1
|
Rivera E, Navarrete A, Garcia-Herrera CM, Gordillo L, Cerda E, Celentano DJ, Gonzalez-Candia A, Herrera EA. Biomechanical and histomorphometric characterization of the melatonin treatment effect in the carotid artery subjected to hypobaric hypoxia. Front Bioeng Biotechnol 2025; 13:1554004. [PMID: 40309506 PMCID: PMC12041024 DOI: 10.3389/fbioe.2025.1554004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2024] [Accepted: 04/02/2025] [Indexed: 05/02/2025] Open
Abstract
This study aims to assess the efficacy of melatonin in mitigating the adverse effects of hypobaric hypoxia on the cardiovascular system of neonatal lambs (30 days old). Two groups were considered for this purpose: (i) Melatonin-treated group (N = 5) and (ii) Control group (N = 6) without treatment. All subjects were exposed to hypobaric hypoxia during gestation and perinatal periods, with melatonin administered after birth. The study focused on the carotid artery, a known predictor of cardiovascular risk. Biomechanical tests, morphometric, and histological measurements were conducted, and a numerical model was developed based on the biomechanical data. Key findings showed remodeling effects: Firstly, a realignment of collagen fibers towards a longitudinal direction was observed with melatonin treatment, similar to non-hypoxic arteries. Second, changes in residual stress and ex-vivo luminal radius were noted, aiming to reduce wall stress and increase vascular resistance. These changes indicate an antihypertensive response, reducing the effects of increased blood pressure and flow due to hypobaric hypoxia. This study demonstrates that biomechanical and histomorphometric methodologies effectively assess the beneficial effects of melatonin treatment under hypobaric hypoxia exposure.
Collapse
Affiliation(s)
- Eugenio Rivera
- Departamento de Ingeniería Mecánica, Universidad de Santiago de Chile, Santiago, Chile
| | - Alvaro Navarrete
- Departamento de Ingeniería Mecánica, Universidad de Santiago de Chile, Santiago, Chile
| | | | - Leonardo Gordillo
- Departamento de Física, Universidad de Santiago de Chile, Santiago, Chile
| | - Enrique Cerda
- Departamento de Física, Universidad de Santiago de Chile, Santiago, Chile
| | - Diego J. Celentano
- Department of Mechanical and Metallurgical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile
| | | | - Emilio A. Herrera
- Pathophysiology Program, Faculty of Medicine, Institute of Biomedical Sciences (ICBM), Universidad de Chile, Santiago, Chile
- International Center for Andean Studies (INCAS), Universidad de Chile, Santiago, Chile
| |
Collapse
|
2
|
Latorre Molins ÁT, Guala A, Dux-Santoy L, Teixidó-Turà G, Rodríguez-Palomares JF, Martínez Barca MÁ, Peña Baquedano E. Estimating nonlinear anisotropic properties of healthy and aneurysm ascending aortas using magnetic resonance imaging. Biomech Model Mechanobiol 2025; 24:233-250. [PMID: 39586942 PMCID: PMC11846743 DOI: 10.1007/s10237-024-01907-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2024] [Accepted: 10/27/2024] [Indexed: 11/27/2024]
Abstract
An ascending aortic aneurysm is an often asymptomatic localized dilatation of the aorta. Aortic rupture is a life-threatening event that occurs when the stress on the aortic wall exceeds its mechanical strength. Therefore, patient-specific finite element models could play an important role in estimating the risk of rupture. This requires not only the geometry of the aorta but also the nonlinear anisotropic properties of the tissue. In this study, we presented a methodology to estimate the mechanical properties of the aorta from magnetic resonance imaging (MRI). As a theoretical framework, we used finite element models to which we added noise to simulate clinical data from real patient geometry and different properties of healthy and aneurysmal aortic tissues collected from the literature. The proposed methodology considered the nonlinear properties, the zero pressure geometry, the heart motion, and the external tissue support. In addition, we analyzed the aorta as a homogeneous material and as a heterogeneous model with different properties for the ascending and descending parts. The methodology was also applied to pre-surgical,in vivo MRI data of a patient who underwent surgery during which an aortic wall sample was obtained. The results were compared with those obtained from ex vivo biaxial test of the patient's tissue sample. The methodology showed promising results after successfully recovering the nonlinear anisotropic material properties of all analyzed cases. This study demonstrates that the variable used during the optimization process can affect the result. In particular, variables such as principal strains were found to obtain more realistic materials than the displacement field.
