1
|
Lee SS, Nagar S, Rajagopalan L, Orilla W, Csaky KG, Almazan A, Yang L, Robinson MR. Using a Novel, Subconjunctival, Sustained-Release Mitomycin C Formulation in a Rabbit Model of Filtration Surgery with Gel Stent Implantation. J Ocul Pharmacol Ther 2024; 40:297-308. [PMID: 38687355 PMCID: PMC11296147 DOI: 10.1089/jop.2023.0100] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Accepted: 02/28/2024] [Indexed: 05/02/2024] Open
Abstract
Purpose: To investigate gel stent implantation with and without intraoperative sustained-release mitomycin C (MMC SR) in a rabbit model for gel stent implantation, and to examine aqueous humor outflow (AHO) postimplantation. Methods: Four groups of rabbits were included. Group 1 was untreated (control). Groups 2, 3, and 4 received the gel stent without MMC, with MMC solution (subconjunctival injection), and with MMC SR (subconjunctival injection), respectively. Intraocular pressure (IOP) and AHO were assessed via tonometry and indocyanine green-based angiography, respectively. The main efficacy measure was change in IOP from baseline. Results: Following gel stent implantation, Groups 2, 3, and 4 maintained ≥20% IOP reduction (response) for a median duration of 1 week, 6.5 weeks, and 30 weeks, respectively. Angiography showed normal aqueous humor drainage (Group 1) beginning at the perilimbal trabecular plexus and continuing posteriorly to episcleral outflow vessels. Following implantation, drainage occurred preferentially and directly into the subconjunctival bleb. Conclusions: Gel stent implantation with MMC SR was most effective in achieving sustained, long-term IOP reduction in the rabbit model, compared with implantation with or without MMC solution. Bleb presence and the postimplantation aqueous angiography results indicated redirection of the AHO to the subconjunctival vasculature and presumed lymphatics, suggesting efficient glaucoma filtration to lower IOP in this model. This rabbit model and aqueous angiography may help refine understanding of the mechanism of action of minimally invasive glaucoma surgeries and ultimately translate to improved surgical devices and procedures for patients with glaucoma.
Collapse
Affiliation(s)
- Susan S. Lee
- Allergan, an AbbVie company, Irvine, California, USA
| | - Saumya Nagar
- Allergan, an AbbVie company, Irvine, California, USA
| | | | | | - Karl G. Csaky
- Retina Foundation of the Southwest, Dallas, Texas, USA
| | | | - Liuqing Yang
- Allergan, an AbbVie company, Irvine, California, USA
| | | |
Collapse
|
2
|
Fang Z, Bi S, Brown JD, Chen J, Pan T. Microfluidics in the eye: a review of glaucoma implants from an engineering perspective. LAB ON A CHIP 2023; 23:4736-4772. [PMID: 37847237 DOI: 10.1039/d3lc00407d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2023]
Abstract
Glaucoma is a progressive optic neuropathy in the eye, which is a leading cause of irreversible blindness worldwide and currently affects over 70 million individuals. Clinically, intraocular pressure (IOP) reduction is the only proven treatment to halt the progression of glaucoma. Microfluidic devices such as glaucoma drainage devices (GDDs) and minimally invasive glaucoma surgery (MIGS) devices are routinely used by ophthalmologists to manage elevated IOP, by creating an artificial pathway for the over-accumulated aqueous humor (AH) in a glaucomatous eye, when the natural pathways are severely blocked. Herein, a detailed modelling and analysis of both the natural microfluidic pathways of the AH in the eye and artificial microfluidic pathways formed additionally by the various glaucoma implants are conducted to provide an insight into the causes of the IOP abnormality and the improvement schemes of current implant designs. The mechanisms of representative glaucoma implants have been critically reviewed from the perspective of microfluidics, and we have categorized the current implants into four groups according to the targeted drainage sites of the AH, namely Schlemm's canal, suprachoroidal space, subconjunctival space, and ocular surface. In addition, we propose to divide the development and evolution of glaucoma implant designs into three technological waves, which include microtube (1st), microvalve (2nd) and microsystem (3rd). With the emerging trends of minimal invasiveness and artificial intelligence in the development of medical implants, we envision that a comprehensive glaucoma treatment microsystem is on the horizon, which is featured with active and wireless control of IOP, real-time continuous monitoring of IOP and aqueous rate, etc. The current review could potentially cast light on the unmatched needs, challenges, and future directions of the microfluidic structural and functional designs of glaucoma implants, which would enable an enhanced safety profile, reduced complications, increased efficacy of lowering IOP and reduced IOP fluctuations, closed-loop and on-demand control of IOP, etc.
Collapse
Affiliation(s)
- Zecong Fang
- Bionic Sensing and Intelligence Center (BSIC), Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China.
| | - Shuzhen Bi
- Center for Intelligent Medical Equipment and Devices (iMED), University of Science and Technology of China, Suzhou, Jiangsu, 215123, China
| | | | - Junyi Chen
- Department of Ophthalmology and Visual Science, Eye and ENT Hospital, Shanghai Medical College, Fudan University, Shanghai, 200031, China
- NHC Key Laboratory of Myopia, Chinese Academy of Medical Sciences, and Shanghai Key Laboratory of Visual Impairment and Restoration (Fudan University), Shanghai, 200031, China
| | - Tingrui Pan
- Bionic Sensing and Intelligence Center (BSIC), Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, 518055, China.
