1
|
Lin X, Wu H, Zeng S, Peng T, Zhang P, Wan X, Lang Y, Zhang B, Jia Y, Shen R, Yin B. A self-designed device integrated with a Fermat spiral microfluidic chip for ratiometric and automated point-of-care testing of anthrax biomarker in real samples. Biosens Bioelectron 2023; 230:115283. [PMID: 37019031 DOI: 10.1016/j.bios.2023.115283] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Revised: 03/12/2023] [Accepted: 03/28/2023] [Indexed: 04/03/2023]
Abstract
A desirable lanthanide-based ratiometric fluorescent probe was designed and integrated into a self-designed Fermat spiral microfluidic chip (FS-MC) for the automated determination of a unique bacterial endospore biomarker, dipicolinic acid (DPA), with high selectivity and sensitivity. Here, a blue emission wavelength at 425 nm was generated in the Fermat spiral structure by mixing the europium (Eu3+) and luminol to form the Eu3+/Luminol sensing probe. DPA in the reservoir can be used to specifically bind to Eu3+ under the negative pressure and transfer energy from DPA to Eu3+ sequentially via an antenna effect, thus resulting in a significant increase in the red fluorescence emission peak at 615 nm. According to the fluorescence intensity ratio (F615/F425), a good linearity can be obtained with increasing the concentration of DPA from 0 to 200 μM with a limit of detection as low as 10.11 nM. Interestingly, the designed FS-MC can achieve rapid detection of DPA in only 1 min, reducing detection time and improving sensitivity. Furthermore, a self-designed device integrated with the FS-MC and a smartphone color picker APP was employed for the rapid automatic point-of-care testing (POCT) of DPA in the field, simplifying complex processes and reducing testing times, thus confirming the great promise of this ready-to-use measurement platform for in situ inspection.
Collapse
|
2
|
Xie Y, Dai L, Yang Y. Microfluidic technology and its application in the point-of-care testing field. BIOSENSORS & BIOELECTRONICS: X 2022; 10:100109. [PMID: 35075447 PMCID: PMC8769924 DOI: 10.1016/j.biosx.2022.100109] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/19/2021] [Revised: 01/06/2022] [Accepted: 01/09/2022] [Indexed: 05/15/2023]
Abstract
Since the outbreak of the coronavirus disease 2019 (COVID-19), countries around the world have suffered heavy losses of life and property. The global pandemic poses a challenge to the global public health system, and public health organizations around the world are actively looking for ways to quickly and efficiently screen for viruses. Point-of-care testing (POCT), as a fast, portable, and instant detection method, is of great significance in infectious disease detection, disease screening, pre-disease prevention, postoperative treatment, and other fields. Microfluidic technology is a comprehensive technology that involves various interdisciplinary disciplines. It is also known as a lab-on-a-chip (LOC), and can concentrate biological and chemical experiments in traditional laboratories on a chip of several square centimeters with high integration. Therefore, microfluidic devices have become the primary implementation platform of POCT technology. POCT devices based on microfluidic technology combine the advantages of both POCT and microfluids, and are expected to shine in the biomedical field. This review introduces microfluidic technology and its applications in combination with other technologies.