Collapse
Affiliation(s)
| | - Andrea Guala
- Vall d'Hebron Institut de Recerca, Barcelona, Spain
- Biomedical Research Networking Center on Cardiovascular Diseases (CIBER-CV), Instituto de Salud Carlos III, Madrid, Spain
| | | | - Gisela Teixidó-Turà
- Vall d'Hebron Institut de Recerca, Barcelona, Spain
- Biomedical Research Networking Center on Cardiovascular Diseases (CIBER-CV), Instituto de Salud Carlos III, Madrid, Spain
- Department of Cardiology, Hospital Universitari Vall d'Hebron, Barcelona, Spain
| | - José Fernando Rodríguez-Palomares
- Vall d'Hebron Institut de Recerca, Barcelona, Spain
- Biomedical Research Networking Center on Cardiovascular Diseases (CIBER-CV), Instituto de Salud Carlos III, Madrid, Spain
- Department of Cardiology, Hospital Universitari Vall d'Hebron, Barcelona, Spain
- Departament de Medicina, Universitat Autónoma de Barcelona. Bellaterra, Barcelona, Spain
| | - Miguel Ángel Martínez Barca
- Aragón Institute for Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain
- Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Zaragoza, Spain
| | - Estefanía Peña Baquedano
- Aragón Institute for Engineering Research (I3A), University of Zaragoza, Zaragoza, Spain.
- Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN), Zaragoza, Spain.
| |
Collapse
|
3
|
Parikh S, Wehrens A, Giudici A, Ganizada B, Saraber P, Schurgers L, Debeij G, Natour E, Maessen J, Huberts W, Delhaas T, Reesink K, Bidar E. Interpretation of intra-operative strain differences in ascending thoracic aortic repair patients. J Biomech 2025; 179:112447. [PMID: 39644801 DOI: 10.1016/j.jbiomech.2024.112447] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Revised: 11/10/2024] [Accepted: 11/28/2024] [Indexed: 12/09/2024]
Abstract
Local biaxial deformation plays a pivotal role in evaluating the tissue state of the ascending aorta and in driving intramural cell-mediated tissue remodeling. Unfortunately, the absence of anatomical markers on the ascending aorta presents challenges in capturing deformation. Utilizing our established intra-operative biaxial strain measurement method, we delineated local biaxial deformation characteristics in patients undergoing aortic valve replacement and coronary artery bypass graft surgery recipients (n = 20), and Aortic Repair surgery patients (n = 47). Expectedly, mean circumferential strains positively correlated with pulse pressure and negatively correlated with age and diameter. A new observation was that the mean axial strains exhibited the same trend as the mean circumferential strains when correlated with pulse pressure, age and diameter. Interestingly, on analyzing local biaxial strains, our findings revealed higher circumferential strains (by 1 %) proximal to the heart compared to distal regions across the cohorts and within each patient cohort. Furthermore, no discernible regional strain distinctions were noted between the medial and lateral sides of the ascending aorta for the entire patient population and individual cohorts. Patients undergoing Aortic Repair surgery indicated lower strains (ranging from 1 to 3 %) as compared to the other cohort. Our approach holds the potential to establish a foundational framework for the integrated examination of the mechanical and biological conditions and their role in ascending aortic aneurysm development.
Collapse
Affiliation(s)
- Shaiv Parikh
- Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands.
| | - Anne Wehrens
- Department of Cardiothoracic Surgery, CARIM School for Cardiovascular Diseases, Heart & Vascular Centre, Maastricht University Medical Centre (MUMC+), Maastricht, The Netherlands.
| | - Alessandro Giudici
- Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands; GROW School for Oncology and Reproduction, Maastricht University, Maastricht, The Netherlands.
| | - Berta Ganizada
- Department of Cardiothoracic Surgery, CARIM School for Cardiovascular Diseases, Heart & Vascular Centre, Maastricht University Medical Centre (MUMC+), Maastricht, The Netherlands; Department of Biochemistry, CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands.
| | - Pepijn Saraber
- Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands; Department of Biochemistry, CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands.
| | - Leon Schurgers
- Department of Biochemistry, CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands.
| | - Gijs Debeij
- Department of Cardiothoracic Surgery, CARIM School for Cardiovascular Diseases, Heart & Vascular Centre, Maastricht University Medical Centre (MUMC+), Maastricht, The Netherlands.
