02.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
35
|
Roselli EE, Loor G, He J, Rafael AE, Rajeswaran J, Houghtaling PL, Svensson LG, Blackstone EH, Lytle BW. Distal aortic interventions after repair of ascending dissection: The argument for a more aggressive approach. J Thorac Cardiovasc Surg 2015; 149:S117-24.e3. [DOI: 10.1016/j.jtcvs.2014.11.029] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/24/2014] [Revised: 11/01/2014] [Accepted: 11/07/2014] [Indexed: 12/27/2022]
|
36
|
Kari FA, Kocher N, Beyersdorf F, Tscheuschler A, Meffert P, Rylski B, Siepe M, Russe MF, Hope MD. Four-dimensional magnetic resonance imaging-derived ascending aortic flow eccentricity and flow compression are linked to aneurysm morphology†. Interact Cardiovasc Thorac Surg 2015; 20:582-7; discussion 587-8. [PMID: 25636325 DOI: 10.1093/icvts/ivu446] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2014] [Accepted: 11/20/2014] [Indexed: 11/12/2022] Open
Abstract
OBJECTIVES The impact of specific blood flow patterns within ascending aortic and/or aortic root aneurysms on aortic morphology is unknown. We investigated the interrelation of ascending aortic flow compression/peripheralization and aneurysm morphology with respect to sinotubuar junction (STJ) definition. METHODS Thirty-one patients (aortic root/ascending aortic aneurysm >45 mm) underwent flow-sensitive 4D magnetic resonance thoracic aortic flow measurement at 3 Tesla (Siemens, Germany) at two different institutions (Freiburg, Germany, and San Francisco, CA, USA). Time-resolved image data post-processing and visualization of mid-systolic, mid-ascending aortic flow were performed using local vector fields. The Flow Compression Index (FCI) was calculated individually as a fraction of the area of high-velocity mid-systolic flow over the complete cross-sectional ascending aortic area. According to aortic aneurysm morphology, patients were grouped as (i) small root, eccentric ascending aortic aneurysm (STJ definition) and (ii) enlarged aortic root, non-eccentric ascending aortic aneurysm with diffuse root and tubular enlargement. RESULTS The mean FCI over all patients was 0.47 ± 0.5 (0.37-0.99). High levels of flow compression/peripheralization (FCI <0.6) were linked to eccentric aneurysm morphology (Group A, n = 11), while low levels or absence of aortic flow compression/peripheralization (FCI >0.8) occurred more often in Group B (n = 20). The FCI was 0.48 ± 0.05 in Group A and 0.78 ± 0.14 in Group B (P < 0.001). Distribution of bicuspid aortic valve (P = 0.6) and type of valve dysfunction (P = 0.22 for aortic stenosis) was not found to be different between groups. CONCLUSIONS Irrespective of aortic valve morphology and function, ascending aortic blood flow patterns are linked to distinct patterns of ascending aortic aneurysm morphology. Implementation of quantitative local blood flow analyses might help to improve aneurysm risk stratification in the future.
Collapse
Affiliation(s)
- Fabian A Kari
- Department of Cardiovascular Surgery, Heart Center Freiburg University, Freiburg, Germany
| | - Nadja Kocher
- Department of Cardiovascular Surgery, Heart Center Freiburg University, Freiburg, Germany
| | - Friedhelm Beyersdorf
- Department of Cardiovascular Surgery, Heart Center Freiburg University, Freiburg, Germany
| | - Anke Tscheuschler
- Department of Cardiovascular Surgery, Heart Center Freiburg University, Freiburg, Germany
| | - Philipp Meffert
- Department of Cardiovascular Surgery, Heart Center Freiburg University, Freiburg, Germany
| | - Bartosz Rylski
- Department of Cardiovascular Surgery, Heart Center Freiburg University, Freiburg, Germany
| | - Matthias Siepe
- Department of Cardiovascular Surgery, Heart Center Freiburg University, Freiburg, Germany
| | - Maximilian F Russe
- Department of Diagnostic Radiology, University Medical Center Freiburg, Freiburg, Germany
| | - Michael D Hope
- Department of Diagnostic Radiology, University of San Francisco, San Francisco, CA, USA
| |
Collapse
|
37
|
Kontopodis N, Metaxa E, Papaharilaou Y, Tavlas E, Tsetis D, Ioannou C. Advancements in identifying biomechanical determinants for abdominal aortic aneurysm rupture. Vascular 2014; 23:65-77. [PMID: 24757027 DOI: 10.1177/1708538114532084] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Abdominal aortic aneurysms are a common health problem and currently the need for surgical intervention is determined based on maximum diameter and growth rate criteria. Since these universal variables often fail to predict accurately every abdominal aortic aneurysms evolution, there is a considerable effort in the literature for other markers to be identified towards individualized rupture risk estimations and growth rate predictions. To this effort, biomechanical tools have been extensively used since abdominal aortic aneurysm rupture is in fact a material failure of the diseased arterial wall to compensate the stress acting on it. The peak wall stress, the role of the unique geometry of every individual abdominal aortic aneurysm as well as the mechanical properties and the local strength of the degenerated aneurysmal wall, all confer to rupture risk. In this review article, the assessment of these variables through mechanical testing, advanced imaging and computational modeling is reviewed and the clinical perspective is discussed.