Collapse
Affiliation(s)
- Yaping Xie
- Sansure Biotech Inc., Changsha, 410205, PR China
- School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, 430074, PR China
| | - Lizhong Dai
- Sansure Biotech Inc., Changsha, 410205, PR China
| | - Yijia Yang
- Sansure Biotech Inc., Changsha, 410205, PR China
| |
Collapse
|
3
|
A Review of Apta-POF-Sensors: The Successful Coupling between Aptamers and Plastic Optical Fibers for Biosensing Applications. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12094584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Aptamers represent the next frontier as biorecognition elements in biosensors thanks to a smaller size and lower molecular weight with respect to antibodies, more structural flexibility with the possibility to be regenerated, reduced batch-to-batch variation, and a potentially lower cost. Their high specificity and small size are particularly interesting for their application in optical biosensors since the perturbation of the evanescent field are low. Apart from the conventional plasmonic optical sensors, platforms based on silica and plastic optical fibers represent an interesting class of devices for point-of-care testing (POCT) in different applications. The first example of the coupling between aptamers and silica optical fibers was reported by Pollet in 2009 for the detection of IgE molecules. Six years later, the first example was published using a plastic optical fiber (POF) for the detection of Vascular Endothelial Growth Factor (VEGF). The excellent flexibility, great numerical aperture, and the large diameter make POFs extremely promising to be coupled to aptamers for the development of a sensitive platform easily integrable in portable, small-size, and simple devices. Starting from silica fiber-based surface plasmon resonance devices, here, a focus on significant biological applications based on aptamers, combined with plasmonic-POF probes, is reported.
Collapse
|
4
|
Serological and molecular rapid diagnostic tests for Toxoplasma infection in humans and animals. Eur J Clin Microbiol Infect Dis 2019; 39:19-30. [PMID: 31428897 PMCID: PMC7087738 DOI: 10.1007/s10096-019-03680-2] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2019] [Accepted: 08/11/2019] [Indexed: 02/07/2023]
Abstract
Infection by Toxoplasma gondii is prevalent worldwide. The parasite can infect a broad spectrum of vertebrate hosts, but infection of fetuses and immunocompromised patients is of particular concern. Easy-to-perform, robust, and highly sensitive and specific methods to detect Toxoplasma infection are important for the treatment and management of patients. Rapid diagnostic methods that do not sacrifice the accuracy of the assay and give reproducible results in a short time are highly desirable. In this context, rapid diagnostic tests (RDTs), especially with point-of-care (POC) features, are promising diagnostic methods in clinical microbiology laboratories, especially in areas with minimal laboratory facilities. More advanced methods using microfluidics and sensor technology will be the future trend. In this review, we discuss serological and molecular-based rapid diagnostic tests for detecting Toxoplasma infection in humans as well as animals.
Collapse
|
5
|
Abbasian F, Ghafar-Zadeh E, Magierowski S. Microbiological Sensing Technologies: A Review. Bioengineering (Basel) 2018; 5:E20. [PMID: 29498670 PMCID: PMC5874886 DOI: 10.3390/bioengineering5010020] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2017] [Revised: 02/23/2018] [Accepted: 02/23/2018] [Indexed: 12/13/2022] Open
Abstract
Microorganisms have a significant influence on human activities and health, and consequently, there is high demand to develop automated, sensitive, and rapid methods for their detection. These methods might be applicable for clinical, industrial, and environmental applications. Although different techniques have been suggested and employed for the detection of microorganisms, and the majority of these methods are not cost effective and suffer from low sensitivity and low specificity, especially in mixed samples. This paper presents a comprehensive review of microbiological techniques and associated challenges for bioengineering researchers with an engineering background. Also, this paper reports on recent technological advances and their future prospects for a variety of microbiological applications.
Collapse
Affiliation(s)
- Firouz Abbasian
- Biologically Inspired Sensors and Actuators Laboratory, Department of EECS, Lassonde School of Engineering, York University, Toronto, ON M3J 1P3, Canada.
| | - Ebrahim Ghafar-Zadeh
- Biologically Inspired Sensors and Actuators Laboratory, Department of EECS, Lassonde School of Engineering, York University, Toronto, ON M3J 1P3, Canada.
| | - Sebastian Magierowski
- Biologically Inspired Sensors and Actuators Laboratory, Department of EECS, Lassonde School of Engineering, York University, Toronto, ON M3J 1P3, Canada.