| | - Ehsan Natour
- Department of Cardiothoracic Surgery, CARIM School for Cardiovascular Diseases, Heart & Vascular Centre, Maastricht University Medical Centre (MUMC+), Maastricht, The Netherlands.
| | - Jos Maessen
- Department of Cardiothoracic Surgery, CARIM School for Cardiovascular Diseases, Heart & Vascular Centre, Maastricht University Medical Centre (MUMC+), Maastricht, The Netherlands.
| | - Wouter Huberts
- Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands; Department of Biomedical Engineering, Cardiovascular Biomechanics, Eindhoven University of Technology, Eindhoven, The Netherlands.
| | - Tammo Delhaas
- Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands.
| | - Koen Reesink
- Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University, Maastricht, The Netherlands.
| | - Elham Bidar
- Department of Cardiothoracic Surgery, CARIM School for Cardiovascular Diseases, Heart & Vascular Centre, Maastricht University Medical Centre (MUMC+), Maastricht, The Netherlands.
| |
Collapse
|
4
|
Perinajová R, van de Ven T, Roelse E, Xu F, Juffermans J, Westenberg J, Lamb H, Kenjereš S. A comprehensive MRI-based computational model of blood flow in compliant aorta using radial basis function interpolation. Biomed Eng Online 2024; 23:69. [PMID: 39039565 PMCID: PMC11265469 DOI: 10.1186/s12938-024-01251-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Accepted: 06/03/2024] [Indexed: 07/24/2024] Open
Abstract
BACKGROUND Properly understanding the origin and progression of the thoracic aortic aneurysm (TAA) can help prevent its growth and rupture. For a better understanding of this pathogenesis, the aortic blood flow has to be studied and interpreted in great detail. We can obtain detailed aortic blood flow information using magnetic resonance imaging (MRI) based computational fluid dynamics (CFD) with a prescribed motion of the aortic wall. METHODS We performed two different types of simulations-static (rigid wall) and dynamic (moving wall) for healthy control and a patient with a TAA. For the latter, we have developed a novel morphing approach based on the radial basis function (RBF) interpolation of the segmented 4D-flow MRI geometries at different time instants. Additionally, we have applied reconstructed 4D-flow MRI velocity profiles at the inlet with an automatic registration protocol. RESULTS The simulated RBF-based movement of the aorta matched well with the original 4D-flow MRI geometries. The wall movement was most dominant in the ascending aorta, accompanied by the highest variation of the blood flow patterns. The resulting data indicated significant differences between the dynamic and static simulations, with a relative difference for the patient of 7.47±14.18% in time-averaged wall shear stress and 15.97±43.32% in the oscillatory shear index (for the whole domain). CONCLUSIONS In conclusion, the RBF-based morphing approach proved to be numerically accurate and computationally efficient in capturing complex kinematics of the aorta, as validated by 4D-flow MRI. We recommend this approach for future use in MRI-based CFD simulations in broad population studies. Performing these would bring a better understanding of the onset and growth of TAA.
Collapse
Affiliation(s)
- Romana Perinajová
- Department of Chemical Engineering, Faculty of Applied Sciences, Delft University of Technology, Delft, The Netherlands.
- J.M. Burgerscentrum Research School for Fluid Mechanics, Delft, The Netherlands.
| | - Thijn van de Ven
- Department of Chemical Engineering, Faculty of Applied Sciences, Delft University of Technology, Delft, The Netherlands
| | - Elise Roelse
- Department of Chemical Engineering, Faculty of Applied Sciences, Delft University of Technology, Delft, The Netherlands
| | - Fei Xu
- Department of Chemical Engineering, Faculty of Applied Sciences, Delft University of Technology, Delft, The Netherlands
- J.M. Burgerscentrum Research School for Fluid Mechanics, Delft, The Netherlands
| | - Joe Juffermans
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Jos Westenberg
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Hildo Lamb
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Saša Kenjereš
- Department of Chemical Engineering, Faculty of Applied Sciences, Delft University of Technology, Delft, The Netherlands.