Collapse
Affiliation(s)
- Nikolaos Kontopodis
- Department of Vascular Surgery, University of Crete Medical School, Heraklion, Greece
| | - Eleni Metaxa
- Institute of Applied and Computational Mathematics, Foundation for Research and Technology-Hellas, Greece
| | - Yannis Papaharilaou
- Institute of Applied and Computational Mathematics, Foundation for Research and Technology-Hellas, Greece
| | - Emmanouil Tavlas
- Department of Vascular Surgery, University of Crete Medical School, Heraklion, Greece
| | - Dimitrios Tsetis
- Department of Interventional Radiology, University of Crete Medical School, Heraklion, Greece
| | - Christos Ioannou
- Department of Vascular Surgery, University of Crete Medical School, Heraklion, Greece
| |
Collapse
|
38
|
Robert N, Frank M, Avenin L, Hemery F, Becquemin JP. Influence of Atmospheric Pressure on Infrarenal Abdominal Aortic Aneurysm Rupture. Ann Vasc Surg 2014; 28:547-53. [DOI: 10.1016/j.avsg.2013.02.030] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2013] [Revised: 02/06/2013] [Accepted: 02/06/2013] [Indexed: 10/25/2022]
|
39
|
Biomarker für Scherstress und Wandspannung in thorakalen Aortenaneurysmen. ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE 2014. [DOI: 10.1007/s00398-013-1032-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
40
|
Finite element modeling of a novel self-expanding endovascular stent method in treatment of aortic aneurysms. Sci Rep 2014; 4:3630. [PMID: 24406869 PMCID: PMC3887389 DOI: 10.1038/srep03630] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2013] [Accepted: 12/12/2013] [Indexed: 01/07/2023] Open
Abstract
A novel large self-expanding endovascular stent was designed with strut thickness of 70 μm × 70 μm width. The method was developed and investigated to identify a novel simpler technique in aortic aneurysm therapy. Stage 1 analysis was performed after deploying it in a virtual aneurysm model of 6 cm wide × 6 cm long fusiform hyper-elastic anisotropic design. At cell width of 9 mm, there was no buckling or migration of the stent at 180 Hg. Radial force of the stents was estimated after parametric variations. In stage 2 analysis, a prototype 300 μm × 150 μm stent with a cell width of 9 mm was chosen, and it was evaluated similarly after embedding in the aortic wall, and also with a tissue overgrowth of 1 mm over the stent. The 300/150 μm stent reduced the peak wall stress by 70% in the aneurysm and 50% reduction in compliance after embedding. Stage 3 analysis was performed to study the efficacy of stents with struts (thickness/width) 70/70, 180/100 and 300/150 μm after embedding and tissue overgrowth. The adjacent wall stresses were very minimal in stents with 180/100 and 70/70 μm struts after embedding. There is potential for a novel stent method in aortic aneurysm therapy.