| |
Collapse
|
6
|
Coffel J, Nuxoll E. BioMEMS for biosensors and closed-loop drug delivery. Int J Pharm 2018; 544:335-349. [PMID: 29378239 DOI: 10.1016/j.ijpharm.2018.01.030] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2017] [Revised: 01/10/2018] [Accepted: 01/14/2018] [Indexed: 12/14/2022]
Abstract
The efficacy of pharmaceutical treatments can be greatly enhanced by physiological feedback from the patient using biosensors, though this is often invasive or infeasible. By adapting microelectromechanical systems (MEMS) technology to miniaturize such biosensors, previously inaccessible signals can be obtained, often from inside the patient. This is enabled by the device's extremely small footprint which minimizes both power consumption and implantation trauma, as well as the transport time for chemical analytes, in turn decreasing the sensor's response time. MEMS fabrication also allows mass production which can be easily scaled without sacrificing its high reproducibility and reliability, and allows seamless integration with control circuitry and telemetry which is already produced using the same materials and fabrication steps. By integrating these systems with drug delivery devices, many of which are also MEMS-based, closed loop drug delivery can be achieved. This paper surveys the types of signal transduction devices available for biosensing-primarily electrochemical, optical, and mechanical-looking at their implementation via MEMS technology. The impact of MEMS technology on the challenges of biosensor development, particularly safety, power consumption, degradation, fouling, and foreign body response, are also discussed.
Collapse
Affiliation(s)
- Joel Coffel
- Department of Chemical and Biochemical Engineering, 4133 Seamans Center for the Engineering Arts & Sciences, University of Iowa, Iowa City, IA 52242, USA
| | - Eric Nuxoll
- Department of Chemical and Biochemical Engineering, 4133 Seamans Center for the Engineering Arts & Sciences, University of Iowa, Iowa City, IA 52242, USA.
| |
Collapse
|
7
|
Peng G, He Q, Lu Y, Huang J, Lin JM. Flow injection microfluidic device with on-line fluorescent derivatization for the determination of Cr(III) and Cr(VI) in water samples after solid phase extraction. Anal Chim Acta 2017; 955:58-66. [DOI: 10.1016/j.aca.2016.11.057] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2016] [Revised: 11/14/2016] [Accepted: 11/28/2016] [Indexed: 12/01/2022]
|
8
|
Ngernsutivorakul T, Cipolla CM, Dugan CE, Jin S, Morris MD, Kennedy RT, Esmonde-White FWL. Design and microfabrication of a miniature fiber optic probe with integrated lenses and mirrors for Raman and fluorescence measurements. Anal Bioanal Chem 2017; 409:275-285. [PMID: 27766359 PMCID: PMC5203949 DOI: 10.1007/s00216-016-9999-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2016] [Revised: 09/19/2016] [Accepted: 09/30/2016] [Indexed: 12/22/2022]
Abstract
Fiber optics coupled to components such as lenses and mirrors have seen extensive use as probes for Raman and fluorescence measurements. Probes can be placed directly on or into a sample to allow for simplified and remote application of these optical techniques. The size and complexity of such probes however limits their application. We have used microfabrication in polydimethylsiloxane (PDMS) to create compact probes that are 0.5 mm thick by 1 mm wide. The miniature probes incorporate pre-aligned mirrors, lenses, and two fiber optic guides to allow separate input and output optical paths suitable for Raman and fluorescence spectroscopy measurements. The fabricated probe has 70 % unidirectional optical throughput and generates no spectral artifacts in the wavelength range of 200 to 800 nm. The probe is demonstrated for measurement of fluorescence within microfluidic devices and collection of Raman spectra from a pharmaceutical tablet. The fluorescence limit of detection was 6 nM when using the probe to measure resorufin inside a 150-μm inner diameter glass capillary, 100 nM for resorufin in a 60-μm-deep × 100-μm-wide PDMS channel, and 11 nM for fluorescein in a 25-μm-deep × 80-μm-wide glass channel. It is demonstrated that the same probe can be used on different sample types, e.g., microfluidic chips and tablets. Compared to existing Raman and fluorescence probes, the microfabricated probes enable measurement in smaller spaces and have lower fabrication cost. Graphical abstract A microfabricated spectroscopic probe with integrated optics was developed for chemical detection in small spaces and in remote applications.