- J.M. Burgerscentrum Research School for Fluid Mechanics, Delft, The Netherlands.
| |
Collapse
|
5
|
Goetz WA, Yao J, Brener M, Puri R, Swaans M, Schopka S, Wiesner S, Creutzenberg M, Sievert H, Kassab GS. Inversion of Left Ventricular Axial Shortening: In Silico Proof of Concept for Treatment of HFpEF. Bioengineering (Basel) 2024; 11:676. [PMID: 39061758 PMCID: PMC11274197 DOI: 10.3390/bioengineering11070676] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2024] [Revised: 06/24/2024] [Accepted: 06/28/2024] [Indexed: 07/28/2024] Open
Abstract
Left ventricular (LV) longitudinal function is mechanically coupled to the elasticity of the ascending aorta (AA). The pathophysiologic link between a stiff AA and reduced longitudinal strain and the subsequent deterioration in longitudinal LV systolic function is likely relevant in heart failure with preserved ejection fraction (HFpEF). The proposed therapeutic effect of freeing the LV apex and allowing for LV inverse longitudinal shortening was studied in silico utilizing the Living Left Heart Human Model (Dassault Systémes Simulia Corporation). LV function was evaluated in a model with (A) an elastic AA, (B) a stiff AA, and (C) a stiff AA with a free LV apex. The cardiac model simulation demonstrated that freeing the apex caused inverse LV longitudinal shortening that could abolish the deleterious mechanical effect of a stiff AA on LV function. A stiff AA and impairment of the LV longitudinal strain are common in patients with HFpEF. The hypothesis-generating model strongly suggests that freeing the apex and inverse longitudinal shortening may improve LV function in HFpEF patients with a stiff AA.
Collapse
Affiliation(s)
- Wolfgang A. Goetz
- Cardiothoracic Surgery, University Hospital Regensburg, 93053 Regensburg, Germany; (W.A.G.); (S.S.)
| | - Jiang Yao
- Dassault Systémes, Johnston, RI 02919, USA;
| | - Michael Brener
- Division of Cardiology, Columbia University Irving Medical Center, New York, NY 10027, USA
| | - Rishi Puri
- Cleveland Clinic, Cleveland, OH 44195, USA
| | - Martin Swaans
- St. Antonius Ziekenhuis, 3435 Nieuwegein, The Netherlands
| | - Simon Schopka
- Cardiothoracic Surgery, University Hospital Regensburg, 93053 Regensburg, Germany; (W.A.G.); (S.S.)
| | - Sigrid Wiesner
- Cardiothoracic Surgery, University Hospital Regensburg, 93053 Regensburg, Germany; (W.A.G.); (S.S.)
| | - Marcus Creutzenberg
- Cardiothoracic Surgery, University Hospital Regensburg, 93053 Regensburg, Germany; (W.A.G.); (S.S.)
| | | | | |
Collapse
|
6
|
Goetz WA, Yao J, Brener M, Puri R, Swaans M, Schopka S, Wiesner S, Creutzenberg M, Sievert H, Kassab GS. The Stiffness of the Ascending Aorta Has a Direct Impact on Left Ventricular Function: An In Silico Model. Bioengineering (Basel) 2024; 11:603. [PMID: 38927839 PMCID: PMC11200724 DOI: 10.3390/bioengineering11060603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2024] [Revised: 06/04/2024] [Accepted: 06/10/2024] [Indexed: 06/28/2024] Open
Abstract
During systole, longitudinal shortening of the left ventricle (LV) displaces the aortic root toward the apex of the heart and stretches the ascending aorta (AA). An in silico study (Living Left Heart Human Model, Dassault Systèmes Simulia Corporation) demonstrated that stiffening of the AA affects myocardial stress and LV strain patterns. With AA stiffening, myofiber stress increased overall in the LV, with particularly high-stress areas at the septum. The most pronounced reduction in strain was noted along the septal longitudinal region. The pressure-volume loops showed that AA stiffening caused a deterioration in LV function, with increased end-systolic volume, reduced systolic LV pressure, decreased stroke volume and effective stroke work, but elevated end-diastolic pressure. An increase in myofiber contractility indicated that stroke volume and effective stroke work could be recovered, with an increase in LV end-systolic pressure and a decrease in end-diastolic pressure. Longitudinal and radial strains remained reduced, but circumferential strains increased over baseline, compensating for lost longitudinal LV function. Myofiber stress increased overall, with the most dramatic increase in the septal region and the LV apex. We demonstrate a direct mechanical pathophysiologic link between stiff AA and reduced longitudinal left ventricular strain which are common in patients with HFpEF.