- Center for Intelligent Medical Equipment and Devices (iMED), University of Science and Technology of China, Suzhou, Jiangsu, 215123, China
- Department of Precision Machinery and Precision Instrumentation, University of Science and Technology of China, Hefei, Anhui, 230026, China
| |
Collapse
|
3
|
Chan PPM, Larson MD, Dickerson JE, Mercieca K, Koh VTC, Lim R, Leung EHY, Samuelson TW, Larsen CL, Harvey A, Töteberg-Harms M, Meier-Gibbons F, Shu-Wen Chan N, Sy JB, Mansouri K, Zhang X, Lam DSC. Minimally Invasive Glaucoma Surgery: Latest Developments and Future Challenges. Asia Pac J Ophthalmol (Phila) 2023; 12:537-564. [PMID: 38079242 DOI: 10.1097/apo.0000000000000646] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Accepted: 10/12/2023] [Indexed: 12/21/2023] Open
Abstract
The development of minimally invasive glaucoma surgeries (MIGSs) was intended to provide safe and modestly efficacious modalities for early intervention of mild-to-moderate glaucoma, with minimal trauma and rapid recovery. They were mainly ab interno procedures that reduce intraocular pressure by facilitating the aqueous outflow by bypassing the trabecular meshwork resistance, reinforcing the uveoscleral flow via the supraciliary space, and reducing aqueous production by the ciliary body. While the cumulating evidence helps shape the role of the available MIGS, the exponential new development and advancement in this field has expanded the territory of MIGS. Apart from developing subconjunctival MIGS filtration devices (Xen gel stent and PRESERFLO MicroShunt), there is a tendency to revisit the "traditional" MIGS for alternative use and to modify the procedures with consideration of the fundamental aqueous outflow physiology. Combined MIGS has also been suggested, based on the theory that their different mechanisms may provide additive or synergistic effects. The advancement of laser procedures is also promising and could supplement unmet needs along the glaucoma treatment algorithm. This review examines the broad array of MIGS, updates the recent findings, discusses their potential alternative applications, and explores future challenges.
Collapse
Affiliation(s)
- Poemen P M Chan
- Department of Ophthalmology and Visual Sciences, The Chinese University of Hong Kong, Hong Kong, China
- Department of Ophthalmology and Visual Sciences, Lam Kin Chung. Jet King-Shing Ho Glaucoma Treatment and Research Centre, The Chinese University of Hong Kong, Hong Kong, China
| | | | - Jaime E Dickerson
- Sight Sciences, Menlo Park, CA, USA
- University of North Texas Health Science Center, North Texas Eye Research Institute, Fort Worth, TX, USA
| | | | - Victor Teck Chang Koh
- Department of Ophthalmology, National University Health System, Singapore
- Centre for Innovation and Precision Eye Health, Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| | - Ridia Lim
- Department of Ophthalmology, Sydney Eye Hospital, Sydney, Australia
- Save Sight Institute, Sydney Medical School, The University of Sydney, Sydney, Australia
| | - Enne Hiu Ying Leung
- The C-MER Dennis Lam & Partners Eye Center, C-MER International Eye Care Group, Hong Kong, China
| | - Thomas W Samuelson
- Minnesota Eye Consultants, Bloomington, MN, US
- Department of Ophthalmology, University of Minnesota, MN, US
| | - Christine L Larsen
- Minnesota Eye Consultants, Bloomington, MN, US
- Department of Ophthalmology, University of Minnesota, MN, US
| | | | - Marc Töteberg-Harms
- Department of Ophthalmology, Augusta University, Medical College of Georgia, Augusta, GA, USA
| | | | | | - Jessica Belle Sy
- Department of Ophthalmology, Sydney Eye Hospital, Sydney, Australia
- Baguio General Hospital and Medical Center, Baguil City, Benguet, Philippines
| | - Kaweh Mansouri
- Glaucoma Center, Swiss Visio, Clinique de Montchoisi, Lausanne, Switzerland
| | - Xiulan Zhang
- State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - Dennis S C Lam
- The C-MER Dennis Lam & Partners Eye Center, C-MER International Eye Care Group, Hong Kong, China
- The International Eye Research Institute of The Chinese University of Hong Kong (Shenzhen), Shenzhen, China
| |
Collapse
|
4
|
Sheybani A, Vera V, Grover DS, Vold SD, Cotter F, Bedrood S, Sawhney G, Piette SD, Simonyi S, Gu X, Balaram M, Gallardo MJ. Gel Stent Versus Trabeculectomy: The Randomized, Multicenter, Gold-Standard Pathway Study (GPS) of Effectiveness and Safety at 12 Months. Am J Ophthalmol 2023; 252:306-325. [PMID: 36972738 DOI: 10.1016/j.ajo.2023.03.026] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 03/16/2023] [Accepted: 03/18/2023] [Indexed: 03/28/2023]
Abstract