Collapse
Affiliation(s)
| | - Cynthia M Cipolla
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI, 48109, USA
| | - Colleen E Dugan
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI, 48109, USA
| | - Shi Jin
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI, 48109, USA
| | - Michael D Morris
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI, 48109, USA
| | - Robert T Kennedy
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI, 48109, USA.
- Department of Pharmacology, University of Michigan, 1150 W. Medical Center Drive, Ann Arbor, MI, 48109, USA.
| | - Francis W L Esmonde-White
- Department of Chemistry, University of Michigan, 930 N. University Ave, Ann Arbor, MI, 48109, USA
- Kaiser Optical Systems Inc, 371 Parkland Plaza, Ann Arbor, MI, 48103, USA
| |
Collapse
|
9
|
Ma Y, Mao Y, Huang D, He Z, Yan J, Tian T, Shi Y, Song Y, Li X, Zhu Z, Zhou L, Yang CJ. Portable visual quantitative detection of aflatoxin B1 using a target-responsive hydrogel and a distance-readout microfluidic chip. LAB ON A CHIP 2016; 16:3097-104. [PMID: 27302553 DOI: 10.1039/c6lc00474a] [Citation(s) in RCA: 85] [Impact Index Per Article: 10.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Aflatoxin B1 (AFB1), as the secondary metabolite of molds, is the most predominant and toxic mycotoxin that seriously threatens the health of humans and animals. In this work, an AFB1-responsive hydrogel was synthesized for highly sensitive and portable detection of AFB1. The AFB1-responsive hydrogel was prepared using an AFB1 aptamer and its two short complementary DNA strands as cross-linkers. For visual detection of AFB1, the hydrogel is preloaded with gold nanoparticles (AuNPs). Upon introduction of AFB1, the AFB1 aptamer binds with AFB1, leading to the disruption of the hydrogel and release of the AuNPs with a distinct color change of the supernatant from colorless to red. In order to lower the detection limit and extend the method to quantitative analysis, a distance-readout volumetric bar chart chip (V-chip) was combined with an AFB1-responsive hydrogel preloaded with platinum nanoparticles (PtNPs). In the presence of AFB1, the hydrogel collapses and releases PtNPs which can catalyze the decomposition of H2O2 to generate O2. The increasing gas pressure moves a red ink bar in the V-chip and provides a quantitative relationship between the distance and the concentration of AFB1. The method was applied for detection of AFB1 in beer, with a detection limit of 1.77 nM (0.55 ppb) where an immunoaffinity column (IAC) of AFB1 was used to cleanup and pre-concentrate the sample, which satisfies the testing requirement of 2.0 ppb set by the European Union. The combination of an AFB1-responsive hydrogel with a distance-based readout V-chip offers a user-friendly POCT device, which has great potential for rapid, portable, selective, and quantitative detection of AFB1 in real samples to ensure food safety and avoid subsequent economic losses.
Collapse
Affiliation(s)
- Yanli Ma
- MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Yu Mao
- MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Di Huang
- MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Zhe He
- MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Jinmao Yan
- MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Tian Tian
- MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Yuanzhi Shi
- MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Yanling Song
- MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Xingrui Li
- MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Zhi Zhu
- MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Leiji Zhou
- MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| | - Chaoyong James Yang
- MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, Collaborative Innovation Center of Chemistry for Energy Materials, Key Laboratory for Chemical Biology of Fujian Province, State Key Laboratory of Physical Chemistry of Solid Surfaces, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.
