1
|
Shin M, Martens PJ, Siegmund T, Kruzic JJ, Gludovatz B. A numerical study of dehydration induced fracture toughness degradation in human cortical bone. J Mech Behav Biomed Mater 2024; 153:106468. [PMID: 38493561 DOI: 10.1016/j.jmbbm.2024.106468] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2023] [Revised: 01/21/2024] [Accepted: 02/15/2024] [Indexed: 03/19/2024]
Abstract
A 2D plane strain extended finite element method (XFEM) model was developed to simulate three-point bending fracture toughness tests for human bone conducted in hydrated and dehydrated conditions. Bone microstructures and crack paths observed by micro-CT imaging were simulated using an XFEM damage model. Critical damage strains for the osteons, matrix, and cement lines were deduced for both hydrated and dehydrated conditions and it was found that dehydration decreases the critical damage strains by about 50%. Subsequent parametric studies using the various microstructural models were performed to understand the impact of individual critical damage strain variations on the fracture behavior. The study revealed the significant impact of the cement line critical damage strains on the crack paths and fracture toughness during the early stages of crack growth. Furthermore, a significant sensitivity of crack growth resistance and crack paths on critical strain values of the cement lines was found to exist for the hydrated environments where a small change in critical strain values of the cement lines can alter the crack path to give a significant reduction in fracture resistance. In contrast, in the dehydrated state where toughness is low, the sensitivity to changes in critical strain values of the cement lines is low. Overall, our XFEM model was able to provide new insights into how dehydration affects the micromechanisms of fracture in bone and this approach could be further extended to study the effects of aging, disease, and medical therapies on bone fracture.
Collapse
Affiliation(s)
- Mihee Shin
- School of Mechanical and Manufacturing Engineering, University of New South Wales (UNSW Sydney), Sydney, NSW, 2052, Australia
| | - Penny J Martens
- Graduate School of Biomedical Engineering, University of New South Wales (UNSW Sydney), Sydney, NSW, 2052, Australia
| | - Thomas Siegmund
- School of Mechanical Engineering, Purdue University, West Lafayette, IN, 47907, USA
| | - Jamie J Kruzic
- School of Mechanical and Manufacturing Engineering, University of New South Wales (UNSW Sydney), Sydney, NSW, 2052, Australia
| | - Bernd Gludovatz
- School of Mechanical and Manufacturing Engineering, University of New South Wales (UNSW Sydney), Sydney, NSW, 2052, Australia.
| |
Collapse
|
2
|
Liu Y, Tang C, Wen J, Guo H, Fan H. Mechanical characterization and water stability of loess improved by bio-based materials: An eco-friendly approach. Sci Total Environ 2024; 921:171111. [PMID: 38402965 DOI: 10.1016/j.scitotenv.2024.171111] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/24/2023] [Revised: 02/18/2024] [Accepted: 02/18/2024] [Indexed: 02/27/2024]
Abstract
Loess exhibits poor engineering properties, such as low strength and poor water stability. Conventional materials used for improving loess, such as cement and lime, result in environmental pollution issues throughout their production and application processes. To assess the efficacy of bio-based materials, including calcium alginate (CA), xanthan gum (XA), cotton fibers (CO) and flax fibers (FA) in the treatment of loess, the improved soil's strength, disintegration, and water resistance were examined. Subsequently, an optimal amendment approach was determined, and dry-wet cycle tests and microscopic observation were performed. The results show that 1.0 % calcium alginate can effectively enhance the strength of loess, significantly improving its resistance to disintegration with almost no observable disintegration; permeability is significantly reduced, and water repellency is enhanced. 2.0 % xanthan can improve the strength and disintegration resistance of loess, but the improvement in strength is lower than that of calcium alginate. Additionally, the improved soil with XA experiences a flocculent disintegration in static water, which cannot maintain the soil structure. Cotton fibers and flax fibers can enhance both compressive and tensile strength of the soil. The content of 0.45 % flax fibers is considered the optimal choice as it has no effect on water stability. Combining the above results, the combination of 1.0 % CA and 0.45 % FA has been selected to improve the loess, which effectively improves the comprehensive mechanical properties and water stability of the composite improved soil. The decrease in strength and mass loss rate are significantly reduced after dry-wet cycle tests. Microscopic tests show that calcium alginate connects soil particles by Ca2+ ionic bridges, which allows the cementing materials to fill the loess pores and exert the role of agglomeration and coagulation to enhance the integrity of the loess. This study shows that the bio-based material with calcium alginate as the main body can effectively improve the mechanical strength and water stability of the loess.
Collapse
Affiliation(s)
- Yifei Liu
- College of Water Resources and Architectural Engineering, Northwest A&F University, Yangling 712100, China; Problematic Rock and Soil Museum, Northwest A&F University, Yangling 712100, China; School of Transportation, Southeast University, Nanjing 211189, China
| | - Chaoxin Tang
- College of Water Resources and Architectural Engineering, Northwest A&F University, Yangling 712100, China; Problematic Rock and Soil Museum, Northwest A&F University, Yangling 712100, China; Powerchina Northwest Engineering Corporation Limited, Xi'an 710065, China
| | - Jixiang Wen
- College of Water Resources and Architectural Engineering, Northwest A&F University, Yangling 712100, China; Problematic Rock and Soil Museum, Northwest A&F University, Yangling 712100, China
| | - Hongdong Guo
- College of Water Resources and Architectural Engineering, Northwest A&F University, Yangling 712100, China; Problematic Rock and Soil Museum, Northwest A&F University, Yangling 712100, China
| | - Henghui Fan
- College of Water Resources and Architectural Engineering, Northwest A&F University, Yangling 712100, China; Problematic Rock and Soil Museum, Northwest A&F University, Yangling 712100, China.
| |
Collapse
|
3
|
Huang J, Hu X, Chen Z, Ouyang F, Li J, Hu Y, Zhao Y, Wang J, Yao F, Jing J, Cheng L. Fascin-1 limits myosin activity in microglia to control mechanical characterization of the injured spinal cord. J Neuroinflammation 2024; 21:88. [PMID: 38600569 PMCID: PMC11005239 DOI: 10.1186/s12974-024-03089-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Accepted: 04/02/2024] [Indexed: 04/12/2024] Open
Abstract
BACKGROUND Mechanical softening of the glial scar region regulates axonal regeneration to impede neurological recovery in central nervous system (CNS) injury. Microglia, a crucial cellular component of the glial scar, facilitate neuronal survival and neurological recovery after spinal cord injury (SCI). However, the critical mechanical characterization of injured spinal cord that harmonizes neuroprotective function of microglia remains poorly understood. METHODS Spinal cord tissue stiffness was assessed using atomic force microscopy (AFM) in a mouse model of crush injury. Pharmacological depletion of microglia using PLX5622 was used to explore the effect of microglia on mechanical characterization. Conditional knockout of Fascin-1 in microglia (Fascin-1 CKO) alone or in combination with inhibition of myosin activity was performed to delve into relevant mechanisms of microglia regulating mechanical signal. Immunofluorescence staining was performed to evaluate the related protein levels, inflammatory cells, and neuron survival after SCI. The Basso mouse scale score was calculated to assess functional recovery. RESULTS Spinal cord tissue significantly softens after SCI. Microglia depletion or Fascin-1 knockout in microglia limits tissue softening and alters mechanical characterization, which leads to increased tissue pathology and impaired functional recovery. Mechanistically, Fascin-1 inhibits myosin activation to promote microglial migration and control mechanical characterization after SCI. CONCLUSIONS We reveal that Fascin-1 limits myosin activity to regulate mechanical characterization after SCI, and this mechanical signal should be considered in future approaches for the treatment of CNS diseases.
Collapse
Affiliation(s)
- Jinxin Huang
- Department of Orthopaedics, The Second Affiliated Hospital of Anhui Medical University, Hefei, 230601, China
- Institute of Orthopaedics, Research Center for Translational Medicine, The Second Affiliated Hospital of Anhui Medical University, Hefei, 230601, China
| | - Xuyang Hu
- Department of Orthopaedics, The Second Affiliated Hospital of Anhui Medical University, Hefei, 230601, China
- Institute of Orthopaedics, Research Center for Translational Medicine, The Second Affiliated Hospital of Anhui Medical University, Hefei, 230601, China
| | - Zeqiang Chen
- Department of Orthopaedics, The Second Affiliated Hospital of Anhui Medical University, Hefei, 230601, China
- Institute of Orthopaedics, Research Center for Translational Medicine, The Second Affiliated Hospital of Anhui Medical University, Hefei, 230601, China
| | - Fangru Ouyang
- Department of Orthopaedics, The Second Affiliated Hospital of Anhui Medical University, Hefei, 230601, China
- Institute of Orthopaedics, Research Center for Translational Medicine, The Second Affiliated Hospital of Anhui Medical University, Hefei, 230601, China
| | - Jianjian Li
- Department of Orthopaedics, The Second Affiliated Hospital of Anhui Medical University, Hefei, 230601, China
- Institute of Orthopaedics, Research Center for Translational Medicine, The Second Affiliated Hospital of Anhui Medical University, Hefei, 230601, China
| | - Yixue Hu
- Department of Orthopaedics, The Second Affiliated Hospital of Anhui Medical University, Hefei, 230601, China
- Institute of Orthopaedics, Research Center for Translational Medicine, The Second Affiliated Hospital of Anhui Medical University, Hefei, 230601, China
| | - Yuanzhe Zhao
- Department of Orthopaedics, The Second Affiliated Hospital of Anhui Medical University, Hefei, 230601, China
- Institute of Orthopaedics, Research Center for Translational Medicine, The Second Affiliated Hospital of Anhui Medical University, Hefei, 230601, China
| | - Jingwen Wang
- Department of Orthopaedics, The Second Affiliated Hospital of Anhui Medical University, Hefei, 230601, China
- Institute of Orthopaedics, Research Center for Translational Medicine, The Second Affiliated Hospital of Anhui Medical University, Hefei, 230601, China
| | - Fei Yao
- Department of Orthopaedics, The Second Affiliated Hospital of Anhui Medical University, Hefei, 230601, China.
- Institute of Orthopaedics, Research Center for Translational Medicine, The Second Affiliated Hospital of Anhui Medical University, Hefei, 230601, China.
| | - Juehua Jing
- Department of Orthopaedics, The Second Affiliated Hospital of Anhui Medical University, Hefei, 230601, China.
- Institute of Orthopaedics, Research Center for Translational Medicine, The Second Affiliated Hospital of Anhui Medical University, Hefei, 230601, China.
| | - Li Cheng
- Department of Orthopaedics, The Second Affiliated Hospital of Anhui Medical University, Hefei, 230601, China.
- Institute of Orthopaedics, Research Center for Translational Medicine, The Second Affiliated Hospital of Anhui Medical University, Hefei, 230601, China.
| |
Collapse
|
4
|
Shin M, Kim DK, Jain M, Martens PJ, Turner RT, Iwaniec UT, Kruzic JJ, Gludovatz B. Impact of heavy alcohol consumption on cortical bone mechanical properties in male rhesus macaques. Bone 2024; 181:117041. [PMID: 38325648 DOI: 10.1016/j.bone.2024.117041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 01/31/2024] [Accepted: 02/02/2024] [Indexed: 02/09/2024]
Abstract
Chronic heavy alcohol consumption may influence the skeleton by suppressing intracortical bone remodeling which may impact the quality of bone and its mechanical properties. However, this aspect has not been thoroughly assessed in either humans or animal models whose cortical bone microstructure resembles the microstructure of human cortical bone. The current study is the first to investigate the effects of chronic heavy alcohol consumption on various mechanical properties of bone in a non-human primate model with intracortical remodeling. Male rhesus macaques (5.3 years old at the initiation of treatment) were induced to drink alcohol and then given the choice to voluntarily self-administer water or ethanol (4 % w/v) for approximately 14 months, followed by three abstinence phases (lasting 34, 41, and 39-46 days) with approximately 3 months of ethanol access in between. During the initial 14 months of open-access, monkeys in the alcohol group consumed an average of 2.9 ± 0.8 g/kg/d ethanol (mean ± SD) resulting in a blood ethanol concentration of 89 ± 47 mg/dl in longitudinal samples taken at 7 h after the daily sessions began. To understand the impact of alcohol consumption on material properties, various mechanical tests were conducted on the distal tibia diaphysis of 2-5 monkeys per test group, including dynamic mechanical analysis (DMA) testing, nano-indentation, microhardness testing, compression testing, and fracture resistance curve (R-curve) testing. Additionally, compositional analyses were performed using Fourier-transform infrared (FTIR) spectroscopy. Significant differences in microhardness, compressive stress-strain response, and composition were not observed with alcohol consumption, and only minor differences were detected in hardness and elastic modulus of the matrix and osteons from nanoindentation. Furthermore, the R-curves of both groups overlapped, with similar crack initiation toughness, despite a significant decrease in crack growth toughness (p = 0.032) with alcohol consumption. However, storage modulus (p = 0.029) and loss factor (p = 0.015) from DMA testing were significantly increased in the alcohol group compared to the control group, while loss modulus remained unchanged. These results indicate that heavy alcohol consumption may have only a minor influence on the material properties and the composition of cortical bone in young adult male rhesus macaques.
Collapse
Affiliation(s)
- Mihee Shin
- School of Mechanical and Manufacturing Engineering, University of New South Wales (UNSW Sydney), Sydney, NSW 2052, Australia
| | - Do Kyung Kim
- School of Mechanical and Manufacturing Engineering, University of New South Wales (UNSW Sydney), Sydney, NSW 2052, Australia; Department of Material Science and Engineering, Korea Advanced Institute of Science and Technology (KAIST), Daejeon 305-701, Republic of Korea
| | - Manish Jain
- Center for Integrated Nanotechnologies, Sandia National Laboratories, Albuquerque, NM 87123, USA
| | - Penny J Martens
- Graduate School of Biomedical Engineering, University of New South Wales (UNSW Sydney), Sydney, NSW 2052, Australia
| | - Russell T Turner
- Skeletal Biology Laboratory, School of Biological and Population Health Sciences, Oregon State University, Corvallis, 97331 Oregon, United States; Center for Healthy Aging Research, Oregon State University, Corvallis, 97331 Oregon, United States
| | - Urszula T Iwaniec
- Skeletal Biology Laboratory, School of Biological and Population Health Sciences, Oregon State University, Corvallis, 97331 Oregon, United States; Center for Healthy Aging Research, Oregon State University, Corvallis, 97331 Oregon, United States
| | - Jamie J Kruzic
- School of Mechanical and Manufacturing Engineering, University of New South Wales (UNSW Sydney), Sydney, NSW 2052, Australia
| | - Bernd Gludovatz
- School of Mechanical and Manufacturing Engineering, University of New South Wales (UNSW Sydney), Sydney, NSW 2052, Australia.
| |
Collapse
|
5
|
Amabili M, Franchini G, Asgari M, Giovanniello F, Ghayesh MH, Breslavsky ID. Active and passive mechanical characterization of a human descending thoracic aorta with Klippel-Trenaunay syndrome. J Mech Behav Biomed Mater 2023; 148:106216. [PMID: 37924665 DOI: 10.1016/j.jmbbm.2023.106216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Accepted: 10/28/2023] [Indexed: 11/06/2023]
Abstract
A human aorta from a female donor affected by Klippel-Trenaunay syndrome was retrieved during a surgery for organ donation for transplant. The aorta was preserved in refrigerated Belzer UW organ preservation solution and tested within a few hours for mechanical characterization with and without vascular smooth muscle activation. KCl and Noradrenaline were used as vasoactive agents in bubbled Krebs-Henseleit buffer solution at 37 °C. A quasi-static and a dynamic mechanical characterization of the full wall and the three individual layers were carried out for strips taken in longitudinal and circumferential directions. The full wall in the descending portion of the aorta underwent mechanical tests with and without smooth muscle activation. Results were compared to data obtained from healthy aortas and show a reduced stiffness of the full wall in circumferential direction. Also, a significant reduction of the response to vasoactive agents in circumferential direction was observed, while the longitudinal response was similar to healthy cases.