PURPOSE To compare effectiveness and safety of the gel stent to trabeculectomy in open-angle glaucoma (OAG). DESIGN Prospective, randomized, multicenter, noninferiority study. METHODS Patients with OAG and intraocular pressure (IOP) 15 to 44 mm Hg on topical IOP-lowering medication were randomized 2:1 to gel stent implantation or trabeculectomy. Primary end point (surgical success): percentage of patients at month 12 achieving ≥20% IOP reduction from baseline without medication increase, clinical hypotony, vision loss to counting fingers, or secondary surgical intervention (SSI) in a noninferiority test with 24% margins. Secondary end points (month 12) included mean IOP and medication count, postoperative intervention rate, visual recovery, and patient-reported outcomes (PROs). Safety end points included adverse events (AEs). RESULTS At month 12, the gel stent was statistically noninferior to trabeculectomy (between-treatment difference [Δ], -6.1%; 95% CI, -22.9%, 10.8%); 62.1% and 68.2% achieved the primary end point, respectively (P=.487); mean IOP and medication count reductions from baseline were significant (P<.001); and the IOP change-related Δ (2.8 mm Hg) favored trabeculectomy (P=.024). The gel stent resulted in fewer eyes requiring in-office postoperative interventions (P=.024 after excluding laser suture lysis), faster visual recovery (P≤.048), and greater 6-month improvements in visual function problems (ie, PROs; P≤.022). The most common AEs were reduced visual acuity at any time (gel stent, 38.9%; trabeculectomy, 54.5%) and hypotony (IOP <6 mm Hg at any time) (gel stent, 23.2%; trabeculectomy, 50.0%). CONCLUSIONS At month 12, the gel stent was statistically noninferior to trabeculectomy, per the percentage of patients achieving ≥20% IOP reduction from baseline without medication increase, clinical hypotony, vision loss to counting fingers, or SSI. Trabeculectomy achieved a statistically lower mean IOP, numerically lower failure rate, and numerically lower need for supplemental medications. The gel stent resulted in fewer postoperative interventions, better visual recovery, and fewer AEs.
Collapse
Affiliation(s)
- Arsham Sheybani
- Washington University School of Medicine (A.S.), St Louis, Missouri, USA.
| | - Vanessa Vera
- Allergan, an AbbVie company (V.V.), Irvine, California, USA
| | | | | | - Frank Cotter
- Vistar Eye Center (F.C.), Roanoke, Virginia, USA
| | - Sahar Bedrood
- Acuity Eye Group (S.B.), Arcadia, California, USA; Advanced Vision Care (S.B.), Los Angeles, California, USA
| | | | | | | | - Xuemin Gu
- AbbVie (X.G.), Madison, New Jersey, USA
| | - Mini Balaram
- Nethra Consulting LLC (M.B.), Princeton, New Jersey, USA
| | | |
Collapse
|
5
|
Betzler BK, Lim SY, Lim BA, Yip VCH, Ang BCH. Complications and post-operative interventions in XEN45 gel stent implantation in the treatment of open angle glaucoma-a systematic review and meta-analysis. Eye (Lond) 2023; 37:1047-1060. [PMID: 35347294 PMCID: PMC10101986 DOI: 10.1038/s41433-022-02022-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Revised: 01/31/2022] [Accepted: 03/10/2022] [Indexed: 11/09/2022] Open
Abstract
BACKGROUND The XEN45 Gel Stent is a subconjunctival filtering device that has demonstrated promising efficacy. This meta-analysis quantitatively evaluates reported complications and interventions after XEN45 implantation in the treatment of open angle glaucoma (OAG). METHODS Pilot, cohort, observational studies, and randomised controlled trials that included at least ten patients undergoing ab interno or externo XEN45 surgery, with or without phacoemulsification were deemed eligible for inclusion. A meta-analysis of proportions with random-effect models was performed using the meta routine in R version 3.2.1. Outcomes included the rate of complications and post-operative interventions. RESULTS One hundred and fifty-two studies were identified on initial literature search and 33 were included in final analysis. Numerical hypotony was the most common post-operative complication, involving 20% of patients (95% CI: 10-31%). Post-operative gross hyphema occurred in 14% (95% CI: 7-22%) and transient intra-ocular pressure (IOP) spikes (>30 mmHg) in 13% (95% CI: 4-27%). Stent exposure occurred in 1% (95% CI: 0-2%). Stent migration occurred in 1% (95% CI: 0-3%). XEN45 revision and/or a second XEN45 implantation was performed in 5% of patients (95% CI: 3-7%). Stent relocation was performed in 3% (95% CI: 1-7%). A second glaucoma procedure was performed in 11% (95% CI: 8-15%). 26% underwent one (95% CI: 17-36%), 13% underwent two (95% CI: 5-24%) while 4% underwent three (95% CI: 2-6%) bleb needling procedures. 35% of patients (95% CI: 29-40%) required at least one needling. The average rate of needling per patient was 0.38 (95% CI: 0.20-0.59). However, there is a lack of high-quality data, with 8 of the 33 studies assessed to have a moderate to high risk of bias. CONCLUSIONS While literature suggests that XEN45 Gel Stent implantation is safe in the treatment of OAG, the overall current level of evidence is low and further studies are needed. More than a third of patients require at least one post-operative bleb needling procedure.
Collapse
Affiliation(s)
- Bjorn Kaijun Betzler
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Sheng Yang Lim
- Army Medical Services, Singapore Armed Forces, Singapore, Singapore
| | - Boon Ang Lim
- Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute, Singapore, Singapore
| | - Vivien Cherng Hui Yip
- Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute, Singapore, Singapore
| | - Bryan Chin Hou Ang
- Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute, Singapore, Singapore.