Collapse
Affiliation(s)
- Wolfgang Anton Goetz
- Cardiothoracic Surgery, University Hospital Regensburg, 93053 Regensburg, Germany; (W.A.G.); (M.C.)
| | - Jiang Yao
- Dassault Systèmes, Johnston, RI 02919, USA
| | - Michael Brener
- Division of Cardiology, Columbia University Irving Medical Center, New York, NY 10027, USA;
| | - Rishi Puri
- Cleveland Clinic, Cleveland, OH 44195, USA
| | - Martin Swaans
- St. Antonius Ziekenhuis, 3435 Nieuwegein, The Netherlands;
| | - Simon Schopka
- Cardiothoracic Surgery, University Hospital Regensburg, 93053 Regensburg, Germany; (W.A.G.); (M.C.)
| | - Sigrid Wiesner
- Cardiothoracic Surgery, University Hospital Regensburg, 93053 Regensburg, Germany; (W.A.G.); (M.C.)
| | - Marcus Creutzenberg
- Cardiothoracic Surgery, University Hospital Regensburg, 93053 Regensburg, Germany; (W.A.G.); (M.C.)
| | | | | |
Collapse
|
7
|
Ding CCA, Dokos S, Bakir AA, Zamberi NJ, Liew YM, Chan BT, Md Sari NA, Avolio A, Lim E. Simulating impaired left ventricular-arterial coupling in aging and disease: a systematic review. Biomed Eng Online 2024; 23:24. [PMID: 38388416 PMCID: PMC10885508 DOI: 10.1186/s12938-024-01206-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Accepted: 01/11/2024] [Indexed: 02/24/2024] Open
Abstract
Aortic stenosis, hypertension, and left ventricular hypertrophy often coexist in the elderly, causing a detrimental mismatch in coupling between the heart and vasculature known as ventricular-vascular (VA) coupling. Impaired left VA coupling, a critical aspect of cardiovascular dysfunction in aging and disease, poses significant challenges for optimal cardiovascular performance. This systematic review aims to assess the impact of simulating and studying this coupling through computational models. By conducting a comprehensive analysis of 34 relevant articles obtained from esteemed databases such as Web of Science, Scopus, and PubMed until July 14, 2022, we explore various modeling techniques and simulation approaches employed to unravel the complex mechanisms underlying this impairment. Our review highlights the essential role of computational models in providing detailed insights beyond clinical observations, enabling a deeper understanding of the cardiovascular system. By elucidating the existing models of the heart (3D, 2D, and 0D), cardiac valves, and blood vessels (3D, 1D, and 0D), as well as discussing mechanical boundary conditions, model parameterization and validation, coupling approaches, computer resources and diverse applications, we establish a comprehensive overview of the field. The descriptions as well as the pros and cons on the choices of different dimensionality in heart, valve, and circulation are provided. Crucially, we emphasize the significance of evaluating heart-vessel interaction in pathological conditions and propose future research directions, such as the development of fully coupled personalized multidimensional models, integration of deep learning techniques, and comprehensive assessment of confounding effects on biomarkers.
Collapse
Affiliation(s)
- Corina Cheng Ai Ding
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, 50603, Kuala Lumpur, Malaysia
- Graduate School of Biomedical Engineering, Faculty of Engineering, University of New South Wales, Sydney, NSW, 2052, Australia
| | - Socrates Dokos
- Graduate School of Biomedical Engineering, Faculty of Engineering, University of New South Wales, Sydney, NSW, 2052, Australia
| | - Azam Ahmad Bakir
- University of Southampton Malaysia Campus, 79200, Iskandar Puteri, Johor, Malaysia
| | - Nurul Jannah Zamberi
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, 50603, Kuala Lumpur, Malaysia
- Graduate School of Biomedical Engineering, Faculty of Engineering, University of New South Wales, Sydney, NSW, 2052, Australia
| | - Yih Miin Liew
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, 50603, Kuala Lumpur, Malaysia
| | - Bee Ting Chan
- Department of Mechanical, Materials and Manufacturing Engineering, Faculty of Science and Engineering, University of Nottingham Malaysia, 43500, Selangor, Malaysia
| | - Nor Ashikin Md Sari
- Department of Medicine, Faculty of Medicine, University of Malaya, 50603, Kuala Lumpur, Malaysia
| | - Alberto Avolio
- Macquarie Medical School, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney, NSW, 2109, Australia
| | - Einly Lim
- Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, 50603, Kuala Lumpur, Malaysia.