Collapse
|
41
|
Martufi G, Christian Gasser T. Review: the role of biomechanical modeling in the rupture risk assessment for abdominal aortic aneurysms. J Biomech Eng 2013; 135:021010. [PMID: 23445055 DOI: 10.1115/1.4023254] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
AAA disease is a serious condition and a multidisciplinary approach including biomechanics is needed to better understand and more effectively treat this disease. A rupture risk assessment is central to the management of AAA patients, and biomechanical simulation is a powerful tool to assist clinical decisions. Central to such a simulation approach is a need for robust and physiologically relevant models. Vascular tissue senses and responds actively to changes in its mechanical environment, a crucial tissue property that might also improve the biomechanical AAA rupture risk assessment. Specifically, constitutive modeling should not only focus on the (passive) interaction of structural components within the vascular wall, but also how cells dynamically maintain such a structure. In this article, after specifying the objectives of an AAA rupture risk assessment, the histology and mechanical properties of AAA tissue, with emphasis on the wall, are reviewed. Then a histomechanical constitutive description of the AAA wall is introduced that specifically accounts for collagen turnover. A test case simulation clearly emphasizes the need for constitutive descriptions that remodels with respect to the mechanical loading state. Finally, remarks regarding modeling of realistic clinical problems and possible future trends conclude the article.
Collapse
Affiliation(s)
- Giampaolo Martufi
- Department of Solid Mechanics, School of Engineering Sciences, Royal Institute of Technology (KTH), Osquars Backe 1, SE-100 44 Stockholm, Sweden.
| | | |
Collapse
|
42
|
Bashur CA, Rao RR, Ramamurthi A. Perspectives on stem cell-based elastic matrix regenerative therapies for abdominal aortic aneurysms. Stem Cells Transl Med 2013; 2:401-8. [PMID: 23677642 DOI: 10.5966/sctm.2012-0185] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023] Open
Abstract
Abdominal aortic aneurysms (AAAs) are potentially fatal conditions that are characterized by decreased flexibility of the aortic wall due to proteolytic loss of the structural matrix. This leads to their gradual weakening and ultimate rupture. Drug-based inhibition of proteolytic enzymes may provide a nonsurgical treatment alternative for growing AAAs, although it might at best be sufficient to slow their growth. Regenerative repair of disrupted elastic matrix is required if regression of AAAs to a healthy state is to be achieved. Terminally differentiated adult and diseased vascular cells are poorly capable of affecting such regenerative repair. In this context, stem cells and their smooth muscle cell-like derivatives may represent alternate cell sources for regenerative AAA cell therapies. This article examines the pros and cons of using different autologous stem cell sources for AAA therapy, the requirements they must fulfill to provide therapeutic benefit, and the current progress toward characterizing the cells' ability to synthesize elastin, assemble elastic matrix structures, and influence the regenerative potential of diseased vascular cell types. The article also provides a detailed perspective on the limitations, uncertainties, and challenges that will need to be overcome or circumvented to translate current strategies for stem cell use into clinically viable AAA therapies. These therapies will provide a much needed nonsurgical treatment option for the rapidly growing, high-risk, and vulnerable elderly demographic.