Collapse
Affiliation(s)
- Marco Amabili
- Department of Mechanical Engineering, McGill University, Montreal, H3A 0C3, Canada.
| | - Giulio Franchini
- Advanced Material Research Center, Technology Innovation Institute, Abu Dhabi, United Arab Emirates
| | - Meisam Asgari
- Department of Medical Engineering, University of South Florida, Tampa, FL, USA
| | | | - Mergen H Ghayesh
- School of Electrical and Mechanical Engineering, The University of Adelaide, Adelaide, Australia
| | - Ivan D Breslavsky
- Department of Mechanical Engineering, McGill University, Montreal, H3A 0C3, Canada
| |
Collapse
|
6
|
Jung C, Bodin F, Ruffenach L, Bruant Rodier C, Dieval F. Aging of non-implanted Natrelle™ gel breast implants. J Mech Behav Biomed Mater 2023; 147:106137. [PMID: 37806278 DOI: 10.1016/j.jmbbm.2023.106137] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2022] [Revised: 12/08/2022] [Accepted: 09/20/2023] [Indexed: 10/10/2023]
Abstract
This study questions the aging of non-implanted breast prostheses for a period of 9-60 months. Every 6 months, two non-implanted Natrelle™ prostheses were tested to measure the strength at break, the elongation at break, and the thickness of the shell. Then, the breaking stress was calculated from the preceding quantities. All these quantities were observed by separating the samples taken from the anterior and posterior sides of the prostheses. One-way ANOVA analyses (analysis of variance) were performed to define the influence of aging duration, lot membership, and side. In addition, the elongation at break and the thickness of the shell showed significant variations as a function of aging regardless of the side but without any trend emerging. For other quantities, there were significant disparities between the anterior and posterior sides of the prostheses, differences between prostheses from different lots, and similarities between prostheses from the same lot. Finally, the thickness is an important parameter. Since manufacturing is a manual process, it is necessary to check the thickness, which must be homogeneous on both sides. Always weaker on the anterior side than on the posterior side, it influences the mechanical properties. We recommend, like other studies, that its control be part of the quality controls during manufacturing.
Collapse
Affiliation(s)
- Corinne Jung
- Université de Haute-Alsace, LPMT UR 4365, F-68100, Mulhouse, France; Université de Strasbourg, France.
| | - Frédéric Bodin
- Service de Chirurgie Plastique Reconstructrice et Esthétique, Hôpitaux Universitaires de Strasbourg, Strasbourg, France.
| | - Laetitia Ruffenach
- Service de Chirurgie Plastique Reconstructrice et Esthétique, Hôpitaux Universitaires de Strasbourg, Strasbourg, France.
| | - Catherine Bruant Rodier
- Service de Chirurgie Plastique Reconstructrice et Esthétique, Hôpitaux Universitaires de Strasbourg, Strasbourg, France.
| | - Florence Dieval
- Université de Haute-Alsace, LPMT UR 4365, F-68100, Mulhouse, France; Université de Strasbourg, France.
| |
Collapse
|
7
|
Baigh TA, Nanzeeba F, Hamim HR, Habib MA. A comprehensive study on the effect of hybridization and stacking sequence in fabricating cotton-blended jute and pineapple leaf fibre biocomposites. Heliyon 2023; 9:e19792. [PMID: 37809613 PMCID: PMC10559121 DOI: 10.1016/j.heliyon.2023.e19792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Revised: 08/31/2023] [Accepted: 08/31/2023] [Indexed: 10/10/2023] Open
Abstract
Developing biocomposites by hybridization, which is the combination of two or more materials, can be a potential solution for improving material recyclability and sustainability. This study focuses on creating a hybrid biocomposite reinforced with cotton-blended pineapple leaf fibre (PALF) fabric (174 GSM) and jute fibre fabric (265 GSM) which are thrown away by textile factories. The mechanical, moisture absorption, and vibration characteristics of four stacking sequences of hybrid composites and two unhybridized composites were analyzed. Results indicated that hybridization improved tensile and flexural characteristics compared to pineapple leaf fibre reinforced polymer (PFRP) composites. The jute fibre reinforced polymer (JFRP) composite exhibited the maximum tensile strength of 35.16 MPa, while the hybrid composites achieved a maximum of 32.16 MPa. Among the hybrid composites, jute layers on the outer plies (4P5J-2) demonstrated the maximum tensile modulus of 1.315 GPa. Additionally, the hybrid composite with three layers of jute plies between alternating layers of jute-pineapple plies showed the highest elongation at 15.94%. Among the hybrids, alternate stacking of jute/PALF plies (4P5J-1) gave a maximum flexural strength of 44.36 MPa, which is similar to JFRP (44.91 MPa) and a 78.57% increase in flexural modulus compared to PFRP composite, despite having the lowest tensile strength. Although the JFRP composite exhibited the highest impact strength, the hybrids still outperformed the PFRP composites. With hybridization, moisture absorption decreased, with a maximum of 29.50% compared to the JFRP composite. Furthermore, due to the spiral-like orientation of the yarns, stacking PALF plies on the outside can cause critical damping. Therefore, it is shown in this paper that both hybridization and stacking sequence can significantly influence composite performance. These findings also implies the utilization of textile industry's natural fibres to develop hybrid composites for automotive applications, like brake and accelerator pedals, for a greener future and effective waste material utilization.
Collapse
Affiliation(s)
| | | | - Hasibur R. Hamim
- Department of Mechanical and Production Engineering, Islamic University of Technology (IUT), Gazipur, 1704, Bangladesh
| | - M. Ahsan Habib
- Department of Mechanical and Production Engineering, Islamic University of Technology (IUT), Gazipur, 1704, Bangladesh
| |
Collapse
|
8
|
Civilini V, Giacalone V, Audenino AL, Terzini M. A reliable and replicable test protocol for the mechanical evaluation of synthetic meshes. J Mech Behav Biomed Mater 2023; 144:105987. [PMID: 37413894 DOI: 10.1016/j.jmbbm.2023.105987] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 06/06/2023] [Accepted: 06/20/2023] [Indexed: 07/08/2023]
Abstract
Despite the worldwide spread of surgical meshes in abdominal and inguinal surgery repair, the lack of specific standards for mechanical characterization of synthetic meshes, used in hernia repair and urogynecologic surgery, makes performance comparison between prostheses undoubtedly difficult. This consequently leads to the absence of acknowledged specifications about the mechanical requirements that synthetic meshes should achieve in order to avoid patient discomfort or hernia recurrences. The aim of this study is to provide a rigorous test protocol for the mechanical comparison between surgical meshes having the same intended use. The test protocol is composed of three quasi-static test methods: (1) ball burst test, (2) uniaxial tensile test, and (3) suture retention test. For each test, post-processing procedures are proposed to compute relevant mechanical parameters from the raw data. Some of the computed parameters, indeed, could be more suitable for comparison with physiological conditions (e.g., membrane strain and anisotropy), while others (e.g., uniaxial tension at rupture and suture retention strength) are reported as they provide useful mechanical information and could be convenient for comparisons between devices. The proposed test protocol was applied on 14 polypropylene meshes, 3 composite meshes, and 6 urogynecologic devices to verify its universal applicability towards meshes of different types and produced by various manufacturers, and its repeatability in terms of coefficient of variation. The test protocol resulted easily applicable to all the tested surgical meshes with intra-subject variability characterized by coefficient of variations settled around 0.05. Its use within other laboratories could allow the determination of the inter-subject variability assessing its repeatability among users of alternative universal testing machines.
Collapse
Affiliation(s)
- Vittoria Civilini
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, 10129, Turin, Italy; Polito(BIO)Med Lab, Politecnico di Torino, 10129, Turin, Italy.
| | - Vincenzo Giacalone
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, 10129, Turin, Italy; Polito(BIO)Med Lab, Politecnico di Torino, 10129, Turin, Italy
| | - Alberto L Audenino
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, 10129, Turin, Italy; Polito(BIO)Med Lab, Politecnico di Torino, 10129, Turin, Italy
| | - Mara Terzini
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, 10129, Turin, Italy; Polito(BIO)Med Lab, Politecnico di Torino, 10129, Turin, Italy
| |
Collapse
|
9
|
MacManus DB. Excision of whole intact mouse brain. MethodsX 2023; 10:102246. [PMID: 37424760 PMCID: PMC10326498 DOI: 10.1016/j.mex.2023.102246] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Accepted: 06/06/2023] [Indexed: 07/11/2023] Open
Abstract
Mechanical characterization experiments of brain tissue are performed to understand the mechanical behavior of brain tissue during normal physiology and pathophysiological processes including traumatic brain injury. Normal, healthy, undamaged, unfixed brain tissue specimens are required for these mechanical characterization experiments to ensure the properties being measured are not from damaged/diseased tissue which may lead to inaccurate and unreliable results regarding the mechanical behavior of healthy undamaged brain tissue. The process of excising brain tissue from the cranial vault of mouse cadavers can induce lacerations in the tissue that may affect its mechanical behavior. Therefore, it is imperative that brain tissue samples are excised without inducing damage to the tissue so that the normal undamaged mechanical properties can be measured. Here, a method to excise the entire intact mouse brain is presented:•The scalp is resected exposing the anterior portion of the skull.•Cranial bone is resected by incising along the cranial sutures and using the scalpel blade to remove the cranial segments.•Connective tissue is resected and the brain is removed from the cranial vault.
Collapse
Affiliation(s)
- David B. MacManus
- School of Mechanical & Materials Engineering, University College Dublin, Dublin, Ireland
- BRAIN Lab, School of Mechanical & Materials Engineering, University College Dublin, Dublin, Ireland
| |
Collapse
|
10
|
Good BC. The influence of blood composition and loading frequency on the behavior of embolus analogs. J Mech Behav Biomed Mater 2023; 140:105738. [PMID: 36821909 DOI: 10.1016/j.jmbbm.2023.105738] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Revised: 02/13/2023] [Accepted: 02/17/2023] [Indexed: 02/19/2023]
Abstract
In cases of acute ischemic stroke (AIS), mechanical thrombectomy (MT) can be used to directly remove lodged thromboemboli. Despite improvements in patient outcomes, one of the key factors affecting MT success is the mechanical properties of the occlusive thrombus. Therefore, the goal of this study was to investigate the viscoelastic properties of embolus analogs (EAs) and determine the influence of EA hematocrit and loading frequency. Bovine blood EAs were created over a range of physiological hematocrits (0-60%) and cyclic uniaxial compression testing was performed at three loading frequencies to mimic in vivo loading conditions, followed by stress-relaxation testing. It was found that EAs exhibited behaviors typical of hyper-viscoelastic materials and that EA hematocrit played a large role in both EA stiffness and relaxation, with both parameters decreasing as hematocrit increased from 0 to 60%. The viscoelastic behavior of the EAs was also affected by the frequency at which they were loaded, with significant increases in peak stresses between the 0.5 and 2 Hz loaded EAs. Lower hematocrit EAs had very dense fibrin networks while the higher hematocrit EAs consisted of closely packed RBCs with little fibrin present. These results suggest that fibrin contributes to EA stiffness and relaxation behaviors while RBCs play a role in decreasing the overall viscous response and strain-rate dependency. An Ogden hyperelastic model was found to best reproduce the EA loading data while a 3-term Prony series was fit to the stress relaxation data. A hyper-viscoelastic modeling framework was then implemented combining the loading and stress-relaxation fits and the results could match the full cyclic loading data for EAs of varying hematocrit and loading frequency. The results of the experimental mechanical characterization and hyper-viscoelastic curve fitting can be incorporated in future modeling efforts to optimize mechanical thrombectomy for AIS patients.
Collapse
Affiliation(s)
- Bryan C Good
- Mechanical, Aerospace, And Biomedical Engineering, University of Tennessee, Knoxville, TN, USA.
| |
Collapse
|
11
|
Giovanniello F, Asgari M, Breslavsky ID, Franchini G, Holzapfel GA, Tabrizian M, Amabili M. Development and mechanical characterization of decellularized scaffolds for an active aortic graft. Acta Biomater 2023; 160:59-72. [PMID: 36792047 DOI: 10.1016/j.actbio.2023.02.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 02/02/2023] [Accepted: 02/07/2023] [Indexed: 02/16/2023]
Abstract
Decellularized porcine aortas are proposed as scaffolds for revolutionary active aortic grafts. A change in the static and dynamic mechanical properties, associated with the microstructure of elastin and collagen fibers, corresponds to alteration in the cyclic expansion and perfusion, in addition to possible graft damage. Therefore, the present study thoroughly investigates the mechanical response of the decellularized scaffolds of human and porcine origin to static and dynamic mechanical loads. The responses of the native human and porcine aortas are also compared; this is unavailable in the literature. Because the aorta is subjected to pulsatile blood pressure, dynamical responses to cyclic loads and their associated viscoelastic properties are particularly relevant for advanced graft design. In parallel, this study examines the microstructure of the decellularized aorta. The resulting data are compared to the analogous data obtained for the native human and porcine tissues. The results indicate that by using an optimized decellularization protocol - based on sodium dodecyl sulfate (SDS) and DNase - that minimizes mechanical and structural changes of the tissue, layered scaffolds with static and dynamic properties very similar to natural human aortas are obtained. In particular, a decellularized porcine aorta is non-inferior to a decellularized human aorta. STATEMENT OF SIGNIFICANCE: About 55,000 patients undergo abdominal aortic aneurysm repair annually in the USA. The currently implanted grafts present a large mechanical mismatch with the native tissue. This increases the pulsatile nature of the blood flow with negative consequences to the organ perfusion. For this reason, biomimetic and mechanically compatible grafts for aortic repair are urgently needed and they can be obtained through tissue engineering. In this study, scaffolds from porcine and human aortas are obtained from an optimized decellularization protocol. They are accurately compared to the native tissue and present the ideal static and dynamic mechanical properties for developing innovative aortic grafts.
Collapse
Affiliation(s)
| | - Meisam Asgari
- Department of Mechanical Engineering, McGill University, Montreal, Canada
| | - Ivan D Breslavsky
- Department of Mechanical Engineering, McGill University, Montreal, Canada
| | - Giulio Franchini
- Department of Mechanical Engineering, McGill University, Montreal, Canada
| | - Gerhard A Holzapfel
- Institute of Biomechanics, Graz University of Technology, Austria; Department of Structural Engineering, Norwegian University of Science and Technology, Trondheim, Norway
| | - Maryam Tabrizian
- Department of Biomedical Engineering, McGill University, Montreal, Canada; Faculty of Dental Medicine and Oral Health Sciences, McGill University, Montreal, Canada
| | - Marco Amabili
- Department of Mechanical Engineering, McGill University, Montreal, Canada; Advanced Materials Research Center, Technology Innovation Institute (TII), Abu Dhabi, UAE.
| |
Collapse
|
12
|
Kim Y, Yoon T, Park WB, Na S. Predicting mechanical properties of silk from its amino acid sequences via machine learning. J Mech Behav Biomed Mater 2023; 140:105739. [PMID: 36871478 DOI: 10.1016/j.jmbbm.2023.105739] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2022] [Revised: 02/12/2023] [Accepted: 02/21/2023] [Indexed: 02/25/2023]
Abstract
The silk fiber is increasingly being sought for its superior mechanical properties, biocompatibility, and eco-friendliness, making it promising as a base material for various applications. One of the characteristics of protein fibers, such as silk, is that their mechanical properties are significantly dependent on the amino acid sequence. Numerous studies have been conducted to determine the specific relationship between the amino acid sequence of silk and its mechanical properties. Still, the relationship between the amino acid sequence of silk and its mechanical properties is yet to be clarified. Other fields have adopted machine learning (ML) to establish a relationship between the inputs, such as the ratio of different input material compositions and the resulting mechanical properties. We have proposed a method to convert the amino acid sequence into numerical values for input and succeeded in predicting the mechanical properties of silk from its amino acid sequences. Our study sheds light on predicting mechanical properties of silk fiber from respective amino acid sequences.