| |
Collapse
|
10
|
Mohammed M, Desmulliez M. Autonomous capillary microfluidic system with embedded optics for improved troponin I cardiac biomarker detection. Biosens Bioelectron 2014; 61:478-84. [DOI: 10.1016/j.bios.2014.05.042] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2014] [Revised: 04/29/2014] [Accepted: 05/18/2014] [Indexed: 11/24/2022]
|
11
|
Integration of Organic Light Emitting Diodes and Organic Photodetectors for Lab-on-a-Chip Bio-Detection Systems. ELECTRONICS 2014. [DOI: 10.3390/electronics3010043] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
12
|
Wongkaew N, He P, Kurth V, Surareungchai W, Baeumner AJ. Multi-channel PMMA microfluidic biosensor with integrated IDUAs for electrochemical detection. Anal Bioanal Chem 2013; 405:5965-74. [PMID: 23681202 PMCID: PMC3770862 DOI: 10.1007/s00216-013-7020-0] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2013] [Revised: 04/12/2013] [Accepted: 04/24/2013] [Indexed: 10/26/2022]
Abstract
A novel multi-channel poly(methyl methacrylate) (PMMA) microfluidic biosensor with interdigitated ultramicroelectrode arrays (IDUAs) for electrochemical detection was developed. The focus of the development was a simple fabrication procedure and the realization of a reliable large IDUA that can provide detection simultaneously to several microchannels. As proof of concept, five microchannels are positioned over a large single IDUA where the channels are parallel with the length of the electrode finger. The IDUAs were fabricated on the PMMA cover piece and bonded to a PMMA substrate containing the microfluidic channels using UV/ozone-assisted thermal bonding. Conditions of device fabrication were optimized realizing a rugged large IDUA within a bonded PMMA device. Gold adhesion to the PMMA, protective coatings, and pressure during bonding were optimized. Its electrochemical performance was studied using amperometric detection of potassium ferri and ferro hexacyanide. Cumulative signals within the same chip showed very good linearity over a range of 0-38 μM (R(2) = 0.98) and a limit of detection of 3.48 μM. The bonding of the device was optimized so that no cross talk between the channels was observed which otherwise would have resulted in unreliable electrochemical responses. The highly reproducible signals achieved were comparable to those obtained with separate single-channel devices. Subsequently, the multi-channel microfluidic chip was applied to a model bioanalytical detection strategy, i.e., the quantification of specific nucleic acid sequences using a sandwich approach. Here, probe-coated paramagnetic beads and probe-tagged liposomes entrapping ferri/ferro hexacyanide as the redox marker were used to bind to a single-stranded DNA sequence. Flow rates of the non-ionic detergent n-octyl-β-D-glucopyranoside for liposome lysis were optimized, and the detection of the target sequences was carried out coulometrically within 250 s and with a limit of detection of 12.5 μM. The robustness of the design and the reliability of the results obtained in comparison to previously published single-channel designs suggest that the multi-channel device offers an excellent opportunity for bioanalytical applications that require multianalyte detection and high-throughput assays.