Collapse
MESH Headings
- Aged
- Animals
- Aorta, Abdominal/drug effects
- Aorta, Abdominal/metabolism
- Aorta, Abdominal/pathology
- Aortic Aneurysm, Abdominal/metabolism
- Aortic Aneurysm, Abdominal/pathology
- Aortic Aneurysm, Abdominal/rehabilitation
- Aortic Aneurysm, Abdominal/therapy
- Becaplermin
- Elasticity/drug effects
- Elasticity/physiology
- Elastin/biosynthesis
- Extracellular Matrix/drug effects
- Extracellular Matrix/metabolism
- Humans
- Myocytes, Smooth Muscle/cytology
- Myocytes, Smooth Muscle/metabolism
- Proto-Oncogene Proteins c-sis/pharmacology
- Regeneration/drug effects
- Regeneration/physiology
- Stem Cell Transplantation/methods
- Stem Cell Transplantation/trends
- Stem Cells/cytology
- Stem Cells/metabolism
- Transforming Growth Factor beta/pharmacology
- Transplantation, Autologous
Collapse
Affiliation(s)
- Chris A Bashur
- Department of Biomedical Engineering, Cleveland Clinic, Cleveland, OH, USA
| | | | | |
Collapse
|
43
|
Abstract
Decreased smoking has likely had the most significant impact on reducing the prevalence of AAAs. In a review of public data in England and Wales, Anjum and colleagues illustrated a reduction of AAA rupture from 1997 to2009 across all ages attributed to a concurrent decrease in prevalence of smoking. This trend has also been noted in a meta-analysis from Sweeting and colleagues and attributed to a reduction in the prevalence of smoking since the mid-1970s along with an enhanced awareness of cardiovascular risk factor reduction and selective aneurysm screening. Along with an effort to reduce AAA progression and rupture, tools to predict patient-specific risk of AAA rupture are evolving with refined models that incorporate both aneurysm wall stress and wall strength likely to provide the most promising approach. Although the role of statins, ACE inhibitors, beta-blockers, and aspirin in preventing or slowing aneurysmal rupture remains unresolved, their proven benefit in reducing long-term cardiovascular mortality suggests that these medications should be considered in any patient with a small AAA. Currently, randomized trials do not show any survival benefit for open or endovascular repair for small aneurysms in the range of 4.0 to 5.4 cm. AAA repair, whether through an endovascular or open approach, is not without potential complication. Even at centers of excellence, the 30-day mortality rate for conventional AAA surgery is 3% to 5%, with rates of major morbidityranging from 15% to 40%. The Society for Vascular Surgery guidelines recommends surveillance for patients with a fusiform AAA of 4.0 to 5.4 cm. The risk of AAA rupture appears to be decreasing through heightened public awareness, advanced technology for AAA detection, screening and surveillance, improved understanding of biomechanics and natural progression in AAA rupture, along with the availability of a wide range of medical therapies for risk factor reduction and minimally invasive options for AAA repair.
Collapse
Affiliation(s)
- Andy M Lee
- Department of Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, 110 Francis Street, Suite 9B, Boston, MA 02215, USA
| | | |
Collapse
|
44
|
Kelly S, O'Rourke M. Fluid, solid and fluid-structure interaction simulations on patient-based abdominal aortic aneurysm models. Proc Inst Mech Eng H 2012; 226:288-304. [PMID: 22611869 DOI: 10.1177/0954411911435592] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
This article describes the use of fluid, solid and fluid-structure interaction simulations on three patient-based abdominal aortic aneurysm geometries. All simulations were carried out using OpenFOAM, which uses the finite volume method to solve both fluid and solid equations. Initially a fluid-only simulation was carried out on a single patient-based geometry and results from this simulation were compared with experimental results. There was good qualitative and quantitative agreement between the experimental and numerical results, suggesting that OpenFOAM is capable of predicting the main features of unsteady flow through a complex patient-based abdominal aortic aneurysm geometry. The intraluminal thrombus and arterial wall were then included, and solid stress and fluid-structure interaction simulations were performed on this, and two other patient-based abdominal aortic aneurysm geometries. It was found that the solid stress simulations resulted in an under-estimation of the maximum stress by up to 5.9% when compared with the fluid-structure interaction simulations. In the fluid-structure interaction simulations, flow induced pressure within the aneurysm was found to be up to 4.8% higher than the value of peak systolic pressure imposed in the solid stress simulations, which is likely to be the cause of the variation in the stress results. In comparing the results from the initial fluid-only simulation with results from the fluid-structure interaction simulation on the same patient, it was found that wall shear stress values varied by up to 35% between the two simulation methods. It was concluded that solid stress simulations are adequate to predict the maximum stress in an aneurysm wall, while fluid-structure interaction simulations should be performed if accurate prediction of the fluid wall shear stress is necessary. Therefore, the decision to perform fluid-structure interaction simulations should be based on the particular variables of interest in a given study.