Collapse
|
13
|
Pérez-Benito Á, Huerta-López C, Alegre-Cebollada J, García-Aznar JM, Hervas-Raluy S. Computational modelling of the mechanical behaviour of protein-based hydrogels. J Mech Behav Biomed Mater 2023; 138:105661. [PMID: 36630754 DOI: 10.1016/j.jmbbm.2023.105661] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 12/20/2022] [Accepted: 01/04/2023] [Indexed: 01/07/2023]
Abstract
Protein-based hydrogels have been extensively studied in the field of biomaterials given their ability to mimic living tissues and their special resemblance to the extracellular matrix. Despite this, the methods used for the control of mechanical properties of hydrogels are very limited, focusing mainly on their elasticity, with an often unrealistic characterization of mechanical properties such as extensibility, stiffness and viscoelasticity. Being able to control these properties is essential for the development of new biomaterials, since it has been demonstrated that mechanical properties affect cell behaviour and biological processes. To better understand the mechanical behaviour of these biopolymers, a computational model is here developed to characterize the mechanical behaviour of two different protein-based hydrogels. Strain-stress tests and stress-relaxation tests are evaluated computationally and compared to the results obtained experimentally in a previous work. To achieve this goal the Finite Element Method is used, combining hyperelastic and viscoelastic models. Different hyperelastic constitutive models (Mooney-Rivlin, Neo-Hookean, first and third order Ogden, and Yeoh) are proposed to estimate the mechanical properties of the protein-based hydrogels by least-square fitting of the in-vitro uniaxial test results. Among these models, the first order Ogden model with a viscoelastic model defined in Prony parameters better reproduces the strain-stress response and the change of stiffness with strain observed in the in-vitro tests.
Collapse
Affiliation(s)
- Ángela Pérez-Benito
- Multiscale in Mechanical and Biological Engineering, Instituto de Investigacion en Ingenieria de Aragon(I3A), University of Zaragoza, Zaragoza, 50014, Spain
| | - Carla Huerta-López
- Centro Nacional de Investigaciones Cardiovasculares (CNIC), Madrid, 28029, Spain
| | | | - José Manuel García-Aznar
- Multiscale in Mechanical and Biological Engineering, Instituto de Investigacion en Ingenieria de Aragon(I3A), University of Zaragoza, Zaragoza, 50014, Spain
| | - Silvia Hervas-Raluy
- Multiscale in Mechanical and Biological Engineering, Instituto de Investigacion en Ingenieria de Aragon(I3A), University of Zaragoza, Zaragoza, 50014, Spain.
| |
Collapse
|
14
|
Lamont S, Fropier J, Abadie J, Piat E, Constantinescu A, Roux C, Vernerey F. Profiling oocytes with neural networks from images and mechanical data. J Mech Behav Biomed Mater 2023; 138:105640. [PMID: 36566663 DOI: 10.1016/j.jmbbm.2022.105640] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2022] [Revised: 12/07/2022] [Accepted: 12/19/2022] [Indexed: 12/24/2022]
Abstract
The success rate of assisted reproductive technologies could be greatly improved by selectively choosing egg cells (oocytes) with the greatest chance of fertilization. The goal of mechanical profiling is, thus, to improve predictive oocyte selection by isolating the mechanical properties of oocytes and correlating them to their reproductive potential. The restrictions on experimental platforms, however - including minimal invasiveness and practicality in laboratory implementation - greatly limits the data that can be acquired from a single oocyte. In this study, we perform indentation studies on human oocytes and characterize the mechanical properties of the zona pellucida, the outer layer of the oocyte. We obtain excellent fitting with our physical model when indenting with a flat surface and clearly illustrate localized shear-thinning behavior of the zona pellucida, which has not been previously reported. We conclude by outlining a promising methodology for isolating the mechanical properties of the cytoplasm using neural networks and optical images taken during indentation.
Collapse
Affiliation(s)
- Samuel Lamont
- Department of Mechanical Engineering, Program of Materials Science and Engineering, University of Colorado Boulder, Boulder, CO 80309, United States of America
| | - Juliette Fropier
- Laboratoire de Mécanique des Solides - CNRS - École Polytechnique - Institut Polytechnique de Paris, 91128, Palaiseau, France
| | - Joel Abadie
- FEMTO-ST Institute, Univ. Bourgogne Franche-Comté, CNRS, 15B avenue des Montboucons, 25030 Besançon, cedex, France
| | - Emmanuel Piat
- FEMTO-ST Institute, Univ. Bourgogne Franche-Comté, CNRS, 15B avenue des Montboucons, 25030 Besançon, cedex, France
| | - Andrei Constantinescu
- Laboratoire de Mécanique des Solides - CNRS - École Polytechnique - Institut Polytechnique de Paris, 91128, Palaiseau, France
| | - Christophe Roux
- Service de Biologie et Médecine de la Reproduction - Cryobiologie - CECOS Franche-Comté Bourgogne, CHRU Jean Minjoz, 3 Bd Fleming, 25030 Besançon cedex, France
| | - Franck Vernerey
- Department of Mechanical Engineering, Program of Materials Science and Engineering, University of Colorado Boulder, Boulder, CO 80309, United States of America.
| |
Collapse
|
15
|
Dyer OL, Wheatley BB, Seeley MA. Short-term vancomycin and buffer soaking does not change rabbit achilles tendon tensile material properties. Clin Biomech (Bristol, Avon) 2023; 102:105874. [PMID: 36621306 DOI: 10.1016/j.clinbiomech.2023.105874] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/17/2022] [Revised: 12/22/2022] [Accepted: 01/03/2023] [Indexed: 01/06/2023]
Abstract
BACKGROUND Allograft tendons are commonly used during orthopedic surgery to reconstruct tissue that is severely damaged. Soaking the tendon in an antibiotic solution, specifically vancomycin, has been shown to lower the risk of post-operative infections. While some material properties of tendon and ligament after antibiotic soaking have previously been characterized, extensive sub-failure allograft tendon material properties after soaking in antibiotic solutions have not. METHODS Forty tendons were dissected from rabbits and soaked in either a phosphate buffered saline (PBS) only solution or vancomycin and PBS solution for five or 30 min. Immediately after soaking, quasi-static tensile experiments were performed in a materials testing system. FINDINGS Tissue nominal stress, Lagrange strain, toe-region properties and elastic modulus were characterized. For all forty tendons, the average elastic modulus was found to be 455 ± 37 MPa, the average transition strain (from toe-region to linear elastic region) was 0.0487 ± 0.0035, and the average transition stress was 9.71 ± 0.79 MPa. No statistically significant differences in any of these material properties were found across soaking medium or soaking time. INTERPRETATION From these results, we conclude that soaking an allograft tendon in antibiotic solution for up to 30 min prior to implantation does not change the tensile material properties of tendons, supporting current clinical practice.
Collapse
Affiliation(s)
- Olivia L Dyer
- Musculoskeletal Institute, Geisinger, Danville, PA, United States of America.
| | - Benjamin B Wheatley
- Department of Mechanical Engineering, Bucknell University, Lewisburg, PA, United States of America.
| | - Mark A Seeley
- Musculoskeletal Institute, Geisinger, Danville, PA, United States of America.
| |
Collapse
|
16
|
McCarthy CM, Allardyce JM, Hickey SE, Walsh MT, McGourty KD, Mulvihill JJE. Comparison of macroscale and microscale mechanical properties of fresh and fixed-frozen porcine colonic tissue. J Mech Behav Biomed Mater 2023; 138:105599. [PMID: 36462287 DOI: 10.1016/j.jmbbm.2022.105599] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 11/21/2022] [Accepted: 11/23/2022] [Indexed: 11/27/2022]
Abstract
Mechanical changes to the microenvironment of the extracellular matrix (ECM) in tissue have been hypothesised to elicit a pathogenic response in the surrounding cells. Hence, 3D scaffolds are a popular method of studying cellular behaviour under conditions that mimic in vivo microenvironment. To create a 3D biomimetic scaffold that captures the in vivo ECM microenvironment a robust mechanical characterisation of the whole ECM at the microscale is necessary. This study examined the multiscale methods of characterising the ECM microenvironment using porcine colon tissue. To facilitate fresh tissue microscale mechanical characterisation, a protocol for sectioning fresh, unfixed, soft biological tissue was developed. Four experiments examined both the microscale and macroscale mechanics of both fresh (Fr) and fixed-frozen (FF) porcine colonic tissue using microindentation for microscale testing and uniaxial compression testing for macroscale testing. The results obtained in this study show a significant difference in elastic modulus between Fr and FF tissue at both the macroscale and microscale. There was an order of magnitude difference between the Fr and FF tissue at the microscale between each of the three layers of the colon tested i.e. the muscularis propria (MP), the submucosa (SM) and the mucosa (M). Macroscale testing cannot capture these regional differences. The findings in this study suggest that the most appropriate method for mechanically characterising the ECM is fresh microscale mechanical microindentation. These methods can be used on a range of biological tissues to create 3D biomimetic scaffolds that are more representative of the in vivo ECM, allowing for a more in-depth characterisation of the disease process.
Collapse
Affiliation(s)
- Clíona M McCarthy
- Biomaterials Cluster, Bernal Institute, University of Limerick, Limerick, Ireland; School of Engineering, University of Limerick, Limerick, Ireland
| | - Joanna M Allardyce
- School of Allied Health, University of Limerick, Ireland; Health Research Institute, University of Limerick, Ireland
| | - Séamus E Hickey
- Biomaterials Cluster, Bernal Institute, University of Limerick, Limerick, Ireland; School of Chemical Sciences, University of Limerick, Ireland
| | - Michael T Walsh
- Biomaterials Cluster, Bernal Institute, University of Limerick, Limerick, Ireland; School of Engineering, University of Limerick, Limerick, Ireland; Health Research Institute, University of Limerick, Ireland
| | - Kieran D McGourty
- Biomaterials Cluster, Bernal Institute, University of Limerick, Limerick, Ireland; School of Chemical Sciences, University of Limerick, Ireland; Health Research Institute, University of Limerick, Ireland
| | - John J E Mulvihill
- Biomaterials Cluster, Bernal Institute, University of Limerick, Limerick, Ireland; School of Engineering, University of Limerick, Limerick, Ireland; Health Research Institute, University of Limerick, Ireland.
| |
Collapse
|
17
|
Elahi SA, Castro-Viñuelas R, Govaerts A, Lories R, Famaey N, Jonkers I. Unconfined Compression Experimental Protocol for Cartilage Explants and Hydrogel Constructs: From Sample Preparation to Mechanical Characterization. Methods Mol Biol 2023; 2598:271-287. [PMID: 36355298 DOI: 10.1007/978-1-0716-2839-3_19] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Mechanical characterization of articular cartilage and cell-seeded hydrogel constructs is a challenging task due to the complex biphasic behavior of these materials. Here we describe a step-by-step unconfined compression testing protocol for inverse mechanical characterization of these materials from sample preparation to parameter identification. Examples from our ongoing experiments on alginate hydrogel constructs and preserved and damaged cartilage explants obtained from human hip samples are presented.
Collapse
Affiliation(s)
- Seyed Ali Elahi
- Human Movement Biomechanics Research Group, Department of Movement Sciences, KU Leuven, Leuven, Belgium.
- Soft Tissue Biomechanics Group, Biomechanics Division, Mechanical Engineering Department, KU Leuven, Leuven, Belgium.
| | - Rocío Castro-Viñuelas
- Human Movement Biomechanics Research Group, Department of Movement Sciences, KU Leuven, Leuven, Belgium
- Tissue homeostasis and Disease Group, Skeletal Biology and Engineering Research Center, Department of Development and Regeneration, KU Leuven, Leuven, Belgium
| | - Anke Govaerts
- Human Movement Biomechanics Research Group, Department of Movement Sciences, KU Leuven, Leuven, Belgium
- Tissue homeostasis and Disease Group, Skeletal Biology and Engineering Research Center, Department of Development and Regeneration, KU Leuven, Leuven, Belgium
| | - Rik Lories
- Tissue homeostasis and Disease Group, Skeletal Biology and Engineering Research Center, Department of Development and Regeneration, KU Leuven, Leuven, Belgium
| | - Nele Famaey
- Soft Tissue Biomechanics Group, Biomechanics Division, Mechanical Engineering Department, KU Leuven, Leuven, Belgium
| | - Ilse Jonkers
- Human Movement Biomechanics Research Group, Department of Movement Sciences, KU Leuven, Leuven, Belgium
| |
Collapse
|
18
|
Vieweg U, Keck J, Krüger S, Arabmotlagh M, Rauschmann M, Schilling C. Biomechanical comparison of different rod-to-rod connectors to a conventional titanium- and cobalt chromium posterior spinal fixation system. Brain Spine 2022; 3:101708. [PMID: 36685708 PMCID: PMC9845396 DOI: 10.1016/j.bas.2022.101708] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Revised: 10/28/2022] [Accepted: 12/20/2022] [Indexed: 12/24/2022]
Abstract
Introduction Several types of rod-to-rod connectors are available for the extension of spinal fixation systems. However, scientific literature regarding the mechanical performance of different rod-to-rod connector systems is lacking. Research question The goal of this study was to evaluate the mechanical characteristics of axial and lateral rod connectors in comparison to a conventional pedicle screw rod (titanium and cobalt chromium) construct. Material and method Six types of instrumentations were investigated in a standardized test model to quantify the mechanical differences: 1: titanium rod; 2: titanium rod with axial connector; 3: titanium rod with lateral connector; 4: cobalt chromium rod; 5: cobalt chromium rod with axial connector; 6: cobalt chromium rod with lateral connector. All groups were tested in static compression, static torsion and dynamic compression and statistically compared regarding failure load and stiffness. Results In static compression loading, the use of connectors increased the construct stiffness, but unaffected the yield load. The use of a cobalt chromium rod significantly increased by approximately 40% the yield load and stiffness in comparison to the titanium rod configurations. Under dynamic compression, a similar or higher fatigue strength for all tested groups in comparison to the titanium rod configuration was evaluated, with the exception of titanium rod with axial connector. Conclusion Biomechanically, using rod connectors is a secure way for the extension of a construct and is mechanically equal to a conventional screw rod construct. However, in clinical use, attention should be paid regarding placement of the connectors at high loaded areas.