| |
Collapse
|
8
|
Aghilinejad A, Rogers B, Geng H, Pahlevan NM. On the Longitudinal Wave Pumping in Fluid-filled Compliant Tubes. PHYSICS OF FLUIDS (WOODBURY, N.Y. : 1994) 2023; 35:091903. [PMID: 39640063 PMCID: PMC11618682 DOI: 10.1063/5.0165150] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/07/2024]
Abstract
This study investigates the physics of the longitudinal stretching-based wave pumping mechanism, a novel extension of the traditional impedance pump. In its simplest form, an impedance pump consists of a fluid-filled elastic tube connected to rigid tubes with a wave generator. These valveless pumps operate based on the principles of wave propagation in a fluid-filled compliant tube. Cardiovascular magnetic resonance imaging of the human circulatory system has shown substantial stretching of the aorta (the largest compliant artery of the body carrying blood) during the heart contraction and recoil of the aorta during the relaxation. Inspired by this dynamic mechanism, a comprehensive analysis of a longitudinal impedance pump is conducted in this study where waves are generated by stretching of the elastic wall and its recoil. We developed a fully coupled fluid-structure interaction computational model consisting of a straight fluid-filled elastic tube with longitudinal stretch at one end and fixed reflection site at the other end. The pump's behavior is quantified as a function of stretching frequency and tube wall characteristics. Our results indicate that stretch-related wave propagation and reflection can induce frequency-dependent pumping. Findings suggest a non-linear pattern for the mean flow-frequency relationship. Based on the analysis of the propagated waveforms, the underlying physical mechanism in the longitudinal impedance pump is discussed. It is shown that both the direction and magnitude of the net flow strongly depend on the wave characteristics. These findings provide a fundamental understanding of stretch-related wave pumping and can inform the future design of such pumps.
Collapse
Affiliation(s)
- Arian Aghilinejad
- Department of Aerospace and Mechanical Engineering, University of Southern California, 1002 Childs Way, Los Angeles, CA 90089, USA
| | - Bryson Rogers
- Department of Aerospace and Mechanical Engineering, University of Southern California, 1002 Childs Way, Los Angeles, CA 90089, USA
| | - Haojie Geng
- Department of Aerospace and Mechanical Engineering, University of Southern California, 1002 Childs Way, Los Angeles, CA 90089, USA
| | - Niema M Pahlevan
- Department of Aerospace and Mechanical Engineering, University of Southern California, 1002 Childs Way, Los Angeles, CA 90089, USA
- Division of Cardiovascular Medicine, Keck School of Medicine, University of Southern California, 1002 Childs Way, Los Angeles, CA 90089, USA
| |
Collapse
|
9
|
Rovas G, Bikia V, Stergiopulos N. Design and computational optimization of compliance-matching aortic grafts. Front Bioeng Biotechnol 2023; 11:1179174. [PMID: 37456727 PMCID: PMC10341153 DOI: 10.3389/fbioe.2023.1179174] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Accepted: 06/19/2023] [Indexed: 07/18/2023] Open
Abstract
Introduction: Synthetic vascular grafts have been widely used in clinical practice for aortic replacement surgery. Despite their high rates of surgical success, they remain significantly less compliant than the native aorta, resulting in a phenomenon called compliance mismatch. This incompatibility of elastic properties may cause serious post-operative complications, including hypertension and myocardial hypertrophy. Methods: To mitigate the risk for these complications, we designed a multi-layer compliance-matching stent-graft, that we optimized computationally using finite element analysis, and subsequently evaluated in vitro. Results: We found that our compliance-matching grafts attained the distensibility of healthy human aortas, including those of young adults, thereby significantly exceeding the distensibility of gold-standard grafts. The compliant grafts maintained their properties in a wide range of conditions that are expected after the implantation. Furthermore, the computational model predicted the graft radius with enough accuracy to allow computational optimization to be performed effectively. Conclusion: Compliance-matching grafts may offer a valuable improvement over existing prostheses and they could potentially mitigate the risk for post-operative complications attributed to excessive graft stiffness.