Collapse
Affiliation(s)
- Sinead Kelly
- School of Mechanical and Materials Engineering, University College Dublin, Belfield, Ireland
| | | |
Collapse
|
45
|
Konofagou E, Lee WN, Luo J, Provost J, Vappou J. Physiologic cardiovascular strain and intrinsic wave imaging. Annu Rev Biomed Eng 2012; 13:477-505. [PMID: 21756144 DOI: 10.1146/annurev-bioeng-071910-124721] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Cardiovascular disease remains the primary killer worldwide. The heart, essentially an electrically driven mechanical pump, alters its mechanical and electrical properties to compensate for loss of normal mechanical and electrical function. The same adjustment also is performed in the vessels, which constantly adapt their properties to accommodate mechanical and geometrical changes related to aging or disease. Real-time, quantitative assessment of cardiac contractility, conduction, and vascular function before the specialist can visually detect it could be feasible. This new physiologic data could open up interactive therapy regimens that are currently not considered. The eventual goal of this technology is to provide a specific method for estimating the position and severity of contraction defects in cardiac infarcts or angina. This would improve care and outcomes as well as detect stiffness changes and overcome the current global measurement limitations in the progression of vascular disease, at little more cost or risk than that of a clinical ultrasound.
Collapse
Affiliation(s)
- Elisa Konofagou
- Ultrasound and Elasticity Imaging Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY 10023, USA.
| | | | | | | | | |
Collapse
|
46
|
Mechanical behaviour and rupture of normal and pathological human ascending aortic wall. Med Biol Eng Comput 2012; 50:559-66. [PMID: 22391945 DOI: 10.1007/s11517-012-0876-x] [Citation(s) in RCA: 88] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2011] [Accepted: 02/12/2012] [Indexed: 01/15/2023]
Abstract
The mechanical properties of aortic wall, both healthy and pathological, are needed in order to develop and improve diagnostic and interventional criteria, and for the development of mechanical models to assess arterial integrity. This study focuses on the mechanical behaviour and rupture conditions of the human ascending aorta and its relationship with age and pathologies. Fresh ascending aortic specimens harvested from 23 healthy donors, 12 patients with bicuspid aortic valve (BAV) and 14 with aneurysm were tensile-tested in vitro under physiological conditions. Tensile strength, stretch at failure and elbow stress were measured. The obtained results showed that age causes a major reduction in the mechanical parameters of healthy ascending aortic tissue, and that no significant differences are found between the mechanical strength of aneurysmal or BAV aortic specimens and the corresponding age-matched control group. The physiological level of the stress in the circumferential direction was also computed to assess the physiological operation range of healthy and diseased ascending aortas. The mean physiological wall stress acting on pathologic aortas was found to be far from rupture, with factors of safety (defined as the ratio of tensile strength to the mean wall stress) larger than six. In contrast, the physiological operation of pathologic vessels lays in the stiff part of the response curve, losing part of its function of damping the pressure waves from the heart.
Collapse
|
47
|
Zhao S, Li W, Gu L. Biomechanical prediction of abdominal aortic aneurysm rupture risk: Sensitivity analysis. ACTA ACUST UNITED AC 2012. [DOI: 10.4236/jbise.2012.511083] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
48
|
Di Achille P, Celi S, Di Puccio F, Forte P. Anisotropic AAA: Computational comparison between four and two fiber family material models. J Biomech 2011; 44:2418-26. [DOI: 10.1016/j.jbiomech.2011.06.029] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2011] [Revised: 06/21/2011] [Accepted: 06/26/2011] [Indexed: 11/25/2022]
|
49
|
Moll FL, Powell JT, Fraedrich G, Verzini F, Haulon S, Waltham M, van Herwaarden JA, Holt PJE, van Keulen JW, Rantner B, Schlösser FJV, Setacci F, Ricco JB. Management of abdominal aortic aneurysms clinical practice guidelines of the European society for vascular surgery. Eur J Vasc Endovasc Surg 2011; 41 Suppl 1:S1-S58. [PMID: 21215940 DOI: 10.1016/j.ejvs.2010.09.011] [Citation(s) in RCA: 1033] [Impact Index Per Article: 73.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2010] [Accepted: 09/12/2010] [Indexed: 12/11/2022]
Affiliation(s)
- F L Moll
- Department of Vascular Surgery, University Medical Center Utrecht, The Netherlands.
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
50
|
Biomechanics and Pathobiology of Aortic Aneurysms. STUDIES IN MECHANOBIOLOGY, TISSUE ENGINEERING AND BIOMATERIALS 2011. [DOI: 10.1007/8415_2011_84] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|