Collapse
Affiliation(s)
- Uwe Vieweg
- Krankenhaus Rummelsberg, Department of Surgical and Conservative Spine Therapy, Rummelsberg, Germany
| | - Johannes Keck
- Krankenhaus Rummelsberg, Department of Surgical and Conservative Spine Therapy, Rummelsberg, Germany
| | - Sven Krüger
- Aesculap AG, Research & Development, Tuttlingen, Germany
| | | | - Michael Rauschmann
- Sana Klinikum Offenbach, Department of Spine Surgery, Offenbach, Germany
| | - Christoph Schilling
- Aesculap AG, Research & Development, Tuttlingen, Germany,Corresponding author. Am Aesculap-Platz, 78532, Tuttlingen, Germany.
| |
Collapse
|
19
|
Aryeetey OJ, Frank M, Lorenz A, Estermann SJ, Reisinger AG, Pahr DH. A parameter reduced adaptive quasi-linear viscoelastic model for soft biological tissue in uniaxial tension. J Mech Behav Biomed Mater 2022; 126:104999. [PMID: 34999491 DOI: 10.1016/j.jmbbm.2021.104999] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 11/04/2021] [Accepted: 11/24/2021] [Indexed: 11/15/2022]
Abstract
Mechanical characterisation of soft viscous materials is essential for many applications including aerospace industries, material models for surgical simulation, and tissue mimicking materials for anatomical models. Constitutive material models are, therefore, necessary to describe soft biological tissues in physiologically relevant strain ranges. Hereby, the adaptive quasi-linear viscoelastic (AQLV) model enables accurate modelling of the strain-dependent non-linear viscoelastic behaviour of soft tissues with a high flexibility. However, the higher flexibility produces a large number of model parameters. In this study, porcine muscle and liver tissue samples were modelled in the framework of the originally published AQLV (3-layers of Maxwell elements) model using four incremental ramp-hold experiments in uniaxial tension. AQLV model parameters were reduced by decreasing model layers (M) as well as the number of experimental ramp-hold steps (N). Leave One out cross validation tests show that the original AQLV model (3M4N) with 19 parameters, accurately describes porcine muscle tissue with an average R2 of 0.90 and porcine liver tissue, R2 of 0.86. Reducing the number of layers (N) in the model produced acceptable model fits for 1-layer (R2 of 0.83) and 2-layer models (R2 of 0.89) for porcine muscle tissue and 1-layer (R2 of 0.84) and 2-layer model (R2 of 0.85) for porcine liver tissue. Additionally, a 2 step (2N) ramp-hold experiment was performed on additional samples of porcine muscle tissue only to further reduce model parameters. Calibrated spring constant values for 2N ramp-hold tests parameters k1 and k2 had a 16.8% and 38.0% deviation from those calibrated for a 4 step (4N) ramp hold experiment. This enables further reduction of material parameters by means of step reduction, effectively reducing the number of parameters required to calibrate the AQLV model from 19 for a 3M4N model to 8 for a 2M2N model, with the added advantage of reducing the time per experiment by 50%. This study proposes a 'reduced-parameter' AQLV model (2M2N) for the modelling of soft biological tissues at finite strain ranges. Sequentially, the comparison of model parameters of soft tissues is easier and the experimental burden is reduced.
Collapse
Affiliation(s)
- Othniel J Aryeetey
- TU Wien, Institute of Lightweight Design and Structural Biomechanics, Gumpendorfer Straße 7, 1060, Vienna, Austria; Karl Landsteiner University of Health Sciences, Department of Anatomy and Biomechanics, Division Biomechanics, Dr. Karl-Dorrek-Straße 30, 3500, Krems, Austria
| | - Martin Frank
- Karl Landsteiner University of Health Sciences, Department of Anatomy and Biomechanics, Division Biomechanics, Dr. Karl-Dorrek-Straße 30, 3500, Krems, Austria
| | - Andrea Lorenz
- Austrian Center for Medical Innovation & Technology (ACMIT), Viktor Kaplan-Straße 2/1, 2700, Wiener Neustadt, Austria
| | - Sarah-Jane Estermann
- TU Wien, Institute of Lightweight Design and Structural Biomechanics, Gumpendorfer Straße 7, 1060, Vienna, Austria; Karl Landsteiner University of Health Sciences, Department of Anatomy and Biomechanics, Division Biomechanics, Dr. Karl-Dorrek-Straße 30, 3500, Krems, Austria; Austrian Center for Medical Innovation & Technology (ACMIT), Viktor Kaplan-Straße 2/1, 2700, Wiener Neustadt, Austria
| | - Andreas G Reisinger
- TU Wien, Institute of Lightweight Design and Structural Biomechanics, Gumpendorfer Straße 7, 1060, Vienna, Austria; Karl Landsteiner University of Health Sciences, Department of Anatomy and Biomechanics, Division Biomechanics, Dr. Karl-Dorrek-Straße 30, 3500, Krems, Austria
| | - Dieter H Pahr
- TU Wien, Institute of Lightweight Design and Structural Biomechanics, Gumpendorfer Straße 7, 1060, Vienna, Austria; Karl Landsteiner University of Health Sciences, Department of Anatomy and Biomechanics, Division Biomechanics, Dr. Karl-Dorrek-Straße 30, 3500, Krems, Austria.
| |
Collapse
|
20
|
Amabili M, Asgari M, Breslavsky ID, Franchini G, Giovanniello F, Holzapfel GA. Microstructural and mechanical characterization of the layers of human descending thoracic aortas. Acta Biomater 2021; 134:401-421. [PMID: 34303867 DOI: 10.1016/j.actbio.2021.07.036] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2021] [Revised: 07/10/2021] [Accepted: 07/15/2021] [Indexed: 12/13/2022]
Abstract
The mechanical properties of human aortas are linked to the layered tissue and its microstructure at different length scales. Each layer has specific mechanical and structural properties. While the ground substance and the elastin play an important role in tissue stiffness at small strain, collagen fibers carry most of the load at larger strains, which corresponds to the physiological conditions of the aorta at maximum pulsatile blood pressure. In fact, collagen fibers are crimped in the unloaded state. Collagen fibers show different orientation distributions when they are observed in a plane that is tangent to the aortic wall (in-plane section) or along a direction orthogonal to it (out-of-plane section). This was systematically investigated using large images (2500 × 2500 µm) with high resolution obtained by second harmonic generation (SHG) in order to homogenize tissue heterogeneity after a convergence analysis, which is a main goal of the study. In addition, collagen fibers show lateral interactions due to entanglements and the presence of transverse elastin fibers, observed on varying length scales using atomic force microscopy and a three-dimensional rendering obtained by stacking a sequence of SHG and two-photon fluorescence images; this is another important contribution. Human descending thoracic aortas from 13 heartbeat donors aged 28 to 66 years were examined. Uniaxial tensile tests were carried out on the longitudinal and circumferential strips of the aortic wall and the three separated layers (intima, media and adventitia). A structurally-motivated material model with (i) a term to describe the combined response of ground substance and elastin and (ii) terms to consider four families of collagen fibers with different directions was applied. The exclusion of compressed fibers was implemented in the fitting process of the experimental data, which was optimized by a genetic algorithm. The results show that a single fiber family with directional and dispersion parameters measured from SHG images can describe the mechanical response of all 39 layers (3 layers for each of the 13 aortas) with very good accuracy when a second (auxiliary) family of aligned fibers is introduced in the orthogonal direction to account for lateral fiber interaction. Indeed, all observed distributions of collagen directions can be accurately fitted by a single bivariate von Mises distribution. Statistical analysis of in-plane and out-of-plane dispersion of fiber orientations reveals structural differences between the three layers and a change of collagen dispersion parameters with age. STATEMENT OF SIGNIFICANCE: The stiffness of healthy young aortas is adjusted so that a diameter expansion of about 10 % is possible during the heartbeat. This creates the Windkessel effect, which smooths out the pulsating nature of blood flow and benefits organ perfusion. The specific elastic properties of the aorta that are required to achieve this effect are related to the microstructure of the aortic tissue at different length scales. An increase in the aortic stiffness, in addition to reducing cyclic expansion and worsening perfusion, is a risk factor for clinical hypertension. The present study relates the microstructure of healthy human aortas to the mechanical response and examines the changes in microstructural parameters with age, which is a key factor in increasing stiffness.
Collapse
|
21
|
Guarnera D, Carrera E, Hansen CJ, Maiarù M. Mechanical characterization of 3D printed mimic of human artery affected by atherosclerotic plaque through numerical and experimental methods. Biomech Model Mechanobiol 2021; 20:1969-1980. [PMID: 34227022 DOI: 10.1007/s10237-021-01487-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Accepted: 06/28/2021] [Indexed: 10/20/2022]
Abstract
This paper proposes a novel experimental investigation based on 3D printing to validate numerical models for biomechanics simulations. Soft elastomeric materials have been used in Polyjet multi-material 3D printer to mimicking arteries affected by atherosclerotic plaque. The nonlinear mechanical properties of five digital materials are characterized and used as an input for finite element (FE) modeling. Pressurized air is applied to the internal cavity of the printed model to reproduce the internal blood pressure in the artery. Digital Imaging Correlation is adopted to measure the displacement and deformation. A 1D linear higher-order FE model based on the Carrera Unified Formulation is compared to 3D nonlinear FE solutions.
Collapse
Affiliation(s)
- Daniele Guarnera
- The BioRobotics Institute - Scuola Superiore Sant'Anna, Pisa, Italy
| | - Erasmo Carrera
- Mechanical and Aerospace Engineering Department, Politecnico di Torino, Turin, Italy
| | | | - Marianna Maiarù
- Department of Mechanical Engineering, UMASS Lowell, Lowell, MA, USA.
| |
Collapse
|
22
|
Bianco G, Levy AM, Grytz R, Fazio MA. Effect of different preconditioning protocols on the viscoelastic inflation response of the posterior sclera. Acta Biomater 2021; 128:332-345. [PMID: 33932581 DOI: 10.1016/j.actbio.2021.04.042] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2020] [Revised: 04/18/2021] [Accepted: 04/20/2021] [Indexed: 12/11/2022]
Abstract
Preconditioning by repeated cyclic loads is routinely used in ex vivo mechanical testing of soft biological tissues. The goal of preconditioning is to achieve a steady and repeatable mechanical response and to measure material properties that are representative of the in vivo condition. Preconditioning protocols vary across studies, and their effect on the viscoelastic response of tested soft tissue is typically not reported or analyzed. We propose a methodology to systematically analyze the preconditioning process with application to inflation testing. We investigated the effect of preconditioning on the viscoelastic inflation response of tree shrew posterior sclera using two preconditioning protocols: (i) continuous cyclic loading-unloading without rest and (ii) cyclic loading-unloading with 15-min rest between cycles. Posterior scleral surface strain was measured using three-dimensional Digital Image Correlation (3D-DIC). We used five variables of characterizing features of the stress-strain loop curve to compare the two preconditioning protocols. Our results showed protocol-dependent differences in the tissue response during preconditioning and at the preconditioned state. Incorporating a resting time between preconditioning cycles significantly decreased the number of cycles (10.5 ± 2.9 cycles vs. 3.1 ± 0.5 cycles, p < 0.001) but increased the total time (15.8 ± 4.4 min vs. 51.2 ± 8.3 min, p < 0.001) needed to reach preconditioned state. At the preconditioned state, 2 of 5 characteristic variables differed significantly between protocols: hysteresis loop area (difference=0.023 kJ/m3, p = 0.0020) and elastic modulus at high IOPs (difference=24.0 MPa, p = 0.0238). Our results suggest that the analysis of the preconditioning process is an essential part of inflation experiments and a prerequisite to properly characterize the tissue viscoelastic response. Furthermore, material properties obtained at the preconditioned state can be impacted by the resting time used during preconditioning and may not be directly compared across studies if the resting time varies by 15 min between studies. STATEMENT OF SIGNIFICANCE: Although applying a preconditioning protocol by repeated cyclic loads is common practice in ex vivo mechanical characterization of soft tissues, the tissue response is typically not reported or analyzed, and the protocol's potential effect on the response remains unclear. This is partially caused by lack of a standardized methodology to precondition soft tissues. We present the first systematic analysis of two representative preconditioning protocols used during inflation testing in ocular biomechanics. Our results show protocol-dependent differences in the viscoelastic response during the preconditioning process and at the preconditioned state. Consequently, the analysis of the preconditioning response represents an essential part of mechanical testing and a prerequisite to properly characterize the tissue viscoelastic response. The effect of preconditioning on the preconditioned state response must be considered when comparing results across studies with different preconditioning protocols.
Collapse
|
23
|
Grasl C, Stoiber M, Röhrich M, Moscato F, Bergmeister H, Schima H. Electrospinning of small diameter vascular grafts with preferential fiber directions and comparison of their mechanical behavior with native rat aortas. Mater Sci Eng C Mater Biol Appl 2021; 124:112085. [PMID: 33947575 DOI: 10.1016/j.msec.2021.112085] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Revised: 03/09/2021] [Accepted: 03/29/2021] [Indexed: 11/21/2022]
Abstract
Conventional electrospun small diameter vascular grafts have a random fiber orientation. In order to achieve mechanical characteristics similar to a native blood vessel, a controllable fiber orientation is of interest. In this study the electrospinning jet was directly controlled by means of an auxiliary, changeable electrostatic field, so that the fibers could be deposited in adjustable orientations. Prostheses with circumferentially, axially, fenestrated and randomly aligned fibers were electrospun on Ø2mm mandrels out of a thermoplastic polyurethane (PUR) and a polylactid acid (PLLA). The impact of the materials and the various preferential fiber orientations on the resulting biomechanics was investigated and compared with that of the native rat aorta in quasistatic and dynamic hoop tensile tests. The test protocol included 3000 dynamic loading cycles in the physiological blood pressure range and ended with a quasistatic tensile test. Any orientation of the fibers in a particular direction resulted in a significant reduction in scaffold porosity for both materials. The standard randomly oriented PUR grafts showed the highest compliance of 29.7 ± 5.5 [%/100 mmHg] and were thus closest to the compliance of the rat aortas, which was 37.2 ± 6.5 [%/100 mmHg]. The maximum tensile force was increased at least 6 times compared to randomly spun grafts by orienting the fibers in the circumferential direction. During the 3000 loading cycles, creeping of the native rat aorta was below 1% whereas the electrospun grafts showed creeping up to 2.4 ± 1.2%. Although the preferred fiber orientations were only partially visible in the scanning electron micrographs, the mechanical effects were evident. The investigations suggest a multi-layer wall structure of the vascular prosthesis, since none of the preferred fiber directions and the materials used could imitate the typical j-shaped mechanical characteristics of the rat aorta.
Collapse
|
24
|
Boussès Y, Brulat-Bouchard N, Bouchard PO, Tillier Y. A numerical, theoretical and experimental study of the effect of thermocycling on the matrix-filler interface of dental restorative materials. Dent Mater 2021; 37:772-782. [PMID: 33608140 DOI: 10.1016/j.dental.2021.01.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 01/20/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVE Thermocycling is widely used to age dental composites but with very different results from one study to another, even with apparent similar conditions. This study aims at understanding better the relative damaging speed of matrix and fillers, based on theoretical models. METHODS Eight formulations of an experimental dental material were produced. The same organic matrix was used and silanated barium glass particles were added as fillers with different filler ratios. Samples were thermocycled up to 10 000 cycles. Three-point bending tests were carried out at different steps. The yield stress was measured among other mechanical properties. RESULTS Composite properties were degraded by thermocycling. The decrease was slight during the first 5 000 cycles whereas it decreased significantly after 10 000 cycles. The Turcsányi model asserts that the interface yield stress is slightly affected in the first 5 000 cycles and then falls down, while the decrease of matrix yield stress is linear. SIGNIFICANCE Each component of a composite does not age at the same rate. First, the matrix acts as a protector until the water finds its way to the interphase. The filler silanization treatment is highly sensitive to hydrolysis and is damaged rapidly from that moment. Numerical simulations and surface observations confirmed that cracks appear to propagate in the neighbourhood of the interface but not directly within it.