- Department of Ophthalmology, Woodlands Health Campus, National Healthcare Group Eye Institute, Singapore, Singapore.
| |
Collapse
|
6
|
Panarelli JF, Vera V, Sheybani A, Radcliffe N, Fiscella R, Francis BA, Smith OU, Noecker RJ. Intraocular Pressure and Medication Changes Associated with Xen Gel Stent: A Systematic Review of the Literature. Clin Ophthalmol 2023; 17:25-46. [PMID: 36660309 PMCID: PMC9845068 DOI: 10.2147/opth.s390955] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Accepted: 12/19/2022] [Indexed: 01/06/2023] Open
Abstract
The Xen gel stent (Allergan Inc, an AbbVie company; Dublin, Ireland) was conceived as an option for patients requiring modest IOP reduction but for whom trabeculectomy was not yet indicated. As with any glaucoma surgery, establishing criteria for patient selection and identifying factors that contribute to a high likelihood of success are important. To help guide clinical decision-making, a systematic review of published studies on the gel stent was performed, with the goal of understanding postoperative outcomes based on clinical and patient factors. Results were organized around a series of pertinent clinical questions based on scenarios encountered in clinical practice. Criteria for including studies were intentionally broad, with the objective of simulating the diverse population of glaucoma patients encountered in real-world practice. Outcomes for IOP and medication reduction postoperatively were assessed in various analyses, including in eyes with various glaucoma types and severity; in eyes naïve to surgery as well as those with a history of prior incisional glaucoma surgery; and when surgery was performed as a standalone procedure or at the time of cataract surgery. The results of each of the various analyses were consistent in demonstrating that successful gel stent surgery achieved a postoperative IOP of approximately 14.0 mm Hg and reduction to fewer than 1 glaucoma medication. Additional data are shown on outcomes by method of implant (ab interno vs ab externo); intraoperative use of antifibrotics; and rates of needling in published studies.
Collapse
Affiliation(s)
- Joseph F Panarelli
- Department of Ophthalmology, New York University, New York, NY, USA,Correspondence: Joseph F Panarelli, Department of Ophthalmology, New York University, 222 E 41st St, 3rd Floor, New York, NY, 10017, USA, Email
| | | | - Arsham Sheybani
- Department of Ophthalmology and Visual Sciences, Washington University in St. Louis School of Medicine, St. Louis, MO, USA
| | - Nathan Radcliffe
- Department of Ophthalmology, New York Eye and Ear Infirmary, New York, NY, USA
| | | | - Brian A Francis
- Department of Ophthalmology, Doheny Eye Institute, University of California Los Angeles, Los Angeles, CA, USA
| | | | - Robert J Noecker
- Department of Ophthalmology and Visual Science, Yale School of Medicine, New Haven, CT, USA,Ophthalmic Consultants of Connecticut, Fairfield, CT, USA
| |
Collapse
|
7
|
Yang X, Zhao Y, Zhong Y, Duan X. The efficacy of XEN gel stent implantation in glaucoma: a systematic review and meta-analysis. BMC Ophthalmol 2022; 22:305. [PMID: 35836197 PMCID: PMC9284889 DOI: 10.1186/s12886-022-02502-y] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2022] [Accepted: 06/16/2022] [Indexed: 01/10/2023] Open
Abstract
Background Xen is a device for minimally invasive glaucoma surgery, and is used to treat POAG, pseudoexfoliative or pigmentary glaucoma, as well as refractory glaucoma. The efficacy of XEN in treating glaucoma remains to be confirmed and clarified. Hence, we conducted a systematic review and meta-analysis to examine the efficacy and associated complication of XEN implantations. Methods We conducted a literature search in PubMed, EMBASE, the Cochrane Library of Systematic Reviews, Web of Science, China National Knowledge Infrastructure, WanFang and SinoMed databases to identify studies, published before May 15, 2021, which evaluated XEN in glaucoma, and parameters for measurements included intra-ocular pressure (IOP), number of anti-glaucoma medications (NOAM), and bleb needling rate. We compared the measurements of XEN-only procedure between phaco-XEN and trabeculectomy, and we also did sub-analysis based on time points, glaucoma types, ethnics, etc. Sensitivity analyses and publication bias were conducted for evaluating bias.This study followed the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA 2020) reporting guideline. Results We identified 78 eligible studies, analysis revealed obvious IOP reduction after XEN stent implantation (SMD: 1.69, 95% CI 1.52 to 1.86, p value < 0.001) and NOAM reduction (SMD: 2.11, 95% CI 1.84 to 2.38, p value < 0.001). Sub-analysis showed no significant difference with respect to time points, ethnicities, and economic status. No significant difference was found between XEN treatment effect on POAG and PEXG eyes and between pseudo-phakic and phakic eyes. Also no significant difference was found between XEN and phaco-XEN surgery in terms of IOP after surgery (SMD: -0.01, 95% CI -0.09 to 0.08, p value 0.894). However, NOAM (after publication bias correction) and bleb needling rate (RR: 1.45, 95% CI 1.06to 1.99, p value 0.019) were lower in phaco-XEN group compared to XEN only group. Compared to trabeculectomy, XEN implantation had similar after-surgery IOP, however bleb needling rate (RR: 2.42, 95% CI 1.33 to 4.43, p value 0.004) was higher. Conclusion Our results confirmed that XEN is effective in lowering both IOP and NOAM till 48 months after surgery. It is noteworthy that XEN implantation leads to higher needling rate, compared to phaco-XEN or trabeculectomy. Further research, studying complications of XEN on non-European ethnicities, especially on Asian, are in urgent need before XEN is widely applied. Supplementary Information The online version contains supplementary material available at 10.1186/s12886-022-02502-y.