Collapse
Affiliation(s)
- Nongnoot Wongkaew
- School of Bioresources and Technology, King Mongkut's University of Technology Thonburi, Bangkhuntien, Bangkok 10150,Thailand
- Department of Biological and Environmental Engineering, Cornell University, 202 Riley Robb Hall, Ithaca, NY 14853, USA
| | - Peng He
- Department of Biological and Environmental Engineering, Cornell University, 202 Riley Robb Hall, Ithaca, NY 14853, USA
| | - Vanessa Kurth
- Department of Biological and Environmental Engineering, Cornell University, 202 Riley Robb Hall, Ithaca, NY 14853, USA
| | - Werasak Surareungchai
- School of Bioresources and Technology, King Mongkut's University of Technology Thonburi, Bangkhuntien, Bangkok 10150,Thailand
| | - Antje J. Baeumner
- Department of Biological and Environmental Engineering, Cornell University, 202 Riley Robb Hall, Ithaca, NY 14853, USA
| |
Collapse
|
13
|
Mohammed MI, Desmulliez MPY. Planar lens integrated capillary action microfluidic immunoassay device for the optical detection of troponin I. BIOMICROFLUIDICS 2013; 7:64112. [PMID: 24396546 PMCID: PMC3869829 DOI: 10.1063/1.4837755] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/09/2013] [Accepted: 11/19/2013] [Indexed: 05/21/2023]
Abstract
Optical based analysis in microfluidic and lab-on-a-chip systems are currently considered the gold standard methodology for the determination of end point reactions for various chemical and biological reaction processes. Typically, assays are performed using bulky ancillary apparatus such as microscopes and complex optical excitation and detection systems. Such instrumentation negates many of the advantages offered by device miniaturisation, particularly with respect to overall portability. In this article, we present a CO2 laser ablation technique for rapidly prototyping on-chip planar lenses, in conjunction with capillary action based autonomous microfluidics, to create a miniaturised and fully integrated optical biosensing platform. The presented self-aligned on-chip optical components offer an efficient means to direct excitation light within microfluidics and to directly couple light from a LED source. The device has been used in conjunction with a miniaturised and bespoke fluorescence detection platform to create a complete, palm sized system (≈60 × 80 × 60 mm) capable of performing fluoro-immunoassays. The system has been applied to the detection of cardiac Troponin I, one of the gold standard biomarkers for the diagnosis of acute myocardial infarction, achieving a lower detection limit of 0.08 ng/ml, which is at the threshold of clinically applicable concentrations. The portable nature of the complete system and the biomarker detection capabilities demonstrate the potential of the devised instrumentation for use as a medical diagnostics device at the point of care.
Collapse
Affiliation(s)
- Mazher-Iqbal Mohammed
- Heriot-Watt University, MicroSystems Engineering Centre (MISEC), School of Engineering & Physical Sciences, Earl Mountbatten Building, Edinburgh EH14 4AS, Scotland
| | - Marc P Y Desmulliez
- Heriot-Watt University, MicroSystems Engineering Centre (MISEC), School of Engineering & Physical Sciences, Earl Mountbatten Building, Edinburgh EH14 4AS, Scotland
| |
Collapse
|
14
|
Yamazaki M, Krishnadasan S, deMello AJ, deMello JC. Non-emissive plastic colour filters for fluorescence detection. LAB ON A CHIP 2012; 12:4313-4320. [PMID: 22971690 DOI: 10.1039/c2lc40718c] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
We report the fabrication of non-emissive short- and long-pass filters on plastic for high sensitivity fluorescence detection. The filters were prepared by overnight immersion of titania-coated polyethylene terephthalate (PET) in an appropriate dye solution - xylene cyanol for short-pass filtering and fluorescein disodium salt for long-pass filtering - followed by repeated washing to remove excess dye. The interface between the titania and the dye molecule induces efficient quenching of photo-generated excitons in the dye molecule, reducing auto-fluorescence to negligible values and so overcoming the principal weakness of conventional colour filters. Using the filters in conjunction with a 505 nm cyan light-emitting diode and a Si photodiode, dose-response measurements were made for T8661 Transfluosphere beads in the concentration range 1 × 10(9) to 1 × 10(5) beads μL(-1), yielding a limit of detection of 3 × 10(4) beads μL(-1). The LED/short-pass filter/T8661/long-pass filter/Si-photodiode combination reported here offers an attractive solution for sensitive, low cost fluorescence detection that is readily applicable to a wide range of bead-based immunodiagnostic assays.