Collapse
Affiliation(s)
- Yoan Boussès
- CEMEF Centre de Mise En Forme des Matériaux, MINES ParisTech, PSL Research University, UMR CNRS 7635, Sophia Antipolis, CS10 207, France.
| | - Nathalie Brulat-Bouchard
- CEMEF Centre de Mise En Forme des Matériaux, MINES ParisTech, PSL Research University, UMR CNRS 7635, Sophia Antipolis, CS10 207, France; UFR d'Odontologie Nice Côte d'Azur, Université Nice Sophia Antipolis, Nice, France
| | - Pierre-Olivier Bouchard
- CEMEF Centre de Mise En Forme des Matériaux, MINES ParisTech, PSL Research University, UMR CNRS 7635, Sophia Antipolis, CS10 207, France
| | - Yannick Tillier
- CEMEF Centre de Mise En Forme des Matériaux, MINES ParisTech, PSL Research University, UMR CNRS 7635, Sophia Antipolis, CS10 207, France
| |
Collapse
|
25
|
Flügel K, Schmidt K, Mareczek L, Gäbe M, Hennig R, Thommes M. Impact of incorporated drugs on material properties of amorphous solid dispersions. Eur J Pharm Biopharm 2021; 159:88-98. [PMID: 33383170 DOI: 10.1016/j.ejpb.2020.12.017] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2020] [Revised: 12/19/2020] [Accepted: 12/21/2020] [Indexed: 11/16/2022]
Abstract
Formulation development of amorphous solid dispersions (ASD) still is challenging although several poorly water-soluble drugs have been marketed using this technique. During development of novel drugs, the selection of the preparation technique and polymer matrix is commonly performed for the certain drug via screening tools. However, if general trends regarding material properties are to be investigated, this approach is not beneficial, although often utilized in literature. The main component of the ASD usually is the polymer and thus it predominantly determines the material properties of the system. Therefore, to study the impact of different drugs and their drug loads on mechanical properties and wettability, three poorly soluble model drugs with drug loads ranging from 10% to 40% were incorporated into copovidone via hot-melt extrusion. The obtained extrudates were subsequently characterized regarding mechanical properties by applying diametral compression test and nanoindentation and the results were compared to the performance during tablet compression. Incorporation of all tested drugs resulted in a similar increase in brittleness of the ASDs, whereas the Young's modulus and hardness changed differently in dependence of the incorporated drug. These observations correlated well with the performance during tablet compression and it was concluded, that the brittleness seemed to be the predominant factor influencing the compression behavior of copovidone-based ASDs. Furthermore, the degree of water absorption and wettability was assessed by applying dynamic vapor sorption experiments and contact angle measurements. Here, the incorporated drugs impacted the contact angle to different degrees and a strong correlation between the contact angle and disintegration time was observable. These results highlight the importance of thorough characterization of the ASDs as it helps to predict their performance during tablet compression and thus facilitates the optimal selection of excipients.
Collapse
Affiliation(s)
- Karsten Flügel
- Faculty of Biochemical and Chemical Engineering, Laboratory of Solids Process Engineering, Technical University Dortmund, Emil-Figge-Str. 68, 44227 Dortmund, Germany; Department of Pharmaceutical Technologies, Merck KGaA, Frankfurter Str. 250, 64293 Darmstadt, Germany
| | - Katharina Schmidt
- Department of Pharmaceutical Technologies, Merck KGaA, Frankfurter Str. 250, 64293 Darmstadt, Germany
| | - Lena Mareczek
- Department of Pharmaceutical Technologies, Merck KGaA, Frankfurter Str. 250, 64293 Darmstadt, Germany
| | - Michael Gäbe
- Department of Pharmaceutical Technologies, Merck KGaA, Frankfurter Str. 250, 64293 Darmstadt, Germany
| | - Robert Hennig
- Department of Pharmaceutical Technologies, Merck KGaA, Frankfurter Str. 250, 64293 Darmstadt, Germany
| | - Markus Thommes
- Faculty of Biochemical and Chemical Engineering, Laboratory of Solids Process Engineering, Technical University Dortmund, Emil-Figge-Str. 68, 44227 Dortmund, Germany.
| |
Collapse
|
26
|
van Kampen KA, Olaret E, Stancu IC, Moroni L, Mota C. Controllable four axis extrusion-based additive manufacturing system for the fabrication of tubular scaffolds with tailorable mechanical properties. Mater Sci Eng C Mater Biol Appl 2020; 119:111472. [PMID: 33321595 DOI: 10.1016/j.msec.2020.111472] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2020] [Revised: 06/21/2020] [Accepted: 07/13/2020] [Indexed: 11/17/2022]
Abstract
Many tubular tissues such as blood vessels and trachea can suffer long-segmental defects through trauma and disease. With current limitations in the use of autologous grafts, the need for a synthetic substitute is of continuous interest as possible alternatives. Fabrication of these tubular organs is commonly done with techniques such as electrospinning and melt electrowriting using a rotational collector. Current additive manufacturing (AM) systems do not commonly implement the use of a rotational axis, which limits their application for the fabrication of tubular scaffolds. In this study, a four axis extrusion-based AM system similar to fused deposition modeling (FDM) has been developed to create tubular hollow scaffolds. A rectangular and a diamond pore design were further investigated for mechanical characterization, as a standard and a biomimicry pore geometry respectively. We demonstrated that in the radial compression mode the diamond pore design had a higher Young's modulus (19,8 ± 0,7 MPa compared to 2,8 ± 0,5 MPa), while in the longitudinal tensile mode the rectangular pore design had a higher Young's modulus (5,8 ± 0,2 MPa compared to 0,1 ± 0,01 MPa). Three-point bending analyses revealed that the diamond pore design is more resistant to luminal collapse compared to the rectangular design. This data showed that by changing the scaffold pore design, a wide range of mechanical properties could be obtained. Furthermore, a full control over scaffold design and geometry can be achieved with the developed 4-axis extrusion-based system, which has not been reported with other techniques. This flexibility allow the manufacturing of scaffolds for diverse tubular tissue regeneration applications by designing suitable deposition patterns to match their mechanical pre-requisites.
Collapse
Affiliation(s)
- Kenny A van Kampen
- Department of Complex Tissue Regeneration, MERLN Institute for Technology-Inspired Regenerative Medicine, Maastricht University, Universiteitsingel 40, 6229ER Maastricht, the Netherlands
| | - Elena Olaret
- Advanced Polymer Materials Group, University Politehnica of Bucharest, 1-7 Gh. Polizu Street, 011061 Bucharest, Romania
| | - Izabela-Cristina Stancu
- Advanced Polymer Materials Group, University Politehnica of Bucharest, 1-7 Gh. Polizu Street, 011061 Bucharest, Romania
| | - Lorenzo Moroni
- Department of Complex Tissue Regeneration, MERLN Institute for Technology-Inspired Regenerative Medicine, Maastricht University, Universiteitsingel 40, 6229ER Maastricht, the Netherlands
| | - Carlos Mota
- Department of Complex Tissue Regeneration, MERLN Institute for Technology-Inspired Regenerative Medicine, Maastricht University, Universiteitsingel 40, 6229ER Maastricht, the Netherlands.
| |
Collapse
|
27
|
Vignali E, di Bartolo F, Gasparotti E, Malacarne A, Concistré G, Chiaramonti F, Murzi M, Positano V, Landini L, Celi S. Correlation between micro and macrostructural biaxial behavior of ascending thoracic aneurysm: a novel experimental technique. Med Eng Phys 2020; 86:78-85. [PMID: 33261737 DOI: 10.1016/j.medengphy.2020.10.012] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2020] [Revised: 10/01/2020] [Accepted: 10/21/2020] [Indexed: 02/08/2023]
Abstract
Mechanical properties and microstructural modifications of vessel tissues are strongly linked, as established in the state of the art of cardiovascular diseases. Techniques to obtain both mechanical and structural information are reported, but the possibility to obtain real-time microstructural and macrostructural data correlated is still lacking. An experimental approach to characterize the aortic tissue is presented. A setup integrating biaxial traction and Small Angle Light Scattering (SALS) analysis is described. The system was adopted to test ex-vivo aorta specimens from healthy and aneusymatic (aTAA) cases. A significant variation of the fiber dispersion with respect to the unloaded state was encountered during the material traction. The corresponding microstructural and mechanical data were successfully used to fit a given anisotropic constitutive model, with satisfactory R2 values (0.97±0.11 and 0.96±0.17, for aTAA and healthy population, respectively) and fiber dispersion parameters variations between the aTAA and healthy populations (0.39±0.23 and 0.15±0.10). The method integrating the biaxial/SALS technique was validated, allowing for real-time synchronization between mechanical and microstructural analysis of anisotropic biological tissues.
Collapse
Affiliation(s)
- Emanuele Vignali
- BioCardioLab, Ospedale del Cuore, Fondazione Toscana G. Monasterio, Massa, Italy; Department of Information Engineering, University of Pisa, Pisa, Italy
| | - Francesco di Bartolo
- BioCardioLab, Ospedale del Cuore, Fondazione Toscana G. Monasterio, Massa, Italy; Department of Information Engineering, University of Pisa, Pisa, Italy
| | - Emanuele Gasparotti
- BioCardioLab, Ospedale del Cuore, Fondazione Toscana G. Monasterio, Massa, Italy; Department of Information Engineering, University of Pisa, Pisa, Italy
| | | | - Giovanni Concistré
- Adult Cardiosurgery Unit, Ospedale del Cuore, Fondazione Toscana Gabriele Monasterio, Massa, Italy
| | - Francesca Chiaramonti
- Adult Cardiosurgery Unit, Ospedale del Cuore, Fondazione Toscana Gabriele Monasterio, Massa, Italy
| | - Michele Murzi
- Adult Cardiosurgery Unit, Ospedale del Cuore, Fondazione Toscana Gabriele Monasterio, Massa, Italy
| | - Vincenzo Positano
- BioCardioLab, Ospedale del Cuore, Fondazione Toscana G. Monasterio, Massa, Italy
| | - Luigi Landini
- Department of Information Engineering, University of Pisa, Pisa, Italy
| | - Simona Celi
- BioCardioLab, Ospedale del Cuore, Fondazione Toscana G. Monasterio, Massa, Italy.
| |
Collapse
|
28
|
Aparicio-Rojas GM, Medina-Vargas G, Díaz-Puentes E. Thermal, structural and mechanical characterization of Nephila clavipes spider silk in southwest Colombia. Heliyon 2020; 6:e05262. [PMID: 33204867 PMCID: PMC7649264 DOI: 10.1016/j.heliyon.2020.e05262] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2019] [Revised: 08/27/2020] [Accepted: 10/12/2020] [Indexed: 12/03/2022] Open
Abstract
Some physical properties of spider silks, including mechanical strength and toughness, have been studied in many laboratories worldwide. Given that this silk is organic in nature, composed of protein, and has similar properties to metal wires or polymers, it has the potential for application in medicine, nanoelectronics, and other related areas. In this study, we worked on spider silk from the Nephila clavipes species collected from the wild and kept it in the nursery of the Autonomous University of the West, Cali, Colombia, to determine its physical, thermal, and mechanical properties, seeking possible applications in the medical and industrial sectors and comparing the material properties of the silk from the species from southwestern Colombia with those of the previously studied species from other regions. The mechanical characterization of the material was performed using a universal testing machine; thermal behavior was captured by a thermogravimetric analysis, differential scanning calorimetry, and mass spectrometry; and structural characterization was performed using diffraction X-rays. The results of the thermal characterization demonstrate that the spider silk loses 10 % of water content at 150 °C with significant changes at 400 °C, while the mechanical characterization indicates that the spider silk is much tougher than Kevlar 49 and Nylon 6 since it is capable of absorbing more energy before rupture.
Collapse
|
29
|
Li D, Chen ZX, Zhang YM, Li XC, Meng M, He L, Zhang ZZ. Improved reliability of mechanical behavior for a thermal tempered lithium disilicate glass-ceramic by regulating the cooling rate. J Mech Behav Biomed Mater 2020; 114:104191. [PMID: 33254008 DOI: 10.1016/j.jmbbm.2020.104191] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Revised: 10/26/2020] [Accepted: 10/27/2020] [Indexed: 10/23/2022]
Abstract
Traditional thermal tempering was applied to lithium disilicate (LD) glass-ceramic specimens with bar-like and disc-like shapes. The tempering process was conducted by heating the specimens to a temperature below the dynamic softening point, and then rapid cooling in silicone oil with different temperatures ranging from room-temperature to 300 °C to regulate the cooling rate. Effect of the oil-temperature on mechanical behavior of the tempered glass-ceramic was investigated. For the tempering at the lower oil-temperature (e.g., at room-temperature), it was found that the LD glass-ceramic specimens with both the bar-like and disc-like shapes could be remarkably strengthen and toughen, however, obvious anisotropy in fracture toughness was displayed by the specimens with the bar-like shape. With increasing the oil-temperature up to 250 °C, the mechanical anisotropy of the bar-like specimens could be significantly alleviated without much loss of the strengthening effect. The results can provide references for improving reliability of mechanical behavior for the tempered LD glass-ceramic by regulating the cooling condition according to specimen geometry.
Collapse
Affiliation(s)
- D Li
- School of Science, Xi'an University of Posts and Telecommunications, Xi'an, 710121, China
| | - Z X Chen
- State Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, 710049, China
| | - Y M Zhang
- School of Science, Xi'an University of Posts and Telecommunications, Xi'an, 710121, China
| | - X C Li
- State Key Laboratory for Mechanical Behavior of Materials, Xi'an Jiaotong University, Xi'an, 710049, China
| | - M Meng
- State Key Laboratory of Military Stomatology, Department of Prosthodontics, School of Stomatology, Fourth Military Medical University, Xi'an, 710032, China
| | - L He
- State Key Laboratory for Mechanical Behavior of Materials, Xi'an Jiaotong University, Xi'an, 710049, China.
| | - Z Z Zhang
- State Key Laboratory of Military Stomatology, Department of Prosthodontics, School of Stomatology, Fourth Military Medical University, Xi'an, 710032, China.
| |
Collapse
|
30
|
Vieira JC, Mendes AO, Carta AM, Fiadeiro PT, Costa AP. Experimental dataset supporting the physical and mechanical characterization of industrial base tissue papers. Data Brief 2020; 33:106434. [PMID: 33145380 DOI: 10.1016/j.dib.2020.106434] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 10/08/2020] [Accepted: 10/14/2020] [Indexed: 11/29/2022] Open
Abstract
Tissue paper is defined by its physical and mechanical properties, namely: high softness, low grammage, high bulk and high liquid absorption capacity. It is expected that the production of tissue paper will continue to grow, which increases the importance of better understanding the processes involved in its production as well as its optimization [1]. The experimental data presented in this article, are the physical-mechanical characterization of a group of 13 industrial base tissue papers, which were collected at the end of the tissue paper machine on Portuguese factories. These samples vary in grammage, composition and creping [2], enabling a later evaluation of the crepe type [3] and its relationship with the final properties of the tissue paper.