Collapse
Affiliation(s)
- Xiang Yang
- Changsha Aier Eye Hospital, Changsha, Hunan, China
| | - Yang Zhao
- Changsha Aier Eye Hospital, Changsha, Hunan, China
| | - Yu Zhong
- Changsha Aier Eye Hospital, Changsha, Hunan, China.,Aier School of Ophthalmology, Central South University, Changsha, Hunan, China
| | - Xuanchu Duan
- Changsha Aier Eye Hospital, Changsha, Hunan, China. .,Aier School of Ophthalmology, Central South University, Changsha, Hunan, China.
| |
Collapse
|
8
|
Pereira ICF, van de Wijdeven R, Wyss HM, Beckers HJM, den Toonder JMJ. Conventional glaucoma implants and the new MIGS devices: a comprehensive review of current options and future directions. Eye (Lond) 2021; 35:3202-3221. [PMID: 34127842 PMCID: PMC8602385 DOI: 10.1038/s41433-021-01595-x] [Citation(s) in RCA: 48] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2020] [Revised: 04/19/2021] [Accepted: 05/05/2021] [Indexed: 02/05/2023] Open
Abstract
Glaucoma is a progressive optic neuropathy that is the second leading cause of preventable blindness worldwide, after cataract formation. A rise in the intraocular pressure (IOP) is considered to be a major risk factor for glaucoma and is associated with an abnormal increase of resistance to aqueous humour outflow from the anterior chamber. Glaucoma drainage devices have been developed to provide an alternative pathway through which aqueous humour can effectively exit the anterior chamber, thereby reducing IOP. These devices include the traditional aqueous shunts with tube-plate design, as well as more recent implants, such as the trabeculectomy-modifying EX-PRESS® implant and the new minimally invasive glaucoma surgery (MIGS) devices. In this review, we will describe each implant in detail, focusing on their efficacy in reducing IOP and safety profile. Additionally, a critical and evidence-based comparison between these implants will be provided. Finally, we will propose potential developments that may help to improve the performance of current devices.
Collapse
Affiliation(s)
- Inês C. F. Pereira
- grid.6852.90000 0004 0398 8763Microsystems Research Section, Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands ,grid.6852.90000 0004 0398 8763Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Rosanne van de Wijdeven
- grid.6852.90000 0004 0398 8763Microsystems Research Section, Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands ,grid.6852.90000 0004 0398 8763Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Hans M. Wyss
- grid.6852.90000 0004 0398 8763Microsystems Research Section, Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands ,grid.6852.90000 0004 0398 8763Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Henny J. M. Beckers
- grid.412966.e0000 0004 0480 1382University Eye Clinic Maastricht, Maastricht University Medical Centre+ (MUMC+), Maastricht, The Netherlands
| | - Jaap M. J. den Toonder
- grid.6852.90000 0004 0398 8763Microsystems Research Section, Department of Mechanical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands ,grid.6852.90000 0004 0398 8763Institute for Complex Molecular Systems (ICMS), Eindhoven University of Technology, Eindhoven, The Netherlands
| |
Collapse
|
9
|
Gabbay IE, Goldberg M, Allen F, Lin Z, Morley C, Pearsall T, Muraleedharan V, Ruben S. Efficacy and safety data for the Ab interno XEN45 gel stent implant at 3 Years: A retrospective analysis. Eur J Ophthalmol 2021; 32:11206721211014381. [PMID: 33938304 DOI: 10.1177/11206721211014381] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
PURPOSE To report efficacy and safety measures of the XEN45 gel stent at 36 months in the UK National Health Service setting. METHODS Retrospective non-comparative audit of the records of patients who underwent XEN45 implantation between June 2015 and May 2017 was performed. Main outcome measures were intraocular pressure and number of antihypertensive medications used. Failure was defined as need for further surgery or stent removal. Success was defined as a 20% decrease in intraocular pressure without the need for additional glaucoma medications or a reduction in antihypertensive medications without an increase in baseline intraocular pressure. Needling rates and preoperative factors effect were assessed. RESULTS The cohort included 205 patients (205 eyes) with primary open angle glaucoma (84.4%), angle closure glaucoma (7.8%), or refractory glaucoma (7.8%), 62.9% had a stand-alone procedure and 37.1%, a combined phaco-XEN45 procedure. Mean intraocular pressure was 22.6 ± 7.0 mmHg at baseline compared to 14.7 ± 3.8 mmHg at 24 months and 14.0 ± 2.9 mmHg at 36 months (p < 0.001 for both). Mean number of medications used was 2.6 ± 1.1 at baseline compared to 0.5 ± 0.9 and 0.6 ± 1.0, at 24- and 36-months, respectively (p < 0.001 for both). The failure rate at 36 months was 25%. Needling was required in 36.6%. Evaluation of background factors yielded an increased failure rate in non-Caucasians compared to Caucasians (74% vs 21%, p < 0.001). CONCLUSION XEN45 implantation is effective and safe at 36 months' follow-up. Patients should be advised regarding the risk of failure and possible need for bleb revisions. Careful patient selection may be required.