Collapse
Affiliation(s)
- M Yamazaki
- Dept. Chemistry and Centre for Plastic Electronics, Imperial College London, Exhibition Road South Kensington, London SW7 2AY, UK
| | | | | | | |
Collapse
|
15
|
Yamazaki M, Hofmann O, Ryu G, Xiaoe L, Lee TK, deMello AJ, deMello JC. Non-emissive colour filters for fluorescence detection. LAB ON A CHIP 2011; 11:1228-1233. [PMID: 21350748 DOI: 10.1039/c0lc00642d] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
We describe a simple technique for fabricating non-emissive colour filters based on the sensitisation of a highly porous nanostructured metal-oxide film with a monolayer of dye molecules. Ultrafast electron transfer at the oxide/dye interface induces efficient quenching of photogenerated excitons in the dye, reducing the photoluminescence quantum yield by many orders of magnitude. The resultant filters exhibit much less autofluorescence than conventional colour filters (where the chromophore is dispersed in a glass or polymer host), and are a viable low cost alternative to interference filters for microfluidic devices and other applications requiring non-emissive filtering.
Collapse
Affiliation(s)
- Mikihide Yamazaki
- Department of Chemistry, Imperial College London, South Kensington, London, United Kingdom
| | | | | | | | | | | | | |
Collapse
|
16
|
Rivet C, Lee H, Hirsch A, Hamilton S, Lu H. Microfluidics for medical diagnostics and biosensors. Chem Eng Sci 2011. [DOI: 10.1016/j.ces.2010.08.015] [Citation(s) in RCA: 140] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
|
17
|
Oita I, Halewyck H, Thys B, Rombaut B, Vander Heyden Y, Mangelings D. Microfluidics in macro-biomolecules analysis: macro inside in a nano world. Anal Bioanal Chem 2010; 398:239-64. [PMID: 20549494 PMCID: PMC7079953 DOI: 10.1007/s00216-010-3857-7] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2010] [Revised: 05/13/2010] [Accepted: 05/18/2010] [Indexed: 12/26/2022]
Abstract
Use of microfluidic devices in the life sciences and medicine has created the possibility of performing investigations at the molecular level. Moreover, microfluidic devices are also part of the technological framework that has enabled a new type of scientific information to be revealed, i.e. that based on intensive screening of complete sets of gene and protein sequences. A deeper bioanalytical perspective may provide quantitative and qualitative tools, enabling study of various diseases and, eventually, may offer support for the development of accurate and reliable methods for clinical assessment. This would open the way to molecule-based diagnostics, i.e. establish accurate diagnosis and disease prognosis based on identification and/or quantification of biomacromolecules, for example proteins or nucleic acids. Finally, the development of disposable and portable devices for molecule-based diagnosis would provide the perfect translation of the science behind life-science research into practical applications dedicated to patients and health practitioners. This review provides an analytical perspective of the impact of microfluidics on the detection and characterization of bio-macromolecules involved in pathological processes. The main features of molecule-based diagnostics and the specific requirements for the diagnostic devices are discussed. Further, the techniques currently used for testing bio-macromolecules for potential diagnostic purposes are identified, emphasizing the newest developments. Subsequently, the challenges of this type of application and the status of commercially available devices are highlighted, and future trends are noted.