Collapse
|
31
|
Flügel K, Hennig R, Thommes M. Impact of structural relaxation on mechanical properties of amorphous polymers. Eur J Pharm Biopharm 2020; 154:214-221. [PMID: 32702377 DOI: 10.1016/j.ejpb.2020.07.016] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Revised: 07/07/2020] [Accepted: 07/15/2020] [Indexed: 11/18/2022]
Abstract
Fusion based methods, such as hot-melt extrusion, are a common way of preparing amorphous solid dispersions. Since the amorphous glass, however, is not in a configurational equilibrium, the molecular arrangement of the obtained material can differ in dependence of the preparation conditions. Although the changes in the configuration of an amorphous material, which are commonly referred to as structural relaxation or physical aging, are well investigated, the impact on mechanical properties of amorphous solid dispersions have widely been neglected so far. The presented study investigated copovidone as a model polymer commonly used in amorphous solid dispersions and revealed that structural relaxation was already introduced into the polymer during hot-melt extrusion while its degree was cooling rate dependent. The degree of structural relaxation significantly affected the mechanical properties of copovidone as assessed by diametral compression tests, macroindentation and nanoindentation. An increase in Young's modulus and indentation hardness was observable with a higher degree of structural relaxation, which, during tablet compression, translated into tablets with significantly lower tensile strength. Furthermore, evaluation of the force-displacement curves during tablet compression revealed a decreased proportion of irreversible deformation with higher degree of structural relaxation correlating well with the increased indentation hardness during macroindentation. Thus, understanding structural relaxation and its impact on material properties is of utmost importance to assess the processability and compaction performance of amorphous solid dispersions in dependence of their preparation conditions and thermal history.
Collapse
Affiliation(s)
- Karsten Flügel
- Department of Biochemical and Chemical Engineering, Laboratory of Solids Process Engineering, Technical University Dortmund, Emil-Figge-Str. 68, 44227 Dortmund, Germany; Department of Pharmaceutical Technologies, Merck Healthcare KGaA, Frankfurter Str. 250, 64293 Darmstadt, Germany
| | - Robert Hennig
- Department of Pharmaceutical Technologies, Merck Healthcare KGaA, Frankfurter Str. 250, 64293 Darmstadt, Germany
| | - Markus Thommes
- Department of Biochemical and Chemical Engineering, Laboratory of Solids Process Engineering, Technical University Dortmund, Emil-Figge-Str. 68, 44227 Dortmund, Germany.
| |
Collapse
|
32
|
Abstract
Tensile testing is widely used to evaluate the mechanical properties of biological materials including soft primary plant tissues. Commercially available platforms for tensile testing are often expensive and limited in customizability. In this chapter, we provide a guide for the assembly and use of a simple and low-cost micromechanical testing apparatus suitable for research and educational purposes. The build of the setup is presented with scalability and universality in mind and is based on a do-it-yourself mind frame towards mechanical tests on plant organs and tissues. We discuss hardware and software requirements with practical details on required components, device calibration and a script to run the device. Further, we provide an example in which the device was used for the uniaxial tensile test of onion epidermis.
Collapse
|
33
|
Wang M, Liu S, Xu Z, Qu K, Li M, Chen X, Xue Q, Genin GM, Lu TJ, Xu F. Characterizing poroelasticity of biological tissues by spherical indentation: an improved theory for large relaxation. J Mech Phys Solids 2020; 138:103920. [PMID: 33132418 PMCID: PMC7595329 DOI: 10.1016/j.jmps.2020.103920] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Flow of fluids within biological tissues often meets with resistance that causes a rate- and size-dependent material behavior known as poroelasticity. Characterizing poroelasticity can provide insight into a broad range of physiological functions, and is done qualitatively in the clinic by palpation. Indentation has been widely used for characterizing poroelasticity of soft materials, where quantitative interpretation of indentation requires a model of the underlying physics, and such existing models are well established for cases of small strain and modest force relaxation. We showed here that existing models are inadequate for large relaxation, where the force on the indenter at a prescribed depth at long-time scale drops to below half of the initially peak force (i.e., F(0)/F(∞) > 2). We developed an indentation theory for such cases of large relaxation, based on Biot theory and a generalized Hertz contact model. We demonstrated that our proposed theory is suitable for biological tissues (e.g., spleen, kidney, skin and human cirrhosis liver) with both small and large relaxations. The proposed method would be a powerful tool to characterize poroelastic properties of biological materials for various applications such as pathological study and disease diagnosis.
Collapse
Affiliation(s)
- Ming Wang
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Shaanxi, 710049, P.R. China
- Bioinspired Engineering & Biomechanics Center (BEBC), Xi’an Jiaotong University, Xi’an 710049, P.R. China
- State Key Laboratory of Mechanics and Control of Mechanical Structures, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, P.R. China
| | - Shaobao Liu
- State Key Laboratory of Mechanics and Control of Mechanical Structures, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, P.R. China
- Nanjing Center for Multifunctional Lightweight Materials and Structures, Nanjing University of Aeronautics and Astronautics, Nanjing 21006, P.R. China
| | - Zhimin Xu
- State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace, Xi’an Jiaotong University, Xi’an 710049, P.R. China
| | - Kai Qu
- Bioinspired Engineering & Biomechanics Center (BEBC), Xi’an Jiaotong University, Xi’an 710049, P.R. China
- Department of Hepatobiliary Surgery, The First Affiliated Hospital of Xi’an Jiaotong University, Xi’an 710061, China
| | - Moxiao Li
- Bioinspired Engineering & Biomechanics Center (BEBC), Xi’an Jiaotong University, Xi’an 710049, P.R. China
- State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace, Xi’an Jiaotong University, Xi’an 710049, P.R. China
| | - Xin Chen
- Bioinspired Engineering & Biomechanics Center (BEBC), Xi’an Jiaotong University, Xi’an 710049, P.R. China
- State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace, Xi’an Jiaotong University, Xi’an 710049, P.R. China
| | - Qing Xue
- Bioinspired Engineering & Biomechanics Center (BEBC), Xi’an Jiaotong University, Xi’an 710049, P.R. China
- State Key Laboratory for Strength and Vibration of Mechanical Structures, School of Aerospace, Xi’an Jiaotong University, Xi’an 710049, P.R. China
| | - Guy M. Genin
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Shaanxi, 710049, P.R. China
- Bioinspired Engineering & Biomechanics Center (BEBC), Xi’an Jiaotong University, Xi’an 710049, P.R. China
- National Science Foundation Science and Technology Center for Engineering Mechanobiology, Washington University, St. Louis, MO 63130, USA
| | - Tian Jian Lu
- State Key Laboratory of Mechanics and Control of Mechanical Structures, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, P.R. China
- Nanjing Center for Multifunctional Lightweight Materials and Structures, Nanjing University of Aeronautics and Astronautics, Nanjing 21006, P.R. China
| | - Feng Xu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Shaanxi, 710049, P.R. China
- Bioinspired Engineering & Biomechanics Center (BEBC), Xi’an Jiaotong University, Xi’an 710049, P.R. China
| |
Collapse
|
34
|
Davidson CD, Jayco DKP, Matera DL, DePalma SJ, Hiraki HL, Wang WY, Baker BM. Myofibroblast activation in synthetic fibrous matrices composed of dextran vinyl sulfone. Acta Biomater 2020; 105:78-86. [PMID: 31945504 PMCID: PMC7369643 DOI: 10.1016/j.actbio.2020.01.009] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2019] [Revised: 12/18/2019] [Accepted: 01/08/2020] [Indexed: 02/07/2023]
Abstract
Mechanical interactions between fibroblasts and their surrounding extracellular matrix (ECM) guide fundamental behaviors such as spreading, migration, and proliferation that underlie disease pathogenesis. The challenges of studying ECM mechanics in vivo have motivated the development of in vitro models of the fibrous ECM in which fibroblasts reside. Natural materials such as collagen hydrogels bear structural and biochemical resemblance to stromal ECM, but mechanistic studies in these settings are often confounded by cell-mediated material degradation and the lack of structural and mechanical tunability. Here, we established a new material system composed of electrospun dextran vinyl sulfone (DexVS) polymeric fibers. These fibrous matrices exhibit mechanical tunability at both the single fiber (80-340 MPa) and bulk matrix (0.77-11.03 kPa) level, as well as long-term stability in mechanical properties over a two-week period. Cell adhesion to these matrices can be either user-defined by functionalizing synthetic fibers with thiolated adhesive peptides or methacrylated heparin to sequester cell-derived ECM proteins. We utilized DexVS fibrous matrices to investigate the role of matrix mechanics on the activation of fibroblasts into myofibroblasts, a key step of the fibrotic progression. In contrast to previous findings with non-fibrous hydrogel substrates, we find that fibroblasts in soft and deformable matrices exhibit increased spreading, focal adhesion formation, proliferation, and myofibroblast activation as compared to cells on stiffer matrices with equivalent starting architecture. STATEMENT OF SIGNIFICANCE: Cellular mechanosensing of fibrillar extracellular matrices plays a critical role in homeostasis and disease progression in stromal connective tissue. Here, we established a new material system composed of electrospun dextran vinyl sulfone polymeric fibers. These matrices exhibit architectural, mechanical, and biochemical tunability to accurately model diverse tissue microenvironments found in the body. In contrast to previous observations with non-fibrous hydrogels, we find that fibroblasts in soft and deformable fibrous matrices exhibit increased spreading and focal adhesion formation as compared to those in stiffer matrices with equivalent architecture. We also investigated the role of matrix stiffness on myofibroblast activation, a critical step in the fibrotic cascade, and find that low stiffness matrices promote increased myofibroblast activation.
Collapse
Affiliation(s)
- Christopher D Davidson
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, United States
| | - Danica Kristen P Jayco
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, United States
| | - Daniel L Matera
- Department of Chemical Engineering, University of Michigan, Ann Arbor, MI 48109, United States
| | - Samuel J DePalma
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, United States
| | - Harrison L Hiraki
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, United States
| | - William Y Wang
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, United States
| | - Brendon M Baker
- Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, United States.
| |
Collapse
|
35
|
Lainović T, Margueritat J, Martinet Q, Dagany X, Blažić L, Pantelić D, Rabasović MD, Krmpot AJ, Dehoux T. Micromechanical imaging of dentin with Brillouin microscopy. Acta Biomater 2020; 105:214-222. [PMID: 31988041 DOI: 10.1016/j.actbio.2020.01.035] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2019] [Revised: 01/20/2020] [Accepted: 01/21/2020] [Indexed: 01/10/2023]
Abstract
The structure of teeth can be altered by diet, age or diseases such as caries and sclerosis. It is very important to characterize their mechanical properties to predict and understand tooth decay, design restorative dental procedures, and investigate their tribological behavior. However, existing imaging techniques are not well suited to investigating the micromechanics of teeth, in particular at tissue interfaces. Here, we describe a microscope based on Brillouin light scattering (BLS) developed to probe the spectrum of the light scattered from tooth tissues, from which the mechanical properties (sound velocity, viscosity) can be inferred with a priori knowledge of the refractive index. BLS is an inelastic process that uses the scattering of light by acoustic waves in the GHz range. Our microscope thus reveals the mechanical properties at the micrometer scale without contact with the sample. BLS signals show significant differences between sound tissues and pathological lesions, and can be used to precisely delineate carious dentin. We also show maps of the sagittal and transversal planes of sound tubular dentin that reveal its anisotropic microstructure at 1 µm resolution. Our observations indicate that the collagen-based matrix of dentine is the main load-bearing structure, which can be considered as a fiber-reinforced composite. In the vicinity of polymeric tooth-filling materials, we observed the infiltration of the adhesive complex into the opened tubules of sound dentine. The ability to probe the quality of this interfacial layer could lead to innovative designs of biomaterials used for dental restorations in contemporary adhesive dentistry, with possible direct repercussions on decision-making during clinical work. STATEMENT OF SIGNIFICANCE: Mechanical properties of teeth can be altered by diet, age or diseases. Yet existing imaging modalities cannot reveal the micromechanics of the tooth. Here we developed a new type of microscope that uses the scattering of a laser light by naturally-occurring acoustic waves to probe mechanical changes in tooth tissues at a sub-micrometer scale without contact to the sample. We observe significant mechanical differences between healthy tissues and pathological lesions. The contrast in mechanical properties also reveals the microstructure of the polymer-dentin interfaces. We believe that this new development of laser spectroscopy is very important because it should lead to innovative designs of biomaterials used for dental restoration, and allow delineating precisely destructed dentin for minimally-invasive strategies.
Collapse
|
36
|
Vos BE, Martinez-Torres C, Burla F, Weisel JW, Koenderink GH. Revealing the molecular origins of fibrin's elastomeric properties by in situ X-ray scattering. Acta Biomater 2020; 104:39-52. [PMID: 31923718 DOI: 10.1016/j.actbio.2020.01.002] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 01/02/2020] [Accepted: 01/02/2020] [Indexed: 01/01/2023]
Abstract
Fibrin is an elastomeric protein forming highly extensible fiber networks that provide the scaffold of blood clots. Here we reveal the molecular mechanisms that explain the large extensibility of fibrin networks by performing in situ small angle X-ray scattering measurements while applying a shear deformation. We simultaneously measure shear-induced alignment of the fibers and changes in their axially ordered molecular packing structure. We show that fibrin networks exhibit distinct structural responses that set in consecutively as the shear strain is increased. They exhibit an entropic response at small strains (<5%), followed by progressive fiber alignment (>25% strain) and finally changes in the fiber packing structure at high strain (>100%). Stretching reduces the fiber packing order and slightly increases the axial periodicity, indicative of molecular unfolding. However, the axial periodicity changes only by 0.7%, much less than the 80% length increase of the fibers, suggesting that fiber elongation mainly stems from uncoiling of the natively disordered αC-peptide linkers that laterally bond the molecules. Upon removal of the load, the network structure returns to the original isotropic state, but the fiber structure becomes more ordered and adopts a smaller packing periodicity compared to the original state. We conclude that the hierarchical packing structure of fibrin fibers, with built-in disorder, makes the fibers extensible and allows for mechanical annealing. Our results provide a basis for interpreting the molecular basis of haemostatic and thrombotic disorders associated with clotting and provide inspiration to design resilient bio-mimicking materials. STATEMENT OF SIGNIFICANCE: Fibrin provides structural integrity to blood clots and is also widely used as a scaffold for tissue engineering. To fulfill their biological functions, fibrin networks have to be simultaneously compliant like skin and resilient against rupture. Here, we unravel the structural origin underlying this remarkable mechanical behaviour. To this end, we performed in situ measurements of fibrin structure across multiple length scales by combining X-ray scattering with shear rheology. Our findings show that fibrin sustains large strains by undergoing a sequence of structural changes on different scales with increasing strain levels. This demonstrates new mechanistic aspects of an important biomaterial's structure and its mechanical function, and serves as an example in the design of biomimicking materials.