Collapse
Affiliation(s)
- Itay E Gabbay
- Department of Ophthalmology, Mid and South Essex NHS Foundation Trust, Southend-on-Sea, UK
- Rabin Medical Center - Beilinson Hospital, Petach Tikva; affiliated to Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Mordechai Goldberg
- Department of Ophthalmology, Mid and South Essex NHS Foundation Trust, Southend-on-Sea, UK
| | - Felicity Allen
- Department of Ophthalmology, Mid and South Essex NHS Foundation Trust, Southend-on-Sea, UK
| | - Zhiheng Lin
- Department of Ophthalmology, Mid and South Essex NHS Foundation Trust, Southend-on-Sea, UK
| | - Christine Morley
- Department of Ophthalmology, Mid and South Essex NHS Foundation Trust, Southend-on-Sea, UK
| | - Tahmina Pearsall
- Whipps Cross University Hospital, Barts Health NHS Trust, London, UK
| | - Veena Muraleedharan
- Department of Ophthalmology, Mid and South Essex NHS Foundation Trust, Southend-on-Sea, UK
| | - Simon Ruben
- Department of Ophthalmology, Mid and South Essex NHS Foundation Trust, Southend-on-Sea, UK
| |
Collapse
|
10
|
Lim SY, Betzler BK, Yip LWL, Dorairaj S, Ang BCH. Standalone XEN45 Gel Stent implantation versus combined XEN45-phacoemulsification in the treatment of open angle glaucoma-a systematic review and meta-analysis. Graefes Arch Clin Exp Ophthalmol 2021; 259:3209-3219. [PMID: 33914156 DOI: 10.1007/s00417-021-05189-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2021] [Revised: 03/19/2021] [Accepted: 04/07/2021] [Indexed: 11/28/2022] Open
Abstract
PURPOSE The XEN45 Gel Stent is currently the only FDA-approved sub-conjunctival minimally invasive glaucoma surgery (MIGS) procedure. It has been used worldwide either as a standalone implantation procedure or in combination with phacoemulsification surgery. Concomitant phacoemulsification is understood to influence outcomes of traditional subconjunctival filtering surgery. However, the comparative efficacy between standalone XEN45 Gel Sent implantation ("Standalone XEN45") and combined XEN-phacoemulsification surgery ("XEN45-Phaco") remains unclear. This study aims to appraise current literature to compare the efficacy of Standalone XEN45 and XEN45-Phaco in open-angle glaucoma. METHODS A comprehensive search of PubMed, CINAHL, CENTRAL databases was performed with the terms "Xen surgery" followed by selective vetting. Pilot, cohort, observational studies and randomised controlled trials that included at least 10 patients undergoing either Standalone XEN45 or XEN45-Phaco surgeries for the treatment of open-angle glaucoma were deemed eligible for inclusion after independent assessment by 2 authors. The search workflow was reported according to the PRISMA guidelines. Data was pooled using random-effects model. A meta-analysis of continuous outcome and proportions was performed using the meta routine in R v3.2.1. RESULTS Ten studies were included. There was a statistically significant difference in IOP reduction favouring Standalone XEN45 at post-operative day 1, week 1, months 1, 3 and 6. There was a statistically significant difference in decrease in IOP-lowering medications favouring Standalone XEN45 at post-operative week 1 and month 1. CONCLUSION Standalone XEN45 has superior IOP-lowering outcomes compared to XEN45-Phaco in the early post-operative period, up to 6 months after surgery.
Collapse
Affiliation(s)
- Sheng Yang Lim
- Department of Ophthalmology, National University Hospital, National University Hospital Systems, 5 Lower Kent Ridge Road, Singapore, 119074, Singapore.
| | - Bjorn Kaijun Betzler
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Leonard Wei Leon Yip
- Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute, 11 Jln Tan Tock Seng, Singapore, 308433, Singapore
| | - Syril Dorairaj
- Department of Ophthalmology, Mayo Clinic, Rochester, USA
| | - Bryan Chin Hou Ang
- Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute, 11 Jln Tan Tock Seng, Singapore, 308433, Singapore.
- Department of Ophthalmology, Woodlands Health Campus, Singapore, Singapore.