Collapse
Affiliation(s)
- Iuliana Oita
- Department of Analytical Chemistry and Pharmaceutical Technology, Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, Brussels, 1090 Belgium
| | - Hadewych Halewyck
- Department of Pharmaceutical Biotechnology & Molecular Biology, Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, Brussels, 1090 Belgium
| | - Bert Thys
- Department of Pharmaceutical Biotechnology & Molecular Biology, Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, Brussels, 1090 Belgium
| | - Bart Rombaut
- Department of Pharmaceutical Biotechnology & Molecular Biology, Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, Brussels, 1090 Belgium
| | - Yvan Vander Heyden
- Department of Analytical Chemistry and Pharmaceutical Technology, Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, Brussels, 1090 Belgium
| | - Debby Mangelings
- Department of Analytical Chemistry and Pharmaceutical Technology, Center for Pharmaceutical Research (CePhaR), Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, Brussels, 1090 Belgium
| |
Collapse
|
18
|
Minas G, Wolffenbuttel RF, Correia JH. MCM-based microlaboratory for simultaneous measurement of several biochemical parameters by spectrophotometry. Biomed Microdevices 2010; 12:727-36. [DOI: 10.1007/s10544-010-9426-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
19
|
Luo L, Hou W, Yu J. Novel Real-Time Fluorescent PCR Chip Applied to Examine the Ankylosing Spondylitis. ANAL LETT 2010. [DOI: 10.1080/00032710802677167] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
20
|
Schulze H, Giraud G, Crain J, Bachmann TT. Multiplexed optical pathogen detection with lab-on-a-chip devices. JOURNAL OF BIOPHOTONICS 2009; 2:199-211. [PMID: 19367588 DOI: 10.1002/jbio.200910009] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
Infectious diseases are still a main cause of human morbidity and mortality. Advanced diagnostics is considered to be a key driver to improve the respective therapeutic outcome. The main factors influencing the impact of diagnostics include: assay speed, availability, information content, in-vitro diagnostics and cost, for which molecular assays are providing the most promising opportunities. Miniaturisation and integration of assay steps into lab-on-a-chip devices has been described as an appropriate way to speed up assay time and make assays available onsite at competitive costs. As meaningful assays for infectious diseases need to include a whole range of clinical relevant information about the pathogen, multiplexed functionality is often required for which optical transduction is particularly well suited. The aim of this review is to assess existing developments in this field and to give an outlook on future requirements and solutions.
Collapse
Affiliation(s)
- Holger Schulze
- Division of Pathway Medicine, Medical School, The University of Edinburgh, Edinburgh, Scotland UK
| | | | | | | |
Collapse
|
21
|
Darain F, Yager P, Gan KL, Tjin SC. On-chip detection of myoglobin based on fluorescence. Biosens Bioelectron 2009; 24:1744-50. [DOI: 10.1016/j.bios.2008.09.004] [Citation(s) in RCA: 73] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2008] [Revised: 08/12/2008] [Accepted: 09/03/2008] [Indexed: 11/16/2022]
|
22
|
Lee KS, Lee HLT, Ram RJ. Polymer waveguide backplanes for optical sensor interfaces in microfluidics. LAB ON A CHIP 2007; 7:1539-1545. [PMID: 17960283 DOI: 10.1039/b709885p] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
A polymer optical backplane capable of generic luminescence detection within microfluidic chips is demonstrated using large core polymer waveguides and vertical couplers. The waveguides are fabricated through a new process combining mechanical machining and vapor polishing with elastomer microtransfer molding. A backplane approach enables general optical integration with planar array microfluidics since optical backplanes can be independently designed but still integrated with planar fluidic circuits. Fabricated large core waveguides exhibit a loss of 0.1 dB cm(-1) at 626 nm, a measured numerical aperture of 0.50, and a collection efficiency of 2.86% in an n = 1.459 medium, comparable to a 0.50 NA microscope objective. In addition to vertical couplers for out-of-plane collection and excitation, polymer waveguides are doped with organic dyes to provide wavelength selective filtering within waveguides, further improving optical device integration. With large core low loss waveguides, luminescence collection is improved and measurements can be performed with simple LEDs and photodetectors. Fluorescein detection via fluorescence intensity with a limit of detection (3sigma) of 200 nM in a 1 microL volume is demonstrated. Phosphorescence lifetime based oxygen detection in water in an oxygen controllable microbial cell culture chip with a limit of detection (3sigma) of 0.08% or 35 ppb is also demonstrated utilizing the waveguide backplane. Single waveguide luminescence collection performance is equivalent to a back collection geometry fiber bundle consisting of nine 500 microm diameter collection fibers.
Collapse
Affiliation(s)
- Kevin S Lee
- MIT, EECS, 32 Vassar St. 26-459, Cambridge, MA 02139, USA.
| | | | | |
Collapse
|