Collapse
|
37
|
Zhang W, Chen Y, Hou Y, Wang W, Liu H, Zheng L. Subsurface imaging of rigid particles buried in a polymer matrix based on atomic force microscopy mechanical sensing. Ultramicroscopy 2019; 207:112832. [PMID: 31473533 DOI: 10.1016/j.ultramic.2019.112832] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2018] [Revised: 07/12/2019] [Accepted: 08/23/2019] [Indexed: 11/22/2022]
Abstract
Several subsurface imaging methods based on atomic force microscopy (AFM) linear nanomechanical mapping, namely contact resonance (CR), bimodal and harmonic AFMs, are investigated and compared. Their respective subsurface detection capability is estimated and evaluated on a model specimen, which is prepared by embedding SiO2 microparticles in a PDMS elastomer. The measured CR frequency, bimodal and harmonic amplitudes are related to local mechanical properties by analyzing cantilever dynamics and further linked to subsurface depths of the particles by finite element analysis. The maximum detectable depths are obtained from the apparent particle diameters in subsurface image channels via employing a simple geometrical model. Under common experimental settings, results demonstrate that the depth limits reach up to about 812 nm, 212 nm and 127 nm for CR, bimodal and harmonic AFM modes, respectively. The depth sensitivity can be tuned and optimized by using either different cantilever eigenmodes in CR-AFM or spectroscopy analysis in bimodal and harmonic AFMs. The three imaging methods have their own suitable application situations. The comparisons can advance a further step into understanding the subsurface image contrast via AFM mechanical sensing.
Collapse
|
38
|
Felfelian AM, Baradaran Najar A, Jafari Nedoushan R, Salehi H. Determining constitutive behavior of the brain tissue using digital image correlation and finite element modeling. Biomech Model Mechanobiol 2019; 18:1927-1945. [PMID: 31197510 DOI: 10.1007/s10237-019-01186-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2019] [Accepted: 06/05/2019] [Indexed: 11/27/2022]
Abstract
Detailed knowledge about the mechanical properties of brain can improve numerical modeling of the brain under various loading conditions. The success of this modeling depends on constitutive model and reliable extraction of its material constants. The isotropy of the brain tissue is a key factor which affects the form of constitutive models. In this study, compression tests were performed on different parts of the sheep brain tissue. Also, the digital image correlation (DIC) method was utilized to investigate the direction dependency of brain parts considering their microstructures. To this aim, the DIC method was employed to measure the transverse strain of two lateral sides of the tissue samples. The results of DIC method revealed that the brain stem and corona radiata were isotropic, while the mixed white and gray matter showed an unrepeatable behavior depending on the extracted sample. To examine and validate DIC method, stress-strain diagrams were also used to investigate the isotropy. It could be concluded that axonal fibers had no reinforcing role in the brain tissue. Furthermore, the DIC method indicated incompressibility of the brain tissue. Then, the significance of using a correct method to extract the material constants of brain was discussed. In other words, the effect of the real boundary conditions in experiments, which was neglected in most previous studies, was taken into account here. Finally, the particle swarm optimization algorithm along with the finite element modeling was used to estimate the hyper-viscoelastic constants of different parts of the brain tissue.
Collapse
Affiliation(s)
- Amir Mohammad Felfelian
- Department of Mechanical Engineering, Isfahan University of Technology, Isfahan, 84156-83111, Iran
| | | | - Reza Jafari Nedoushan
- Department of Mechanical Engineering, Isfahan University of Technology, Isfahan, 84156-83111, Iran.
| | - Hossein Salehi
- Department of Anatomical Sciences, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
| |
Collapse
|
39
|
Darvish A, Lee JS, Peng B, Saharia J, Sundaram RVK, Goyal G, Bandara N, Ahn CW, Kim J, Dutta P, Chaiken I, Kim MJ. Mechanical characterization of HIV-1 with a solid-state nanopore sensor. Electrophoresis 2019; 40:776-783. [PMID: 30151981 PMCID: PMC7400684 DOI: 10.1002/elps.201800311] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2018] [Revised: 08/13/2018] [Accepted: 08/14/2018] [Indexed: 12/15/2022]
Abstract
Enveloped viruses fuse with cells to transfer their genetic materials and infect the host cell. Fusion requires deformation of both viral and cellular membranes. Since the rigidity of viral membrane is a key factor in their infectivity, studying the rigidity of viral particles is of great significance in understating viral infection. In this paper, a nanopore is used as a single molecule sensor to characterize the deformation of pseudo-type human immunodeficiency virus type 1 at sub-micron scale. Non-infective immature viruses were found to be more rigid than infective mature viruses. In addition, the effects of cholesterol and membrane proteins on the mechanical properties of mature viruses were investigated by chemically modifying the membranes. Furthermore, the deformability of single virus particles was analyzed through a recapturing technique, where the same virus was analyzed twice. The findings demonstrate the ability of nanopore resistive pulse sensing to characterize the deformation of a single virus as opposed to average ensemble measurements.
Collapse
Affiliation(s)
- Armin Darvish
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA, USA
| | - Jung Soo Lee
- Department of Mechanical Engineering, Southern Methodist University, Dallas, TX, USA
| | - Bin Peng
- Department of Mechanical Engineering, Southern Methodist University, Dallas, TX, USA
| | - Jugal Saharia
- Department of Mechanical Engineering, Southern Methodist University, Dallas, TX, USA
| | - Ramalingam Venkat Kalyana Sundaram
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA, USA
- Department of Biochemistry and Molecular Biology, Drexel University College of Medicine, Philadelphia, PA, USA
| | | | - Nuwan Bandara
- Department of Mechanical Engineering, Southern Methodist University, Dallas, TX, USA
| | - Chi Won Ahn
- Nano-Materials Laboratory, National NanoFab Center, Daejeon, Republic of Korea
| | - Jungsuk Kim
- Department of Biomedical Engineering, Gachon University, Incheon, Republic of Korea
| | - Prashanta Dutta
- School of Mechanical and Materials Engineering, Washington State University, Pullman, WA, USA
| | - Irwin Chaiken
- Department of Biochemistry and Molecular Biology, Drexel University College of Medicine, Philadelphia, PA, USA
| | - Min Jun Kim
- Department of Mechanical Engineering, Southern Methodist University, Dallas, TX, USA
| |
Collapse
|
40
|
Wahlsten A, Pensalfini M, Stracuzzi A, Restivo G, Hopf R, Mazza E. On the compressibility and poroelasticity of human and murine skin. Biomech Model Mechanobiol 2019; 18:1079-1093. [PMID: 30806838 DOI: 10.1007/s10237-019-01129-1] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2018] [Accepted: 02/09/2019] [Indexed: 01/09/2023]
Abstract
A total of 37 human and 33 murine skin samples were subjected to uniaxial monotonic, cyclic, and relaxation experiments. Detailed analysis of the three-dimensional kinematic response showed that skin volume is significantly reduced as a consequence of a tensile elongation. This behavior is most pronounced in monotonic but persists in cyclic tests. The dehydration associated with volume loss depends on the osmolarity of the environment, so that tension relaxation changes as a consequence of modifying the ionic strength of the environmental bath. Similar to ex vivo observations, complementary in vivo stretching experiments on human volar forearms showed strong in-plane lateral contraction. A biphasic homogenized model is proposed which allows representing all relevant features of the observed mechanical response.
Collapse
Affiliation(s)
- Adam Wahlsten
- Department of Mechanical and Process Engineering, Institute for Mechanical Systems, ETH Zurich, 8092, Zurich, Switzerland.
| | - Marco Pensalfini
- Department of Mechanical and Process Engineering, Institute for Mechanical Systems, ETH Zurich, 8092, Zurich, Switzerland
| | - Alberto Stracuzzi
- Department of Mechanical and Process Engineering, Institute for Mechanical Systems, ETH Zurich, 8092, Zurich, Switzerland
| | - Gaetana Restivo
- Department of Dermatology, University Hospital Zurich, 8091, Zurich, Switzerland
| | - Raoul Hopf
- Department of Mechanical and Process Engineering, Institute for Mechanical Systems, ETH Zurich, 8092, Zurich, Switzerland.,Empa, Swiss Federal Laboratories for Materials Science and Technology, 8600, Dübendorf, Switzerland
| | - Edoardo Mazza
- Department of Mechanical and Process Engineering, Institute for Mechanical Systems, ETH Zurich, 8092, Zurich, Switzerland. .,Empa, Swiss Federal Laboratories for Materials Science and Technology, 8600, Dübendorf, Switzerland.
| |
Collapse
|
41
|
Abstract
Compared to the outer dura mater, the mechanical behavior of spinal pia and arachnoid meningeal layers has received very little attention in the literature. This is despite experimental evidence of their importance with respect to the overall spinal cord stiffness and recovery following compression. Accordingly, inclusion of the mechanical contribution of the pia and arachnoid maters would improve the predictive accuracy of finite element models of the spine, especially in the distribution of stresses and strain through the cord's cross-section. However, to-date, only linearly elastic moduli for what has been previously identified as spinal pia mater is available in the literature. This study is the first to quantitatively compare the viscoelastic behavior of isolated spinal pia-arachnoid-complex, neural tissue of the spinal cord parenchyma, and intact construct of the two. The results show that while it only makes up 5.5% of the overall cross-sectional area, the thin membranes of the innermost meninges significantly affect both the elastic and viscous response of the intact construct. Without the contribution of the pia and arachnoid maters, the spinal cord has very little inherent stiffness and experiences significant relaxation when strained. The ability of the fitted non-linear viscoelastic material models of each condition to predict independent data within experimental variability supports their implementation into future finite element computational studies of the spine. STATEMENT OF SIGNIFICANCE The neural tissue of the spinal cord is surrounded by three fibrous layers called meninges which are important in the behavior of the overall spinal-cord-meningeal construct. While the mechanical properties of the outermost layer have been reported, the pia mater and arachnoid mater have received considerably less attention. This study is the first to directly compare the behavior of the isolated neural tissue of the cord, the isolated pia-arachnoid complex, and the construct of these individual components. The results show that, despite being very thin, the inner meninges significantly affect the elastic and time-dependent response of the spinal cord, which may have important implications for studies of spinal cord injury.
Collapse
Affiliation(s)
- Nicole L Ramo
- School of Biomedical Engineering, Colorado State University, Fort Collins, CO, USA
| | - Kevin L Troyer
- Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA
| | - Christian M Puttlitz
- School of Biomedical Engineering, Colorado State University, Fort Collins, CO, USA; Department of Mechanical Engineering, Colorado State University, Fort Collins, CO, USA; Department of Clinical Sciences, Colorado State University, Fort Collins, CO, USA.
| |
Collapse
|
42
|
Afshar M, Pourkamali Anaraki A, Montazerian H. Compressive characteristics of radially graded porosity scaffolds architectured with minimal surfaces. Mater Sci Eng C Mater Biol Appl 2018; 92:254-67. [PMID: 30184749 DOI: 10.1016/j.msec.2018.06.051] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/27/2017] [Revised: 05/02/2018] [Accepted: 06/25/2018] [Indexed: 02/04/2023]
Abstract
Scaffolds with gradient pore characteristics have received a great deal of attention as they can better mimic the structure of the native tissues and concurrently meet both biological and mechanical requirements. In the present study, the effects of porosity geometry and porosity gradient patterns on the deformation mechanism and compressive mechanical properties of the structures were investigated in the context of stretching (I-WP and P surfaces) versus bending dominated (D surface) triply periodic minimal surface (TPMS) based architectures. Different gradient patterns were found to significantly alter the deformation mechanism. Radial gradient patterns (perpendicular to loading direction) provide higher deformability while longitudinally graded scaffolds suffer from low failure strain. In the stretching dominated architectures vertical cracks propagated under compression due to the materials transverse expansion under compression. Deformations in the bending dominated architectures, however, were accompanied by a progressive collapse owing to the shearing of the struts. In general, stretching dominated structures showed the higher mechanical properties and provided more efficiency under mechanical loads. Finite Element simulations also demonstrated a high capability for predicting the deformation as well as mechanical responses (especially for elastic properties) and can be used as a tool for designing multifunctional gradient porous scaffolds.
Collapse
|
43
|
Mijailovic AS, Qing B, Fortunato D, Van Vliet KJ. Characterizing viscoelastic mechanical properties of highly compliant polymers and biological tissues using impact indentation. Acta Biomater 2018; 71:388-397. [PMID: 29477455 DOI: 10.1016/j.actbio.2018.02.017] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2017] [Revised: 01/19/2018] [Accepted: 02/15/2018] [Indexed: 01/24/2023]
Abstract
Precise and accurate measurement of viscoelastic mechanical properties becomes increasingly challenging as sample stiffness decreases to elastic moduli <1 kPa, largely due to difficulties detecting initial contact with the compliant sample surface. This limitation is particularly relevant to characterization of biological soft tissues and compliant gels. Here, we employ impact indentation which, in contrast to shear rheology and conventional indentation, does not require contact detection a priori, and present a novel method to extract viscoelastic moduli and relaxation time constants directly from the impact response. We first validate our approach by using both impact indentation and shear rheology to characterize polydimethylsiloxane (PDMS) elastomers of stiffness ranging from 100 s of Pa to nearly 10 kPa. Assuming a linear viscoelastic constitutive model for the material, we find that the moduli and relaxation times obtained from fitting the impact response agree well with those obtained from fitting the rheological response. Next, we demonstrate our validated method on hydrated, biological soft tissues obtained from porcine brain, murine liver, and murine heart, and report the equilibrium shear moduli, instantaneous shear moduli, and relaxation time constants for each tissue. Together, our findings provide a new and straightforward approach capable of probing local mechanical properties of highly compliant viscoelastic materials with millimeter scale spatial resolution, mitigating complications involving contact detection or sample geometric constraints. STATEMENT OF SIGNIFICANCE Characterization and optimization of mechanical properties can be essential for the proper function of biomaterials in diverse applications. However, precise and accurate measurement of viscoelastic mechanical properties becomes increasingly difficult with increased compliance (particularly for elastic moduli <1 kPa), largely due to challenges detecting initial contact with the compliant sample surface and measuring response at short timescale or high frequency. By contrast, impact indentation has highly accurate contact detection and can be used to measure short timescale (glassy) response. Here, we demonstrate an experimental and analytical method that confers significant advantages over existing approaches to extract spatially resolved viscoelastic moduli and characteristic time constants of biological tissues (e.g., brain and heart) and engineered biomaterials.
Collapse
Affiliation(s)
- Aleksandar S Mijailovic
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Bo Qing
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Daniel Fortunato
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA
| | - Krystyn J Van Vliet
- Department of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Department of Materials Science and Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA.
| |
Collapse
|
44
|
Astruc L, De Meulaere M, Witz JF, Nováček V, Turquier F, Hoc T, Brieu M. Characterization of the anisotropic mechanical behavior of human abdominal wall connective tissues. J Mech Behav Biomed Mater 2018; 82:45-50. [PMID: 29567529 DOI: 10.1016/j.jmbbm.2018.03.012] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2017] [Revised: 03/05/2018] [Accepted: 03/09/2018] [Indexed: 11/30/2022]
Abstract
Abdominal wall sheathing tissues are commonly involved in hernia formation. However, there is very limited work studying mechanics of all tissues from the same donor which prevents a complete understanding of the abdominal wall behavior and the differences in these tissues. The aim of this study was to investigate the differences between the mechanical properties of the linea alba and the anterior and posterior rectus sheaths from a macroscopic point of view. Eight full-thickness human anterior abdominal walls of both genders were collected and longitudinal and transverse samples were harvested from the three sheathing connective tissues. The total of 398 uniaxial tensile tests was conducted and the mechanical characteristics of the behavior (tangent rigidities for small and large deformations) were determined. Statistical comparisons highlighted heterogeneity and non-linearity in behavior of the three tissues under both small and large deformations. High anisotropy was observed under small and large deformations with higher stress in the transverse direction. Variabilities in the mechanical properties of the linea alba according to the gender and location were also identified. Finally, data dispersion correlated with microstructure revealed that macroscopic characterization is not sufficient to fully describe behavior. Microstructure consideration is needed. These results provide a better understanding of the mechanical behavior of the abdominal wall sheathing tissues as well as the directions for microstructure-based constitutive model.