| |
Collapse
|
11
|
Ventura-Abreu N, Dotti-Boada M, Muniesa-Royo MJ, Izquierdo-Serra J, González-Ventosa A, Millá E, Pazos M. XEN45 real-life evaluation: Survival analysis with bleb needling and major revision outcomes. Eur J Ophthalmol 2021; 32:11206721211012847. [PMID: 33908807 DOI: 10.1177/11206721211012847] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
PURPOSE To evaluate real-life outcomes of XEN45 stent surgery including bleb needling (BN) and surgical bleb revision (SBR). METHODS Retrospective analysis of all XEN45 gel stents implanted in a tertiary glaucoma center with a minimum follow-up of 6 months. The main outcomes were intraocular pressure (IOP), the number of glaucoma medications, postoperative maneuvers like BN, and subsequent SBR. Success was defined as IOP ⩽ 18 and 20% reduction (criterion A), ⩽15 and 25% reduction (criterion B), and ⩽12 mmHg and 30% reduction (criterion C) reached with (qualified) or without (complete) medications at the last visit. Complete failure was defined as additional glaucoma surgery, loss of light perception, or sight-threatening complications. Multivariable Cox regression and Kaplan-Meier survival estimates tests were performed. RESULTS Fifty-eight eyes with either stand-alone or combined Phaco-XEN surgery were included. Complete success by the different definitions was 50.0% (95% confidence interval, 5.8%-84.5%) (A), 50.0% (5.8%-84.5%) (B), and 25% (0.9%-66.5%) (C) whereas qualified success was 38.3% (1.6%-80.1%), 31.7% (2.0%-71.4%), and 0%, respectively, at the 24-months visit. 30% of cases underwent BN with 5-Fluorouracil, and SBR was performed in 17.5% of eyes. Low IOP levels at 1-month and early BN were significantly associated with success. The highest chance of failure was achieved in the combined Phaco-XEN group undergoing SBR. CONCLUSIONS In our real-life setting, the first month IOP was associated with greater success rates. Although BN obtained improved IOP values, SBR was associated with a greater bleb survival in the stand-alone XEN group. Both BN and SBR had poor outcomes in the combined Phaco-XEN group.
Collapse
Affiliation(s)
- Néstor Ventura-Abreu
- Ophthalmology Department, Hospital Clínic de Barcelona, University of Barcelona (UB), Barcelona, Spain
- PhD Program, Instituto de Investigaciones Oftalmológicas Ramón Castroviejo, Department of Immunology, Ophthalmology and ORL, Faculty of Medicine, Complutense University of Madrid (UCM), Madrid, Spain
| | - Marina Dotti-Boada
- Ophthalmology Department, Hospital Clínic de Barcelona, University of Barcelona (UB), Barcelona, Spain
| | - María Jesús Muniesa-Royo
- Ophthalmology Department, Hospital Clínic de Barcelona, University of Barcelona (UB), Barcelona, Spain
- Institut d'Investigacions Mèdiques August Pi i Sunyer (IDIBAPS), Barcelona, Spain
| | - Jordi Izquierdo-Serra
- Ophthalmology Department, Hospital Clínic de Barcelona, University of Barcelona (UB), Barcelona, Spain
| | - Andrea González-Ventosa
- Ophthalmology Department, Hospital Clínic de Barcelona, University of Barcelona (UB), Barcelona, Spain
| | - Elena Millá
- Ophthalmology Department, Hospital Clínic de Barcelona, University of Barcelona (UB), Barcelona, Spain
- Institut d'Investigacions Mèdiques August Pi i Sunyer (IDIBAPS), Barcelona, Spain
- Barcelona University, Barcelona, Spain
| | - Marta Pazos
- Ophthalmology Department, Hospital Clínic de Barcelona, University of Barcelona (UB), Barcelona, Spain
- Institut d'Investigacions Mèdiques August Pi i Sunyer (IDIBAPS), Barcelona, Spain
| |
Collapse
|
12
|
Poelman HJ, Pals J, Rostamzad P, Bramer WM, Wolfs RCW, Ramdas WD. Efficacy of the XEN-Implant in Glaucoma and a Meta-Analysis of the Literature. J Clin Med 2021; 10:jcm10051118. [PMID: 33800112 PMCID: PMC7962186 DOI: 10.3390/jcm10051118] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2021] [Revised: 02/27/2021] [Accepted: 03/01/2021] [Indexed: 12/12/2022] Open
Abstract
Background: To assess the efficacy of XEN-implant surgery in patients with glaucoma, and to perform a meta-analysis of previously published results and compare these to our data. Methods: Prospective case-control study, in which all eyes that underwent XEN-implant surgery were included from 2015 onwards. Sub-analyses were performed for eyes that underwent XEN-implant as standalone procedure and as cataract-combined procedure. To compare our results, a systematic review was performed using the Embase, PubMed, Web of Science, and Cochrane database. Meta-analyses were performed by combining data (intraocular pressure (IOP), IOP-lowering medication, and complications) from the retrieved studies. Results: A total of 221 eyes underwent XEN-implant surgery (124 standalone and 97 cataract-combined). The mean ± standard deviation IOP declined from 18.8 ± 6.5 to 13.5 ± 4.3 mmHg at the last follow-up (p < 0.001; 28.9%). Postoperative, no significant differences in IOP or IOP-lowering medication were found between patients with and without combined procedure. Secondary surgeries were performed in 20.8% of eyes, most of them (63.0%) within six months. A meta-analysis of 19 studies retrieved from the systematic review showed a two-years postoperative pooled mean (weighted mean difference) of 14.5 (7.3) mmHg and 1.0 (1.6) for IOP and IOP-lowering medications, respectively (compared to 13.5 (5.3) mmHg and 3.2 (2.4) in the current study). Conclusion: XEN-implant surgery was effective and safe in lowering IOP and the number of IOP-lowering medications. There were no differences between standalone and combined procedures.