Collapse
|
10
|
Stokes C, Bonfanti M, Li Z, Xiong J, Chen D, Balabani S, Díaz-Zuccarini V. A novel MRI-based data fusion methodology for efficient, personalised, compliant simulations of aortic haemodynamics. J Biomech 2021; 129:110793. [PMID: 34715606 PMCID: PMC8907869 DOI: 10.1016/j.jbiomech.2021.110793] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Revised: 08/24/2021] [Accepted: 09/30/2021] [Indexed: 01/24/2023]
Abstract
We present a novel, cost-efficient methodology to simulate aortic haemodynamics in a patient-specific, compliant aorta using an MRI data fusion process. Based on a previously-developed Moving Boundary Method, this technique circumvents the high computational cost and numerous structural modelling assumptions required by traditional Fluid-Structure Interaction techniques. Without the need for Computed Tomography (CT) data, the MRI images required to construct the simulation can be obtained during a single imaging session. Black Blood MR Angiography and 2D Cine-MRI data were used to reconstruct the luminal geometry and calibrate wall movement specifically to each region of the aorta. 4D-Flow MRI and non-invasive pressure measurements informed patient-specific inlet and outlet boundary conditions. Luminal area closely matched 2D Cine-MRI measurements with a mean error of less than 4.6% across the cardiac cycle, while physiological pressure and flow distributions were simulated to within 3.3% of patient-specific targets. Moderate agreement with 4D-Flow MRI velocity data was observed. Despite lower peak velocity, an equivalent rigid-wall simulation predicted a mean Time-Averaged Wall Shear Stress (TAWSS) 13% higher than the compliant simulation. The agreement observed between compliant simulation results and MRI data is testament to the accuracy and efficiency of this MRI-based simulation technique.
Collapse
Affiliation(s)
- Catriona Stokes
- Mechanical Engineering Department, Roberts Engineering Building, University College London, Torrington Place, London, WC1E 7JE, United Kingdom; Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), Charles Bell House, London, W1W 7TY, United Kingdom.
| | - Mirko Bonfanti
- Mechanical Engineering Department, Roberts Engineering Building, University College London, Torrington Place, London, WC1E 7JE, United Kingdom; Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), Charles Bell House, London, W1W 7TY, United Kingdom.
| | - Zeyan Li
- School of Life Science, Beijing Institute of Technology, Beijing, China.
| | - Jiang Xiong
- Department of Vascular and Endovascular Surgery, Chinese PLA General Hospital, Beijing, China.
| | - Duanduan Chen
- School of Life Science, Beijing Institute of Technology, Beijing, China.
| | - Stavroula Balabani
- Mechanical Engineering Department, Roberts Engineering Building, University College London, Torrington Place, London, WC1E 7JE, United Kingdom; Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), Charles Bell House, London, W1W 7TY, United Kingdom.
| | - Vanessa Díaz-Zuccarini
- Mechanical Engineering Department, Roberts Engineering Building, University College London, Torrington Place, London, WC1E 7JE, United Kingdom; Wellcome/EPSRC Centre for Interventional and Surgical Sciences (WEISS), Charles Bell House, London, W1W 7TY, United Kingdom.
| |
Collapse
|
11
|
Ghadie NM, St-Pierre JP, Labrosse MR. The Contribution of Glycosaminoglycans/Proteoglycans to Aortic Mechanics in Health and Disease: A Critical Review. IEEE Trans Biomed Eng 2021; 68:3491-3500. [PMID: 33872141 DOI: 10.1109/tbme.2021.3074053] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
While elastin and collagen have received a lot of attention as major contributors to aortic biomechanics, glycosaminoglycans (GAGs) and proteoglycans (PGs) recently emerged as additional key players whose roles must be better elucidated if one hopes to predict aortic ruptures caused by aneurysms and dissections more reliably. GAGs are highly negatively charged polysaccharide molecules that exist in the extracellular matrix (ECM) of the arterial wall. In this critical review, we summarize the current understanding of the contributions of GAGs/PGs to the biomechanics of the normal aortic wall, as well as in the case of aortic diseases such as aneurysms and dissections. Specifically, we describe the fundamental swelling behavior of GAGs/PGs and discuss their contributions to residual stresses and aortic stiffness, thereby highlighting the importance of taking these polyanionic molecules into account in mathematical and numerical models of the aorta. We suggest specific lines of investigation to further the acquisition of experimental data to complement simulations and solidify our current understanding. We underscore different potential roles of GAGs/PGs in thoracic aortic aneurysm (TAAD) and abdominal aortic aneurysm (AAA). Namely, we report findings according to which the accumulation of GAGs/PGs in TAAD causes stress concentrations which may be sufficient to initiate and propagate delamination. On the other hand, there seems to be no clear indication of a relationship between the marked reduction in GAG/PG content and the stiffening and weakening of the aortic wall in AAA.
Collapse
|