Collapse
Affiliation(s)
- Laure Astruc
- Univ. Lille, CNRS, Centrale Lille, FRE 2016 - LaMcube - Laboratoire de mécanique multiphysique multiéchelle, F-59000 Lille, France.
| | - Maurice De Meulaere
- Laboratoire d'Anatomie, CHRU de Lille, 1 Place de Verdun, 59045 Lille, France
| | - Jean-François Witz
- Univ. Lille, CNRS, Centrale Lille, FRE 2016 - LaMcube - Laboratoire de mécanique multiphysique multiéchelle, F-59000 Lille, France
| | - Vit Nováček
- Medtronic, Sofradim Production, 116 avenue du Formans, 01600 Trévoux, France
| | - Frédéric Turquier
- Medtronic, Sofradim Production, 116 avenue du Formans, 01600 Trévoux, France
| | - Thierry Hoc
- LTDS, UMR CNRS 5513, Université de Lyon, École Centrale de Lyon, 36 av Guy de Collongue, 69134 Écully Cedex, France
| | - Mathias Brieu
- Univ. Lille, CNRS, Centrale Lille, FRE 2016 - LaMcube - Laboratoire de mécanique multiphysique multiéchelle, F-59000 Lille, France
| |
Collapse
|
45
|
Rodríguez-Martínez A, de la Casa-Lillo MÁ, Svilainis L, Gomez Álvarez-Arenas TE. Characterization of nanoparticles doped composites using ultrasound. Ultrasonics 2018; 83:68-79. [PMID: 28673662 DOI: 10.1016/j.ultras.2017.06.017] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2017] [Revised: 04/29/2017] [Accepted: 06/19/2017] [Indexed: 06/07/2023]
Abstract
The aim of this work is the non-destructive automatic mechanical characterization of nanoparticles doped composites using ultrasound in order to understand and control the dispersion of the dopant nanoparticles in the final product. We present a method which is able to measure the elastic constants of composites (Youngs, Bulk, Shear Modulus and Poissons ratio), in addition to other parameters as density, sound velocity and thickness, providing information of the nanoparticles dispersion in the samples. All results are obtained with a single ultrasonic measure at each point of the samples' surface in an immersion setup with both pulse-echo and through-transmission measurements simultaneously, obtaining detailed information for all the samples' surface in a XY scanning. All the analysis is performed automatically, that is, no manual correction or adjustment is needed at any stage of the process. To validate the results, a polyester based resin has been analyzed with different concentrations of graphene nanoparticles as dopant. The method has shown to be very accurate and reliable. The resolution of the values obtained for the elastic constants is limited by the resolution in the velocities measurements, for which we have achieved a resolution in the order of cm/s, thus providing very accurate measurements of the elastic constants.
Collapse
Affiliation(s)
| | | | - Linas Svilainis
- Electronic Engineering Dept., KTU, Studentu St. 48, LT-51367 Kaunas, Lithuania.
| | | |
Collapse
|
46
|
Maggi A, Li H, Greer JR. Three-dimensional nano-architected scaffolds with tunable stiffness for efficient bone tissue growth. Acta Biomater 2017; 63:294-305. [PMID: 28923538 DOI: 10.1016/j.actbio.2017.09.007] [Citation(s) in RCA: 52] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2017] [Revised: 08/19/2017] [Accepted: 09/07/2017] [Indexed: 01/25/2023]
Abstract
The precise mechanisms that lead to orthopedic implant failure are not well understood; it is believed that the micromechanical environment at the bone-implant interface regulates structural stability of an implant. In this work, we seek to understand how the 3D mechanical environment of an implant affects bone formation during early osteointegration. We employed two-photon lithography (TPL) direct laser writing to fabricate 3-dimensional rigid polymer scaffolds with tetrakaidecahedral periodic geometry, herewith referred to as nanolattices, whose strut dimensions were on the same order as osteoblasts' focal adhesions (∼2μm) and pore sizes on the order of cell size, ∼10μm. Some of these nanolattices were subsequently coated with thin conformal layers of Ti or W, and a final outer layer of 18nm-thick TiO2 was deposited on all samples to ensure biocompatibility. Nanomechanical experiments on each type of nanolattice revealed the range of stiffnesses of 0.7-100MPa. Osteoblast-like cells (SAOS-2) were seeded on each nanolattice, and their mechanosensitve response was explored by tracking mineral secretions and intracellular f-actin and vinculin concentrations after 2, 8 and 12days of cell culture in mineralization media. Experiments revealed that the most compliant nanolattices had ∼20% more intracellular f-actin and ∼40% more Ca and P secreted onto them than the stiffer nanolattices, where such cellular response was virtually indistinguishable. We constructed a simple phenomenological model that appears to capture the observed relation between scaffold stiffness and f-actin concentration. This model predicts a range of optimal scaffold stiffnesses for maximum f-actin concentration, which appears to be directly correlated with osteoblast-driven mineral deposition. This work suggests that three-dimensional scaffolds with titania-coated surfaces may provide an optimal microenvironment for cell growth when their stiffness is similar to that of cartilage (∼0.5-3MPa). These findings help provide a greater understanding of osteoblast mechanosensitivity and may have profound implications in developing more effective and safer bone prostheses. STATEMENT OF SIGNIFICANCE Creating prostheses that lead to optimal bone remodeling has been a challenge for more than two decades because of a lack of thorough knowledge of cell behavior in three-dimensional (3D) environments. Literature has shown that 2D substrate stiffness plays a significant role in determining cell behavior, however, limitations in fabrication techniques and difficulties in characterizing cell-scaffold interactions have limited our understanding of how 3D scaffolds' stiffness affects cell response. The present study shows that scaffold structural stiffness affects osteoblasts cellular response. Specifically this work shows that the cells grown on the most compliant nanolattices with a stiffness of 0.7MPa expressed ∼20% higher concentration of intracellular f-actin and secreted ∼40% more Ca and P compared with all other nanolattices. This suggests that bone scaffolds with a stiffness close to that of cartilage may serve as optimal 3D scaffolds for new synthetic bone graft materials.
Collapse
|
47
|
Melancon D, Bagheri ZS, Johnston RB, Liu L, Tanzer M, Pasini D. Mechanical characterization of structurally porous biomaterials built via additive manufacturing: experiments, predictive models, and design maps for load-bearing bone replacement implants. Acta Biomater 2017; 63:350-368. [PMID: 28927929 DOI: 10.1016/j.actbio.2017.09.013] [Citation(s) in RCA: 64] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2017] [Revised: 08/30/2017] [Accepted: 09/12/2017] [Indexed: 11/18/2022]
Abstract
Porous biomaterials can be additively manufactured with micro-architecture tailored to satisfy the stringent mechano-biological requirements imposed by bone replacement implants. In a previous investigation, we introduced structurally porous biomaterials, featuring strength five times stronger than commercially available porous materials, and confirmed their bone ingrowth capability in an in vivo canine model. While encouraging, the manufactured biomaterials showed geometric mismatches between their internal porous architecture and that of its as-designed counterpart, as well as discrepancies between predicted and tested mechanical properties, issues not fully elucidated. In this work, we propose a systematic approach integrating computed tomography, mechanical testing, and statistical analysis of geometric imperfections to generate statistical based numerical models of high-strength additively manufactured porous biomaterials. The method is used to develop morphology and mechanical maps that illustrate the role played by pore size, porosity, strut thickness, and topology on the relations governing their elastic modulus and compressive yield strength. Overall, there are mismatches between the mechanical properties of ideal-geometry models and as-manufactured porous biomaterials with average errors of 49% and 41% respectively for compressive elastic modulus and yield strength. The proposed methodology gives more accurate predictions for the compressive stiffness and the compressive strength properties with a reduction of the average error to 11% and 7.6%. The implications of the results and the methodology here introduced are discussed in the relevant biomechanical and clinical context, with insight that highlights promises and limitations of additively manufactured porous biomaterials for load-bearing bone replacement implants. STATEMENT OF SIGNIFICANCE In this work, we perform mechanical characterization of load-bearing porous biomaterials for bone replacement over their entire design space. Results capture the shift in geometry and mechanical properties between as-designed and as-manufactured biomaterials induced by additive manufacturing. Characterization of this shift is crucial to ensure appropriate manufacturing of bone replacement implants that enable biological fixation through bone ingrowth as well as mechanical property harmonization with the native bone tissue. In addition, we propose a method to include manufacturing imperfections in the numerical models that can reduce the discrepancy between predicted and tested properties. The results give insight into the use of structurally porous biomaterials for the design and additive fabrication of load-bearing implants for bone replacement.
Collapse
Affiliation(s)
- D Melancon
- Mechanical Engineering Department, McGill University, Montreal, Quebec H3G 1A4, Canada
| | - Z S Bagheri
- Mechanical Engineering Department, McGill University, Montreal, Quebec H3G 1A4, Canada
| | - R B Johnston
- Mechanical Engineering Department, McGill University, Montreal, Quebec H3G 1A4, Canada
| | - L Liu
- Mechanical Engineering Department, McGill University, Montreal, Quebec H3G 1A4, Canada
| | - M Tanzer
- Division of Orthopaedics, Department of Surgery, McGill University, Montreal, Quebec H3G 1A4, Canada
| | - D Pasini
- Mechanical Engineering Department, McGill University, Montreal, Quebec H3G 1A4, Canada.
| |
Collapse
|
48
|
Oomen PJA, van Kelle MAJ, Oomens CWJ, Bouten CVC, Loerakker S. Nondestructive mechanical characterization of developing biological tissues using inflation testing. J Mech Behav Biomed Mater 2017; 74:438-447. [PMID: 28709754 DOI: 10.1016/j.jmbbm.2017.07.009] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2017] [Revised: 06/25/2017] [Accepted: 07/04/2017] [Indexed: 11/17/2022]
Abstract
One of the hallmarks of biological soft tissues is their capacity to grow and remodel in response to changes in their environment. Although it is well-accepted that these processes occur at least partly to maintain a mechanical homeostasis, it remains unclear which mechanical constituent(s) determine(s) mechanical homeostasis. In the current study a nondestructive mechanical test and a two-step inverse analysis method were developed and validated to nondestructively estimate the mechanical properties of biological tissue during tissue culture. Nondestructive mechanical testing was achieved by performing an inflation test on tissues that were cultured inside a bioreactor, while the tissue displacement and thickness were nondestructively measured using ultrasound. The material parameters were estimated by an inverse finite element scheme, which was preceded by an analytical estimation step to rapidly obtain an initial estimate that already approximated the final solution. The efficiency and accuracy of the two-step inverse method was demonstrated on virtual experiments of several material types with known parameters. PDMS samples were used to demonstrate the method's feasibility, where it was shown that the proposed method yielded similar results to tensile testing. Finally, the method was applied to estimate the material properties of tissue-engineered constructs. Via this method, the evolution of mechanical properties during tissue growth and remodeling can now be monitored in a well-controlled system. The outcomes can be used to determine various mechanical constituents and to assess their contribution to mechanical homeostasis.
Collapse
Affiliation(s)
- P J A Oomen
- Department of Biomedical Engineering, Eindhoven University of Technology, 5600MB Eindhoven, Netherlands; Institute for Complex Molecular Systems, Eindhoven University of Technology, 5600MB Eindhoven, Netherlands.
| | - M A J van Kelle
- Department of Biomedical Engineering, Eindhoven University of Technology, 5600MB Eindhoven, Netherlands; Institute for Complex Molecular Systems, Eindhoven University of Technology, 5600MB Eindhoven, Netherlands
| | - C W J Oomens
- Department of Biomedical Engineering, Eindhoven University of Technology, 5600MB Eindhoven, Netherlands
| | - C V C Bouten
- Department of Biomedical Engineering, Eindhoven University of Technology, 5600MB Eindhoven, Netherlands; Institute for Complex Molecular Systems, Eindhoven University of Technology, 5600MB Eindhoven, Netherlands
| | - S Loerakker
- Department of Biomedical Engineering, Eindhoven University of Technology, 5600MB Eindhoven, Netherlands; Institute for Complex Molecular Systems, Eindhoven University of Technology, 5600MB Eindhoven, Netherlands.
| |
Collapse
|
49
|
Masri C, Chagnon G, Favier D. Influence of processing parameters on the macroscopic mechanical behavior of PVA hydrogels. Mater Sci Eng C Mater Biol Appl 2017; 75:769-76. [PMID: 28415527 DOI: 10.1016/j.msec.2017.02.045] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/29/2016] [Revised: 12/04/2016] [Accepted: 02/10/2017] [Indexed: 11/23/2022]
Abstract
This paper investigates the influence of three different processing parameters on the global mechanical behavior of PVA (Polyvinyl alcohol)/DMSO (Dimethylsulfoxide) hydrogels: the initial concentration of PVA, the DMSO:H2O ratio and the number of freeze/thaw cycle applied to the material. A specific thermo-regulated testing apparatus for hydrophilic materials is presented, along with the performed cyclic and rupture tests. The observed mechanical responses are explained by an in-depth analysis of the cross-linking phenomenon. Using the Neo-Hookean hyperelastic model, the experimental data is fitted and a link between the density of macro-molecular chains in the material and its mechanical behavior is established. Strong differences are observed and discussed.
Collapse
|
50
|
De Leon-Rodriguez LM, Hemar Y, Mo G, Mitra AK, Cornish J, Brimble MA. Multifunctional thermoresponsive designer peptide hydrogels. Acta Biomater 2017; 47:40-49. [PMID: 27744067 DOI: 10.1016/j.actbio.2016.10.014] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2016] [Revised: 10/10/2016] [Accepted: 10/10/2016] [Indexed: 02/07/2023]
Abstract
We report the synthesis and characterization of multifunctional peptides comprised of a hydrogel forming β-sheet peptide segment and a matrix metalloproteinase 2 substrate containing a propargylglycinyl linker that is further derivatized with an RGD peptide sequence via "click" chemistry. In contrast to currently known systems, these multifunctional peptides formed gels that are stiffer than those formed by their respective precursors. All the peptides showed reversible thermoresponsive properties, which render them as suitable lead systems for a variety of possible biomedical applications. STATEMENT OF SIGNIFICANCE In general, it has been frequently observed that chemical biofunctionalization of peptide hydrogels adversely affects peptide assembly, hydrogel formation or mechanical properties, which severely compromises their application. A functionalization protocol that allows to generate peptide hydrogels that display significantly improved mechanical properties over their unfunctionalized counterparts is reported in this work. These peptides also showed thermoresponsive viscoelastic characteristics, including an example of a peptide hydrogel that displays lower critical solution temperature behaviour.
Collapse
Affiliation(s)
- Luis M De Leon-Rodriguez
- School of Biological Sciences, The University of Auckland, 3A Symonds St, Thomas Building, Auckland 1010, New Zealand.
| | - Yacine Hemar
- School of Chemical Sciences, The University of Auckland, 23 Symonds St, Auckland 1010, New Zealand
| | - Guang Mo
- Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing, China
| | - Alok K Mitra
- School of Biological Sciences, The University of Auckland, 3A Symonds St, Thomas Building, Auckland 1010, New Zealand
| | - Jillian Cornish
- Department of Medicine, The University of Auckland, Auckland, New Zealand
| | - Margaret A Brimble
- School of Biological Sciences, The University of Auckland, 3A Symonds St, Thomas Building, Auckland 1010, New Zealand; School of Chemical Sciences, The University of Auckland, 23 Symonds St, Auckland 1010, New Zealand.
| |
Collapse
|