Collapse
Affiliation(s)
- Huub J. Poelman
- Department of Ophthalmology, Erasmus MC, University Medical Center, 3000 CA Rotterdam, The Netherlands; (H.J.P.); (J.P.); (P.R.); (R.C.W.W.)
| | - Jan Pals
- Department of Ophthalmology, Erasmus MC, University Medical Center, 3000 CA Rotterdam, The Netherlands; (H.J.P.); (J.P.); (P.R.); (R.C.W.W.)
| | - Parinaz Rostamzad
- Department of Ophthalmology, Erasmus MC, University Medical Center, 3000 CA Rotterdam, The Netherlands; (H.J.P.); (J.P.); (P.R.); (R.C.W.W.)
| | - Wichor M. Bramer
- Medical Library, Erasmus MC, University Medical Center, 3000 CA Rotterdam, The Netherlands;
| | - Roger C. W. Wolfs
- Department of Ophthalmology, Erasmus MC, University Medical Center, 3000 CA Rotterdam, The Netherlands; (H.J.P.); (J.P.); (P.R.); (R.C.W.W.)
| | - Wishal D. Ramdas
- Department of Ophthalmology, Erasmus MC, University Medical Center, 3000 CA Rotterdam, The Netherlands; (H.J.P.); (J.P.); (P.R.); (R.C.W.W.)
- Correspondence: ; Tel.: +31-10-7033691
| |
Collapse
|
13
|
Results of fluorouracil-augmented Xen45 implantation in primary open-angle and pseudoexfoliation glaucoma. Int Ophthalmol 2020; 41:945-955. [PMID: 33180281 DOI: 10.1007/s10792-020-01650-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Accepted: 10/29/2020] [Indexed: 01/28/2023]
Abstract
PURPOSE To report the effectiveness and safety of 5-fluorouracil (5-FU)-augmented Xen45 implantation in primary open-angle glaucoma (POAG) and pseudoexfoliation glaucoma (PEXG). METHODS This single-center, retrospective chart review study included 29 eyes that underwent 5-FU-augmented Xen45 implantation. Main outcome measures were intraocular pressure (IOP) levels and number of glaucoma medications. Surgical success was defined as IOP ≤ 21 mmHg and ≥ 20% reduction from preoperative levels without (complete success) or with (qualified success) glaucoma medications and without further glaucoma surgery at last follow-up. All postoperative interventions and complications were also noted. RESULTS The mean age of the patients was 67.5 ± 10.3 years, and the mean follow-up time was 23.2 ± 12.6 months. Mean IOP was 24.5 ± 8.7 mmHg and decreased by 30.2% at 12 months, 24.9% at 24 months, and 31.7% at final visit (p < 0.001, p = 0.006, p > 0.001, respectively). Mean number of glaucoma medications decreased from 2.83 preoperatively to 0.71 at 12 months, 0.87 at 24 months, and 0.86 at final visit (p < 0.001). At final visit, the complete success rate was 48.3%, qualified success rate was 69%, and 62.1% of the eyes were free of glaucoma medications. Needling was performed in 7 eyes (24%). Adverse events included choroidal detachment in 5 eyes, hyphema in 2 eyes, and endophthalmitis in 1 eye. CONCLUSION 5-FU-augmented Xen45 implantation in POAG and PEXG patients provided safe and effective IOP lowering with significant reduction of glaucoma medications up to 3 years.
Collapse
|
14
|
Comparing Medium-Term Clinical Outcomes following XEN® 45 and XEN® 63 Device Implantation. J Ophthalmol 2020; 2020:4796548. [PMID: 32280523 PMCID: PMC7125472 DOI: 10.1155/2020/4796548] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2020] [Revised: 02/22/2020] [Accepted: 02/26/2020] [Indexed: 02/07/2023] Open
Abstract
Purpose To evaluate medium-term clinical outcomes with XEN® 45 or XEN® 63 Gel Stent (Allergan, Dublin, Ireland) for treatment of primary open angle glaucoma (POAG). Materials and Methods. Retrospective, descriptive, and observational study involving 40 patients implanted with a XEN® 45 Gel Stent and 34 implanted with a XEN® 63 Gel Stent who had undergone POAG surgery and had been followed up and controlled between 12 and 36 months. Results IOP dropped from 18.02 ± 5.23 mmHg preop to 13.81 ± 1.88, 14.80 ± 2.23, and 14.62 ± 1.90 at 1, 2, and 3 years after surgery (p < 0.001) consecutively with XEN® 45 and from 19.00 ± 6.11 mmHg preop to 15.47 ± 2.45, 14.66 ± 2.45, and 15.46 ± 2.48 at 1, 2, and 3 years after surgery (p < 0.001) with XEN® 63. The number of drugs used by patients to treat their glaucoma decreased after undergoing surgery in both groups. Within the XEN® 45 group, mean changes at 1 year, 2 years, and 3 years amounted to 70%, 74.3%, and 37.5%, respectively, whereas within the XEN® 63 group, the mean reduction was 75%, 79.8%, and 71.9%. When comparing the outcomes for two groups, the differences did not prove to be statistically significant. More than 90% of the procedures included in the study (using either gel-stent device) were completed without any noteworthy complications. Conclusion POAG surgical procedures with either XEN® 45 or XEN® 63 Gel Stent implantation could be a safe and effective treatment approach.
Collapse
|